1
|
Melbacke A, Salhotra A, Ušaj M, Månsson A. Improved longevity of actomyosin in vitro motility assays for sustainable lab-on-a-chip applications. Sci Rep 2024; 14:22768. [PMID: 39354041 PMCID: PMC11445438 DOI: 10.1038/s41598-024-73457-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 09/17/2024] [Indexed: 10/03/2024] Open
Abstract
In the in vitro motility assay (IVMA), actin filaments are observed while propelled by surface-adsorbed myosin motor fragments such as heavy meromyosin (HMM). In addition to fundamental studies, the IVMA is the basis for a range of lab-on-a-chip applications, e.g. transport of cargoes in nanofabricated channels in nanoseparation/biosensing or the solution of combinatorial mathematical problems in network-based biocomputation. In these applications, prolonged myosin function is critical as is the potential to repeatedly exchange experimental solutions without functional deterioration. We here elucidate key factors of importance in these regards. Our findings support a hypothesis that early deterioration in the IVMA is primarily due to oxygen entrance into in vitro motility assay flow cells. In the presence of a typically used oxygen scavenger mixture (glucose oxidase, glucose, and catalase), this leads to pH reduction by a glucose oxidase-catalyzed reaction between glucose and oxygen but also contributes to functional deterioration by other mechanisms. Our studies further demonstrate challenges associated with evaporation and loss of actin filaments with time. However, over 8 h at 21-26 °C, there is no significant surface desorption or denaturation of HMM if solutions are exchanged manually every 30 min. We arrive at an optimized protocol with repeated exchange of carefully degassed assay solution of 45 mM ionic strength, at 30 min intervals. This is sufficient to maintain the high-quality function in an IVMA over 8 h at 21-26 °C, provided that fresh actin filaments are re-supplied in connection with each assay solution exchange. Finally, we demonstrate adaptation to a microfluidic platform and identify challenges that remain to be solved for real lab-on-a-chip applications.
Collapse
Affiliation(s)
- Andreas Melbacke
- Department of Chemistry and Biomedical Sciences, Linnaeus University, 39182, Kalmar, Sweden
| | - Aseem Salhotra
- Department of Chemistry and Biomedical Sciences, Linnaeus University, 39182, Kalmar, Sweden
| | - Marko Ušaj
- Department of Chemistry and Biomedical Sciences, Linnaeus University, 39182, Kalmar, Sweden.
| | - Alf Månsson
- Department of Chemistry and Biomedical Sciences, Linnaeus University, 39182, Kalmar, Sweden.
| |
Collapse
|
2
|
Rahman MA, Reuther C, Lindberg FW, Mengoni M, Salhotra A, Heldt G, Linke H, Diez S, Månsson A. Regeneration of Assembled, Molecular-Motor-Based Bionanodevices. NANO LETTERS 2019; 19:7155-7163. [PMID: 31512480 DOI: 10.1021/acs.nanolett.9b02738] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The guided gliding of cytoskeletal filaments, driven by biomolecular motors on nano/microstructured chips, enables novel applications in biosensing and biocomputation. However, expensive and time-consuming chip production hampers the developments. It is therefore important to establish protocols to regenerate the chips, preferably without the need to dismantle the assembled microfluidic devices which contain the structured chips. We here describe a novel method toward this end. Specifically, we use the small, nonselective proteolytic enzyme, proteinase K to cleave all surface-adsorbed proteins, including myosin and kinesin motors. Subsequently, we apply a detergent (5% SDS or 0.05% Triton X100) to remove the protein remnants. After this procedure, fresh motor proteins and filaments can be added for new experiments. Both, silanized glass surfaces for actin-myosin motility and pure glass surfaces for microtubule-kinesin motility were repeatedly regenerated using this approach. Moreover, we demonstrate the applicability of the method for the regeneration of nano/microstructured silicon-based chips with selectively functionalized areas for supporting or suppressing gliding motility for both motor systems. The results substantiate the versatility and a promising broad use of the method for regenerating a wide range of protein-based nano/microdevices.
Collapse
Affiliation(s)
- Mohammad A Rahman
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar , Sweden , 39182
| | - Cordula Reuther
- B CUBE - Center for Molecular Bioengineering , Technische Universität Dresden , Sachsen , Germany , 01062
- Max Planck Institute of Molecular Cell Biology and Genetics , 01307 Dresden , Germany
| | | | - Martina Mengoni
- B CUBE - Center for Molecular Bioengineering , Technische Universität Dresden , Sachsen , Germany , 01062
- Max Planck Institute of Molecular Cell Biology and Genetics , 01307 Dresden , Germany
| | - Aseem Salhotra
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar , Sweden , 39182
| | - Georg Heldt
- Fraunhofer Institute for Electronic Nano Systems , Chemnitz , Germany 09126
| | | | - Stefan Diez
- B CUBE - Center for Molecular Bioengineering , Technische Universität Dresden , Sachsen , Germany , 01062
- Max Planck Institute of Molecular Cell Biology and Genetics , 01307 Dresden , Germany
| | - Alf Månsson
- Department of Chemistry and Biomedical Sciences , Linnaeus University , Kalmar , Sweden , 39182
| |
Collapse
|
3
|
Affiliation(s)
- Gadiel Saper
- Department of Biomedical Engineering, Columbia University, New York, New York 10027, United States
| | - Henry Hess
- Department of Biomedical Engineering, Columbia University, New York, New York 10027, United States
| |
Collapse
|
4
|
Chaudhuri S, Korten T, Korten S, Milani G, Lana T, Te Kronnie G, Diez S. Label-Free Detection of Microvesicles and Proteins by the Bundling of Gliding Microtubules. NANO LETTERS 2018; 18:117-123. [PMID: 29202578 DOI: 10.1021/acs.nanolett.7b03619] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Development of miniaturized devices for the rapid and sensitive detection of analyte is crucial for various applications across healthcare, pharmaceutical, environmental, and other industries. Here, we report on the detection of unlabeled analyte by using fluorescently labeled, antibody-conjugated microtubules in a kinesin-1 gliding motility assay. The detection principle is based on the formation of fluorescent supramolecular assemblies of microtubule bundles and spools in the presence of multivalent analytes. We demonstrate the rapid, label-free detection of CD45+ microvesicles derived from leukemia cells. Moreover, we employ our platform for the label-free detection of multivalent proteins at subnanomolar concentrations, as well as for profiling the cross-reactivity between commercially available secondary antibodies. As the detection principle is based on the molecular recognition between antigen and antibody, our method can find general application where it identifies any analyte, including clinically relevant microvesicles and proteins.
