1
|
Safe Follow-Up after Endovascular Aortic Repair with Unenhanced MRI: The SAFEVAR Study. Diagnostics (Basel) 2022; 13:diagnostics13010020. [PMID: 36611311 PMCID: PMC9818075 DOI: 10.3390/diagnostics13010020] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/05/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022] Open
Abstract
We aimed to investigate whether unenhanced magnetic resonance imaging (MRI) could represent a safe and highly sensitive tool for endoleak screening in patients treated with endovascular aneurysm repair (EVAR) using computed tomography angiography (CTA) as a reference standard. Patients who underwent CTA for EVAR follow-up at our institution were prospectively enrolled. All MRI examinations were performed with a 1.5 T unit. The true-FISP and HASTE sequences of the MRI scans were assessed for the presence of hyperintensity within the aneurysm sac outside the graft, whereas phase-contrast through-plane sequences were used for blood flow quantification. We included 45 patients, 5 (11%) of whom were female. The median age was 73 years (IQR 68−78 years). Among our patients, 19 (42%) were positive for endoleaks at CTA, of whom 13 (68%) had type II endoleaks and 6 (32%) had type I endoleaks. There were no significant differences in age, sex, aneurysm type, prosthesis type, or contrast-to-noise ratio between hyperintensity and thrombus between patients with and without endoleaks (p > 0.300). The combined evaluation of true-FISP and HASTE yielded 100% sensitivity (95% CI: 79−100%) and 19% specificity (95% CI: 7−40%). Patients with a positive CTA had a median thrombus flow of 0.06 L/min (IQR 0.03−0.23 L/min), significantly greater than that of patients with a negative CTA (p = 0.007). Setting a threshold at 0.01 L/min, our MRI protocol yielded 100% sensitivity, 56% specificity, and an AUC of 0.76 (95% CI 0.60−0.91). In conclusion, unenhanced MRI has perfect sensitivity for endoleak detection, although with subpar specificity that could be improved with phase-contrast flow analysis.
Collapse
|
2
|
Kawada H, Goshima S, Sakurai K, Noda Y, Kajita K, Tanahashi Y, Kawai N, Ishida N, Shimabukuro K, Doi K, Matsuo M. Utility of Noncontrast Magnetic Resonance Angiography for Aneurysm Follow-Up and Detection of Endoleaks after Endovascular Aortic Repair. Korean J Radiol 2020; 22:513-524. [PMID: 33543842 PMCID: PMC8005350 DOI: 10.3348/kjr.2020.0001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2019] [Revised: 06/02/2020] [Accepted: 06/22/2020] [Indexed: 11/17/2022] Open
Abstract
Objective To assess the noncontrast two-dimensional single-shot balanced turbo-field-echo magnetic resonance angiography (b-TFE MRA) features of the abdominal aortic aneurysm (AAA) status following endovascular aneurysm repair (EVAR) and evaluate to detect endoleaks (ELs). Materials and Methods We examined four aortic stent-grafts in a phantom study to assess the degree of metallic artifacts. We enrolled 46 EVAR-treated patients with AAA and/or common iliac artery aneurysm who underwent both computed tomography angiography (CTA) and b-TFE MRA after EVAR. Vascular measurements on CTA and b-TFE MRA were compared, and signal intensity ratios (SIRs) of the aneurysmal sac were correlated with the size changes in the AAA after EVAR (AAA prognoses). Furthermore, we examined six feasible b-TFE MRA features for the assessment of ELs. Results There were robust intermodality (r = 0.92–0.99) correlations and interobserver (intraclass correlation coefficient = 0.97–0.99) agreement. No significant differences were noted between SIRs and aneurysm prognoses. Moreover, “mottled high-intensity” and “creeping high-intensity with the low-band rim” were recognized as significant imaging findings suspicious for the presence of ELs (p < 0.001), whereas “no signal black spot” and “layered high-intensity area” were determined as significant for the absence of ELs (p < 0.03). Based on the two positive features, sensitivity, specificity, and accuracy for the detection of ELs were 77.3%, 91.7%, and 84.8%, respectively. Furthermore, the k values (0.40–0.88) displayed moderate-to-almost perfect agreement. Conclusion Noncontrast MRA could be a promising imaging modality for ascertaining patient follow-up after EVAR.
