1
|
Pan Y, Varghese J, Tong MS, Yildiz VO, Azzu A, Gatehouse P, Wage R, Nielles-Vallespin S, Pennell DJ, Jin N, Bacher M, Hayes C, Speier P, Simonetti OP. Two-center validation of Pilot Tone based cardiac triggering of a comprehensive cardiovascular magnetic resonance examination. THE INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING 2024; 40:261-273. [PMID: 38082073 DOI: 10.1007/s10554-023-03002-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 10/31/2023] [Indexed: 12/26/2023]
Abstract
The electrocardiogram (ECG) signal is prone to distortions from gradient and radiofrequency interference and the magnetohydrodynamic effect during cardiovascular magnetic resonance imaging (CMR). Although Pilot Tone Cardiac (PTC) triggering has the potential to overcome these limitations, effectiveness across various CMR techniques has yet to be established. To evaluate the performance of PTC triggering in a comprehensive CMR exam. Fifteen volunteers and 20 patients were recruited at two centers. ECG triggered images were collected for comparison in a subset of sequences. The PTC trigger accuracy was evaluated against ECG in cine acquisitions. Two experienced readers scored image quality in PTC-triggered cine, late gadolinium enhancement (LGE), and T1- and T2-weighted dark-blood turbo spin echo (DB-TSE) images. Quantitative cardiac function, flow, and parametric mapping values obtained using PTC and ECG triggered sequences were compared. Breath-held segmented cine used for trigger timing analysis was collected in 15 volunteers and 14 patients. PTC calibration failed in three volunteers and one patient; ECG trigger recording failed in one patient. Out of 1987 total heartbeats, three mismatched trigger PTC-ECG pairs were found. Image quality scores showed no significant difference between PTC and ECG triggering. There was no significant difference found in quantitative measurements in volunteers. In patients, the only significant difference was found in post-contrast T1 (p = 0.04). ICC showed moderate to excellent agreement in all measurements. PTC performance was equivalent to ECG in terms of triggering consistency, image quality, and quantitative image measurements across multiple CMR applications.
Collapse
Affiliation(s)
- Yue Pan
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
- Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Juliet Varghese
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
- Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Matthew S Tong
- Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Vedat O Yildiz
- Center for Biostatistics, Department of Biomedical Informatics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Alessia Azzu
- Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, UK
| | - Peter Gatehouse
- Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, UK
| | - Rick Wage
- Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, UK
| | | | - Dudley J Pennell
- Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, UK
| | - Ning Jin
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Malvern, PA, USA
| | - Mario Bacher
- Siemens Healthineers AG, Erlangen, Germany
- Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | | | | | - Orlando P Simonetti
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
- Dorothy M. Davis Heart and Lung Research Institute, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
- Department of Internal Medicine, Division of Cardiovascular Medicine, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
- Department of Radiology, The Ohio State University Wexner Medical Center, Columbus, OH, USA.
| |
Collapse
|
2
|
Pan Y, Varghese J, Tong MS, Yildiz VO, Azzu A, Gatehouse P, Wage R, Nielles-Vallespin S, Pennell D, Jin N, Bacher M, Hayes C, Speier P, Simonetti OP. Two-center validation of Pilot Tone Based Cardiac Triggering of a Comprehensive Cardiovascular Magnetic Resonance Examination. RESEARCH SQUARE 2023:rs.3.rs-3121723. [PMID: 37461505 PMCID: PMC10350216 DOI: 10.21203/rs.3.rs-3121723/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
Background The electrocardiogram (ECG) signal is prone to distortions from gradient and radiofrequency interference and the magnetohydrodynamic effect during cardiovascular magnetic resonance imaging (CMR). Although Pilot Tone Cardiac (PTC) triggering has the potential to overcome these limitations, effectiveness across various CMR techniques has yet to be established. Purpose To evaluate the performance of PTC triggering in a comprehensive CMR exam. Methods Fifteen volunteers and twenty patients were recruited at two centers. ECG triggered images were collected for comparison in a subset of sequences. The PTC trigger accuracy was evaluated against ECG in cine acquisitions. Two experienced readers scored image quality in PTC-triggered cine, late gadolinium enhancement (LGE), and T1- and T2-weighted dark-blood turbo spin echo (DB-TSE) images. Quantitative cardiac function, flow, and parametric mapping values obtained using PTC and ECG triggered sequences were compared. Results Breath-held segmented cine used for trigger timing analysis was collected in 15 volunteers and 14 patients. PTC calibration failed in three volunteers and one patient; ECG trigger recording failed in one patient. Out of 1987 total heartbeats, three mismatched trigger PTC-ECG pairs were found. Image quality scores showed no significant difference between PTC and ECG triggering. There was no significant difference found in quantitative measurements in volunteers. In patients, the only significant difference was found in post-contrast T1 (p = 0.04). ICC showed moderate to excellent agreement in all measurements. Conclusion PTC performance was equivalent to ECG in terms of triggering consistency, image quality, and quantitative image measurements across multiple CMR applications.
Collapse
|
3
|
Sakaguchi E, Yamada A, Naruse H, Hattori H, Nishimura H, Kawai H, Muramatsu T, Ishii J, Hata T, Saito K, Izawa H. Long-term prognostic value of changes in left ventricular global longitudinal strain in patients with heart failure with preserved ejection fraction. Heart Vessels 2022; 38:645-652. [PMID: 36450933 DOI: 10.1007/s00380-022-02211-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 11/24/2022] [Indexed: 12/04/2022]
Abstract
BACKGROUND Left ventricular (LV) global longitudinal strain (GLS) has emerged as a more sensitive index than LV ejection fraction (LVEF) for detecting subclinical LV dysfunction. We examined whether changes in GLS values are associated with the long-term prognosis of patients with a preserved LVEF and acute decompensated heart failure (HF). METHODS We studied 100 consecutive patients (mean age: 71 years) who were hospitalized for HF with preserved ejection fraction (HFpEF) and had a preserved LVEF (≥ 50%) in both the acute and stable phases. We performed two-dimensional speckle-tracking echocardiography in the acute (GLS-acute) and stable (GLS-stable) phases at a median of 2 and 347 days after admission, respectively, and calculated the rate of change of the absolute value of GLS-stable with respect to that of GLS-acute. An improved GLS was defined as a rate of change in GLS ≥ 16%, and a non-improved GLS was a rate of change < 16%. The primary endpoint was the occurrence of major cardiovascular events (MACE). RESULTS During a mean follow-up period of 1218 days, MACE occurred in 26 patients, including 8 all-cause deaths and 18 readmissions for HF. The rate of change in GLS for patients with MACE was lower than compared to those without MACE (10.6% vs 26.0%, p < 0.001). Multivariate Cox regression analyses indicated the rate of change in GLS was an independent predictor of MACE (p < 0.001). A non-improved GLS was correlated with a high risk of MACE. CONCLUSION Changes in GLS values could be useful for the long-term risk stratification of patients hospitalized for HFpEF and persistently preserved LVEF.
Collapse
Affiliation(s)
- Eirin Sakaguchi
- Department of Faculty of Medical Technology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| | - Akira Yamada
- Department of Cardiology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan.
| | - Hiroyuki Naruse
- Department of Faculty of Medical Technology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| | - Hidekazu Hattori
- Department of Faculty of Medical Technology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| | - Hideto Nishimura
- Bantane Hospital, 3-6-10 Otoubashi, Nakagawa-Ku, Nagoya, Aichi, 454-8509, Japan
| | - Hideki Kawai
- Department of Cardiology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| | - Takashi Muramatsu
- Department of Cardiology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| | - Junnichi Ishii
- Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| | - Tadayoshi Hata
- Bantane Hospital, 3-6-10 Otoubashi, Nakagawa-Ku, Nagoya, Aichi, 454-8509, Japan
| | - Kuniaki Saito
- Department of Faculty of Medical Technology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| | - Hideo Izawa
- Department of Cardiology, Fujita Health University School of Medicine, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan
| |
Collapse
|
4
|
New algorithm to quantify cardiopulmonary interaction in patients with atrial fibrillation: a proof-of-concept study. Br J Anaesth 2020; 126:111-119. [PMID: 33138963 DOI: 10.1016/j.bja.2020.09.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 09/03/2020] [Accepted: 09/18/2020] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Traditional formulas to calculate pulse pressure variation (PPV) cannot be used in patients with atrial fibrillation (AF). We have developed a new algorithm that accounts for arrhythmia-induced pulse pressure changes, allowing us to isolate and quantify ventilation-induced pulse pressure variation (VPPV). The robustness of the algorithm was tested in patients subjected to altered loading conditions. We investigated whether changes in VPPV imposed by passive leg raising (PLR) were proportional to the pre-PLR values. METHODS Consenting patients with active AF scheduled for an ablation of the pulmonary vein under general anaesthesia and mechanical ventilation were included. Loading conditions were altered by PLR. ECG and invasive pressure data were acquired during 60 s periods before and after PLR. A generalised additive model was constructed for each patient on each observation period. The impact of AF was modelled on the two preceding RR intervals of each beat (RR0 and RR-1). The impact of ventilation and the long-term pulse pressure trends were modelled as separate splines. Ventilation-induced pulse pressure variation was defined as the percentage of the maximal change in pulse pressure during the ventilation cycle. RESULTS Nine patients were studied. The predictive abilities of the models had a median r2 of 0.92 (inter-quartile range: 89.2-94.2). Pre-PLR VPPV ranged from 0.1% to 27.9%. After PLR, VPPV decreased to 0-11.3% (P<0.014). The relation between the Pre-PLR values and the magnitude of the changes imposed by the PLR was statistically significant (P<0.001). CONCLUSIONS Our algorithm enables quantification of VPPV in patients with AF with the ability to detect changing loading conditions.
