1
|
Cao J, Yuan C, Zhang Y, Quan Y, Chang P, Yang J, Song Q, Miao Y. Observation of intracranial artery and venous sinus hemodynamics using compressed sensing-accelerated 4D flow MRI: performance at different acceleration factors. Front Neurosci 2024; 18:1438003. [PMID: 39119457 PMCID: PMC11306029 DOI: 10.3389/fnins.2024.1438003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2024] [Accepted: 07/11/2024] [Indexed: 08/10/2024] Open
Abstract
Objective To investigate the feasibility and performance of 4D flow MRI accelerated by compressed sensing (CS) for the hemodynamic quantification of intracranial artery and venous sinus. Materials and methods Forty healthy volunteers were prospectively recruited, and 20 volunteers underwent 4D flow MRI of cerebral artery, and the remaining volunteers underwent 4D flow MRI of venous sinus. A series of 4D flow MRI was acquired with different acceleration factors (AFs), including sensitivity encoding (SENSE, AF = 4) and CS (AF = CS4, CS6, CS8, and CS10) at a 3.0 T MRI scanner. The hemodynamic parameters, including flow rate, mean velocity, peak velocity, max axial wall shear stress (WSS), average axial WSS, max circumferential WSS, average circumferential WSS, and 3D WSS, were calculated at the internal carotid artery (ICA), transverse sinus (TS), straight sinus (SS), and superior sagittal sinus (SSS). Results Compared to the SENSE4 scan, for the left ICA C2, mean velocity measured by CS8 and CS10 groups, and 3D WSS measured by CS6, CS8, and CS10 groups were underestimated; for the right ICA C2, mean velocity measured by CS10 group, and 3D WSS measured by CS8 and CS10 groups were underestimated; for the right ICA C4, mean velocity measured by CS10 group, and 3D WSS measured by CS8 and CS10 groups were underestimated; and for the right ICA C7, mean velocity and 3D WSS measured by CS8 and CS10 groups, and average axial WSS measured by CS8 group were also underestimated (all p < 0.05). For the left TS, max axial WSS and 3D WSS measured by CS10 group were significantly underestimated (p = 0.032 and 0.003). Similarly, for SS, mean velocity, peak velocity, average axial WSS measured by the CS8 and CS10 groups, max axial WSS measured by CS6, CS8, and CS10 groups, and 3D WSS measured by CS10 group were significantly underestimated compared to the SENSE4 scan (p = 0.000-0.021). The hemodynamic parameters measured by CS4 group had only minimal bias and great limits of agreement compared to conventional 4D flow (SENSE4) in the ICA and every venous sinus (the max/min upper limit to low limit of the 95% limits of agreement = 11.4/0.03 to 0.004/-5.7, 14.4/0.05 to -0.03/-9.0, 12.6/0.04 to -0.03/-9.4, 16.8/0.04 to 0.6/-14.1; the max/min bias = 5.0/-1.2, 3.5/-1.4, 4.5/-1.1, 6.6/-4.0 for CS4, CS6, CS8, and CS10, respectively). Conclusion CS4 strikes a good balance in 4D flow between flow quantifications and scan time, which could be recommended for routine clinical use.
Collapse
Affiliation(s)
| | | | | | | | | | | | | | - Yanwei Miao
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| |
Collapse
|
2
|
Rooijakkers MJP, El Messaoudi S, Stens NA, van Wely MH, Habets J, Brink M, Rodwell L, Giese D, van der Geest RJ, van Royen N, Nijveldt R. Assessment of paravalvular regurgitation after transcatheter aortic valve replacement using 2D multi-velocity encoding and 4D flow cardiac magnetic resonance. Eur Heart J Cardiovasc Imaging 2024; 25:929-936. [PMID: 38306632 PMCID: PMC11210991 DOI: 10.1093/ehjci/jeae035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Accepted: 01/26/2024] [Indexed: 02/04/2024] Open
Abstract
AIMS To compare the novel 2D multi-velocity encoding (venc) and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS In this prospective study, patients underwent CMR 1 month after TAVR for the assessment of PVR, for which 2D multi-venc and 4D flow were used, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age ± SD 80 ± 5 years, 9 men). The mean RF was 11.7 ± 10.0% when standard 2D flow was used, 10.6 ± 7.0% when 2D multi-venc flow was used, and 9.6 ± 7.3% when 4D flow was used. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, P < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, P < 0.001). Bland-Altman plots revealed no substantial bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra-observer and inter-observer reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively, and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION Two-dimensional multi-venc and 4D flow produce an accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.
Collapse
Affiliation(s)
- Maxim J P Rooijakkers
- Department of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - Saloua El Messaoudi
- Department of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - Niels A Stens
- Department of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
- Department of Medical BioSciences, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Marleen H van Wely
- Department of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - Jesse Habets
- Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
- Department of Radiology and Nuclear Medicine, Haaglanden Medical Centre, The Hague, The Netherlands
| | - Monique Brink
- Department of Radiology and Nuclear Medicine, Radboud University Medical Centre, Nijmegen, The Netherlands
| | - Laura Rodwell
- Department of Health Sciences, Section Biostatistics, Radboud Institute for Health Sciences, Nijmegen, The Netherlands
| | - Daniel Giese
- Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany
- Institute of Radiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), University Hospital Erlangen, Erlangen, Germany
| | - Rob J van der Geest
- Department of Medical Imaging, Leiden University Medical Centre, Leiden, The Netherlands
| | - Niels van Royen
- Department of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| | - Robin Nijveldt
- Department of Cardiology, Radboud University Medical Centre, Geert Grooteplein Zuid 10, 6525 GA, Nijmegen, The Netherlands
| |
Collapse
|
3
|
Zhang J, Tang X, Xiong Z, Tian D, Hu S, He Y, Song Q, Fang M, Li Z. Evaluation of Left Ventricular Flow Kinetic Energy by Four-Dimensional Blood Flow MRI in Nondialysis Chronic Kidney Disease Patients. J Magn Reson Imaging 2024. [PMID: 38708838 DOI: 10.1002/jmri.29435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 04/21/2024] [Accepted: 04/22/2024] [Indexed: 05/07/2024] Open
Abstract
BACKGROUND Chronic kidney disease (CKD) is associated with increased, and early cardiovascular disease risk. Changes in hemodynamics within the left ventricle (LV) respond to cardiac remodeling. The LV hemodynamics in nondialysis CKD patients are not clearly understood. PURPOSE To use four-dimensional blood flow MRI (4D flow MRI) to explore changes in LV kinetic energy (KE) and the relationship between LV KE and LV remodeling in CKD patients. STUDY TYPE Retrospective. POPULATION 98 predialysis CKD patients (Stage 3: n = 21, stage 4: n = 21, and stage 5: n = 56) and 16 age- and sex-matched healthy controls. FIELD STRENGTH/SEQUENCE 3.0 T/balanced steady-state free precession (SSFP) cine sequence, 4D flow MRI with a fast field echo sequence, T1 mapping with a modified Look-Locker SSFP sequence, and T2 mapping with a gradient recalled and spin echo sequence. ASSESSMENT Demographic characteristics (age, sex, height, weight, blood pressure, heart rate, aortic regurgitation, and mitral regurgitation) and laboratory data (eGFR, Creatinine, hemoglobin, ferritin, transferrin saturation, potassium, and carbon dioxide bonding capacity) were extracted from patient records. Myocardial T1, T2, LV ejection fraction, end diastolic volume (EDV), end systolic volume, LV flow components (direct flow, delayed ejection, retained inflow, and residual volume) and KE parameters (peak systolic, systolic, diastolic, peak E-wave, peak A-wave, E/A ratio, and global) were assessed. The KE parameters were normalized to EDV (KEiEDV). Parameters were compared between disease stage in CKD patients, and between CKD patients and healthy controls. STATISTICAL TESTS Differences in clinical and imaging parameters between groups were compared using one-way ANOVA, Kruskal Walls and Mann-Whitney U tests, chi-square test, and Fisher's exact test. Pearson or Spearman's correlation coefficients and multiple linear regression analysis were used to compare the correlation between LV KE and other clinical and functional parameters. A P-value of <0.05 was considered significant. RESULTS Compared with healthy controls, peak systolic (24.76 ± 5.40 μJ/mL vs. 31.86 ± 13.18 μJ/mL), systolic (11.62 ± 2.29 μJ/mL vs. 15.27 ± 5.10 μJ/mL), diastolic (7.95 ± 1.92 μJ/mL vs. 13.33 ± 5.15 μJ/mL), peak A-wave (15.95 ± 4.86 μJ/mL vs. 31.98 ± 14.51 μJ/mL), and global KEiEDV (9.40 ± 1.64 μJ/mL vs. 14.02 ± 4.14 μJ/mL) were significantly increased and the KEiEDV E/A ratio (1.16 ± 0.67 vs. 0.69 ± 0.53) was significantly decreased in CKD patients. As the CKD stage progressed, both diastolic KEiEDV (10.45 ± 4.30 μJ/mL vs. 12.28 ± 4.85 μJ/mL vs. 14.80 ± 5.06 μJ/mL) and peak E-wave KEiEDV (15.30 ± 7.06 μJ/mL vs. 14.69 ± 8.20 μJ/mL vs. 19.33 ± 8.29 μJ/mL) increased significantly. In multiple regression analysis, global KEiEDV (β* = 0.505; β* = 0.328), and proportion of direct flow (β* = -0.376; β* = -0.410) demonstrated an independent association with T1 and T2 times. DATA CONCLUSION 4D flow MRI-derived LV KE parameters show altered LV adaptations in CKD patients and correlate independently with T1 and T2 mapping that may represent myocardial fibrosis and edema. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY Stage 3.
Collapse
Affiliation(s)
- Jingyu Zhang
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Xiangyu Tang
- Department of Nephrology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Ziqi Xiong
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Di Tian
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Shuai Hu
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yifan He
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Qingwei Song
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Ming Fang
- Department of Nephrology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Zhiyong Li
- Department of Radiology, The First Affiliated Hospital of Dalian Medical University, Dalian, China
| |
Collapse
|
4
|
Aono S, Tsuneta S, Nishioka N, Aoike T, Hirayama H, Ishizaka K, Kwon J, Yoneyama M, Fujima N, Kudo K. Comparison of Echo-Planar Imaging and Compressed Sensing in the Estimation of Flow Metrics from Aortic 4D Flow MR Imaging: A Healthy Volunteer Study. Magn Reson Med Sci 2024:mp.2023-0011. [PMID: 38556273 DOI: 10.2463/mrms.mp.2023-0011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/02/2024] Open
Abstract
PURPOSE Prolonged scanning of time-resolved 3D phase-contrast MRI (4D flow MRI) limits its routine use in clinical practice. An echo-planar imaging (EPI)-based sequence and compressed sensing can reduce the scan duration. We aimed to determine the impact of EPI for 4D flow MRI on the scan duration, image quality, and quantitative flow metrics. METHODS This was a prospective study of 15 healthy volunteers (all male, mean age 33 ± 5 years). Conventional sensitivity encoding (SENSE), EPI with SENSE (EPI), and compressed SENSE (CS) (reduction factors: 6 and 12, respectively) were scanned.Scan duration, qualitative indexes of image quality, and quantitative flow parameters of net flow volume, maximum flow velocity, wall shear stress (WSS), and energy loss (EL) in the ascending aorta were assessed. Two-dimensional phase-contrast cine MRI (2D-PC) was considered the gold standard of net flow volume and maximum flow velocity. RESULTS Compared to SENSE, EPI and CS12 shortened scan durations by 71% and 73% (EPI, 4 min 39 sec; CS6, 7 min 29 sec; CS12, 4 min 14 sec; and SENSE, 15 min 51 sec). Visual image quality was significantly better for EPI than for SENSE and CS (P < 0.001). The net flow volumes obtained with SENSE, EPI, and CS12 and those obtained with 2D-PC were correlated well (r = 0.950, 0.871, and 0.850, respectively). However, the maximum velocity obtained with EPI was significantly underestimated (P < 0.010). The average WSS was significantly higher with EPI than with SENSE, CS6, and CS12 (P < 0.001, P = 0.040, and P = 0.012, respectively). The EL was significantly lower with EPI than with CS6 and CS12 (P = 0.002 and P = 0.007, respectively). CONCLUSION EPI reduced the scan duration, improved visual image quality, and was associated with more accurate net flow volume than CS. However, the flow velocity, WSS, and EL values obtained with EPI and other sequences may not be directly comparable.