Collapse
Affiliation(s)
- Samata Chaudhuri
- B CUBE - Center for Molecular Bioengineering, TU Dresden , 01069 Dresden, Germany
- Max Planck Institute of Molecular Cell Biology and Genetics , 01307 Dresden, Germany
| | - Till Korten
- B CUBE - Center for Molecular Bioengineering, TU Dresden , 01069 Dresden, Germany
- Max Planck Institute of Molecular Cell Biology and Genetics , 01307 Dresden, Germany
| | - Slobodanka Korten
- B CUBE - Center for Molecular Bioengineering, TU Dresden , 01069 Dresden, Germany
- Max Planck Institute of Molecular Cell Biology and Genetics , 01307 Dresden, Germany
| | - Gloria Milani
- Department of Women's and Children's Health, University of Padova , 35128 Padova, Italy
| | - Tobia Lana
- Department of Women's and Children's Health, University of Padova , 35128 Padova, Italy
| | - Geertruy Te Kronnie
- Department of Women's and Children's Health, University of Padova , 35128 Padova, Italy
| | - Stefan Diez
- B CUBE - Center for Molecular Bioengineering, TU Dresden , 01069 Dresden, Germany
- Max Planck Institute of Molecular Cell Biology and Genetics , 01307 Dresden, Germany
| |
Collapse
|
5
|
Kumar S, Mansson A. Covalent and non-covalent chemical engineering of actin for biotechnological applications. Biotechnol Adv 2017; 35:867-888. [PMID: 28830772 DOI: 10.1016/j.biotechadv.2017.08.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2017] [Revised: 08/09/2017] [Accepted: 08/16/2017] [Indexed: 12/26/2022]
Abstract
The cytoskeletal filaments are self-assembled protein polymers with 8-25nm diameters and up to several tens of micrometres length. They have a range of pivotal roles in eukaryotic cells, including transportation of intracellular cargoes (primarily microtubules with dynein and kinesin motors) and cell motility (primarily actin and myosin) where muscle contraction is one example. For two decades, the cytoskeletal filaments and their associated motor systems have been explored for nanotechnological applications including miniaturized sensor systems and lab-on-a-chip devices. Several developments have also revolved around possible exploitation of the filaments alone without their motor partners. Efforts to use the cytoskeletal filaments for applications often require chemical or genetic engineering of the filaments such as specific conjugation with fluorophores, antibodies, oligonucleotides or various macromolecular complexes e.g. nanoparticles. Similar conjugation methods are also instrumental for a range of fundamental biophysical studies. Here we review methods for non-covalent and covalent chemical modifications of actin filaments with focus on critical advantages and challenges of different methods as well as critical steps in the conjugation procedures. We also review potential uses of the engineered actin filaments in nanotechnological applications and in some key fundamental studies of actin and myosin function. Finally, we consider possible future lines of investigation that may be addressed by applying chemical conjugation of actin in new ways.
Collapse
Affiliation(s)
- Saroj Kumar
- Department of Biotechnology, Delhi Technological University, Delhi 110042, India; Department of Chemistry and Biomedical Sciences, Faculty of Health and Life Sciences, Linnaeus University, SE-391 82 Kalmar, Sweden.
| | - Alf Mansson
- Department of Chemistry and Biomedical Sciences, Faculty of Health and Life Sciences, Linnaeus University, SE-391 82 Kalmar, Sweden.
| |
Collapse
|
6
|
Lard M, ten Siethoff L, Generosi J, Persson M, Linke H, Månsson A. Nanowire-imposed geometrical control in studies of actomyosin motor function. IEEE Trans Nanobioscience 2015; 14:289-97. [PMID: 25823040 DOI: 10.1109/tnb.2015.2412036] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Recently, molecular motor gliding assays with actin and myosin from muscle have been realized on semiconductor nanowires coated with Al2O3. This opens for unique nanotechnological applications and novel fundamental studies of actomyosin motor function. Here, we provide a comparison of myosin-driven actin filament motility on Al2O3 to both nitrocellulose and trimethylchlorosilane derivatized surfaces. We also show that actomyosin motility on the less than 200 nm wide tips of arrays of Al2O3-coated nanowires can be used to control the number, and density, of myosin-actin attachment points. Results obtained using nanowire arrays with different inter-wire spacing are consistent with the idea that the actin filament sliding velocity is determined both by the total number and the average density of attached myosin heads along the actin filament. Further, the results are consistent with buckling of long myosin-free segments of the filaments as a factor underlying reduced velocity. On the other hand, the findings do not support a mechanistic role in decreasing velocity, of increased nearest neighbor distance between available myosin heads. Our results open up for more advanced studies that may use nanowire-based structures for fundamental investigations of molecular motors, including the possibility to create a nanowire-templated bottom-up assembly of 3D, muscle-like structures.
Collapse
|