1
|
Fan K, Cai Y, Shen E, Wang Y, Yuan J, Tao C, Liu X. Elevation Resolution Enhancement Oriented 3D Ultrasound Imaging. ULTRASONIC IMAGING 2024:1617346241259049. [PMID: 38903053 DOI: 10.1177/01617346241259049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
Three-dimensional (3D) ultrasound imaging can be accomplished by reconstructing a sequence of two-dimensional (2D) ultrasound images. However, 2D ultrasound images usually suffer from low resolution in the elevation direction, thereby impacting the accuracy of 3D reconstructed results. The lateral resolution of 2D ultrasound is known to significantly exceed the elevation resolution. By combining scanning sequences acquired from orthogonal directions, the effects of poor elevation resolution can be mitigated through a composite reconstructing process. Moreover, capturing ultrasound images from multiple perspectives necessitates a precise probe positioning method with a wide angle of coverage. Optical tracking is popularly used for probe positioning for its high accuracy and environment-robustness. In this paper, a novel large-angle accurate optical positioning method is used for enhancing resolution in 3D ultrasound imaging through orthogonal-view scanning and composite reconstruction. Experiments on two phantoms proved that our method could significantly improve reconstruction accuracy in the elevation direction of the probe compared with single-angle parallel scanning. The results indicate that our method holds the potential to improve current 3D ultrasound imaging techniques.
Collapse
Affiliation(s)
- Kai Fan
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Yunye Cai
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Enxiang Shen
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Yuxin Wang
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Jie Yuan
- School of Electronic Science and Engineering, Nanjing University, Nanjing, China
| | - Chao Tao
- School of Physics, Nanjing University, Nanjing, China
| | - Xiaojun Liu
- School of Physics, Nanjing University, Nanjing, China
| |
Collapse
|
2
|
Giovannelli AC, Köthe A, Safai S, Meer D, Zhang Y, Weber DC, Lomax AJ, Fattori G. Exploring beamline momentum acceptance for tracking respiratory variability in lung cancer proton therapy: a simulation study. Phys Med Biol 2023; 68:195013. [PMID: 37652055 DOI: 10.1088/1361-6560/acf5c4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Accepted: 08/31/2023] [Indexed: 09/02/2023]
Abstract
Objective. Investigating the aspects of proton beam delivery to track organ motion with pencil beam scanning therapy. Considering current systems as a reference, specify requirements for next-generation units aiming at real-time image-guided treatments.Approach. Proton treatments for six non-small cell lung cancer (NSCLC) patients were simulated using repeated 4DCTs to model respiratory motion variability. Energy corrections required for this treatment site were evaluated for different approaches to tumour tracking, focusing on the potential for energy adjustment within beamline momentum acceptance (dp/p). A respiration-synchronised tracking, taking into account realistic machine delivery limits, was compared to ideal tracking scenarios, in which unconstrained energy corrections are possible. Rescanning and the use of multiple fields to mitigate residual interplay effects and dose degradation have also been investigated.Main results. Energy correction requirements increased with motion amplitudes, for all patients and tracking scenarios. Higher dose degradation was found for larger motion amplitudes, rescanning has beneficial effects and helped to improve dosimetry metrics for the investigated limited dp/pof 1.2% (realistic) and 2.4%. The median differences between ideal and respiratory-synchronised tracking show minimal discrepancies, 1% and 5% respectively for dose coverage (CTV V95) and homogeneity (D5-D95). Multiple-field planning improves D5-D95 up to 50% in the most extreme cases while it does not show a significant effect on V95.Significance. This work shows the potential of implementing tumour tracking in current proton therapy units and outlines design requirements for future developments. Energy regulation within momentum acceptance was investigated to tracking tumour motion with respiratory-synchronisation, achieving results in line with the performance of ideal tracking scenarios. ±5% Δp/p would allow to compensate for all range offsets in our NSCLC patient cohort, including breathing variability. However, the realistic momentum of 1.2% dp/prepresentative of existing medical units limitations, has been shown to preserve plan quality.
