1
|
Yuan H, Li Y, Yang J, Li H, Yang Q, Guo C, Zhu S, Shu X. State of the Art of Non-Invasive Electrode Materials for Brain-Computer Interface. MICROMACHINES 2021; 12:1521. [PMID: 34945371 PMCID: PMC8705666 DOI: 10.3390/mi12121521] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/01/2021] [Accepted: 12/02/2021] [Indexed: 02/02/2023]
Abstract
The brain-computer interface (BCI) has emerged in recent years and has attracted great attention. As an indispensable part of the BCI signal acquisition system, brain electrodes have a great influence on the quality of the signal, which determines the final effect. Due to the special usage scenario of brain electrodes, some specific properties are required for them. In this study, we review the development of three major types of EEG electrodes from the perspective of material selection and structural design, including dry electrodes, wet electrodes, and semi-dry electrodes. Additionally, we provide a reference for the current chaotic performance evaluation of EEG electrodes in some aspects such as electrochemical performance, stability, and so on. Moreover, the challenges and future expectations for EEG electrodes are analyzed.
Collapse
Affiliation(s)
- Haowen Yuan
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (J.Y.); (H.L.); (Q.Y.); (C.G.); (S.Z.)
| | - Yao Li
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (J.Y.); (H.L.); (Q.Y.); (C.G.); (S.Z.)
| | - Junjun Yang
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (J.Y.); (H.L.); (Q.Y.); (C.G.); (S.Z.)
| | - Hongjie Li
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (J.Y.); (H.L.); (Q.Y.); (C.G.); (S.Z.)
| | - Qinya Yang
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (J.Y.); (H.L.); (Q.Y.); (C.G.); (S.Z.)
| | - Cuiping Guo
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (J.Y.); (H.L.); (Q.Y.); (C.G.); (S.Z.)
| | - Shenmin Zhu
- State Key Laboratory of Metal Matrix Composites, Shanghai Jiao Tong University, Shanghai 200240, China; (H.Y.); (J.Y.); (H.L.); (Q.Y.); (C.G.); (S.Z.)
| | - Xiaokang Shu
- School of Mechanical Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
| |
Collapse
|
2
|
Neural Tissue Degeneration in Rosenthal's Canal and Its Impact on Electrical Stimulation of the Auditory Nerve by Cochlear Implants: An Image-Based Modeling Study. Int J Mol Sci 2020; 21:ijms21228511. [PMID: 33198187 PMCID: PMC7697226 DOI: 10.3390/ijms21228511] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 11/06/2020] [Accepted: 11/09/2020] [Indexed: 11/24/2022] Open
Abstract
Sensorineural deafness is caused by the loss of peripheral neural input to the auditory nerve, which may result from peripheral neural degeneration and/or a loss of inner hair cells. Provided spiral ganglion cells and their central processes are patent, cochlear implants can be used to electrically stimulate the auditory nerve to facilitate hearing in the deaf or severely hard-of-hearing. Neural degeneration is a crucial impediment to the functional success of a cochlear implant. The present, first-of-its-kind two-dimensional finite-element model investigates how the depletion of neural tissues might alter the electrically induced transmembrane potential of spiral ganglion neurons. The study suggests that even as little as 10% of neural tissue degeneration could lead to a disproportionate change in the stimulation profile of the auditory nerve. This result implies that apart from encapsulation layer formation around the cochlear implant electrode, tissue degeneration could also be an essential reason for the apparent inconsistencies in the functionality of cochlear implants.
