1
|
Dresvyanina EN, Tagandurdyyeva NA, Kodolova-Chukhontseva VV, Dobrovol'skaya IP, Kamalov AM, Nashchekina YA, Nashchekin AV, Ivanov AG, Yukina GY, Yudin VE. Structure and Properties of Composite Fibers Based on Chitosan and Single-Walled Carbon Nanotubes for Peripheral Nerve Regeneration. Polymers (Basel) 2023; 15:2860. [PMID: 37447506 DOI: 10.3390/polym15132860] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 06/19/2023] [Accepted: 06/21/2023] [Indexed: 07/15/2023] Open
Abstract
This study focused on a potential application of electrically conductive, biocompatible, bioresorbable fibers for tubular conduits aimed at the regeneration of peripheral nerves. The conducting, mechanical, and biological properties of composite fibers based on chitosan and single-walled carbon nanotubes were investigated in this paper. It was shown that introducing 0.5 wt.% of SWCNT into the composite fibers facilitated the formation of a denser fiber structure, resulting in improved strength (σ = 260 MPa) and elastic (E = 14 GPa) characteristics. Additionally, the composite fibers were found to be biocompatible and did not cause significant inflammation or deformation during in vivo studies. A thin layer of connective tissue formed around the fiber.
Collapse
Affiliation(s)
- Elena N Dresvyanina
- Institute of Textile and Fashion, Saint Petersburg State University of Industrial Technologies and Design, B. Morskaya Str., 18, Saint Petersburg 191186, Russia
| | - Nurjemal A Tagandurdyyeva
- Institute of Biomedical Systems and Biotechnology, Peter the Great Saint Petersburg Polytechnic University, Polytekhnicheskaya Str., 29, Saint Petersburg 195251, Russia
| | - Vera V Kodolova-Chukhontseva
- Institute of Biomedical Systems and Biotechnology, Peter the Great Saint Petersburg Polytechnic University, Polytekhnicheskaya Str., 29, Saint Petersburg 195251, Russia
- Institute of Macromolecular Compounds of Russian Academy of Sciences, VO Bolshoy pr., 31, Saint Petersburg 199004, Russia
| | - Irina P Dobrovol'skaya
- Institute of Macromolecular Compounds of Russian Academy of Sciences, VO Bolshoy pr., 31, Saint Petersburg 199004, Russia
| | - Almaz M Kamalov
- Institute of Biomedical Systems and Biotechnology, Peter the Great Saint Petersburg Polytechnic University, Polytekhnicheskaya Str., 29, Saint Petersburg 195251, Russia
| | - Yulia A Nashchekina
- Institute of Cytology Russian Academy of Sciences, Tikhoretsky Ave., 4, Saint Petersburg 194064, Russia
| | - Alexey V Nashchekin
- Ioffe Institute, Polytekhnicheskaya Str., 26, Saint Petersburg 194021, Russia
| | - Alexey G Ivanov
- Institute of Macromolecular Compounds of Russian Academy of Sciences, VO Bolshoy pr., 31, Saint Petersburg 199004, Russia
| | - Galina Yu Yukina
- Pavlov First Saint Petersburg State Medical University, L'va Tolstogo Str. 6-8, Saint Petersburg 197022, Russia
| | - Vladimir E Yudin
- Institute of Macromolecular Compounds of Russian Academy of Sciences, VO Bolshoy pr., 31, Saint Petersburg 199004, Russia
| |
Collapse
|
2
|
Heterogeneous porous PLLA/PCL fibrous scaffold for bone tissue regeneration. Int J Biol Macromol 2023; 235:123781. [PMID: 36849071 DOI: 10.1016/j.ijbiomac.2023.123781] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 02/09/2023] [Accepted: 02/16/2023] [Indexed: 02/27/2023]
Abstract
Bone tissue engineering has become one of the most promising therapeutic methods to treat bone defects. A suitable scaffolding material to regenerate new bone tissues should have a high specific surface area, high porosity and a suitable surface structure which benefit cell attachment, proliferation, and differentiation. In this study, an acetone post-treatment strategy was developed to generate heterogeneous structure. After PLLA/PCL nanofibrous membranes were electrospun and collected, they were treated with acetone to generate a highly porous structure. Meanwhile, part of PCL was extracted from the fibre and enriched on the fibre surface. The cell affinity of the nanofibrous membrane was verified by human osteoblast-like cells assay. The proliferation rate of heterogeneous samples increased 190.4 %, 265.5 % and 137.9 % at day 10 compared with pristine samples. These results demonstrated that the heterogeneous PLLA/PCL nanofibrous membranes could enhance osteoblast adhesion and proliferation. With high surface area (average surface area 36.302 m2/g) and good mechanical properties (average Young's modulus 1.65 GPa and average tensile strength 5.1 MPa), the heterogeneous PLLA/PCL membrane should have potential applications in the field of bone regeneration.