Collapse
Affiliation(s)
- Anna Chiara Giovannelli
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
- Department of Physics, ETH Zürich, 8092 Zürich, Switzerland
| | - Andreas Köthe
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
- Department of Physics, ETH Zürich, 8092 Zürich, Switzerland
| | - Sairos Safai
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - David Meer
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Ye Zhang
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Damien Charles Weber
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
- Department of Radiation Oncology, University Hospital of Zürich, 8091 Zürich, Switzerland
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern, Switzerland
| | - Antony John Lomax
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
- Department of Physics, ETH Zürich, 8092 Zürich, Switzerland
| | - Giovanni Fattori
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| |
Collapse
|
3
|
Belikhin M, Pryanichnikov A, Balakin V, Shemyakov A, Zhogolev P, Chernyaev A. High-speed low-noise optical respiratory monitoring for spot scanning proton therapy. Phys Med 2023; 112:102612. [PMID: 37329740 DOI: 10.1016/j.ejmp.2023.102612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 04/24/2023] [Accepted: 05/30/2023] [Indexed: 06/19/2023] Open
Abstract
PURPOSE To investigate a novel optical markerless respiratory sensor for surface guided spot scanning proton therapy and to measure its main technical characteristics. METHODS The main characteristics of the respiratory sensor including sensitivity, linearity, noise, signal-to-noise, and time delay were measured using a dynamic phantom and electrical measuring equipment on a laboratory stand. The respiratory signals of free breathing and deep-inspiration breath-hold patterns were acquired for various distances with a volunteer. A comparative analysis of this sensor with existing commercially available and experimental respiratory monitoring systems was carried out based on several criteria including principle of operation, patient contact, application to proton therapy, distance range, accuracy (noise, signal-to-noise ratio), and time delay (sampling rate). RESULTS The sensor provides optical respiratory monitoring of the chest surface over a distance range of 0.4-1.2 m with the RMS noise of 0.03-0.60 mm, SNR of 40-15 dB (for motion with peak-to-peak of 10 mm), and time delay of 1.2 ± 0.2 ms. CONCLUSIONS The investigated optical respiratory sensor was found to be appropriate to use in surface guided spot scanning proton therapy. This sensor combined with a fast respiratory signal processing algorithm may provide accurate beam control and a fast response in patients' irregular breathing movements. A careful study of correlation between the respiratory signal and 4DCT data of tumor position will be required before clinical implementation.
Collapse
Affiliation(s)
- Mikhail Belikhin
- JSC Protom., Protvino 142281, Russian Federation; Lomonosov Moscow State University, Moscow 119992, Russian Federation.
| | - Alexander Pryanichnikov
- Division of Biomedical Physics in Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg 69120, Germany.
| | | | | | | | | |
Collapse
|
4
|
Hamaide V, Souris K, Dasnoy D, Glineur F, Macq B. Real-time image-guided treatment of mobile tumors in proton therapy by a library of treatment plans: a simulation study. Med Phys 2023; 50:465-479. [PMID: 36345808 DOI: 10.1002/mp.16084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 09/08/2022] [Accepted: 10/20/2022] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To improve target coverage and reduce the dose in the surrounding organs-at-risks (OARs), we developed an image-guided treatment method based on a precomputed library of treatment plans controlled and delivered in real-time. METHODS A library of treatment plans is constructed by optimizing a plan for each breathing phase of a four dimensional computed tomography (4DCT). Treatments are delivered by simulation on a continuous sequence of synthetic computed tomographies (CTs) generated from real magnetic resonance imaging (MRI) sequences. During treatment, the plans for which the tumor are at a close distance to the current tumor position are selected to deliver their spots. The study is conducted on five liver cases. RESULTS We tested our approach under imperfect knowledge of the tumor positions with a 2 mm distance error. On average, compared to a 4D robustly optimized treatment plan, our approach led to a dose homogeneity increase of 5% (defined as 1 - D 5 - D 95 prescription $1-\frac{D_5-D_{95}}{\text{prescription}}$ ) in the target and a mean liver dose decrease of 23%. The treatment time was roughly increased by a factor of 2 but remained below 4 min on average. CONCLUSIONS Our image-guided treatment framework outperforms state-of-the-art 4D-robust plans for all patients in this study on both target coverage and OARs sparing, with an acceptable increase in treatment time under the current accuracy of the tumor tracking technology.
