Svärd SJ, Hindorf C, Nilsson JN. Count-rate management in 131I SPECT/CT calibration. EJNMMI Phys 2025; 12:8. [PMID: 39864022 PMCID: PMC11769881 DOI: 10.1186/s40658-025-00718-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2024] [Accepted: 01/13/2025] [Indexed: 01/27/2025] Open
Abstract
BACKGROUND System calibration is essential for accurate SPECT/CT dosimetry. However, count losses due to dead time and pulse pileup may cause calibration errors, in particular for 131I, where high count rates may be encountered. Calibration at low count rates should also be avoided to minimise detrimental effects from e.g. background counts and statistical fluctuations. This paper aims to present experimental data illustrating count-rate dependencies and to propose practical routines to mitigate errors in the 131I calibration procedure without needing advanced analysis tools. RESULTS The sensitivities of two General Electric (GE) Discovery 670 Pro systems were assessed using two Jaszczak phantom geometries. SPECT/CT data were collected over two months, starting with an initial 131I content of > 2 GBq, decaying to approximately 20 MBq. This allowed for a detailed analysis of count losses due to dead time and pulse pileup. From the sensitivity analysis, it was shown that robust calibration was obtained for 131I phantom activities ranging between 250 and 1500 MBq. CONCLUSIONS The results show that adequate corrections for dead-time and pulse-pileup counting losses are essential for accurate calibration. It is argued that loss corrections should be based on total spectrum count rates in projections and not only on the 364.5 keV energy window data. The measurement campaigns presented in this paper, using basic tools and equipment, may serve as a model for establishing routines for count-loss corrections as well as for system calibration and regular control of system sensitivity. The data suggest that analysis of source and count concentration in a homogeneous Jaszczak phantom offers robust calibration, whereas analysis of source strength and counts in a delineated phantom insert offers a practical and robust method for regular quality control.
Collapse
Affiliation(s)
- Staffan Jacobsson Svärd
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden
| | - Cecilia Hindorf
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Joachim N Nilsson
- Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Solna, Sweden.
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
| |
Collapse
|
2
|
Danieli R, Mileva M, Marin G, Kristanto P, Delbart W, Vanderlinden B, Wimana Z, Hendlisz A, Levillain H, Reynaert N, Flamen P, Karfis I. Evolution of dosimetric parameters through PRRT and potential impact on clinical practice: data from the prospective phase II LUMEN study. EJNMMI Res 2024; 14:110. [PMID: 39557730 PMCID: PMC11574229 DOI: 10.1186/s13550-024-01163-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Accepted: 10/16/2024] [Indexed: 11/20/2024] Open
Abstract
BACKGROUND Peptide receptor radionuclide therapy (PRRT) with [177Lu]Lu-DOTA-TATE has emerged as a promising treatment for gastroenteropancreatic neuroendocrine tumours (GEP-NETs). Its treatment protocol is currently standardised for all patients, resulting in different patient outcomes. This study investigates the variability of tumours and organs-at-risk (kidneys and red marrow) dosimetric parameters across treatment cycles in patients with pancreatic and intestinal NETs. Data from 37 patients enrolled in a prospective phase II study (LuMEn) were analysed. Treatment consisted of four cycles of [177Lu]Lu-DOTA-TATE administered 8-12 weeks apart. Three-time-point SPECT/CT imaging was performed after each treatment cycle, and dosimetry of tumours and organs-at-risk (kidneys and red marrow) was conducted following the medical internal radiation dose formalism. Coefficients of variation (CoV) assessed the variability of absorbed doses, activity concentrations on day 1, and effective half-lives. Linear mixed effect models (SAS software) were used to investigate the evolution of the dosimetric parameters over cycles, discerning between different primary NET types and grades of tumours. RESULTS There is an important variability in absorbed doses and activity concentrations among patients, particularly in tumours (CoV: ~50%). Tumour absorbed doses and activity concentrations decreased over treatment cycles in pancreatic NETs, although at a limited rate (~-13%/cycle). An opposite trend was observed for the kidneys ( ~ + 8%/cycle). Effective half-lives remained relatively constant across cycles for both organs-at-risk and tumours. The primary NET type significantly influenced effective half-lives in tumours, shorter in pancreatic NETs than intestinal NETs (77 h vs. 107 h, p < 0.0001). No significant effect of the grade was observed on either of the variables investigated. CONCLUSIONS Our study revealed considerable variations in tumour absorbed doses among patients with NETs treated with a standardized protocol. These findings confirm the need for personalized dosimetry approaches in PRRT, considering patient and tumour characteristics. TRIAL REGISTRATION EudraCT Number: 2012-003666-41. CLINICALTRIALS gov identifier: NCT01842165. Registered 25 April 2013, https://clinicaltrials.gov/ct2/show/NCT01842165 .
Collapse
Affiliation(s)
- Rachele Danieli
- Medical Physics Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory (ULB836), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Magdalena Mileva
- Nuclear Medicine Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
| | - Gwennaëlle Marin
- Medical Physics Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory (ULB836), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Paulus Kristanto
- Data Center, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
| | - Wendy Delbart
- Nuclear Medicine Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
| | - Bruno Vanderlinden
- Medical Physics Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory (ULB836), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Zéna Wimana
- Nuclear Medicine Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
- Radiopharmacy Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
| | - Alain Hendlisz
- Medical Oncology Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
| | - Hugo Levillain
- Medical Physics Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory (ULB836), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Nick Reynaert
- Medical Physics Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory (ULB836), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Patrick Flamen
- Nuclear Medicine Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium
| | - Ioannis Karfis
- Nuclear Medicine Department, ENETS Centre of Excellence, Institut Jules Bordet, Université Libre de Bruxelles (ULB), Hôpital Universitaire de Bruxelles (H.U.B), Brussels, Belgium.