Collapse
|
3
|
Zia AW, Liu R, Wu X. Structural design and mechanical performance of composite vascular grafts. Biodes Manuf 2022. [DOI: 10.1007/s42242-022-00201-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
AbstractThis study reviews the state of the art in structural design and the corresponding mechanical behaviours of composite vascular grafts. We critically analyse surface and matrix designs composed of layered, embedded, and hybrid structures along the radial and longitudinal directions; materials and manufacturing techniques, such as tissue engineering and the use of textiles or their combinations; and the corresponding mechanical behaviours of composite vascular grafts in terms of their physical–mechanical properties, especially their stress–strain relationships and elastic recovery. The role of computational studies is discussed with respect to optimizing the geometrics designs and the corresponding mechanical behaviours to satisfy specialized applications, such as those for the aorta and its subparts. Natural and synthetic endothelial materials yield improvements in the mechanical and biological compliance of composite graft surfaces with host arteries. Moreover, the diameter, wall thickness, stiffness, compliance, tensile strength, elasticity, and burst strength of the graft matrix are determined depending on the application and the patient. For composite vascular grafts, hybrid architectures are recommended featuring multiple layers, dimensions, and materials to achieve the desired optimal flexibility and function for complying with user-specific requirements. Rapidly emerging artificial intelligence and big data techniques for diagnostics and the three-dimensional (3D) manufacturing of vascular grafts will likely yield highly compliant, subject-specific, long-lasting, and economical vascular grafts in the near-future.
Graphic abstract
Collapse
|
4
|
Chiriateva AE, Zavrazhnykh NA, Popryadukhin PV, Yukina GY, Kriventsov AV, Ivankova EM, Yudin VE. Small Diameter Nonwoven Vascular Prostheses Based on Aromatic Polyimide Nanofibers. Biophysics (Nagoya-shi) 2022. [DOI: 10.1134/s0006350922040054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
5
|
Lequeux A, Maze B, Laroche G, Heim F. Non-woven textiles for medical implants: mechanical performances improvement. BIOMED ENG-BIOMED TE 2022; 67:317-330. [PMID: 35611716 DOI: 10.1515/bmt-2022-0017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 05/03/2022] [Indexed: 11/15/2022]
Abstract
Non-woven textile has been largely used as medical implant material over the last decades, especially for scaffold manufacturing purpose. This material presents a large surface area-to-volume ratio, which promotes adequate interaction with biological tissues. However, its strength is limited due to the lack of cohesion between the fibers. The goal of the present work was to investigate if a non-woven substrate can be reinforced by embroidery stitching towards strength increase. Non-woven samples were produced from both melt-blowing and electro-spinning techniques, reinforced with a stitching yarn and tested regarding several performances: ultimate tensile strength, burst strength and strength loss after fatigue stress. Several stitching parameters were considered: distance between stitches, number of stitch lines (1, 2 or 3) and line geometry (horizontal H, vertical L, cross X). The performance values obtained after reinforcement were compared with values obtained for control samples. Results bring out that reinforcement can increase the strength by up to 50% for a melt-blown mat and by up to 100% for an electro-spun mat with an X reinforcement pattern. However, after cyclic loading, the reinforcement yarn tends to degrade the ES mat in particular. Moreover, increasing the number of stitches tends to fragilize the mats.
