Santonocito A, Zarcaro C, Zeitouni L, Ferrara F, Kapetas P, Helbich TH, Clauser P, Baltzer PAT. A head-to-head comparison of breast lesion's conspicuity at contrast-enhanced mammography and contrast-enhanced MRI. Eur Radiol 2024:10.1007/s00330-024-11195-4. [PMID: 39625504 DOI: 10.1007/s00330-024-11195-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 10/16/2024] [Accepted: 11/04/2024] [Indexed: 12/20/2024]
Abstract
PURPOSE Lesion conspicuity, the relative enhancement of a lesion compared to surrounding tissue, is a new descriptor in the ACR BI-RADS 2022 CEM supplement. We compared lesion conspicuity in contrast-enhanced mammography (CEM) and contrast-enhanced MRI (CE-MRI) in patients with suspicious breast lesions. MATERIALS AND METHODS IRB-approved retrospective study; three blinded readers rated 462 indeterminate or suspicious breast lesions in 388 patients (54.2 ± 11 years; range 30-90) who underwent CEM and CE-MRI from 2018 to 2022. Each lesion's conspicuity was scored from 1 to 5, with 5 indicating excellent conspicuity. Visual grading characteristics (VGC) analysis and area under the curve (AUC) were used for comparison, with sub-analyses for benign and malignant lesions. RESULTS VGC analysis showed a significant AUC of 0.670 to 0.723 (p < 0.001) favouring CE-MRI. No lesion enhancement (score 1) was observed in 16.2% of CE-MRI and 44.7% of CEM. Excellent conspicuity was seen in 29.6% of CE-MRI and 11.9% of CEM. Sub-analysis showed higher conspicuity on CE-MRI for both malignant (AUC 0.665 to 0.732, p < 0.001) and benign lesions (AUC 0.734 to 0.798, p < 0.001). CE-MRI showed higher lesion conspicuity compared to CEM both for non-mass lesions (0.656) and for mass lesions 0.605. CONCLUSION CE-MRI shows significantly higher conspicuity for benign and malignant breast lesions compared to CEM, especially for benign lesions. The low conspicuity of benign lesions on CEM may help reduce false positives in clinical practice. KEY POINTS Question Lesion conspicuity is a new descriptor for lesion enhancement according to the new CEM lexicon. Data correlating lesion conspicuity with malignancy likelihood are limited. Findings Lesion conspicuity is higher for contrast-enhanced-MRI than for contrast-enhanced mammography (CEM) for all lesions but significantly better for benign lesions. Clinical relevance The low conspicuity of benign lesions on CEM may reduce false-positive results, making it a valuable tool in breast cancer screening.
Collapse
Affiliation(s)
- Ambra Santonocito
- Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, General Hospital, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Calogero Zarcaro
- Department of Biomedicine, Neuroscience and Advanced Diagnostic (Bi.N.D.), University Hospital "Policlinico P. Giaccone", Via Del Vespro 129, 90127, Palermo, Italy
| | - Layla Zeitouni
- Department of Radiology Section of Breast Imaging King Faisal Specialist Hospital and Research Center Riyadh, Riyadh, Saudi Arabia
| | - Francesca Ferrara
- Catholic University of the Sacred Heart, Institute of Radiology, Largo A. Gemelli 8, 00168, Rome, Italy
| | - Panagiotis Kapetas
- Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, General Hospital, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
- Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, 300 E 66th Street, New York, NY, 10065, USA
| | - Thomas H Helbich
- Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, General Hospital, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Paola Clauser
- Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, General Hospital, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria
| | - Pascal A T Baltzer
- Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, General Hospital, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.
