1
|
Saini RS, Vyas R, Vaddamanu SK, Quadri SA, Mosaddad SA, Heboyan A. Efficacy of different adhesive systems in bonding direct resin composite restorations: a systematic review and meta-analysis. Evid Based Dent 2025:10.1038/s41432-024-01095-3. [PMID: 39775156 DOI: 10.1038/s41432-024-01095-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2024] [Accepted: 11/18/2024] [Indexed: 01/11/2025]
Abstract
OBJECTIVE This study aimed to identify and evaluate scholarly research on the efficacy, durability, and long-term stability of various adhesive systems used for bonding direct resin composite restorations and to identify factors influencing bonding performance, such as adhesive composition, application protocol, substrate type, and etching technique. MATERIALS AND METHODS An all-inclusive electronic database search for peer-reviewed scholarly journal articles was conducted using PubMed, ScienceDirect, Google Scholar, Dimensions, and the Cochrane Library for research articles investigating the effectiveness of different adhesive systems in direct resin composite restorations, excluding reviews, meta-analyses, opinion pieces, and case reports. The risk of bias was assessed using the Cochrane tool (Robvis 2.0). Data were extracted and thematically analyzed, and quantitative data were statistically analyzed using Review Manager software. Dichotomous data were evaluated using the Mantel-Haenszel method, applying a random effects model and 95% confidence interval. RESULTS The database search yielded 1632 potential articles, of which 14 were included in this study. Several adhesive systems exhibit excellent tensile bond strength. In addition, the type of resin composite, adhesive system, and artificial aging significantly influenced the bonding performance of resin composite restorations. However, the failure rates were low in the different adhesive systems, showing comparable results between the two-step etch-and-rinse and one-step self-etch adhesive systems (p = 0.71). The results showed an overall trend of high bonding effectiveness with a low incidence of adverse events, such as postoperative sensitivity, adhesive failure, and fractures. CONCLUSION The study results emphasize the importance of selecting appropriate adhesive systems based on clinical case requirements, restoration characteristics, and patient factors to enhance bonding efficacy, durability, and long-term stability.
Collapse
Affiliation(s)
- Ravinder S Saini
- Department of Allied Dental Health Sciences, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Rajesh Vyas
- Department of Allied Dental Health Sciences, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Sunil Kumar Vaddamanu
- Department of Allied Dental Health Sciences, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Syed Altafuddin Quadri
- Department of Allied Dental Health Sciences, COAMS, King Khalid University, Abha, Saudi Arabia
| | - Seyed Ali Mosaddad
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
| | - Artak Heboyan
- Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India.
- Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Yerevan, Armenia.
- Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
2
|
Perdigão J, Chew HP, Lee IK, Woodis K, Hatch B. Prospective, randomized clinical trial evaluating the clinical performance of a new universal adhesive in Class I and Class II restorations at 1 year. Clin Oral Investig 2024; 29:38. [PMID: 39739062 DOI: 10.1007/s00784-024-06121-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2024] [Accepted: 12/21/2024] [Indexed: 01/02/2025]
Abstract
OBJECTIVE This randomized controlled trial compared the 1-year clinical efficacy of Scotchbond Universal Adhesive Plus (SBU+) with that of its predecessor Scotchbond Universal Adhesive (SBU) to restore Class I and Class II preparations using the self-etch strategy in adult patients. MATERIALS AND METHODS Fifty-one subjects participated in this study. Two posterior teeth in each subject were randomized to a restoration with SBU+ or to a restoration with SBU (control) using the self-etch strategy. Teeth were restored with Filtek Universal Restorative. Restorations were evaluated at baseline, 6 months and 1 year using the FDI criteria. The Wilcoxon signed-rank test was used to compare outcomes. RESULTS No restorations were graded as "Insufficient/Unsatisfactory" or "Poor" for any of the FDI criteria at the baseline, 6-month, or 1-year visits. At 1 year the retention rate was 100% for both SBU+ and SBU. For fracture of the restorative material 42/44 SBU+ restorations (95%) and 44/44 SBU restorations (100%) were graded "Excellent/Very Good" (p > 0.05). All restorations were clinically acceptable for marginal adaptation at 1 year with no statistical differences between the two adhesive materials. There were no recurrent caries lesions at the 1-year visit. CONCLUSIONS The clinical efficacy of the SBU+ at 1-year was not different to that of its predecessor SBU in Class I and Class II restorations of adult patients using the self-etch strategy. CLINICAL RELEVANCE The two dental adhesives used in this clinical trial showed excellent results in posterior restorations at 1 year without using a separate phosphoric etching step.
Collapse
Affiliation(s)
- Jorge Perdigão
- Department of Restorative Sciences, University of Minnesota School of Dentistry, Minneapolis, MN, 55455, USA.
