1
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
2
|
Marques-Almeida T, Lanceros-Mendez S, Ribeiro C. State of the Art and Current Challenges on Electroactive Biomaterials and Strategies for Neural Tissue Regeneration. Adv Healthc Mater 2024; 13:e2301494. [PMID: 37843074 DOI: 10.1002/adhm.202301494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Revised: 09/22/2023] [Indexed: 10/17/2023]
Abstract
The loss or failure of an organ/tissue stands as one of the healthcare system's most prevalent, devastating, and costly challenges. Strategies for neural tissue repair and regeneration have received significant attention due to their particularly strong impact on patients' well-being. Many research efforts are dedicated not only to control the disease symptoms but also to find solutions to repair the damaged tissues. Neural tissue engineering (TE) plays a key role in addressing this problem and significant efforts are being carried out to develop strategies for neural repair treatment. In the last years, active materials allowing to tune cell-materials interaction are being increasingly used, representing a recent paradigm in TE applications. Among the most important stimuli influencing cell behavior are the electrical and mechanical ones. In this way, materials with the ability to provide this kind of stimuli to the neural cells seem to be appropriate to support neural TE. In this scope, this review summarizes the different biomaterials types used for neural TE, highlighting the relevance of using active biomaterials and electrical stimulation. Furthermore, this review provides not only a compilation of the most relevant studies and results but also strategies for novel and more biomimetic approaches for neural TE.
Collapse
Affiliation(s)
- Teresa Marques-Almeida
- Physics Centre of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, 4710-057, Portugal
- LaPMET - Laboratory of Physics for Materials and Emergent Technologies, University of Minho, Braga, 4710-057, Portugal
| | - Senentxu Lanceros-Mendez
- Physics Centre of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, 4710-057, Portugal
- LaPMET - Laboratory of Physics for Materials and Emergent Technologies, University of Minho, Braga, 4710-057, Portugal
- BCMaterials, Basque Center for Materials, Applications and Nanostructures, UPV/EHU Science Park, Leioa, 48940, Spain
- IKERBASQUE, Basque Foundation for Science, Bilbao, 48009, Spain
| | - Clarisse Ribeiro
- Physics Centre of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, 4710-057, Portugal
- LaPMET - Laboratory of Physics for Materials and Emergent Technologies, University of Minho, Braga, 4710-057, Portugal
| |
Collapse
|
3
|
Burton A, Wang Z, Song D, Tran S, Hanna J, Ahmad D, Bakall J, Clausen D, Anderson J, Peralta R, Sandepudi K, Benedetto A, Yang E, Basrai D, Miller LE, Tresch MC, Gutruf P. Fully implanted battery-free high power platform for chronic spinal and muscular functional electrical stimulation. Nat Commun 2023; 14:7887. [PMID: 38036552 PMCID: PMC10689769 DOI: 10.1038/s41467-023-43669-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Accepted: 11/16/2023] [Indexed: 12/02/2023] Open
Abstract
Electrical stimulation of the neuromuscular system holds promise for both scientific and therapeutic biomedical applications. Supplying and maintaining the power necessary to drive stimulation chronically is a fundamental challenge in these applications, especially when high voltages or currents are required. Wireless systems, in which energy is supplied through near field power transfer, could eliminate complications caused by battery packs or external connections, but currently do not provide the harvested power and voltages required for applications such as muscle stimulation. Here, we introduce a passive resonator optimized power transfer design that overcomes these limitations, enabling voltage compliances of ± 20 V and power over 300 mW at device volumes of 0.2 cm2, thereby improving power transfer 500% over previous systems. We show that this improved performance enables multichannel, biphasic, current-controlled operation at clinically relevant voltage and current ranges with digital control and telemetry in freely behaving animals. Preliminary chronic results indicate that implanted devices remain operational over 6 weeks in both intact and spinal cord injured rats and are capable of producing fine control of spinal and muscle stimulation.