Collapse
Affiliation(s)
- Hiroshi Kawada
- Department of Radiology, Gifu University Hospital, Gifu, Japan
| | - Satoshi Goshima
- Department of Radiology, Gifu University Hospital, Gifu, Japan.,Department of Diagnostic Radiology and Nuclear Medicine, Hamamatsu University School of Medicine, Hamamatsu, Japan.
| | - Kota Sakurai
- Department of Radiology, Chuno Kosei Hospital, Seki, Japan
| | - Yoshifumi Noda
- Department of Radiology, Gifu University Hospital, Gifu, Japan
| | - Kimihiro Kajita
- Department of Radiology Services, Gifu University Hospital, Gifu, Japan
| | | | - Nobuyuki Kawai
- Department of Radiology, Gifu University Hospital, Gifu, Japan
| | - Narihiro Ishida
- Department of General and Cardiothoracic Surgery, Gifu University Hospital, Gifu, Japan
| | - Katsuya Shimabukuro
- Department of General and Cardiothoracic Surgery, Gifu University Hospital, Gifu, Japan
| | - Kiyoshi Doi
- Department of General and Cardiothoracic Surgery, Gifu University Hospital, Gifu, Japan
| | - Masayuki Matsuo
- Department of Radiology, Gifu University Hospital, Gifu, Japan
| |
Collapse
|
3
|
Oliveira-Pinto J, Ferreira RS, Oliveira NFG, Hoeks S, Van Rijn MJ, Raa ST, Mansilha A, Verhagen HJM, Gonçalves FB. Total Luminal Volume Predicts Risk after Endovascular Aneurysm Repair. Eur J Vasc Endovasc Surg 2020; 59:918-927. [PMID: 32197997 DOI: 10.1016/j.ejvs.2020.02.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2019] [Revised: 01/09/2020] [Accepted: 02/17/2020] [Indexed: 01/05/2023]
Abstract
OBJECTIVE Large aneurysm diameter represents a well known predictor of late complications after endovascular aneurysm repair (EVAR). However, the role of the thrombus free lumen inside the abdominal aortic aneurysm (AAA) sac is not clear. It was hypothesised that greater luminal volume represents a relevant risk factor for late complications after EVAR. METHODS A retrospective cohort analysis was performed including all patients undergoing EVAR from 2005 to 2016 at a tertiary referral institution. Pre-operative AAA lumen volume was measured in centre lumen line reconstructions and patients were stratified into quartiles according to luminal volume. The primary endpoint was freedom from AAA related complications. Secondary endpoints were freedom from neck events (type 1A endoleak, migration >5 mm or any pre-emptive neck related intervention), iliac related events (type 1B endoleak or pre-emptive iliac related intervention), and overall survival. RESULTS Four hundred and four patients were included: 101 in the first quartile (Q1; <61 cm3). Patients with higher luminal volumes had wider, shorter, and more angulated proximal necks. There were more ruptured AAAs, more aorto-uni-iliac implanted devices and patients outside neck instructions for use in the 4th quartile. Five year freedom from AAA related complications was 79%, 66%, 58% and 56%, respectively (p = .007). At five years, freedom from neck related events was 86%, 84%, 73%, and 71%, respectively, for the four groups (p = .009), and freedom from iliac related events was 96%, 91%, 88%, and 88%, respectively (p = .335). On multivariable analysis, luminal volume was an independent predictor of late complications (Q4 vs. Q1 - hazard ratio: 1.91, 95% confidence interval 1.01-3.6, p = .046). Overall survival at five years was not affected by lumen volume (p = .75). CONCLUSION AAA luminal volume represents an important risk factor for AAA related complications. This information may be considered when deciding tailoring surveillance protocols after EVAR. However, larger studies are needed to validate this hypothesis.
