1
|
Constantinides C, Angeli S, Kossivas F, Ktorides P. Underestimation of Murine Cardiac Hemodynamics Using Invasive Catheters: Errors, Limitations, and Remedies. Cardiovasc Eng Technol 2012. [DOI: 10.1007/s13239-012-0084-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
2
|
Constantinides C, Angeli SI, Mean RJ. Murine cardiac catheterizations and hemodynamics: on the issue of parallel conductance. IEEE Trans Biomed Eng 2011; 58:3260-8. [PMID: 21900070 DOI: 10.1109/tbme.2011.2167147] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Catheter-based measurements are extensively used nowadays in animal models to quantify global left ventricular (LV) cardiac function and hemodynamics. Conductance catheter measurements yield estimates of LV volumes. Such estimates, however, are confounded by the catheter's nonhomogeneous emission field and the contribution to the total conductance of surrounding tissue or blood conductance values (other than LV blood), a term often known as parallel conductance. In practice, in most studies, volume estimates are based on the assumptions that the catheter's electric field is homogeneous and that parallel conductance is constant, despite prior results showing that these assumptions are incorrect. This study challenges the assumption for spatial homogeneity of electric field excitation of miniature catheters and investigated the electric field distribution of miniature catheters in the murine heart, based on cardiac model-driven (geometric, lump component) simulations and noninvasive imaging, at both systolic and diastolic cardiac phases. Results confirm the nonuniform catheter emission field, confined spatially within the LV cavity and myocardium, falling to 10% of its peak value at the ring electrode surface, within 1.1-2.0 mm, given a relative tissue permittivity of 33,615. Additionally, <1% of power leaks were observed into surrounding cavities or organs at end-diastole. Temporally varying parallel conductance effects are also confirmed, becoming more prominent at end-systole.
Collapse
|
3
|
Constantinides C, Angeli S, Mean R. Murine cardiac hemodynamics following manganese administration under isoflurane anesthesia. Ann Biomed Eng 2011; 39:2706-20. [PMID: 21818535 DOI: 10.1007/s10439-011-0367-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2011] [Accepted: 07/21/2011] [Indexed: 12/22/2022]
Abstract
This study examines (a) the temporal stability of hemodynamic indices of systolic and diastolic function in C57BL/6 mice under 1.5% isoflurane (ISO) (v/v) anesthesia conditions in 50:50 O(2)/N(2)O (v/v) within 90 min post-induction, and (b) the effects of Mn(2+) on the mouse hemodynamic response in male C57BL/6 mice (n = 16). Left ventricular catheterizations allowed estimation of the hemodynamic indices. Hypertonic saline infusion (10%) allowed absolute volume quantification in conjunction with a separate series of aortic flow experiments (n = 3). In a separate cohort of mice (n = 6), MnCl(2) (190 nmoles/g/bw) was infused via the left jugular for 29-39 min, following 11 min of baseline recording, to assess temporal responses. Stable temporal hemodynamic responses were achieved in control mice under ISO anesthesia. Hemodynamic indices during control, time-matched-control, baseline-Mn, and Mn-infused periods, were within normal expected ranges. No chronotropic changes were observed. Significant differences in systolic and diastolic cardiac indices of function (HR, EF, ESP, dP/dt (max), dP/dt (min), PAMP, τ(glantz), and τ(weiss)) resulted between baseline-Mn and Mn-infused time periods in Mn-treated mice at the 1% significance (p < 0.001). Transient positive, or negative, or positive followed by negative evoked pressure-volume loop shifts were observed (exemplified through changes in the end-systolic pressure-volume relationship and dP/dt (max)) in Mn-infusion studies. It is concluded that Mn(2+) can be used safely for prolonged mouse imaging studies, however, the significant variations elicited in cardiovascular hemodynamics post-manganese infusion, necessitate further investigations for its suitability and appropriateness for quantification of global cardiac function in image-based phenotyping.
Collapse
Affiliation(s)
- C Constantinides
- Laboratory of Physiology and Biomedical Imaging, Department of Mechanical and Manufacturing Engineering, School of Engineering, University of Cyprus, Nicosia, Cyprus.
| | | | | |
Collapse
|
4
|
Chia-Ling Wei, Chung-Dann Kan, Jieh-Neng Wang, Yi-Wen Wang, Chin-Hong Chen, Mei-Ling Tsai. Does Conductance Catheter Measurement System Give Consistent and Reliable Pressure–Volume Relations in Rats? IEEE Trans Biomed Eng 2011; 58:1804-13. [DOI: 10.1109/tbme.2011.2118210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
5
|
Krenz M. Conductance, admittance, and hypertonic saline: should we take ventricular volume measurements with a grain of salt? J Appl Physiol (1985) 2009; 107:1683-4. [DOI: 10.1152/japplphysiol.01089.2009] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Affiliation(s)
- Maike Krenz
- Department of Medical Pharmacology and Physiology, University of Missouri-Columbia, Columbia, Missouri
| |
Collapse
|
6
|
Porterfield JE, Kottam ATG, Raghavan K, Escobedo D, Jenkins JT, Larson ER, Treviño RJ, Valvano JW, Pearce JA, Feldman MD. Dynamic correction for parallel conductance, GP, and gain factor, alpha, in invasive murine left ventricular volume measurements. J Appl Physiol (1985) 2009; 107:1693-703. [PMID: 19696357 DOI: 10.1152/japplphysiol.91322.2008] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
The conductance catheter technique could be improved by determining instantaneous parallel conductance (G(P)), which is known to be time varying, and by including a time-varying calibration factor in Baan's equation [alpha(t)]. We have recently proposed solutions to the problems of both time-varying G(P) and time-varying alpha, which we term "admittance" and "Wei's equation," respectively. We validate both our solutions in mice, compared with the currently accepted methods of hypertonic saline (HS) to determine G(P) and Baan's equation calibrated with both stroke volume (SV) and cuvette. We performed simultaneous echocardiography in closed-chest mice (n = 8) as a reference for left ventricular (LV) volume and demonstrate that an off-center position for the miniaturized pressure-volume (PV) catheter in the LV generates end-systolic and diastolic volumes calculated by admittance with less error (P < 0.03) (-2.49 +/- 15.33 microl error) compared with those same parameters calculated by SV calibrated conductance (35.89 +/- 73.22 microl error) and by cuvette calibrated conductance (-7.53 +/- 16.23 microl ES and -29.10 +/- 31.53 microl ED error). To utilize the admittance approach, myocardial permittivity (epsilon(m)) and conductivity (sigma(m)) were calculated in additional mice (n = 7), and those results are used in this calculation. In aortic banded mice (n = 6), increased myocardial permittivity was measured (11,844 +/- 2,700 control, 21,267 +/- 8,005 banded, P < 0.05), demonstrating that muscle properties vary with disease state. Volume error calculated with respect to echo did not significantly change in aortic banded mice (6.74 +/- 13.06 microl, P = not significant). Increased inotropy in response to intravenous dobutamine was detected with greater sensitivity with the admittance technique compared with traditional conductance [4.9 +/- 1.4 to 12.5 +/- 6.6 mmHg/microl Wei's equation (P < 0.05), 3.3 +/- 1.2 to 8.8 +/- 5.1 mmHg/microl using Baan's equation (P = not significant)]. New theory and method for instantaneous G(P) removal, as well as application of Wei's equation, are presented and validated in vivo in mice. We conclude that, for closed-chest mice, admittance (dynamic G(P)) and Wei's equation (dynamic alpha) provide more accurate volumes than traditional conductance, are more sensitive to inotropic changes, eliminate the need for hypertonic saline, and can be accurately extended to aortic banded mice.
