Lam NN, Murray R, Docherty PD. Evolving Improved Sampling Protocols for Dose-Response Modelling Using Genetic Algorithms with a Profile-Likelihood Metric. Bull Math Biol 2024; 86:70. [PMID: 38717656 PMCID: PMC11078857 DOI: 10.1007/s11538-024-01304-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 04/23/2024] [Indexed: 05/12/2024]
Abstract
Practical limitations of quality and quantity of data can limit the precision of parameter identification in mathematical models. Model-based experimental design approaches have been developed to minimise parameter uncertainty, but the majority of these approaches have relied on first-order approximations of model sensitivity at a local point in parameter space. Practical identifiability approaches such as profile-likelihood have shown potential for quantifying parameter uncertainty beyond linear approximations. This research presents a genetic algorithm approach to optimise sample timing across various parameterisations of a demonstrative PK-PD model with the goal of aiding experimental design. The optimisation relies on a chosen metric of parameter uncertainty that is based on the profile-likelihood method. Additionally, the approach considers cases where multiple parameter scenarios may require simultaneous optimisation. The genetic algorithm approach was able to locate near-optimal sampling protocols for a wide range of sample number (n = 3-20), and it reduced the parameter variance metric by 33-37% on average. The profile-likelihood metric also correlated well with an existing Monte Carlo-based metric (with a worst-case r > 0.89), while reducing computational cost by an order of magnitude. The combination of the new profile-likelihood metric and the genetic algorithm demonstrate the feasibility of considering the nonlinear nature of models in optimal experimental design at a reasonable computational cost. The outputs of such a process could allow for experimenters to either improve parameter certainty given a fixed number of samples, or reduce sample quantity while retaining the same level of parameter certainty.
Collapse
Affiliation(s)
- Nicholas N Lam
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
| | - Rua Murray
- School of Mathematics and Statistics, University of Canterbury, Christchurch, New Zealand
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Baden-Württemberg, Germany
| |
Collapse
|
2
|
Zhou T, Boettger M, Knopp J, Lange M, Heep A, Chase JG. Model-based subcutaneous insulin for glycemic control of pre-term infants in the neonatal intensive care unit. Comput Biol Med 2023; 160:106808. [PMID: 37163965 DOI: 10.1016/j.compbiomed.2023.106808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 03/02/2023] [Accepted: 03/20/2023] [Indexed: 03/30/2023]
Abstract
Hyperglycaemia is a common problem in neonatal intensive care units (NICUs). Achieving good control can result in better outcomes for patients. However, good control is difficult, where poor control and resulting hypoglycaemia reduces outcomes and confounds results. Clinically validated models can provide good control, and subcutaneous insulin delivery can provide more options for insulin therapy for clinicians. However, this combination has only been significantly utilised in adult outpatient diabetes, but could hold benefit for treating NICU infants. This research combines a well-validated NICU metabolic model with subcutaneous insulin kinetics models to assess the feasibility of a model-based approach. Clinical data from 12 very/extremely pre-mature infants was collected for an average study duration of 10.1 days. Blood glucose, interstitial and plasma insulin, as well as subcutaneous and local insulin were modelled, and patient-specific insulin sensitivity profiles were identified for each patient. Modelling error was low, where the cohort median [IQR] mean percentage error was 0.8 [0.3 3.4] %. For external validation, insulin sensitivity was compared to previous NICU cohorts using the same metabolic model, where overall levels of insulin sensitivity were similar. Overall, the combined system model accurately captured observed glucose and insulin dynamics, showing the potential for a model-based approach to glycaemic control using subcutaneous insulin in this cohort. The results justify further model validation and clinical trial research to explore a model-based protocol.
Collapse
|
3
|
Yahia A, Szlávecz Á, Knopp JL, Norfiza Abdul Razak N, Abu Samah A, Shaw G, Chase JG, Benyo B. Estimating Enhanced Endogenous Glucose Production in Intensive Care Unit Patients with Severe Insulin Resistance. J Diabetes Sci Technol 2022; 16:1208-1219. [PMID: 34078114 PMCID: PMC9445352 DOI: 10.1177/19322968211018260] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Critically ill ICU patients frequently experience acute insulin resistance and increased endogenous glucose production, manifesting as stress-induced hyperglycemia and hyperinsulinemia. STAR (Stochastic TARgeted) is a glycemic control protocol, which directly manages inter- and intra- patient variability using model-based insulin sensitivity (SI). The model behind STAR assumes a population constant for endogenous glucose production (EGP), which is not otherwise identifiable. OBJECTIVE This study analyses the effect of estimating EGP for ICU patients with very low SI (severe insulin resistance) and its impact on identified, model-based insulin sensitivity identification, modeling accuracy, and model-based glycemic clinical control. METHODS Using clinical data from 717 STAR patients in 3 independent cohorts (Hungary, New Zealand, and Malaysia), insulin sensitivity, time of insulin resistance, and EGP values are analyzed. A method is presented to estimate EGP in the presence of non-physiologically low SI. Performance is assessed via model accuracy. RESULTS Results show 22%-62% of patients experience 1+ episodes of severe insulin resistance, representing 0.87%-9.00% of hours. Episodes primarily occur in the first 24 h, matching clinical expectations. The Malaysian cohort is most affected. In this subset of hours, constant model-based EGP values can bias identified SI and increase blood glucose (BG) fitting error. Using the EGP estimation method presented in these constrained hours significantly reduced BG fitting errors. CONCLUSIONS Patients early in ICU stay may have significantly increased EGP. Increasing modeled EGP in model-based glycemic control can improve control accuracy in these hours. The results provide new insight into the frequency and level of significantly increased EGP in critical illness.
Collapse
Affiliation(s)
- Anane Yahia
- Department of Control Engineering and Information Technology, Budapest University of Technology and Economics, Budapest, Hungary
- Anane Yahia, Department of Control Engineering and Information Technology, Budapest University of Technology and Economics, 2. Magyar tudosok Blvd., Budapest, H-1117, Hungary.
| | - Ákos Szlávecz
- Department of Control Engineering and Information Technology, Budapest University of Technology and Economics, Budapest, Hungary
| | - Jennifer L. Knopp
- Mechanical Engineering, Centre of Bio-Engineering, University of Canterbury, Christchurch, NZ
| | | | - Asma Abu Samah
- Institute of Energy Infrastructure, Universiti Tenaga Nasional, Jalan Ikram-UNITEN, Kajang, Selangor, Malaysia
| | - Geoff Shaw
- Mechanical Engineering, Centre of Bio-Engineering, University of Canterbury, Christchurch, NZ
| | - J. Geoffrey Chase
- Mechanical Engineering, Centre of Bio-Engineering, University of Canterbury, Christchurch, NZ
| | - Balazs Benyo
- Department of Control Engineering and Information Technology, Budapest University of Technology and Economics, Budapest, Hungary
| |
Collapse
|
4
|
McHugh AD, Chase JG, Knopp JL, Ormsbee JJ, Kulawiec DG, Merry TL, Murphy R, Shepherd PR, Burden HJ, Docherty PD. The Impact of Exogenous Insulin Input on Calculating Hepatic Clearance Parameters. J Diabetes Sci Technol 2022; 16:945-954. [PMID: 33478257 PMCID: PMC9264438 DOI: 10.1177/1932296820986878] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE Model-based metabolic tests require accurate identification of subject-specific parameters from measured assays. Insulin assays are used to identify insulin kinetics parameters, such as general and first-pass hepatic clearances. This study assesses the impact of intravenous insulin boluses on parameter identification precision. METHOD Insulin and C-peptide data from two intravenous glucose tolerance test (IVGTT) trials of healthy adults (N = 10 × 2; denoted A and B), with (A) and without (B) insulin modification, were used to identify insulin kinetics parameters using a grid search. Monte Carlo analysis (N = 1000) quantifies variation in simulation error for insulin assay errors of 5%. A region of parameter values around the optimum was identified whose errors are within variation due to assay error. A smaller optimal region indicates more precise practical identifiability. Trial results were compared to assess identifiability and precision. RESULTS Trial B, without insulin modification, has optimal parameter regions 4.7 times larger on average than Trial A, with 1-U insulin bolus modification. Ranges of optimal parameter values between trials A and B increase from 0.04 to 0.12 min-1 for hepatic clearance and from 0.07 to 0.14 for first-pass clearance on average. Trial B's optimal values frequently lie outside physiological ranges, further indicating lack of distinct identifiability. CONCLUSIONS A small 1-U insulin bolus improves identification of hepatic clearance parameters by providing a smaller region of optimal parameter values. Adding an insulin bolus in metabolic tests can significantly improve identifiability and outcome test precision. Assay errors necessitate insulin modification in clinical tests to ensure identifiability and precision.
