1
|
Tiew EC, Azis N, Teh LA, Shukor S, Goo CL. An In Vitro Study of Retention and Marginal Adaptation of Endocrowns With Different Intracoronal Depths. Oper Dent 2024; 49:403-411. [PMID: 38978316 DOI: 10.2341/23-063-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/19/2024] [Indexed: 07/10/2024]
Abstract
BACKGROUND Marginal adaptation and retention of endocrowns are crucial for the success and survival of endocrowns. This study aimed to investigate the effect of different materials and intracoronal depth on the retention and marginal adaptation of CAD/CAM fabricated all-ceramic endocrowns. METHODS Thirty-six mandibular premolar teeth with an average surface area of 64.49 mm2 were prepared to receive CAM/CAM fabricated endocrowns. Samples were divided randomly and equally into groups of lithium disilicate with 2 mm intracoronal depth (LD2), lithium disilicate with 4 mm intracoronal depth (LD4), polymer infiltrated ceramic network with 2 mm intracoronal depth (PICN2) and polymer infiltrated ceramic network with 4 mm intracoronal depth (PICN4). All endocrowns were cemented using ParaCore resin cement with 14N pressure and cured for 20 seconds. Fifty measurements of absolute marginal discrepancy (AMD) were done using a stereomicroscope after cementation. After 24 hours, all samples were subjected to thermocycling before the retention test. This involved using a universal testing machine with a crosshead speed of 0.5 mm/min and applying a load of 500N. The maximum force to detach the crown was recorded in newtons and the mode of failure was identified. RESULTS Two-way ANOVA revealed that the AMD for PICN was statistically significantly better than lithium disilicate (p=0.01). No statistically significant difference was detected in the AMD between the two intracoronal depths (p=0.72). PICN and endocrowns with 4 mm intracoronal depth had statistically significant better retention (p<0.05). 72.22% of the sample suffered from cohesive failures and 10 LD endocrowns suffered adhesive failures. CONCLUSIONS Within the limitations of this study, we found that different materials and intracoronal depths can indeed influence the retention of CAD/CAM fabricated endocrowns. Based on the controlled setting findings, PICN was found to have better retention and better marginal adaptation than similar lithium disilicate premolar endocrowns.
Collapse
Affiliation(s)
- E C Tiew
- Eng Cheong Tiew, BDS, MFDS, National University of Malaysia: Universiti Kebangsaan, Malaysia
| | - Nmn Azis
- Nik Madihah Nik Azis, BDS, DClinDent, National University of Malaysia: Universiti Kebangsaan, Malaysia
| | - L A Teh
- Lay Ann Teh, MFD RCS, DClinDent, M Endo RCS, National University of Malaysia: Universiti Kebangsaan, Malaysia
| | - Sna Shukor
- *Siti Nuramanina Abdul Shukor, BDS, MFDSRCS, DClinDent, National University of Malaysia: Universiti Kebangsaan, Malaysia
| | - C L Goo
- Chui Ling Goo, DDS, MDS, MFD RCS, M Pros RCS, National University of Malaysia: Universiti Kebangsaan, Malaysia
| |
Collapse
|
2
|
Manziuc M, Kui A, Chisnoiu A, Labuneț A, Negucioiu M, Ispas A, Buduru S. Zirconia-Reinforced Lithium Silicate Ceramic in Digital Dentistry: A Comprehensive Literature Review of Our Current Understanding. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:2135. [PMID: 38138238 PMCID: PMC10744576 DOI: 10.3390/medicina59122135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 11/26/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023]
Abstract
Zirconia-reinforced lithium silicate (ZLS) ceramic is a new innovative dental material with unique a chemical composition that is designed to combine harmoniously with the appropriate optical properties of lithium disilicate and the enhanced mechanical strength of zirconia. A thorough understanding of ZLS materials is essential for both clinicians and dental technicians. At present, the mechanical behavior and optical properties of the ZLS ceramic system have not been extensively researched, and there is still a lack of consensus regarding the fabrication process and clinical behavior of ZLS all-ceramic restorations. The aim of the present study was to present a selection of comprehensive information concerning zirconia-reinforced lithium silicate ceramics and their optical and mechanical properties, as well as to assess data regarding cementation procedures and clinical outcomes for ZLS all-ceramic restorations. Three electronic databases (PubMed, Web of Science, and the Cochrane Library) were used for the research by two independent reviewers. The search was limited to articles published in the English language, as well as clinical and in vitro studies of color and studies on mechanical behavior and the cementation procedures of ZLS restorations. The exclusion criteria comprised abstracts, questionnaire-based studies, case reports, literature reviews, and studies that were not available in English. Zirconia-reinforced lithium-silicate-based ceramic presents a unique and complex microstructure that increases mechanical resistance but decreases aesthetic appearance, especially its translucency, due to tetragonal zirconia content. A material's thickness, the color of the underlying tooth structure, and the resin cement shade are important factors that influence the final shade and aesthetic appearance of ZLS restorations. Mechanical properties, which are defined by the fracture toughness, flexural strength, elastic modulus, and hardness of ZLS ceramic are higher compared to feldspathic, lithium disilicate, and hybrid ceramics, as well as resin nanoceramics; however, they are lower than translucent or high-translucency zirconia. Acid etching, sandblasting, and laser etching represent the most used methods to prepare the ZLS restoration surfaces for proper bonding procedures.
