1
|
Rodina ES, Fettser EI, Novikov IA. [Methods for assessing the microbiological diversity of the ocular surface]. Vestn Oftalmol 2024; 140:96-108. [PMID: 38962985 DOI: 10.17116/oftalma202414003196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/05/2024]
Abstract
This review compares data from scientific studies on the microbial community of the ocular surface (OS) in conditionally healthy individuals using cultural methods (including culture-dependent diagnostic tests), microscopic and molecular genetic methods, and assesses the influence of research methods and sample preparation on the results. Concordance and discordance of the sets of identified microorganisms were analyzed using overlapping and non-overlapping methods of studying the microbial community of a healthy OS. The article presents tables showing the names of microorganisms that were identified in different sources. Cross-verification in taxa of different ranks helped confirm the following most frequently found microorganisms on healthy OS: coccomorphic microorganisms of the genera Staphylococcus, Micrococcus, Kocuria, Streptococcus, Enterococcus; gram-positive spore-forming bacilli of the genera Bacillus and Paenibacillus; gram-positive non-spore-forming rod-shaped bacteria, including Corynebacterium, but excluding Propionibacterium and Microbacterium; gram-negative non-spore-forming rod-shaped microorganisms of the genera Moraxella and Serratia. The study also assessed the effect of wearing soft contact lenses on the composition of the microbial community of the OS.
Collapse
Affiliation(s)
- E S Rodina
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
| | - E I Fettser
- I.M. Sechenov First Moscow State Medical University (Sechenov University), Moscow, Russia
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
| | - I A Novikov
- Krasnov Research Institute of Eye Diseases, Moscow, Russia
| |
Collapse
|
2
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
3
|
Harris V, Pifer R, Shannon P, Crary M. Comparative Evaluation of Pseudomonas aeruginosa Adhesion to a Poly-(2-Methacryloyloxyethyl Phosphorylcholine)-Modified Silicone Hydrogel Contact Lens. Vision (Basel) 2023; 7:vision7010027. [PMID: 36977307 PMCID: PMC10056565 DOI: 10.3390/vision7010027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 03/17/2023] [Accepted: 03/19/2023] [Indexed: 03/30/2023] Open
Abstract
Pseudomonas aeruginosa is the most common causative agent associated with microbial keratitis. During contact lens wear, pathogens may be introduced into the ocular environment, which might cause adverse events. Lehfilcon A is a recently developed contact lens with a water gradient surface composed of polymeric 2-methacryloyloxyethyl phosphorylcholine (MPC). MPC is re-ported to impart anti-biofouling properties onto modified substrates. Therefore, in this in vitro experimental study, we tested the capability of lehfilcon A to resist adhesion by P. aeruginosa. Quantitative bacterial adhesion assays using five strains of P. aeruginosa were conducted to compare the adherence properties of lehfilcon A to five currently marketed silicone hydrogel (SiHy) contact lenses (comfilcon A, fanfilcon A, senofilcon A, senofilcon C, and samfilcon A). Compared to lehfilcon A, we observed 26.7 ± 8.8 times (p = 0.0028) more P. aeruginosa binding to comfilcon A, 30.0 ± 10.8 times (p = 0.0038) more binding to fanfilcon A, 18.2 ± 6.2 times (p = 0.0034) more binding to senofilcon A, 13.6 ± 3.9 times (p = 0.0019) more binding to senofilcon C, and 29.5 ± 11.8 times (p = 0.0057) more binding to samfilcon A. These results demonstrate that, for various strains of P. aeruginosa, lehfilcon A reduces bacterial adhesion compared to other contact lens materials.
Collapse
Affiliation(s)
| | - Reed Pifer
- Alcon Research, LLC, Fort Worth, TX 76134, USA
| | | | | |
Collapse
|
4
|
Ţălu Ş. Advanced morphological analysis of siloxane-hydrogel contact lenses. Microsc Res Tech 2021; 84:2702-2715. [PMID: 34036670 DOI: 10.1002/jemt.23833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Revised: 04/29/2021] [Accepted: 05/06/2021] [Indexed: 02/05/2023]
Abstract
The purpose of this work is to provide a better understanding of three-dimensional (3-D) surface texture of siloxane-hydrogel contact lenses (CLs) using atomic force microscopy (AFM) and stereometric analysis. The 3-D surface texture characterization of unworn/worn siloxane-hydrogel CLs made of Filcon V (I FDA group) was performed with stereometric analysis. The atomic force microscopy (AFM) measurements of surface roughness and micromorphology of CLs were made using a Nanoscope V MultiMode (Bruker) in intermittent-contact mode, in air, on square areas of 5 × 5 μm. Stereometric study of 3-D surface texture was made according with ISO 25178-2:2012 for CLrins (taken from the blister and rinsed with deionized water); CLss (preserved for 12 hr in saline solution and rinsed with deionized water); CLworn-smooth (worn for 8 hr and presenting the smooth type morphology), and CLworn-sharp (worn for 8 hr and presenting the sharp-type morphology). The 3-D surface texture of siloxane-hydrogel CLs was found to have specific morphological characteristics. Statistical parameters revealed local geometrical and morphological spatial structures at nanometer scale attributed to the specific interactions at the CLs surface. Before wear, the surface micromorphology of Filcon V CLs is regular with uniformly distributed microasperities and relatively small heights (Sq = 0.6 nm). After 12 hr in saline, it is found that the micromorphology changes relatively easily, but retaining the main morphological characteristics (Sq = 1.2 nm). After 8 hr of wear, there are two typical micromorphologies: smooth type, characterized by gutter structures and isolated microasperities (Sq = 2.5 nm), while the sharp type has an appearance with compactly arranged microasperities of hill type flanked by compactly arranged microregions of valley type (Sq = 2.2 nm). Surface statistical parameters allow manufacturers in developing the next generation of CLs with improved surface texture while improving biocompatibility and minimizing the impact of the material on corneal physiology. Furthermore, the micro-elastohydrodynamic lubrication due to surface texture at a nanometer scale between the back surface of the CL with the corneal surface and the front surface of the CL with the under-surface of the eyelid can be deeper and more nuanced to understand in light of modern tribological theories.
Collapse
Affiliation(s)
- Ştefan Ţălu
- The Directorate of Research, Development and Innovation Management (DMCDI), Technical University of Cluj-Napoca, Cluj-Napoca, Romania
| |
Collapse
|
5
|
Miglio F, Ponzini E, Zeri F, Borghesi A, Tavazzi S. In vitro affinity for nicotine of soft contact lenses of different materials. Cont Lens Anterior Eye 2021; 45:101490. [PMID: 34294534 DOI: 10.1016/j.clae.2021.101490] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 07/02/2021] [Accepted: 07/07/2021] [Indexed: 02/06/2023]
Abstract
Smoking is a risk factor for the development of microbial keratitis and corneal infiltrates in contact lens (CL) wearers. It is still unknown if this risk is directly associated with the presence of nicotine in the eye and if adherence of nicotine on the CL can enhance these effects. A better understanding of the interaction between nicotine and CL materials could offer insights to explain this risk associated with smoking. The aim of this work was to compare the affinity of nicotine to different soft CL materials. CLs from FDA groups I, II, IV, and V were incubated in a 2-mM nicotine solution for 24 h and then in a 0.9% saline solution for the next 24 h. The amount of absorbed and released nicotine per CL was deduced as a function of time (t) by ultraviolet (UV) spectrophotometry and normalised to the mass of the hydrated CL. The data were described by the equation y = b -a t-1, where a and b are constants, and b represents the mass reached at the plateau after ~ 10 min of exposure. Groups IV and V displayed the highest (0.80 ± 0.09 µg) and lowest (0.27 ± 0.08 µg) nicotine absorption per mg of hydrated CL, respectively. The CL affinity for nicotine could be ascribed to the interaction between the positive charge of nicotine pyrrolidine nitrogen and the negative charges of the CLs, especially for the ionic IV group.