| | - Hooi Pin Chew
- Department of Restorative Sciences, University of Minnesota School of Dentistry, Minneapolis, MN, 55455, USA
| | - Ignatius K Lee
- Department of Restorative Sciences, University of Minnesota School of Dentistry, Minneapolis, MN, 55455, USA
| | - Kacie Woodis
- Department of Primary Dental Care, University of Minnesota School of Dentistry, Minneapolis, MN, 55455, USA
| | - Brian Hatch
- Department of Primary Dental Care, University of Minnesota School of Dentistry, Minneapolis, MN, 55455, USA
| |
Collapse
|
3
|
Elderiny HM, Khallaf YS, Akah MM, Hassanein OE. Clinical Evaluation of Bioactive Injectable Resin Composite vs Conventional Nanohybrid Composite in Posterior Restorations: An 18-Month Randomized Controlled Clinical Trial. J Contemp Dent Pract 2024; 25:794-802. [PMID: 39653674 DOI: 10.5005/jp-journals-10024-3737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2024]
Abstract
AIM To evaluate the clinical performance of bioactive injectable resin composite vs nanohybrid resin composite in restoring carious posterior teeth. MATERIALS AND METHODS A total of 18 patients with 26 class I and II carious cavities were recruited. Teeth were divided into two groups (n = 13): group I: Bioactive injectable resin composite (Beautifil Flow Plus X F00) while group II: Nanohybrid resin composite (Tetric N-Ceram) and were restored according to the manufacturer's instructions. The restorations were evaluated using the modified USPHS criteria at baseline, 6, 12, and 18 months. Data were tabulated and statistically analyzed with a significant level set at (p ≤ 0.05). Using the Chi-squared test and Cochran's Q test. The survival rate was analyzed using the Kaplan-Meier and Log-rank tests. RESULTS Inter- and intra-group comparisons showed no statistically significant difference between bioactive injectable resin composite and nanohybrid resin composite at different time intervals in terms of anatomical form, marginal adaptation, secondary caries, marginal staining, postoperative sensitivity. Moreover, there was no statistically significant difference between both materials regarding the overall survival rate after 18 months. CONCLUSIONS The clinical performance of bioactive injectable resin composite and nanohybrid resin composite was similar and found to be clinically acceptable after 18 months of clinical use. CLINICAL SIGNIFICANCE Bioactive injectable resin composite can be used to restore occlusal anatomy as a nanohybrid resin composite in restoring posterior cavities with acceptable clinical performance. TRIAL REGISTRATION It was registered in (www. CLINICALTRIALS gov) database in June 2022, with identification number NCT05499494. How to cite this article: Elderiny HM, Khallaf YS, Akah MM, et al. Clinical Evaluation of Bioactive Injectable Resin Composite vs Conventional Nanohybrid Composite in Posterior Restorations: An 18-Month Randomized Controlled Clinical Trial. J Contemp Dent Pract 2024;25(8):794-802.
Collapse
Affiliation(s)
- Hazem M Elderiny
- Department of Operative Dentistry, Horus University, New Damietta, Damietta, Egypt, Phone: +01007775635, e-mail: , ORCID: https://orcid.org/0000-0002-6199-7786
| | - Yomna S Khallaf
- Department of Operative Dentistry, Cairo University, Giza, Egypt, ORCID: https://orcid.org/0000-0002-1541-6813
| | - Mai M Akah
- Department of Operative Dentistry, Cairo University, Giza; Department of Conservative and Restorative Division, Galala University, Al Galala, Suez, Egypt, ORCID: https://orcid.org/0000-0003-2306-9169
| | | |
Collapse
|
4
|
de Freitas BN, da Silva PO, Pintado-Palomino K, de Almeida CVVB, Souza-Gabriel AE, Corona SAM, Geraldeli S, Grosgogeat B, Roulet JF, Tirapelli C. Patients´ satisfaction concerning direct anterior dental restoration. Braz Dent J 2023; 34:82-93. [PMID: 37466529 PMCID: PMC10355263 DOI: 10.1590/0103-6440202305260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2022] [Accepted: 03/20/2023] [Indexed: 07/20/2023] Open
Abstract
The objective of this study was to observe patients' satisfaction with their in-service direct anterior dental restorations and to compare it with clinical evaluation using FDI (Federation Dental International) criteria. Patients scored their own anterior dental restorations regarding satisfaction (satisfactory /dissatisfactory). If dissatisfaction was mentioned, then, they would be interviewed about the complaint. In the same session, the dental restorations were clinically evaluated by two dentists using FDI criteria (1-5 score) concerning esthetic, functional, and biological domains. Descriptive statistics were used for frequencies of scores attributed by patients and clinicians. In order to compare patients' to clinicians' frequencies, the Chi-square test was applied (p ≤ 0.05). A total of 106 restorations were evaluated by patients and clinicians. Patients reported 52.8% of restorations satisfactory and 47.8% dissatisfactory. Overall, clinicians reported the same restorations as 82,3% satisfactory and 17,6% dissatisfactory. Patients' most frequent complaints referred to color, followed by anatomical form, fracture of material and retention, and approximal anatomical form. Comparing patients' satisfaction and dissatisfaction rates to clinicians' evaluation per criteria, there was no difference regarding esthetics. The frequency of dissatisfactory restorations by clinicians was significantly lower when functional and biological properties were compared with patients' opinions. Direct anterior dental restorations were more frequently reported as satisfactory by patients and clinicians, being the main complaints related to esthetic issues. When clinicians and patients' evaluations were compared, it was observed that the frequencies of satisfactory restoration by patients and clinicians were similar regarding esthetic properties, and significantly different regarding functional and biological properties.
