1
|
Guilmin-Crépon S, Carel JC, Schroedt J, Sulmont V, Salmon AS, Le Tallec C, Coutant R, Dalla-Vale F, Stuckens C, Bony-Trifunovic H, Crosnier H, Kurtz F, Kaguelidou F, Le Jeannic A, Durand-Zaleski I, Couque N, Alberti C, Tubiana-Rufi N. Is there an optimal strategy for real-time continuous glucose monitoring in pediatrics? A 12-month French multi-center, prospective, controlled randomized trial (Start-In!). Pediatr Diabetes 2019; 20:304-313. [PMID: 30663187 DOI: 10.1111/pedi.12820] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 11/14/2018] [Accepted: 01/02/2019] [Indexed: 02/06/2023] Open
Abstract
AIM To compare the efficacy of three strategies for real-time continuous glucose monitoring (RT-CGM) over 12 months in children and adolescents with type 1 diabetes. METHODS A French multicenter trial (NCT00949221) with a randomized, controlled, prospective, open, and parallel-group design was conducted. After 3 months of RT-CGM, patients were allocated to one of three groups: return to self-monitoring of blood glucose, continuous CGM (80% of the time), or discontinuous CGM (40% of the time). The primary outcome was hemoglobin A1c (HbA1c) levels from 3 to 12 months. The secondary outcomes were acute metabolic events, hypoglycemia, satisfaction with CGM and cost. RESULTS We included 151 subjects, aged 2 to 17 years, with a mean HbA1c level of 8.5% (SD0.7; 69 mmol/mol). The longitudinal change in HbA1c levels was similar in all three groups, at 3, 6, 9 and 12 months. The medical secondary endpoints did not differ between groups. The rate of severe hypoglycemia was significantly lower than that for the pretreatment year for the entire study population. Subjects reported consistent use and good tolerance of the device, regardless of age or insulin treatment. The use of full-time RT-CGM for 3 months costs the national medical insurance system €2629 per patient. CONCLUSION None of the three long-term RT-CGM strategies evaluated in pediatric type 1 diabetes was superior to the others in terms of HbA1c levels. CGM-use for 3 months decreased rates of severe hypoglycemia. Our results confirm the feasibility of long-term RT-CGM-use and the need to improve educational support for patients and caregivers.
Collapse
Affiliation(s)
- Sophie Guilmin-Crépon
- Pediatric Endocrinology and Diabetology Department and Centre de Référence des Maladies Endocriniennes Rares de la Croissance, CHU Robert Debré, AP-HP, Paris, France.,Unit of Clinical Epidemiology, CHU Robert Debré, APHP, Paris, France.,Inserm, UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France.,University Paris Diderot, Sorbonne Paris Cité, Paris, France
| | - Jean-Claude Carel
- Pediatric Endocrinology and Diabetology Department and Centre de Référence des Maladies Endocriniennes Rares de la Croissance, CHU Robert Debré, AP-HP, Paris, France.,Inserm, PROTECT, Université Paris Diderot, Paris, France.,University Paris Diderot, Sorbonne Paris Cité, Paris, France
| | - Julien Schroedt
- Unit of Clinical Epidemiology, CHU Robert Debré, APHP, Paris, France.,Inserm, UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France
| | | | | | - Claire Le Tallec
- Pediatric Diabetology Unit, Children's Hospital, CHU Toulouse, Toulouse, France
| | - Régis Coutant
- Pediatric Endocrinology and Diabetology Department, CHU Angers, Angers, France
