1
|
Correia JJ, Stafford WF, Erlandsen H, Cole JL, Premathilaka SH, Isailovic D, Dignam JD. Hydrodynamic and thermodynamic analysis of PEGylated human serum albumin. Biophys J 2024; 123:2506-2521. [PMID: 38898654 PMCID: PMC11365110 DOI: 10.1016/j.bpj.2024.06.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 05/31/2024] [Accepted: 06/17/2024] [Indexed: 06/21/2024] Open
Abstract
Covalent labeling of therapeutic drugs and proteins with polyethylene glycol (PEGylation) is an important modification for improving stability, solubility, and half-life. PEGylation alters protein solution behavior through its impact on thermodynamic nonideality by increasing the excluded volume, and on hydrodynamic nonideality by increasing the frictional drag. To understand PEGylation's impact, we investigated the thermodynamic and hydrodynamic properties of a model system consisting of PEGylated human serum albumin derivatives using analytical ultracentrifugation (AUC) and dynamic light scattering (DLS). We constructed PEGylated human serum albumin derivatives of single, linear 5K, 10K, 20K, and 40K PEG chains and a single branched-chain PEG of 40K (2 × 20K). Sedimentation velocity (SV) experiments were analyzed using SEDANAL direct boundary fitting to extract ideal sedimentation coefficients so, hydrodynamic nonideality ks, and thermodynamic nonideality 2BM1SV terms. These quantities allow the determination of the Stokes radius Rs, the frictional ratio f/fo, and the swollen or entrained volume Vs/v, which measure size, shape, and solvent interaction. We performed sedimentation equilibrium experiments to obtain independent measurements of thermodynamic nonideality 2BM1SE. From DLS measurements, we determined the interaction parameter, kD, the concentration dependence of the apparent diffusion coefficient, D, and from extrapolation of D to c = 0 a second estimate of Rs. Rs values derived from SV and DLS measurements and ensemble model calculations (see complementary study) are then used to show that ks + kD = theoretical 2B22M1. In contrast, experimental BM1 values from SV and sedimentation equilibrium data collectively allow for similar analysis for protein-PEG conjugates and show that ks + kD = 1.02-1.07∗BM1, rather than the widely used ks + kD = 2BM1 developed for hard spheres. The random coil behavior of PEG dominates the colloidal properties of PEG-protein conjugates and exceeds the sum of a random coil and hard-sphere volume due to excess entrained water.
Collapse
Affiliation(s)
- John J Correia
- Department of Cell & Molecular Biology, University of Miss Medical Center, Jackson, Mississippi.
| | - Walter F Stafford
- Department of Systems Biology, Harvard Medical School, Boston, Massachusetts
| | - Heidi Erlandsen
- Center for Open Research Resources and Equipment, University of Connecticut, Storrs, Connecticut
| | - James L Cole
- Department of Molecular and Cell Biology, University of Connecticut, Storrs, Connecticut
| | | | - Dragan Isailovic
- Department of Chemistry and Biochemistry, University of Toledo, Toledo, Ohio
| | - John David Dignam
- Department of Chemistry and Biochemistry, University of Toledo, Toledo, Ohio
| |
Collapse
|
2
|
Jani VP, Jani VP, Munoz C, Cabrales P. A mathematical model of tissue axial and radial diffusion in the microvasculature for intravascular microscopy and phosphorescence quenching data. Comput Biol Med 2024; 174:108406. [PMID: 38603898 DOI: 10.1016/j.compbiomed.2024.108406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 02/28/2024] [Accepted: 04/01/2024] [Indexed: 04/13/2024]
Abstract
This study aims to extend earlier Krogh Cylinder Models of an oxygen profile by considering axial diffusion and analytically solving Fick's Law Partial Differential Equation with novel boundary conditions via the separation of variables. We next prospectively collected a total of 20 animals, which were randomly assigned to receive either fresh or two-week-old stored red blood cell (RBC) transfusions and PQM oxygen data were measured acutely (90 min) or chronically (24 h). Transfusion effects were evaluated in vivo using intravital microscopy of the dorsal skinfold window chamber in Golden Syrian Hamsters. Hamsters were initially hemorrhaged by 50% of total blood volume and resuscitated 1-h post hemorrhage. PQM data were subsequently collected and fit the derived 2D Krogh cylinder model. Systemic hemodynamics (mean arterial pressure, heart rate) were similar in both pre and post-transfusion with either stored or fresh cells. Transfusion with stored cells was found to impair axial and radial oxygen gradients as quantified by our model and consistent with previous studies. Specifically, we observed a statistically significant decrease in the arteriolar tissue radial oxygen gradient after transfusion with stored RBCs at 24 h compared with fresh RBCs (0.33 ± 0.17 mmHg μ m-1 vs, 0.14 ± 0.12 mmHg μ m-1; p = 0.0280). We also observed a deficit in the arteriolar tissue oxygen gradient (0.03 ± 0.01 mmHg μ m-1 fresh vs. 0.018 ± 0.007 mmHg μ m-1 stored; p = 0.0185). We successfully derived and validated an analytical 2D Krogh cylinder model in an animal model of microhemodynamic oxygen diffusion aberration secondary to storage lesions.