| |
Collapse
|
2
|
Depretto C, D'Ascoli E, Della Pepa G, Irmici G, De Berardinis C, Ballerini D, Bonanomi A, Ancona E, Ferranti C, Scaperrotta GP. Assessing the malignancy of suspicious breast microcalcifications: the role of contrast enhanced mammography. LA RADIOLOGIA MEDICA 2024; 129:855-863. [PMID: 38607514 DOI: 10.1007/s11547-024-01813-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 04/02/2024] [Indexed: 04/13/2024]
Abstract
PURPOSE To assess the role of contrast-enhanced mammography (CEM) in predicting the malignancy of breast calcifications. MATERIAL AND METHODS We retrospectively evaluated patients with suspicious calcifications (BIRADS 4) who underwent CEM and stereotactic vacuum-assisted biopsy (VAB) at our institution. We assessed the sensitivity (SE), specificity (SP), positive predictive value (PPV) and negative predictive value (NPV) of CEM in predicting malignancy of microcalcifications with a 95% confidence interval; we performed an overall analysis and a subgroup analysis stratified into group A-low risk (BIRADS 4a) and group B-medium/high risk (BIRADS 4b-4c). We then evaluated the correlation between enhancement and tumour proliferation index (Ki-67) for all malignant lesions. RESULTS Data from 182 patients with 184 lesions were collected. Overall the SE of CEM in predicting the malignancy of microcalcifications was 0.70, SP was 0.85, the PPV was 0.82, the NPV was 0.76 and AUC was 0.78. SE in group A was 0.89, SP was 0.89, PPV was 0.57, NPV was 0.98 and AUC was 0.75. SE in group B was 0.68, SP was 0.80, PPV was 0.87, NPV was 0.57 and AUC was 0.75. Among malignant microcalcifications that showed enhancement (N = 52), 61.5% had Ki-67 ≥ 20% and 38.5% had low Ki-67 values. Among the lesions that did not show enhancement (N = 22), 90.9% had Ki-67 < 20% and 9.1% showed high Ki-67 values 20%. CONCLUSIONS The absence of enhancement can be used as an indicative parameter for the absence of disease in cases of low-suspicious microcalcifications, but not in intermediate-high suspicious ones for which biopsy remains mandatory and can be used to distinguish indolent lesions from more aggressive neoplasms, with consequent reduction of overdiagnosis and overtreatment.
Collapse
Affiliation(s)
- Catherine Depretto
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | - Elisa D'Ascoli
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy.
| | - Gianmarco Della Pepa
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | - Giovanni Irmici
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | - Claudia De Berardinis
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | - Daniela Ballerini
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | - Alice Bonanomi
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | - Eleonora Ancona
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | - Claudio Ferranti
- Fondazione IRCCS Istituto Nazionale Dei Tumori Di Milano, Via Giacomo Venezian 1, 20133, Milan, Italy
| | | |
Collapse
|
3
|
Covington MF, Salmon S, Weaver BD, Fajardo LL. State-of-the-art for contrast-enhanced mammography. Br J Radiol 2024; 97:695-704. [PMID: 38374651 PMCID: PMC11027262 DOI: 10.1093/bjr/tqae017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 10/23/2023] [Accepted: 01/12/2024] [Indexed: 02/21/2024] Open
Abstract
Contrast-enhanced mammography (CEM) is an emerging breast imaging technology with promise for breast cancer screening, diagnosis, and procedural guidance. However, best uses of CEM in comparison with other breast imaging modalities such as tomosynthesis, ultrasound, and MRI remain inconclusive in many clinical settings. This review article summarizes recent peer-reviewed literature, emphasizing retrospective reviews, prospective clinical trials, and meta-analyses published from 2020 to 2023. The intent of this article is to supplement prior comprehensive reviews and summarize the current state-of-the-art of CEM.
