1
|
Wang Q, Cao Y, Yuan Z, Han M, Zhang Y, Zhuo K, Sun L, Guo X, Zhang H, Jin H. Magnetoelastic Immunosensor for the Rapid Detection of SARS-CoV-2 in Bioaerosols. ACS Sens 2024. [PMID: 39509526 DOI: 10.1021/acssensors.4c01749] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2024]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a protein-coated, single-stranded RNA virus that parasitizes and infects primates, including humans. The current detection methods are mainly carried out using humans as a medium, such as a chest computed tomography (CT) examination, nucleic acid detection, antibody detection, and antigen detection. In addition, SARS-CoV-2 in bioaerosols is an important way of transmission and infection, which has attracted wide attention. In this paper, we simulate a sampling system of SARS-CoV-2 in bioaerosols and detect SARS-CoV-2 in bioaerosols by means of a magnetoelastic (ME) sensing device based on an Android intelligent terminal, which can directly detect SARS-CoV-2 in bioaerosols in a certain unit environment. This approach aims to achieve early detection and prevention. The experimental results show that the sampling system can successfully collect SARS-CoV-2 in bioaerosols. In the linear range of 5-20 ng/mL, the ME sensing detection system results closely match those of the calibration instrument (VNA), with goodness-of-fit values of 0.997 and 0.995, respectively. This work demonstrates that the ME sensing detection system proposed is stable, highly specific, real-time, rapid, and has certain reference values and feasibility.
Collapse
Affiliation(s)
- Qiannan Wang
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Yunmei Cao
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Zhongyun Yuan
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Mengshu Han
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Yunxuan Zhang
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Kai Zhuo
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Lei Sun
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xing Guo
- College of Electronic Information and Optical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- Key Lab of Advanced Transducers and Intelligent Control System of the Ministry of Education, Taiyuan University of Technology, Taiyuan 030024, China
| | - Hongpeng Zhang
- Department of Vascular Surgery, Chinese PLA General Hospital, 100853 Beijing, China
| | - Hu Jin
- Division of Electrical Engineering, Hanyang University, 15588 Ansan, Republic of Korea
| |
Collapse
|
2
|
Yan S, Liu Q, Liang B, Zhang M, Chen W, Zhang D, Wang C, Xing D. Airborne microbes: sampling, detection, and inactivation. Crit Rev Biotechnol 2024:1-35. [PMID: 39128871 DOI: 10.1080/07388551.2024.2377191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 06/05/2024] [Accepted: 06/08/2024] [Indexed: 08/13/2024]
Abstract
The human living environment serves as a habitat for microorganisms and the presence of ubiquitous airborne microbes significantly impacts the natural material cycle. Through ongoing experimentation with beneficial microorganisms, humans have greatly benefited from airborne microbes. However, airborne pathogens endanger human health and have the potential to induce fatal diseases. Tracking airborne microbes is a critical prerequisite for a better understanding of bioaerosols, harnessing their potential advantages, and mitigating associated risks. Although technological breakthroughs have enabled significant advancements in accurately monitoring airborne pathogens, many puzzles about these microbes remain unanswered due to their high variability and environmental diffusibility. Consequently, advanced techniques and strategies for special identification, early warning, and efficient eradication of microbial contamination are continuously being sought. This review presents a comprehensive overview of the research status of airborne microbes, concentrating on the recent advances and challenges in sampling, detection, and inactivation. Particularly, the fundamental design principles for the collection and timely detection of airborne pathogens are described in detail, as well as critical factors for eliminating microbial contamination and enhancing indoor air quality. In addition, future research directions and perspectives for controlling airborne microbes are also suggested to promote the translation of basic research into real products.
Collapse
Affiliation(s)
- Saisai Yan
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Qing Liu
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Bing Liang
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Miao Zhang
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Wujun Chen
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Daijun Zhang
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Chao Wang
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
| | - Dongming Xing
- Qingdao Cancer Institute, The Affiliated Hospital of Qingdao University, Qingdao University, Qingdao, China
- School of Life Sciences, Tsinghua University, Beijing, China
| |
Collapse
|
3
|
Godin R, Hejazi S, Reuel NF. Advancements in Airborne Viral Nucleic Acid Detection with Wearable Devices. ADVANCED SENSOR RESEARCH 2024; 3:2300061. [PMID: 38764891 PMCID: PMC11101210 DOI: 10.1002/adsr.202300061] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Indexed: 05/21/2024]
Abstract
Wearable health sensors for an expanding range of physiological parameters have experienced rapid development in recent years and are poised to disrupt the way healthcare is tracked and administered. The monitoring of environmental contaminants with wearable technologies is an additional layer of personal and public healthcare and is also receiving increased focus. Wearable sensors that detect exposure to airborne viruses could alert wearers of viral exposure and prompt proactive testing and minimization of viral spread, benefitting their own health and decreasing community risk. With the high levels of asymptomatic spread of COVID-19 observed during the pandemic, such devices could dramatically enhance our pandemic response capabilities in the future. To facilitate advancements in this area, this review summarizes recent research on airborne viral detection using wearable sensing devices as well as technologies suitable for wearables. Since the low concentration of viral particles in the air poses significant challenges to detection, methods for airborne viral particle collection and viral sensing are discussed in detail. A special focus is placed on nucleic acid-based viral sensing mechanisms due to their enhanced ability to discriminate between viral subtypes. Important considerations for integrating airborne viral collection and sensing on a single wearable device are also discussed.