Collapse
|
5
|
Kong LY, Sun LL, Chen LL, Lv X, Liu F. Value of Index Beat in Evaluating Left Ventricular Systolic and Diastolic Function in Patients with Atrial Fibrillation: A Dual Pulsed-Wave Doppler Study. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:255-262. [PMID: 31784201 DOI: 10.1016/j.ultrasmedbio.2019.10.028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 10/03/2019] [Accepted: 10/30/2019] [Indexed: 06/10/2023]
Abstract
Atrial fibrillation (AF) poses challenges in use of the echocardiogram to assess left ventricular (LV) function. The index beat method has been found to agree well with the average method. We aimed to assess the value of the index beat method in evaluation of LV function using the dual pulsed wave Doppler technique. Peak early diastolic mitral inflow velocity (E) and diastolic (e') and systolic (s') mitral annulus velocity were simultaneously obtained and measured beat-to-beat in patients with AF. The index beat s' exhibited the best correlation (r = 0.96 and 0.92, respectively, for septal and lateral wall, both p values = 0.000) with the mean, while E/e' at the pre-index beat, rather than at the index beat-initiated cycle, had the best correlation with the mean (r = 0.88 for septal and 0.97 for lateral wall, both p values = 0.000).
Collapse
Affiliation(s)
- Ling-Yun Kong
- Cardiology Department, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University. Changping District, Beijing, China
| | - Lan-Lan Sun
- Echocardiography Department, Beijing Chao-Yang Hospital, Capital Medical University. Chaoyang District, Beijing, China
| | - Ling-Ling Chen
- Cardiology Department, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University. Changping District, Beijing, China
| | - Xiuzhang Lv
- Echocardiography Department, Beijing Chao-Yang Hospital, Capital Medical University. Chaoyang District, Beijing, China.
| | - Fang Liu
- Cardiology Department, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University. Changping District, Beijing, China
| |
Collapse
|
6
|
Martín A, Coll‐Vinent B, Suero C, Fernández‐Simón A, Sánchez J, Varona M, Cancio M, Sánchez S, Carbajosa J, Malagón F, Montull E, Arco C. Benefits of Rhythm Control and Rate Control in Recent-onset Atrial Fibrillation: The HERMES-AF Study. Acad Emerg Med 2019; 26:1034-1043. [PMID: 30703274 DOI: 10.1111/acem.13703] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 01/21/2019] [Accepted: 01/22/2019] [Indexed: 01/02/2023]
Abstract
BACKGROUND Although rhythm control has failed to demonstrate long-term benefits over rate control in longstanding episodes of atrial fibrillation (AF), there is little evidence concerning recent-onset ones. We analyzed the benefits of rhythm and rate control in terms of symptoms alleviation and need for hospital admission in patients with recent-onset AF. METHODS This was a multicenter, observational, cross-sectional study with prospective standardized data collection carried out in 124 emergency departments (EDs). Clinical variables, treatment effectiveness, and outcomes (control of symptoms, final disposition) were analyzed in stable patients with recent-onset AF consulting for AF-related symptoms. RESULTS Of 421 patients included, rhythm control was chosen in 352 patients (83.6%), a global effectiveness of 84%. Rate control was performed in 69 patients (16.4%) and was achieved in 67 (97%) of them. Control of symptoms was achieved in 396 (94.1%) patients and was associated with a heart rate after treatment ≤ 110 beats/min (odds ratio [OR] = 14.346, 95% confidence interval [CI] = 3.90 to 52.70, p < 0.001) and a rhythm control strategy (OR = 2.78, 95% CI = 1.02 to 7.61, p = 0.046). Sixty patients (14.2%) were admitted: discharge was associated with a rhythm control strategy (OR = 2.22, 95% CI = 1.20-4.60, p = 0.031) and admission was associated with a heart rate > 110 beats/min after treatment (OR = 29.71, 95% CI = 7.19 to 123.07, p < 0.001) and acute heart failure (OR = 9.45, 95% CI = 2.91 to 30.65, p < 0.001). CONCLUSION In our study, recent-onset AF patients in whom rhythm control was attempted in the ED had a high rate of symptoms' alleviation and a reduced rate of hospital admissions.
Collapse
Affiliation(s)
- Alfonso Martín
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital Universitario Severo Ochoa and Universidad Alfonso X Madrid
| | - Blanca Coll‐Vinent
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Department Unitat de Fibril·lació Auricular (UFA) Grup de Recerca “Urgències: processos i patologies” IDIBAPS, Hospital Universitari Clínic Barcelona
| | - Coral Suero
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital de la Axarquía Málaga
| | - Amparo Fernández‐Simón
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital Universitario Virgen del Rocío Sevilla
| | - Juan Sánchez
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Complejo Hospitalario Universitario Granada
| | - Mercedes Varona
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital de Basurto, Bilbao
| | - Manuel Cancio
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department, Hospital Donostia San Sebastián
| | - Susana Sánchez
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital Universitario Río Hortega Valladolid
| | - José Carbajosa
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital General Universitario Alicante
| | - Francisco Malagón
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital Universitario Torrejón Madrid
| | | | - Carmen Arco
- Arrhythmia Division Spanish Society of Emergency Medicine (SEMES) Madrid
- Emergency Department Hospital Universitario La Princesa and Universidad Autónoma Madrid Spain
| | | |
Collapse
|
7
|
Model-Based Quantification of Left Ventricular Diastolic Function in Critically Ill Patients with Atrial Fibrillation from Routine Data: A Feasibility Study. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2019; 2019:9682138. [PMID: 31223333 PMCID: PMC6541946 DOI: 10.1155/2019/9682138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2018] [Accepted: 03/17/2019] [Indexed: 12/16/2022]
Abstract
Introduction Left ventricular diastolic dysfunction (LVDD) and atrial fibrillation (AF) are connected by pathophysiology and prevalence. LVDD remains underdiagnosed in critically ill patients despite potentially significant therapeutic implications since direct measurement cannot be performed in routine care at the bedside, and echocardiographic assessment of LVDD in AF is impaired. We propose a novel approach that allows us to infer the diastolic stiffness, β, a key quantitative parameter of diastolic function, from standard monitoring data by solving the nonlinear, ill-posed inverse problem of parameter estimation for a previously described mechanistic, physiological model of diastolic filling. The beat-to-beat variability in AF offers an advantageous setting for this. Methods By employing a global optimization algorithm, β is inferred from a simple six parameter and an expanded seven parameter model of left ventricular filling. Optimization of all parameters was limited to the interval ]0, 400[ and initialized randomly on large intervals encompassing the support of the likelihood function. Routine ECG and arterial pressure recordings of 17 AF and 3 sinus rhythm (SR) patients from the PhysioNet MGH/MF Database were used as inputs. Results Estimation was successful in 15 of 17 AF patients, while in the 3 SR patients, no reliable estimation was possible. For both models, the inferred β (0.065 ± 0.044 ml−1 vs. 0.038 ± 0.033 ml−1 (p=0.02) simple vs. expanded) was compatible with the previously described (patho) physiological range. Aortic compliance, α, inferred from the expanded model (1.46 ± 1.50 ml/mmHg) also compared well with literature values. Conclusion The proposed approach successfully inferred β within the physiological range. This is the first report of an approach quantifying LVDF from routine monitoring data in critically ill AF patients. Provided future successful external validation, this approach may offer a tool for minimally invasive online monitoring of this crucial parameter.
Collapse
|
8
|
Abstract
Attempts have been made to assess and measure ventricular contractility in patients and whether it can be used to identify heart failure. Due to the assumption that if the contractility of all the muscle fibres in a heart were lower, could it be called heart failure? Early attempts involved the assumption of a model of muscle that had a contractile unit in series with an elastic element, but this was found to be incorrect. Further attempts applied the series elastic model but this model also proved challenging. However, one method has assessed changes in contractility in a given patient, in response to an intervention, but could not compare contractility in a patient with heart failure with a normal person. End-systolic pressure-volume (ESPV) is regarded as a more correct index of contractility and this method was used to confirm changes in contractility from beat to beat during AF, showing results that end-systolic volume varied and indicating a shift of ESPV from beat to beat. This review will discuss the difficulty in measurement, the complicated nature of myocardial fibre orientation and hypertrophy, and whether myocardial contractility failure precipitates increased global heart failure.
