1
|
Abo-Elsoud AAE, Mohamady EM, Fathi Abdou NES. Thermomechanical aging effects on vertical marginal gap and fracture resistance: a comparative study of Bioflx and traditional pediatric crowns. BMC Oral Health 2024; 24:1334. [PMID: 39487502 PMCID: PMC11529303 DOI: 10.1186/s12903-024-05053-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Accepted: 10/14/2024] [Indexed: 11/04/2024] Open
Abstract
BACKGROUND Various types of crowns are used for full-coverage restoration of primary teeth affected by caries, developmental defects, or after pulp therapy. Prefabricated Stainless Steel and Zirconia crowns are commonly utilized. Bioflx crowns, which blend the properties of Stainless Steel and Zirconia, provide a flexible and aesthetically pleasing alternative. AIM This study aimed to evaluate the vertical marginal gap and fracture resistance of Bioflx pediatric crowns compared to Zirconia and Stainless Steel crowns following thermomechanical aging. METHODS This in-vitro study was conducted using mandibular second primary crowns of three different materials (n = 30). Crowns were divided into three groups; Zirconia crowns group (n = 10, Nu Smile, USA), Bioflx crowns group (n = 10, Nu Smile, USA) and Stainless Steel crowns group (n = 10, Nu Smile, USA). The crowns were cemented onto standardized acrylic resin dies and subjected to thermomechanical aging. Vertical marginal gap measurements were obtained using a USB digital microscope with an integrated camera, while fracture resistance was assessed with a universal testing machine. Data were analyzed for outliers and tested for normality using the Shapiro-Wilk or Kolmogorov-Smirnov tests, with statistical significance set at 0.05. RESULTS Significant differences were observed in the vertical marginal gaps among the groups after cementation and thermomechanical aging (P = 0.013 and P = 0.001, respectively). Zirconia crowns exhibited the largest average marginal gap, followed by Bioflx and Stainless Steel crowns. Stainless steel crowns demonstrated the highest fracture resistance, followed by Bioflx crowns, while Zirconia crowns showed the lowest. CONCLUSIONS Bioflx crowns exhibit the largest vertical marginal gap but show greater fracture resistance compared to Zirconia crowns, although they are still less resistant than Stainless Steel crowns after undergoing thermomechanical aging.
Collapse
Affiliation(s)
- Asmaa Ali Emam Abo-Elsoud
- Pediatric Dentistry, Preventive Dentistry and Dental Public Health, Faculty of Dentistry, Suez Canal University, Ismailia city, Egypt
| | - Eman Mohamed Mohamady
- Dental Biomaterials Department, Faculty of Dentistry, Suez Canal University, Ismailia city, Egypt
| | - Noha El-Sayed Fathi Abdou
- Pediatric Dentistry, Preventive Dentistry and Dental Public Health, Faculty of Dentistry, Aswan University, Aswan city, Egypt.
| |
Collapse
|
2
|
Fatima Balderrama I, Schafer S, El Shatanofy M, Bergamo ETP, Mirsky NA, Nayak VV, Marcantonio Junior E, Alifarag AM, Coelho PG, Witek L. Biomimetic Tissue Engineering Strategies for Craniofacial Applications. Biomimetics (Basel) 2024; 9:636. [PMID: 39451842 PMCID: PMC11506466 DOI: 10.3390/biomimetics9100636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2024] [Revised: 09/21/2024] [Accepted: 10/11/2024] [Indexed: 10/26/2024] Open
Abstract
Biomimetics is the science of imitating nature's designs and processes to create innovative solutions for various fields, including dentistry and craniofacial reconstruction. In these areas, biomimetics involves drawing inspiration from living organisms/systems to develop new materials, techniques, and devices that closely resemble natural tissue structures and enhance functionality. This field has successfully demonstrated its potential to revolutionize craniofacial procedures, significantly improving patient outcomes. In dentistry, biomimetics offers exciting possibilities for the advancement of new dental materials, restorative techniques, and regenerative potential. By analyzing the structure/composition of natural teeth and the surrounding tissues, researchers have developed restorative materials that mimic the properties of teeth, as well as regenerative techniques that might assist in repairing enamel, dentin, pulp, cementum, periodontal ligament, and bone. In craniofacial reconstruction, biomimetics plays a vital role in developing innovative solutions for facial trauma, congenital defects, and various conditions affecting the maxillofacial region. By studying the intricate composition and mechanical properties of the skull and facial bones, clinicians and engineers have been able to replicate natural structures leveraging computer-aided design and manufacturing (CAD/CAM) and 3D printing. This has allowed for the creation of patient-specific scaffolds, implants, and prostheses that accurately fit a patient's anatomy. This review highlights the current evidence on the application of biomimetics in the fields of dentistry and craniofacial reconstruction.
Collapse
Affiliation(s)
- Isis Fatima Balderrama
- Department of Diagnosis and Surgery, School of Dentistry of Araraquara, Sao Paulo State University, Sao Paulo 14801-385, Brazil
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
| | - Sogand Schafer
- Division of Plastic, Reconstructive and Oral Surgery, Children’s Hospital of Philadelphia, Philadelphia, PA 19104, USA
| | - Muhammad El Shatanofy
- Department of Otolaryngology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Edmara T. P. Bergamo
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
- Department of Prosthodontics, NYU Dentistry, New York, NY 10010, USA
| | | | - Vasudev Vivekanand Nayak
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Elcio Marcantonio Junior
- Department of Diagnosis and Surgery, School of Dentistry of Araraquara, Sao Paulo State University, Sao Paulo 14801-385, Brazil
| | - Adham M. Alifarag
- Department of General Surgery, Temple University Hospital System, Philadelphia, PA 19140, USA
| | - Paulo G. Coelho
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, Miami, FL 33136, USA
- Division of Plastic Surgery, DeWitt Daughtry Family Department of Surgery, University of Miami Miller School of Medicine, Miami, FL 33136, USA
| | - Lukasz Witek
- Biomaterials Division, NYU Dentistry, New York, NY 10010, USA
- Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, NY 11201, USA
- Hansjörg Wyss Department of Plastic Surgery, NYU Grossman School of Medicine, New York, NY 10016, USA
| |
Collapse
|
3
|
Alsarani MM, Khan AA, Bautista LSJ, Alsunbul H, Matinlinna JP. Effect of peroxide-free and peroxide-based in-office bleaching on the surface and mechanical properties of CAD/CAM esthetic restorative materials. Eur J Oral Sci 2024; 132:e13016. [PMID: 39272220 DOI: 10.1111/eos.13016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2024] [Accepted: 08/17/2024] [Indexed: 09/15/2024]
Abstract
The study aimed to investigate the influence of H2O2-based and H2O2-free in-office bleaching on the surface and mechanical attributes of CAD/CAM composite blocks. CAD/CAM composite blocks from five different composite materials (CC1, CC2, CC3, CC4, and CC5) were randomly divided into two groups according to bleaching application (H2O2-based and H2O2-free). The surface topography, morphology, nanohardness, elastic modulus, flexural strength, and fracture toughness were measured. A paired and unpaired sample t-tests gauged the effect of pre- and post-bleaching on the substrates. The estimated mean differences (before-after bleaching) suggested an increase in surface roughness for two materials CC2 and CC4, and a significant decrease in nanohardness for material CC4 and in elastic modulus for materials CC2 and CC4 with H2O2-based bleaching, whereas H2O2-free bleaching resulted in changes compatible with no change in these properties. Flexural strength and fracture toughness showed no evidence of changes, irrespective of the bleaching gel used. Scanning electron microscopic analysis revealed erosive effects and micropore formation due to H2O2-based bleaching. H2O2-based bleaching deteriorates the surface of CAD/CAM composite materials while H2O2-free bleaching gel had an insignificant effect on both surface and bulk properties. The clinician should carefully evaluate the potential effects of H2O2-based bleaching on the surface properties of CAD/CAM composites.