Collapse
Affiliation(s)
- Alexander D. McHugh
- Centre for Bioengineering, Department of
Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
- Alexander D. McHugh, BE(Hons),
Centre for Bioengineering, Department of Mechanical Engineering,
University of Canterbury, Level 5 Civil/Mechanical Building, Private Bag 4800,
Christchurch, 8140, New Zealand.
| | - J. Geoffrey Chase
- Centre for Bioengineering, Department of
Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Jennifer L. Knopp
- Centre for Bioengineering, Department of
Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Jennifer J. Ormsbee
- Centre for Bioengineering, Department of
Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Diana G. Kulawiec
- Department of Biomedical Engineering,
Rochester Institute of Technology, Rochester, NY, USA
| | - Troy L. Merry
- Discipline of Nutrition, Faculty of
Medical and Health Sciences, University of Auckland, Auckland, New Zealand
- Maurice Wilkins Centre for Molecular
Biodiscovery, University of Auckland, Auckland, New Zealand
| | - Rinki Murphy
- Discipline of Nutrition, Faculty of
Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Peter R. Shepherd
- Discipline of Nutrition, Faculty of
Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Hannah J. Burden
- Discipline of Nutrition, Faculty of
Medical and Health Sciences, University of Auckland, Auckland, New Zealand
| | - Paul D. Docherty
- Centre for Bioengineering, Department of
Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
- Institute for Technical Medicine,
Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
5
|
McHugh AD, Chase JG, Knopp JL, Zhou T, Holder-Pearson L. Determining Losses in Jet Injection Subcutaneous Insulin Delivery: A Model-Based Approach. J Diabetes Sci Technol 2022:19322968221085032. [PMID: 35343255 DOI: 10.1177/19322968221085032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Accurate, safe glycemic management requires reliable delivery of insulin doses. Insulin can be delivered subcutaneously for action over a longer period of time. Needle-free jet injectors provide subcutaneous (SC) delivery without requiring needle use, but the volume of insulin absorbed varies due to losses associated with the delivery method. This study employs model-based methods to determine the expected proportion of active insulin present from a needle-free SC dose. METHODS Insulin, C-peptide, and glucose assay data from a frequently sampled insulin-modified oral glucose tolerance test trial with 2U SC insulin delivery, paired with a well-validated metabolic model, predict metabolic outcomes for N = 7 healthy adults. Subject-specific nonlinear hepatic clearance profiles are modeled over time using third-order basis splines with knots located at assay times. Hepatic clearance profiles are constrained within a physiological rate of change, and relative to plasma glucose profiles. Insulin loss proportions yielding optimal insulin predictions are then identified, quantifying delivery losses. RESULTS Optimal parameter identification suggests losses of up to 22% of the nominal 2U SC dose. The degree of loss varies between subjects and between trials on the same subject. Insulin fit accuracy improves where loss greater than 5% is identified, relative to where delivery loss is not modeled. CONCLUSIONS Modeling shows needle-free SC jet injection of a nominal dose of insulin does not necessarily provide metabolic action equivalent to total dose, and this availability significantly varies between trials. By quantifying and accounting for variability of jet injection insulin doses, better glycemic management outcomes using SC jet injection may be achieved.
Collapse
Affiliation(s)
- Alexander D McHugh
- Centre for Bioengineering, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - J Geoffrey Chase
- Centre for Bioengineering, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Jennifer L Knopp
- Centre for Bioengineering, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Tony Zhou
- Centre for Bioengineering, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Lui Holder-Pearson
- Centre for Bioengineering, Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
6
|
Prediction and estimation of pulmonary response and elastance evolution for volume-controlled and pressure-controlled ventilation. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2021.103367] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
7
|
Quantifying ventilator unloading in CPAP ventilation. Comput Biol Med 2022; 142:105225. [PMID: 35032739 DOI: 10.1016/j.compbiomed.2022.105225] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2021] [Revised: 01/04/2022] [Accepted: 01/04/2022] [Indexed: 11/21/2022]
Abstract
BACKGROUND The intrinsic (muscular) patient effort driving inspiration in non-invasive ventilation modes, such as continuous positive airway pressure (CPAP) therapy, has not been identified from non-invasive data. Current CPAP settings are based on clinical judgment and assessment of symptoms of respiratory distress. Non-optimal settings, including too much positive end expiratory pressure (PEEP) can cause unintended lung injury and ventilator unloading, where patient effort drops and the CPAP device enables too much work being imposed on the injured lung. Currently, there is no non-invasive means of quantifying or identifying these effects. METHODS A novel model-based method of ascertaining intrinsic patient work of breathing (WOB) in CPAP is developed based on linear single compartment and 2nd order b-spline models previously used in invasive ventilation modes. Results are compared to current clinical indications, such as total Imposed WOB from the CPAP device and beak length, the latter of which is the clinical metric used to indicate alveolar overdistension. Intrinsic and Imposed WOB are compared. The hypothesis is that ventilator unloading can be assessed as a decrease in Intrinsic WOB relative to Imposed WOB, as PEEP and associated ventilator unloading rise. This hypothesis is tested using 14 subjects from a CPAP trial of several breathing rates at two PEEP levels. RESULTS The ratio of Intrinsic to Imposed WOB, normalised per unit tidal volume, decreased with increasing PEEP (4-7 cm H2O), capturing the expected trend of ventilator unloading. Ventilator unloading was observed across all breathing rates. Beak length measurements showed no conclusive evidence of capturing overdistension at higher PEEP or ventilator unloading. CONCLUSIONS Patient Intrinsic WOB in CPAP was non-invasively quantified using model-based methods, based on pressure and flow measurements. The ratio of Intrinsic to Imposed WOB per unit tidal volume clearly and consistently showed ventilator unloading across all patients and breathing rates, with Intrinsic WOB decreasing with increasing PEEP. This trend was not observed in the current clinical metric of beak length. Non-invasively quantifying Intrinsic WOB and ventilator unloading is the critical first step to objectively optimising clinical CPAP settings, patient care, and outcomes.
Collapse
|
8
|
Knopp JL, Chase JG, Kim KT, Shaw GM. Model-based estimation of negative inspiratory driving pressure in patients receiving invasive NAVA mechanical ventilation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 208:106300. [PMID: 34348200 DOI: 10.1016/j.cmpb.2021.106300] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 07/17/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND Optimisation of mechanical ventilation (MV) and weaning requires insight into underlying patient breathing effort. Current identifiable models effectively describe lung mechanics, such as elastance (E) and resistance (R) at the bedside in sedated patients, but are less effective when spontaneous breathing is present. This research derives and regularises a single compartment model to identify patient-specific inspiratory effort. METHODS Constrained second-order b-spline basis functions (knot width 0.05 s) are used to describe negative inspiratory drive (Pp, cmH2O) as a function of time. Breath-breath Pp are identified with single E and R values over inspiration and expiration from n = 20 breaths for N = 22 patients on NAVA ventilation. Pp is compared to measured electrical activity of the diaphragm (Eadi) and published results. RESULTS Average per-patient root-mean-squared model fit error was (median [interquartile range, IQR]) 0.9 [0.6-1.3] cmH2O, and average per-patient median Pp was -3.9 [-4.5- -3.0] cmH2O, with range -7.9 - -1.9 cmH2O. Per-patient E and R were 16.4 [13.6-21.8] cmH2O/L and 9.2 [6.4-13.1] cmH2O.s/L, respectively. Most patients showed an inspiratory volume threshold beyond which Pp started to return to baseline, and Pp at peak Eadi (end-inspiration) was often strongly correlated with peak Eadi (R2=0.25-0.86). Similarly, average transpulmonary pressure was consistent breath-breath in most patients, despite differences in peak Eadi and thus peak airway pressure. CONCLUSIONS The model-based inspiratory effort aligns with electrical muscle activity and published studies showing neuro-muscular decoupling as a function of pressure and/or volume. Consistency in coupling/dynamics were patient-specific. Quantification of patient and ventilator work of breathing contributions may aid optimisation of MV modes and weaning.
Collapse
Affiliation(s)
- Jennifer L Knopp
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand.
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Kyeong Tae Kim
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Geoffrey M Shaw
- Department of Intensive Care, Christchurch Hospital, Private Bag 4710, Christchurch, New Zealand
| |
Collapse
|
9
|
Abstract
BACKGROUND Stress-induced hyperglycemia is frequently experienced by critically ill patients and the use of glycemic control (GC) has been shown to improve patient outcomes. For model-based approaches to GC, it is important to understand and quantify model parameter assumptions. This study explores endogenous glucose production (EGP) and the use of a population-based parameter value in the intensive care unit context. METHOD Hourly insulin sensitivity (SI) was fit to clinical data from 145 patients on the Specialized Relative Insulin and Nutrition Titration GC protocol for at least 24 hours. Constraint of SI at a lower bound was used to explore likely EGP variability due to stress response. Minimum EGP was estimated during times when the model SI was constrained, and time and duration of events were examined. RESULTS Constrained events occur for 1.6% of patient hours. About 70% of constrained events occur in the first 12 hours and most events (~80%) occur when there is no exogenous nutrition given. Enhanced EGP values ranged from 1.16 mmol/min (current population value) to 2.75 mmol/min, with most being below 1.5 mmol/min (21% increase). CONCLUSION The frequency of constrained events is low and the current population value of 1.16 mmol/min is sufficient for more than 98% of patient hours, however, some patients experience significantly raised EGP probably due to an extreme stress response early in patient stay.
Collapse
Affiliation(s)
- Jennifer J. Ormsbee
- Department of Mechanical Engineering, Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - Jennifer L. Knopp
- Department of Mechanical Engineering, Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - J. Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
10
|
Zhou C, Chase JG, Knopp J, Sun Q, Tawhai M, Möller K, Heines SJ, Bergmans DC, Shaw GM, Desaive T. Virtual patients for mechanical ventilation in the intensive care unit. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 199:105912. [PMID: 33360683 DOI: 10.1016/j.cmpb.2020.105912] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 12/12/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND Mechanical ventilation (MV) is a core intensive care unit (ICU) therapy. Significant inter- and intra- patient variability in lung mechanics and condition makes managing MV difficult. Accurate prediction of patient-specific response to changes in MV settings would enable optimised, personalised, and more productive care, improving outcomes and reducing cost. This study develops a generalised digital clone model, or in-silico virtual patient, to accurately predict lung mechanics in response to changes in MV. METHODS An identifiable, nonlinear hysteresis loop model (HLM) captures patient-specific lung dynamics identified from measured ventilator data. Identification and creation of the virtual patient model is fully automated using the hysteresis loop analysis (HLA) method to identify lung elastances from clinical data. Performance is evaluated using clinical data from 18 volume-control (VC) and 14 pressure-control (PC) ventilated patients who underwent step-wise recruitment maneuvers. RESULTS Patient-specific virtual patient models accurately predict lung response for changes in PEEP up to 12 cmH2O for both volume and pressure control cohorts. R2 values for predicting peak inspiration pressure (PIP) and additional retained lung volume, Vfrc in VC, are R2=0.86 and R2=0.90 for 106 predictions over 18 patients. For 14 PC patients and 84 predictions, predicting peak inspiratory volume (PIV) and Vfrc yield R2=0.86 and R2=0.83. Absolute PIP, PIV and Vfrc errors are relatively small. CONCLUSIONS Overall results validate the accuracy and versatility of the virtual patient model for capturing and predicting nonlinear changes in patient-specific lung mechanics. Accurate response prediction enables mechanically and physiologically relevant virtual patients to guide personalised and optimised MV therapy.
