1
|
Prajapati M, Vishwanath K, Huang L, Colville M, Reesink H, Paszek M, Bonassar LJ. Specific Degradation of the Mucin Domain of Lubricin in Synovial Fluid Impairs Cartilage Lubrication. ACS Biomater Sci Eng 2024. [PMID: 39425698 DOI: 10.1021/acsbiomaterials.4c00908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2024]
Abstract
Progressive cartilage degradation, synovial inflammation, and joint lubrication dysfunction are key markers of osteoarthritis. The composition of synovial fluid (SF) is altered in OA, with changes to both hyaluronic acid and lubricin, the primary lubricating molecules in SF. Lubricin's distinct bottlebrush mucin domain has been speculated to contribute to its lubricating ability, but the relationship between its structure and mechanical function in SF is not well understood. Here, we demonstrate the application of a novel mucinase (StcE) to selectively degrade lubricin's mucin domain in SF to measure its impact on joint lubrication and friction. Notably, StcE effectively degraded the lubricating ability of SF in a dose-dependent manner starting at nanogram concentrations (1-3.2 ng/mL). Further, the highest StcE doses effectively degraded lubrication to levels on par with trypsin, suggesting that cleavage at the mucin domain of lubricin is sufficient to completely inhibit the lubrication mechanism of the collective protein component in SF. These findings demonstrate the value of mucin-specific experimental approaches to characterize the lubricating properties of SF and reveal key trends in joint lubrication that help us better understand cartilage function in lubrication-deficient joints.
Collapse
Affiliation(s)
- Megh Prajapati
- Meinig School of Biomedical Engineering, Cornell University, 273 Tower Road, Ithaca, New York 14850, United States
| | - Karan Vishwanath
- Department of Materials Science and Engineering, Cornell University, 210 Bard Hall, Ithaca, New York 14853, United States
| | - Lingting Huang
- Robert Frederick Smith School of Chemical and Biomolecular Engineering, Cornell University, 113 Ho Plaza, Ithaca, New York 14853, United States
| | - Marshall Colville
- Robert Frederick Smith School of Chemical and Biomolecular Engineering, Cornell University, 113 Ho Plaza, Ithaca, New York 14853, United States
- Dept. of Clinical Sciences, College of Veterinary Medicine, Cornell University, 602 Toward Road, Ithaca, New York 14853, United States
| | - Heidi Reesink
- Dept. of Clinical Sciences, College of Veterinary Medicine, Cornell University, 602 Toward Road, Ithaca, New York 14853, United States
| | - Matthew Paszek
- Robert Frederick Smith School of Chemical and Biomolecular Engineering, Cornell University, 113 Ho Plaza, Ithaca, New York 14853, United States
| | - Lawrence J Bonassar
- Meinig School of Biomedical Engineering, Cornell University, 273 Tower Road, Ithaca, New York 14850, United States
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, 124 Hoy Road, Ithaca, New York 14850, United States
| |
Collapse
|
2
|
Du C, Chen Z, Liu S, Liu J, Zhan J, Zou J, Liao J, Huang W, Lei Y. Lubricin-Inspired Nanozymes Reconstruct Cartilage Lubrication System with an "In-Out" Strategy. SMALL METHODS 2024; 8:e2400757. [PMID: 38962862 DOI: 10.1002/smtd.202400757] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Revised: 06/25/2024] [Indexed: 07/05/2024]
Abstract
Lubricin, secreted primarily by chondrocytes, plays a critical role in maintaining the function of the cartilage lubrication system. However, both external factors such as friction and internal factors like oxidative stress can disrupt this system, leading to osteoarthritis. Inspired by lubricin, a lubricating nanozyme, that is, Poly-2-acrylamide-2-methylpropanesulfonic acid sodium salt-grafted aminofullerene, is developed to restore the cartilage lubrication system using an "In-Out" strategy. The "Out" aspect involves reducing friction through a combination of hydration lubrication and ball-bearing lubrication. Simultaneously, the "In" aspect aims to mitigate oxidative stress by reducing free radical, increasing autophagy, and improving the mitochondrial respiratory chain. This results in reduced chondrocyte senescence and increased lubricin production, enhancing the natural lubrication ability of cartilage. Transcriptome sequencing and Western blot results demonstrate that it enhances the functionality of mitochondrial respiratory chain complexes I, III, and V, thereby improving mitochondrial function in chondrocytes. In vitro and in vivo experiments show that the lubricating nanozymes reduce cartilage wear, improve chondrocyte senescence, and mitigate oxidative stress damage, thereby mitigating the progression of osteoarthritis. These findings provide novel insights into treating diseases associated with oxidative stress and frictional damage, such as osteoarthritis, and set the stage for future research and development of therapeutic interventions.
Collapse
Affiliation(s)
- Chengcheng Du
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Zhuolin Chen
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Senrui Liu
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Jiacheng Liu
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Jingdi Zhan
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Jing Zou
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Junyi Liao
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Wei Huang
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| | - Yiting Lei
- Department of Orthopedics, Orthopedic Laboratory of Chongqing Medical University, The First Affiliated Hospital of Chongqing Medical University, Chongqing, 400016, China
| |
Collapse
|
3
|
DeMoya CD, Joenathan A, Lawson TB, Felson DT, Schaer TP, Bais M, Albro MB, Mäkelä J, Snyder BD, Grinstaff MW. Advances in viscosupplementation and tribosupplementation for early-stage osteoarthritis therapy. Nat Rev Rheumatol 2024; 20:432-451. [PMID: 38858605 PMCID: PMC11348290 DOI: 10.1038/s41584-024-01125-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/10/2024] [Indexed: 06/12/2024]
Abstract
Joint kinematic instability, arising from congenital or acquired musculoskeletal pathoanatomy or from imbalances in anabolism and catabolism induced by pathophysiological factors, leads to deterioration of the composition, structure and function of cartilage and, ultimately, progression to osteoarthritis (OA). Alongside articular cartilage degeneration, synovial fluid lubricity decreases in OA owing to a reduction in the concentration and molecular weight of hyaluronic acid and surface-active mucinous glycoproteins that form a lubricating film over the articulating joint surfaces. Minimizing friction between articulating joint surfaces by lubrication is fundamental for decreasing hyaline cartilage wear and for maintaining the function of synovial joints. Augmentation with highly viscous supplements (that is, viscosupplementation) offers one approach to re-establishing the rheological and tribological properties of synovial fluid in OA. However, this approach has varied clinical outcomes owing to limited intra-articular residence time and ineffective mechanisms of chondroprotection. This Review discusses normal hyaline cartilage function and lubrication and examines the advantages and disadvantages of various strategies for restoring normal joint lubrication. These strategies include contemporary viscosupplements that contain antioxidants, anti-inflammatory drugs or platelet-rich plasma and new synthetic synovial fluid additives and cartilage matrix enhancers. Advanced biomimetic tribosupplements offer promise for mitigating cartilage wear, restoring joint function and, ultimately, improving patient care.
Collapse
Affiliation(s)
- Christian D DeMoya
- Department of Biomedical Engineering, Boston University, Boston, MA, USA
| | - Anisha Joenathan
- Division of Materials Science and Engineering, Boston University, Boston, MA, USA
| | - Taylor B Lawson
- Department of Mechanical Engineering, Boston University, Boston, MA, USA
| | - David T Felson
- Section of Rheumatology, Department of Medicine, Boston University Chobanian & Avedisian School of Medicine, Boston, USA
| | - Thomas P Schaer
- PENN VET Institute for Medical Translation, University of Pennsylvania School of Veterinary Medicine New Bolton Center, Kennett Square, PA, USA
| | - Manish Bais
- Boston University, Henry M. Goldman School of Dental Medicine, Boston, MA, USA
| | - Michael B Albro
- Department of Mechanical Engineering, Boston University, Boston, MA, USA
| | - Janne Mäkelä
- Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
| | - Brian D Snyder
- Department of Orthopaedic Surgery, Boston Children's Hospital Boston, Boston, MA, USA.
| | - Mark W Grinstaff
- Department of Biomedical Engineering, Boston University, Boston, MA, USA.
- Division of Materials Science and Engineering, Boston University, Boston, MA, USA.
- Department of Chemistry, Boston University, Boston, MA, USA.
| |
Collapse
|
4
|
Martin-Alarcon L, Govedarica A, Ewoldt RH, Bryant SL, Jay GD, Schmidt TA, Trifkovic M. Scale-Dependent Rheology of Synovial Fluid Lubricating Macromolecules. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2306207. [PMID: 38161247 DOI: 10.1002/smll.202306207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Revised: 11/20/2023] [Indexed: 01/03/2024]
Abstract
Synovial fluid (SF) is the complex biofluid that facilitates the exceptional lubrication of articular cartilage in joints. Its primary lubricating macromolecules, the linear polysaccharide hyaluronic acid (HA) and the mucin-like glycoprotein proteoglycan 4 (PRG4 or lubricin), interact synergistically to reduce boundary friction. However, the precise manner in which these molecules influence the rheological properties of SF remains unclear. This study aimed to elucidate this by employing confocal microscopy and multiscale rheometry to examine the microstructure and rheology of solutions containing recombinant human PRG4 (rhPRG4) and HA. Contrary to previous assumptions of an extensive HA-rhPRG4 network, it is discovered that rhPRG4 primarily forms stiff, gel-like aggregates. The properties of these aggregates, including their size and stiffness, are found to be influenced by the viscoelastic characteristics of the surrounding HA matrix. Consequently, the rheology of this system is not governed by a single length scale, but instead responds as a disordered, hierarchical network with solid-like rhPRG4 aggregates distributed throughout the continuous HA phase. These findings provide new insights into the biomechanical function of PRG4 in cartilage lubrication and may have implications in the development of HA-based therapies for joint diseases like osteoarthritis.