Collapse
Affiliation(s)
- Majed M Alsarani
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Aftab Ahmed Khan
- Dental Health Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Leonel S J Bautista
- Dental and Oral Rehabilitation Department, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Hanan Alsunbul
- Restorative Dentistry Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
| | - Jukka P Matinlinna
- Division of Dentistry, School of Medical Sciences, The University of Manchester, Manchester, UK
| |
Collapse
|
4
|
Gonçalves F, Ayala-Perez MD, Reis FCDS, Miranda-Júnior WG, Boaro LCC. Exploring Zirconia Adhesion: Pre and Postsintering Physical Surface Treatment, Chemical Treatment, and Cement Interactions. BIOMED RESEARCH INTERNATIONAL 2024; 2024:5394652. [PMID: 39220997 PMCID: PMC11362578 DOI: 10.1155/2024/5394652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 07/31/2024] [Indexed: 09/04/2024]
Abstract
Background: Adhesion to zirconia remains a significant dental challenge. This study is aimed at assessing the bond strength of zirconia based on surface treatment with pre or postsintering sandblasting associated with different chemical treatments and resin cements. Methods: Zirconia blocks were divided into 12 experimental groups based on the surface treatment (presintering sandblasting or postsintering sandblasting/tribochemical abrasion treatment), chemical treatment (none, Single Bond Universal, or Signum Zirconia Bond), and choice of cement (Panavia F or RelyX™ U200). The bond strength was measured by shear tests using a universal testing machine. The fracture analysis was performed using stereomicroscopy. Data were analyzed using three-way ANOVA and Tukey's test (α = 5%). Results: Triple and double factor's interactions were not significant (p > 0.05). Regarding the surface treatment factor, the bond strength following postsintering sandblasting treatment associated with tribochemical abrasion (9.15 ± 3.62 MPa) was significantly higher than presintering sandblasting treatment (5.24 ± 3.53 MPa). Concerning the chemical treatment factor, bond strengths were ranked as follows: Signum Zirconia Bond > Single Bond Universal > no treatment. The bond strength of the resin cements did not differ among them. Most fractures (67%) were classified as adhesive, and 32% were categorized as mixed fractures. Conclusion: Surface treatment via postsintering sandblasting combined with tribochemical abrasion demonstrated superior efficacy than in presintering sandblasting. Additionally, chemical treatment with zirconia primer increased the bond strength of zirconia irrespective of the surface physical treatment.
Collapse
Affiliation(s)
- Flávia Gonçalves
- Faculdade de OdontologiaUniversidade Santo Amaro, Av. Prof. Eneas de Siqueira Neto, 340 04829-900, São Paulo, SP, Brazil
| | - Mirko Dennys Ayala-Perez
- Faculdade de OdontologiaUniversidade Santo Amaro, Av. Prof. Eneas de Siqueira Neto, 340 04829-900, São Paulo, SP, Brazil
| | | | - Walter Gomes Miranda-Júnior
- Departamento de Biomateriais e Biologia OralFaculdade de Odontologia da Universidade de São Paulo, Av. Prof. Lineu Prestes, 2222 05508-000, São Paulo, SP, Brazil
| | | |
Collapse
|
5
|
Hoffmann M, Schmeiser F, Donmez MB, Meinen J, Stawarczyk B. Surface Modification of Feldspathic Ceramic Used for Minimally Invasive Restorations: Effect of Airborne Particle Type on the Surface Properties and Biaxial Flexural Strength. MATERIALS (BASEL, SWITZERLAND) 2024; 17:3777. [PMID: 39124441 PMCID: PMC11312512 DOI: 10.3390/ma17153777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2024] [Revised: 07/23/2024] [Accepted: 07/29/2024] [Indexed: 08/12/2024]
Abstract
This study aimed to evaluate the effect of airborne particle abrasion with different particles on the surface free energy, roughness, and biaxial flexural strength of a feldspathic ceramic by comparing it with hydrofluoric acid etching, the standard surface treatment, and polishing. Square-shaped feldspathic ceramic specimens (12 mm × 12 mm × 1.2 mm) were divided into subgroups as airborne particles abraded with alumina (AO3a, AO3b, AO25, AO50a, AO50b, AO90, AO110a, AO110b, AO120a, and AO120b), silica (SO50a, SO50b, SO100, and SO100/200), or nutshell granule (NS100/200), hydrofluoric acid etched, and polished (n = 12). Surface free energy (n = 5), roughness (n = 5), biaxial flexural strength (n = 12), and Weibull moduli (n = 12) were investigated. Data were evaluated with 1-way ANOVA and Tukey HSD tests, and possible correlations were investigated with Pearson's correlation (α = 0.05). SO100/200 mostly had lower surface free energy (p ≤ 0.011), and polishing and etching led to higher surface free energy than AO3a, AO3b, and AO120a (p ≤ 0.031). Polished, SO100, and SO50b specimens mostly had lower roughness and AO125 had the highest roughness (p ≤ 0.029). SO100/200 mostly had lower biaxial flexural strength (p ≤ 0.041), and etched specimens had higher biaxial flexural strength than AO120a, AO120b, and SO50b (p ≤ 0.043). AO3b had the highest (33.56) and AO120b had the lowest (11.8) Weibull modulus. There was a weak positive correlation between the surface free energy and the biaxial flexural strength (r = 0.267, p = 0.011). A larger particle size mostly resulted in higher roughness, which was also affected by the particle shape. Most of the test groups had similar biaxial flexural strength to that of the hydrofluoric acid-etched group. Therefore, for tested feldspathic ceramic, airborne particle abrasion with tested parameters may be a suitable alternative without causing any further damage.