Collapse
Affiliation(s)
- Alex Burton
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Zhong Wang
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Dan Song
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Sam Tran
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Jessica Hanna
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Dhrubo Ahmad
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Jakob Bakall
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - David Clausen
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Jerry Anderson
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Roberto Peralta
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA
| | - Kirtana Sandepudi
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
| | - Alex Benedetto
- Interdepartmental Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Ethan Yang
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Diya Basrai
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
| | - Lee E Miller
- Department of Neuroscience, Northwestern University, Chicago, IL, 60611, USA
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA
- Interdepartmental Neuroscience, Northwestern University, Chicago, IL, 60611, USA
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, 60611, USA
| | - Matthew C Tresch
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, 60208, USA.
- Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL, 60611, USA.
- Shirley Ryan AbilityLab, Chicago, IL, 60611, USA.
| | - Philipp Gutruf
- Department of Biomedical Engineering, University of Arizona, Tucson, AZ, 85721, USA.
- Bio5 Institute and Department of Neurology, University of Arizona, Tucson, AZ, 85721, USA.
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ, 85721, USA.
| |
Collapse
|
4
|
Wang D, Xing S, Peng F, Zhang X, Tan J, Hao X, Qiao Y, Ge N, Liu X. Microenvironment-responsive electrocution of tumor and bacteria by implants modified with degenerate semiconductor film. Bioact Mater 2023; 20:472-488. [PMID: 35800406 PMCID: PMC9249615 DOI: 10.1016/j.bioactmat.2022.06.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 06/05/2022] [Accepted: 06/10/2022] [Indexed: 11/23/2022] Open
Abstract
Implantable biomaterials are widely used in the curative resection and palliative treatment of various types of cancers. However, cancer residue around the implants usually leads to treatment failure with cancer reoccurrence. Postoperation chemotherapy and radiation therapy are widely applied to clear the residual cancer cells but induce serious side effects. It is urgent to develop advanced therapy to minimize systemic toxicity while maintaining efficient cancer-killing ability. Herein, we report a degenerate layered double hydroxide (LDH) film modified implant, which realizes microenvironment-responsive electrotherapy. The film can gradually transform into a nondegenerate state and release holes. When in contact with tumor cells or bacteria, the film quickly transforms into a nondegenerate state and releases holes at a high rate, rendering the "electrocution" of tumor cells and bacteria. However, when placed in normal tissue, the hole release rate of the film is much slower, thus, causing little harm to normal cells. Therefore, the constructed film can intelligently identify and meet the physiological requirements promptly. In addition, the transformation between degenerate and nondegenerate states of LDH films can be cycled by electrical charging, so their selective and dynamic physiological functions can be artificially adjusted according to demand.
Collapse
Affiliation(s)
- Donghui Wang
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
- School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Shun Xing
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Feng Peng
- Department of Orthopedics, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou, Guangdong, 510080, China
| | - Xianming Zhang
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Ji Tan
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Xueqing Hao
- School of Health Sciences and Biomedical Engineering, Hebei University of Technology, Tianjin, 300130, China
| | - Yuqin Qiao
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
| | - Naijian Ge
- Intervention Center, Eastern Hepatobiliary Surgery Hospital, The Third Affiliated Hospital of Naval Medical University, Shanghai, 200438, China
| | - Xuanyong Liu
- State Key Laboratory of High Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China
- School of Chemistry and Materials Science, Hangzhou Institute for Advanced Study, University of Chinese Academy of Sciences, 1 Sub-lane Xiangshan, Hangzhou, 310024, China
| |
Collapse
|
5
|
Abstract
The design and implementation of a piezoelectric energy-harvesting system, aimed at stimulating the Tibialis anterior muscle to aid patients struggling with a foot drop disability, are investigated. A physical prototype designed to be installed inside a shoe sole, consisting of an energy-harvesting unit along with a power-management circuit and a functional electrical-stimulation circuit, is fabricated. The piezoelectric energy harvester (PEH) incorporated six layers of Polyvinylidene-Fluoride sheets to achieve a mean-charge generation of 65.25 μC/step and a peak power of 10.76 mW/step. A peak voltage of +80.0 V generation was achieved during a stomping motion. The electrical systems store, convert, and deploy 60 mA electric pulses at the desired frequencies to the target muscle. The finalized prototype is best-suited to prolong the duration of the charged batteries whilst in use. In a practical sense, it should be used alongside external-power sources to recharge the batteries installed in a foot drop stimulation device. The PEH in its current state is fully capable of solely powering blood pressure sensors, glucose meters, or activity trackers.