Collapse
Affiliation(s)
- Amandine Lequeux
- Laboratoire de Physique et Mécanique Textiles (LPMT), ENSISA, Mulhouse, France
| | - Benoit Maze
- The Nonwovens Institute, North Carolina State University, Raleigh, NC, USA
| | - Gaetan Laroche
- Département de Génie des Mines, de la Métallurgie et des Matériaux, Laboratoire d'Ingénierie de Surface, Centre de Recherche sur les Matériaux Avancés, Université Laval, Québec, Canada
- Centre de Recherche du Centre Hospitalier Universitaire de Québec, Hôpital St-François d'Assise, Québec, Canada
| | - Frederic Heim
- Laboratoire de Physique et Mécanique Textiles (LPMT), ENSISA, Mulhouse, France
- Geprovas, Strasbourg, France
| |
Collapse
|
6
|
Thottappillil N, Nair PD. Dual source co-electrospun tubular scaffold generated from gelatin-vinyl acetate and poly-ɛ-caprolactone for smooth muscle cell mediated blood vessel engineering. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 114:111030. [PMID: 32994010 DOI: 10.1016/j.msec.2020.111030] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 04/09/2020] [Accepted: 04/27/2020] [Indexed: 01/01/2023]
Affiliation(s)
- Neelima Thottappillil
- Division of Tissue Engineering and Regeneration Technologies, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram 695012, India
| | - Prabha D Nair
- Division of Tissue Engineering and Regeneration Technologies, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Thiruvananthapuram 695012, India.
| |
Collapse
|
7
|
Dobrovol’skaya IP, Zavrazhnykh NA, Popryadukhin PV, Kasatkin IA, Popova EN, Ivan’kova EM, Saprykina NN, Yudin VE. Structure and Thermomechanical Properties of Tubes Based on Poly(L-lactide) Microfibers. POLYMER SCIENCE SERIES A 2020. [DOI: 10.1134/s0965545x20040057] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
8
|
Colazo JM, Evans BC, Farinas AF, Al-Kassis S, Duvall CL, Thayer WP. Applied Bioengineering in Tissue Reconstruction, Replacement, and Regeneration. TISSUE ENGINEERING PART B-REVIEWS 2020; 25:259-290. [PMID: 30896342 DOI: 10.1089/ten.teb.2018.0325] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
IMPACT STATEMENT The use of autologous tissue in the reconstruction of tissue defects has been the gold standard. However, current standards still face many limitations and complications. Improving patient outcomes and quality of life by addressing these barriers remain imperative. This article provides historical perspective, covers the major limitations of current standards of care, and reviews recent advances and future prospects in applied bioengineering in the context of tissue reconstruction, replacement, and regeneration.
