1
|
Leighton MP, Kreplak L, Rutenberg AD. Torsion and bistability of double-twist elastomers. SOFT MATTER 2023; 19:6376-6386. [PMID: 37577969 DOI: 10.1039/d3sm00554b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
We investigate the elastic properties of anisotropic elastomers with a double-twist director field, which is a model for collagen fibrils or blue phases. We observe a significant Poynting-like effect, coupling torsion (fibril twist) and extension. For freely-rotating boundary conditions, we identify a structural bistability at very small extensional strains which undergoes a saddle-node bifurcation at a critical strain - at approximately 1% strain for a parameterization appropriate for collagen fibrils. With clamped boundary conditions appropriate for many experimental setups, the bifurcation is not present. We expect significant helical shape effects when fixed torsion does not equal the equilibrium torsion of freely-rotating boundary conditions, due to residual torques.
Collapse
Affiliation(s)
- Matthew P Leighton
- Department of Physics, Simon Fraser University, Burnaby, British Columbia, V5A 1S6, Canada
| | - Laurent Kreplak
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
| | - Andrew D Rutenberg
- Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, B3H 4R2, Canada.
| |
Collapse
|
2
|
Flores DV, Murray T, Jacobson JA. Diagnostic and Interventional US of the Wrist and Hand: Quadrant-based Approach. Radiographics 2023; 43:e230046. [PMID: 37498783 DOI: 10.1148/rg.230046] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
Diagnostic and interventional US of the wrist and hand can be challenging due to the small size and superficial location of structures and various disorders that need to be considered. A quadrant-based approach (volar, ulnar, dorsal, and radial) provides a rational method for performing a focused examination and joint positioning during both diagnostic imaging and intervention. Volar wrist disorders primarily involve the median nerve and the digital flexor system comprised of the flexor tendons and pulleys. The ulnar nerve and extensor carpi ulnaris tendon are chiefly responsible for ulnar-sided wrist pain. The differential diagnosis for dorsal-sided symptoms typically involves the extensor tendon compartments and includes distal intersection syndrome, extensor pollicis longus tear, and digital extensor apparatus injury. The soft-tissue ganglion is the most common abnormality in the dorsal wrist, typically associated with wrist ligaments or joint capsule. Radial-sided pain may be secondary to de Quervain tenosynovitis and must be differentiated from the more proximal intersection syndrome. US is an important tool for assessing the ulnar collateral ligament of the first metacarpophalangeal joint of the thumb and differentiating between displaced and nondisplaced tears, thereby influencing management. Despite the complexity of the anatomy and potential pathologic features within the wrist, a focused quadrant-based examination can permit the sonologist to focus on the structures of relevance. In conjunction with a systematic approach, this can aid in precise and efficient diagnostic scanning and intervention of the wrist and hand. ©RSNA, 2023 Supplemental material is available for this article. Quiz questions for this article are available through the Online Learning Center.
Collapse
Affiliation(s)
- Dyan V Flores
- From the Department of Radiology, Radiation Oncology and Medical Physics, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada K1H 8L6 (D.V.F.); Department of Medical Imaging, The Ottawa Hospital, Ottawa, Ontario, Canada (D.V.F.); Ottawa Hospital Research Institute, Ottawa, Ontario, Canada (D.V.F.); Department of Radiology, St Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada (T.M.); Lenox Hill Radiology and Medical Imaging, New York, NY (J.A.J.); and Department of Radiology, University of California-San Diego, San Diego, Calif (J.A.J.)
| | - Timothy Murray
- From the Department of Radiology, Radiation Oncology and Medical Physics, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada K1H 8L6 (D.V.F.); Department of Medical Imaging, The Ottawa Hospital, Ottawa, Ontario, Canada (D.V.F.); Ottawa Hospital Research Institute, Ottawa, Ontario, Canada (D.V.F.); Department of Radiology, St Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada (T.M.); Lenox Hill Radiology and Medical Imaging, New York, NY (J.A.J.); and Department of Radiology, University of California-San Diego, San Diego, Calif (J.A.J.)
| | - Jon A Jacobson
- From the Department of Radiology, Radiation Oncology and Medical Physics, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada K1H 8L6 (D.V.F.); Department of Medical Imaging, The Ottawa Hospital, Ottawa, Ontario, Canada (D.V.F.); Ottawa Hospital Research Institute, Ottawa, Ontario, Canada (D.V.F.); Department of Radiology, St Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada (T.M.); Lenox Hill Radiology and Medical Imaging, New York, NY (J.A.J.); and Department of Radiology, University of California-San Diego, San Diego, Calif (J.A.J.)
| |
Collapse
|
3
|
Maes A, Pestiaux C, Marino A, Balcaen T, Leyssens L, Vangrunderbeeck S, Pyka G, De Borggraeve WM, Bertrand L, Beauloye C, Horman S, Wevers M, Kerckhofs G. Cryogenic contrast-enhanced microCT enables nondestructive 3D quantitative histopathology of soft biological tissues. Nat Commun 2022; 13:6207. [PMID: 36266273 PMCID: PMC9584947 DOI: 10.1038/s41467-022-34048-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 10/12/2022] [Indexed: 12/24/2022] Open
Abstract
Biological tissues comprise a spatially complex structure, composition and organization at the microscale, named the microstructure. Given the close structure-function relationships in tissues, structural characterization is essential to fully understand the functioning of healthy and pathological tissues, as well as the impact of possible treatments. Here, we present a nondestructive imaging approach to perform quantitative 3D histo(patho)logy of biological tissues, termed Cryogenic Contrast-Enhanced MicroCT (cryo-CECT). By combining sample staining, using an X-ray contrast-enhancing staining agent, with freezing the sample at the optimal freezing rate, cryo-CECT enables 3D visualization and structural analysis of individual tissue constituents, such as muscle and collagen fibers. We applied cryo-CECT on murine hearts subjected to pressure overload following transverse aortic constriction surgery. Cryo-CECT allowed to analyze, in an unprecedented manner, the orientation and diameter of the individual muscle fibers in the entire heart, as well as the 3D localization of fibrotic regions within the myocardial layers. We foresee further applications of cryo-CECT in the optimization of tissue/food preservation and donor banking, showing that cryo-CECT also has clinical and industrial potential.