Collapse
Affiliation(s)
- Matthew F Covington
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, 84112, United States
- Center for Quantitative Cancer Imaging, Huntsman Cancer Institute, Salt Lake City, UT, 84112, United States
| | - Samantha Salmon
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, 84112, United States
| | - Bradley D Weaver
- Spencer Fox Eccles School of Medicine, University of Utah, Salt Lake City, UT, 84112, United States
| | - Laurie L Fajardo
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, 84112, United States
| |
Collapse
|
4
|
Piccolo CL, Celli I, Bandini C, Tommasiello M, Sammarra M, Faggioni L, Cioni D, Beomonte Zobel B, Neri E. The Correlation between Morpho-Dynamic Contrast-Enhanced Mammography (CEM) Features and Prognostic Factors in Breast Cancer: A Single-Center Retrospective Analysis. Cancers (Basel) 2024; 16:870. [PMID: 38473232 DOI: 10.3390/cancers16050870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2023] [Revised: 02/11/2024] [Accepted: 02/16/2024] [Indexed: 03/14/2024] Open
Abstract
Breast cancer, a major contributor to female mortality globally, presents challenges in detection, prompting exploration beyond digital mammography. Contrast-Enhanced Mammography (CEM), integrating morphological and functional information, emerges as a promising alternative, offering advantages in cost-effectiveness and reduced anxiety compared to MRI. This study investigates CEM's correlation with breast cancer prognostic factors, encompassing histology, grade, and molecular markers. In a retrospective analysis involving 114 women, CEM revealed diverse lesion characteristics. Statistical analyses identified correlations between specific CEM features, such as spiculated margins and irregular shape, and prognostic factors like tumor grade and molecular markers. Notably, spiculated margins predicted lower grade and HER2 status, while irregular shape correlated with PgR and Ki-67 status. The study emphasizes CEM's potential in predicting breast cancer prognosis, shedding light on tumor behavior. Despite the limitations, including sample size and single-observer analysis, the findings advocate for CEM's role in stratifying breast cancers based on biological characteristics. CEM features, particularly spiculated margins, irregular shape, and enhancement dynamics, may serve as valuable indicators for personalized treatment decisions. Further research is crucial to validate these correlations and enhance CEM's clinical utility in breast cancer assessment.
Collapse
Affiliation(s)
- Claudia Lucia Piccolo
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Ilenia Celli
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Claudio Bandini
- Department of Translational Research, Academic Radiology, University of Pisa, 56126 Pisa, Italy
| | - Manuela Tommasiello
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Matteo Sammarra
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Lorenzo Faggioni
- Department of Translational Research, Academic Radiology, University of Pisa, 56126 Pisa, Italy
| | - Dania Cioni
- Department of Translational Research, Academic Radiology, University of Pisa, 56126 Pisa, Italy
| | - Bruno Beomonte Zobel
- Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 00128 Roma, Italy
- Operative Research Unit of Diagnostic Imaging, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Roma, Italy
| | - Emanuele Neri
- Department of Translational Research, Academic Radiology, University of Pisa, 56126 Pisa, Italy
| |
Collapse
|
5
|
Grażyńska A, Niewiadomska A, Owczarek AJ, Winder M, Hołda J, Zwolińska O, Barczyk-Gutkowska A, Lorek A, Kuźbińska A, Steinhof-Radwańska K. BIRADS 4 - Is it possible to downgrade lesions that do not enhance on recombinant contrast-enhanced mammography images? Eur J Radiol 2023; 167:111062. [PMID: 37643559 DOI: 10.1016/j.ejrad.2023.111062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 08/03/2023] [Accepted: 08/22/2023] [Indexed: 08/31/2023]
Abstract
PURPOSE Analysis of the morphology of lesions classified into the BI-RADS 4 category and assessment of the possibility of downgrade the BI-RADS category in those that did not show enhancement on recombinant contrast-enhanced mammography (CEM) images. METHOD The retrospective, single-center study included 528 patients who underwent a core needle biopsy performed from January 2017 to November 2022 due to a breast lesion classified as BI-RADS 4 on CEM. Patients' electronic records and imaging examinations were reviewed. Individual lesions were classified into the morphological categories of mass, non-mass, and microcalcifications. Sensitivity, specificity, positive as well as negative predictive values were calculated for the whole group and individual morphological categories. The influence of the lesions' diameter on the results was analyzed. RESULTS CEM NPV for the whole group was 93.9% (±95% CI: 90.0-96.4), for mass lesions 100% (±95% CI: 94.5-100), for non-mass lesions 97.8% (±95% CI: 87.0-99.9) and 87.9% (±95% CI: 80.3-93.0) for microcalcifications. Given that 230 out of 383 benign lesions were not contrast-enhancing, 60.1% of unnecessary CNBs would have been correctly avoided. CEM sensitivity for lesions < 20 mm was lower than for lesions ≥ 20 mm and was respectively 86.6% (±95% CI: 76.8-92.8) vs 94.6% (±95% CI: 86.0-98.2), respectively. CONCLUSION CEM is characterized by high sensitivity in the detection of malignant lesions in the case of lesions with mass and non-mass morphology. The high NPV for recombinant images suggests that in the case of these lesions, the lack of enhancement supports the benign nature of the lesion and may lead to a downgrade of the BI-RADS category.
