Feng Q, Bešević J, Conroy M, Omiyale W, Lacey B, Allen N. Comparison of body composition measures assessed by bioelectrical impedance analysis versus dual-energy X-ray absorptiometry in the United Kingdom Biobank. Clin Nutr ESPEN 2024; 63:214-225. [PMID: 38970786 DOI: 10.1016/j.clnesp.2024.06.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2024] [Revised: 06/04/2024] [Accepted: 06/25/2024] [Indexed: 07/08/2024]
Abstract
BACKGROUND Bioelectrical impedance analysis (BIA) and dual-energy X-ray absorptiometry (DXA) serves as common modalities for body composition assessment. This study was aimed to evaluate the agreement between BIA and DXA measures in UK Biobank. METHODS UK Biobank participants with body fat mass (FM) and fat-free mass (FFM) estimates obtained through BIA (Tanita BC418MA) and DXA concurrently were included. Correlation between BIA and DXA-derived estimates were assessed with Lin's concordance correlation coefficients. Bland-Altman and Passing-Boblok analyses were performed to quantify the difference and agreement between BIA and DXA. Multivariable linear regression was used to identify predictors influencing the differences. Finally, prediction models were developed to calibrate BIA measures against DXA. RESULTS The analysis included 34437 participants (female 51.4%, mean age 64.1 years at imaging assessment). BIA and DXA measurements were highly correlated (Lin's concordance correlation coefficient 0.94 for FM and 0.94 for FFM). BIA (Tanita BC418MA) underestimates FM overall by 1.84 kg (23.77 vs. 25.61, p < 0.01), and overestimated FFM overall by 2.56 kg (52.49 vs. 49.93, p < 0.01). The BIA-DXA differences were associated with FM, FFM, BMI and waist circumference. The developed prediction models showed overall good performance in calibrating BIA data. CONCLUSION Our analysis exhibited strong correlation between BIA (Tanita BC418MA)- and DXA-derived body composition measures at a population level in UK Biobank. However, the BIA-DXA differences were observed at individual level and associated with individual anthropometric measures. Future studies may explore the use of prediction models to enhance the calibration of BIA measures for more accurate assessments in UK Biobank.
Collapse
Affiliation(s)
- Qi Feng
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom; JC School of Public Health and Primary Care, The Chinese University of Hong Kong, Hong Kong, China.
| | - Jelena Bešević
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| | - Megan Conroy
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| | - Wemimo Omiyale
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| | - Ben Lacey
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom.
| | - Naomi Allen
- Nuffield Department of Population Health, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
2
|
Thanaj M, Basty N, Whitcher B, Sorokin EP, Liu Y, Srinivasan R, Cule M, Thomas EL, Bell JD. Precision MRI phenotyping of muscle volume and quality at a population scale. Front Physiol 2024; 15:1288657. [PMID: 38370011 PMCID: PMC10869600 DOI: 10.3389/fphys.2024.1288657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 01/09/2024] [Indexed: 02/20/2024] Open
Abstract
Introduction: Magnetic resonance imaging (MRI) enables direct measurements of muscle volume and quality, allowing for an in-depth understanding of their associations with anthropometric traits, and health conditions. However, it is unclear which muscle volume measurements: total muscle volume, regional measurements, measurements of muscle quality: intermuscular adipose tissue (IMAT) or proton density fat fraction (PDFF), are most informative and associate with relevant health conditions such as dynapenia and frailty. Methods: We have measured image-derived phenotypes (IDPs) including total and regional muscle volumes and measures of muscle quality, derived from the neck-to-knee Dixon images in 44,520 UK Biobank participants. We further segmented paraspinal muscle from 2D quantitative MRI to quantify muscle PDFF and iron concentration. We defined dynapenia based on grip strength below sex-specific cut-off points and frailty based on five criteria (weight loss, exhaustion, grip strength, low physical activity and slow walking pace). We used logistic regression to investigate the association between muscle volume and quality measurements and dynapenia and frailty. Results: Muscle volumes were significantly higher in male compared with female participants, even after correcting for height while, IMAT (corrected for muscle volume) and paraspinal muscle PDFF were significantly higher in female compared with male participants. From the overall cohort, 7.6% (N = 3,261) were identified with dynapenia, and 1.1% (N = 455) with frailty. Dynapenia and frailty were positively associated with age and negatively associated with physical activity levels. Additionally, reduced muscle volume and quality measurements were associated with both dynapenia and frailty. In dynapenia, muscle volume IDPs were most informative, particularly total muscle exhibiting odds ratios (OR) of 0.392, while for frailty, muscle quality was found to be most informative, in particular thigh IMAT volume indexed to height squared (OR = 1.396), both with p-values below the Bonferroni-corrected threshold (p < 8.8 × 10 - 5 ). Conclusion: Our fully automated method enables the quantification of muscle volumes and quality suitable for large population-based studies. For dynapenia, muscle volumes particularly those including greater body coverage such as total muscle are the most informative, whilst, for frailty, markers of muscle quality were the most informative IDPs. These results suggest that different measurements may have varying diagnostic values for different health conditions.
