1
|
Nagata M, Matsushima H, Senoo T. Effect of surface-modified intraocular lenses on long-term postoperative inhibition of posterior capsule opacification. Heliyon 2024; 10:e33006. [PMID: 39022042 PMCID: PMC11252701 DOI: 10.1016/j.heliyon.2024.e33006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 05/09/2024] [Accepted: 06/12/2024] [Indexed: 07/20/2024] Open
Abstract
We compared the posterior capsule opacification incidences at 5 years postoperatively and the neodymium-yttrium-aluminum-garnet capsulotomy rates at 10 years postoperatively for two types of intraocular lenses with different optical properties and shapes. This randomized, controlled, prospective, single-blinded study with intra-individual comparisons was conducted between July 21, 2009, and August 31, 2011, at the Dokkyo Medical University Hospital, Tochigi, Japan. Thirty patients (60 eyes) underwent bilateral cataract surgery and received a XY1 intraocular lens in one eye and a FY-60AD intraocular lens in the other. Both intraocular lenses are acrylic and manufactured by HOYA. The XY1 lens is a single-piece, tinted intraocular lens featuring an ultraviolet/ozone treatment on the posterior surface of the lens optic, aimed at enhancing posterior capsule adhesion to prevent posterior capsule opacification. Conversely, the FY-60AD is a tinted intraocular lens with modified polymethylmethacrylate C-loops and no ultraviolet/ozone treatment of the optic. Scheimpflug images were taken using EAS-1000 (NIDEK Co., Ltd., Aichi, Japan), and the scattered light intensity (computer compatible tape) on the posterior surface of the intraocular lens was calculated and evaluated as the posterior capsule opacification. The scattered light values of the XY1 and FY-60AD groups were 6.50 ± 5.69 and 11.64 ± 5.30 computer compatible tape, respectively, at 5 years postoperatively. The cumulative survival incidence after neodymium-yttrium-aluminum-garnet laser capsulotomy was 74.8 % in the XY1 group and 13.8 % in the FY-60AD group at 10 years postoperatively. The surface-modified intraocular lens XY1 reduced the incidence of posterior capsule opacification even 10 years after surgery. Surface modification to increase the adhesion between the intraocular lens and the capsule effectively prevents posterior capsule opacification.
Collapse
Affiliation(s)
- Mayumi Nagata
- Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu City, Tochigi, 321-0293, Japan
| | - Hiroyuki Matsushima
- Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu City, Tochigi, 321-0293, Japan
| | - Tadashi Senoo
- Department of Ophthalmology, Dokkyo Medical University, 880 Kitakobayashi, Mibu City, Tochigi, 321-0293, Japan
| |
Collapse
|
2
|
Mita N, Yamazaki M, Seki Y, Sasaki Y, Shibuya E, Mito T, Hatsusaka N, Kubo E, Sasaki H. Prediction of low-addition segmented refractive intraocular lens position and deviation using anterior-segment optical coherence tomography. PLoS One 2024; 19:e0305076. [PMID: 38857255 PMCID: PMC11164357 DOI: 10.1371/journal.pone.0305076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Accepted: 05/22/2024] [Indexed: 06/12/2024] Open
Abstract
This study aimed to develop and analyze the accuracy of predictive formulae for postoperative anterior chamber depth, tilt, and decentration of low-added-segment refractive intraocular lenses. This single-center, retrospective, observational study included the right eyes of 96 patients (mean age: 72.43 ± 6.58 years), who underwent a cataract surgery with implantation of a low-added segmented refractive intraocular lens at the Medical University Hospital between July 2019 and January 2021, and were followed up for more than 1 month postoperatively. The participants were divided into an estimation group to create a prediction formula and a validation group to verify the accuracy of the formula. Anterior segment optical coherence tomography (CASIA 2, Tomey Corporation, Japan) and swept-source optical coherence tomography biometry (IOL Master 700, Carl Zeiss Meditec AG) were used to measure the anterior ocular components. A predictive formula was devised for postoperative anterior chamber depth, intraocular lens tilt, and intraocular lens decentration (p <0.01) in the estimation group. A significant positive correlation was observed between the estimated values calculated using the prediction formula and the measured values for postoperative anterior chamber depth (r = 0.792), amount of intraocular lens tilt (r = 0.610), direction of intraocular lens tilt (r = 0.668), and amount of intraocular lens decentration (r = 0.431) (p < 0.01) in the validation group. In conclusion, our findings reveal that predicting the position of the low-added segmented refractive intraocular lens enables the prognosis of postoperative refractive values with a greater accuracy in determining the intraocular lens adaptation.
Collapse
Affiliation(s)
- Norihiro Mita
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Mai Yamazaki
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Yusuke Seki
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Yu Sasaki
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Eri Shibuya
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Tsuyoshi Mito
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Natsuko Hatsusaka
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Eri Kubo
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| | - Hiroshi Sasaki
- Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan
| |
Collapse
|
3
|
Belda JI, Placeres J, Elvira JC, Puig X, Pérez-Vives C, Zou M, Yu J, Sun S, O’Boyle D. Five-Year Incidence of Nd:YAG Capsulotomy After Cataract Surgery with Different Single-Piece Monofocal Intraocular Lenses: A Follow-Up Study of 3955 Eyes. Clin Ophthalmol 2024; 18:1599-1605. [PMID: 38855011 PMCID: PMC11162221 DOI: 10.2147/opth.s441012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 04/18/2024] [Indexed: 06/11/2024] Open
Abstract
Purpose To estimate the incidence of neodymium-doped yttrium aluminum garnet laser (Nd:YAG) capsulotomy up to five years after cataract surgery with different single-piece acrylic monofocal IOLs in a Spanish cohort. Patients and Methods Data were extracted from electronic medical records. Eligible participants were aged ≥65, had cataract surgery with one of five different acrylic monofocal IOLs (Alcon AcrySof, AJL LLASY60, Medicontur Bi-flex, IOL Tech Stabibag and Zeiss Asphina), and more than six months baseline data. Participants were followed up to five years from surgery and up to six months from Nd:YAG. The incidence of Nd:YAG was compared between the IOLs and multivariate analyses were conducted to identify predictors of Nd:YAG incidence at five-years after cataract surgery. Results The initial cohort included 9545 patients with 14,519 eyes (53% female, average age 75 years). Of those, 3955 eyes were available for analysis five years after cataract surgery. Throughout the five years post-surgery, Nd:YAG incidence was consistently lower with Alcon Acrysof IOLs than the other IOLs. At five years the Nd:YAG incidence rate for Alcon Acrysof was 8.8%. In comparison, the incidence was 47.4% for AJL LLASY60 (OR = 9.54, 95% CI [6.57, 13.84]), 44.3% for Zeiss Asphina (OR = 8.35, 95% CI [5.85, 11.94]) and 44.0% for IOL Tech Stabibag (OR = 8.02, 95% CI [4.60, 13.84]). Conclusion Alcon AcrySof IOLs have a consistently lower risk of Nd:YAG incidence over a long follow-up period after cataract surgery, highlighting the importance of IOL choice for patients' long-term outcomes.
Collapse
Affiliation(s)
- José I Belda
- Department of Ophthalmology, Hospital Universitario de Torrevieja, Alicante, Spain
- Visionker Eye Clinic, Alicante, Spain
| | - Javier Placeres
- Department of Ophthalmology, Hospital Universitario de Torrevieja, Alicante, Spain
- Visionker Eye Clinic, Alicante, Spain
| | - Juan C Elvira
- Department of Ophthalmology, Hospital Universitario del Vinalopó, Alicante, Spain
| | | | | | - Ming Zou
- IQVIA Real World Solutions, Basel, Switzerland
| | - Jing Yu
- IQVIA Real World Solutions, Basel, Switzerland
| | - Shaohui Sun
- IQVIA Real World Solutions, Basel, Switzerland
| | | |
Collapse
|
4
|
Schickhardt SK, Łabuz G, Munro DJ, Lieberwirth I, Zhang L, Fang H, Auffarth GU. In-vitro assessment of a novel intraocular lens made of crosslinked polyisobutylene. J Mech Behav Biomed Mater 2024; 152:106368. [PMID: 38340476 DOI: 10.1016/j.jmbbm.2023.106368] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 12/29/2023] [Accepted: 12/31/2023] [Indexed: 02/12/2024]
Abstract
PURPOSE To describe and analyse the particularities of the material and the optical quality of the first intraocular lens (IOL) (Eyedeal® lens) made of crosslinked polyisobutylene (xPIB). METHODS We assessed the material quality using an accelerated ageing process (to provoke glistenings) and compared values with a control, AcrySof® lens. Using the sessile drop method, the contact angle of the new IOL was measured. Images of the lens surface were recorded by scanning electron microscopy (SEM). Optical quality was assessed by measuring the labeled power and modulation transfer function (MTF) using standard metrology equipment (OptiSpheric IOL PRO2). RESULTS The Eyedeal® lens had an average glistening density result of 7.46 ± 3.78 MV/mm2 compared to the control AcrySof® whose glistenings number was 142.42 ± 72.47 MV/mm2. The contact angle was 97.2° whereas the angle of AcrySof material is between 73.3 ± 2.4° and 84.4 ± 0.1°. Using SEM, Eyedeal® lenses were examined and all appeared to be comparable to modern IOLs made of acrylic materials. The power and MTF values were normal and conformed to ISO standards. CONCLUSIONS In the laboratory, the new Eyedeal® lens showed equivalence to current hydrophobic- or hydrophilic-acrylic lens models. It showed superiority in its glistening density result compared to the control lens.
Collapse
Affiliation(s)
- Sonja K Schickhardt
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany.
| | - Grzegorz Łabuz
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany.
| | - Donald J Munro
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany.
| | | | - Lu Zhang
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany.
| | - Hui Fang
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany.
| | - Gerd U Auffarth
- The David J. Apple International Laboratory for Ocular Pathology, Department of Ophthalmology, University Hospital of Heidelberg, Heidelberg, Germany.
| |
Collapse
|
5
|
Lin X, Ma D, Yang J. Exploring anterion capsular contraction syndrome in cataract surgery: insights into pathogenesis, clinical course, influencing factors, and intervention approaches. Front Med (Lausanne) 2024; 11:1366576. [PMID: 38439904 PMCID: PMC10911763 DOI: 10.3389/fmed.2024.1366576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 02/05/2024] [Indexed: 03/06/2024] Open
Abstract
Anterior capsular contraction syndrome (ACCS) is a challenging complication that can occur following phacoemulsification cataract surgery. Characterized by capsular bag wrinkling, intraocular lens (IOL) decentration and tilt, ACCS can have negative effects on visual outcomes and patient satisfaction. This review aims to investigate the pathogenesis, clinical course, influencing factors, and intervention approaches for ACCS after cataract surgery. By understanding the underlying mechanisms and identifying factors that contribute to ACCS, surgeons can enhance their ability to predict and manage this complication. Various intervention strategies are discussed, highlighting their importance in reducing complications and improving surgical outcomes. However, further research is needed to determine optimal prevention and management strategies through long-term follow-up and comparative analyses. Advancements in this field will ultimately lead to improved visual outcomes and optimized cataract surgery for patients.
