1
|
Belanger BL, Morrish R, McClarty D, Barnstable C, Muir W, Ghazizadeh S, Eesa M, Fiorella D, Wong JH, Sadasivan C, Mitha AP. In vitro flow diversion effect of the ReSolv stent with the shelf technique in a bifurcation aneurysm model. J Neurointerv Surg 2024; 16:296-301. [PMID: 37188503 DOI: 10.1136/jnis-2022-020023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 04/17/2023] [Indexed: 05/17/2023]
Abstract
BACKGROUND Flow-diverting stents are not currently indicated for the treatment of bifurcation aneurysms, and some case series have demonstrated low occlusion rates, possibly due to a lack in neck coverage. The ReSolv stent is a unique hybrid metal/polymer stent that can be deployed with the shelf technique in order to improve neck coverage. METHODS A Pipeline, unshelfed ReSolv, and shelfed ReSolv stent were deployed in the left-sided branch of an idealized bifurcation aneurysm model. After determining stent porosity, high-speed digital subtraction angiography runs were acquired under pulsatile flow conditions. Time-density curves were created using two region of interest (ROI) paradigms (total aneurysm and left/right), and four parameters were extracted to characterize flow diversion performance. RESULTS The shelfed ReSolv stent demonstrated better aneurysm outflow alterations compared to the Pipeline and unshelfed ReSolv stent when using the total aneurysm as the ROI. On the left side of the aneurysm, there was no significant difference between the shelfed ReSolv stent and the Pipeline. On the right side of the aneurysm, however, the shelfed ReSolv stent had a significantly better contrast washout profile than the unshelfed ReSolv stent and the Pipeline stent. CONCLUSIONS The ReSolv stent with the shelf technique demonstrates the potential to improve flow diversion outcomes for bifurcation aneurysms. Further in vivo testing will help to determine whether the additional neck coverage leads to better neointimal scaffolding and long-term aneurysm occlusion.
Collapse
Affiliation(s)
- Brooke L Belanger
- Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
| | - Rosalie Morrish
- Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
| | - Davis McClarty
- Department of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Colette Barnstable
- Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
| | - Warren Muir
- Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
| | - Soheil Ghazizadeh
- Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, Canada
| | - Muneer Eesa
- Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
| | - David Fiorella
- Department of Neurosurgery, Stony Brook University, Stony Brook, New York, USA
| | - John H Wong
- Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
| | - Chandar Sadasivan
- Department of Neurosurgery, Stony Brook University, Stony Brook, New York, USA
| | - Alim P Mitha
- Department of Clinical Neurosciences, University of Calgary, Foothills Medical Centre, Calgary, Alberta, Canada
- Department of Biomedical Engineering, University of Calgary, Calgary, Alberta, Canada
| |
Collapse
|
2
|
Zhang Z, Albadawi H, Fowl RJ, Mayer JL, Chong BW, Oklu R. Treatment of Ruptured Wide-Necked Aneurysms using a Microcatheter Injectable Biomaterial. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2305868. [PMID: 37579579 PMCID: PMC10843457 DOI: 10.1002/adma.202305868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2023] [Revised: 08/03/2023] [Indexed: 08/16/2023]
Abstract
Ruptured wide-neck aneurysms (WNAs), especially in a setting of coagulopathy, are associated with significant morbidity and mortality. It is shown that by trapping a sub-millimeter clinical catheter inside the aneurysm sac using a flow diverter stent (FDS), instant hemostasis can be achieved by filling the aneurysm sac using a novel biomaterial, rescuing catastrophic bleeding in large-animal models. Multiple formulations of a biomaterial comprising gelatin, nanoclay (NC), and iohexol are developed, optimized, and extensively tested in vitro to select the lead candidate for further testing in vivo in murine, porcine, and canine models of WNAs, including in a subset with aneurysm rupture. The catheter-injectable and X-ray visible versions of the gel embolic agent (GEA) with the optimized mechanical properties outperform control groups, including a subset that receive a clinically used liquid embolic (Onyx, Medtronic), with and without aneurysm rupture. A combinatorial approach to ruptured WNAs with GEA and FDS may change the standard of medical practice and save lives.