Collapse
Affiliation(s)
- Leonardo Martin-Alarcon
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Aleksandra Govedarica
- Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Randy H Ewoldt
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Steven L Bryant
- Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Gregory D Jay
- Department of Emergency Medicine - Warren Alpert Medical School & School of Engineering, Brown University, Providence, RI, 02912, USA
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, CT, 06030, USA
| | - Milana Trifkovic
- Department of Chemical and Petroleum Engineering, University of Calgary, Calgary, AB, T2N 1N4, Canada
| |
Collapse
|
5
|
Qadri MM. Targeting CD44 Receptor Pathways in Degenerative Joint Diseases: Involvement of Proteoglycan-4 (PRG4). Pharmaceuticals (Basel) 2023; 16:1425. [PMID: 37895896 PMCID: PMC10609794 DOI: 10.3390/ph16101425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 10/02/2023] [Accepted: 10/05/2023] [Indexed: 10/29/2023] Open
Abstract
Rheumatoid arthritis (RA), osteoarthritis (OA), and gout are the most prevalent degenerative joint diseases (DJDs). The pathogenesis underlying joint disease in DJDs remains unclear. Considering the severe toxicities reported with anti-inflammatory and disease-modifying agents, there is a clear need to develop new treatments that are specific in their effect while not being associated with significant toxicities. A key feature in the development of joint disease is the overexpression of adhesion molecules, e.g., CD44. Expression of CD44 and its variants in the synovial tissues of patients with DJDs is strongly associated with cartilage damage and appears to be a predicting factor of synovial inflammation in DJDs. Targeting CD44 and its downstream signaling proteins has emerged as a promising therapeutic strategy. PRG4 is a mucinous glycoprotein that binds to the CD44 receptor and is physiologically involved in joint lubrication. PRG4-CD44 is a pivotal regulator of synovial lining cell hemostasis in the joint, where lack of PRG4 expression triggers chronic inflammation and fibrosis, driven by persistent activation of synovial cells. In view of the significance of CD44 in DJD pathogenesis and the potential biological role for PRG4, this review aims to summarize the involvement of PRG4-CD44 signaling in controlling synovitis, synovial hypertrophy, and tissue fibrosis in DJDs.
Collapse
Affiliation(s)
- Marwa M. Qadri
- Department of Pharmacology and Toxicology, College of Pharmacy, Jazan University, Jazan 45142, Saudi Arabia;
- Inflammation Pharmacology and Drug Discovery Unit, Medical Research Center (MRC), Jazan University, Jazan 45142, Saudi Arabia
| |
Collapse
|
6
|
Menon NG, Tanguay AP, Zhou L, Zhang LX, Bobst CE, Han M, Ghosh M, Greene GW, Deymier A, Sullivan BD, Chen Y, Jay GD, Schmidt TA. A structural and functional comparison between two recombinant human lubricin proteins: Recombinant human proteoglycan-4 (rhPRG4) vs ECF843. Exp Eye Res 2023; 235:109643. [PMID: 37678729 PMCID: PMC10691279 DOI: 10.1016/j.exer.2023.109643] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 08/22/2023] [Accepted: 09/04/2023] [Indexed: 09/09/2023]
Abstract
Proteoglycan 4 (PRG4, lubricin) is a mucin-like glycoprotein present on the ocular surface that has both boundary lubricating and anti-inflammatory properties. Full-length recombinant human PRG4 (rhPRG4) has been shown to be clinically effective in improving signs and symptoms of dry eye disease (DED). In vitro, rhPRG4 has been shown to reduce inflammation-induced cytokine production and NFκB activity in corneal epithelial cells, as well as to bind to and inhibit MMP-9 activity. A different form of recombinant human lubricin (ECF843), produced from the same cell line as rhPRG4 but manufactured using a different process, was recently assessed in a DED clinical trial. However, ECF843 did not significantly improve signs or symptoms of DED compared to vehicle. Initial published characterization of ECF843 showed it had a smaller hydrodynamic diameter and was less negatively charged than native PRG4. Further examination of the structural and functional properties of ECF843 and rhPRG4 could contribute to the understanding of what led to their disparate clinical efficacy. Therefore, the objective of this study was to characterize and compare rhPRG4 and ECF843 in vitro, both biophysically and functionally. Hydrodynamic diameter and charge were measured by dynamic light scattering (DLS) and zeta potential, respectively. Size and molecular weight was determined for individual species by size exclusion chromatography (SEC) with in-line DLS and multi-angle light scattering (MALS). Bond structure was measured by Raman spectroscopy, and sedimentation properties were measured by analytical ultracentrifugation (AUC). Functionally, MMP-9 inhibition was measured using a commercial MMP-9 activity kit, coefficient of friction was measured using an established boundary lubrication test at a latex-glass interface, and collagen 1-binding ability was measured by quart crystal microbalance with dissipation (QCMD). Additionally, the ability of rhPRG4 and ECF843 to inhibit urate acid crystal formation and cell adhesion was assessed. ECF843 had a significantly smaller hydrodynamic diameter and was less negatively charged than rhPRG4, as assessed by DLS and zeta potential. Size was further explored with SEC-DLS-MALS, which indicated that while rhPRG4 had 3 main peaks, corresponding to monomer, dimer, and multimer as expected, ECF843 had 2 peaks that were similar in size and molecular weight compared to rhPRG4's monomer peak and a third peak that was significantly smaller in both size and molar mass than the corresponding peak of rhPRG4. Raman spectroscopy demonstrated that ECF843 had significantly more disulfide bonds, which are functionally determinant structures, relative to the carbon-carbon backbone compared to rhPRG4, and AUC indicated that ECF843 was more compact than rhPRG4. Functionally, ECF843 was significantly less effective at inhibiting MMP-9 activity and functioning as a boundary lubricant compared to rhPRG4, as well as being slower to bind to collagen 1. Additionally, ECF843 was significantly less effective at inhibiting urate acid crystal formation and at preventing cell adhesion. Collectively, these data demonstrate ECF843 and rhPRG4 are significantly different in both structure and function. Given that a protein's structure sets the foundation for its interactions with other molecules and tissues in vivo, which ultimately determine its function, these differences most likely contributed to the disparate DED clinical trial results.
Collapse
Affiliation(s)
- Nikhil G Menon
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Adam P Tanguay
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | - Libo Zhou
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA
| | - Ling X Zhang
- Emergency Medicine, Brown University, Providence, RI, USA
| | - Cedric E Bobst
- Department of Chemistry, University of Massachusetts Amherst, Amherst, MA, USA
| | - Mingyu Han
- Institute for Frontier Materials and ARC Centre of Excellence for Electromaterials Science, Deakin University, Melbourne, Victoria, Australia; Commonwealth Scientific and Industrial Research Organization (CSIRO), Agriculture and Food, Werribee, Victoria, Australia
| | - Mallika Ghosh
- Department of Cell Biology, School of Medicine, UConn Health, Farmington, CT, USA
| | - George W Greene
- Institute for Frontier Materials and ARC Centre of Excellence for Electromaterials Science, Deakin University, Melbourne, Victoria, Australia; Department of Chemistry and Biochemistry, La Trobe Institute for Molecular Science, La Trobe University, Melbourne, Australia
| | - Alix Deymier
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA
| | | | - Yupeng Chen
- Biomedical Engineering Department, University of Connecticut, Storrs, CT, USA
| | - Gregory D Jay
- Emergency Medicine, Brown University, Providence, RI, USA
| | - Tannin A Schmidt
- Biomedical Engineering Department, School of Dental Medicine, UConn Health, Farmington, CT, USA.
| |
Collapse
|
7
|
Pendyala M, Woods PS, Brubaker DK, Blaber EA, Schmidt TA, Chan DD. Endogenous production of hyaluronan, PRG4, and cytokines is sensitive to cyclic loading in synoviocytes. PLoS One 2022; 17:e0267921. [PMID: 36576921 PMCID: PMC9797074 DOI: 10.1371/journal.pone.0267921] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2022] [Accepted: 12/09/2022] [Indexed: 12/29/2022] Open
Abstract
Synovial fluid is composed of hyaluronan and proteoglycan-4 (PRG4 or lubricin), which work synergistically to maintain joint lubrication. In diseases like osteoarthritis, hyaluronan and PRG4 concentrations can be altered, resulting in lowered synovial fluid viscosity, and pro-inflammatory cytokine concentrations within the synovial fluid increase. Synovial fibroblasts within the synovium are responsible for contributing to synovial fluid and can be targeted to improve endogenous production of hyaluronan and PRG4 and to alter the cytokine profile. We cyclically loaded SW982 synoviocytes to 0%, 5%, 10%, or 20% strain for three hours at 1 Hz. To assess the impact of substrate stiffness, we compared the 0% strain group to cells grown on tissue culture plastic. We measured the expression of hyaluronan turnover genes, hyaluronan localization within the cell layer, hyaluronan concentration, PRG4 concentration, and the cytokine profile within the media. Our results show that the addition of cyclic loading increased HAS3 expression, but not in a magnitude-dependent response. Hyaluronidase expression was impacted by strain magnitude, which is exemplified by the decrease in hyaluronan concentration due to cyclic loading. We also show that PRG4 concentration is increased at 5% strain, while higher strain magnitude decreases overall PRG4 concentration. Finally, 10% and 20% strain show a distinct, more pro-inflammatory cytokine profile when compared to the unloaded group. Multivariate analysis showed distinct separation between certain strain groups in being able to predict strain group, hyaluronan concentration, and PRG4 concentration from gene expression or cytokine concentration data, highlighting the complexity of the system. Overall, this study shows that cyclic loading can be used tool to modulate the endogenous production of hyaluronan, PRG4, and cytokines from synovial fibroblasts.