Collapse
Affiliation(s)
- Arne Maes
- Department of Materials Engineering, KU Leuven, Heverlee, Belgium
- Biomechanics lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
| | - Camille Pestiaux
- Biomechanics lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
| | - Alice Marino
- Pole of Cardiovascular Research, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
| | - Tim Balcaen
- Biomechanics lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
- Molecular Design and Synthesis, Department of Chemistry, KU Leuven, Leuven, Belgium
| | - Lisa Leyssens
- Biomechanics lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
| | - Sarah Vangrunderbeeck
- Biomechanics lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
- Molecular Design and Synthesis, Department of Chemistry, KU Leuven, Leuven, Belgium
| | - Grzegorz Pyka
- Biomechanics lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium
- Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
| | - Wim M De Borggraeve
- Molecular Design and Synthesis, Department of Chemistry, KU Leuven, Leuven, Belgium
| | - Luc Bertrand
- Pole of Cardiovascular Research, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
| | | | - Sandrine Horman
- Pole of Cardiovascular Research, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium
| | - Martine Wevers
- Department of Materials Engineering, KU Leuven, Heverlee, Belgium
| | - Greet Kerckhofs
- Department of Materials Engineering, KU Leuven, Heverlee, Belgium.
- Biomechanics lab, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium.
- Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Brussels, Belgium.
- Prometheus, Division for Skeletal Tissue Engineering, KU Leuven, Leuven, Belgium.
| |
Collapse
|
4
|
Morin C, Hellmich C, Nejim Z, Avril S. Fiber Rearrangement and Matrix Compression in Soft Tissues: Multiscale Hypoelasticity and Application to Tendon. Front Bioeng Biotechnol 2021; 9:725047. [PMID: 34712652 PMCID: PMC8546211 DOI: 10.3389/fbioe.2021.725047] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Accepted: 09/06/2021] [Indexed: 11/13/2022] Open
Abstract
It is widely accepted that the nonlinear macroscopic mechanical behavior of soft tissue is governed by fiber straightening and re-orientation. Here, we provide a quantitative assessment of this phenomenon, by means of a continuum micromechanics approach. Given the negligibly small bending stiffness of crimped fibers, the latter are represented through a number of hypoelastic straight fiber phases with different orientations, being embedded into a hypoelastic matrix phase. The corresponding representative volume element (RVE) hosting these phases is subjected to “macroscopic” strain rates, which are downscaled to fiber and matrix strain rates on the one hand, and to fiber spins on the other hand. This gives quantitative access to the fiber decrimping (or straightening) phenomenon under non-affine conditions, i.e. in the case where the fiber orientations cannot be simply linked to the macroscopic strain state. In the case of tendinous tissue, such an RVE relates to the fascicle material with 50 μm characteristic length, made up of crimped collagen bundles and a gel-type matrix in-between. The fascicles themselves act as parallel fibers in a similar matrix at the scale of a tissue-related RVE with 500 μm characteristic length. As evidenced by a sensitivity analysis and confirmed by various mechanical tests, it is the initial crimping angle which drives both the degree of straightening and the shape of the macroscopic stress-strain curve, while the final linear portion of this curve depends almost exclusively on the collagen bundle elasticity. Our model also reveals the mechanical cooperation of the tissue’s key microstructural components: while the fibers carry tensile forces, the matrices undergo hydrostatic pressure.
Collapse
Affiliation(s)
- Claire Morin
- Mines Saint-Etienne, Univ. Lyon, Univ. Jean Monnet, INSERM, U1059 Sainbiose, Centre CIS, Saint-Etienne, France
| | - Christian Hellmich
- Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Vienna, Austria
| | - Zeineb Nejim
- Mines Saint-Etienne, Univ. Lyon, Univ. Jean Monnet, INSERM, U1059 Sainbiose, Centre CIS, Saint-Etienne, France
| | - Stéphane Avril
- Mines Saint-Etienne, Univ. Lyon, Univ. Jean Monnet, INSERM, U1059 Sainbiose, Centre CIS, Saint-Etienne, France.,Institute for Mechanics of Materials and Structures, TU Wien - Vienna University of Technology, Vienna, Austria
| |
Collapse
|
5
|
Liu J, Xu MY, Wu J, Zhang H, Yang L, Lun DX, Hu YC, Liu B. Picrosirius-Polarization Method for Collagen Fiber Detection in Tendons: A Mini-Review. Orthop Surg 2021; 13:701-707. [PMID: 33689233 PMCID: PMC8126917 DOI: 10.1111/os.12627] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Revised: 01/14/2020] [Accepted: 01/14/2020] [Indexed: 12/31/2022] Open
Abstract
Although the structure and composition of collagen have been studied by polarized light microscopy since the early 19th century, many studies and reviews have paid little or no attention to the morphological problems of histopathological diagnosis. The morphology of collagen fibers is critical in guiding mechanical and biological properties in both normal and pathological tendons. Highlighting the organization and spatial distribution of tendon‐containing collagen fibers can be very useful for visualizing a tendon's ultrastructure, biochemical and indirect mechanical properties, which benefits other researchers and clinicians. Picrosirius red (PSR) staining, relying on the birefringence of collagen fibers, is one of the best understood histochemical methods that can highly and specifically underline fibers better than other common staining techniques when combined with polarized light microscopy (PLM). Polarized light microscopy provides complementary information about collagen fibers, such as orientation, type and spatial distribution, which is important for a comprehensive assessment of collagen alteration in a tendon. Here, this brief review serves as a simplistic and important primer to research developments in which differential staining of collagen types by the Picrosirius‐polarization method is increasing in diverse studies of the medical field, mainly in the assessment of the morphology, spatial distribution, and content of collagen in tendons.