Collapse
Affiliation(s)
- Mark Im Noble
- Department of Medicine and Therapeutics, University of Aberdeen,Aberdeen, UK
| |
Collapse
|
9
|
Wyffels PAH, Van Heuverswyn F, De Hert S, Wouters PF. Dynamic filling parameters in patients with atrial fibrillation: differentiating rhythm induced from ventilation-induced variations in pulse pressure. Am J Physiol Heart Circ Physiol 2016; 310:H1194-200. [DOI: 10.1152/ajpheart.00712.2015] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/09/2015] [Accepted: 02/13/2016] [Indexed: 11/22/2022]
Abstract
In patients with sinus rhythm, the magnitude of mechanical ventilation (MV)-induced changes in pulse pressure (PP) is known to predict the effect of fluid loading on cardiac output. This approach, however, is not applicable in patients with atrial fibrillation (AF). We propose a method to isolate this effect of MV from the rhythm-induced chaotic changes in PP in patients with AF. In 10 patients undergoing pulmonary vein ablation for treatment of AF under general anesthesia, ECG and PP waveforms were analyzed during apnea (T1) and during MV at tidal volumes of 8 ml/kg (T2) and 12 ml/kg (T3), respectively. In a first step, three mathematical models were compared in their ability to predict individual PP at T1. The best-fitting model was then selected as the reference to quantify the effects of MV on PP in these patients. A local polynomial regression model based on two preceding RR intervals (LOC2) was found to be superior over the quadratic models to predict PP. LOC2 was therefore selected to quantify variations in PP induced by MV. During T2 and T3, magnitude of PP deviations was related with the amplitude of tidal volume [mean bias error (SD) of −5 (6) and −8 (7) mmHg for T2 and T3, respectively; P = 0.003 repeated-measures ANOVA]. We conclude that LOC2 most accurately predicted rhythm-induced variations in PP. MV-induced deviations in PP can be quantified and may therefore provide a method to study cardiopulmonary interactions in the presence of arrhythmia.
Collapse
Affiliation(s)
- Piet A. H. Wyffels
- Department of Anesthesiology, Ghent University Hospital, Ghent, Belgium; and
| | | | - Stefan De Hert
- Department of Anesthesiology, Ghent University Hospital, Ghent, Belgium; and
| | - Patrick F. Wouters
- Department of Anesthesiology, Ghent University Hospital, Ghent, Belgium; and
| |
Collapse
|
10
|
2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol 2014; 64:e1-76. [PMID: 24685669 DOI: 10.1016/j.jacc.2014.03.022] [Citation(s) in RCA: 2879] [Impact Index Per Article: 287.9] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
11
|
Sadeghpour A, Hoghooghi A, Alizadehsani Z, Rezaei M, Aghapour S, Haghjoo M. Single beat determination of intraventricular systolic dyssynchrony in patients with atrial fibrillation and systolic dysfunction. Res Cardiovasc Med 2013; 2:85-9. [PMID: 25478499 PMCID: PMC4253764 DOI: 10.5812/cardiovascmed.8776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2012] [Revised: 12/09/2012] [Accepted: 12/19/2012] [Indexed: 11/16/2022] Open
Abstract
Background: Atrial fibrillation (AF) is the most common clinically significant cardiac arrhythmia. However, diagnosis of intraventricular dyssynchrony in patients with AF is difficult due to beat-to-beat variation. Additionally, evaluation of mechanical dyssynchrony in the traditional method is based on average of 5 to 10 beats, which is exhausting and time consuming. Single-beat evaluation of a beat with equal subsequent cardiac cycles has been proposed as an accurate method in patients with AF. Objectives: We proposed to evaluate intraventricular mechanical dyssynchrony by measuring time-to-peak systolic velocity between basolateral and basoseptal segments (septum to lateral wall delay) using Tissue Doppler Study (TDI) by two different methods. Materials and Methods: 31 patient (68 ± 10.3 years) with heart failure (EF < 35%) and AF rhythm, R-R cycle length more than 500 msec were evaluated. We found a target beat in which preceding R-R (R-R1) to pre-preceding R-R (R-R2) ratio was 1(RR1/RR2 = 1) then measured the intraventricular dyssynchrony in that cycle. Intraventricular dyssynchrony was also determined and averaged for 8 consecutive cardiac cycles. The values at RR1/RR2 = 1 were compared with the average of intraventricular dyssynchrony in eight cycles and the relationship between dyssynchrony were evaluated by paired T-test, linear Pearson correlation (r2), linear regression analysis. Results: The average of dyssynchrony in eight cycles showed a positive correlation with dyssynchrony in target beat RR1/RR2 = 1. Average of dyssynchrony in target beat was 46.77 msec, and average of 8 cycle was = 47.701, (P value = 0.776, Pearson linear correlation 0.769). Conclusions: Measurement of intraventricular dyssynchromy in basoseptal and basolateral segments in AF and heart failure patients in a single beat with RR1/RR2 = 1 , were very similar to the average value of eight cardiac cycle.
Collapse
Affiliation(s)
- Anita Sadeghpour
- Echocardiography Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University of Medical Sciences, Tehran, IR Iran
| | - Alireza Hoghooghi
- Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University Medical Science, Tehran, IR Iran
| | - Zahra Alizadehsani
- Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University Medical Science, Tehran, IR Iran
| | - Mohsen Rezaei
- Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University Medical Science, Tehran, IR Iran
| | - Sevil Aghapour
- Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Tehran University Medical Science, Tehran, IR Iran
| | - Majid Haghjoo
- Rajaie Cardiovascular Medical and Research Center, Tehran University of Medical Sciences, Tehran, IR Iran
- Corresponding author: Majid Haghjoo, Cardiac Electrophysiology Research Center, Rajaie Cardiovascular Medical and Research Center, Vali-Asr Ave, Niayesh Blvd, Tehran, IR Iran, Tel: +98-2123922163, Fax: +98-2122048174, E-mail:
| |
Collapse
|
12
|
Relationship between 24-h Holter recordings and clinical outcomes in patients with permanent atrial fibrillation. J Cardiol 2012; 60:42-6. [DOI: 10.1016/j.jjcc.2012.02.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 02/08/2012] [Accepted: 02/09/2012] [Indexed: 11/19/2022]
|
13
|
Marqué S, Launey Y. Traitement de la fibrillation atriale en réanimation (hors anticoagulation). MEDECINE INTENSIVE REANIMATION 2012. [DOI: 10.1007/s13546-012-0454-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
14
|
Su HM, Lin TH, Hsu PC, Chu CY, Lee WH, Lee CS, Lai WT, Sheu SH, Voon WC. Myocardial performance index derived from preejection period: a novel and feasible parameter in evaluation of cardiac performance in patients with permanent atrial fibrillation. Echocardiography 2011; 28:1081-7. [PMID: 22077881 DOI: 10.1111/j.1540-8175.2011.01491.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Using tissue Doppler echocardiography, we can measure preejection period (PEPa), defined as the interval measured from the onset of QRS to the onset of the systolic mitral annular velocity pattern, isovolumic relaxation time (IVRTa), defined as the interval measured from the end of systolic mitral annular velocity pattern to the onset of diastolic mitral annular velocity pattern, and ejection time (ETa), defined as the interval measured from the onset to the end of systolic mitral annular velocity pattern on the same cardiac cycle. The aim of this study is to test the applicability of PEPa-derived myocardial performance index (MPI), defined as the ratio of PEPa + IVRTa to ETa, as an indicator of combined left ventricular systolic and diastolic function in patients with permanent atrial fibrillation. METHODS Echocardiographic examination was performed in 54 consecutive patients with permanent atrial fibrillation. Clinical and echocardiographic parameters were compared and analyzed. RESULTS After a multivariate analysis, the average RR interval on the tissue Doppler image (β=-0.328, P = 0.002), left ventricular ejection fraction (β=-0.260, P = 0.024), and early diastolic mitral annular velocity (β=-0.408, P < 0.001) were the major determinants of PEPa-derived MPI. CONCLUSIONS PEPa-derived MPI had a significant correlation with echocardiographic left ventricular diastolic and systolic function. It may be a novel and feasible indicator in assessment of global left ventricular function in patients with permanent atrial fibrillation.