Collapse
Affiliation(s)
- John E Porterfield
- Department of Electrical and Computer Engineering, The University of Texas, Austin, Texas 78229-3900, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Wei CL, Shih MH. Calibration Capacity of the Conductance-to-Volume Conversion Equations for the Mouse Conductance Catheter Measurement System. IEEE Trans Biomed Eng 2009; 56:1627-34. [DOI: 10.1109/tbme.2009.2016215] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
8
|
Chen CE, Wei CL. Bandwidth measurement of the conductance catheter system. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2009; 2008:4859-62. [PMID: 19163805 DOI: 10.1109/iembs.2008.4650302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Conductance catheter system is used to estimate real-time ventricular volume by measuring the time-varying ventricular conductance/admittance. However, the system is generally calibrated only with known resistors, while neither the frequency response nor the bandwidth of the system is calibrated and measured. The main difficulty of measuring its bandwidth is that the sensed signal of the conductance catheter system, which can be viewed as the input of the system, is a modulated signal, rather than a typical sin wave. Therefore, its bandwidth cannot be measured by typical frequency response analyzers, since they are designed for pure sin-wave input. The waveform of the sensed signal is analyzed. Moreover, a waveform simulator designed to mimic the sensed signal is presented. It can be used to measure the bandwidth of conductance catheter system.
Collapse
Affiliation(s)
- Chieh-En Chen
- Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan
| | | |
Collapse
|
9
|
Hassink RJ, Nakajima H, Nakajima HO, Doevendans PA, Field LJ. Expression of a transgene encoding mutant p193/CUL7 preserves cardiac function and limits infarct expansion after myocardial infarction. Heart 2009; 95:1159-64. [PMID: 19435717 DOI: 10.1136/hrt.2008.150128] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Transgenic mice expressing the dominant interfering p193 protein in cardiomyocytes (MHC-1152stop mice) exhibit an induction of cell cycle activity and altered remodelling after experimental myocardial infarction (MI). OBJECTIVE To determine whether the altered remodelling results in improved cardiac function in the MHC-1152stop mice after MI, as compared with non-transgenic mice. METHODS MHC-1152stop mice and non-transgenic littermates were subjected to experimental MI via permanent occlusion of the coronary artery. Infarct size was determined at 24 h and at 4 weeks after MI, and left ventricular pressure-volume measurements were performed at 4 weeks after MI in infarcted and sham-operated animals. RESULTS Infarct size in MHC-1152stop mice and non-transgenic littermates was not statistically different at 24 h after MI, as measured by tetrazolium staining. Morphometric analysis showed that infarct scar expansion at 4 weeks after MI was reduced by 10% in the MHC-1152stop mice (p<0.05). No differences in cardiac function were detected between sham-operated MHC-1152stop mice and their non-transgenic littermates. However, at 4 weeks after MI, the ventricular isovolumic relaxation time constant (tau) was decreased by 19% (p<0.05), and the slope of the dP/dt(max)-EDV relationship was increased 99% (p<0.05), in infarcted MHC-1152stop mice as compared with infarcted non-transgenic littermates. CONCLUSION Expression of the dominant interfering p193 transgene results in a decrease in infarct scar expansion and preservation of myocardial function at 4 weeks after MI. Antagonism of p193 activity may represent an important strategy for the treatment of MI.
Collapse
Affiliation(s)
- R J Hassink
- Department of Cardiology, University Medical Centre, Utrecht, The Netherlands.
| | | | | | | | | |
Collapse
|
10
|
Wei CL, Wu PY. Investigation of mouse conductance catheter position deviation effects on volume measurements by finite element models. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2008; 2008:1399-1402. [PMID: 19162930 DOI: 10.1109/iembs.2008.4649427] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
The conductance catheter system is used to measure the instantaneous ventricular conductance, and real-time ventricular volumes is then determined by converting the measured conductance to volume. In fact, two different conductance-to-volume conversion equations for conductance catheters have been proposed, the Baan's classic equation and Wei's nonlinear equation. The accuracy of this volume estimation method is limited by several factors, such as the deviation of the catheter position inside the ventricle. The effects of the mouse catheter radial and longitudinal position deviations on the measured conductance are investigated with finite element models. Moreover, the capacities of the two conversion equations to calibrate the error induced by the catheter position variation are evaluated and compared. According to the simulation results, the error-calibrated capacity of the nonlinear conversion equation is better.
Collapse
Affiliation(s)
- Chia-Ling Wei
- Department of Electrical Engineering, National Cheng Kung University, Tainan, Taiwan.
| | | |
Collapse
|
11
|
Hassink RJ, Pasumarthi KB, Nakajima H, Rubart M, Soonpaa MH, de la Rivière AB, Doevendans PA, Field LJ. Cardiomyocyte cell cycle activation improves cardiac function after myocardial infarction. Cardiovasc Res 2007; 78:18-25. [PMID: 18079102 DOI: 10.1093/cvr/cvm101] [Citation(s) in RCA: 100] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
AIMS Cardiomyocyte loss is a major contributor to the decreased cardiac function observed in diseased hearts. Previous studies have shown that cardiomyocyte-restricted cyclin D2 expression resulted in sustained cell cycle activity following myocardial injury in transgenic (MHC-cycD2) mice. Here, we investigated the effects of this cell cycle activation on cardiac function following myocardial infarction (MI). METHODS AND RESULTS MI was induced in transgenic and non-transgenic mice by left coronary artery occlusion. At 7, 60, and 180 days after MI, left ventricular pressure-volume measurements were recorded and histological analysis was performed. MI had a similar adverse effect on cardiac function in transgenic and non-transgenic mice at 7 days post-injury. No improvement in cardiac function was observed in non-transgenic mice at 60 and 180 days post-MI. In contrast, the transgenic animals exhibited a progressive and marked increase in cardiac function at subsequent time points. Improved cardiac function in the transgenic mice at 60 and 180 days post-MI correlated positively with the presence of newly formed myocardial tissue which was not apparent at 7 days post-MI. Intracellular calcium transient imaging indicated that cardiomyocytes present in the newly formed myocardium participated in a functional syncytium with the remote myocardium. CONCLUSION These findings indicate that cardiomyocyte cell cycle activation leads to improvement of cardiac function and morphology following MI and may represent an important clinical strategy to promote myocardial regeneration.