Collapse
Affiliation(s)
| | | | - Damien Dasnoy
- ICTEAM Institute, UCLouvain, Louvain-la-Neuve, Belgium
| | | | - Benoît Macq
- ICTEAM Institute, UCLouvain, Louvain-la-Neuve, Belgium
| |
Collapse
|
5
|
Li G. Advances and potential of optical surface imaging in radiotherapy. Phys Med Biol 2022; 67:10.1088/1361-6560/ac838f. [PMID: 35868290 PMCID: PMC10958463 DOI: 10.1088/1361-6560/ac838f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Accepted: 07/22/2022] [Indexed: 11/12/2022]
Abstract
This article reviews the recent advancements and future potential of optical surface imaging (OSI) in clinical applications as a four-dimensional (4D) imaging modality for surface-guided radiotherapy (SGRT), including OSI systems, clinical SGRT applications, and OSI-based clinical research. The OSI is a non-ionizing radiation imaging modality, offering real-time 3D surface imaging with a large field of view (FOV), suitable for in-room interactive patient setup, and real-time motion monitoring at any couch rotation during radiotherapy. So far, most clinical SGRT applications have focused on treating superficial breast cancer or deep-seated brain cancer in rigid anatomy, because the skin surface can serve as tumor surrogates in these two clinical scenarios, and the procedures for breast treatments in free-breathing (FB) or at deep-inspiration breath-hold (DIBH), and for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) are well developed. When using the skin surface as a body-position surrogate, SGRT promises to replace the traditional tattoo/laser-based setup. However, this requires new SGRT procedures for all anatomical sites and new workflows from treatment simulation to delivery. SGRT studies in other anatomical sites have shown slightly higher accuracy and better performance than a tattoo/laser-based setup. In addition, radiographical image-guided radiotherapy (IGRT) is still necessary, especially for stereotactic body radiotherapy (SBRT). To go beyond the external body surface and infer an internal tumor motion, recent studies have shown the clinical potential of OSI-based spirometry to measure dynamic tidal volume as a tumor motion surrogate, and Cherenkov surface imaging to guide and assess treatment delivery. As OSI provides complete datasets of body position, deformation, and motion, it offers an opportunity to replace fiducial-based optical tracking systems. After all, SGRT has great potential for further clinical applications. In this review, OSI technology, applications, and potential are discussed since its first introduction to radiotherapy in 2005, including technical characterization, different commercial systems, and major clinical applications, including conventional SGRT on top of tattoo/laser-based alignment and new SGRT techniques attempting to replace tattoo/laser-based setup. The clinical research for OSI-based tumor tracking is reviewed, including OSI-based spirometry and OSI-guided tumor tracking models. Ongoing clinical research has created more SGRT opportunities for clinical applications beyond the current scope.
Collapse
Affiliation(s)
- Guang Li
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10065, United States of America
| |
Collapse
|
6
|
Pakela JM, Knopf A, Dong L, Rucinski A, Zou W. Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future. Front Oncol 2022; 12:806153. [PMID: 35356213 PMCID: PMC8959592 DOI: 10.3389/fonc.2022.806153] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 02/04/2022] [Indexed: 12/14/2022] Open
Abstract
The major aim of radiation therapy is to provide curative or palliative treatment to cancerous malignancies while minimizing damage to healthy tissues. Charged particle radiotherapy utilizing carbon ions or protons is uniquely suited for this task due to its ability to achieve highly conformal dose distributions around the tumor volume. For these treatment modalities, uncertainties in the localization of patient anatomy due to inter- and intra-fractional motion present a heightened risk of undesired dose delivery. A diverse range of mitigation strategies have been developed and clinically implemented in various disease sites to monitor and correct for patient motion, but much work remains. This review provides an overview of current clinical practices for inter and intra-fractional motion management in charged particle therapy, including motion control, current imaging and motion tracking modalities, as well as treatment planning and delivery techniques. We also cover progress to date on emerging technologies including particle-based radiography imaging, novel treatment delivery methods such as tumor tracking and FLASH, and artificial intelligence and discuss their potential impact towards improving or increasing the challenge of motion mitigation in charged particle therapy.
Collapse
Affiliation(s)
- Julia M Pakela
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, United States
| | - Antje Knopf
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, Netherlands.,Department I of Internal Medicine, Center for Integrated Oncology Cologne, University Hospital of Cologne, Cologne, Germany
| | - Lei Dong
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, United States
| | - Antoni Rucinski
- Institute of Nuclear Physics, Polish Academy of Sciences, Krakow, Poland
| | - Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, United States
| |
Collapse
|
7
|
Fattori G, Lomax AJ, Weber DC, Safai S. Technical assessment of the NDI Polaris Vega optical tracking system. Radiat Oncol 2021; 16:87. [PMID: 33980248 PMCID: PMC8114517 DOI: 10.1186/s13014-021-01804-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 04/07/2021] [Indexed: 12/02/2022] Open
Abstract
The Polaris product line from Northern Digital Inc. is well known for accurate optical tracking measurements in research and medical environments. The Spectra position sensor, to date often found in image guided radiotherapy suites, has however reached its end-of-life, being replaced by the new Vega model. The performance in static and dynamic measurements of this new device has been assessed in controlled laboratory conditions, against the strict requirements for system integration in radiation therapy. The system accuracy has improved with respect to the Spectra in both static (0.045 mm RMSE) and dynamic (0.09 mm IQR, < 20 cm/s) tracking and brings marginal improvement in the measurement latency (14.2 ± 1.8 ms). The system performance was further confirmed under clinical settings with the report of early results from periodic QA tests within specifications. Based on our tests, the Polaris Vega meets the quality standards of radiotherapy applications and can be safely used for monitoring respiratory breathing motion or verifying patient positioning.