Collapse
Affiliation(s)
- Vinay P Jani
- Department of Bioengineering, University of California, San Diego, La Jolla, CA, 92093-0412, USA
| | - Vivek P Jani
- Division of Cardiology, Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD, 21205, USA
| | - Carlos Munoz
- Department of Bioengineering, University of California, San Diego, La Jolla, CA, 92093-0412, USA
| | - Pedro Cabrales
- Department of Bioengineering, University of California, San Diego, La Jolla, CA, 92093-0412, USA.
| |
Collapse
|
3
|
Meng F, Kaul D, Thangaswamy S, Bhutoria S, Gerfen G, Branch C, Intaglietta M, Acharya SA. Semisynthetic supra plasma expanders: a new class of therapeutics to improve microcircualtion in sickle cell anaemia. ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY 2019; 47:73-82. [DOI: 10.1080/21691401.2018.1543194] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
- Fantao Meng
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
- Laboratory of Biochemistry and Vascular Biology, Center for Biologics Evaluation and Research, Food and Drug Administration, Silver Spring, MA, USA
| | - Dhananjaya Kaul
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
| | | | - Savita Bhutoria
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Gary Gerfen
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Craig Branch
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY, USA
- Department of Radiology, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Marcos Intaglietta
- Department of Bioengineering, University of California, San Diego, CA, USA
| | - Seetharama A. Acharya
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY, USA
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY, USA
| |
Collapse
|
4
|
|
5
|
Replacing the Transfusion of 1-2 Units of Blood with Plasma Expanders that Increase Oxygen Delivery Capacity: Evidence from Experimental Studies. J Funct Biomater 2014; 5:232-45. [PMID: 25350267 PMCID: PMC4285404 DOI: 10.3390/jfb5040232] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 09/17/2014] [Accepted: 10/15/2014] [Indexed: 12/14/2022] Open
Abstract
At least a third of the blood supply in the world is used to transfuse 1–2 units of packed red blood cells for each intervention and most clinical trials of blood substitutes have been carried out at this level of oxygen carrying capacity (OCC) restoration. However, the increase of oxygenation achieved is marginal or none at all for molecular hemoglobin (Hb) products, due to their lingering vasoactivity. This has provided the impetus for the development of “oxygen therapeutics” using Hb-based molecules that have high oxygen affinity and target delivery of oxygen to anoxic areas. However it is still unclear how these oxygen carriers counteract or mitigate the functional effects of anemia due to obstruction, vasoconstriction and under-perfusion. Indeed, they are administered as a low dosage/low volume therapeutic Hb (subsequently further diluted in the circulatory pool) and hence induce extremely small OCC changes. Hyperviscous plasma expanders provide an alternative to oxygen therapeutics by increasing the oxygen delivery capacity (ODC); in anemia they induce supra-perfusion and increase tissue perfusion (flow) by as much as 50%. Polyethylene glycol conjugate albumin (PEG-Alb) accomplishes this by enhancing the shear thinning behavior of diluted blood, which increases microvascular endothelial shear stress, causes vasodilation and lowering peripheral vascular resistance thus facilitating cardiac function. Induction of supra-perfusion takes advantage of the fact that ODC is the product of OCC and blood flow and hence can be maintained by increasing either or both. Animal studies suggest that this approach may save a considerable fraction of the blood supply. It has an additional benefit of enhancing tissue clearance of toxic metabolites.
Collapse
|
6
|
Abstract
The development of oxygen (O2)-carrying blood substitutes has evolved from the goal of replicating blood O2 transport properties to that of preserving microvascular and organ function, reducing the inherent or potential toxicity of the material used to carry O2, and treating pathologies initiated by anemia and hypoxia. Furthermore, the emphasis has shifted from blood replacement fluid to "O2 therapeutics" that restore tissue oxygenation to specific tissues regions. This review covers the different alternatives, potential and limitations of hemoglobin-based O2 carriers (HBOCs) and perfluorocarbon-based O2 carriers (PFCOCs), with emphasis on the physiologic conditions disturbed in the situation that they will be used. It describes how concepts learned from plasma expanders without O2-carrying capacity can be applied to maintain O2 delivery and summarizes the microvascular responses due to HBOCs and PFCOCs. This review also presents alternative applications of HBOCs and PFCOCs namely: 1) How HBOC O2 affinity can be engineered to target O2 delivery to hypoxic tissues; and 2) How the high gas solubility of PFCOCs provides new opportunities for carrying, dissolving, and delivering gases with biological activity. It is concluded that the development of current blood substitutes has amplified their applications horizon by devising therapeutic functions for O2 carriers requiring limited O2 delivery capacity restoration. Conversely, full, blood-like O2-carrying capacity reestablishment awaits the control of O2 carrier toxicity.
Collapse
Affiliation(s)
- Pedro Cabrales
- Department of Bioengineering, University of California, San Diego, La Jolla, California 92093-0412, USA.
| | | |
Collapse
|
7
|
Roche CJ, Cassera MB, Dantsker D, Hirsch RE, Friedman JM. Generating S-nitrosothiols from hemoglobin: mechanisms, conformational dependence, and physiological relevance. J Biol Chem 2013; 288:22408-25. [PMID: 23775069 DOI: 10.1074/jbc.m113.482679] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
In vitro, ferrous deoxy-hemes in hemoglobin (Hb) react with nitrite to generate nitric oxide (NO) through a nitrite reductase reaction. In vivo studies indicate Hb with nitrite can be a source of NO bioactivity. The nitrite reductase reaction does not appear to account fully for this activity because free NO is short lived especially within the red blood cell. Thus, the exporting of NO bioactivity both out of the RBC and over a large distance requires an additional mechanism. A nitrite anhydrase (NA) reaction in which N2O3, a potent S-nitrosating agent, is produced through the reaction of NO with ferric heme-bound nitrite has been proposed (Basu, S., Grubina, R., Huang, J., Conradie, J., Huang, Z., Jeffers, A., Jiang, A., He, X., Azarov, I., Seibert, R., Mehta, A., Patel, R., King, S. B., Hogg, N., Ghosh, A., Gladwin, M. T., and Kim-Shapiro, D. B. (2007) Nat. Chem. Biol. 3, 785-794) as a possible mechanism. Legitimate concerns, including physiological relevance and the nature of the mechanism, have been raised concerning the NA reaction. This study addresses these concerns demonstrating NO and nitrite with ferric hemes under near physiological conditions yield an intermediate having the properties of the purported NA heme-bound N2O3 intermediate. The results indicate that ferric heme sites, traditionally viewed as a source of potential toxicity, can be functionally significant, especially for partially oxygenated/partially met-R state Hb that arises from the NO dioxygenation reaction. In the presence of low levels of nitrite and either NO or a suitable reductant such as L-cysteine, these ferric heme sites can function as a generator for the formation of S-nitrosothiols such as S-nitrosoglutathione and, as such, should be considered as a source of RBC-derived and exportable bioactive NO.