Collapse
Affiliation(s)
- Rutger J Hassink
- Department of Cardiology, University Medical Center, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Wei CL, Valvano JW, Feldman MD, Nahrendorf M, Peshock R, Pearce JA. Volume catheter parallel conductance varies between end-systole and end-diastole. IEEE Trans Biomed Eng 2007; 54:1480-9. [PMID: 17694869 DOI: 10.1109/tbme.2007.890732] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In order for the conductance catheter system to accurately measure instantaneous cardiac blood volume, it is necessary to determine and remove the contribution from parallel myocardial tissue. In previous studies, the myocardium has been treated as either purely resistive or purely capacitive when developing methods to estimate the myocardial contribution. We propose that both the capacitive and the resistive properties of the myocardium are substantial, and neither should be ignored. Hence, the measured result should be labeled admittance rather than conductance. We have measured the admittance (magnitude and phase angle) of the left ventricle in the mouse, and have shown that it is measurable and increases with frequency. Further, this more accurate technique suggests that the myocardial contribution to measured admittance varies between end-systole and end-diastole, contrary to previous literature. We have tested these hypotheses both with numerical finite-element models for a mouse left ventricle constructed from magnetic resonance imaging images, and with in vivo admittance measurements in the murine left ventricle. Finally, we propose a new method to determine the instantaneous myocardial contribution to the measured left ventricular admittance that does not require saline injection or other intervention to calibrate.
Collapse
Affiliation(s)
- Chia-Ling Wei
- Department of Electrical Engineering, National Cheng Kung University, No. 1 University Road, Tainan 70101, Taiwan.
| | | | | | | | | | | |
Collapse
|
13
|
Nielsen JM, Kristiansen SB, Ringgaard S, Nielsen TT, Flyvbjerg A, Redington AN, Bøtker HE. Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration. Am J Physiol Heart Circ Physiol 2007; 293:H534-40. [PMID: 17384122 DOI: 10.1152/ajpheart.01268.2006] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The conductance catheter (CC) allows thorough evaluation of cardiac function because it simultaneously provides measurements of pressure and volume. Calibration of the volume signal remains challenging. With different calibration techniques, in vivo left ventricular volumes (VCC) were measured in mice ( n = 52) with a Millar CC (SPR-839) and compared with MRI-derived volumes (VMRI). Significant correlations between VCC and VMRI [end-diastolic volume (EDV): R2 = 0.85, P < 0.01; end-systolic volume (ESV): R2 = 0.88, P < 0.01] were found when injection of hypertonic saline in the pulmonary artery was used to calibrate for parallel conductance and volume conversion was done by individual cylinder calibration. However, a significant underestimation was observed [EDV = −17.3 μl (−22.7 to −11.9 μl); ESV = −8.8 μl (−12.5 to −5.1 μl)]. Intravenous injection of the hypertonic saline bolus was inferior to injection into the pulmonary artery as a calibration method. Calibration with an independent measurement of stroke volume decreased the agreement with VMRI. Correction for an increase in blood conductivity during the in vivo experiments improved estimation of EDV. The dual-frequency method for estimation of parallel conductance failed to produce VCC that correlated with VMRI. We conclude that selection of the calibration procedure for the CC has significant implications for the accuracy and precision of volume estimation and pressure-volume loop-derived variables like myocardial contractility. Although VCC may be underestimated compared with MRI, optimized calibration techniques enable reliable volume estimation with the CC in mice.
Collapse
Affiliation(s)
- Jan Møller Nielsen
- Department of Cardiology B, Aarhus University Hospital, Skejby, 8200 Aarhus N, Denmark.
| | | | | | | | | | | | | |
Collapse
|
14
|
Wei CL, Valvano JW, Feldman MD, Altman D, Kottam A, Raghavan K, Fernandez DJ, Reyes M, Escobedo D, Pearce JA. Evidence of time-varying myocardial contribution by in vivo magnitude and phase measurement in mice. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2007; 2004:3674-7. [PMID: 17271090 DOI: 10.1109/iembs.2004.1404032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Cardiac volume can be estimated by a conductance catheter system. Both blood and myocardium are conductive, but only the blood conductance is desired. Therefore, the parallel myocardium contribution should be removed from the total measured conductance. Several methods have been developed to estimate the contribution from myocardium, and they only determine a single steady state value for the parallel contribution. Besides, myocardium was treated as purely resistive or mainly capacitive when estimating the myocardial contribution. We question these assumptions and propose that the myocardium is both resistive and capacitive, and its contribution changes during a single cardiac cycle. In vivo magnitude and phase experiments were performed in mice to confirm this hypothesis.
Collapse
Affiliation(s)
- Chia-Ling Wei
- Department of Electrical and Computer Engineering, The University of Texas at Austin, TX, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Colston JT, Boylston WH, Feldman MD, Jenkinson CP, de la Rosa SD, Barton A, Trevino RJ, Freeman GL, Chandrasekar B. Interleukin-18 knockout mice display maladaptive cardiac hypertrophy in response to pressure overload. Biochem Biophys Res Commun 2007; 354:552-8. [PMID: 17250807 PMCID: PMC1847636 DOI: 10.1016/j.bbrc.2007.01.030] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2006] [Accepted: 01/04/2007] [Indexed: 10/23/2022]
Abstract
Interleukin (IL)-18 is a cardiotropic proinflammatory cytokine chronically elevated in the serum of patients with cardiac hypertrophy (LVH). The purpose of this study was to examine the role of IL-18 in pressure-overload hypertrophy using wild type (WT) and IL-18 -/- (null) mice. Adult male C57Bl/6 mice underwent transaortic constriction (TAC) for 7days or sham surgery. Heart weight/body weight ratios showed blunted hypertrophy in IL-18 null TAC mice compared to WT TAC animals. Microarray analyses indicated differential expression of hypertrophy-related genes in WT versus IL-18 nulls. Northern, Western, and EMSA analyses showed Akt and GATA4 were increased in WT but unchanged in IL-18 null mice. Our results demonstrate blunted hypertrophy with reduced expression of contractile-, hypertrophy-, and remodeling-associated genes following pressure overload in IL-18 null mice, and suggest that IL-18 plays a critical role in the hypertrophic response.