Collapse
Affiliation(s)
- Bruna Neves de Freitas
- Department of Dental Materials and Prosthodontics, School of
Dentistry of Ribeirão Preto, University of São Paulo. Ribeirão Preto, SP,
Brazil
| | | | | | | | - Aline Evangelista Souza-Gabriel
- Department of Restorative Dentistry, School of Dentistry of
Ribeirao Preto, University of São Paulo. Ribeirão Preto, SP, Brazil
| | - Silmara Aparecida Milori Corona
- Department of Restorative Dentistry, School of Dentistry of
Ribeirao Preto, University of São Paulo. Ribeirão Preto, SP, Brazil
| | - Saulo Geraldeli
- East Carolina University, School of Dental Medicine, Department of
General Dentistry Greenville. Greenville, NC, United States of America
| | - Brigitte Grosgogeat
- Faculté d’Odontologie, Laboratoire des Multimateriaux et
Interfaces, UMR CNRS 5615, France
| | | | - Camila Tirapelli
- Department of Dental Materials and Prosthodontics, School of
Dentistry of Ribeirão Preto, University of São Paulo. Ribeirão Preto, SP,
Brazil
| |
Collapse
|
5
|
Comba A, Baldi A, Carossa M, Paolone G, Stura I, Migliaretti G, Scotti N. A Three-step Etch-and-Rinse vs a Universal Adhesive in Nanohybrid Composite Anterior Restorations: A Retrospective Clinical Evaluation. THE JOURNAL OF ADHESIVE DENTISTRY 2023; 25:87-97. [PMID: 37093568 PMCID: PMC11734306 DOI: 10.3290/j.jad.b4043039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 12/25/2022] [Accepted: 03/06/2023] [Indexed: 04/25/2023]
Abstract
PURPOSE To retrospectively evaluate the clinical behavior of direct anterior composite restorations performed with a universal adhesive or with a three-step etch-and-rinse (E&R) adhesive. MATERIAL AND METHODS Patients were randomly treated with a three-step E&R adhesive (Optibond FL, Kerr) or a universal adhesive (Clearfil Universal Bond Quick, Kuraray Noritake) applied in E&R mode. All restorations were performed with a nanohybrid composite (ClearFil Majesty ES-2, Kuraray Noritake) by the same experienced operator. Two calibrated examiners evaluated the restorations using a dental mirror and explorer, in accordance with modified United States Public Health Service (USPHS) procedures. Clinical events were registered and classified as either failure (F), survival (SR), or success (S). RESULTS 168 restorations were evaluated in 90 patients with an average follow-up period of 37.9 (± 22.9) months. A total of 132 restorations were performed on vital teeth, and 36 were performed on endodontically treated teeth (ETT). A total of 128 Class-IV and 40 Class-III restorations were performed. In 89 restorations, a three-step E&R adhesive was applied (14 Class-III and 75 Class-IV), while in 79, a universal adhesive was used (26 Class-III and 53 Class-IV, p = 0.0091). A Cox regression analysis was performed (p < 0.05) to analyze which factors were involved in the failure of the restorations, considering failure (F) as restorations that needed re-intervention at the follow-up period of 37.9 (± 22.9) months. No statistically significant differences were observed when considering parameters directly involved with the adhesives tested. Endodontically treated teeth were more prone to fractures (p = 0.0006) compared to vital teeth. Restorations made with universal adhesives failed by fracturing significantly more frequently (p = 0.0234), while restorations made on endodontically treated teeth had a significantly worse outcome (p = 0.0001). Restorations made on canines also failed significantly more frequently (HR = 3.8, 95% CI = 1.4-10.1, p = 0.0062). CONCLUSIONS Based on the obtained results, both the universal adhesive and the three-step E&R adhesive proved to be good treatment choices for direct anterior restorations after 37.9 (± 22.9) months of follow-up. Tooth vitality seems fundamental for the prognosis of a direct anterior composite restoration over time.
Collapse
Affiliation(s)
- Allegra Comba
- Assistant Professor, Department of Surgical Sciences, Dental School, University of Turin, Turin, Italy. Wrote the manuscript
| | - Andrea Baldi
- PhD Student, Department of Surgical Sciences, Dental School, University of Turin, Turin, Italy. Patient recall management and evaluation
| | - Massimo Carossa
- PhD, Clinical Tutor, Department of Surgical Sciences, Dental School, University of Turin, Turin, Italy. Revised the manuscript
| | - Gaetano Paolone
- PhD, Department of Dentistry, IRCCS San Raffaele Hospital and Dental School, Vita Salute University, Milan, Italy. Revised the manuscript
| | - Ilaria Stura
- Research Fellow, Department of Neurosciences “Rita Levi Montalcini”, University of Turin, Turin, Italy. Statistical analysis
| | - Giuseppe Migliaretti
- Associate Professor, Department of Public Health and Pediatric Sciences, University of Turin, Turin, Italy. Statistical analysis
| | - Nicola Scotti
- Associate Professor, Department of Surgical Sciences, Dental School, University of Turin, Turin, Italy. Coordinator of the research project and patient treatment
| |
Collapse
|
6
|
Al-Abd Al-Abbas MAF, Al-Badr RJ, Shamash MSA. Long-term water sorption/solubility of two dental bonding agents containing a colloidal dispersion of titanium dioxide. J Adv Pharm Technol Res 2023; 14:142-146. [PMID: 37255867 PMCID: PMC10226709 DOI: 10.4103/japtr.japtr_47_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 02/24/2023] [Accepted: 02/25/2023] [Indexed: 06/01/2023] Open
Abstract
The aim was to analyze the influence of the incorporation of 4% by mass of colloidal dispersion of titanium dioxide (TiO2) nanoparticles on the long-term water sorption and solubility of two commercial universal bonding agents. In vitro studies. A colloidal dispersion of TiO2 nanoparticles was formulated and blended into two commercial dental bonding agents, i.e., Ambar Universal (FGM, Brasil) and G-Premio Bond Universal (GC, America) at 4% by mass. Forty bonding agent discs were fabricated and segregated into four bonding agent groups of 10 discs each, i.e., GA: Ambar Universal (control), GB: Ambar Universal (4% TiO2 incorporated), GC: G-Premio Bond universal (control), and GD: G-Premio Bond (4% TiO2 incorporated). The bonding agent discs were developed by dispensing the bonding agents into a silicone cast of 5 mm diameter and 1 mm depth. After bonding agent discs were desiccated, the cured discs were weighed and kept in distilled water to be evaluated for water sorption and solubility over 1 year storage period. Statistical analysis was performed by independent variable t-test performed using the IBM SPSS software (Chicago, IL: SPSS Inc). The incorporated bonding agent groups (GA and GB) showed significantly lower (P < 0.05) water sorption and solubility following 1 year of water storage in comparison to the control bonding agents. Both GC and GD demonstrated remarkably lower water sorption and solubility than GA and GB. Incorporation of the colloidal dispersion of TiO2 nanoparticles at 4% by mass into the universal bonding agents has significantly reduced their water sorption and solubility contrast to their control groups.