Collapse
Affiliation(s)
- Ryan Godin
- Department of Chemical and Biological Engineering, Iowa State University
| | - Sepehr Hejazi
- Department of Chemical and Biological Engineering, Iowa State University
| | - Nigel F. Reuel
- Department of Chemical and Biological Engineering, Iowa State University
| |
Collapse
|
4
|
Rastmanesh A, Boruah JS, Lee MS, Park S. On-Site Bioaerosol Sampling and Airborne Microorganism Detection Technologies. BIOSENSORS 2024; 14:122. [PMID: 38534229 PMCID: PMC10968652 DOI: 10.3390/bios14030122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 02/09/2024] [Accepted: 02/21/2024] [Indexed: 03/28/2024]
Abstract
Bioaerosols are small airborne particles composed of microbiological fragments, including bacteria, viruses, fungi, pollens, and/or by-products of cells, which may be viable or non-viable wherever applicable. Exposure to these agents can cause a variety of health issues, such as allergic and infectious diseases, neurological disorders, and cancer. Therefore, detecting and identifying bioaerosols is crucial, and bioaerosol sampling is a key step in any bioaerosol investigation. This review provides an overview of the current bioaerosol sampling methods, both passive and active, as well as their applications and limitations for rapid on-site monitoring. The challenges and trends for detecting airborne microorganisms using molecular and immunological methods are also discussed, along with a summary and outlook for the development of prompt monitoring technologies.
Collapse
Affiliation(s)
| | | | | | - Seungkyung Park
- Complex Fluids Laboratory, School of Mechanical Engineering, Korea University of Technology and Education, Cheonan 31253, Chungnam, Republic of Korea
| |
Collapse
|
5
|
Moon S. Extending the Shelf-Life of Immunoassay-Based Microfluidic Chips through Freeze-Drying Sublimation Techniques. SENSORS (BASEL, SWITZERLAND) 2023; 23:8524. [PMID: 37896617 PMCID: PMC10610996 DOI: 10.3390/s23208524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2023] [Revised: 10/12/2023] [Accepted: 10/13/2023] [Indexed: 10/29/2023]
Abstract
Point-of-care testing (POCT) platforms utilizing immunoassay-based microfluidic chips offer a robust and specific method for detecting target antibodies, demonstrating a wide range of applications in various medical and research settings. Despite their versatility and specificity, the adoption of these immunoassay chips in POCT has been limited by their short shelf-life in liquid environments, attributed to the degradation of immobilized antibodies. This technical limitation presents a barrier, particularly for resource-limited settings where long-term storage and functionality are critical. To address this challenge, we introduce a novel freeze-dry sublimation process aimed at extending the shelf-life of these microfluidic chips without compromising their functional integrity. This study elaborates on the mechanisms by which freeze-drying preserves the bioactivity of the immobilized antibodies, thereby maintaining the chip's performance over an extended period. Our findings reveal significant shelf-life extension, making it possible for these POCT platforms to be more widely adopted and practically applied, especially in settings with limited resources. This research paves the way for more accessible, long-lasting, and effective POCT solutions, breaking down previous barriers to adoption and application.