Collapse
Affiliation(s)
- Moritz Hoffmann
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (F.S.); (J.M.); (B.S.)
| | - Felix Schmeiser
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (F.S.); (J.M.); (B.S.)
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Biruni University, 34015 Istanbul, Turkey
| | - John Meinen
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (F.S.); (J.M.); (B.S.)
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (F.S.); (J.M.); (B.S.)
| |
Collapse
|
6
|
Zhu H, Jiang J, Wang Y, Wang S, He Y, He F. Additive manufacturing of dental ceramics in prosthodontics: The status quo and the future. J Prosthodont Res 2024; 68:380-399. [PMID: 38346729 DOI: 10.2186/jpr.jpr_d_23_00119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/09/2024]
Abstract
PURPOSE This review aims to summarize the available technologies, material categories, and prosthodontic applications of additive manufacturing (AM) dental ceramics, evaluate the achievable accuracy and mechanical properties in comparison with current mainstream computer-aided design/computer-aided manufacturing (CAD/CAM) subtractive manufacturing (SM) methods, and discuss future prospects and directions. STUDY SELECTION This paper is based on the latest reviews, state-of-the-art research, and existing ISO standards on AM technologies and prosthodontic applications of dental ceramics. PubMed, Web of Science, and ScienceDirect were amongst the sources searched for narrative reviews. RESULTS Relatively few AM technologies are available and their applications are limited to crowns and fixed partial dentures. Although the accuracy and strength of AM dental ceramics are comparable to those of SM, they have the limitations of relatively inferior curved surface accuracy and low strength reliability. Furthermore, functionally graded additive manufacturing (FGAM), a potential direction for AM, enables the realization of biomimetic structures, such as natural teeth; however, specific studies are currently lacking. CONCLUSIONS AM dental ceramics are not sufficiently developed for large-scale clinical applications. However, with additional research, it may be possible for AM to replace SM as the mainstream manufacturing technology for ceramic restorations.
Collapse
Affiliation(s)
- Han Zhu
- Department of Periodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Jimin Jiang
- Department of Periodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Yujie Wang
- Department of Periodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Sijie Wang
- Department of Periodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| | - Yong He
- State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, PR China
| | - Fuming He
- Department of Periodontics, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China
| |
Collapse
|
7
|
Saini RS, Alshadidi AAF, Gurumurthy V, Okshah A, Vaddamanu SK, Binduhayyim RIH, Chaturvedi S, Bavabeedu SS, Heboyan A. Quantum mechanical analysis of yttrium-stabilized zirconia and alumina: implications for mechanical performance of esthetic crowns. Eur J Med Res 2024; 29:254. [PMID: 38659074 PMCID: PMC11044456 DOI: 10.1186/s40001-024-01851-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Accepted: 04/18/2024] [Indexed: 04/26/2024] Open
Abstract
BACKGROUND Yttrium-stabilized zirconia (YSZ) and alumina are the most commonly used dental esthetic crown materials. This study aimed to provide detailed information on the comparison between yttrium-stabilized zirconia (YSZ) and alumina, the two materials most often used for esthetic crowns in dentistry. METHODOLOGY The ground-state energy of the materials was calculated using the Cambridge Serial Total Energy Package (CASTEP) code, which employs a first-principles method based on density functional theory (DFT). The electronic exchange-correlation energy was evaluated using the generalized gradient approximation (GGA) within the Perdew (Burke) Ernzerhof scheme. RESULTS Optimization of the geometries and investigation of the optical properties, dynamic stability, band structures, refractive indices, and mechanical properties of these materials contribute to a holistic understanding of these materials. Geometric optimization of YSZ provides important insights into its dynamic stability based on observations of its crystal structure and polyhedral geometry, which show stable configurations. Alumina exhibits a distinctive charge, kinetic, and potential (CKP) geometry, which contributes to its interesting structural framework and molecular-level stability. The optical properties of alumina were evaluated using pseudo-atomic computations, demonstrating its responsiveness to external stimuli. The refractive indices, reflectance, and dielectric functions indicate that the transmission of light by alumina depends on numerous factors that are essential for the optical performance of alumina as a material for esthetic crowns. The band structures of both the materials were explored, and the band gap of alumina was determined to be 5.853 eV. In addition, the band structure describes electronic transitions that influence the conductivity and optical properties of a material. The stability of alumina can be deduced from its bandgap, an essential property that determines its use as a dental material. Refractive indices are vital optical properties of esthetic crown materials. Therefore, the ability to understand their refractive-index graphs explains their transparency and color distortion through how the material responds to light..The regulated absorption characteristics exhibited by YSZ render it a highly attractive option for the development of esthetic crowns, as it guarantees minimal color distortion. CONCLUSION The acceptability of materials for esthetic crowns is strongly determined by mechanical properties such as elastic stiffness constants, Young's modulus, and shear modulus. YSZ is a highly durable material for dental applications, owing to its superior mechanical strength.
Collapse
Affiliation(s)
- Ravinder S Saini
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | | | - Abdulmajeed Okshah
- Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
| | | | | | - Saurabh Chaturvedi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Shashit Shetty Bavabeedu
- Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Artak Heboyan
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 600 077, India.
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Str. Koryun 2, 0025, Yerevan, Armenia.
