1
|
Sam F, Shanthi P, Francis DV. Effectiveness of different combinations of phenoxetol and formaldehyde on preservation of histological features in human cadaveric tissues. Med J Armed Forces India 2025; 81:25-31. [PMID: 39872180 PMCID: PMC11763215 DOI: 10.1016/j.mjafi.2023.07.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 07/07/2023] [Indexed: 01/29/2025] Open
Abstract
Background Fixation preserves the tissues in a close to the life-like state by preventing its autolysis and putrefaction. Formalin has long been considered the close to ideal fixative for histological studies. With the awareness of occupational hazards, a few researchers have tried phenoxetol as a secondary preservative which offered comparable histological results to that of formalin. The adoption of phenoxetol as a non-toxic histological fixative of choice for staining purposes will require a process of validation; hence, the study aimed to see the suitability of different proportions of formalin and phenoxetol which can be used as a histological fixative. Methods A few tissue sections (lip, ear lobe, muscle, vessels, and adipose tissue) were taken from a single cadaver before routine formalin-based embalming. The tissues were cut into smaller segments and fixed in 10% formalin, 1% phenoxetol, and in different proportions of 10% formalin and 1% phenoxetol. After the set time of fixation, tissue processing was carried out, and the slides were stained using hematoxylin and eosin (H&E) as well as special stains. The histological features of the tissues were assessed by two observers who were blinded to the fixation process. Results Most of the tissues preserved in 1% phenoxetol stained sufficiently well compared to other fixatives (formalin, phenoxetol + formalin). As the study was done using a standardized protocol followed for 10% formalin, few combinations did not work well. Still, the tissues fixed in 1% phenoxetol gave excellent results. Conclusion We can conclude that for histological studies, 1% phenoxetol can be used as a short-term primary fixative.
Collapse
Affiliation(s)
- Femina Sam
- Assistant Professor (Anatomy), Christian Medical College, Affiliated to the Tamilnadu Dr. MGR Medical University, Vellore, India
| | - Pauline Shanthi
- Associate Professor (Anatomy), Christian Medical College, Affiliated to the Tamilnadu Dr. MGR Medical University, Vellore, India
| | - Deepak Vinod Francis
- Professor (Anatomy), Christian Medical College, Affiliated to the Tamilnadu Dr. MGR Medical University, Vellore, India
| |
Collapse
|
2
|
Sabarinath B, Suresh S, Protyusha GB, Dhanarathna S. Standardization of honey as a tissue fixative for histopathology: A morphometric study. Dent Res J (Isfahan) 2024; 21:24. [PMID: 38807662 PMCID: PMC11132230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 11/10/2023] [Accepted: 12/27/2023] [Indexed: 05/30/2024] Open
Abstract
Background Tissue fixation is a crucial step to preserve the tissues in a life-like state with minimal disruption to its cellular and chemical composition for histopathological examination. The search for an effective alternate tissue fixative to the routinely used formaldehyde has gained interest as constant exposure to formaldehyde has proven to be toxic. Honey, an organic substance with high acidity and hygroscopic nature, exhibits tissue fixative properties and has been used in the present study. The present study aimed to standardize honey as a tissue fixative for histopathology by comparing it with formalin. Materials and Methods In vitro study Oral tissue samples of goat were fixed in 10% honey and 10% formalin solution, respectively, for 24-48 h, followed by routine tissue processing and microscopic examination of 37 slides per group. 2200 epithelial cells (1100 per group) were selected for the computer-aided morphometric image analysis (Fiji-Image J) by three observers. Cell area (CA), cell perimeter (CP), nuclear area (NA), nuclear perimeter (NP), cytoplasmic area (Cyt A), and nuclear-cytoplasmic ratio were the parameters studied. Mann-Whitney U-test (STATA/IC version 16) for inter-group comparison was done and P < 0.05 was considered statistically significant. Results The probability of epithelial cells in the honey-fixed group to have greater NA, NP, and N/C ratio was about 50%-60%. The probability of epithelial cells in formalin-fixed tissues to have greater CA, CP, and Cyt A was about 70%. Conclusion Honey is a better nuclear fixative than formalin. Cytoplasmic shrinkage of epithelial cells should be taken into consideration while fixing tissues with honey.
Collapse
Affiliation(s)
- B. Sabarinath
- Department of Oral Pathology and Microbiology, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India
| | - Shruthi Suresh
- Oral and Maxillofacial Pathologist, Chennai, Tamil Nadu, India
| | - G. B. Protyusha
- Department of Oral Pathology and Microbiology, Meenakshi Ammal Dental College and Hospital, Chennai, Tamil Nadu, India
| | - S. Dhanarathna
- Oral and Maxillofacial Pathologist, Chennai, Tamil Nadu, India
| |
Collapse
|
3
|
Gotur SP, Kamarthi N, Wadhwan V. Sirka: An alternative to the formalin fixative. INDIAN J PATHOL MICR 2024; 67:238-240. [PMID: 38358234 DOI: 10.4103/ijpm.ijpm_510_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2024] Open
Abstract
Formalin fixation is the most essential step of routine histopathology practice. During the last few years, various fixatives have been developed for use in histopathology practice as an alternative to formalin, to overcome its side effects on health. Here we have demonstrated an interesting and novel idea of using sirka or sugar cane vinegar as an alternative to the formalin with the adequate result.
Collapse
Affiliation(s)
- Suhasini P Gotur
- Department of Oral Pathology and Microbiology, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India Department of Oral Medicine and Radiology, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India
| | | | | |
Collapse
|
4
|
Antipova V, Niedermair JF, Siwetz M, Fellner FA, Löffler S, Manhal S, Ondruschka B, Pietras SM, Poilliot AJ, Pretterklieber ML, Wree A, Hammer N. Undergraduate medical student perceptions and learning outcomes related to anatomy training using Thiel- and ethanol-glycerin-embalmed tissues. ANATOMICAL SCIENCES EDUCATION 2023; 16:1144-1157. [PMID: 37337999 DOI: 10.1002/ase.2306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 05/11/2023] [Accepted: 05/18/2023] [Indexed: 06/21/2023]
Abstract
Anatomical dissection is known to serve as an integral tool in teaching gross anatomy, including postgraduate training. A variety of embalming techniques exist, resulting in different haptic and optical tissue properties. This study aimed to objectify learning outcomes and medical student perceptions related to the use of two widely used embalming techniques, namely Thiel and ethanol-glycerin embalming. Between 2020 and 2022, first- and second-year medical students enrolled in the course on topographic anatomy participated in this study. Objective structured practical examinations were carried out for the head, neck, thorax, abdomen, pelvis, and extremity regions following regional dissection just before the oral examinations began. Six to ten numbered tags were marked in prosections of each region in Thiel- and ethanol-glycerin-embalmed specimens. Following the examinations, the students were surveyed regarding the suitability of the two embalming techniques with respect to preservation, colorfastness, tissue pliability, and the suitability in preparing for their anatomy examinations. Consistently higher scores were achieved for the thoracic and abdominal regions in ethanol-glycerin-embalmed specimens when compared to Thiel. No benefit was found for Thiel-embalmed upper or lower extremities. Tissues embalmed with ethanol-glycerin were rated higher for preservation and suitability to achieve the learning objectives, tissue pliability was rated higher for Thiel-embalmed tissues. Ethanol-glycerin embalming appears to offer certain advantages for undergraduate students in recognizing visceral structures, which may align with students' ideas on tissue suitability for their learning. Consequently, the benefits reported for Thiel embalming for postgraduate study unlikely reflect its suitability for novices.