Collapse
Affiliation(s)
- José Oliveira-Pinto
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands; Department of Angiology and Vascular Surgery, Centro Hospitalar São João, Porto, Portugal; Department of Surgery and Physiology, Faculdade de Medicina da Univesidade do Porto, Porto, Portugal.
| | - Rita S Ferreira
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands; Department of Angiology and Vascular Surgery, Hospital de Santa Marta, Centro Hospitalar de Lisboa Central, Lisbon, Portugal; NOVA Medical School, Lisbon, Portugal
| | - Nelson F G Oliveira
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands; Department of Angiology and Vascular Surgery, Hospital do Divino Espírito Santo, Ponta Delgada, Azores, Portugal
| | - Sanne Hoeks
- Department of Anaesthetics, Erasmus University Medical Centre, Rotterdam, the Netherlands
| | - Marie J Van Rijn
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands
| | - Sander T Raa
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands
| | - Armando Mansilha
- Department of Angiology and Vascular Surgery, Centro Hospitalar São João, Porto, Portugal; Department of Surgery and Physiology, Faculdade de Medicina da Univesidade do Porto, Porto, Portugal
| | - Hence J M Verhagen
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands
| | - Frederico B Gonçalves
- Department of Vascular Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands; Department of Angiology and Vascular Surgery, Hospital de Santa Marta, Centro Hospitalar de Lisboa Central, Lisbon, Portugal; NOVA Medical School, Lisbon, Portugal
| |
Collapse
|
4
|
Leach JR, Kao E, Zhu C, Saloner D, Hope MD. On the Relative Impact of Intraluminal Thrombus Heterogeneity on Abdominal Aortic Aneurysm Mechanics. J Biomech Eng 2019; 141:111010. [PMID: 31253989 PMCID: PMC6808003 DOI: 10.1115/1.4044143] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 06/14/2019] [Indexed: 01/31/2023]
Abstract
Intraluminal thrombus (ILT) is present in the majority of abdominal aortic aneurysms (AAA) of a size warranting consideration for surgical or endovascular intervention. The rupture risk of AAAs is thought to be related to the balance of vessel wall strength and the mechanical stress caused by systemic blood pressure. Previous finite element analyses of AAAs have shown that ILT can reduce and homogenize aneurysm wall stress. These works have largely considered ILT to be homogeneous in mechanical character or have idealized a stiffness distribution through the thrombus thickness. In this work, we use magnetic resonance imaging (MRI) to delineate the heterogeneous composition of ILT in 7 AAAs and perform patient-specific finite element analysis under multiple conditions of ILT layer stiffness disparity. We find that explicit incorporation of ILT heterogeneity in the finite element analysis is unlikely to substantially alter major stress analysis predictions regarding aneurysm rupture risk in comparison to models assuming a homogenous thrombus, provided that the maximal ILT stiffness is the same between models. Our results also show that under a homogeneous ILT assumption, the choice of ILT stiffness from values common in the literature can result in significantly larger variations in stress predictions compared to the effects of thrombus heterogeneity.