Collapse
Affiliation(s)
| | - Rafid Jihad Al-Badr
- Department of Restorative Dentistry, College of Dentistry, Ahl Al Bayt University, Karbala, Iraq
| | - Muaid S Abbas Shamash
- Department of Oral Medicine, College of Dentistry, Ahl Al Bayt University, Karbala, Iraq
| |
Collapse
|
7
|
Zarow M, Hardan L, Szczeklik K, Bourgi R, Cuevas-Suárez CE, Jakubowicz N, Nicastro M, Devoto W, Dominiak M, Pytko-Polończyk J, Bereziewicz W, Lukomska-Szymanska M. Porcelain Veneers in Vital vs. Non-Vital Teeth: A Retrospective Clinical Evaluation. Bioengineering (Basel) 2023; 10:bioengineering10020168. [PMID: 36829663 PMCID: PMC9952524 DOI: 10.3390/bioengineering10020168] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/21/2023] [Accepted: 01/26/2023] [Indexed: 01/31/2023] Open
Abstract
Nowadays, the ceramic veneer approach can be considered more predictable than direct composite veneer. To date, there is a lack of studies comparing the clinical performance of anterior veneers cemented on vital teeth (VT) and non-vital teeth (NVT). This longitudinal clinical study investigated the performance of ceramic veneers in VT or anterior NVT. A total of 55 patients were evaluated in the study. Two groups were defined based on the vitality status of the teeth (93 teeth-vital and 61 teeth-non-vital). The United States Public Health Service (USPHS) criteria were used to assess the clinical status. The data were evaluated statistically with the Mann-Whitney U test. All restorations were considered acceptable, and only one veneer in VT failed for the criteria of secondary caries. There were no statistically significant differences in any of the criteria evaluated (p ≤ 0.671). The ceramic veneers evaluated showed a satisfactory clinical performance both in VT and NVT.
Collapse
Affiliation(s)
- Maciej Zarow
- “NZOZ SPS Dentist” Dental Clinic and Postgraduate Course Centre, 30-033 Cracow, Poland
| | - Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
| | - Katarzyna Szczeklik
- Department of Integrated Dentistry, Institute of Dentistry, Faculty of Medicine, Jagiellonian University Medical College, Montelupich 4, 31-155 Krakow, Poland
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut 1107 2180, Lebanon
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, Biomaterials and Bioengineering, 67000 Strasbourg, France
| | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, Circuito Ex Hacienda La Concepción S/N, San Agustín Tlaxiaca 42160, Mexico
- Correspondence: (C.E.C.-S.); (M.L.-S.); Tel.: +52-(771)-72000 (C.E.C.-S.); +48-605-721-200 or +48-426-757-429 (M.L.-S.)
| | - Natalia Jakubowicz
- “NZOZ SPS Dentist” Dental Clinic and Postgraduate Course Centre, 30-033 Cracow, Poland
| | - Marco Nicastro
- “Studio Nicastro” Dental Clinic, Corso Trieste 142, 00198 Roma, Italy
| | | | - Marzena Dominiak
- Department of Dental Surgery, Silesian Piast Medical University, ul. Krakowska 26, 50-425 Wrocław, Poland
| | - Jolanta Pytko-Polończyk
- Department of Integrated Dentistry, Institute of Dentistry, Faculty of Medicine, Jagiellonian University Medical College, Montelupich 4, 31-155 Krakow, Poland
| | - Wioletta Bereziewicz
- Department of Integrated Dentistry, Institute of Dentistry, Faculty of Medicine, Jagiellonian University Medical College, Montelupich 4, 31-155 Krakow, Poland
| | - Monika Lukomska-Szymanska
- Department of General Dentistry, Medical University of Lodz, 251 Pomorska St., 92-213 Lodz, Poland
- Correspondence: (C.E.C.-S.); (M.L.-S.); Tel.: +52-(771)-72000 (C.E.C.-S.); +48-605-721-200 or +48-426-757-429 (M.L.-S.)
| |
Collapse
|
8
|
Ma KSK, Wang LT, Blatz MB. Efficacy of adhesive strategies for restorative dentistry: A systematic review and network meta-analysis of double-blind randomized controlled trials over 12 months of follow-up. J Prosthodont Res 2023; 67:35-44. [PMID: 35691823 DOI: 10.2186/jpr.jpr_d_21_00279] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Abstract
PURPOSE The efficacy of etch-and-rinse, selective enamel-etching, and self-etching protocols for universal adhesives in follow-ups of over 12 months was compared in a network meta-analysis. STUDY SELECTION Randomized controlled trials (RCTs) published from 1998 to 2022 that compared marginal staining, marginal adaptation, retention and fractures, post-operative sensitivity, or recurrence of caries that took place over 12-months post-restoration were selected. A network meta-analysis determined the performance of each adhesive protocol. RESULTS After screening 981 articles, 16 RCTs were subjected to data extraction. Of which, 674 patients with 2816 restorations, were included in the network meta-analysis. The pooled risk of marginal discoloration following self-etching was significantly higher than that following etch-and-rinse at over 12, 24, and 36 months, which was time-dependent. The pooled risks of unfavorable marginal adaptation and unfavorable retention and fractures following self-etching were also significantly higher than that following etch-and-rinse, with the rates of unfavorable retention and fractures in non-carious cervical lesions increasing in a time-dependent manner. The pooled risks of marginal discoloration, unfavorable marginal adaptation, retention and fractures were similar between etch-and-rinse and selective enamel-etching protocols. Post-operative hypersensitivity and recurrence of caries were not significantly different among etch-and-rinse, selective enamel-etching, and self-etching protocols. CONCLUSIONS In follow-ups over 12 months, esthetic and functional outcomes of restorations completed with an etch-and-rinse adhesive protocol were superior to the ones achieved with a self-etching strategy without selective enamel-etching. Selective enamel etching is recommended for self-etching systems. Biological responses were similar for all three adhesive strategies.