| |
Collapse
|
3
|
Ramonaheng K, Qebetu M, Ndlovu H, Swanepoel C, Smith L, Mdanda S, Mdlophane A, Sathekge M. Activity quantification and dosimetry in radiopharmaceutical therapy with reference to 177Lutetium. FRONTIERS IN NUCLEAR MEDICINE (LAUSANNE, SWITZERLAND) 2024; 4:1355912. [PMID: 39355215 PMCID: PMC11440950 DOI: 10.3389/fnume.2024.1355912] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/12/2024] [Indexed: 10/03/2024]
Abstract
Radiopharmaceutical therapy has been widely adopted owing primarily to the development of novel radiopharmaceuticals. To fully utilize the potential of these RPTs in the era of precision medicine, therapy must be optimized to the patient's tumor characteristics. The vastly disparate dosimetry methodologies need to be harmonized as the first step towards this. Multiple factors play a crucial role in the shift from empirical activity administration to patient-specific dosimetry-based administrations from RPT. Factors such as variable responses seen in patients with presumably similar clinical characteristics underscore the need to standardize and validate dosimetry calculations. These efforts combined with ongoing initiatives to streamline the dosimetry process facilitate the implementation of radiomolecular precision oncology. However, various challenges hinder the widespread adoption of personalized dosimetry-based activity administration, particularly when compared to the more convenient and resource-efficient approach of empiric activity administration. This review outlines the fundamental principles, procedures, and methodologies related to image activity quantification and dosimetry with a specific focus on 177Lutetium-based radiopharmaceuticals.
Collapse
Affiliation(s)
- Keamogetswe Ramonaheng
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
- Department of Nuclear Medicine, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Milani Qebetu
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
| | - Honest Ndlovu
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
- Department of Nuclear Medicine, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Cecile Swanepoel
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
| | - Liani Smith
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
| | - Sipho Mdanda
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
- Department of Nuclear Medicine, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Amanda Mdlophane
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
- Department of Nuclear Medicine, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| | - Mike Sathekge
- Department of Medical Physics and Radiobiology, Nuclear Medicine Research, Infrastructure (NuMeRI) NPC, Pretoria, South Africa
- Department of Nuclear Medicine, Steve Biko Academic Hospital, Pretoria, South Africa
- Department of Nuclear Medicine, Faculty of Health Sciences, University of Pretoria, Pretoria, South Africa
| |
Collapse
|
4
|
Nuttens V, Schramm G, D'Asseler Y, Koole M. Comparison of a 3D CZT and conventional SPECT/CT system for quantitative Lu-177 SPECT imaging. EJNMMI Phys 2024; 11:29. [PMID: 38499797 PMCID: PMC10948674 DOI: 10.1186/s40658-024-00627-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 02/27/2024] [Indexed: 03/20/2024] Open
Abstract
PURPOSE Next-generation SPECT/CT systems with CdZnTe (CZT) digital detectors in a ring-like setup are emerging to perform quantitative Lu-177 SPECT imaging in clinical routine. It is essential to assess how the shorter acquisition time might affect the image quality and uncertainty on the mean absorbed dose of the tumors and organs at risk compared to a conventional system. METHODS A NEMA Image Quality phantom was scanned with a 3D CZT SPECT/CT system (Veriton, by Spectrum Dynamics) using 6 min per bed position and with a conventional SPECT/CT system (Symbia T16, by Siemens) using 16 min per bed position. The sphere-to-background ratio was 12:1 and the background activity concentration ranged from 0.52 to 0.06 MBq/mL. A clinical reconstruction protocol for dosimetry purposes was determined for both systems by maximizing the sphere-to-background ratio while keeping the coefficient of variation of the background as low as possible. The corresponding image resolution was determined by the matching filter method and used for a dose uncertainty assessment of both systems following an established uncertainty model.. RESULTS The optimized iterative reconstruction protocol included scatter and attenuation correction for both systems and detector response modeling for the Siemens system. For the 3D CZT system, 6 iterations and 8 subsets were combined with a Gaussian post-filter of 3 mm Full Width Half Maximum (FWHM) for post-smoothing. For the conventional system, 16 iterations and 16 subsets were applied with a Gaussian post-smoothing filter of 1 mm FWHM. For these protocols, the sphere-to-background ratio was 18.5% closer to the true ratio for the conventional system compared to the 3D CZT system when considering the four largest spheres. Meanwhile, the background coefficient of variation was very similar for both systems. These protocols resulted in SPECT image resolution of 14.8 mm and 13.6 mm for the 3D CZT and conventional system respectively. Based on these resolution estimates, a 50% dose uncertainty corresponded to a lesion volume of 28 mL for the conventional system and a lesion volume of 33 mL for the 3D CZT system. CONCLUSIONS An optimized reconstruction protocol for a Veriton system with 6 min of acquisition time per bed position resulted in slightly higher dose uncertainties than a conventional Symbia system using 16 min of acquisition time per bed position. Therefore, a 3D CZT SPECT/CT allows to significantly reduce the acquisition times with only a very limited impact on dose uncertainties such that quantitative Lu-177 SPECT/CT imaging becomes much more accessible for treatment concurrent dosimetry. Nevertheless, the uncertainty of SPECT-based dose estimates remains high.
Collapse
Affiliation(s)
- Victor Nuttens
- Nuclear Medicine, OLV Aalst, Aalst, Belgium.