Collapse
Affiliation(s)
- Cong Zhou
- School of Civil Aviation, Northwestern Polytechnical University, China; Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, New Zealand.
| | - Jennifer Knopp
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - Qianhui Sun
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - Merryn Tawhai
- Auckland Bio-Engineering Institute (ABI), University of Auckland, New Zealand
| | - Knut Möller
- Institute for Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Serge J Heines
- Department of Intensive Care, School of Medicine, Maastricht University, Maastricht, the Netherlands
| | - Dennis C Bergmans
- Department of Intensive Care, School of Medicine, Maastricht University, Maastricht, the Netherlands
| | - Geoffrey M Shaw
- Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand
| | - Thomas Desaive
- GIGA-In Silico Medicine, Institute of Physics, University of Liege, Liege, Belgium
| |
Collapse
|
11
|
Lee JWW, Chiew YS, Wang X, Tan CP, Mat Nor MB, Damanhuri NS, Chase JG. Stochastic Modelling of Respiratory System Elastance for Mechanically Ventilated Respiratory Failure Patients. Ann Biomed Eng 2021; 49:3280-3295. [PMID: 34435276 PMCID: PMC8386681 DOI: 10.1007/s10439-021-02854-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 08/13/2021] [Indexed: 02/07/2023]
Abstract
While lung protective mechanical ventilation (MV) guidelines have been developed to avoid ventilator-induced lung injury (VILI), a one-size-fits-all approach cannot benefit every individual patient. Hence, there is significant need for the ability to provide patient-specific MV settings to ensure safety, and optimise patient care. Model-based approaches enable patient-specific care by identifying time-varying patient-specific parameters, such as respiratory elastance, Ers, to capture inter- and intra-patient variability. However, patient-specific parameters evolve with time, as a function of disease progression and patient condition, making predicting their future values crucial for recommending patient-specific MV settings. This study employs stochastic modelling to predict future Ers values using retrospective patient data to develop and validate a model indicating future intra-patient variability of Ers. Cross validation results show stochastic modelling can predict future elastance ranges with 92.59 and 68.56% of predicted values within the 5-95% and the 25-75% range, respectively. This range can be used to ensure patients receive adequate minute ventilation should elastance rise and minimise the risk of VILI should elastance fall. The results show the potential for model-based protocols using stochastic model prediction of future Ers values to provide safe and patient-specific MV. These results warrant further investigation to validate its clinical utility.
Collapse
Affiliation(s)
- Jay Wing Wai Lee
- grid.440425.3School of Engineering, Monash University Malaysia, 47500 Subang Jaya, Selangor Malaysia
| | - Yeong Shiong Chiew
- grid.440425.3School of Engineering, Monash University Malaysia, 47500 Subang Jaya, Selangor Malaysia
| | - Xin Wang
- grid.440425.3School of Engineering, Monash University Malaysia, 47500 Subang Jaya, Selangor Malaysia
| | - Chee Pin Tan
- grid.440425.3School of Engineering, Monash University Malaysia, 47500 Subang Jaya, Selangor Malaysia
| | - Mohd Basri Mat Nor
- grid.440422.40000 0001 0807 5654Kulliyah of Medicine, International Islamic University Malaysia, 25200 Kuantan, Pahang Malaysia
| | - Nor Salwa Damanhuri
- grid.412259.90000 0001 2161 1343Faculty of Electrical Engineering, Universiti Teknologi MARA, Cawangan Pulau Pinang, 13500 Bukit Bertajam, Pulau Pinang Malaysia
| | - J. Geoffrey Chase
- grid.21006.350000 0001 2179 4063Center of Bioengineering, University of Canterbury, Christchurch, 8041 New Zealand
| |
Collapse
|
12
|
Knopp JL, Bishop K, Lerios T, Chase JG. Capacity of Infusion Lines for Insulin Adsorption: Effect of Flow Rate on Total Adsorption. J Diabetes Sci Technol 2021; 15:109-120. [PMID: 31561709 PMCID: PMC7783010 DOI: 10.1177/1932296819876924] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
BACKGROUND Insulin adsorption to clinical materials has been well observed, but not well quantified. Insulin adsorption reduces expected and actual insulin delivery and is unaccounted for in insulin therapy or glycemic control. It may thus contribute to poor control and high glycemic variability. This research quantifies the problem in the context of clinical use. METHOD Experimental insulin adsorption data from literature is used to calculate insulin delivery and total insulin adsorption capacities for polyethylene (PE) and polyvinal chloride (PVC) lines at clinically relevant flow rates and concentrations. RESULTS Insulin adsorption capacity decreased hyperbolically with flow rate for both PE and PVC, where low flow scenarios result in greater insulin adherence to infusion lines. When the infusion flow rate was halved from 1 to 0.5 mL/h, twice as much insulin adsorbed to the line. Insulin loss to adsorption resulted in up to ~50% of intended insulin not delivered over 24 hours in a low flow and low concentration context. CONCLUSION Material capacity for insulin adsorption is not constant, but increases with decreasing flow. Different materials have different adsorption capacities. In low flow and low concentration contexts, such as in neonatal or pediatric intensive care, insulin loss to adsorption represents a significant proportion of daily insulin delivery, which needs to be accounted for.
Collapse
Affiliation(s)
- Jennifer L. Knopp
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
- Jennifer L. Knopp, PhD, Department of Mechanical Engineering, University of Canterbury, 20 Kirkwood Ave, Riccarton, Christchurch 8041, New Zealand.
| | - Kaia Bishop
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Theodore Lerios
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - J. Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
13
|
Howe SL, März M, Krüger-Ziolek S, Laufer B, Pretty C, Shaw GM, Desaive T, Möller K, Chase JG. Measuring lung mechanics of expiratory tidal breathing with non-invasive breath occlusion. Biomed Eng Online 2020; 19:32. [PMID: 32410675 PMCID: PMC7224083 DOI: 10.1186/s12938-020-00777-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 04/30/2020] [Indexed: 11/19/2022] Open
Abstract
Background and objective Lung mechanics measurements provide clinically useful information about disease progression and lung health. Currently, there are no commonly practiced methods to non-invasively measure both resistive and elastic lung mechanics during tidal breathing, preventing the important information provided by lung mechanics from being utilised. This study presents a novel method to easily assess lung mechanics of spontaneously breathing subjects using a dynamic elastance, single-compartment lung model. Methods A spirometer with a built-in shutter was used to occlude expiration during tidal breathing, creating exponentially decaying flow when the shutter re-opened. The lung mechanics measured were respiratory system elastance and resistance, separated from the exponentially decaying flow, and interrupter resistance calculated at shutter closure. Progressively increasing resistance was added to the spirometer mouthpiece to simulate upper airway obstruction. The lung mechanics of 17 healthy subjects were successfully measured through spirometry. Results N = 17 (8 female, 9 male) healthy subjects were recruited. Measured decay rates ranged from 5 to 42/s, subjects with large variation of decay rates showed higher muscular breathing effort. Lung elastance measurements ranged from 3.9 to 21.2 cmH\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$_2$$\end{document}2O/L, with no clear trend between change in elastance and added resistance. Resistance calculated from decay rate and elastance ranged from 0.15 to 1.95 cmH\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$_2$$\end{document}2Os/L. These very small resistance values are due to the airflow measured originating from low-resistance areas in the centre of airways. Occlusion resistance measurements were as expected for healthy subjects, and increased as expected as resistance was added. Conclusions This test was able to identify reasonable dynamic lung elastance and occlusion resistance values, providing new insight into expiratory breathing effort. Clinically, this lung function test could impact current practice. It does not require high levels of cooperation from the subject, allowing a wider cohort of patients to be assessed more easily. Additionally, this test can be simply implemented in a small standalone device, or with standard lung function testing equipment.
Collapse
Affiliation(s)
- Sarah L Howe
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Melanie März
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| | - Sabine Krüger-Ziolek
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| | - Bernhard Laufer
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| | - Chris Pretty
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Geoffery M Shaw
- Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand
| | - Thomas Desaive
- GIGA Cardiovascular Science, University of Liege, Liege, Belgium
| | - Knut Möller
- Institute of Technical Medicine (ITeM), Furtwangen University, Villingen-Schwenningen, Germany
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
| |
Collapse
|
14
|
Kim KT, Knopp J, Dixon B, Chase JG. Mechanically ventilated premature babies have sex differences in specific elastance: A pilot study. Pediatr Pulmonol 2020; 55:177-184. [PMID: 31596060 DOI: 10.1002/ppul.24538] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 09/18/2019] [Indexed: 11/09/2022]
Abstract
OBJECTIVES A pilot study to compare pulmonary mechanics in a neonatal intensive care unit (NICU) cohort, specifically, comparing lung elastance between male and female infants in the NICU. HYPOTHESIS Anecdotally, male infants are harder to ventilate than females. We hypothesize that males have higher model-based elastance (converse: lower specific compliance) compared to females, reflecting underlying stiffer lungs. STUDY DESIGN A clinically validated, single-compartment model is used to identify specific elastance (inverse of specific compliance) and resistance for each breath. Specific elastance accounts for weight differences when comparing male and female infants. Relative percent breath-to-breath variability (%ΔE) in specific elastance is also compared. Level of asynchrony was also determined. PATIENT-SUBJECT SELECTION Ten invasively mechanically ventilated patients from Christchurch Women's Hospital. METHODOLOGY Airway pressure and flow data from 10 invasive mechanical ventilation (MV) infants from Christchurch Women's Hospital Neonatal Intensive Care Unit, New Zealand was prospectively recorded under standard MV care. Model-based specific elastance and resistance are identified for each breath, as well as relative percent breath-to-breath variability (%ΔE) in specific elastance. RESULTS Male infants overall had higher specific elastance compared to females infants (P ≤ .01), with median (interquartile range) for males of 1.91 (1.33-2.48) cmH2 O·kg/mL compared to 1.31 (0.86-2.02) cmH2 O·kg/mL in females. Male infants had lower variability with %ΔE of -0.03 (-7.56 to 8.01)% vs female infants of -0.59 (12.56-12.86)%. Males had 14.75% asynchronous breaths whereas females had 17.54%. CONCLUSION Overall, males had higher specific elastance and correspondingly lower breath-to-breath variability. These results indicate male and female infants may require different MV settings, mode, and monitoring.