Collapse
Affiliation(s)
- James T. Colston
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| | - William H. Boylston
- Biochemistry, University of Texas Health Science Center, San Antonio, TX 78229
| | - Marc D. Feldman
- South Texas Veterans Health Care System, San Antonio, TX, USA
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| | - Chris P. Jenkinson
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| | - Sam D. de la Rosa
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| | - Amanda Barton
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| | - Rodolfo J. Trevino
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| | - Gregory L. Freeman
- South Texas Veterans Health Care System, San Antonio, TX, USA
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| | - Bysani Chandrasekar
- South Texas Veterans Health Care System, San Antonio, TX, USA
- Medicine, University of Texas Health Science Center, San Antonio, TX 78229
| |
Collapse
|
16
|
Jegger D, Mallik AS, Nasratullah M, Jeanrenaud X, da Silva R, Tevaearai H, von Segesser LK, Stergiopulos N. The effect of a myocardial infarction on the normalized time-varying elastance curve. J Appl Physiol (1985) 2006; 102:1123-9. [PMID: 17158245 DOI: 10.1152/japplphysiol.00976.2006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
It has been suggested that the shape of the normalized time-varying elastance curve [E(n)(t(n))] is conserved in different cardiac pathologies. We hypothesize, however, that the E(n)(t(n)) differs quantitatively after myocardial infarction (MI). Sprague-Dawley rats (n = 9) were anesthetized, and the left anterior descending coronary artery was ligated to provoke the MI. A sham-operated control group (CTRL) (n = 10) was treated without the MI. Two months later, a conductance catheter was inserted into the left ventricle (LV). The LV pressure and volume were measured and the E(n)(t(n)) derived. Slopes of E(n)(t(n)) during the preejection period (alpha(PEP)), ejection period (alpha(EP)), and their ratio (beta = alpha(EP)/alpha(PEP)) were calculated, together with the characteristic decay time during isovolumic relaxation (tau) and the normalized elastance at end diastole (E(min)(n)). MI provoked significant LV chamber dilatation, thus a loss in cardiac output (-33%), ejection fraction (-40%), and stroke volume (-30%) (P < 0.05). Also, it caused significant calcium increase (17-fold), fibrosis (2-fold), and LV hypertrophy. End-systolic elastance dropped from 0.66 +/- 0.31 mmHg/microl (CTRL) to 0.34 +/- 0.11 mmHg/microl (MI) (P < 0.05). Normalized elastance was significantly reduced in the MI group during the preejection, ejection, and diastolic periods (P < 0.05). The slope of E(n)(t(n)) during the alpha(PEP) and beta were significantly altered after MI (P < 0.05). Furthermore, tau and end-diastolic E(min)(n) were both significantly augmented in the MI group. We conclude that the E(n)(t(n)) differs quantitatively in all phases of the heart cycle, between normal and hearts post-MI. This should be considered when utilizing the single-beat concept.
Collapse
Affiliation(s)
- David Jegger
- Laboratory of Haemodynamics and Cardiovascular Technology, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Reyes M, Steinhelper ME, Alvarez JA, Escobedo D, Pearce J, Valvano JW, Pollock BH, Wei CL, Kottam A, Altman D, Bailey S, Thomsen S, Lee S, Colston JT, Oh JH, Freeman GL, Feldman MD. Impact of physiological variables and genetic background on myocardial frequency-resistivity relations in the intact beating murine heart. Am J Physiol Heart Circ Physiol 2006; 291:H1659-69. [PMID: 16699072 DOI: 10.1152/ajpheart.00609.2005] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Conductance measurements for generation of an instantaneous left ventricular (LV) volume signal in the mouse are limited, because the volume signal is a combination of blood and LV muscle, and only the blood signal is desired. We have developed a conductance system that operates at two simultaneous frequencies to identify and remove the myocardial contribution to the instantaneous volume signal. This system is based on the observation that myocardial resistivity varies with frequency, whereas blood resistivity does not. For calculation of LV blood volume with the dual-frequency conductance system in mice, in vivo murine myocardial resistivity was measured and combined with an analytic approach. The goals of the present study were to identify and minimize the sources of error in the measurement of myocardial resistivity to enhance the accuracy of the dual-frequency conductance system. We extended these findings to a gene-altered mouse model to determine the impact of measured myocardial resistivity on the calculation of LV pressure-volume relations. We examined the impact of temperature, timing of the measurement during the cardiac cycle, breeding strain, anisotropy, and intrameasurement and interanimal variability on the measurement of intact murine myocardial resistivity. Applying this knowledge to diabetic and nondiabetic 11- and 20- to 24-wk-old mice, we demonstrated differences in myocardial resistivity at low frequencies, enhancement of LV systolic function at 11 wk and LV dilation at 20–24 wk, and histological and electron-microscopic studies demonstrating greater glycogen deposition in the diabetic mice. This study demonstrated the accurate technique of measuring myocardial resistivity and its impact on the determination of LV pressure-volume relations in gene-altered mice.
Collapse
Affiliation(s)
- Maricela Reyes
- Univ. of Texas Health Science Center, 7703 Floyd Curl Dr., San Antonio, TX 78229-3900, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Abstract
Many forms of pediatric and adult heart disease result from a deficiency in cardiomyocyte number. Through repopulation of the heart with new cardiomyocytes (that is, induction of regenerative cardiac growth), cardiac disease potentially can be reversed, provided that the newly formed myocytes structurally and functionally integrate in the preexisting myocardium. A number of approaches have been utilized to effect regenerative growth of the myocardium in experimental animals. These include interventions aimed at enhancing the ability of cardiomyocytes to proliferate in response to cardiac injury, as well as transplantation of cardiomyocytes or myogenic stem cells into diseased hearts. Here we review efforts to induce myocardial regeneration. We also provide a critical review of techniques currently used to assess cardiac regeneration and functional integration of de novo cardiomyocytes.