Collapse
Affiliation(s)
- Veronica Antipova
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
| | - Julian F Niedermair
- Central Radiology Institute, Johannes Kepler University Hospital, Linz, Austria
| | - Martin Siwetz
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
| | - Franz A Fellner
- Central Radiology Institute, Johannes Kepler University Hospital, Linz, Austria
- Division of Virtual Morphology, Institute of Anatomy and Cell Biology, Johannes Kepler University, Linz, Austria
| | - Sabine Löffler
- Department of Anatomy, University of Leipzig, Leipzig, Germany
| | - Simone Manhal
- Office of the Vice-Rector for Studies and Teaching, Medical University of Graz, Graz, Austria
| | - Benjamin Ondruschka
- Institute of Legal Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Sandra M Pietras
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
| | | | - Michael L Pretterklieber
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
| | - Andreas Wree
- Institute of Anatomy, Rostock University Medical Center, Rostock, Germany
| | - Niels Hammer
- Division of Macroscopic and Clinical Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
- Department of Orthopedic and Trauma Surgery, University of Leipzig, Leipzig, Germany
- Division of Biomechatronics, Fraunhofer Institute for Machine Tools and Forming Technology Dresden, Dresden, Germany
| |
Collapse
|
5
|
Febrimarsa, Gornik SG, Barreira SN, Salinas‐Saavedra M, Schnitzler CE, Baxevanis AD, Frank U. Randomly incorporated genomic N6-methyldeoxyadenosine delays zygotic transcription initiation in a cnidarian. EMBO J 2023; 42:e112934. [PMID: 37708295 PMCID: PMC10390872 DOI: 10.15252/embj.2022112934] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 06/14/2023] [Accepted: 06/16/2023] [Indexed: 09/16/2023] Open
Abstract
N6-methyldeoxyadenosine (6mA) is a chemical alteration of DNA, observed across all realms of life. Although the functions of 6mA are well understood in bacteria and protists, its roles in animal genomes have been controversial. We show that 6mA randomly accumulates in early embryos of the cnidarian Hydractinia symbiolongicarpus, with a peak at the 16-cell stage followed by clearance to background levels two cell cycles later, at the 64-cell stage-the embryonic stage at which zygotic genome activation occurs in this animal. Knocking down Alkbh1, a putative initiator of animal 6mA clearance, resulted in higher levels of 6mA at the 64-cell stage and a delay in the initiation of zygotic transcription. Our data are consistent with 6mA originating from recycled nucleotides of degraded m6A-marked maternal RNA postfertilization. Therefore, while 6mA does not function as an epigenetic mark in Hydractinia, its random incorporation into the early embryonic genome inhibits transcription. In turn, Alkbh1 functions as a genomic 6mA "cleaner," facilitating timely zygotic genome activation. Given the random nature of genomic 6mA accumulation and its ability to interfere with gene expression, defects in 6mA clearance may represent a hitherto unknown cause of various pathologies.
Collapse
Affiliation(s)
- Febrimarsa
- Centre for Chromosome Biology, School of Biological and Chemical SciencesUniversity of GalwayGalwayRepublic of Ireland
| | - Sebastian G Gornik
- Centre for Chromosome Biology, School of Biological and Chemical SciencesUniversity of GalwayGalwayRepublic of Ireland
- Present address:
Centre for Organismal StudiesHeidelberg UniversityHeidelbergGermany
| | - Sofia N Barreira
- Computational and Statistical Genomics Branch, Division of Intramural ResearchNational Human Genome Research Institute, National Institutes of HealthBethesdaMDUSA
| | - Miguel Salinas‐Saavedra
- Centre for Chromosome Biology, School of Biological and Chemical SciencesUniversity of GalwayGalwayRepublic of Ireland
| | - Christine E Schnitzler
- Whitney Laboratory for Marine BioscienceUniversity of FloridaSt. AugustineFLUSA
- Department of BiologyUniversity of FloridaGainesvilleFLUSA
| | - Andreas D Baxevanis
- Computational and Statistical Genomics Branch, Division of Intramural ResearchNational Human Genome Research Institute, National Institutes of HealthBethesdaMDUSA
| | - Uri Frank
- Centre for Chromosome Biology, School of Biological and Chemical SciencesUniversity of GalwayGalwayRepublic of Ireland
| |
Collapse
|
6
|
Golberg M, Wysiadecki G, Kobos J, Brzeziński P, Polguj M, Clarke E, Barszcz K, Balawender K, Radek M, Żytkowski A. Application of automated immunohistochemistry in anatomical research: A brief review of the method. TRANSLATIONAL RESEARCH IN ANATOMY 2022. [DOI: 10.1016/j.tria.2022.100211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
7
|
Ongaro AE, Ndlovu Z, Sollier E, Otieno C, Ondoa P, Street A, Kersaudy-Kerhoas M. Engineering a sustainable future for point-of-care diagnostics and single-use microfluidic devices. LAB ON A CHIP 2022; 22:3122-3137. [PMID: 35899603 PMCID: PMC9397368 DOI: 10.1039/d2lc00380e] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Accepted: 06/20/2022] [Indexed: 06/15/2023]
Abstract
Single-use, disposable, point-of-care diagnostic devices carry great promise for global health, including meeting urgent needs for testing and diagnosis in places with limited laboratory facilities. Unfortunately, the production and disposal of single-use devices, whether in lateral flow assay, cartridges, cassettes, or lab-on-chip microfluidic format, also poses significant challenges for environmental and human health. Point-of-care devices are commonly manufactured from unsustainable polymeric materials derived from fossil sources. Their disposal often necessitates incineration to reduce infection risk, thereby creating additional release of CO2. Many devices also contain toxic chemicals, such as cyanide derivatives, that are damaging to environmental and human health if not disposed of safely. Yet, in the absence of government regulatory frameworks, safe and sustainable waste management for these novel medical devices is often left unaddressed. There is an urgent need to find novel solutions to avert environmental and human harm from these devices, especially in low- and middle-income countries where waste management infrastructure is often weak and where the use of point-of-care tests is projected to rise in coming years. We review here common materials used in the manufacture of single-use point-of-care diagnostic tests, examine the risks they pose to environmental and human health, and investigate replacement materials that can potentially reduce the impact of microfluidic devices on the production of harmful waste. We propose solutions available to point-of-care test developers to start embedding sustainability at an early stage in their design, and to reduce their non-renewable plastic consumption in research and product development.