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, North Karegar St, Tehran, Iran.
| |
Collapse
|
8
|
Branco AC, Santos T, Bessa LJ, Barahona I, Polido M, Colaço R, Serro AP, Figueiredo-Pina CG. Optimized 3D printed zirconia-reinforced leucite with antibacterial coating for dental applications. Dent Mater 2024; 40:629-642. [PMID: 38369404 DOI: 10.1016/j.dental.2024.02.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 01/17/2024] [Accepted: 02/12/2024] [Indexed: 02/20/2024]
Abstract
OBJECTIVES This study aims to produce by robocasting leucite/zirconia pieces with suitable mechanical and tribological performance, convenient aesthetics, and antibacterial properties to be used in dental crown replacement. METHODS Leucite pastes reinforced with 12.5%, 25%, and 37.5% wt. ZrO2 nanoparticles were prepared and used to print samples that after sintering were characterized in terms of density, shrinkage, morphology, porosity, mechanical and tribological properties and translucency. A coating of silver diamine fluoride (SDF) and potassium iodide (KI) was applied over the most promising material. The material's antibacterial activity and cytotoxicity were assessed. RESULTS It was found that the increase of ZrO2 reinforcement up to 25% enhanced both microhardness and fracture toughness of the sintered composite. However, for a superior content of ZrO2, the increase of the porosity negatively affected the mechanical behaviour of the composite. Moreover, the composite with 25% ZrO2 exhibited neglectable wear in chewing simulator tests and induced the lowest wear on the antagonist dental cusps. Although this composite exhibited lower translucency than human teeth, it was three times higher than the ZrO2 glazed material. Coating this composite material with SDF+KI conferred antibacterial properties without inducing cytotoxicity. SIGNIFICANCE Robocasting of leucite reinforced with 25% ZrO2 led to best results. The obtained material revealed superior optical properties and tribomechanical behaviour compared to glazed ZrO2 (that is a common option in dental practice). Moreover, the application of SDF+KI coating impaired S. aureus proliferation, which anticipates its potential benefit for preventing pathogenic bacterial complications associated with prosthetic crown placement.
Collapse
Affiliation(s)
- A C Branco
- CQE, Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CDP2T, Centro de Desenvolvimento de Produto e Transferência de Tecnologia, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | | | - L J Bessa
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - I Barahona
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - M Polido
- CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal
| | - R Colaço
- IDMEC e Departamento de Engenharia Mecânica, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| | - A P Serro
- CQE, Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Engenharia Química, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal.
| | - C G Figueiredo-Pina
- CDP2T, Centro de Desenvolvimento de Produto e Transferência de Tecnologia, Escola Superior de Tecnologia de Setúbal, Instituto Politécnico de Setúbal, Setúbal, Portugal; CiiEM, Egas Moniz Center for Interdisciplinary Research, Egas Moniz School of Health & Science, Almada, Portugal; CeFEMA, Centro de Física e Engenharia de Materiais Avançados, Instituto Superior Técnico, Universidade de Lisboa, Lisboa, Portugal
| |
Collapse
|
9
|
Alshahrani AM, Lim CH, Wolff MS, Janal MN, Zhang Y. Current speed sintering and high-speed sintering protocols compromise the translucency but not strength of yttria-stabilized zirconia. Dent Mater 2024; 40:664-673. [PMID: 38378371 PMCID: PMC11015968 DOI: 10.1016/j.dental.2024.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 01/05/2024] [Accepted: 02/12/2024] [Indexed: 02/22/2024]
Abstract
OBJECTIVES To investigate the impacts of speed and high-speed sintering on the densification, microstructure, phase composition, translucency, and flexural strength of yttria-stabilized zirconia (YSZ). METHODS A total of 162 disc-shaped specimens (n = 18) were cold-isostatically pressed from 3YSZ (Zpex), 4YSZ (Zpex 4), and 5YSZ (Zpex Smile) powders (Tosoh Corporation) and sintered according to the following protocols: conventional (control, ∼12 h), speed (∼28 min for 3YSZ; ∼60 min for 4YSZ and 5YSZ), and high-speed (∼18 min) sintering. Dimensions of zirconia specimens after sintering and polishing (1-μm diamond grit finish) were Ø13.75 × 1 mm. Density, microstructure, phase content, translucency parameter, and biaxial flexural strength were evaluated using Archimedes', SEM, XRD, spectrophotometric, and piston-on-3-ball methods, respectively. Data were analyzed with either one-way ANOVA and Tukey's test or Kruskal-Wallis with Dunn's test (α = 0.05). RESULTS For all YSZ compositions, conventional sintering yielded the highest density followed by speed then high-speed sintering. All sintering protocols resulted in similar strength values; however, speed and high-speed sintering protocols afforded significantly lower translucency relative to conventional sintering. XRD analysis revealed similar spectra for YSZs sintered by various protocols. The speed sintered specimens had the smallest grain size whereas the high-speed sintered 5YSZ possessed the largest grain size among all groups. SEM examination of all YSZ compositions revealed that the average pore size was an order of magnitude smaller than the average grain size. SIGNIFICANCE Speed and high-speed sintering of YSZs yield similar strength but diminished density and translucency relative to their conventionally sintered counterparts.
Collapse
Affiliation(s)
- Abdulaziz M Alshahrani
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Restorative Dental Sciences, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Chek Hai Lim
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Mark S Wolff
- Morton Amsterdam Dean, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Malvin N Janal
- Department of Epidemiology & Health Promotion, New York University College of Dentistry, New York, NY 10010, USA
| | - Yu Zhang
- Laboratories for Microstructure Physics & Mechanics of Materials, Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
10
|
Lopez D, Ziada H, Abubakr NH. Influence of thermal aging on the marginal integrity of computer aided design/computer aided manufacturing fabricated crowns. J Dent Sci 2024; 19:971-977. [PMID: 38618116 PMCID: PMC11010792 DOI: 10.1016/j.jds.2023.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 07/07/2023] [Indexed: 04/16/2024] Open
Abstract
Background/purpose The adaptation and marginal integrity of computer-aided designed and computer-aided manufactured (CAD/CAM) crowns after exposure to thermal aging need to be investigated. The present in-vitro study was designed to investigate the marginal integrity of CAD/CAM fabricated crowns cemented on extracted teeth after thermocycling aging. Materials and methods Twenty-six newly extracted human premolars were prepared for full-coverage CAD/CAM crowns and were divided into two groups (leucite-reinforced glass-ceramics and lithium disilicate glass-ceramics). Both crowns' groups were cemented using dual curing resin cement. All specimen margins were measured for marginal integrity using an imaging system 24 h post cementation; then after 1, 3, and 5 estimated clinical years (10,000, 30,000, and 50,000 thermocycles). Two-way ANOVA analysis were used to determine whether the mean value difference is significantly different (ɑ = 0.05). Results The average margin gaps recorded for leucite-reinforced glass-ceramic crowns were: 82.61 μm initial, and 91.02 μm after 5 estimated clinical year). For the lithium disilicate glass-ceramic crowns, the average margin gaps recorded were: 100.01 μm initial, and 120.21 μm after 5 estimated clinical year. During all measuring intervals, the leucite-reinforced glass-ceramic crown group had a lower marginal discrepancy. No statistically significant difference between the two groups was recorded. Conclusion After being subjected to thermocycling, both CAD/CAM ceramic crowns, exhibited an increase in their marginal discrepancy; the difference was within the accepted clinical range.