Collapse
Affiliation(s)
- Michael Rubart
- Herman B Wells Center for Pediatric Research and Krannert Institute of Cardiology, Indiana University School of Medicine, Indianapolis, Indiana 46202-5225, USA.
| | | |
Collapse
|
19
|
Lindsey ML, Goshorn DK, Comte-Walters S, Hendrick JW, Hapke E, Zile MR, Schey K. A multidimensional proteomic approach to identify hypertrophy-associated proteins. Proteomics 2006; 6:2225-35. [PMID: 16493702 DOI: 10.1002/pmic.200500013] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Left ventricular hypertrophy (LVH) is a leading cause of congestive heart failure. The exact mechanisms that control cardiac growth and regulate the transition to failure are not fully understood, in part due to the lack of a complete inventory of proteins associated with LVH. We investigated the proteomic basis of LVH using the transverse aortic constriction model of pressure overload in mice coupled with a multidimensional approach to identify known and novel proteins that may be relevant to the development and maintenance of LVH. We identified 123 proteins that were differentially expressed during LVH, including LIM proteins, thioredoxin, myoglobin, fatty acid binding protein 3, the abnormal spindle-like microcephaly protein (ASPM), and cytoskeletal proteins such as actin and myosin. In addition, proteins with unknown functions were identified, providing new directions for future research in this area. We also discuss common pitfalls and strategies to overcome the limitations of current proteomic technologies. Together, the multidimensional approach provides insight into the proteomic changes that occur in the LV during hypertrophy.
Collapse
Affiliation(s)
- Merry L Lindsey
- Division of Cardiothoracic Surgery Research, Department of Surgery, Medical University of South Carolina, Charleston, SC, USA.
| | | | | | | | | | | | | |
Collapse
|
20
|
Kottam ATG, Porterfield J, Raghavan K, Fernandez D, Feldman MD, Valvano JW, Pearce JA. Real time pressure-volume loops in mice using complex admittance: measurement and implications. CONFERENCE PROCEEDINGS : ... ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL CONFERENCE 2006; 2006:4336-4339. [PMID: 17946238 DOI: 10.1109/iembs.2006.259407] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Real time left ventricular (LV) pressure-volume (P-V) loops have provided a framework for understanding cardiac mechanics in experimental animals and humans. Conductance measurements have been used for the past 25 years to generate an instantaneous left ventricular (LV) volume signal. The standard conductance method yields a combination of blood and ventricular muscle conductance; however, only the blood signal is used to estimate LV volume. The state of the art techniques like hypertonic saline injection and IVC occlusion, determine only a single steady-state value of the parallel conductance of the cardiac muscle. This is inaccurate, since the cardiac muscle component should vary instantaneously throughout the cardiac cycle as the LV contracts and fills, because the distance from the catheter to the muscle changes. The capacitive nature of cardiac muscle can be used to identify its contribution to the combined conductance signal. This method, in contrast to existing techniques, yields an instantaneous estimate of the parallel admittance of cardiac muscle that can be used to correct the measurement in real time. The corrected signal consists of blood conductance alone. We present the results of real time in vivo measurements of pressure-admittance and pressure-phase loops inside the murine left ventricle. We then use the magnitude and phase angle of the measured admittance to determine pressure volume loops inside the LV on a beat by beat basis. These results may be used to achieve a substantial improvement in the state of the art in this measurement method by eliminating the need for hypertonic saline injection.
Collapse
|
21
|
Wei CL, Valvano JW, Feldman MD, Pearce JA. Nonlinear conductance-volume relationship for murine conductance catheter measurement system. IEEE Trans Biomed Eng 2005; 52:1654-61. [PMID: 16235651 DOI: 10.1109/tbme.2005.856029] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The conductance catheter system is a tool to determine instantaneous left ventricular volume in vivo by converting measured conductance to volume. The currently adopted conductance-to-volume conversion equation was proposed by Baan, and the accuracy of this equation is limited by the assumption of a linear conductance-volume relationship. The electric field generated by a conductance catheter is nonuniform, which results in a nonlinear relationship between conductance and volume. This paper investigates this nonlinear relationship and proposes a new nonlinear conductance-to-volume conversion equation. The proposed nonlinear equation uses a single empirically determined calibration coefficient, derived from independently measured stroke volume. In vitro experiments and numerical model simulations were performed to verify and validate the proposed equation.
Collapse
Affiliation(s)
- Chia-Ling Wei
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX 78712, USA.
| | | | | | | |
Collapse
|
22
|
Lindsey ML, Escobar GP, Dobrucki LW, Goshorn DK, Bouges S, Mingoia JT, McClister DM, Su H, Gannon J, MacGillivray C, Lee RT, Sinusas AJ, Spinale FG. Matrix metalloproteinase-9 gene deletion facilitates angiogenesis after myocardial infarction. Am J Physiol Heart Circ Physiol 2005; 290:H232-9. [PMID: 16126817 DOI: 10.1152/ajpheart.00457.2005] [Citation(s) in RCA: 140] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Matrix metalloproteinases (MMPs) are postulated to be necessary for neovascularization during wound healing. MMP-9 deletion alters remodeling postmyocardial infarction (post-MI), but whether and to what degree MMP-9 affects neovascularization post-MI is unknown. Neovascularization was evaluated in wild-type (WT; n = 63) and MMP-9 null (n = 55) mice at 7-days post-MI. Despite similar infarct sizes, MMP-9 deletion improved left ventricular function as evaluated by hemodynamic analysis. Blood vessel quantity and quality were evaluated by three independent studies. First, vessel density was increased in the infarct of MMP-9 null mice compared with WT, as quantified by Griffonia (Bandeiraea) simplicifolia lectin I (GSL-I) immunohistochemistry. Second, preexisting vessels, stained in vivo with FITC-labeled GSL-I pre-MI, were present in the viable but not MI region. Third, a technetium-99m-labeled peptide (NC100692), which selectively binds to activated alpha(v)beta3-integrin in angiogenic vessels, was injected into post-MI mice. Relative NC100692 activity in myocardial segments with diminished perfusion (0-40% nonischemic) was higher in MMP-9 null than in WT mice (383 +/- 162% vs. 250 +/- 118%, respectively; P = 0.002). The unique finding of this study was that MMP-9 deletion stimulated, rather than impaired, neovascularization in remodeling myocardium. Thus targeted strategies to inhibit MMP-9 early post-MI will likely not impair the angiogenic response.