Collapse
Affiliation(s)
| | - Zibusiso Ndlovu
- Medecins Sans Frontières (MSF), Southern Africa Medical Unit (SAMU), Cape Town, South Africa
| | | | - Collins Otieno
- African Society for Laboratory Medicine (ASLM), Addis Ababa, Ethiopia
| | - Pascale Ondoa
- African Society for Laboratory Medicine (ASLM), Addis Ababa, Ethiopia
| | - Alice Street
- School of Social and Political Sciences, University of Edinburgh, Edinburgh, UK
| | - Maïwenn Kersaudy-Kerhoas
- School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh, UK.
- Infection Medicine, College of Medicine and Veterinary Medicine University of Edinburgh, Edinburgh, UK
| |
Collapse
|
8
|
Rahman MA, Sultana N, Ayman U, Bhakta S, Afrose M, Afrin M, Haque Z. Alcoholic fixation over formalin fixation: A new, safer option for morphologic and molecular analysis of tissues. Saudi J Biol Sci 2022; 29:175-182. [PMID: 35002406 PMCID: PMC8716893 DOI: 10.1016/j.sjbs.2021.08.075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 08/16/2021] [Accepted: 08/22/2021] [Indexed: 11/05/2022] Open
Abstract
Formalin is a widely used fixative but there is potential public health risks to exposure. Besides, alcoholic fixation is advantageous over formalin fixation because of faster fixation, optimal preservation and safer workplace environment. Following fixation by EMA and 10% neutral buffered formalin (NBF), we analyzed the tissue morphology, antigenic stability, DNA and RNA quantity with quality (OD value). The findings of EMA fixing on both the tissue morphology and molecular characterization, were satisfactory. Specially, EMA was faster in penetration of tissues than NBF, fixed ideally as early as 8 h of fixation whereas improper fixation was evident for NBF. In Hematoxylin and Eosin (H & E) staining, better cellular details with stronger affinity for staining were observed. In immunohistochemistry, better antigenic stability was reported for EMA-fixed tissues. The nucleic acid analysis revealed that total genomic DNA and RNA yield from EMA fixed tissues were significantly higher (P < 0.05) with superior quality than NBF fixed tissues. Our results suggest that EMA could be a potential alternative to NBF for fixation and preservation of tissues. These data provide new insights into an option for a safer working environment to support study and research.
Collapse
Affiliation(s)
- Md Asabur Rahman
- Department of Anatomy and Histology, Faculty of Animal Science and Veterinary Medicine, Patuakhali Science and Technology University, Babugonj, Barisal 8210, Bangladesh
| | - Nasrin Sultana
- Department of Anatomy and Histology, Faculty of Veterinary Science, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| | - Ummay Ayman
- Department of Anatomy and Histology, Faculty of Veterinary Science, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| | - Sonali Bhakta
- Department of Anatomy and Histology, Faculty of Veterinary Science, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| | - Marzia Afrose
- Department of Livestock Science and Veterinary Medicine, Bangabandhu Sheikh Mujibur Rahman Science and Technology University, Gopalganj 8100, Bangladesh
| | - Marya Afrin
- Department of Anatomy and Histology, Faculty of Veterinary Science, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| | - Ziaul Haque
- Department of Anatomy and Histology, Faculty of Veterinary Science, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| |
Collapse
|
9
|
Ghelli F, Cocchi E, Buglisi M, Squillacioti G, Bellisario V, Bono R, Santovito A. The role of phase I, phase II, and DNA-repair gene polymorphisms in the damage induced by formaldehyde in pathologists. Sci Rep 2021; 11:10507. [PMID: 34006906 PMCID: PMC8131755 DOI: 10.1038/s41598-021-89833-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 04/30/2021] [Indexed: 01/16/2023] Open
Abstract
Formaldehyde (FA) is a human carcinogen used as formalin in hospital laboratories. We evaluated its association with human chromosomal aberrations (CAs) and the risk/protective role played by several genetic polymorphisms in this relationship, on a cohort of 57 exposed pathologists vs 48 controls. All subjects were assessed for CAs on peripheral blood lymphocytes and genotyped for the most common cancer-associated gene polymorphisms which could be related with the genotoxic outcome: CYP1A1 exon 7 (A>G), CYP1A1*2A (T>C), CYP2C19*2 (G>A), GSTT1 (Positive/Null), GSTM1 (Positive/null), GSTP1 (A>G), XRCC1 (G399A), XRCC1 (C194T), XRCC1 (A280G), XPD (A751C), XPC exon 15 (A939C), XPC exon 9 (C499T), TNFα - 308 (G>A), IL10 - 1082 (G>A), IL10 - 819 (C>T) and IL6 - 174 (G>C). Air-FA concentration was assessed through personal samplers. The comparison between pathologists and controls showed a significantly higher CAs frequency in pathologists. Significant positive correlations were found between CAs frequency and air-FA concentration while significant associations were found between variation in CAs frequency and the mutated allele for CYP1A1 exon 7 (A>G), CYP2C19*2 (G>A), GSTT1-positive, GSTM1-positive and XRCC1 (G399A). Our study confirms the role of FA as genotoxicity inductor, even in workers chronically exposed to low air-FA levels and reveals the role played by some genetic polymorphisms in this association, highlighting the importance of individual susceptibility biomarkers assessment in occupational health studies.
Collapse
Affiliation(s)
- Federica Ghelli
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5 bis, 10126, Turin, Italy
| | - Enrico Cocchi
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5 bis, 10126, Turin, Italy
| | - Martina Buglisi
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5 bis, 10126, Turin, Italy
| | - Giulia Squillacioti
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5 bis, 10126, Turin, Italy
| | - Valeria Bellisario
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5 bis, 10126, Turin, Italy
| | - Roberto Bono
- Department of Public Health and Pediatrics, University of Turin, Via Santena 5 bis, 10126, Turin, Italy.
| | - Alfredo Santovito
- Department of Life Sciences and Systems Biology, University of Turin, Via Accademia Albertina 13, 10123, Turin, Italy
| |
Collapse
|
10
|
Deepa PR, Nalini V, Surianarayanan M, Krishnakumar S. Towards safer non-volatile tissue fixatives: Evaluation of choline-based ionic liquids for fixing ocular tissues. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2021; 209:111777. [PMID: 33352431 DOI: 10.1016/j.ecoenv.2020.111777] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 11/19/2020] [Accepted: 12/06/2020] [Indexed: 06/12/2023]
Abstract
Volatile organic chemicals (VOCs) are routinely used for processing biological tissue samples in clinical laboratories. Recognizing their serious health and environmental impacts, a few non-volatile green solvents (choline based ionic liquids, ILs) were evaluated as tissue fixatives here. Microscopic evaluation of histo-morphology, fixation and staining quality, and macromolecular integrity (DNA and proteins) were assessed in human eye tissues (sclera, choroid, retinal layers and retinal pigmented epithelium, eyelid and orbit) after IL-fixation. Formalin-fixed tissues were used as standard reference. Microscopic examination revealed favorable histomorphology, tissue fixation and staining characteristics in most tissues immersed in ILs. Time taken to fix, and stability over a period of time (24 h, 48 h, 1 week, 1 month) was also recorded. Electrophoretic analysis revealed stability of cellular proteins and nucleic acids in IL-fixed scleral tissues. Heterogeneity in tissue fixation property relative to the type of ocular tissue, duration of fixation and storage, warrant further design and optimization of ILs to fix biological tissues. The simple cholinium salts based ILs tested here show favorable potential for tissue fixation application, and as an alternative approach to the use of VOCs, towards sustainable biomedical practice.
