1
|
Poelmann RE, Gittenberger-de Groot AC, Goerdajal C, Grewal N, De Bakker MAG, Richardson MK. Ventricular Septation and Outflow Tract Development in Crocodilians Result in Two Aortas with Bicuspid Semilunar Valves. J Cardiovasc Dev Dis 2021; 8:jcdd8100132. [PMID: 34677201 PMCID: PMC8537894 DOI: 10.3390/jcdd8100132] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/14/2021] [Accepted: 09/27/2021] [Indexed: 02/07/2023] Open
Abstract
Background: The outflow tract of crocodilians resembles that of birds and mammals as ventricular septation is complete. The arterial anatomy, however, presents with a pulmonary trunk originating from the right ventricular cavum, and two aortas originating from either the right or left ventricular cavity. Mixing of blood in crocodilians cannot occur at the ventricular level as in other reptiles but instead takes place at the aortic root level by a shunt, the foramen of Panizza, the opening of which is guarded by two facing semilunar leaflets of both bicuspid aortic valves. Methods: Developmental stages of Alligator mississipiensis, Crocodilus niloticus and Caiman latirostris were studied histologically. Results and Conclusions: The outflow tract septation complex can be divided into two components. The aorto-pulmonary septum divides the pulmonary trunk from both aortas, whereas the interaortic septum divides the systemic from the visceral aorta. Neural crest cells are most likely involved in the formation of both components. Remodeling of the endocardial cushions and both septa results in the formation of bicuspid valves in all three arterial trunks. The foramen of Panizza originates intracardially as a channel in the septal endocardial cushion.
Collapse
Affiliation(s)
- Robert E. Poelmann
- Sylvius Laboratory, Department of Animal Sciences and Health, Institute of Biology, University of Leiden, Sylvi-usweg 72, 2333BE Leiden, The Netherlands; (C.G.); (M.A.G.D.B.); (M.K.R.)
- Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300RC Leiden, The Netherlands;
- Correspondence: ; Tel.: +31-652695875
| | | | - Charissa Goerdajal
- Sylvius Laboratory, Department of Animal Sciences and Health, Institute of Biology, University of Leiden, Sylvi-usweg 72, 2333BE Leiden, The Netherlands; (C.G.); (M.A.G.D.B.); (M.K.R.)
| | - Nimrat Grewal
- Department of Cardiothoracic Surgery, Leiden University Medical Center, Albinusdreef 2, P.O. Box 9600, 2300RC Leiden, The Netherlands;
| | - Merijn A. G. De Bakker
- Sylvius Laboratory, Department of Animal Sciences and Health, Institute of Biology, University of Leiden, Sylvi-usweg 72, 2333BE Leiden, The Netherlands; (C.G.); (M.A.G.D.B.); (M.K.R.)
| | - Michael K. Richardson
- Sylvius Laboratory, Department of Animal Sciences and Health, Institute of Biology, University of Leiden, Sylvi-usweg 72, 2333BE Leiden, The Netherlands; (C.G.); (M.A.G.D.B.); (M.K.R.)
| |
Collapse
|
2
|
de Oliveira Lima M, Nóbrega YC, de Deus Santos MR, de Carvalho Nunes L, Figueiredo RG, da Silva MA. Notes on the gross anatomy of the heart of the broad-snouted caiman, Caiman latirostris (Daudin, 1802). Anat Histol Embryol 2020; 50:350-359. [PMID: 33249637 DOI: 10.1111/ahe.12636] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Revised: 10/19/2020] [Accepted: 11/11/2020] [Indexed: 11/27/2022]
Abstract
The broad-snouted caiman, Caiman latirostris (Daudin, 1802), is one of the six crocodilian species from Brazil. The topography, morphology and morphometry of the broad-snouted caiman heart were studied. Data were obtained from the necropsy of four adult animals, three females and one male. The hearts were removed from the coelomic cavity and fixed in 10% formalin for 48 hr for morphological and morphometric description. The heart is in the cranial mediastinum. It is caudally involved by the liver cranial margins, and ventrally by the ribs, intercostal muscles, and sternum and dorsally by the lungs. The four-chambered morphology is typical with two (right and left) atria and ventricles. Right and left aortic, pulmonary and subclavian arteries branch from the truncus arteriosus. Gubernaculum cordis is present as ligamentous folds uniting the heart apex to the pericardium. Main morphometric means are the apex-to-base length (49.86 mm), circumference (105.25 mm) and heart weight (45.03 g). The right atrium is craniocaudally longer with thicker walls, whereas the left ventricle is narrower. The topography, morphology and morphometry of the heart of C. latirostris are consistent with the anatomy of other crocodilian species.