Collapse
|
6
|
Rahman MA, Tharu NS, Gustin SM, Zheng YP, Alam M. Trans-Spinal Electrical Stimulation Therapy for Functional Rehabilitation after Spinal Cord Injury: Review. J Clin Med 2022; 11:1550. [PMID: 35329875 PMCID: PMC8954138 DOI: 10.3390/jcm11061550] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 03/04/2022] [Accepted: 03/09/2022] [Indexed: 01/25/2023] Open
Abstract
Spinal cord injury (SCI) is one of the most debilitating injuries in the world. Complications after SCI, such as respiratory issues, bowel/bladder incontinency, pressure ulcers, autonomic dysreflexia, spasticity, pain, etc., lead to immense suffering, a remarkable reduction in life expectancy, and even premature death. Traditional rehabilitations for people with SCI are often insignificant or ineffective due to the severity and complexity of the injury. However, the recent development of noninvasive electrical neuromodulation treatments to the spinal cord have shed a ray of hope for these individuals to regain some of their lost functions, a reduction in secondary complications, and an improvement in their life quality. For this review, 250 articles were screened and about 150 were included to summarize the two most promising noninvasive spinal cord electrical stimulation methods of SCI rehabilitation treatment, namely, trans-spinal direct current stimulation (tsDCS) and trans-spinal pulsed current stimulation (tsPCS). Both treatments have demonstrated good success in not only improving the sensorimotor function, but also autonomic functions. Due to the noninvasive nature and lower costs of these treatments, in the coming years, we expect these treatments to be integrated into regular rehabilitation therapies worldwide.
Collapse
Affiliation(s)
- Md. Akhlasur Rahman
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China; (M.A.R.); (N.S.T.); (Y.-P.Z.)
- Centre for the Rehabilitation of the Paralysed (CRP), Savar Union 1343, Bangladesh
| | - Niraj Singh Tharu
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China; (M.A.R.); (N.S.T.); (Y.-P.Z.)
| | - Sylvia M. Gustin
- NeuroRecovery Research Hub, School of Psychology, University of New South Wales, Sydney, NSW 2052, Australia;
- Centre for Pain IMPACT, Neuroscience Research Australia, Sydney, NSW 2031, Australia
| | - Yong-Ping Zheng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China; (M.A.R.); (N.S.T.); (Y.-P.Z.)
| | - Monzurul Alam
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China; (M.A.R.); (N.S.T.); (Y.-P.Z.)
- NeuroRecovery Research Hub, School of Psychology, University of New South Wales, Sydney, NSW 2052, Australia;
- Centre for Pain IMPACT, Neuroscience Research Australia, Sydney, NSW 2031, Australia
| |
Collapse
|
7
|
Owida HA, Al-Nabulsi JI, Turab NM, Alnaimat F, Rababah H, Shakour MY. Autocharging Techniques for Implantable Medical Applications. Int J Biomater 2021; 2021:6074657. [PMID: 34712329 PMCID: PMC8548125 DOI: 10.1155/2021/6074657] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Accepted: 10/01/2021] [Indexed: 11/17/2022] Open
Abstract
Implantable devices have successfully proven their reliability and efficiency in the medical field due to their immense support in a variety of aspects concerning the monitoring of patients and treatment in many ways. Moreover, they assist the medical field in disease diagnosis and prevention. However, the devices' power sources rely on batteries, and with this reliance, comes certain complications. For example, their depletion may lead to surgical interference or leakage into the human body. Implicit studies have found ways to reduce the battery size or in some cases to eliminate its use entirely; these studies suggest the use of biocompatible harvesters that can support the device consumption by generating power. Harvesting mechanisms can be executed using a variety of biocompatible materials, namely, piezoelectric and triboelectric nanogenerators, biofuel cells, and environmental sources. As with all methods for implementing biocompatible harvesters, some of them are low in terms of power consumption and some are dependent on the device and the place of implantation. In this review, we discuss the application of harvesters into implantable devices and evaluate the different materials and methods and examine how new and improved circuits will help in assisting the generators to sustain the function of medical devices.