Collapse
Affiliation(s)
- Xuanqiao Lin
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key NHC Laboratory of Myopia, Fudan University, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Dongmei Ma
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key NHC Laboratory of Myopia, Fudan University, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Jin Yang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key NHC Laboratory of Myopia, Fudan University, Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| |
Collapse
|
6
|
Lin X, Ma D, Yang J. Insights into the rotational stability of toric intraocular lens implantation: diagnostic approaches, influencing factors and intervention strategies. Front Med (Lausanne) 2024; 11:1349496. [PMID: 38414624 PMCID: PMC10896894 DOI: 10.3389/fmed.2024.1349496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Accepted: 01/30/2024] [Indexed: 02/29/2024] Open
Abstract
Toric intraocular lenses (IOLs) have been developed to enhance visual acuity impaired by cataracts and correct corneal astigmatism. However, residual astigmatism caused by postoperative rotation of the toric IOL is an important factor affecting visual quality after implantation. To decrease the rotation of the toric IOL, significant advancements have been made in understanding the characteristics of toric IOL rotation, the factors influencing its postoperative rotation, as well as the development of various measurement techniques and interventions to address this issue. It has been established that factors such as the patient's preoperative refractive status, biological parameters, surgical techniques, postoperative care, and long-term management significantly impact the rotational stability of the toric IOL. Clinicians should adopt a personalized approach that considers these factors to minimize the risk of toric IOL rotation and ensure optimal outcomes for each patient. This article reviews the influence of various factors on toric IOL rotational stability. It discusses new challenges that may be encountered to reduce and intervene with rotation after toric IOL implantation in the foreseeable future.
Collapse
Affiliation(s)
- Xuanqiao Lin
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key NHC Laboratory of Myopia, Fudan University, and Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, China
| | - Dongmei Ma
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key NHC Laboratory of Myopia, Fudan University, and Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| | - Jin Yang
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China
- Key NHC Laboratory of Myopia, Fudan University, and Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Key Laboratory of Visual Impairment and Restoration, Shanghai, China
| |
Collapse
|
7
|
Randomized multicenter trial to assess posterior capsule opacification and glistenings in two hydrophobic acrylic intraocular lenses. Sci Rep 2023; 13:2822. [PMID: 36805494 PMCID: PMC9938215 DOI: 10.1038/s41598-023-29855-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 02/11/2023] [Indexed: 02/19/2023] Open
Abstract
To evaluate the long-term posterior capsule opacification (PCO) formation, and glistening rate of the HOYA Vivinex (XY1) IOL compared to Alcon AcrySof (SN60WF). In this prospective, multicentric, randomized, paired-eye, open-label study, we included 87 subjects that underwent cataract surgery with IOL implantation, with 67 patients completing the 3-year follow-up. The completer population consisted of 32 subjects implanted with XY1 and 35 implanted with SN60WF. Primary endpoints consisted of the evaluation of glistenings and measurement of PCO. Secondary outcomes included Best Corrected Distance Visual Acuity (BCVA), Contrast Acuity (CA), uncorrected visual acuities, subjective refraction, medical and lens complication rates, adverse events, and optical/visual symptoms. Follow-up visits occurred at 6-months, 1-, 2- and 3-years. At 3-years follow-up, mean PCO score was 0.121 ± 0.193 for eyes implanted with Vivinex versus 0.239 ± 0.463 for AcrySof (p = 0.026). The Vivinex IOL showed statistically significantly lower glistening occurrence through 3-years postoperatively (0.14 ± 0.26) compared to AcrySof (1.79 ± 1.43; p < 0.0001). Postoperative visual acuities improved from baseline in both IOL groups (p < 0.0001), and remained stable through the 3-year follow-up period. Eyes implanted with a HOYA Vivinex IOL exhibited significantly lower occurrence of glistening at 3-years versus Alcon AcrySof (p < 0.0001). Incidence of PCO was very low and comparable in both Vivinex and AcrySof eyes.
Collapse
|
8
|
Belda JI, Dabán JP, Elvira JC, O’Boyle D, Puig X, Pérez-Vives C, Zou M, Sun S. Nd:YAG capsulotomy incidence associated with five different single-piece monofocal intraocular lenses: a 3-year Spanish real-world evidence study of 8293 eyes. Eye (Lond) 2022; 36:2205-2210. [PMID: 34764439 PMCID: PMC9581982 DOI: 10.1038/s41433-021-01828-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 09/23/2021] [Accepted: 10/18/2021] [Indexed: 12/30/2022] Open
Abstract
OBJECTIVES To investigate the associations between different single-piece monofocal intraocular lenses (IOLs) and neodymium-doped yttrium aluminum garnet laser (Nd:YAG) capsulotomy incidence 3 years after cataract surgery in a Spanish cohort. METHODS This is a longitudinal retrospective cohort study. Data were extracted from the electronic medical records of two large regional hospitals in Spain. Patients aged ≥65 years receiving cataract surgery with placement of five different IOLs and with ≥6 months of baseline data were included. We report the Nd:YAG capsulotomy incidence 3 years post cataract surgery, and the survival plot over the 3 years of follow-up time. The associated adjusted (age, gender, and diabetic retinopathy) multivariate analysis with odds ratios (ORs) and 95% CIs is also presented. RESULTS The cohort (53% female, mean age 75 ± 5.9 years) included 14,519 eyes (Alcon AcrySof = 2968, AJL LLASY60 = 1776, Medicontur Bi-flex = 5176, Zeiss Asphina = 4478, and IOL Tech Stabibag = 121). Of these, 8293 were retained until 3-year follow-up. At 3 years after cataract surgery, the Nd:YAG capsulotomy incidence was 5% for Alcon AcrySof, while it ranged from 21.2% to 31.1% for the other IOLs (p < 0.0001 for each comparison). The odds for Nd:YAG capsulotomy were significantly higher (p < 0.0001) for other IOLs compared with those of Alcon AcrySof (ORs = 8.85, 5.86, 5.74, 5.21 for AJL LLASY60, Medicontur Bi-flex, IOL Tech Stabibag, and Zeiss Asphina, respectively). CONCLUSIONS The lower Nd:YAG capsulotomy rates for Alcon AcrySof IOLs compared to the other IOLs support the importance of lens choice in reducing patient burden and treatment costs.
Collapse
Affiliation(s)
- José I. Belda
- Hospital Universitario de Torrevieja, Torrevieja, Alicante Spain
| | | | | | | | | | | | - Ming Zou
- IQVIA Real World Solutions, Basel, Switzerland
| | - Shaohui Sun
- IQVIA Real World Solutions, Basel, Switzerland
| |
Collapse
|
9
|
Role of fibronectin and IOL surface modification in IOL: Lens capsule interactions. Exp Eye Res 2022; 221:109135. [PMID: 35662618 DOI: 10.1016/j.exer.2022.109135] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Revised: 05/25/2022] [Accepted: 05/27/2022] [Indexed: 11/20/2022]
Abstract
Posterior Capsule Opacification (PCO) is one of the most common complications of cataract surgery. While studies have shown that IOL material properties and fibronectin adsorption may affect IOL-induced PCO in the clinical setting, the mechanism governing such interactions is not totally understood. Since strong adhesion forces between IOLs and posterior capsules (PCs) have been shown to impede cell infiltration and thus reduce PCO formation, this study was designed to assess whether fibronectin adsorption and IOL material properties would impact the IOL:PC adhesion force and cell infiltration using a PCO predictive in vitro model and a macromolecular dye imaging model, respectively. Our results showed that fibronectin adsorption significantly increased the adhesion forces and reduced simulated cell infiltration between acrylic foldable IOLs and the PC at physiological temperature in comparison to fibronectin-free controls. This fibronectin-mediated strong IOL: PC bond may be contributing to low PCO rates in the clinic for acrylic foldable IOLs. In addition, acrylic foldable IOLs coated with Di(ethylene glycol) (Diglyme), a hydrophilic coating known to reduce protein adsorption, was tested for its ability to alter adhesion force and cell infiltration. We observed that IOLs coated with Diglyme coating greatly reduced surface hydrophobicity and fibronectin adsorption of acrylic foldable IOLs. Furthermore, Diglyme coated IOLs showed significantly reduced adhesion force and increased simulated cell infiltration at the IOL:PC interface. The overall results support the hypothesis that IOL surface properties and their ability to adsorb fibronectin may have great impact on the IOL:PC adhesion force. A tight binding between IOLs and PC may contribute to the reduction of cell infiltration and thus the PCO incidence rate in the clinic.
Collapse
|
10
|
Horn JD, Fisher BL, Terveen D, Fevrier H, Merchea M, Gu X. Academy IRIS® Registry Analysis of Incidence of Laser Capsulotomy Due to Posterior Capsule Opacification After Intraocular Lens Implantation. Clin Ophthalmol 2022; 16:1721-1730. [PMID: 35673348 PMCID: PMC9167596 DOI: 10.2147/opth.s358059] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2022] [Accepted: 05/10/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
- Jeffrey D Horn
- Vision for Life, Nashville, TN, USA
- Correspondence: Jeffrey D Horn, Vision for Life, Nashville, TN, USA, Tel +1 615-588-2020, Email
| | | | | | | | | | | |
Collapse
|
11
|
Grzybowski A, Zemaitiene R, Markeviciute A, Tuuminen R. Should We Abandon Hydrophilic Intraocular Lenses? Am J Ophthalmol 2022; 237:139-145. [PMID: 34843687 DOI: 10.1016/j.ajo.2021.11.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 11/02/2021] [Accepted: 11/16/2021] [Indexed: 11/18/2022]
Abstract
PURPOSE To characterize the features of hydrophilic intraocular lenses (IOLs) important in the clinical context of expected prolonged duration time of the IOL within the eye. DESIGN Perspective. METHODS Discussion includes possible factors and mechanisms associated with hydrophilic IOLs' susceptibility to calcification and posterior capsule opacification (PCO) formation. RESULTS Results of recently reported studies show that particular surgeries, such as pars plana vitrectomy, Descemet stripping (automated) endothelial keratoplasty, and Descemet membrane endothelial keratoplasty with intraocular gas or air injection, might predispose the calcification process of hydrophilic IOLs, leading to a significant decrease in visual quality and possibly explantation of the IOL. Hydrophilic IOLs are more susceptible than hydrophobic IOLs to PCO formation, which is the most common of late postoperative complications that are associated with significant side effects. CONCLUSIONS We believe that all patients should be informed about the higher risk of calcification and PCO associated with hydrophilic IOLs. We also recommend limiting the use of hydrophilic acrylic IOLs during cataract surgery, especially when it is combined with pars plana vitrectomy or endothelial keratoplasty, and in patients with endothelial diseases who will probably require operation on it in the future.
Collapse
Affiliation(s)
- Andrzej Grzybowski
- From the Department of Ophthalmology, University of Warmia and Mazury, (A.G.), Olsztyn; Institute for Research in Ophthalmology (A.G.), Poznan, Poland.
| | - Reda Zemaitiene
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences (R.Z., A.M.), Kaunas, Lithuania
| | - Agne Markeviciute
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences (R.Z., A.M.), Kaunas, Lithuania
| | - Raimo Tuuminen
- Helsinki Retina Research Group, University of Helsinki (R.T.), Helsinki; Department of Ophthalmology, Kymenlaakso Central Hospital (R.T.), Kotka, Finland
| |
Collapse
|
12
|
Osorno LL, Mosley RJ, Poley PL, Bowers J, Gorski G, Gerhart J, Getts R, George-Weinstein M, Byrne ME. Sustained Release of Antibody-Conjugated DNA Nanocarriers from a Novel Injectable Hydrogel for Targeted Cell Depletion to Treat Cataract Posterior Capsule Opacification. J Ocul Pharmacol Ther 2022; 38:404-411. [PMID: 35377237 DOI: 10.1089/jop.2021.0111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Purpose: To compare a novel, sustained release formulation and a bolus injection of a targeted nanocarrier for the ability to specifically deplete cells responsible for the development of posterior capsule opacification (PCO) in week-long, dynamic cell cultures. Methods: A novel, injectable, thermosensitive poly(D,L-lactic-co-glycolic acid)-b-poly(ethylene glycol)-b-poly(D,L-lactic-co-glycolic acid) (PLGA-PEG-PLGA) triblock copolymer hydrogel was engineered for the sustained release of targeted, nucleic acid nanocarriers loaded with cytotoxic doxorubicin (G8:3DNA:Dox). Human rhabdomyosarcoma (RD) cells were used due to their expression of brain-specific angiogenesis inhibitor 1 (BAI1), a specific marker for the myofibroblasts responsible for PCO. Under constant media flow, nanocarriers were injected into cell cultures as either a bolus or within the hydrogel. Cells were fixed and stained every other day for 7 days to compare targeted depletion of BAI1+ cells. Results: The formulation transitions to a gel at physiological temperatures, is optically clear, noncytotoxic, and can release G8:3DNA:Dox nanocarriers for up to 4 weeks. In RD cell cultures, G8:3DNA:Dox nanocarriers specifically eliminated BAI1+ cells. The bolus nanocarrier dose showed significantly reduced cell depletion overtime, while the sustained release of nanocarriers showed increased cell depletion over time. By day 7, <2% of BAI1+ cells were depleted by the bolus injection and 74.2% BAI1+ cells were targeted by the sustained release of nanocarriers. Conclusions: The sustained release of nanocarriers from the hydrogel allows for improved therapeutic delivery in a dynamic system. This method can offer a more effective and efficient method of prophylactically treating PCO after cataract surgery.