| | - Fabienne Dalla-Vale
- Pediatric Unit, Arnaud de Villeneuve Children's Hospital, CHU Montpellier, Montpellier, France
| | - Chantal Stuckens
- Pediatric Unit, Jeanne de Flandre Hospital, CHU Lille, Lille, France
| | | | - Hélène Crosnier
- Pediatric Unit, Poissy Saint-Germain-en-Laye Hospital, Poissy, France
| | - François Kurtz
- Pediatric Unit, Saint Avold Hospital, Saint-Avold, France
| | | | - Anaïs Le Jeannic
- Inserm, UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France.,Health Economics Clinical Research Platform (URCEco), APHP, Paris, France
| | - Isabelle Durand-Zaleski
- Inserm, UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France.,Health Economics Clinical Research Platform (URCEco), APHP, Paris, France
| | - Nathalie Couque
- Department of Molecular Biochemistry, CHU Robert Debré, APHP, Paris, France
| | - Corinne Alberti
- Unit of Clinical Epidemiology, CHU Robert Debré, APHP, Paris, France.,Inserm, UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France.,University Paris Diderot, Sorbonne Paris Cité, Paris, France
| | - Nadia Tubiana-Rufi
- Pediatric Endocrinology and Diabetology Department and Centre de Référence des Maladies Endocriniennes Rares de la Croissance, CHU Robert Debré, AP-HP, Paris, France.,University Paris Diderot, Sorbonne Paris Cité, Paris, France
| |
Collapse
|
2
|
Guilmin-Crépon S, Carel JC, Schroedt J, Scornet E, Alberti C, Tubiana-Rufi N. How Should We Assess Glycemic Variability in Type 1 Diabetes? Contribution of Principal Component Analysis for Interstitial Glucose Indices in 142 Children. Diabetes Technol Ther 2018; 20:440-447. [PMID: 29923773 DOI: 10.1089/dia.2017.0404] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Glycemic variability (GV) can be used to assess glycemic control in diabetes, but there is no clear consensus concerning the methods to use for its assessment. Methodological differences have resulted in differences in the outcome of GV metrics used in research studies, controversies over clinical impact, and an absence of integration into routine care. AIM To identify the indicators of GV most meaningful for clinicians, patients, and clinical researchers. MATERIALS AND METHODS Continuous glucose monitoring data were collected during the first 3 months of a pediatric diabetes clinical trial (Start-In!; n = 142). We used principal component analysis (PCA) to analyze weekly averages for 22 parameters relating to GV. RESULTS PCA identified five groups of parameters and three components explaining 85.7% of the variance. These components represented the amplitude, direction (hypoglycemia vs. hyperglycemia), and timing (within-day vs. between-days) of glucose excursions. CONCLUSIONS This study provides elements that could make GV parameters more useful in clinical practice and research. No single parameter was sufficient to represent the complexity of GV, but it was possible to restrict the number of indicators required. The five groups of parameters identified by PCA could facilitate the choice of the most relevant outcomes for GV analysis in pediatric diabetes according to the purpose of the analysis (e.g., exploration of GV associated with hypo- or hyperglycemia, with short- or long-term periodicity, or GV in its entirety).