- Nuclear Medicine and Molecular Imaging, KU Leuven, Leuven, Belgium.
| | - Georg Schramm
- Nuclear Medicine and Molecular Imaging, KU Leuven, Leuven, Belgium
| | - Yves D'Asseler
- Nuclear Medicine, Ghent University Hospital, Ghent, Belgium
- Diagnostic Sciences, Ghent University, Ghent, Belgium
| | - Michel Koole
- Nuclear Medicine and Molecular Imaging, KU Leuven, Leuven, Belgium
| |
Collapse
|
5
|
Danieli R, Stella M, Leube J, Tran-Gia J, Marin C, Uribe CF, Vanderlinden B, Reynaert N, Flamen P, Levillain H. Quantitative 177Lu SPECT/CT imaging for personalized dosimetry using a ring-shaped CZT-based camera. EJNMMI Phys 2023; 10:64. [PMID: 37853247 PMCID: PMC10584798 DOI: 10.1186/s40658-023-00586-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/12/2023] [Indexed: 10/20/2023] Open
Abstract
BACKGROUND Dosimetry after radiopharmaceutical therapy with 177Lu (177Lu-RPT) relies on quantitative SPECT/CT imaging, for which suitable reconstruction protocols are required. In this study, we characterized for the first time the quantitative performance of a ring-shaped CZT-based camera using two different reconstruction algorithms: an ordered subset expectation maximization (OSEM) and a block sequential regularized expectation maximization (BSREM) combined with noise reduction regularization. This study lays the foundations for the definition of a reconstruction protocol enabling accurate dosimetry for patients treated with 177Lu-RPT. METHODS A series of 177Lu-filled phantoms were acquired on a StarGuide™ (GE HealthCare), with energy and scatter windows centred at 208 (± 6%) keV and 185 (± 5%) keV, respectively. Images were reconstructed with the manufacturer implementations of OSEM (GE-OSEM) and BSREM (Q.Clear) algorithms, and various combinations of iterations and subsets. Additionally, the manufacturer-recommended Q.Clear-based reconstruction protocol was evaluated. Quantification accuracy, measured as the difference between the SPECT-based and the radionuclide calibrator-based activity, and noise were evaluated in a large cylinder. Recovery coefficients (RCs) and spatial resolution were assessed in a NEMA IEC phantom with sphere inserts. The reconstruction protocols considered suitable for clinical applications were tested on a cohort of patients treated with [177Lu]Lu-PSMA-I&T. RESULTS The accuracy of the activity from the cylinder, although affected by septal penetration, was < 10% for all reconstructions. Both algorithms featured improved spatial resolution and higher RCs with increasing updates at the cost of noise build-up, but Q.Clear outperformed GE-OSEM in reducing noise accumulation. When the reconstruction parameters were carefully selected, similar values for noise (~0.15), spatial resolution (~1 cm) and RCs were found, irrespective of the reconstruction algorithm. Analogue results were found in patients. CONCLUSIONS Accurate activity quantification is possible when imaging 177Lu with StarGuide™. However, the impact of septal penetration requires further investigations. GE-OSEM is a valid alternative to the recommended Q.Clear reconstruction algorithm, featuring comparable performances assessed on phantoms and patients.
Collapse
Affiliation(s)
- Rachele Danieli
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium.
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium.
| | - Martina Stella
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
- GE HealthCare, Diegem, Belgium
| | - Julian Leube
- Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany
| | - Johannes Tran-Gia
- Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany
| | - Clementine Marin
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | | | - Bruno Vanderlinden
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Nick Reynaert
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Patrick Flamen
- Department of Nuclear Medicine, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
| | - Hugo Levillain
- Department of Medical Physics, Institut Jules Bordet, Hôpital Universitaire de Bruxelles (H.U.B), Université Libre de Bruxelles (ULB), Brussels, Belgium
- Radiophysics and MRI Physics Laboratory, Université Libre de Bruxelles (ULB), Brussels, Belgium
| |
Collapse
|
6
|
Ardenfors O, Nilsson JN, Thor D, Hindorf C. Simplified dosimetry for kidneys and tumors in 177Lu-labeled peptide receptor radionuclide therapy. EJNMMI Phys 2022; 9:44. [PMID: 35723797 PMCID: PMC9209556 DOI: 10.1186/s40658-022-00473-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Accepted: 06/09/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate if satisfactory post-therapeutic image-based dosimetry can be achieved for Lu-177-DOTATATE treatments using a reduced number of image acquisitions to improve patient comfort and reduce economical costs. Methods 39 patients who underwent 147 treatment cycles of Lu-177-DOTATATE for neuroendocrine tumors were included in the study. A total of 291 and 284 absorbed doses were calculated to kidneys and tumors, respectively. Single-point dosimetry was performed using one SPECT/CT image acquired at 1 d or 7 d post-treatment using a fixed effective half-life (Teff) or using a patient-specific Teff determined for the initial cycle. Also, dose-per-activity values, (D/A)1, were determined from the first cycle and used to calculate doses for subsequent cycles. All absorbed doses were evaluated against “true” doses calculated using both the 1 d and 7 d images. The relation between tumor grade and absorbed doses was also investigated. All dosimetry was performed on SPECT images. Results Absorbed doses to kidneys were most accurate when single-point dosimetry was performed using 1 d images with median ratios in relation to “true” doses in total dose of 1.00 (IQR: 0.97–1.03) when using fixed Teff and 1.01 (IQR: 0.98–1.04) when using Teff from the initial cycle. Calculations based on the 7 d image were most accurate for tumors with corresponding ratios in total absorbed dose of 0.98 (IQR: 0.96–1.00) and 1.00 (IQR: 0.99–1.01) when using a fixed Teff or Teff from the first cycle, respectively. The (D/A)1 approach performed worse, as 2 of 77 total absorbed doses to the kidneys deviated with > 30%, and tumor-absorbed doses were increasingly overestimated with every cycle. Absorbed doses, Teff and 1 d uptake were higher for G1 tumors than G2 tumors. Conclusion Dosimetry can be performed with satisfactory accuracy when using single SPECT/CT images acquired at 1 d for kidneys or at 7 d for tumors.