Collapse
Affiliation(s)
- Ho-Ming Su
- Division of Cardiology, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Fuster V, Rydén LE, Cannom DS, Crijns HJ, Curtis AB, Ellenbogen KA, Halperin JL, Kay GN, Le Huezey JY, Lowe JE, Olsson SB, Prystowsky EN, Tamargo JL, Wann LS. 2011 ACCF/AHA/HRS Focused Updates Incorporated Into the ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation. J Am Coll Cardiol 2011; 57:e101-98. [PMID: 21392637 DOI: 10.1016/j.jacc.2010.09.013] [Citation(s) in RCA: 642] [Impact Index Per Article: 49.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
16
|
Shahgaldi K, Manouras A, Abrahamsson A, Gudmundsson P, Brodin LA, Winter R. Three-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation. Cardiovasc Ultrasound 2010; 8:45. [PMID: 20920373 PMCID: PMC2972240 DOI: 10.1186/1476-7120-8-45] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2010] [Accepted: 10/05/2010] [Indexed: 05/26/2023] Open
Abstract
Background Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching artifact. The study aimed to investigate whether SB full volume 3DE acquisition reduces inter- and intraobserver variability in assessment of LV volumes and EF in comparison to four-beat (4B) ECG-gated full volume 3DE recording in patients with AF. Methods A total of 78 patients were included in this study. Fifty-five with sinus rhythm (group A) and 23 having AF (group B). 4B and SB 3DE was performed in all patients. LV volumes and EF was determined by these two modalities and inter- and intraobserver variability was analyzed. Results SB modality showed significantly lower inter- and intraobserver variability in group B in comparison to 4B when measuring LV volumes and EF, except for end-systolic volume (ESV) in intraobserver analysis. There were significant differences when calculating the LV volumes (p < 0.001) and EF (p < 0.05) with SB in comparison to 4B in group B. Conclusion Single-beat three-dimensional full volume acquisition seems to be superior to four-beat ECG-gated acquisition in measuring left ventricular volumes and ejection fraction in patients having atrial fibrillation. The variability is significantly lower both for ejection fraction and left ventricular volumes.
Collapse
Affiliation(s)
- Kambiz Shahgaldi
- Department of Cardiology, Karolinska University Hospital Huddinge, Stockholm, Sweden.
| | | | | | | | | | | |
Collapse
|
17
|
Pizzale S, Lemery R, Green MS, Gollob MH, Tang ASL, Birnie DH. Frequency and predictors of tachycardia-induced cardiomyopathy in patients with persistent atrial flutter. Can J Cardiol 2009; 25:469-72. [PMID: 19668781 DOI: 10.1016/s0828-282x(09)70119-9] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
BACKGROUND There are few data on the frequency and predictors of tachycardia-induced cardiomyopathy (TICM) in patients with persistent atrial flutter. OBJECTIVES To examine the incidence of TICM in patients undergoing ablation for persistent atrial flutter, and to examine predictors for the development of TICM. METHODS AND RESULTS One hundred eleven patients met the inclusion criteria for the present study. Twenty-eight of 111 (25%) patients had cardiomyopathy before ablation. Sixteen of 28 (57%) patients showed significant improvement in their left ventricular (LV) function postablation. LV function improved to normal in 12 of 16 (75%) patients. Nineteen of 28 (68%) cardiomyopathy patients had preablation LV function in the range in which they would be considered for an implantable cardioverter defibrillator for primary prevention of sudden cardiac death. In nine of 19 (47%) patients, the ejection fraction improved such that an implantable cardioverter defibrillator was no longer indicated. In multivariate analysis, average ventricular rate during atrial flutter was the only independent predictor of reversibility of cardiomyopathy (P=0.013). CONCLUSIONS Sixteen of 28 (57%) cardiomyopathy patients with persistent atrial flutter had significantly improved LV function postablation. In 75% of these patients, LV function improved to normal.
Collapse
Affiliation(s)
- Stephen Pizzale
- University of Ottawa Heart Institute, Ottawa, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
18
|
Shimizu J, Mohri S, Ito H, Takaki M, Suga H. Mode of frequency distribution of external work efficiency of arrhythmic beats during atrial fibrillation remains normal in canine heart. J Physiol Sci 2009; 59:75-80. [PMID: 19340564 PMCID: PMC10717949 DOI: 10.1007/s12576-008-0007-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2008] [Accepted: 11/05/2008] [Indexed: 10/20/2022]
Abstract
The external work (EW) efficiency of individual arrhythmic beats of the left ventricle (LV) cannot directly be obtained since LV O(2) consumption (VO(2)) of each beat cannot directly be measured under beat-to-beat varying contractile and loading conditions. We, however, have recently reported that VO(2) of each arrhythmic beat can reasonably be estimated by VO(2) = aPVA + bE(max) + c even under varying PVA and E(max). Here, PVA is the LV pressure-volume (P-V) area as a measure of the LV total mechanical energy, E(max) is the LV end-systolic elastance as an index of the LV contractility, a is a constant O(2) cost of PVA, b is a constant O(2) cost of E(max), and c is the basal metabolic VO(2) of the beat, all on a per-beat basis. Using the above formula in this study, we calculated VO(2) of the individual arrhythmic beats from their measured PVA and E(max) during electrically induced atrial fibrillation (AF) in normal canine hearts. We then calculated their LV EW efficiency by dividing their measured EW with the estimated VO(2). We found that the thus calculated EW efficiency of the arrhythmic beats had a rightward skewed distribution with a mode of 15% and a maximum of 18% around a mean of 13% on average in six hearts. This mode remained comparable to the efficiency (15%) at regular tachycardia though 22% lower than mean arrhythmic tachycardia.
Collapse
Affiliation(s)
- Juichiro Shimizu
- Department of Physiology II, Nara Medical University, Kashihara, Nara, 634-8521, Japan.
| | | | | | | | | |
Collapse
|
19
|
Rajagopal K, Bridges C, Rajagopal KR. Towards an understanding of the mechanics underlying aortic dissection. Biomech Model Mechanobiol 2007; 6:345-59. [PMID: 17356838 DOI: 10.1007/s10237-006-0069-3] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2005] [Accepted: 12/01/2006] [Indexed: 10/23/2022]
Abstract
Acute aortic dissection and associated aortic catastrophes are among the most devastating forms of cardiovascular disease, with a remarkably high morbidity and mortality despite current medical and surgical treatment. The mechanics underlying aortic dissection are incompletely understood, and a further understanding of the relevant fluid and solid mechanics may yield not only a better appreciation of its pathogenesis, but also the development of improved diagnostic and therapeutic strategies. After illustrating some of the inadequacies with respect to the extant work on the mechanics of aortic dissection, we alternatively postulate that the clinical hemodynamic disturbances that render the aorta susceptible to the initiation of dissection are principally elevated maximum systolic and mean aortic blood pressure, whereas the hemodynamic disturbances that facilitate propagation of dissection are principally elevated pulse pressure and heart rate. Furthermore, abnormal aortic mechanical properties and/or geometry are requisite for dissection to occur. Specifically, we propose that the degree of anisotropy will directly influence the probability of future aortic dissection. Imaging of the aorta may provide information regarding aortic anisotropy and geometry, and in combination with a hemodynamic risk assessment, has the potential to be able to prospectively identify patients at high risk for future aortic dissection thereby facilitating prophylactic intervention. The aim of the paper is to identify the main mechanical issues that have a bearing on aortic dissection, and to suggest an appropriate mathematical model for describing the problem.
Collapse
|
20
|
Fuster V, Rydén LE, Cannom DS, Crijns HJ, Curtis AB, Ellenbogen KA, Halperin JL, Le Heuzey JY, Kay GN, Lowe JE, Olsson SB, Prystowsky EN, Tamargo JL, Wann S. ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation-executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Revise the 2001 Guidelines for the Management of Patients with Atrial Fibrillation). Eur Heart J 2007; 27:1979-2030. [PMID: 16885201 DOI: 10.1093/eurheartj/ehl176] [Citation(s) in RCA: 362] [Impact Index Per Article: 21.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
21
|
Asirvatham SJ. Tachycardia-Induced Cardiomyopathy, Without the Tachycardia: Yet Another Reason to Ablate Atrial Fibrillation! J Cardiovasc Electrophysiol 2007; 18:15-7. [PMID: 17240546 DOI: 10.1111/j.1540-8167.2006.00694.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
22
|
Ciaramitaro G, Sgarito G, Solimene F, Maglia G, Vicentini A, DI Donato G, Raciti G, Parrinello G, Del Giudice GB. Role of rate control and regularization through pacing in patients with chronic atrial fibrillation and preserved ventricular function: the VRR study. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2006; 29:866-74. [PMID: 16923003 DOI: 10.1111/j.1540-8159.2006.00453.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
AIM High heart rates in chronic atrial fibrillation (CAF) is one of the factors responsible for hemodynamic alterations and may lead to tachycardiomyopathies. The ventricular rate regulation (VRR) study evaluates the effect of ventricular rate regularization in CAF patients with preserved ventricular function, marked ventricular rate variability, and indications for pacemaker (PM) implantation owing to symptomatic pauses. Rate regularization was achieved using VRR algorithm (INSIGNIA pacemakers, Guidant Corp., St. Paul, MN, USA). METHODS One month after PM implantation, 58 patients followed two 3-month crossover periods (VRR-OFF; VRR-ON) in which the VRR algorithm was randomized and compared to fixed rate stimulation at 60 ppm. During follow-up visits a 6-minute walk test was performed under partially inhibited conditions (PM at 40 ppm) and ventricular response was recorded. The following parameters were measured: mean ventricular rate (MR), rate variability (RR30), rate recovery after exercise (SLOPE = (R-END - R-REC)/(R-END - 40)), R-END being the rate at end of walk and R-REC the rate 1 minute after exercise. RESULTS The VRR algorithm decreased rate variability (RR30: -7.36 +/- 8.8; P < 0.01) without increasing ventricular rate (MR: -1.11 +/- 8.3 P = NS), while SLOPE improved significantly (SLOPE: +15.41 +/- 16.8 P < 0.01). CONCLUSIONS VRR effectively stabilizes rate, without increasing pacing rate above spontaneous rhythm and helps achieve a more favorable autonomic balance, improving rate recovery after exercise.