Collapse
|
3
|
Abstract
OBJECTIVE It is known that the insertion of the intracochlear electrode is critical procedure because the damage around cochlear structures can deteriorate hearing restoration. To reduce the trauma during the electrode insertion surgery, we developed a thin and flexible intracochlear electrode array constructed with carbon nanotube (CNT) bundles. METHODS Each CNT bundle was used for an individual electrode channel after coated with parylene C for insulation. By encapsulating eight CNT bundles with silicone elastomer, an 8-channel intracochlear electrode array was fabricated. The mechanical and electrochemical characteristics were assessed to evaluate the flexibility and feasibility of the electrode as a stimulation electrode. The functionality of the electrode was confirmed by electrically evoked auditory brainstem responses (eABR) recorded from a rat. RESULTS The proposed electrode has a thickness of 135 μm at the apex and 395 μm at the base. It was demonstrated that the CNT bundle-based electrodes require 6-fold the lower insertion force than metal wire-based electrodes. The electrode impedance and the cathodic charge storage capacitance (CSCc) were 2.70 kΩ ∠-20.4° at 1 kHz and - 708 mC/cm2, respectively. The eABR waves III and V were observed when stimulation current is greater than 50 μA. CONCLUSION A thin and flexible CNT bundle-based intracochlear electrode array was successfully developed. The feasibility of the proposed electrode was shown in terms of mechanical and electrochemical characteristics. A proposed CNT bundle-based intracochlear electrode may reduce the risk of trauma during electrode insertion surgery.
Collapse
|
4
|
Bramini M, Alberini G, Colombo E, Chiacchiaretta M, DiFrancesco ML, Maya-Vetencourt JF, Maragliano L, Benfenati F, Cesca F. Interfacing Graphene-Based Materials With Neural Cells. Front Syst Neurosci 2018; 12:12. [PMID: 29695956 PMCID: PMC5904258 DOI: 10.3389/fnsys.2018.00012] [Citation(s) in RCA: 76] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 03/26/2018] [Indexed: 12/12/2022] Open
Abstract
The scientific community has witnessed an exponential increase in the applications of graphene and graphene-based materials in a wide range of fields, from engineering to electronics to biotechnologies and biomedical applications. For what concerns neuroscience, the interest raised by these materials is two-fold. On one side, nanosheets made of graphene or graphene derivatives (graphene oxide, or its reduced form) can be used as carriers for drug delivery. Here, an important aspect is to evaluate their toxicity, which strongly depends on flake composition, chemical functionalization and dimensions. On the other side, graphene can be exploited as a substrate for tissue engineering. In this case, conductivity is probably the most relevant amongst the various properties of the different graphene materials, as it may allow to instruct and interrogate neural networks, as well as to drive neural growth and differentiation, which holds a great potential in regenerative medicine. In this review, we try to give a comprehensive view of the accomplishments and new challenges of the field, as well as which in our view are the most exciting directions to take in the immediate future. These include the need to engineer multifunctional nanoparticles (NPs) able to cross the blood-brain-barrier to reach neural cells, and to achieve on-demand delivery of specific drugs. We describe the state-of-the-art in the use of graphene materials to engineer three-dimensional scaffolds to drive neuronal growth and regeneration in vivo, and the possibility of using graphene as a component of hybrid composites/multi-layer organic electronics devices. Last but not least, we address the need of an accurate theoretical modeling of the interface between graphene and biological material, by modeling the interaction of graphene with proteins and cell membranes at the nanoscale, and describing the physical mechanism(s) of charge transfer by which the various graphene materials can influence the excitability and physiology of neural cells.