Collapse
Affiliation(s)
- Marjola Thanaj
- Research Centre for Optimal Health, School of Life Sciences, University of Westminster, London, United Kingdom
| | - Nicolas Basty
- Research Centre for Optimal Health, School of Life Sciences, University of Westminster, London, United Kingdom
| | - Brandon Whitcher
- Research Centre for Optimal Health, School of Life Sciences, University of Westminster, London, United Kingdom
| | - Elena P. Sorokin
- Calico Life Sciences LLC, South San Francisco, CA, United States
| | - Yi Liu
- Calico Life Sciences LLC, South San Francisco, CA, United States
| | | | - Madeleine Cule
- Calico Life Sciences LLC, South San Francisco, CA, United States
| | - E. Louise Thomas
- Research Centre for Optimal Health, School of Life Sciences, University of Westminster, London, United Kingdom
| | - Jimmy D. Bell
- Research Centre for Optimal Health, School of Life Sciences, University of Westminster, London, United Kingdom
| |
Collapse
|
3
|
Salvadego D, Tringali G, De Micheli R, Sartorio A. Respiratory Muscle Interval Training Improves Exercise Capacity in Obese Adolescents during a 3-Week In-Hospital Multidisciplinary Body Weight Reduction Program. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 20:487. [PMID: 36612808 PMCID: PMC9819313 DOI: 10.3390/ijerph20010487] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/20/2022] [Accepted: 12/23/2022] [Indexed: 06/17/2023]
Abstract
The purpose of this study was to determine whether a novel approach of interval training targeted to the respiratory muscles (RMIT; normocapnic hyperpnea with resistance) in addition to a multidisciplinary in-hospital body weight reduction program (BWRP) was able to improve the integrative response to exercise in young patients with obesity. Nine male patients (17.9 ± 4.9 (x ± SD) years; 113.8 ± 16.3 kg) underwent 12 sessions of RMIT and eight age-and sex-matched patients underwent 12 sessions of a sham protocol (CTRL) during the same 3-week BWRP. Before and after the interventions the patients performed an incremental and a heavy-intensity constant work-rate (CWR>GET) cycling exercise to voluntary exhaustion. Body mass decreased by ~4.0 kg after both RMIT (p = 0.0001) and CTRL (p = 0.0002). Peak pulmonary O2 uptake (V˙O2) increased after RMIT (p = 0.02) and CTRL (p = 0.0007). During CWR>GET at ISO-time, V˙O2 (p = 0.0007), pulmonary ventilation (p = 0.01), heart rate (p = 0.02), perceived respiratory discomfort (RPER; p = 0.03) and leg effort (p = 0.0003) decreased after RMIT; only RPER (p = 0.03) decreased after CTRL. Time to exhaustion increased after RMIT (p = 0.0003) but not after CTRL. In young patients with obesity, RMIT inserted in a 3-week BWRP reduced the cardiorespiratory burden, the metabolic cost, the perceived effort, and improved exercise tolerance during heavy-intensity cycling.
Collapse
|
4
|
Mancera-Soto EM, Ramos-Caballero DM, Rojas J. JA, Duque L, Chaves-Gomez S, Cristancho-Mejía E, Schmidt WFJ. Hemoglobin Mass, Blood Volume and VO2max of Trained and Untrained Children and Adolescents Living at Different Altitudes. Front Physiol 2022; 13:892247. [PMID: 35721534 PMCID: PMC9204197 DOI: 10.3389/fphys.2022.892247] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Accepted: 04/18/2022] [Indexed: 11/13/2022] Open
Abstract
Introduction: To a considerable extent, the magnitude of blood volume (BV) and hemoglobin mass (Hbmass) contribute to the maximum O2-uptake (VO2max), especially in endurance-trained athletes. However, the development of Hbmass and BV and their relationships with VO2max during childhood are unknown. The aim of the present cross-sectional study was to investigate Hbmass and BV and their relationships with VO2max in children and adolescents. In addition, the possible influence of endurance training and chronic hypoxia was evaluated.Methods: A total of 475 differently trained children and adolescents (girls n = 217, boys n = 258; untrained n = 171, endurance trained n = 304) living at two different altitudes (∼1,000 m, n = 204, ∼2,600 m, n = 271) and 9–18 years old participated in the study. The stage of puberty was determined according to Tanner; Hbmass and BV were determined by CO rebreathing; and VO2max was determined by cycle ergometry and for runners on the treadmill.Results: Before puberty, there was no association between training status and Hbmass or BV. During and after puberty, we found 7–10% higher values in the trained groups. Living at a moderate altitude had a uniformly positive effect of ∼7% on Hbmass in all groups and no effect on BV. The VO2max before, during and after puberty was strongly associated with training (pre/early puberty: boys +27%, girls +26%; mid puberty: +42% and +45%; late puberty: +43% and +47%) but not with altitude. The associated effects of training in the pre/early pubertal groups were independent of Hbmass and BV, while in the mid- and late pubertal groups, 25% of the training effect could be attributed to the elevated Hbmass.Conclusions: The associated effects of training on Hbmass and BV, resulting in increased VO2max, can only be observed after the onset of puberty.
Collapse
Affiliation(s)
- Erica Mabel Mancera-Soto
- Departamento del Movimiento Corporal Humano, Facultad de Medicina, Universidad Nacional de Colombia, Bogotá, Colombia
- Department of Sports Medicine and Sports Physiology, University of Bayreuth, Bayreuth, Germany
| | - Diana Marcela Ramos-Caballero
- Departamento de Biología, Facultad de Ciencias, Universidad Nacional de Colombia, Bogotá, Colombia
- Escuela de Medicina y Ciencias de la Salud, Universidad del Rosario, Bogotá, Colombia
| | - Joel A. Rojas J.