Collapse
Affiliation(s)
- Laura L Osorno
- Biomimetic and Biohybrid Materials, Biomedical Devices, and Drug Delivery Laboratories, Department of Biomedical Engineering, Rowan University, Glassboro, New Jersey, USA
| | - Robert J Mosley
- Biomimetic and Biohybrid Materials, Biomedical Devices, and Drug Delivery Laboratories, Department of Biomedical Engineering, Rowan University, Glassboro, New Jersey, USA
| | - Patricia L Poley
- Biomimetic and Biohybrid Materials, Biomedical Devices, and Drug Delivery Laboratories, Department of Biomedical Engineering, Rowan University, Glassboro, New Jersey, USA
| | | | - Grzegorz Gorski
- Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania, USA
| | - Jacquelyn Gerhart
- Philadelphia College of Osteopathic Medicine, Philadelphia, Pennsylvania, USA
| | | | | | - Mark E Byrne
- Biomimetic and Biohybrid Materials, Biomedical Devices, and Drug Delivery Laboratories, Department of Biomedical Engineering, Rowan University, Glassboro, New Jersey, USA.,Department of Chemical Engineering, Rowan University, Glassboro, New Jersey, USA.,OcuMedic, Inc., Mullica Hill, New Jersey, USA
| |
Collapse
|
13
|
Belda JI, Placeres J, Elvira JC, Puig X, Pérez-Vives C, Zou M, Sun S, Yu J, O’Boyle D. Costs and Healthcare Resource Utilization Associated with Posterior Capsule Opacification After Cataract Surgery with Five Different Intraocular Lenses: An Economic Analysis for Spain. Clin Ophthalmol 2022; 16:993-1001. [PMID: 35386615 PMCID: PMC8979752 DOI: 10.2147/opth.s349003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 01/21/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose Materials and Methods Results Conclusion
Collapse
Affiliation(s)
- José I Belda
- Hospital Universitario de Torrevieja, Torrevieja, Alicante, Spain
| | - Javier Placeres
- Hospital Universitario de Torrevieja, Torrevieja, Alicante, Spain
| | | | | | | | - Ming Zou
- IQVIA Real World Solutions, Basel, Switzerland
| | - Shaohui Sun
- IQVIA Real World Solutions, Basel, Switzerland
| | - Jing Yu
- IQVIA Real World Solutions, Basel, Switzerland
| | - Derek O’Boyle
- Alcon Laboratories Ireland Ltd., Cork, Ireland
- Correspondence: Derek O’Boyle, Alcon Laboratories Ireland Ltd., Cork, Ireland, Email
| |
Collapse
|
14
|
Posterior Capsule Opacification after Cataract Surgery via Implantation with Hydrophobic Acrylic Lens Compared with Silicone Intraocular Lens: A Systematic Review and Meta-Analysis. J Ophthalmol 2022; 2022:3570399. [PMID: 35251708 PMCID: PMC8896947 DOI: 10.1155/2022/3570399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 01/26/2022] [Indexed: 11/18/2022] Open
Abstract
Hydrophobic acrylic intraocular lens (IOL) is the most popular material in cataract surgery. Posterior capsule opacification (PCO) is a long-term complication of cataract surgery. It can impair vision and adversely affect the prognosis of IOL delamination. The objective of this study was to perform a systematic review and meta-analysis to provide an updated evaluation of long-term complications and visual function after implantation with hydrophobic acrylic and silicone intraocular lenses. PubMed, Embase, and Cochrane Library were searched from January 2000 until March 2021. Randomized controlled trials (RCTs) and retrospective studies were finally included. The main outcomes were PCO value and neodymium-doped yttrium aluminum garnet (Nd : YAG) capsulotomy rate. Subgroup analysis was performed to compare hydrophobic acrylic and silicone IOLs during the follow-up period. Sensitivity analysis was also performed. The meta-analysis included a total of 17 studies. When the follow-up period was considered, the results of the analysis revealed higher PCO value (Group 3: standardized mean difference (SMD), −0.59; 95% confidence interval (CI), −0.90 to −0.28) and Nd : YAG capsulotomy rate (Group 3: risk ratio (RR), 0.60; 95% CI, 0.40–0.89) for hydrophobic acrylic IOLs than silicone IOLs during a long-term (≥6 years) follow-up. In conclusion, both the PCO value and the Nd : YAG capsulotomy rates were higher in hydrophobic acrylic IOLs group than the silicone IOLs group at long-term use (more than 6 years) after implantation.
Collapse
|
15
|
Mao Y, Liu H, Long Gu F, Wu MX, Wang Y. The molecular design of performance-enhanced intraocular lens composites. Biomater Sci 2022; 10:1515-1522. [PMID: 35171153 DOI: 10.1039/d1bm01919h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Intraocular lens (IOL) implantation surgery is quite effective in the treatment of blindness caused by cataracts. However, in clinical applications, IOLs readily form glistening. This phenomenon usually occurs for a period after IOL implantation ranging from a few months to several years. The molecular mechanism of the formation of glistening in IOLs is still inconclusive. Failure to understand and explain the molecular mechanism of glistening formation greatly hinders the design and application of new glistening-free IOL materials. Here, in this study, we use molecular dynamics simulation methods to conduct in-depth research on the molecular mechanism of the glistening formation of IOLs, aiming to provide a possible molecular mechanism of glistening. Furthermore, based on this molecular mechanism, we propose a novel strategy of a glistening-free material based on a composite design method to reasonably copolymerize several types of molecules or functional groups, so that the glistening phenomenon can be effectively eliminated. The possible molecular mechanism of glistening formation proposed in this research can offer a solid theoretical basis and guidance for the subsequent construction of glistening-free IOL materials.
Collapse
Affiliation(s)
- Yan Mao
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, 510000, People's Republic of China.
| | - Hong Liu
- Key Laboratory of Theoretical Chemistry of Environment Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, Guangdong 510006, People's Republic of China.
| | - Feng Long Gu
- Key Laboratory of Theoretical Chemistry of Environment Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, Guangdong 510006, People's Republic of China.
| | - Ming-Xing Wu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, 510000, People's Republic of China.
| | - Yan Wang
- Key Laboratory of Theoretical Chemistry of Environment Ministry of Education, School of Chemistry, South China Normal University, Guangzhou, Guangdong 510006, People's Republic of China.
| |
Collapse
|
16
|
The Influence of Inflammation in Posterior Capsule Opacification Development. SERBIAN JOURNAL OF EXPERIMENTAL AND CLINICAL RESEARCH 2022. [DOI: 10.2478/sjecr-2021-0075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Abstract
Cataract represents the reduction of the transparency of the crystalline lens. Cataract surgery is the most commonly performed surgical procedure worldwide. One of the most common postoperative complication of successfully performed cataract surgery is a development of posterior capsule opacification (PCO). In the postoperative period, lens epithelial cells (LECs) undergo proliferation, migration and differentiation, which is clinically manifested by the development of PCO. Inflammation has a central role in these processes. Cytokines, such as transforming growth factor β, fibroblast growth factor, interleukin 1, interleukin 6, matrix metalloproteinases have a huge effect on the activity of LECs. Understanding these processes can find a great usage in clinical practice. By prescribing anti-inflammatory therapy in the early postoperative period, the incidence of PCO can be significantly reduced.
Collapse
|
17
|
Wang Y, Wang W, Zhu Y, Xu J, Luo C, Yao K. Comparison Study of Anterior Capsule Contraction of Hydrophilic and Hydrophobic Intraocular Lenses Under the Same Size Capsulotomy. Transl Vis Sci Technol 2022; 11:24. [PMID: 35040916 PMCID: PMC8764210 DOI: 10.1167/tvst.11.1.24] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To compare anterior capsule contraction of two kinds of hydrophilic and hydrophobic acrylic intraocular lenses (IOLs) under the same size capsulotomy with femtosecond laser-assisted cataract surgery (FLACS). Methods A total of 320 eyes in 320 patients who underwent FLACS were included. The patients were scheduled to have hydrophilic acrylic IOLs (MI60, 509M) and hydrophobic acrylic IOLs (iSert250, ZCB00) implanted. Visual acuity and anterior segment photography using a slit lamp microscope were performed at postoperative one week, one month, three months, and one year. Results The contraction of the anterior capsule opening area (mm2) and circumference (mm) in the hydrophilic group were larger than that of the hydrophobic group from postoperative one week to one year (P < 0.001, P < 0.001, respectively). The postoperative contraction of the capsule opening area in MI60 was larger than in 509M (P < 0.001) and larger in 509M than in iSert250 and ZCB00 (P = 0.008, P = 0.019, respectively), but no difference was observed between iSert250 and ZCB00 (P = 0.867). During postoperative one to three months, all groups had the maximum capsule contraction (P < 0.001). Conclusions Under the same size capsulotomy with FLACS, the postoperative anterior capsule contraction induced by hydrophobic IOLs was less than that induced by hydrophilic IOLs. Among the four IOLs, the capsule contraction was largest in MI60, followed by 509M, and least in iSert250 and ZCB00, which was time-dependent. Translational Relevance Our findings implied that patients with a high risk of ACC should choose hydrophobic IOLs, as well as nonsteroidal anti-inflammatory drugs may be used for a longer period in patients with high risk of capsule contraction syndrome.
Collapse
Affiliation(s)
- Yuyan Wang
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Wei Wang
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Yanan Zhu
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Jia Xu
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Chenqi Luo
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| | - Ke Yao
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang Province, China
| |
Collapse
|
18
|
Fu Y, Wang D, Ding X, Chang P, Zhao Y, Hu M, Li Z, Zhao YE. Posterior Capsular Outcomes of Pediatric Cataract Surgery With In-The-Bag Intraocular Lens Implantation. Front Pediatr 2022; 10:827084. [PMID: 35463896 PMCID: PMC9024078 DOI: 10.3389/fped.2022.827084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2021] [Accepted: 03/14/2022] [Indexed: 11/17/2022] Open
Abstract
AIM To investigate the change of posterior capsular outcomes of pediatric cataract surgery with primary in-the-bag intraocular lens (IOL) implantation. METHODS We conducted a case series of pediatric cataract children who underwent cataract extraction with primary in-the-bag IOL implantation, posterior capsulorhexis or vitrectorhexis, and limited anterior vitrectomy at the Eye Hospital of Wenzhou Medical University between 2016 and 2019. Digital retro-illumination photographs of pediatric eyes were obtained at baseline and 6 months, 12 months, and the last visit postoperatively. Capsular outcomes of the posterior capsular opening area (PCOA) and lens reprolifration area at those time points were compared. Correlations between the PCOA and influential factors, such as age at surgery, axial growth, and follow-up duration, were analyzed. The study was registered at register.clinicaltrials.gov (NCT04803097). RESULTS Data of 23 patients (27 eyes) were used in the final analysis. During follow-up, the PCOA enlarged at a rate of 0.29-0.32 mm2/month during the first six months postoperatively and 0.05-0.08 mm2/month over the next 1-2 years. Six months postoperatively, the PCOA enlargement statistically and positively correlated with the follow-up duration and axial growth. The area of lens reprolifration was 0.46 ± 1.00 mm2 at six months postoperatively and then remained stable. CONCLUSION The PCOA enlarged rapidly within the first six months after the pediatric cataract surgery with primary IOL implantation. Six months postoperatively, the enlargement of PCOA was positively correlated with follow-up duration and axial growth. Posterior capsulorhexis or capsulectomy should be performed with a diameter of 3.0 to 4.0 mm for good visual axis transparency and the protection of in-the-bag IOL.