Collapse
Affiliation(s)
- P R Deepa
- Department of Biological Sciences, Birla Institute of Technology & Science (BITS), Pilani 333 031, Rajasthan, India.
| | - V Nalini
- Department of Biological Sciences, Birla Institute of Technology & Science (BITS), Pilani 333 031, Rajasthan, India; L&T Department of Ocular Pathology, Kamalnayan Bajaj Institute for Research in Vision and Ophthalmology, Vision Research Foundation, Sankara Nethralaya, 18, College Road, 600 006 Chennai, India
| | - M Surianarayanan
- Cell for Industrial Safety and Risk Analysis (CISRA), Central Leather Research Institute (CSIR-CLRI), Adyar, Chennai, India
| | - S Krishnakumar
- L&T Department of Ocular Pathology, Kamalnayan Bajaj Institute for Research in Vision and Ophthalmology, Vision Research Foundation, Sankara Nethralaya, 18, College Road, 600 006 Chennai, India.
| |
Collapse
|
11
|
Shetty JK, Babu HF, Hosapatna Laxminarayana KP. Histomorphological Assessment of Formalin versus Nonformalin Fixatives in Diagnostic Surgical Pathology. J Lab Physicians 2020; 12:271-275. [PMID: 33390677 PMCID: PMC7773438 DOI: 10.1055/s-0040-1722546] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Introduction
Fixation is the critical step in the preservation of tissues in diagnostic pathology. The formalin is an economical and excellent fixative with the inherent property of adequate fixation. The well-established side effects of formalin include mucosal irritation, upper respiratory diseases, and corrosive injury to the gastrointestinal tract. In addition, substantial evidence exists regarding the potential role of formaldehyde as a human carcinogen. The carcinogenic and toxic effects of formalin encourage searching for alternative fixatives for tissue fixation. However, “the formalin dogma” has severely hampered the search for alternative fixatives for many years.
Material and Methods
Ninety tissues of liver and skeletal muscle obtained during autopsies were immersed in adequate amounts of the following fixatives: formalin (10%), methyl alcohol (70%), and acetone (100%). The comparison among the three was made based on time for fixation, preservation of tissue architecture, cell borders, cytoplasm, nuclear contours, chromatin texture, and uniformity of staining.
Results
The tissue preserved in formalin undergoes rapid fixation compared with alcohol and acetone. The tissue architecture, cell border characteristics of alcohol and acetone was found satisfactory compared with formalin. The cytoplasm and nuclear contour were superior with the formalin. The chromatin texture and uniformity of staining were similar with all the three fixatives.
Conclusion
The formalin is considered superior to most of the parameters, whereas both methyl alcohol and acetone showed nearly equivalent scores. Hence, owing to the potential human health hazards and carcinogenicity of formalin, no rational reasons hamper the complete substitution of formalin with alternative fixatives such as alcohol and acetone in diagnostic pathology and medical research.
Collapse
Affiliation(s)
- Jayaprakash Kubalady Shetty
- Department of Pathology, K. S. Hegde Medical Academy, Nitte (Deemed to be University), Mangaluru, Karnataka, India
| | - Hannah Fathima Babu
- Department of Pathology, K. S. Hegde Medical Academy, Nitte (Deemed to be University), Mangaluru, Karnataka, India
| | | |
Collapse
|
12
|
Mucci N, Dugheri S, Rapisarda V, Campagna M, Garzaro G, Farioli A, Cappelli G, Arcangeli G. Occupational exposure to airborne formaldehyde in hospital: setting an automatic sampling system, comparing different monitoring methods and applying them to assess exposure. LA MEDICINA DEL LAVORO 2019; 110:446-458. [PMID: 31846449 PMCID: PMC7809934 DOI: 10.23749/mdl.v110i6.8038] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2018] [Revised: 05/07/2019] [Accepted: 10/07/2019] [Indexed: 12/16/2022]
Abstract
BACKGROUND In recent years, under-vacuum sealing (UVS) and containers with formalin encapsulated in the lid have been proposed for the reduction of occupational exposure to airborne formaldehyde (FA) in healthcare environments. OBJECTIVES We are presenting a study focused on the assessment of FA in hospitals: an automatic sampling system was set, different sampling devices were compared, and the concentration of FA was assessed, following its use in different scenarios. METHODS Three different devices for sampling/measuring FA were compared. They are based on: 1. silica gel cartridges impregnated with 2,4-dinitrophenylhydrazine (2,4-DNPH); 2. SPME® fiber using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine; 3. direct reading commercial instrumentation. Three typical scenarios using FA were investigated: operating theatres where small biopsies are soaked into closed-circuit system 4% FA containers, secretariat of pathology laboratories during the registration of biopsies and pathology laboratories during the filling procedure by UVS and the slicing of biopsies. RESULTS The automatic sampling system allowed short-, long-, and in continuous-sampling time to measure airborne FA. Different sampling devices provided comparable results when tested to assess FA concentration ranging from 0.020-0.320 ppm in a test chamber, although the devices based on 2,4-DNPH were the best in terms of sensitivity and accuracy. The results of 246 samples showed that the FA concentration was less than 0.04 ppm in 91% of the measurements. CONCLUSIONS The automatic methods efficiently allow sampling and measurement of FA in hospital settings. When using safe practices, the concentration of FA is well below occupational limit values.
Collapse
Affiliation(s)
- Nicola Mucci
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Panzacchi S, Gnudi F, Mandrioli D, Montella R, Strollo V, Merrick BA, Belpoggi F, Tibaldi E. Effects of short and long-term alcohol-based fixation on Sprague-Dawley rat tissue morphology, protein and nucleic acid preservation. Acta Histochem 2019; 121:750-760. [PMID: 31277893 DOI: 10.1016/j.acthis.2019.05.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2019] [Revised: 05/29/2019] [Accepted: 05/31/2019] [Indexed: 12/11/2022]
Abstract
Safety concerns on the toxic and carcinogenic effects of formalin exposure have drawn increasing attention to the search for alternative low risk fixatives for processing tissue specimens in laboratories worldwide. Alcohol-based fixatives are considered some of the most promising alternatives. We evaluated the performance of alcohol-fixed paraffin-embedded (AFPE) samples from Sprague-Dawley (SD) rats analyzing tissue morphology, protein and nucleic acid preservation after short and extremely long fixation times (up to 7 years), using formalin-fixed paraffin-embedded (FFPE) samples as a comparator fixative. Following short and long-term alcohol fixation, tissue morphology and cellular details in tissues, evaluated by scoring stained sections (Hematoxylin-Eosin and Mallory's trichrome), were optimally preserved if compared to formalin fixation. Immunoreactivity of proteins (Ki67, CD3, PAX5, CD68), evaluated by immunohistochemistry, showed satisfactory results when the fixation period did not exceed 1 year. Finally, we confirm the superiority of alcohol fixation compared to formalin, in terms of quantity of nucleic acid extracted from paraffin blocks, even after an extremely long time of alcohol fixation. Our results confirm that alcohol fixation is a suitable and safe alternative to formalin for pathological evaluations. There is a need for standardization of formalin-free methods and harmonization of diagnosis in pathology department worldwide.