- Programa de Licenciatura en Educación Física Recreación y Deporte, Facultad de Ciencias de la Educación, Unidad Central del Valle del Cauca, Tuluá, Colombia
| | - Lohover Duque
- Programa de Licenciatura en Educación Física Recreación y Deporte, Facultad de Ciencias de la Educación, Unidad Central del Valle del Cauca, Tuluá, Colombia
| | - Sandra Chaves-Gomez
- Laboratorio de Control al Dopaje, Ministerio del Deporte de Colombia, Bogotá, Colombia
| | - Edgar Cristancho-Mejía
- Departamento de Biología, Facultad de Ciencias, Universidad Nacional de Colombia, Bogotá, Colombia
| | - Walter Franz-Joachim Schmidt
- Department of Sports Medicine and Sports Physiology, University of Bayreuth, Bayreuth, Germany
- *Correspondence: Walter Franz-Joachim Schmidt,
| |
Collapse
|
5
|
Schmidt WFJ, Wachsmuth N, Jimenez J, Soria R. Hemoglobin Mass and Blood Volume in Patients With Altitude-Related Polycythemia. Front Physiol 2022; 13:867108. [PMID: 35574463 PMCID: PMC9096560 DOI: 10.3389/fphys.2022.867108] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 04/06/2022] [Indexed: 11/13/2022] Open
Abstract
Patients with chronic mountain sickness (CMS) have a high hemoglobin concentration [Hb] due to increased hemoglobin mass (Hbmass) and possibly reduced plasma volume (PV). The values of Hbmass, PV and blood volume (BV) have been described differently, and the relationships between [Hb] and Hbmass or PV are poorly understood. This study obtained representative Hbmass, PV and BV data from healthy, high-altitude residents and CMS patients and quantified the dependency of [Hb] on Hbmass and PV. METHODS Eighty-seven subjects born at high altitude (∼3,900 m) were enrolled. Thirty-four had CMS (CMS), 11 had polycythemia without CMS (intermediate, IM), 20 were healthy highlanders (HH), and 22 living near sea level (SL, 420 m) served as the sea level (SL) control group. Hbmass, PV and BV were determined using a CO-rebreathing method modified for assessing polycythemia patients. Furthermore, [Hb], hematocrit (Hct), plasma erythropoietin concentration [EPO] and blood gas and acid-base status were determined. RESULTS In the HH group, Hbmass was 27% higher (940 ± 105 g) than in the SL group (740 ± 112 g) and 72% (1,617 ± 265 g) lower than in the CMS group. The PV in the HH group was similar to that in the SL group (-6%) and 15% higher than that in the CMS group (p < 0.001). In the HH group, the BV (5,936 ± 673 ml) did not differ from that in the SL group and was 28% lower than in the CMS group (7,606 ± 1075 ml, p < 0.001). Log [EPO] was slightly increased in the CMS group relative to the HH group (p < 0.01). All values in the IM group were between those in the HH and CMS groups. Hbmass and BV were positively correlated, and PV was negatively correlated with peripheral O2 saturation. Increased Hbmass and decreased PV contributed approximately 65 and 35%, respectively, to the difference in [Hb] between the HH (17.1 ± 0.8 g/dl) and CMS (22.1 ± 1.0 g/dl) groups. CONCLUSIONS In CMS patients, the decrease in PV only partially compensated for the substantial increase in Hbmass, but it did not prevent an increase in BV; the decrease in PV contributed to an excessively high [Hb].
Collapse
Affiliation(s)
- Walter F J Schmidt
- Department of Sports Medicine and Sports Physiology, University of Bayreuth, Bayreuth, Germany
| | - Nadine Wachsmuth
- Department of Sports Medicine and Sports Physiology, University of Bayreuth, Bayreuth, Germany
| | - Jesus Jimenez
- Instituto Boliviano de Biologia de Altura, Universidad Mayor de San Andres, La Paz, Bolivia
| | - Rudy Soria
- Instituto Boliviano de Biologia de Altura, Universidad Mayor de San Andres, La Paz, Bolivia
| |
Collapse
|
6
|
Costa RFD, Masset KVDSB, Silva AM, Cabral BGDAT, Dantas PMS. Development and cross-validation of predictive equations for fat-free mass and lean soft tissue mass by bioelectrical impedance in Brazilian women. Eur J Clin Nutr 2021; 76:288-296. [PMID: 34230624 DOI: 10.1038/s41430-021-00946-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Revised: 05/07/2021] [Accepted: 05/17/2021] [Indexed: 11/09/2022]
Abstract
BACKGROUND/OBJECTIVES Bioelectrical impedance is one of the most used clinical techniques to assess body composition; however, it is necessary that the available predictive equations are valid for the evaluated subjects. This study aimed to develop and cross-validate equations for fat-free mass (FFM) and lean soft tissue mass (LSTM) by bioelectrical impedance for Brazilian women, in addition to test the validity of other available equations. SUBJECTS/METHODS Cross-sectional study with 222 women aged 20-59 years, randomly divided into two groups: development and cross-validation. The standard technique for assessing fat mass, FFM and LSTM was dual energy X-ray absorptiometry. Paired t test, multiple regression, and Bland-Altman plots were used to test the validity of the proposed models, as well as to perform cross-validation of the models. RESULTS The equations derived in this study were: FFM = 16.284 + 0.442 × (Height2/Resistance) - 0.13 × age + 0.302 × Weight - 0.121 × Waist Circumference; r2 = 0.86; SEE = 2.32 kg; and LSTM = 14.732 + 0.427 × (Height2/Resistance) - 0.125 × age + 0.291 × Weight - 0.115 × Waist Circumference; r2 = 0.92; SEE = 2.29 kg. In addition, the new equation for FFM showed better agreement when compared to another equation developed for a Brazilian population. CONCLUSIONS The newly developed equations provide a valid FFM and LSTM estimation and are recommended for Brazilian women with similar characteristics.
Collapse
Affiliation(s)
- Roberto Fernandes da Costa
- Physical Education Department, Health Sciences Centre, Universidade Federal do Rio Grande do Norte, Natal, Brazil.