Collapse
Affiliation(s)
- Sophie Guilmin-Crépon
- 1 AP-HP, Hôpital Universitaire Robert Debré , Departement of Pediatric Endocrinology and Diabetology and Centre de référence des Maladies Endocriniennes Rares de la Croissance, Paris, France
- 2 APHP, Hôpital Universitaire Robert Debré, Unit of Clinical Epidemiology , Paris, France
- 3 Inserm , UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France
- 4 Univ Paris Diderot , Sorbonne Paris Cité, UMR-S 1123 ECEVE, Paris, France
| | - Jean-Claude Carel
- 1 AP-HP, Hôpital Universitaire Robert Debré , Departement of Pediatric Endocrinology and Diabetology and Centre de référence des Maladies Endocriniennes Rares de la Croissance, Paris, France
- 4 Univ Paris Diderot , Sorbonne Paris Cité, UMR-S 1123 ECEVE, Paris, France
- 5 Inserm, PROTECT, Université Paris Diderot , Sorbonne Paris Cité, Paris, France
| | - Julien Schroedt
- 2 APHP, Hôpital Universitaire Robert Debré, Unit of Clinical Epidemiology , Paris, France
- 3 Inserm , UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France
| | - Erwan Scornet
- 2 APHP, Hôpital Universitaire Robert Debré, Unit of Clinical Epidemiology , Paris, France
| | - Corinne Alberti
- 2 APHP, Hôpital Universitaire Robert Debré, Unit of Clinical Epidemiology , Paris, France
- 3 Inserm , UMR-S 1123 ECEVE and CIC-EC 1426, Paris, France
- 4 Univ Paris Diderot , Sorbonne Paris Cité, UMR-S 1123 ECEVE, Paris, France
| | - Nadia Tubiana-Rufi
- 1 AP-HP, Hôpital Universitaire Robert Debré , Departement of Pediatric Endocrinology and Diabetology and Centre de référence des Maladies Endocriniennes Rares de la Croissance, Paris, France
| |
Collapse
|
3
|
Maahs DM, Buckingham BA, Castle JR, Cinar A, Damiano ER, Dassau E, DeVries JH, Doyle FJ, Griffen SC, Haidar A, Heinemann L, Hovorka R, Jones TW, Kollman C, Kovatchev B, Levy BL, Nimri R, O'Neal DN, Philip M, Renard E, Russell SJ, Weinzimer SA, Zisser H, Lum JW. Outcome Measures for Artificial Pancreas Clinical Trials: A Consensus Report. Diabetes Care 2016; 39:1175-9. [PMID: 27330126 PMCID: PMC4915553 DOI: 10.2337/dc15-2716] [Citation(s) in RCA: 146] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Research on and commercial development of the artificial pancreas (AP) continue to progress rapidly, and the AP promises to become a part of clinical care. In this report, members of the JDRF Artificial Pancreas Project Consortium in collaboration with the wider AP community 1) advocate for the use of continuous glucose monitoring glucose metrics as outcome measures in AP trials, in addition to HbA1c, and 2) identify a short set of basic, easily interpreted outcome measures to be reported in AP studies whenever feasible. Consensus on a broader range of measures remains challenging; therefore, reporting of additional metrics is encouraged as appropriate for individual AP studies or study groups. Greater consistency in reporting of basic outcome measures may facilitate the interpretation of study results by investigators, regulatory bodies, health care providers, payers, and patients themselves, thereby accelerating the widespread adoption of AP technology to improve the lives of people with type 1 diabetes.
Collapse
Affiliation(s)
- David M Maahs
- Barbara Davis Center for Childhood Diabetes, University of Colorado School of Medicine, Aurora, CO
| | - Bruce A Buckingham
- Division of Pediatric Endocrinology and Diabetes, Department of Pediatric Endocrinology, Stanford University, Stanford, CA
| | - Jessica R Castle
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center, Oregon Health & Science University, Portland, OR
| | - Ali Cinar
- Department of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL
| | - Edward R Damiano
- Department of Biomedical Engineering, Boston University, Boston, MA
| | - Eyal Dassau
- Department of Chemical Engineering, University of California Santa Barbara, Santa Barbara, CA Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| | - J Hans DeVries
- Department of Endocrinology, Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands
| | - Francis J Doyle
- Department of Chemical Engineering, University of California Santa Barbara, Santa Barbara, CA Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA
| | | | - Ahmad Haidar
- Biomedical Engineering Department, McGill University, Montreal, Quebec, Canada Division of Endocrinology, McGill University, Montreal, Quebec, Canada
| | | | - Roman Hovorka
- Wellcome Trust-Medical Research Clinical Institute of Metabolic Science, University of Cambridge, Cambridge, U.K
| | - Timothy W Jones
- Telethon Kids Institute, The University of Western Australia, Perth, Australia
| | | | | | - Brian L Levy
- Johnson & Johnson Diabetes Care Companies, Wayne, PA
| | - Revital Nimri