Collapse
Affiliation(s)
- Merry L Lindsey
- Division of Cardiothoracic Surgery Research, Rm. 629, Strom Thurmond Research Bldg., 770 MUSC Complex, Medical Univ. of South Carolina, 114 Doughty St., PO Box 250778, Charleston, SC 29425, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
How OJ, Aasum E, Kunnathu S, Severson DL, Myhre ESP, Larsen TS. Influence of substrate supply on cardiac efficiency, as measured by pressure-volume analysis in ex vivo mouse hearts. Am J Physiol Heart Circ Physiol 2005; 288:H2979-85. [PMID: 15764683 DOI: 10.1152/ajpheart.00084.2005] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
In the present study, we tested the reliability of measurements of pressure-volume area (PVA) and oxygen consumption (MV̇o2) in ex vivo mouse hearts, combining the use of a miniaturized conductance catheter and a fiber-optic oxygen sensor. Second, we tested whether we could reproduce the influence of increased myocardial fatty acid (FA) metabolism on cardiac efficiency in the isolated working mouse heart model, which has already been documented in large animal models. The hearts were perfused with crystalloid buffer containing 11 mM glucose and two different concentrations of FA bound to 3% BSA. The initial concentration was 0.3 ± 0.1 mM, which was subsequently raised to 0.9 ± 0.1 mM. End-systolic and end-diastolic pressure-volume relationships were assessed by temporarily occluding the preload line. Different steady-state PVA-MV̇o2relationships were obtained by changing the loading conditions (pre- and afterload) of the heart. There were no apparent changes in baseline cardiac performance or contractile efficiency (slope of the PVA-MV̇o2regression line) in response to the elevation of the perfusate FA concentration. However, all hearts ( n = 8) showed an increase in the y-intercept of the PVA-MV̇o2regression line after elevation of the palmitate concentration, indicating an FA-induced increase in the unloaded MV̇o2. Therefore, in the present model, unloaded MV̇o2is not independent of metabolic substrate. This is, to our knowledge, the first report of a PVA-MV̇o2relationship in ex vivo perfused murine hearts, using a pressure-volume catheter. The methodology can be an important tool for phenotypic assessment of the relationship among metabolism, contractile performance, and cardiac efficiency in various mouse models.
Collapse
Affiliation(s)
- Ole-Jakob How
- Dept. of Medical Physiology, Institute of Medical Biology, Faculty of Medicine, Univ. of Tromsø, Tromsø N-9037 Norway.
| | | | | | | | | | | |
Collapse
|
24
|
Shimizu M, Konstantinov IE, Suess AM, Cheung M, McCrindle BW, Vogel M, Redington AN. Noninvasive Analysis of Myocardial Function Using High-Resolution Doppler Tissue Echocardiography in Rats. J Am Soc Echocardiogr 2005; 18:461-7. [PMID: 15891756 DOI: 10.1016/j.echo.2005.01.035] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Mikiko Shimizu
- Division of Cardiology, Hospital for Sick Children, Toronto, Ontario, Canada.
| | | | | | | | | | | | | |
Collapse
|
25
|
Ikonomidis JS, Hendrick JW, Parkhurst AM, Herron AR, Escobar PG, Dowdy KB, Stroud RE, Hapke E, Zile MR, Spinale FG. Accelerated LV remodeling after myocardial infarction in TIMP-1-deficient mice: effects of exogenous MMP inhibition. Am J Physiol Heart Circ Physiol 2005; 288:H149-58. [PMID: 15598866 DOI: 10.1152/ajpheart.00370.2004] [Citation(s) in RCA: 106] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Alterations in matrix metalloproteinases (MMPs) and tissue inhibitors of MMPs (TIMPs) have been implicated in adverse left ventricular (LV) remodeling after myocardial infarction (MI). However, the direct mechanistic role of TIMPs in the post-MI remodeling process has not been completely established. The goal of this project was to define the effects of altering endogenous MMP inhibitory control through combined genetic and pharmacological approaches on post-MI remodeling in mice. This study examined the effects of MMP inhibition (MMPi) with PD-166793 (30 mg.kg(-1).day(-1)) on LV geometry and function (conductance volumetry) after MI in wild-type (WT) mice and mice deficient in the TIMP-1 gene [TIMP-1 knockout (TIMP1-KO)]. At 3 days after MI (coronary ligation), mice were randomized into four groups: WT-MI/MMPi (n = 10), TIMP1-KO-MI/MMPi (n = 10), WT-MI (n = 22), and TIMP1-KO-MI (n = 23). LV end-diastolic volume (EDV) and ejection fraction were determined 14 days after MI. Age-matched WT (n = 20) and TIMP1-KO (n = 28) mice served as reference controls. LVEDV was similar under control conditions in WT and TIMP1-KO mice (36 +/- 2 and 40 +/- 2 microl, respectively) but was greater in TIMP1-KO-MI than in WT-MI mice (48 +/- 2 vs. 61 +/- 5 microl, P < 0.05). LVEDV was reduced from MI-only values in WT-MI/MMPi and TIMP1-KO-MI/MMPi mice (42 +/- 2 and 36 +/- 2 microl, respectively, P < 0.05) but was reduced to the greatest degree in TIMP1-KO mice (P < 0.05). LV ejection fraction was reduced in both groups after MI and increased in TIMP1-KO-MI/MMPi, but not in WT-MI/MMPi, mice. These unique results demonstrated that myocardial TIMP-1 plays a regulatory role in post-MI remodeling and that the accelerated myocardial remodeling induced by TIMP-1 gene deletion can be pharmacologically "rescued" by MMP inhibition. These results define the importance of local endogenous control of MMP activity with respect to regulating LV structure and function after MI.
Collapse
Affiliation(s)
- John S Ikonomidis
- Division of Cardiothoracic Surgery, Medical University of South Carolina, 114 Doughty St., Charleston, SC 29425, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Uemura K, Kawada T, Sugimachi M, Zheng C, Kashihara K, Sato T, Sunagawa K. A self-calibrating telemetry system for measurement of ventricular pressure-volume relations in conscious, freely moving rats. Am J Physiol Heart Circ Physiol 2005; 287:H2906-13. [PMID: 15548729 DOI: 10.1152/ajpheart.00035.2004] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Using Bluetooth wireless technology, we developed an implantable telemetry system for measurement of the left ventricular pressure-volume relation in conscious, freely moving rats. The telemetry system consisted of a pressure-conductance catheter (1.8-Fr) connected to a small (14-g) fully implantable signal transmitter. To make the system fully telemetric, calibrations such as blood resistivity and parallel conductance were also conducted telemetrically. To estimate blood resistivity, we used four electrodes arranged 0.2 mm apart on the pressure-conductance catheter. To estimate parallel conductance, we used a dual-frequency method. We examined the accuracy of calibrations, stroke volume (SV) measurements, and the reproducibility of the telemetry. The blood resistivity estimated telemetrically agreed with that measured using an ex vivo cuvette method (y=1.09x - 11.9, r2= 0.88, n=10). Parallel conductance estimated by the dual-frequency (2 and 20 kHz) method correlated well with that measured by a conventional saline injection method (y=1.59x - 1.77, r2= 0.87, n=13). The telemetric SV closely correlated with the flowmetric SV during inferior vena cava occlusions (y=0.96x + 7.5, r2=0.96, n=4). In six conscious rats, differences between the repeated telemetries on different days (3 days apart on average) were reasonably small: 13% for end-diastolic volume, 20% for end-systolic volume, 28% for end-diastolic pressure, and 6% for end-systolic pressure. We conclude that the developed telemetry system enables us to estimate the pressure-volume relation with reasonable accuracy and reproducibility in conscious, untethered rats.