Collapse
Affiliation(s)
- Sangjun Moon
- Department of Mechanical Convergence Engineering, Gyeongsang National University, Changwon 51391, Gyeongsangnam-do, Republic of Korea; ; Tel.: +82-55-250-7304; Fax: +82-55-250-7399
- Cybernetics Imaging Systems Co., Ltd., Changwon 51391, Gyeongsangnam-do, Republic of Korea
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| |
Collapse
|
6
|
Wang J, Yang L, Wang H, Wang L. Application of Microfluidic Chips in the Detection of Airborne Microorganisms. MICROMACHINES 2022; 13:1576. [PMID: 36295928 PMCID: PMC9611547 DOI: 10.3390/mi13101576] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/22/2022] [Revised: 09/14/2022] [Accepted: 09/17/2022] [Indexed: 06/16/2023]
Abstract
The spread of microorganisms in the air, especially pathogenic microorganisms, seriously affects people's normal life. Therefore, the analysis and detection of airborne microorganisms is of great importance in environmental detection, disease prevention and biosafety. As an emerging technology with the advantages of integration, miniaturization and high efficiency, microfluidic chips are widely used in the detection of microorganisms in the environment, bringing development vitality to the detection of airborne microorganisms, and they have become a research highlight in the prevention and control of infectious diseases. Microfluidic chips can be used for the detection and analysis of bacteria, viruses and fungi in the air, mainly for the detection of Escherichia coli, Staphylococcus aureus, H1N1 virus, SARS-CoV-2 virus, Aspergillus niger, etc. The high sensitivity has great potential in practical detection. Here, we summarize the advances in the collection and detection of airborne microorganisms by microfluidic chips. The challenges and trends for the detection of airborne microorganisms by microfluidic chips was also discussed. These will support the role of microfluidic chips in the prevention and control of air pollution and major outbreaks.
Collapse
Affiliation(s)
- Jinpei Wang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Engineering Research Center of Personalized Anti-Aging Health Product Development and Transformation, Universities of Shaanxi Province, Xi’an 710077, China
- Applied Research Center for Life Science, Xi’an International University, Xi’an 710077, China
| | - Lixia Yang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Engineering Research Center of Personalized Anti-Aging Health Product Development and Transformation, Universities of Shaanxi Province, Xi’an 710077, China
- Applied Research Center for Life Science, Xi’an International University, Xi’an 710077, China
| | - Hanghui Wang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Xi’an International Medical Center Hospital, Xi’an 710100, China
| | - Lin Wang
- College of Medicine, Xi’an International University, Xi’an 710077, China
- Engineering Research Center of Personalized Anti-Aging Health Product Development and Transformation, Universities of Shaanxi Province, Xi’an 710077, China
- Applied Research Center for Life Science, Xi’an International University, Xi’an 710077, China
| |
Collapse
|
7
|
Ezrre S, Reyna MA, Anguiano C, Avitia RL, Márquez H. Lab-on-a-Chip Platforms for Airborne Particulate Matter Applications: A Review of Current Perspectives. BIOSENSORS 2022; 12:191. [PMID: 35448251 PMCID: PMC9024784 DOI: 10.3390/bios12040191] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 03/12/2022] [Accepted: 03/16/2022] [Indexed: 06/14/2023]
Abstract
Lab-on-a-Chip (LoC) devices are described as versatile, fast, accurate, and low-cost platforms for the handling, detection, characterization, and analysis of a wide range of suspended particles in water-based environments. However, for gas-based applications, particularly in atmospheric aerosols science, LoC platforms are rarely developed. This review summarizes emerging LoC devices for the classification, measurement, and identification of airborne particles, especially those known as Particulate Matter (PM), which are linked to increased morbidity and mortality levels from cardiovascular and respiratory diseases. For these devices, their operating principles and performance parameters are introduced and compared while highlighting their advantages and disadvantages. Discussing the current applications will allow us to identify challenges and determine future directions for developing more robust LoC devices to monitor and analyze airborne PM.
Collapse
Affiliation(s)
- Sharon Ezrre
- Instituto de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21100, Mexico;
| | - Marco A. Reyna
- Instituto de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21100, Mexico;
| | - Citlalli Anguiano
- Facultad de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21280, Mexico; (C.A.); (R.L.A.)
| | - Roberto L. Avitia
- Facultad de Ingeniería, Universidad Autónoma de Baja California (UABC), Mexicali 21280, Mexico; (C.A.); (R.L.A.)
| | - Heriberto Márquez
- Departamento de Óptica, Centro de Investigación Científica y de Educación Superior de Ensenada (CICESE), Ensenada 22860, Mexico;
| |
Collapse
|
8
|
Kim S, Akarapipad P, Nguyen BT, Breshears LE, Sosnowski K, Baker J, Uhrlaub JL, Nikolich-Žugich J, Yoon JY. Direct capture and smartphone quantification of airborne SARS-CoV-2 on a paper microfluidic chip. Biosens Bioelectron 2022; 200:113912. [PMID: 34973565 PMCID: PMC8701770 DOI: 10.1016/j.bios.2021.113912] [Citation(s) in RCA: 19] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 12/20/2021] [Accepted: 12/21/2021] [Indexed: 12/11/2022]
Abstract
SARS, a new type of respiratory disease caused by SARS-CoV, was identified in 2003 with significant levels of morbidity and mortality. The recent pandemic of COVID-19, caused by SARS-CoV-2, has generated even greater extents of morbidity and mortality across the entire world. Both SARS-CoV and SARS-CoV-2 spreads through the air in the form of droplets and potentially smaller droplets (aerosols) via exhaling, coughing, and sneezing. Direct detection from such airborne droplets would be ideal for protecting general public from potential exposure before they infect individuals. However, the number of viruses in such droplets and aerosols is too low to be detected directly. A separate air sampler and enough collection time (several hours) are necessary to capture a sufficient number of viruses. In this work, we have demonstrated the direct capture of the airborne droplets on the paper microfluidic chip without the need for any other equipment. 10% human saliva samples were spiked with the known concentration of SARS-CoV-2 and sprayed to generate liquid droplets and aerosols into the air. Antibody-conjugated submicron particle suspension is then added to the paper channel, and a smartphone-based fluorescence microscope isolated and counted the immunoagglutinated particles on the paper chip. The total capture-to-assay time was <30 min, compared to several hours with the other methods. In this manner, SARS-CoV-2 could be detected directly from the air in a handheld and low-cost manner, contributing to slowing the spread of SARS-CoV-2. We can presumably adapt this technology to a wide range of other respiratory viruses.