Collapse
Affiliation(s)
- Giovanni Fattori
- Center for Proton Therapy, Paul Scherrer Institute, Forschungsstrasse 111, 5232, Villigen, Switzerland
| | - Antony John Lomax
- Center for Proton Therapy, Paul Scherrer Institute, Forschungsstrasse 111, 5232, Villigen, Switzerland. .,Department of Physics, ETH Zurich, 8092, Zurich, Switzerland.
| | - Damien Charles Weber
- Center for Proton Therapy, Paul Scherrer Institute, Forschungsstrasse 111, 5232, Villigen, Switzerland.,Department of Radiation Oncology, University Hospital Zurich, 8091, Zurich, Switzerland.,Department of Radiation Oncology, University Hospital Bern, 3000, Bern, Switzerland
| | - Sairos Safai
- Center for Proton Therapy, Paul Scherrer Institute, Forschungsstrasse 111, 5232, Villigen, Switzerland
| |
Collapse
|
8
|
Lis M, Newhauser W, Donetti M, Wolf M, Steinsberger T, Paz A, Durante M, Graeff C. A Modular System for Treating Moving Anatomical Targets With Scanned Ion Beams at Multiple Facilities: Pre-Clinical Testing for Quality and Safety of Beam Delivery. Front Oncol 2021; 11:620388. [PMID: 33816251 PMCID: PMC8018284 DOI: 10.3389/fonc.2021.620388] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Accepted: 01/25/2021] [Indexed: 12/26/2022] Open
Abstract
Background Quality management and safety are integral to modern radiotherapy. New radiotherapy technologies require new consensus guidelines on quality and safety. Established analysis strategies, such as the failure modes and effects analysis (FMEA) and incident learning systems have been developed as tools to assess the safety of several types of radiation therapies. An extensive literature documents the widespread application of risk analysis methods to photon radiation therapy. Relatively little attention has been paid to performing risk analyses of nascent radiation therapy systems to treat moving tumors with scanned heavy ion beams. The purpose of this study was to apply a comprehensive safety analysis strategy to a motion-synchronized dose delivery system (M-DDS) for ion therapy. Methods We applied a risk analysis method to new treatment planning and treatment delivery processes with scanned heavy ion beams. The processes utilize a prototype, modular dose delivery system, currently undergoing preclinical testing, that provides new capabilities for treating moving anatomy. Each step in the treatment process was listed in a process map, potential errors for each step were identified and scored using the risk probability number in an FMEA, and the possible causes of each error were described in a fault tree analysis. Solutions were identified to mitigate the risk of these errors, including permanent corrective actions, periodic quality assurance (QA) tests, and patient specific QA (PSQA) tests. Each solution was tested experimentally. Results The analysis revealed 58 potential errors that could compromise beam delivery quality or safety. Each of the 14 binary (pass-or-fail) tests passed. Each of the nine QA and four PSQA tests were within anticipated clinical specifications. The modular M-DDS was modified accordingly, and was found to function at two centers. Conclusion We have applied a comprehensive risk analysis strategy to the M-DDS and shown that it is a clinically viable motion mitigation strategy. The described strategy can be utilized at any ion therapy center that operates with the modular M-DDS. The approach can also be adapted for use at other facilities and can be combined with existing safety analysis systems.
Collapse
Affiliation(s)
- Michelle Lis
- Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany.,Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, United States
| | - Wayne Newhauser
- Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, United States.,Department of Radiation Physics, Mary Bird Perkins Cancer Center, Baton Rouge, LA, United States
| | - Marco Donetti
- Research and Development Department, Centro Nazionale di Androterapia Oncologia, Pavia, Italy
| | - Moritz Wolf
- Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
| | - Timo Steinsberger
- Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany.,Institute of Condensed Matter Physics, Technical University of Darmstadt, Darmstadt, Germany
| | - Athena Paz
- Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
| | - Marco Durante
- Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany.,Institute of Condensed Matter Physics, Technical University of Darmstadt, Darmstadt, Germany
| | - Christian Graeff
- Biophysics, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany
| |
Collapse
|
9
|
Czerska K, Emert F, Kopec R, Langen K, McClelland JR, Meijers A, Miyamoto N, Riboldi M, Shimizu S, Terunuma T, Zou W, Knopf A, Rucinski A. Clinical practice vs. state-of-the-art research and future visions: Report on the 4D treatment planning workshop for particle therapy - Edition 2018 and 2019. Phys Med 2021; 82:54-63. [PMID: 33588228 DOI: 10.1016/j.ejmp.2020.12.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 12/09/2020] [Accepted: 12/16/2020] [Indexed: 12/18/2022] Open
Abstract
The 4D Treatment Planning Workshop for Particle Therapy, a workshop dedicated to the treatment of moving targets with scanned particle beams, started in 2009 and since then has been organized annually. The mission of the workshop is to create an informal ground for clinical medical physicists, medical physics researchers and medical doctors interested in the development of the 4D technology, protocols and their translation into clinical practice. The 10th and 11th editions of the workshop took place in Sapporo, Japan in 2018 and Krakow, Poland in 2019, respectively. This review report from the Sapporo and Krakow workshops is structured in two parts, according to the workshop programs. The first part comprises clinicians and physicists review of the status of 4D clinical implementations. Corresponding talks were given by speakers from five centers around the world: Maastro Clinic (The Netherlands), University Medical Center Groningen (The Netherlands), MD Anderson Cancer Center (United States), University of Pennsylvania (United States) and The Proton Beam Therapy Center of Hokkaido University Hospital (Japan). The second part is dedicated to novelties in 4D research, i.e. motion modelling, artificial intelligence and new technologies which are currently being investigated in the radiotherapy field.