Collapse
Affiliation(s)
- Anna Grażyńska
- Department of Radiology and Nuclear Medicine, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland.
| | - Agnieszka Niewiadomska
- Department of Radiology and Nuclear Medicine, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland
| | - Aleksander J Owczarek
- Department of Pathophysiology, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland
| | - Mateusz Winder
- Department of Radiology and Nuclear Medicine, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland
| | - Jakub Hołda
- Department of Radiology and Nuclear Medicine, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland; Department of Anatomy, Jagiellonian University Medical College, Kopernika 12, 31-034 Cracow, Poland
| | - Olga Zwolińska
- Department of Radiology and Nuclear Medicine, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland
| | - Anna Barczyk-Gutkowska
- Department of Radiology and Nuclear Medicine, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland
| | - Andrzej Lorek
- Department of Oncological Surgery, Prof. Kornel Gibiński Independent Public Central Clinical Hospital, Ceglana 35, 40-514 Katowice, Poland
| | - Aleksandra Kuźbińska
- Department of Pathomorfology, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland
| | - Katarzyna Steinhof-Radwańska
- Department of Radiology and Nuclear Medicine, Medical University of Silesia, Medyków 14, 40-752 Katowice, Poland.
| |
Collapse
|
6
|
Giambersio E, Depretto C, Trimboli RM, Di Leo G, D'Ascoli E, Della Pepa G, Irmici G, Rabiolo L, Scaperrotta GP. Utility of detection of breast calcifications with integrated real-time radiography system (IRRS) during digital breast tomosynthesis (DBT)-guided vacuum assisted biopsy (VAB): initial single-center experience. LA RADIOLOGIA MEDICA 2023:10.1007/s11547-023-01636-3. [PMID: 37115391 DOI: 10.1007/s11547-023-01636-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 04/20/2023] [Indexed: 04/29/2023]
Abstract
PURPOSE To determine whether the presence of calcifications in specimens collected during stereotactic-guided vacuum-assisted breast biopsies (VABB) is sufficient to ascertain their adequacy for final diagnosis at pathology. MATERIALS AND METHODS Digital breast tomosynthesis (DBT)-guided VABBs were performed on 74 patients with calcifications as target. Each biopsy consisted of the collection of 12 samplings with a 9-gauge needle. This technique was integrated with a real-time radiography system (IRRS) which allowed the operator to determine whether calcifications were included in the specimens at the end of each of the 12 tissue collections through the acquisition of a radiograph of every sampling. Calcified and non-calcified specimens were separately sent to pathology and evaluated. RESULTS A total of 888 specimens were retrieved, 471 containing calcifications and 417 without. In 105 (22.2%) samples out of 471 with calcifications cancer was detected, while the remaining 366 (77.7%) were non-cancerous. Out of 417 specimens without calcifications 56 (13.4%) were cancerous, whereas 361 (86.5%) were non-cancerous. Seven hundred and twenty-seven specimens out of all 888 were cancer-free (81.8%, 95%CI 79-84%). CONCLUSION Although there is a statistical significative difference between calcified and non-calcified samples and the detection of cancer (p < 0.001), our study shows that the sole presence of calcifications in the specimens is not sufficient to determine their adequacy for final diagnosis at pathology because non-calcified samples can be cancerous and vice-versa. Ending biopsies when calcifications are first detected through IRRS could lead to false negative results.
Collapse
Affiliation(s)
- Emilia Giambersio
- Postgraduate School in Radiodiagnostics, Università degli Studi Di Milano, Via Festa del Perdono 7, 20122, Milan, Italy.