Collapse
Affiliation(s)
- Kevin Sheng-Kai Ma
- Center for Global Health, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA.,Department of Epidemiology, Harvard T.H. Chan School of Public Health, Boston, MA.,Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Li-Tzu Wang
- National Taiwan University (NTU) Hospital and College of Medicine, NTU, Taipei, Taiwan
| | - Markus B Blatz
- Department of Preventive and Restorative Sciences, School of Dental Medicine, University of Pennsylvania, Philadelphia, PA
| |
Collapse
|
9
|
Universal Adhesives and Adhesion Modes in Non-Carious Cervical Restorations: 2-Year Randomised Clinical Trial. Polymers (Basel) 2021; 14:polym14010033. [PMID: 35012056 PMCID: PMC8747567 DOI: 10.3390/polym14010033] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/18/2021] [Accepted: 12/20/2021] [Indexed: 11/16/2022] Open
Abstract
This prospective, double-blind, six-arm parallel randomised controlled trial aimed to compare the performance of two universal adhesives (UAs) in non-carious cervical lesions (NCCLs), using the FDI criteria, and analysed if participants/NCCLs’ characteristics influenced the outcome. Thirty-eight 18- to 65-year-old participants were seeking routine dental care at a university clinic. At baseline, 210 NCCLs were randomly allocated to six groups (35 restorations’ each). The UAs tested were FuturabondU (FBU) and AdheseUniversal (ADU) applied in either etch-and-rinse (ER) and self-etch (SE) modes. FuturabondDC (FBDC) in SE and in SE with selective enamel etching (SE-EE) modes were controls. NCCLs were restored with AdmiraFusion. The analysis included nonparametric tests, Kaplan-Meier and log-rank tests (α = 0.05). At 2-years, of 191 restorations, ten were missed due to retention loss (all groups, p > 0.05). FBDC (p = 0.037) and FBU (p = 0.041) performed worse than ADU in SE mode. FBDC and FBU also showed worse functional success rate (p = 0.012, p = 0.007, respectively) and cumulative retention rates (p = 0.022, p = 0.012, respectively) than ADU. Some participants/NCCLs’ characteristics influenced (p < 0.05) the outcomes. FBU did not perform as well as ADU, especially in SE mode and due to functional properties. Participants’ age and NCCLs’ degree of dentin sclerosis and internal shape angle influenced FBU performance.
Collapse
|
10
|
Yazici AR, Uslu Tekce A, Kutuk ZB. Comparative evaluation of different adhesive strategies of a universal adhesive in class II bulk-fill restorations: A 48-month randomized controlled trial. J Dent 2021; 117:103921. [PMID: 34896442 DOI: 10.1016/j.jdent.2021.103921] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 12/05/2021] [Accepted: 12/07/2021] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVES To compare the clinical performance of the universal adhesive used in etch-and-rinse (ER) and self-etch (SE) adhesive strategies for 48-month in class II bulk-fill restorations. METHODS A total of 84 class II bulk-fill resin composite (Tetric EvoCeram Bulk Fill) restorations were placed in 35 participants by one operator using the universal adhesive's (Adhese Universal VivaPen) etch-and-rinse or self-etch mode randomly. The restorations were evaluated by two calibrated examiners at baseline and after 6-, 12-, 24-, 36- and 48-month using modified USPHS criteria. The comparison of the two adhesive strategies for each evaluation criteria was performed with the chi-square test. The baseline scores were compared with those at the recalls using the Friedman and Cochran's Q-test (p < .05). RESULTS At 48-month, 74 restorations were evaluated in 30 participants (recall rate: 85.7%). Marginal discoloration was statistically more frequent in SE approach (p < .05), whereas no significant difference was observed between the two strategies in terms of marginal adaptation (p > .05). There were statistically significant differences between the baseline and 48-month recall in the SE group in terms of marginal adaptation and discoloration (p < .05). In ER group, significant differences were found between baseline and 48-month only for marginal adaptation (p < .05). None of the restorations showed post-operative sensitivity. Secondary caries was observed in one restoration from SE group. CONCLUSIONS The tested bulk-fill restorative exhibited better clinical performance only in terms of marginal discoloration when the universal adhesive was used with ER strategy. CLINICAL RELEVANCE Though ER approach of the tested universal adhesive appears to be advantageous in terms of marginal discoloration, both adhesive strategies had similar impact on the clinical success of bulk-fill resin restorations.
Collapse
Affiliation(s)
- Ayse Ruya Yazici
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey
| | - Aybuke Uslu Tekce
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey
| | - Zeynep Bilge Kutuk
- Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey.
| |
Collapse
|
11
|
Abuelenain DA, Abou Neel EA, Abuhaimed TS, Alamri AM, Ammar HS, Bukhary SMN. Effect of Curcumin Suspension and Vitamin C on Dentin Shear Bond Strength and Durability. A Pilot Study. Open Dent J 2021. [DOI: 10.2174/1874210602115010540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background:
Preserving the strength and durability of dentin bonds is a concern of dental researchers and practitioners.
Objective:
The aim of this study was to investigate the effect of treating etched dentin with vitamin C and curcumin suspension as cross-linking agents on the shear bond strength and durability of a universal dental adhesive.
Methods:
Extracted human third molar teeth were collected. Fifty-six flat coronal dentin surfaces were divided equally into four groups: (1) treated with adhesives; (2) etched with 37% H3PO4 for 10s before application of adhesives; (3) same as group (2), but with dentin treated with 2.5% curcumin suspension for 60s before the application of adhesive; and (4) same as group (3), but with the use of a 20% vitamin C suspension instead of a curcumin suspension. Filtek Z350XT composite was built for all samples. Half of the samples in each group were subjected to thermocycling. Shear bond strength was measured using a universal testing machine. Scanning electron microscopy was used to investigate the dentinal surfaces after treatment.
Results:
Treatment with curcumin suspension preserved immediate and long-term bond strength. Conversely, treatment of etched dentin with vitamin C solution significantly reduced the immediate bond strength, but a significant improvement was observed after aging. SEM showed that both cross-linking agents resulted in narrowing or closing of the dentinal tubules, with an adhesive mode of failure.