Collapse
Affiliation(s)
- Mattia Bramini
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy.,Graphene Labs, Istituto Italiano di Tecnologia, Genova, Italy
| | - Giulio Alberini
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy.,Department of Experimental Medicine, Università degli Studi di Genova, Genova, Italy
| | - Elisabetta Colombo
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy.,Graphene Labs, Istituto Italiano di Tecnologia, Genova, Italy
| | - Martina Chiacchiaretta
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy.,Department of Experimental Medicine, Università degli Studi di Genova, Genova, Italy
| | - Mattia L DiFrancesco
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy.,Graphene Labs, Istituto Italiano di Tecnologia, Genova, Italy
| | - José F Maya-Vetencourt
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy
| | - Luca Maragliano
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy
| | - Fabio Benfenati
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy.,Graphene Labs, Istituto Italiano di Tecnologia, Genova, Italy.,Department of Experimental Medicine, Università degli Studi di Genova, Genova, Italy
| | - Fabrizia Cesca
- Center for Synaptic Neuroscience and Technology, Istituto Italiano di Tecnologia, Genova, Italy.,Graphene Labs, Istituto Italiano di Tecnologia, Genova, Italy
| |
Collapse
|
5
|
Kostarelos K, Vincent M, Hebert C, Garrido JA. Graphene in the Design and Engineering of Next-Generation Neural Interfaces. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2017; 29:1700909. [PMID: 28901588 DOI: 10.1002/adma.201700909] [Citation(s) in RCA: 87] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 05/31/2017] [Indexed: 05/24/2023]
Abstract
Neural interfaces are becoming a powerful toolkit for clinical interventions requiring stimulation and/or recording of the electrical activity of the nervous system. Active implantable devices offer a promising approach for the treatment of various diseases affecting the central or peripheral nervous systems by electrically stimulating different neuronal structures. All currently used neural interface devices are designed to perform a single function: either record activity or electrically stimulate tissue. Because of their electrical and electrochemical performance and their suitability for integration into flexible devices, graphene-based materials constitute a versatile platform that could help address many of the current challenges in neural interface design. Here, how graphene and other 2D materials possess an array of properties that can enable enhanced functional capabilities for neural interfaces is illustrated. It is emphasized that the technological challenges are similar for all alternative types of materials used in the engineering of neural interface devices, each offering a unique set of advantages and limitations. Graphene and 2D materials can indeed play a commanding role in the efforts toward wider clinical adoption of bioelectronics and electroceuticals.
Collapse
Affiliation(s)
- Kostas Kostarelos
- Nanomedicine Lab, Faculty of Biology Medicine & Health, National Graphene Institute, University of Manchester, AV Hill Building, Manchester, M13 9PT, U.K
| | - Melissa Vincent
- Nanomedicine Lab, Faculty of Biology Medicine & Health, National Graphene Institute, University of Manchester, AV Hill Building, Manchester, M13 9PT, U.K
| | - Clement Hebert
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, 08193, Barcelona, Spain
| | - Jose A Garrido
- Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC and The Barcelona Institute of Science and Technology, Campus UAB, Bellaterra, 08193, Barcelona, Spain
- ICREA, Pg. Lluís Companys 23, 08010, Barcelona, Spain
| |
Collapse
|
6
|
|
7
|
Abstract
Here I identify two gaps in cochlear implants that have been limiting their performance and acceptance. First, cochlear implant performance has remained largely unchanged, despite the number of publications tripling per decade in the last 30 years. Little has been done so far to address a fundamental limitation in the electrode-to-neuron interface, with the electrode size being a thousand times larger than the neuron diameter while the number of electrodes being a thousand times less. Both the small number and the large size of electrodes produce broad spatial activation and poor frequency resolution that limit current cochlear implant performance. Second, a similarly rapid growth in cochlear implant volume has not produced an expected decrease in unit price in the same period. The high cost contributes to low market penetration rate, which is about 20% in developed countries and less than 1% in developing countries. I will discuss changes needed in both research strategy and business practice to close the gap between prosthetic and normal hearing as well as that between haves and have-nots.