Collapse
Affiliation(s)
- Jie Liu
- Tianjin Medical University, Tianjin, China
| | | | - Jing Wu
- Center for Medical Device Evaluation NMPA, Beijing, China
| | | | - Li Yang
- Tianjin Hospital, Tianjin, China
| | | | | | - Bin Liu
- Center for Medical Device Evaluation NMPA, Beijing, China
| |
Collapse
|
6
|
Tracking tendon fibers to their insertion - a 3D analysis of the Achilles tendon enthesis in mice. Acta Biomater 2021; 120:146-155. [PMID: 32428686 DOI: 10.1016/j.actbio.2020.05.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 04/16/2020] [Accepted: 05/01/2020] [Indexed: 11/23/2022]
Abstract
Tendon insertions to bone are heavily loaded transitions between soft and hard tissues. The fiber courses in the tendon have profound effects on the distribution of stress along and across the insertion. We tracked fibers of the Achilles tendon in mice in micro-computed tomographies and extracted virtual transversal sections. The fiber tracks and shapes were analyzed from a position in the free tendon to the insertion. Mechanically relevant parameters were extracted. The fiber number was found to stay about constant along the tendon. But the fiber cross-sectional areas decrease towards the insertion. The fibers mainly interact due to tendon twist, while branching only creates small branching clusters with low levels of divergence along the tendon. The highest fiber curvatures were found within the unmineralized entheseal fibrocartilage. The fibers inserting at a protrusion of the insertion area form a distinct portion within the tendon. Tendon twist is expected to contribute to a homogeneous distribution of stress among the fibers. According to the low cross-sectional areas and the high fiber curvatures, tensile and compressive stress are expected to peak at the insertion. These findings raise the question whether the insertion is reinforced in terms of fiber strength or by other load-bearing components besides the fibers. STATEMENT OF SIGNIFICANCE: The presented study is the first analysis of the 3D fiber tracks in macroscopic tendon samples as determined by a combination of cell-maceration, phase-contrast µCT and template-based tracking. The structural findings change the understanding of the tendon-bone insertion and its biomechanics: (1) The insertion is not reinforced in terms of fiber numbers or sizes. Its robustness remains unexplained. (2) The orientation of fibers in the tendon center is higher than in the margins. This arrangement could inspire material development. (3) Fibers inserting at a protrusion of the insertion area stem from a distinct portion within the tendon. The results show that fibrous structure analysis can link macro- to micromechanics and that it is ready for the application to complete muscle-tendon units.
Collapse
|
7
|
Thompson N, Ravagli E, Mastitskaya S, Iacoviello F, Aristovich K, Perkins J, Shearing PR, Holder D. MicroCT optimisation for imaging fascicular anatomy in peripheral nerves. J Neurosci Methods 2020; 338:108652. [PMID: 32179090 PMCID: PMC7181190 DOI: 10.1016/j.jneumeth.2020.108652] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2019] [Revised: 02/24/2020] [Accepted: 02/25/2020] [Indexed: 01/25/2023]
Abstract
BACKGROUND Due to the lack of understanding of the fascicular organisation, vagus nerve stimulation (VNS) leads to unwanted off-target effects. Micro-computed tomography (microCT) can be used to trace fascicles from periphery and image fascicular anatomy. NEW METHOD In this study, we present a simple and reproducible method for imaging fascicles in peripheral nerves with iodine staining and microCT for the determination of fascicular anatomy and organisation. RESULTS At the determined optimal pre-processing steps and scanning parameters, the microCT protocol allowed for segmentation and tracking of fascicles within the nerves. This was achieved after 24 hours and 120 hours of staining with Lugol's solution (1% total iodine) for rat sciatic and pig vagus nerves, respectively, and the following scanning parameters: 4 μm voxel size, 35 kVp energy, 114 μA current, 4 W power, 0.25 fps in 4 s exposure time, 3176 projections and a molybdenum target. COMPARISON WITH EXISTING METHOD(S) This optimised method for imaging fascicles provides high-resolution, three-dimensional images and full imaging penetration depth not obtainable with methods typically used such as histology, magnetic resonance imaging and optical coherence tomography whilst obviating time-consuming pre-processing methods, the amount of memory required, destruction of the samples and the cost associated with current microCT methods. CONCLUSION The optimised microCT protocol facilitates segmentation and tracking of the fascicles within the nerve. The resulting segmentation map of the functional anatomical organisation of the vagus nerve will enable selective VNS ultimately allowing for the avoidance of the off-target effects and improving its therapeutic efficacy.