Collapse
Affiliation(s)
- Zefu Zhang
- Division of Vascular & Interventional Radiology, Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259. USA
| | - Hassan Albadawi
- Division of Vascular & Interventional Radiology, Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259. USA
| | - Richard J. Fowl
- Chair Emeritus, Division of Vascular and Endovascular Surgery, Emeritus Professor of Surgery, Mayo Clinic, 5777 East Mayo Blvd., Phoenix, Arizona 85054, USA
| | - Joseph L. Mayer
- Division of Vascular & Interventional Radiology, Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259. USA
| | - Brian W. Chong
- Department of Neurological Surgery and Radiology Mayo Clinic, 5777 East Mayo Blvd., Phoenix, Arizona 85054, USA
| | - Rahmi Oklu
- Division of Vascular & Interventional Radiology, Laboratory for Patient Inspired Engineering, Mayo Clinic, 13400 East Shea Blvd., Scottsdale, Arizona 85259. USA
| |
Collapse
|
3
|
King RM, Peker A, Anagnostakou V, Raskett CM, Arends JM, Dixit HG, Ughi GJ, Puri AS, Gounis MJ, Shazeeb MS. High-frequency optical coherence tomography predictors of aneurysm occlusion following flow diverter treatment in a preclinical model. J Neurointerv Surg 2023; 15:919-923. [PMID: 36002288 DOI: 10.1136/jnis-2022-019275] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Accepted: 08/12/2022] [Indexed: 12/17/2022]
Abstract
BACKGROUND High-frequency optical coherence tomography (HF-OCT) is an intravascular imaging method that allows for volumetric imaging of flow diverters in vivo. OBJECTIVE To examine the hypothesis that a threshold for both volume and area of communicating malapposition can be predictive of early aneurysm occlusion. METHODS Fifty-two rabbits underwent elastase aneurysm formation, followed by treatment with a flow diverter. At the time of implant, HF-OCT was acquired to study the rate and degree of communicating malapposition. Treated aneurysms were allowed to heal for either 90 or 180 days and euthanized following catheter angiography. Healing was dichotomized into aneurysm remnant or neck remnant/complete occlusion. Communicating malapposition was measured by HF-OCT using a semi-automatic algorithm able to detect any points where the flow diverter was more than 50 µm from the vessel wall. This was then summed across image slices to either a volume or area. Finally, a subsampled population was used to train a statistical classifier for the larger dataset. RESULTS No difference in occlusion rate was found between device type or follow-up time (p=0.28 and p=0.67, respectively). Both volume and area of malapposition were significantly lower in aneurysms with a good outcome (p<0.001, both). From the statistical model, a volume of less than 0.56 mm3 or a normalized area less than 0.69 as quantified by HF-OCT was predictive of occlusion (p<0.001, each). CONCLUSIONS HF-OCT allows for measurements of both volume and area of malapposition and, from these measurements, an accurate prediction for early aneurysm occlusion can be made.
Collapse
Affiliation(s)
- Robert M King
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
| | - Ahmet Peker
- Department of Radiology, Koc University Hospital, Istanbul, Turkey
| | - Vania Anagnostakou
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
| | - Christopher M Raskett
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
| | - Jennifer M Arends
- Research and Development, Stryker Neurovascular, Fremont, California, USA
| | - Harish G Dixit
- Research and Development, Stryker Neurovascular, Fremont, California, USA
| | - Giovanni J Ughi
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
| | - Ajit S Puri
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
| | - Matthew J Gounis
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
- Department of Radiology, Image Processing & Analysis Core (iPAC), University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
| | - Mohammed Salman Shazeeb
- Department of Radiology, New England Center for Stroke Research, University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
- Department of Radiology, Image Processing & Analysis Core (iPAC), University of Massachusetts Chan Medical School, Worcester, Massachusetts, USA
| |
Collapse
|
4
|
Pravdivtseva MS, Pravdivtsev AN, Peters S, Hensler J, Larsen N, Hövener JB, Jansen O, Wodarg F. The effect of the size of the new contour neurovascular device for altering intraaneurysmal flow. Interv Neuroradiol 2023:15910199221145985. [PMID: 36594503 DOI: 10.1177/15910199221145985] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND Recently, a novel intrasaccular device (contour neurovascular system, contour) was introduced to treat intracranial aneurysms. Contour is placed at thе aneurysm neck and reduces the intraaneurysmal blood inflow. Contour comes in a range of sizes to target different aneurysms. The efficiency of altering flow with contour and the effect of device size have not yet been investigated. Therefore, we studied the effect of the device size with patient-based aneurysm models using 2D digital