Collapse
|
23
|
ACC/AHA/ESC: Guías de Práctica Clínica 2006 para el manejo de pacientes con fibrilación auricular. Versión resumida. Rev Esp Cardiol 2006. [DOI: 10.1157/13096583] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
24
|
Yamanaka-Funabiki K, Onishi K, Tanabe M, Dohi K, Ito M, Ohte N, Nobori T, Nakano T. Single Beat Determination of Regional Myocardial Strain Measurements in Patients with Atrial Fibrillation. J Am Soc Echocardiogr 2006; 19:1332-7. [PMID: 17098135 DOI: 10.1016/j.echo.2006.05.026] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2005] [Indexed: 11/23/2022]
Abstract
Atrial fibrillation (AF) and congestive heart failure share several features and often coexist in the same patients; therefore, serial assessment of regional myocardial function is important for patients with AF. However, the clinical assessment of regional myocardial function in AF is unreliable and difficult because of beat-to-beat variation. Recent reports have shown that the ratio of the preceding to the prepreceding R-R interval (RR1/RR2) can be used to assess global left ventricular systolic function. Accordingly, we tested the hypothesis that regional wall motion can be estimated from a single beat based on RR1/RR2 in patients with AF. Peak systolic strain at basal, mid, and apical segments of the septal wall was measured by Doppler tissue imaging from an apical 4-chamber view for 30 seconds in 50 patients with AF (mean ejection fraction 52.1 +/- 15.3%; mean heart rate 76.4 +/- 16.0/min). There was a positive linear relationship between peak strain and RR1/RR2 and RR1, and a negative relationship with RR2, with the correlation of peak strain to RR1/RR2 was better than that in RR1 or RR2. Furthermore, peak strain at RR1/RR2 = 1 was calculated from the linear regression and compared with the average measured value of all recorded cardiac cycles in each patient. In all cases, average peak strain showed a significant positive correlation with RR1/RR2 at each segment (r = 0.99). In conclusion, regional myocardial strain at RR1/RR2 = 1 on the linear regression represents the average value of all recorded cardiac cycles in patients with AF.
Collapse
|
25
|
Fuster V, Rydén LE, Cannom DS, Crijns HJ, Curtis AB, Ellenbogen KA, Halperin JL, Le Heuzey JY, Kay GN, Lowe JE, Olsson SB, Prystowsky EN, Tamargo JL, Wann S, Smith SC, Jacobs AK, Adams CD, Anderson JL, Antman EM, Hunt SA, Nishimura R, Ornato JP, Page RL, Riegel B, Priori SG, Blanc JJ, Budaj A, Camm AJ, Dean V, Deckers JW, Despres C, Dickstein K, Lekakis J, McGregor K, Metra M, Morais J, Osterspey A, Zamorano JL. ACC/AHA/ESC 2006 Guidelines for the Management of Patients With Atrial Fibrillation—Executive Summary. J Am Coll Cardiol 2006; 48:854-906. [PMID: 16904574 DOI: 10.1016/j.jacc.2006.07.009] [Citation(s) in RCA: 717] [Impact Index Per Article: 39.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
26
|
|
27
|
Vandenberghe S, Segers P, Steendijk P, Meyns B, Dion RAE, Antaki JF, Verdonck P. Modeling ventricular function during cardiac assist: does time-varying elastance work? ASAIO J 2006; 52:4-8. [PMID: 16436883 DOI: 10.1097/01.mat.0000196525.56523.b8] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The time-varying elastance theory of Suga et al. is widely used to simulate left ventricular function in mathematical models and in contemporary in vitro models. We investigated the validity of this theory in the presence of a left ventricular assist device. Left ventricular pressure and volume data are presented that demonstrate the heart-device interaction for a positive-displacement pump (Novacor) and a rotary blood pump (Medos). The Novacor was implanted in a calf and used in fixed-rate mode (85 BPM), whereas the Medos was used at several flow levels (0-3 l/min) in seven healthy sheep. The Novacor data display high beat-to-beat variations in the amplitude of the elastance curve, and the normalized curves deviate strongly from the typical bovine curve. The Medos data show how the maximum elastance depends on the pump flow level. We conclude that the original time-varying elastance theory insufficiently models the complex hemodynamic behavior of a left ventricle that is mechanically assisted, and that there is need for an updated ventricular model to simulate the heart-device interaction.
Collapse
|
28
|
Wang CL, Lin KH, Luqman N, Ho WJ, Hsu LA, Chu PH, Kuo CT. Refinement on single-beat determination of left ventricular systolic function in patients with atrial fibrillation. J Am Soc Echocardiogr 2006; 18:913-8. [PMID: 16153513 DOI: 10.1016/j.echo.2005.03.001] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/23/2004] [Indexed: 10/25/2022]
Abstract
Single-beat determination of left ventricular systolic function at a beat with equal subsequent cardiac cycles has been proposed as an accurate method in atrial fibrillation. However, there has still been substantial variability between the values calculated from beats with equal subsequent cycles. Therefore, some refinement on the single-beat method is needed. In 100 patients with atrial fibrillation, Doppler aortic flow time-velocity integral was determined for at least 20 consecutive cardiac cycles. The values at beats with equal subsequent cardiac cycles were chosen and compared with the average values over all cardiac cycles. The values at beats with cycle lengths shorter than 500 milliseconds were usually far below the average values over all cardiac cycles. Bland-Altman agreement analysis revealed improved accuracy by gradually narrowing the range of the limits of agreement when 2 or 3 beats with equal subsequent cycles and cycle lengths longer than 500 milliseconds were used for evaluation.
Collapse
Affiliation(s)
- Chun-Li Wang
- Department of Cardiology, Chang Gung Memorial Hospital, Taipei, Taiwan
| | | | | | | | | | | | | |
Collapse
|
29
|
Tanabe M, Onishi K, Dohi K, Kitamura T, Ito M, Nobori T, Nakano T. Assessment of left ventricular systolic function in patients with chronic atrial fibrillation and dilated cardiomyopathy using the ratio of preceding to prepreceding R–R intervals. Int J Cardiol 2006; 108:197-201. [PMID: 15936095 DOI: 10.1016/j.ijcard.2005.05.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2004] [Revised: 03/25/2005] [Accepted: 05/04/2005] [Indexed: 11/28/2022]
Abstract
The objective of this study was to determine the relation between left ventricular (LV) systolic function and the ratio of preceding (RR1) to prepreceding (RR2) R-R intervals in patients with chronic atrial fibrillation (AF) and dilated cardiomyopathy. LV systolic function (Emax) was examined using a conductance catheter with a micromanometer in 13 patients with chronic AF and dilated cardiomyopathy. We calculated Emax as a load-independent index of LV contractility and compared it with RR1, RR2, and the ratio of RR1/RR2. We analyzed 50+/-13 cardiac cycles (range 18-61) in each patient. Average heart rate was 80+/-13 beats/min, and ejection fraction over all cardiac cycle in each patient measured by conductance catheter was 31+/-8%. Emax was positively correlated with RR1 and RR1/RR2 in all patients, and negatively correlated with RR2 in all patients. In each patient, correlation coefficients of Emax with RR1/RR2 were greater than those with either RR1 or RR2. Furthermore, Emax at RR1/RR2=1 in the linear regression line reflected average Emax over all cardiac cycles in each patient. In conclusion, we have shown that LV contractility correlated positively with RR1/RR2 in patients with chronic AF and dilated cardiomyopathy, and LV contractility at RR1/RR2=1 represents the average value of contractility over all cardiac cycles.