Collapse
Affiliation(s)
- Nicole Thompson
- EIT and Neurophysiology Lab, Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, United Kingdom.
| | - Enrico Ravagli
- EIT and Neurophysiology Lab, Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, United Kingdom
| | - Svetlana Mastitskaya
- EIT and Neurophysiology Lab, Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, United Kingdom
| | - Francesco Iacoviello
- Electrochemical Innovation Lab, Chemical Engineering, University College London, Gower Street, London, WC1E 6BT, United Kingdom
| | - Kirill Aristovich
- EIT and Neurophysiology Lab, Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, United Kingdom
| | - Justin Perkins
- Clinical Science and Services, The Royal Veterinary College, Hawkshead Lane, Hatfield, AL9 7TA, United Kingdom
| | - Paul R Shearing
- Electrochemical Innovation Lab, Chemical Engineering, University College London, Gower Street, London, WC1E 6BT, United Kingdom
| | - David Holder
- EIT and Neurophysiology Lab, Medical Physics and Biomedical Engineering, University College London, Gower Street, London, WC1E 6BT, United Kingdom
| |
Collapse
|
8
|
Safa BN, Peloquin JM, Natriello JR, Caplan JL, Elliott DM. Helical fibrillar microstructure of tendon using serial block-face scanning electron microscopy and a mechanical model for interfibrillar load transfer. J R Soc Interface 2019; 16:20190547. [PMID: 31744419 DOI: 10.1098/rsif.2019.0547] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Tendon's hierarchical structure allows for load transfer between its fibrillar elements at multiple length scales. Tendon microstructure is particularly important, because it includes the cells and their surrounding collagen fibrils, where mechanical interactions can have potentially important physiological and pathological contributions. However, the three-dimensional (3D) microstructure and the mechanisms of load transfer in that length scale are not known. It has been postulated that interfibrillar matrix shear or direct load transfer via the fusion/branching of small fibrils are responsible for load transfer, but the significance of these mechanisms is still unclear. Alternatively, the helical fibrils that occur at the microstructural scale in tendon may also mediate load transfer; however, these structures are not well studied due to the lack of a three-dimensional visualization of tendon microstructure. In this study, we used serial block-face scanning electron microscopy to investigate the 3D microstructure of fibrils in rat tail tendon. We found that tendon fibrils have a complex architecture with many helically wrapped fibrils. We studied the mechanical implications of these helical structures using finite-element modelling and found that frictional contact between helical fibrils can induce load transfer even in the absence of matrix bonding or fibril fusion/branching. This study is significant in that it provides a three-dimensional view of the tendon microstructure and suggests friction between helically wrapped fibrils as a mechanism for load transfer, which is an important aspect of tendon biomechanics.
Collapse
Affiliation(s)
- Babak N Safa
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA.,Department of Mechanical Engineering, University of Delaware, Newark, DE, USA
| | - John M Peloquin
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Jessica R Natriello
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | - Jeffrey L Caplan
- Department of Plant and Soil Sciences, University of Delaware, Newark, DE, USA.,Delaware Biotechnology Institute, University of Delaware, Newark, DE, USA
| | - Dawn M Elliott
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| |
Collapse
|
9
|
Sonographic imaging of hand and wrist injuries: applications in the ER setting. Emerg Radiol 2018; 26:227-240. [DOI: 10.1007/s10140-018-1649-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 09/26/2018] [Indexed: 01/14/2023]
|
10
|
Sartori J, Köhring S, Witte H, Fischer MS, Löffler M. Three-dimensional imaging of the fibrous microstructure of Achilles tendon entheses in Mus musculus. J Anat 2018; 233:370-380. [PMID: 29920671 PMCID: PMC6081500 DOI: 10.1111/joa.12837] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/09/2018] [Indexed: 12/20/2022] Open
Abstract
The whole-organ, three-dimensional microstructure of murine Achilles tendon entheses was visualized with micro-computed tomography (microCT). Contrast-enhancement was achieved either by staining with phosphotungstic acid (PTA) or by a combination of cell-maceration, demineralization and critical-point drying with low tube voltages and propagation-based phase-contrast (fibrous structure scan). By PTA-staining, X-ray absorption of the enthesial soft tissues became sufficiently high to segment the tendon and measure cross-sectional areas along its course. With the fibrous structure scans, three-dimensional visualizations of the collagen fiber networks of complete entheses were obtained. The characteristic tissues of entheses were identified in the volume data. The tendon proper was marked as a segment manually. The fibers within the tendon were marked by thresholding. Tendon and fiber cross-sectional areas were measured. The measurements were compared between individuals and protocols for contrast-enhancement, using a spatial reference system within the three-dimensional enthesis. The usefulness of the method for investigations of the fibrous structure of collagenous tissues is demonstrated.