subtraction angiography (DSA). METHODS Three patient-based aneurysm models with necks ranging from 2.7 to 9.7 mm were produced, providing standardized testing conditions. Contours with diameters of 5, 11, and 14 mm were implanted into the models, four of each size. 2D DSA images were acquired before and after implanting contour (15 frames/s, manual contrast injection). After injecting angiographic contrast agent, the DSA signal was recorded over time to calculate the contrast washout time (WOT), which is a measure of flow diversion efficiency. RESULTS All contour devices caused contrast agent stasis and increased WOT in aneurysm sac (p-value = 0.0005). The median relative WOT was largest for 5-mm contour (6.6 ± 3.2) and similar for 11-mm contour (3.4 ± 2.6) and 14-mm contour (3.2 ± 3.8). The implantation procedure might affect WOT values even for contours of the same size; the overall relative WOT ranged between 1.5 and 10.89. CONCLUSION The 5-mm contour showed the longest WOT value in our study, while no apparent difference between 11-mm contour and 14-mm contour was found.
Collapse
Affiliation(s)
- Mariya S Pravdivtseva
- Department of Radiology and Neuroradiology, Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), 54186University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| | - Andrey N Pravdivtsev
- Department of Radiology and Neuroradiology, Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), 54186University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| | - Sönke Peters
- Department of Radiology and Neuroradiology, 9179University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Johannes Hensler
- Department of Radiology and Neuroradiology, 9179University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Naomi Larsen
- Department of Radiology and Neuroradiology, 9179University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Jan-Bernd Hövener
- Department of Radiology and Neuroradiology, Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), 54186University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| | - Olav Jansen
- Department of Radiology and Neuroradiology, 9179University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| | - Fritz Wodarg
- Department of Radiology and Neuroradiology, 9179University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany
| |
Collapse
|
5
|
Marfoglio S, Kovarovic B, Fiorella DJ, Sadasivan C. A novel angiographic method to estimate arterial blood flow rates using contrast reflux: Effect of injection parameters. Med Phys 2023; 50:259-273. [PMID: 36030369 DOI: 10.1002/mp.15948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 07/20/2022] [Accepted: 08/10/2022] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Contrast reflux, which is the retrograde movement of contrast against flow direction, is commonly observed during angiography. Despite a vast body of literature on angiography, the hemodynamic factors affecting contrast reflux have not been studied. Numerous methods have been developed to extract flow from angiography, but the reliability of these methods is not yet sufficient to be of routine clinical use. PURPOSE To evaluate the effect of baseline blood flow rates and injection conditions on the extent of contrast reflux. To estimate arterial flow rates based on measurement of contrast reflux length. MATERIALS AND METHODS Iodinated contrast was injected into an idealized tube as well as a physiologically accurate model of the cervico-cerebral vasculature. A total of 194 high-speed angiograms were acquired under varying "blood" flow rates and injection conditions (catheter size, injection rate, and injection time). The length of contrast reflux was compared to the input variables and to dimensionless fluid dynamics parameters at the catheter-tip. Arterial blood flow rates were estimated using contrast reflux length as well as a traditional transit-time method and compared to measured flow rates. RESULTS Contrast reflux lengths were significantly affected by contrast injection rate (p < 0.0001), baseline blood flow rate (p = 0.0004), and catheter size (p = 0.04), but not by contrast injection time (p = 0.4). Reflux lengths were found to be correlated to dimensionless fluid dynamics parameters by an exponential function (R2 = 0.6-0.99). When considering the entire dataset in unison, flow estimation errors with the reflux-length method (39% ± 33%) were significantly higher (p = 0.003) than the transit-time method (33% ± 36%). However, when subgrouped by catheter, the error with the reflux-length method was substantially reduced and was significantly lower (14% ± 14%, p < 0.0001) than the transit-time method. CONCLUSION Results show correlations between contrast reflux length and baseline hemodynamic parameters that have not been reported previously. Clinically relevant blood flow rate estimation is feasible by simple measurement of reflux length. In vivo and clinical studies are required to confirm these correlations and to refine the methodology of estimating blood flow by reflux.