Collapse
Affiliation(s)
- Federica Miglio
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy
| | - Erika Ponzini
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy.
| | - Fabrizio Zeri
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy; School of Life & Health Sciences, Aston University, Aston Triangle, Birmingham B4 7ET, UK
| | - Alessandro Borghesi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy
| | - Silvia Tavazzi
- University of Milano Bicocca, Materials Science Department, via R. Cozzi 55, I-20125 Milan, Italy; University of Milano Bicocca, COMiB Research Center, via R. Cozzi 55, I-20125 Milan, Italy
| |
Collapse
|
6
|
Kalaiselvan P, Konda N, Pampi N, Vaddavalli PK, Sharma S, Stapleton F, Kumar N, Willcox MDP, Dutta D. Effect of Antimicrobial Contact Lenses on Corneal Infiltrative Events: A Randomized Clinical Trial. Transl Vis Sci Technol 2021; 10:32. [PMID: 34191016 PMCID: PMC8254012 DOI: 10.1167/tvst.10.7.32] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To determine whether Mel4-coated antimicrobial contact lenses (MACLs) can reduce the incidence of corneal infiltrative events (CIEs) during extended wear. Methods A prospective, randomized, double-masked, single-center, contralateral, extended contact lens wear clinical trial was conducted with 176 subjects. Each participant was randomly assigned to wear a MACL in one eye and an uncoated control contact lens in the contralateral eye or an extended-wear biweekly disposable modality for 3 months. The main outcome measures were the incidence of CIEs per 100 eye-months, identification of the microbial types colonizing the contact lenses or eyes at the time of the CIEs, and their susceptibility to Mel4. Results Nine participants (5.1%) experienced unilateral CIEs; six participants had contact lens acute red eye, and three participants had infiltrative keratitis. The incidence rate for CIEs (0.4 events per 100 participant months; 1.7%) in the Mel4-coated lenses (test) was 69% less than that of the control lenses (1.3 events per 100 participant months; 3.4%; P = 0.29). All Gram-negative bacteria isolated from lenses and lids of participants with CIEs (Citrobacter diversus, Acinetobacter haemolyticus, and Acinetobacter lwoffii) were susceptible to Mel4 peptide; minimum inhibitory concentrations ranged from 15.6 to 62.5 µg/mL. Reduction of adhesion of these bacteria by Mel4-coated lenses ranged from 2.1 to 2.2 log10 colony-forming units/lens. Conclusions MACLs had the capacity to reduce CIEs by at least 50% compared with uncoated control lenses during extended wear over 3 months; however, due to the relatively low rates of CIEs, the reduction was not statistically different compared with control lenses. Translational Relevance This study provides evidence that antimicrobial contact lenses have the potential to reduce the incidence of corneal infiltrative events during extended wear.
Collapse
Affiliation(s)
| | - Nagaraju Konda
- School of Medical Sciences, University of Hyderabad, Hyderabad, India
| | - Nending Pampi
- Bausch & Lomb Contact Lens Centre, L V Prasad Eye Institute, Hyderabad, India
| | - Pravin Krishna Vaddavalli
- Bausch & Lomb Contact Lens Centre, L V Prasad Eye Institute, Hyderabad, India.,The Cornea Institute, L V Prasad Eye Institute, Hyderabad, India
| | - Savitri Sharma
- Jhaveri Microbiology Centre, L V Prasad Eye Institute, Hyderabad, India
| | - Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Naresh Kumar
- School of Chemistry, University of New South Wales, Sydney, Australia
| | - Mark D P Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Debarun Dutta
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.,School of Optometry, Aston University, Birmingham, UK
| |
Collapse
|
7
|
The State of the Art about Etiopathogenetic Models on Breast Implant Associated-Anaplastic Large Cell Lymphoma (BIA-ALCL): A Narrative Review. J Clin Med 2021; 10:jcm10102082. [PMID: 34066230 PMCID: PMC8151182 DOI: 10.3390/jcm10102082] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 05/10/2021] [Accepted: 05/11/2021] [Indexed: 12/22/2022] Open
Abstract
Background: Breast-implant-associated anaplastic large cell lymphoma is a rare malignancy linked to texturized breast implants. Although many researchers focus on its etiopathogenesis, this topic is affected by a lack of evidence. Materials and Methods: A literature review about BIA-ALCL was made. Results and conclusions: Although the incidence is reported between 1:355–1:30,000, there is great attention to BIA-ALCL. The incidence is uncertain due to many reasons. It may well be lower, due to inclusion in multiple databases as pointed out by the FDA and undiagnosed cases. The role of chronic inflammation, bacterial contamination, and mechanical forces was discussed. Clarification is needed to understand the mechanisms underlying the progression of alterations and mutations for BIA-ALCL; new molecular analysis and pathogenetic models should be investigated.
Collapse
|
8
|
Tan J, Siddireddy JS, Wong K, Shen Q, Vijay AK, Stapleton F. Factors Affecting Microbial Contamination on the Back Surface of Worn Soft Contact Lenses. Optom Vis Sci 2021; 98:512-517. [PMID: 33973914 PMCID: PMC8132605 DOI: 10.1097/opx.0000000000001693] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 01/10/2021] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE The results of this study demonstrate that Smart Touch Technology packaging, which is designed to reduce and simplify contact lens handling before insertion, is effective in reducing the frequency of bacterial contamination of the back surface of contact lenses after short-term wear. PURPOSE The purpose of this study was to investigate the effect of lens packaging type, chelating agent, and finger contamination on microbial contamination on the back surface of worn soft contact lenses. METHODS Twenty-five subjects completed each contralateral lens wear comparison in this randomized study: Smart Touch Technology versus conventional blister packaging for (1) silicone hydrogel lenses with ethylenediaminetetraacetic acid (EDTA) and (2) hydrogel lenses without EDTA in the packaging, and (3) silicone hydrogel lenses without EDTA versus hydrogel lenses with EDTA both in Smart Touch Technology packaging. Participants washed hands, underwent finger swabs, and inserted the lenses. After 45 minutes, lenses were removed aseptically and the posterior lens surfaces cultured. RESULTS Thirty-eight subjects (average age, 30.9 ± 12.5 years) participated in this study. Overall, the level of back surface contamination was low for both lens materials, ranging from 0 to 43 colony-forming unit (CFU)/lens for the silicone hydrogel and 0 to 17 CFU/lens for the hydrogel lenses. The proportion of lenses with zero back surface contamination ranged from 16 to 64% for silicone hydrogel lenses and 28 to 64% for hydrogel lenses. Contact lenses from conventional packaging containing EDTA had 3.38 times increased risk (95% confidence interval [CI], 1.02 to 11.11; P = .05) of contamination being present compared with lenses from Smart Touch packaging with EDTA. Contact lenses from conventional packaging without EDTA had 3.4 times increased risk (95% CI, 1.02 to 11.36; P = .05) of contamination being present compared with Smart Touch packaging without EDTA, and silicone hydrogel lenses had a 6.28 times increased risk (95% CI, 1.65 to 23.81; P = .007) of contamination being present compared with hydrogels. The median (interquartile range) number of bacteria isolated from fingers used to perform lens insertion after handwashing but before lens insertion was not significantly different between the silicone hydrogel and hydrogel lenses (63.7 [204.2] vs. 59 [84.5], P = .09). Finger contamination was not significantly associated with lens contamination in the presence or absence of EDTA. CONCLUSIONS Smart Touch Technology packaging was effective in reducing the proportion of contaminated lenses. Although silicone hydrogel lenses were more likely to be contaminated, the presence of EDTA ameliorated this effect. Finger contamination was not associated with lens contamination.