Collapse
Affiliation(s)
- Julian Sartori
- Institut für Zoologie und EvolutionsforschungFriedrich‐Schiller‐Universität JenaJenaGermany
| | - Sebastian Köhring
- Fachgebiet BiomechatronikFakultät für Maschinenbau / IMN MacroNano®Technische Universität IlmenauIlmenauGermany
| | - Hartmut Witte
- Fachgebiet BiomechatronikFakultät für Maschinenbau / IMN MacroNano®Technische Universität IlmenauIlmenauGermany
| | - Martin S. Fischer
- Institut für Zoologie und EvolutionsforschungFriedrich‐Schiller‐Universität JenaJenaGermany
| | - Markus Löffler
- Dresden Center for Nanoanalysis (DCN)Center for Advancing Electronics Dresden (cfaed)Technische Universität DresdenDresdenGermany
| |
Collapse
|
11
|
Disney CM, Lee PD, Hoyland JA, Sherratt MJ, Bay BK. A review of techniques for visualising soft tissue microstructure deformation and quantifying strain Ex Vivo. J Microsc 2018; 272:165-179. [PMID: 29655273 DOI: 10.1111/jmi.12701] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2018] [Revised: 03/08/2018] [Accepted: 03/16/2018] [Indexed: 12/16/2022]
Abstract
Many biological tissues have a complex hierarchical structure allowing them to function under demanding physiological loading conditions. Structural changes caused by ageing or disease can lead to loss of mechanical function. Therefore, it is necessary to characterise tissue structure to understand normal tissue function and the progression of disease. Ideally intact native tissues should be imaged in 3D and under physiological loading conditions. The current published in situ imaging methodologies demonstrate a compromise between imaging limitations and maintaining the samples native mechanical function. This review gives an overview of in situ imaging techniques used to visualise microstructural deformation of soft tissue, including three case studies of different tissues (tendon, intervertebral disc and artery). Some of the imaging techniques restricted analysis to observational mechanics or discrete strain measurement from invasive markers. Full-field local surface strain measurement has been achieved using digital image correlation. Volumetric strain fields have successfully been quantified from in situ X-ray microtomography (micro-CT) studies of bone using digital volume correlation but not in soft tissue due to low X-ray transmission contrast. With the latest developments in micro-CT showing in-line phase contrast capability to resolve native soft tissue microstructure, there is potential for future soft tissue mechanics research where 3D local strain can be quantified. These methods will provide information on the local 3D micromechanical environment experienced by cells in healthy, aged and diseased tissues. It is hoped that future applications of in situ imaging techniques will impact positively on the design and testing of potential tissue replacements or regenerative therapies. LAY DESCRIPTION: The soft tissues in our bodies, such as tendons, intervertebral discs and arteries, have evolved to have complicated structures which deform and bear load during normal function. Small changes in these structures can occur with age and disease which then leads to loss of function. Therefore, it is important to image tissue microstructure in 3D and under functional conditions. This paper gives an overview of imaging techniques used to record the deformation of soft tissue microstructures. Commonly there are compromises between obtaining the best imaging result and retaining the samples native structure and function. For example, invasive markers and dissecting samples damages the tissues natural structure, and staining or clearing (making the tissue more transparent) can distort tissue structure. Structural deformation has been quantified from 2D imaging techniques (digital image correlation) to create surface strain maps which help identify local tissue mechanics. When extended to 3D (digital volume correlation), deformation measurement has been limited to bone samples using X-ray micro-CT. Recently it has been possible to image the 3D structure of soft tissue using X-ray micro-CT meaning that there is potential for internal soft tissue mechanics to be mapped in 3D. Future application of micro-CT and digital volume correlation will be important for soft tissue mechanics studies particularly to understand normal function, progression of disease and in the design of tissue replacements.
Collapse
Affiliation(s)
- C M Disney
- Centre for Doctoral Training in Regenerative Medicine, University of Manchester, Manchester, U.K.,Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, U.K
| | - P D Lee
- School of Materials, University of Manchester, Manchester, U.K
| | - J A Hoyland
- Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, U.K.,NIHR Manchester Biomedical Research Centre, Manchester Academic Health Science Centre, Central Manchester University Hospitals NHS Foundation Trust, Manchester, U.K
| | - M J Sherratt
- Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, U.K
| | - B K Bay
- School of Mechanical, Industrial and Manufacturing Engineering, Oregon State University, Corvallis, Oregon, U.S.A
| |
Collapse
|
12
|
Disney CM, Madi K, Bodey AJ, Lee PD, Hoyland JA, Sherratt MJ. Visualising the 3D microstructure of stained and native intervertebral discs using X-ray microtomography. Sci Rep 2017; 7:16279. [PMID: 29176563 PMCID: PMC5701246 DOI: 10.1038/s41598-017-16354-w] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2017] [Accepted: 11/10/2017] [Indexed: 01/31/2023] Open
Abstract
Intervertebral disc degeneration (IVDD) is linked to low back pain. Microstructural changes during degeneration have previously been imaged using 2D sectioning techniques and 3D methods which are limited to small specimens and prone to inducing artefacts from sample preparation. This study explores micro computed X-ray tomography (microCT) methods with the aim of resolving IVD 3D microstructure whilst minimising sample preparation artefacts. Low X-ray absorption contrast in non-mineralised tissue can be enhanced using staining and phase contrast techniques. A step-wise approach, including comparing three stains, was used to develop microCT for bovine tail IVD using laboratory and synchrotron sources. Staining successfully contrasted collagenous structures; however not all regions were stained and the procedure induced macroscopic structural changes. Phase contrast microCT of chemically fixed yet unstained samples resolved the nucleus pulposus, annulus fibrosus and constituent lamellae, and finer structures including collagen bundles and cross-bridges. Using the same imaging methods native tissue scans were of slightly lower contrast but free from sample processing artefacts. In the future these methods may be used to characterise structural remodelling in soft (non-calcified) tissues and to conduct in situ studies of native loaded tissues and constructs to characterise their 3D mechanical properties.
Collapse
Affiliation(s)
- C M Disney
- Centre for Doctoral Training in Regenerative Medicine, University of Manchester, Manchester, UK.,Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, UK
| | - K Madi
- School of Materials, University of Manchester, Manchester, UK
| | - A J Bodey
- Diamond Light Source, Harwell Science and Innovation Campus, Oxfordshire, UK
| | - P D Lee
- School of Materials, University of Manchester, Manchester, UK
| | - J A Hoyland
- Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, UK.,NIHR Manchester Biomedical Research Centre, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
| | - M J Sherratt
- Division of Cell Matrix Biology and Regenerative Medicine, University of Manchester, Manchester, UK.
| |
Collapse
|
13
|
Buchanan KA, Lakes RS, Vanderby R. Chiral behavior in rat tail tendon fascicles. J Biomech 2017; 64:206-211. [DOI: 10.1016/j.jbiomech.2017.09.034] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2017] [Revised: 09/16/2017] [Accepted: 09/25/2017] [Indexed: 11/28/2022]
|
14
|
Abstract
OBJECTIVE This article reviews the normal anatomy of the extensor tendons of the wrist as well as the clinical presentation and MRI appearances of common tendon abnormalities, such as tears, tenosynovitis, intersection syndromes, and associated or predisposing osseous findings. Treatment options are also discussed. CONCLUSION We review the anatomy and normal MRI appearance of the clinically important dorsal extensor tendons of the wrist, in addition to the spectrum of abnormalities associated with these tendons.