Collapse
|
14
|
Mastracci L, Gambella A, Bragoni A, Pigozzi S, Pastorino L, Vanni I, Tosi I, Campora M, Fiocca R, Grillo F. Coping with formalin banning in pathology: under vacuum long-term tissue storage with no added formalin. Histochem Cell Biol 2019; 151:501-511. [PMID: 30604285 DOI: 10.1007/s00418-018-1765-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/19/2018] [Indexed: 11/30/2022]
Abstract
Formalin is toxic and has recently been classified as carcinogenic leading to a proposed European formalin ban. But, the pathology use of formalin has however been completely overlooked, and this is proving to be a relevant issue, as no alternative, reliable, tissue fixative is available. Various systems have been proposed to reduce formalin use and exposure; long-term storage and disposal of formalin is also a problem. With this in mind, under vacuum sealing (UVS) systems have been proposed for transportation/storage, however, for how long tissue retains its characteristics (morphological and molecular) is unknown. This study aims to compare histology specimens stored by formalin immersion (FI) and specimens stored after fixation with UVS technique with no additional formalin, at different time periods. Twenty tissue samples (10FI; 10UVS) were stored for different time periods (15 days, 1-2-3-6-12 months) for a total of 120 samples, compared with regard to their morphology, histochemistry, immunoreactivity (24 specific antibodies) and DNA status. All samples showed well-preserved morphology and overlapping staining quality. A significant reduction in immunoreactivity was however identified in the various time periods, particularly for heat pre-treated nuclear antigens, and this commenced earlier (1 month) for FI. UVS storage showed higher DNA content than FI but slightly poorer DNA integrity. These results add important knowledge to the use of UVS in daily practice, as long-term storage of pre-fixed tissue in UVS is not detrimental to the quality of tissue while having the boon of using very little formalin with less operator exposure and lower disposal costs.
Collapse
Affiliation(s)
- Luca Mastracci
- Anatomic Pathology, Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, via De Toni 14, 16132, Genoa, Italy. .,IRCCS Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy.
| | - Alessandro Gambella
- Anatomic Pathology, Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, via De Toni 14, 16132, Genoa, Italy
| | - Alberto Bragoni
- Anatomic Pathology, Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, via De Toni 14, 16132, Genoa, Italy
| | - Simona Pigozzi
- Anatomic Pathology, Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, via De Toni 14, 16132, Genoa, Italy.,IRCCS Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy
| | - Lorenza Pastorino
- Genetics of Rare Tumors Laboratory, Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Viale Benedetto XV, 6, 16132, Genoa, Italy
| | - Irene Vanni
- Genetics of Rare Tumors Laboratory, Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Viale Benedetto XV, 6, 16132, Genoa, Italy
| | - Ilaria Tosi
- IRCCS Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy
| | - Michela Campora
- Anatomic Pathology, Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, via De Toni 14, 16132, Genoa, Italy
| | - Roberto Fiocca
- Anatomic Pathology, Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, via De Toni 14, 16132, Genoa, Italy.,IRCCS Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy
| | - Federica Grillo
- Anatomic Pathology, Department of Surgical Sciences and Integrated Diagnostics (DISC), University of Genoa, via De Toni 14, 16132, Genoa, Italy.,IRCCS Ospedale Policlinico San Martino, Largo R. Benzi 10, 16132, Genoa, Italy
| |
Collapse
|
15
|
Cisne R, Souza AMT, Pereira-Sampaio MA, Babinski MA, Gorniak SL, Papa PC. Tannic Acid Solution: A Better Fixative Solution Than Formalin for Elastin and Collagen-Toxic and Morphological Assessment. Anat Rec (Hoboken) 2018; 301:1544-1550. [DOI: 10.1002/ar.23894] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 02/02/2018] [Accepted: 02/21/2018] [Indexed: 11/06/2022]
Affiliation(s)
- Rafael Cisne
- Department of Morphology, Biomedical Center; Fluminense Federal University; Niterói RJ Brazil
| | - Alessandra M. T. Souza
- Laboratory of Molecular Modeling and QSAR (ModMolQSAR), Faculty of Pharmacy, Center of Health Sciences; Federal University of Rio de Janeiro (UFRJ), 21941-590; Rio de Janeiro RJ Brazil
| | | | - Marcio A. Babinski
- Department of Morphology, Biomedical Center; Fluminense Federal University; Niterói RJ Brazil
| | - Silvana L. Gorniak
- Research Center for Veterinary Toxicology (CEPTOX), Department of Pathology; School of Veterinary Medicine, University of São Paulo; São Paulo Brazil
| | - Paula C. Papa
- Department of Surgery, School of the Veterinary Medicine and Animal Science; University of São Paulo; São Paulo Brazil
| |
Collapse
|
16
|
Chittemsetti S, Nallamala S, Sravya T, Guttikonda VR, Manchikatla PK, Kondamari S. Natural substitutes for formalin: A boon to histopathology!! J Oral Maxillofac Pathol 2018; 22:143. [PMID: 29731573 PMCID: PMC5917524 DOI: 10.4103/jomfp.jomfp_53_16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Introduction: In routine tissue processing, formalin has been proved as efficient as fixative since inception and hazards associated with it are of major safety and health concern. Aim: The aim of this study is to compare the efficacy of natural fixatives such as jaggery and Khandsari over formalin. Materials and Methods: Ninety normal tissue specimen collected during minor oral surgical procedures were included in this study. Thirty specimen each were fixed in 30% jaggery (Group-A), 30% Khandsari (Group-B) and 10% formalin (Group-C). The slides obtained after tissue processing were analyzed for the quality of fixation. The tissue sections were assessed for cellular outline, cytoplasmic details, nuclear details, staining quality and overall morphology. Each criterion was rated on a scale of 1–4. (one for poor and four for excellent). The study was double-blinded and subjected to the Kruskal–Wallis ANOVA and Chi-square test. Results: The cellular outline is excellent in 90% (Group-C) followed by 36.67% (Group-B) of specimens. With respect to cytoplasmic staining 83.33% (Group-C) of tissues showed excellent results followed by 60% (Group-B), 33.33% (Group-A). Nuclear details are excellent in 86.67% (Group-C) followed by 83.33% (Group-B), 36.67% (Group-A) of specimens. With respect to staining quality 93.33% (Group-C) followed by 50% (Group-B), 26.67% (Group-A). Overall morphology is excellent in 90% (Group-C) followed by 46.67% (Group-B). Conclusion: In the present study, Khandsari was on par with formalin and our effort of using Khandsari and jaggery for tissue fixation in human oral tissues yielded good results.