Collapse
Affiliation(s)
- Kyeong Tae Kim
- Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - Jennifer Knopp
- Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - Bronwyn Dixon
- Neonatal Intensive Care Unit, Christchurch Women's Hospital, Christchurch, New Zealand
| | - J Geoffrey Chase
- Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
15
|
Yahia A, Benyo B, Chase JG. Clinical application scenarios to handle insulin resistance and high endogenous glucose production for intensive care patients. ACTA ACUST UNITED AC 2020. [DOI: 10.1016/j.ifacol.2020.12.650] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
16
|
Davidson S, Pretty C, Uyttendaele V, Knopp J, Desaive T, Chase JG. Multi-input stochastic prediction of insulin sensitivity for tight glycaemic control using insulin sensitivity and blood glucose data. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 182:105043. [PMID: 31470221 DOI: 10.1016/j.cmpb.2019.105043] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Revised: 07/28/2019] [Accepted: 08/20/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND Glycaemic control in the intensive care unit is dependent on effective prediction of patient insulin sensitivity (SI). The stochastic targeted (STAR) controller uses a 2D stochastic model for prediction, with current SI as an input and future SI as an output. METHODS This paper develops an extension of the STAR 2D stochastic model into 3D by adding blood glucose (G) as an input. The performance of the 2D and 3D stochastic models is compared over a retrospective cohort of 65,269 data points across 1525 patients. RESULTS Under five-fold cross-validation, the 3D model was found to better match the expected potion of data points within, above and below various credible intervals, suggesting it provided a better representation of the underlying probability field. The 3D model was also found to provide an 18.1% narrower 90% credible interval on average, and a narrower 90% credible interval in 96.4% of cases, suggesting it provided more accurate predictions of future SI. Additionally, the 3D stochastic model was found to avoid the undesirable tendency of the 2D model to overestimate SI for patients with high G, and underestimate SI for patients with low G. CONCLUSIONS Overall, the 3D stochastic model is shown to provide clear potential benefits over the 2D model for minimal clinical cost or effort, though further exploration into whether these improvements in SI prediction translate into improved clinical outcomes is required.
Collapse
Affiliation(s)
- Shaun Davidson
- Department of Mechanical Engineering, University of Canterbury, 20 Kirkwood Ave, Upper Riccarton, Christchurch 8041, New Zealand.
| | - Chris Pretty
- Department of Mechanical Engineering, University of Canterbury, 20 Kirkwood Ave, Upper Riccarton, Christchurch 8041, New Zealand
| | | | - Jennifer Knopp
- Department of Mechanical Engineering, University of Canterbury, 20 Kirkwood Ave, Upper Riccarton, Christchurch 8041, New Zealand
| | - Thomas Desaive
- GIGA-Cardiovascular Sciences, University of Liège, Liège, Belgium
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, 20 Kirkwood Ave, Upper Riccarton, Christchurch 8041, New Zealand
| |
Collapse
|
17
|
van Noorden B, Knopp JL, Chase JG. A subcutaneous insulin pharmacokinetic model for insulin Detemir. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 178:1-9. [PMID: 31416537 DOI: 10.1016/j.cmpb.2019.06.007] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 05/16/2019] [Accepted: 06/07/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE Type 2 diabetes (T2D) is rapidly increasing in incidence and has significant social and economic costs. Given the increasing cost of complications, even relatively short delays in the onset of T2D can significantly reduce long-term complications and costs. Equally, recent studies have shown the onset of T2D can be delayed by use of long-acting insulin, despite the risk and concomitant low adherence. Thus, there is a strong potential motivation to develop models of long-acting insulin analogues to enable safe, effective use in model-based dosing systems. In particular, there are no current models of long-acting insulin Detemir and its unique action for model-based control. The objective of this work is to develop a first model of insulin Detemir and its unique action, and validate it against existing data in the literature. METHODS This study develops a detailed compartment model for insulin Detemir. Model specific parameters are identified using data from a range of published clinical studies on the pharmacokinetic of insulin Detemir. Model validity and robustness are assessed by identifying the model for each study and using average identified parameters over several dose sizes and study cohorts. Comparisons to peak concentration, time of peak concentration and overall error versus measured plasma concentrations are used to assess model accuracy and validity. RESULTS Almost all studies and cohorts fit literature data to within one standard deviation of error, even when using averaged identified model parameters. However, there appears to be a noticeable dose dependent dynamic not included in this first model, nor reported in the literature studies. CONCLUSIONS A first model of insulin Detemir including its unique albumin binding kinetics is derived and provisionally validated against clinical pharmacokinetic data. The pharmacokinetic curves are suitable for model-based control and general enough for use. While there are limitations in the studies used for validation that prevent a more complete understanding, the results provide an effective first model and justify the design and implementation of further, more precise human trials.
Collapse
Affiliation(s)
- Ben van Noorden
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand
| | - Jennifer L Knopp
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand.
| |
Collapse
|
18
|
Kim KT, Knopp J, Dixon B, Chase G. Quantifying neonatal pulmonary mechanics in mechanical ventilation. Biomed Signal Process Control 2019. [DOI: 10.1016/j.bspc.2019.04.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
19
|
Abu-Samah A, Knopp JL, Abdul Razak NN, Razak AA, Jamaludin UK, Mohamad Suhaimi F, Md Ralib A, Mat Nor MB, Chase JG, Pretty CG. Model-based glycemic control in a Malaysian intensive care unit: performance and safety study. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2019; 12:215-226. [PMID: 31239792 PMCID: PMC6551612 DOI: 10.2147/mder.s187840] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Accepted: 01/30/2019] [Indexed: 01/08/2023] Open
Abstract
Background: Stress-induced hyperglycemia is common in critically ill patients. A few forms of model-based glycemic control have been introduced to reduce this phenomena and among them is the automated STAR protocol which has been used in the Christchurch and Gyulá hospitals' intensive care units (ICUs) since 2010. Methods: This article presents the pilot trial assessment of STAR protocol which has been implemented in the International Islamic University Malaysia Medical Centre (IIUMMC) Hospital ICU since December 2017. One hundred and forty-two patients who received STAR treatment for more than 20 hours were used in the assessment. The initial results are presented to discuss the ability to adopt and adapt the model-based control framework in a Malaysian environment by analyzing its performance and safety. Results: Overall, 60.7% of blood glucose measurements were in the target band. Only 0.78% and 0.02% of cohort measurements were below 4.0 mmol/L and 2.2 mmol/L (the limitsfor mild and severe hypoglycemia, respectively). Treatment preference-wise, the clinical staff were favorable of longer intervention options when available. However, 1 hourly treatments were still used in 73.7% of cases. Conclusion: The protocol succeeded in achieving patient-specific glycemic control while maintaining safety and was trusted by nurses to reduce workload. Its lower performance results, however, give the indication for modification in some of the control settings to better fit the Malaysian environment.
Collapse
Affiliation(s)
- Asma Abu-Samah
- Institute of Energy Infrastructure, Universiti Tenaga Nasional, Kajang, 43000, Malaysia
| | - Jennifer Launa Knopp
- Department of Mechanical Engineering, University of Canterbury, Christchurch, 8041, New Zealand
| | | | | | | | | | - Azrina Md Ralib
- Advanced Medical and Dental Institute, Universiti Sains Islam Malaysia, Kepala Batas, 13200, Malaysia
| | - Mohd Basri Mat Nor
- Kulliyah of Medicine, International Islamic University Malaysia, Kuantan, 25200, Malaysia
| | - James Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, 8041, New Zealand
| | | |
Collapse
|
20
|
de Bournonville S, Pironet A, Pretty C, Chase JG, Desaive T. Parameter estimation in a minimal model of cardio-pulmonary interactions. Math Biosci 2019; 313:81-94. [PMID: 31128126 DOI: 10.1016/j.mbs.2019.05.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 05/21/2019] [Accepted: 05/22/2019] [Indexed: 11/25/2022]
Abstract
Mechanical ventilation is a widely used breathing support for patients in intensive care. Its effects on the respiratory and cardiovascular systems are complex and difficult to predict. This work first presents a minimal mathematical model representing the mechanics of both systems and their interaction, in terms of flows, pressures and volumes. The aim of this model is to get insight on the two systems' status when mechanical ventilation settings, such as positive end-expiratory pressure, are changing. The parameters of the model represent cardiac elastances and vessel compliances and resistances. As a second step, these parameters are estimated from 16 experimental datasets. The data come from three pig experiments reproducing intensive care conditions, where a large range of positive end-expiratory pressures was imposed by the mechanical ventilator. The data used for parameter estimation is limited to information available in the intensive care unit, such as stroke volume, central venous pressure and systemic arterial pressure. The model is able to satisfactorily reproduce this experimental data, with mean relative errors ranging from 1 to 26%. The model also reproduces the dynamics of the cardio-vascular and respiratory systems, and their interaction. By looking at the estimated parameter values, one can quantitatively track how the two coupled systems mechanically react to changes in external conditions imposed by the ventilator. This work thus allows real-time, model-based management of ventilator settings.