Collapse
Affiliation(s)
| | - Yhuri Cardoso Nóbrega
- Instituto Marcos Daniel, Projeto Caiman, Vitória, Brazil.,Programa de pós-graduação em Ecologia de Ecossistemas, Universidade Vila Velha, Vila Velha, Brazil.,Departamento de Medicina Veterinária, Centro Universitário FAESA, Vitória, Brazil
| | | | | | | | | |
Collapse
|
3
|
Conner JL, Crossley JL, Elsey R, Nelson D, Wang T, Crossley DA. Does the left aorta provide proton-rich blood to the gut when crocodilians digest a meal? ACTA ACUST UNITED AC 2019; 222:jeb.201079. [PMID: 30787137 DOI: 10.1242/jeb.201079] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Accepted: 02/15/2019] [Indexed: 11/20/2022]
Abstract
Reptiles have the capacity to differentially perfuse the systemic and pulmonary vascular circuits via autonomic regulation of the heart and the vascular trees. While this aptitude is widely recognized, the role of 'shunting' as a homeostatic mechanism to match convective transport with tissue demand remains unknown. In crocodilians, it has been hypothesized that a pulmonary vascular bypass of systemic venous blood - a right-to-left (R-L) shunt - serves to deliver CO2-rich blood with protons needed for gastric acid secretion during digestion. This hypothesis is partially based on the unique crocodilian vascular anatomy where a left aorta (LAo) arises from the right ventricle, and appears to preferentially supply the gastrointestinal system, whereas the right aorta emerges from the left ventricle. Recent theoretical considerations imply that a R-L shunt would have minuscule effects on P CO2 , but direct measurements of blood gases in both the right and left aortae or both the right and left atria in fed animals have not been conducted. For this reason, we measured blood parameters including P O2 , P CO2 , pHe and [HCO3 -] in the right and left aortae and atria following ingestion of a gavage-fed standardized meal (5% body mass). Blood samples were taken at 3, 6, 12, 24, 36 and 48 h into the digestive period to encompass the period of maximal gastric acid secretion. At no point did P CO2 or pH differ between the left and right aortae, whereas P O2 was significantly lower in the left aorta at several time points during digestion. Our findings do not support the hypothesis that a R-L shunt serves to deliver CO2 for the gastrointestinal system after feeding in crocodilians.
Collapse
Affiliation(s)
- Justin L Conner
- Department of Biological Sciences, University of North Texas, Denton, TX 76203, USA
| | - Janna L Crossley
- Department of Biological Sciences, University of North Texas, Denton, TX 76203, USA
| | - Ruth Elsey
- Department of Wildlife and Fisheries, Grand Chenier, LA 70603, USA
| | - Derek Nelson
- Department of Biological Sciences, University of North Texas, Denton, TX 76203, USA
| | - Tobias Wang
- Zoophysiology, Department of Bioscience, Aarhus University, 8000 Aarhus C, Denmark
| | - Dane A Crossley
- Department of Biological Sciences, University of North Texas, Denton, TX 76203, USA
| |
Collapse
|
4
|
Young BA, Adams J, Segal S, Kondrashova T. Hemodynamics of tonic immobility in the American alligator (Alligator mississippiensis) identified through Doppler ultrasonography. J Comp Physiol A Neuroethol Sens Neural Behav Physiol 2018; 204:953-964. [PMID: 30259097 DOI: 10.1007/s00359-018-1293-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Revised: 09/11/2018] [Accepted: 09/21/2018] [Indexed: 11/28/2022]
Abstract
American alligators (Alligator mississippiensis) held inverted exhibit tonic immobility, combining unresponsiveness with flaccid paralysis. We hypothesize that inverting the alligator causes a gravitationally promoted increase in right aortic blood flowing through the foramen of Panizza, with a concurrent decrease in blood flow through the primary carotid, and thereby of cerebral perfusion. Inverting the alligator results in displacement of the liver, post-pulmonary septum, and the heart. EKG analysis revealed a significant decrease in heart rate following inversion; this decrease was maintained for approximately 45 s after inversion which is in general agreement with the total duration of tonic immobility in alligators (49 s). Doppler ultrasonography revealed that following inversion of the alligator, there was a reversal in direction of blood flow through the foramen of Panizza, and this blood flow had a significant increase in velocity (compared to the foraminal flow in the prone alligator). There was an associated significant decrease in the velocity of blood flow through the primary carotid artery once the alligator was held in the supine position. Tonic immobility in the alligator appears to be a form of vasovagal syncope which arises, in part, from the unique features of the crocodilian heart.