Collapse
Affiliation(s)
- Samantha Marfoglio
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA
| | - Brandon Kovarovic
- Department of Biomedical Engineering, Stony Brook University, Stony Brook, New York, USA
| | - David J Fiorella
- Department of Neurosurgery, Stony Brook University Medical Center, Stony Brook, New York, USA
| | - Chander Sadasivan
- Department of Neurosurgery, Stony Brook University Medical Center, Stony Brook, New York, USA
| |
Collapse
|
6
|
Simgen A, Weyrich A, Dietrich P, Roumia S, Mühl-Benninghaus R, Yilmaz U, Reith W, Kettner M. Treatment of Wide-Necked Cerebral Aneurysms Using the WEB Device Including Flow Alteration Assessment With Color-Coded Imaging: A Single Center Experience. World Neurosurg X 2022; 17:100143. [PMCID: PMC9626383 DOI: 10.1016/j.wnsx.2022.100143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/27/2022] [Indexed: 11/05/2022] Open
Abstract
Objective The Woven EndoBridge (WEB) device (MicroVention, Tustin, CA) has extended the treatment of cerebral aneurysms. Despite the fact that the WEB device has shown promising clinical results, little is known about the caused intra-aneurysmal flow alterations. Here we present our clinical experience with the WEB, including examining various syngo iFlow (Siemens AG, Erlangen, Germany) parameters to predict aneurysm occlusion. Methods We reviewed the data from patients with unruptured cerebral aneurysms treated with a WEB device between 2016 and 2020. Aneurysm occlusion and complications were assessed. Furthermore, different quantitative criteria were evaluated using syngo iFlow after digital subtraction angiography. Results A total of 26 patients hosting 26 cerebral aneurysms met the inclusion criteria. Follow-up was available for 21 patients, with a mean of 7.3 ± 6.3 months. A total of 71.4% (n = 15) of the aneurysms included were located in the anterior and 28.6% (n = 6) in the posterior circulation. Adequate aneurysm occlusion was achieved in 85.7% (n = 18). The iFlow parameters for reduced aneurysm outflow (ID-R) differed significantly from the parameters for reduced inflow (PI-R and PI-D) (P < 0.001). The parameters did not differ significantly between adequately and insufficiently occluded aneurysms. Only a trend towards a lower ID-R of insufficiently occluded aneurysms was observed (P = 0.063), indicating a potential predictive value for insufficient aneurysmal outflow. There was no treatment-related morbidity or mortality. Conclusions The applied syngo iFlow parameters confirmed that flow changes induced by the WEB device significantly affect outflow compared to inflow and have potential predictive value for adequate aneurysm occlusion.
Collapse
Key Words
- cerebral aneurysm
- syngo iflow
- web
- 2d, 2-dimensional
- boss, beaujon occlusion scale score
- cfd, computational fluid dynamics
- dsa, digital subtraction angiography
- id, intensity decrease
- id-r, intensity decrease ratio
- mrs, modified rankin scale
- pi, peak intensity
- pi-d, peak intensity delay
- pi-r, peak intensity ratio
- roi, region of interest
- tdc, time density curve
- ttp, time to peak
- web, woven endobridge
Collapse
Affiliation(s)
- Andreas Simgen
- To whom correspondence should be addressed: Andreas Simgen, M.D., Ph.D.