Collapse
Affiliation(s)
- Katarzyna Czerska
- Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland.
| | - Frank Emert
- Center for Proton Therapy, Paul Scherrer Institute, Switzerland
| | - Renata Kopec
- Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland
| | - Katja Langen
- Department of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, GA, USA
| | - Jamie R McClelland
- Centre for Medical Image Computing, Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Arturs Meijers
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Naoki Miyamoto
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan; Faculty of Engineering, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Marco Riboldi
- Department of Medical Physics, Ludwig-Maximilians-Universität München, Germany
| | - Shinichi Shimizu
- Department of Medical Physics, Hokkaido University Hospital, Sapporo, Hokkaido, Japan; Department of Radiation Medical Science and Engineering, Faculty of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan
| | - Toshiyuki Terunuma
- Faculty of Medicine, University of Tsukuba, Japan; Proton Medical Research Center, University of Tsukuba Hospital, Japan
| | - Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Antje Knopf
- Department of Radiation Oncology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Antoni Rucinski
- Institute of Nuclear Physics Polish Academy of Sciences, PL-31342 Krakow, Poland
| |
Collapse
|
10
|
Fattori G, Hrbacek J, Regele H, Bula C, Mayor A, Danuser S, Oxley DC, Rechsteiner U, Grossmann M, Via R, Böhlen TT, Bolsi A, Walser M, Togno M, Colvill E, Lempen D, Weber DC, Lomax AJ, Safai S. Commissioning and quality assurance of a novel solution for respiratory-gated PBS proton therapy based on optical tracking of surface markers. Z Med Phys 2020; 32:52-62. [PMID: 32830006 PMCID: PMC9948868 DOI: 10.1016/j.zemedi.2020.07.001] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 06/01/2020] [Accepted: 07/10/2020] [Indexed: 12/15/2022]
Abstract
We present the commissioning and quality assurance of our clinical protocol for respiratory gating in pencil beam scanning proton therapy for cancer patients with moving targets. In a novel approach, optical tracking has been integrated in the therapy workflow and used to monitor respiratory motion from multiple surrogates, applied on the patients' chest. The gating system was tested under a variety of experimental conditions, specific to proton therapy, to evaluate reaction time and reproducibility of dose delivery control. The system proved to be precise in the application of beam gating and allowed the mitigation of dose distortions even for large (1.4cm) motion amplitudes, provided that adequate treatment windows were selected. The total delivered dose was not affected by the use of gating, with measured integral error within 0.15cGy. Analysing high-resolution images of proton transmission, we observed negligible discrepancies in the geometric location of the dose as a function of the treatment window, with gamma pass rate greater than 95% (2%/2mm) compared to stationary conditions. Similarly, pass rate for the latter metric at the 3%/3mm level was observed above 97% for clinical treatment fields, limiting residual movement to 3mm at end-exhale. These results were confirmed in realistic clinical conditions using an anthropomorphic breathing phantom, reporting a similarly high 3%/3mm pass rate, above 98% and 94%, for regular and irregular breathing, respectively. Finally, early results from periodic QA tests of the optical tracker have shown a reliable system, with small variance observed in static and dynamic measurements.
Collapse
Affiliation(s)
- Giovanni Fattori
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland.