Collapse
Affiliation(s)
- Camille J Roche
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, New York 10461, USA
| | | | | | | | | |
Collapse
|
8
|
Abstract
SIGNIFICANCE There has been a striking advancement in our understanding of red cell substitutes over the past decade. Although regulatory oversight has influenced many aspects of product development in this period, those who have approached the demonstration of efficacy of red cell substitutes have failed to understand their implication at the level of the microcirculation, where blood interacts closely with tissue. RECENT ADVANCES The understanding of the adverse effects of acellular hemoglobin (Hb)-based oxygen carriers (HBOCs) has fortunately expanded from Hb-induced renal toxicity to a more complete list of biochemical mechanism. In addition, various unexpected adverse reactions were seen in early clinical studies. The effects of the presence of acellular Hb in plasma are relatively unique because of the convergence of mechanical and biochemical natures. CRITICAL ISSUES Controlling the variables using genetic engineering and chemical modification to change specific characteristics of the Hb molecule may allow for solving the complex multivariate problems of acellular Hb vasoactivity. HBOCs may never be rendered free of negative effects; however, quantifying the nature and extent of microvascular complications establishes a platform for designing new ameliorative therapies. FUTURE DIRECTIONS It is time to leave behind the study of vasoactivity and toxicity based on bench-top measurements of biochemical changes and those based solely on systemic parameters in vivo, and move to a more holistic analysis of the mechanisms creating the problems, complemented with meaningful studies of efficacy.
Collapse
Affiliation(s)
- Pedro Cabrales
- Department of Bioengineering, University of California, San Diego, La Jolla, CA 92093, USA.
| |
Collapse
|
9
|
Chatpun S, Nacharaju P, Cabrales P. Improving cardiac function with new-generation plasma volume expanders. Am J Emerg Med 2012; 31:54-63. [PMID: 22867830 DOI: 10.1016/j.ajem.2012.05.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2012] [Revised: 05/24/2012] [Accepted: 05/25/2012] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Plasma expander (PE) based on polyethylene glycol (PEG) conjugated to albumin has shown positive results maintaining blood volume during hemodilution and restoring blood volume during resuscitation from hemorrhagic shock. Polyethylene glycol conjugation to human serum albumin (HSA), PEG-HSA, increases size, weight, and colloidal osmotic pressure, with minor effects on solution viscosity. METHODS This study was designed to test the hypothesis that PEG-HSA (2 g/dL) produced by direct PEGylation chemistry improves cardiac function during 2 experimental models, (i) moderate hemodilution and (ii) resuscitation from hemorrhagic shock, compared with a conventional colloidal PE (Dextran 70 kd [Dx70], 6 g/dL). Cardiac function was studied using a miniaturized pressure volume conductance catheter implanted in the left ventricle and evaluated in terms of cardiac indices derived from the pressure volume measurements. RESULTS Polyethylene glycol-HSA increased cardiac output, stroke volume, and stroke work and decreased systemic vascular resistance compared with Dx70 in both experimental models. The improvements induced by PEG-HSA in cardiac function were sustained over the observation time. Polyethylene glycol-HSA cardiac mechanoenergetics changes are the result of increased energy transferred per stroke and decreased resistance of the vasculature connecting the heart. In summary, PEG-HSA decreased left ventricle ejection impedance. CONCLUSION Ejection of blood diluted with PEG-HSA presented a reduced load to the heart, increased contractile function, and lowered the energy consumed per unit volume compared with Dx70. Our results emphasize the importance of heart function as a parameter to be included in the evaluation changes induced by new PEs.
Collapse
Affiliation(s)
- Surapong Chatpun
- Department of Bioengineering, University of California-San Diego, La Jolla, CA 92093, USA
| | | | | |
Collapse
|
10
|
PEG-albumin plasma expansion increases expression of MCP-1 evidencing increased circulatory wall shear stress: an experimental study. PLoS One 2012; 7:e39111. [PMID: 22720043 PMCID: PMC3375248 DOI: 10.1371/journal.pone.0039111] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2012] [Accepted: 05/16/2012] [Indexed: 11/19/2022] Open
Abstract
Treatment of blood loss with plasma expanders lowers blood viscosity, increasing cardiac output. However, increased flow velocity by conventional plasma expanders does not compensate for decreased viscosity in maintaining vessel wall shear stress (WSS), decreasing endothelial nitric oxide (NO) production. A new type of plasma expander using polyethylene glycol conjugate albumin (PEG-Alb) causes supra-perfusion when used in extreme hemodilution and is effective in treating hemorrhagic shock, although it is minimally viscogenic. An acute 40% hemodilution/exchange-transfusion protocol was used to compare 4% PEG-Alb to Ringer's lactate, Dextran 70 kDa and 6% Hetastarch (670 kDa) in unanesthetized CD-1 mice. Serum cytokine analysis showed that PEG-Alb elevates monocyte chemotactic protein-1 (MCP-1), a member of a small inducible gene family, as well as expression of MIP-1α, and MIP-2. MCP-1 is specific to increased WSS. Given the direct link between increased WSS and production of NO, the beneficial resuscitation effects due to PEG-Alb plasma expansion appear to be due to increased WSS through increased perfusion and blood flow rather than blood viscosity.