Collapse
Affiliation(s)
- Meghana Pendyala
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York, United States of America
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, United States of America
| | - Paige S Woods
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, Connecticut, United States of America
| | - Douglas K Brubaker
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, United States of America
- Regenstrief Center for Healthcare Engineering, Purdue University, West Lafayette, Indiana, United States of America
| | - Elizabeth A Blaber
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York, United States of America
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, United States of America
- Blue Marble Space Institute of Science at NASA Ames Research Center, Moffett Field, California, United States of America
| | - Tannin A Schmidt
- Department of Biomedical Engineering, University of Connecticut Health Center, Farmington, Connecticut, United States of America
| | - Deva D Chan
- Department of Biomedical Engineering, Rensselaer Polytechnic Institute, Troy, New York, United States of America
- Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, New York, United States of America
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, United States of America
| |
Collapse
|
8
|
Recombinant Human Proteoglycan 4 (rhPRG4) Downregulates TNFα-Stimulated NFκB Activity and FAT10 Expression in Human Corneal Epithelial Cells. Int J Mol Sci 2022; 23:ijms232112711. [DOI: 10.3390/ijms232112711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/15/2022] [Accepted: 10/17/2022] [Indexed: 11/05/2022] Open
Abstract
Dry Eye Disease (DED) is a complex pathology affecting millions of people with significant impact on quality of life. Corneal inflammation, including via the nuclear factor kappa B (NFκB) pathway, plays a key etiological role in DED. Recombinant human proteoglycan 4 (rhPRG4) has been shown to be a clinically effective treatment for DED that has anti-inflammatory effects in corneal epithelial cells, but the underlying mechanism is still not understood. Our goal was to understand if rhPRG4 affects tumor necrosis factor α (TNFα)-stimulated inflammatory activity in corneal epithelial cells. We treated hTERT-immortalized corneal epithelial (hTCEpi) cells ± TNFα ± rhPRG4 and performed Western blotting on cell lysate and RNA sequencing. Bioinformatics analysis revealed that rhPRG4 had a significant effect on TNFα-mediated inflammation with potential effects on matricellular homeostasis. rhPRG4 reduced activation of key inflammatory pathways and decreased expression of transcripts for key inflammatory cytokines, interferons, interleukins, and transcription factors. TNFα treatment significantly increased phosphorylation and nuclear translocation of p65, and rhPRG4 significantly reduced both these effects. RNA sequencing identified human leukocyte antigen (HLA)-F adjacent transcript 10 (FAT10), a ubiquitin-like modifier protein which has not been studied in the context of DED, as a key pro-inflammatory transcript increased by TNFα and decreased by rhPRG4. These results were confirmed at the protein level. In summary, rhPRG4 is able to downregulate NFκB activity in hTCEpi cells, suggesting a potential biological mechanism by which it may act as a therapeutic for DED.
Collapse
|
9
|
Lei Y, Wang X, Liao J, Shen J, Li Y, Cai Z, Hu N, Luo X, Cui W, Huang W. Shear-responsive boundary-lubricated hydrogels attenuate osteoarthritis. Bioact Mater 2022; 16:472-484. [PMID: 35415286 PMCID: PMC8967971 DOI: 10.1016/j.bioactmat.2022.02.016] [Citation(s) in RCA: 26] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 01/20/2022] [Accepted: 02/12/2022] [Indexed: 12/15/2022] Open
Abstract
Lipid-based boundary layers formed on liposome-containing hydrogels can facilitate lubrication. However, these boundary layers can be damaged by shear, resulting in decreased lubrication. Here, a shear-responsive boundary-lubricated drug-loaded hydrogel is created by incorporating celecoxib (CLX)-loaded liposomes within dynamic covalent bond-based hyaluronic acid (HA) hydrogels (CLX@Lipo@HA-gel). The dynamic cross-linked network enables the hydrogel to get restructured in response to shear, and the HA matrix allows the accumulation of internal liposome microreservoirs on the sliding surfaces, which results in the formation of boundary layers to provide stable lubrication. Moreover, hydration shells formed surrounding the hydrogel can retard the degradation process, thus helping in sustaining lubrication. Furthermore, in vitro and in vivo experiments found that CLX@Lipo@HA-gels can maintain anabolic-catabolic balance, alleviate cartilage wear, and attenuate osteoarthritis progression by delivering CLX and shear-responsive boundary lubrication. Overall, CLX@Lipo@HA-gels can serve as shear-responsive boundary lubricants and drug-delivery vehicles to alleviate friction-related diseases like osteoarthritis.
Collapse
Affiliation(s)
- Yiting Lei
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, PR China
| | - Xingkuan Wang
- Department of Orthopaedics, Affiliated Hospital of North Sichuan Medical College, No. 1 the South of Maoyuan Road, Nanchong, Sichuan, 637000, PR China
| | - Junyi Liao
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, PR China
| | - Jieliang Shen
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, PR China
| | - Yuling Li
- Department of Orthopaedics, Affiliated Hospital of North Sichuan Medical College, No. 1 the South of Maoyuan Road, Nanchong, Sichuan, 637000, PR China
| | - Zhengwei Cai
- Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, PR China
| | - Ning Hu
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, PR China
| | - Xiaoji Luo
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, PR China
| | - Wenguo Cui
- Department of Orthopaedics, Shanghai Key Laboratory for Prevention and Treatment of Bone and Joint Diseases, Shanghai Institute of Traumatology and Orthopaedics, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, 197 Ruijin 2nd Road, Shanghai, 200025, PR China
| | - Wei Huang
- Department of Orthopedics, The First Affiliated Hospital of Chongqing Medical University, Orthopedic Laboratory of Chongqing Medical University, No.1 Youyi Road, Yuzhong District, Chongqing, 400016, PR China
| |
Collapse
|
10
|
Dituri F, Gigante G, Scialpi R, Mancarella S, Fabregat I, Giannelli G. Proteoglycans in Cancer: Friends or Enemies? A Special Focus on Hepatocellular Carcinoma. Cancers (Basel) 2022; 14:cancers14081902. [PMID: 35454809 PMCID: PMC9024587 DOI: 10.3390/cancers14081902] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 04/04/2022] [Accepted: 04/08/2022] [Indexed: 12/16/2022] Open
Abstract
Simple Summary Proteoglycans affect multiple molecular and cellular processes during the progression of solid tumors with a highly desmoplastic stroma, such as HCC. Due to their role in enhancing or limiting the traits of cancer cells underlying their aggressiveness, such as proliferation, angiogenesis, epithelial to mesenchymal transition (EMT), and stemness, these macromolecules could be exploited as molecular targets or therapeutic agents. Proteoglycans, such as biglycan, versican, syndecan-1, glypican-3, and agrin, promote HCC cell proliferation, EMT, and angiogenesis, while endostatin and proteoglycan 4 were shown to impair cancer neovascularization or to enhance the sensitivity of HCC cells to drugs, such as sorafenib and regorafenib. Based on this evidence, interventional strategies involving the use of humanized monoclonal antibodies, T cells engineered with chimeric antigen receptors, or recombinant proteins mimicking potentially curative proteoglycans, are being employed or may be adopted in the near future for the treatment of HCC. Abstract Proteoglycans are a class of highly glycosylated proteins expressed in virtually all tissues, which are localized within membranes, but more often in the pericellular space and extracellular matrix (ECM), and are involved in tissue homeostasis and remodeling of the stromal microenvironment during physiological and pathological processes, such as tissue regeneration, angiogenesis, and cancer. In general, proteoglycans can perform signaling activities and influence a range of physical, chemical, and biological tissue properties, including the diffusivity of small electrolytes and nutrients and the bioavailability of growth factors. While the dysregulated expression of some proteoglycans is observed in many cancers, whether they act as supporters or limiters of neoplastic progression is still a matter of controversy, as the tumor promoting or suppressive function of some proteoglycans is context dependent. The participation of multiple proteoglycans in organ regeneration (as demonstrated for the liver in hepatectomy mouse models) and in cancer suggests that these molecules actively influence cell growth and motility, thus contributing to key events that characterize neoplastic progression. In this review, we outline the main roles of proteoglycans in the physiology and pathology of cancers, with a special mention to hepatocellular carcinoma (HCC), highlighting the translational potential of proteoglycans as targets or therapeutic agents for the treatment of this disease.