Collapse
Affiliation(s)
- Diana Lopez
- Department of Restorative Dentistry, Harvard School of Dental Medicine, Boston, MA, USA
| | - Hassan Ziada
- Clinical Sciences Department, School of Dental Medicine, University of Nevada, Las Vegas, NV, USA
| | - Neamat Hassan Abubakr
- Biomedical Sciences Department, School of Dental Medicine, University of Nevada, Las Vegas, NV, USA
| |
Collapse
|
11
|
Albani R, Habib SR, AlQahtani A, AlHelal AA, Alrabiah M, Anwar S. The Surface Roughness of Contemporary Indirect CAD/CAM Restorative Materials That Are Glazed and Chair-Side-Finished/Polished. MATERIALS (BASEL, SWITZERLAND) 2024; 17:997. [PMID: 38473470 DOI: 10.3390/ma17050997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 02/11/2024] [Accepted: 02/14/2024] [Indexed: 03/14/2024]
Abstract
The surface roughness (Ra) of indirect computer-aided design/computer-aided manufacturing (CAD/CAM)-fabricated dental restorations is crucial for their long-term durability. This study intended to evaluate the Ra of five different types of contemporary indirect CAD/CAM restorative materials with varying compositions that were glazed and finished/polished. A total of 75 specimens, disc-shaped (10 mm × 2 mm), were obtained from five materials (n = 15) (Tetric CAD, IPS e.max CAD, IPS e.max ZirCAD, CELTRA Duo, and Vita Enamic) and fabricated by CAD/CAM. One of the two surfaces for each specimen was subjected to glazing, while the other surface was subjected to finishing/polishing. The Ra of the two surfaces in micrometers (μm) was evaluated using a Profilometer, while the surface topography was examined using a scanning electron microscope. Using SPSS, the Kruskal-Wallis, post hoc Conover, and Mann-Whitney tests were used to statistically evaluate the data. A comparison of the Ra for the finished/polished surfaces of the five test materials showed significant differences (p < 0.0001). Among the finished/polished surfaces, the mean rank values of Vita Enamic were significantly higher than the other four test materials (p < 0.0001). A comparison of the Ra of glazed surfaces among the five study materials revealed significant differences (p < 0.0001). The Ra for the IPS e.max ZirCAD material was significantly higher than the rest of the four materials (p < 0.001). A comparison of the Ra for two types of surface conditioning within each of the five test materials showed a significant difference (p < 0.05). Only for IPS e.max ZirCAD was the Ra of the glazed surface significantly higher than the finished/polished surface (p < 0.0001). Significant variations in the surface roughness (Ra) were exhibited between the finished/polished and glazed surfaces of the five test materials. Hybrid ceramics showed the highest Ra values for the finished/polished surfaces, and zirconia exhibited the highest Ra values among the glazed surfaces among the tested materials. The Ra values of either finished/polished or glazed surfaces of the test materials were within the clinically acceptable range (0.2-0.5 μm), except for the glazed surface of the zirconia ceramics (0.84 μm).
Collapse
Affiliation(s)
- Ragad Albani
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Syed Rashid Habib
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Abdulaziz AlQahtani
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Abdulaziz A AlHelal
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Mohammed Alrabiah
- Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh 11545, Saudi Arabia
| | - Saqib Anwar
- Industrial Engineering Department, College of Engineering, King Saud University, Riyadh 11545, Saudi Arabia
| |
Collapse
|
12
|
Robaian A, Alotaibi NM, Allaboon AK, AlTuwaijri DS, Aljarallah AF, Alshehri RS, Alabsi AA, Mirza MB, Al Moaleem MM. Factors Influencing Dentists' Choice of Restorative Materials for Single-Tooth Crowns: A Survey Among Saudi Practitioners. Med Sci Monit 2024; 30:e942723. [PMID: 38310349 PMCID: PMC10851618 DOI: 10.12659/msm.942723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 12/06/2023] [Indexed: 02/05/2024] Open
Abstract
BACKGROUND Material selection is crucial in restorative dentistry, influenced by aesthetics, material properties, and tooth location. This understanding is key for advancing dental practices and patient outcomes. The present study aimed to assess dentists' preferences for restorative materials in single-tooth crowns (SC) and how abutment tooth location and preparation margins influence these choices. MATERIAL AND METHODS A web-based pre-validated questionnaire survey was conducted among 811 actively practicing dentists in Saudi Arabia. RESULTS In posterior teeth, we found that ceramic was the most preferred material for SC regardless of the abutment tooth location and location of margins, followed by porcelain fused to metal (PFMs). In anterior teeth, ceramics were preferred, followed by CAD/CAM-based resin SC. Among the choice of ceramics in teeth for both supra-gingival margins, monolith zirconia was the most-preferred material for SC fabrication in posterior teeth, followed by zirconia-reinforced lithium silicate ceramic. Similarly, for sub-gingival margins, monolith zirconia crowns were the most popular option in posterior teeth among the respondents, with the highest in the mandibular molar region. In the anterior region, layered zirconia was the least preferred, and lithium disilicate ceramics was the most-favored option. A statistically significant difference existed between supra- and subgingival preparation for teeth 11 (P=0.01), 16 (P=0.03), and 34 (P=0.02). CONCLUSIONS Ceramic was the material of choice among Saudi dentists for replacement of SC, irrespective of the location and preparation margin. Monolith zirconia was usually selected for posterior teeth and lithium disilicate ceramics was the top choice in anterior teeth.