Conclusion:
The application of curcumin or vitamin C suspension to acid-etched dentin resulted in different effects on immediate and long-term shear bond strength when using universal adhesives.
Collapse
|
12
|
Rezende M, Martins ACR, da Silva JA, Reis A, de Geus JL. Compliance of randomized controlled trials in posterior restorations with the CONSORT statement: a systematic review of methodology. Clin Oral Investig 2021; 26:41-64. [PMID: 34595606 DOI: 10.1007/s00784-021-04198-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Accepted: 09/21/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES This study aims to investigate the compliance of randomized controlled trials (RCTs) in posterior restorations with the Consolidated Standards of Reporting Trials Statement (CONSORT) statement and to analyze the risk of bias (RoB) of these studies. METHODS A systematic search was performed in PubMed, Scopus, Web of Science, LILACS/BBO, and Cochrane Library. Only RCTs published in peer-reviewed journals were included. The compliance with the CONSORT was evaluated in a 0-2 scale where 0 = no description, 1 = poor description and 2 = adequate description. Descriptive analyses of the CONSORT mean score by journal, country, and RoB were performed. The RoB in RCTs was evaluated by using the Cochrane Collaboration's tool version 1.0. RESULTS A total of 15,476 studies were identified after duplicates removal. O only 202 meet the eligibility criteria, among which 31 were follow-up studies. Concerning the overall RoB, only 29 out of 171 were classified as low risk of bias. The overall mean CONSORT score was 19 ± 5.4 points, which means compliance of approximately 59%. Significant differences among countries, publication period, and RoB were observed (p < 0.001). The journal's impact factor was not correlated with the overall CONSORT score (p = 0.36). CONCLUSIONS The adherence of RCTs conducted in posterior restorations to the CONSORT Statement is still low. In addition, most studies were classified as at unclear risk of bias. These results call up an urgent need for improvement. CLINICAL RELEVANCE Most RCTs conducted in posterior teeth have poor reporting and are mainly classified as having an unclear risk of bias.
Collapse
Affiliation(s)
- Márcia Rezende
- Department of Dentistry, Paulo Picanço School of Dentistry, Joquim Sá, 900, Fortaleza, Ceará, 60135-218, Brazil
| | | | - Jadson Araújo da Silva
- Department of Dentistry, Paulo Picanço School of Dentistry, Joquim Sá, 900, Fortaleza, Ceará, 60135-218, Brazil
| | - Alessandra Reis
- Department of Dentistry, State University of Ponta Grossa, Avenida Carlos Cavalcanti, 4748, Paraná, 84030-900, Brazil
| | - Juliana Larocca de Geus
- Department of Dentistry, Paulo Picanço School of Dentistry, Joquim Sá, 900, Fortaleza, Ceará, 60135-218, Brazil.
| |
Collapse
|
13
|
Badr C, Spagnuolo G, Amenta F, Khairallah C, Mahdi SS, Daher E, Battineni G, Baba NZ, Zogheib T, Qasim SSB, Daher T, Chintalapudi N, Zogheib CM. A Two-Year Comparative Evaluation of Clinical Performance of a Nanohybrid Composite Resin to a Flowable Composite Resin. J Funct Biomater 2021; 12:jfb12030051. [PMID: 34564200 PMCID: PMC8482203 DOI: 10.3390/jfb12030051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 08/31/2021] [Accepted: 09/06/2021] [Indexed: 11/16/2022] Open
Abstract
Objective: This prospective in vivo study aimed to compare the clinical behavior of a flowable composite resin (Genial Universal Flo, GC) and a nanohybrid universal composite resin (Tetric Evo Ceram, Ivoclar Vivadent) used in Class I and II direct esthetic restorations in posterior teeth. Methods: A total of 108 Class I and II direct restorations were performed in patients aged between 20 and 60 years. The originality of this study lies in the fact that both materials were placed in pairs, in the same clinical environment (i.e., the same patient and the same type of tooth). The evaluations were performed now of restoration and after 2-weeks, 6-, 12-, and 24-months intervals using clinical examination, clinical photographs, and radiological examination, according to modified USPHS criteria. Statistical analysis was performed using the Fisher exact test and chi-square analysis. Results: At baseline, the universal composite resin showed better esthetic properties such as surface luster, surface staining marginal staining. Both materials regressed significantly over time with no significant difference between groups. Conclusions: Both flowable and nanohybrid composite resins exhibit acceptable clinical performance. The present 24 months of evaluation of different composites showed that the G-ænial Universal Flo could be an effective esthetic material for posterior restoration. No significant difference between both materials over time concerning surface luster, surface staining, and marginal staining.
Collapse
Affiliation(s)
- Carelle Badr
- Department of Esthetic and Restorative Dentistry, School of Dentistry, Saint Joseph University of Beirut, Beirut 1004 2020, Lebanon; (C.B.); (C.K.); (E.D.); (T.D.); (C.M.Z.)
| | - Gianrico Spagnuolo
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples “Federico II”, 80131 Napoli, Italy
- Institute of Dentistry, I. M. Sechenov First Moscow State Medical University, 119435 Moscow, Russia
- Correspondence:
| | - Francesco Amenta
- Center of Clinical Research, Telemedicine & Telepharmacy Department, School of Medicinal and Health Products Sciences, University of Camerino, 62032 Camerino, Italy; (F.A.); (S.S.M.); (G.B.); (N.C.)
| | - Carlos Khairallah
- Department of Esthetic and Restorative Dentistry, School of Dentistry, Saint Joseph University of Beirut, Beirut 1004 2020, Lebanon; (C.B.); (C.K.); (E.D.); (T.D.); (C.M.Z.)
| | - Syed Sarosh Mahdi
- Center of Clinical Research, Telemedicine & Telepharmacy Department, School of Medicinal and Health Products Sciences, University of Camerino, 62032 Camerino, Italy; (F.A.); (S.S.M.); (G.B.); (N.C.)