Collapse
Affiliation(s)
- Yana Fu
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| | - Dandan Wang
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| | - Xixia Ding
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| | - Pingjun Chang
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| | - Yinying Zhao
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| | - Man Hu
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| | - Zhangliang Li
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| | - Yun-E Zhao
- School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.,Key Laboratory of Vision Science, Ministry of Health, Wenzhou, China.,National Center for Clinical and Medical Research, Wenzhou, China
| |
Collapse
|
19
|
Comparative analysis of postoperative results of cataract surgery using monofocal IOLs. ACTA BIOMEDICA SCIENTIFICA 2021. [DOI: 10.29413/abs.2021-6.6-1.24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
One of the most common surgical interventions in ophthalmology today is lens replacement surgery. But there is still no consensus on whether the choice of a monofocal IOL affects the postoperative functional outcome.The aim: to conduct a comparative analysis of values of visual acuity without correction in the early postoperative period after cataract surgery using monofocal IOLs.Material and methods. The study included data of 2643 eyes operated for cataract, into which one of the monofocal IOLs, included in the top ten most frequently implanted IOLs in the Orenburg Branch of the S. Fyodorov Eye Microsurgery Federal State Institution, was implanted for the period 2019–2021. Statistical analysis was performed using the program Statistica 13.0.Results. The performed analysis of variance showed that the established differences between the compared groups are statistically signifi cant (p < 0.05). However, the subgroup analysis showed that there were statistically signifi cant differences between pairs such as Tecnis and Hydro-4; Tecnis and Rayner. In all other cases, statistically signifi cant uncorrected visual activity (UCVA) values after surgery were not established. It has also been reliably established that the presence of subluxation of the lens affects the value of UCVA after surgery.Conclusion. The results of the performed analysis in general indicate that the value of UCVA in patients in the early postoperative period after the performed surgical intervention does not depend on the manufacturer of the used IOL.
Collapse
|
20
|
Huynh TPN, Bowater RP, Bernuzzi F, Saha S, Wormstone IM. GSH Levels Serve As a Biological Redox Switch Regulating Sulforaphane-Induced Cell Fate in Human Lens Cells. Invest Ophthalmol Vis Sci 2021; 62:2. [PMID: 34854886 PMCID: PMC8648057 DOI: 10.1167/iovs.62.15.2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
Abstract
Purpose Sulforaphane (SFN) is a therapeutic phytochemical agent for many health conditions. SFN-induced cytotoxicity is shown to have promise in preventing posterior capsule opacification (PCO). In the current study, we aimed to elucidate key processes and mechanisms linking SFN treatment to lens cell death. Methods The human lens epithelial cell line FHL124 and central anterior epithelium were used as experimental models. Cell death was assessed by microscopic observation and cell damage/viability assays. Gene or protein levels were assessed by TaqMan RT-PCR or immunoblotting. Mitochondrial networks and DNA damage were assessed by immunofluorescence. Mitochondrial membrane potential, activating transcription factor 6 (ATF6) activity, ratio of reduced glutathione (GSH) to oxidized glutathione (GSSG), and glutathione reductase (GR) activity were measured using different light reporter assays. SFN metabolites were analyzed by LC-MS/MS. Results Treatment with N-acetylcysteine (NAC), a reactive oxygen species scavenger, prevented SFN-induced cell death in both models. NAC also significantly protected FHL124 cells from SFN-induced mitochondrial dysfunctions, endoplasmic reticulum stress (ERS), DNA damage and autophagy. SFN significantly depleted GSH, the major antioxidant in the eye, and reduced GR activity, despite doubling its protein levels. The most abundant SFN conjugate detected in lens cells following SFN application was SFN–GSH. The addition of GSH protected lens cells from all SFN-induced cellular events. Conclusions SFN depletes GSH levels in lens cells through conjugation and inhibition of GR activity. This leads to increased reactive oxygen species and oxidative stress that trigger mitochondrial dysfunction, ERS, autophagy, and DNA damage, leading to cell death. In summary, the work presented provides a mechanistic understanding to support the therapeutic application of SFN for PCO and other disorders.
Collapse
Affiliation(s)
| | - Richard P Bowater
- School of Biological Sciences, University of East Anglia, Norwich, United Kingdom
| | - Federico Bernuzzi
- School of Biological Sciences, University of East Anglia, Norwich, United Kingdom.,Quadram Institute, Norwich Research Park, Norwich, United Kingdom
| | - Shikha Saha
- Quadram Institute, Norwich Research Park, Norwich, United Kingdom
| | - I Michael Wormstone
- School of Biological Sciences, University of East Anglia, Norwich, United Kingdom
| |
Collapse
|
21
|
Cabeza-Gil I, Calvo B, Rico A, Reinhards-Hervás C, Rodríguez J. Mechanical characterisation of hydrophobic and hydrophilic acrylates used in intraocular lenses through depth sensing indentation. J Mech Behav Biomed Mater 2021; 126:104997. [PMID: 34848137 DOI: 10.1016/j.jmbbm.2021.104997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/08/2021] [Accepted: 11/23/2021] [Indexed: 10/19/2022]
Abstract
In this work, the mechanical behaviour of hydrophilic and hydrophobic acrylates has been characterised by depth sensing indentation. Time-dependent behaviour has been studied using load-relaxation tests. Experiments have been simulated with a finite element software using a visco-hyperelastic material model. The parameters of this model have been determined using deep learning techniques. The developed material models have been used to mechanically simulate a standard compression test of a prototype intraocular lens.
Collapse
Affiliation(s)
- I Cabeza-Gil
- Aragon Institute of Engineering Research (i3A), University of Zaragoza, Spain
| | - B Calvo
- Aragon Institute of Engineering Research (i3A), University of Zaragoza, Spain; Centro de Investigacion Biomedica en Red en Bioingenieria, Biomateriales y Nanomedicina (CIBER-BBN), Spain
| | - A Rico
- Durability and Mechanical Integrity of Structural Materials, Rey Juan Carlos University, Spain
| | - C Reinhards-Hervás
- Durability and Mechanical Integrity of Structural Materials, Rey Juan Carlos University, Spain
| | - J Rodríguez
- Durability and Mechanical Integrity of Structural Materials, Rey Juan Carlos University, Spain.
| |
Collapse
|
22
|
Yu SS, Lu CZ, Guo YW, Zhao Y, Yuan XY. Anterior segment OCT application in quantifying posterior capsule opacification severity with varied intraocular lens designs. Int J Ophthalmol 2021; 14:1384-1391. [PMID: 34540614 DOI: 10.18240/ijo.2021.09.13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 02/20/2021] [Indexed: 11/23/2022] Open
Abstract
AIM To evaluate the application of anterior segment-optical coherence tomography (AS-OCT) in posterior capsule opacification (PCO) severity assessment and analyse the relationship between PCO severity and intraocular lens (IOL) characters. METHODS PCO patients were prospectively recruited. Cross-sectional images of the anterior segment at horizontal and vertical meridians were acquired with AS-OCT. The area of the IOL-PC (posterior capsular) space and PCO severity (area, thickness, and density at 3 mm and 5 mm IOL optic regions) were measured. The relationship between PCO severity and visual acuity, comparisons of PCO severity and IOL-PC space using varied IOL designs were analysed. RESULTS One hundred PCO eyes were enrolled. IOL-PC space, PCO thickness and area were positively correlated with axial length. In addition, PCO area and thickness were positively correlated with visual acuity when it was ≤0.52 logMAR. The cut-off level of visual acuity should be 0.52 logMAR. With varied IOL designs, 3-piece C haptic IOL showed a smaller PCO area and thickness than the 1-piece 3 haptic IOL and 1-piece 4 haptic IOL. PCO area and thickness values for an IOL with a diameter ≤11.0 mm was greater than for an IOL with a diameter of 12.5 mm, and the differences were statistically significant. PCO area and thickness increased when IOL haptic angulation increased (from 0 to 12 degrees). CONCLUSION In PCO eyes, cut-off level of visual acuity is 0.52 logMAR. With more severe PCO, visual acuity maybe not enough to describe the visual function impairment. PCO severity and IOL-PC space are significantly correlated with axial length and IOL design and material.
Collapse
Affiliation(s)
- Sha-Sha Yu
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, Tianjin 300020, China
| | - Cheng-Zhe Lu
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, Tianjin 300020, China
| | - Ya-Wen Guo
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, Tianjin 300020, China
| | - Yun Zhao
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, Tianjin 300020, China
| | - Xiao-Yong Yuan
- Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Clinical College of Ophthalmology, Tianjin Medical University, Nankai University Eye Hospital, Tianjin 300020, China
| |
Collapse
|
23
|
Song Y, Overmass M, Fan J, Hodge C, Sutton G, Lovicu FJ, You J. Application of Collagen I and IV in Bioengineering Transparent Ocular Tissues. Front Surg 2021; 8:639500. [PMID: 34513910 PMCID: PMC8427501 DOI: 10.3389/fsurg.2021.639500] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 07/26/2021] [Indexed: 12/13/2022] Open
Abstract
Collagens represent a major group of structural proteins expressed in different tissues and display distinct and variable properties. Whilst collagens are non-transparent in the skin, they confer transparency in the cornea and crystalline lens of the eye. There are 28 types of collagen that all share a common triple helix structure yet differ in the composition of their α-chains leading to their different properties. The different organization of collagen fibers also contributes to the variable tissue morphology. The important ability of collagen to form different tissues has led to the exploration and application of collagen as a biomaterial. Collagen type I (Col-I) and collagen type IV (Col-IV) are the two primary collagens found in corneal and lens tissues. Both collagens provide structure and transparency, essential for a clear vision. This review explores the application of these two collagen types as novel biomaterials in bioengineering unique tissue that could be used to treat a variety of ocular diseases leading to blindness.