Collapse
Affiliation(s)
- Sébastien de Bournonville
- Prometheus, Division of Skeletal Tissue Engineering, Katholieke Universiteit Leuven (KUL), Leuven, Belgium; GIGA-In Silico Medicine, University of Liège (ULg), Liège, Belgium.
| | - Antoine Pironet
- GIGA-In Silico Medicine, University of Liège (ULg), Liège, Belgium.
| | - Chris Pretty
- University of Canterbury, Department of Mechanical Engineering, Christchurch, New Zealand.
| | - J Geoffrey Chase
- University of Canterbury, Department of Mechanical Engineering, Christchurch, New Zealand.
| | - Thomas Desaive
- GIGA-In Silico Medicine, University of Liège (ULg), Liège, Belgium.
| |
Collapse
|
21
|
Morton SE, Knopp JL, Chase JG, Docherty P, Howe SL, Möller K, Shaw GM, Tawhai M. Optimising mechanical ventilation through model-based methods and automation. ANNUAL REVIEWS IN CONTROL 2019; 48:369-382. [PMID: 36911536 PMCID: PMC9985488 DOI: 10.1016/j.arcontrol.2019.05.001] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Revised: 04/09/2019] [Accepted: 05/01/2019] [Indexed: 06/11/2023]
Abstract
Mechanical ventilation (MV) is a core life-support therapy for patients suffering from respiratory failure or acute respiratory distress syndrome (ARDS). Respiratory failure is a secondary outcome of a range of injuries and diseases, and results in almost half of all intensive care unit (ICU) patients receiving some form of MV. Funding the increasing demand for ICU is a major issue and MV, in particular, can double the cost per day due to significant patient variability, over-sedation, and the large amount of clinician time required for patient management. Reducing cost in this area requires both a decrease in the average duration of MV by improving care, and a reduction in clinical workload. Both could be achieved by safely automating all or part of MV care via model-based dynamic systems modelling and control methods are ideally suited to address these problems. This paper presents common lung models, and provides a vision for a more automated future and explores predictive capacity of some current models. This vision includes the use of model-based methods to gain real-time insight to patient condition, improve safety through the forward prediction of outcomes to changes in MV, and develop virtual patients for in-silico design and testing of clinical protocols. Finally, the use of dynamic systems models and system identification to guide therapy for improved personalised control of oxygenation and MV therapy in the ICU will be considered. Such methods are a major part of the future of medicine, which includes greater personalisation and predictive capacity to both optimise care and reduce costs. This review thus presents the state of the art in how dynamic systems and control methods can be applied to transform this core area of ICU medicine.
Collapse
Affiliation(s)
- Sophie E Morton
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - Jennifer L Knopp
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - Paul Docherty
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - Sarah L Howe
- Department of Mechanical Engineering, University of Canterbury, New Zealand
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Geoffrey M Shaw
- Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand
| | - Merryn Tawhai
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| |
Collapse
|
22
|
Pironet A, Docherty PD, Dauby PC, Chase JG, Desaive T. Practical identifiability analysis of a minimal cardiovascular system model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 171:53-65. [PMID: 28153466 DOI: 10.1016/j.cmpb.2017.01.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Revised: 12/01/2016] [Accepted: 01/16/2017] [Indexed: 06/06/2023]
Abstract
BACKGROUND AND OBJECTIVE Parameters of mathematical models of the cardiovascular system can be used to monitor cardiovascular state, such as total stressed blood volume status, vessel elastance and resistance. To do so, the model parameters have to be estimated from data collected at the patient's bedside. This work considers a seven-parameter model of the cardiovascular system and investigates whether these parameters can be uniquely determined using indices derived from measurements of arterial and venous pressures, and stroke volume. METHODS An error vector defined the residuals between the simulated and reference values of the seven clinically available haemodynamic indices. The sensitivity of this error vector to each model parameter was analysed, as well as the collinearity between parameters. To assess practical identifiability of the model parameters, profile-likelihood curves were constructed for each parameter. RESULTS Four of the seven model parameters were found to be practically identifiable from the selected data. The remaining three parameters were practically non-identifiable. Among these non-identifiable parameters, one could be decreased as much as possible. The other two non-identifiable parameters were inversely correlated, which prevented their precise estimation. CONCLUSIONS This work presented the practical identifiability analysis of a seven-parameter cardiovascular system model, from limited clinical data. The analysis showed that three of the seven parameters were practically non-identifiable, thus limiting the use of the model as a monitoring tool. Slight changes in the time-varying function modeling cardiac contraction and use of larger values for the reference range of venous pressure made the model fully practically identifiable.
Collapse
Affiliation(s)
- Antoine Pironet
- GIGA-In Silico Medicine, University of Liège, B5a, Quartier Agora, Allée du 6 août, 19, 4000 Liège, Belgium.
| | - Paul D Docherty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Pierre C Dauby
- GIGA-In Silico Medicine, University of Liège, B5a, Quartier Agora, Allée du 6 août, 19, 4000 Liège, Belgium
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand
| | - Thomas Desaive
- GIGA-In Silico Medicine, University of Liège, B5a, Quartier Agora, Allée du 6 août, 19, 4000 Liège, Belgium
| |
Collapse
|
23
|
Knopp JL, Signal M, Harris DL, Marics G, Weston P, Harding J, Tóth-Heyn P, Hómlok J, Benyó B, Chase JG. Modelling intestinal glucose absorption in premature infants using continuous glucose monitoring data. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 171:41-51. [PMID: 30344050 DOI: 10.1016/j.cmpb.2018.10.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Revised: 09/11/2018] [Accepted: 10/01/2018] [Indexed: 06/08/2023]
Abstract
BACKGROUND Model-based glycaemic control protocols have shown promise in neonatal intensive care units (NICUs) for reducing both hyperglycaemia and insulin-therapy driven hypoglycaemia. However, current models for the appearance of glucose from enteral feeding are based on values from adult intensive care cohorts. This study aims to determine enteral glucose appearance model parameters more reflective of premature infant physiology. METHODS Peaks in CGM data associated with enteral milk feeds in preterm and term infants are used to fit a two compartment gut model. The first compartment describes glucose in the stomach, and the half life of gastric emptying is estimated as 20 min from literature. The second compartment describes glucose in the small intestine, and absorption of glucose into the blood is fit to CGM data. Two infant cohorts from two NICUs are used, and results are compared to appearances derived from data in highly controlled studies in literature. RESULTS The average half life across all infants for glucose absorption from the gut to the blood was 50 min. This result was slightly slower than, but of similar magnitude to, results derived from literature. No trends were found with gestational or postnatal age. Breast milk fed infants were found to have a higher absorption constant than formula fed infants, a result which may reflect known differences in gastric emptying for different feed types. CONCLUSIONS This paper presents a methodology for estimation of glucose appearance due to enteral feeding, and model parameters suitable for a NICU model-based glycaemic control context.
Collapse
Affiliation(s)
- J L Knopp
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
| | - M Signal
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
| | - D L Harris
- Newborn Intensive Care Unit, Waikato District Health Board, Hamilton, New Zealand; Liggins Institute, University of Auckland, Auckland, New Zealand.
| | - G Marics
- First Department of Paediatrics, Intensive Care Unit, Semmelweis University, Budapest, Hungary
| | - P Weston
- Newborn Intensive Care Unit, Waikato District Health Board, Hamilton, New Zealand.
| | - J Harding
- Liggins Institute, University of Auckland, Auckland, New Zealand.
| | - P Tóth-Heyn
- First Department of Paediatrics, Intensive Care Unit, Semmelweis University, Budapest, Hungary.
| | - J Hómlok
- Budapest University of Technology and Economics, Budapest, Hungary
| | - B Benyó
- Budapest University of Technology and Economics, Budapest, Hungary.
| | - J G Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
| |
Collapse
|
24
|
Predictive Virtual Patient Modelling of Mechanical Ventilation: Impact of Recruitment Function. Ann Biomed Eng 2019; 47:1626-1641. [PMID: 30927170 DOI: 10.1007/s10439-019-02253-w] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 03/22/2019] [Indexed: 10/27/2022]
Abstract
Mechanical ventilation is a life-support therapy for intensive care patients suffering from respiratory failure. To reduce the current rate of ventilator-induced lung injury requires ventilator settings that are patient-, time-, and disease-specific. A common lung protective strategy is to optimise the level of positive end-expiratory pressure (PEEP) through a recruitment manoeuvre to prevent alveolar collapse at the end of expiration and to improve gas exchange through recruitment of additional alveoli. However, this process can subject parts of the lung to excessively high pressures or volumes. This research significantly extends and more robustly validates a previously developed pulmonary mechanics model to predict lung mechanics throughout recruitment manoeuvres. In particular, the process of recruitment is more thoroughly investigated and the impact of the inclusion of expiratory data when estimating peak inspiratory pressure is assessed. Data from the McREM trial and CURE pilot trial were used to test model predictive capability and assumptions. For PEEP changes of up to and including 14 cmH2O, the parabolic model was shown to improve peak inspiratory pressure prediction resulting in less than 10% absolute error in the CURE cohort and 16% in the McREM cohort. The parabolic model also better captured expiratory mechanics than the exponential model for both cohorts.