Collapse
Affiliation(s)
| | - Jaya Sowjanya Siddireddy
- Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Katherine Wong
- Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Qing Shen
- Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Ajay Kumar Vijay
- Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Fiona Stapleton
- Faculty of Medicine and Health, School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
9
|
Efron N. Putting vital stains in context. Clin Exp Optom 2021; 96:400-21. [DOI: 10.1111/j.1444-0938.2012.00802.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2011] [Revised: 06/17/2012] [Accepted: 06/19/2012] [Indexed: 11/30/2022] Open
Affiliation(s)
- Nathan Efron
- Institute of Health and Biomedical Innovation, and School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia,
| |
Collapse
|
10
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
11
|
CLEAR - Contact lens complications. Cont Lens Anterior Eye 2021; 44:330-367. [DOI: 10.1016/j.clae.2021.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
|
12
|
Wolffsohn JS, Dumbleton K, Huntjens B, Kandel H, Koh S, Kunnen CME, Nagra M, Pult H, Sulley AL, Vianya-Estopa M, Walsh K, Wong S, Stapleton F. CLEAR - Evidence-based contact lens practice. Cont Lens Anterior Eye 2021; 44:368-397. [PMID: 33775383 DOI: 10.1016/j.clae.2021.02.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Evidence-based contact lens -->practice involves finding, appraising and applying research findings as the basis for patient management decisions. These decisions should be informed by the strength of the research study designs that address the question, as well as by the experience of the practitioner and the preferences and environment of the patient. This reports reviews and summarises the published research evidence that is available to inform soft and rigid contact lens history and symptoms taking, anterior eye health examination (including the optimised use of ophthalmic dyes, grading scales, imaging techniques and lid eversion), considerations for contact lens selection (including the ocular surface measurements required to select the most appropriate lens parameter, lens modality and material selection), evaluation of lens fit, prescribing (teaching self-application and removal, adaptation, care regimen and cleaning instructions, as well as -->minimising risks of lens wear through encouraging compliance) and an aftercare routine.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- School of Optometry, University of California, Berkeley, CA, USA
| | - Byki Huntjens
- Division of Optometry and Visual Sciences at City, University of London, London, UK
| | - Himal Kandel
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Japan
| | | | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Cambridge, UK
| | - Heiko Pult
- Optometry and Vision Research, Weinheim, Germany
| | | | - Marta Vianya-Estopa
- Department of Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Karen Walsh
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Stephanie Wong
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
13
|
The Relationship between Corneal Nerve Morphology and Inflammatory Mediators and Neuropeptides in Healthy Individuals. Optom Vis Sci 2021; 97:145-153. [PMID: 32168236 DOI: 10.1097/opx.0000000000001484] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
SIGNIFICANCE This study set out to explore the relationship between the ocular surface immune and nervous systems by exploring corneal nerve structure and the presence of inflammatory mediators and neuropeptides in the tear film. PURPOSE The purpose of this study was to determine the association between corneal nerve morphology and tear film inflammatory mediators and a neuropeptide in healthy individuals. METHODS Flush tears were collected from both eyes of 21 healthy participants aged 39.7 ± 9.9 years (10 females, 11 males) and analyzed for substance P, matrix metalloproteinase-9, tissue inhibitor of matrix metalloproteinase-1 (TIMP-1), tumor necrosis factor α, and interleukin 6. In vivo central corneal confocal microscopy was performed on the right eye, and eight images were captured. Variables measured were corneal nerve fiber length (CNFL), corneal nerve density (CNFD), corneal nerve branch density, fiber total branch density, corneal nerve fiber area, corneal nerve fiber width (CNFW), and corneal nerve fractal dimension (CNFrac). For each eye, the average across the images and the maximum and minimum values were determined for each variable. Pearson correlation analysis was performed to test for associations. RESULTS Substance P correlated with CNFrac (max) (r = -0.48, P = .03) and CNFW (min) (r = -0.52, P = .02). TIMP-1 correlated with CNFD (average) (r = -0.53, P = .03), CNFL (average) (r = -0.49, P = .05), CNFrac (max) (r = -0.49, P = .05), and CNFD (min) (r = -0.55, P = .02). Interleukin 6 correlated with CNFW (average) (r = -0.49, P = .05), the standard deviation of CNFL (r = -0.51, P = .04), CNFL (max) (r = -0.50, P = .04), CNFrac (max) (r = -0.50, P = .04), and CNFW (min) (r = -0.55, P = .02). Tumor necrosis factor α, matrix metalloproteinase-9, and its ratio with TIMP-1 did not correlate with any corneal nerve parameters. CONCLUSIONS Both inflammatory mediators and neuropeptides correlated with measures of corneal nerve morphology, supporting the link between the inflammatory and nervous systems.
Collapse
|
14
|
Ocular microbiota and lens contamination following Mel4 peptide-coated antimicrobial contact lens (MACL) extended wear. Cont Lens Anterior Eye 2021; 45:101431. [PMID: 33676840 DOI: 10.1016/j.clae.2021.02.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 01/31/2021] [Accepted: 02/20/2021] [Indexed: 12/28/2022]
Abstract
PURPOSE The purpose of this study was to investigate the effect of Mel4 antimicrobial peptide-coated contact lenses (MACL) on the microbiota of the conjunctiva and lenses during three months of extended wear. METHODS One hundred and seventy-six participants were recruited into a randomised, contralateral, double masked, biweekly extended wear MACL and uncoated control lens trial. At the one month and 3-month visit, the conjunctival microbiota was sampled using sterile cotton swabs and contact lenses were collected aseptically. Standard microbiological procedures were employed for culture of the swabs and contact lenses and identification of the isolated microorganisms. RESULTS Gram-positive bacteria (predominantly coagulase-negative staphylococci) were the most frequently isolated microbes from both contact lenses and conjunctiva. There was no difference in the frequency of isolation of most bacteria or fungi from the conjunctival swabs of eyes wearing either MACL or control lenses. The only exception was a higher frequency of eyes harbouring Staphylococcus arlettae when wearing control lenses (5%) versus MACL (<1%) (p = 0.002). There was no significant difference in the frequency of microbes isolated from MACL or control contact lenses. There were also no differences between lens types in the frequency of isolation of >1 microbial type per sampling occasion for either conjunctiva swabs or contact lenses. CONCLUSION MACL wear did not change the conjunctival microbiota during extended wear, and the types of microbes isolated from MACL were similar to those isolated from control lenses.
Collapse
|
15
|
Mitchell GL, Richdale K, Lam D, Wagner H, Kinoshita BT, Zimmerman AB, Sorbara L, Rosner B. Development of a contact Lens risk survey. Cont Lens Anterior Eye 2020; 44:101383. [PMID: 33281075 DOI: 10.1016/j.clae.2020.11.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 10/29/2020] [Accepted: 11/09/2020] [Indexed: 11/18/2022]
Abstract
PURPOSE To describe the development and report psychometric properties of the Contact Lens Risk Survey (CLRS) to identify patients at risk for soft contact lens-related complications. METHODS Psychometric properties of the CLRS, a web-based survey with branching logic, were determined using data from 5 multi-site fieldings (n = 1059), including re-fielding to sub groups. Responses from participants with and without an active red eye were used to identify risk factors of a red eye event and calculate an overall risk score. A 6th fielding of the CLRS (n = 171) was used to assess discriminate validity. RESULTS Participants needed 11-12 min to complete the survey with a negligible difference by age. Internal consistency was excellent (Cronbach's α ≥ 0.70) for 3 of the 5 constructs identified by factor analysis. Twelve of the 17 survey items exhibited excellent within-subject repeatability (Kappa ≥ 0.61). Between-subject agreement, assessed in 18-25 year olds, was high for the majority of items, suggesting good generalizability across different populations of SCL wearers. The ability of the model using individual items of the CLRS to discriminate Controls and participants with a red eye was good with an area under the curve of 0.779. CONCLUSION The CLRS tool is a repeatable and valid instrument to standardize documentation of demographic, behavior, and exposure factors which appear to drive the greatest risk of a contact lens related red eye event.
Collapse
Affiliation(s)
- G Lynn Mitchell
- Ohio State University, College of Optometry, Columbus, OH, United States.
| | - Kathryn Richdale
- University of Houston, College of Optometry, Houston, TX, United States
| | - Dawn Lam
- Marshall B. Ketchum University, College of Optometry, Fullerton, CA, United States
| | - Heidi Wagner
- Ohio State University, College of Optometry, Columbus, OH, United States
| | - Beth T Kinoshita
- Pacific University, College of Optometry, Forest Grove, OR, United States
| | - Aaron B Zimmerman
- Ohio State University, College of Optometry, Columbus, OH, United States
| | - Luigina Sorbara
- University of Waterloo, School of Optometry, Waterloo, ON, Canada
| | - Bernard Rosner
- Harvard University, T. H Chan School of Public Health, Boston, MA, United States
| |
Collapse
|
16
|
Makrynioti D, Zagoriti Z, Koutsojannis C, Morgan PB, Lagoumintzis G. Ocular conditions and dry eye due to traditional and new forms of smoking: A review. Cont Lens Anterior Eye 2020; 43:277-284. [PMID: 32111452 DOI: 10.1016/j.clae.2020.02.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 01/24/2020] [Accepted: 02/16/2020] [Indexed: 12/26/2022]
Abstract
Addiction to cigarette smoking has high prevalence rates recorded worldwide. Smoking has been linked to several life-threatening systemic conditions such as cancer, heart attack and stroke, in addition to a range of ocular pathologies. In recent years, electronic cigarettes (EC) have emerged as alternatives to smoking. ECs are nicotine delivery devices which produce an aerosol by heating, rather than combusting, a liquid which contains nicotine, flavours and preservatives. This review focuses on the association of traditional and new forms of smoking with dry eye disease, contact lens wear and four other common ocular diseases: cataract, age-related macular degeneration, glaucoma and Graves' ophthalmopathy. It is concluded that smoking and vaping appear as a risk factor for the aforementioned ocular conditions. An evidence-based, clear link between cigarette smoking, or EC vaping and ocular problems is yet to be discovered.
Collapse
Affiliation(s)
- Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras, Psaron 6, GR 25100, Aιgio, Greece.
| | - Zoi Zagoriti
- Department of Pharmacy, Laboratory of Molecular Biology and Immunology, University of Patras, University Campus, GR26504, Patras, Greece.
| | - Constantinos Koutsojannis
- Department of Physiotherapy, Laboratory of Health Physics and Computational Intelligence, School of Health Rehabilitation Sciences, University of Patras, Psaron 6, GR 25100, Aιgio, Greece.