Collapse
Affiliation(s)
- Yihui Song
- Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
| | - Morgan Overmass
- Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
| | - Jiawen Fan
- Key Laboratory of Myopia of State Health Ministry, Department of Ophthalmology and Vision Sciences, Eye and Ear, Nose, and Throat (ENT) Hospital, Shanghai Medical College, Fudan University, Shanghai, China
| | - Chris Hodge
- Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
- New South Wales (NSW) Tissue Bank, Sydney, NSW, Australia
- Vision Eye Institute, Chatswood, NSW, Australia
| | - Gerard Sutton
- Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
- New South Wales (NSW) Tissue Bank, Sydney, NSW, Australia
- Vision Eye Institute, Chatswood, NSW, Australia
| | - Frank J. Lovicu
- Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
- Discipline of Anatomy and Histology, School of Medical Sciences, The University of Sydney, Sydney, NSW, Australia
| | - Jingjing You
- Save Sight Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
24
|
Jaitli A, Roy J, Chatila A, Liao J, Tang L. Effect of time and temperature-dependent changes of IOL material properties on IOL: Lens capsule interactions. Exp Eye Res 2021; 211:108726. [PMID: 34403680 DOI: 10.1016/j.exer.2021.108726] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2021] [Revised: 08/05/2021] [Accepted: 08/09/2021] [Indexed: 11/15/2022]
Abstract
Posterior Capsule Opacification (PCO) is the most common complication associated with Intraocular Lens (IOL) implantation. Based on the assumption that the interactions between an IOL and the lens capsule (LC) may influence the extent of PCO formation, a new in vitro model was developed to quantify the adhesion force of an IOL to simulated LC using a custom-designed micro-force tester. Using this system, we examined the influence of temperature (room temperature vs. body temperature) and incubation time (0 vs. 24 h) on the adhesion force between IOLs and LCs. The results show that, in line with clinical observations of PCO incidence, the adhesion force increased at body temperature and with increase in incubation time in the following order, Acrylic foldable IOLs > Silicone IOLs > PMMA IOLs. By examining the changes of surface properties as a function of temperature and incubation time, we found that acrylic foldable IOLs showed the largest increase in their hydrophilicity and reported the lowest surface roughness in comparison to other IOL groups. Coincidentally, using a newly established macromolecular dye imaging system to simulate cell migration between IOLs and LC, we observed that the amount of macromolecular dye infiltration between IOLs and LCs was in the following order: PMMA IOLs > Silicone IOLs > Acrylic foldable IOLs. These results support a new potential mechanism that body temperature, incubation time, surface hydrophilicity and smoothness of IOLs greatly contribute to their tight binding to LCs and such tight binding may lead to reduced IOL: LC space, cell infiltration, and thus PCO formation.
Collapse
Affiliation(s)
- Arjun Jaitli
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Joyita Roy
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Amjad Chatila
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Jun Liao
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA
| | - Liping Tang
- Department of Bioengineering, University of Texas at Arlington, Arlington, TX, 76019, USA; Department of Biomedical Science and Environmental Biology, Kaohsiung Medical University, Kaohsiung, 807, Taiwan.
| |
Collapse
|
25
|
Changing practice patterns in European cataract surgery as reflected in the European Registry of Quality Outcomes for Cataract and Refractive Surgery 2008 to 2017. J Cataract Refract Surg 2021; 47:373-378. [PMID: 33086294 DOI: 10.1097/j.jcrs.0000000000000457] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 09/17/2020] [Indexed: 11/26/2022]
Abstract
PURPOSE To study practice patterns in European cataract surgery over a 10-year period. SETTING European clinics affiliated to the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO). DESIGN Registry cohort study. METHODS The EUREQUO contains preoperative, intraoperative, and postoperative parameters reported by surgeons in many European clinics. All data reported to the registry are anonymized. Preoperative parameters included age, sex, visual acuity, target refraction, ocular comorbidity, and surgical difficulties. Surgical data included anesthesia, surgical technique, intraocular lens optic biomaterial, and complications. Postoperative parameters included visual acuity, refraction, and short-term complications. RESULTS During the study period (January 1, 2008, to December 31, 2017), a total of 2 714 108 cataract extractions were reported to the EUREQUO. Preoperative data changed over time, with decreases in mean age (74.5-73.0 years), proportion of women from 60.6% (100 373/165 628) to 57.2% (174 908/305 845), and proportion of coexisting eye diseases from 30.0% (49 638/165 650) to 27.0% (82 704/305 846) and with improvements in preoperative visual acuity (mean logarithm of minimum angle of resolution [logMAR] 0.46 to 0.37). The use of topical anesthesia increased over time from 28.1% (26 238/93 320) to 71.7% (130 525/182 083). Surgical complications showed a significant decrease from 2.5% (4107/165 650) to 1.2% (3573/305 846). The visual outcome improved over time (mean logMAR 0.08 to 0.05), as did the absolute median prediction error (0.38 diopter [D] to 0.28 D). CONCLUSIONS Trends in European cataract surgery practice patterns from 2008 to 2017 have moved toward younger patients with better preoperative visual acuity, fewer surgical complications, and better predicted refractions and visual outcomes.
Collapse
|
26
|
Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics. J Clin Med 2021; 10:jcm10153268. [PMID: 34362052 PMCID: PMC8347739 DOI: 10.3390/jcm10153268] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 07/16/2021] [Accepted: 07/22/2021] [Indexed: 02/06/2023] Open
Abstract
This semi-prospective, parallel, comparative investigation evaluated the clinical outcomes and quality of vision (contrast sensitivity, visual function, dysphotopsia, spectacle use, overall satisfaction) after mono- or bilateral implantation of two presbyopia-correcting intraocular lenses (IOL)—the Liberty® 677MY or the AT LISA® tri 839M—in 50 eyes of 25 cataract patients. Clinical outcomes were assessed 3 and 12 months postoperatively. Eighty-nine percent of eyes implanted with the Liberty IOL and 59% of eyes implanted with the AT LISA IOL achieved a refractive outcome ±0.5 diopters of the target (emmetropia). Refractive outcomes were stable with both lenses. The proportions of eyes with 20/20 uncorrected distance visual acuity (UDVA) and 20/20 uncorrected near visual acuity (UNVA) were higher in the Liberty group than in the AT LISA group (UDVA: 56% vs. 41%; UNVA: 83% vs. 66%). Optical quality assessment results were comparable for the two IOLs. Superior photopic contrast sensitivity was found with the Liberty lens. The rate of Nd:YAG capsulotomy at the 12-month follow-up was 16.7% in the Liberty group and 40.6% for the AT LISA IOL. Considering that both lenses are made from the same material, we propose that the noted differences in clinical outcomes may derive from differences in design and optical surface between the two IOLs.
Collapse
|
27
|
Xiang Y, Jin R, Zhang Y, Li K, Liu G, Song X, Wang Y, Nie Y. Foldable Glistening-Free Acrylic Intraocular Lens Biomaterials with Dual-Side Heterogeneous Surface Modification for Postoperative Endophthalmitis and Posterior Capsule Opacification Prophylaxis. Biomacromolecules 2021; 22:3510-3521. [PMID: 34288655 DOI: 10.1021/acs.biomac.1c00582] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Hydrophobic acrylic intraocular lenses (IOLs) are widely used in cataract treatment for posterior capsule opacification (PCO) prophylaxis. However, undesired glistening and postoperative endophthalmitis are two major potential risks. Hence, a series of poly(2-phenoxyethyl methacrylate-co-2-phenoxyethyl acrylate-co-2-ethylhexyl methacrylate) (PPPE) acrylic IOL materials were synthesized for "glistening-free" optimization. The selected PPPE with 2% 2-ethylhexyl methacrylate showed excellent optical, foldable, and thermomechanical properties. The anterior surface of PPPE was coated with polydopamine followed by gentamycin conjugation (PDA/GS). It inhibited bacterial adhesion by 74% and decreased the biofilm thickness by 87%. In inflammatory mimicking conditions, bacterial proliferation was restrained, with acidic-dependent GS release behavior. The surface of PPPE toward the posterior capsule remained hydrophobic. It was conducive to human lens epithelial cell adhesion, collagen IV and fibronectin adsorption, and the following "sealed sandwich structure" formation. In summary, the PPPE with a dual-side heterogeneous surface displayed good application prospects in postoperative endophthalmitis and PCO prevention.
Collapse
Affiliation(s)
- Yang Xiang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| | - Rongrong Jin
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| | - Ying Zhang
- Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu 610065, China
| | - Kaijun Li
- The Key Laboratory of Leather Chemistry and Engineering of Ministry of Education, College of Biomass Science and Engineering, Sichuan University, Chengdu 610065, China
| | - Gongyan Liu
- The Key Laboratory of Leather Chemistry and Engineering of Ministry of Education, College of Biomass Science and Engineering, Sichuan University, Chengdu 610065, China
| | - Xu Song
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China.,NMPA Key Laboratory for Quality Research and Control of Tissue Regenerative Biomaterial & Institute of Regulatory Science for Medical Devices & NMPA Research Base of Regulatory Science for Medical Devices, Sichuan University, Chengdu 610065, China
| | - Yunbing Wang
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| | - Yu Nie
- National Engineering Research Center for Biomaterials, Sichuan University, Chengdu 610065, China
| |
Collapse
|
28
|
Kymionis GD, Kim J, Petrelli M, Grentzelos MA, Hashemi K, Wagnières G. Intraocular Lens Refractive Index and Its Impact on External Surface Reflections. J Refract Surg 2021; 37:398-402. [PMID: 34170772 DOI: 10.3928/1081597x-20210310-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
PURPOSE To determine and compare the origin of the external surface reflections produced by commonly used intraocular lenses (IOLs). METHODS The specular reflection taking place at the anterior surface of eight types of IOLs (IOL power = 22.00 diopters [D]) with different refractive indices (RIs), optical design, and ultraviolet and blue light-filtering function were measured. The experimental set-up included a laser beam light source (3.5 mW, 532 nm) and a saline-filled model eye containing the IOL to be examined. External surface reflections were measured using a power meter, and the IOL surface reflectance (%) was compared among the eight IOLs investigated. RESULTS External reflections from the anterior surface of the studied implants increased as the RI of the IOL material increased. The IOL models composed of high RI material (RI = 1.56 ± 0.02) were found to have a more than threefold higher external surface reflections compared to those with low RI (RI = 1.45 ± 0.02). Ultraviolet or blue light-filtering functions showed no significant correlation with the external reflectance. CONCLUSIONS IOLs with a high RI are associated with external surface reflections that are more than threefold higher than those with lower RI. The "cat's eye" phenomenon seen in pseudophakic eyes by an outside observer strongly depends on the RI, but is independent of the filter incorporated in the IOL. [J Refract Surg. 2021;37(6):398-402.].
Collapse
|
29
|
Factors Affecting Posterior Capsule Opacification in the Development of Intraocular Lens Materials. Pharmaceutics 2021; 13:pharmaceutics13060860. [PMID: 34200928 PMCID: PMC8230425 DOI: 10.3390/pharmaceutics13060860] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Revised: 06/03/2021] [Accepted: 06/07/2021] [Indexed: 01/01/2023] Open
Abstract
Posterior capsule opacification (PCO) is the most common complication arising from the corrective surgery used to treat cataract patients. PCO arises when lens epithelial cells (LEC) residing in the capsular bag post-surgery undergo hyper-proliferation and transdifferentiation into myofibroblasts, migrating from the posterior capsule over the visual axis of the newly implanted intraocular lens (IOL). The developmental pathways underlying PCO are yet to be fully understood and the current literature is contradictory regarding the impact of the recognised risk factors of PCO. The aim of this review is firstly to collate the known biochemical pathways that lead to PCO development, providing an up-to-date chronological overview from surgery to established PCO formation. Secondly, the risk factors of PCO are evaluated, focussing on the impact of IOLs’ properties. Finally, the latest experimental model designs used in PCO research are discussed to demonstrate the ongoing development of clinical PCO models, the efficacy of newly developed IOL technology, and potential therapeutic interventions. This review will contribute to current PCO literature by presenting an updated overview of the known developmental pathways of PCO, an evaluation of the impact of the risk factors underlying its development, and the latest experimental models used to investigate PCO. Furthermore, the review should provide developmental routes for research into the investigation of potential therapeutic interventions and improvements in IOL design in the aid of preventing PCO for new and existing patients.