Collapse
Affiliation(s)
- Juan M Colazo
- 1Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, Tennessee.,2Medical Scientist Training Program, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Brian C Evans
- 3Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Angel F Farinas
- 4Department of Plastic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Salam Al-Kassis
- 4Department of Plastic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| | - Craig L Duvall
- 3Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee
| | - Wesley P Thayer
- 3Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee.,4Department of Plastic Surgery, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
9
|
Jana S. Endothelialization of cardiovascular devices. Acta Biomater 2019; 99:53-71. [PMID: 31454565 DOI: 10.1016/j.actbio.2019.08.042] [Citation(s) in RCA: 74] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 07/19/2019] [Accepted: 08/22/2019] [Indexed: 01/10/2023]
Abstract
Blood-contacting surfaces of cardiovascular devices are not biocompatible for creating an endothelial layer on them. Numerous research studies have mainly sought to modify these surfaces through physical, chemical and biological means to ease early endothelial cell (EC) adhesion, migration and proliferation, and eventually to build an endothelial layer on the surfaces. The first priority for surface modification is inhibition of protein adsorption that leads to inhibition of platelet adhesion to the device surfaces, which may favor EC adhesion. Surface modification through surface texturing, if applicable, can bring some hopeful outcomes in this regard. Surface modifications through chemical and/or biological means may play a significant role in easy endothelialization of cardiovascular devices and inhibit smooth muscle cell proliferation. Cellular engineering of cells relevant to endothelialization can boost the positive outcomes obtained through surface engineering. This review briefly summarizes recent developments and research in early endothelialization of cardiovascular devices. STATEMENT OF SIGNIFICANCE: Endothelialization of cardiovascular implants, including heart valves, vascular stents and vascular grafts is crucial to solve many problems in our health care system. Numerous research efforts have been made to improve endothelialization on the surfaces of cardiovascular implants, mainly through surface modifications in three ways - physically, chemically and biologically. This review is intended to highlight comprehensive research studies to date on surface modifications aiming for early endothelialization on the blood-contacting surfaces of cardiovascular implants. It also discusses future perspectives to help guide endothelialization strategies and inspire further innovations.
Collapse
Affiliation(s)
- Soumen Jana
- Department of Bioengineering, University of Missouri, Columbia, MO 65211, USA.
| |
Collapse
|
10
|
Chen D, Weng L, Chen C, Zheng J, Wu T, Zeng S, Zhang S, Xiao J. Inflammation and dysfunction in human aortic endothelial cells associated with poly-l-lactic acid degradation in vitro are alleviated by curcumin. J Biomed Mater Res A 2019; 107:2756-2763. [PMID: 31408261 DOI: 10.1002/jbm.a.36778] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 03/14/2019] [Accepted: 08/07/2019] [Indexed: 01/10/2023]
Abstract
Poly-l-lactic acid (PLLA) is widely used in clinic, for example, as biodegradable coronary artery stents. However, inflammatory responses in endothelial cells associated with PLLA degradation are relatively undefined. We previously reported inflammation in human aortic endothelial cells (HAEC) in vitro and in vivo. Here, we further assessed inflammatory injury, including cell migration, cell function, and inflammatory cytokines expressed in HAEC treated with PLLA and curcumin by CCK-8, wound healing assay, ELISA, and Western blot. Significant inhibition of cell migration, remarkable dysfunction, and inflammatory responses were found in HAEC treated with PLLA degradation extract, and these effects were alleviated by Cur treatment. These findings indicated that cautious evaluation of biodegradable polymers should be performed, and Cur represents a promising anti-inflammatory agent for alleviating endothelial dysfunction and inflammation caused by PLLA degradation. In addition, Cur should be further studied experimentally in in vivo experiments on animal models as a potential therapeutic to reduce thrombosis of biodegradable polymer stents.