| | - Catherine Depretto
- Breast Imaging Unit, IRCCS Istituto Nazionale dei Tumori, Via Venezian 1, 20133, Milan, Italy
| | | | - Giovanni Di Leo
- Radiology Unit, IRCCS Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese (Milan), Italy
| | - Elisa D'Ascoli
- Postgraduate School in Radiodiagnostics, Università degli Studi Di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Gianmarco Della Pepa
- Postgraduate School in Radiodiagnostics, Università degli Studi Di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Giovanni Irmici
- Postgraduate School in Radiodiagnostics, Università degli Studi Di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Lidia Rabiolo
- Section of Radiological Sciences, Department of Biomedicine, Neuroscience and Advanced Diagnostics, Università degli Studi di Palermo, Via del Vespro 127, 90127, Palermo, Italy
| | | |
Collapse
|
7
|
Vasselli F, Fabi A, Ferranti FR, Barba M, Botti C, Vidiri A, Tommasin S. How Dual-Energy Contrast-Enhanced Spectral Mammography Can Provide Useful Clinical Information About Prognostic Factors in Breast Cancer Patients: A Systematic Review of Literature. Front Oncol 2022; 12:859838. [PMID: 35941874 PMCID: PMC9355886 DOI: 10.3389/fonc.2022.859838] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Accepted: 05/27/2022] [Indexed: 12/24/2022] Open
Abstract
Introduction In the past decade, a new technique derived from full-field digital mammography has been developed, named contrast-enhanced spectral mammography (CESM). The aim of this study was to define the association between CESM findings and usual prognostic factors, such as estrogen receptors, progesterone receptors, HER2, and Ki67, in order to offer an updated overview of the state of the art for the early differential diagnosis of breast cancer and following personalized treatments. Materials and Methods According to the PRISMA guidelines, two electronic databases (PubMed and Scopus) were investigated, using the following keywords: breast cancer AND (CESM OR contrast enhanced spectral mammography OR contrast enhanced dual energy mammography) AND (receptors OR prognostic factors OR HER2 OR progesterone OR estrogen OR Ki67). The search was concluded in August 2021. No restriction was applied to publication dates. Results We obtained 28 articles from the research in PubMed and 114 articles from Scopus. After the removal of six replicas that were counted only once, out of 136 articles, 37 articles were reviews. Eight articles alone have tackled the relation between CESM imaging and ER, PR, HER2, and Ki67. When comparing radiological characterization of the lesions obtained by either CESM or contrast-enhanced MRI, they have a similar association with the proliferation of tumoral cells, as expressed by Ki-67. In CESM-enhanced lesions, the expression was found to be 100% for ER and 77.4% for PR, while moderate or high HER2 positivity was found in lesions with non-mass enhancement and with mass closely associated with a non-mass enhancement component. Conversely, the non-enhancing breast cancer lesions were not associated with any prognostic factor, such as ER, PR, HER2, and Ki67, which may be associated with the probability of showing enhancement. Radiomics on CESM images has the potential for non-invasive characterization of potentially heterogeneous tumors with different hormone receptor status. Conclusions CESM enhancement is associated with the proliferation of tumoral cells, as well as to the expression of estrogen and progesterone receptors. As CESM is a relatively young imaging technique, a few related works were found; this may be due to the “off-label” modality. In the next few years, the role of CESM in breast cancer diagnostics will be more thoroughly investigated.
Collapse
Affiliation(s)
- Federica Vasselli
- Radiology and Diagnostic Imaging, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Alessandra Fabi
- Precision Medicine in Breast Cancer Unit, Fondazione Policlinico Universitario A. Gemelli, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Rome, Italy
| | - Francesca Romana Ferranti
- Radiology and Diagnostic Imaging, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Maddalena Barba
- Division of Medical Oncology 2, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Claudio Botti
- Division of Breast Surgery, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
| | - Antonello Vidiri
- Radiology and Diagnostic Imaging, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Regina Elena National Cancer Institute, Rome, Italy
- *Correspondence: Antonello Vidiri,
| | - Silvia Tommasin
- Human Neuroscience Department, Sapienza University of Rome, Rome, Italy
- Neuroimmunology Unit, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Fondazione Santa Lucia, Rome, Italy
| |
Collapse
|
8
|