Collapse
|
15
|
Fang F, Lake SP. Experimental evaluation of multiscale tendon mechanics. J Orthop Res 2017; 35:1353-1365. [PMID: 27878999 DOI: 10.1002/jor.23488] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Accepted: 11/16/2016] [Indexed: 02/04/2023]
Abstract
Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| | - Spencer P Lake
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130.,Department of Orthopaedic Surgery, Washington University in St. Louis, 1 Brookings Drive, Campus Box 1185, St. Louis, Missouri, 63130
| |
Collapse
|
16
|
Shearer T, Bradley RS, Hidalgo-Bastida LA, Sherratt MJ, Cartmell SH. Three-dimensional visualisation of soft biological structures by X-ray computed micro-tomography. J Cell Sci 2016; 129:2483-92. [PMID: 27278017 DOI: 10.1242/jcs.179077] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Whereas the two-dimensional (2D) visualisation of biological samples is routine, three-dimensional (3D) imaging remains a time-consuming and relatively specialised pursuit. Current commonly adopted techniques for characterising the 3D structure of non-calcified tissues and biomaterials include optical and electron microscopy of serial sections and sectioned block faces, and the visualisation of intact samples by confocal microscopy or electron tomography. As an alternative to these approaches, X-ray computed micro-tomography (microCT) can both rapidly image the internal 3D structure of macroscopic volumes at sub-micron resolutions and visualise dynamic changes in living tissues at a microsecond scale. In this Commentary, we discuss the history and current capabilities of microCT. To that end, we present four case studies to illustrate the ability of microCT to visualise and quantify: (1) pressure-induced changes in the internal structure of unstained rat arteries, (2) the differential morphology of stained collagen fascicles in tendon and ligament, (3) the development of Vanessa cardui chrysalises, and (4) the distribution of cells within a tissue-engineering construct. Future developments in detector design and the use of synchrotron X-ray sources might enable real-time 3D imaging of dynamically remodelling biological samples.
Collapse
Affiliation(s)
- Tom Shearer
- School of Materials, University of Manchester, Manchester M13 9PL, UK School of Mathematics, University of Manchester, Manchester M13 9PL, UK
| | - Robert S Bradley
- Henry Moseley X-ray Imaging Facility, School of Materials, University of Manchester, Manchester M13 9PL, UK
| | | | - Michael J Sherratt
- Institute of Inflammation and Repair, University of Manchester, Manchester M13 9PL, UK
| | - Sarah H Cartmell
- School of Materials, University of Manchester, Manchester M13 9PL, UK
| |
Collapse
|
17
|
Balint R, Lowe T, Shearer T. Optimal Contrast Agent Staining of Ligaments and Tendons for X-Ray Computed Tomography. PLoS One 2016; 11:e0153552. [PMID: 27078030 PMCID: PMC4831740 DOI: 10.1371/journal.pone.0153552] [Citation(s) in RCA: 44] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2015] [Accepted: 03/31/2016] [Indexed: 01/05/2023] Open
Abstract
X-ray computed tomography has become an important tool for studying the microstructures of biological soft tissues, such as ligaments and tendons. Due to the low X-ray attenuation of such tissues, chemical contrast agents are often necessary to enhance contrast during scanning. In this article, the effects of using three different contrast agents—iodine potassium iodide solution, phosphotungstic acid and phosphomolybdic acid—are evaluated and compared. Porcine anterior cruciate ligaments, patellar tendons, medial collateral ligaments and lateral collateral ligaments were used as the basis of the study. Three samples of each of the four ligament/tendon types were each assigned a different contrast agent (giving a total of twelve samples), and the progression of that agent through the tissue was monitored by performing a scan every day for a total period of five days (giving a total of sixty scans). Since the samples were unstained on day one, they had been stained for a total of four days by the time of the final scans. The relative contrast enhancement and tissue deformation were measured. It was observed that the iodine potassium iodide solution penetrated the samples fastest and caused the least sample shrinkage on average (although significant deformation was observed by the time of the final scans), whereas the phosphomolybdic acid caused the greatest sample shrinkage. Equations describing the observed behaviour of the contrast agents, which can be used to predict optimal staining times for ligament and tendon X-ray computed tomography, are presented.