- Department of Community Dentistry, Jinnah Medical and Dental College, Sohail University, Karachi 74800, Pakistan
| | - Elie Daher
- Department of Esthetic and Restorative Dentistry, School of Dentistry, Saint Joseph University of Beirut, Beirut 1004 2020, Lebanon; (C.B.); (C.K.); (E.D.); (T.D.); (C.M.Z.)
| | - Gopi Battineni
- Center of Clinical Research, Telemedicine & Telepharmacy Department, School of Medicinal and Health Products Sciences, University of Camerino, 62032 Camerino, Italy; (F.A.); (S.S.M.); (G.B.); (N.C.)
| | - Nadim Z. Baba
- Advanced Specialty Education Program in Implant Dentistry, School of Dentistry, Loma Linda University, Loma Linda, CA 92354, USA;
| | - Tatiana Zogheib
- Department of Orthodontics and Dentofacial Orthopedics, International University of Catalunya, 08017 Sant Cugat del Vallés, Barcelona, Spain;
| | | | - Tony Daher
- Department of Esthetic and Restorative Dentistry, School of Dentistry, Saint Joseph University of Beirut, Beirut 1004 2020, Lebanon; (C.B.); (C.K.); (E.D.); (T.D.); (C.M.Z.)
| | - Nalini Chintalapudi
- Center of Clinical Research, Telemedicine & Telepharmacy Department, School of Medicinal and Health Products Sciences, University of Camerino, 62032 Camerino, Italy; (F.A.); (S.S.M.); (G.B.); (N.C.)
| | - Carina Mehanna Zogheib
- Department of Esthetic and Restorative Dentistry, School of Dentistry, Saint Joseph University of Beirut, Beirut 1004 2020, Lebanon; (C.B.); (C.K.); (E.D.); (T.D.); (C.M.Z.)
| |
Collapse
|
14
|
de Freitas BN, Pintado-Palomino K, de Almeida CVVB, Cruvinel PB, Souza-Gabriel AE, Corona SAM, Geraldeli S, Grosgogeat B, Roulet JF, Tirapelli C. Clinical decision-making in anterior resin composite restorations: a multicenter evaluation. J Dent 2021; 113:103757. [PMID: 34333053 DOI: 10.1016/j.jdent.2021.103757] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/23/2021] [Accepted: 07/25/2021] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE This study investigated whether a sample of anterior resin composite restorations could be differently evaluated in different centers of evaluation by clinical and lay evaluators. METHODS Anterior resin composite restorations on high-quality intraoral digital photography were evaluated using FDI criteria (1-5 score) by pairs of clinical and lay evaluators in Brazil (BR), France (FR), Peru (PE), and the United States of America (USA). Scores were allocated as maintenance (1, 2, 3), repair (4) and replacement (5) when comparing clinical evaluators and, as acceptable (1, 2, 3) and unacceptable (4, 5) when comparing clinical vs. lay evaluators and lay vs. lay evaluators. The Chi-square test compared the frequencies of scores among the centers. RESULTS The frequencies of maintaining, repairing, or replacing anterior resin composite restorations given by clinical evaluators varied depending on the evaluation center. BR and PE showed the highest frequencies for repair and replacement, while FR and USA showed the highest frequencies for maintenance. The comparison of frequencies of anterior resin composite restorations accepted or unaccepted by the clinical vs lay evaluators in the same centers showed a significantly higher frequency of acceptable dental restorations coming from clinical evaluators. Comparison between lay evaluators from different centers showed significant higher frequency of unacceptable dental restorations by BR, compared to other centers. CONCLUSIONS In the evaluation of anterior resin composite restorations, the maintenance, repair, or replacement trends can vary among different centers. The unacceptable rate came more frequently from lay than from clinical evaluators. Lay evaluators from different centers differed significantly. CLINICAL SIGNIFICANCE Clinical and lay evaluators in distant evaluation centers can present different trends when assessing anterior resin composite restoration. Multicenter evaluations can help to understand such differences and it is important because clinical decision-making based on scientific evidence comes from clinical studies done in different research centers.
Collapse
Affiliation(s)
- Bruna Neves de Freitas
- Department of Dental Materials and Prosthodontics, University of São Paulo, Ribeirão Preto, Brazil.
| | | | | | - Pedro Bastos Cruvinel
- Department of Dental Materials and Prosthodontics, University of São Paulo, Ribeirão Preto, Brazil.
| | | | | | - Saulo Geraldeli
- Department of General Dentistry, East Carolina University, Greenville, USA.
| | - Brigitte Grosgogeat
- Faculté d'Odontologie, UMR CNRS 5615, Université de Lyon, Lyon, France; Pôle d'Odontologie, Hospices Civils de Lyon, Lyon, France.
| | - Jean-François Roulet
- Department of Restorative Dental Science, University of Florida, Gainesville, USA.
| | - Camila Tirapelli
- Department of Dental Materials and Prosthodontics, University of São Paulo, Ribeirão Preto, Brazil.
| |
Collapse
|
15
|
Sabbagh J, El Masri L, Fahd JC, Nahas P. A three-year randomized clinical trial evaluating direct posterior composite restorations placed with three self-etch adhesives. Biomater Investig Dent 2021; 8:92-103. [PMID: 34240061 PMCID: PMC8238063 DOI: 10.1080/26415275.2021.1939034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Aim To compare the clinical performance of composite restorations placed with a universal adhesive, one-step and two-step self-etch adhesives in class I and II posterior cavities. Materials and methods In this in vivo study, 46 volunteers presenting with at least three carious lesions were included. Each participant received the three restorative systems: universal adhesive/nanofilled composite (Scotchbond Universal/Filtek Z350 XT: SBU/FZXT), one-step self-etch adhesive/microhybrid composite (G-aenial bond/G-aenial Posterior: GB/GP) and the two-step self-etch adhesive/nanohybrid composite (OptiBond XTR/Herculite Ultra: OBX/HU). The adhesives were all placed in self-etch mode. In total, 138 restorations were evaluated at baseline and at 6,12 and 36 months using the modified United States Public Health Service criteria. Data were analysed using Kruskal-Wallis, Mann-Whitney U, Friedman and Wilcoxon non-parametric tests (p < .05). Ninety-one restorations were evaluated at 36 months. Results Seven restorations, three SBU/FZXT, three GB/GP and one OBX/HU failed during this study. The reasons for failure were marginal fracture and secondary caries. SBU/FZXT restorations showed significant marginal deterioration in all parameters. Overall success rates were: 93.5% (SBU/FZXT), 96.6% (GB/GP) and 96.8% (OBX/HU). Conclusions After three years, the three restorative systems have comparable clinical effectiveness and success rates, except for the marginal integrity, that was suboptimal for both the SBU/FZXT and GB/GP restorations in comparison to the OBX/HU restorations.