Collapse
Affiliation(s)
- Satoru Aono
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Noriko Nishioka
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Takuya Aoike
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Hiroyuki Hirayama
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Kinya Ishizaka
- Department of Radiological Technology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | | | | | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Hokkaido, Japan
| | - Kohsuke Kudo
- Department of Diagnostic Imaging, Hokkaido University Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
- Global Center for Biomedical Science and Engineering, Faculty of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| |
Collapse
|
5
|
Nallamothu T, Pradella M, Markl M, Greenland P, Passman R, Elbaz MS. Robust and fast stochastic 4D flow vector-field signature technique for quantifying composite flow dynamics from 4D flow MRI: Application to left atrial flow in atrial fibrillation. Med Image Anal 2024; 92:103065. [PMID: 38113616 DOI: 10.1016/j.media.2023.103065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 11/09/2023] [Accepted: 12/11/2023] [Indexed: 12/21/2023]
Abstract
4D flow MRI is an emerging imaging modality that maps voxel-wise blood flow information as velocity vector fields that is acquired in 7-dimensional image volumes (3 spatial dimensions + 3 velocity directions + time). Blood flow in the cardiovascular system is often complex and composite involving multiple flow dynamics and patterns (e.g., vortex flow, jets, stagnating flow) that occur and interact simultaneously. The spectrum of such complex flow dynamics is embedded in the velocity vector field dynamics derived from 4D Flow MRI. However, current flow metrics cannot fully measure high-dimensional vector-field data and embedded complex composite flow data. Instead, these methods need to break down the vector-field data into secondary scalar fields of individual flow components using fluid dynamics operators. These methods are gradient-based and sensitive to data uncertainties, and only focus on individual flow components of the overall composite flow, therefore potentially underestimating the severity of overall flow changes associated with cardiovascular diseases. To address these limitations, in MICCAI 2021, we introduced a novel comprehensive stochastic 4D Flow vector-field signature technique that works directly on the entire spatiotemporal velocity vector field. This technique uses efficient stochastic gradient-free interrogation of multi-million flow vector-pairs per patient to derive the patient's unique flow profile of the complex composite flow alterations and in real-time processing. The signature technique's probabilistic gradient-free formulation should allow for highly robust quantification despite inherent errors in 4D flow MRI acquisitions. Here, we extend the application of the 4D flow vector-field signature technique to the left atrium to analyze complex composite flow changes in patients with atrial fibrillation. In 128 subjects, we performed extensive sensitivity testing and determined that the vector-field signature technique is highly robust to typical sources of data uncertainties in 4D flow MRI: degradation in spatiotemporal resolution, added Gaussian noise, and segmentation errors. We demonstrate the excellent generalizability of the stochastic convergence from the aorta to the left atrium and between different 4D Flow MRI acquisition protocols. We compare the robustness of our technique to existing advanced flow quantification metrics of kinetic energy, vorticity, and energy loss demonstrating a superior performance of up-to 14-fold. Our results show the potential diagnostic and clinical utility of our signature technique in identifying distinctly altered composite flow signatures in atrial fibrillation patients independent of existing flow metrics.
Collapse
Affiliation(s)
- Thara Nallamothu
- Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Biomedical Engineering, Northwestern University, Evanston, IL, United States
| | - Maurice Pradella
- Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Department of Radiology, Clinic of Radiology and Nuclear Medicine, University Hospital of Basel, Basel, Switzerland
| | - Michael Markl
- Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States; Biomedical Engineering, Northwestern University, Evanston, IL, United States
| | - Philip Greenland
- Department of Preventive Medicine, Northwestern University Feinberg School of Medicine, Chicago, IL, United States
| | - Rod Passman
- Cardiology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States
| | - Mohammed Sm Elbaz
- Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, United States.
| |
Collapse
|
6
|
Ebrahimkhani M, Johnson EMI, Sodhi A, Robinson JD, Rigsby CK, Allen BD, Markl M. A Deep Learning Approach to Using Wearable Seismocardiography (SCG) for Diagnosing Aortic Valve Stenosis and Predicting Aortic Hemodynamics Obtained by 4D Flow MRI. Ann Biomed Eng 2023; 51:2802-2811. [PMID: 37573264 DOI: 10.1007/s10439-023-03342-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Accepted: 07/27/2023] [Indexed: 08/14/2023]
Abstract
In this paper, we explored the use of deep learning for the prediction of aortic flow metrics obtained using 4-dimensional (4D) flow magnetic resonance imaging (MRI) using wearable seismocardiography (SCG) devices. 4D flow MRI provides a comprehensive assessment of cardiovascular hemodynamics, but it is costly and time-consuming. We hypothesized that deep learning could be used to identify pathological changes in blood flow, such as elevated peak systolic velocity ([Formula: see text]) in patients with heart valve diseases, from SCG signals. We also investigated the ability of this deep learning technique to differentiate between patients diagnosed with aortic valve stenosis (AS), non-AS patients with a bicuspid aortic valve (BAV), non-AS patients with a mechanical aortic valve (MAV), and healthy subjects with a normal tricuspid aortic valve (TAV). In a study of 77 subjects who underwent same-day 4D flow MRI and SCG, we found that the [Formula: see text] values obtained using deep learning and SCGs were in good agreement with those obtained by 4D flow MRI. Additionally, subjects with non-AS TAV, non-AS BAV, non-AS MAV, and AS could be classified with ROC-AUC (area under the receiver operating characteristic curves) values of 92%, 95%, 81%, and 83%, respectively. This suggests that SCG obtained using low-cost wearable electronics may be used as a supplement to 4D flow MRI exams or as a screening tool for aortic valve disease.
Collapse
Affiliation(s)
- Mahmoud Ebrahimkhani
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Ethan M I Johnson
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Aparna Sodhi
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
| | - Joshua D Robinson
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Cynthia K Rigsby
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
- Ann & Robert H. Lurie Children's Hospital, Chicago, IL, 60611, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Bradly D Allen
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA.
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, 60208, USA.
| |
Collapse
|
7
|
Sodhi A, Markl M, Popescu AR, Griffin LM, Robinson JD, Rigsby CK. Highly accelerated compressed sensing 4D flow MRI in congenital and acquired heart disease: comparison of aorta and main pulmonary artery flow parameters with conventional 4D flow MRI in children and young adults. Pediatr Radiol 2023; 53:2597-2607. [PMID: 37882844 DOI: 10.1007/s00247-023-05788-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 09/19/2023] [Accepted: 09/28/2023] [Indexed: 10/27/2023]
Abstract
BACKGROUND Four-dimensional flow (4D flow) MRI has become a clinically utilized cardiovascular flow assessment tool. However, scans can be lengthy and may require anesthesia in younger children. Adding compressed sensing can decrease scan time, but its impact on hemodynamic data accuracy needs additional assessment. OBJECTIVE To compare 4D flow hemodynamics acquired with and without compressed sensing. MATERIALS AND METHODS Twenty-seven patients (median age: 13 [IQR: 9.5] years) underwent conventional and compressed sensing cardiovascular 4D flow following informed consent. Conventional 4D flow was performed using parallel imaging and an acceleration factor of 2. Compressed sensing 4D flow was performed with an acceleration factor of 7.7. Regions of interest were placed to compare flow parameters in the ascending aorta and main pulmonary artery. Paired Student's t-tests, Wilcoxon signed-rank tests, Bland-Altman plots, and intraclass correlation coefficients were conducted. A P-value of < 0.05 was considered statistically significant. RESULTS Mean scan acquisition time was reduced by 59% using compressed sensing (3.4 vs. 8.2 min, P < 0.001). Flow quantification was similar for compressed sensing and conventional 4D flow for the ascending aorta net flow: 47 vs. 49 ml/beat (P = 0.28); forward flow: 49 vs. 50 ml/beat (P = 0.07), and main pulmonary artery net flow: 49 vs. 51 ml/beat (P = 0.18); forward flow: 50 vs. 55 ml/beat (P = 0.07). Peak systolic velocity was significantly underestimated by compressed sensing 4D flow in the ascending aorta: 114 vs. 128 cm/s (P < 0.001) and main pulmonary artery: 106 vs. 112 cm/s (P = 0.02). CONCLUSION For both the aorta and main pulmonary artery, compressed sensing 4D flow provided equivalent net and forward flow values compared to conventional 4D flow but underestimated peak systolic velocity. By reducing scan time, compressed sensing 4D flow may decrease the need for anesthesia and increase scanner output without significantly compromising data integrity.
Collapse
Affiliation(s)
- Aparna Sodhi
- Department of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, 225 East Chicago Avenue #9, Chicago, IL, 60611, USA.
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
- Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL, USA
| | - Andrada R Popescu
- Department of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, 225 East Chicago Avenue #9, Chicago, IL, 60611, USA
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Lindsay M Griffin
- Department of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, 225 East Chicago Avenue #9, Chicago, IL, 60611, USA
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Joshua D Robinson
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
- Division of Cardiology, Ann and Robert H. Lurie Children's Hospital of Chicago, Chicago, IL, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Cynthia K Rigsby
- Department of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, 225 East Chicago Avenue #9, Chicago, IL, 60611, USA
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
- Department of Pediatrics, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| |
Collapse
|
8
|
Panda A, Francois CJ, Bookwalter CA, Chaturvedi A, Collins JD, Leiner T, Rajiah PS. Non-Contrast Magnetic Resonance Angiography: Techniques, Principles, and Applications. Magn Reson Imaging Clin N Am 2023; 31:337-360. [PMID: 37414465 DOI: 10.1016/j.mric.2023.04.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/08/2023]
Abstract
Several non-contrast magnetic resonance angiography (MRA) techniques have been developed, providing an attractive alternative to contrast-enhanced MRA and a radiation-free alternative to computed tomography (CT) CT angiography. This review describes the physical principles, limitations, and clinical applications of bright-blood (BB) non-contrast MRA techniques. The principles of BB MRA techniques can be broadly divided into (a) flow-independent MRA, (b) blood-inflow-based MRA, (c) cardiac phase dependent, flow-based MRA, (d) velocity sensitive MRA, and (e) arterial spin-labeling MRA. The review also includes emerging multi-contrast MRA techniques that provide simultaneous BB and black-blood images for combined luminal and vessel wall evaluation.