Collapse
Affiliation(s)
| | - Andreea Kui
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (M.M.); (S.B.)
| | | | | | | | | | | |
Collapse
|
3
|
Sağlam G, Cengiz S, Köroğlu A, Şahin O, Velioğlu N. Comparison of the Micro-Shear Bond Strength of Resin Cements to CAD/CAM Glass Ceramics with Various Surface Treatments. MATERIALS (BASEL, SWITZERLAND) 2023; 16:2635. [PMID: 37048927 PMCID: PMC10095943 DOI: 10.3390/ma16072635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/15/2023] [Accepted: 03/24/2023] [Indexed: 06/19/2023]
Abstract
This study aimed to compare the effect of acid etching, sandblasting, or silica coating on the micro-shear bond strength of dual-cured resin cements to computer-aided design and computer-aided manufacturing (CAD/CAM) glass ceramic materials. Feldspathic, lithium disilicate, and zirconia-reinforced CAD/CAM ceramics were divided into four groups: control group (C), no surface treatment; hydrofluoric (HF) group, 5% HF acid-etched; sandblasting (SB) group, abraded with 50 µm aluminum oxide (Al2O3) particles; silica-coated (CJ) group, abraded with 30 µm silica-modified Al2O3 particles. Roughness values were obtained by using a profilometer. The cements were condensed on the surface-treated specimens and a micro-shear bond test was conducted. The ceramic material (p < 0.001) and surface treatment type (p < 0.001) significantly affected the micro-shear bond strength values. HF acid etching can be recommended for the surface pretreatment of feldspathic, lithium disilicate, and zirconia-reinforced CAD/CAM ceramics. Better bond strengths can be obtained with HF acid etching than with sandblasting and silica coating.
Collapse
Affiliation(s)
- Gaye Sağlam
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak 67600, Turkey
| | - Seda Cengiz
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak 67600, Turkey
| | - Ayşegül Köroğlu
- Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak 67600, Turkey
| | - Onur Şahin
- Department of Prosthodontics, DCT Clinic, Antalya 07000, Turkey
| | - Neslin Velioğlu
- Department of Prosthodontics, Navadent Oral and Dental Health Policlinic, Zonguldak 67000, Turkey
| |
Collapse
|
4
|
Effects of Two Different Acid Etching and Surface Washing Methods on Bond Strength on Different CAD-CAM Blocks under Aging Protocols. BIOMED RESEARCH INTERNATIONAL 2023. [DOI: 10.1155/2023/7982813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Aim. The purpose of this study is to investigate the effects of hydrofluoric acid and one-component ceramic primer and silane (Monobond Etch and Prime (MEP)) applications on lithium disilicate glass ceramics and zirconium-infiltrated lithium silicate glass ceramics, as well as the effect of ultrasonic and phosphoric acid surface washing methods on bond strength. Materials and Method. A total of 240 ceramic samples were prepared using two different CAD-CAM material blocks with a thickness of 2 mm made of lithium disilicate glass-ceramic (IPS e.max CAD) and zirconium-infiltrated lithium silicate glass ceramic blocks (Celtra Duo). The samples were cemented to the composite discs (Tetric N-Ceram) after two different acid treatments, and surface washing processes were applied to them. As such, 24 groups were formed, each with two different acid applications, three different washing processes, two different CAD-CAM blocks, and two different aging procedures (
). Following the application of the acid, different washing processes are used. These were HF acid and washing only (HF + W), HF acid and ultrasonic washing (HF + US), HF acid and phosphoric acid (HF + PA), MEP with washing only (MEP + W), MEP and ultrasonic washing (MEP + US), and MEP and phosphoric acid (MEP + PA). The composite discs were cemented with dual cure adhesive cement (Multilink Automix) after the determined surface treatments were applied to the blocks. After surface applications, SEM analysis was conducted. Following exposure to two different thermal procedures, long-term (TL) and short-term (TS), bond strengths were measured using an Instron universal test device. SPSS version 23.0 software was used to perform the statistical analyses. Histogram graphs and the Kolmogorov-Smirnov/Shapiro-Wilk test were used to assess the variables’ conformity to the normal distribution. Results. The bond strength values of TS and TL in the Celtra Duo block were significantly higher than those in the e.max CAD block (
). The TS-TL bonding strength value difference in the e.max CAD block was significantly higher than the surface measurements in the Celtra Duo block. While the highest bond strength value HF + US for TS in e.max CAD was
, the values of HF + US in Celtra Duo were significantly higher in terms of TL values when compared to other groups. Conclusion. Celtra Duo material demonstrated higher bond strength values after a short and long thermal cycle than e.max CAD material. In general, groups bonded with HF were less affected by the thermal cycle than groups treated with MEP.