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Carys Bannister Building, Dover Street, Manchester, M13 9PL, United Kingdom.
| | - George Lagoumintzis
- School of Health Rehabilitation Sciences, University of Patras, Psaron 6, GR 25100, Aιgio, Greece; Department of Pharmacy, Laboratory of Molecular Biology and Immunology, University of Patras, University Campus, GR26504, Patras, Greece.
| |
Collapse
|
17
|
Dantam J, Subbaraman LN, Jones L. Adhesion of Pseudomonas aeruginosa, Achromobacter xylosoxidans, Delftia acidovorans, Stenotrophomonas maltophilia to contact lenses under the influence of an artificial tear solution. BIOFOULING 2020; 36:32-43. [PMID: 31973583 DOI: 10.1080/08927014.2019.1710832] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2019] [Revised: 12/25/2019] [Accepted: 12/27/2019] [Indexed: 06/10/2023]
Abstract
Corneal infection is a devastating sight-threatening complication that is associated with contact lens (CL) wear, commonly caused by Pseudomonas aeruginosa. Lately, Achromobacter xylosoxidans, Delftia acidovorans, and Stenotrophomonas maltophilia have been associated with corneal infection. This study investigated the adhesion of these emerging pathogens to CLs, under the influence of an artificial tear solution (ATS) containing a variety of components commonly found in human tears. Two different CL materials, etafilcon A and senofilcon A, either soaked in an ATS or phosphate buffered saline, were exposed to the bacteria. Bacterial adhesion was investigated using a radio-labeling technique (total counts) and plate count method (viable counts). The findings from this study revealed that in addition to P. aeruginosa, among the emerging pathogens evaluated, A. xylosoxidans showed an increased propensity for adherence to both CL materials and S. maltophilia showed lower viability. ATS influenced the viable counts more than the total counts on CLs.
Collapse
Affiliation(s)
- Jaya Dantam
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Lakshman N Subbaraman
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| |
Collapse
|
18
|
Fleiszig SMJ, Kroken AR, Nieto V, Grosser MR, Wan SJ, Metruccio MME, Evans DJ. Contact lens-related corneal infection: Intrinsic resistance and its compromise. Prog Retin Eye Res 2019; 76:100804. [PMID: 31756497 DOI: 10.1016/j.preteyeres.2019.100804] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2019] [Revised: 11/05/2019] [Accepted: 11/12/2019] [Indexed: 12/20/2022]
Abstract
Contact lenses represent a widely utilized form of vision correction with more than 140 million wearers worldwide. Although generally well-tolerated, contact lenses can cause corneal infection (microbial keratitis), with an approximate annualized incidence ranging from ~2 to ~20 cases per 10,000 wearers, and sometimes resulting in permanent vision loss. Research suggests that the pathogenesis of contact lens-associated microbial keratitis is complex and multifactorial, likely requiring multiple conspiring factors that compromise the intrinsic resistance of a healthy cornea to infection. Here, we outline our perspective of the mechanisms by which contact lens wear sometimes renders the cornea susceptible to infection, focusing primarily on our own research efforts during the past three decades. This has included studies of host factors underlying the constitutive barrier function of the healthy cornea, its response to bacterial challenge when intrinsic resistance is not compromised, pathogen virulence mechanisms, and the effects of contact lens wear that alter the outcome of host-microbe interactions. For almost all of this work, we have utilized the bacterium Pseudomonas aeruginosa because it is the leading cause of lens-related microbial keratitis. While not yet common among corneal isolates, clinical isolates of P. aeruginosa have emerged that are resistant to virtually all currently available antibiotics, leading the United States CDC (Centers for Disease Control) to add P. aeruginosa to its list of most serious threats. Compounding this concern, the development of advanced contact lenses for biosensing and augmented reality, together with the escalating incidence of myopia, could portent an epidemic of vision-threatening corneal infections in the future. Thankfully, technological advances in genomics, proteomics, metabolomics and imaging combined with emerging models of contact lens-associated P. aeruginosa infection hold promise for solving the problem - and possibly life-threatening infections impacting other tissues.
Collapse
Affiliation(s)
- Suzanne M J Fleiszig
- School of Optometry, University of California, Berkeley, CA, USA; Graduate Group in Vision Science, University of California, Berkeley, CA, USA; Graduate Groups in Microbiology and Infectious Diseases & Immunity, University of California, Berkeley, CA, USA.
| | - Abby R Kroken
- School of Optometry, University of California, Berkeley, CA, USA
| | - Vincent Nieto
- School of Optometry, University of California, Berkeley, CA, USA
| | | | - Stephanie J Wan
- Graduate Group in Vision Science, University of California, Berkeley, CA, USA
| | | | - David J Evans
- School of Optometry, University of California, Berkeley, CA, USA; College of Pharmacy, Touro University California, Vallejo, CA, USA
| |
Collapse
|
19
|
Diversity of Ocular Surface Bacterial Microbiome Adherent to Worn Contact Lenses and Bacterial Communities Associated With Care Solution Use. Eye Contact Lens 2019; 45:331-339. [DOI: 10.1097/icl.0000000000000578] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
20
|
Onaciu A, Munteanu RA, Moldovan AI, Moldovan CS, Berindan-Neagoe I. Hydrogels Based Drug Delivery Synthesis, Characterization and Administration. Pharmaceutics 2019; 11:E432. [PMID: 31450869 PMCID: PMC6781314 DOI: 10.3390/pharmaceutics11090432] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2019] [Revised: 08/02/2019] [Accepted: 08/12/2019] [Indexed: 02/06/2023] Open
Abstract
Hydrogels represent 3D polymeric networks specially designed for various medical applications. Due to their porous structure, they are able to swollen and to entrap large amounts of therapeutic agents and other molecules. In addition, their biocompatibility and biodegradability properties, together with a controlled release profile, make hydrogels a potential drug delivery system. In vivo studies have demonstrated their effectiveness as curing platforms for various diseases and affections. In addition, the results of the clinical trials are very encouraging and promising for the use of hydrogels as future target therapy strategies.
Collapse
Affiliation(s)
- Anca Onaciu
- Medfuture-Research Center for Advanced Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, Marinescu 23/Pasteur 4-6 Street, 400337 Cluj-Napoca, Romania
| | - Raluca Andrada Munteanu
- Medfuture-Research Center for Advanced Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, Marinescu 23/Pasteur 4-6 Street, 400337 Cluj-Napoca, Romania
| | - Alin Iulian Moldovan
- Medfuture-Research Center for Advanced Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, Marinescu 23/Pasteur 4-6 Street, 400337 Cluj-Napoca, Romania
- Department of Pharmaceutical Physics-Biophysics, Faculty of Pharmacy, "Iuliu Hațieganu" University of Medicine and Pharmacy, Pasteur 6 Street, 400349 Cluj-Napoca, Romania
| | - Cristian Silviu Moldovan
- Medfuture-Research Center for Advanced Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, Marinescu 23/Pasteur 4-6 Street, 400337 Cluj-Napoca, Romania
- Department of Pharmaceutical Physics-Biophysics, Faculty of Pharmacy, "Iuliu Hațieganu" University of Medicine and Pharmacy, Pasteur 6 Street, 400349 Cluj-Napoca, Romania
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, Marinescu 23 Street, 400337 Cluj-Napoca, Romania
| | - Ioana Berindan-Neagoe
- Medfuture-Research Center for Advanced Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, Marinescu 23/Pasteur 4-6 Street, 400337 Cluj-Napoca, Romania.
- Research Center for Functional Genomics, Biomedicine and Translational Medicine, "Iuliu Hațieganu" University of Medicine and Pharmacy, Marinescu 23 Street, 400337 Cluj-Napoca, Romania.
- The Oncology Institute "Prof Dr Ion Chiricuța", Republicii 34-36 Street, 400015 Cluj-Napoca, Romania.
| |
Collapse
|
21
|
Willcox MDP, Chen R, Kalaiselvan P, Yasir M, Rasul R, Kumar N, Dutta D. The Development of an Antimicrobial Contact Lens - From the Laboratory to the Clinic. Curr Protein Pept Sci 2019; 21:357-368. [PMID: 31429686 DOI: 10.2174/1389203720666190820152508] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 06/14/2019] [Accepted: 07/22/2019] [Indexed: 11/22/2022]
Abstract
Contact lens wear is generally safe and provides excellent vision. However, contact lens wear is often associated with the risk of developing ocular surface infection and inflammation, and in severe cases, the infection can result in loss of vision. Antimicrobial peptide-coated contact lenses have been made to help reduce the incidence of infection and inflammation. This paper reviews the research progress from conception, through the laboratory and preclinical tests to the latest information on clinical testing of an antimicrobial contact lens. We provide insights into the pathways followed and pitfalls that have been encountered. The journey has not always been linear or smooth, but has resulted in some of the first published clinical testing of antimicrobial peptide-coated contact lenses in humans. We hope this may help lead to the development and commercialisation of antimicrobial contact lenses in the future.