Collapse
Affiliation(s)
- Ananya Panda
- Department of Radiology, All India Institute of Medical Sciences, Jodhpur, India
| | | | | | - Abhishek Chaturvedi
- Department of Radiology, University of Rochester Medical Center, Rochester, NY, USA
| | | | - Tim Leiner
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | |
Collapse
|
9
|
Bissell MM, Raimondi F, Ait Ali L, Allen BD, Barker AJ, Bolger A, Burris N, Carhäll CJ, Collins JD, Ebbers T, Francois CJ, Frydrychowicz A, Garg P, Geiger J, Ha H, Hennemuth A, Hope MD, Hsiao A, Johnson K, Kozerke S, Ma LE, Markl M, Martins D, Messina M, Oechtering TH, van Ooij P, Rigsby C, Rodriguez-Palomares J, Roest AAW, Roldán-Alzate A, Schnell S, Sotelo J, Stuber M, Syed AB, Töger J, van der Geest R, Westenberg J, Zhong L, Zhong Y, Wieben O, Dyverfeldt P. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update. J Cardiovasc Magn Reson 2023; 25:40. [PMID: 37474977 PMCID: PMC10357639 DOI: 10.1186/s12968-023-00942-z] [Citation(s) in RCA: 42] [Impact Index Per Article: 42.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Accepted: 05/30/2023] [Indexed: 07/22/2023] Open
Abstract
Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.
Collapse
Affiliation(s)
- Malenka M Bissell
- Department of Biomedical Imaging Science, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), LIGHT Laboratories, Clarendon Way, University of Leeds, Leeds, LS2 9NL, UK.
| | | | - Lamia Ait Ali
- Institute of Clinical Physiology CNR, Massa, Italy
- Foundation CNR Tuscany Region G. Monasterio, Massa, Italy
| | - Bradley D Allen
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Alex J Barker
- Department of Radiology, Children's Hospital Colorado, University of Colorado Anschutz Medical Center, Aurora, USA
| | - Ann Bolger
- Department of Medicine, University of California, San Francisco, CA, USA
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Nicholas Burris
- Department of Radiology, University of Michigan, Ann Arbor, USA
| | - Carl-Johan Carhäll
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Tino Ebbers
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | | | - Alex Frydrychowicz
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
| | - Pankaj Garg
- Norwich Medical School, University of East Anglia, Norwich, UK
| | - Julia Geiger
- Department of Diagnostic Imaging, University Children's Hospital, Zurich, Switzerland
- Children's Research Center, University Children's Hospital Zurich, Zurich, Switzerland
| | - Hojin Ha
- Department of Mechanical and Biomedical Engineering, Kangwon National University, Chuncheon, South Korea
| | - Anja Hennemuth
- Institute of Computer-Assisted Cardiovascular Medicine, Charité - Universitätsmedizin, Berlin, Germany
- German Center for Cardiovascular Research (DZHK), Partner Site, Berlin, Germany
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael D Hope
- Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA, USA
| | - Albert Hsiao
- Department of Radiology, University of California, San Diego, CA, USA
| | - Kevin Johnson
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Sebastian Kozerke
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
| | - Liliana E Ma
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Michael Markl
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
| | - Duarte Martins
- Department of Pediatric Cardiology, Hospital de Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal
| | - Marci Messina
- Department of Radiology, Northwestern Medicine, Chicago, IL, USA
| | - Thekla H Oechtering
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck and Universität Zu Lübeck, Lübeck, Germany
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Pim van Ooij
- Department of Radiology & Nuclear Medicine, Amsterdam Cardiovascular Sciences, Amsterdam Movement Sciences, Amsterdam University Medical Centers, Location AMC, Amsterdam, The Netherlands
- Department of Pediatric Cardiology, Division of Pediatrics, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Cynthia Rigsby
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Imaging, Ann & Robert H Lurie Children's Hospital of Chicago, Chicago, IL, USA
| | - Jose Rodriguez-Palomares
- Department of Cardiology, Hospital Universitari Vall d´Hebron,Vall d'Hebron Institut de Recerca (VHIR), Universitat Autònoma de Barcelona, Barcelona, Spain
- Centro de Investigación Biomédica en Red-CV, CIBER CV, Madrid, Spain
| | - Arno A W Roest
- Department of Pediatric Cardiology, Willem-Alexander's Children Hospital, Leiden University Medical Center and Center for Congenital Heart Defects Amsterdam-Leiden, Leiden, The Netherlands
| | | | - Susanne Schnell
- Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, IL, USA
- Department of Medical Physics, Institute of Physics, University of Greifswald, Greifswald, Germany
| | - Julio Sotelo
- School of Biomedical Engineering, Universidad de Valparaíso, Valparaíso, Chile
- Biomedical Imaging Center, Pontificia Universidad Catolica de Chile, Santiago, Chile
- Millennium Institute for Intelligent Healthcare Engineering - iHEALTH, Santiago, Chile
| | - Matthias Stuber
- Département de Radiologie Médicale, Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland
| | - Ali B Syed
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Johannes Töger
- Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden
| | - Rob van der Geest
- Division of Image Processing, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jos Westenberg
- CardioVascular Imaging Group (CVIG), Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Liang Zhong
- National Heart Centre Singapore, Duke-NUS Medical School, National University of Singapore, Singapore, Singapore
| | - Yumin Zhong
- Department of Radiology, School of Medicine, Shanghai Children's Medical Center Affiliated With Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Oliver Wieben
- Departments of Radiology and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Petter Dyverfeldt
- Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
10
|
Varga-Szemes A, Maurovich-Horvat P, Schoepf UJ, Zsarnoczay E, Pelberg R, Stone GW, Budoff MJ. Computed Tomography Assessment of Coronary Atherosclerosis: From Threshold-Based Evaluation to Histologically Validated Plaque Quantification. J Thorac Imaging 2023; 38:226-234. [PMID: 37115957 PMCID: PMC10287054 DOI: 10.1097/rti.0000000000000711] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/30/2023]
Abstract
Arterial plaque rupture and thrombosis is the primary cause of major cardiovascular and neurovascular events. The identification of atherosclerosis, especially high-risk plaques, is therefore crucial to identify high-risk patients and to implement preventive therapies. Computed tomography angiography has the ability to visualize and characterize vascular plaques. The standard methods for plaque evaluation rely on the assessment of plaque burden, stenosis severity, the presence of positive remodeling, napkin ring sign, and spotty calcification, as well as Hounsfield Unit (HU)-based thresholding for plaque quantification; the latter with multiple shortcomings. Semiautomated threshold-based segmentation techniques with predefined HU ranges identify and quantify limited plaque characteristics, such as low attenuation, non-calcified, and calcified plaque components. Contrary to HU-based thresholds, histologically validated plaque characterization, and quantification, an emerging Artificial intelligence-based approach has the ability to differentiate specific tissue types based on a biological correlate, such as lipid-rich necrotic core and intraplaque hemorrhage that determine plaque vulnerability. In this article, we review the relevance of plaque characterization and quantification and discuss the benefits and limitations of the currently available plaque assessment and classification techniques.
Collapse
Affiliation(s)
- Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Pal Maurovich-Horvat
- MTA-SE Cardiovascular Imaging Research Group, Medical Imaging Centre, Semmelweis University, Budapest, Hungary
| | - U. Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
| | - Emese Zsarnoczay
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC
- MTA-SE Cardiovascular Imaging Research Group, Medical Imaging Centre, Semmelweis University, Budapest, Hungary
| | - Robert Pelberg
- Heart and Vascular Institute at The Christ Hospital Health Network, Cincinnati, OH
| | - Gregg W. Stone
- Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, NY
| | - Matthew J. Budoff
- Department of Medicine, Lundquist Institute at Harbor-UCLA Medical Center, Torrance, CA
| |
Collapse
|
11
|
Kilinc O, Chu S, Baraboo J, Weiss EK, Engel J, Maroun A, Giese D, Jin N, Chow K, Bi X, Davids R, Mehta C, Malaisrie SC, Hoel A, Carr J, Markl M, Allen BD. Hemodynamic Evaluation of Type B Aortic Dissection Using Compressed Sensing Accelerated 4D Flow MRI. J Magn Reson Imaging 2023; 57:1752-1763. [PMID: 36148924 PMCID: PMC10033465 DOI: 10.1002/jmri.28432] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/30/2022] [Accepted: 09/03/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND 4D Flow MRI is a quantitative imaging technique to evaluate blood flow patterns; however, it is unclear how compressed sensing (CS) acceleration would impact aortic hemodynamic quantification in type B aortic dissection (TBAD). PURPOSE To investigate CS-accelerated 4D Flow MRI performance compared to GRAPP-accelerated 4D Flow MRI (GRAPPA) to evaluate aortic hemodynamics in TBAD. STUDY TYPE Prospective. POPULATION Twelve TBAD patients, two volunteers. FIELD STRENGTH/SEQUENCE 1.5T, 3D time-resolved cine phase-contrast gradient echo sequence. ASSESSMENT GRAPPA (acceleration factor [R] = 2) and two CS-accelerated (R = 7.7 [CS7.7] and 10.2 [CS10.2]) 4D Flow MRI scans were acquired twice for interscan reproducibility assessment. Voxelwise kinetic energy (KE), peak velocity (PV), forward flow (FF), reverse flow (RF), and stasis were calculated. Plane-based mid-lumen flows were quantified. Imaging times were recorded. TESTS Repeated measures analysis of variance, Pearson correlation coefficients (r), intraclass correlation coefficients (ICC). P < 0.05 indicated statistical significance. RESULTS The KE and FF in true lumen (TL) and PV in false lumen (FL) did not show difference among three acquisition types (P = 0.818, 0.065, 0.284 respectively). The PV and stasis in TL were higher, KE, FF, and RF in FL were lower, and stasis was higher in GRAPPA compared to CS7.7 and CS10.2. The RF was lower in GRAPPA compared to CS10.2. The correlation coefficients were strong in TL (r = [0.781-0.986]), and low to strong in FL (r = [0.347-0.948]). The ICC levels demonstrated moderate to excellent interscan reproducibility (0.732-0.989). The FF and net flow in mid-descending aorta TL were significantly different between CS7.7 and CS10.2. CONCLUSION CS-accelerated 4D Flow MRI has potential for clinical utilization with shorter scan times in TBAD. Our results suggest similar hemodynamic trends between acceleration types, but CS-acceleration impacts KE, FF, RF, and stasis more in FL. EVIDENCE LEVEL 1 Technical Efficacy: Stage 2.