Collapse
Affiliation(s)
- Sangsik Kim
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Patarajarin Akarapipad
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Brandon T Nguyen
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Lane E Breshears
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Katelyn Sosnowski
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Jacob Baker
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States
| | - Jennifer L Uhrlaub
- Department of Immunobiology and the University of Arizona Center on Aging, The University of Arizona College of Medicine-Tucson, Tucson, AZ, 85724, United States
| | - Janko Nikolich-Žugich
- Department of Immunobiology and the University of Arizona Center on Aging, The University of Arizona College of Medicine-Tucson, Tucson, AZ, 85724, United States
| | - Jeong-Yeol Yoon
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ, 85721, United States.
| |
Collapse
|
9
|
Bhardwaj J, Hong S, Jang J, Han CH, Lee J, Jang J. Recent advancements in the measurement of pathogenic airborne viruses. JOURNAL OF HAZARDOUS MATERIALS 2021; 420:126574. [PMID: 34252679 PMCID: PMC8256664 DOI: 10.1016/j.jhazmat.2021.126574] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 06/24/2021] [Accepted: 07/02/2021] [Indexed: 05/11/2023]
Abstract
Air-transmissible pathogenic viruses, such as influenza viruses and coronaviruses, are some of the most fatal strains and spread rapidly by air, necessitating quick and stable measurements from sample air volumes to prevent further spread of diseases and to take appropriate steps rapidly. Measurements of airborne viruses generally require their collection into liquids or onto solid surfaces, with subsequent hydrosolization and then analysis using the growth method, nucleic-acid-based techniques, or immunoassays. Measurements can also be performed in real time without sampling, where species-specific determination is generally disabled. In this review, we introduce some recent advancements in the measurement of pathogenic airborne viruses. Air sampling and measurement technologies for viral aerosols are reviewed, with special focus on the effects of air sampling on damage to the sampled viruses and their measurements. Measurement of pathogenic airborne viruses is an interdisciplinary research area that requires understanding of both aerosol technology and biotechnology to effectively address the issues. Hence, this review is expected to provide some useful guidelines regarding appropriate air sampling and virus detection methods for particular applications.
Collapse
Affiliation(s)
- Jyoti Bhardwaj
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | | | - Junbeom Jang
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Chang-Ho Han
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Jaegil Lee
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Jaesung Jang
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea; Department of Biomedical Engineering & Department of Urban and Environmental Engineering, UNIST, Ulsan 44919, Republic of Korea.
| |
Collapse
|
10
|
Krokhine S, Torabi H, Doostmohammadi A, Rezai P. Conventional and microfluidic methods for airborne virus isolation and detection. Colloids Surf B Biointerfaces 2021; 206:111962. [PMID: 34352699 PMCID: PMC8249716 DOI: 10.1016/j.colsurfb.2021.111962] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 06/22/2021] [Accepted: 06/29/2021] [Indexed: 12/23/2022]
Abstract
With the COVID-19 pandemic, the threat of infectious diseases to public health and safety has become much more apparent. Viral, bacterial and fungal diseases have led to the loss of millions of lives, especially in the developing world. Diseases caused by airborne viruses like SARS-CoV-2 are difficult to control, as these viruses are easily transmissible and can circulate in the air for hours. To contain outbreaks of viruses such as SARS-CoV-2 and institute targeted precautions, it is important to detect them in air and understand how they infect their targets. Point-of-care (PoC) diagnostics and point-of-need (PoN) detection methods are necessary to rapidly test patient and environmental samples, so precautions can immediately be applied. Traditional benchtop detection methods such as ELISA, PCR and culture are not suitable for PoC and PoN monitoring, because they can take hours to days and require specialized equipment. Microfluidic devices can be made at low cost to perform such assays rapidly and at the PoN. They can also be integrated with air- and liquid-based sampling technologies to capture and analyze viruses from air and body fluids. Here, conventional and microfluidic virus detection methods are reviewed and compared. The use of air sampling devices to capture and concentrate viruses is discussed first, followed by a review of analysis methods such as immunoassays, RT-PCR and isothermal amplification in conventional and microfluidic platforms. This review provides an overview of the capabilities of microfluidics in virus handling and detection, which will be useful to infectious disease researchers, biomedical engineers, and public health agencies.