Collapse
|
11
|
Hightower CM, Salazar Vázquez BY, Cabrales P, Tsai AG, Acharya SA, Intaglietta M. Plasma expander and blood storage effects on capillary perfusion in transfusion after hemorrhage. Transfusion 2012; 53:49-59. [PMID: 22554380 DOI: 10.1111/j.1537-2995.2012.03679.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
BACKGROUND Treating hemorrhage with blood transfusions in subjects previously hemodiluted with different colloidal plasma expanders, using fresh autologous blood or blood that has been stored for 2 weeks, allows identifying the interaction between type of plasma expander and differences in blood storage. STUDY DESIGN AND METHODS Studies used the hamster window chamber model. Fresh autologous plasma, 130-kDa starch-based plasma expander (hydroxyethyl starch [HES]), or 4% polyethylene glycol-conjugated albumin (PEG-Alb) was used for 20% of blood volume (BV) hemodilution. Hemodilution was followed by a 55% by BV 40-minute hemorrhagic shock period, treated with transfusion of fresh or blood that was stored for 2 weeks. Outcome was evaluated 1 hour after blood transfusion in terms of microvascular and systemic variables. RESULTS Results were principally dependent on the type of colloidal solution used during hemodilution, 4% PEG-Alb yielding the best microvascular recovery evaluated in terms of the functional capillary density. This result was consistent whether fresh blood or stored blood was used in treating the subsequent shock period. Fresh blood results were significantly better in systemic and microvascular terms relative to stored blood. HES and fresh plasma hemodilution yielded less favorable results, a difference that was enhanced when fresh versus stored blood was compared in their efficacy of correcting the subsequent hemorrhage. CONCLUSION The type of plasma expander used for hemodilution influences the short-term outcome of subsequent volume resuscitation using blood transfusion, 4% PEG-Alb providing the most favorable outcome by comparison to HES or fresh plasma.
Collapse
Affiliation(s)
- C Makena Hightower
- Department of Bioengineering, University of California at San Diego, La Jolla, CA 92093-0412, USA
| | | | | | | | | | | |
Collapse
|
12
|
Sriram K, Tsai AG, Cabrales P, Meng F, Acharya SA, Tartakovsky DM, Intaglietta M. PEG-albumin supraplasma expansion is due to increased vessel wall shear stress induced by blood viscosity shear thinning. Am J Physiol Heart Circ Physiol 2012; 302:H2489-97. [PMID: 22505638 DOI: 10.1152/ajpheart.01090.2011] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We studied the extreme hemodilution to a hematocrit of 11% induced by three plasma expanders: polyethylene glycol (PEG)-conjugated albumin (PEG-Alb), 6% 70-kDa dextran, and 6% 500-kDa dextran. The experimental component of our study relied on microelectrodes and cardiac output to measure both the rheological properties of plasma-expander blood mixtures and nitric oxide (NO) bioavailability in vessel walls. The modeling component consisted of an analysis of the distribution of wall shear stress (WSS) in the microvessels. Our experiments demonstrated that plasma expansion with PEG-Alb caused a state of supraperfusion with cardiac output 40% above baseline, significantly increased NO vessel wall bioavailability, and lowered peripheral vascular resistance. We attributed this behavior to the shear thinning nature of blood and PEG-Alb mixtures. To substantiate this hypothesis, we developed a mathematical model of non-Newtonian blood flow in a vessel. Our model used the Quemada rheological constitutive relationship to express blood viscosity in terms of both hematocrit and shear rate. The model revealed that the net effect of the hemodilution induced by relatively low-viscosity shear thinning PEG-Alb plasma expanders is to reduce overall blood viscosity and to increase the WSS, thus intensifying endothelial NO production. These changes act synergistically, significantly increasing cardiac output and perfusion due to lowered overall peripheral vascular resistance.
Collapse
Affiliation(s)
- Krishna Sriram
- Department of Mechanical and Aerospace Engineering, University of California-San Diego, La Jolla, California 92093-0412, USA
| | | | | | | | | | | | | |
Collapse
|
13
|
Improved resuscitation from hemorrhagic shock with Ringer's lactate with increased viscosity in the hamster window chamber model. ACTA ACUST UNITED AC 2011; 71:418-24. [PMID: 21248647 DOI: 10.1097/ta.0b013e3181fa2630] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Infusion of large volume of fluid is practiced in the treatment of hemorrhagic shock although resuscitation with small fluid volumes reduces the risks associated with fluid overload. We explored the hypothesis that reduced Ringer's lactate (RL) volume restoration in hemorrhage is significantly improved by increasing its viscosity, leading to improved microvascular conditions. METHODS Awake hamsters were subjected to a hemorrhage of 50% of blood volume followed by a shock period of 1 hour. They were resuscitated with conventional RL (n = 6) or with RL whose viscosity was increased by the addition of 0.3% alginate (RL-HV) (n = 6). In both cases, the volume infused was 200% of shed blood. RESULTS After resuscitation, blood and plasma viscosities were 1.9 cp ± 0.18 cp and 1.0 cp ± 0.03 cp in RL and 2.5 cp ± 0.34 cp and 1.6 cp ± 0.05 cp in RL-HV. Mean arterial pressure was lower than baseline in RL. Arteriolar diameter and arteriolar and venular flow were significantly higher in RL-HV. Functional capillary density was significantly higher in RL-HV than RL. After 90 minutes of resuscitation, functional capillary density was lower than baseline in RL, whereas it was maintained in RL-HV. Arteriolar PO₂ was higher in RL-HV than RL. Microcirculation O₂ delivery and tissue PO₂ were significantly higher in RL-HV. CONCLUSIONS Increasing blood and plasma viscosities in resuscitation from hemorrhagic shock with increased viscosity RL improves microvascular hemodynamics and oxygenation parameters.