| | | | - Analiza M Silva
- Exercise and Health Laboratory, CIPER, Faculdade Motricidade Humana, Universidade de Lisboa, Lisbon, Portugal
| | | | - Paulo Moreira Silva Dantas
- Physical Education Department, Health Sciences Centre, Universidade Federal do Rio Grande do Norte, Natal, Brazil
| |
Collapse
|
7
|
Concordance between Body Composition Indices Measured with Dual-Energy X-Ray Absorptiometry and Bioelectrical Impedance Analysis in Obese Children in Sri Lanka. Int J Pediatr 2021; 2021:6638057. [PMID: 33628278 PMCID: PMC7896873 DOI: 10.1155/2021/6638057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 01/28/2021] [Accepted: 02/02/2021] [Indexed: 11/17/2022] Open
Abstract
Dual-energy X-ray absorptiometry (DXA) is the reference standard in the measurement of body composition indices. But, its utility is limited due to the high cost, expertise required, lack of portability, and restricted availability. Therefore, bioelectrical impedance analysis (BIA) has gained recognition in resource-limited settings for the measurement of body composition indices in the screening of children for childhood obesity. To determine whether BIA represents a viable alternative to DXA in the assessment of body composition in obese children in the community setting in Sri Lanka, the concordance between BIA and DXA was determined. Fat mass (FM), percentage fat mass (%FM), and fat-free mass (FFM) were measured in 97 obese children using DXA and BIA, and the concordance between the methods was analyzed using independent sample t-test, regression analysis, and Bland-Altman plots. Significant mean differences were observed between DXA and BIA in measuring FM and FFM. However, high correlations were seen in DXA- and BMI-derived FM and FFM measurements (FM r = 0.92 and FFM 0.83, P < 0.001 for both). Compared to DXA, BIA overestimated FM and %FM and underestimated FFM. When compared with DXA-derived measurements, the accuracy errors (SEE) of BIA for FM, FFM, and %FM were relatively higher in boys (3.56 kg, 4.49 kg, and 5.46%, respectively) than in girls (2.44 kg, 3.72 kg, and 3.5%), respectively. BA plots showed a systematic error in the measurements of FM, FFM, and %FM in both sexes. Despite the limitations inherited, BIA is a viable alternative to DXA for the measurement of body composition in obese children of 5-15 yrs. The accuracy errors observed, however, need to be taken into consideration when interpreting results at the individual level.
Collapse
|
8
|
Behling EB, Camelo Júnior JS, Ferriolli E, Pfrimer K, Monteiro JP. NUTRITIONAL STATUS IN CHILDREN WITH CANCER: COMPARISON OF DEUTERIUM OXIDE DILUTION WITH BIOELECTRIC IMPEDANCE ANALYSIS AND ANTHROPOMETRY. ACTA ACUST UNITED AC 2020; 39:e2019209. [PMID: 32756757 PMCID: PMC7401501 DOI: 10.1590/1984-0462/2021/39/2019209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2019] [Accepted: 09/22/2019] [Indexed: 11/22/2022]
Abstract
Objective: To explore changes in the nutritional status of pediatric cancer patients
before and after chemotherapy and evaluate the correlation between deuterium
oxide dilution, bioelectric impedance analysis, and anthropometry for
assessment of body composition. Methods: This study included 14 children (aged 5.6 to 13.6 years) and classified them
as having hematologic or solid tumors. They had their body composition
analyzed according to deuterium oxide, bioelectric impedance, and
anthropometric measurements before the first chemotherapy cycle and after
three and six months of therapy. Results: The patients in the hematologic tumor group had an increase in weight,
height, body mass index, waist, hip, and arm circumference, subscapular
skinfold thickness, and fat mass with the isotope dilution technique during
chemotherapy. In the solid tumor group, the children showed a reduction in
fat-free mass when assessed by bioimpedance analysis. We found a positive
correlation between the triceps skinfold thickness and fat mass determined
by bioimpedance analysis and deuterium oxide. The arm muscle circumference
correlated with the fat-free mass estimated by bioimpedance analysis and
deuterium oxide. Conclusions: Patients with hematologic tumors had an increase in body weight, height, and
fat mass, which was not identified in the solid tumor group. The positive
correlation between anthropometry (triceps skinfold thickness and arm muscle
circumference), deuterium oxide dilution, and bioelectric impedance analysis
shows the applicability of anthropometry in clinical practice.
Collapse
|
9
|
Orsso CE, Silva MIB, Gonzalez MC, Rubin DA, Heymsfield SB, Prado CM, Haqq AM. Assessment of body composition in pediatric overweight and obesity: A systematic review of the reliability and validity of common techniques. Obes Rev 2020; 21:e13041. [PMID: 32374499 DOI: 10.1111/obr.13041] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Revised: 04/05/2020] [Accepted: 04/16/2020] [Indexed: 01/13/2023]
Abstract
Accurate measurement of body composition is required to improve health outcomes in children and adolescents with overweight or obesity. This systematic review aimed to summarize the reliability and validity of field and laboratory body composition techniques employed in pediatric obesity studies to facilitate technique selection for research and clinical practice implementation. A systematic search in MEDLINE (via PubMed), EMBASE, CINAHL, and SPORTDiscus from inception up to December 2019 was conducted, using a combination of the following concepts: body composition, pediatric overweight/obesity, and reliability/validity. The search strategy resulted in 66 eligible articles reporting reliability (19.7%), agreement between body composition techniques cross sectionally (80.3%), and/or diagnostic test accuracy (10.6%) in children and adolescents with overweight or obesity (mean age range = 7.0-16.5 years). Skinfolds, air-displacement plethysmography (ADP), dual-energy X-ray absorptiometry (DXA), and ultrasound presented as reliable techniques. DXA, ADP, and isotope dilution showed similar and the best agreement with reference standards. Compared with these laboratory techniques, the validity of estimating body composition by anthropometric equations, skinfolds, and BIA was inferior. In conclusion, the assessment of body composition by laboratory techniques cannot be replaced by field techniques due to introduction of measurement errors, which potentially conceal actual changes in body components.