Collapse
Affiliation(s)
- Richard Balint
- School of Materials, University of Manchester, Manchester, United Kingdom
| | - Tristan Lowe
- Henry Moseley X-ray Imaging Facility, School of Materials, University of Manchester, Manchester, United Kingdom
| | - Tom Shearer
- School of Materials, University of Manchester, Manchester, United Kingdom
- School of Mathematics, University of Manchester, Manchester, United Kingdom
- * E-mail:
| |
Collapse
|
18
|
Abstract
Tendon exhibits anisotropic, inhomogeneous and viscoelastic mechanical properties that are determined by its complicated hierarchical structure and varying amounts/organization of different tissue constituents. Although extensive research has been conducted to use modelling approaches to interpret tendon structure-function relationships in combination with experimental data, many issues remain unclear (i.e. the role of minor components such as decorin, aggrecan and elastin), and the integration of mechanical analysis across different length scales has not been well applied to explore stress or strain transfer from macro- to microscale. This review outlines mathematical and computational models that have been used to understand tendon mechanics at different scales of the hierarchical organization. Model representations at the molecular, fibril and tissue levels are discussed, including formulations that follow phenomenological and microstructural approaches (which include evaluations of crimp, helical structure and the interaction between collagen fibrils and proteoglycans). Multiscale modelling approaches incorporating tendon features are suggested to be an advantageous methodology to understand further the physiological mechanical response of tendon and corresponding adaptation of properties owing to unique in vivo loading environments.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering and Materials Science , Washington University in St Louis , St Louis, MO 63130 , USA
| | - Spencer P Lake
- Department of Mechanical Engineering and Materials Science, Washington University in St Louis, St Louis, MO 63130, USA; Department of Biomedical Engineering, Washington University in St Louis, St Louis, MO 63130, USA; Department of Orthopaedic Surgery, Washington University in St Louis, St Louis, MO 63130, USA
| |
Collapse
|
19
|
Ali S, Cunningham R, Amin M, Popoff SN, Mohamed F, Barbe MF. The extensor carpi ulnaris pseudolesion: evaluation with microCT, histology, and MRI. Skeletal Radiol 2015; 44:1735-43. [PMID: 26245773 PMCID: PMC4609633 DOI: 10.1007/s00256-015-2224-3] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 07/08/2015] [Accepted: 07/22/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To determine if magic angle plays a role in apparent central increased signal intensity of the distal extensor carpi ulnaris tendon (ECU) on MRI, to see if histologic findings of tendon degeneration are associated with increased T1 or T2 tendon signal on MR imaging, and to determine the prevalence of the ECU "pseudolesion". MATERIALS AND METHODS A standard 3 Tesla protocol was utilized to scan ten cadaveric wrists. A 40 mm length of 10 ECU and four extensor carpi radialis brevis (ECRB) tendons were immersion fixed before microCT scanning. Staining with Alcian blue, Masson's trichrome and Safranin O was performed before light microscopy. Fifty clinical wrist MRIs were also reviewed for the presence of increased T1 and/or T2 signal. RESULTS Central increased T1 and/or T2 signal was observed in 9 of 10 cadaveric ECU tendons, but not in ECRB tendons. MicroCT and histology showed inter-tendinous matrix between the two distal heads of the ECU. Increased mucoid degeneration correlated with increased MRI signal intensity. The tendon fibers were at a maximum of 8.39° to the longitudinal axis on microCT. Clinical MRIs showed increased T1 signal in 6%, increased T2 signal in 8%, increased T1 and T2 signal in 80%, and 6% showing no increased signal. CONCLUSION Central increased T1 and/or T2 signal in the ECU tendon indicates the presence of normal inter-tendinous ground substance, with increased proteoglycan content (mucoid degeneration) responsible for increased signal intensity. None of the fibers were shown on microCT to approach the magic angle.
Collapse
Affiliation(s)
- Sayed Ali
- Department of Radiology, Temple University Hospital, 3401 North Broad Street, Philadelphia, PA, 19140, USA.
| | - Ryan Cunningham
- Department of Radiology, Temple University Hospital, 3401 North Broad Street, Philadelphia, PA, 19140, USA
| | - Mamta Amin
- Department of Anatomy, Temple University School of Medicine, 3500 North Broad Street, Philadelphia, PA, 19140, USA
| | - Steven N Popoff
- Department of Anatomy, Temple University School of Medicine, 3500 North Broad Street, Philadelphia, PA, 19140, USA
| | - Feroze Mohamed
- Department of Radiology, Temple University Hospital, 3401 North Broad Street, Philadelphia, PA, 19140, USA
| | - Mary F Barbe
- Department of Anatomy, Temple University School of Medicine, 3500 North Broad Street, Philadelphia, PA, 19140, USA
| |
Collapse
|
20
|
Fang F, Lake SP. Multiscale strain analysis of tendon subjected to shear and compression demonstrates strain attenuation, fiber sliding, and reorganization. J Orthop Res 2015; 33:1704-12. [PMID: 26036894 DOI: 10.1002/jor.22955] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 05/21/2015] [Indexed: 02/04/2023]
Abstract
The manner in which strains are passed down the hierarchical length scales of tendons dictates how cells within the collagen network regulate the tissue response to loading. How tendons deform in different hierarchical levels under shear and compression is unknown. The aims of this study were: (i) to evaluate whether specific regions of bovine deep digital flexor tendons exhibited different strain attenuation from macro to micro length scales, and (ii) to elucidate mechanisms responsible for tendon deformation under shear and compression. Samples from distal and proximal regions of flexor tendons were subjected to three-step incremental stress-relaxation tests. Images of tissue markers, photobleached lines on collagen fibers, and nuclei locations were collected before and after loading. Results showed that strain transfer was attenuated from tissue to local matrix under both shear and compression. Nuclear aspect ratios exhibited smaller changes for distal samples, suggesting that cells are more shielded from deformation in the distal region. Collagen fiber sliding was observed to contribute significantly in response to shear, while uncrimping and fiber reorganization were the predominant mechanisms under compression. This study provides insight into microscale mechanisms responsible for multiscale strain attenuation of tendons under non-tensile macroscale loading.