Collapse
Affiliation(s)
- Oscar Ardenfors
- Department of Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76, Stockholm, Sweden. .,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden.
| | - Joachim N Nilsson
- Department of Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76, Stockholm, Sweden.,Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| | - Daniel Thor
- Department of Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76, Stockholm, Sweden.,Department of Oncology-Pathology, Karolinska Institutet, Stockholm, Sweden
| | - Cecilia Hindorf
- Department of Radiation Physics and Nuclear Medicine, Karolinska University Hospital, 171 76, Stockholm, Sweden.,Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
7
|
Xu L, Meng Q, Yao X, Yang R, Zhang P, Li R, Wang F. Dosimetry of 177Lu-DOTATOC first circle treatment in patients with advanced metastatic neuroendocrine tumors: A pilot study in China. Appl Radiat Isot 2021; 179:109975. [PMID: 34741954 DOI: 10.1016/j.apradiso.2021.109975] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 08/19/2021] [Accepted: 09/14/2021] [Indexed: 12/20/2022]
Abstract
First cycle dosimetry calculation of 177Lu-DOTATOC (single activity:1.59-3.49 GBq) was carried out in eight patients with advanced neuroendocrine tumors (NETs) who underwent whole-body planar (0.5, 24, 48, 72 h) and SPECT/CT scans (24 h). Focal uptake of 177Lu-DOTATOC was found in primary and metastatic tumors. Organs with the highest absorbed doses per injected activity were tumors (1.293 ± 0.862 mGy/MBq) and spleen (0.461 ± 0.408 mGy/MBq), while low absorbed doses were observed in kidneys (0.384 ± 0.112 mGy/MBq) and bone marrow (0.0297 ± 0.0123 mGy/MBq). 177Lu-DOTATOC is safe, well-tolerated and appropriate in Chinese NETs patients for PRRT.
Collapse
Affiliation(s)
- Lei Xu
- Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210006, China
| | - Qingle Meng
- Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210006, China
| | - Xiaochen Yao
- Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210006, China
| | - Rui Yang
- Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210006, China
| | - Pengjun Zhang
- Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210006, China
| | - Rushuai Li
- Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210006, China
| | - Feng Wang
- Department of Nuclear Medicine, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210006, China.
| |
Collapse
|
8
|
Könik A, O'Donoghue JA, Wahl RL, Graham MM, Van den Abbeele AD. Theranostics: The Role of Quantitative Nuclear Medicine Imaging. Semin Radiat Oncol 2021; 31:28-36. [PMID: 33246633 DOI: 10.1016/j.semradonc.2020.07.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Theranostics is a precision medicine discipline that integrates diagnostic nuclear medicine imaging with radionuclide therapy in a manner that provides both a tumor phenotype and personalized therapy to patients with cancer using radiopharmaceuticals aimed at the same target-specific biological pathway or receptor. The aim of quantitative nuclear medicine imaging is to plan the alpha or beta-emitting therapy based on an accurate 3-dimensional representation of the in-vivo distribution of radioactivity concentration within the tumor and normal organs/tissues in a noninvasive manner. In general, imaging may be either based on positron emission tomography (PET) or single photon emission computed tomography (SPECT) invariably in combination with X-ray CT (PET/CT; SPECT/CT) or, to a much lesser extent, MRI. PET and SPECT differ in terms of the radionuclides and physical processes that give rise to the emission of high energy photons, as well as the sets of technologies involved in their detection. Using a variety of standardized quantitative parameters, system calibration, patient preparation, imaging acquisition and reconstruction protocols, and image analysis protocols, an accurate quantification of the tracer distribution can be obtained, which helps prescribe the therapeutic dose for each patient.
Collapse
Affiliation(s)
- Arda Könik
- Department of Imaging, Dana-Farber Cancer Institute, Boston, MA.
| | - Joseph A O'Donoghue
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Richard L Wahl
- Department of Radiology, Mallinckrodt Institute of Radiology, Washington University in St Louis School of Medicine, St. Louis, MO
| | - Michael M Graham
- Past Director of Nuclear Medicine, Roy J and Lucille A. Carver College of Medicine, University of Iowa, Iowa City, IA
| | - Annick D Van den Abbeele
- Department of Imaging, Dana-Farber Cancer Institute, Boston, MA; Division of Cancer Imaging, Mass General Brigham, Boston, MA; Dana-Farber Cancer Institute and Mass General Brigham, Boston, MA; Center for Biomedical Imaging in Oncology, Dana-Farber Cancer Institute, Boston, MA; Tumor Imaging Metrics Core, Dana-Farber/Harvard Cancer Center, Boston, MA
| |
Collapse
|
9
|
Finocchiaro D, Gear JI, Fioroni F, Flux GD, Murray I, Castellani G, Versari A, Iori M, Grassi E. Uncertainty analysis of tumour absorbed dose calculations in molecular radiotherapy. EJNMMI Phys 2020; 7:63. [PMID: 33044651 PMCID: PMC7550507 DOI: 10.1186/s40658-020-00328-5] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2020] [Accepted: 09/16/2020] [Indexed: 01/25/2023] Open
Abstract
BACKGROUND Internal dosimetry evaluation consists of a multi-step process ranging from imaging acquisition to absorbed dose calculations. Assessment of uncertainty is complicated and, for that reason, it is commonly ignored in clinical routine. However, it is essential for adequate interpretation of the results. Recently, the EANM published a practical guidance on uncertainty analysis for molecular radiotherapy based on the application of the law of propagation of uncertainty. In this study, we investigated the overall uncertainty on a sample of a patient following the EANM guidelines. The aim of this study was to provide an indication of the typical uncertainties that may be expected from performing dosimetry, to determine parameters that have the greatest effect on the accuracy of calculations and to consider the potential improvements that could be made if these effects were reduced. RESULTS Absorbed doses and the relative uncertainties were calculated for a sample of 49 patients and a total of 154 tumours. A wide range of relative absorbed dose uncertainty values was observed (14-102%). Uncertainties associated with each quantity along the absorbed dose calculation chain (i.e. volume, recovery coefficient, calibration factor, activity, time-activity curve fitting, time-integrated activity and absorbed dose) were estimated. An equation was derived to describe the relationship between the uncertainty in the absorbed dose and the volume. The largest source of error was the VOI delineation. By postulating different values of FWHM, the impact of the imaging system spatial resolution on the uncertainties was investigated. DISCUSSION To the best of our knowledge, this is the first analysis of uncertainty in molecular radiotherapy based on a cohort of clinical cases. Wide inter-lesion variability of absorbed dose uncertainty was observed. Hence, a proper assessment of the uncertainties associated with the calculations should be considered as a basic scientific standard. A model for a quick estimate of uncertainty without implementing the entire error propagation schema, which may be useful in clinical practice, was presented. Ameliorating spatial resolution may be in future the key factor for accurate absorbed dose assessment.