Collapse
Affiliation(s)
- Camila E Orsso
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada
| | - Maria Ines B Silva
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada.,Department of Applied Nutrition, Nutrition Institute, Rio de Janeiro State University, Rio de Janeiro, Brazil.,Department of Applied Nutrition, Nutrition School, Federal University of Rio de Janeiro State, Rio de Janeiro, Brazil
| | - Maria Cristina Gonzalez
- Postgraduate Program in Health and Behavior, Catholic University of Pelotas, Pelotas, Brazil.,Pennington Biomedical Research Center, LSU System, Baton Rouge, Louisiana, USA
| | - Daniela A Rubin
- Department of Kinesiology, California State University, Fullerton, California, USA
| | - Steven B Heymsfield
- Pennington Biomedical Research Center, LSU System, Baton Rouge, Louisiana, USA
| | - Carla M Prado
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada
| | - Andrea M Haqq
- Department of Agricultural, Food and Nutritional Science, University of Alberta, Edmonton, Alberta, Canada.,Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
10
|
Wong MC, Ng BK, Kennedy SF, Hwaung P, Liu EY, Kelly NN, Pagano IS, Garber AK, Chow DC, Heymsfield SB, Shepherd JA. Children and Adolescents' Anthropometrics Body Composition from 3-D Optical Surface Scans. Obesity (Silver Spring) 2019; 27:1738-1749. [PMID: 31689009 PMCID: PMC7883773 DOI: 10.1002/oby.22637] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Accepted: 06/13/2019] [Indexed: 12/13/2022]
Abstract
OBJECTIVE This study aimed to explore the accuracy and precision of three-dimensional optical (3DO) whole-body scanning for automated anthropometry and estimating total and regional body composition. METHODS Healthy children and adolescents (n = 181, ages 5-17 years) were recruited for the Shape Up! Kids study. Each participant underwent whole-body dual-energy x-ray absorptiometry and 3DO scans; multisite conventional tape measurements served as the anthropometric criterion measure. 3DO body shape was described using automated body circumference, length, and volume measures. 3DO estimates were compared with criterion measures using simple linear regression by the stepwise selection method. RESULTS Of the 181 participants, 112 were used for the training set, 49 were used for the test set, and 20 were excluded for technical reasons. 3DO body composition estimates were strongly associated with dual-energy x-ray absorptiometry measures for percent body fat, fat mass, and fat-free mass (R2 : 0.83, 0.96, and 0.98, respectively). 3DO provided reliable measurements of fat mass (coefficient of variation, 3.30; root mean square error [RMSE], 0.53), fat-free mass (coefficient of variation, 1.34; RMSE, 0.53 kg), and percent body fat (RMSE = 1.2%). CONCLUSIONS 3DO surface scanning provides accurate and precise anthropometric and body composition estimates in children and adolescents with high precision. 3DO is a safe, accessible, and practical method for evaluating body shape and composition in research and clinical settings.
Collapse
Affiliation(s)
- Michael C. Wong
- Graduate Program in Human Nutrition, University of Hawai’i Manoa, Honolulu, Hawaii, USA
- Department of Epidemiology, University of Hawai’i Cancer Center, Honolulu, Hawaii, USA
| | - Bennett K. Ng
- Department of Epidemiology, University of Hawai’i Cancer Center, Honolulu, Hawaii, USA
| | - Samantha F. Kennedy
- Pennington Biomedical Research Center, Louisiana State University, Baton Rouge, Louisiana, USA
| | - Phoenix Hwaung
- Pennington Biomedical Research Center, Louisiana State University, Baton Rouge, Louisiana, USA
| | - En Y. Liu
- Department of Epidemiology, University of Hawai’i Cancer Center, Honolulu, Hawaii, USA
| | - Nisa N. Kelly
- Department of Epidemiology, University of Hawai’i Cancer Center, Honolulu, Hawaii, USA
| | - Ian S. Pagano
- Department of Epidemiology, University of Hawai’i Cancer Center, Honolulu, Hawaii, USA
| | - Andrea K. Garber
- Division of Adolescent & Young Adult Medicine, University of California, San Francisco, California, USA
| | - Dominic C. Chow
- John A. Burns School of Medicine, University of Hawai’i, Honolulu, Hawaii, USA
| | - Steven B. Heymsfield
- Pennington Biomedical Research Center, Louisiana State University, Baton Rouge, Louisiana, USA
| | - John A. Shepherd
- Graduate Program in Human Nutrition, University of Hawai’i Manoa, Honolulu, Hawaii, USA
- Department of Epidemiology, University of Hawai’i Cancer Center, Honolulu, Hawaii, USA
| |
Collapse
|
11
|
Chu L, Steinberg A, Mehta M, O'Kane C, Toulany A, Langer JC, Hamilton JK. Resting Energy Expenditure and Metabolic Adaptation in Adolescents at 12 Months After Bariatric Surgery. J Clin Endocrinol Metab 2019; 104:2648-2656. [PMID: 30753542 DOI: 10.1210/jc.2018-02244] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Accepted: 02/06/2019] [Indexed: 02/04/2023]
Abstract
BACKGROUND Evidence suggests that metabolic adaptation occurs after bariatric surgery such that resting energy expenditure (REE) declines more than accounted for by body weight or body composition changes in adults. Little is known about REE and metabolic adaptation among adolescents after bariatric surgery. OBJECTIVE To examine changes in REE and metabolic adaptation among adolescents at 12 months (12M) after bariatric surgery. SETTING Pediatric hospital, Canada. METHODS Adolescents undergoing Roux-en-Y gastric bypass (RYGB) or sleeve gastrectomy (SG) were followed. Bioelectrical impedance analysis and indirect calorimetry were completed to measure body composition and REE, respectively. Predicted REE was calculated using the Mifflin equation before and after bariatric surgery and a predictive equation using preoperative data. RESULTS Among 20 patients (15 girls), the mean age and body mass index at surgery were 17.2 ± 0.8 years and 48.7 ± 7.4 kg/m2, respectively. REE had decreased by 548.3 kcal/d at 12M postoperatively (P < 0.001). Metabolic adaptation, determined by two procedures, was negative and significantly different from baseline (P < 0.05). When stratified by surgery type, REE change at 12M was not significantly different (RYGB, -494.0 ± 260.9 kcal/d, n = 11; SG, -614.6 ± 344.4 kcal/d, n = 9; P = 0.384). Among 13 patients with REE data at 6 and 12M, no statistically significant difference was found (P = 0.368). CONCLUSIONS Predicted and measured REE was 19% and 25% lower at 12M, respectively, irrespective of bariatric surgery type. Metabolic adaptation might predispose adolescents to weight regain after bariatric surgery and warrants careful nutritional management and counseling.