| | - Jan Hrbacek
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Harald Regele
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Christian Bula
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Alexandre Mayor
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Stefan Danuser
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - David C. Oxley
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Urs Rechsteiner
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Martin Grossmann
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Riccardo Via
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Till T. Böhlen
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Alessandra Bolsi
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Marc Walser
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Michele Togno
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Emma Colvill
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Daniel Lempen
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| | - Damien C. Weber
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland,Department of Radiation Oncology, University Hospital Zurich, 8091 Zurich, Switzerland,Department of Radiation Oncology, University Hospital Bern, 3000 Bern, Switzerland
| | - Antony J. Lomax
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland,Department of Physics, ETH Zurich, 8092 Zurich, Switzerland
| | - Sairos Safai
- Center for Proton Therapy, Paul Scherrer Institute, 5232 Villigen, Switzerland
| |
Collapse
|
11
|
Freislederer P, Kügele M, Öllers M, Swinnen A, Sauer TO, Bert C, Giantsoudi D, Corradini S, Batista V. Recent advanced in Surface Guided Radiation Therapy. Radiat Oncol 2020; 15:187. [PMID: 32736570 PMCID: PMC7393906 DOI: 10.1186/s13014-020-01629-w] [Citation(s) in RCA: 66] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2020] [Accepted: 07/21/2020] [Indexed: 01/27/2023] Open
Abstract
The growing acceptance and recognition of Surface Guided Radiation Therapy (SGRT) as a promising imaging technique has supported its recent spread in a large number of radiation oncology facilities. Although this technology is not new, many aspects of it have only recently been exploited. This review focuses on the latest SGRT developments, both in the field of general clinical applications and special techniques.SGRT has a wide range of applications, including patient positioning with real-time feedback, patient monitoring throughout the treatment fraction, and motion management (as beam-gating in free-breathing or deep-inspiration breath-hold). Special radiotherapy modalities such as accelerated partial breast irradiation, particle radiotherapy, and pediatrics are the most recent SGRT developments.The fact that SGRT is nowadays used at various body sites has resulted in the need to adapt SGRT workflows to each body site. Current SGRT applications range from traditional breast irradiation, to thoracic, abdominal, or pelvic tumor sites, and include intracranial localizations.Following the latest SGRT applications and their specifications/requirements, a stricter quality assurance program needs to be ensured. Recent publications highlight the need to adapt quality assurance to the radiotherapy equipment type, SGRT technology, anatomic treatment sites, and clinical workflows, which results in a complex and extensive set of tests.Moreover, this review gives an outlook on the leading research trends. In particular, the potential to use deformable surfaces as motion surrogates, to use SGRT to detect anatomical variations along the treatment course, and to help in the establishment of personalized patient treatment (optimized margins and motion management strategies) are increasingly important research topics. SGRT is also emerging in the field of patient safety and integrates measures to reduce common radiotherapeutic risk events (e.g. facial and treatment accessories recognition).This review covers the latest clinical practices of SGRT and provides an outlook on potential applications of this imaging technique. It is intended to provide guidance for new users during the implementation, while triggering experienced users to further explore SGRT applications.
Collapse
Affiliation(s)
- P. Freislederer
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - M. Kügele
- Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Lund, Sweden
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, Lund, Sweden
| | - M. Öllers
- Maastricht Radiation Oncology (MAASTRO), Maastricht, the Netherlands
| | - A. Swinnen
- Maastricht Radiation Oncology (MAASTRO), Maastricht, the Netherlands
| | - T.-O. Sauer
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - C. Bert
- Department of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - D. Giantsoudi
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, USA
| | - S. Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - V. Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
- Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany
- National Center for Tumor diseases (NCT), Heidelberg, Germany
| |
Collapse
|
12
|
Sorriento A, Porfido MB, Mazzoleni S, Calvosa G, Tenucci M, Ciuti G, Dario P. Optical and Electromagnetic Tracking Systems for Biomedical Applications: A Critical Review on Potentialities and Limitations. IEEE Rev Biomed Eng 2019; 13:212-232. [PMID: 31484133 DOI: 10.1109/rbme.2019.2939091] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Optical and electromagnetic tracking systems represent the two main technologies integrated into commercially-available surgical navigators for computer-assisted image-guided surgery so far. Optical Tracking Systems (OTSs) work within the optical spectrum to track the position and orientation, i.e., pose of target surgical instruments. OTSs are characterized by high accuracy and robustness to environmental conditions. The main limitation of OTSs is the need of a direct line-of-sight between the optical markers and the camera sensor, rigidly fixed into the operating theatre. Electromagnetic Tracking Systems (EMTSs) use electromagnetic field generator to detect the pose of electromagnetic sensors. EMTSs do not require such a direct line-of-sight, however the presence of metal or ferromagnetic sources in the operating workspace can significantly affect the measurement accuracy. The aim of the proposed review is to provide a complete and detailed overview of optical and electromagnetic tracking systems, including working principles, source of error and validation protocols. Moreover, commercial and research-oriented solutions, as well as clinical applications, are described for both technologies. Finally, a critical comparative analysis of the state of the art which highlights the potentialities and the limitations of each tracking system for a medical use is provided.