Collapse
Affiliation(s)
- Sophie Krokhine
- Faculty of Science, McMaster University, Burke Science Building, 1280 Main Street West, Hamilton, ON L8S 4K1, Canada.
| | - Hadis Torabi
- Department of Biomedical Engineering, University of Isfahan, Iran.
| | | | - Pouya Rezai
- Department of Mechanical Engineering, York University, ON, Canada.
| |
Collapse
|
11
|
Shin J, Kim HR, Bae PK, Yoo H, Kim J, Choi Y, Kang A, Yun WS, Shin YB, Hwang J, Hong S. Reusable surface amplified nanobiosensor for the sub PFU/mL level detection of airborne virus. Sci Rep 2021; 11:16776. [PMID: 34408220 PMCID: PMC8373909 DOI: 10.1038/s41598-021-96254-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 08/06/2021] [Indexed: 11/09/2022] Open
Abstract
We developed a reusable surface-amplified nanobiosensor for monitoring airborne viruses with a sub-PFU/mL level detection limit. Here, sandwich structures consisted of magnetic particles functionalized with antibodies, target viruses, and alkaline phosphatases (ALPs) were formed, and they were magnetically concentrated on Ni patterns near an electrochemical sensor transducer. Then, the electrical signals from electrochemical markers generated by ALPs were measured with the sensor transducer, enabling highly-sensitive virus detection. The sandwich structures in the used sensor chip could be removed by applying an external magnetic field, and we could reuse the sensor transducer chip. As a proof of concepts, the repeated detection of airborne influenza virus using a single sensor chip was demonstrated with a detection limit down to a sub-PFU/mL level. Using a single reusable sensor transducer chip, the hemagglutinin (HA) of influenza A (H1N1) virus with different concentrations were measured down to 10 aM level. Importantly, our sensor chip exhibited reliable sensing signals even after more than 18 times of the repeated HA sensing measurements. Furthermore, airborne influenza viruses collected from the air could be measured down to 0.01 PFU/mL level. Interestingly, the detailed quantitative analysis of the measurement results revealed the degradation of HA proteins on the viruses after the air exposure. Considering the ultrasensitivity and reusability of our sensors, it can provide a powerful tool to help preventing epidemics by airborne pathogens in the future.
Collapse
Affiliation(s)
- Junghyun Shin
- Department of Physics and Astronomy, Seoul National University, Seoul, 08826, Korea
| | - Hyeong Rae Kim
- Gas Metrology Group, Korea Research Institute of Standards and Science (KRISS), Daejeon, 34113, Korea
| | - Pan Kee Bae
- BioNano Health Guard Research Center (H-GUARD), Daejeon, 34141, Korea
| | - Haneul Yoo
- Department of Physics and Astronomy, Seoul National University, Seoul, 08826, Korea
| | - Jeongsu Kim
- Department of Physics and Astronomy, Seoul National University, Seoul, 08826, Korea
| | - Yoonji Choi
- Department of Physics and Astronomy, Seoul National University, Seoul, 08826, Korea
| | - Aeyeon Kang
- Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Korea
| | - Wan S Yun
- Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Korea
| | - Yong Beom Shin
- BioNano Health Guard Research Center (H-GUARD), Daejeon, 34141, Korea.,Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology 10 (KRIBB), Daejeon, 34141, Korea.,Department of Bioengineering, KRIBB School, University of Science and Technology (UST), Daejeon, 34141, Korea
| | - Jungho Hwang
- School of Mechanical Engineering, Yonsei University, Seoul, 03722, Korea
| | - Seunghun Hong
- Department of Physics and Astronomy, and Institute of Applied Physics, Seoul National University, Seoul, 08826, Korea.
| |
Collapse
|
12
|
Wang L, Qi W, Liu Y, Essien D, Zhang Q, Lin J. Recent Advances on Bioaerosol Collection and Detection in Microfluidic Chips. Anal Chem 2021; 93:9013-9022. [PMID: 34160193 DOI: 10.1021/acs.analchem.1c00908] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Bioaerosols containing pathogenic microorganisms have posed a great threat to human and animal health. Effective monitoring of bioaerosols containing pathogenic viruses and bacteria is of great significance to prevent and control infectious diseases. This Feature summarizes recent advances on bioaerosol collection and detection based on microfluidic chips. Besides, the challenges and trends for bioaerosol collection and detection were also discussed.