Collapse
Affiliation(s)
- Lisa Chu
- SickKids Team Obesity Management Program, Division of Endocrinology, The Hospital for Sick Children, Toronto, Ontario, Canada
- Department of Paediatrics, University of Toronto, Toronto, Ontario, Canada
| | - Alissa Steinberg
- SickKids Team Obesity Management Program, Division of Endocrinology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Michael Mehta
- SickKids Team Obesity Management Program, Division of Endocrinology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Carley O'Kane
- SickKids Team Obesity Management Program, Division of Endocrinology, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Alene Toulany
- Department of Paediatrics, University of Toronto, Toronto, Ontario, Canada
- Division of Adolescent Medicine, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Jacob C Langer
- Department of Surgery, University of Toronto, Toronto, Ontario, Canada
- Division of General and Thoracic Surgery, The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Jill K Hamilton
- SickKids Team Obesity Management Program, Division of Endocrinology, The Hospital for Sick Children, Toronto, Ontario, Canada
- Department of Paediatrics, University of Toronto, Toronto, Ontario, Canada
| |
Collapse
|
12
|
Cossio Bolaños MA, Andruske CL, de Arruda M, Sulla-Torres J, Urra-Albornoz C, Rivera-Portugal M, Luarte-Rocha C, Pacheco-Carrillo J, Gómez-Campos R. Muscle Mass in Children and Adolescents: Proposed Equations and Reference Values for Assessment. Front Endocrinol (Lausanne) 2019; 10:583. [PMID: 31555209 PMCID: PMC6722176 DOI: 10.3389/fendo.2019.00583] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Accepted: 08/09/2019] [Indexed: 12/25/2022] Open
Abstract
Objectives: The goal of this study was to develop regression equations to estimate LM with anthropometric variables and to propose percentiles for evaluating by age and sex. Methods: A cross sectional study was conducted with 2,182 Chilean students (1,347 males and 835 females). Ages ranged from 5.0 to 17.9 years old. A total body scan was carried out with the double energy X-ray anthropometry (DXA) to examine and measure lean muscle mass of the entire body. Weight, height, and the circumference of the relaxed right arm were also measured. Results: Four anthropometric equations were generated to predict lean mass for both sexes (R 2 = 83-88%, SEE = 3.7-5.0%, precision = 0.90-0.93, and accuracy = 0.99). The Lambda-mu-sigma method was used to obtain the sex-specific and age-specific percentile curves of lean mass (p3, p5, p10, p15, p25, p50, p75, p85, p90, p95, and p97). Conclusion: The four proposed equations were acceptable in terms of precision and accuracy to estimate lean mass in children and adolescents. The percentiles were created by means of anthropometric equations and real values for DXA. These are fundamental tools for monitoring LM in Chilean children and adolescents of both sexes.
Collapse
Affiliation(s)
- Marco A. Cossio Bolaños
- Programa de Doctorado en Ciencias de la Actividad Física, Universidad Católica del Maule, Talca, Chile
- *Correspondence: Marco A. Cossio Bolaños
| | | | - Miguel de Arruda
- Faculty of Physical Education, State University of Campinas, Campinas, Brazil
| | | | - Camilo Urra-Albornoz
- Escuela de Kinesiología, Facultad de Salud, Universidad Santo Tomás, Talca, Chile
| | | | | | | | - Rossana Gómez-Campos
- Departamento de Diversidad e Inclusividad Educativa, Universidad Católica del Maule, Talca, Chile
- Rossana Gómez-Campos
| |
Collapse
|
13
|
Ndagire CT, Muyonga JH, Odur B, Nakimbugwe D. Prediction equations for body composition of children and adolescents aged 8-19 years in Uganda using deuterium dilution as the reference technique. Clin Nutr ESPEN 2018; 28:103-109. [PMID: 30390864 DOI: 10.1016/j.clnesp.2018.09.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Accepted: 09/11/2018] [Indexed: 01/27/2023]
Abstract
BACKGROUND AND AIMS Body composition is important as a marker of both current and future health status. Bioelectrical impedance analysis (BIA) is a simple and accurate method for estimating body composition in field, clinical and research settings, if standard protocol procedures are followed. However, BIA requires population-specific equations since applicability of existing equations to diverse populations has been questioned. This study aimed to derive predictive equations for Total Body Water (TBW), Fat Free Mass (FFM) and Fat Mass (FM) determinations with BIA and anthropometric measurements in a population of children and adolescents aged 8-19 years in Uganda. METHODS A cross-sectional study was conducted among 203 children and adolescents aged 8-19 years attending schools in Kampala district (also referred to as Kampala city since the city is conterminous with the district), Uganda through a two-stage cluster sample design. Deuterium dilution method (DDM) was used as the reference measure while BIA and anthropometric measures were used to create the new body composition prediction equations through multivariate regression. RESULTS The new prediction equations explained 88%, 87% and 71% of the variance in TBW, FFM % and of FM respectively with no statistical shrinkage upon cross-validation. The linear regression models proposed in this study were well adjusted with respect to TBW, FFM and FM. Log of TBW obtained by DDM = 0.0129 × Impedance index + 0.0055 × Age + 0.0049 Waist Circumference + 0.1219Ht2 + 2.0388. Log of FFM obtained by DDM = 0.0197 × FFM obtained by BIA - 0.0181 sex code - 0.00055 × Impedance + 3.1761. Log of FM obtained by DDM = 0.0634 × FM obtained by BIA - 0.1881 sex code + 0.0252 × Weight + 0.5273. CONCLUSION The use of these equations for more accurate body composition assessment may facilitate identification of effective intervention strategies to prevent or combat overweight and obesity among children and adolescents. They may also assist in treatment of conditions where more accurate information on body composition measures is required.