Collapse
|
25
|
Joubert D, Stigter JD, Molenaar J. Determining minimal output sets that ensure structural identifiability. PLoS One 2018; 13:e0207334. [PMID: 30419074 PMCID: PMC6231658 DOI: 10.1371/journal.pone.0207334] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 10/30/2018] [Indexed: 01/29/2023] Open
Abstract
The process of inferring parameter values from experimental data can be a cumbersome task. In addition, the collection of experimental data can be time consuming and costly. This paper covers both these issues by addressing the following question: “Which experimental outputs should be measured to ensure that unique model parameters can be calculated?”. Stated formally, we examine the topic of minimal output sets that guarantee a model’s structural identifiability. To that end, we introduce an algorithm that guides a researcher as to which model outputs to measure. Our algorithm consists of an iterative structural identifiability analysis and can determine multiple minimal output sets of a model. This choice in different output sets offers researchers flexibility during experimental design. Our method can determine minimal output sets of large differential equation models within short computational times.
Collapse
Affiliation(s)
- D. Joubert
- Wageningen University and Research, Biometris, Department of Mathematical and Statistical Methods, Wageningen, The Netherlands
- * E-mail:
| | - J. D. Stigter
- Wageningen University and Research, Biometris, Department of Mathematical and Statistical Methods, Wageningen, The Netherlands
| | - J. Molenaar
- Wageningen University and Research, Biometris, Department of Mathematical and Statistical Methods, Wageningen, The Netherlands
| |
Collapse
|
26
|
Uyttendaele V, Knopp JL, Stewart KW, Desaive T, Benyó B, Szabó-Némedi N, Illyés A, Shaw GM, Chase JG. A 3D insulin sensitivity prediction model enables more patient-specific prediction and model-based glycaemic control. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2018.05.032] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
27
|
Garcia-Tirado J, Zuluaga-Bedoya C, Breton MD. Identifiability Analysis of Three Control-Oriented Models for Use in Artificial Pancreas Systems. J Diabetes Sci Technol 2018; 12:937-952. [PMID: 30095007 PMCID: PMC6134618 DOI: 10.1177/1932296818788873] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
OBJECTIVE Our aim is to analyze the identifiability of three commonly used control-oriented models for glucose control in patients with type 1 diabetes (T1D). METHODS Structural and practical identifiability analysis were performed on three published control-oriented models for glucose control in patients with type 1 diabetes (T1D): the subcutaneous oral glucose minimal model (SOGMM), the intensive control insulin-nutrition-glucose (ICING) model, and the minimal model control-oriented (MMC). Structural identifiability was addressed with a combination of the generating series (GS) approach and identifiability tableaus whereas practical identifiability was studied by means of (1) global ranking of parameters via sensitivity analysis together with the Latin hypercube sampling method (LHS) and (2) collinearity analysis among parameters. For practical identifiability and model identification, continuous glucose monitor (CGM), insulin pump, and meal records were selected from a set of patients (n = 5) on continuous subcutaneous insulin infusion (CSII) that underwent a clinical trial in an outpatient setting. The performance of the identified models was analyzed by means of the root mean square (RMS) criterion. RESULTS A reliable set of identifiable parameters was found for every studied model after analyzing the possible identifiability issues of the original parameter sets. According to an importance factor ([Formula: see text]), it was shown that insulin sensitivity is not the most influential parameter from the dynamical point of view, that is, is not the parameter impacting the outputs the most of the three models, contrary to what is assumed in the literature. For the test data, the models demonstrated similar performance with most RMS values around 20 mg/dl (min: 15.64 mg/dl, max: 51.32 mg/dl). However, MMC failed to identify the model for patient 4. Also, considering the three models, the MMC model showed the higher parameter variability when reidentified every 6 hours. CONCLUSION This study shows that both structural and practical identifiability analysis need to be considered prior to the model identification/individualization in patients with T1D. It was shown that all the studied models are able to represent the CGM data, yet their usefulness in a hypothetical artificial pancreas could be a matter of debate. In spite that the three models do not capture all the dynamics and metabolic effects as a maximal model (ie, our FDA-accepted UVa/Padova simulator), SOGMM and ICING appear to be more appealing than MMC regarding both the performance and parameter variability after reidentification. Although the model predictions of ICING are comparable to the ones of the SOGMM model, the large parameter set makes the model prone to overfitting if all parameters are identified. Moreover, the existence of a high nonlinear function like [Formula: see text] prevents the use of tools from the linear systems theory.
Collapse
Affiliation(s)
- Jose Garcia-Tirado
- Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
| | - Christian Zuluaga-Bedoya
- Dynamic Processes Research Group KALMAN, Universidad Nacional de Colombia, Medellín, Antioquia, Colombia
| | - Marc D. Breton
- Center for Diabetes Technology, University of Virginia, Charlottesville, VA, USA
| |
Collapse
|
28
|
Stewart KW, Pretty CG, Shaw GM, Chase JG. Creating smooth SI. B-spline basis function representations of insulin sensitivity. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2018.05.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
29
|
Chiew YS, Tan CP, Chase JG, Chiew YW, Desaive T, Ralib AM, Mat Nor MB. Assessing mechanical ventilation asynchrony through iterative airway pressure reconstruction. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 157:217-224. [PMID: 29477430 DOI: 10.1016/j.cmpb.2018.02.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2017] [Revised: 01/05/2018] [Accepted: 02/02/2018] [Indexed: 06/08/2023]
Abstract
BACKGROUND AND OBJECTIVE Respiratory mechanics estimation can be used to guide mechanical ventilation (MV) but is severely compromised when asynchronous breathing occurs. In addition, asynchrony during MV is often not monitored and little is known about the impact or magnitude of asynchronous breathing towards recovery. Thus, it is important to monitor and quantify asynchronous breathing over every breath in an automated fashion, enabling the ability to overcome the limitations of model-based respiratory mechanics estimation during asynchronous breathing ventilation. METHODS An iterative airway pressure reconstruction (IPR) method is used to reconstruct asynchronous airway pressure waveforms to better match passive breathing airway waveforms using a single compartment model. The reconstructed pressure enables estimation of respiratory mechanics of airway pressure waveform essentially free from asynchrony. Reconstruction enables real-time breath-to-breath monitoring and quantification of the magnitude of the asynchrony (MAsyn). RESULTS AND DISCUSSION Over 100,000 breathing cycles from MV patients with known asynchronous breathing were analyzed. The IPR was able to reconstruct different types of asynchronous breathing. The resulting respiratory mechanics estimated using pressure reconstruction were more consistent with smaller interquartile range (IQR) compared to respiratory mechanics estimated using asynchronous pressure. Comparing reconstructed pressure with asynchronous pressure waveforms quantifies the magnitude of asynchronous breathing, which has a median value MAsyn for the entire dataset of 3.8%. CONCLUSION The iterative pressure reconstruction method is capable of identifying asynchronous breaths and improving respiratory mechanics estimation consistency compared to conventional model-based methods. It provides an opportunity to automate real-time quantification of asynchronous breathing frequency and magnitude that was previously limited to invasively method only.
Collapse
Affiliation(s)
| | - Chee Pin Tan
- School of Engineering, Monash University, Subang Jaya, Malaysia.
| | - J Geoffrey Chase
- Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand.
| | | | - Thomas Desaive
- GIGA Cardiovascular Science, University of Liege, Liege, Belgium.
| | - Azrina Md Ralib
- Department of Intensive Care, International Islamic University Malaysia Medical Centre, Kuantan, Malaysia.
| | - Mohd Basri Mat Nor
- Department of Intensive Care, International Islamic University Malaysia Medical Centre, Kuantan, Malaysia.
| |
Collapse
|
30
|
Chase JG, Preiser JC, Dickson JL, Pironet A, Chiew YS, Pretty CG, Shaw GM, Benyo B, Moeller K, Safaei S, Tawhai M, Hunter P, Desaive T. Next-generation, personalised, model-based critical care medicine: a state-of-the art review of in silico virtual patient models, methods, and cohorts, and how to validation them. Biomed Eng Online 2018; 17:24. [PMID: 29463246 PMCID: PMC5819676 DOI: 10.1186/s12938-018-0455-y] [Citation(s) in RCA: 84] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2017] [Accepted: 02/12/2018] [Indexed: 01/17/2023] Open
Abstract
Critical care, like many healthcare areas, is under a dual assault from significantly increasing demographic and economic pressures. Intensive care unit (ICU) patients are highly variable in response to treatment, and increasingly aging populations mean ICUs are under increasing demand and their cohorts are increasingly ill. Equally, patient expectations are growing, while the economic ability to deliver care to all is declining. Better, more productive care is thus the big challenge. One means to that end is personalised care designed to manage the significant inter- and intra-patient variability that makes the ICU patient difficult. Thus, moving from current "one size fits all" protocolised care to adaptive, model-based "one method fits all" personalised care could deliver the required step change in the quality, and simultaneously the productivity and cost, of care. Computer models of human physiology are a unique tool to personalise care, as they can couple clinical data with mathematical methods to create subject-specific models and virtual patients to design new, personalised and more optimal protocols, as well as to guide care in real-time. They rely on identifying time varying patient-specific parameters in the model that capture inter- and intra-patient variability, the difference between patients and the evolution of patient condition. Properly validated, virtual patients represent the real patients, and can be used in silico to test different protocols or interventions, or in real-time to guide care. Hence, the underlying models and methods create the foundation for next generation care, as well as a tool for safely and rapidly developing personalised treatment protocols over large virtual cohorts using virtual trials. This review examines the models and methods used to create virtual patients. Specifically, it presents the models types and structures used and the data required. It then covers how to validate the resulting virtual patients and trials, and how these virtual trials can help design and optimise clinical trial. Links between these models and higher order, more complex physiome models are also discussed. In each section, it explores the progress reported up to date, especially on core ICU therapies in glycemic, circulatory and mechanical ventilation management, where high cost and frequency of occurrence provide a significant opportunity for model-based methods to have measurable clinical and economic impact. The outcomes are readily generalised to other areas of medical care.