Collapse
|
14
|
Zhao C, Cheng X. Microfluidic separation of viruses from blood cells based on intrinsic transport processes. BIOMICROFLUIDICS 2011; 5:32004-3200410. [PMID: 22007267 PMCID: PMC3194787 DOI: 10.1063/1.3609262] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/23/2011] [Accepted: 06/19/2011] [Indexed: 05/07/2023]
Abstract
Clinical analysis of acute viral infection in blood requires the separation of viral particles from blood cells, since the cytoplasmic enzyme inhibits the subsequent viral detection. To facilitate this procedure in settings without access to a centrifuge, we present a microfluidic device to continuously purify bionanoparticles from cells based on their different intrinsic movements on the microscale. In this device, a biological sample is layered on top of a physiological buffer, and both fluids are transported horizontally at the same flow rate in a straight channel under laminar flow. While the micron sized particles such as cells sediment to the bottom layer with a predictable terminal velocity, the nanoparticles move vertically by diffusion. As their vertical travel distances have a different dependence on time, the micro- and nanoparticles can preferentially reside in the bottom and top layers respectively after certain residence time, yielding purified viruses. We first performed numerical analysis to predicate the particle separation and then tested the theory using suspensions of synthetic particles and biological samples. The experimental results using dilute synthetic particles closely matched the numerical analysis of a two layer flow system containing different sized particles. Similar purification was achieved using diluted blood spiked with human immunodeficiency virus. However, viral purification in whole blood is compromised due to extensive bioparticle collisions. With the parallelization and automation potential offered by microfluidics, this device has the potential to function as an upstream sample preparation module to continuously provide cell depleted bio-nanoparticles for downstream analysis.
Collapse
Affiliation(s)
- Chao Zhao
- Department of Materials Science and Engineering and Program of Bioengineering, Lehigh University, Bethlehem, Pennsylvania 18015, USA
| | | |
Collapse
|
15
|
Chatpun S, Cabrales P. Effects of plasma viscosity modulation on cardiac function during moderate hemodilution. Asian J Transfus Sci 2011; 4:102-8. [PMID: 20859509 PMCID: PMC2937285 DOI: 10.4103/0973-6247.67034] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Background Previous studies have found that increasing plasma viscosity as whole blood viscosity decrease has beneficial effects in microvascular hemodynamics. As the heart couples with systemic vascular network, changes in plasma and blood viscosity during hemodilution determine vascular pressure drop and flow rate, which influence cardiac function. This study aimed to investigate how changes in plasma viscosity affect on cardiac function during acute isovolemic hemodilution. Materials and Methods Plasma viscosity was modulated by hemodilution of 40% of blood volume with three different plasma expanders (PEs). Dextran 2000 kDa (Dx2M, 6.3 cP) and dextran 70 kDa (Dx70, 3.0 cP) were used as high and moderate viscogenic PEs, respectively. Polyethylene glycol conjugated with human serum albumin (PEG-HSA, 2.2 cP) was used as low viscogenic PE. The cardiac function was assessed using a miniaturized pressure-volume conductance catheter. Results After hemodilution, pressure dropped to 84%, 79%, and 78% of baseline for Dx2M, Dx70 and PEG-HSA, respectively. Cardiac output markedly increased for Dx2M and PEG-HSA. Dx2M significantly produced higher stroke work relative to baseline and compared to Dx70. Conclusion Acute hemodilution with PEG-HSA without increasing plasma viscosity provided beneficial effects on cardiac function compared to Dx70, and similar to those measured with Dx2M. Potentially negative effects of increasing peripheral vascular resistance due to the increase in plasma viscosity were prevented.
Collapse
Affiliation(s)
- Surapong Chatpun
- Department of Bioengineering, University of California, San Diego, La Jolla, CA, USA
| | | |
Collapse
|
16
|
Ananda K, Manjula BN, Meng F, Acharya VN, Intaglietta M, Acharya SA. Packing density of the PEG-shell in PEG-albumins: PEGylation induced viscosity and COP are inverse correlate of packing density. ACTA ACUST UNITED AC 2011; 40:14-27. [PMID: 21623695 DOI: 10.3109/10731199.2011.579568] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PEG-Alb represents a new class of low viscogenic plasma expanders that achieve super perfusion in vivo by mimicking the vasodilatory influence of high viscogenic plasma expanders. PEGylation-engineered structure of PEG albumin can be envisaged as a deformable molecular domain around the rigid central protein core. The correlation between the structure of PEG-shell in terms of packing of the PEG inside the PEG shell and PEGylation induced plasma expander (PE)-like properties of albumin has been investigated as a function of the number and length of the PEG-chain. The increase in molecular radius of albumin on PEGylation is non-linear as a function of the number of PEG chains conjugated. The packing density of PEG within the PEG-shell is an inverse correlate of PEG-chain size; i.e. the shorter chains pack more compactly than the longer ones. The PEGylation induced increase in the viscosity and COP of albumin is an exponential correlation of the number of ethylene oxide units (-CH(2)-CH(2)-O-) conjugated and is also a function of the PEG-chain length. At equivalence of PEG mass conjugated, the viscosity and COP of PEG-albumin adducts correlate inversely with packing density of PEG. All PEGylated albumins are not equivalent on the basis of total PEG mass conjugated. Accordingly, the structure of PEG albumin and its solution properties can be engineered to optimize a given total PEG mass for the application of PEG albumin as a resuscitation fluid. The extension arms minimize the influence of PEG shell on the structure of the protein core. We speculate that EAF-PEGylation is a preferable platform for PEGylation of protein therapeutics and is expected to generate products with better therapeutic efficacy.