Collapse
Affiliation(s)
- Domenico Finocchiaro
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy.,Department of Physics and Astronomy, University of Bologna, Bologna, Italy
| | - Jonathan I Gear
- The Royal Marsden NHS Foundation Trust & Institute of Cancer Research, Downs Road, Sutton, SM2 5PT, UK
| | - Federica Fioroni
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy.
| | - Glenn D Flux
- The Royal Marsden NHS Foundation Trust & Institute of Cancer Research, Downs Road, Sutton, SM2 5PT, UK
| | - Iain Murray
- The Royal Marsden NHS Foundation Trust & Institute of Cancer Research, Downs Road, Sutton, SM2 5PT, UK
| | - Gastone Castellani
- Department of Physics and Astronomy, University of Bologna, Bologna, Italy
| | - Annibale Versari
- Nuclear Medicine Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy
| | - Mauro Iori
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy
| | - Elisa Grassi
- Medical Physics Unit, Azienda Unità Sanitaria Locale di Reggio Emilia - IRCCS, Reggio Emilia, Italy
| |
Collapse
|
10
|
Mora-Ramirez E, Santoro L, Cassol E, Ocampo-Ramos JC, Clayton N, Kayal G, Chouaf S, Trauchessec D, Pouget JP, Kotzki PO, Deshayes E, Bardiès M. Comparison of commercial dosimetric software platforms in patients treated with 177 Lu-DOTATATE for peptide receptor radionuclide therapy. Med Phys 2020; 47:4602-4615. [PMID: 32632928 PMCID: PMC7589428 DOI: 10.1002/mp.14375] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 06/21/2020] [Accepted: 06/22/2020] [Indexed: 12/17/2022] Open
Abstract
Purpose The aim of this study was to quantitatively compare five commercial dosimetric software platforms based on the analysis of clinical datasets of patients who benefited from peptide receptor radionuclide therapy (PRRT) with 177Lu‐DOTATATE (LUTATHERA®). Methods The dosimetric analysis was performed on two patients during two cycles of PRRT with 177Lu. Single photon emission computed tomography/computed tomography images were acquired at 4, 24, 72, and 192 h post injection. Reconstructed images were generated using Dosimetry Toolkit® (DTK) from Xeleris™ and HybridRecon‐Oncology version_1.3_Dicom (HROD) from HERMES. Reconstructed images using DTK were analyzed using the same software to calculate time‐integrated activity coefficients (TIAC), and mean absorbed doses were estimated using OLINDA/EXM V1.0 with mass correction. Reconstructed images from HROD were uploaded into PLANET® OncoDose from DOSIsoft, STRATOS from Phillips, Hybrid Dosimetry Module™ from HERMES, and SurePlan™ MRT from MIM. Organ masses, TIACs, and mean absorbed doses were calculated from each application using their recommendations. Results The majority of organ mass estimates varied by <9.5% between all platforms. The highest variability for TIAC results between platforms was seen for the kidneys (28.2%) for the two patients and the two treatment cycles. Relative standard deviations in mean absorbed doses were slightly higher compared with those observed for TIAC, but remained of the same order of magnitude between all platforms. Conclusions When applying a similar processing approach, results obtained were of the same order of magnitude regardless of the platforms used. However, the comparison of the performances of currently available platforms is still difficult as they do not all address the same parts of the dosimetric analysis workflow. In addition, the way in which data are handled in each part of the chain from data acquisition to absorbed doses may be different, which complicates the comparison exercise. Therefore, the dissemination of commercial solutions for absorbed dose calculation calls for the development of tools and standards allowing for the comparison of the performances between dosimetric software platforms.
Collapse
Affiliation(s)
- Erick Mora-Ramirez
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,Escuela de Física - CICANUM, Universidad de Costa Rica, San José, 11501-2060, Costa Rica
| | - Lore Santoro
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Emmanuelle Cassol
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,Département de Médecine Nucléaire, Hôpitaux Toulouse, Toulouse, F-31059, France.,Faculté de Médecine Rangueil, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Juan C Ocampo-Ramos
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Naomi Clayton
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| | - Gunjan Kayal
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France.,SCK CEN, Belgian Nuclear Research Centre, Boeretang 200, Mol, BE-2400, Belgium
| | - Soufiane Chouaf
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Dorian Trauchessec
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France
| | - Jean-Pierre Pouget
- Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Pierre-Olivier Kotzki
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Emmanuel Deshayes
- Département de Médecine Nucléaire, Institut Régional du Cancer de Montpellier, Montpellier, F-34298, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), Inserm U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, F-34298, France
| | - Manuel Bardiès
- Centre de Recherches en Cancérologie de Toulouse, UMR 1037, Toulouse, F-31037, France.,INSERM, UMR 1037, Université Toulouse III Paul Sabatier, Toulouse, F-31062, France
| |
Collapse
|
11
|
Desy A, Bouvet GF, Frezza A, Després P, Beauregard JM. Impact of dead time on quantitative 177Lu-SPECT (QSPECT) and kidney dosimetry during PRRT. EJNMMI Phys 2020; 7:32. [PMID: 32415492 PMCID: PMC7229114 DOI: 10.1186/s40658-020-00303-0] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 05/05/2020] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Dead time may affect the accuracy of quantitative SPECT (QPSECT), and thus of dosimetry. The aim of this study was to quantify the effect of dead time on 177Lu-QSPECT and renal dosimetry following peptide receptor radionuclide therapy (PRRT) of neuroendocrine tumours. METHODS QSPECT/CT was performed on days 1 and 3 during 564 personalized 177Lu-octreotate cycles in 166 patients. The dead-time data for each scanning time point was compiled. The impact of not correcting QSPECT for the dead time was assessed for the kidney dosimetry. This was also estimated for empiric PRRT by simulating in our cohort a regime of 7.4 GBq/cycle. RESULTS The probability to observe a larger dead time increased with the injected activity. A dead-time loss greater than 5% affected 14.4% and 5.7% of QSPECT scans performed at days 1 and 3, respectively. This resulted in renal absorbed dose estimates that would have been underestimated by more than 5% in 5.7% of cycles if no dead-time correction was applied, with a maximum underestimation of 22.1%. In the simulated empiric regime, this potential dose underestimation would have been limited to 6.2%. CONCLUSION Dead-time correction improves the accuracy of dosimetry in 177Lu radionuclide therapy and is warranted in personalized PRRT.