Collapse
Affiliation(s)
- Bruce A Young
- Department of Anatomy, Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, MO, 63501, USA.
| | - James Adams
- Department of Anatomy, Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, MO, 63501, USA
| | - Solomon Segal
- Department of Anatomy, Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, MO, 63501, USA
| | - Tatyana Kondrashova
- Department of Family Medicine, Preventitive Medicine, and Community Health, Kirksville College of Osteopathic Medicine, A.T. Still University, Kirksville, MO, 63501, USA
| |
Collapse
|
5
|
The effects of embryonic hypoxic programming on cardiovascular function and autonomic regulation in the American alligator (Alligator mississippiensis) at rest and during swimming. J Comp Physiol B 2018; 188:967-976. [DOI: 10.1007/s00360-018-1181-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 08/25/2018] [Accepted: 09/06/2018] [Indexed: 02/08/2023]
|
6
|
Stegmann GF, Williams CJA, Franklin C, Wang T, Axelsson M. Long-term surgical anaesthesia with isoflurane in human habituated Nile Crocodiles. J S Afr Vet Assoc 2017; 88:e1-e6. [PMID: 28281769 PMCID: PMC6138134 DOI: 10.4102/jsava.v88i0.1451] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Revised: 11/21/2016] [Accepted: 12/08/2016] [Indexed: 12/04/2022] Open
Abstract
A suitable long-term anaesthetic technique was required for implantation of physiological sensors and telemetric devices in sub-adult Nile crocodiles (Crocodylus niloticus) to allow the collection of physiological data. Five Nile crocodiles with a median body mass of 24 kg were used. After manual capture, they were blindfolded and 0.2 mL (1 mg/mL) medetomidine was administered intramuscularly in four of the animals which had an estimated body mass between 20 kg and 30 kg. One crocodile with an estimated body mass of 50 kg received 0.5 mL. For induction, 5 mL propofol (10 mg/mL) was injected intravenously into the occipital sinus. Additional doses were given when required to ensure adequate anaesthesia. Anaesthesia was maintained with 1.5% isoflurane. Ventilation was controlled. Local anaesthesia was administered for surgical incision and external placement of the radio transmitter. Medetomidine was antagonised with atipamezole at the end of surgery. Median heart rate during surgery was 22 beats/min, at extubation 32 beats per min and 30 beats per min the following day at the same body temperature as under anaesthesia. Median body temperature of the animals increased from 27.3 °C to 27.9 °C during anaesthesia, as room temperature increased from 24.5 °C to 29.0 °C during surgery. Anaesthesia was successfully induced with intramuscular medetomidine and intravenous propofol and was maintained with isoflurane for the placement of telemetric implants. Intraoperative analgesia was supplemented with lidocaine infiltration. Perioperative physiological parameters remained stable and within acceptable clinical limits. Multiple factors appear to influence these variables during the recovery period, including residual anaesthetic effects, environmental temperature and physical activity.
Collapse
Affiliation(s)
- George F Stegmann
- Department of Companion Animal Clinical Studies, University of Pretoria.