Collapse
Affiliation(s)
- K Ananda
- Department of Medicine, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | | | | | | | | | | |
Collapse
|
17
|
|
18
|
Cabrales P, Meng F, Acharya SA. Tissue oxidative metabolism after extreme hemodilution with PEG-conjugated hemoglobin. J Appl Physiol (1985) 2010; 109:1852-9. [PMID: 20813980 DOI: 10.1152/japplphysiol.00344.2010] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
NADH-localized fluorometry was used as a noninvasive technique to monitor changes in the energy state of intact tissue (muscle and connective tissue), without anesthesia, as a function of blood plasma O(2)-carrying capacity in the hamster window chamber model. Acute moderate isovolemic hemodilution was induced by two isovolemic hemodilution steps: in the first step, 6% 70-kDa dextran (Dex70) was used to induce an acute anemic state (18% Hct); in the second step, exchange transfusion of polyethylene glycol (PEG) maleimide-conjugated Hb (4 g/dl, PEG-Hb) or Dex70 (6 g/dl) was used to reduce erythrocytes to 75% of baseline (11% Hct). PEG-Hb had six copies of PEG (5 kDa) conjugated to each human Hb (0.48 g PEG/g Hb) through extension arm-facilitated chemistry. Systemic parameters, microvascular perfusion, functional capillary density, intravascular and interstitial Po(2), and intracellular NADH fluorescence were monitored. Mean arterial blood pressure after extreme hemodilution was statistically significantly reduced for Dex70 compared with PEG-Hb. The presence of PEG-Hb in the circulation maintained positive acid-base balance. While microvascular blood flows were not different, functional capillary density was significantly higher for PEG-Hb than Dex70. Arteriolar Po(2) was higher in the presence of PEG-Hb than Dex70, but tissue and venular Po(2) were not different. Cellular energy metabolism (intracellular O(2)) in the tissues was improved with PEG-Hb. Moderate hemodilution to 18% Hct (6.4 g Hb/dl) brings tissue O(2) delivery to the verge of inadequacy. Extreme hemodilution to 11% Hct (3.7 g Hb/dl) produces tissue anoxia, and high-O(2)-affinity PEG-Hb (Po(2) at which blood is 50% saturated with O(2) = 4 Torr, 1.1 g Hb/dl) only partially decreases anaerobic metabolism without increasing tissue Po(2).
Collapse
Affiliation(s)
- Pedro Cabrales
- Department of Bioengineering, University of California, San Diego, 9500 Gilman Dr., La Jolla, CA 92093-0412, USA.
| | | | | |
Collapse
|
19
|
Roche CJ, Friedman JM. NO reactions with sol-gel and solution phase samples of the ferric nitrite derivative of HbA. Nitric Oxide 2009; 22:180-90. [PMID: 19919854 DOI: 10.1016/j.niox.2009.11.003] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2009] [Revised: 11/09/2009] [Accepted: 11/09/2009] [Indexed: 02/07/2023]
Abstract
The reaction of nitric oxide (NO) with the ferric (met) nitrite derivative of human adult hemoglobin Hb is probed for both solution phase and sol-gel encapsulated populations. The evolution of both the Q band absorption spectrum and fitted populations of Hb derivatives are used to show the sequence of events occurring when NO interacts with nitrite bound to a ferric heme in Hb. The sol-gel is used to compare the evolving populations as a function of quaternary state for the starting met-nitrite populations. The redox status of intermediates is probed using the CN(-) anion to trap ferric heme species. The emergent presence of reactive NO species such as N(2)O(3) during the course of the reaction is probed using the fluorescent probe DAF-2 whereas the fluorophore Chemifluor is used as an indirect measure of the ability of the reaction to create S-nitrosothiols on glutathione. The results are consistent with the formation of a stable reactive intermediate capable of generating bioactive forms of NO. The patterns observed are consistent with a proposed mechanism whereby NO reacts with the ferric nitrite derivative to generate N(2)O(3).
Collapse
Affiliation(s)
- Camille J Roche
- Department of Physiology and Biophysics, Albert Einstein College of Medicine, Bronx, NY 10461, USA
| | | |
Collapse
|
20
|
Sahu RK, Nacharaju P, Manjula BN, Acharya SA. Induced Plasma Expander-like Properties as a Function of PEG-chains on Extension Arm Facilitated PEGylation of Albumin: “Mushroom to Brush-Like” Conformational Transition of the PEG-albumin Conjugate. ACTA ACUST UNITED AC 2009; 37:245-56. [DOI: 10.3109/10731190903356438] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
21
|
Silverman TA, Weiskopf RB. Hemoglobin-based oxygen carriers: current status and future directions. Transfusion 2009; 49:2495-515. [DOI: 10.1111/j.1537-2995.2009.02356.x] [Citation(s) in RCA: 76] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
22
|
Goertz O, Kirschner MH, Lilienfein H, Babilas P, Steinau HU, Andree C, Daigeler A, Stachon A, Homann H, Langer S. Effects of maleimide-polyethylene glycol-modified human hemoglobin (MP4) on tissue necrosis in SKH1-hr hairless mice. Eur J Med Res 2009; 14:123-9. [PMID: 19380283 PMCID: PMC3352061 DOI: 10.1186/2047-783x-14-3-123] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
OBJECTIVE Tissue hypoxia after blood loss, replantation and flap reperfusion remains a challenging task in surgery. Normovolemic hemodilution improves hemorheologic properties without increasing oxygen carrying capacity. Red blood cell transfusion is the current standard of treatment with its attendant risks. The aim of this study was to investigate the potential of the chemically modified hemoglobin, MP4, to reduce skin flap necrosis and its effect on selected blood markers and kidneys. MATERIALS AND METHODS Tissue ischemia was induced in the ear of hairless mice (n=26). Hemodilution was performed by replacing one third of blood volume with the similar amount of MP4, dextran, or blood. The extent of non-perfused tissue was assessed by intravital fluorescent microscopy. RESULTS Of all groups, MP4 showed the smallest area of no perfusion (in percentage of the ear +/- SEM: 16.3% +/- 2.4), the control group the largest (22.4% +/- 3.5). Leukocytes showed a significant increase in the MP4 and dextran group (from 8.7 to 13.6 respectively 15.4*109/l). On histology no changes of the kidneys could be observed. CONCLUSION MP4 causes an increase of leukocytes, improves the oxygen supply of the tissue and shows no evidence of renal impairment.