Collapse
Affiliation(s)
- Hamza Abu Owida
- Medical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, Amman 19328, Jordan
| | - Jamal I. Al-Nabulsi
- Medical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, Amman 19328, Jordan
| | - Nidal M. Turab
- Department of Networks and Information Security, Faculty of Information Technology, Al-Ahliyya Amman University, Amman 19328, Jordan
| | - Feras Alnaimat
- Medical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, Amman 19328, Jordan
| | - Hana Rababah
- Electrical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, Amman 19328, Jordan
| | - Murad Y. Shakour
- Medical Engineering Department, Faculty of Engineering, Al-Ahliyya Amman University, Amman 19328, Jordan
| |
Collapse
|
8
|
Singer A, Robinson JT. Wireless Power Delivery Techniques for Miniature Implantable Bioelectronics. Adv Healthc Mater 2021; 10:e2100664. [PMID: 34114368 PMCID: PMC8754427 DOI: 10.1002/adhm.202100664] [Citation(s) in RCA: 43] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 05/11/2021] [Indexed: 12/14/2022]
Abstract
Progress in implanted bioelectronic technology offers the opportunity to develop more effective tools for personalized electronic medicine. While there are numerous clinical and pre-clinical applications for these devices, power delivery to these systems can be challenging. Wireless battery-free devices offer advantages such as a smaller and lighter device footprint and reduced failures and infections by eliminating lead wires. However, with the development of wireless technologies, there are fundamental tradeoffs between five essential factors: power, miniaturization, depth, alignment tolerance, and transmitter distance, while still allowing devices to work within safety limits. These tradeoffs mean that multiple forms of wireless power transfer are necessary for different devices to best meet the needs for a given biological target. Here six different types of wireless power transfer technologies used in bioelectronic implants-inductive coupling, radio frequency, mid-field, ultrasound, magnetoelectrics, and light-are reviewed in context of the five tradeoffs listed above. This core group of wireless power modalities is then used to suggest possible future bioelectronic technologies and their biological applications.
Collapse
Affiliation(s)
- Amanda Singer
- Department of Electrical and Computer EngineeringRice University6100 Main StHoustonTX77005USA
| | - Jacob T. Robinson
- Department of Electrical and Computer EngineeringRice University6100 Main StHoustonTX77005USA
| |
Collapse
|
9
|
Wang D, Tan J, Zhu H, Mei Y, Liu X. Biomedical Implants with Charge-Transfer Monitoring and Regulating Abilities. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2004393. [PMID: 34166584 PMCID: PMC8373130 DOI: 10.1002/advs.202004393] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 05/12/2021] [Indexed: 05/06/2023]
Abstract
Transmembrane charge (ion/electron) transfer is essential for maintaining cellular homeostasis and is involved in many biological processes, from protein synthesis to embryonic development in organisms. Designing implant devices that can detect or regulate cellular transmembrane charge transfer is expected to sense and modulate the behaviors of host cells and tissues. Thus, charge transfer can be regarded as a bridge connecting living systems and human-made implantable devices. This review describes the mode and mechanism of charge transfer between organisms and nonliving materials, and summarizes the strategies to endow implants with charge-transfer regulating or monitoring abilities. Furthermore, three major charge-transfer controlling systems, including wired, self-activated, and stimuli-responsive biomedical implants, as well as the design principles and pivotal materials are systematically elaborated. The clinical challenges and the prospects for future development of these implant devices are also discussed.