Collapse
Affiliation(s)
- Joseph R Leach
- Department of Radiology andBiomedical Imaging,University of California, San Francisco,513 Parnassus Avenue Suite S-261,Box 0628,San Francisco, CA 94143e-mail:
| | - Evan Kao
- Department of Radiology andBiomedical Imaging,University of California, San Francisco,San Francisco, CA 94143e-mail:
| | - Chengcheng Zhu
- Department of Radiology andBiomedical Imaging,University of California, San Francisco,San Francisco, CA 94143e-mail:
| | - David Saloner
- Department of Radiology andBiomedical Imaging,University of California, San Francisco,San Francisco, CA 94143e-mail:
| | - Michael D Hope
- Department of Radiology andBiomedical Imaging,University of California, San Francisco,San Francisco, CA 94143e-mail:
| |
Collapse
|
5
|
Evolution of Computed Tomography Imaging the First Year after Endovascular Sealing of Infrarenal Aortic Aneurysms Using the Nellix Device. Ann Vasc Surg 2017; 47:223-229. [PMID: 28911963 DOI: 10.1016/j.avsg.2017.07.038] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2017] [Revised: 07/20/2017] [Accepted: 07/21/2017] [Indexed: 11/23/2022]
Abstract
BACKGROUND The Nellix endovascular aneurysm sealing (EVAS) system is an alternative endovascular treatment option for infrarenal aortic aneurysms (AAAs), with a unique appearance on computed tomography angiography (CTA). Normal evolution of post-EVAS CTA appearance follow-up is still largely unknown and important to timely detect eventual complications. The objective is to assess the normal appearance of CTA images 30 days and 1 year after EVAS in 50 consecutive patients. METHODS Fifty patients treated with Nellix EVAS for an infrarenal AAA were included from 3 hospitals. Using dedicated software, a total of 150 CTA scans were analyzed by predetermined variables per anatomical segment. RESULTS Thirty days post-EVAS, there was a slight, but not statistically significant, increase in AAA diameter that returned to the preoperative value after 1 year. A shift in total aortic volume distribution was observed without changing aortic diameter, including a trend toward a decreased thrombus volume (85.6 ± 49.1 mL and 78.8 ± 35.5 mL at 30 days and 1 year, respectively, P < 0.242) and a slight, but statistically significant, increase in polymer volume (68.2 ± 34.1 mL and 71.9 ± 35.2 mL at 30 days and 1 year, respectively, P < 0.001). The β-angle (P = 0.06) and iliac artery angulation (P < 0.001) decreased after implant. The latter returned to its original state after 1 year, whereas the neck straightening remained. Over time, there was a significant decrease in radiodensity in the middle of the polymer-filled endobags with an increase at its edges (P < 0.05). Thrombus radiodensity significantly increased over the first year (P < 0.05). Diameters of the infrarenal neck and common iliac arteries remained unchanged, no endoleaks were observed, and the position of the device was stable. CONCLUSIONS Change of CT appearance after EVAS is unique, and as such, the judgment of these images requires experience. The appearance of the endobags in respect to volume and radiodensity differ from classic EVAR. Normal changes over time are observed in aortoiliac angulation, volumes, and radiodensities.
Collapse
|
6
|
Cornelissen SA, Verhagen HJ, van Herwaarden JA, Vonken EJP, Moll FL, Bartels LW. Lack of thrombus organization in nonshrinking aneurysms years after endovascular abdominal aortic aneurysm repair. J Vasc Surg 2012; 56:938-42. [DOI: 10.1016/j.jvs.2012.03.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2011] [Revised: 02/27/2012] [Accepted: 03/04/2012] [Indexed: 10/28/2022]
|
7
|
Cornelissen SA, van der Laan MJ, Vincken KL, Vonken EJPA, Viergever MA, Bakker CJ, Moll FL, Bartels LW. Use of Multispectral MRI to Monitor Aneurysm Sac Contents After Endovascular Abdominal Aortic Aneurysm Repair. J Endovasc Ther 2011; 18:274-9. [DOI: 10.1583/10-3271.1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
8
|
Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms. Eur Radiol 2008; 19:1223-31. [PMID: 19104821 DOI: 10.1007/s00330-008-1253-x] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2008] [Revised: 09/28/2008] [Accepted: 10/29/2008] [Indexed: 12/19/2022]
Abstract
This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen's k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.