Collapse
|
30
|
Bhattacharjee H, Buragohain S, Javeri H, Das D, Bhattacharjee K. Delayed postoperative opacification of three hydrophobic acrylic intraocular lens: A scanning electron microscopic and energy dispersive spectroscopic study. Indian J Ophthalmol 2021; 69:1103-1107. [PMID: 33913842 PMCID: PMC8186658 DOI: 10.4103/ijo.ijo_2749_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Purpose: The aim of this study was to report scanning electron microscopic (SEM) and energy dispersive spectroscopic (EDS) findings of three specimens of opaque hydrophobic acrylic intraocular lens (IOL) explanted in delayed postoperative period for visual indications. Methods: Clinical data and photographs from each subject were obtained. Explanted IOLs were examined under gross and light microscopy followed by SEM coupled with EDS. Results: All three subjects underwent IOL implantation following senile cataract extraction at an average age of 64.3 ± 0.3 years, and the IOLs were in situ for a duration of 11.3 ± 4.04 years. The IOL explantation and exchange were done due to late postoperative opacification of the IOL and significant visual deterioration. The milky iridescent opacity affected the full thickness of IOL optics in the first two specimens and in the third only two surfaces were involved. SEM detected surface cracks in the first specimen, typical conglumated surface, pores and accumulation of crystals with surface deposit of nano-particles on the second specimen and uneven surface erosion in the third specimen. SEM detected mainly sodium (Na) and chloride (Cl) spikes. All patients recovered normal vision following IOL exchange. Conclusion: SEM features of the IOL optics and absence of calcium and phosphate spikes in EDS and other findings were consistent and suggestive of hydrolytic biodegradation of hydrophobic acrylic IOL polymer in ocular media and was responsible for delayed postoperative opacification of the hydrophobic IOLs and visual loss.
Collapse
Affiliation(s)
| | | | - Henal Javeri
- Sri Sankaradeva Nethralaya, Guwahati, Assam, India
| | - Dipankar Das
- Sri Sankaradeva Nethralaya, Guwahati, Assam, India
| | | |
Collapse
|
31
|
Wormstone IM, Damm NB, Kelp M, Eldred JA. Assessment of intraocular lens/capsular bag biomechanical interactions following cataract surgery in a human in vitro graded culture capsular bag model. Exp Eye Res 2021; 205:108487. [PMID: 33571531 DOI: 10.1016/j.exer.2021.108487] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 01/22/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
Intraocular lenses (IOLs) are implanted during cataract surgery. For optimum results, stable positioning of the IOL in the capsular bag is important. Wound-healing events following cataract surgery lead to modification of the capsular bag and secondary visual loss due to posterior capsule opacification. At present, it is unclear how these biological events can affect stability of the IOL within the capsular bag. In the present study, a human in vitro graded culture capsular bag model was the experimental system. Capsulorhexis and lens extraction performed on human donor eyes generated suspended capsular bags (5 match-paired experiments). Preparations were secured by pinning the ciliary body to a silicone ring and maintained in 6 mL of medium for 84 days using a graded culture system: days 1-3, 5% human serum and 10 ng/mL transforming growth factor β (TGFβ2); days 4-7, 2% human serum and 1 ng/mL TGFβ2; days 8-14, 1% human serum and 0.1 ng/mL TGFβ2; days 15-84, serum-free Eagle's minimum essential medium (EMEM). A CT LUCIA 611PY IOL was implanted in all preparations. Quantitative measures were determined from whole bag images captured weekly. Images were registered using FIJI and analysed in ImageJ to determine capsular bag area; distortion; angle of contact; haptic stability; capsulorhexis area; and a fusion footprint associated with connection between the anterior and posterior capsules. Cell coverage and light scatter were quantified at end-point. The transdifferentiation marker, α-SMA was assessed by immunocytochemistry. Immediately following surgery, distortion of the capsular bag was evident, such that a long axis is generated between haptics relative to the non-haptic regions (short axis). The angle of contact between the haptics and the peripheral bag appeared inversely correlated to capsular bag area. Growth on the peripheral posterior capsule was observed 1 week after surgery and beneath the IOL within 1 month. As coverage of the posterior capsule progressed this was associated with matrix contraction/wrinkles of both the central posterior capsule and peripheral capsular bag. Cells on the central posterior capsule expressed αSMA. Fusion footprints formed in non-haptic regions of the peripheral bag and progressively increased over the culture period. Within and at the edge of the fusion footprint, refractive structures resembling lens fibre cells and Elschnig's pearls were observed. Cell attachment to the IOL was limited. An impression in the posterior capsule associated with the CT LUCIA 611PY optic edge was evident; cell density was much greater peripheral to this indent. Wound-healing events following surgery reduced capsular bag area. This was associated with the long/short axis ratio and angle of contact increasing with time. In summary, we have developed a human capsular bag model that exhibits features of fibrotic and regenerative PCO. The model permits biomechanical information to be obtained that enables better understanding of IOL characteristics in a clinically relevant biological system. Throughout culture the CT LUCIA 611PY appeared stable in its position and capsular bag modifications did not change this. We propose that the CT LUCIA 611PY optic edge shows an enhanced barrier function, which is likely to provide better PCO management in patients.
Collapse
Affiliation(s)
- I Michael Wormstone
- School of Biological Sciences, University of East Anglia, Norwich, NR4 7TJ, UK.
| | - Niklas B Damm
- ZEISS Ophthalmic Devices, Carl Zeiss Meditec AG, 10589, Berlin, Germany
| | - Martin Kelp
- ZEISS Ophthalmic Devices, Carl Zeiss Meditec AG, 10589, Berlin, Germany
| | - Julie A Eldred
- School of Biological Sciences, University of East Anglia, Norwich, NR4 7TJ, UK
| |
Collapse
|
32
|
Fouling in ocular devices: implications for drug delivery, bioactive surface immobilization, and biomaterial design. Drug Deliv Transl Res 2021; 11:1903-1923. [PMID: 33454927 DOI: 10.1007/s13346-020-00879-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/24/2020] [Indexed: 10/22/2022]
Abstract
The last 30 years has seen a proliferation of research on protein-resistant biomaterials targeted at designing bio-inert surfaces, which are prerequisite for optimal performance of implantable devices that contact biological fluids and tissues. These efforts have only been able to yield minimal results, and hence, the ideal anti-fouling biomaterial has remained elusive. Some studies have yielded biomaterials with a reduced fouling index among which high molecular weight polyethylene glycols have remained dominant. Interestingly, the field of implantable ocular devices has not experienced an outflow of research in this area, possibly due to the assumption that biomaterials tested in other body fluids can be translated for application in the ocular space. Unfortunately, progression in the molecular understanding of many ocular conditions has brought to the fore the need for treatment options that necessitates the use of anti-fouling biomaterials. From the earliest implanted horsehair and silk seton for glaucoma drainage to the recent mini telescopes for sight recovery, this review provides a concise incursion into the gradual evolution of biomaterials for the design of implantable ocular devices as well as approaches used to overcome the challenges with fouling. The implication of fouling for drug delivery, the design of immune-responsive biomaterials, as well as advanced surface immobilization approaches to support the overall performance of implantable ocular devices are also reviewed.
Collapse
|
33
|
Moshirfar M, Thomson AC, Thomson RJ, Martheswaran T, McCabe SE. Refractive enhancements for residual refractive error after cataract surgery. Curr Opin Ophthalmol 2021; 32:54-61. [PMID: 33122488 DOI: 10.1097/icu.0000000000000717] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW Advances in cataract surgery have allowed surgeons to achieve superior refractive outcomes but have also led to higher patient expectations. Despite ever-evolving technology, residual refractive errors still occur. Postcataract refractive enhancements may be required to deliver satisfactory visual outcomes. This review aims to discuss the potential causes of residual refractive errors and the various enhancement modalities to correct them. RECENT FINDINGS A thorough preoperative workup to detect and address underlying pathologic causes of impaired vision should be performed prior to enhancement or corrective procedures. Corneal-based procedures are the safest and most accurate methods of correcting mild cases of residual refractive error. Hyperopic, high myopic, and high astigmatic errors are best managed with lens-based enhancements. Piggyback intraocular lenses (IOLs) are safer and more effective compared with IOL exchange. Toric IOL rotation and IOL exchange are ideally performed in the early postoperative period. SUMMARY A multitude of options exist for effective correction of residual refractive errors. The choice on how to best manage these patients depends on many factors such as the cause of refractive error, type of IOL used, ocular comorbidities, and patient preference.
Collapse
Affiliation(s)
- Majid Moshirfar
- Hoopes Vision Research Center, Hoopes Vision, Draper
- Department of Ophthalmology and Visual Sciences, John A. Moran Eye Center, University of Utah School of Medicine, Salt Lake City
- Utah Lions Eye Bank, Murray, Utah
| | - Andrew C Thomson
- McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, Texas
| | - Robert J Thomson
- McGovern Medical School at The University of Texas Health Science Center at Houston, Houston, Texas
| | - Tanisha Martheswaran
- Department of Stem Cell and Regenerative Biology, Harvard University, Cambridge, Massachusetts, USA
| | | |
Collapse
|
34
|
Pérez-Gracia J, Ávila FJ, Ares J, Vallés JA, Remón L. Misalignment and tilt effect on aspheric intraocular lens designs after a corneal refractive surgery. PLoS One 2020; 15:e0243740. [PMID: 33315894 PMCID: PMC7735572 DOI: 10.1371/journal.pone.0243740] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2020] [Accepted: 11/26/2020] [Indexed: 12/19/2022] Open
Abstract
PURPOSE To numerically evaluate and compare the tolerance to misalignment and tilt of aspheric intraocular lenses (IOLs) designed for three eyes: with standard cornea and with simulated corneas after myopic and hyperopic laser ablation surgery. METHODS Three aspheric IOLs of +20.00 diopter (D) with different spherical aberration (SA) ([Formula: see text]) values have been designed using a theoretical model eye. Drastic changes on the theoretical eye anterior corneal asphericity have been performed to simulate myopic and hyperopic refractive surgeries. The effect of IOL misalignment and tilt on the image quality has been evaluated using a commercial optical software design for the three eye models. Image quality was assessed from the modulation transfer function (MTF), root mean square (RMS) values of defocus, astigmatism, coma and spherical aberration ([Formula: see text]), and retinal images obtained from a visual simulator using an aleatory optotype of 0.00 LogMar visual acuity (VA). RESULTS IOL misalignment and tilt reduced MTF values in general, and increased wavefront aberrations errors. Aberration-free IOLs maintained best the MTF values when misalignments were applied, together with good on-axis optical quality. IOLs with negative SA ([Formula: see text]) correction decreased the MTF value under 0.43 for misalignments values higher than 0.50 mm with the three corneas. The effect of misalignment on RMS astigmatism and coma was correlated with the IOL SA ([Formula: see text]) and with the three corneas. CONCLUSIONS This theoretical study shows that the largest degradation in image quality arises for the IOL with the highest amount of spherical aberration ([Formula: see text]). Moreover, it has been found that the aspherical design has a more influential role in misalignment tolerance than in tilt tolerance.
Collapse
Affiliation(s)
- Jesús Pérez-Gracia
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Francisco J. Ávila
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Jorge Ares
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Juan A. Vallés
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Laura Remón
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| |
Collapse
|
35
|
Grzybowski A, Markeviciute A, Zemaitiene R. A narrative review of intraocular lens opacifications: update 2020. ANNALS OF TRANSLATIONAL MEDICINE 2020; 8:1547. [PMID: 33313292 PMCID: PMC7729367 DOI: 10.21037/atm-20-4207] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The opacifications of intraocular lenses (IOLs) can significantly impact patients visual quality. Despite the identification of specific risk factors, manufacturing changes, opacifications are not eliminated. Likewise, more attention in recent studies was paid to possible new risk factors, however one of the most important purposes of the studies remains opacifications effect on visual performance, which could be disturbed in different aspects. The aim of this review is to discuss the main risk factors of IOLs opacification in particular IOL types, and its impact on vision quality. Different risk factors were discussed in the study, including the material of IOLs, the impact of the breakdown of blood-aqueous barrier (BAB), and certain surgeries that can be associated with opacification formation. Glistenings occur more often in a hydrophobic material, however, the changes in water content of the IOLs can significantly reduce the formation of glistenings. The studies showed a significant effect of intraocular injection of exogenous air or gas during Descemet-stripping endothelial keratoplasty, Descemet-stripping automated endothelial keratoplasty, Descemet membrane endothelial keratoplasty, and pars plana vitrectomy on calcification formation. It raises a concern, as the incidence of these surgeries is increasing. Visual acuity decreases significantly after the calcification in IOLs occurs, and it usually causes IOLs exchange. However, disability glare seems to be more affected in patients with IOLs, which were affected by glistenings than visual acuity. Disability glare is associated with increased levels of straylight, which was widely evaluated in recent studies and it was reported to be a susceptible measurement to detect the presence of IOLs pathology. For future researches, it should be noticed that disability glare and straylight are more appropriate in evaluating IOLs opacification effect on visual quality than visual acuity. While reviewing the main risk factors of IOLs opacifications particular attention must be paid on calcification occurrence in hydrophilic acrylic IOLs after surgeries with intraocular injection of exogenous air or gas.