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Simgen A, Mayer C, Kettner M, Mühl-Benninghaus R, Reith W, Yilmaz U. Retrospective analysis of intracranial aneurysms after flow diverter treatment including color-coded imaging (syngo iFlow) as a predictor of aneurysm occlusion. Interv Neuroradiol 2022; 28:190-200. [PMID: 34107790 PMCID: PMC9131503 DOI: 10.1177/15910199211024056] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Accepted: 05/16/2021] [Indexed: 01/13/2023] Open
Abstract
PURPOSE Flow Diverters (FD) have immensely extended the treatment of cerebral aneurysms in the past years. Complete aneurysm occlusion is a process that often takes a certain amount of time and is usually difficult to predict. Our aim was to investigate different syngo iFlow parameters in order to predict aneurysm occlusion. METHODS Between 2014 and 2018 patients with unruptured cerebral aneurysms treated with a FD were reviewed. Aneurysm occlusion and complication rates have been assessed.In addition, various quantitative criteria were assessed using syngo iFlow before, after the intervention, and after short and long-term digital subtraction angiography (DSA). RESULTS A total of 66 patients hosting 66 cerebral aneurysms were included in this study. 87.9% (n = 58) aneurysms in the anterior and 12.1% (n = 8) in the posterior circulation were treated. Adequate aneurysm occlusion at long-term follow-up (19.05 ± 15.1 months) was achieved in 90.9% (n = 60). Adequately occluded aneurysm revealed a significantly greater peak intensity delay (PI-D, p = 0.008) and intensity decrease ratio (ID-R, p < 0.001) compared to insufficiently occluded aneurysms. Increased intra-aneurysmal contrast agent intensity (>100%) after FD implantation resulted in an ID-R < 1, which was associated with aneurysm growth during follow-up DSA. Retreatment with another FD due to foreshortening and/or aneurysm growth was performed in 10.6% (n = 7). Overall morbidity and mortality rates were 1.5% (n = 1) and 0%. CONCLUSION The applied syngo iFlow parameters were found to be useful in predicting adequate aneurysm occlusion and foresee aneurysm growth, which might indicate the implantation of another FD.
Collapse
Affiliation(s)
- Andreas Simgen
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | - Christine Mayer
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | - Michael Kettner
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | | | - Wolfgang Reith
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| | - Umut Yilmaz
- Departments of Neuroradiology, Saarland University
Hospital, Homburg/Saar, Germany
| |
Collapse
|
8
|
Muram S, Corcoran R, Cooke J, Forrester K, Lapins E, Morrish R, Cheema OZA, Goyal M, Eesa M, Fiorella D, Wong JH, Sadasivan C, Mitha AP. Immediate flow-diversion characteristics of a novel primarily bioresorbable flow-diverting stent. J Neurosurg 2022; 137:1794-1800. [PMID: 35364565 DOI: 10.3171/2022.1.jns212975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 01/31/2022] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Flow-diverting stents with a resorbable component have significant theoretical benefits over full metal stents, although currently there are none in clinical use. In this study, the authors sought to determine the immediate flow-diversion characteristics of a novel primarily bioresorbable flow-diverting stent. METHODS Bioresorbable stents were deployed into glass tube models to determine porosity and pore density. In vitro flow diversion behavior was evaluated using high frame rate angiography under pulsatile flow conditions in a patient-specific silicone aneurysm model treated with the resorbable stent as well as the Surpass Evolve stent. In vivo flow diversion was characterized by deployment into 20 rabbit saccular aneurysm models, and grading was based on the O'Kelly-Marotta scale and the 4F-flow diversion predictive score. RESULTS Porosities and pore densities of the bioresorbable stent were in the flow-diverting range for all target vessel diameters. Quantified results of immediate angiography after placement of the bioresorbable stent into a silicone aneurysm model demonstrated greater flow diversion compared to the Evolve stent. Bioresorbable stent placement in saccular aneurysm models resulted in an immediate O'Kelly-Marotta grade of A3 or better and a 4F-flow diversion predictive score of 4 or better in all cases. CONCLUSIONS The bioresorbable stent has immediate flow-diversion characteristics that are comparable to commercially available metal stents. Longer-term studies are underway to determine the ability of the resorbable fibers to act as a neointimal scaffold and result in long-term aneurysm occlusion.