Collapse
Affiliation(s)
- Ole Goertz
- Department of Plastic and Hand Surgery, Burn Center, Ruhr-University Bochum, Bochum, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
|
24
|
Cabrales P, Tsai AG, Ananda K, Acharya SA, Intaglietta M. Volume resuscitation from hemorrhagic shock with albumin and hexaPEGylated human serum albumin. Resuscitation 2008; 79:139-46. [PMID: 18621463 DOI: 10.1016/j.resuscitation.2008.04.020] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2008] [Revised: 04/21/2008] [Accepted: 04/28/2008] [Indexed: 11/29/2022]
Abstract
The effect of restoring intravascular volume with polyethylene glycol (PEG) conjugated to human serum albumin (PEG-Alb) on systemic parameters and microvascular hemodynamics after hemorrhagic shock resuscitation was studied in the hamster window chamber model. Moderate hemorrhagic shock was induced by controlled arterial bleeding of 50% of blood volume, and hypovolemia was maintained for 1h. Fluid resuscitation was accomplished by infusion of 25% of blood volume and recovery was followed over 90 min. The PEG-Alb (six chains of maleimide phenyl PEG conjugated human serum albumin at 4%) resuscitation group was compared human serum albumin (HSA) at 5% (HSA5) and 10% (HSA10) protein concentrations. Systemic parameters, microvascular perfusion and capillary perfusion (functional capillary density, FCD) were measured by noninvasive methods. Hyperoncotic solutions provided rapid restoration of blood pressure, blood gas parameters and microvascular perfusion. Systemic and microvascular recovery was best and most rapid with PEG-Alb and followed by HSA10 and HSA5. Only recovery with PEG-Alb was sustained beyond 90 min. Hemodynamic functional benefits of PEG-Alb and the potential disadvantages associated with HSA, suggest PEG-Alb as better resuscitation solution.
Collapse
Affiliation(s)
- Pedro Cabrales
- La Jolla Bioengineering Institute, La Jolla, CA 92037, USA.
| | | | | | | | | |
Collapse
|
25
|
Salazar Vázquez BY, Wettstein R, Cabrales P, Tsai AG, Intaglietta M. Microvascular experimental evidence on the relative significance of restoring oxygen carrying capacity vs. blood viscosity in shock resuscitation. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2008; 1784:1421-7. [PMID: 18502215 DOI: 10.1016/j.bbapap.2008.04.020] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2007] [Revised: 04/15/2008] [Accepted: 04/24/2008] [Indexed: 11/24/2022]
Abstract
The development of volume replacement fluids for resuscitation in hemorrhagic shock comprises oxygen carrying and non carrying fluids. Non oxygen carrying fluids or plasma expanders are used up to the transfusion trigger, and upon reaching this landmark either blood, and possibly in the near future oxygen carrying blood substitutes, are used. An experimental program in hemorrhagic shock using the hamster chamber window model allowed to compare the relative performance of most fluids proposed for shock resuscitation. This model allows investigating simultaneously the microcirculation and systemic reactions, in the awake condition, in a tissue isolated from the environment. Results from this program show that in general plasma expanders such as Ringer's lactate and dextran 70 kDa do not sufficiently restore blood viscosity upon reaching the transfusion trigger, causing microvascular collapse. This is in part restored by a blood transfusion, independently of the oxygen carrying capacity of red blood cells. These results lead to the proposal that effective blood substitutes must be designed to prevent microvascular collapse, manifested in the decrease of functional capillary density. Achievement of this goal, in combination with the increase of oxygen affinity, significantly postpones the need for a blood transfusion, and lowers the total requirement of restoration of intrinsic oxygen carrying capacity.