Collapse
Affiliation(s)
- Lei Wang
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing 100083, China.,Department of Biosystems Engineering, University of Manitoba, Winnipeg, Manitoba R3T 5V6, Canada
| | - Wuzhen Qi
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing 100083, China
| | - Yuanjie Liu
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing 100083, China
| | - Desmond Essien
- Department of Biosystems Engineering, University of Manitoba, Winnipeg, Manitoba R3T 5V6, Canada
| | - Qiang Zhang
- Department of Biosystems Engineering, University of Manitoba, Winnipeg, Manitoba R3T 5V6, Canada
| | - Jianhan Lin
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing 100083, China
| |
Collapse
|
13
|
Castaño N, Cordts SC, Kurosu Jalil M, Zhang KS, Koppaka S, Bick AD, Paul R, Tang SKY. Fomite Transmission, Physicochemical Origin of Virus-Surface Interactions, and Disinfection Strategies for Enveloped Viruses with Applications to SARS-CoV-2. ACS OMEGA 2021; 6:6509-6527. [PMID: 33748563 PMCID: PMC7944398 DOI: 10.1021/acsomega.0c06335] [Citation(s) in RCA: 53] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 02/19/2021] [Indexed: 05/07/2023]
Abstract
Inanimate objects or surfaces contaminated with infectious agents, referred to as fomites, play an important role in the spread of viruses, including SARS-CoV-2, the virus responsible for the COVID-19 pandemic. The long persistence of viruses (hours to days) on surfaces calls for an urgent need for effective surface disinfection strategies to intercept virus transmission and the spread of diseases. Elucidating the physicochemical processes and surface science underlying the adsorption and transfer of virus between surfaces, as well as their inactivation, is important for understanding how diseases are transmitted and for developing effective intervention strategies. This review summarizes the current knowledge and underlying physicochemical processes of virus transmission, in particular via fomites, and common disinfection approaches. Gaps in knowledge and the areas in need of further research are also identified. The review focuses on SARS-CoV-2, but discussion of related viruses is included to provide a more comprehensive review given that much remains unknown about SARS-CoV-2. Our aim is that this review will provide a broad survey of the issues involved in fomite transmission and intervention to a wide range of readers to better enable them to take on the open research challenges.
Collapse
Affiliation(s)
- Nicolas Castaño
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Seth C. Cordts
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Myra Kurosu Jalil
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Kevin S. Zhang
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Saisneha Koppaka
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Alison D. Bick
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Rajorshi Paul
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| | - Sindy K. Y. Tang
- Department
of Mechanical Engineering, Stanford University, Stanford, California 94305, United States
| |
Collapse
|
14
|
Yao L, Zhu W, Shi J, Xu T, Qu G, Zhou W, Yu XF, Zhang X, Jiang G. Detection of coronavirus in environmental surveillance and risk monitoring for pandemic control. Chem Soc Rev 2021; 50:3656-3676. [PMID: 33710177 DOI: 10.1039/d0cs00595a] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
The novel human infectious coronaviruses (CoVs) responsible for severe respiratory syndromes have raised concerns owing to the global public health emergencies they have caused repeatedly over the past two decades. However, the ongoing coronavirus disease 2019 (COVID-19) pandemic induced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has received unprecedented attention internationally. Monitoring pathogenic CoVs in environmental compartments has been proposed as a promising strategy in preventing the environmental spread and tracing of infectious diseases, but a lack of reliable and efficient detection techniques is still a significant challenge. Moreover, the lack of information regarding the monitoring methodology may pose a barrier to primary researchers. Here, we provide a systematic introduction focused on the detection of CoVs in various environmental matrices, comprehensively involving methods and techniques of sampling, pretreatment, and analysis. Furthermore, the review addresses the challenges and potential improvements in virus detection techniques for environmental surveillance.
Collapse
Affiliation(s)
- Linlin Yao
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, P. R. China.
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Bhardwaj SK, Bhardwaj N, Kumar V, Bhatt D, Azzouz A, Bhaumik J, Kim KH, Deep A. Recent progress in nanomaterial-based sensing of airborne viral and bacterial pathogens. ENVIRONMENT INTERNATIONAL 2021; 146:106183. [PMID: 33113463 DOI: 10.1016/j.envint.2020.106183] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 10/03/2020] [Accepted: 10/04/2020] [Indexed: 05/25/2023]
Abstract
Airborne pathogens are small microbes that can cause a multitude of diseases (e.g., the common cold, flu, asthma, anthrax, tuberculosis, botulism, and pneumonia). As pathogens are transmitted from infected hosts via a number of routes (e.g., aerosolization, sneezing, and coughing), there is a great demand to accurately monitor their presence and behavior. Despite such need, conventional detection methods (e.g., colony counting, immunoassays, and various molecular techniques) generally suffer from a number of demerits (e.g., complex, time-consuming, and labor-intensive nature). To help overcome such limitations, nanomaterial-based biosensors have evolved as alternative candidates to realize portable, rapid, facile, and direct on-site identification of target microbes. In this review, nano-biosensors developed for the detection of airborne pathogens are listed and discussed in reference to conventional options. The prospects for the development of advanced nano-biosensors with enhanced accuracy and portability are also discussed.