Collapse
Affiliation(s)
- Catherine T Ndagire
- Department of Food Technology and Nutrition, Makerere University, P.O. Box 7062, Kampala, Uganda.
| | - John H Muyonga
- Department of Food Technology and Nutrition, Makerere University, P.O. Box 7062, Kampala, Uganda
| | - Benard Odur
- Department of Statistical Methods and Actuarial Science, School of Statistics, Makerere University, P.O. Box 7062, Kampala, Uganda
| | - Dorothy Nakimbugwe
- Department of Food Technology and Nutrition, Makerere University, P.O. Box 7062, Kampala, Uganda
| |
Collapse
|
14
|
Ndahimana D, Choi YJ, Park JH, Ju MJ, Kim EK. Validity of predictive equations for resting energy expenditure in Korean non-obese adults. Nutr Res Pract 2018; 12:283-290. [PMID: 30090165 PMCID: PMC6078867 DOI: 10.4162/nrp.2018.12.4.283] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2018] [Revised: 02/08/2018] [Accepted: 03/26/2018] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND/OBJECTIVES Indirect calorimetry is the gold-standard method for the measurement of resting energy expenditure. However, this method is time consuming, expensive, and requires highly trained personnel. To overcome these limitations, various predictive equations have been developed. The objective of this study was to assess the validity of predictive equations for resting energy expenditure (REE) in Korean non-obese adults. SUBJECTS/METHODS The present study involved 109 participants (54 men and 55 women) aged between 20 and 64 years. The REE was measured by indirect calorimetry. Nineteen REE equations were evaluated for validity, by comparing predicted and measured REE results. Predictive equation accuracy was assessed by determining percent bias, root mean squared prediction error (RMSE), and percentage of accurate predictions. RESULTS The measured REE was significantly higher in men than in women (P < 0.001), but the difference was not significant after adjusting for body weight (P > 0.05). The equation developed in this study had an accuracy rate of 71%, a bias of 0%, and an RMSE of 155 kcal/day. Among published equations, the FAOweight equation gave the highest accuracy rate (70%), along with a bias of -4.4% and an RMSE of 184 kcal/day. CONCLUSIONS The newly developed equation provided the best accuracy in predicting REE for Korean non-obese adults. Among the previously published equations, the FAOweight equation showed the highest overall accuracy. Regardless, at an individual level, the equations could lead to inaccuracies in a considerable number of subjects.
Collapse
Affiliation(s)
- Didace Ndahimana
- Department of Food and Nutrition, Gangneung-Wonju National University, 7 Jukheon-gil, Gangneung, Gangwon 25457, Korea
| | - Yeon-Jung Choi
- Department of Food and Nutrition, Gangneung-Wonju National University, 7 Jukheon-gil, Gangneung, Gangwon 25457, Korea
| | - Jung-Hye Park
- Department of Food and Nutrition, Gangneung-Wonju National University, 7 Jukheon-gil, Gangneung, Gangwon 25457, Korea
| | - Mun-Jeong Ju
- Department of Food and Nutrition, Gangneung-Wonju National University, 7 Jukheon-gil, Gangneung, Gangwon 25457, Korea
| | - Eun-Kyung Kim
- Department of Food and Nutrition, Gangneung-Wonju National University, 7 Jukheon-gil, Gangneung, Gangwon 25457, Korea
| |
Collapse
|
15
|
Girsh YV, Gerasimchik OA. The role and place of bioimpedance analysis assessment of body composition of children and adolescents with different body mass. BULLETIN OF SIBERIAN MEDICINE 2018. [DOI: 10.20538/1682-0363-2018-2-121-132] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The steady rise of obesity in children and adolescents emphasizes the need for new, integrated approaches to its diagnosis and therapy. When diagnosing obesity and choosing methods for its correction, it is fundamentally important to use reliable methods of estimating the amount of adipose tissue. Using the body mass index is not always sufficient, since it does not provide complete information on quantitative content in the body weight of the patient’s body. For these purposes in clinical medicine use of bioimpedance analysis to assess the indicators, which characterize the basal metabolism, active cell mass, fat and basirova mass and total water content in the body. However, the holding of bioimpedance body composition analysis is currently limited mainly to dietetics and sports medicine, and adult patients. Quite interesting is the use of the bioimpedance method in the pediatric age group for accurate evaluation of body composition of children of various ages and body weight that will allow for dynamic control of all types of metabolism to evaluate the effectiveness of the observation and treatment of patients with overweight and obesity.
Collapse
|
16
|
Seo YG, Kim JH, Kim Y, Lim H, Ju YS, Kang MJ, Lee K, Lee HJ, Jang HB, Park SI, Park KH. Validation of body composition using bioelectrical impedance analysis in children according to the degree of obesity. Scand J Med Sci Sports 2018; 28:2207-2215. [DOI: 10.1111/sms.13248] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2018] [Accepted: 06/20/2018] [Indexed: 12/01/2022]
Affiliation(s)
- Young-Gyun Seo
- Department of Family Medicine; Hallym University Sacred Heart Hospital; Anyang Korea
| | - Jae Hyun Kim
- Department of Pediatrics; Seoul National University Bundang Hospital; Seongnam Korea
| | - YoonMyung Kim
- University College; Yonsei University International Campus; Incheon Korea
| | - Hyunjung Lim
- Department of Medical Nutrition; Kyung Hee University; Yongin Korea
| | - Young-Su Ju
- Department of Occupational and Environmental Medicine; Hallym University Sacred Heart Hospital; Anyang Korea
| | - Min Jae Kang
- Department of Pediatrics; Hallym University Sacred Heart Hospital; Anyang Korea
| | - Kwanseop Lee
- Department of Radiology; Hallym University Sacred Heart Hospital; Anyang Korea
| | - Hye-Ja Lee
- Center for Biomedical Sciences; Korea National Institute of Health; Cheongju Korea
| | - Han Byul Jang
- Center for Biomedical Sciences; Korea National Institute of Health; Cheongju Korea
| | - Sang Ick Park
- Center for Biomedical Sciences; Korea National Institute of Health; Cheongju Korea
| | - Kyung Hee Park
- Department of Family Medicine; Hallym University Sacred Heart Hospital; Anyang Korea
| |
Collapse
|
17
|
Yang EM, Park E, Ahn YH, Choi HJ, Kang HG, Cheong HI, Ha IS. Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis. J Korean Med Sci 2017; 32:1828-1834. [PMID: 28960036 PMCID: PMC5639064 DOI: 10.3346/jkms.2017.32.11.1828] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 08/19/2017] [Indexed: 01/04/2023] Open
Abstract
Adequate fluid management is an important therapeutic goal of dialysis. Recently, bioelectrical impedance methods have been used to determine body fluid status, but pediatric reports are rare. To determine the accuracy of bioelectrical impedance methods in the assessment of body fluid statusof children undergoing hemodialysis (HD), 12 children on HD were studied. A multi-frequency bioimpedance analysis device (Inbody S10) and bioimpedance spectroscopy device (BCM) were used to evaluate fluid status. Fluid removal during a HD session (assessed as body-weight change, ΔBWt) was compared with the difference in total body water determined by each device (measured fluid difference, ΔMF), which showed strong correlation using either method (Pearson's coefficient, r = 0.772 with Inbody S10 vs. 0.799 with BCM). Bioimpedance measurement indicated fluid overload (FO; ΔHS greater than 7%) in 34.8% with Inbody S10 and 56.5% with BCM, and only about 60% of children with FO by bioimpedance methods showed clinical symptoms such as hypertension and edema. In some patients with larger weight gain Inbody S10-assessed overhydration (OH) was much smaller than BCM-assessed OH, suggesting that BCM is more relevant in estimating fluid accumulation amount than Inbody S10. To our knowledge, this is the first report on the use of body composition monitors to assess fluid status in Korean children receiving HD.