Collapse
Affiliation(s)
- Dongping Chen
- Central Laboratory, The Dongguan Affiliated Hospital of Medical College of Jinan University, The Fifth People's Hospital of Dongguan, Dongguan, China
| | - Linsheng Weng
- Department of Cardiology, The Dongguan Affiliated Hospital of Medical College of Jinan University, The Fifth People's Hospital of Dongguan, Dongguan, China
| | - Can Chen
- Department of Pathology, The Dongguan Affiliated Hospital of Medical College of Jinan University, The Fifth People's Hospital of Dongguan, Dongguan, China
| | - Jian Zheng
- Dongguan TT Medical, Inc., Dongguan, China
| | - Tim Wu
- Dongguan TT Medical, Inc., Dongguan, China.,Vaso Tech, Inc., Lowell, Massachusetts
| | - Sufen Zeng
- Central Laboratory, The Dongguan Affiliated Hospital of Medical College of Jinan University, The Fifth People's Hospital of Dongguan, Dongguan, China
| | - Suzhen Zhang
- Central Laboratory, The Dongguan Affiliated Hospital of Medical College of Jinan University, The Fifth People's Hospital of Dongguan, Dongguan, China
| | - Jianmin Xiao
- Central Laboratory, The Dongguan Affiliated Hospital of Medical College of Jinan University, The Fifth People's Hospital of Dongguan, Dongguan, China.,Department of Cardiology, The Dongguan Affiliated Hospital of Medical College of Jinan University, The Fifth People's Hospital of Dongguan, Dongguan, China
| |
Collapse
|
11
|
Portillo-Lara R, Spencer AR, Walker BW, Shirzaei Sani E, Annabi N. Biomimetic cardiovascular platforms for in vitro disease modeling and therapeutic validation. Biomaterials 2019; 198:78-94. [PMID: 30201502 PMCID: PMC11044891 DOI: 10.1016/j.biomaterials.2018.08.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 08/02/2018] [Accepted: 08/03/2018] [Indexed: 02/07/2023]
Abstract
Bioengineered tissues have become increasingly more sophisticated owing to recent advancements in the fields of biomaterials, microfabrication, microfluidics, genetic engineering, and stem cell and developmental biology. In the coming years, the ability to engineer artificial constructs that accurately mimic the compositional, architectural, and functional properties of human tissues, will profoundly impact the therapeutic and diagnostic aspects of the healthcare industry. In this regard, bioengineered cardiac tissues are of particular importance due to the extremely limited ability of the myocardium to self-regenerate, as well as the remarkably high mortality associated with cardiovascular diseases worldwide. As novel microphysiological systems make the transition from bench to bedside, their implementation in high throughput drug screening, personalized diagnostics, disease modeling, and targeted therapy validation will bring forth a paradigm shift in the clinical management of cardiovascular diseases. Here, we will review the current state of the art in experimental in vitro platforms for next generation diagnostics and therapy validation. We will describe recent advancements in the development of smart biomaterials, biofabrication techniques, and stem cell engineering, aimed at recapitulating cardiovascular function at the tissue- and organ levels. In addition, integrative and multidisciplinary approaches to engineer biomimetic cardiovascular constructs with unprecedented human and clinical relevance will be discussed. We will comment on the implementation of these platforms in high throughput drug screening, in vitro disease modeling and therapy validation. Lastly, future perspectives will be provided on how these biomimetic platforms will aid in the transition towards patient centered diagnostics, and the development of personalized targeted therapeutics.
Collapse
Affiliation(s)
- Roberto Portillo-Lara
- Department of Chemical Engineering, Northeastern University, Boston, USA; Tecnologico de Monterrey, Escuela de Ingeniería y Ciencias, Zapopan, JAL, Mexico
| | - Andrew R Spencer
- Department of Chemical Engineering, Northeastern University, Boston, USA
| | - Brian W Walker
- Department of Chemical and Biomolecular Engineering, University of California- Los Angeles, Los Angeles, CA 90095, USA
| | - Ehsan Shirzaei Sani
- Department of Chemical and Biomolecular Engineering, University of California- Los Angeles, Los Angeles, CA 90095, USA
| | - Nasim Annabi
- Department of Chemical and Biomolecular Engineering, University of California- Los Angeles, Los Angeles, CA 90095, USA; Center for Minimally Invasive Therapeutics (C-MIT), University of California-Los Angeles, Los Angeles, CA, USA; Harvard-MIT Division of Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, USA.