Cozzi A, Magni V, Zanardo M, Schiaffino S, Sardanelli F. Contrast-enhanced Mammography: A Systematic Review and Meta-Analysis of Diagnostic Performance. Radiology 2021; 302:568-581. [PMID: 34904875 DOI: 10.1148/radiol.211412] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background Contrast-enhanced mammography (CEM) is a promising technique for breast cancer detection, but conflicting results have been reported in previous meta-analyses. Purpose To perform a systematic review and meta-analysis of CEM diagnostic performance considering different interpretation methods and clinical settings. Materials and Methods The MEDLINE, EMBASE, Web of Science, and Cochrane Library databases were systematically searched up to July 15, 2021. Prospective and retrospective studies evaluating CEM diagnostic performance with histopathology and/or follow-up as the reference standard were included. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 tool. Summary diagnostic odds ratio and area under the receiver operating characteristic curve were estimated with the hierarchical summary receiver operating characteristic (HSROC) model. Summary estimates of sensitivity and specificity were obtained with the hierarchical bivariate model, pooling studies with the same image interpretation approach or focused on the same findings. Heterogeneity was investigated through meta-regression and subgroup analysis. Results Sixty studies (67 study parts, 11 049 CEM examinations in 10 605 patients) were included. The overall area under the HSROC curve was 0.94 (95% CI: 0.91, 0.96). Pooled diagnostic odds ratio was 55.7 (95% CI: 42.7, 72.7) with high heterogeneity (τ2 = 0.3). At meta-regression, CEM interpretation with both low-energy and recombined images had higher sensitivity (95% vs 94%, P < .001) and specificity (81% vs 71%, P = .03) compared with recombined images alone. At subgroup analysis, CEM showed a 95% pooled sensitivity (95% CI: 92, 97) and a 78% pooled specificity (95% CI: 66, 87) from nine studies in patients with dense breasts, while in 10 studies on mammography-detected suspicious findings, CEM had a 92% pooled sensitivity (95% CI: 89, 94) and an 84% pooled specificity (95% CI: 73, 91). Conclusion Contrast-enhanced mammography demonstrated high performance in breast cancer detection, especially with joint interpretation of low-energy and recombined images. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Bahl in this issue.
Collapse
Affiliation(s)
- Andrea Cozzi
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Veronica Magni
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Moreno Zanardo
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Simone Schiaffino
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| | - Francesco Sardanelli
- From the Department of Biomedical Sciences for Health, Università degli Studi di Milano, Via Luigi Mangiagalli 31, 20133 Milan, Italy (A.C., V.M., M.Z., F.S.); and Unit of Radiology, IRCCS Policlinico San Donato, San Donato Milanese, Italy (S.S., F.S.)
| |
Collapse
|
9
|
Woodard S, Murray A. Contrast-Enhanced Mammography: Reviewing the Past and Looking to the Future. Semin Roentgenol 2021; 57:126-133. [DOI: 10.1053/j.ro.2021.12.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2021] [Revised: 12/12/2021] [Accepted: 12/13/2021] [Indexed: 01/17/2023]
|
10
|
The diagnostic value of contrast-enhanced 2D mammography in everyday clinical use. Sci Rep 2021; 11:22224. [PMID: 34782698 PMCID: PMC8593172 DOI: 10.1038/s41598-021-01622-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Accepted: 10/28/2021] [Indexed: 11/09/2022] Open
Abstract
Contrast-enhanced mammography (CEM) has shown to be superior to full-field digital mammography (FFDM), but current results are dominated by studies performed on systems by one vendor. Information on diagnostic accuracy of other CEM systems is limited. Therefore, we aimed to evaluate the diagnostic performance of CEM on an alternative vendor’s system. We included all patients who underwent CEM in one hospital in 2019, except those with missing data or in whom CEM was used as response monitoring tool. Three experienced breast radiologists scored the low-energy images using the BI-RADS classification. Next, the complete CEM exams were scored similarly. Histopathological results or a minimum of one year follow-up were used as reference standard. Diagnostic performance and AUC were calculated and compared between low-energy images and the complete CEM examination, for all readers independently as well as combined. Breast cancer was diagnosed in 23.0% of the patients (35/152). Compared to low-energy images, overall CEM sensitivity increased from 74.3 to 87.6% (p < 0.0001), specificity from 87.8 to 94.6% (p = 0.0146). AUC increased from 0.872 to 0.957 (p = 0.0001). Performing CEM on the system tested, showed that, similar to earlier studies mainly performed on another vendor’s systems, both sensitivity and specificity improved when compared to FFDM.
Collapse
|