Collapse
Affiliation(s)
- Ozden Kilinc
- Department of Radiology, Northwestern University, Chicago, Illinois
| | - Stanley Chu
- Department of Radiology, Northwestern University, Chicago, Illinois
| | - Justin Baraboo
- Department of Radiology, Northwestern University, Chicago, Illinois
- Department of Biomedical Engineering, Northwestern University, Chicago, Illinois
| | - Elizabeth K. Weiss
- Department of Radiology, Northwestern University, Chicago, Illinois
- Department of Biomedical Engineering, Northwestern University, Chicago, Illinois
| | - Joshua Engel
- Department of Radiology, Northwestern University, Chicago, Illinois
| | - Anthony Maroun
- Department of Radiology, Northwestern University, Chicago, Illinois
| | - Daniel Giese
- Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Germany
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Ning Jin
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Cleveland, Ohio
| | - Kelvin Chow
- Department of Radiology, Northwestern University, Chicago, Illinois
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, Illinois
| | - Xiaoming Bi
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, Illinois
| | - Rachel Davids
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, Illinois
| | - Christopher Mehta
- Department of Surgery (Cardiac Surgery), Northwestern University, Chicago, Illinois
| | | | - Andrew Hoel
- Department of Surgery (Vascular Surgery), Northwestern University, Chicago, Illinois
| | - James Carr
- Department of Radiology, Northwestern University, Chicago, Illinois
| | - Michael Markl
- Department of Radiology, Northwestern University, Chicago, Illinois
- Department of Biomedical Engineering, Northwestern University, Chicago, Illinois
| | - Bradley D. Allen
- Department of Radiology, Northwestern University, Chicago, Illinois
| |
Collapse
|
12
|
Estimation of venous sinus pressure drop in patients with idiopathic intracranial hypertension using 4D-flow MRI. Eur Radiol 2023; 33:2576-2584. [PMID: 36287270 DOI: 10.1007/s00330-022-09199-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Revised: 07/28/2022] [Accepted: 09/23/2022] [Indexed: 01/25/2023]
Abstract
OBJECTIVE We aimed to explore a non-invasive estimate of pressure drop in patients who undergo venous sinus stenting to treat idiopathic intracranial hypertension (IIH). METHODS This prospective study included 28 IIH patients scheduled for venous stenting. 4D-flow MRI was acquired 24-48 h before venous manometry. Manometry-obtained pressure drop (Mp) was dichotomized into low (Lp: 0-8 mmHg) and high (Hp: 8-30 mmHg) groups. Hemodynamic indices were compared between Lp and Hp. Trans-stenotic pressure drop was estimated by work-energy equation, simplified Bernoulli equation, vorticity magnitude, and velocity difference between inlet and outlet and was compared with Mp. Measurement agreement, correlation, and accuracy were evaluated using the κ coefficient, Pearson's r, and confusion matrix-derived accuracy. RESULTS Among 28 patients (mean age 38.8 ± 12.7), 19 (67.9%) were female. Work-energy equation-estimated pressure drop (WEp) had strong correlation (r = 0.91, 95% confidence interval [CI]: 0.81-0.96, p < 0.001) and high agreement (intraclass correlation coefficient = 0.90, 95% CI: 0.78-0.95, p < 0.001) with Mp. WEp classified Lp and Hp with an accuracy of 0.96. The κ value between WEp and Mp was 0.92 (95% CI: 0.78-1.00). In the work-energy equation, the viscosity energy term (Ve) had the largest weights, and the ratio of Ve to the summation of the three energy terms was 0.93 ± 0.07. Ve had strong correlation with mVort (r = 0.93, 95% CI: 0.85-0.97, p < 0.001), and mean vorticity magnitude was significantly elevated in Hp compared to that in Lp (259.8 vs. 174.9 mL/s, p < 0.001). CONCLUSION Trans-stenotic pressure drop in IIH can be estimated using the work-energy equation with favorable accuracy. KEY POINTS • Trans-stenotic pressure drop in patients with idiopathic intracranial hypertension can be estimated accurately with the work-energy equation using the 4D-flow MRI full velocity field. • Compared with traditional venous sinus manometry, the 4D-flow MRI-derived pressure drop is totally non-invasive and cost-saving. • 4D-flow MRI may help neurointerventionalist to select IIH patients suitable for venous sinus stenting.
Collapse
|
13
|
Battal B, Zamora C. Editorial Comment: Estimation of venous sinus pressure drop in patients with idiopathic intracranial hypertension using 4D-flow MRI. Eur Radiol 2023; 33:2574-2575. [PMID: 36692599 DOI: 10.1007/s00330-023-09395-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 10/19/2022] [Accepted: 11/21/2022] [Indexed: 01/25/2023]
Abstract
KEY POINTS • Work-energy equation using 4D-flow MRI is a promising technique for non-invasive estimation of trans-stenotic pressure drop in patients with idiopathic intracranial hypertension.• Additional research with larger and multicentric prospective cohorts is needed to validate the results, along with improvement of the segmentation process with automated techniques and shortening of scanning times to allow for practical clinical use.
Collapse
Affiliation(s)
- Bilal Battal
- Division of Neuroradiology, Department of Radiology, University of North Carolina School of Medicine, 101 Manning Dr, CB 7510, 2000 Old Clinic, Chapel Hill, NC, 27599, USA.
| | - Carlos Zamora
- Division of Neuroradiology, Department of Radiology, University of North Carolina School of Medicine, 101 Manning Dr, CB 7510, 2000 Old Clinic, Chapel Hill, NC, 27599, USA
| |
Collapse
|
14
|
Update on the roles of imaging in the management of chronic thromboembolic pulmonary hypertension. J Cardiol 2023; 81:297-306. [PMID: 35490106 DOI: 10.1016/j.jjcc.2022.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 03/02/2022] [Indexed: 02/01/2023]
Abstract
Chronic thromboembolic pulmonary hypertension (CTEPH), classified as group 4 pulmonary hypertension (PH), is caused by stenosis and obstruction of the pulmonary arteries by organized thrombi that are incompletely resolved after acute pulmonary embolism. The prognosis of patients with CTEPH is poor if untreated; however, in expert centers with multidisciplinary teams, a treatment strategy for CTEPH has been established, dramatically improving its prognosis. CTEPH is currently not a fatal disease and is the only curable form of PH. Despite these advances and the establishment of treatment approaches, early diagnosis is still challenging, especially for non-experts, for several reasons. One of the reasons for this is insufficient knowledge of the various diagnostic imaging modalities, which are essential in the clinical practice of CTEPH. Imaging modalities should detect the following pathological findings: lung perfusion defects, thromboembolic lesions in pulmonary arteries, and right ventricular remodeling and dysfunction. Perfusion lung scintigraphy and catheter angiography have long been considered gold standards for the detection of perfusion defects and assessment of vascular lesions, respectively. However, advances in imaging technology of computed tomography and magnetic resonance imaging have enabled the non-invasive detection of these abnormal findings in a single examination. Cardiac magnetic resonance (CMR) is the gold standard for evaluating the morphology and function of the right heart; however, state-of-the-art techniques in CMR allow the assessment of cardiac tissue characterization and hemodynamics in the pulmonary arteries. Comprehensive knowledge of the role of imaging in CTEPH enables appropriate use of imaging modalities and accurate image interpretation, resulting in early diagnosis, determination of treatment strategies, and appropriate evaluation of treatment efficacy. This review summarizes the current roles of imaging in the clinical practice for CTEPH, demonstrating the characteristic findings observed in each modality.
Collapse
|
15
|
Hurd ER, Han M, Mendes JK, Hadley JR, Johnson CR, DiBella EVR, Oshinski JN, Timmins LH. Comparison of Prospective and Retrospective Gated 4D Flow Cardiac MR Image Acquisitions in the Carotid Bifurcation. Cardiovasc Eng Technol 2023; 14:1-12. [PMID: 35618870 DOI: 10.1007/s13239-022-00630-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 05/06/2022] [Indexed: 11/02/2022]
Abstract
PURPOSE To evaluate the agreement of 4D flow cMRI-derived bulk flow features and fluid (blood) velocities in the carotid bifurcation using prospective and retrospective gating techniques. METHODS Prospective and retrospective ECG-gated three-dimensional (3D) cine phase-contrast cardiac MRI with three-direction velocity encoding (i.e., 4D flow cMRI) data were acquired in ten carotid bifurcations from men (n = 3) and women (n = 2) that were cardiovascular disease-free. MRI sequence parameters were held constant across all scans except temporal resolution values differed. Velocity data were extracted from the fluid domain and evaluated across the entire volume or at defined anatomic planes (common, internal, external carotid arteries). Qualitative agreement between gating techniques was performed by visualizing flow streamlines and topographical images, and statistical comparisons between gating techniques were performed across the fluid volume and defined anatomic regions. RESULTS Agreement in the kinematic data (e.g., bulk flow features and velocity data) were observed in the prospectively and retrospectively gated acquisitions. Voxel differences in time-averaged, peak systolic, and diastolic-averaged velocity magnitudes between gating techniques across all volunteers were 2.7%, 1.2%, and 6.4%, respectively. No significant differences in velocity magnitudes or components ([Formula: see text], [Formula: see text], [Formula: see text]) were observed. Importantly, retrospective acquisitions captured increased retrograde flow in the internal carotid artery (i.e., carotid sinus) compared to prospective acquisitions (10.4 ± 6.3% vs. 4.6 ± 5.3%; [Formula: see text] < 0.05). CONCLUSION Prospective and retrospective ECG-gated 4D flow cMRI acquisitions provide comparable evaluations of fluid velocities, including velocity vector components, in the carotid bifurcation. However, the increased temporal coverage of retrospective acquisitions depicts increased retrograde flow patterns (i.e., disturbed flow) not captured by the prospective gating technique.
Collapse
Affiliation(s)
- Elliott R Hurd
- Department of Biomedical Engineering, University of Utah, 36 S. Wasatch Drive, Rm. 3100, Salt Lake City, UT, 84112, USA
| | - Mengjiao Han
- School of Computing, University of Utah, Salt Lake City, UT, 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah, 84112, USA
| | - Jason K Mendes
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, 84112, USA
| | - J Rock Hadley
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, 84112, USA
| | - Chris R Johnson
- Department of Biomedical Engineering, University of Utah, 36 S. Wasatch Drive, Rm. 3100, Salt Lake City, UT, 84112, USA
- School of Computing, University of Utah, Salt Lake City, UT, 84112, USA
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah, 84112, USA
| | - Edward V R DiBella
- Department of Biomedical Engineering, University of Utah, 36 S. Wasatch Drive, Rm. 3100, Salt Lake City, UT, 84112, USA
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, 84112, USA
| | - John N Oshinski
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, 30322, USA
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA, 30332, USA
| | - Lucas H Timmins
- Department of Biomedical Engineering, University of Utah, 36 S. Wasatch Drive, Rm. 3100, Salt Lake City, UT, 84112, USA.
- Scientific Computing and Imaging Institute, University of Utah, Salt Lake City, Utah, 84112, USA.
| |
Collapse
|
16
|
Roos PR, Rijnberg FM, Westenberg JJM, Lamb HJ. Particle Tracing Based on
4D
Flow Magnetic Resonance Imaging: A Systematic Review into Methods, Applications, and Current Developments. J Magn Reson Imaging 2022; 57:1320-1339. [PMID: 36484213 DOI: 10.1002/jmri.28540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 11/15/2022] [Accepted: 11/15/2022] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Particle tracing based on 4D Flow MRI has been applied as a quantitative and qualitative postprocessing technique to study temporally evolving blood flow patterns. PURPOSE To systematically review the various methods to perform 4D Flow MRI-based particle tracing, as well as the clinical value, clinical applications, and current developments of the technique. STUDY TYPE The study type is systematic review. SUBJECTS Patients with cardiovascular disease (such as Marfan, Fontan, Tetralogy of Fallot), healthy controls, and cardiovascular phantoms that received 4D Flow MRI with particle tracing. FIELD STRENGTH/SEQUENCE Three-dimensional three-directional cine phase-contrast MRI, at 1.5 T and 3 T. ASSESSMENT Two systematic searches were performed on the PubMed database using Boolean operators and the relevant key terms covering 4D Flow MRI and particle tracing. One systematic search was focused on particle tracing methods, whereas the other on applications. Additional articles from other sources were sought out and included after a similar inspection. Particle tracing methods, clinical applications, clinical value, and current developments were extracted. STATISTICAL TESTS The main results of the included studies are summarized, without additional statistical analysis. RESULTS Of 127 unique articles retrieved from the initial search, 56 were included (28 for methods and 54 for applications). Most articles that described particle tracing methods used an adaptive timestep, a fourth order Runge-Kutta integration method, and linear interpolation in the time dimension. Particle tracing was applied in heart chambers, aorta, venae cavae, Fontan circulation, pulmonary arteries, abdominal vasculature, peripheral arteries, carotid arteries, and cerebral vasculature. Applications were grouped as intravascular, intracardiac, flow stasis, and research. DATA CONCLUSIONS Particle tracing based on 4D Flow MRI gives unique insight into blood flow in several cardiovascular diseases, but the quality depends heavily on the MRI data quality. Further studies are required to evaluate the clinical value of the technique for different cardiovascular diseases. EVIDENCE LEVEL 5. TECHNICAL EFFICACY Stage 1.