Collapse
Affiliation(s)
- Mark D P Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - R Chen
- School of Chemistry, University of New South Wales, Sydney, Australia
| | - P Kalaiselvan
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - M Yasir
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - R Rasul
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - N Kumar
- School of Chemistry, University of New South Wales, Sydney, Australia
| | - D Dutta
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
22
|
Biocidal Efficacy of a Hydrogen Peroxide Lens Care Solution Incorporating a Novel Wetting Agent. Eye Contact Lens 2019; 45:164-170. [PMID: 30138250 DOI: 10.1097/icl.0000000000000549] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the antimicrobial effects of CLEAR CARE, a 3% hydrogen peroxide (H2O2) solution formulated for simultaneous cleaning, daily protein removal, disinfection, and storage of soft (hydrophilic) hydrogel, silicone hydrogel, and gas-permeable contact lenses, and CLEAR CARE PLUS, consisting of the 3% H2O2 solution plus a novel wetting agent, polyoxyethylene-polyoxybutylene (EOBO-21). METHODS Three lots each of the 2 solutions were incubated with 5 compendial microorganisms required by the Food and Drug Administration (FDA) 510(k) and International Organization for Standardization (ISO) 14729 stand-alone procedures, 4 clinical isolates of Gram-positive and Gram-negative bacteria, and trophozoites and cysts of 2 Acanthamoeba strains that are associated with microbial keratitis. Microbial loads were evaluated after disinfection and neutralization. RESULTS Both solutions exceeded the FDA/ISO stand-alone primary criteria against Gram-positive and Gram-negative compendial bacteria, yeast, and mold after only 1.5-hr disinfection/neutralization. At the recommended minimum disinfection time, bacteria were reduced by 4.4 to 5.1 logs, yeast by 4.4 to 4.9 logs, and mold by 2.9 to 3.5 logs with and without organic soil. In addition, both solutions eliminated or effectively reduced populations of clinically relevant ocular bacterial isolates (4.5-5.0 logs), Acanthamoeba trophozoites (3.4-4.2 logs), and cysts (1.5-2.1 logs). CONCLUSION Both solutions eliminated or reduced populations of FDA/ISO compendial bacteria and fungi as well as clinically relevant microorganisms and Acanthamoeba trophozoites and cysts. The addition of EOBO-21 to the 3% H2O2 lens care solution had no impact on antimicrobial activity.
Collapse
|
23
|
Chao C, Akileswaran L, Cooke Bailey JN, Willcox M, Van Gelder R, Lakkis C, Stapleton F, Richdale K. Potential Role of Ocular Microbiome, Host Genotype, Tear Cytokines, and Environmental Factors in Corneal Infiltrative Events in Contact Lens Wearers. Invest Ophthalmol Vis Sci 2019; 59:5752-5761. [PMID: 30516819 PMCID: PMC6281277 DOI: 10.1167/iovs.18-24845] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Purpose The purpose of this study was to explore differences in genotype, ocular surface microbiome, tear inflammatory markers, and environmental and behavioral exposures in soft contact lens (SCL) wearers with and without a history of corneal infiltrative events (CIEs). Methods Nine SCL wearers with a recent CIE and nine age-, sex-, and SCL material- and modality-matched controls were enrolled. The Contact Lens Risk Survey, slit-lamp examination data, basal tears, conjunctival microbial cultures, and peripheral blood samples were collected. Tear inflammatory mediator concentrations, genomic DNA from swabs, and whole exome sequencing of blood samples were quantified. Results There were no marked differences in SCL wear behaviors or exposures between case and control subjects. Predominant organisms detected among case and control subjects were Staphylococcus, Propionibacterium, Streptococcus, and Corynebacterium. Marginally higher levels of Neisseria were found in three of nine cases but zero of nine control samples (P = 0.056). A potentially deleterious missense single nucleotide polymorphism (SNP) variant in IL-6 Signal Transducer (IL6ST) was found in seven of eight cases and zero of nine controls (rs2228046; P = 0.03). The concentration of tear IL-6 was significantly higher in cases (4.5 [range, 2.1 to 6.2] pg/mL) versus controls (3.5 [range, 2.5 to 6.6] Pg/mL; = 0.02). Conclusions Tear IL-6 concentration was higher, and SNP variants were detected in subjects with a history of CIEs compared with healthy controls. The synthesis, signaling, and ocular surface cytokine concentration of IL-6 may be related to susceptibility to CIE. A larger study population is required to further explore relationships between genetic variations, the ocular surface microbiome, inflammatory mediators, and environmental exposures.
Collapse
Affiliation(s)
- Cecilia Chao
- Tufts Medical Center, Center for Translational Ocular Immunology, Boston, Massachusetts, United States.,University of New South Wales School of Optometry and Vision Science, Kensington, New South Wales, Australia
| | - Lakshmi Akileswaran
- Department of Ophthalmology, University of Washington Medical School, Seattle, Washington, United States
| | - Jessica N Cooke Bailey
- Department of Population and Quantitative Health Sciences, Case Western Reserve University, Institute for Computational Biology, Cleveland, Ohio, United States
| | - Mark Willcox
- University of New South Wales School of Optometry and Vision Science, Kensington, New South Wales, Australia
| | - Russell Van Gelder
- Department of Ophthalmology, University of Washington Medical School, Seattle, Washington, United States
| | - Carol Lakkis
- Johnson & Johnson Vision Care, Inc., Jacksonville, Florida, United States
| | - Fiona Stapleton
- University of New South Wales School of Optometry and Vision Science, Kensington, New South Wales, Australia
| | - Kathryn Richdale
- University of Houston College of Optometry, Houston, Texas, United States
| |
Collapse
|
24
|
|
25
|
Antibacterial Activities of Lipopeptide (C 10)₂-KKKK-NH₂ Applied Alone and in Combination with Lens Liquids to Fight Biofilms Formed on Polystyrene Surfaces and Contact Lenses. Int J Mol Sci 2019; 20:ijms20020393. [PMID: 30658481 PMCID: PMC6358866 DOI: 10.3390/ijms20020393] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2018] [Revised: 01/09/2019] [Accepted: 01/14/2019] [Indexed: 01/08/2023] Open
Abstract
The widespread use of biomaterials such as contact lenses is associated with the development of biofilm-related infections which are very difficult to manage with standard therapies. The formation of bacterial biofilms on the surface of biomaterials is associated with increased antibiotic resistance. Owing to their promising antimicrobial potential, lipopeptides are being intensively investigated as novel antimicrobials. However, due to the relatively high toxicity exhibited by numerous compounds, a lot of attention is being paid to designing new lipopeptides with optimal biological activities. The principal aim of this study was to evaluate the potential ophthalmic application of lipopeptide (C10)2-KKKK-NH2. This lipopeptide was synthesized according to Fmoc chemistry using the solid-phase method. The antibiofilm activities of the lipopeptide, antibiotics used in ocular infections, and commercially available lens liquids were determined using the broth dilution method on polystyrene 96-well plates and contact lenses. Resazurin was applied as the cell-viability reagent. The effectiveness of the commercially available lens liquids supplemented with the lipopeptide was evaluated using the same method and materials. (C10)2-KKKK-NH2 exhibited stronger anti-biofilm properties compared to those of the tested conventional antimicrobials and showed the ability to enhance the activity of lens liquids at relatively low concentrations (4–32 mg/L). Estimation of the eye irritation potential of the lipopeptide using Toxtree software 2.6.13 suggests that the compound could be safely applied on the human eye. The results of performed experiments encourage further studies on (C10)2-KKKK-NH2 and its potential application in the prophylaxis of contact lens-related eye infections.
Collapse
|
26
|
A review of cosmetic contact lens infections. Eye (Lond) 2018; 33:78-86. [PMID: 30385879 DOI: 10.1038/s41433-018-0257-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Revised: 10/03/2018] [Accepted: 10/05/2018] [Indexed: 11/08/2022] Open
Abstract
This paper provides a comprehensive review of the existing literature surrounding cosmetic contact lens infections. In this paper, lens-related, dispensing-related and patient-related factors are examined in detail.