Collapse
Affiliation(s)
- Masaki Tanabe
- The First Department of Internal Medicine, Mie University School of Medicine, Tsu, Japan
| | | | | | | | | | | | | |
Collapse
|
30
|
Wang CL, Ho WJ, Luqman N, Hsu LA, Kuo CT. Biplane assessment of left ventricular function during atrial fibrillation at beats with equal subsequent cycles. Int J Cardiol 2005; 113:54-60. [PMID: 16352354 DOI: 10.1016/j.ijcard.2005.10.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Revised: 09/14/2005] [Accepted: 10/28/2005] [Indexed: 10/25/2022]
Abstract
BACKGROUND Prior study has demonstrated that the biplane single-beat method could be used to assess left ventricular function during atrial fibrillation at a beat with equal subsequent cycles. The study was to test whether we could improve the method by measuring a few beats with equal subsequent cycles and cycle-length limits. METHODS In 75 patients with atrial fibrillation, stroke volume and ejection fraction were determined from simultaneous biplane views of left ventricle for 20 beats using a matrix-array transducer and a biplane Simpson's rule. The influence of cycle lengths on the values of systolic parameters at beats with equal subsequent cycles was examined from the plot of normalized parameters (measured values/average values) against cycle lengths. The values of 1 to 3 beats with equal subsequent cycles and cycle-length limits were averaged and compared with the average values over 20 beats by Bland-Altman and mean percentage difference analysis. The variability of repeat measurements was evaluated in 10 patients. RESULTS The systolic parameters measured at beats with cycle lengths shorter than 500 ms were usually far below the average values. Agreement and mean percentage difference analysis revealed improved accuracy when 2 or 3 beats with cycle-length limits (>500 ms) were used for assessment. As the variability of averaging 2 or 3 beats is no greater than that of repeat measurements, both methods are equally good. CONCLUSIONS Accurate assessment of left ventricular systolic function in atrial fibrillation can be obtained by averaging 2 beats with equal subsequent cycles and cycle-length limits (>500 ms).
Collapse
Affiliation(s)
- Chun-Li Wang
- The Department of Cardiology, Chang Gung Memorial Hospital, No. 199, Tunhwa N. Road, Taipei, Taiwan
| | | | | | | | | |
Collapse
|
31
|
Mohri S, Shimizu J, Ito H, Yamaguchi H, Sano S, Takaki M, Suga H. Variable Unstressed Volume Keeps Normal Distributions of Canine Left Ventricular Contractility and Total Mechanical Energy under Atrial Fibrillation. ACTA ACUST UNITED AC 2005; 55:255-64. [PMID: 16255844 DOI: 10.2170/jjphysiol.rp000405] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2005] [Accepted: 10/27/2005] [Indexed: 11/05/2022]
Abstract
We have reported that the contractility index (E(max)) and the total mechanical energy (PVA) of arrhythmic beats of the left ventricle (LV) distribute normally in canine hearts under electrically induced atrial fibrillation (AF). Here, E(max) is the ventricular elastance as the slope of the end-systolic (ES) pressure-volume (P-V) relation (ESPVR), and PVA is the systolic P-V area as the sum of the external mechanical work within the P-V loop and the elastic potential energy under the ESPVR. To obtain E(max) and PVA, we had to assume the systolic unstressed volume (V(o)) as the V-axis intercept of the ESPVR to be constant despite the varying E(max), since there was no method to obtain V(o) directly in each arrhythmic beat. However, we know that in regular stable beats V(o) decreases by approximately 7 ml/100 g LV with approximately 100 times the increases in E(max) from ~0.2 mmHg/(ml/100 g LV) of almost arresting weak beats to approximately 20 mmHg/(ml/100 g LV) of strong beats with a highly enhanced contractility. In the present study, we investigated whether E(max) and PVA under AF could still distribute normally, despite such E(max)-dependent V(o) changes. The present analyses showed that the E(max) changes were only approximately 3 times at most from the weakest to the strongest arrhythmic beat under AF. These changes were not large enough to affect V(o) enough to distort the frequency distributions of E(max) and PVA from normality. We conclude that one could practically ignore the slight E(max) and PVA changes with the Emax-dependent V(o) changes under AF.
Collapse
Affiliation(s)
- Satoshi Mohri
- Department of Cardiovascular Physiology, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Shikatacho, Okayama, 700-8558 Japan.
| | | | | | | | | | | | | |
Collapse
|
32
|
Popović ZB, Yamada H, Mowrey KA, Zhang Y, Wallick DW, Grimm RA, Thomas JD, Mazgalev TN. Frank-Starling mechanism contributes modestly to ventricular performance during atrial fibrillation. Heart Rhythm 2005; 1:482-9. [PMID: 15851203 DOI: 10.1016/j.hrthm.2004.06.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2004] [Accepted: 06/29/2004] [Indexed: 11/15/2022]
Abstract
OBJECTIVES The aim of this study was to assess whether Frank-Starling mechanism has an independent effect on left ventricular (LV) performance in atrial fibrillation (AF). BACKGROUND Ventricular performance in AF depends on variable contractility through the interval-force mechanism based on the ratio of preceding and pre-preceding RR intervals (RR(p)/RR(pp)). The impact of end-diastolic volume (EDV) variability, through the Frank-Starling mechanism, is not well understood. METHODS We induced AF in 16 open chest dogs. RR intervals, LV pressure, LV volume, and aortic flow were collected for >400 beats during rapid AF (ventricular cycle length 292 +/- 66 ms). In six of the dogs, additional data were collected while average ventricular cycle length was prolonged from 258 +/- 34 ms to 445 +/- 80 ms by selective vagal nerve stimulation of the AV node. RESULTS The relations of maximal LV power (LVPower) and peak LV pressure derivative (dP/dt) versus RR(p)/RR(pp) were fitted to the equation y = A * (1 - EXP (RR(p)/RR(pp)min - RR(p)/RR(pp))/C) and the residuals (RES) of these relations were analyzed. LVPower and dP/dt strongly correlated with RR(p)/RR(pp) (r(2) = 0.67 +/- 0.12 and 0.66 +/- 0.12, P < .0001 for all correlations). Importantly, RES-LVPower and RES-dP/dt showed linear correlation with EDV (r(2) = 0.20 +/- 0.14 and r(2) = 0.24 +/- 0.17, P < .01 for all correlations). In the six dogs with slowed average ventricular rate, the slope of both residual relationships (RES-LVPower vs EDV and RES- dP/dt vs EDV) decreased (P < .03 for both). CONCLUSIONS The Frank-Starling mechanism contributes to ventricular performance in AF independently of the interval-force effects of the beat-to-beat variability in cardiac contractility. The Frank-Starling mechanism is sensitive to the average ventricular rate.
Collapse
Affiliation(s)
- Zoran B Popović
- Department of Cardiovascular Medicine, The Cleveland Clinic Foundation, Ohio 44195, USA
| | | | | | | | | | | | | | | |
Collapse
|
33
|
Mohri S, Shimizu J, Iribe G, Ito H, Morita T, Yamaguchi H, Sano S, Kajiya F, Suga H. Normal distribution of ventricular pressure-volume area of arrhythmic beats under atrial fibrillation in canine heart. Am J Physiol Heart Circ Physiol 2005; 288:H1740-6. [PMID: 15550527 DOI: 10.1152/ajpheart.00584.2004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We previously found the frequency distribution of the left ventricular (LV) effective afterload elastance (Ea) of arrhythmic beats to be nonnormal or non-Gaussian in contrast to the normal distribution of the LV end-systolic elastance (Emax) in canine in situ LVs during electrically induced atrial fibrillation (AF). These two mechanical variables determine the total mechanical energy [systolic pressure-volume area (PVA)] generated by LV contraction when the LV end-diastolic volume is given on a per-beat basis. PVA and Emax are the two key determinants of the LV O2 consumption per beat. In the present study, we analyzed the frequency distribution of PVA during AF by its χ2, significance level, skewness, and kurtosis and compared them with those of other major cardiodynamic variables including Ea and Emax. We assumed the volume intercept (V0) of the end-systolic pressure-volume relation needed for Emax determination to be stable during arrhythmia. We found that PVA distributed much more normally than Ea and slightly more so than Emax during AF. We compared the χ2, significance level, skewness, and kurtosis of all the complex terms of the PVA formula. We found that the complexity of the PVA formula attenuated the effect of the considerably nonnormal distribution of Ea on the distribution of PVA along the central limit theorem. We conclude that mean (SD) of PVA can reliably characterize the distribution of PVA of arrhythmic beats during AF, at least in canine hearts.