Collapse
Affiliation(s)
- Sandeep Muram
- 1Department of Clinical Neurosciences, University of Calgary
| | | | | | | | - Elana Lapins
- 1Department of Clinical Neurosciences, University of Calgary
| | - Rosalie Morrish
- 1Department of Clinical Neurosciences, University of Calgary
| | | | - Mayank Goyal
- 1Department of Clinical Neurosciences, University of Calgary.,5Department of Radiology, University of Calgary, Alberta, Canada; and
| | - Muneer Eesa
- 1Department of Clinical Neurosciences, University of Calgary.,5Department of Radiology, University of Calgary, Alberta, Canada; and
| | - David Fiorella
- 6Department of Neurosurgery, Stony Brook University Medical Center, Stony Brook, New York
| | - John H Wong
- 1Department of Clinical Neurosciences, University of Calgary.,4Hotchkiss Brain Institute, University of Calgary.,5Department of Radiology, University of Calgary, Alberta, Canada; and
| | - Chander Sadasivan
- 6Department of Neurosurgery, Stony Brook University Medical Center, Stony Brook, New York
| | - Alim P Mitha
- 1Department of Clinical Neurosciences, University of Calgary.,3Biomedical Engineering Program, University of Calgary.,4Hotchkiss Brain Institute, University of Calgary.,5Department of Radiology, University of Calgary, Alberta, Canada; and
| |
Collapse
|
9
|
Velvaluri P, Pravdivtseva MS, Hensler J, Wodarg F, Jansen O, Quandt E, Hövener JB. A realistic way to investigate the design, and mechanical properties of flow diverter stents. Expert Rev Med Devices 2021; 18:569-579. [PMID: 33890849 DOI: 10.1080/17434440.2021.1920923] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
PURPOSE Braided flow diverters (FD) are highly sophisticated, delicate, and intricate mechanical devices used to treat intracranial aneurysms. Testing such devices in vitro, however, remains an unsolved challenge. Here, we evaluate methods to measure flow, design and mechanical properties in vitro. METHODS Flow properties, cell porosity, pore density, and cell area were evaluated under geometrically realistic conditions by placing FDs in patient-derived, 3D-printed models of human vasculature. 4D flow MRI was used to measure fluid dynamics. Laser microscopy was used to measure the design properties of the FDs. New methods were developed to investigate the bending, circumferential, and longitudinal radial force of the FDs continuously over varying diameters. RESULTS The placement and flow properties of the FD in the vasculature models were successfully measured by MRI, although artifacts occurred. Likewise, the porosity, pore density, and cell area were successfully measured inside of the models using a laser microscope. The newly developed mechanical methods allowed to measure the indicated forces - to our knowledge for the first time - continuously. CONCLUSION Modern and specifically tailored techniques, some of which were presented here for the first time, allow detailed insights into the flow, design, and mechanical properties of braided flow diverter stents.
Collapse
Affiliation(s)
| | - Mariya S Pravdivtseva
- Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| | - Johannes Hensler
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| | - Fritz Wodarg
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| | - Olav Jansen
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| | - Eckhard Quandt
- Chair of Inorganic Functional Materials, Kiel University, Kiel, Germany
| | - Jan-Bernd Hövener
- Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, Kiel, Germany
| |
Collapse
|
10
|
What is the hemodynamic effect of the Woven EndoBridge? An in vivo quantification using time-density curve analysis. Neuroradiology 2020; 62:1043-1050. [PMID: 32170371 PMCID: PMC7366603 DOI: 10.1007/s00234-020-02390-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2019] [Accepted: 02/26/2020] [Indexed: 12/20/2022]
Abstract
Purpose Using the Woven EndoBridge (WEB) for aneurysm treatment has emerged as endovascular approach aiming for flow disruption in aneurysm sac. Since quantifiable data confirming the hemodynamic effect are lacking, we investigated in vivo aneurysmal flow alterations using time-density curve (TDC) analysis. Additionally, we evaluated whether flow parameters could be identified as independent factor to predict aneurysm occlusion. Methods Forty cerebral aneurysm patients treated with WEB were enrolled. Pre- and postinterventional digital subtraction angiography series were postprocessed and TDCs generated. TDCs were quantified calculating the parameters aneurysmal inflow velocity, outflow velocity, mean flow velocity, and relative time-to-peak (rTTP) of aneurysm filling. Pre- and postinterventional values were compared and related to occlusion rate. Results WEB implanting induced highly significant rTTP prolongation by 52% (p = 0.001) and highly significant decrease of aneurysmal inflow, outflow, and mean flow velocity (p < 0.001). While outflow velocity was reduced by 49%, inflow velocity was reduced by 33% only. No statistically significant difference between the occluded and the non-occluded group was observed. No flow parameter reached significance level concerning predicting aneurysm occlusion. Conclusion Flow quantification confirms a significant flow-disrupting effect of WEB reducing more the outflow than the inflow velocity. In our small cohort, no flow parameter reached statistical significance to show predictive value regarding complete aneurysm occlusion. The hemodynamic effect of WEB is on comparable level to flow-diverting stents meaning that aneurysm closure can be delayed. In case of only slight inflow changes and high aneurysmal hemodynamic stress, some aneurysms might not be adequately protected in the short term.