Collapse
|
27
|
Clinical Outcomes and Contact Lens Case Contamination Using a Povidone–Iodine Disinfection System. Eye Contact Lens 2018; 44 Suppl 1:S221-S227. [DOI: 10.1097/icl.0000000000000385] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
In Vitro Compatibility of Contact Lenses With Corneal Epithelial Cells. Eye Contact Lens 2018; 44 Suppl 1:S283-S290. [DOI: 10.1097/icl.0000000000000408] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
|
29
|
Comparative Analysis of Adverse Events From a Series of Proof-of-Principle Extended Wear Studies. Eye Contact Lens 2018; 45:88-92. [PMID: 30080693 DOI: 10.1097/icl.0000000000000546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
AIM A series of proof-of-principle extended wear (EW) contact lens studies were conducted to assess what effect different interventions had on adverse events (AEs). Comparative analysis of AEs across studies was conducted to determine whether some interventions were more effective at reducing inflammatory AEs. METHOD Multiple logistic regression analysis of AEs from 30-day EW studies each with a different intervention including (1) nightly replacement (NR) of lenses, (2) morning replacement (MR) of lenses, (3) instillation of prophylactic antibiotic drops (AB) each morning/evening, (4) daily lens cleaning (LC) each morning. All studies conducted at the same site using same lens type (lotrafilcon A) and EW schedule. RESULTS Comparison of the different interventions to the individual control groups showed no difference in significant corneal infiltrative event (CIE) or mechanical events. Replacing lenses nightly, during an EW schedule, had the highest incidence of significant CIEs (4.9% [NR] vs. 2.5% [MR] vs. 1.8% [AB] vs. 0% [LC]); however, adjusted logistic regression analysis of the combined control data compared with the individual interventions showed no difference in significant CIEs (P=0.086) or mechanical AEs (P=0.140). CONCLUSIONS Replacing lenses each night seemed to be inferior compared with the other interventions of replacing lenses each morning, daily lens cleaning, and daily antibiotic drop instillation during EW. The results of the collective studies and additional analysis suggest that overnight wear of contact lenses seems to create an adverse environment that remains, despite the various interventions intended to improve this adverse environment.
Collapse
|
30
|
Refractive Errors & Refractive Surgery Preferred Practice Pattern®. Ophthalmology 2018; 125:P1-P104. [DOI: 10.1016/j.ophtha.2017.10.003] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2017] [Accepted: 10/02/2017] [Indexed: 11/19/2022] Open
|
31
|
Steele KR, Szczotka-Flynn L. Epidemiology of contact lens-induced infiltrates: an updated review. Clin Exp Optom 2017; 100:473-481. [PMID: 28868803 DOI: 10.1111/cxo.12598] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2017] [Revised: 07/10/2017] [Accepted: 07/11/2017] [Indexed: 11/29/2022] Open
Abstract
Corneal infiltrative events (CIEs) are well established as a risk associated with soft contact lens wear. The incidence of symptomatic CIEs during extended soft lens wear ranges from 2.5 to six per cent; when asymptomatic CIEs are included, the incidence can be as high as 20-25 per cent. In daily soft lens wear, the annual incidence of symptomatic CIEs is about three per cent. There are various accepted methods of categorising CIEs, and a scoring system based on clinical signs and symptoms is a good approach to grade severity. Lens-related risk factors include extended wear, silicone hydrogel material, the use of multipurpose solutions, bacterial bioburden and reusable lenses. Recent studies report that daily disposable lenses reduce the risk of CIEs.
Collapse
Affiliation(s)
- Kelsy R Steele
- The Ohio State University College of Optometry, Columbus, Ohio, USA
| | - Loretta Szczotka-Flynn
- University Hospitals Eye Institute, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA.,Department of Ophthalmology and Visual Sciences, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
32
|
Carnt N, Samarawickrama C, White A, Stapleton F. The diagnosis and management of contact lens-related microbial keratitis. Clin Exp Optom 2017; 100:482-493. [PMID: 28815736 DOI: 10.1111/cxo.12581] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Revised: 05/22/2017] [Accepted: 05/27/2017] [Indexed: 01/10/2023] Open
Abstract
Contact lens-associated microbial keratitis poses a diagnostic dilemma for optometrists on two fronts. The distinction between sterile inflammation and microbial infection is often blurred. In addition, there is a requirement with nearly 50 per cent of the Australian and New Zealand optometric profession being therapeutically endorsed, to distinguish between cases of infection that can be managed in the community verses those that require escalation to public hospitals that have access to laboratory diagnostic tools and advanced imaging techniques, such as in vivo confocal microscopy. Pattern recognition and incorporation of knowledge of aetiology and risk factors assists optometrists to decide on optimal management strategies. Skilled optometrists will utilise emerging diagnostic and therapeutic technologies to ensure safe management strategies and better outcomes for these cases.
Collapse
Affiliation(s)
- Nicole Carnt
- School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia.,The Westmead Institute for Medical Research, The University of Sydney, Sydney, New South Wales, Australia
| | - Chameen Samarawickrama
- The Westmead Institute for Medical Research, The University of Sydney, Sydney, New South Wales, Australia
| | - Andrew White
- The Westmead Institute for Medical Research, The University of Sydney, Sydney, New South Wales, Australia
| | - Fiona Stapleton
- School of Optometry and Vision Science, The University of New South Wales, Sydney, New South Wales, Australia
| |
Collapse
|
33
|
Abstract
PURPOSE To determine whether mucin ball (MB) formation is protective against corneal infiltrative events (CIEs) as previously reported. METHODS Two hundred eighty-two eligible participants were enrolled at three sites in the USA. Participants began a 1-month continuous wear run-in period with high modulus lotrafilcon A lenses to assess their ability to form MBs (phase 1). Subsequently, they were stratified by this characteristic and randomized to balafilcon A or comfilcon A lenses for 7-day extended wear and followed for 1 year (phase 2). MB formation in each phase was defined as repeated presence of any MBs on a person level. Multivariable Cox proportional hazards regression was used to model the probability of a CIE as a function of MB formation in each phase and other covariates. RESULTS Of the 282 participants who entered phase 1, 218 of them entered the phase 2 randomized trial during which 33 CIEs occurred. Overall, 74%, 61%, and 79% of participants repeatedly produced MBs in lotrafilcon A, balafilcon A, and comfilcon A lenses, respectively. Early repeated MB presence in phase 1 with lotrafilcon A lenses significantly increased the rate of CIEs in phase 2 (12-month follow-up) by 466% (HR 4.66, 95% confidence interval 1.10-19.79, P = .0372). Repeated, longer-term MB presence during wear of balafilcon A or comfilcon A in phase 2 did not significantly reduce the incidence of CIEs; however, it significantly decreased the rate of CIEs by 62% (hazard ratio (HR) 0.380, 95% confidence interval 0.145-0.998, P = .0494). CONCLUSIONS The overarching hypothesis that MB formation is protective against CIEs throughout extended wear was not supported. Although a protective effect of longer-term MB presence on rate of CIEs was detected, early-onset MB formation substantially increased the hazard for CIE in subsequent wear with different lens types.
Collapse
|
34
|
Nie Y, Gross H, Zhong Y, Duerr F. Freeform optical design for a nonscanning corneal imaging system with a convexly curved image. APPLIED OPTICS 2017; 56:5630-5638. [PMID: 29047704 DOI: 10.1364/ao.56.005630] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Accepted: 06/09/2017] [Indexed: 05/28/2023]
Abstract
Most existing techniques that are typically used by specialists to image the cornea are based on point, slit, or annular scanning due to a narrow field of view. The difficulty in achieving a larger field of view comes from the convex shape of the human eyeball. Field curvature for a refractive imaging system with positive power is typically negative and thus a concave image surface. In order to view the full cornea and sclera with snapshot imaging, we calculate qualified two- and three-mirror solutions from Seidel aberration theory. A three-mirror solution is further optimized as a high-resolution off-axis imaging system using freeform surfaces, which can obtain a full-field tailored image shell without scanning. The lateral resolution on the cornea is about 10 μm with good modulation transfer function (MTF) and spot performance. To ease the assembly, a monolithic design is achieved with slightly lower resolution, leading to a potential mass production solution.
Collapse
|
35
|
Hinojosa JA, Patel NB, Zhu M, Robertson DM. Antimicrobial Efficacy of Contact Lens Care Solutions Against Neutrophil-Enhanced Bacterial Biofilms. Transl Vis Sci Technol 2017; 6:11. [PMID: 28473944 PMCID: PMC5412968 DOI: 10.1167/tvst.6.2.11] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 02/21/2017] [Indexed: 12/28/2022] Open
Abstract
Purpose Neutrophil-derived extracellular debris has been shown to accelerate bacterial biofilm formation on hydrogel and silicone hydrogel contact lens surfaces compared to lenses inoculated with bacteria alone. The purpose of this study was to evaluate the disinfection efficacy of four standard commercial contact lens cleaning regimens against neutrophil-enhanced bacterial biofilms formed on silicone hydrogel contact lenses. Methods Four reference strains were used: Pseudomonas aeruginosa,Serratia marcescens,Stenotrophomonas maltophilia, and Staphylococcus aureus. Human neutrophils were isolated from peripheral blood by venipuncture. Unworn Lotrafilcon B lenses were incubated overnight in each respective strain with stimulated neutrophils. Contact lenses were then cleaned using one of four contact lens care solutions according to manufacturer instructions. Bacterial viability was assessed by colony counts and confocal microscopy. Volume of residual debris on lens surfaces after cleaning was quantified using IMARIS software. Results All four solutions tested showed effective antimicrobial activity against each bacterial strain; however, substantial amounts of nonviable bacteria and cellular debris remained on the lens surface despite concomitant digital cleaning. Conclusions Necrotic cellular debris that accumulates under the posterior lens surface during wear of an inoculated contact lens is not fully removed during routine cleaning and disinfection. Translational Relevance The accumulation of residual cellular debris on the contact lens surface may contribute to new colonization of the lens and represents a significant risk factor for a contact lens–related adverse event. Additional studies are needed to correlate these findings with risk for corneal infiltrative and/or infectious events in a standard animal model.