Collapse
Affiliation(s)
- Donghui Wang
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
- School of Materials Science and EngineeringHebei University of TechnologyTianjin300130China
| | - Ji Tan
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
| | - Hongqin Zhu
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
- Department of Materials ScienceFudan UniversityShanghai200433China
| | - Yongfeng Mei
- Department of Materials ScienceFudan UniversityShanghai200433China
| | - Xuanyong Liu
- State Key Laboratory of High Performance Ceramics and Superfine MicrostructureShanghai Institutes of CeramicsChinese Academy of SciencesShanghai200050China
- School of Chemistry and Materials ScienceHangzhou Institute for Advanced StudyUniversity of Chinese Academy of SciencesHangzhou310024China
| |
Collapse
|
10
|
Song L, Zhang J, Liu J. ANOVA-Based Analysis of Early Blood Transfusions on Hemodynamics with Severely Injured Trauma Using Bedside Ultrasound Imaging. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:5263454. [PMID: 34336156 PMCID: PMC8321714 DOI: 10.1155/2021/5263454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 07/14/2021] [Indexed: 11/17/2022]
Abstract
The focus of the study was to quantitatively analyze the influence of early massive blood transfusions (MBTs) on the hemodynamics and prognostic living quality of patients with severely injured trauma. 114 patients with severely injured trauma were enrolled into MBT group (67 cases) and nonmassive blood transfusions (NBT) group (47 cases) according to whether they accepted MBTs within 24 hours after the admission. All patients had bedside ultrasound technology scanning. Furthermore, the indexes were calculated for inferior vena cava (IVC), peripheral arteries, and heart. The prognostic deaths were recorded. It was found that, in the MBT group, the mortality was lower (7.55% vs. 24.23%) (P < 0.05), and these indexes were higher for the IVC expansion (IVCE), the respiration variation index (RVI) of IVC (ΔIVC2), the peak flow velocity RVI of brachial artery (ΔVpeakBA), femoral artery (ΔVpeakFA), left ventricular outflow tract (ΔVpeakL), and aorta (ΔVpeakAO), as well as peak flow velocity time integral RVI of aorta (ΔVTIAO) (P < 0.05). In conclusion, early MBTs can elevate survival rate and prognostic living quality and alleviate the atrophy degree of IVC, peripheral artery, and blood vessel of patients with severely injured trauma. Furthermore, bedside ultrasound scanning demonstrated superb capabilities in quantitatively displaying hemodynamics and outcomes of MBTs of patients with severely injured trauma.
Collapse
Affiliation(s)
- Lei Song
- Department of Intensive Care Unit, The Affiliated Qingdao Hospital of Shandong First Medical University, Qingdao 266109, Shandong, China
| | - Jianguo Zhang
- Department of Intensive Care Unit, The Affiliated Qingdao Hospital of Shandong First Medical University, Qingdao 266109, Shandong, China
| | - Junliang Liu
- Department of Intensive Care Unit, The Affiliated Qingdao Hospital of Shandong First Medical University, Qingdao 266109, Shandong, China
| |
Collapse
|
11
|
Fu H, Rao J, Harb MS, Theodossiades S. Ultrasonic wireless power links for battery-free condition monitoring in metallic enclosures. ULTRASONICS 2021; 114:106395. [PMID: 33756220 DOI: 10.1016/j.ultras.2021.106395] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Revised: 01/10/2021] [Accepted: 02/09/2021] [Indexed: 06/12/2023]
Abstract
This paper presented a novel ultrasonic wireless power link (UWPL) to provide power supply for embedded condition monitoring of enclosed metallic structures, where recharging or replacing batteries can be problematic. Two piezoelectric transducers are adopted to establish the wireless power links, within which one transducer is used to generate ultrasonic waves and the other is to receive the transferred ultrasonic energy and to energize the associated embedded condition monitoring units. A power management solution is established to regulate the receiver output into a constant voltage suitable for sensing application. A theoretical model was established to understand the UWPL dynamics and to analyze the energy budget balance between the UWPL and the sensing power demands. A finite element model was built to validate the proposed idea. The UWPL was then experimentally implemented using two piezoelectric transducers and tested in aluminium plates with different thickness. A power management sub-system was developed and tested for sensing applications. An output power of 1.73 mW was obtained on a 1.5 kΩ resister with the input voltage of 15 V at 42.6 kHz through a 6 mm-thick aluminium plate. Sufficient power can be transferred over a large distance via metallic structures, showing the capability in implementing battery-free condition monitoring of enclosed metallic structures, such as petroleum pipelines, engines, and aluminium airframe.