Collapse
Affiliation(s)
- Alessandro Desy
- Cancer Research Centre and Department of Radiology and Nuclear Medicine, Université Laval, Quebec City, Canada.,Department of Medical Imaging and Oncology Division of Research Centre, CHU de Québec-Université Laval, 11 côte du Palais, Quebec City, G1R 2J6, Canada
| | - Guillaume F Bouvet
- Cancer Research Centre and Department of Radiology and Nuclear Medicine, Université Laval, Quebec City, Canada.,Department of Medical Imaging and Oncology Division of Research Centre, CHU de Québec-Université Laval, 11 côte du Palais, Quebec City, G1R 2J6, Canada
| | - Andrea Frezza
- Cancer Research Centre and Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada
| | - Philippe Després
- Cancer Research Centre and Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada.,Department of Radiation Oncology and Oncology Division of Research Centre, CHU de Québec-Université Laval, 11 côte du Palais, Quebec City, QC, G1R 2J6, Canada
| | - Jean-Mathieu Beauregard
- Cancer Research Centre and Department of Radiology and Nuclear Medicine, Université Laval, Quebec City, Canada. .,Department of Medical Imaging and Oncology Division of Research Centre, CHU de Québec-Université Laval, 11 côte du Palais, Quebec City, G1R 2J6, Canada.
| |
Collapse
|
12
|
Frezza A, Desport C, Uribe C, Zhao W, Celler A, Després P, Beauregard JM. Comprehensive SPECT/CT system characterization and calibration for 177Lu quantitative SPECT (QSPECT) with dead-time correction. EJNMMI Phys 2020; 7:10. [PMID: 32060777 PMCID: PMC7021856 DOI: 10.1186/s40658-020-0275-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Accepted: 01/26/2020] [Indexed: 12/31/2022] Open
Abstract
Background Personalization of 177Lu-based radionuclide therapy requires implementation of dosimetry methods that are both accurate and practical enough for routine clinical use. Quantitative single-photon emission computed tomography/computed tomography (QSPECT/CT) is the preferred scanning modality to achieve this and necessitates characterizing the response of the camera, and calibrating it, over the full range of therapeutic activities and system capacity. Various methods to determine the camera calibration factor (CF) and the deadtime constant (τ) were investigated, with the aim to design a simple and robust protocol for quantitative 177Lu imaging. Methods The SPECT/CT camera was equipped with a medium energy collimator. Multiple phantoms were used to reproduce various attenuation conditions: rod sources in air or water-equivalent media, as well as a Jaszczak phantom with inserts. Planar and tomographic images of a wide range of activities were acquired, with multiple energy windows for scatter correction (double or triple energy window technique) as well as count rate monitoring over a large spectrum of energy. Dead time was modelled using the paralysable model. CF and τ were deduced by curve fitting either separately in two steps (CF determined first using a subset of low-activity acquisitions, then τ determined using the full range of activity) or at once (both CF and τ determined using the full range of activity). Total or segmented activity in the SPECT field of view was computed. Finally, these methods were compared in terms of accuracy to recover the known activity, in particular when planar-derived parameters were applied to the SPECT data. Results The SPECT camera was shown to operate as expected on a finite count rate range (up to ~ 350 kcps over the entire energy spectrum). CF and τ from planar (sources in air) and SPECT segmented Jaszczak data yielded a very good agreement (CF < 1% and τ < 3%). Determining CF and τ from a single curve fit made dead-time-corrected images less prone to overestimating recovered activity. Using triple-energy window scatter correction while acquiring one or more additional energy window(s) to enable wide-spectrum count rate monitoring (i.e. ranging 55–250 or 18–680 keV) yielded the most consistent results across the various geometries. The final, planar-derived calibration parameters for our system were a CF of 9.36 ± 0.01 cps/MBq and a τ of 0.550 ± 0.003 μs. Using the latter, the activity in a Jaszczak phantom could be quantified by QSPECT with an accuracy of 0.02 ± 1.10%. Conclusions Serial planar acquisitions of sources in air using an activity range covering the full operational capacity of the SPECT/CT system, with multiple energy windows for wide-spectrum count rate monitoring, and followed by simultaneous determination of CF and τ using a single equation derived from the paralysable model, constitutes a practical method to enable accurate dead-time-corrected QSPECT imaging in a post-177Lu radionuclide therapy setting.