Collapse
Affiliation(s)
- Jorge A Hinojosa
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Naiya B Patel
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Meifang Zhu
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Danielle M Robertson
- Department of Ophthalmology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
36
|
Kim DH, Kim MK, Wee WR. Unilateral Peripheral Sterile Infiltrates after Myopic Laser Epithelial Keratomileusis: Relationship with Postoperative Pain. KOREAN JOURNAL OF OPHTHALMOLOGY 2017; 31:86-87. [PMID: 28243028 PMCID: PMC5327179 DOI: 10.3341/kjo.2017.31.1.86] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Affiliation(s)
- Dong Hyun Kim
- Department of Ophthalmology, Gachon University Gil Medical Center, Incheon, Korea
| | - Mee Kum Kim
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Won Ryang Wee
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
37
|
Callahan D, Kovacs C, Lynch S, Rah M. Biocidal efficacy of multipurpose solutions against Gram-negative organisms associated with corneal infiltrative events. Clin Exp Optom 2017; 100:357-364. [PMID: 28194876 PMCID: PMC5516204 DOI: 10.1111/cxo.12509] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Revised: 09/09/2016] [Accepted: 11/06/2016] [Indexed: 12/22/2022] Open
Abstract
Background Because corneal infiltrative events (CIEs) may result from bacterial components on contact lenses, which can come from contaminated lens cases, we evaluated the biocidal efficacy of five multipurpose solutions against Gram‐negative commonly isolated and CIE‐associated organisms. Methods Of the multipurpose solutions tested, one contained polyhexamethylene biguanide (PHMB)/polyquaternium‐1 (PQ‐1; Bausch & Lomb Incorporated: Biotrue), one contained alexidine dihydrochloride (alexidine)/PQ‐1 (AMO: RevitaLens OcuTec) and three contained PQ‐1/myristamidopropyl dimethylamine (MAPD; Alcon: Opti‐Free PureMoist, PQ‐1/MAPD‐1; Opti‐Free RepleniSH, PQ‐1/MAPD‐2; Opti‐Free Express, PQ‐1/MAPD‐3). Challenge organisms were CIE‐associated Achromobacter xylosoxidans, Delftia acidovorans and Stenotrophomonas maltophilia at manufacturer‐recommended durations (stand‐alone), in lens cases without lenses (up to seven days) and in lens cases with etafilcon A lenses (up to 30 days). Results In stand‐alone testing against CIE‐associated organisms, PHMB/PQ‐1 and alexidine/PQ‐1 were significantly superior versus MAPD‐based multipurpose solutions against A. xylosoxidans (all p ≤ 0.01), D. acidovorans (all p ≤ 0.001) and S. maltophilia (all p ≤ 0.05). In lens cases, PHMB/PQ‐1 and alexidine/PQ‐1 achieved greater than 3‐log reductions against all challenge organisms at all times evaluated. PQ‐1/MAPD‐1 achieved a greater than 3‐log reduction against D. acidovorans at 24 hours; PQ‐1/MAPD‐1 and PQ‐1/MAPD‐3 achieved greater than 3‐log reductions at seven days against all organisms. In lens cases with lenses, PHMB/PQ‐1 and alexidine/PQ‐1 achieved greater than 3‐log reductions against all organisms at all times. PQ‐1/MAPD‐1 and PQ‐1/MAPD‐3 achieved greater than 3‐log reductions at seven or more days against all organisms. PQ‐1/MAPD‐2 did not achieve a greater than 3‐log reduction at any time; some regrowth was observed. Conclusions PHMB‐ and alexidine‐based multipurpose solutions demonstrated significantly greater biocidal activity compared with PQ‐1/MAPD‐based agents against Gram‐negative organisms commonly isolated and CIE‐associated pathogens.
Collapse
Affiliation(s)
| | | | - Shawn Lynch
- Bausch & Lomb Incorporated, Rochester, New York, USA
| | - Marjorie Rah
- Bausch & Lomb Incorporated, Rochester, New York, USA
| |
Collapse
|
38
|
The impact of lens care solutions on corneal epithelial changes during daily silicone hydrogel contact lens wear as measured by in vivo confocal microscopy. Cont Lens Anterior Eye 2017; 40:33-41. [DOI: 10.1016/j.clae.2016.11.006] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Revised: 11/09/2016] [Accepted: 11/11/2016] [Indexed: 11/22/2022]
|
39
|
Abstract
For many years, blepharitis and dry eye disease have been thought to be two distinct diseases, and evaporative dry eye distinct from aqueous insufficiency. In this treatise, we propose a new way of looking at dry eye, both evaporative and insufficiency, as the natural sequelae of decades of chronic blepharitis. Dry eye is simply the late form and late manifestation of one disease, blepharitis. We suggest the use of a new term in describing this one chronic disease, namely dry eye blepharitis syndrome (DEBS). Bacteria colonize the lid margin within a structure known as a biofilm. The biofilm allows for population densities that initiate quorum-sensing gene activation. These newly activated gene products consist of inflammatory virulence factors, such as exotoxins, cytolytic toxins, and super-antigens, which are then present for the rest of the patient’s life. The biofilm never goes away; it only thickens with age, producing increasing quantities of bacterial virulence factors, and thus, increasing inflammation. These virulence factors are likely the culprits that first cause follicular inflammation, then meibomian gland dysfunction, aqueous insufficiency, and finally, after many decades, lid destruction. We suggest that there are four stages of DEBS which correlate with the clinical manifestations of folliculitis, meibomitis, lacrimalitis, and finally lid structure damage evidenced by entropion, ectropion, and floppy eyelid syndrome. When one fully understands the structure and location of the glands within the lid, it becomes easy to understand this staged disease process. The longer a gland can resist the relentless encroachment of the invading biofilm, the longer it can maintain normal function. The stages depend purely on anatomy and years of biofilm presence. Dry eye now becomes a very easy disease to understand. We feel that dry eye should be treated and prevented by early and routine biofilm removal through electromechanical lid margin debridement.
Collapse
Affiliation(s)
| | - Henry D Perry
- Department of Ophthalmology, Nassau University Medical Center, Hofstra University School of Medicine, East Meadow, NY, USA
| |
Collapse
|
40
|
Maciejewska M, Bauer M, Neubauer D, Kamysz W, Dawgul M. Influence of Amphibian Antimicrobial Peptides and Short Lipopeptides on Bacterial Biofilms Formed on Contact Lenses. MATERIALS 2016; 9:ma9110873. [PMID: 28773992 PMCID: PMC5457276 DOI: 10.3390/ma9110873] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 09/22/2016] [Accepted: 10/20/2016] [Indexed: 12/28/2022]
Abstract
The widespread use of contact lenses is associated with several complications, including ocular biofilm-related infections. They are very difficult to manage with standard antimicrobial therapies, because bacterial growth in a biofilm is associated with an increased antibiotic resistance. The principal aim of this study was to evaluate the efficacy of antimicrobial peptides (AMPs) in eradication of bacterial biofilms formed on commercially available contact lenses. AMPs were synthesized according to Fmoc/tBu chemistry using the solid-phase method. Minimum inhibitory concentration (MIC) and minimum biofilm eradication concentration (MBEC) of the compounds were determined. Anti-biofilm activity of the antimicrobial peptides determined at different temperatures (25 °C and 37 °C) were compared with the effectiveness of commercially available contact lens solutions. All of the tested compounds exhibited stronger anti-biofilm properties as compared to those of the tested lens solutions. The strongest activity of AMPs was noticed against Gram-positive strains at a temperature of 25 °C. Conclusions: The results of our experiments encourage us toward further studies on AMPs and their potential application in the prophylaxis of contact lens-related eye infections.
Collapse
Affiliation(s)
- Magdalena Maciejewska
- Department of Inorganic Chemistry, Faculty of Pharmacy, Medical University of Gdansk, Gdansk 80-416, Poland.