Collapse
|
11
|
Hussein AE, Shownkeen M, Thomas A, Stapleton C, Brunozzi D, Nelson J, Naumgart J, Linninger A, Atwal G, Alaraj A. 2D parametric contrast time-density analysis for the prediction of complete aneurysm occlusion at six months' post-flow diversion stent. Interv Neuroradiol 2020; 26:468-475. [PMID: 32102574 DOI: 10.1177/1591019920908205] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE Indications for the treatment of cerebral aneurysms with flow diversion stents are expanding. The current aneurysm occlusion rate at six months ranges between 60 and 80%. Predictability of complete vs. partial aneurysm occlusion is poorly defined. Here, we evaluate the angiographic contrast time-density as a predictor of aneurysm occlusion rate at six months' post-flow diversion stents. METHODS Patients with unruptured cerebral aneurysms proximal to the internal carotid artery terminus treated with single flow diversion stents were included. 2D parametric parenchymal blood flow software (Siemens-Healthineers, Forchheim, Germany) was used to calculate contrast time-density within the aneurysm and in the proximal adjacent internal carotid artery. The area under the curve ratio between the two regions of interests was assessed at baseline and after flow diversion stents deployment. The area under the curve ratio between completely vs. partially occluded aneurysms at six months' follow-up was compared. RESULTS Thirty patients with 31 aneurysms were included. Mean aneurysm diameter was 8 mm (range 2-28 mm). Complete occlusion was obtained in 19 aneurysms. Younger patients (P = 0.006) and smaller aneurysms (P = 0.046) presented higher chance of complete obliteration. Incomplete occlusion of the aneurysm was more likely if the area under the curve contrast time-density ratio showed absolute (P = 0.001) and relative percentage (P = 0.001) decrease after flow diversion stents deployment. Area under ROC curve was 0.85. CONCLUSION Negative change in the area under the curve ratio indicates less contrast stagnation in the aneurysm and lower chance of occlusion. These data provide a real-time analysis after aneurysm treatment. If validated in larger datasets, this can prompt input to the surgeon to place a second flow diversion stents.
Collapse
Affiliation(s)
- Ahmed E Hussein
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Meghana Shownkeen
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Andre Thomas
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA
| | | | - Denise Brunozzi
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA
| | | | | | - Andreas Linninger
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA.,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, USA
| | - Gursant Atwal
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA
| | - Ali Alaraj
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, USA.,Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, USA
| |
Collapse
|
12
|
Sadasivan C, Fiorella D. Preliminary in vitro angiographic comparison of the flow diversion behavior of Evolve and Pipeline devices. J Neurointerv Surg 2019; 12:616-620. [DOI: 10.1136/neurintsurg-2019-015455] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 10/29/2019] [Accepted: 10/31/2019] [Indexed: 11/04/2022]
Abstract
Background and purposeFlow diverters are increasingly used to treat a broad category of cerebral aneurysms. We conducted an in vitro study to angiographically compare the flow diversion effect of Surpass Evolve from Stryker Neurovascular with the Pipeline Shield Embolization Device from Medtronic Neurovascular.MethodsThree copies each of three carotid aneurysm geometries were manufactured from silicone. Evolve and Pipeline flow diverters were deployed in one copy of each geometry; the third copy was used as Control. High-speed angiography was acquired under pulsatile flow in each replica, contrast concentration-time curves within the aneurysms were recorded, and the curves were quantified with six parameters. The parameters were statistically evaluated to compare the flow diversion effect of both devices.ResultsThe Evolve showed greater flow diversion trends in almost all intra-geometry comparisons than the Pipeline. When aggregated over the three geometries, the Evolve was statistically significantly better than the Pipeline in four of the six parameters, and about the same or better (not statistically significant) than the Pipeline in the other two parameters.ConclusionsThe Evolve device demonstrated greater in vitro flow diversion effects than Pipeline. Comparative efficacy of the devices will need to be adjudicated based on clinical outcomes.
Collapse
|