Collapse
|
13
|
Bertholet J, Knopf A, Eiben B, McClelland J, Grimwood A, Harris E, Menten M, Poulsen P, Nguyen DT, Keall P, Oelfke U. Real-time intrafraction motion monitoring in external beam radiotherapy. Phys Med Biol 2019; 64:15TR01. [PMID: 31226704 PMCID: PMC7655120 DOI: 10.1088/1361-6560/ab2ba8] [Citation(s) in RCA: 111] [Impact Index Per Article: 22.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2019] [Revised: 05/10/2019] [Accepted: 06/21/2019] [Indexed: 12/25/2022]
Abstract
Radiotherapy (RT) aims to deliver a spatially conformal dose of radiation to tumours while maximizing the dose sparing to healthy tissues. However, the internal patient anatomy is constantly moving due to respiratory, cardiac, gastrointestinal and urinary activity. The long term goal of the RT community to 'see what we treat, as we treat' and to act on this information instantaneously has resulted in rapid technological innovation. Specialized treatment machines, such as robotic or gimbal-steered linear accelerators (linac) with in-room imaging suites, have been developed specifically for real-time treatment adaptation. Additional equipment, such as stereoscopic kilovoltage (kV) imaging, ultrasound transducers and electromagnetic transponders, has been developed for intrafraction motion monitoring on conventional linacs. Magnetic resonance imaging (MRI) has been integrated with cobalt treatment units and more recently with linacs. In addition to hardware innovation, software development has played a substantial role in the development of motion monitoring methods based on respiratory motion surrogates and planar kV or Megavoltage (MV) imaging that is available on standard equipped linacs. In this paper, we review and compare the different intrafraction motion monitoring methods proposed in the literature and demonstrated in real-time on clinical data as well as their possible future developments. We then discuss general considerations on validation and quality assurance for clinical implementation. Besides photon RT, particle therapy is increasingly used to treat moving targets. However, transferring motion monitoring technologies from linacs to particle beam lines presents substantial challenges. Lessons learned from the implementation of real-time intrafraction monitoring for photon RT will be used as a basis to discuss the implementation of these methods for particle RT.
Collapse
Affiliation(s)
- Jenny Bertholet
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
- Author to whom any correspondence should be
addressed
| | - Antje Knopf
- Department of Radiation Oncology,
University Medical Center
Groningen, University of Groningen, The
Netherlands
| | - Björn Eiben
- Department of Medical Physics and Biomedical
Engineering, Centre for Medical Image Computing, University College London, London,
United Kingdom
| | - Jamie McClelland
- Department of Medical Physics and Biomedical
Engineering, Centre for Medical Image Computing, University College London, London,
United Kingdom
| | - Alexander Grimwood
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| | - Emma Harris
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| | - Martin Menten
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| | - Per Poulsen
- Department of Oncology, Aarhus University Hospital, Aarhus,
Denmark
| | - Doan Trang Nguyen
- ACRF Image X Institute, University of Sydney, Sydney,
Australia
- School of Biomedical Engineering,
University of Technology
Sydney, Sydney, Australia
| | - Paul Keall
- ACRF Image X Institute, University of Sydney, Sydney,
Australia
| | - Uwe Oelfke
- Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS
Foundation Trust, London, United
Kingdom
| |
Collapse
|
14
|
The dosimetric effect of residual breath-hold motion in pencil beam scanned proton therapy – An experimental study. Radiother Oncol 2019; 134:135-142. [DOI: 10.1016/j.radonc.2019.01.033] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2017] [Revised: 01/25/2019] [Accepted: 01/27/2019] [Indexed: 12/25/2022]
|
15
|
Fattori G, Klimpki G, Hrbacek J, Zhang Y, Krieger M, Placidi L, Psoroulas S, Weber DC, Lomax AJ, Safai S. The dependence of interplay effects on the field scan direction in PBS proton therapy. Phys Med Biol 2019; 64:095005. [PMID: 30893664 DOI: 10.1088/1361-6560/ab1150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The literature is controversial about the scan direction dependency of interplay effects in pencil beam scanning (PBS) treatment of moving targets. A directional effect is supported by many simulation studies, whereas the experimental data are mostly limited to simple geometries, not reflecting realistically clinical treatment plans. We have compared increasingly complex treatment fields, from a homogeneous single energy layer to a more modulated lung plan, under identical experimental settings, seeking evidence for differences in motion mitigation due to the selection of primary scanning direction. In total, 120 experimental samples were taken, combining two primary scan directions and three rescanning regimes with different motion scenarios. 4D dose distributions were measured in water with a moving ionisation chamber array and compared to those of a stationary delivery using 2D gamma analysis. Each plan has been verified twice for the same rescanning regime and motion scenario, changing the meandering direction in between to scan perpendicularly to, or along, the target motion. Additionally, machine log files of the lung plan, together with 4DCT data, were used to calculate the dose distribution that such deliveries would have produced in the patient. The primary meandering direction has a clear influence on measured dose distributions when considering a single energy layer. Introducing spot weight modulation and multiple energy layers however, makes the dynamic of interplay more complex and difficult to predict. Overall, gamma (3%/3 mm) differences between scanning along or orthogonal to the target motion follow a normal distribution [Formula: see text] when considering multiple motion scenarios and rescanning regimes. Nevertheless, data spread [Formula: see text] is significant enough such that, for individual experiments and set-ups, a dependency may be observed even if this is not a general result. Patient reconstructed doses follow the same trend, the two primary scan directions producing statistically insignificant differences in dose distributions in terms of conformity or homogeneity. Except for extremely simplified cases of mono-energetic and homogeneous treatment fields, the interplay effect has been found to be only marginally influenced by the choice of the primary scanning direction.