- Pharmaceutical Laboratory, Avena SJ, Osielsko 86-031, Poland.
| | - Marta Bauer
- Department of Inorganic Chemistry, Faculty of Pharmacy, Medical University of Gdansk, Gdansk 80-416, Poland.
| | - Damian Neubauer
- Department of Inorganic Chemistry, Faculty of Pharmacy, Medical University of Gdansk, Gdansk 80-416, Poland.
| | - Wojciech Kamysz
- Department of Inorganic Chemistry, Faculty of Pharmacy, Medical University of Gdansk, Gdansk 80-416, Poland.
| | - Malgorzata Dawgul
- Department of Inorganic Chemistry, Faculty of Pharmacy, Medical University of Gdansk, Gdansk 80-416, Poland.
| |
Collapse
|
41
|
Abstract
Purpose: To document the time course and resolution of contact lens–related corneal infiltrative events (CIEs) comparing slit-lamp images with anterior segment ocular coherence tomography (AS-OCT) images. Methods: Six silicone hydrogel (SiHy) soft contact lens (SCL) wearers presenting with newly diagnosed symptomatic CIEs were monitored with slit-lamp images, detailed drawings, and AS-OCT until the resolution of the CIE. A final follow-up visit was completed 4 weeks after CIE resolution to determine whether scar formation was present. Positive controls were 2 SiHy SCL wearers with established (inactive) corneal scars, and negative controls were 2 SiHy SCL wearers with clear corneas. High- and low-contrast logMAR visual acuities were measured, and subjective symptom questionnaires were completed at all visits. Results: Clinical signs, vision, and symptoms improved in tandem with the resolution of the CIEs as measured by imaging methods. Calibrated measures of infiltrate width from a slit-lamp biomicroscope appear to be similar to calibrated images from AS-OCT. Conclusions: Although further studies are needed to develop standardized procedures, AS-OCT can be a useful tool to characterize the development, progression, and resolution of corneal infiltrates as an objective measure of resolution and scar formation.
Collapse
|
42
|
Xu C, He R, Xie B, Ismail M, Yao C, Luan J, Li X. Silicone hydrogels grafted with natural amino acids for ophthalmological application. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2016; 27:1354-68. [DOI: 10.1080/09205063.2016.1201916] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- Chen Xu
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Ruiyu He
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Binbin Xie
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Muhammad Ismail
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Chen Yao
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| | - Jie Luan
- Department of Ophthalmology, Zhongda Hospital Southeast University, Nanjing, China
| | - Xinsong Li
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing, China
| |
Collapse
|
43
|
Zimmerman AB, Emch AJ, Geldis J, Nixon GJ, Mitchell GL. Contact Lens Corneal Inflammatory Events in a University Population. Optom Vis Sci 2016; 93:42-9. [DOI: 10.1097/opx.0000000000000746] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
44
|
Effect of Daily Contact Lens Cleaning on Ocular Adverse Events during Extended Wear. Optom Vis Sci 2015; 92:157-66. [DOI: 10.1097/opx.0000000000000479] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
45
|
Risk factors for contact lens-induced papillary conjunctivitis associated with silicone hydrogel contact lens wear. Eye Contact Lens 2015; 40:117-22. [PMID: 24681609 DOI: 10.1097/icl.0000000000000019] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
BACKGROUND Contact lens-induced papillary conjunctivitis (CLPC) continues to be a major cause of dropout during extended wear of contact lenses. This retrospective study explores risk factors for the development of CLPC during extended wear of silicone hydrogel lenses. METHODS Data from 205 subjects enrolled in the Longitudinal Analysis of Silicone Hydrogel Contact Lens study wearing lotrafilcon A silicone hydrogel lenses for up to 30 days of continuous wear were used to determine risk factors for CLPC in this secondary analysis of the main cohort. The main covariates of interest included substantial lens-associated bacterial bioburden and topographically determined lens base curve-to-cornea fitting relationships. Additional covariates of interest included history of adverse events, time of year, race, education level, gender, and other subject demographics. Statistical analyses included univariate logistic regression to assess the impact of potential risk factors on the binary CLPC outcome and Cox proportional hazards regression to describe the impact of those factors on time-to-CLPC diagnosis. RESULTS Across 12 months of follow-up, 52 subjects (25%) experienced CLPC. No associations were found between the CLPC development and the presence of bacterial bioburden, lens-to-cornea fitting relationships, history of adverse events, gender, or race. Contact lens-induced papillary conjunctivitis development followed the same seasonal trends as the local peaks in environmental allergens. CONCLUSIONS Lens fit and biodeposits, in the form of lens-associated bacterial bioburden, were not associated with the development of CLPC during extended wear with lotrafilcon A silicone hydrogel lenses.
Collapse
|
46
|
|
47
|
Lin MC, Yuen J, Graham AD. Contact lens care solutions: a pilot study of ethnic differences in clinical signs and symptoms. Eye Contact Lens 2014; 40:191-9. [PMID: 24887209 PMCID: PMC4232463 DOI: 10.1097/icl.0000000000000034] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To determine whether Asian and white subjects differ in clinical signs or subjective symptoms in response to the use of different biguanide-preserved contact lens care solutions. METHODS Forty-two subjects (15 Asian and 27 white) wearing lotrafilcon B silicone hydrogel contact lenses used a preservative-free lens care solution bilaterally for 2 weeks, then used two biguanide-preserved solutions (solution 1: ReNu MPS; solution 2: AQuify MPS) contralaterally in randomly assigned eyes for 4 weeks. Comprehensive ocular surface examinations were performed and symptomatology questionnaires were administered every 2 weeks. Investigators were masked as to solution assignment during examinations, whereas subjects were not to avoid potential difficulties in compliance with the protocol. RESULTS With solution 1, most Asian and white subjects had grade 2 or greater corneal staining after 2 weeks (67% and 59%, respectively) and 4 weeks (60% and 67%, respectively). With solution 2, grade 2 or greater corneal staining occurred in 40% of Asians after 2 weeks and in 13% after 4 weeks, but in only 4% of whites after 2 weeks and 0% after 4 weeks. Whites reported significantly better average comfort (P=0.046) and less dryness (P<0.001) than did Asians. CONCLUSIONS Asians and whites differ in both ocular response to the use of contact lens care solutions and in reporting subjective symptoms. Racial and ethnic differences should be considered when evaluating and treating contact lens patients in a clinical setting.
Collapse
Affiliation(s)
- Meng C Lin
- Clinical Research Center, School of Optometry, University of California, Berkeley, CA
| | | | | |
Collapse
|
48
|
|
49
|
Jiang Y, Jacobs M, Bajaksouzian S, Foster AN, Debanne SM, Bielefeld R, Garvey M, Raghupathy S, Kern J, Szczotka-Flynn LB. Risk Factors for Microbial Bioburden During Daily Wear of Silicone Hydrogel Contact Lenses. Eye Contact Lens 2014; 40:148-56. [DOI: 10.1097/icl.0000000000000026] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
50
|
Abstract
PURPOSE Overnight lens wear is associated with increased lens contamination and risk of developing a corneal infiltrate or infectious event. Antibacterial lenses have been proposed as a potential strategy for reducing lens contamination. A proof-of-principle study was conducted to investigate what effect control of potential pathogens, through the use of antibiotic eye drops, would have on the incidence of corneal infiltrative events (CIEs) and on the ocular microbiota and lens contamination. METHODS This is a prospective, open-label, controlled, parallel-group, 1-month clinical study in which 241 subjects were dispensed with lotrafilcon A silicone hydrogel lenses for 30 days of continuous wear. Subjects were randomized into either test (moxifloxacin 0.5%) or control (rewetting solution) group. One drop was instilled into each eye on waking and before sleeping, while lenses were on-eye. Follow-ups were conducted after one night and 1 month. Lid margin swabs were taken at baseline and at 1 month and worn lenses were aseptically collected at 1 month. RESULTS The incidence of CIEs was not significantly different between the test (2.6%) and control (3.9%) groups (p = 0.72). Microorganism levels from the test group swabs were significantly lower than those from the control group (p = 0.001). Gram-positive bacteria were less frequently recovered from lower lid swabs from the test group (39.6% vs. 66.0% [p < 0.001], test vs. control, respectively) or from contact lens samples (1.9% vs. 10.5% [p = 0.015], test vs. control, respectively), but there was no difference in gram-negative bacteria (GNB). Corneal infiltrative events were associated with higher levels of lens contamination (p = 0.014) and contamination of lenses with GNB (CIE: 7.3% vs. 0.6% [p = 0.029], GNB contamination vs. no GNB contamination, respectively). DISCUSSION Twice-daily antibiotic instillation during continuous wear of lenses did not significantly influence the rate of inflammatory events. Corneal infiltrative events were associated with higher levels of lens contamination in general and with contamination by GNB specifically.
Collapse
|