Collapse
Affiliation(s)
- Andrea Frezza
- Cancer Research Center, Université Laval, Quebec City, QC, Canada.,Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada.,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada
| | - Corentin Desport
- Cancer Research Center, Université Laval, Quebec City, QC, Canada.,Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada.,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada
| | - Carlos Uribe
- Functional Imaging Department, BC Cancer, Vancouver, BC, Canada
| | - Wei Zhao
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, BC, Canada
| | - Anna Celler
- Medical Imaging Research Group, Department of Radiology, University of British Columbia, Vancouver, BC, Canada
| | - Philippe Després
- Cancer Research Center, Université Laval, Quebec City, QC, Canada.,Department of Physics, Engineering Physics and Optics, Université Laval, Quebec City, QC, Canada.,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada.,Department of Radiation Oncology, CHU de Québec - Université Laval, Quebec City, QC, Canada
| | - Jean-Mathieu Beauregard
- Cancer Research Center, Université Laval, Quebec City, QC, Canada. .,Oncology Division, CHU de Québec - Université Laval Research Center, Quebec City, QC, Canada. .,Department of Radiology and Nuclear Medicine, Université Laval, Quebec City, QC, Canada. .,Department of Medical Imaging, CHU de Québec - Université Laval, 11 côte du Palais, Quebec City, QC, G1R 2J6, Canada.
| |
Collapse
|
13
|
Abstract
The continuous development of SPECT over the past 50 years has led to improved image quality and increased diagnostic confidence. The most influential developments include the realization of hybrid SPECT/CT devices, as well as the implementation of attenuation correction and iterative image reconstruction techniques. These developments have led to a preference for SPECT/CT devices over SPECT-only systems and to the widespread adoption of the former, strengthening the role of SPECT/CT as the workhorse of Nuclear Medicine imaging. New trends in the ongoing development of SPECT/CT are diverse. For example, whole-body SPECT/CT images, consisting of acquisitions from multiple consecutive bed positions in the manner of PET/CT, are increasingly performed. Additionally, in recent years, some interesting approaches in detector technology have found their way into commercial products. For example, some SPECT cameras dedicated to specific organs employ semiconductor detectors made of cadmium telluride or cadmium zinc telluride, which have been shown to increase the obtainable image quality by offering a higher sensitivity and energy resolution. However, the advent of quantitative SPECT/CT which, like PET, can quantify the amount of tracer in terms of Bq/mL or as a standardized uptake value could be regarded as most important development. It is a major innovation that will lead to increased diagnostic accuracy and confidence, especially in longitudinal studies and in the monitoring of treatment response. The current work comprises two main aspects. At first, physical and technical fundamentals of SPECT image formation are described and necessary prerequisites of quantitative SPECT/CT are reviewed. Additionally, the typically achievable quantitative accuracy based on reports from the literature is given. Second, an extensive list of studies reporting on clinical applications of quantitative SPECT/CT is provided and reviewed.
Collapse
Affiliation(s)
- Philipp Ritt
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany.
| | - Torsten Kuwert
- Clinic of Nuclear Medicine, University Hospital Erlangen, Ulmenweg 18, 91054, Erlangen, Germany
| |
Collapse
|
14
|
Rinscheid A, Kletting P, Eiber M, Beer AJ, Glatting G. Technical Note: Optimal sampling schedules for kidney dosimetry based on the hybrid planar/SPECT method in 177 Lu-PSMA therapy. Med Phys 2019; 46:5861-5866. [PMID: 31587333 DOI: 10.1002/mp.13846] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2019] [Revised: 08/27/2019] [Accepted: 09/19/2019] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Accurate and precise renal dosimetry during 177 Lu-labeled prostate-specific membrane antigen (PSMA) radioligand therapy is crucial for therapy decisions. Sampling schedules for estimating the necessary time-integrated activity coefficients (TIACs) are not optimized and standardized for clinical practice. Therefore, a simulation study to determine optimal sampling schedules (OSSs) was performed on 13 virtual 177 Lu-PSMA I&T therapy patients. METHOD A total of 880 clinically feasible sampling schedules for planar imaging (three time points) were investigated. To simulate the hybrid planar/SPECT method, an additional quantitative SPECT/CT measurement following one planar image was considered. For each sampling schedule and patient, the activity values were generated separately. Measurement noise was modeled by drawing random numbers of log-normal distributions. The used fractional standard deviations (FSD) differed depending on the imaging modality. For activity values assigned to planar imaging, systematic noise between 25% and 75% of the total noise was simulated. After fitting with a mono-exponential function, the root-mean-squared errors of the deviations of the simulated TIACs from the ground truth for 1000 replications were used to determine the OSS. The uncertainties of the TIACs and renal dose coefficients were estimated. RESULTS For the hybrid planar/SPECT method, OSSs were determined to be (3-4, 72-76, 124-144) h post injection (p.i.) with the quantitative SPECT/CT scan shortly after the second measurement. The accuracy and precision of the determined TIACs were in the range of (-3.0 ± 6.2)% and (-1.0 ± 6.5)%. This precision was improved by a factor 2-3 compared to dosimetry based on planar images only. Similar results were obtained for the renal dose coefficients. The virtual patients' renal dose coefficients were (0.68 ± 0.24) Gy/GBq indicating that a population-based method yields an uncertainty of 35%. CONCLUSIONS Dosimetry based on the hybrid planar/SPECT method with OSS outperforms dosimetry based on planar images. The high variability in dose coefficients between the virtual patients demonstrates the need for individualized dosimetry.