Collapse
Affiliation(s)
- G Fattori
- Paul Scherrer Institute (PSI), Center for Proton Therapy, 5232 Villigen PSI, Switzerland. The author to whom correspondence may be addressed
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Landry G, Hua CH. Current state and future applications of radiological image guidance for particle therapy. Med Phys 2018; 45:e1086-e1095. [PMID: 30421805 DOI: 10.1002/mp.12744] [Citation(s) in RCA: 72] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 10/25/2017] [Accepted: 11/30/2017] [Indexed: 12/27/2022] Open
Abstract
In this review paper, we first give a short overview of radiological image guidance in photon radiotherapy, placing emphasis on the fact that linac based radiotherapy has outpaced particle therapy in the adoption of volumetric image guidance. While cone beam computed tomography (CBCT) has been an established technique in linac treatment rooms for almost two decades, the widespread adoption of volumetric image guidance in particle therapy, whether by means of CBCT or in-room CT imaging, is recent. This lag may be attributable to the bespoke nature and lower number of particle therapy installations, as well as the differences in geometry between those installations and linac treatment rooms. In addition, for particle therapy the so called shift invariance of the dose distribution rarely applies. An overview of the different volumetric image guidance solutions found at modern particle therapy facilities is provided, covering gantry, nozzle, C-arm, and couch-mounted CBCT as well different in-room CT configurations. A summary of the use of in-room volumetric imaging data beyond anatomy-based positioning is also presented as well as the necessary corrections to CBCT images for accurate water equivalent thickness calculation. Finally, the use of non-ionizing imaging modalities is discussed.
Collapse
Affiliation(s)
- Guillaume Landry
- Faculty of Physics, Department of Medical Physics, Ludwig-Maximilians-Universität München (LMU Munich), 85748, Garching b. München, Germany
| | - Chia-Ho Hua
- Department of Radiation Oncology, St. Jude Children's Research Hospital, Memphis, TN, 38105, USA
| |
Collapse
|
17
|
Klimpki G, Zhang Y, Fattori G, Psoroulas S, Weber DC, Lomax A, Meer D. The impact of pencil beam scanning techniques on the effectiveness and efficiency of rescanning moving targets. ACTA ACUST UNITED AC 2018; 63:145006. [DOI: 10.1088/1361-6560/aacd27] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
18
|
Abstract
Proton therapy is a promising but challenging treatment modality for the management of lung cancer. The technical challenges are due to respiratory motion, low dose tolerance of adjacent normal tissue and tissue density heterogeneity. Different imaging modalities are applied at various steps of lung proton therapy to provide information on target definition, target motion, proton range, patient setup and treatment outcome assessment. Imaging data is used to guide treatment design, treatment delivery, and treatment adaptation to ensure the treatment goal is achieved. This review article will summarize and compare various imaging techniques that can be used in every step of lung proton therapy to address these challenges.
Collapse
Affiliation(s)
- Miao Zhang
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Wei Zou
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| | - Boon-Keng Kevin Teo
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
19
|
Krieger M, Klimpki G, Fattori G, Hrbacek J, Oxley D, Safai S, Weber DC, Lomax AJ, Zhang Y. Experimental validation of a deforming grid 4D dose calculation for PBS proton therapy. ACTA ACUST UNITED AC 2018; 63:055005. [DOI: 10.1088/1361-6560/aaad1e] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
20
|
A statistical comparison of motion mitigation performances and robustness of various pencil beam scanned proton systems for liver tumour treatments. Radiother Oncol 2018; 128:182-188. [PMID: 29459153 DOI: 10.1016/j.radonc.2018.01.019] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Revised: 01/30/2018] [Accepted: 01/31/2018] [Indexed: 12/13/2022]
Abstract
BACKGROUND AND PURPOSE Different scanned proton therapy systems provide different scanning scenarios, directly changing the temporal interference between sequential beam delivery and tumour motion. We aim here to quantify the interplay effects and compare motion mitigation performance among different PBS scanning systems. MATERIALS AND METHODS Using 6 4DCT(MRI) datasets of liver tumours with irregular motions greater than 10 mm, 4D treatments with single- and double-field plans, and assuming various doses and motion mitigation approaches, were simulated for 8 PBS scenarios including spot or raster scanning, layered or volumetric rescanning, gating, constant or varying beam current and cyclotron or synchrotron beam sources. The resulting 4D plans were compared using the homogeneity index (D5-D95 in CTV) and treatment time. RESULTS Independent of scanning scenario and field dose, neither gating nor rescanning alone could mitigate motion effects completely. Re-gating (rescanning with gating) however was found to be similarly effective for all scanning scenarios, most field doses and both rescan modes, with the difference being mainly in the treatment efficiency. The advantage of cyclotron-based systems together with layer-by-layer beam current variation was demonstrated by the nearly constant treatment time as a function of increased field dose. CONCLUSION Independently of PBS scanning dynamics, re-gating is sufficient to achieve acceptable 4D plan quality close to those of the static references.
Collapse
|