Collapse
Affiliation(s)
- Paul R. Roos
- Department of Radiology Leiden University Medical Center Leiden The Netherlands
| | - Friso M. Rijnberg
- Department of Cardiothoracic Surgery Leiden University Medical Center Leiden The Netherlands
| | | | - Hildo J. Lamb
- Department of Radiology Leiden University Medical Center Leiden The Netherlands
| |
Collapse
|
17
|
Nath R, Callahan S, Stoddard M, Amini AA. FlowRAU-Net: Accelerated 4D Flow MRI of Aortic Valvular Flows With a Deep 2D Residual Attention Network. IEEE Trans Biomed Eng 2022; 69:3812-3824. [PMID: 35675233 PMCID: PMC10577002 DOI: 10.1109/tbme.2022.3180691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In this work, we propose a novel deep learning reconstruction framework for rapid and accurate reconstruction of 4D flow MRI data. Reconstruction is performed on a slice-by-slice basis by reducing artifacts in zero-filled reconstructed complex images obtained from undersampled k-space. A deep residual attention network FlowRAU-Net is proposed, trained separately for each encoding direction with 2D complex image slices extracted from complex 4D images at each temporal frame and slice position. The network was trained and tested on 4D flow MRI data of aortic valvular flow in 18 human subjects. Performance of the reconstructions was measured in terms of image quality, 3-D velocity vector accuracy, and accuracy in hemodynamic parameters. Reconstruction performance was measured for three different k-space undersamplings and compared with one state of the art compressed sensing reconstruction method and three deep learning-based reconstruction methods. The proposed method outperforms state of the art methods in all performance measures for all three different k-space undersamplings. Hemodynamic parameters such as blood flow rate and peak velocity from the proposed technique show good agreement with reference flow parameters. Visualization of the reconstructed image and velocity magnitude also shows excellent agreement with the fully sampled reference dataset. Moreover, the proposed method is computationally fast. Total 4D flow data (including all slices in space and time) for a subject can be reconstructed in 69 seconds on a single GPU. Although the proposed method has been applied to 4D flow MRI of aortic valvular flows, given a sufficient number of training samples, it should be applicable to other arterial flows.
Collapse
|
18
|
Richards CE, Parker AE, Alfuhied A, McCann GP, Singh A. The role of 4-dimensional flow in the assessment of bicuspid aortic valve and its valvulo-aortopathies. Br J Radiol 2022; 95:20220123. [PMID: 35852109 PMCID: PMC9793489 DOI: 10.1259/bjr.20220123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Bicuspid aortic valve is the most common congenital cardiac malformation and the leading cause of aortopathy and aortic stenosis in younger patients. Aortic wall remodelling secondary to altered haemodynamic flow patterns, changes in peak velocity, and wall shear stress may be implicated in the development of aortopathy in the presence of bicuspid aortic valve and dysfunction. Assessment of these parameters as potential predictors of disease severity and progression is thus desirable. The anatomic and functional information acquired from 4D flow MRI can allow simultaneous visualisation and quantification of the pathological geometric and haemodynamic changes of the aorta. We review the current clinical utility of haemodynamic quantities including velocity, wall sheer stress and energy losses, as well as visual descriptors such as vorticity and helicity, and flow direction in assessing the aortic valve and associated aortopathies.
Collapse
Affiliation(s)
- Caryl Elizabeth Richards
- Department of Cardiovascular Sciences, University of Leicester and the National Institute for Health Research Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - Alex E Parker
- Leicester Medical School, University of Leicester, Leicester, UK
| | - Aseel Alfuhied
- Department of Cardiovascular Sciences, University of Leicester and the National Institute for Health Research Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - Gerry P McCann
- Department of Cardiovascular Sciences, University of Leicester and the National Institute for Health Research Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| | - Anvesha Singh
- Department of Cardiovascular Sciences, University of Leicester and the National Institute for Health Research Leicester Biomedical Research Centre, Glenfield Hospital, Leicester, UK
| |
Collapse
|
19
|
Varga-Szemes A, Halfmann M, Schoepf UJ, Jin N, Kilburg A, Dargis DM, Düber C, Ese A, Aquino G, Xiong F, Kreitner KF, Markl M, Emrich T. Highly Accelerated Compressed-Sensing 4D Flow for Intracardiac Flow Assessment. J Magn Reson Imaging 2022. [PMID: 36264176 DOI: 10.1002/jmri.28484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 10/03/2022] [Accepted: 10/04/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Four-dimensional (4D) flow MRI allows for the quantification of complex flow patterns; however, its clinical use is limited by its inherently long acquisition time. Compressed sensing (CS) is an acceleration technique that provides substantial reduction in acquisition time. PURPOSE To compare intracardiac flow measurements between conventional and CS-based highly accelerated 4D flow acquisitions. STUDY TYPE Prospective. SUBJECTS Fifty healthy volunteers (28.0 ± 7.1 years, 24 males). FIELD STRENGTH/SEQUENCE Whole heart time-resolved 3D gradient echo with three-directional velocity encoding (4D flow) with conventional parallel imaging (factor 3) as well as CS (factor 7.7) acceleration at 3 T. ASSESSMENT 4D flow MRI data were postprocessed by applying a valve tracking algorithm. Acquisition times, flow volumes (mL/cycle) and diastolic function parameters (ratio of early to late diastolic left ventricular peak velocities [E/A] and ratio of early mitral inflow velocity to mitral annular early diastolic velocity [E/e']) were quantified by two readers. STATISTICAL TESTS Paired-samples t-test and Wilcoxon rank sum test to compare measurements. Pearson correlation coefficient (r), Bland-Altman-analysis (BA) and intraclass correlation coefficient (ICC) to evaluate agreement between techniques and readers. A P value < 0.05 was considered statistically significant. RESULTS A significant improvement in acquisition time was observed using CS vs. conventional accelerated acquisition (6.7 ± 1.3 vs. 12.0 ± 1.3 min). Net forward flow measurements for all valves showed good correlation (r > 0.81) and agreement (ICCs > 0.89) between conventional and CS acceleration, with 3.3%-8.3% underestimation by the CS technique. Evaluation of diastolic function showed 3.2%-17.6% error: E/A 2.2 [1.9-2.4] (conventional) vs. 2.3 [2.0-2.6] (CS), BA bias 0.08 [-0.81-0.96], ICC 0.82; and E/e' 4.6 [3.9-5.4] (conventional) vs. 3.8 [3.4-4.3] (CS), BA bias -0.90 [-2.31-0.50], ICC 0.89. DATA CONCLUSION Analysis of intracardiac flow patterns and evaluation of diastolic function using a highly accelerated 4D flow sequence prototype is feasible, but it shows underestimation of flow measurements by approximately 10%. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Akos Varga-Szemes
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Moritz Halfmann
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany.,German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
| | - U Joseph Schoepf
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Ning Jin
- Siemens Medical Solutions USA Inc., Chicago, Illinois, USA
| | - Anton Kilburg
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Danielle M Dargis
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Christoph Düber
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Amir Ese
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Gilberto Aquino
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina
| | - Fei Xiong
- Siemens Medical Solutions USA Inc., Chicago, Illinois, USA
| | - Karl-Friedrich Kreitner
- Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Michael Markl
- Department of Radiology, Northwestern University, Feinberg School of Medicine, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA
| | - Tilman Emrich
- Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, South Carolina.,Department of Diagnostic and Interventional Radiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany.,German Centre for Cardiovascular Research, Partner site Rhine-Main, Mainz, Germany
| |
Collapse
|
20
|
Oechtering TH, Roberts GS, Panagiotopoulos N, Wieben O, Roldán-Alzate A, Reeder SB. Abdominal applications of quantitative 4D flow MRI. Abdom Radiol (NY) 2022; 47:3229-3250. [PMID: 34837521 PMCID: PMC9135957 DOI: 10.1007/s00261-021-03352-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 11/11/2021] [Accepted: 11/12/2021] [Indexed: 01/18/2023]
Abstract
4D flow MRI is a quantitative MRI technique that allows the comprehensive assessment of time-resolved hemodynamics and vascular anatomy over a 3-dimensional imaging volume. It effectively combines several advantages of invasive and non-invasive imaging modalities like ultrasound, angiography, and computed tomography in a single MRI acquisition and provides an unprecedented characterization of velocity fields acquired non-invasively in vivo. Functional and morphological imaging of the abdominal vasculature is especially challenging due to its complex and variable anatomy with a wide range of vessel calibers and flow velocities and the need for large volumetric coverage. Despite these challenges, 4D flow MRI is a promising diagnostic and prognostic tool as many pathologies in the abdomen are associated with changes of either hemodynamics or morphology of arteries, veins, or the portal venous system. In this review article, we will discuss technical aspects of the implementation of abdominal 4D flow MRI ranging from patient preparation and acquisition protocol over post-processing and quality control to final data analysis. In recent years, the range of applications for 4D flow in the abdomen has increased profoundly. Therefore, we will review potential clinical applications and address their clinical importance, relevant quantitative and qualitative parameters, and unmet challenges.
Collapse
Affiliation(s)
- Thekla H. Oechtering
- University of Wisconsin, Department of Radiology, Madison, WI, United States,Universität zu Lübeck, Department of Radiology, Luebeck, Germany
| | - Grant S. Roberts
- University of Wisconsin, Department of Medical Physics, Madison, WI, United States
| | - Nikolaos Panagiotopoulos
- University of Wisconsin, Department of Radiology, Madison, WI, United States,Universität zu Lübeck, Department of Radiology, Luebeck, Germany
| | - Oliver Wieben
- University of Wisconsin, Department of Radiology, Madison, WI, United States,University of Wisconsin, Department of Medical Physics, Madison, WI, United States
| | - Alejandro Roldán-Alzate
- University of Wisconsin, Department of Radiology, Madison, WI, United States,University of Wisconsin, Department of Mechanical Engineering, Madison, WI, United States,University of Wisconsin, Department of Biomedical Engineering, Madison, WI, United States
| | - Scott B. Reeder
- University of Wisconsin, Department of Radiology, Madison, WI, United States,University of Wisconsin, Department of Medical Physics, Madison, WI, United States,University of Wisconsin, Department of Mechanical Engineering, Madison, WI, United States,University of Wisconsin, Department of Biomedical Engineering, Madison, WI, United States,University of Wisconsin, Department of Emergency Medicine, Madison, WI, United States
| |
Collapse
|
21
|
Nolte D, Bertoglio C. Inverse problems in blood flow modeling: A review. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2022; 38:e3613. [PMID: 35526113 PMCID: PMC9541505 DOI: 10.1002/cnm.3613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2021] [Revised: 12/29/2021] [Accepted: 03/18/2022] [Indexed: 06/14/2023]
Abstract
Mathematical and computational modeling of the cardiovascular system is increasingly providing non-invasive alternatives to traditional invasive clinical procedures. Moreover, it has the potential for generating additional diagnostic markers. In blood flow computations, the personalization of spatially distributed (i.e., 3D) models is a key step which relies on the formulation and numerical solution of inverse problems using clinical data, typically medical images for measuring both anatomy and function of the vasculature. In the last years, the development and application of inverse methods has rapidly expanded most likely due to the increased availability of data in clinical centers and the growing interest of modelers and clinicians in collaborating. Therefore, this work aims to provide a wide and comparative overview of literature within the last decade. We review the current state of the art of inverse problems in blood flows, focusing on studies considering fully dimensional fluid and fluid-solid models. The relevant physical models and hemodynamic measurement techniques are introduced, followed by a survey of mathematical data assimilation approaches used to solve different kinds of inverse problems, namely state and parameter estimation. An exhaustive discussion of the literature of the last decade is presented, structured by types of problems, models and available data.