Collapse
|
5
|
Al Ahmari NM, Alahmari MA, Al Moaleem MM, Alshahrani RSA, Alqahtani FF, Mohammed WS, Al-Makramani BMA, Mehta V, Meto A, Meto A. Physical, Optical, and Mechanical Properties of Ceramic Materials after Coffee Immersion and Evaluation of Cleaning Impact with Different Oral Hygiene Tools. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:15047. [PMID: 36429767 PMCID: PMC9690395 DOI: 10.3390/ijerph192215047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/13/2022] [Accepted: 11/13/2022] [Indexed: 06/16/2023]
Abstract
This study aimed to evaluate the effect of three oral hygiene tools, a regular toothbrush, an electronic toothbrush, and mouthwash, on the color stability of three different computer-aided design (CAD) and computer-aided manufactured (CAM) ceramic blocks. Feldspathic ceramic (Vita Triluxe Forte), hybrid resin ceramic (Vita Enamic), and lithium disilicate glass-ceramic (IPS e.max CAD) were used in this study. A CAD/CAM system and 81 (27 of each material) samples of ceramic blocks were used. All samples were immersed in black coffee for 15 days, and the coffee was changed twice per day. Using a spectrophotometer probe, samples on a grey background were scanned, and physical properties like surface hardness and depth were measured using interferometry and a 3D non-contact surface metrology. After 30 days of application of oral hygiene tools, instruments were used to measure various physical, mechanical, and optical properties. Vita Triluxe had the highest average color variation values (ΔE00) after 15 and 30 days of immersion in coffee in both regular and electronic toothbrushes. Moreover, IPS e.max CAD had the least ΔE00 values with no significant differences among the groups. The surface roughness (Ra) of the Vita Enamic ceramic increased when using a regular toothbrush, and the surface height (Rz) for the Vita Enamic ceramic increased when an electronic toothbrush was used. IPS e.max CAD had the greatest modules of elasticity forces, and Vita Triluxe Forte had the lowest when used with a regular toothbrush. The ΔE00 values of the tested materials were minimally increased or decreased after 30 days of cleaning, and all were clinically acceptable. Ra and Rz were the highest for Vita Enamic in comparison to the other groups. The highest percentage in IPS e.max CAD was associated with a type 1 fracture, whereas type 3 was predominantly observed with Vita Enamic, and type 2 in the Vita Triluxe group without significant differences.