Collapse
Affiliation(s)
- Satoshi Mohri
- Dept. of Cardiovascular Physiology, Okayama University Graduate School of Medicine and Dentistry, 2-5-1 Shikatacho, Okayama 700-8558, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Ko HS, Kim CJ, Ryu WS. New parameters for left ventricular function in atrial fibrillation: based on the relationship between RR interval and performance. J Korean Med Sci 2005; 20:20-5. [PMID: 15716596 PMCID: PMC2808569 DOI: 10.3346/jkms.2005.20.1.20] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study was designed to obtain new parameters representing left ventricular (LV) function independent of irregular RR intervals in atrial fibrillation (AF). AF patients were divided into Normal (n=9) and LV Dysfunction (n=9) groups. The relations between LV outflow peak ejection velocity (Vpe) and preceding (RR-1) or prepreceding RR intervals (RR-2) were obtained using logarithmic equations, from which the squared correlation coefficient (r2), slope, Vpe at RR-1 or RR-2=1 sec (Vpe-1), and the ratio of slope to Vpe-1 (Slope/Vpe-1) were calculated. Among the parameters between RR-1 and Vpe, Slope/Vpe-1 was higher in LV Dysfunction group than in Normal group (p=0.05). When only coordinates with RR-1 from 0.6 to 1 sec were included, Slope/Vpe-1 (p=0.001) was higher in LV Dysfunction group than in Normal group. Among the parameters between RR-2 and Vpe, Slope/Vpe-1, slope, and r2 were different between the two groups. In multivariate analysis, Slope/Vpe-1 between RR-2 and Vpe was only independent parameter. However, Slope/Vpe-1 between RR-1 and Vpe in the coordinates with RR-1 from 0.6 to 1 sec had the highest discriminating power. New parameters derived from the relations between RR intervals and LV performance might be useful to evaluate LV function quantitatively in AF.
Collapse
Affiliation(s)
- Hong Sook Ko
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Chung-Ang University, Seoul, Korea
| | - Chee Jeong Kim
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Chung-Ang University, Seoul, Korea
| | - Wang Seong Ryu
- Division of Cardiology, Department of Internal Medicine, College of Medicine, Chung-Ang University, Seoul, Korea
| |
Collapse
|
35
|
Wang CL, Lin KH, Luqman N, Chu PH, Hsu LA, Kuo CT. Simultaneous biplane single-beat assessment of left ventricular systolic function in patients with atrial fibrillation. Am J Cardiol 2004; 94:942-4. [PMID: 15464684 DOI: 10.1016/j.amjcard.2004.06.035] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2004] [Revised: 06/25/2004] [Accepted: 06/25/2004] [Indexed: 10/26/2022]
Abstract
Left ventricular systolic function was studied in 40 patients with atrial fibrillation using a matrix-array transducer, which enables 2 simultaneous orthogonal views to be obtained in a biplane mode. Bland-Altman analysis showed excellent correlation and agreement between the systolic parameters of a single beat with identical RR1 and RR2 intervals and the measured average value over all cardiac cycles.
Collapse
Affiliation(s)
- Chun-Li Wang
- Department of Cardiology, Chang Gung Memorial Hospital, Taipei, Taiwan
| | | | | | | | | | | |
Collapse
|
36
|
Lim HS, Hamaad A, Lip GYH. Clinical review: clinical management of atrial fibrillation - rate control versus rhythm control. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2004; 8:271-9. [PMID: 15312210 PMCID: PMC522829 DOI: 10.1186/cc2827] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia in the critically ill and is associated with adverse outcomes. Although there are plausible benefits from conversion and maintenance of sinus rhythm (the so-called 'rhythm-control' strategy), recent randomized trials have failed to demonstrate the superiority of this approach over the rate-control strategy. Regardless of approach, continuous therapeutic anticoagulation is crucial for stroke prevention. This review addresses the findings of these studies and their implications for clinical management of patients with atrial fibrillation.
Collapse
Affiliation(s)
- Hoong Sern Lim
- Research Fellow, University Department of Medicine, City Hospital, Birmingham, UK
| | - Ali Hamaad
- Research Fellow, University Department of Medicine, City Hospital, Birmingham, UK
| | - Gregory YH Lip
- Professor of Cardiovascular Medicine, University Department of Medicine, City Hospital, Birmingham, UK
| |
Collapse
|
37
|
Popović ZB, Mowrey KA, Zhang Y, Zhuang S, Tabata T, Wallick DW, Grimm RA, Thomas JD, Mazgalev TN. Slow rate during AF improves ventricular performance by reducing sensitivity to cycle length irregularity. Am J Physiol Heart Circ Physiol 2002; 283:H2706-13. [PMID: 12388219 DOI: 10.1152/ajpheart.00571.2002] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Atrial fibrillation (AF) is characterized by short and irregular ventricular cycle lengths (VCL). While the beneficial effects of heart rate slowing (i.e., the prolongation of VCL) in AF are well recognized, little is known about the impact of irregularity. In 10 anesthetized dogs, R-R intervals, left ventricular (LV) pressure, and aortic flow were collected for >500 beats during fast AF and when the average VCL was prolonged to 75%, 100%, and 125% of the intrinsic sinus cycle length by selective atrioventricular (AV) nodal vagal stimulation. We used the ratio of the preceding and prepreceding R-R intervals (RR(p)/RR(pp)) as an index of cycle length irregularity and assessed its effects on the maximum LV power, the minimum of the first derivative of LV pressure, and the time constant of relaxation by using nonlinear fitting with monoexponential functions. During prolongation of VCL, there was a pronounced decrease in curvature with the formation of a plateau, indicating a lesser dependence on RR(p)/RR(pp). We conclude that prolongation of the VCL during AF reduces the sensitivity of the LV performance parameters to irregularity.
Collapse
Affiliation(s)
- Zoran B Popović
- Department of Cardiovascular Medicine, The Cleveland Clinic Foundation, Ohio 44195, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Takagaki M, McCarthy PM, Chung M, Connor J, Dessoffy R, Ochiai Y, Howard M, Doi K, Kopcak M, Mazgalev TN, Fukamachi K. Preload-adjusted maximal power: a novel index of left ventricular contractility in atrial fibrillation. Heart 2002; 88:170-6. [PMID: 12117848 PMCID: PMC1767221 DOI: 10.1136/heart.88.2.170] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Left ventricular contractility in atrial fibrillation is known to change in a beat to beat fashion, but there is no gold standard for contractility indices in atrial fibrillation, especially those measured non-invasively. OBJECTIVE To determine whether the non-invasive index of contractility "preload-adjusted PWR(max)" (maximal ventricular power divided by the square of end diastolic volume) can accurately measure left ventricular contractility in a beat to beat fashion in atrial fibrillation. METHODS Atrial fibrillation was induced experimentally using 60 Hz stimulation of the atrium and maintained in 12 sheep; four received diltiazem, four digoxin, and four no drugs (control). Aortic flow, left ventricular volume, and left ventricular pressure were monitored simultaneously. Preload-adjusted PWR(max), the slope of the end systolic pressure-volume relation (E(max)), and the maximum rate of change of left ventricular pressure (dP/dt(max)) were calculated in a beat to beat fashion. RESULTS Preload-adjusted PWR(max) correlated linearly with load independent E(max) (p < 0.0001) and curvilinearly with load dependent dP/dt(max) (p < 0.0001), which suggested the load independence of preload-adjusted PWR(max). After five minutes of diltiazem administration, preload-adjusted PWR(max), dP/dt(max), and E(max) fell significantly (p < 0.0001) to 62%, 64%, and 61% of baseline, respectively. Changes were not significant after five minutes of digoxin (103%, 98%, and 102%) or in controls (97%, 96%, and 95%). CONCLUSIONS Preload-adjusted PWR(max) correlates linearly with E(max) and is a useful measure of contractility even in atrial fibrillation. Non-invasive application of this method, in combination with echocardiography and tonometry, may yield important information for optimising the treatment of patients with atrial fibrillation.
Collapse
Affiliation(s)
- M Takagaki
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Abstract
Atrial fibrillation occurs commonly in the setting of congestive heart failure and, in fact can cause left ventricular dysfunction due to a rapid ventricular response over time, termed tachycardia-mediated cardiomyopathy. The combination of atrial fibrillation and congestive heart failure leads to a high risk of stroke for the patient and appropriate antithrombotic therapy can minimize this incidence of stroke. Stroke risk can be markedly reduced by treatment with warfarin and complications of anticoagulation minimized by close attention to maintaining the INR between 2.0 and 3.0.
Collapse
|
40
|
Morita T, Araki J, Oshima Y, Mitani H, Iribe G, Mohri S, Shimizu J, Sano S, Kajiya F, Suga H. Frequency distribution, variance, and moving average of left ventricular rhythm and contractility during atrial fibrillation in dog. THE JAPANESE JOURNAL OF PHYSIOLOGY 2002; 52:41-9. [PMID: 12047801 DOI: 10.2170/jjphysiol.52.41] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Mean levels of left ventricular rhythm and contractility averaged over arrhythmic beats would characterize the average cardiac performance during atrial fibrillation (AF). However, no consensus exists on the minimal number of beats for their reliable mean values. We analyzed their basic statistics to find out such a minimal beat number in canine hearts. We produced AF by electrically stimulating the atrium and measured left ventricular arrhythmic beat interval (RR) and peak isovolumic pressure (LVP). From these, we calculated instantaneous heart rate (HR = 60,000/RR), contractility (E(max) = LVP/isovolumic volume above unstressed volume), and beat interval ratio (RR1/RR2). We found that all their frequency distributions during AF were variably nonnormal with skewness and kurtosis. Their means +/- standard deviations alone cannot represent their nonnormal distributions. A 90% reduction of variances of E(max) and RR1/RR2 required a moving average of 15 and 24, respectively, arrhythmic beats on the average, whereas that of RR and HR required 60 beats on the average. These results indicate that a statistical characterization of arrhythmic cardiodynamic variables facilitates better understanding of cardiac performance during AF.