Collapse
Affiliation(s)
- Andrzej Grzybowski
- Department of Ophthalmology, University of Warmia and Mazury, Olsztyn, Poland.,Institute for Research in Ophthalmology, Poznan, Poland
| | - Agne Markeviciute
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Reda Zemaitiene
- Department of Ophthalmology, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
36
|
Affiliation(s)
- Andrzej Grzybowski
- Professor of Ophthalmology, Department of Ophthalmology, University of Warmia and Mazury, Olsztyn, Poland; Institute for Research in Ophthalmology, Poznan, Poland
| |
Collapse
|
37
|
Ling R, Borkenstein EM, Borkenstein AF. Evaluation of Nd:YAG Laser Capsulotomy Rates in a Real-Life Population. Clin Ophthalmol 2020; 14:3249-3257. [PMID: 33116375 PMCID: PMC7569058 DOI: 10.2147/opth.s276329] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 10/05/2020] [Indexed: 11/23/2022] Open
Abstract
Objective The objective of this study was to assess the rate of posterior capsule opacification (PCO), under “real-life” conditions, as measured by rates of Nd:YAG laser intervention, rather than from a controlled study from which patients with conditions predisposing to PCO have been excluded. Methods and Analysis This was a retrospective, multicenter study in an unselected consecutive cohort of patients undergoing surgery for senile cataract. Patients aged 18 years and older, previously implanted with the CT LUCIA 611P IOL, were contacted at 12, 18 and 24 months to ascertain if they had received Nd:YAG laser treatment. There was an additional assessment at 36 months at the Austrian centre. Results A total of 200 patients were recruited at two centers. Laser capsulotomy rates were 4.5% at 1 year and 10% by year 2 and 12% by year 3. Three Nd:YAG capsulotomies, carried out at other external centers, were performed for reasons other than PCO, including astigmatism, epiretinal membrane and ARMD. If these patients are excluded, the true rate of Nd:YAG carried out for PCO at 1 year was 3.5% and at 2 years was 8.5%. Conclusion It is critical to ensure that Nd:YAG capsulotomies are being performed only for the correct clinical reason. Carrying out unnecessary procedures places the patient at risk of adverse events, is a cost to the healthcare system, and is likely to have no direct visual benefit for the patient. In PCO studies, it should be a requirement to document the fibrosis grade to confirm that Nd:YAG capsulotomy was correctly indicated.
Collapse
Affiliation(s)
- Roland Ling
- The Medical Eye Clinic, Royal Devon and Exeter Hospital, Exeter, UK
| | - Eva-Maria Borkenstein
- Privatklinik der Kreuzschwestern Graz, Private Practice Borkenstein & Borkenstein, Graz, Austria
| | - Andreas F Borkenstein
- Privatklinik der Kreuzschwestern Graz, Private Practice Borkenstein & Borkenstein, Graz, Austria
| |
Collapse
|
38
|
Poleva RP, Ermolaev AP, Hderi K, Levitskiy YV. [Functional rehabilitation of a patient with central opacification of the intraocular lens optic (clinical case)]. Vestn Oftalmol 2020; 136:237-240. [PMID: 33063971 DOI: 10.17116/oftalma2020136052237] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The authors present a clinical case of central opacification of the intraocular lens (IOL) optic associated with a significant uncorrectable visual acuity decrease. Due to high surgical risks of IOL exchange, corectopia was achieved through sectoral laser photomydriasis. Stable dilation of the lower nasal sector of the pupil enabled the optical zone to be shifted outside the opaque area of the IOL. As shown by the perimetry results, the visual field borders enlarged through sectoral laser photomydriasis were comparable with the topography of the asymmetrically dilated pupil.
Collapse
Affiliation(s)
- R P Poleva
- Research Institute of Eye Diseases, Moscow, Russia
| | - A P Ermolaev
- Research Institute of Eye Diseases, Moscow, Russia
| | - K Hderi
- Research Institute of Eye Diseases, Moscow, Russia
| | | |
Collapse
|
39
|
Topete A, Tang J, Ding X, Filipe HP, Saraiva JA, Serro AP, Lin Q, Saramago B. Dual drug delivery from hydrophobic and hydrophilic intraocular lenses: in-vitro and in-vivo studies. J Control Release 2020; 326:245-255. [DOI: 10.1016/j.jconrel.2020.07.020] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 07/10/2020] [Accepted: 07/13/2020] [Indexed: 11/27/2022]
|
40
|
Wormstone IM, Wormstone YM, Smith AJO, Eldred JA. Posterior capsule opacification: What's in the bag? Prog Retin Eye Res 2020; 82:100905. [PMID: 32977000 DOI: 10.1016/j.preteyeres.2020.100905] [Citation(s) in RCA: 78] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 09/18/2020] [Accepted: 09/21/2020] [Indexed: 12/18/2022]
Abstract
Cataract, a clouding of the lens, is the most common cause of blindness in the world. It has a marked impact on the wellbeing and productivity of individuals and has a major economic impact on healthcare providers. The only means of treating cataract is by surgical intervention. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior capsule and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens (IOL). The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. Lens epithelial cells, however, remain attached to the anterior capsule, and in response to surgical trauma initiate a wound-healing response that ultimately leads to light scatter and a reduction in visual quality known as posterior capsule opacification (PCO). There are two commonly-described forms of PCO: fibrotic and regenerative. Fibrotic PCO follows classically defined fibrotic processes, namely hyperproliferation, matrix contraction, matrix deposition and epithelial cell trans-differentiation to a myofibroblast phenotype. Regenerative PCO is defined by lens fibre cell differentiation events that give rise to Soemmerring's ring and Elschnig's pearls and becomes evident at a later stage than the fibrotic form. Both fibrotic and regenerative forms of PCO contribute to a reduction in visual quality in patients. This review will highlight the wealth of tools available for PCO research, provide insight into our current knowledge of PCO and discuss putative management of PCO from IOL design to pharmacological interventions.
Collapse
Affiliation(s)
- I M Wormstone
- School of Biological Sciences, University of East Anglia, Norwich, UK.
| | - Y M Wormstone
- School of Biological Sciences, University of East Anglia, Norwich, UK
| | - A J O Smith
- School of Biological Sciences, University of East Anglia, Norwich, UK
| | - J A Eldred
- School of Biological Sciences, University of East Anglia, Norwich, UK
| |
Collapse
|
41
|
Pérez-Gracia J, Varea A, Ares J, Vallés JA, Remón L. Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors. PLoS One 2020; 15:e0232546. [PMID: 32365135 PMCID: PMC7197786 DOI: 10.1371/journal.pone.0232546] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2019] [Accepted: 04/16/2020] [Indexed: 12/16/2022] Open
Abstract
PURPOSE To evaluate and compare the effect of misalignment and tilt on the optical performance of different aspheric intraocular lens (IOL) designs. METHODS Three aspheric IOLs with a different quantity of spherical aberration (SA) have been designed and the effect of IOL misalignment and tilt on the imaging quality of an eye model has been numerically assessed using a commercial optical design software. The prototypes have been manufactured by lathe turning and tested in vitro using the same optical bench (PMTF, Lambda-X) that complies with International Organization for Standardization standard 11979-2 requirements. Image quality was evaluated from the modulation transfer functions (MTFs), through-focus modulation transfer functions (TF-MTFs), root mean square (RMS) values of defocus, astigmatism and coma, and images of the United States Air Force (USAF) target were taken. A comparison with the optical performance of spherical IOLs has also been performed. RESULTS Intraocular lens misalignment and tilt increased wavefront aberrations; the effect of misalignment on root mean square (RMS) astigmatism and coma was positively correlated with the spherical aberration of the IOL. Aberration-free IOLs showed the highest MTF for all misalignment values and for IOLs with negative SA correction the MTF decays below 0.43 when they are decentered 0.50 mm. CONCLUSIONS Aspherical IOLs are more sensitive than spherical IOLs to misalignment or tilt, depending on their SA correction. The optical degradation caused by IOL misalignment had a greater effect on IOL designs with a higher amount of negative spherical aberration. In contrast, the effect of tilt on the optical performance was less sensitive to the IOL design.
Collapse
Affiliation(s)
- Jesús Pérez-Gracia
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Alejandra Varea
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Jorge Ares
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Juan A. Vallés
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| | - Laura Remón
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, Spain
| |
Collapse
|
42
|
Spiezio V, Walker BN, Calogero D, Ilev IK. Experimental and analytical quantification of light scattering from vacuoles in intraocular lenses. J Cataract Refract Surg 2020; 46:762-773. [PMID: 32358273 PMCID: PMC10824253 DOI: 10.1097/j.jcrs.0000000000000167] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To develop an advanced test methodology for quantification of scattered light from intraocular lenses (IOLs) and to evaluate the correlation between IOL vacuole characteristics and measured scattered light. SETTING U.S. Food and Drug Administration, Optical Therapeutics and Medical Nanophotonics Laboratory, Silver Spring, Maryland, USA. DESIGN Experimental and analytical study. METHODS Twenty-four IOLs containing vacuoles were evaluated using a digital microscopy approach for identifying and characterizing the vacuoles present. A scanning light scattering profiler (SLSP) was used to evaluate and quantify the amount of scattered light from each IOL and from a 25th control IOL without any vacuoles. A variety of IOLs and vacuoles were also modeled in a Zemax simulation of the SLSP, and the simulated scattered light was modeled. RESULTS The scattered light as measured with SLSP was well correlated with vacuole characteristics, specifically density and size, as measured under the digital microscope for the 24 vacuole-containing IOLs. Additional correlations were found between vacuole sizes, orientations, and the angle at which light was scattered most severely. These correlations were also present in the Zemax model. CONCLUSIONS Vacuole optical characteristics can be well correlated with measured scatter, demonstrating an ability to predict scattered light based solely on microscope evaluation. Furthermore, the quantitative amount of scatter predicted with Zemax simulations trended closely with the experimentally measured trends.
Collapse
Affiliation(s)
- Vincent Spiezio
- From the Optical Therapeutics and Medical Nanophotonics Laboratory, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health (Spiezio, Ilev), and Office of Device Evaluation, Center for Devices and Radiological Health (Walker, Calogero), U.S. Food and Drug Administration, Silver Spring, Maryland, USA
| | | | | | | |
Collapse
|
43
|
Ren X, Wang Y, Wang D, Wu B, Wu L, Xu Y, Yang J, Chen Z, Li X. A novel standardized test system to evaluate dynamic visual acuity post trifocal or monofocal intraocular lens implantation: a multicenter study. Eye (Lond) 2020; 34:2235-2241. [PMID: 32024972 DOI: 10.1038/s41433-020-0780-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2019] [Accepted: 01/05/2020] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVES To compare the dynamic visual acuity (DVA) following implantation of trifocal with monofocal intraocular lenses (IOL) and using a novel test system. METHODS The present research was a retrospective, multicenter clinical study. Two hundred and ten eyes of 149 patients that underwent cataract phacoemulsification and IOL implantation were enrolled. One hundred and ten eyes of patients received trifocal (AT LISA tri839MP, Carl Zeiss Meditec, Germany) and 100 eyes received monofocal (Tecnis ZCB00, Abbott, United States) lenses and were evaluated 3 months after implantation. Outcome measures included monocular uncorrected distance (UDVA), intermediate (UIVA) and near (UNVA) visual acuity and best corrected distance visual acuity (BCDVA; logMAR units); contrast sensitivity under photopic, mesopic, with glare conditions; and dynamic visual acuity using a self-developed system. RESULTS There was no statistically significant difference in baseline characteristics between groups. Monocular UDVA, UIVA, and UNVA were significantly better (all p < 0.001) in the trifocal IOL group, but not BCDVA. The trifocal IOL group showed better contrast sensitivity under photopic, mesopic, with or without glare conditions (p < 0.05) and statistically significantly better dynamic vision at 15, 30, 60, and 90 degrees per second (dps) compared with the monofocal group (all p < 0.001). The strength of positive association only between UIVA and dynamic visual acuity increased as the velocity increased, but not UDVA or UNVA. CONCLUSIONS Diffractive trifocal IOL provides better postoperative full range vision acuity, contrast sensitivity, and dynamic vision compared with monofocal IOLs. And intermediate visual acuity is increasingly associated with DVA as the velocity increasing.