Collapse
Affiliation(s)
- Francesco Dituri
- National Institute of Gastroenterology Saverio de Bellis, IRCCS Research Hospital, Castellana Grotte, 70013 Bari, Italy; (G.G.); (R.S.); (S.M.); (G.G.)
- Correspondence:
| | - Gianluigi Gigante
- National Institute of Gastroenterology Saverio de Bellis, IRCCS Research Hospital, Castellana Grotte, 70013 Bari, Italy; (G.G.); (R.S.); (S.M.); (G.G.)
| | - Rosanna Scialpi
- National Institute of Gastroenterology Saverio de Bellis, IRCCS Research Hospital, Castellana Grotte, 70013 Bari, Italy; (G.G.); (R.S.); (S.M.); (G.G.)
| | - Serena Mancarella
- National Institute of Gastroenterology Saverio de Bellis, IRCCS Research Hospital, Castellana Grotte, 70013 Bari, Italy; (G.G.); (R.S.); (S.M.); (G.G.)
| | - Isabel Fabregat
- Oncobell Program, Bellvitge Biomedical Research Institute (IDIBELL), CIBEREHD and University of Barcelona, L’Hospitalet de Llobregat, 08908 Barcelona, Spain;
| | - Gianluigi Giannelli
- National Institute of Gastroenterology Saverio de Bellis, IRCCS Research Hospital, Castellana Grotte, 70013 Bari, Italy; (G.G.); (R.S.); (S.M.); (G.G.)
| |
Collapse
|
11
|
Takabe P, Siiskonen H, Rönkä A, Kainulainen K, Pasonen-Seppänen S. The Impact of Hyaluronan on Tumor Progression in Cutaneous Melanoma. Front Oncol 2022; 11:811434. [PMID: 35127523 PMCID: PMC8813769 DOI: 10.3389/fonc.2021.811434] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 12/31/2021] [Indexed: 12/21/2022] Open
Abstract
The incidence of cutaneous melanoma is rapidly increasing worldwide. Cutaneous melanoma is an aggressive type of skin cancer, which originates from malignant transformation of pigment producing melanocytes. The main risk factor for melanoma is ultraviolet (UV) radiation, and thus it often arises from highly sun-exposed skin areas and is characterized by a high mutational burden. In addition to melanoma-associated mutations such as BRAF, NRAS, PTEN and cell cycle regulators, the expansion of melanoma is affected by the extracellular matrix surrounding the tumor together with immune cells. In the early phases of the disease, hyaluronan is the major matrix component in cutaneous melanoma microenvironment. It is a high-molecular weight polysaccharide involved in several physiological and pathological processes. Hyaluronan is involved in the inflammatory reactions associated with UV radiation but its role in melanomagenesis is still unclear. Although abundant hyaluronan surrounds epidermal and dermal cells in normal skin and benign nevi, its content is further elevated in dysplastic lesions and local tumors. At this stage hyaluronan matrix may act as a protective barrier against melanoma progression, or alternatively against immune cell attack. While in advanced melanoma, the content of hyaluronan decreases due to altered synthesis and degradation, and this correlates with poor prognosis. This review focuses on hyaluronan matrix in cutaneous melanoma and how the changes in hyaluronan metabolism affect the progression of melanoma.
Collapse
Affiliation(s)
- Piia Takabe
- Institute of Biomedicine, University of Eastern Finland, Kuopio, Finland
| | - Hanna Siiskonen
- Department of Clinical Pathology, Kuopio University Hospital, Kuopio, Finland
| | - Aino Rönkä
- Department of Oncology, Kuopio University Hospital, Kuopio, Finland
| | - Kirsi Kainulainen
- Institute of Biomedicine, University of Eastern Finland, Kuopio, Finland
| | - Sanna Pasonen-Seppänen
- Institute of Biomedicine, University of Eastern Finland, Kuopio, Finland
- *Correspondence: Sanna Pasonen-Seppänen,
| |
Collapse
|
12
|
Matheson A, Regmi SC, Martin-Alarcon L, Jay GD, Scott WM, Schmidt TA. Proteoglycan-4 and hyaluronan composition in synovial fluid and serum from clinical equine subjects: relationship to cartilage boundary lubrication and viscosity of synovial fluid. Connect Tissue Res 2021; 62:369-380. [PMID: 32306780 DOI: 10.1080/03008207.2020.1751140] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Purpose: In experimental models of equine joint-injury and osteoarthritis synovial fluid (SF) composition (proteoglycan-4, hyaluronan) can vary, along with changes to SF mechanical function (lubrication, viscosity). The study hypotheses were a) clinical equine joint-injury and disease results in altered SF composition and diminished mechanical function, and b) serum composition (proteoglycan-4 or hyaluronan) changes concurrently. The objectives were to characterize composition (proteoglycan-4, hyaluronan), and function of SF and serum from normal horses compared to clinical groups: osteoarthritis, acute-joint-injury, and osteochondrosis.Materials and Methods: Equine samples of SF (from various joints) and blood were collected at the point-of-care. Proteoglycan-4 concentrations were measured by amplified-luminescence-proximity-assay and enzyme-linked-immunosorbent-assay in SF and serum, respectively. Molecular-weight of hyaluronan was characterized by agarose-gel-electrophoresis, and concentrations were measured by enzyme-linked-immunosorbent-assay kit. Biomechanical function of SF was characterized by an in vitro cartilage-on-cartilage friction test, and viscosity test.Results: SF proteoglycan-4 concentration increased in acute-joint-injury (1185 ± 276 versus normal 205 ± 106 µg/mL, µ± SEM, p < 0.01), with increased percentage of lower molecular-weight hyaluronan in acute-joint-injury and osteochondrosis. SF and serum proteoglycan-4 concentrations were correlated in normal horses (r2 = 0.85, p < 0.05), but not in clinical groups. Cartilage-lubricating ability was unchanged, although steady-shear viscosity of acute-joint-injury SF decreased from normal.Conclusion: Composition of SF from cases of equine acute-joint-injury changed; both proteoglycan-4 concentration and hyaluronan molecular-weight were altered, with decreased SF viscosity, but no associated changes to serum. Serum proteoglycan-4 and hyaluronan concentrations alone may not be useful biomarkers for equine joint-injury or disease.
Collapse
Affiliation(s)
- Austyn Matheson
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Suresh C Regmi
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | | | - Gregory D Jay
- Department of Emergency Medicine - Warren Alpert Medical School & School of Engineering, Brown University, Providence, RI, USA
| | - W Michael Scott
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada.,Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Tannin A Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada.,Biomedical Engineering Department, University of Connecticut Health Center, Farmington, CT, USA
| |
Collapse
|
13
|
Matheson AR, Sheehy EJ, Jay GD, Scott WM, O'Brien FJ, Schmidt TA. The role of synovial fluid constituents in the lubrication of collagen-glycosaminoglycan scaffolds for cartilage repair. J Mech Behav Biomed Mater 2021; 118:104445. [PMID: 33740688 DOI: 10.1016/j.jmbbm.2021.104445] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Revised: 02/15/2021] [Accepted: 03/02/2021] [Indexed: 11/18/2022]
Abstract
Extracellular matrix (ECM)-derived scaffolds have shown promise as tissue-engineered grafts for promoting cartilage repair. However, there has been a lack of focus on fine-tuning the frictional properties of scaffolds for cartilage tissue engineering as well as understanding their interactions with synovial fluid constituents. Proteoglycan-4 (PRG4) and hyaluronan (HA) are macromolecules within synovial fluid that play key roles as boundary mode lubricants during cartilage surface interactions. The overall objective of this study was to characterize the role PRG4 and HA play in the lubricating function of collagen-glycosaminoglycan (GAG) scaffolds for cartilage repair. As a first step towards this goal, we aimed to develop a suitable in vitro friction test to establish the boundary mode lubrication parameters for collagen-GAG scaffolds articulated against glass in a phosphate buffered saline (PBS) bath. Subsequently, we sought to leverage this system to determine the effect of physiological synovial fluid lubricants, PRG4 and HA, on the frictional properties of collagen-GAG scaffolds, with scaffolds hydrated in PBS and bovine synovial fluid (bSF) serving as negative and positive controls, respectively. At all compressive strains examined (ε = 0.1-0.5), fluid depressurization within hydrated collagen-GAG scaffolds was >99% complete at ½ minute. The coefficient of friction was stable at all compressive strains (ranging from a low 0.103 ± 0.010 at ε = 0.3 up to 0.121 ± 0.015 at ε = 0.4) and indicative of boundary-mode conditions. Immunohistochemistry demonstrated that PRG4 from recombinant human (rh) and bovine sources adsorbed to collagen-GAG scaffolds and the coefficient of friction for scaffolds immersed in rhPRG4 (0.067 ± 0.027) and normal bSF (0.056 ± 0.020) solution decreased compared to PBS (0.118 ± 0.21, both p < 0.05, at ε = 0.2). The ability of the adsorbed rhPRG4 to reduce friction on the scaffolds indicates that its incorporation within collagen-GAG biomaterials may enhance their lubricating ability as potential tissue-engineered cartilage replacements. To conclude, this study reports the development of an in vitro friction test capable of characterizing the coefficient of friction of ECM-derived scaffolds tested in a range of synovial fluid lubricants and demonstrates frictional properties as a potential design parameter for implants and materials for soft tissue replacement.