| |
Collapse
|
12
|
Nguyen TU, Shojaee M, Bashur CA, Kishore V. Electrochemical fabrication of a biomimetic elastin-containing bi-layered scaffold for vascular tissue engineering. Biofabrication 2018; 11:015007. [PMID: 30411718 DOI: 10.1088/1758-5090/aaeab0] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Biomimetic tissue-engineered vascular grafts (TEVGs) have immense potential to replace diseased small-diameter arteries (<4 mm) for the treatment of cardiovascular diseases. However, biomimetic approaches developed thus far only partially recapitulate the physicochemical properties of the native vessel. While it is feasible to fabricate scaffolds that are compositionally similar to native vessels (collagen and insoluble elastic matrix) using freeze-drying, these scaffolds do not mimic the aligned topography of collagen and elastic fibers found in native vessels. Extrusion-based scaffolds exhibit anisotropic collagen orientation but these scaffolds are compositionally dissimilar (cannot incorporate insoluble elastic matrix). In this study, an electrochemical fabrication technique was employed to develop a biomimetic elastin-containing bi-layered collagen scaffold which is compositionally and structurally similar to native vessels and the effect of insoluble elastin incorporation on scaffold mechanics and smooth muscle cell (SMC) response was investigated. Further, the functionality of human umbilical vein endothelial cells (HUVECs) on the scaffold lumen surface was assessed via immunofluorescence. Results showed that incorporation of insoluble elastin maintained the overall collagen alignment within electrochemically aligned collagen (ELAC) fibers and this underlying aligned topography can direct cellular orientation. Ring test results showed that circumferential orientation of ELAC fibers significantly improved scaffold mechanics. Real-time PCR revealed that the expression of α-smooth muscle actin (Acta2) and myosin heavy chain (MyhII) was significantly higher on elastin containing scaffolds suggesting that the presence of insoluble elastin can promote contractility in SMCs. Further, mechanical properties of the scaffolds significantly improved post-culture indicating the presence of a mature cell-synthesized and remodeled matrix. Finally, HUVECs expressed functional markers on collagen lumen scaffolds. In conclusion, electrochemical fabrication is a viable method for the generation of a functional biomimetic TEVG with the potential to be used in bypass surgery.
Collapse
Affiliation(s)
- Thuy-Uyen Nguyen
- Department of Chemical Engineering, Florida Institute of Technology, Melbourne, FL 32901, United States of America
| | | | | | | |
Collapse
|
13
|
Atlan M, Simon-Yarza T, Ino JM, Hunsinger V, Corté L, Ou P, Aid-Launais R, Chaouat M, Letourneur D. Design, characterization and in vivo performance of synthetic 2 mm-diameter vessel grafts made of PVA-gelatin blends. Sci Rep 2018; 8:7417. [PMID: 29743525 PMCID: PMC5943294 DOI: 10.1038/s41598-018-25703-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2017] [Accepted: 04/24/2018] [Indexed: 01/06/2023] Open
Abstract
Since the development of the first vascular grafts, fabrication of vessel replacements with diameters smaller than 6 mm remains a challenge. The present work aimed to develop PVA (poly (vinyl alcohol))-gelatin hybrids as tubes suitable for replacement of very small vessels and to evaluate their performance using a rat abdominal aorta interposition model. PVA-gelatin hybrid tubes with internal and external diameters of 1.4 mm and 1.8 mm, respectively, composed of 4 different gelatin ratios were prepared using a one-step strategy with both chemical and physical crosslinking. By 3D Time of Flight MRI, Doppler-Ultrasound, Computed Tomography angiography and histology, we demonstrated good patency rates with the 1% gelatin composition until the end of the study at 3 months (50% compared to 0% of PVA control grafts). A reduction of the patency rate during the time of implantation suggested some loss of properties of the hybrid material in vivo, further confirmed by mechanical evaluation until one year. In particular, stiffening and reduction of compliance of the PVA-gelatin grafts was demonstrated, which might explain the observed long-term changes in patency rate. These encouraging results confirm the potential of PVA-gelatin hybrids as ready-to-use vascular grafts for very small vessel replacement.