Collapse
Affiliation(s)
- Hailing Fu
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, LE11 3TU, UK.
| | - Jing Rao
- Chair of Computational Modeling and Simulation, Technical University of Munich, Arcisstr. 21, 80333 Munich, Germany.
| | - Mohammad S Harb
- Laboratory of Smart Structures and Structural Integrity, Department of Mechanical Engineering, American University of Beirut, Beirut, Lebanon.
| | - Stephanos Theodossiades
- Wolfson School of Mechanical, Electrical and Manufacturing Engineering, Loughborough University, LE11 3TU, UK.
| |
Collapse
|
12
|
Hwang BY, Mampre D, Ahmed AK, Suk I, Anderson WS, Manbachi A, Theodore N. Ultrasound in Traumatic Spinal Cord Injury: A Wide-Open Field. Neurosurgery 2021; 89:372-382. [PMID: 34098572 DOI: 10.1093/neuros/nyab177] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 03/19/2021] [Indexed: 02/02/2023] Open
Abstract
Traumatic spinal cord injury (SCI) is a common and devastating condition. In the absence of effective validated therapies, there is an urgent need for novel methods to achieve injury stabilization, regeneration, and functional restoration in SCI patients. Ultrasound is a versatile platform technology that can provide a foundation for viable diagnostic and therapeutic interventions in SCI. In particular, real-time perfusion and inflammatory biomarker monitoring, focal pharmaceutical delivery, and neuromodulation are capabilities that can be harnessed to advance our knowledge of SCI pathophysiology and to develop novel management and treatment options. Our review suggests that studies that evaluate the benefits and risks of ultrasound in SCI are severely lacking and our understanding of the technology's potential impact remains poorly understood. Although the complex anatomy and physiology of the spine and the spinal cord remain significant challenges, continued technological advances will help the field overcome the current barriers and bring ultrasound to the forefront of SCI research and development.
Collapse
Affiliation(s)
- Brian Y Hwang
- Division of Functional Neurosurgery, Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - David Mampre
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - A Karim Ahmed
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Ian Suk
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - William S Anderson
- Division of Functional Neurosurgery, Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.,Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Amir Manbachi
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Nicholas Theodore
- Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
13
|
Bhave G, Chen JC, Singer A, Sharma A, Robinson JT. Distributed sensor and actuator networks for closed-loop bioelectronic medicine. MATERIALS TODAY (KIDLINGTON, ENGLAND) 2021; 46:125-135. [PMID: 34366697 PMCID: PMC8336425 DOI: 10.1016/j.mattod.2020.12.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Designing implantable bioelectronic systems that continuously monitor physiological functions and simultaneously provide personalized therapeutic solutions for patients remains a persistent challenge across many applications ranging from neural systems to bioelectronic organs. Closed-loop systems typically consist of three functional blocks, namely, sensors, signal processors and actuators. An effective system, that can provide the necessary therapeutics, tailored to individual physiological factors requires a distributed network of sensors and actuators. While significant progress has been made, closed-loop systems still face many challenges before they can truly be considered as long-term solutions for many diseases. In this review, we consider three important criteria where materials play a critical role to enable implantable closed-loop systems: Specificity, Biocompatibility and Connectivity. We look at the progress made in each of these fields with respect to a specific application and outline the challenges in creating bioelectronic technologies for the future.
Collapse
|
14
|
Molino BZ, Fukuda J, Molino PJ, Wallace GG. Redox Polymers for Tissue Engineering. FRONTIERS IN MEDICAL TECHNOLOGY 2021; 3:669763. [PMID: 35047925 PMCID: PMC8757887 DOI: 10.3389/fmedt.2021.669763] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 04/22/2021] [Indexed: 01/23/2023] Open
Abstract
This review will focus on the targeted design, synthesis and application of redox polymers for use in regenerative medicine and tissue engineering. We define redox polymers to encompass a variety of polymeric materials, from the multifunctional conjugated conducting polymers to graphene and its derivatives, and have been adopted for use in the engineering of several types of stimulus responsive tissues. We will review the fundamental properties of organic conducting polymers (OCPs) and graphene, and how their properties are being tailored to enhance material - biological interfacing. We will highlight the recent development of high-resolution 3D fabrication processes suitable for biomaterials, and how the fabrication of intricate scaffolds at biologically relevant scales is providing exciting opportunities for the application of redox polymers for both in-vitro and in-vivo tissue engineering. We will discuss the application of OCPs in the controlled delivery of bioactive compounds, and the electrical and mechanical stimulation of cells to drive behaviour and processes towards the generation of specific functional tissue. We will highlight the relatively recent advances in the use of graphene and the exploitation of its physicochemical and electrical properties in tissue engineering. Finally, we will look forward at the future of organic conductors in tissue engineering applications, and where the combination of materials development and fabrication processes will next unite to provide future breakthroughs.