Collapse
Affiliation(s)
- Ali Robaian
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al Kharj, Saudi Arabia
| | | | | | - Danah Saleh AlTuwaijri
- Resident, Saudi Board in Restorative Dentistry, Second Health Cluster, Riyadh, Saudi Arabia
| | - Abdullah Fahad Aljarallah
- Resident, Saudi Board in Family Dentistry, College of Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia
| | - Rola Salman Alshehri
- Dental Student, College of Dentistry, Princess Nourah bint Abdul Rahman University, Riyadh, Saudi Arabia
| | | | - Mubashir Baig Mirza
- Conservative Dental Science Department, College of Dentistry, Prince Sattam bin Abdulaziz University, Al Kharj, Saudi Arabia
| | - Mohammed M. Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan, Saudi Arabia
| |
Collapse
|
13
|
Hrițuc A, Ermolai V, Mihalache AM, Andrușcă L, Dodun O, Nagîț G, Boca MA, Slătineanu L. Compressive Behavior of Some Balls Manufactured by 3D Printing from Ceramic-Polymer Composite Materials. MICROMACHINES 2024; 15:150. [PMID: 38276849 PMCID: PMC10821401 DOI: 10.3390/mi15010150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 12/24/2023] [Accepted: 01/16/2024] [Indexed: 01/27/2024]
Abstract
It is known that ceramic-polymer composite materials can be used to manufacture spherical bodies in the category of balls. Since balls are frequently subjected to compression loads, the paper presents some research results on the compression behavior of balls made of ceramic composite materials with a polymer matrix. The mathematical model of the pressure variation inside the balls highlights the existence of maximum values in the areas of contact with other parts. Experimental research was carried out on balls with a diameter of 20 mm, manufactured by 3D printing from four ceramic-polymer composite materials with a polymer matrix: pottery clay, terracotta, concrete, and granite. The same ceramic-polymer composite material was used, but different dyes were added to it. A gravimetric analysis revealed similar behavior of the four materials upon controlled heating. Through the mathematical processing of the experimental results obtained by compression tests, empirical mathematical models of the power-type function type were determined. These models highlight the influence exerted by different factors on the force at which the initiation of cracks in the ball materials occurs. The decisive influence of the infill factor on the size of the force at which the cracking of the balls begins was found.
Collapse
Affiliation(s)
- Adelina Hrițuc
- Department of Machine Manufacturing Technology, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania; (V.E.); (A.M.M.); (O.D.); (G.N.); (M.A.B.); (L.S.)
| | - Vasile Ermolai
- Department of Machine Manufacturing Technology, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania; (V.E.); (A.M.M.); (O.D.); (G.N.); (M.A.B.); (L.S.)
| | - Andrei Marius Mihalache
- Department of Machine Manufacturing Technology, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania; (V.E.); (A.M.M.); (O.D.); (G.N.); (M.A.B.); (L.S.)
| | - Liviu Andrușcă
- Department of Mechanical Engineering, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania;
| | - Oana Dodun
- Department of Machine Manufacturing Technology, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania; (V.E.); (A.M.M.); (O.D.); (G.N.); (M.A.B.); (L.S.)
| | - Gheorghe Nagîț
- Department of Machine Manufacturing Technology, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania; (V.E.); (A.M.M.); (O.D.); (G.N.); (M.A.B.); (L.S.)
| | - Marius Andrei Boca
- Department of Machine Manufacturing Technology, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania; (V.E.); (A.M.M.); (O.D.); (G.N.); (M.A.B.); (L.S.)
| | - Laurențiu Slătineanu
- Department of Machine Manufacturing Technology, “Gheorghe Asachi” Technical University of Iași, 700050 Iași, Romania; (V.E.); (A.M.M.); (O.D.); (G.N.); (M.A.B.); (L.S.)
| |
Collapse
|
14
|
Frasnelli GD, Leoni GB, Cassani R, Faria ACL, Gomes EA, Moris ICM. Effect of different ceramic systems on antagonist dental structure by microtomographic analysis. Dent Mater 2024; 40:118-123. [PMID: 37940499 DOI: 10.1016/j.dental.2023.10.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 10/19/2023] [Accepted: 10/25/2023] [Indexed: 11/10/2023]
Abstract
OBJECTIVES This study aims to identify the two-dimensional and three-dimensional analyses and evaluate the loss of tooth structure in the tooth's different constituent elements and the ceramic antagonist's surface. METHODS In this study, three groups (n = 10) represented by different ceramic systems (lithium disilicate [GDis], lithium silicate reinforced with zirconia [GSil], and monolithic zirconia [GZir]) were evaluated. Each group obtained ten ceramic blocks and submitted them to the sintering/crystallization process. To carry out the wear test, healthy mandibular premolars were used as the specimens and the ceramic blocks as antagonists. The premolars were submitted to two-dimensional and three-dimensional analyses using a computerized microtomography (µTC) before and after the wear test. The wear test was performed with 30 N and 300,000 cycles load, with occlusion, laterality, and disocclusion movements. RESULTS The statistical analysis comparing the loss of two-dimensional tooth structure showed a statistically significant difference among all groups (p < 0.05). Statistical analysis comparing the percentage of loss of three-dimensional tooth structure showed a statistically significant difference between groups GDis and GSil and between groups GDis and GZir. However, when comparing GSil with GZir, no statistically significant difference was found. The qualitative analysis of the teeth showed that GDis showed considerable enamel loss and dentin exposure, GSil showed enamel wear with flattening the cusp without dentin exposure, and GZir showed minimal enamel wear without dentin exposure. In the qualitative analysis of ceramic antagonists, more significant wear of the ceramic material for GDis was observed, followed by the GSil and GZir groups, respectively. SIGNIFICANCE The use of the lithium disilicate should be cautious, restricting it to areas with lower masticatory forces. Areas of higher masticatory forces showed a large amount of antagonist wear, with dentin involvement. This can lead to dentinal hypersensitivity, risk of compromising patients' occlusion, by harming group disocclusion guides, causing pain and temporomandibular disorders.
Collapse
Affiliation(s)
| | | | - Raquel Cassani
- School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, SP, Brazil
| | | | - Erica Alves Gomes
- School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, SP, Brazil
| | - Izabela C M Moris
- School of Dentistry, University of Ribeirão Preto (UNAERP), Ribeirão Preto, SP, Brazil.