Collapse
Affiliation(s)
- Samatha Chittemsetti
- Department of Oral and Maxillofacial Pathology, Mamata Dental College, Khammam, Telangana, India
| | - Shilpa Nallamala
- Department of Oral and Maxillofacial Pathology, Mamata Dental College, Khammam, Telangana, India
| | - Taneeru Sravya
- Department of Oral and Maxillofacial Pathology, Mamata Dental College, Khammam, Telangana, India
| | | | | | - Sudheerkanth Kondamari
- Department of Oral and Maxillofacial Pathology, Mamata Dental College, Khammam, Telangana, India
| |
Collapse
|
17
|
Ongay S, Langelaar-Makkinje M, Stoop MP, Liu N, Overkleeft H, Luider TM, Groothuis GMM, Bischoff R. Cleavable Crosslinkers as Tissue Fixation Reagents for Proteomic Analysis. Chembiochem 2018; 19:736-743. [PMID: 29356267 DOI: 10.1002/cbic.201700625] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Indexed: 12/17/2022]
Abstract
Formaldehyde fixation is widely used for long-term maintenance of tissue. However, due to formaldehyde-induced crosslinks, fixed tissue proteins are difficult to extract, which hampers mass spectrometry (MS) proteomic analyses. Recent years have seen the use of different combinations of high temperature and solubilizing agents (usually derived from antigen retrieval techniques) to unravel formaldehyde-fixed paraffin-embedded tissue proteomes. However, to achieve protein extraction yields similar to those of fresh-frozen tissue, high-temperature heating is necessary. Such harsh extraction conditions can affect sensitive amino acids and post-translational modifications, resulting in the loss of important information, while still not resulting in protein yields comparable to those of fresh-frozen tissue. Herein, the objective is to evaluate cleavable protein crosslinkers as fixatives that allow tissue preservation and efficient protein extraction from fixed tissue for MS proteomics under mild conditions. With this goal in mind, disuccinimidyl tartrate (DST) and dithiobis(succinimidylpropionate) (DSP) are investigated as cleavable fixating reagents. These compounds crosslink proteins by reacting with amino groups, leading to amide bond formation, and can be cleaved with sodium metaperiodate (cis-diols, DST) or reducing agents (disulfide bonds, DSP), respectively. Results show that cleavable protein crosslinking with DST and DSP allows tissue fixation with morphology preservation comparable to that of formaldehyde. In addition, cleavage of DSP improves protein recovery from fixed tissue by a factor of 18 and increases the number of identified proteins by approximately 20 % under mild extraction conditions compared with those of formaldehyde-fixed paraffin-embedded tissue. A major advantage of DSP is the introduction of well-defined protein modifications that can be taken into account during database searching. In contrast to DSP fixation, DST fixation followed by cleavage with sodium metaperiodate, although effective, results in side reactions that prevent effective protein extraction and interfere with protein identification. Protein crosslinkers that can be cleaved under mild conditions and result in defined modifications, such as DSP, are thus viable alternatives to formaldehyde as tissue fixatives to facilitate protein analysis from paraffin-embedded, fixed tissue.
Collapse
Affiliation(s)
- Sara Ongay
- Department of Analytical Biochemistry, University of Groningen, Antonius Deusinglaan 1, 9713, AV, Groningen, The Netherlands
| | - Miriam Langelaar-Makkinje
- Department Pharmacokinetics, Toxicology and Targeting, University of Groningen, Antonius Deusinglaan 1, 9713, AV, Groningen, The Netherlands
| | - Marcel P Stoop
- Department of Neurology, Erasmus University Medical Center, P. O. Box 1738, 3000 DR, Rotterdam, The Netherlands
| | - Nora Liu
- Department of Bio-Organic Synthesis, Leiden University, P. O. Box 9502, 2300 RA, Leiden, The Netherlands
| | - Hermen Overkleeft
- Department of Bio-Organic Synthesis, Leiden University, P. O. Box 9502, 2300 RA, Leiden, The Netherlands
| | - Theo M Luider
- Department of Neurology, Erasmus University Medical Center, P. O. Box 1738, 3000 DR, Rotterdam, The Netherlands
| | - Geny M M Groothuis
- Department Pharmacokinetics, Toxicology and Targeting, University of Groningen, Antonius Deusinglaan 1, 9713, AV, Groningen, The Netherlands
| | - Rainer Bischoff
- Department of Analytical Biochemistry, University of Groningen, Antonius Deusinglaan 1, 9713, AV, Groningen, The Netherlands
| |
Collapse
|
18
|
Kasetty S, Dwivedi D, Ragavendra TR, Kallianpur S, Gupta S, Prabhakar N. Comparison of efficacy of local anesthetic solution, distilled water and normal saline as emergency fixatives. J Oral Maxillofac Pathol 2018; 22:283. [PMID: 30158792 PMCID: PMC6097356 DOI: 10.4103/jomfp.jomfp_189_16] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Context: Adequate tissue fixation is fundamental to good quality histological sections. Owing to undesirable effects of 10% buffered formalin, its availability in clinics is questionable. Thus, the present study was conducted with a novel approach to fixation, together with the scope of finding fixative properties of more commonly used reagents available at the clinics. Aims: The present study was aimed to compare the efficacy of local anesthetic solution, normal saline (NS) and distilled water (DW) with that of 10% neutral-buffered formalin. Settings and Design: It is a single-blinded study where histological assessment of fixation was done to assert if the tissues procured were sufficient or insufficient for the clinical diagnosis with/without any problems. Subjects and Methods: Forty soft-tissue specimens obtained from 2 goat tongue were used. Tissues each were directly immersed in local anesthesia, DW, NS solution and formalin for 12 and 24 h each and labeled as Group I and Group II, respectively. The sections were evaluated for staining quality and were subjected to statistical analysis. Statistical Analysis Used: Kruskal–Wallis test was employed to assess the differences in histological quality scores. Comparison between the tissues of the two groups was estimated with Mann–Whitney U-test. Kappa Statistic was used to measure the interobserver variation. Results: There was a significant difference (P ≤ 0.05) in the efficacy of all the three emergency fixatives. Conclusions: On the basis of the results obtained, local anesthetic solution can be used as an emergency fixative.