Collapse
Affiliation(s)
- David Nolte
- Bernoulli InstituteUniversity of GroningenGroningenThe Netherlands
- Center for Mathematical ModelingUniversidad de ChileSantiagoChile
- Department of Fluid DynamicsTechnische Universität BerlinBerlinGermany
| | | |
Collapse
|
22
|
Njoku P, Wardley J, Garg P. Streamline-based three-dimensional peak-velocity tracing of transvalvular flow using four-dimensional flow cardiac magnetic resonance imaging for left ventricular diastolic assessment in aortic regurgitation: a case report. J Med Case Rep 2022; 16:205. [PMID: 35570306 PMCID: PMC9109406 DOI: 10.1186/s13256-022-03422-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Accepted: 04/24/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Doppler transthoracic echocardiography is routinely performed to measure peak mitral inflow velocities in the assessment of left ventricular diastolic function. The limitations of echocardiography are well documented, but its accuracy in the measurement of transmitral peak velocity in the presence of aortic valve regurgitation has not yet been compared with four-dimensional flow cardiac magnetic resonance imaging. Four-dimensional flow cardiac magnetic resonance imaging offers time-resolved cross-sectional velocity information that can be used to investigate mitral inflow peak velocity. We present a case report demonstrating the potential superior capabilities of four-dimensional flow cardiac magnetic resonance imaging in accurately detecting mitral inflow velocities over Doppler echocardiography in patients with aortic regurgitation. CASE PRESENTATION A 67-year-old Caucasian female presented to our outpatient cardiology clinic with exertional dyspnea. Doppler transthoracic echocardiography identified moderate to severe aortic regurgitation. Mapping of mitral inflow peak velocities proved challenging with Doppler echocardiography. Additionally, four-dimensional flow cardiac magnetic resonance imaging with automated three-dimensional flow streamlines was performed, which allowed for more accurate detection of mitral inflow peak velocities. CONCLUSIONS Doppler echocardiography has a limited role in mitral inflow assessment where aortic regurgitation is present. In such cases, four-dimensional flow cardiac magnetic resonance imaging is an alternative imaging technique that may circumvent this issue and allow mitral inflow assessment.
Collapse
Affiliation(s)
- Paul Njoku
- Cardiology, Norfolk and Norwich University Hospital NHS Trust, Norwich, UK
- Norwich Medical School, University of East Anglia, Norwich, NR4 7TJ, UK
| | - James Wardley
- Cardiology, Norfolk and Norwich University Hospital NHS Trust, Norwich, UK
- Norwich Medical School, University of East Anglia, Norwich, NR4 7TJ, UK
| | - Pankaj Garg
- Cardiology, Norfolk and Norwich University Hospital NHS Trust, Norwich, UK.
- Norwich Medical School, University of East Anglia, Norwich, NR4 7TJ, UK.
| |
Collapse
|
23
|
Isoda H, Fukuyama A. Quality Control for 4D Flow MR Imaging. Magn Reson Med Sci 2022; 21:278-292. [PMID: 35197395 PMCID: PMC9680545 DOI: 10.2463/mrms.rev.2021-0165] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Accepted: 01/08/2022] [Indexed: 01/06/2023] Open
Abstract
In recent years, 4D flow MRI has become increasingly important in clinical applications for the blood vessels in the whole body, heart, and cerebrospinal fluid. 4D flow MRI has advantages over 2D cine phase-contrast (PC) MRI in that any targeted area of interest can be analyzed post-hoc, but there are some factors to be considered, such as ensuring measurement accuracy, a long imaging time and post-processing complexity, and interobserver variability.Due to the partial volume phenomenon caused by low spatial and temporal resolutions, the accuracy of flow measurement in 4D flow MRI is reduced. For spatial resolution, it is recommended to include at least four voxels in the vessel of interest, and if possible, six voxels. In large vessels such as the aorta, large voxels can be secured and SNR can be maintained, but in small cerebral vessels, SNR is reduced, resulting in reduced accuracy. A temporal resolution of less than 40 ms is recommended. The velocity-to-noise ratio (VNR) of low-velocity blood flow is low, resulting in poor measurement accuracy. The use of dual velocity encoding (VENC) or multi-VENC is recommended to avoid velocity wrap around and to increase VNR. In order to maintain sufficient spatio-temporal resolution, a longer imaging time is required, leading to potential patient movement during examination and a corresponding decrease in measurement accuracy.For the clinical application of new technologies, including various acceleration techniques, in vitro and in vivo accuracy verification based on existing accuracy-validated 2D cine PC MRI and 4D flow MRI, as well as accuracy verification on the conservation of mass' principle, should be performed, and intraobserver repeatability, interobserver reproducibility, and test-retest reproducibility should be checked.
Collapse
Affiliation(s)
- Haruo Isoda
- Brain and Mind Research Center, Nagoya University, Nagoya, Aichi, Japan
- Biomedical Imaging Sciences, Department of Integrated Health Sciences, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Atsushi Fukuyama
- Faculty of Health Sciences, Department of Radiological Sciences, Japan Healthcare University, Sapporo, Hokkaido, Japan
| |
Collapse
|
24
|
Pravdivtseva MS, Gaidzik F, Berg P, Ulloa P, Larsen N, Jansen O, Hövener JB, Salehi Ravesh M. Influence of Spatial Resolution and Compressed SENSE Acceleration Factor on Flow Quantification with 4D Flow MRI at 3 Tesla. Tomography 2022; 8:457-478. [PMID: 35202203 PMCID: PMC8880336 DOI: 10.3390/tomography8010038] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 01/30/2022] [Accepted: 01/31/2022] [Indexed: 11/25/2022] Open
Abstract
Four-dimensional (4D) flow MRI allows quantifying flow in blood vessels–non invasively and in vivo. The clinical use of 4D flow MRI in small vessels, however, is hampered by long examination times and limited spatial resolution. Compressed SENSE (CS-SENSE) is a technique that can accelerate 4D flow dramatically. Here, we investigated the effect of spatial resolution and CS acceleration on flow measurements by using 4D flow MRI in small vessels in vitro at 3 T. We compared the flow in silicon tubes (inner diameters of 2, 3, 4, and 5 mm) measured with 4D flow MRI, accelerated with four CS factors (CS = 2.5, 4.5, 6.5, and 13) and three voxel sizes (0.5, 1, and 1.5 mm3) to 2D flow MRI and a flow sensor. Additionally, the velocity field in an aneurysm model acquired with 4D flow MRI was compared to the one simulated with computational fluid dynamics (CFD). A strong correlation was observed between flow sensor, 2D flow MRI, and 4D flow MRI (rho > 0.94). The use of fewer than seven voxels per vessel diameter (nROI) resulted in an overestimation of flow in more than 5% of flow measured with 2D flow MRI. A negative correlation (rho = −0.81) between flow error and nROI were found for CS = 2.5 and 4.5. No statistically significant impact of CS factor on differences in flow rates was observed. However, a trend of increased flow error with increased CS factor was observed. In an aneurysm model, the peak velocity and stagnation zone were detected by CFD and all 4D flow MRI variants. The velocity difference error in the aneurysm sac did not exceed 11% for CS = 4.5 in comparison to CS = 2.5 for all spatial resolutions. Therefore, CS factors from 2.5–4.5 can appear suitable to improve spatial or temporal resolution for accurate quantification of flow rate and velocity. We encourage reporting the number of voxels per vessel diameter to standardize 4D flow MRI protocols.
Collapse
Affiliation(s)
- Mariya S. Pravdivtseva
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
- Correspondence: ; Tel.: +49-(0)-431-500-16-533
| | - Franziska Gaidzik
- Department of Fluid Dynamics and Technical Flows, Research Campus STIMULATE, Magdeburg University, 39106 Magdeburg, Germany; (F.G.); (P.B.)
| | - Philipp Berg
- Department of Fluid Dynamics and Technical Flows, Research Campus STIMULATE, Magdeburg University, 39106 Magdeburg, Germany; (F.G.); (P.B.)
| | - Patricia Ulloa
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
| | - Naomi Larsen
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, 24105 Kiel, Germany; (N.L.); (O.J.)
| | - Olav Jansen
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel University, 24105 Kiel, Germany; (N.L.); (O.J.)
| | - Jan-Bernd Hövener
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
| | - Mona Salehi Ravesh
- Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Kiel University, 24105 Kiel, Germany; (P.U.); (J.-B.H.); (M.S.R.)
| |
Collapse
|
25
|
Hyodo R, Takehara Y, Mizuno T, Ichikawa K, Yokoyama S, Ishizu Y, Naganawa S. Assessing the Complicated Venous Hemodynamics and Therapeutic Outcomes of Budd-Chiari Syndrome with Respiratory-gated 4D Flow MR Imaging During the Expiratory and Inspiratory Phases. Magn Reson Med Sci 2021; 22:1-6. [PMID: 34880192 PMCID: PMC9849410 DOI: 10.2463/mrms.ici.2021-0110] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
A man in his 50s with Budd-Chiari syndrome diagnosed with the suprahepatic inferior vena cava (IVC) obstruction on CT was assessed using 4D Flow MRI before and after balloon angioplasty. 4D Flow MRI acquired in two respiratory phases, depicted complex hemodynamic and respiratory variability, and a jet stream at the narrowed channel of the membranous IVC. Post-interventional 4D Flow MRI showed that the IVC blood flow increased with corrected flow directions in the infrarenal IVC.
Collapse
Affiliation(s)
- Ryota Hyodo
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan,Corresponding author: Department of Radiology, Nagoya University Graduate School of Medicine, 65, Tsurumai-cho, Showa-ku, Nagoya, Aichi 466-8550, Japan. Phone: +81-52-744-2327, Fax: +81-52-744-2335, E-mail:
| | - Yasuo Takehara
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan,Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Takashi Mizuno
- Department of Medical Technology, Nagoya University Hospital, Nagoya, Aichi, Japan
| | - Kazushige Ichikawa
- Department of Medical Technology, Nagoya University Hospital, Nagoya, Aichi, Japan
| | - Shinya Yokoyama
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Yoji Ishizu
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| | - Shinji Naganawa
- Department of Radiology, Nagoya University Graduate School of Medicine, Nagoya, Aichi, Japan
| |
Collapse
|
26
|
Oyama-Manabe N, Aikawa T, Tsuneta S, Manabe O. Clinical Applications of 4D Flow MR Imaging in Aortic Valvular and Congenital Heart Disease. Magn Reson Med Sci 2021; 21:319-326. [PMID: 34176866 DOI: 10.2463/mrms.rev.2021-0030] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
4D flow MRI allows time-resolved 3D velocity-encoded phase-contrast imaging for 3D visualization and quantification of aortic and intracardiac flow. Radiologists should be familiar with the principles of 4D flow MRI and methods for evaluating blood flow qualitatively and quantitatively. The most substantial benefits of 4D flow MRI are that it enables the simultaneous comprehensive assessment of different vessels, and that retrospective analysis can be achieved in all vessels in any direction in the field of view, which is especially beneficial for patients with complicated congenital heart disease (CHD). For aortic valvular diseases, new parameters such as wall shear stress and energy loss may provide new prognostic values for 4D flow MRI. In this review, we introduce the clinical applications of 4D flow MRI for the visualization of blood flow and quantification of hemodynamic metrics in the setting of aortic valvular disease and CHD, including intracardiac shunt and coronary artery anomaly.