Collapse
Affiliation(s)
- Joseph Sabbagh
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Layal El Masri
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Jean Claude Fahd
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| | - Paul Nahas
- Department of Restorative and aesthetic dentistry and Endodontics, Faculty of Dental Medicine, Lebanese University, Beirut, Lebanon
| |
Collapse
|
16
|
Effect of 940 nm laser diode irradiation prior to bonding procedure on postoperative sensitivity following class II composite restorations: a split-mouth randomized clinical trial. Lasers Med Sci 2021; 36:1109-1116. [PMID: 33392782 DOI: 10.1007/s10103-020-03213-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 11/26/2020] [Indexed: 10/22/2022]
Abstract
The aim of this study was to evaluate the effect of 940 nm laser diode on class II composite cavities prior to bonding and restoration process on the postoperative sensitivity (POS). Thirty patients with two bilateral premolars with mesio or disto-occlusal carious lesions were evaluated. In each patient, the teeth were randomly divided into the control and laser groups. After cavity preparation and isolation and before the bonding process, the laser group was subjected to 940 nm irradiation (Epic 10, Biolase, USA) by 400 μ tip continuously at 100 mW with 398 J/cm2 energy density of tip, which was applied for 5 s at a distance of 2 mm on the axial wall of the cavity. In the control group, irradiation was performed by using the aiming beam. Access cavity was then restored with a composite resin. Cold sensitivity was measured using a cold spray application on the middle third of teeth buccal surface at baseline (before the intervention), 1, 14, and 30 days after the restoration by visual analog scale (VAS) criteria. The mean Friedman and Wilcoxon signed-rank tests were used for data analysis. It was shown that in both laser and control groups, the VAS was significantly decreased at all times compared to the baseline (p ≤ 0.05). There was no statistically significant difference between the mean VAS of two groups at baseline and first day (p ≤ 0.05), but at 14 and 30 days after the intervention, it was significantly lower in the laser group (p ≤ 0.05). The results of this study demonstrated that the cavity pretreatment with laser diode (940 nm) effectively reduces the postoperative sensitivity in class II composite restorations.
Collapse
|
17
|
Wawrzynkiewicz A, Rozpedek-Kaminska W, Galita G, Lukomska-Szymanska M, Lapinska B, Sokolowski J, Majsterek I. The Cytotoxicity and Genotoxicity of Three Dental Universal Adhesives-An In Vitro Study. Int J Mol Sci 2020; 21:ijms21113950. [PMID: 32486393 PMCID: PMC7312029 DOI: 10.3390/ijms21113950] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Revised: 05/23/2020] [Accepted: 05/29/2020] [Indexed: 12/16/2022] Open
Abstract
Dental universal adhesives are considered an useful tool in modern dentistry as they can be used in different etching techniques, allow for simplified protocol and provide sufficient bond strength. However, there is still no consensus as to their toxicity towards pulp. Thus, the present study aimed to evaluate the cytotoxicity and genotoxicity of three universal adhesives: OptiBond Universal, Prime&Bond Universal and Adhese in an in vitro experimental model, monocyte/macrophage cell line SC (ATCC CRL-9855). The cytotoxicity was measured by means of XTT assay, whereas the genotoxicity (comet assay) was evaluated based on the percentage of DNA present in the comet tail. Furthermore, the ability of the adhesives to induce apoptosis was analyzed using flow cytometry (FC) with the FITC annexin V/propidium iodide (PI) double staining. The analysis of the cell cycle progression was performed with FC using PI staining. OptiBond Universal presented significant, while Prime&Bond Universal and Adhese Universal had minimal cytotoxicity and genotoxicity towards human SC cells. Moreover, only OptiBond Universal increased the level of apoptosis in SC cell line. None of the adhesives showed significant cell cycle arrest, as revealed by FC analysis. Due to substantial differences in toxicity in in vitro studies of dental adhesives, there is a great need for further research in order to establish more reliable test protocols allowing for standardized methodology.
Collapse
Affiliation(s)
- Adam Wawrzynkiewicz
- Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland; (A.W.); (W.R.-K.); (G.G.)
| | - Wioletta Rozpedek-Kaminska
- Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland; (A.W.); (W.R.-K.); (G.G.)
| | - Grzegorz Galita
- Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland; (A.W.); (W.R.-K.); (G.G.)
| | - Monika Lukomska-Szymanska
- Department of General Dentistry, Medical University of Lodz, 90-419 Lodz, Poland; (M.L.-S.); (B.L.); (J.S.)
| | - Barbara Lapinska
- Department of General Dentistry, Medical University of Lodz, 90-419 Lodz, Poland; (M.L.-S.); (B.L.); (J.S.)
| | - Jerzy Sokolowski
- Department of General Dentistry, Medical University of Lodz, 90-419 Lodz, Poland; (M.L.-S.); (B.L.); (J.S.)
| | - Ireneusz Majsterek
- Department of Clinical Chemistry and Biochemistry, Medical University of Lodz, 90-419 Lodz, Poland; (A.W.); (W.R.-K.); (G.G.)
- Correspondence: ; Tel.: +48-42-272-53-00
| |
Collapse
|