Collapse
Affiliation(s)
- Nasser M. Al Ahmari
- Prosthetic Department, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Maram A. Alahmari
- Saudi Board Prosthodontic Resident, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Mohammed M. Al Moaleem
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
- Faculty of Dentistry, University of Ibn al-Nafis for Medical Sciences, Sana’a 4337, Yemen
| | | | - Fatimah F. Alqahtani
- Dental Interns, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Waad Saeed Mohammed
- Dental Interns, College of Dentistry, King Khalid University, Abha 62529, Saudi Arabia
| | - Bandar M. A. Al-Makramani
- Department of Prosthetic Dental Science, College of Dentistry, Jazan University, Jazan 45142, Saudi Arabia
| | - Vini Mehta
- Department of Public Health Dentistry, Dr. D.Y. Patil Dental College and Hospital, Dr. D.Y. Patil Vidyapeeth, Pune 411018, India
| | - Aida Meto
- Department of Dentistry, Faculty of Dental Sciences, University of Aldent, 1007 Tirana, Albania
- Clinical Microbiology, School of Dentistry, University of Modena and Reggio Emilia, 41125 Modena, Italy
| | - Agron Meto
- Department of Dentistry, Faculty of Dental Sciences, University of Aldent, 1007 Tirana, Albania
| |
Collapse
|
6
|
Hassan SA, Beleidy M, El-din YA. Biocompatibility and Surface Roughness of Different Sustainable Dental Composite Blocks: Comprehensive In Vitro Study. ACS OMEGA 2022; 7:34258-34267. [PMID: 36188235 PMCID: PMC9520711 DOI: 10.1021/acsomega.2c03745] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Accepted: 09/06/2022] [Indexed: 06/16/2023]
Abstract
The study purposed to investigate the biocompatibility and sustainability of two computer-aided design/computer-aided manufacturing (CAD/CAM) resin-based composites compared to a resin-modified ceramic in terms of surface roughness, biofilm formation, cytotoxicity, genotoxicity, and cellular changes observed under transmission electron microscopy (TEM). Three CAD/CAM blocks were used, two resin-based composites [Brilliant Crios (BC) and Cerasmart, (CS) and one hybrid ceramic (Vita Enamic (EN)]. Each block was sectioned into 10 × 12 × 2 mm specimens, followed by finishing and polishing. Each specimen was evaluated for surface roughness using 3D optical profilometry and scanned by scanning electron microscopy. Biofilm formation and its relation to surface roughness have been investigated for all tested materials. A Hep-2 cell line was used to investigate the viability through MTT assay. The cytotoxicity of the materials was measured at 24, 48, and 168 h. The activity of P53, caspase 3, and cytochrome C was evaluated to detect the genotoxicity of different groups, followed by TEM tracking of the cellular changes. Statistical analysis was implemented by utilizing a one-way analysis of variance test. The significance was set at P ≤ 0.05. With regard to the surface roughness, no statistically significant differences were shown between groups. BC possessed the highest biofilm formation value, followed by EN and CS, with no significance between them. No correlation between surface roughness of tested materials and biofilm formation was shown. Considering viability, the highest values were recorded for EN, whereas BC showed the lowest values. P53-fold changes in EN were significantly the lowest, indicating less genotoxicity. Within the current study's limitations, BC showed the highest biofilm formation. However, no significant surface roughness difference or correlation with biofilm formation was observed in tested materials. EN showed the lowest cytotoxicity and the highest viability. EN revealed the best compatibility performance among tested materials. On the contrary, the BC exhibited fewer preferences.
Collapse
Affiliation(s)
- Soha A. Hassan
- Associate
Professor of Cell Biology and Genetics Faculty of Dentistry-October
6 University, Giza 12511, Egypt
| | - Marwa Beleidy
- Lecturer
of Fixed Prosthodontics, Faculty of Dentistry, October 6 University, Giza 12511, Egypt
| | - Yasmine Alaa El-din
- Lecturer
of Oral & Maxillofacial Pathology, Faculty of Dentistry, October 6 University, Giza 12511, Egypt
| |
Collapse
|
7
|
Jovanović M, Živić M, Milosavljević M. A potential application of materials based on a polymer and CAD/CAM composite resins in prosthetic dentistry. J Prosthodont Res 2020; 65:137-147. [PMID: 32981910 DOI: 10.2186/jpr.jpor_2019_404] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE A bioactive high performance polymer (BioHPP) and computer-aided design/computer-aided manufacturing (CAD/CAM) composite resin materials are a relatively new class of dental biomaterials, that are biocompatible and have good aesthetic features. In this review paper, we will summarize literature and publication data on the characteristics of the mentioned materials, as well as their potential application in the dental prosthetics. STUDY SELECTION Available studies and literature reviews from PubMed, SCIndex, Scopus and Google Scholar corresponding to polyetheretherketone (PEEK), high-performance polymers, reinforced composite materials, composite materials, resins, glass-fiber reinforced materials, CAD/CAM materials, dental implants, removable and fixed dental were reviewed. RESULTS To avoid many disadvantages of metals and their alloys in dental practice, such as inadequate color, high density, thermal conductivity and possible allergic reactions, materials based on polymers (such as BioHPP), and CAD/CAM composite resins are being developed. These materials have significantly better aesthetics and physical-mechanical properties. They are biocompatible materials that are lightweight, resistant, durable, exhibit high bending and compression resistance. CONCLUSIONS The use of CAD/CAM composite resin materials and BioHPP in dentistry has begun recently, so the data about their potential clinical use are limited. Most of their features have been demonstrated through laboratory testing, while clinical studies are relatively scarce, so the need for further clinical trials is emphasized.
Collapse
Affiliation(s)
- Milica Jovanović
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Kragujevac
| | - Miloš Živić
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Kragujevac
| | - Marko Milosavljević
- Department of Dentistry, Faculty of Medical Sciences, University of Kragujevac, Kragujevac
| |
Collapse
|