Collapse
Affiliation(s)
- Beatriz Y Salazar Vázquez
- Faculty of Medicine, Universidad Juárez del Estado de Durango, 34000 Victoria de Durango, Durango, Mexico
| | | | | | | | | |
Collapse
|
26
|
Survival time in severe hemorrhagic shock after perioperative hemodilution is longer with PEG-conjugated human serum albumin than with HES 130/0.4: a microvascular perspective. Crit Care 2008; 12:R54. [PMID: 18423033 PMCID: PMC2447609 DOI: 10.1186/cc6874] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2008] [Revised: 03/14/2008] [Accepted: 04/18/2008] [Indexed: 11/24/2022] Open
Abstract
Introduction Preoperative hemodilution is an established practice that is applied to reduce surgical blood loss. It has been proposed that polyethylene glycol (PEG) surface decorated proteins such as PEG-conjugated human serum albumin may be used as non-oxygen-carrying plasma expanders. The purpose of this study was to determine whether there is any difference in survival time after severe hemorrhagic shock following extreme hemodilution using a conventional hydroxyethyl starch (HES)-based plasma expander or PEG-albumin. Methods Experiments were performed using the hamster skinfold window preparation. Human serum albumin that was surface decorated with PEG was compared with Voluven 6% (Fresenius Kabi, Austria; a starch solution that is of low molecular weight and has a low degree of substitution; HES). These plasma expanders were used for a 50% (blood volume) exchange transfusion to simulate preoperative hemodilution. Exchange transfusion was followed by a 60% (blood volume) hemorrhage to reproduce a severe surgical bleed over a 1 hour period. Observation of the animal was continued for another hour during the shock phase. Results The PEG-albumin group exhibited significantly greater survival rate than did the HES group, in which none of the animals survived the hemorrhage phase of the experiment. Among the treatment groups there were no changes in mean arterial pressure and heart rate from baseline after hemodilution. Both groups experienced gradual increases in arterial oxygen tension and disturbance in acid-base balance, but this response was more pronounced in the HES group during the shock period. Mean arterial pressure remained elevated after the initial hemorrhage period in the PEG-albumin group but not in the HES group. Maintenance of a greater mean arterial pressure during the initial stages of hemorrhage is proposed to be in part due to the improved volume expansion with PEG-albumin, as indicated by the significant decrease in systemic hematocrit compared with the HES group. PEG-albumin treatment yielded higher functional capillary density during the initial stages of hemorrhage as compared with HES treatment. Conclusion The ability of PEG-albumin to prolong maintenance of microvascular function better than HES is a finding that would be significant in a clinical setting involving preoperative blood management and extreme blood loss.
Collapse
|
27
|
Ananda K, Nacharaju P, Smith PK, Acharya SA, Manjula BN. Analysis of functionalization of methoxy–PEG as maleimide–PEG. Anal Biochem 2008; 374:231-42. [DOI: 10.1016/j.ab.2007.11.034] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2007] [Revised: 11/22/2007] [Accepted: 11/27/2007] [Indexed: 11/28/2022]
|
28
|
Cabrales P, Intaglietta M. Time-dependant oxygen partial pressure in capillaries and tissue in the hamster window chamber model. Antioxid Redox Signal 2007; 9:845-53. [PMID: 17508910 DOI: 10.1089/ars.2007.1584] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
The possibility of a plasma oxygen diffusion barrier implies a significant resistance to oxygen diffusion and the existence of capillary erythrocyte-associated transients of oxygen. This effect was analyzed by measuring intracapillary blood and tissue pO(2) in the hamster chamber window model using a noninvasive intravital microscopy palladium porphyrin phosphorescence decay technique for two set light excitations (high and low). Using high light excitation, intracapillary blood pO(2) was 13.7 +/- 6.1 mm Hg, and increased to 18.0 +/- 4.5 mm Hg for low light excitation. For high light excitation, intracapillary blood pO(2) peaks were in the range of 25-30 mm Hg, and the lowest values were in the range of 5-10 mm Hg. Reducing the excitation provided a more uniform pO(2) ranging 15-25 mm Hg. With temporal reduction in blood capillary pO(2), levels were correlated to the increase in phosphorescent amplitude that corresponded to plasma gaps. Tissue pO(2) measured at low light excitation in the proximity of capillaries was 23.1 +/- 1.8 mm Hg. In conclusion, low intracapillary blood pO(2) measurements at full hematocrit are an artifact, only observed when oxygen consumption by the measurement technique was excessive and/or absorption of the excitation light was increased by the absence of RBCs. These findings suggest that resistance to oxygen diffusion in plasma is a minor factor in tissue oxygenation by capillaries in the hamster model.
Collapse
|
29
|
Buehler PW, Boykins RA, Norris S, Alayash AI. Chemical Characterization of Diaspirin Cross-Linked Hemoglobin Polymerized with Poly(ethylene glycol). Anal Chem 2006; 78:4634-41. [PMID: 16808476 DOI: 10.1021/ac060188q] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
A lack of specificity associated with chemical modification methods used in the preparation of certain hemoglobin (Hb)-based oxygen carriers (HBOCs) may alter Hb structure and function, as amino acids located in critical regions (e.g., alpha-beta interfaces and the 2,3-DPG binding pocket) may unintentionally be targeted. Hb protein surface modifications with various poly(ethylene glycol) (PEG) derivatives have been used as conjugating and polymerizing agents with the intent of improving reaction site specificity/reproducibility and ultimately reducing the untoward hypertensive response due to nitric oxide scavenging by smaller molecular size tetrameric species (i.e., 64 kDa) in HBOC solutions. Previous experiments performed in our laboratory have evaluated the influence of polymerization of diaspirin alpha-alpha cross-linked Hb (alphaalpha-DBBF-Hb) with a bifunctional modified PEG, bis(maleoylglycylamide) PEG (BMAA-PEG), in terms of oxygen carrying capacity, redox properties, hypertensive response, and renal clearance in rats. The data presented in this paper specifically evaluate the influence of BMAA-PEG on alphaalpha-DBBF-Hb (Poly-alphaalpha-DBBF-Hb) to identify molecular weight distribution, protein conformation, and site-specific modification, as well as to provide insight into the previously determined in vitro and in vivo functional and vasoactive characteristics of this HBOC. Chemical analysis performed herein reveals nonspecific modifications induced by BMAA-PEG that result in the full modification of alphaalpha-DBBF-Hb leaving no tetrameric cross-linked starting material in solution. These data are inconsistent with the continuing assumption that molecular size (i.e., 64 kDa) has a direct influence on HBOC-mediated vasoactivity and that other protective strategies should be considered to control blood pressure imbalances.
Collapse
Affiliation(s)
- Paul W Buehler
- Laboratory of Biochemistry and Vascular Biology, Division of Hematology, Center for Biologics Evaluation and Research (CBER), Food and Drug Administration (FDA), Bethesda, Maryland 20892, USA
| | | | | | | |
Collapse
|