Collapse
|
8
|
Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion. Biomed Microdevices 2016; 17:32. [PMID: 25681972 DOI: 10.1007/s10544-015-9941-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
An atraumatic cochlear electrode array has become indispensable to high-performance cochlear implants such as electric acoustic stimulation (EAS), wherein the preservation of residual hearing is significant. For an atraumatic implantation, we propose and demonstrate a new improved design of a cochlear electrode array based on liquid crystal polymer (LCP), which can be fabricated by precise batch processes and a thermal lamination process, in contrast to conventional wire-based cochlear electrode arrays. Using a thin-film process of LCP-film-mounted silicon wafer and thermal press lamination, we devise a multi-layered structure with variable layers of LCP films to achieve a sufficient degree of basal rigidity and a flexible tip. A peripheral blind via and self-aligned silicone elastomer molding process can reduce the width of the array. Measuring the insertion and extraction forces in a human scala tympani model, we investigate five human temporal bone insertion trials and record electrically evoked auditory brainstem responses (EABR) acutely in a guinea pig model. The diameters of the finalized electrode arrays are 0.3 mm (tip) and 0.75 mm (base). The insertion force with a displacement of 8 mm from a round window and the maximum extraction force are 2.4 mN and 34.0 mN, respectively. The electrode arrays can be inserted from 360° to 630° without trauma at the basal turn. The EABR data confirm the efficacy of the array. A new design of LCP-based cochlear electrode array for atraumatic implantation is fabricated. Verification indicates that foretells the development of an atraumatic cochlear electrode array and clinical implant.
Collapse
|
9
|
Tavartkiladze GA. [The current state and prospects of the development of cochlear implantation]. Vestn Otorinolaringol 2015; 80:4-9. [PMID: 26331167 DOI: 10.17116/otorino20158034-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
This paper reports the literature data summarizing the recent achievements in the field of rehabilitation of the patients suffering from deafness and serious impairment of hearing with the use of cochlear implantation. Much attention is given to the limitations of the modern strategies of signal processing and the prospects for the further development of scientific research in this area. Special emphasis is laid on recent progress in audiology including the binaural cochlear implant technology and the electroacoustic stimulation facilitating significant improvement in the outcomes of rehabilitation of the patients. Also, the prospects for the further developments in the field of construction of the new cochlear implantations systems, the novel algorithms for information processing, and the original therapeutic modalities designed to stimulated the growth of axonal processed of the spiral ganglion and their outgrowths into the electrode system.
Collapse
Affiliation(s)
- G A Tavartkiladze
- National Research Centre for Audiology and Hearing Rehabilitation, Russian Federal Medico-Biological Agency, Moscow, Russia, 117513; Russian Medical Academy of Post-Graduate Education, Russian Ministry of Health, Moscow, Russia, 123995
| |
Collapse
|
10
|
Striem-Amit E, Bubic R, Amedi A. Neurophysiological Mechanisms Underlying Plastic Changes and Rehabilitation following Sensory Loss in Blindness and Deafness. Front Neurosci 2013. [DOI: 10.1201/9781439812174-27] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/25/2023] Open
|
11
|
Wallace GG, Higgins MJ, Moulton SE, Wang C. Nanobionics: the impact of nanotechnology on implantable medical bionic devices. NANOSCALE 2012; 4:4327-4347. [PMID: 22695635 DOI: 10.1039/c2nr30758h] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The nexus of any bionic device can be found at the electrode-cellular interface. Overall efficiency is determined by our ability to transfer electronic information across that interface. The nanostructure imparted to electrodes plays a critical role in controlling the cascade of events that determines the composition and structure of that interface. With commonly used conductors: metals, carbon and organic conducting polymers, a number of approaches that promote control over structure in the nanodomain have emerged in recent years with subsequent studies revealing a critical dependency between nanostructure and cellular behaviour. As we continue to develop our understanding of how to create and characterise electromaterials in the nanodomain, this is expected to have a profound effect on the development of next generation bionic devices. In this review, we focus on advances in fabricating nanostructured electrodes that present new opportunities in the field of medical bionics. We also briefly evaluate the interactions of living cells with the nanostructured electromaterials, in addition to highlighting emerging tools used for nanofabrication and nanocharacterisation of the electrode-cellular interface.