Collapse
Affiliation(s)
- Terumasa Morita
- Department of Cardiovascular Physiology, Okayama University Graduate School of Medicine and Dentistry, Okayama, 700-8558 Japan
| | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Fuster V, Rydén LE, Asinger RW, Cannom DS, Crijns HJ, Frye RL, Halperin JL, Kay G, Klein WW, Lévy S, McNamara RL, Prystowsky EN, Wann L, Wyse D, Gibbons RJ, Antman EM, Alpert JS, Faxon DP, Fuster V, Gregoratos G, Hiratzka LF, Jacobs AK, Russell RO, Smith SC, Klein WW, Alonso-Garcia A, Blomström-Lundqvist C, De Backer G, Flather M, Hradec J, Oto A, Parkhomenko A, Silber S, Torbicki A. ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation31This document was approved by the American College of Cardiology Board of Trustees in August 2001, the American Heart Association Science Advisory and Coordinating Committee in August 2001, and the European Society of Cardiology Board and Committee for Practice Guidelines and Policy Conferences in August 2001.32When citing this document, the American College of Cardiology, the American Heart Association, and the European Society of Cardiology would appreciate the following citation format: Fuster V, Rydén LE, Asinger RW, Cannom DS, Crijns HJ, Frye RL, Halperin JL, Kay GN, Klein WW, Lévy S, McNamara RL, Prystowsky EN, Wann LS, Wyse DG. ACC/AHA/ESC guidelines for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for Practice Guidelines and Policy Conferences (Committee to Develop Guidelines for the Management of Patients With Atrial Fibrillation). J Am Coll Cardiol 2001;38:XX-XX.33This document is available on the World Wide Web sites of the American College of Cardiology (www.acc.org), the American Heart Association (www.americanheart.org), the European Society of Cardiology (www.escardio.org), and the North American Society of Pacing and Electrophysiology (www.naspe.org). Single reprints of this document (the complete Guidelines) to be published in the mid-October issue of the European Heart Journal are available by calling +44.207.424.4200 or +44.207.424.4389, faxing +44.207.424.4433, or writing Harcourt Publishers Ltd, European Heart Journal, ESC Guidelines – Reprints, 32 Jamestown Road, London, NW1 7BY, United Kingdom. Single reprints of the shorter version (Executive Summary and Summary of Recommendations) published in the October issue of the Journal of the American College of Cardiology and the October issue of Circulation, are available for $5.00 each by calling 800-253-4636 (US only) or by writing the Resource Center, American College of Cardiology, 9111 Old Georgetown Road, Bethesda, Maryland 20814. To purchase bulk reprints specify version and reprint number (Executive Summary 71-0208; full text 71-0209) up to 999 copies, call 800-611-6083 (US only) or fax 413-665-2671; 1000 or more copies, call 214-706-1466, fax 214-691-6342; or E-mail: pubauth@heart.org. J Am Coll Cardiol 2001. [DOI: 10.1016/s0735-1097(01)01586-8] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
42
|
Harada K, Sugishita Y, Shimizu T, Yao A, Matsui H, Kohmoto O, Serizawa T, Nagai R, Takahashi T. Left ventricular relaxation abnormality is detectable by analysis of the relaxation time constant in patients with atrial fibrillation. JAPANESE CIRCULATION JOURNAL 2001; 65:610-6. [PMID: 11450688 DOI: 10.1253/jcj.65.610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Left ventricular (LV) contractility is constantly changing during atrial fibrillation (AF), which is dependent on the force-interval relationships. However, no information has been available on LV relaxation in patients with both AF and impaired LV systolic function. LV pressure was measured with a catheter-tipped micromanometer and the time constant of isovolumic LV pressure decline (tau(bf)) was calculated with best exponential fitting from more than 10 consecutive beats. Patients with AF (5 with mitral valvular disease, 6 with idiopathic dilated cardiomyopathy, and 1 with no underlying disease) were subdivided into 2 groups: group A, with ejection fraction (EF) <0.5 (n=7); and group B, with EF > or =0.5 (n=5). Linear correlation coefficients (r) between tau and RR2, RR2/RR1, LV peak systolic pressure (peak LVP) were calculated. Although tau did not show a discrepancy between the 2 groups, tau(bf) correlated better with RR2/RR1 only in the group A patients. The relation between tau and peak LVP showed a good correlation with a steep slope (R, Deltatau/Deltapeak LVP) only in the group A patients (accentuated afterload-dependence). R was significantly different between the 2 groups. Thus, a beat-to-beat analysis of tau may be a practical and feasible way for detecting LV relaxation abnormality in patients with AF.
Collapse
Affiliation(s)
- K Harada
- Department of Cardiovascular Medicine, University of Tokyo, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Nagahama Y, Schick EC, Gaasch WH. Interval-dependent potentiation of left ventricular contractility is preserved in patients with atrial fibrillation and depressed ejection fraction. Am J Cardiol 2001; 87:342-6, A9. [PMID: 11165975 DOI: 10.1016/s0002-9149(00)01373-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Echocardiographic techniques were used to measure left ventricular isovolumic and ejection phase indexes of contractility in 54 patients with atrial fibrillation, and the relations between cycle lengths and contractility were compared in patients with normal and depressed ejection fractions. Data indicate that variations in contractility occur in a pattern that is consistent with postextrasystolic potentiation and that such interval-dependent potentiation is preserved in patients with atrial fibrillation and depressed ejection fraction.
Collapse
Affiliation(s)
- Y Nagahama
- Department of Cardiovascular Medicine, Lahey Clinic, Burlington, Massachusetts, USA
| | | | | |
Collapse
|
44
|
Effat M, Schick EC, Martin DT, Gaasch WH. Effect of rhythm regularization on left ventricular contractility in patients with atrial fibrillation. Am J Cardiol 2000; 85:114-6, A9. [PMID: 11078251 DOI: 10.1016/s0002-9149(99)00620-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
In 10 patients with atrial fibrillation, echocardiographic measures of left ventricular function-interval relations were used to assess contractility and to test the hypothesis that rhythm regularization produces a higher contractile state than is seen when the rhythm is irregular. Regularization, following direct-current cardioversion, did not augment ventricular contractility above that seen during atrial fibrillation.
Collapse
Affiliation(s)
- M Effat
- Department of Medicine, Lahey Clinic, Burlington, Massachusetts, USA
| | | | | | | |
Collapse
|
45
|
Silverman DI, Walsh S, Golden S, Raymond RJ, Lee AJ, Katz AM. Interval-force relation is unaffected by the presence of cardiomyopathy or coronary artery disease in patients with atrial fibrillation. J Card Fail 1999; 5:100-8. [PMID: 10404349 DOI: 10.1016/s1071-9164(99)90032-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND We tested the hypothesis that cycle length-dependent cardiac contractility in atrial fibrillation is primarily governed by the negative interval-force relation in patients with normal and depressed systolic function. METHODS AND RESULTS We performed two-dimensional guided M-mode echocardiography in 41 patients (mean age, 69 +/- 4 years; range, 48 to 92 years; 19 men, 11 women). Twelve patients had objective evidence of left ventricular systolic dysfunction (CMP; mean ejection fraction, 37% +/- 7%) in the absence of coronary artery disease (CAD), 13 patients had documented CAD (mean ejection fraction, 43% +/- 6%), and 16 patients had normal resting left ventricular systolic function (mean ejection fraction, 58% +/- 7%). Simultaneous beat-to-beat blood pressure, end-systolic and end-diastolic dimension, circumferential velocity of fiber shortening (Vcf), and end-systolic wall stress (ESWS) were calculated for all patients. All three groups showed a significant linear relation between beat-to-beat Vcf and Vcf corrected for afterload (represented as the Vcf/ESWS ratio) and preceding cycle length. There was, however, no significant difference in the relation between either of these variables and cycle length among the three groups. There was also no difference in the rate of change in either Vcf or Vcf corrected for afterload (Vcf/ESWS ratio) from beat-to-beat among the three groups. Control patients with normal systolic function showed greater Vcf at any given cycle length compared with patients with CMP or CAD. CONCLUSION Our data show that, for each beat in atrial fibrillation, Vcf and Vcf/ESWS ratio are decreased after shorter cycle lengths and increased after long cycles, but there is no significant attenuation of this effect in patients with systolic dysfunction with or without coronary disease compared with controls. Thus, the negative interval-force relation, the predominant determinant of beat-to-beat variation in contractility in atrial fibrillation, is preserved in patients with CAD or reduced left ventricular systolic function.
Collapse
Affiliation(s)
- D I Silverman
- Department of Medicine, University of Connecticut School of Medicine, Farmington, USA
| | | | | | | | | | | |
Collapse
|