| |
Collapse
|
15
|
Mosaddad SA, Abduo J, Zakizade M, Tebyaniyan H, Hussain A. The Effect of Various Lasers on the Bond Strength Between Orthodontic Brackets and Dental Ceramics: A Systematic Review and Meta-Analysis. Photobiomodul Photomed Laser Surg 2024; 42:20-48. [PMID: 37862260 DOI: 10.1089/photob.2023.0098] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2023] Open
Abstract
Background/objective: This systematic review and meta-analysis aimed to assess how laser conditioning affected brackets bonded to dental ceramics' shear bond strength (SBS). Materials and methods: The study was conducted by searching Pubmed/Medline, Scopus, Embase, Web of Science, the Cochrane Library, and Google Scholar up to September 14, 2022. In addition, the reference lists of the relevant articles were checked manually. Articles that compared SBS of laser-treated feldspathic, lithium disilicate, or zirconia surfaces with other standard techniques for bonding metal or ceramic orthodontic brackets were considered. Using a random-effects model, data pooling was carried out as the weighted mean difference (WMD). Results: This study initially contained 1717 reports, and following review, 32 articles were deemed suitable for our meta-analysis. The pooling results showed that the treatments with lasers such as "Er:YAG" [WMD = -1.12 MPa; 95% confidence interval (CI): -1.93 to -0.31], "Er:YAG + Silane" (WMD = -3.08 MPa; 95% CI: -4.77 to -1.40), and "Nd: YAG + Silane" (WMD = -2.58 MPa; 95% CI: -3.76 to -1.40) had statistically significant lower adhesion values compared with controls. Contrarily, "Ti:Sapphire femtosecond" demonstrated significantly higher bonding values (WMD = 0.94 MPa; 95% CI: 0.29-1.60). In contrast, other interventions obtained no statistically significant difference in SBS. Conclusions: Most of the laser groups showed results comparable with those of conventional approaches. Although more research is necessary for definitive conclusions, laser treatment may be an effective option for treating the surfaces of ceramic materials.
Collapse
Affiliation(s)
- Seyed Ali Mosaddad
- Student Research Committee, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Jaafar Abduo
- Department of Prosthodontics, Melbourne Dental School, Melbourne University, Melbourne, Victoria, Australia
| | - Mehrnaz Zakizade
- Department of Orthodontics, School of Dentistry, Shahr-e-Kord University of Medical Sciences, Shahr-e-Kord, Iran
| | - Hamid Tebyaniyan
- Department of Science and Research, Islimic Azade University, Tehran, Iran
| | - Ahmed Hussain
- School of Dentistry, Edmonton Clinic Health Academy, University of Alberta, Edmonton, Canada
| |
Collapse
|
16
|
Soni P, Shrivastava P, Rai SK. Development of reduced volume endosseous cuspid tooth implant using topology optimization by SIMP technique for improved osseointegration. Comput Methods Biomech Biomed Engin 2023:1-15. [PMID: 37950447 DOI: 10.1080/10255842.2023.2279939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 10/01/2023] [Indexed: 11/12/2023]
Abstract
The article aims to design and develop a topology-optimized endosseous cuspid tooth implant of the maxilla region. The manuscript presents a numerical analysis of the resulting von Mises stresses and effective strain resulting in the topology-optimized implant with occlusal loading of 110 N. Solid Isotropic Material with Penalization (SIMP) method is employed for topology optimization and four different models, namely model-1, model-2, model-3, and model-4, are developed based on volume reduction rates of 8%, 16%, 24%, and 32%, respectively. FEA results highlight that the maximum stress and strain in the screw increases with volume reduction rates. The comparative analyses of the resulting stresses in the compact and cancellous bone along with the strain in the screw led to the conclusion that model-1, model-2, and model-3 resulted in moderate stresses on compact and cancellous bone compared to the original model of the implant. However, the screw and bones are subjected to maximum stress and strain in the model-4. The study concludes that model-2, with 16% reduced volume and 14.2% reduced mass as compared to the original implant, may be considered as the optimized design of the model. The resulting model offers a significant reduction in the weight and volume with a minor increase in effective stress and strain without negatively impacting the functionality and bio-mechanical performance of the implant. The optimized dental implant prototype is also fabricated as a proof of concept by the Fused Deposition Modelling process.
Collapse
Affiliation(s)
- Priyanshu Soni
- School of Biomedical Engineering, Indian Institute of Technology BHU, Varanasi, India
| | - Parnika Shrivastava
- Department of Mechanical Engineering, National Institute of Technology, Jalandhar, India
| | - Sanjay Kumar Rai
- School of Biomedical Engineering, Indian Institute of Technology BHU, Varanasi, India
| |
Collapse
|
17
|
Flexural Strength Properties of Five Different Monolithic Computer-Aided Design/Computer-Aided Manufacturing Ceramic Materials: An In Vitro Study. Cureus 2023; 15:e36958. [PMID: 37009356 PMCID: PMC10064933 DOI: 10.7759/cureus.36958] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/31/2023] [Indexed: 04/03/2023] Open
Abstract
Objective The purpose of this in vitro study is to compare the flexural strength and Weibull modulus of 5 different monolithic computer-aided design/computer-aided manufacturing (CAD/CAM) ceramics. Methods A total of 50 specimens were fabricated, 10 from each of the following materials: lithium disilicate-based ceramic (IPS e.max CAD), zirconia -reinforced lithium-silicate ceramic (Vita Suprinity), leucite-based glass ceramic (IPS Empress CAD), and two zirconia-based ceramics (Zenostar and CopraSmile). The specimens were 4 mm wide, 2 mm thick, and 16 mm long. Flexural strength test was executed using a universal testing machine (Model 5980, Instron Industrial Products, Norwood, MA, USA). The two-parameter Weibull distribution function was used to analyze the variability of flexural strength values. Statistical analysis was performed on SPSS Version 23 (IBM Corp., Armonk, NY, USA) using one-way analysis of variance (ANOVA) and post-hoc Tukey’s test. Results Suprinity had the highest Weibull modulus value, while Empress CAD displayed the lowest value. One-way ANOVA showed significant difference in the flexural strength between the different materials tested (p<0.05). Post-hoc analysis revealed significant differences among all the test groups in terms of flexural strength. Zenostar presented the highest mean flexural strength value (1033.90 MPa), while Empress CAD had the lowest value. Conclusion High-translucency zirconia had superior flexural properties than translucent zirconia, lithium disilicate ceramics, zirconia-reinforced lithium silicate ceramics, and leucite-based glass ceramics.
Collapse
|
18
|
Vaiani L, Boccaccio A, Uva AE, Palumbo G, Piccininni A, Guglielmi P, Cantore S, Santacroce L, Charitos IA, Ballini A. Ceramic Materials for Biomedical Applications: An Overview on Properties and Fabrication Processes. J Funct Biomater 2023; 14:146. [PMID: 36976070 PMCID: PMC10052110 DOI: 10.3390/jfb14030146] [Citation(s) in RCA: 13] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Revised: 02/14/2023] [Accepted: 03/02/2023] [Indexed: 03/08/2023] Open
Abstract
A growing interest in creating advanced biomaterials with specific physical and chemical properties is currently being observed. These high-standard materials must be capable to integrate into biological environments such as the oral cavity or other anatomical regions in the human body. Given these requirements, ceramic biomaterials offer a feasible solution in terms of mechanical strength, biological functionality, and biocompatibility. In this review, the fundamental physical, chemical, and mechanical properties of the main ceramic biomaterials and ceramic nanocomposites are drawn, along with some primary related applications in biomedical fields, such as orthopedics, dentistry, and regenerative medicine. Furthermore, an in-depth focus on bone-tissue engineering and biomimetic ceramic scaffold design and fabrication is presented.