Collapse
Affiliation(s)
- M Atlan
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France. .,Faculty of Medicine, University Pierre et Marie Curie, Plastic Surgery Department, Hôpital Tenon, Paris, France.
| | - T Simon-Yarza
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France.
| | - J M Ino
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France
| | - V Hunsinger
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France.,Faculty of Medicine, University Pierre et Marie Curie, Plastic Surgery Department, Hôpital Tenon, Paris, France
| | - L Corté
- MINES ParisTech, PSL Research University, MAT - Centre des Matériaux, CNRS UMR 7633, BP 87 91003, Evry, France.,ESPCI-Paris, PSL Research University, Matière Molle et Chimie, CNRS UMR 7167, Paris, 75005, France
| | - P Ou
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France
| | - R Aid-Launais
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France.,FRIM, INSERM UMS 034 Paris Diderot University, X. Bichat Hospital, 75018, Paris, France
| | - M Chaouat
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France.,Plastic Surgery Department, Burn Unit, Paris Diderot University, Hôpital Saint Louis, Paris, France
| | - D Letourneur
- INSERM U1148, Laboratory for Vascular Translational Science, X. Bichat Hospital, Paris Diderot University, Paris 13 University, 75018, Paris, France
| |
Collapse
|
14
|
Masuda T, Ukiki M, Yamagishi Y, Matsusaki M, Akashi M, Yokoyama U, Arai F. Fabrication of engineered tubular tissue for small blood vessels via three-dimensional cellular assembly and organization ex vivo. J Biotechnol 2018; 276-277:46-53. [PMID: 29689281 DOI: 10.1016/j.jbiotec.2018.04.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Revised: 03/24/2018] [Accepted: 04/09/2018] [Indexed: 12/31/2022]
Abstract
Although there is a great need for suitable vascular replacements in clinical practice, much progress needs to be made toward the development of a fully functional tissue-engineered construct. We propose a fabrication method of engineered tubular tissue for small blood vessels via a layer-by-layer cellular assembly technique using mouse smooth muscle cells, the construction of a poly-(l-lactide-co-ε-caprolactone) (PLCL) scaffold, and integration in a microfluidic perfusion culture system. The cylindrical PLCL scaffold is incised, expanded, and its surface is laminated with the cell layers. The construct confirms into tubular structures due to residual stress imposed by the cylindrical PLCL scaffold. The perfusion culture system allows simulation of static, perfusion (laminar flow), and perfusion with pulsatile pressure (Pulsatile flow) conditions in which mimicking the in vivo environments. The aim of this evaluation was to determine whether fabricated tubular tissue models developed their mechanical properties. The cellular response to hemodynamic stimulus imposed by the dynamic culture system is monitored through expression analysis of fibrillin-1 and fibrillin-2, elastin and smooth muscle myosin heavy chains isoforms transcription factors, which play an important role in tissue elastogenesis. Among the available materials for small blood vessel construction, these cellular hybrid vascular scaffolds hold much potential due to controllability of the mechanical properties of synthetic polymers and biocompatibility of integrated cellular components.
Collapse
Affiliation(s)
- Taisuke Masuda
- Department of Micro-Nano Mechanical Science and Engineering, Graduate School of Engineering, Nagoya University, 1 Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan.
| | - Mitsuhiro Ukiki
- Department of Micro-Nano Mechanical Science and Engineering, Graduate School of Engineering, Nagoya University, 1 Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan
| | - Yuka Yamagishi
- Department of Micro-Nano Mechanical Science and Engineering, Graduate School of Engineering, Nagoya University, 1 Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan
| | - Michiya Matsusaki
- Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Osaka, Japan
| | - Mitsuru Akashi
- Building Block Science, Graduate School of Frontier Bioscience, Osaka University, Osaka, Japan
| | - Utako Yokoyama
- Cardiovascular Research Institute, Yokohama City University, Yokohama, Japan
| | - Fumihito Arai
- Department of Micro-Nano Mechanical Science and Engineering, Graduate School of Engineering, Nagoya University, 1 Furo-cho, Chikusa-ku, Nagoya, 464-8603, Japan
| |
Collapse
|