Collapse
Affiliation(s)
- Kazunori Uemura
- Dept. of Cardiovascular Dynamics, National Cardiovascular Center Research Institute, 5-7-1, Fujishirodai, Suita 565-8565, Japan.
| | | | | | | | | | | | | |
Collapse
|
27
|
Alvarez JA, Reyes M, Escobedo D, Freeman GL, Steinhelper ME, Feldman MD. Enhanced left ventricular systolic function early in type 2 diabetic mice: clinical implications. Diab Vasc Dis Res 2004; 1:89-94. [PMID: 16302647 DOI: 10.3132/dvdr.2004.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
It is unclear whether the increase in availability of substrates for energy production in diabetes can lead to enhanced systolic function early in the disease, before the onset of structural changes to the myocardium. To examine this issue, BKS.Cg-m +/+ Lepr db (db/db) mice with type 2 diabetes and wild type controls had left ventricular pressure-volume relationships determined in situ. We demonstrated that the db/db mice, when compared to their wild type controls, generated greater left ventricular pressure and an enhancement of left ventricular systolic function based on enhanced power/EDV, positive dP/dt, preload recruitable stroke work, dP/dt--EDV relationship, and curvilinear end-systolic elastance. This enhancement in systolic function occurred despite the db/db mice having greater body weight, but similar preload (end-diastolic volume) and afterload (effective arterial elastance). We postulate that the previously described enhancement in renal glomerular filtration rate seen early in type 2 diabetes may be in part due to enhanced left ventricular systolic function early in this disease.
Collapse
Affiliation(s)
- Jorge A Alvarez
- Department of Medicine, University of Texas Health Science Center in San Antonio, San Antonio, Texas, 78229-3900, USA
| | | | | | | | | | | |
Collapse
|
28
|
Hartley CJ, Reddy AK, Madala S, Entman ML, Michael LH, Taffet GE. Noninvasive ultrasonic measurement of arterial wall motion in mice. Am J Physiol Heart Circ Physiol 2004; 287:H1426-32. [PMID: 15317682 DOI: 10.1152/ajpheart.01185.2003] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Despite the extensive use of genetically altered mice to study cardiovascular physiology and pathology, it remains difficult to quantify arterial function noninvasively in vivo. We have developed a noninvasive Doppler method for quantifying vessel wall motion in anesthetized mice. A 20-MHz probe was held by an alligator clip and positioned over the carotid arteries of 16 mice, including six 3- to 5-mo-old wild-type (WT), four 30-mo-old senescent (old), two apolipoprotein E null (ApoE), and four α-smooth muscle actin null (α-SMA) mice. Doppler signals were obtained simultaneously from both vessel walls and from blood flow. The calculated displacement signals from the near and far walls were subtracted to generate a diameter signal from which the excursion and an augmentation index were calculated. The excursion ranged between 13 μm (in ApoE) and 95 μm (in α-SMA). The augmentation index was lowest in the WT mice (0.06) and highest in the old mice (0.29). We conclude that Doppler signal processing may be used to measure vessel wall motion in mice with high spatial and temporal resolution and that diameter signals can replace pressure signals for calculating the augmentation index. This noninvasive method is able to identify and confirm characteristic changes in arterial properties previously associated with age, atherosclerosis, and the absence of vascular tone.
Collapse
Affiliation(s)
- Craig J Hartley
- Department of Medicine, The Methodist DeBakey Heart Center, Baylor College of Medicine, Houston, Texas 77030, USA.
| | | | | | | | | | | |
Collapse
|
29
|
Hartley CJ, Taffet GE, Reddy AK, Entman ML, Michael LH. Noninvasive cardiovascular phenotyping in mice. ILAR J 2003; 43:147-58. [PMID: 12105382 DOI: 10.1093/ilar.43.3.147] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
With the growth of genetic engineering, mice have become common as models of human diseases, which in turn has stimulated the development of techniques to monitor and image the murine cardiovascular system. Invasive methods are often more quantitative, but noninvasive methods are preferred when measurements must be repeated serially on living animals during development or in response to pharmacological or surgical interventions. Because of the small size and high heart rates in mice, high spatial and temporal resolutions are required to preserve signal fidelity. Monitoring of body temperature and the electrocardiogram is essential when animals must be anesthetized for a measurement or other procedure. Several other groups have developed cardiovascular imaging modalities suitable for murine applications, and ultrasound is the most widely used. Our group has developed and applied high-resolution Doppler probes and signal processing for measuring blood velocity in the heart and peripheral vessels of anesthetized mice noninvasively. We can measure cardiac filling and ejection velocities as indices of systolic and diastolic ventricular function and for timing of cardiac events; velocity pulse arrival times for determining pulse-wave velocity and arterial stiffness; peripheral velocity waveforms as indices of arterial resistance, compliance, and wave reflections; stenotic velocities for estimation of pressure drop and detection of vorticity; and tail artery velocity for determining systolic and diastolic blood pressure using a pressure cuff. These noninvasive methods are convenient and easy to apply and have been used to detect and evaluate numerous cardiovascular phenotypes in mutant mice.
Collapse
Affiliation(s)
- Craig J Hartley
- Section of Cardiovascular Sciences, Department of Medicine, DeBakey Heart Center, Baylor College of Medicine, Houston, TX, USA
| | | | | | | | | |
Collapse
|
30
|
Creemers EEJM, Davis JN, Parkhurst AM, Leenders P, Dowdy KB, Hapke E, Hauet AM, Escobar PG, Cleutjens JPM, Smits JFM, Daemen MJAP, Zile MR, Spinale FG. Deficiency of TIMP-1 exacerbates LV remodeling after myocardial infarction in mice. Am J Physiol Heart Circ Physiol 2003; 284:H364-71. [PMID: 12388239 DOI: 10.1152/ajpheart.00511.2002] [Citation(s) in RCA: 141] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Recent studies have been directed at modulating the heart failure process through inhibition of activated matrix metalloproteinases (MMPs). We hypothesized that a loss of MMP inhibitory control by tissue inhibitor of MMP (TIMP)-1 deficiency alters the course of postinfarction chamber remodeling and induced chronic myocardial infarction (MI) in wild-type (WT) and TIMP-1(-/-) mice. Left ventricular (LV) pressure-volume loops obtained from WT and TIMP-1(-/-) mice demonstrated that LV end-diastolic volume [52 +/- 4 (WT) vs. 71 +/- 6 (TIMP-1(-/-)) microl] and LV end-diastolic pressure [9.0 +/- 1.2 (WT) vs. 12.7 +/- 1.4 (TIMP-1(-/-)) mmHg] were significantly increased in the TIMP-1(-/-) mice 2 wk after MI. LV contractility was reduced to a similar degree in the WT and TIMP-1(-/-) groups after MI, as indicated by a significant fall in the LV end-systolic pressure-volume relationship. Ventricular weight and cross-sectional areas of LV myocytes were significantly increased in TIMP-1(-/-) mice, indicating that the hypertrophic response was more pronounced. The observed significant loss of fibrillar collagen in the TIMP-1(-/-) controls may have been an important contributory factor for the observed LV alterations in the TIMP-1(-/-) mice after MI. These findings demonstrate that TIMP-1 deficiency amplifies adverse LV remodeling after MI in mice and emphasizes the importance of local endogenous control of cardiac MMP activity by TIMP-1.