Collapse
Affiliation(s)
- Lorenzo Vaiani
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Antonio Boccaccio
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Antonio Emmanuele Uva
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Gianfranco Palumbo
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Antonio Piccininni
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Pasquale Guglielmi
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
| | - Stefania Cantore
- Independent Researcher, Sorriso & Benessere-Ricerca e Clinica, 70129 Bari, Italy
| | - Luigi Santacroce
- Microbiology and Virology Unit, Department of Interdisciplinary Medicine, University of Bari “Aldo Moro”, 70126 Bari, Italy
| | - Ioannis Alexandros Charitos
- Emergency/Urgency Department, National Poisoning Center, Riuniti University Hospital of Foggia, 71122 Foggia, Italy
| | - Andrea Ballini
- Department of Mechanics, Mathematics and Management, Polytechnic University of Bari, Via Orabona 4, 70125 Bari, Italy
- Department of Precision Medicine, University of Campania “Luigi Vanvitelli”, 80138 Naples, Italy
| |
Collapse
|
19
|
Denis C, Robberecht L, Delattre J, Deveaux E, Hornez JC, Dehurtevent M. Effect of dimensional variations on the manufacturing process and the 3D shrinkage ratio of stereolithographic dental alumina ceramics. Dent Mater J 2023; 42:79-85. [PMID: 36351601 DOI: 10.4012/dmj.2022-102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The purpose of the present study was to evaluate the influence of height and length variations of alumina ceramics manufactured by stereolithography on deformations caused by the manufacturing process and on the 3D shrinkage ratio to control the final dimensions and improve the adaptation of stereolithographic ceramic dental prostheses. Two different U-shaped models were designed with variable heights or lengths. The specimens were manufactured by stereolithography and were scanned using a microtomographic device before and after the heat treatment. Dimensional variations were measured using inspection software. The number and surface of layers of alumina ceramic influenced the reliability of the stereolithography manufacturing but did not influence the 3D shrinkage ratio. The larger the layer surface, the larger the deformation of the ceramic. Dental ceramics manufactured by stereolithography with smallest layer surface are the most reliable. This helps in the selection of the build orientation.
Collapse
Affiliation(s)
- Corentin Denis
- Department of Prosthodontics, Faculty of Dental Surgery, University of Lille.,INSERM U1008 - Controlled Drug Delivery Systems and Biomaterials, School of Medicine, University of Lille
| | - Lieven Robberecht
- INSERM U1008 - Controlled Drug Delivery Systems and Biomaterials, School of Medicine, University of Lille.,Department of Restorative Dentistry, Faculty of Dental Surgery, University of Lille
| | - Jérôme Delattre
- ULR 4490, Marrow Adiposity and Bone Laboratory, University of Lille
| | - Etienne Deveaux
- INSERM U1008 - Controlled Drug Delivery Systems and Biomaterials, School of Medicine, University of Lille.,Department of Restorative Dentistry, Faculty of Dental Surgery, University of Lille
| | - Jean-Christophe Hornez
- Laboratory of Ceramic Materials and Associated Processes, Université Polytechnique des Hauts de France
| | - Marion Dehurtevent
- Department of Prosthodontics, Faculty of Dental Surgery, University of Lille.,INSERM U1008 - Controlled Drug Delivery Systems and Biomaterials, School of Medicine, University of Lille
| |
Collapse
|
20
|
Ellakany P, Madi M, Aly NM, Alshehri T, Alameer ST, Al-Harbi FA. Influences of Different CAD/CAM Ceramic Compositions and Thicknesses on the Mechanical Properties of Ceramic Restorations: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2023; 16:ma16020646. [PMID: 36676383 PMCID: PMC9865408 DOI: 10.3390/ma16020646] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 12/24/2022] [Accepted: 12/26/2022] [Indexed: 05/14/2023]
Abstract
The aim of this study was to assess the influences of different CAD/CAM ceramic compositions and thicknesses on the surface roughness and hardness of ceramic restorations. Four different ceramics were used in the current study: lithium disilicate (LD), leucite reinforced (LE), advanced lithium disilicate (ALD), and zirconia-reinforced lithium silicate (ZLS). Each group included 30 specimens subdivided into three different ceramic thicknesses (0.5, 1 and 1.5 mm thicknesses). The microhardness was measured for all the specimens using a microhardness testing machine, while the surface roughness was measured using a non-contact optical profilometer at three intervals (before toothbrushing and after toothbrushing, with and without toothpaste). Three-way and two-way ANOVA were used to determine the factors influencing the surface roughness and microhardness. There was a significant difference in the surface roughness between the studied groups for all the thicknesses. The findings showed that ALD had the lowest surface roughness, while ZLS showed the highest surface roughness. Moreover, ALD, followed by ZLS, had the highest hardness, while LD and LE had the lowest hardness values. Regarding the thicknesses, both the 0.5 and 1 mm ceramic thicknesses showed a significantly lower surface roughness than the 1.5 mm thickness, while the 1.5 mm thickness showed a significantly higher microhardness than the 0.5 mm thickness. The surface roughness and hardness were significantly affected by the ceramic composition and type of filler. It is recommended to use 1.5 mm-thick ceramic materials for the fabrication of definitive full-coverage ceramic restorations, while veneers require 0.5 mm-thick materials. ALD is a promising CAD/CAM material that can be used for the fabrication of restorations with a proper strength in both anterior and posterior regions.
Collapse
Affiliation(s)
- Passent Ellakany
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
- Correspondence: ; Tel.: +966-547812107
| | - Marwa Madi
- Department of Preventive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Nourhan M. Aly
- Department of Pediatric Dentistry and Dental Public Health, Faculty of Dentistry, Alexandria University, Alexandria 21527, Egypt
| | - Turki Alshehri
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Shahad T. Alameer
- College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| | - Fahad A. Al-Harbi
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 32210, Saudi Arabia
| |
Collapse
|