Collapse
|
9
|
Kajimoto M, Shimono T, Hirano K, Miyake Y, Kato N, Imanaka-Yoshida K, Shimpo H, Miyamoto K. Basic fibroblast growth factor slow release stent graft for endovascular aortic aneurysm repair: A canine model experiment. J Vasc Surg 2008; 48:1306-14. [DOI: 10.1016/j.jvs.2008.05.060] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2007] [Revised: 05/15/2008] [Accepted: 05/17/2008] [Indexed: 11/16/2022]
|
10
|
Springer F, Schlierf R, Pfeffer JG, Mahnken AH, Schnakenberg U, Schmitz-Rode T. Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study. Eur Radiol 2007; 17:2589-97. [PMID: 17340105 DOI: 10.1007/s00330-007-0583-4] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2006] [Revised: 12/03/2006] [Accepted: 01/09/2007] [Indexed: 11/24/2022]
Abstract
A feasibility study on a completely digital telemetric pressure sensor (TPS) to detect endoleaks was performed in an in vitro model of an abdominal aortic aneurysm (AAA). An endovascular-stented AAA silicone model with different types (I-III) and sizes (3-11 French) of endoleaks was created and pulsatile pressure was applied with physiological flow and pressure rates [mean intraaortic pressure (IAP): 95-130 mmHg] and different degrees of thrombosis of the aneurysm sac. Aneurysm sac pressure (ASP) was measured with the TPS and with wired pressure sensors (WPS) as a reference. Statistical analysis included paired t-test, Pearson's correlation analysis and Bland-Altman plots. After opening an endoleak, the mean ASP increased significantly (P < 0.0001) from 15 to almost 95% of the mean IAP depending on endoleak type and size. ASP could be measured accurately with the TPS and the WPS. The telemetric and wired ASP increase showed a high Pearson's correlation coefficient (r) for a non-thrombosed (r = 0.97) and a thrombosed (r = 0.96) aneurysm sac. In an in vitro silicone model, the newly designed telemetric pressure sensor was able to detect the occurrence of an endoleak in a non-invasive way and might be a valuable device for follow-up of endovascular AAA repair.
Collapse
Affiliation(s)
- Fabian Springer
- Helmholtz-Institute for Biomedical Engineering, Applied Medical Engineering, RWTH Aachen University, Pauwelsstrasse 20, 52074, Aachen, Germany.
| | | | | | | | | | | |
Collapse
|
11
|
Pitton MB. Diagnosis and management of endoleaks after endovascular aneurysm repair: role of MRI. ACTA ACUST UNITED AC 2006; 31:339-46. [PMID: 16314987 DOI: 10.1007/s00261-005-0370-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Affiliation(s)
- Michael B Pitton
- Department of Radiology, University Hospital of Mainz, Langenbeckstr. 1, Mainz 55131, Germany.
| |
Collapse
|
12
|
Kajimoto M, Shimono T, Hirano K, Miyake Y, Sawada Y, Kato N, Hirata H, Imanaka-Yoshida K, Nishikawa M, Yoshida T, Shimpo H, Horiuchi T, Miyamoto K. Development of a new method for endovascular aortic repair: combination therapy of cell transplantation and stent grafts with a drug delivery system. Circulation 2006; 114:I378-83. [PMID: 16820604 DOI: 10.1161/circulationaha.105.001016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Endovascular aortic repair by stent grafts (S/Gs) has been developed as a less invasive treatment for aortic aneurysms. However, some aneurysmal cavities can remain without organization, causing re-expansion. We demonstrated previously that transplantation of a cell combination (myoblasts and fibroblasts) promoted thrombus organization in a rat model. We also developed basic fibroblast growth factor (bFGF) slow-delivery S/Gs coated with elastin and impregnated with bFGF. Here, we evaluated the effects of cell transplantation combined with bFGF slow release on canine thoracic aortic aneurysmal sacs after S/Gs repair. METHODS AND RESULTS Thoracic aortic aneurysms were surgically created with jugular vein patches in 15 beagles. Myoblasts and fibroblasts of autologous skeletal muscle were isolated and cultured for cell transplantation. The S/Gs had 6 holes and produced endoleaks in the excluded cavities. Collagen gel (gel group, n=5) or a mixture of skeletal myoblasts and fibroblasts with collagen gel (cell group, n=5) were injected into the aneurysmal sacs excluded by the S/Gs. We also studied the effects of combined therapy of bFGF slow-release S/Gs and cell transplantation (hybrid group, n=5). After 14 days, histological analyses revealed that the excluded aneurysmal cavities of the gel group were filled with fresh thrombus, whereas the excluded cavities in the cell-transplanted groups were occupied by organized tissue. The percentages of the organized areas relative to the excluded cavities, evaluated by Masson's trichrome staining, were 18.1+/-4.0%, 52.6+/-4.0%, and 77.1+/-6.9% in the gel, cell, and hybrid groups, respectively. Collagen fibers had already appeared, and increased numbers of alpha-smooth muscle actin-positive cells were observed in the hybrid group. CONCLUSIONS Cell transplantation accelerated thrombus organization. Moreover, slow release of bFGF enhanced the effects of cell transplantation. Cell transplantation into unorganized spaces may improve the outcomes of endovascular treatments of aortic aneurysms.