Collapse
Affiliation(s)
- Sowmya Kasetty
- Department of Oral Basic and Clinical Sciences, College of Dentistry, Buraydah, KSA
| | - Dhara Dwivedi
- Department of Oral Pathology, People's College of Dental Science and Research Centre, Bhopal, Madhya Pradesh, India
| | - T Raju Ragavendra
- Department of Oral Basic and Clinical Sciences, College of Dentistry, Buraydah, KSA
| | - Shreenivas Kallianpur
- Department of Oral Pathology, People's College of Dental Science and Research Centre, Bhopal, Madhya Pradesh, India
| | - Sandeep Gupta
- Department of Oral Pathology and Microbiology, RKDF, Bhopal, Madhya Pradesh, India
| | - Nitin Prabhakar
- Department of Oral Maxillofacial Surgery, Ayder Referral Hospital - College of Health Sciences, Mekelle University, Ethiopia
| |
Collapse
|
19
|
Rouzier R, Roulot A, Jeiranian AH, Ram N, Guinebretiere JM, Salomon AV, Gentien D. Denaturing fixatives are compatible with the NanoString nCounter® platform and the Prosigna® assay. N Biotechnol 2017; 36:37-41. [DOI: 10.1016/j.nbt.2017.01.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 12/03/2016] [Accepted: 01/05/2017] [Indexed: 11/29/2022]
|
20
|
d’Ettorre G, Criscuolo M, Mazzotta M. Managing Formaldehyde indoor pollution in anatomy pathology departments. Work 2017; 56:397-402. [DOI: 10.3233/wor-172505] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Affiliation(s)
- Gabriele d’Ettorre
- Local Health Authority, Health Unit of Occupational Prevention and Protection, Brindisi, Italy
| | - Mario Criscuolo
- Department of Anatomy Pathology, “Perrino” Hospital, Brindisi, Italy
| | - Mauro Mazzotta
- Occupational Medicine, University of Salento, Lecce, Italy
| |
Collapse
|
21
|
Cabrera NC, Espinoza JR, Vargas-Jentzsch P, Sandoval P, Ramos LA, Aponte PM. Alcohol-based solutions for bovine testicular tissue fixation. J Vet Diagn Invest 2016; 29:91-99. [DOI: 10.1177/1040638716672252] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Tissue fixation, a central element in histotechnology, is currently performed with chemical compounds potentially harmful for human health and the environment. Therefore, alternative fixatives are being developed, including alcohol-based solutions. We evaluated several ethanol-based mixtures with additives to study fixative penetration rate, tissue volume changes, and morphologic effects in the bovine testis. Fixatives used were Bouin solution, 4% formaldehyde (F4), 70% ethanol (E70), E70 with 1.5% glycerol (E70G), E70 with 5% acetic acid (E70A), E70 with 1.5% glycerol and 5% acetic acid (E70AG), and E70 with 1.5% glycerol, 5% acetic acid, and 1% dimethyl sulfoxide (DMSO; E70AGD). Five-millimeter bovine testicular tissue cubes could be completely penetrated by ethanol-based fixatives and Bouin solution in 2–3 h, whereas F4 required 21 h. Bouin solution produced general tissue shrinkage, whereas the other fixatives (alcohol-based and F4) caused tissue volume expansion. Although Bouin solution is an excellent fixative for testicular tissue, ethanol-based fixatives showed good penetration rates, low tissue shrinkage, and preserved sufficient morphology to allow identification of the stages of the seminiferous epithelium cycle, therefore representing a valid alternative for histotechnology laboratories. Common additives such as acetic acid, glycerol, and DMSO offered marginal benefits for the process of fixation; E70AG showed the best preservation of morphology with excellent nuclear detail, close to that of Bouin solution.
Collapse
Affiliation(s)
- Nelson C. Cabrera
- Ecuadorian Agency for Quality Assurance in Agriculture (AGROCALIDAD), Tumbaco, Ecuador (Cabrera, Espinoza, Vargas-Jentzsch, Sandoval, Ramos, Aponte)
- Departamento de Ciencias Nucleares, Facultad de Ingeniería Química y Agroindustria, Escuela Politécnica Nacional, Quito, Ecuador (Vargas-Jentzsch)
- Colegio de Ciencias Biológicas y Ambientales, Universidad San Francisco de Quito USFQ, Quito, Ecuador (Aponte)
| | - Jorge R. Espinoza
- Ecuadorian Agency for Quality Assurance in Agriculture (AGROCALIDAD), Tumbaco, Ecuador (Cabrera, Espinoza, Vargas-Jentzsch, Sandoval, Ramos, Aponte)
- Departamento de Ciencias Nucleares, Facultad de Ingeniería Química y Agroindustria, Escuela Politécnica Nacional, Quito, Ecuador (Vargas-Jentzsch)
- Colegio de Ciencias Biológicas y Ambientales, Universidad San Francisco de Quito USFQ, Quito, Ecuador (Aponte)
| | - Paul Vargas-Jentzsch
- Ecuadorian Agency for Quality Assurance in Agriculture (AGROCALIDAD), Tumbaco, Ecuador (Cabrera, Espinoza, Vargas-Jentzsch, Sandoval, Ramos, Aponte)
- Departamento de Ciencias Nucleares, Facultad de Ingeniería Química y Agroindustria, Escuela Politécnica Nacional, Quito, Ecuador (Vargas-Jentzsch)
- Colegio de Ciencias Biológicas y Ambientales, Universidad San Francisco de Quito USFQ, Quito, Ecuador (Aponte)
| | - Patricio Sandoval
- Ecuadorian Agency for Quality Assurance in Agriculture (AGROCALIDAD), Tumbaco, Ecuador (Cabrera, Espinoza, Vargas-Jentzsch, Sandoval, Ramos, Aponte)
- Departamento de Ciencias Nucleares, Facultad de Ingeniería Química y Agroindustria, Escuela Politécnica Nacional, Quito, Ecuador (Vargas-Jentzsch)
- Colegio de Ciencias Biológicas y Ambientales, Universidad San Francisco de Quito USFQ, Quito, Ecuador (Aponte)
| | - Luis A. Ramos
- Ecuadorian Agency for Quality Assurance in Agriculture (AGROCALIDAD), Tumbaco, Ecuador (Cabrera, Espinoza, Vargas-Jentzsch, Sandoval, Ramos, Aponte)
- Departamento de Ciencias Nucleares, Facultad de Ingeniería Química y Agroindustria, Escuela Politécnica Nacional, Quito, Ecuador (Vargas-Jentzsch)
- Colegio de Ciencias Biológicas y Ambientales, Universidad San Francisco de Quito USFQ, Quito, Ecuador (Aponte)
| | - Pedro M. Aponte
- Ecuadorian Agency for Quality Assurance in Agriculture (AGROCALIDAD), Tumbaco, Ecuador (Cabrera, Espinoza, Vargas-Jentzsch, Sandoval, Ramos, Aponte)
- Departamento de Ciencias Nucleares, Facultad de Ingeniería Química y Agroindustria, Escuela Politécnica Nacional, Quito, Ecuador (Vargas-Jentzsch)
- Colegio de Ciencias Biológicas y Ambientales, Universidad San Francisco de Quito USFQ, Quito, Ecuador (Aponte)
| |
Collapse
|
22
|
Mandrioli D, Belpoggi F, Silbergeld EK, Perry MJ. Aneuploidy: a common and early evidence-based biomarker for carcinogens and reproductive toxicants. Environ Health 2016; 15:97. [PMID: 27729050 PMCID: PMC5059969 DOI: 10.1186/s12940-016-0180-6] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2016] [Accepted: 09/28/2016] [Indexed: 05/29/2023]
Abstract
Aneuploidy, defined as structural and numerical aberrations of chromosomes, continues to draw attention as an informative effect biomarker for carcinogens and male reproductive toxicants. It has been well documented that aneuploidy is a hallmark of cancer. Aneuploidies in oocytes and spermatozoa contribute to infertility, pregnancy loss and a number of congenital abnormalities, and sperm aneuploidy is associated with testicular cancer. It is striking that several carcinogens induce aneuploidy in somatic cells, and also adversely affect the chromosome compliment of germ cells. In this paper we review 1) the contributions of aneuploidy to cancer, infertility, and developmental abnormalities; 2) techniques for assessing aneuploidy in precancerous and malignant lesions and in sperm; and 3) the utility of aneuploidy as a biomarker for integrated chemical assessments of carcinogenicity, and reproductive and developmental toxicity.