Collapse
Affiliation(s)
- Xiaotong Ren
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Yuexin Wang
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | - Dengting Wang
- Department of Ophthalmology, Gansu Province Hospital Rehabilitation Center, Gansu, China
| | - Baohua Wu
- Lanzhou Bright Eye Hospital, Gansu, China
| | - Lei Wu
- Chengdu Aier Eye Hospital, Sichuan, China
| | | | - Jiarui Yang
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China
| | | | - Xuemin Li
- Department of Ophthalmology, Peking University Third Hospital, Beijing, China.
| |
Collapse
|
44
|
Ionizing Radiation for Preparation and Functionalization of Membranes and Their Biomedical and Environmental Applications. MEMBRANES 2019; 9:membranes9120163. [PMID: 31816943 PMCID: PMC6950004 DOI: 10.3390/membranes9120163] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2019] [Revised: 11/27/2019] [Accepted: 11/28/2019] [Indexed: 01/31/2023]
Abstract
The use of ionizing radiation processing technologies has proven to be one of the most versatile ways to prepare a wide range of membranes with specific tailored functionalities, thus enabling them to be used in a variety of industrial, environmental, and biological applications. The general principle of this clean and environmental friendly technique is the use of various types of commercially available high-energy radiation sources, like 60Co, X-ray, and electron beam to initiate energy-controlled processes of free-radical polymerization or copolymerization, leading to the production of functionalized, flexible, structured membranes or to the incorporation of functional groups within a matrix composed by a low-cost polymer film. The present manuscript describes the state of the art of using ionizing radiation for the preparation and functionalization of polymer-based membranes for biomedical and environmental applications.
Collapse
|
45
|
Shihan MH, Novo SG, Duncan MK. Cataract surgeon viewpoints on the need for novel preventative anti-inflammatory and anti-posterior capsular opacification therapies. Curr Med Res Opin 2019; 35:1971-1981. [PMID: 31328581 PMCID: PMC6995282 DOI: 10.1080/03007995.2019.1647012] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Purpose: To determine cataract surgeon viewpoints on the efficacy of available therapies/preventatives for two common sequelae of cataract surgery: inflammation and posterior capsular opacification (PCO). Methods: Cataract surgeons practicing worldwide specializing in adult, pediatric and veterinary patients were interviewed between March and August 2018. Results: Ocular inflammation following cataract surgery is treated by either corticosteroids and/or nonsteroidal anti-inflammatories (NSAIDs). Adult and pediatric cataract surgeons are satisfied with current treatments whereas this inflammation is still considered a problem by some in veterinary practice due to its slow resolution. Yttrium-aluminum-garnet (YAG) laser therapy is the PCO treatment of choice for adult cataract surgeons and they are generally pleased with its outcome. However, pediatric cataract surgeons find YAG problematic, especially in patients under 6 years of age, and invasive surgery is often needed to correct PCO/visual axis opacification (VAO). Veterinary ophthalmologists report that YAG is not effective for PCO in animals, especially dogs, due to the density of the fibrotic plaques; 86% of adult and 100% of veterinary and pediatric cataract surgeons surveyed agree that effective anti-PCO therapeutics would improve clinical care. Conclusions: Surgeons treating human patients are pleased with the available treatments for ocular inflammation following cataract surgery, although some veterinary ophthalmologists disagree. The surgeons surveyed agree that PCO/VAO remains an unsolved problem in pediatric and veterinary cataract surgery while the long-term outcome of adult cataract surgery could be improved by additional attention to this issue.
Collapse
Affiliation(s)
- Mahbubul H Shihan
- Department of Biological Sciences, The University of Delaware , Newark , DE , USA
| | - Samuel G Novo
- Department of Biological Sciences, The University of Delaware , Newark , DE , USA
| | - Melinda K Duncan
- Department of Biological Sciences, The University of Delaware , Newark , DE , USA
| |
Collapse
|
46
|
5 year incidence of YAG capsulotomy and PCO after cataract surgery with single-piece monofocal intraocular lenses: a real-world evidence study of 20,763 eyes. Eye (Lond) 2019; 34:960-968. [PMID: 31616057 PMCID: PMC7182577 DOI: 10.1038/s41433-019-0630-9] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Revised: 08/07/2019] [Accepted: 09/03/2019] [Indexed: 11/09/2022] Open
Abstract
OBJECTIVES To evaluate the 3- and 5-year incidence of posterior capsule opacification (PCO) and neodymium-doped yttrium aluminium garnet (Nd:YAG) capsulotomy in patients following cataract surgery, comparing results for different single-piece acrylic hydrophilic and hydrophobic monofocal intraocular lens (IOL) models and other patient factors. PATIENTS AND METHODS Electronic medical record data collected from seven United Kingdom (UK) National Health Service (NHS) ophthalmology clinics for routine, age-related (≥65 years) cataract surgeries that implanted single-piece acrylic monofocal IOLs during 2010-2013 were used to calculate 3- and 5-year incidence of Nd:YAG and PCO. IOL models of Alcon Acrysof, AMO Tecnis, Bausch & Lomb (B & L) Akreos, LenStec Softec, and Rayner Flex were analyzed. Pairwise comparisons were conducted between AcrySof IOLs and other IOLs using Bonferroni adjustment for multiplicity. Multivariate analyses were conducted adjusting for known confounders. RESULTS The incidence of Nd:YAG capsulotomy ranged between 2.4-12.6% at 3 years and 5.8-19.3% at 5 years post-cataract surgery. Similarly, the incidence of PCO ranged between 4.7-18.6% at 3 years and 7.1-22.6% at 5 years. When comparing all of the single-piece IOLs, AcrySof demonstrated the lowest incidence rates for both PCO and Nd:YAG (P < 0.001 for each comparison). From adjusted logistic regression analysis, AcrySof were associated with lower 3- and 5-year odds of Nd:YAG and PCO incidence. CONCLUSIONS Following cataract surgery with single-piece monofocal IOLs different incidence rates of PCO were observed with different IOLs. AcrySof IOLs were associated with significantly lower incidence of PCO requiring Nd:YAG treatment over periods of 3 and 5 years.
Collapse
|
47
|
Quantitative Multiparameter Evaluation of Vacuoles in Intraocular Lenses Employing a High-Magnification Digital Microscopy Method. J Ophthalmol 2019; 2019:7929014. [PMID: 31467695 PMCID: PMC6701293 DOI: 10.1155/2019/7929014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 05/23/2019] [Accepted: 07/09/2019] [Indexed: 11/17/2022] Open
Abstract
As small imperfections with micrometric sizes, fluid-filled vacuoles, also referred to as glistenings, in intraocular lenses (IOLs) have been known to induce significant unwanted light scattering that in several cases presumably cause complaints and sometimes lead to IOL explantation and replacement. This unwanted scatter is of particular concern for patients viewing bright light in reduced-light conditions such as when driving at night, as the scattered light toward the retina can cause temporary blindness. In this study, we have developed and implemented an accurate test methodology based on a high-magnification digital microscopy approach for quantitative multiparameter evaluation and classification of IOL vacuoles depending on their critical optical characteristics including vacuole size, density, shape, and orientation within the IOL material. Using the multiparameter database developed by evaluating vacuole characteristics, we established a classification grading system that can be used to evaluate vacuole effects on light scattering.
Collapse
|
48
|
Risk factors for the occurrence of visual-threatening posterior capsule opacification. J Transl Med 2019; 17:209. [PMID: 31221170 PMCID: PMC6585115 DOI: 10.1186/s12967-019-1956-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Accepted: 06/13/2019] [Indexed: 11/13/2022] Open
Abstract
Background To evaluate the potential risk factor of visual-threatening posterior capsule opacification (PCO) via the analysis of National Health Insurance Research Database in Taiwan. Patients and methods A total of 8571 patients (3767 male and 4804 female) were recruited in the study group and 17,142 patients (7534 male and 9608 female) in the control group. Patients undergoing cataract surgery, acrysof single-piece intraocular lens implantation and Nd:YAG capsulotomy were selected as the study group. After exclusion which aimed to standardize the ocular condition and exclude the possibility that patients undergoing cataract surgery and Nd:YAG capsulotomy in different eyes, each patient in the study group was age-gender matched to two patients undergoing cataract surgery but without Nd:YAG capsulotomy. The demographic data, systemic disease, and ocular co-morbidities were obtained and analyzed. Adjusted odds ratio (OR) of each demographic data and co-morbidities to the development of visual-threatening PCO, and adjusted OR of co-morbidities to visual-threatening PCO develop within 1 year postoperatively. Results The dry eye disease (DED), glaucoma, uveitis, age-related macular degeneration (AMD), hyperlipidemia, peptic ulcer disease and liver disease showed significant crude OR while the DED, glaucoma, AMD, hyperlipidemia and peptic ulcer disease revealed a significant adjusted OR. In the subgroup analysis, the DED, glaucoma, AMD, and hyperlipidemia still illustrated a higher adjusted OR to develop visual-threatening PCO within 1 year after the cataract surgery. Conclusion The DED, glaucoma, AMD, hyperlipidemia and peptic ulcer disease may serve as the risk factor for the developing of visual-threatening PCO.
Collapse
|
49
|
Borkenstein AF, Borkenstein EM. Polarized glasses may help in symptomatic cases of intraocular lens glistenings. CLINICAL OPTOMETRY 2019; 11:57-62. [PMID: 31191065 PMCID: PMC6511652 DOI: 10.2147/opto.s202796] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 04/16/2019] [Indexed: 05/30/2023]
Abstract
Intraocular lens (IOL) glistening is a relatively common phenomenon. Although most of the patients remain asymptomatic, a small percentage of patients can develop unwanted optical side effects. We report 6 symptomatic patients with IOL glistening. All patients underwent an implantation of a hydrophobic acrylic mononofocal, multifocal or toric IOL in external clinics for visually significant cataract at least 6 months prior. Patients had very reasonable corrected visual acuity (0.8-1.0 decimal), but significantly had reduced contrast sensitivity and modulation transfer function, complained of visual phenomena and expressed dissatisfaction with their visual status. Patients indicated the symptoms were not present immediately after surgery, but gradually developed postoperatively. Slit-lamp examination revealed moderate-to-severe glistening in all cases. No other pathology that would be responsible for the visual symptoms was present. Patients reported improvement in side effects with the use of edge filter (blue-light blocking) eyeglasses and polarized sunglasses with an increase in contrast sensitivity by aproximately 1 line on Pelli-Robson chart. The use of specific eyewear seems to be a promising alternative to avoid explant of an IOL in symptomatic patients with glistenings and very good visual acuity. In conclusion, we believe that long-term optical clarity is crucial for the choice of an IOL.
Collapse
|