Collapse
Affiliation(s)
- Masaki Kajimoto
- Department of Thoracic and Cardiovascular Surgery, Mie University, Graduate School of Medicine, 2-174, Edobashi, Tsu, Mie 514-8507, Japan
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Pitton MB, Schweitzer H, Herber S, Schmiedt W, Neufang A, Kalden P, Thelen M, Düber C. MRI versus helical CT for endoleak detection after endovascular aneurysm repair. AJR Am J Roentgenol 2006; 185:1275-81. [PMID: 16247149 DOI: 10.2214/ajr.04.0729] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The objective of our study was to investigate the diagnostic accuracy of MRI and helical CT for endoleak detection. SUBJECTS AND METHODS Fifty-two patients underwent endovascular aneurysm repair with nitinol stent-grafts. Follow-up data sets included contrast-enhanced biphasic CT and MRI within 48 hr after the intervention; at 3, 6, and 12 months; and yearly thereafter. The endoleak size was categorized as < or = 3%, > 3% < or = 10%, > 10% < or = 30%, or > 30% of the maximum cross-sectional aneurysm area. A consensus interpretation of CT and MRI was defined as the standard of reference. RESULTS Of 252 data sets, 141 showed evidence for endoleaks. The incidence of types I, II, and III endoleaks and complex endoleaks was 3.2%, 40.1%, 8.7%, and 4.0%, respectively. The sensitivity for endoleak detection was 92.9%, 44.0%, 34.8%, and 38.3% for MRI, biphasic CT, uniphasic arterial CT, and uniphasic late CT, respectively. The corresponding negative predictive values were 91.7%, 58.4%, 54.7%, and 56.1%, respectively. The overall accuracy of endoleak detection and correct sizing was 95.2%, 58.3%, 55.6%, and 57.1% for MRI, biphasic CT, uniphasic arterial CT, and uniphasic late CT, respectively. CONCLUSION MRI is significantly superior to biphasic CT for endoleak detection and rating of endoleak size, followed by uniphasic late and uniphasic arterial CT scans. MRI shows a significant number of endoleaks in cases with negative CT findings and may help illuminate the phenomenon of endotension. Endoleak rates reported after endovascular aneurysm repair substantially depend on the imaging techniques used.