Collapse
Affiliation(s)
- Eun Mi Yang
- Department of Pediatrics, Chonnam National University Hospital, Gwangju, Korea
| | - Eujin Park
- Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Yo Han Ahn
- Department of Pediatrics, Hallym University Kangnam Sacred Heart Hospital, Seoul, Korea
| | - Hyun Jin Choi
- Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Hee Gyung Kang
- Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea.
| | - Hae Il Cheong
- Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea
| | - Il Soo Ha
- Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
18
|
Salvadego D, Sartorio A, Agosti F, Tringali G, Patrizi A, Isola M, LoMauro A, Aliverti A, Grassi B. Respiratory muscle endurance training reduces the O2 cost of cycling and perceived exertion in obese adolescents. Am J Physiol Regul Integr Comp Physiol 2017; 313:R487-R495. [DOI: 10.1152/ajpregu.00396.2016] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2016] [Revised: 07/17/2017] [Accepted: 07/17/2017] [Indexed: 11/22/2022]
Abstract
In obesity, the increased O2 cost of breathing negatively affects the O2 cost of exercise and exercise tolerance. The purpose of the study was to determine whether, in obese adolescents, the addition of respiratory muscle endurance training (RMET) (isocapnic hyperpnea) to a standard body mass reduction program decreases the O2 cost of exercise and perceived exertion. Nine male obese adolescents [16.0 ± 1.4 yr ( x ± SD), body mass 114.4 ± 22.3 kg] underwent 3 wk of RMET (5 days/week) in addition to a standard body mass reduction program. Eight age- and sex-matched obese adolescents underwent only the standard program (CTRL). Before and after interventions, patients performed on a cycle ergometer: incremental exercise; 12-min exercises at a constant work rate (CWR) of 65% and 120% at the gas exchange threshold (GET) determined before the intervention. Breath-by-breath pulmonary ventilation (V̇e) and O2 uptake (V̇o2), heart rate (HR), and ratings of perceived exertion for dyspnea/respiratory discomfort (RPER) and leg effort (RPEL) were determined. Body mass decreased (by ~3.0 kg) after both RMET ( P = 0.003) and CTRL ( P = 0.002). Peak V̇o2 was not affected by both interventions. Peak work rate was slightly, but significantly ( P = 0.04), greater after RMET but not after CTRL. During CWR < GET, no changes were observed after both interventions. During CWR > GET, the O2 cost of cycling at the end of exercise ( P = 0.02), the slope of V̇o2 vs. time (3–12 min) ( P = 0.01), RPER ( P = 0.01), and RPEL ( P = 0.01) decreased following RMET, but not following CTRL. HR decreased after both RMET ( P = 0.02) and CTRL ( P = 0.03), whereas V̇e did not change. In obese adolescents RMET, superimposed on a standard body mass reduction program, lowered the O2 cost of cycling and perceived exertion during constant heavy-intensity exercise.
Collapse
Affiliation(s)
- Desy Salvadego
- Department of Medicine, University of Udine, Udine, Italy
| | - Alessandro Sartorio
- Istituto Auxologico Italiano, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS), Division of Metabolic Diseases and Auxology, Piancavallo, Italy
- Istituto Auxologico Italiano, IRCCS, Experimental Laboratory for Auxo-Endocrinological Research, Milan and Piancavallo, Italy
| | - Fiorenza Agosti
- Istituto Auxologico Italiano, IRCCS, Experimental Laboratory for Auxo-Endocrinological Research, Milan and Piancavallo, Italy
| | - Gabriella Tringali
- Istituto Auxologico Italiano, IRCCS, Experimental Laboratory for Auxo-Endocrinological Research, Milan and Piancavallo, Italy
| | - Alessandra Patrizi
- Istituto Auxologico Italiano, IRCCS, Experimental Laboratory for Auxo-Endocrinological Research, Milan and Piancavallo, Italy
| | - Miriam Isola
- Department of Medicine, University of Udine, Udine, Italy
| | - Antonella LoMauro
- Department of Electronics, Information and Bioengineering, Politecnico, Milan, Italy; and
| | - Andrea Aliverti
- Department of Electronics, Information and Bioengineering, Politecnico, Milan, Italy; and
| | - Bruno Grassi
- Department of Medicine, University of Udine, Udine, Italy
- Institute of Bioimaging and Molecular Physiology, National Research Council, Milan, Italy
| |
Collapse
|