Collapse
Affiliation(s)
- Austyn R Matheson
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Eamon J Sheehy
- Tissue Engineering Research Group (TERG), Department of Anatomy and Regenerative Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland; Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin, Ireland
| | - Gregory D Jay
- Department of Emergency Medicine, Warren Alpert Medical School & School of Engineering, Brown University, Providence, RI, USA
| | - W Michael Scott
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada; Faculty of Veterinary Medicine, University of Calgary, Calgary, AB, Canada
| | - Fergal J O'Brien
- Tissue Engineering Research Group (TERG), Department of Anatomy and Regenerative Medicine, Royal College of Surgeons in Ireland, Dublin, Ireland; Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland; Advanced Materials and Bioengineering Research Centre (AMBER), Royal College of Surgeons in Ireland and Trinity College Dublin, Dublin, Ireland
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, CT, USA.
| |
Collapse
|
14
|
Dituri F, Scialpi R, Schmidt TA, Frusciante M, Mancarella S, Lupo LG, Villa E, Giannelli G. Proteoglycan-4 is correlated with longer survival in HCC patients and enhances sorafenib and regorafenib effectiveness via CD44 in vitro. Cell Death Dis 2020; 11:984. [PMID: 33199679 PMCID: PMC7669886 DOI: 10.1038/s41419-020-03180-8] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 10/27/2020] [Accepted: 10/27/2020] [Indexed: 12/13/2022]
Abstract
Sorafenib and regorafenib administration is among the preferential approaches to treat hepatocellular carcinoma (HCC), but does not provide satisfactory benefits. Intensive crosstalk occurring between cancer cells and other multiple non-cancerous cell subsets present in the surrounding microenvironment is assumed to affect tumor progression. This interplay is mediated by a number of soluble and structural extracellular matrix (ECM) proteins enriching the stromal milieu. Here we assess the HCC tumor expression of the ECM protein proteoglycan 4 (PRG4) and its potential pharmacologic activity either alone, or in combination with sorafenib and regorafenib. PRG4 mRNA levels resulted strongly correlated with increased survival rate of HCC patients (p = 0.000) in a prospective study involving 78 HCC subjects. We next showed that transforming growth factor beta stimulates PRG4 expression and secretion by primary human HCC cancer-associated fibroblasts, non-invasive HCC cell lines, and ex vivo specimens. By functional tests we found that recombinant human PRG4 (rhPRG4) impairs HCC cell migration. More importantly, the treatment of HCC cells expressing CD44 (the main PRG4 receptor) with rhPRG4 dramatically enhances the growth-limiting capacity of sorafenib and regorafenib, whereas not significantly affecting cell proliferation per se. Conversely, rhPRG4 only poorly potentiates drug effectiveness on low CD44-expressing or stably CD44-silenced HCC cells. Overall, these data suggest that the physiologically-produced compound PRG4 may function as a novel tumor-suppressive agent by strengthening sorafenib and regorafenib effects in the treatment of HCC.
Collapse
Affiliation(s)
- Francesco Dituri
- National Institute of Gastroenterology "S. De Bellis" Research Hospital, 70013, Castellana Grotte, Italy.
| | - Rosanna Scialpi
- National Institute of Gastroenterology "S. De Bellis" Research Hospital, 70013, Castellana Grotte, Italy
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Centre, Farmington, CT, USA
| | - Martina Frusciante
- National Institute of Gastroenterology "S. De Bellis" Research Hospital, 70013, Castellana Grotte, Italy
| | - Serena Mancarella
- National Institute of Gastroenterology "S. De Bellis" Research Hospital, 70013, Castellana Grotte, Italy
| | - Luigi Giovanni Lupo
- University of Bari, Department of General Surgery and Liver Transplantation, Policlinico - piazza Giulio Cesare 14, 70125, Bari, Italy
| | - Erica Villa
- Gastroenterology Unit, Department of Internal Medicine, University of Modena and Reggio Emilia, Modena, Italy
| | - Gianluigi Giannelli
- National Institute of Gastroenterology "S. De Bellis" Research Hospital, 70013, Castellana Grotte, Italy
| |
Collapse
|
15
|
Cook SG, Bonassar LJ. Interaction with Cartilage Increases the Viscosity of Hyaluronic Acid Solutions. ACS Biomater Sci Eng 2020; 6:2787-2795. [PMID: 33463274 DOI: 10.1021/acsbiomaterials.0c00100] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Injection of hyaluronic acid (HA) viscosupplements is a prevalent treatment for patients suffering from mild to moderate osteoarthritis. The efficacy of these supplements is attributed to increased synovial fluid viscosity, which leads to improved lubrication and reduced pain. Therefore, viscosity is a key parameter to consider in the development of HA supplements. HA localizes near the cartilage surface, resulting in a viscosity gradient with heightened viscosity near the surface. Traditional rheological measurements confine HA between metal fixtures and therefore do not capture the effect of HA localization that occurs on cartilage. In these experiments, we investigate the effect of modifying rheometer fixtures with cartilage surface coatings on the effective viscosity of HA solutions. Our results demonstrate up to a 20-fold increase in effective viscosity when HA was confined between cartilage surfaces compared to steel surfaces. For low-molecular-weight HA, the effective viscosity was dependent on the gap height between the rheometer plates, which is consistent with the formation of a viscous boundary film. Together, these results indicate that this method for assessing HA viscosity may be more relevant to lubrication than traditional methods and may provide a more accurate method for predicting the viscosity of HA viscosupplements in vivo where HA is able to interact with the cartilage surface.
Collapse
Affiliation(s)
- Sierra G Cook
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York 14853, United States
| | - Lawrence J Bonassar
- Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York 14853, United States.,Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York 14853, United States
| |
Collapse
|
16
|
Furmann D, Nečas D, Rebenda D, Čípek P, Vrbka M, Křupka I, Hartl M. The Effect of Synovial Fluid Composition, Speed and Load on Frictional Behaviour of Articular Cartilage. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E1334. [PMID: 32183442 PMCID: PMC7143089 DOI: 10.3390/ma13061334] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 03/06/2020] [Accepted: 03/13/2020] [Indexed: 12/22/2022]
Abstract
Articular cartilage ensures smooth motion of natural synovial joints operating at very low friction. However, the number of patients suffering from joint diseases, usually associated with cartilage degradation, continuously increases. Therefore, an understanding of cartilage tribological behaviour is of great interest in order to minimize its degradation, preserving the reliable function of the joints. The aim of the present study is to provide a comprehensive comparison of frictional behaviour of articular cartilage, focusing on the effect of synovial fluid composition (i), speed (ii), and load (iii). The experiments were realized using a pin-on-plate tribometer with reciprocating motion. The articular cartilage pin was loaded against smooth glass plate while the tests consisted of loading and unloading phases in order to enable cartilage rehydration. Various model fluids containing albumin, γ-globulin, hyaluronic acid, and phospholipids were prepared in two different concentrations simulating physiologic and osteoarthritic synovial fluid. Two different speeds, 5 mm/s and 10 mm/s were applied, and the tests were carried out under 5 N and 10 N. It was found that protein-based solutions exhibit almost no difference in friction coefficient, independently of the concentration of the constituents. However, the behaviour is considerably changed when adding hyaluronic acid and phospholipids. Especially when interacting with γ-globulin, friction coefficient decreased substantially. In general, an important role of the interaction of fluid constituents was observed. On the other hand, a limited effect of speed was detected for most of the model fluids. Finally, it was shown that elevated load leads to lower friction, which corresponds well with previous observations. Further study should concentrate on specific explored phenomena focusing on the detailed statistical evaluation.