| | | | | | | | | |
Collapse
|
7
|
Yigit B, Pekkan K. Non-dimensional physics of pulsatile cardiovascular networks and energy efficiency. J R Soc Interface 2016; 13:20151019. [PMID: 26819334 PMCID: PMC4759807 DOI: 10.1098/rsif.2015.1019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 01/04/2016] [Indexed: 11/12/2022] Open
Abstract
In Nature, there exist a variety of cardiovascular circulation networks in which the energetic ventricular load has both steady and pulsatile components. Steady load is related to the mean cardiac output (CO) and the haemodynamic resistance of the peripheral vascular system. On the other hand, the pulsatile load is determined by the simultaneous pressure and flow waveforms at the ventricular outlet, which in turn are governed through arterial wave dynamics (transmission) and pulse decay characteristics (windkessel effect). Both the steady and pulsatile contributions of the haemodynamic power load are critical for characterizing/comparing disease states and for predicting the performance of cardiovascular devices. However, haemodynamic performance parameters vary significantly from subject to subject because of body size, heart rate and subject-specific CO. Therefore, a 'normalized' energy dissipation index, as a function of the 'non-dimensional' physical parameters that govern the circulation networks, is needed for comparative/integrative biological studies and clinical decision-making. In this paper, a complete network-independent non-dimensional formulation that incorporates pulsatile flow regimes is developed. Mechanical design variables of cardiovascular flow systems are identified and the Buckingham Pi theorem is formally applied to obtain the corresponding non-dimensional scaling parameter sets. Two scaling approaches are considered to address both the lumped parameter networks and the distributed circulation components. The validity of these non-dimensional number sets is tested extensively through the existing empirical allometric scaling laws of circulation systems. Additional validation studies are performed using a parametric numerical arterial model that represents the transmission and windkessel characteristics, which are adjusted to represent different body sizes and non-dimensional haemodynamic states. Simulations demonstrate that the proposed non-dimensional indices are independent of body size for healthy conditions, but are sensitive to deviations caused by off-design disease states that alter the energetic load. Sensitivity simulations are used to identify the relationship between pulsatile power loss and non-dimensional characteristics, and optimal operational states are computed.
Collapse
Affiliation(s)
- Berk Yigit
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Kerem Pekkan
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA Department of Mechanical Engineering, Koç University, Istanbul, Turkey
| |
Collapse
|
8
|
Eme J, Gwalthney J, Blank JM, Owerkowicz T, Barron G, Hicks JW. Surgical removal of right-to-left cardiac shunt in the American alligator (Alligator mississippiensis) causes ventricular enlargement but does not alter apnoea or metabolism during diving. ACTA ACUST UNITED AC 2010; 212:3553-63. [PMID: 19837897 DOI: 10.1242/jeb.034595] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Crocodilians have complete anatomical separation between the ventricles, similar to birds and mammals, but retain the dual aortic arch system found in all non-avian reptiles. This cardiac anatomy allows surgical modification that prevents right-to-left (R-L) cardiac shunt. A R-L shunt is a bypass of the pulmonary circulation and recirculation of oxygen-poor blood back to the systemic circulation and has often been observed during the frequent apnoeic periods of non-avian reptiles, particularly during diving in aquatic species. We eliminated R-L shunt in American alligators (Alligator mississippiensis) by surgically occluding the left aorta (LAo; arising from right ventricle) upstream and downstream of the foramen of Panizza (FoP), and we tested the hypotheses that this removal of R-L shunt would cause afterload-induced cardiac remodelling and adversely affect diving performance. Occlusion of the LAo both upstream and downstream of the FoP for approximately 21 months caused a doubling of RV pressure and significant ventricular enlargement (average approximately 65%) compared with age-matched, sham-operated animals. In a separate group of recovered, surgically altered alligators allowed to dive freely in a dive chamber at 23 degrees C, occlusion of the LAo did not alter oxygen consumption or voluntary apnoeic periods relative to sham animals. While surgical removal of R-L shunt causes considerable changes in cardiac morphology similar to aortic banding in mammals, its removal does not affect the respiratory pattern or metabolism of alligators. It appears probable that the low metabolic rate of reptiles, rather than pulmonary circulatory bypass, allows for normal aerobic dives.
Collapse
Affiliation(s)
- John Eme
- Ecology and Evolutionary Biology, University of California, Irvine, 321 Steinhaus Hall, Irvine, CA 92697-2525, USA.
| | | | | | | | | | | |
Collapse
|
9
|
Axelsson M, Dang Q, Pitsillides K, Munns S, Hicks J, Kassab GS. A novel, fully implantable, multichannel biotelemetry system for measurement of blood flow, pressure, ECG, and temperature. J Appl Physiol (1985) 2006; 102:1220-8. [PMID: 17122378 DOI: 10.1152/japplphysiol.00887.2006] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Biotelemetry provides high-quality data in awake, free-ranging animals without the effects of anesthesia and surgery. Although many biological parameters can be measured using biotelemetry, simultaneous telemetric measurements of pressure and flow have not been available. The objective of this study was to evaluate simultaneous measurements of blood flow, pressure, ECG, and temperature in a fully implantable system. This novel system allows the measurement of up to four channels of blood flow, up to three channels of pressure, and a single channel each of ECG and temperature. The system includes a bidirectional radio-frequency link that allows the implant to send data and accept commands to perform various tasks. The system is controlled by a base station decoder/controller that decodes the data stream sent by the implant into analog signals. The system also converts the data into a digital data stream that can be sent via ethernet to a remote computer for storage and/or analysis. The system was chronically implanted in swine and alligators for up to 5 wk. Both bench and in vivo animal tests were performed to evaluate system performance. Results show that this biotelemetry system is capable of long-term accurate monitoring of simultaneous blood flow and pressure. The system allows, within the room, recordings, since the implant transmission range is between 6 and 10 m, and, with a relay, backpack transmission distance of up to 500 m can be achieved. This system will have significant utility in chronic models of cardiovascular physiology and pathology.