Collapse
Affiliation(s)
- Sanjeev K Bhardwaj
- Department of Nanomaterials and Application Technology, Center of Innovative and Applied Bioprocessing, Sector 81 (Knowledge City), S.A.S. Nagar 140306, Punjab, India
| | - Neha Bhardwaj
- Department of Biotechnology, University Institute of Engineering and Technology (UIET), Panjab University, Chandigarh 160025, India
| | - Vanish Kumar
- National Agri-Food Biotechnology Institute, S.A.S. Nagar 140306, Punjab, India
| | - Deepanshu Bhatt
- Central Scientific Instruments Organisation, Sector 30 C, Chandigarh 160030, India
| | - Abdelmonaim Azzouz
- Department of Chemistry, Faculty of Science, University of Abdelmalek Essaadi, B.P. 2121, M'Hannech II, 93002 Tétouan, Morocco
| | - Jayeeta Bhaumik
- Department of Nanomaterials and Application Technology, Center of Innovative and Applied Bioprocessing, Sector 81 (Knowledge City), S.A.S. Nagar 140306, Punjab, India
| | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 133-791, Republic of Korea.
| | - Akash Deep
- Central Scientific Instruments Organisation, Sector 30 C, Chandigarh 160030, India.
| |
Collapse
|
16
|
Su X, Sutarlie L, Loh XJ. Sensors and Analytical Technologies for Air Quality: Particulate Matters and Bioaerosols. Chem Asian J 2020; 15:4241-4255. [DOI: 10.1002/asia.202001051] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 10/31/2020] [Indexed: 01/22/2023]
Affiliation(s)
- Xiaodi Su
- Institute of Materials Research and Engineering Agency for Science, Technology and Research 2 Fusionopolis Way, #08-03 Innovis Singapore 138634 Singapore
- Department of Chemistry National University of Singapore, Block S8, Level 3, 3 Singapore Science Drive 3 Singapore
| | - Laura Sutarlie
- Institute of Materials Research and Engineering Agency for Science, Technology and Research 2 Fusionopolis Way, #08-03 Innovis Singapore 138634 Singapore
| | - Xian Jun Loh
- Institute of Materials Research and Engineering Agency for Science, Technology and Research 2 Fusionopolis Way, #08-03 Innovis Singapore 138634 Singapore
| |
Collapse
|
17
|
Bhardwaj J, Kim MW, Jang J. Rapid Airborne Influenza Virus Quantification Using an Antibody-Based Electrochemical Paper Sensor and Electrostatic Particle Concentrator. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:10700-10712. [PMID: 32833440 DOI: 10.1021/acs.est.0c00441] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Airborne influenza viruses are responsible for serious respiratory diseases, and most detection methods for airborne viruses are based on extraction of nucleic acids. Herein, vertical-flow-assay-based electrochemical paper immunosensors were fabricated to rapidly quantify the influenza H1N1 viruses in air after sampling with a portable electrostatic particle concentrator (EPC). The effects of antibodies, anti-influenza nucleoprotein antibodies (NP-Abs) and anti-influenza hemagglutinin antibodies (HA-Abs), on the paper sensors as well as nonpulsed high electrostatic fields with and without corona charging on the virus measurement were investigated. The antigenicity losses of the surface (HA) proteins were caused by H2O2 via lipid oxidation-derived radicals and 1O2 via direct protein peroxidation upon exposure of a high electrostatic field. However, minimal losses in antigenicity of NP of the influenza viruses were observed, and the concentration of the H1N1 viruses was more than 160 times higher in the EPC than the BioSampler upon using NP-Ab based paper sensors after 60 min collection. This NP-Ab-based paper sensors with the EPC provided measurements comparable to quantitative polymerase chain reaction (qPCR) but much quicker, specific to the influenza H1N1 viruses in the presence of other airborne microorganisms and beads, and more cost-effective than enzyme-linked immunosorbent assay and qPCR.