Collapse
Affiliation(s)
- G G Wallace
- ARC Centre of Excellence for Electromaterials Science (ACES), Intelligent Polymer Research Institute, AIIM Facility, Innovation Campus, University of Wollongong, NSW 2522, Australia
| | | | | | | |
Collapse
|
12
|
Chikar JA, Hendricks JL, Richardson-Burns SM, Raphael Y, Pfingst BE, Martin DC. The use of a dual PEDOT and RGD-functionalized alginate hydrogel coating to provide sustained drug delivery and improved cochlear implant function. Biomaterials 2011; 33:1982-90. [PMID: 22182748 DOI: 10.1016/j.biomaterials.2011.11.052] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2011] [Accepted: 11/20/2011] [Indexed: 11/30/2022]
Abstract
Cochlear implants provide hearing by electrically stimulating the auditory nerve. Implant function can be hindered by device design variables, including electrode size and electrode-to-nerve distance, and cochlear environment variables, including the degeneration of the auditory nerve following hair cell loss. We have developed a dual-component cochlear implant coating to improve both the electrical function of the implant and the biological stability of the inner ear, thereby facilitating the long-term perception of sound through a cochlear implant. This coating is a combination of an arginine-glycine-aspartic acid (RGD)-functionalized alginate hydrogel and the conducting polymer poly(3, 4-ethylenedioxythiophene) (PEDOT). Both in vitro and in vivo assays on the effects of these electrode coatings demonstrated improvements in device performance. We found that the coating reduced electrode impedance, improved charge delivery, and locally released significant levels of a trophic factor into cochlear fluids. This coating is non-cytotoxic, clinically relevant, and has the potential to significantly improve the cochlear implant user's experience.
Collapse
Affiliation(s)
- Jennifer A Chikar
- Neuroscience Program, University of Michigan, 4137 Undergraduate Research Bldg, 204 Washtenaw Ave., Ann Arbor, MI 48109-2215, USA.
| | | | | | | | | | | |
Collapse
|
13
|
Yoshida H, Kanda Y, Takahashi H, Miyamoto I, Chiba K. Observation of cortical activity during speech stimulation in prelingually deafened adults with cochlear implantation by positron emission tomography-computed tomography. Ann Otol Rhinol Laryngol 2011; 120:499-504. [PMID: 21922972 DOI: 10.1177/000348941112000802] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVES We evaluated the cortical activity of 2 successful prelingually deafened adult cochlear implant (CI) users who have been trained by auditory-verbal/oral communication since childhood. METHODS Changes in regional cerebral blood flow were measured by positron emission tomography using '8F-fluorodeoxyglucose while the subjects were receiving auditory language stimuli by listening to a story. Ten normal-hearing volunteers were observed as age-matched control subjects. RESULTS In both cases, the auditory-related regions, when compared to same regions in the control subjects, showed hypermetabolism in the left dorsolateral prefrontal cortex and the left precentral gyrus--similar to that in successful CI users who are prelingually deafened children or postlingually deafened adults. Both subjects had the ability to activate these areas, and this ability might be one of the reasons that accounts for such exceptionally good performance in older prelingually deaf CI users. As for the visual-related regions, hypometabolism was observed in Brodmann areas 18 and 19, and this finding might be related to the intensive auditory-verbal/oral education that the subjects had received since childhood. CONCLUSIONS Despite the limits imposed by the small sample size and the spatial resolution of positron emission tomography, this study yielded insights into the nature of the brain plasticity in prelingually deafened adults who are successful CI users.
Collapse
Affiliation(s)
- Haruo Yoshida
- Department of Otolaryngology-Head and Neck Surgery, Nagasaki University Graduate School of Biomedical Sciences, Japan
| | | | | | | | | |
Collapse
|
14
|
Striem-Amit E, Bubic R, Amedi A. Neurophysiological Mechanisms Underlying Plastic Changes and Rehabilitation following Sensory Loss in Blindness and Deafness. Front Neurosci 2011. [DOI: 10.1201/b11092-27] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
15
|
|
16
|
Stimulation for the Return of Hearing. Neuromodulation 2009. [DOI: 10.1016/b978-0-12-374248-3.00059-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
|
17
|
Yoshida H, Kanda Y, Miyamoto I, Fukuda T, Takahashi H. Cochlear implantation on prelingually deafened adults. Auris Nasus Larynx 2008; 35:349-52. [PMID: 18248927 DOI: 10.1016/j.anl.2007.10.003] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2007] [Revised: 09/13/2007] [Accepted: 10/02/2007] [Indexed: 11/19/2022]
Affiliation(s)
- Haruo Yoshida
- Division of Otorhinolaryngology, Department of Translational Medical Science, Nagasaki University Graduate School of Biomedical Sciences, Japan.