Collapse
Affiliation(s)
- Fei Fang
- Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, Missouri
| | - Spencer P Lake
- Department of Mechanical Engineering & Materials Science, Washington University, St. Louis, Missouri.,Department of Biomedical Engineering, Washington University, St. Louis, Missouri.,Department of Orthopaedic Surgery, Washington University, St. Louis, Missouri
| |
Collapse
|
21
|
Shearer T. A new strain energy function for modelling ligaments and tendons whose fascicles have a helical arrangement of fibrils. J Biomech 2015; 48:3017-25. [DOI: 10.1016/j.jbiomech.2015.07.032] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Revised: 06/23/2015] [Accepted: 07/27/2015] [Indexed: 10/23/2022]
|
22
|
Walton LA, Bradley RS, Withers PJ, Newton VL, Watson REB, Austin C, Sherratt MJ. Morphological Characterisation of Unstained and Intact Tissue Micro-architecture by X-ray Computed Micro- and Nano-Tomography. Sci Rep 2015; 5:10074. [PMID: 25975937 PMCID: PMC4650804 DOI: 10.1038/srep10074] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Accepted: 03/27/2015] [Indexed: 02/08/2023] Open
Abstract
Characterisation and quantification of tissue structures is limited by sectioning-induced artefacts and by the difficulties of visualising and segmenting 3D volumes. Here we demonstrate that, even in the absence of X-ray contrast agents, X-ray computed microtomography (microCT) and nanotomography (nanoCT) can circumvent these problems by rapidly resolving compositionally discrete 3D tissue regions (such as the collagen-rich adventitia and elastin-rich lamellae in intact rat arteries) which in turn can be segmented due to their different X-ray opacities and morphologies. We then establish, using X-ray tomograms of both unpressurised and pressurised arteries that intra-luminal pressure not only increases lumen cross-sectional area and straightens medial elastic lamellae but also induces profound remodelling of the adventitial layer. Finally we apply microCT to another human organ (skin) to visualise the cell-rich epidermis and extracellular matrix-rich dermis and to show that conventional histological and immunohistochemical staining protocols are compatible with prior X-ray exposure. As a consequence we suggest that microCT could be combined with optical microscopy to characterise the 3D structure and composition of archival paraffin embedded biological materials and of mechanically stressed dynamic tissues such as the heart, lungs and tendons.
Collapse
Affiliation(s)
| | | | | | - Victoria L. Newton
- Institute of Inflammation and Repair, University of Manchester, Manchester, United Kingdom
| | - Rachel E. B. Watson
- Institute of Inflammation and Repair, University of Manchester, Manchester, United Kingdom
| | - Clare Austin
- Institute of Cardiovascular Sciences
- Faculty of Health and Social Care, Edge Hill University, Ormskirk, United Kingdom
| | - Michael J. Sherratt
- Institute of Inflammation and Repair, University of Manchester, Manchester, United Kingdom
| |
Collapse
|
23
|
Kondratko-Mittnacht J, Duenwald-Kuehl S, Lakes R, Vanderby R. Shear load transfer in high and low stress tendons. J Mech Behav Biomed Mater 2015; 45:109-20. [PMID: 25700261 DOI: 10.1016/j.jmbbm.2015.01.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 01/14/2015] [Accepted: 01/29/2015] [Indexed: 10/24/2022]
Abstract
BACKGROUND Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructures (helical versus linear) may redistribute loads differently. METHOD OF APPROACH This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20% to 60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. RESULTS AND CONCLUSIONS Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism.
Collapse
Affiliation(s)
- Jaclyn Kondratko-Mittnacht
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Sarah Duenwald-Kuehl
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Roderic Lakes
- Materials Science Program, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Engineering Physics, University of Wisconsin-Madison, Madison, WI 53705, USA
| | - Ray Vanderby
- Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53705, USA; Department of Orthopedics and Rehabilitation, University of Wisconsin-Madison, Madison, WI 53705, USA; Materials Science Program, University of Wisconsin-Madison, Madison, WI 53705, USA.
| |
Collapse
|
24
|
Abstract
OBJECTIVE The purpose of this article is to review a number of diagnostic pitfalls related to ultrasound evaluation of the hand and wrist. Such pitfalls relate to evaluation of ten-dons (extensor retinaculum, multiple tendon fascicles, tendon subluxation), inflammatory arthritis (incomplete evaluation, misinterpretation of erosions, failure to evaluate for enthesitis), carpal tunnel syndrome (inaccurate measurements, postoperative assessment), ulnar collateral ligament of the thumb (misinterpretation of the adductor aponeurosis and displaced tear), wrist ganglion cysts (incomplete evaluation and misdiagnosis), and muscle variants. CONCLUSION Although ultrasound has been shown to be an effective imaging method for assessment of many pathologic conditions of the wrist, knowledge of potential pitfalls is essential to avoid misdiagnosis and achieve high diagnostic accuracy.
Collapse
|
25
|
Helical sub-structures in energy-storing tendons provide a possible mechanism for efficient energy storage and return. Acta Biomater 2013; 9:7948-56. [PMID: 23669621 DOI: 10.1016/j.actbio.2013.05.004] [Citation(s) in RCA: 92] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2013] [Revised: 04/18/2013] [Accepted: 05/02/2013] [Indexed: 12/26/2022]
Abstract
The predominant function of tendons is to position the limb during locomotion. Specific tendons also act as energy stores. Energy-storing (ES) tendons are prone to injury, the incidence of which increases with age. This is likely related to their function; ES tendons are exposed to higher strains and require a greater ability to recoil than positional tendons. The specialized properties of ES tendons are thought to be achieved through structural and compositional differences. However, little is known about structure-function relationships in tendons. This study uses fascicles from the equine superficial digital flexor (SDFT) and common digital extensor (CDET) as examples of ES and positional tendons. We hypothesized that extension and recoil behaviour at the micro-level would differ between tendon types, and would alter with age in the injury-prone SDFT. Supporting this, the results show that extension in the CDET is dominated by fibre sliding. By contrast, greater rotation was observed in the SDFT, suggesting a helical component to fascicles in this tendon. This was accompanied by greater recovery and less hysteresis loss in SDFT samples. In samples from aged SDFTs, the amount of rotation and the ability to recover decreased, while hysteresis loss increased. These findings indicate that fascicles in the ES SDFT may have a helical structure, enabling the more efficient recoil observed. Further, the helix structure appears to alter with ageing; this coincides with a reduction in the ability of SDFT fascicles to recoil. This may affect tendon fatigue resistance and predispose aged tendons to injury.
Collapse
|