Collapse
Affiliation(s)
- Denis Furmann
- Faculty of Mechanical Engineering, Brno University of Technology, Brno 616 69, Czech Republic
| | - David Nečas
- Faculty of Mechanical Engineering, Brno University of Technology, Brno 616 69, Czech Republic
| | - David Rebenda
- Faculty of Mechanical Engineering, Brno University of Technology, Brno 616 69, Czech Republic
| | - Pavel Čípek
- Faculty of Mechanical Engineering, Brno University of Technology, Brno 616 69, Czech Republic
| | - Martin Vrbka
- Faculty of Mechanical Engineering, Brno University of Technology, Brno 616 69, Czech Republic
| | - Ivan Křupka
- Faculty of Mechanical Engineering, Brno University of Technology, Brno 616 69, Czech Republic
| | - Martin Hartl
- Faculty of Mechanical Engineering, Brno University of Technology, Brno 616 69, Czech Republic
| |
Collapse
|
17
|
Hayes AJ, Melrose J. Glycosaminoglycan and Proteoglycan Biotherapeutics in Articular Cartilage Protection and Repair Strategies: Novel Approaches to Visco‐supplementation in Orthobiologics. ADVANCED THERAPEUTICS 2019. [DOI: 10.1002/adtp.201900034] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Affiliation(s)
- Anthony J. Hayes
- Bioimaging Research HubCardiff School of BiosciencesCardiff University Cardiff CF10 3AX Wales UK
| | - James Melrose
- Graduate School of Biomedical EngineeringUNSW Sydney Sydney NSW 2052 Australia
- Raymond Purves Bone and Joint Research LaboratoriesKolling Institute of Medical ResearchRoyal North Shore Hospital and The Faculty of Medicine and HealthUniversity of Sydney St. Leonards NSW 2065 Australia
- Sydney Medical SchoolNorthernRoyal North Shore HospitalSydney University St. Leonards NSW 2065 Australia
| |
Collapse
|
18
|
Bloom AK, Samsom ML, Regmi SC, Steele BL, Schmidt TA. Investigating the effect of proteoglycan 4 on hyaluronan solution properties using confocal fluorescence recovery after photobleaching. BMC Musculoskelet Disord 2019; 20:93. [PMID: 30808331 PMCID: PMC6391837 DOI: 10.1186/s12891-019-2469-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 02/18/2019] [Indexed: 11/17/2022] Open
Abstract
Background The objective of this study was to use confocal fluorescence recovery after photobleaching (FRAP) to examine the specific and dose-dependent effect of proteoglycan 4 (PRG4) on hyaluronan (HA) solutions of different molecular weight; and assess the effect of reduction and alkylation (R/A) of PRG4 on its effects on HA solutions. Methods Confocal FRAP was used to determine the diffusion coefficient of fluorescein isothiocyanate (FITC)-dextran tracer (Dt) through 1500 kDa and 500 kDa HA solutions (0–3.3 mg/ml) ± PRG4 or a control protein, bovine serum albumin (BSA), at physiological (450 μg/ml) or pathophysiological (45 μg/ml) concentrations. The effect of PRG4 or R/A PRG4 on 1500 kDa HA solutions was also investigated. Empirical constants obtained from fitting data to the universal scaling equation were used to calculate the average distribution of apparent mesh sizes. Results PRG4 at both 45 and 450 μg/ml slowed the diffusion of the FITC-dextran tracer for all concentrations of HA and caused a decrease in the apparent mesh size within the HA solution. This effect was specific to PRG4, not observed with BSA, but not dependent on its tertiary/quaternary structure as the effect remained after R/A of PRG4. Conclusions These results demonstrate that PRG4 can significantly alter the solution properties of HA; PRG4 essentially reduced the permeability of the HA network. This effect may be due to PRG4 entangling HA molecules through binding and/or HA crowding PRG4 molecules into a self-assembled network. Collectively these findings contribute to the understanding of PRG4 and HA interaction(s) in solution and therefore the function of SF in diarthroidal joints.
Collapse
Affiliation(s)
- Adam K Bloom
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Michael L Samsom
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada
| | - Suresh C Regmi
- Faculty of Kinesiology, KNB 426, 2500 University Dr. NW, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Bridgett L Steele
- Faculty of Kinesiology, KNB 426, 2500 University Dr. NW, University of Calgary, Calgary, AB, T2N 1N4, Canada
| | - Tannin A Schmidt
- Biomedical Engineering Graduate Program, University of Calgary, Calgary, AB, Canada. .,Faculty of Kinesiology, KNB 426, 2500 University Dr. NW, University of Calgary, Calgary, AB, T2N 1N4, Canada. .,Biomedical Engineering Department, University of Connecticut Health Center, Farmington, CT, USA.
| |
Collapse
|
19
|
Huang J, Qiu X, Xie L, Jay GD, Schmidt TA, Zeng H. Probing the Molecular Interactions and Lubrication Mechanisms of Purified Full-Length Recombinant Human Proteoglycan 4 (rhPRG4) and Hyaluronic Acid (HA). Biomacromolecules 2019; 20:1056-1067. [PMID: 30608145 DOI: 10.1021/acs.biomac.8b01678] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Probing the adsorption and lubrication behavior of lubricin, also known as proteoglycan 4 (PRG4), is important for understanding the ultralow friction of cartilage lubrication. Most previous research has focused on native lubricin either purified from synovial fluid or articular cartilage explant culture media. In this work, the adsorption behavior and lubrication mechanism of full-length recombinant human PRG4 (rhPRG4) on mica as well as the effect of adding hyaluronic acid (HA, a polysaccharide) were systematically investigated using a surface forces apparatus (SFA) technique. A low friction coefficient (μ ∼ 0.04) was measured when multilayer rhPRG4 (∼31 nm) was confined in between mica surfaces, even when the load increased to ∼1.2 MPa. Intriguingly, a previously unreported ultralow friction coefficient (μ < 0.005) was observed at a low sliding velocity ( v = 0.14 μm/s) with the applied load P reaching ∼3.6 MPa when a diluted rhPRG4 solution (∼90 μg/mL) was used. The distinct friction behavior is likely due to the smooth and more close-packed lubricin coating, as made evident by the atomic force microscope imaging. Adding HA onto multilayer rhPRG4-coated mica increased the friction coefficient μ to ∼0.1; however, the load bearing property increased, indicating potential synergistic effect between rhPRG4 and HA, which was further demonstrated by the weak adhesion observed when separating rhPRG4-coated mica and HA-coated aminopropyltriethoxysilane-mica (APTES-mica). Alternatively, adding premixed rhPRG4-HA on mica had a friction coefficient (μ ∼ 0.1) close to that of injecting concentrated rhPRG4 (∼450 μg/mL) with lower load sustainability. Our results provide fundamental insights into the adsorption and lubrication behavior of lubricin and its interaction with HA, with useful implications for the underlying mechanism of ultralow friction provided by synovial fluid.
Collapse
Affiliation(s)
- Jun Huang
- Center for Advanced Jet Engineering Technologies (CaJET), Key Laboratory of High-efficiency and Clean Mechanical Manufacture (Ministry of Education), Department of Mechanical Engineering , Shandong University , Jingshi Road 17923 , Jinan 250061 , China.,Department of Chemical and Materials Engineering , University of Alberta , Edmonton , Alberta T6G 1H9 , Canada
| | - Xiaoyong Qiu
- Department of Chemical and Materials Engineering , University of Alberta , Edmonton , Alberta T6G 1H9 , Canada
| | - Lei Xie
- Department of Chemical and Materials Engineering , University of Alberta , Edmonton , Alberta T6G 1H9 , Canada
| | - Gregory D Jay
- Department of Emergency Medicine , Warren Alpert Medical School of Brown University , Providence , Rhode Island 02903 , United States.,Department of Engineering , Brown University , Providence , Rhode Island 02903 , United States
| | - Tannin A Schmidt
- Biomedical Engineering Department, School of Dental Medicine , University of Connecticut Health Center , 263 Farmington Avenue , Farmington , Connecticut 06030 , United States
| | - Hongbo Zeng
- Department of Chemical and Materials Engineering , University of Alberta , Edmonton , Alberta T6G 1H9 , Canada
| |
Collapse
|
20
|
Kobler JB, Tynan MA, Zeitels SM, Liss AS, Gianatasio MT, Morin AA, Schmidt TA. Lubricin/proteoglycan 4 detected in vocal folds of humans and five other mammals. Laryngoscope 2019; 129:E229-E237. [PMID: 30613972 DOI: 10.1002/lary.27783] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/10/2018] [Indexed: 12/28/2022]
Abstract
OBJECTIVES/HYPOTHESIS Lubricin/proteoglycan-4 (PRG4) lubricates connective tissues such as joints and tendon sheaths, enabling them to better withstand shearing and frictional forces during motion. We wondered whether PRG4 might play a role in phonation, as normal vocal folds withstand repetitive, high-velocity deformations remarkably well. As a first step, we tested whether PRG4 is expressed in vocal folds. STUDY DESIGN Laboratory study. METHODS Anatomical and molecular methods were applied to 47 larynges from humans, macaque (Macaca fascicularis), canines, pigs, calves, and rats. Immunohistochemistry (IHC), Western blot, and quantitative real-time polymerase chain reaction (qRT-PCR) methods were used to test for the presence of PRG4. RESULTS In all species, the true vocal fold lamina propria (TVF-LP) was positive for PRG4 by IHC, whereas immunoreactivity of the false vocal fold was weak or absent, depending on the species. Human TVF-LP was strongly stained across all layers. Immunoreactivity was seen variably on the vocal fold surface and within the vocal fold epithelium, in the conus elasticus and thyroglottic ligament, and at the tip of vocal process. Western blots of four humans and six pigs demonstrated immunoreactivity at appropriate molecular weight. qRT-PCR of pig tissues confirmed PRG4 mRNA expression, which was highest in the TVF-LP. CONCLUSIONS PRG4 was found in phonatory tissues of six mammals. We suggest it might act as a lubricant within the lamina propria and possibly on the vocal fold surface, limiting phonation-related damage to vocal fold extracellular matrix and epithelium, and enhancing vocal efficiency by reducing internal friction (viscosity) within the vocal fold. LEVEL OF EVIDENCE NA Laryngoscope, 129:E229-E237, 2019.