Collapse
Affiliation(s)
| | - Tadao Aikawa
- Department of Radiology, Jichi Medical University Saitama Medical Center
| | - Satonori Tsuneta
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital
| | - Osamu Manabe
- Department of Radiology, Jichi Medical University Saitama Medical Center
| |
Collapse
|
27
|
Hyodo R, Takehara Y, Mizuno T, Ichikawa K, Ishizu Y, Sugiyama M, Naganawa S. Time-resolved 3D cine phase-contrast magnetic resonance imaging (4D-flow MRI) can quantitatively assess portosystemic shunt severity and confirm normalization of portal flow after embolization of large portosystemic shunts. Hepatol Res 2021; 51:343-349. [PMID: 33434371 DOI: 10.1111/hepr.13616] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 12/20/2020] [Accepted: 12/27/2020] [Indexed: 12/13/2022]
Abstract
Diagnosis and severity assessments of portosystemic shunts (PSSs) are important because the pathology sometimes results in severe hepatic encephalopathy, which can be treated almost completely by shunt embolization. At present, morphological assessment of PSS is performed mainly by computed tomography, and ultrasound is used for blood flow assessment. In two cases of PSS-related hepatic encephalopathy, we used time-resolved 3D cine phase-contrast (4D-flow) magnetic resonance imaging (MRI) to assess blood flow before and after shunt embolization. Before the intervention, blood flow in the main trunk of the superior mesenteric vein was mostly hepatofugal. However, post-interventional 4D-flow MRI revealed hepatopetal superior mesenteric vein flow with significantly increased portal vein blood flow. 4D-flow MRI is an ideal adjunct to Doppler ultrasonography, allowing for objective and visual assessment of morphology and blood flow of the portal venous system, including PSSs, and is useful in determining the indications for, and outcome of, PSS embolization.
Collapse
Affiliation(s)
- Ryota Hyodo
- Department of Radiology, Nagoya University Graduate School of Medicine, Showa-ku, Nagoya, Japan
| | - Yasuo Takehara
- Department of Radiology, Nagoya University Graduate School of Medicine, Showa-ku, Nagoya, Japan.,Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Showa-ku, Nagoya, Japan
| | - Takashi Mizuno
- Department of Medical Radiological Technology, Nagoya University Hospital, Showa-ku, Nagoya, Japan
| | - Kazushige Ichikawa
- Department of Medical Radiological Technology, Nagoya University Hospital, Showa-ku, Nagoya, Japan
| | - Yoji Ishizu
- Department of Gastroenterology and Hepatology, Nagoya University Graduate School of Medicine, Showa-ku, Nagoya, Japan
| | - Masataka Sugiyama
- Department of Radiology, Nagoya University Graduate School of Medicine, Showa-ku, Nagoya, Japan.,Department of Fundamental Development for Advanced Low Invasive Diagnostic Imaging, Nagoya University Graduate School of Medicine, Showa-ku, Nagoya, Japan
| | - Shinji Naganawa
- Department of Radiology, Nagoya University Graduate School of Medicine, Showa-ku, Nagoya, Japan
| |
Collapse
|
28
|
Heidari Pahlavian S, Cen SY, Bi X, Wang DJJ, Chui HC, Yan L. Assessment of carotid stiffness by measuring carotid pulse wave velocity using a single-slice oblique-sagittal phase-contrast MRI. Magn Reson Med 2021; 86:442-455. [PMID: 33543788 DOI: 10.1002/mrm.28677] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 12/14/2020] [Accepted: 12/18/2020] [Indexed: 11/06/2022]
Abstract
PURPOSE Increased arterial stiffness has been shown to be one of the earliest markers of cerebrovascular dysfunction. As a surrogate marker of arterial stiffness, pulse wave velocity (PWV) quantifications are generally carried out on central and peripheral arteries. The purpose of this study was to develop and evaluate an MRI approach to assess carotid stiffness by measuring carotid PWV (cPWV) using a fast oblique-sagittal phase-contrast MRI sequence. METHODS In 29 volunteers, a single-slice oblique-sagittal phase-contrast MRI sequence with retrospective cardiac gating was used to quantify blood velocity waveforms along a vessel segment covering the common carotid artery (CCA) and the internal carotid artery (ICA). The CCA-ICA segment length was measured from a region of interest selected on the magnitude image. Phase-contrast MRI-measured velocities were also used to quantify the ICA pulsatility index along with cPWV quantification. RESULTS The mean value of cPWV calculated using the middle upslope area algorithm was 2.86 ± 0.71 and 3.97 ± 1.14 m/s in young and elderly subjects, respectively. Oblique-sagittal phase-contrast MRI-derived cPWV measurements showed excellent intrascan and interscan repeatability. cPWV and ICA pulsatility index were significantly greater in older subjects compared to those in the young subjects (P < .01 and P = .01, respectively). Also, increased cPWV values were associated with elevated systolic blood pressure (β = 0.05, P = .03). CONCLUSION This study demonstrated that oblique-sagittal phase-contrast MRI is a feasible technique for the quantification of both cPWV and ICA pulsatility index and showed their potential utility in evaluating cerebroarterial aging and age-related neurovascular disorders.
Collapse
Affiliation(s)
- Soroush Heidari Pahlavian
- USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.,Department of Neurology, University of Southern California, Los Angeles, California, USA
| | - Steven Yong Cen
- Department of Neurology, University of Southern California, Los Angeles, California, USA
| | - Xiaoming Bi
- Siemens Medical Solutions USA, Inc., Los Angeles, California, USA
| | - Danny J J Wang
- USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.,Department of Neurology, University of Southern California, Los Angeles, California, USA
| | - Helena Chang Chui
- Department of Neurology, University of Southern California, Los Angeles, California, USA
| | - Lirong Yan
- USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.,Department of Neurology, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
29
|
Geiger J, Callaghan FM, Burkhardt BEU, Valsangiacomo Buechel ER, Kellenberger CJ. Additional value and new insights by four-dimensional flow magnetic resonance imaging in congenital heart disease: application in neonates and young children. Pediatr Radiol 2021; 51:1503-1517. [PMID: 33313980 PMCID: PMC8266722 DOI: 10.1007/s00247-020-04885-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 08/08/2020] [Accepted: 10/12/2020] [Indexed: 12/12/2022]
Abstract
Cardiovascular MRI has become an essential imaging modality in children with congenital heart disease (CHD) in the last 15-20 years. With use of appropriate sequences, it provides important information on cardiovascular anatomy, blood flow and function for initial diagnosis and post-surgical or -interventional monitoring in children. Although considered as more sophisticated and challenging than CT, in particular in neonates and infants, MRI is able to provide information on intra- and extracardiac haemodynamics, in contrast to CT. In recent years, four-dimensional (4-D) flow MRI has emerged as an additional MR technique for retrospective assessment and visualisation of blood flow within the heart and any vessel of interest within the acquired three-dimensional (3-D) volume. Its application in young children requires special adaptations for the smaller vessel size and faster heart rate compared to adolescents or adults. In this article, we provide an overview of 4-D flow MRI in various types of complex CHD in neonates and infants to demonstrate its potential indications and beneficial application for optimised individual cardiovascular assessment. We focus on its application in clinical routine cardiovascular workup and, in addition, show some examples with pathologies other than CHD to highlight that 4-D flow MRI yields new insights in disease understanding and therapy planning. We shortly review the essentials of 4-D flow data acquisition, pre- and post-processing techniques in neonates, infants and young children. Finally, we conclude with some details on accuracy, limitations and pitfalls of the technique.
Collapse
Affiliation(s)
- Julia Geiger
- Department of Diagnostic Imaging, University Children's Hospital Zürich, Steinwiesstr 75, 8032, Zürich, Switzerland. .,Children's Research Centre, University Children's Hospital Zürich, Zürich, Switzerland.
| | - Fraser M. Callaghan
- Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland ,Center for MR research, University Children’s Hospital Zürich, Zürich, Switzerland
| | - Barbara E. U. Burkhardt
- Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland ,Department of Pediatric Cardiology, University Hospital Zürich, Zürich, Switzerland
| | - Emanuela R. Valsangiacomo Buechel
- Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland ,Department of Pediatric Cardiology, University Hospital Zürich, Zürich, Switzerland
| | - Christian J. Kellenberger
- Department of Diagnostic Imaging, University Children’s Hospital Zürich, Steinwiesstr 75, 8032 Zürich, Switzerland ,Children’s Research Centre, University Children’s Hospital Zürich, Zürich, Switzerland
| |
Collapse
|
30
|
Riedel C, Lenz A, Fischer L, Li J, Piecha F, Kluwe J, Adam G, Bannas P. Abdominal Applications of 4D Flow MRI. ROFO-FORTSCHR RONTG 2020; 193:388-398. [PMID: 33264806 DOI: 10.1055/a-1271-7405] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND Four-dimensional flow magnetic resonance imaging (4D flow MRI) provides volumetric and time-resolved visualization and quantification of blood flow. This review presents an overview of possible applications of 4D flow MRI for non-invasive assessment of abdominal hemodynamics. METHOD This review is based on the authors' experience and the current literature. A PubMed database literature research was performed in December 2019 focusing on abdominal applications of 4D flow MRI. We illustrated the review with exemplary figures and movies of clinical cases from our institution. RESULTS AND CONCLUSION 4D flow MRI offers the possibility of comprehensive assessment of abdominal blood flows in different vascular territories and organ systems. Results of recent studies indicate that 4D flow MRI improves understanding of altered hemodynamics in patients with abdominal disease and may be useful for monitoring therapeutic response. Future studies with larger cohorts aiming to integrate 4D flow MRI in the clinical routine setting are needed. KEY POINTS · 4D flow MRI enables comprehensive visualization of the complex abdominal vasculature. · 4D flow MRI enables quantification of abdominal blood flow velocities and flow rates. · 4D flow MRI may enable deeper understanding of altered hemodynamics in abdominal disease. · Further validation studies are needed prior to broad distribution of abdominal 4D flow MRI. CITATION FORMAT · Riedel C, Lenz A, Fischer L et al. Abdominal Applications of 4D Flow MRI. Fortschr Röntgenstr 2021; 193: 388 - 398.
Collapse
Affiliation(s)
- Christoph Riedel
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Alexander Lenz
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Lutz Fischer
- Department of Visceral Transplantation, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jun Li
- Department of Visceral Transplantation, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Feilix Piecha
- I. Department of Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Johannes Kluwe
- I. Department of Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Gerhard Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Peter Bannas
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
31
|
Pathrose A, Ma L, Berhane H, Scott MB, Chow K, Forman C, Jin N, Serhal A, Avery R, Carr J, Markl M. Highly accelerated aortic 4D flow MRI using compressed sensing: Performance at different acceleration factors in patients with aortic disease. Magn Reson Med 2020; 85:2174-2187. [PMID: 33107141 DOI: 10.1002/mrm.28561] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 09/29/2020] [Accepted: 09/30/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE To systematically assess the feasibility and performance of a highly accelerated compressed sensing (CS) 4D flow MRI framework at three different acceleration factors (R) for the quantification of aortic flow dynamics and wall shear stress (WSS) in patients with aortic disease. METHODS Twenty patients with aortic disease (58 ± 15 y old; 19 M) underwent four 4D flow scans: one conventional (GRAPPA, R = 2) and three CS 4D flows with R = 5.7, 7.7, and 10.2. All scans were acquired with otherwise equivalent imaging parameters on a 1.5T scanner. Peak-systolic velocity (Vmax ), peak flow (Qmax ), and net flow (Qnet ) were quantified at the ascending aorta (AAo), arch, and descending aorta (DAo). WSS was calculated at six regions within the AAo and arch. RESULTS Mean scan times for the conventional and CS 4D flows with R = 5.7, 7.7, and 10.2 were 9:58 ± 2:58 min, 3:40 ± 1:19 min, 2:50 ± 0:56 min, and 2:05 ± 0:42 min, respectively. Vmax , Qmax , and Qnet were significantly underestimated by all CS protocols (underestimation ≤ -7%, -9%, and -10% by CS, R = 5.7, 7.7, and 10.2, respectively). WSS measurements showed the highest underestimation by all CS protocols (underestimation ≤ -9%, -12%, and -14% by CS, R = 5.7, 7.7, and 10.2). CONCLUSIONS Highly accelerated aortic CS 4D flow at R = 5.7, 7.7, and 10.2 showed moderate agreement with the conventional 4D flow, despite systematically underestimating various hemodynamic parameters. The shortened scan time may enable the clinical translation of CS 4D flow, although potential hemodynamic underestimation should be considered when interpreting the results.