Collapse
Affiliation(s)
- Binbin Z. Molino
- Faculty of Engineering, Yokohama National University, Yokohama, Japan
- Kanagawa Institute of Industrial Science and Technology, Kawasaki, Japan
| | - Junji Fukuda
- Faculty of Engineering, Yokohama National University, Yokohama, Japan
- Kanagawa Institute of Industrial Science and Technology, Kawasaki, Japan
| | - Paul J. Molino
- Australian Research Council (ARC) Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW, Australia
| | - Gordon G. Wallace
- Australian Research Council (ARC) Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, University of Wollongong, Wollongong, NSW, Australia
| |
Collapse
|
15
|
MiniVStimA: A miniaturized easy to use implantable electrical stimulator for small laboratory animals. PLoS One 2020; 15:e0241638. [PMID: 33125415 PMCID: PMC7598460 DOI: 10.1371/journal.pone.0241638] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 10/16/2020] [Indexed: 01/17/2023] Open
Abstract
According to PubMed, roughly 10% of the annually added publications are describing findings from the small animal model (mice and rats), including investigations in the field of muscle physiology and training. A subset of this research requires neural stimulation with flexible adjustments of stimulation parameters, highlighting the need for reliable implantable electrical stimulators, small enough (~1 cm3), that even mice can tolerate them without impairing their movement. The MiniVStimA is a battery-powered implant for nerve stimulation with an outer diameter of 15 mm and an encapsulated volume of 1.2 cm3 in its smallest variation. It can be pre-programmed according to the experimental protocol and controlled after implantation with a magnet. It delivers constant current charge-balanced monophasic rectangular pulses up to 2 mA and 1 ms phase width (1 kΩ load). The circuitry is optimized for small volume and energy efficiency. Due to the variation of the internal oscillator (31 kHz ± 10%), calibration measures must be implemented during the manufacturing process, which can reduce the deviation of the frequency related parameters down to ± 1%. The expected lifetime of the smaller (larger) version is 100 (480) days for stimulation with 7 Hz all day and 10 (48) days for stimulation with 100 Hz. Devices with complex stimulation patterns for nerve stimulation have been successfully used in two in-vivo studies, lasting up to nine weeks. The implant worked fully self-contained while the animal stayed in its familiar environment. External components are not required during the entire time.
Collapse
|
16
|
Sun T, Wright J, Datta-Chaudhuri T. Ultrasound powered piezoelectric neurostimulation devices: a commentary. Bioelectron Med 2020; 6:16. [PMID: 32832580 PMCID: PMC7422591 DOI: 10.1186/s42234-020-00052-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 07/13/2020] [Indexed: 11/23/2022] Open
Abstract
Conventional neurostimulation systems for preclinical research can be bulky and invasive due to the need for batteries or wired interfaces. Emerging as a new neural interface technique, ultrasound-powered piezoelectric neural stimulators work by converting ultrasound energy to electrical charge for neural stimulation. In addition to the benefits of wireless powering and miniaturization leading to less traumatic surgery, piezoelectric neural stimulators can also exhibit prolonged operational lifetimes for a long-term stable neural interface, and show promise for clinical translation. As one of first steps to demonstrate the value of ultrasound-powered piezoelectric neural interface, Li et al. developed a piezoelectric stimulator to activate spinal cord neural circuits for locomotion restoration in a rat model with spinal cord injury (SCI) and compared its efficacy with conventional electrical stimulation (ES). From the point of view of materials science, neural engineering and microelectronics, we provide our commentary on the article, highlighting its importance and discussing the issues that remain to be addressed in future studies in the emerging field of ultrasound powered piezoelectric neurostimulation devices.