Collapse
Affiliation(s)
- James B Kobler
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A.,Department of Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Monica A Tynan
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A
| | - Steven M Zeitels
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A.,Department of Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Andrew S Liss
- Center for Laryngeal Surgery and Voice Rehabilitation, Massachusetts General Hospital, Boston, Massachusetts, U.S.A.,Department of Surgery, Harvard Medical School, Boston, Massachusetts, U.S.A
| | - Maria T Gianatasio
- Cancer Center Histopathology Core, Massachusetts General Hospital, Boston, Massachusetts, U.S.A
| | - Alyssa A Morin
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, Connecticut, U.S.A
| | - Tannin A Schmidt
- Biomedical Engineering Department, University of Connecticut Health Center, Farmington, Connecticut, U.S.A
| |
Collapse
|
21
|
Morgese G, Benetti EM, Zenobi-Wong M. Molecularly Engineered Biolubricants for Articular Cartilage. Adv Healthc Mater 2018; 7:e1701463. [PMID: 29717824 DOI: 10.1002/adhm.201701463] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2017] [Revised: 03/07/2018] [Indexed: 12/15/2022]
Abstract
Lubrication within articular joints plays a crucial role in daily life, providing an extremely low coefficient of friction and preventing wear at the surface of the articular cartilage. Natural biomacromolecules responsible for lubrication are part of the synovial fluid and their degradation is associated with the onset of degenerative diseases, such as osteoarthritis (OA). The current absence of effective treatments for OA has captured the attention of chemists and material scientists over the last two decades, triggering the development of partially or fully synthetic biolubricants aimed to reduce friction within the joints and restore cartilage functions. Although there is still a long way to go before synthetic replacements of natural biolubricants can be applied clinically, this review highlights those formulations that meet the fundamental requirements for being efficient lubricants for articular cartilage.
Collapse
Affiliation(s)
- Giulia Morgese
- Polymer Surfaces Group; Laboratory for Surface Science and Technology; Department of Materials; ETH Zürich; Zürich 8093 Switzerland
- Tissue Engineering and Biofabrication Group; Department of Health Science and Technology; ETH Zürich; Zürich 8093 Switzerland
| | - Edmondo M. Benetti
- Polymer Surfaces Group; Laboratory for Surface Science and Technology; Department of Materials; ETH Zürich; Zürich 8093 Switzerland
| | - Marcy Zenobi-Wong
- Tissue Engineering and Biofabrication Group; Department of Health Science and Technology; ETH Zürich; Zürich 8093 Switzerland
| |
Collapse
|
22
|
Qadri MM, Jay GD, Ostrom RS, Zhang LX, Elsaid KA. cAMP attenuates TGF-β's profibrotic responses in osteoarthritic synoviocytes: involvement of hyaluronan and PRG4. Am J Physiol Cell Physiol 2018; 315:C432-C443. [PMID: 29898378 DOI: 10.1152/ajpcell.00041.2018] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
Osteoarthritis (OA) is characterized by synovitis and synovial fibrosis. Synoviocytes are fibroblast-like resident cells of the synovium that are activated by transforming growth factor (TGF)-β to proliferate, migrate, and produce extracellular matrix. Synoviocytes secrete hyaluronan (HA) and proteoglycan-4 (PRG4). HA reduces synovial fibrosis in vivo, and the Prg4-/- mouse exhibits synovial hyperplasia. We investigated the antifibrotic effects of increased intracellular cAMP in TGF-β-stimulated human OA synoviocytes. TGF-β1 stimulated collagen I (COL1A1), α-smooth muscle actin (α-SMA), tissue inhibitor of metalloproteinase (TIMP)-1, and procollagen-lysine, 2-oxoglutarate 5-dioxygenase 2 (PLOD2) expression, and procollagen I, α-SMA, HA, and PRG4 production, migration, and proliferation of OA synoviocytes were measured. Treatment of OA synoviocytes with forskolin (10 μM) increased intracellular cAMP levels and reduced TGF-β1-stimulated COL1A1, α-SMA, and TIMP-1 expression, with no change in PLOD2 expression. Forskolin also reduced TGF-β1-stimulated procollagen I and α-SMA content as well as synoviocyte migration and proliferation. Forskolin (10 μM) increased HA secretion and PRG4 expression and production. A cell-permeant cAMP analog reduced COL1A1 and α-SMA expression and enhanced HA and PRG4 secretion by OA synoviocytes. HA and PRG4 reduced α-SMA expression and content, and PRG4 reduced COL1A1 expression and procollagen I content in OA synoviocytes. Prg4-/- synovium exhibited increased α-SMA, COL1A1, and TIMP-1 expression compared with Prg4+/+ synovium. Prg4-/- synoviocytes demonstrated strong α-SMA and collagen type I staining, whereas these were undetected in Prg4+/+ synoviocytes and were reduced with PRG4 treatment. We conclude that increasing intracellular cAMP levels in synoviocytes mitigates synovial fibrosis through enhanced production of HA and PRG4, possibly representing a novel approach for treatment of OA synovial fibrosis.
Collapse
Affiliation(s)
- Marwa M Qadri
- Department of Biomedical and Pharmaceutical Sciences, School of Pharmacy, Chapman University , Irvine, California
| | - Gregory D Jay
- Department of Emergency Medicine, Rhode Island Hospital , Providence, Rhode Island.,Department of Biomedical Engineering, Brown University , Providence, Rhode Island
| | - Rennolds S Ostrom
- Department of Biomedical and Pharmaceutical Sciences, School of Pharmacy, Chapman University , Irvine, California
| | - Ling X Zhang
- Department of Emergency Medicine, Rhode Island Hospital , Providence, Rhode Island
| | - Khaled A Elsaid
- Department of Biomedical and Pharmaceutical Sciences, School of Pharmacy, Chapman University , Irvine, California
| |
Collapse
|
23
|
Yilmaz S, Uludağ Alkaya D, Kasapçopur Ö, Barut K, Akdemir ES, Celen C, Youngblood MW, Yasuno K, Bilguvar K, Günel M, Tüysüz B. Genotype-phenotype investigation of 35 patients from 11 unrelated families with camptodactyly-arthropathy-coxa vara-pericarditis (CACP) syndrome. Mol Genet Genomic Med 2018; 6:230-248. [PMID: 29397575 PMCID: PMC5902402 DOI: 10.1002/mgg3.364] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Revised: 11/12/2017] [Accepted: 11/16/2017] [Indexed: 11/09/2022] Open
Abstract
Background The camptodactyly–arthropathy–coxa vara–pericarditis syndrome (CACP) is a rare autosomal recessive condition characterized by camptodactyly, noninflammatory arthropathy, coxa vara, and pericarditis. CACP is caused by mutations in the proteoglycan 4 (PRG4) gene, which encodes a lubricating glycoprotein present in the synovial fluid and at the surface of articular cartilage. Methods In the present study, we compared the clinical and molecular findings of CACP syndrome in 35 patients from 11 unrelated families. In 28 patients, whole exome sequencing was used to investigate genomic variations. Results We found that camptodactyly of hands was the first symptom presented by most patients. Swelling of wrists, knees, and elbows began before 4 years of age, while the age of joint involvement was variable. Patients reported an increased pain level after the age of 10, and severe hip involvement developed after 20 years old. All patients presented developmental coxa vara and seven patients (~22%) had pleural effusion, pericarditis, and/or ascites. We identified nine novel genomic alterations, including the first case of homozygous complete deletion of exon 1 in the PRG4 gene. Conclusion With this study, we contribute to the catalog of CACP causing variants. We confirm that the skeletal component of this disease worsens with age, and presents the potential mechanisms for interfamily variability, by discussing the influence of a modifier gene and escape from nonsense‐mediated mRNA decay. We believe that this report will increase awareness of this familial arthropathic condition and the characteristic clinical and radiological findings will facilitate the differentiation from the common childhood rheumatic diseases such as juvenile idiopathic arthritis.