- Jesse Z and Sara Lea Shafer Institute of Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel, Sackler Faculty of Medicine, Tel Aviv University, Petah Tikva, Israel
| | - David N O'Neal
- Department of Medicine, University of Melbourne, St. Vincent's Hospital Melbourne, Fitzroy, Victoria, Australia
| | - Moshe Philip
- Jesse Z and Sara Lea Shafer Institute of Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel, Sackler Faculty of Medicine, Tel Aviv University, Petah Tikva, Israel
| | - Eric Renard
- Department of Endocrinology, Diabetes, and Nutrition, Montpellier University Hospital, INSERM Clinical Investigation Centre 1411, Institute of Functional Genomics, CNRS UMR 5203, INSERM U1191, University of Montpellier, Montpellier, France
| | - Steven J Russell
- Department of Biomedical Engineering, Boston University, Boston, MA Diabetes Unit and Department of Medicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA
| | | | - Howard Zisser
- Department of Chemical Engineering, University of California Santa Barbara, Santa Barbara, CA
| | - John W Lum
- Jaeb Center for Health Research, Tampa, FL
| |
Collapse
|
4
|
Blauw H, Keith-Hynes P, Koops R, DeVries JH. A Review of Safety and Design Requirements of the Artificial Pancreas. Ann Biomed Eng 2016; 44:3158-3172. [PMID: 27352278 PMCID: PMC5093196 DOI: 10.1007/s10439-016-1679-2] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2016] [Accepted: 06/13/2016] [Indexed: 01/03/2023]
Abstract
As clinical studies with artificial pancreas systems for automated blood glucose control in patients with type 1 diabetes move to unsupervised real-life settings, product development will be a focus of companies over the coming years. Directions or requirements regarding safety in the design of an artificial pancreas are, however, lacking. This review aims to provide an overview and discussion of safety and design requirements of the artificial pancreas. We performed a structured literature search based on three search components—type 1 diabetes, artificial pancreas, and safety or design—and extended the discussion with our own experiences in developing artificial pancreas systems. The main hazards of the artificial pancreas are over- and under-dosing of insulin and, in case of a bi-hormonal system, of glucagon or other hormones. For each component of an artificial pancreas and for the complete system we identified safety issues related to these hazards and proposed control measures. Prerequisites that enable the control algorithms to provide safe closed-loop control are accurate and reliable input of glucose values, assured hormone delivery and an efficient user interface. In addition, the system configuration has important implications for safety, as close cooperation and data exchange between the different components is essential.
Collapse
Affiliation(s)
- Helga Blauw
- Department of Endocrinology, Academic Medical Center, University of Amsterdam, P.O Box 22660, 1100 DD, Amsterdam, The Netherlands. .,Inreda Diabetic BV, Goor, The Netherlands.
| | - Patrick Keith-Hynes
- TypeZero Technologies, LLC, Charlottesville, VA, USA.,Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
| | | | - J Hans DeVries
- Department of Endocrinology, Academic Medical Center, University of Amsterdam, P.O Box 22660, 1100 DD, Amsterdam, The Netherlands
| |
Collapse
|
5
|
Barnard KD, Hood KK, Weissberg-Benchell J, Aldred C, Oliver N, Laffel L. Psychosocial assessment of artificial pancreas (AP): commentary and review of existing measures and their applicability in AP research. Diabetes Technol Ther 2015; 17:295-300. [PMID: 25549042 PMCID: PMC4365433 DOI: 10.1089/dia.2014.0305] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
AIM This study aimed to systematically review the evidence base for the use of existing psychological and psychosocial measures suitable for use in artificial pancreas (AP) research. MATERIALS AND METHODS This systematic review of published literature, gray literature, previous systematic reviews, and qualitative and economic studies was conducted using terms and abbreviations synonymous with diabetes, AP, and quality of life (QoL). RESULTS Two hundred ninety-two abstracts were identified that reported psychosocial assessment of diabetes-related technologies. Of these, nine met the inclusion criteria and were included. Only four of 103 ongoing trials evaluated psychosocial aspects as an outcome in the trial. Of these, treatment satisfaction, acceptance and use intention of AP, fear of hypoglycemia episodes, satisfaction with AP, and an unspecified QoL measure were used. CONCLUSIONS A better understanding of the psychosocial side of AP systems and the extent to which human factors play a role in the uptake and efficient use of these systems will ultimately lead to the most benefit for people with diabetes.