| | | | | | | | | |
Collapse
|
18
|
Lu H, Chestek CA, Shaw KM, Chiel HJ. Selective extracellular stimulation of individual neurons in ganglia. J Neural Eng 2008; 5:287-309. [PMID: 18714126 DOI: 10.1088/1741-2560/5/3/003] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Selective control of individual neurons could clarify neural functions and aid disease treatments. To target specific neurons, it may be useful to focus on ganglionic neuron clusters, which are found in the peripheral nervous system in vertebrates. Because neuron cell bodies are found primarily near the surface of invertebrate ganglia, and often found near the surface of vertebrate ganglia, we developed a technique for controlling individual neurons extracellularly using the buccal ganglia of the marine mollusc Aplysia californica as a model system. We experimentally demonstrated that anodic currents can selectively activate an individual neuron and cathodic currents can selectively inhibit an individual neuron using this technique. To define spatial specificity, we studied the minimum currents required for stimulation, and to define temporal specificity, we controlled firing frequencies up to 45 Hz. To understand the mechanisms of spatial and temporal specificity, we created models using the NEURON software package. To broadly predict the spatial specificity of arbitrary neurons in any ganglion sharing similar geometry, we created a steady-state analytical model. A NEURON model based on cat spinal motor neurons showed responses to extracellular stimulation qualitatively similar to those of the Aplysia NEURON model, suggesting that this technique could be widely applicable to vertebrate and human peripheral ganglia having similar geometry.
Collapse
Affiliation(s)
- Hui Lu
- Department of Biology, Case Western Reserve University, Cleveland, OH 44106, USA.
| | | | | | | |
Collapse
|
19
|
Wilson BS, Dorman MF. Cochlear implants: a remarkable past and a brilliant future. Hear Res 2008; 242:3-21. [PMID: 18616994 DOI: 10.1016/j.heares.2008.06.005] [Citation(s) in RCA: 398] [Impact Index Per Article: 24.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2007] [Revised: 06/08/2008] [Accepted: 06/11/2008] [Indexed: 11/18/2022]
Abstract
The aims of this paper are to (i) provide a brief history of cochlear implants; (ii) present a status report on the current state of implant engineering and the levels of speech understanding enabled by that engineering; (iii) describe limitations of current signal processing strategies; and (iv) suggest new directions for research. With current technology the "average" implant patient, when listening to predictable conversations in quiet, is able to communicate with relative ease. However, in an environment typical of a workplace the average patient has a great deal of difficulty. Patients who are "above average" in terms of speech understanding, can achieve 100% correct scores on the most difficult tests of speech understanding in quiet but also have significant difficulty when signals are presented in noise. The major factors in these outcomes appear to be (i) a loss of low-frequency, fine structure information possibly due to the envelope extraction algorithms common to cochlear implant signal processing; (ii) a limitation in the number of effective channels of stimulation due to overlap in electric fields from electrodes; and (iii) central processing deficits, especially for patients with poor speech understanding. Two recent developments, bilateral implants and combined electric and acoustic stimulation, have promise to remediate some of the difficulties experienced by patients in noise and to reinstate low-frequency fine structure information. If other possibilities are realized, e.g., electrodes that emit drugs to inhibit cell death following trauma and to induce the growth of neurites toward electrodes, then the future is very bright indeed.