Collapse
Affiliation(s)
- Saliha Yilmaz
- Department of Neurosurgery, Program on Neurogenetics, Yale School of Medicine, Yale University, New Haven, CT, USA
| | - Dilek Uludağ Alkaya
- Department of Pediatric Genetics, Cerrahpasa Medical Faculty, Istanbul University, Istanbul, Turkey
| | - Özgür Kasapçopur
- Department of Pediatric Rheumatology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul, Turkey
| | - Kenan Barut
- Department of Pediatric Rheumatology, Cerrahpasa Medical Faculty, Istanbul University, Istanbul, Turkey
| | - Ekin S Akdemir
- Department of Neurosurgery, Program on Neurogenetics, Yale School of Medicine, Yale University, New Haven, CT, USA
| | - Cemre Celen
- Department of Neurosurgery, Program on Neurogenetics, Yale School of Medicine, Yale University, New Haven, CT, USA
| | - Mark W Youngblood
- Department of Neurosurgery, Program on Neurogenetics, Yale School of Medicine, Yale University, New Haven, CT, USA
| | - Katsuhito Yasuno
- Department of Neurosurgery, Program on Neurogenetics, Yale School of Medicine, Yale University, New Haven, CT, USA
| | - Kaya Bilguvar
- Department of Genetics, Yale Center for Genome Analysis, Yale School of Medicine, New Haven, CT, USA
| | - Murat Günel
- Department of Neurosurgery, Program on Neurogenetics, Yale School of Medicine, Yale University, New Haven, CT, USA
| | - Beyhan Tüysüz
- Department of Pediatric Genetics, Cerrahpasa Medical Faculty, Istanbul University, Istanbul, Turkey
| |
Collapse
|
24
|
Boutefnouchet T, Puranik G, Holmes E, Bell KM. Hylan GF-20 Viscosupplementation in the Treatment of Symptomatic Osteoarthritis of the Knee: Clinical Effect Survivorship at 5 Years. Knee Surg Relat Res 2017; 29:129-136. [PMID: 28545178 PMCID: PMC5450575 DOI: 10.5792/ksrr.16.061] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 03/13/2017] [Accepted: 04/23/2017] [Indexed: 11/19/2022] Open
Abstract
Purpose Controversies remain surrounding the choice of hyaluronic acid products and patient selection. A study was conducted to report the long-term survivorship of intra-articular injection effect of high molecular weight hyaluronic preparation hylan GF-20 (Synvisc-One) for patients with symptomatic knee osteoarthritis. Materials and Methods A retrospective observational analysis of a single therapeutic series was carried out. The analysis was conducted to determine therapeutic effect survivorship taking arthroplasty and any other surgical interventions as endpoint results. Results Seventy-seven consecutive patients (82 knees) were followed up for five years. At one-year follow-up, 71 knees (87%) responded to treatment and only 8 knees (10%) were offered arthroplasty due to persistence of symptoms. At five-year follow-up, 41 (50%) were still considered responders. During the study period, repeat injection was given in 9 knees (11%). Arthroplasty (either total or unicompartmental) was required in 26 (31%). Kaplan-Meier survivorship analysis of therapeutic effect demonstrated 67% survival at 5 years with arthroplasty as endpoint and 58% survival at 5 years with all secondary interventions as endpoint. Conclusions This study demonstrates a significantly longer duration of clinical benefit of hylan GF-20 injection. Present results may suggest a notion of an ideal delay therapeutic strategy for patients not ready to receive an arthroplasty. Further studies will be required to help characterise these subsets of patients.
Collapse
Affiliation(s)
- Tarek Boutefnouchet
- Department of Trauma Orthopaedics, University Hospital Coventry and Warwickshire NHS Trust, Coventry, UK
| | - Guru Puranik
- Department of Trauma Orthopaedics, Alexandra Hospital, Redditch, UK
| | - Esther Holmes
- Department of Trauma Orthopaedics, Alexandra Hospital, Redditch, UK
| | - Karl M Bell
- Department of Trauma Orthopaedics, Alexandra Hospital, Redditch, UK
| |
Collapse
|
25
|
Larson KM, Zhang L, Elsaid KA, Schmidt TA, Fleming BC, Badger GJ, Jay GD. Reduction of friction by recombinant human proteoglycan 4 in IL-1α stimulated bovine cartilage explants. J Orthop Res 2017; 35:580-589. [PMID: 27411036 PMCID: PMC5957283 DOI: 10.1002/jor.23367] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Accepted: 07/02/2016] [Indexed: 02/04/2023]
Abstract
A boundary lubricant attaches and protects sliding bearing surfaces by preventing interlocking asperity-asperity contact. Proteoglycan-4 (PRG4) is a boundary lubricant found in the synovial fluid that provides chondroprotection to articular surfaces. Inflammation of the diarthrodial joint modulates local PRG4 concentration. Thus, we measured the effects of inflammation, with Interleukin-1α (IL-1α) incubation, upon boundary lubrication and PRG4 expression in bovine cartilage explants. We further aimed to determine whether the addition of exogenous human recombinant PRG4 (rhPRG4) could mitigate the effects of inflammation on boundary lubrication and PRG4 expression in vitro. Cartilage explants, following a 7 day incubation with IL-1α, were tested in a disc-on-disc configuration using either rhPRG4 or saline (PBS control) as a lubricant. Following mechanical testing, explants were studied immunohistochemically or underwent RNA extraction for real-time polymerase chain reaction (RT-PCR). We found that static coefficient of friction (COF) significantly decreased to 0.14 ± 0.065 from 0.21 ± 0.059 (p = 0.014) in IL-1α stimulated explants lubricated with rhPRG4, as compared to PBS. PRG4 expression was significantly up regulated from 30.8 ± 19 copies in control explants lubricated with PBS to 3330 ± 1760 copies in control explants lubricated with rhPRG4 (p < 0.001). Explants stimulated with IL-1α displayed no increase in PRG4 expression upon lubrication with rhPRG4, but with PBS as the lubricant, IL-1α stimulation significantly increased PRG4 expression compared to the control condition from 30.8 ± 19 copies to 401 ± 340 copies (p = 0.015). Overall, these data suggest that exogenous rhPRG4 may provide a therapeutic option for reducing friction in transient inflammatory conditions and increasing PRG4 expression. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:580-589, 2017.
Collapse
Affiliation(s)
- Katherine M. Larson
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI, USA
| | - Ling Zhang
- Emergency Medicine Research Laboratory, Department of Emergency Medicine, Rhode Island Hospital, Providence, RI, USA
| | - Khaled A. Elsaid
- Department of Biomedical and Pharmaceutical Sciences, Chapman University School of Pharmacy, Irvine, CA, USA
| | - Tannin A. Schmidt
- Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada,Schulich School of Engineering, University of Calgary, Calgary, AB, Canada
| | - Braden C. Fleming
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI, USA,Bioengineering Laboratory, Department of Orthopaedics, Warren Alpert Medical School of Brown University and Rhode Island Hospital, Providence, RI, USA
| | - Gary J. Badger
- Department of Medical Biostatistics, University of Vermont, Burlington, VT, USA
| | - Gregory D. Jay
- Center for Biomedical Engineering and School of Engineering, Brown University, Providence, RI, USA,Emergency Medicine Research Laboratory, Department of Emergency Medicine, Rhode Island Hospital, Providence, RI, USA,Department of Emergency Medicine, Warren Alpert Medical School of Brown University, Providence, RI, USA
| |
Collapse
|
26
|
Samaroo KJ, Tan M, Putnam D, Bonassar LJ. Binding and lubrication of biomimetic boundary lubricants on articular cartilage. J Orthop Res 2017; 35:548-557. [PMID: 27419808 DOI: 10.1002/jor.23370] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2016] [Accepted: 02/07/2016] [Indexed: 02/04/2023]
Abstract
The glycoprotein, lubricin, is the primary boundary lubricant of articular cartilage and has been shown to prevent cartilage damage after joint injury. In this study, a library of eight bottle-brush copolymers were synthesized to mimic the structure and function of lubricin. Polyethylene glycol (PEG) grafted onto a polyacrylic acid (pAA) core mimicked the hydrophilic mucin-like domain of lubricin, and a thiol terminus anchored the polymers to cartilage surfaces much like lubricin's C-terminus. These copolymers, abbreviated as pAA-g-PEG, rapidly bound to cartilage surfaces with binding time constants ranging from 20 to 39 min, and affected lubrication under boundary mode conditions with coefficients of friction ranging from 0.140 ± 0.024 to 0.248 ± 0.030. Binding and lubrication were highly correlated (r2 = 0.89-0.99), showing that boundary lubrication in this case strongly depends on the binding of the lubricant to the surface. Along with time-dependent and dose-dependent behavior, lubrication and binding of the lubricin-mimetics also depended on copolymer structural parameters including pAA backbone length, PEG side chain length, and PEG:AA brush density. Polymers with larger backbone sizes, brush sizes, or brush densities took longer to bind (p < 0.05). Six of the eight polymers reduced friction relative to denuded cartilage plugs (p < 0.05), suggesting their potential to lubricate and protect cartilage in vivo. In copolymers with shorter pAA backbones, increasing hydrodynamic size inhibited lubrication (p < 0.08), while the opposite was observed in copolymers with longer backbones (p < 0.05). These polymers show similar in vitro lubricating efficacy as recombinant lubricins and as such have potential for in vivo treatment of post-traumatic osteoarthritis. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:548-557, 2017.
Collapse
Affiliation(s)
- Kirk J Samaroo
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York
| | - Mingchee Tan
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, 149 Weill Hall, Ithaca, New York, 14853
| | - David Putnam
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, 149 Weill Hall, Ithaca, New York, 14853
- School of Chemical and Biomolecular Engineering, Cornell University, Ithaca, New York
| | - Lawrence J Bonassar
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, 149 Weill Hall, Ithaca, New York, 14853
| |
Collapse
|