Collapse
Affiliation(s)
- M Axelsson
- Dept. of Zoology, Göteborg University, Sweden
| | | | | | | | | | | |
Collapse
|
10
|
Hicks JW. The physiological and evolutionary significance of cardiovascular shunting patterns in reptiles. Physiology (Bethesda) 2002; 17:241-5. [PMID: 12433978 DOI: 10.1152/nips.01397.2002] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The morphology of the reptilian heart results in the mixing of oxygenated and deoxygenated blood (cardiac shunts). In birds and mammals cardiac shunts are detrimental, but in reptiles this condition is often considered a derived trait, conveying important physiological functions and favored by natural selection. Alternative views are advanced suggesting that, in reptiles, cardiac shunts represent either an ancestral condition or an embryonic trait.
Collapse
Affiliation(s)
- James W Hicks
- Department of Ecology and Evolutionary Biology, University of California at Irvine, 92697, USA
| |
Collapse
|
11
|
Syme DA, Gamperl K, Jones DR. Delayed depolarization of the cog-wheel valve and pulmonary-to-systemic shunting in alligators. J Exp Biol 2002; 205:1843-51. [PMID: 12077160 DOI: 10.1242/jeb.205.13.1843] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
SUMMARYAlligators and other crocodilians have a cog-wheel valve located within the subpulmonary conus, and active closure of this valve during each heart beat can markedly and phasically increase resistance in the pulmonary outflow tract. If this increased resistance causes right ventricular pressure to rise above that in the systemic circuit, right ventricular blood can flow into the left aorta and systemic circulation, an event known as pulmonary-to-systemic shunting. To understand better how this valve is controlled, anaesthetized American alligators (Alligator mississippiensis) were used to examine the relationships between depolarization of the right ventricle,depolarization/contraction of the cog-wheel valve muscle and the resultant right ventricular, pulmonary artery and systemic pressures. Depolarization swept across the right ventricle from the apex towards the base (near where the cog-wheel valve muscle is located) at a velocity of 91±23 cm s-1 (mean ± S.E.M., N=3). The cog-wheel valve electrocardiogram (ECG) (and thus contraction of the valve) trailed the right ventricular ECG by 248±28 ms (N=3), which was equivalent to 6-35 % of a cardiac cycle. This long interval between right ventricular and valve depolarization suggests a nodal delay at the junction between the base of the right ventricle and the cog-wheel valve. The delay before valve closure determined when the abrupt secondary rise in right ventricular pressure occurred during systole and is likely to strongly influence the amount of blood entering the pulmonary artery and thus to directly control the degree of shunting. Left vagal stimulation (10-50 Hz) reduced the conduction delay between the right ventricle and cog-wheel valve by approximately 20 % and reduced the integrated cog-wheel ECG by 10-20 %. Direct application of acetylcholine (1-2 mg) also reduced the integrated cog-wheel ECG by 10-100 %;however, its effect on the conduction delay was highly variable (-40 to +60%). When the cog-wheel valve muscle was killed by the application of ethanol,the cog-wheel ECG was absent, right ventricular and pulmonary pressures remained low and tracked one another, the secondary rise in right ventricular pressure was abolished and shunting did not occur. This study provides additional, direct evidence that phasic contraction of the cog-wheel valve muscle controls shunting, that nervous and cholinergic stimulation can alter the delay and strength of valve depolarization and that this can affect the propensity to shunt.
Collapse
Affiliation(s)
- Douglas A Syme
- Department of Biological Sciences, 2500 University Drive NW, University of Calgary, Calgary, Alberta, Canada T2N 1N4.
| | | | | |
Collapse
|