Collapse
Affiliation(s)
- Blake S Wilson
- Division of Otolaryngology, Head and Neck Surgery, Department of Surgery, Duke University Medical Center, Durham, NC 27710, USA.
| | | |
Collapse
|
20
|
Leung BK, Biran R, Underwood CJ, Tresco PA. Characterization of microglial attachment and cytokine release on biomaterials of differing surface chemistry. Biomaterials 2008; 29:3289-97. [PMID: 18485471 DOI: 10.1016/j.biomaterials.2008.03.045] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2008] [Accepted: 03/26/2008] [Indexed: 11/16/2022]
Abstract
The clinical usefulness of central nervous system recording electrodes is currently limited by inconsistent long-term performance that is believed to be governed by the brain tissue response to the implant. In this study, we observed persistent macrophage biomarker expression at the biotic-abiotic interface surrounding implanted electrodes over a 12-week indwelling period. Using the cell type-specific marker CD11b to examine the cells attached to electrodes retrieved over the indwelling period, we found that most of the cells were activated microglia, the resident macrophage of brain tissue, indicating that the implanted electrodes behave as a persistent inflammatory stimulus. To determine the potential usefulness of different materials as coatings for implanted electrodes, we examined brain-derived microglial cell attachment and cytokine release on a number of medically relevant materials. Our results suggest that activated microglia attach to many of the materials used as external coatings for electrode manufacture, and likely serve as a source of pro-inflammatory and neurotoxic cytokines that may be responsible for reducing the biocompatibility of such implants. Our results also indicate that low protein-binding coatings may be useful in reducing microglial attachment upon implantation in brain tissue and may provide a means of improving electrode biocompatibility.
Collapse
Affiliation(s)
- Braden K Leung
- The Keck Center for Tissue Engineering, Department of Bioengineering, College of Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | | | | | | |
Collapse
|
21
|
Abstract
Implantable devices such as cardiac pacemakers, drug-delivery systems, and defibrillators have had a tremendous impact on the quality of live for many disabled people. To date, many devices have been developed for implantation into various parts of the human body. In this paper, we focus on devices implanted in the head. In particular, we describe the technologies necessary to create implantable microimagers. Design, fabrication, and implementation issues are discussed vis-à-vis two examples of implantable microimagers; the retinal prosthesis and in vivo neuro-microimager. Testing of these devices in animals verify the use of the microimagers in the implanted state. We believe that further advancement of these devices will lead to the development of a new method for medical and scientific applications.
Collapse
|
22
|
Micco AG, Richter CP. Tissue resistivities determine the current flow in the cochlea. Curr Opin Otolaryngol Head Neck Surg 2008; 14:352-5. [PMID: 16974151 DOI: 10.1097/01.moo.0000244195.04926.a0] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW In individuals with severe to profound hearing loss, cochlear implants bypass normal inner ear function by applying electrical current directly into the cochlea, thereby stimulating cochlear nerve fibers. Stimulating discrete populations of spiral ganglion cells in cochlear implant users' ears is similar to the encoding of small acoustic frequency bands in a normal-hearing person's ear. Thus, spiral ganglion cells stimulated by an electrode convey the information contained by a small acoustic frequency band. Problems that refer to the current spread and subsequent nonselective stimulation of spiral ganglion cells in the cochlea are reviewed. RECENT FINDINGS Cochlear anatomy and tissue properties determine the current path in the cochlea. Current spreads largely via scala tympani and across turns. While most of the current leaves the cochlea via the modiolus, the facial canal and the round window constitute additional natural escape paths for the current from the cochlea. Moreover, degenerative processes change tissue resistivities and thus may affect current spread in the cochlea. SUMMARY Electrode design and coding strategies may result in more spatial stimulation of spiral ganglion cells, resulting in a better performance of the electrode-tissue interface.
Collapse
Affiliation(s)
- Alan Gerard Micco
- Northwestern University Feinberg School of Medicine, Department of Otolaryngology-Head and Neck Surgery, The Hugh Knowles Center, Chicago, Illinois , USA.
| | | |
Collapse
|