Collapse
Affiliation(s)
- Esther E J M Creemers
- Department of Pathology, Cardiovascular Research Institute Maastricht, University of Maastricht, The Netherlands
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
31
|
Uemura K, Sugimachi M, Shishido T, Kawada T, Inagaki M, Zheng C, Sato T, Sunagawa K. Convenient automated conductance volumetric system. THE JAPANESE JOURNAL OF PHYSIOLOGY 2002; 52:497-503. [PMID: 12533255 DOI: 10.2170/jjphysiol.52.497] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Conventional conductance volumetric systems require ex-vivo calibrations for blood conductivity and parallel conductance. It is often impractical to repeat blood sampling and hypertonic saline infusion for these calibrations. To overcome these limitations, we developed a useful, self-calibrating conductance volumetric system that does not require ex-vivo calibrations. On a conventional 6-electrode catheter, we added an extra electrode close to one of the recording electrodes to estimate blood conductivity. These two electrodes were placed close (0.5 mm) enough so that conductance between them reflected only blood conductivity regardless of cardiac volume. We estimated parallel conductance by the dual-frequency excitation (2 and 20 kHz) method. In 18 anesthetized rabbits, blood conductivity (sigma(est)) thus estimated agreed well with that (sigma(conv)) measured by the conventional ex-vivo blood sampling method (sigma(est) = 1.04sigma(conv)-0.25, R(2) = 0.98, SEE = 0.01 mS/cm, 1.2% error). Parallel conductance (G(p est)) estimated by dual-frequency excitation also agreed well with that (G(p conv)) estimated by the saline injection method (G(p est) = 0.95G(p conv)+4.25, R(2) = 0.87, SEE = 4.0 mS, 6.0% error). Estimated ventricular volume (V(est)) by our system agreed reasonably well with that (V(conv)) by the conventional method (V(est) = 0.93V(conv)+0.01, R(2) = 0.86, SEE = 0.22 ml, 14.7% error). The fact that this self-calibrating conductance volumetric system drastically simplifies volume measurement makes it an attractive tool for the assessment of cardiac function where significant changes in blood conductivity and parallel conductance are inevitable, such as in cardiac surgery.
Collapse
Affiliation(s)
- Kazunori Uemura
- Department of Cardiovascular Dynamics, National Cardiovascular Center Research Institute, Suita, 565-8565 Japan
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Lorenz JN. A practical guide to evaluating cardiovascular, renal, and pulmonary function in mice. Am J Physiol Regul Integr Comp Physiol 2002; 282:R1565-82. [PMID: 12010737 DOI: 10.1152/ajpregu.00759.2001] [Citation(s) in RCA: 79] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The development and widespread use of genetically altered mice to study the role of various proteins in biological control systems have led to a renewed interest in methodologies and approaches for evaluating physiological phenotypes. As a result, cross-disciplinary approaches have become essential for fully realizing the potential of these new and powerful animal models. The combination of classical physiological approaches and modern innovative technology has given rise to an impressive arsenal for evaluating the functional results of genetic manipulation in the mouse. This review attempts to summarize some of the techniques currently being used for measuring cardiovascular, renal, and pulmonary variables in the intact mouse, with specific attention to practical considerations useful for their successful implementation.
Collapse
Affiliation(s)
- John N Lorenz
- Department of Molecular and Cellular Physiology, University of Cincinnati, Cincinnati, Ohio 45267, USA.
| |
Collapse
|
33
|
Janssen B, Debets J, Leenders P, Smits J. Chronic measurement of cardiac output in conscious mice. Am J Physiol Regul Integr Comp Physiol 2002; 282:R928-35. [PMID: 11832416 DOI: 10.1152/ajpregu.00406.2001] [Citation(s) in RCA: 77] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We describe the feasibility of chronic measurement of cardiac output (CO) in conscious mice. With the use of gas anesthesia, mice >30 g body wt were instrumented either with transit-time flow probes or electromagnetic probes placed on the ascending aorta. Ascending aortic flow values were recorded 6-16 days after surgery when probes had fully grown in. In the first set of experiments, while mice were under ketamine-xylazine anesthesia, estimates of stroke volume (SV) obtained by the transit-time technique were compared with those simultaneously obtained by echocardiography. Transit-time values of SV were similar to those obtained by echocardiography. The average difference +/- SD between the methods was 2 +/- 7 microl. In the second set of studies, transit-time values of CO were compared with those obtained by the electromagnetic flow probes. In conscious resting conditions, estimates +/- SD) of cardiac index (CI) obtained by the transit-time and electromagnetic flow probes were 484 +/- 119 and 531 +/- 103 ml x min(-1) x kg body wt(-1), respectively. Transit-time flow probes were also implanted in mice with a myocardial infarction (MI) induced by ligation of a coronary artery 3 wk before probe implantation. In these MI mice (n = 7), average (+/- SD) resting and stimulated (by volume loading) values of CO were significantly lower than in noninfarcted mice (n = 15) (resting CO 16 +/- 3 vs. 20 +/- 4 ml/min; stimulated CO 20 +/- 5 vs. 26 +/- 6 ml/min). Finally, using transfer function analysis, we found that, in resting conditions for both intact and MI mice, spontaneous variations in CO (> 0.1 Hz) were mainly due to those occurring in SV rather than in heart rate. These data indicate that CO can be measured chronically and reliably in conscious mice, also in conditions of heart failure, and that variations in preload are an important determinant of CO in this species.
Collapse
Affiliation(s)
- B Janssen
- Department of Pharmacology and Toxicology, Cardiovascular Research Institute Maastricht, Universiteit Maastricht, Maastricht, 6200 MD, The Netherlands.
| | | | | | | |
Collapse
|