Collapse
Affiliation(s)
- Ashitha Pathrose
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Liliana Ma
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | - Haben Berhane
- Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital of Chicago, Chicago, Illinois, USA
| | - Michael B Scott
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | - Kelvin Chow
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, Illinois, USA
| | | | - Ning Jin
- Cardiovascular MR R&D, Siemens Medical Solutions USA, Inc., Chicago, Illinois, USA
| | - Ali Serhal
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Ryan Avery
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - James Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, Northwestern University, Evanston, Illinois, USA
| |
Collapse
|
32
|
Strecker C, Krafft AJ, Kaufhold L, Hüllebrandt M, Weber S, Ludwig U, Wolkewitz M, Hennemuth A, Hennig J, Harloff A. Carotid geometry is an independent predictor of wall thickness - a 3D cardiovascular magnetic resonance study in patients with high cardiovascular risk. J Cardiovasc Magn Reson 2020; 22:67. [PMID: 32912285 PMCID: PMC7488078 DOI: 10.1186/s12968-020-00657-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 07/28/2020] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The posterior wall of the proximal internal carotid artery (ICA) is the predilection site for the development of stenosis. To optimally prevent stroke, identification of new risk factors for plaque progression is of high interest. Therefore, we studied the impact of carotid geometry and wall shear stress on cardiovascular magnetic resonance (CMR)-depicted wall thickness in the ICA of patients with high cardiovascular disease risk. METHODS One hundred twenty-one consecutive patients ≥50 years with hypertension, ≥1 additional cardiovascular risk factor and ICA plaque ≥1.5 mm thickness and < 50% stenosis were prospectively included. High-resolution 3D-multi-contrast (time of flight, T1, T2, proton density) and 4D flow CMR were performed for the assessment of morphological (bifurcation angle, ICA/common carotid artery (CCA) diameter ratio, tortuosity, and wall thickness) and hemodynamic parameters (absolute/systolic wall shear stress (WSS), oscillatory shear index (OSI)) in 242 carotid bifurcations. RESULTS We found lower absolute/systolic WSS, higher OSI and increased wall thickness in the posterior compared to the anterior wall of the ICA bulb (p < 0.001), whereas this correlation disappeared in ≥10% stenosis. Higher carotid tortuosity (regression coefficient = 0.764; p < 0.001) and lower ICA/CCA diameter ratio (regression coefficient = - 0.302; p < 0.001) were independent predictors of increased wall thickness even after adjustment for cardiovascular risk factors. This association was not found for bifurcation angle, WSS or OSI in multivariate regression analysis. CONCLUSIONS High carotid tortuosity and low ICA diameter were independent predictors for wall thickness of the ICA bulb in this cross-sectional study, whereas this association was not present for WSS or OSI. Thus, consideration of geometric parameters of the carotid bifurcation could be helpful to identify patients at increased risk of carotid plaque generation. However, this association and the potential benefit of WSS measurement need to be further explored in a longitudinal study.
Collapse
Affiliation(s)
- Christoph Strecker
- Department of Neurology and Neurophysiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacherstrasse 64, 79106 Freiburg, Germany
| | - Axel Joachim Krafft
- Department of Radiology - Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Lilli Kaufhold
- Fraunhofer MEVIS, Bremen, Germany
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Markus Hüllebrandt
- Fraunhofer MEVIS, Bremen, Germany
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Susanne Weber
- Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany
| | - Ute Ludwig
- Department of Radiology - Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Martin Wolkewitz
- Institute of Medical Biometry and Statistics, Faculty of Medicine and Medical Center, University of Freiburg, Freiburg, Germany
| | - Anja Hennemuth
- Fraunhofer MEVIS, Bremen, Germany
- Institute for Imaging Science and Computational Modelling in Cardiovascular Medicine, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Jürgen Hennig
- Department of Radiology - Medical Physics, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Andreas Harloff
- Department of Neurology and Neurophysiology, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Breisacherstrasse 64, 79106 Freiburg, Germany
| |
Collapse
|
33
|
Jaeger E, Sonnabend K, Schaarschmidt F, Maintz D, Weiss K, Bunck AC. Compressed-sensing accelerated 4D flow MRI of cerebrospinal fluid dynamics. Fluids Barriers CNS 2020; 17:43. [PMID: 32677977 PMCID: PMC7364783 DOI: 10.1186/s12987-020-00206-3] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Accepted: 07/06/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND 4D flow magnetic resonance imaging (MRI) of CSF can make an important contribution to the understanding of hydrodynamic changes in various neurological diseases but remains limited in clinical application due to long acquisition times. The aim of this study was to evaluate the accuracy of compressed SENSE accelerated MRI measurements of the spinal CSF flow. METHODS In 20 healthy subjects 4D flow MRI of the CSF in the cervical spine was acquired using compressed sensitivity encoding [CSE, a combination of compressed sensing and parallel imaging (SENSE) provided by the manufacturer] with acceleration factors between 4 and 10. A conventional scan using SENSE was used as reference. Extracted parameters were peak velocity, absolute net flow, forward flow and backward flow. Bland-Altman analysis was performed to determine the scan-rescan reproducibility and the agreement between SENSE and compressed SENSE. Additionally, a time accumulated flow error was calculated. In one additional subject flow of the spinal canal at the level of the entire spinal cord was assessed. RESULTS Averaged acquisition times were 10:21 min (SENSE), 9:31 min (CSE4), 6:25 min (CSE6), 4:53 min (CSE8) and 3:51 min (CSE10). Acquisition of the CSF flow surrounding the entire spinal cord took 14:40 min. Bland-Altman analysis showed good agreement for peak velocity, but slight overestimations for absolute net flow, forward flow and backward flow (< 1 ml/min) in CSE4-8. Results of the accumulated flow error were similar for CSE4 to CSE8. CONCLUSION A quantitative analysis of acceleration factors CSE4-10 showed that CSE with an acceleration factor up to 6 is feasible. This allows a scan time reduction of 40% and enables the acquisition and analysis of the CSF flow dynamics surrounding the entire spinal cord within a clinically acceptable scan time.
Collapse
Affiliation(s)
- Elena Jaeger
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Kristina Sonnabend
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - Frank Schaarschmidt
- Institute of Cell Biology and Biophysics, Biostatistics Department, Leibniz University Hannover, Hannover, Germany
| | - David Maintz
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Kilian Weiss
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.,Philips GmbH, Hamburg, Germany
| | - Alexander C Bunck
- Department of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| |
Collapse
|
34
|
Theek B, Nolte T, Pantke D, Schrank F, Gremse F, Schulz V, Kiessling F. Emerging methods in radiology. Radiologe 2020; 60:41-53. [PMID: 32430576 DOI: 10.1007/s00117-020-00696-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Imaging modalities have developed rapidly in recent decades. In addition to improved resolution as well as whole-body and faster image acquisition, the possibilities of functional and molecular examination of tissue pathophysiology have had a decisive influence on imaging diagnostics and provided ground-breaking knowledge. Many promising approaches are currently being pursued to increase the application area of devices and contrast media and to improve their sensitivity and quantitative informative value. These are complemented by new methods of data processing, multiparametric data analysis, and integrated diagnostics. The aim of this article is to provide an overview of technological innovations that will enrich clinical imaging in the future, and to highlight the resultant diagnostic options. These relate to the established imaging methods such as CT, MRI, ultrasound, PET, and SPECT but also to new methods such as magnetic particle imaging (MPI), optical imaging, and photoacoustics. In addition, approaches to radiomic image evaluation are explained and the chances and difficulties for their broad clinical introduction are discussed. The potential of imaging to describe pathophysiological relationships in ever increasing detail, both at whole-body and tissue level, can in future be used to better understand the mechanistic effect of drugs, to preselect patients to therapies, and to improve monitoring of therapy success. Consequently, the use of interdisciplinary integrated diagnostics will greatly change and enrich the profession of radiologists.
Collapse
Affiliation(s)
- B Theek
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Forckenbeckstraße 55, 52074, Aachen, Germany.,Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany
| | - T Nolte
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - D Pantke
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - F Schrank
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - F Gremse
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - V Schulz
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Forckenbeckstraße 55, 52074, Aachen, Germany.,Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany.,Comprehensive Diagnostic Center Aachen (CDCA), University Hospital RWTH Aachen, Aachen, Germany
| | - F Kiessling
- Institute for Experimental Molecular Imaging, Medical Faculty, RWTH Aachen International University, Forckenbeckstraße 55, 52074, Aachen, Germany. .,Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany. .,Comprehensive Diagnostic Center Aachen (CDCA), University Hospital RWTH Aachen, Aachen, Germany.
| |
Collapse
|
35
|
Gottwald LM, Peper ES, Zhang Q, Coolen BF, Strijkers GJ, Nederveen AJ, van Ooij P. Pseudo-spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k-t principal component analysis. NMR IN BIOMEDICINE 2020; 33:e4255. [PMID: 31957927 PMCID: PMC7079056 DOI: 10.1002/nbm.4255] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 06/10/2023]
Abstract
INTRODUCTION Time-resolved three-dimensional phase contrast MRI (4D flow) of aortic blood flow requires acceleration to reduce scan time. Two established techniques for highly accelerated 4D flow MRI are k-t principal component analysis (k-t PCA) and compressed sensing (CS), which employ either regular or random k-space undersampling. The goal of this study was to gain insights into the quantitative differences between k-t PCA- and CS-derived aortic blood flow, especially for high temporal resolution CS 4D flow MRI. METHODS The scan protocol consisted of both k-t PCA and CS accelerated 4D flow MRI, as well as a 2D flow reference scan through the ascending aorta acquired in 15 subjects. 4D flow scans were accelerated with factor R = 8. For CS accelerated scans, we used a pseudo-spiral Cartesian sampling scheme, which could additionally be reconstructed at higher temporal resolution, resulting in R = 13. 4D flow data were compared with the 2D flow scan in terms of flow, peak flow and stroke volume. A 3D peak systolic voxel-wise velocity and wall shear stress (WSS) comparison between k-t PCA and CS 4D flow was also performed. RESULTS The mean difference in flow/peak flow/stroke volume between the 2D flow scan and the 4D flow CS with R = 8 and R = 13 was 4.2%/9.1%/3.0% and 5.3%/7.1%/1.9%, respectively, whereas for k-t PCA with R = 8 the difference was 9.7%/25.8%/10.4%. In the voxel-by-voxel 4D flow comparison we found 13.6% and 3.5% lower velocity and WSS values of k-t PCA compared with CS with R = 8, and 15.9% and 5.5% lower velocity and WSS values of k-t PCA compared with CS with R = 13. CONCLUSION Pseudo-spiral accelerated 4D flow acquisitions in combination with CS reconstruction provides a flexible choice of temporal resolution. We showed that our proposed strategy achieves better agreement in flow values with 2D reference scans compared with using k-t PCA accelerated acquisitions.
Collapse
Affiliation(s)
- Lukas M. Gottwald
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Eva S. Peper
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Qinwei Zhang
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Bram F. Coolen
- Department of Biomedical Engineering and Physics, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Gustav J. Strijkers
- Department of Biomedical Engineering and Physics, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Aart J. Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| |
Collapse
|