Collapse
Affiliation(s)
- J. Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Jean-Charles Preiser
- Department of Intensive Care, Erasme University of Hospital, 1070 Brussels, Belgium
| | - Jennifer L. Dickson
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Antoine Pironet
- GIGA In Silico Medicine, University of Liege, 4000 Liege, Belgium
| | - Yeong Shiong Chiew
- Department of Mechanical Engineering, School of Engineering, Monash University Malaysia, 47500 Selangor, Malaysia
| | - Christopher G. Pretty
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Private Bag 4800, Christchurch, New Zealand
| | - Geoffrey M. Shaw
- Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand
| | - Balazs Benyo
- Department of Control Engineering and Information Technology, Budapest University of Technology and Economics, Budapest, Hungary
| | - Knut Moeller
- Department of Biomedical Engineering, Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Soroush Safaei
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Merryn Tawhai
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Peter Hunter
- Auckland Bioengineering Institute, University of Auckland, Auckland, New Zealand
| | - Thomas Desaive
- GIGA In Silico Medicine, University of Liege, 4000 Liege, Belgium
| |
Collapse
|
31
|
Evaluation of pharmacokinetic model designs for subcutaneous infusion of insulin aspart. J Pharmacokinet Pharmacodyn 2017; 44:477-489. [DOI: 10.1007/s10928-017-9535-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Accepted: 08/11/2017] [Indexed: 10/19/2022]
|
32
|
Dickson JL, Stewart KW, Pretty CG, Flechet M, Desaive T, Penning S, Lambermont BC, Benyo B, Shaw GM, Chase JG. Generalisability of a Virtual Trials Method for Glycaemic Control in Intensive Care. IEEE Trans Biomed Eng 2017; 65:1543-1553. [PMID: 28358672 DOI: 10.1109/tbme.2017.2686432] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Elevated blood glucose (BG) concentrations (Hyperglycaemia) are a common complication in critically ill patients. Insulin therapy is commonly used to treat hyperglycaemia, but metabolic variability often results in poor BG control and low BG (hypoglycaemia). OBJECTIVE This paper presents a model-based virtual trial method for glycaemic control protocol design, and evaluates its generalisability across different populations. METHODS Model-based insulin sensitivity (SI) was used to create virtual patients from clinical data from three different ICUs in New Zealand, Hungary, and Belgium. Glycaemic results from simulation of virtual patients under their original protocol (self-simulation) and protocols from other units (cross simulation) were compared. RESULTS Differences were found between the three cohorts in median SI and inter-patient variability in SI. However, hour-to-hour intra-patient variability in SI was found to be consistent between cohorts. Self and cross-simulation results were found to have overall similarity and consistency, though results may differ in the first 24-48 h due to different cohort starting BG and underlying SI. CONCLUSIONS AND SIGNIFICANCE Virtual patients and the virtual trial method were found to be generalisable across different ICUs. This virtual trial method is useful for in silico protocol design and testing, given an understanding of the underlying assumptions and limitations of this method.
Collapse
|
33
|
Kretschmer J, Bibiano C, Laufer B, Docherty PD, Chiew YS, Redmond D, Chase JG, Möller K. Differences in respiratory mechanics estimation with respect to manoeuvres and mathematical models. Biomed Phys Eng Express 2017. [DOI: 10.1088/2057-1976/aa5a31] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
34
|
Docherty P, Geoghegan P, Huetter L, Jermy M, Sellier M. Regressive cross-correlation of pressure signals in the region of stenosis: Insights from particle image velocimetry experimentation. Biomed Signal Process Control 2017. [DOI: 10.1016/j.bspc.2016.09.025] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
35
|
Mansell EJ, Docherty PD, Chase JG. Shedding light on grey noise in diabetes modelling. Biomed Signal Process Control 2017. [DOI: 10.1016/j.bspc.2016.06.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
|
36
|
Kretschmer J, Docherty PD, Riedlinger A, Möller K. Evaluating different approaches to identify a three parameter gas exchange model. CURRENT DIRECTIONS IN BIOMEDICAL ENGINEERING 2016. [DOI: 10.1515/cdbme-2016-0146] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Abstract
Mathematical models can be employed to simulate a patient’s individual physiology and can therefore be used to predict reactions to changes in the therapy. To be clinically useful, those models need to be identifiable from data available at the bedside. Gradient based methods to identify the values of the model parameters that represent the recorded data highly depend on the initial estimates. The proposed work implements a previously developed method to overcome those dependencies to identify a three parameter model of gas exchange. The proposed hierarchical method uses models of lower order related to the three parameter model to calculate valid initial estimates for the parameter identification. The presented approach was evaluated using 12 synthetic patients and compared to a traditional direct approach as well as a global search method. Results show that the direct approach is highly dependent on how well the initial estimates are selected, while the hierarchical approach was able to find correct parameter values in all tested patients.
Collapse
Affiliation(s)
- Jörn Kretschmer
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Paul D. Docherty
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Axel Riedlinger
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Knut Möller
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| |
Collapse
|
37
|
A modified approach to objective surface generation within the Gauss-Newton parameter identification to ignore outlier data points. Biomed Signal Process Control 2016. [DOI: 10.1016/j.bspc.2016.06.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
38
|
Dickson JL, Pretty CG, Alsweiler J, Lynn A, Chase JG. Insulin kinetics and the Neonatal Intensive Care Insulin-Nutrition-Glucose (NICING) model. Math Biosci 2016; 284:61-70. [PMID: 27590773 DOI: 10.1016/j.mbs.2016.08.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Revised: 07/05/2016] [Accepted: 08/24/2016] [Indexed: 10/21/2022]
Abstract
BACKGROUND Models of human glucose-insulin physiology have been developed for a range of uses, with similarly different levels of complexity and accuracy. STAR (Stochastic Targeted) is a model-based approach to glycaemic control. Elevated blood glucose concentrations (hyperglycaemia) are a common complication of stress and prematurity in very premature infants, and have been associated with worsened outcomes and higher mortality. This research identifies and validates the model parameters for model-based glycaemic control in neonatal intensive care. METHODS C-peptide, plasma insulin, and BG from a cohort of 41 extremely pre-term (median age 27.2 [26.2-28.7] weeks) and very low birth weight infants (median birth weight 839 [735-1000] g) are used alongside C-peptide kinetic models to identify model parameters associated with insulin kinetics in the NICING (Neonatal Intensive Care Insulin-Nutrition-Glucose) model. A literature analysis is used to determine models of kidney clearance and body fluid compartment volumes. The full, final NICING model is validated by fitting the model to a cohort of 160 glucose, insulin, and nutrition data records from extremely premature infants from two different NICUs (neonatal intensive care units). RESULTS Six model parameters related to insulin kinetics were identified. The resulting NICING model is more physiologically descriptive than prior model iterations, including clearance pathways of insulin via the liver and kidney, rather than a lumped parameter. In addition, insulin diffusion between plasma and interstitial spaces is evaluated, with differences in distribution volume taken into consideration for each of these spaces. The NICING model was shown to fit clinical data well, with a low model fit error similar to that of previous model iterations. CONCLUSIONS Insulin kinetic parameters have been identified, and the NICING model is presented for glycaemic control neonatal intensive care. The resulting NICING model is more complex and physiologically relevant, with no loss in bedside-identifiability or ability to capture and predict metabolic dynamics.
Collapse
Affiliation(s)
- J L Dickson
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand.
| | - C G Pretty
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand.
| | - J Alsweiler
- Department of Paediatrics: Child and Youth Health, Auckland, New Zealand; Liggins Institute, University of Auckland, Auckland, New Zealand.
| | - A Lynn
- Christchurch Women's Hospital Neonatal Intensive Care Unit, Christchurch, New Zealand.
| | - J G Chase
- Department of Mechanical Engineering, University of Canterbury, Private Bag 4800, Christchurch 8140, New Zealand.
| |
Collapse
|
39
|
Incorporating bolus and infusion pharmacokinetics into the ICING insulin model. Math Biosci 2016; 281:1-8. [PMID: 27580690 DOI: 10.1016/j.mbs.2016.08.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Revised: 08/04/2016] [Accepted: 08/17/2016] [Indexed: 12/25/2022]
Abstract
The ICING model has been successfully used to guide clinical decisions on insulin administration in critical illness. However, insulin pharmacokinetics in the ICING model can be improved to better describe both intravenous (IV) bolus and infusion insulin administration. Patient data from 217 Dynamic Insulin Sensitivity and Secretion Tests (DISST) and 36 Intravenous Glucose Tolerance Tests (IVGTT) from independent dietary intervention studies was used to fit model parameters to a model structure that conforms to known behaviour. The DISST tests measured both endogenous and exogenous IV insulin bolus responses, while the IVGTT measured exogenous IV insulin infusion dynamics. Unidentifiable parameters were given physiologically justified values, with knowledge on relative insulin clearance rates used to constrain parameter values. The resulting whole-cohort description was able to simultaneously describe both IV bolus and infusion dynamics, and improves ICING model descriptive capability. Improved infusion dynamics will allow better description of subcutaneous insulin, the insulin administration route favoured in outpatient care of diabetes.