Collapse
Affiliation(s)
- Tao Sun
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Manhasset, NY USA
| | - Jason Wright
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Manhasset, NY USA
| | - Timir Datta-Chaudhuri
- Institute of Bioelectronic Medicine, The Feinstein Institutes for Medical Research, Manhasset, NY USA.,Zucker School of Medicine at Hofstra/Northwell, Hempstead, NY USA
| |
Collapse
|
17
|
Jiang D, Shi B, Ouyang H, Fan Y, Wang ZL, Li Z. Emerging Implantable Energy Harvesters and Self-Powered Implantable Medical Electronics. ACS NANO 2020; 14:6436-6448. [PMID: 32459086 DOI: 10.1021/acsnano.9b08268] [Citation(s) in RCA: 97] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
Implantable energy harvesters (IEHs) are the crucial component for self-powered devices. By harvesting energy from organisms such as heartbeat, respiration, and chemical energy from the redox reaction of glucose, IEHs are utilized as the power source of implantable medical electronics. In this review, we summarize the IEHs and self-powered implantable medical electronics (SIMEs). The typical IEHs are nanogenerators, biofuel cells, electromagnetic generators, and transcutaneous energy harvesting devices that are based on ultrasonic or optical energy. A benefit from these technologies of energy harvesting in vivo, SIMEs emerged, including cardiac pacemakers, nerve/muscle stimulators, and physiological sensors. We provide perspectives on the challenges and potential solutions associated with IEHs and SIMEs. Beyond the energy issue, we highlight the implanted devices that show the therapeutic function in vivo.
Collapse
Affiliation(s)
- Dongjie Jiang
- CAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 100083, China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Bojing Shi
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Han Ouyang
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Yubo Fan
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing 100083, China
| | - Zhong Lin Wang
- CAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 100083, China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, United States
| | - Zhou Li
- CAS Center for Excellence in Nanoscience, Beijing Key Laboratory of Micro-nano Energy and Sensor, Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 100083, China
- School of Nanoscience and Technology, University of Chinese Academy of Sciences, Beijing 100049, China
- Center on Nanoenergy Research, School of Physical Science and Technology, Guangxi University, Nanning 530004, China
| |
Collapse
|
18
|
Li S, Alam M, Ahmed RU, Zhong H, Wang XY, Ng S, Zheng YP. Ultrasound-driven piezoelectric current activates spinal cord neurocircuits and restores locomotion in rats with spinal cord injury. Bioelectron Med 2020; 6:13. [PMID: 32514413 PMCID: PMC7268413 DOI: 10.1186/s42234-020-00048-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Accepted: 04/16/2020] [Indexed: 01/19/2023] Open
Abstract
Background Neuromodulation via electrical stimulation (ES) is a common technique to treat numerous brain and spinal cord related neurological conditions. In the present study, we examined the efficacy of piezoelectric stimulation (pES) by a custom miniature piezostimulator to activate the spinal cord neurocircuit in comparison with conventional epidural ES in rats. Methods Stimulation electrodes were implanted on L2 and S1 spinal cord and were connected to a head-plug for ES, and a piezostimulator for pES. EMG electrodes were implanted into hindlimb muscles. To generate piezoelectric current, an ultrasound beam was delivered by an external ultrasound probe. Motor evoked potentials (MEPs) were recorded during the piezoelectric stimulation and compared with the signals generated by the ES. Results Our results suggest that ultrasound intensity as low as 0.1 mW/cm2 could induce MEPs in the hindlimbs. No significant difference was found either in MEPs or in muscle recruitments for ES and pES. Similar to ES, pES induced by 22.5 mW/cm2 ultrasound restored locomotion in paralyzed rats with complete thoracic cord injury. Locomotion EMG signals indicated that pES works same as ES. Conclusion We propose piezoelectric stimulation as a new avenue of neuromodulation with features overtaking conventional electrical stimulation to serve future bioelectronic medicine. Video abstract.
Collapse
Affiliation(s)
- Shuai Li
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| | - Monzurul Alam
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| | - Rakib Uddin Ahmed
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| | - Hui Zhong
- Department of Integrative Biology and Physiology, University of California, Los Angeles, USA
| | - Xiao-Yun Wang
- Guangdong Work Injury Rehabilitation Center, Guangzhou, China
| | - Serena Ng
- Community Rehabilitation Service Support Centre, Hospital Authority, Hong Kong, China
| | - Yong-Ping Zheng
- Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, China
| |
Collapse
|