Collapse
Affiliation(s)
- Daniele Mandrioli
- Cesare Maltoni Cancer Research Center, Ramazzini Institute, 40010 Bentivoglio, Bologna, Italy
| | - Fiorella Belpoggi
- Cesare Maltoni Cancer Research Center, Ramazzini Institute, 40010 Bentivoglio, Bologna, Italy
| | - Ellen K. Silbergeld
- Department of Environmental Health Sciences, Johns Hopkins Bloomberg School of Public Health, 21205 Baltimore, MD USA
| | - Melissa J. Perry
- Department of Environmental and Occupational Health, Milken Institute School of Public Health, The George Washington University, 950 New Hampshire Ave. NW, 4th Floor, Washington, DC 20052 USA
| |
Collapse
|
23
|
KINFix--A formalin-free non-commercial fixative optimized for histological, immunohistochemical and molecular analyses of neurosurgical tissue specimens. Clin Neuropathol 2016; 35:3-12. [PMID: 26521938 PMCID: PMC4766796 DOI: 10.5414/np300907] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/16/2015] [Indexed: 12/04/2022] Open
Abstract
An optimal fixative should ideally combine the advantages of formalin fixation and freezing, allowing for good preservation of histology and molecular components, easy handling and storage, lack of toxicity, and low costs. Most of these criteria are fulfilled by ethanol-based solutions, and due to our good experience with the commercial RCL2 fixative, reflected by our published single-center trial, we initiated a multicenter ring trial. However, during its course, RCL2 was discontinued on the market. Therefore, we created our own agent, KINFix, composed of the same main constituents as RCL2, and employed it in our laboratory with similar results. Here we present our evaluation of the three fixatives formalin, RCL2, and KINFix from the perspective of histopathology as well as nucleic acid and protein analyses in comparison to fresh frozen tissues together with the multicenter ring trial data for RCL2. We observe that RCL2 and KINFix offer comparable histomorphology and superior template for molecular analyses than formalin. Moreover, KINFix as freely available fixative might overcome some of the difficulties related to the commercial agents. Therefore, we conclude that KINFix might be an attractive complement to formalin in tissue processing and advocate its use in neuropathological practice.
Collapse
|
24
|
Roemen GM, zur Hausen A, Speel EJM. Adequate tissue for adequate diagnosis: what do we really need? Lung Cancer 2015. [DOI: 10.1183/2312508x.10010014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
25
|
Bonin S, Stanta G. Nucleic acid extraction methods from fixed and paraffin-embedded tissues in cancer diagnostics. Expert Rev Mol Diagn 2014; 13:271-82. [DOI: 10.1586/erm.13.14] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
26
|
Zanini C, Forni M. The cell block technique revisited for cells cultured in adherence and as "spheres". Histochem Cell Biol 2013; 140:685-90. [PMID: 24013649 DOI: 10.1007/s00418-013-1139-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/23/2013] [Indexed: 12/01/2022]
Abstract
A simple modification of the cell block technique for cultured cells grown in different conditions and suitable for the construction of tissue micro arrays (TMA) is described. The application of mechanical stirring during clot formation allows the uniform dispersion of cells in the fibrin mesh, thus increasing the final volume of the embedded material of evenly distributed cells. This technique is easily applied to spheres-obtained from cell lines cultured under appropriate conditions-that are enriched in stem cells. The possibility of constructing TMA using cell lines (grown in adherence and as spheres) and samples of the corresponding tumors or normal tissues may allow the direct comparison of original tumors with in vitro-expanded cell lines.
Collapse
Affiliation(s)
- Cristina Zanini
- EuroClone S.p.A Research Laboratory, Molecular Biotechnology Centre (MBC), University of Turin, Turin, Italy,
| | | |
Collapse
|
27
|
Zanini C, Ercole E, Mandili G, Salaroli R, Poli A, Renna C, Papa V, Cenacchi G, Forni M. Medullospheres from DAOY, UW228 and ONS-76 cells: increased stem cell population and proteomic modifications. PLoS One 2013; 8:e63748. [PMID: 23717474 PMCID: PMC3663798 DOI: 10.1371/journal.pone.0063748] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Accepted: 04/05/2013] [Indexed: 12/18/2022] Open
Abstract
Background Medulloblastoma (MB) is an aggressive pediatric tumor of the Central Nervous System (CNS) usually treated according to a refined risk stratification. The study of cancer stem cells (CSC) in MB is a promising approach aimed at finding new treatment strategies. Methodology/Principal Findings The CSC compartment was studied in three characterized MB cell lines (DAOY, UW228 and ONS-76) grown in standard adhesion as well as being grown as spheres, which enables expansion of the CSC population. MB cell lines, grown in adherence and as spheres, were subjected to morphologic analysis at the light and electron microscopic level, as well as cytofluorimetric determinations. Medullospheres (MBS) were shown to express increasingly immature features, along with the stem cells markers: CD133, Nestin and β-catenin. Proteomic analysis highlighted the differences between MB cell lines, demonstrating a unique protein profile for each cell line, and minor differences when grown as spheres. In MBS, MALDI-TOF also identified some proteins, that have been linked to tumor progression and resistance, such as Nucleophosmin (NPM). In addition, immunocytochemistry detected Sox-2 as a stemness marker of MBS, as well as confirming high NPM expression. Conclusions/Significance Culture conditioning based on low attachment flasks and specialized medium may provide new data on the staminal compartment of CNS tumors, although a proteomic profile of CSC is still elusive for MB.
Collapse
Affiliation(s)
- Cristina Zanini
- EuroClone S.p.A Research Laboratory, Molecular Biotechnology Centre-MBC, University of Turin, Turin, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|