Collapse
|
40
|
Pironet A, Dauby PC, Chase JG, Docherty PD, Revie JA, Desaive T. Structural identifiability analysis of a cardiovascular system model. Med Eng Phys 2016; 38:433-41. [DOI: 10.1016/j.medengphy.2016.02.005] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2014] [Revised: 12/22/2015] [Accepted: 02/07/2016] [Indexed: 11/26/2022]
|
41
|
Re: Chung et al.’s Letter to the Editor in response to: Early detection of abnormal left ventricular relaxation in acute myocardial ischemia with a quadratic model. Med Eng Phys 2014;36(September (9)):1101–5 by Morimont et al. Med Eng Phys 2015; 37:827. [DOI: 10.1016/j.medengphy.2015.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 05/11/2015] [Accepted: 05/11/2015] [Indexed: 11/21/2022]
|
42
|
Othman NA, Docherty PD, Krebs JD, Bell DA, Chase JG. The necessity of identifying the basal glucose set-point in the IVGTT for patients with Type 2 Diabetes. Biomed Eng Online 2015; 14:18. [PMID: 25881031 PMCID: PMC4350631 DOI: 10.1186/s12938-015-0015-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2014] [Accepted: 02/16/2015] [Indexed: 12/16/2022] Open
Abstract
Background The model-based dynamic insulin sensitivity and secretion test (DISST) uses fasting glucose (G0) as the basal glucose (GB) concentration when assessing insulin sensitivity (SI). However, this model was developed in a healthy, normoglycaemic cohort. We sought to determine the suitability the DISST model has for individuals with established type 2 diabetes (T2D). Methods 14 participants with established T2D were recruited to take part in a dietary intervention study. Insulin-modified intravenous glucose tolerance tests (IM-IVGTT) were undertaken at week 0, 12 and 24 and were used with DISST model to identify GB. A total of 36 tests were conducted across 12 participants throughout the study. Measured G0 and identified GB values were compared using a Kolmogorov-Smirnov (KS) and signed rank (RS) test for the cohort. Results There were significant differences between the G0 and identified GB values in this cohort (prs and pks < 0.0001), although both values were well correlated (R = 0.70). The residual plot demonstrates that the modified model captures the behaviour of the participants more accurately than the original model. Conclusions This analysis has shown that GB is an important variable for modelling the glycaemic behaviour in T2D. These findings suggest that the original DISST model, while appropriate for normoglycaemic cohorts, needs to model basal glucose level as a variable for assessing individuals with established T2D.
Collapse
Affiliation(s)
- Nor Azlan Othman
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8054, New Zealand.
| | - Paul D Docherty
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8054, New Zealand.
| | - Jeremy D Krebs
- Department of Medicine, University of Otago, Wellington, 6242, New Zealand.
| | - Damon A Bell
- School of Medicine and Pharmacology Royal Perth Hospital Unit, The University of Western Australia, Perth, Western Australia, 6009, Australia.
| | - J Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Private Bag 4800, Christchurch, 8054, New Zealand.
| |
Collapse
|
43
|
Redmond D, Chiew YS, van Drunen E, Shaw GM, Chase JG. A minimal algorithm for a minimal recruitment model–model estimation of alveoli opening pressure of an acute respiratory distress syndrome (ARDS) lung. Biomed Signal Process Control 2014. [DOI: 10.1016/j.bspc.2014.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
44
|
Petrov AY, Docherty PD, Sellier M, Chase JG. Multi-frequency inversion in Rayleigh damped Magnetic Resonance Elastography. Biomed Signal Process Control 2014. [DOI: 10.1016/j.bspc.2014.04.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
45
|
Kamoi S, Pretty C, Docherty P, Squire D, Revie J, Chiew YS, Desaive T, Shaw GM, Chase JG. Continuous stroke volume estimation from aortic pressure using zero dimensional cardiovascular model: proof of concept study from porcine experiments. PLoS One 2014; 9:e102476. [PMID: 25033442 PMCID: PMC4102500 DOI: 10.1371/journal.pone.0102476] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2014] [Accepted: 06/18/2014] [Indexed: 11/18/2022] Open
Abstract
Introduction Accurate, continuous, left ventricular stroke volume (SV) measurements can convey large amounts of information about patient hemodynamic status and response to therapy. However, direct measurements are highly invasive in clinical practice, and current procedures for estimating SV require specialized devices and significant approximation. Method This study investigates the accuracy of a three element Windkessel model combined with an aortic pressure waveform to estimate SV. Aortic pressure is separated into two components capturing; 1) resistance and compliance, 2) characteristic impedance. This separation provides model-element relationships enabling SV to be estimated while requiring only one of the three element values to be known or estimated. Beat-to-beat SV estimation was performed using population-representative optimal values for each model element. This method was validated using measured SV data from porcine experiments (N = 3 female Pietrain pigs, 29–37 kg) in which both ventricular volume and aortic pressure waveforms were measured simultaneously. Results The median difference between measured SV from left ventricle (LV) output and estimated SV was 0.6 ml with a 90% range (5th–95th percentile) −12.4 ml–14.3 ml. During periods when changes in SV were induced, cross correlations in between estimated and measured SV were above R = 0.65 for all cases. Conclusion The method presented demonstrates that the magnitude and trends of SV can be accurately estimated from pressure waveforms alone, without the need for identification of complex physiological metrics where strength of correlations may vary significantly from patient to patient.
Collapse
Affiliation(s)
- Shun Kamoi
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
- * E-mail:
| | - Christopher Pretty
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Paul Docherty
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Dougie Squire
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - James Revie
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Yeong Shiong Chiew
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Thomas Desaive
- GIGA Cardiovascular Science, University of Liege, Liege, Belgium
| | - Geoffrey M. Shaw
- Intensive Care Unit, Christchurch Hospital, Christchurch, New Zealand
| | - J. Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
46
|
Docherty PD, Schranz C, Chiew YS, Möller K, Chase JG. Reformulation of the pressure-dependent recruitment model (PRM) of respiratory mechanics. Biomed Signal Process Control 2014. [DOI: 10.1016/j.bspc.2013.12.001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
47
|
Docherty PD, Schranz C, Chase JG, Chiew YS, Möller K. Utility of a novel error-stepping method to improve gradient-based parameter identification by increasing the smoothness of the local objective surface: a case-study of pulmonary mechanics. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2014; 114:e70-e78. [PMID: 23910223 DOI: 10.1016/j.cmpb.2013.06.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2012] [Revised: 04/26/2013] [Accepted: 06/13/2013] [Indexed: 06/02/2023]
Abstract
Accurate model parameter identification relies on accurate forward model simulations to guide convergence. However, some forward simulation methodologies lack the precision required to properly define the local objective surface and can cause failed parameter identification. The role of objective surface smoothness in identification of a pulmonary mechanics model was assessed using forward simulation from a novel error-stepping method and a proprietary Runge-Kutta method. The objective surfaces were compared via the identified parameter discrepancy generated in a Monte Carlo simulation and the local smoothness of the objective surfaces they generate. The error-stepping method generated significantly smoother error surfaces in each of the cases tested (p<0.0001) and more accurate model parameter estimates than the Runge-Kutta method in three of the four cases tested (p<0.0001) despite a 75% reduction in computational cost. Of note, parameter discrepancy in most cases was limited to a particular oblique plane, indicating a non-intuitive multi-parameter trade-off was occurring. The error-stepping method consistently improved or equalled the outcomes of the Runge-Kutta time-integration method for forward simulations of the pulmonary mechanics model. This study indicates that accurate parameter identification relies on accurate definition of the local objective function, and that parameter trade-off can occur on oblique planes resulting prematurely halted parameter convergence.
Collapse
Affiliation(s)
- Paul D Docherty
- Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand.
| | - Christoph Schranz
- Institute of Technical Medicine (ITEM), Furtwangen University, Villengen-Schwenningen, Germany
| | - J Geoffrey Chase
- Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - Yeong Shiong Chiew
- Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - Knut Möller
- Institute of Technical Medicine (ITEM), Furtwangen University, Villengen-Schwenningen, Germany
| |
Collapse
|
48
|
Docherty PD, Chase JG. An in-silico proof-of-concept investigation of a combined glucose-insulin bolus quick dynamic insulin sensitivity test. Biomed Signal Process Control 2014. [DOI: 10.1016/j.bspc.2012.12.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
49
|
Kamoi S, Squire D, Revie J, Pretty C, Docherty P, Chiew YS, Desaive T, Shaw GM, Chase JG. Accuracy of Stroke Volume Estimation via Reservoir Pressure Concept and Three Element Windkessel Model. ACTA ACUST UNITED AC 2014. [DOI: 10.3182/20140824-6-za-1003.01104] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
50
|
Non-identifiability of the Rayleigh damping material model in magnetic resonance elastography. Math Biosci 2013; 246:191-201. [PMID: 24018294 DOI: 10.1016/j.mbs.2013.08.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2013] [Revised: 07/24/2013] [Accepted: 08/23/2013] [Indexed: 01/31/2023]
Abstract
Magnetic Resonance Elastography (MRE) is an emerging imaging modality for quantifying soft tissue elasticity deduced from displacement measurements within the tissue obtained by phase sensitive Magnetic Resonance Imaging (MRI) techniques. MRE has potential to detect a range of pathologies, diseases and cancer formations, especially tumors. The mechanical model commonly used in MRE is linear viscoelasticity (VE). An alternative Rayleigh damping (RD) model for soft tissue attenuation is used with a subspace-based nonlinear inversion (SNLI) algorithm to reconstruct viscoelastic properties, energy attenuation mechanisms and concomitant damping behavior of the tissue-simulating phantoms. This research performs a thorough evaluation of the RD model in MRE focusing on unique identification of RD parameters, μI and ρI. Results show the non-identifiability of the RD model at a single input frequency based on a structural analysis with a series of supporting experimental phantom results. The estimated real shear modulus values (μR) were substantially correct in characterising various material types and correlated well with the expected stiffness contrast of the physical phantoms. However, estimated RD parameters displayed consistent poor reconstruction accuracy leading to unpredictable trends in parameter behaviour. To overcome this issue, two alternative approaches were developed: (1) simultaneous multi-frequency inversion; and (2) parametric-based reconstruction. Overall, the RD model estimates the real shear shear modulus (μR) well, but identifying damping parameters (μI and ρI) is not possible without an alternative approach.
Collapse
|