Collapse
Affiliation(s)
- Katharine D. Barnard
- Human Development and Health Academic Unit, Faculty of Medicine, University of Southampton, Southampton, United Kingdom
| | - Korey K. Hood
- Pediatrics, Psychiatry and Behavioral Sciences, Stanford University School of Medicine, Stanford, California
| | - Jill Weissberg-Benchell
- Northwestern University Feinberg School of Medicine, Ann and Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois
| | - Chris Aldred
- Human Development and Health Academic Unit, Faculty of Medicine, University of Southampton, Southampton, United Kingdom
| | - Nick Oliver
- Imperial College London, London, United Kingdom
| | - Lori Laffel
- Joslin Diabetes Center, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
6
|
Abstract
Many studies have tested clinical and behavioral approaches for improving glycemic control in people with diabetes. We reviewed studies to identify how blood glucose (BG) values have been used in patient-focused clinical research and interventions. We sought to describe the frequency that BG values have been the focus of patient education research and to characterize the different methods to integrate BG into an intervention, the approaches implemented to support patient education, and behavior change, and the nature of communication about BG values. Thirty-four eligible studies were identified that included patient education using BG values. Information regarding the study and intervention characteristics include: (1) characteristics of the study sample, (2) how BG values were obtained, (3) use of a graphical interface for BG values, (4) use of a BG log, (5) BG interpretation and regimen adjustments, (6) recommended actions to patient, (7) modality of intervention, and (8) intervention communication schedule. The review demonstrated that new BG technologies provide outstanding opportunities for greater access to BG data, and for patient support and intervention. However, it also indicated a need to improve and expand support for people with diabetes in their daily use of BG values to maintain and improve glycemic control. In order to make the most sustainable impact on behavior, generalizable skills such as problem solving need to be integrated into BG education.
Collapse
Affiliation(s)
- Yaa Kumah-Crystal
- Department of Pediatrics, Vanderbilt University Medical Center, Monroe Carell Jr. Children's Hospital at Vanderbilt, 2200 Children's Way DOT Room 11142-C, Nashville, TN, 37232-9170, USA,
| | | |
Collapse
|
7
|
Bequette BW. Challenges and Recent Progress in the Development of a Closed-loop Artificial Pancreas. ANNUAL REVIEWS IN CONTROL 2012; 36:255-266. [PMID: 23175620 PMCID: PMC3501007 DOI: 10.1016/j.arcontrol.2012.09.007] [Citation(s) in RCA: 85] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Pursuit of a closed-loop artificial pancreas that automatically controls the blood glucose of individuals with type 1 diabetes has intensified during the past six years. Here we discuss the recent progress and challenges in the major steps towards a closed-loop system. Continuous insulin infusion pumps have been widely available for over two decades, but "smart pump" technology has made the devices easier to use and more powerful. Continuous glucose monitoring (CGM) technology has improved and the devices are more widely available. A number of approaches are currently under study for fully closed-loop systems; most manipulate only insulin, while others manipulate insulin and glucagon. Algorithms include on-off (for prevention of overnight hypoglycemia), proportional-integral-derivative (PID), model predictive control (MPC) and fuzzy logic based learning control. Meals cause a major "disturbance" to blood glucose, and we discuss techniques that our group has developed to predict when a meal is likely to be consumed and its effect. We further examine both physiology and device-related challenges, including insulin infusion set failure and sensor signal attenuation. Finally, we discuss the next steps required to make a closed-loop artificial pancreas a commercial reality.
Collapse
|