Collapse
Affiliation(s)
- Michael B Pitton
- Department of Radiology, University Hospital of Mainz, Langenbeckstrasse 1, Mainz 55131, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Milner R, Ruurda JP, Blankensteijn JD. Durability and Validity of a Remote, Miniaturized Pressure Sensor in an Animal Model of Abdominal Aortic Aneurysm. J Endovasc Ther 2004; 11:372-7. [PMID: 15298503 DOI: 10.1583/04-1229.1] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE To investigate whether a remote, miniaturized pressure sensor could maintain calibration and function through organized thrombus over an extended period in a porcine model of abdominal aortic aneurysm (AAA). METHODS Six adult pigs had an AAA surgically created and excluded. A sensor zeroed to atmospheric pressure was placed within the aneurysm sac and another within the suprarenal aorta of each animal. Pressure measurements were taken at the initial operation and then on a weekly basis over 2 months. The aortic sensors were correlated to an intra-arterial pressure catheter at the initial operation and at the time of sacrifice. Back-table sensor correlation with atmospheric pressure was done at the time of explantation. RESULTS Three animals died during the follow-up period. Five animals were available for 6-week follow-up, of which 3 survived for the complete 8-week protocol. Two of the surviving animals had an intra-aortic sensor. All 5 aneurysm sac sensors functioned throughout the experimental period. At the time of sacrifice, the sacs contained a large amount of organized thrombus in which the sac sensors were deeply embedded. The 3 aortic sensors also functioned throughout the course of the experiments. The pressures correlated within 5 mmHg to the catheter-based measurements taken at the initial operation and at the time of sacrifice. Comparison to atmospheric pressure revealed no calibration offset in any sensor. CONCLUSIONS This chronic implantation study demonstrates the durability of a remote, miniaturized pressure sensor within a surgically created aneurysm sac as well as the suprarenal aorta of a porcine AAA model. There was no calibration offset in any of the sensors, and they remained valid at explantation. We believe that this is further evidence of the potential applicability of this sensor for clinical use.
Collapse
Affiliation(s)
- Ross Milner
- Division of Vascular Surgery, Emory University School of Medicine, Atlanta, Georgia 30322, USA.
| | | | | |
Collapse
|
15
|
Yamani MH, Starling RC, Cook DJ, Tuzcu EM, Abdo A, Paul P, Powell K, Ratliff NB, Yu Y, McCarthy PM, Young JB. Donor spontaneous intracerebral hemorrhage is associated with systemic activation of matrix metalloproteinase-2 and matrix metalloproteinase-9 and subsequent development of coronary vasculopathy in the heart transplant recipient. Circulation 2003; 108:1724-8. [PMID: 12975253 DOI: 10.1161/01.cir.0000087604.27270.5b] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND Matrix metalloproteinase (MMP)-2 and MMP-9 have been shown to play a role in the progression of hemorrhagic stroke. We hypothesized that donor intracerebral hemorrhage (ICH) is associated with activation of the metalloproteinases before transplantation that play a key role in the subsequent development of transplant vasculopathy. METHODS AND RESULTS We evaluated mRNA expressions of MMP-2 and MMP-9 in donor spleen lymphocytes (before transplantation) and in heart biopsies at 1 week after transplantation in 20 recipients from ICH donors and 20 recipients from trauma donors. Patients underwent serial coronary intravascular ultrasound, and interstitial myocardial fibrosis was quantified at 1 year. The baseline characteristics were similar except for increased donor age in the ICH group. Heart biopsies from the ICH group showed significant increased expression of MMP-2 (17-fold, P<0.0001) and MMP-9 (20-fold, P<0.0001) compared with the trauma group. Furthermore, the ICH group showed 1.8-fold (P=0.016) increased mRNA expression of MMP-2 and 1.7-fold (P=0.015) increased mRNA expression of MMP-9 in the donor spleen lymphocytes, suggesting the presence of systemic activation of metalloproteinases before transplantation. At 1 year, the ICH group showed increased myocardial fibrosis and accelerated coronary vasculopathy. Using multivariate regression analysis, MMP-9 was found to be associated with increased risk for vasculopathy independent of donor age (OR, 2.41; P=0.01; 95% CI, 1.24 to 4.69). CONCLUSIONS This is the first report to describe systemic activation of MMP-2 and MMP-9 in donors with intracerebral hemorrhage and subsequent development of allograft vasculopathy.
Collapse
Affiliation(s)
- Mohamad H Yamani
- Department of Cardiovascular Medicine, Kaufman Center for Heart Failure, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|