Collapse
Affiliation(s)
- Jyoti Bhardwaj
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Myeong-Woo Kim
- School of Mechanical, Aerospace and Nuclear Engineering, UNIST, Ulsan 44919, Republic of Korea
| | - Jaesung Jang
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
- School of Mechanical, Aerospace and Nuclear Engineering, UNIST, Ulsan 44919, Republic of Korea
| |
Collapse
|
18
|
Kabir E, Azzouz A, Raza N, Bhardwaj SK, Kim KH, Tabatabaei M, Kukkar D. Recent Advances in Monitoring, Sampling, and Sensing Techniques for Bioaerosols in the Atmosphere. ACS Sens 2020; 5:1254-1267. [PMID: 32227840 DOI: 10.1021/acssensors.9b02585] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Bioaerosols in the form of microscopic airborne particles pose pervasive risks to humans and livestock. As either fully active components (e.g., viruses, bacteria, and fungi) or as whole or part of inactive fragments, they are among the least investigated pollutants in nature. Their identification and quantification are essential to addressing related dangers and to establishing proper exposure thresholds. However, difficulties in the development (and selection) of detection techniques and an associated lack of standardized procedures make the sensing of bioaerosols challenging. Through a comprehensive literature search, this review examines the mechanisms of conventional and advanced bioaerosol detection methods. It also provides a roadmap for future research and development in the selection of suitable methodologies for bioaerosol detection. The development of sample collection and sensing technology make it possible for continuous and automated operation. However, intensive efforts should be put to overcome the limitations of current technology as most of the currently available options tend to suffer from lengthy sample acquisition times and/or nonspecificity of probe material.
Collapse
Affiliation(s)
- Ehsanul Kabir
- Department of Farm Power and Machinery, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| | - Abdelmonaim Azzouz
- Department of Chemistry, Faculty of Science, University of Abdelmalek Essaadi, B.P. 2121, M’Hannech II, 93002 Tétouan, Morocco
| | - Nadeem Raza
- Government Emerson College, Bahauddin Zakariya University, Multan 60800, Pakistan
| | - Sanjeev Kumar Bhardwaj
- Center of Innovative and Applied Bioprocessing, (CIAB) [DBT, Govt. of India], Knowledge
City, Sector 81, Mohali, Punjab 140306, India
| | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763, Korea
| | - Meisam Tabatabaei
- Microbial Biotechnology Department, Agricultural Biotechnology Institute of Iran, Agricultural Research, Education, and Extension Organization (AREEO), 31535-1897 Karaj, Iran
| | - Deepak Kukkar
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763, Korea
| |
Collapse
|
19
|
Park KT, Cho DG, Park JW, Hong S, Hwang J. Detection of airborne viruses using electro-aerodynamic deposition and a field-effect transistor. Sci Rep 2015; 5:17462. [PMID: 26642822 PMCID: PMC4672335 DOI: 10.1038/srep17462] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2015] [Accepted: 10/23/2015] [Indexed: 11/09/2022] Open
Abstract
We report a technique for the detection of aerosolized viruses. Conventional field-effect-transistor (FET)-based techniques use solution-based processes, thus require antibody binding to the detection region of the FET prior to the supply of the analyte. With the method described here, virus-antibody-bound particles are delivered to the FET during detection; therefore, neither a pre-treatment antibody binding step on the FET channel nor washing process for virus-antibody-binding are necessary. Our method is based on the concept that virus-antibody-bound particles are larger than the virus or antibody alone, and thus have larger charge numbers following aerosol charging. When these particles are charged by negative ions and electro-aerodynamically deposited on a substrate, there exists a location on the substrate where neither lone virus nor antibody particles land, and where only virus-antibody-bound particles are deposited. If this location coincides with the channel of the FET, the resulting variation in the current can be used to indicate the existence of a virus. By aerosolizing a mixed solution of the virus and the antibody, only the virus-antibody-bound particles were transported to the swCNT-FET, and the electric current in the swCNT-FET decreased to 30% of that measured with no deposited particles.
Collapse
Affiliation(s)
- Kyu-Tae Park
- School of Mechanical Engineering, Yonsei University, Seoul 120-749, Korea
| | - Dong-Guk Cho
- Department of Physics and Astronomy, and Institute of Applied Physics, Seoul National University, Seoul 151-747, Korea
| | - Ji-Woon Park
- School of Mechanical Engineering, Yonsei University, Seoul 120-749, Korea
| | - Seunghun Hong
- Department of Physics and Astronomy, and Institute of Applied Physics, Seoul National University, Seoul 151-747, Korea
| | - Jungho Hwang
- School of Mechanical Engineering, Yonsei University, Seoul 120-749, Korea
| |
Collapse
|
20
|
Fronczek CF, Yoon JY. Biosensors for Monitoring Airborne Pathogens. ACTA ACUST UNITED AC 2015; 20:390-410. [DOI: 10.1177/2211068215580935] [Citation(s) in RCA: 53] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Indexed: 01/15/2023]
|
21
|
|