Collapse
Affiliation(s)
- Andreas Rinscheid
- Medical Radiation Physics, Department of Nuclear Medicine, Ulm University, 89081, Ulm, Germany.,Department of Nuclear Medicine, Ulm University, 89081, Ulm, Germany
| | - Peter Kletting
- Medical Radiation Physics, Department of Nuclear Medicine, Ulm University, 89081, Ulm, Germany.,Department of Nuclear Medicine, Ulm University, 89081, Ulm, Germany
| | - Matthias Eiber
- Department of Nuclear Medicine, Klinikum Rechts der Isar, Technische Universität München, 81675, München, Germany
| | - Ambros J Beer
- Department of Nuclear Medicine, Ulm University, 89081, Ulm, Germany
| | - Gerhard Glatting
- Medical Radiation Physics, Department of Nuclear Medicine, Ulm University, 89081, Ulm, Germany.,Department of Nuclear Medicine, Ulm University, 89081, Ulm, Germany
| |
Collapse
|
15
|
A simulation-based method to determine optimal sampling schedules for dosimetry in radioligand therapy. Z Med Phys 2019; 29:314-325. [PMID: 30611606 DOI: 10.1016/j.zemedi.2018.12.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 11/13/2018] [Accepted: 12/03/2018] [Indexed: 11/20/2022]
Abstract
AIM For dosimetry in radioligand therapy, the time-integrated activity coefficients (TIACs) for organs at risk and for tumour lesions have to be determined. The used sampling scheme affects the TIACs and therefore the calculated absorbed doses. The aim of this work was to develop a general and flexible method, which analyses numerous clinically applicable sampling schedules using true time-activity curves (TACs) of virtual patients. METHOD Nine virtual patients with true TACs of the tumours were created using a physiologically-based pharmacokinetic (PBPK) model and individual biokinetic data of five patients with neuroendocrine tumours and four with meningioma. 111In-DOTATATE was used for pre-therapeutic dosimetry. In total, 15,120 sampling schemes, each consisting of 4 time points, were investigated. Gaussian noise of different levels was added to the corresponding true time-activity points. A bi-exponential function was used to fit the simulated time-activity data. For each investigated sampling schedule, 1000 replications were performed. Patient-specific and population-specific optimal sampling schedules were determined using the relative root-mean-square error (rRMSE). Furthermore, the fractions of TIACs a˜ deviating >5% (fΔa˜>5%) and >10% (fΔa˜>10%) from the true TIAC a˜true were used for additional evaluations e.g. to investigate the effect of varying single time points. RESULTS Almost all patient-specific and all population-specific optimal sampling schedules have t4≥96h for all noise levels. Changing the latest time point from the population-specific optimal time to e.g. 48h leads to a median increase of fΔa˜>10% from 0.1% to 88% for the lowest investigated noise level. Using the determined population-specific optimal schedules, results in more accurate and precise results than established schedules from the literature. CONCLUSION A method of determining the optimal sampling schedule for dosimetry, which considers clinical working hours and measurement uncertainties, has been developed and applied. The simulation study shows that optimised sampling schedules result in high accuracy and precision of the determined TIACs.
Collapse
|
16
|
Karimi Ghodoosi E, D'Alessandria C, Li Y, Bartel A, Köhner M, Höllriegl V, Navab N, Eiber M, Li WB, Frey E, Ziegler S. The effect of attenuation map, scatter energy window width, and volume of interest on the calibration factor calculation in quantitative 177Lu SPECT imaging: Simulation and phantom study. Phys Med 2018; 56:74-80. [DOI: 10.1016/j.ejmp.2018.11.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2018] [Revised: 11/07/2018] [Accepted: 11/15/2018] [Indexed: 10/27/2022] Open
|
17
|
Santoro L, Mora-Ramirez E, Trauchessec D, Chouaf S, Eustache P, Pouget JP, Kotzki PO, Bardiès M, Deshayes E. Implementation of patient dosimetry in the clinical practice after targeted radiotherapy using [ 177Lu-[DOTA0, Tyr3]-octreotate. EJNMMI Res 2018; 8:103. [PMID: 30498938 PMCID: PMC6265360 DOI: 10.1186/s13550-018-0459-4] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Accepted: 11/20/2018] [Indexed: 01/01/2023] Open
Abstract
Background This study’s aim was to develop our dosimetric methodology using a commercial workstation for the routine evaluation of the organs at risk during peptide receptor radionuclide therapy (PRRT) with 177Lu. Methods First, planar and SPECT sensitivity factors were determined on phantoms. The reconstruction parameters were optimized by SPECT/CT image acquisition using a NEMA IEC phantom containing a 500 ml bottle of 177Lu, to simulate a kidney. The recovery coefficients were determined on various phantoms. For the red marrow, this was calculated using a NEMA IEC phantom that contained a centrally placed bottle of 80 ml of 177Lu (to model the L2-L4 red marrow) flanked by two 200 ml bottles with 177Lu to simulate the kidneys. Then, SPECT/CT images were acquired at 4, 24, 72, and 192 h after injection in 12 patients with neuroendocrine tumors who underwent PRRT with 177Lu-DOTATATE. SPECT data were reconstructed using the iterative ordered subset expectation maximization (OSEM) method, with six iterations and ten subsets, attenuation, scatter, recovery resolution corrections, and a Gaussian post-filter of 0.11 cm. The liver, spleen, kidneys, and red marrow dose per administered activity (AD/A admin) values were calculated with the Medical Internal Radiation Dose (MIRD) formalism and the residence times (Dosimetry toolkit® application) using standard and CT imaging-based organ masses (OLINDA/EXM® V1.0 software). Results Sensitivity factors of 6.11 ± 0.01 and 5.67 ± 0.08 counts/s/MBq were obtained with planar and SPECT/CT acquisitions, respectively. A recovery coefficient of 0.78 was obtained for the modeled L2–L4 red marrow. The mean AD/A admin values were 0.43 ± 0.13 mGy/MBq [0.27–0.91] for kidneys, 0.54 ± 0.58 mGy/MBq [0.12–2.26] for liver, 0.61 ± 0.13 mGy/MBq [0.42–0.89] for spleen, and 0.04 ± 0.02 mGy/MBq [0.01–0.09] for red marrow. The AD/A admin values varied when calculated using the personalized and standard organ mass, particularly for kidneys (p = 1 × 10−7), spleen (p = 0.0069), and red marrow (p = 0.0027). Intra-patient differences were observed especially in organs close to or including tumor cells or metastases. Conclusions The obtained AD/A admin values were in agreement with the literature data. This study shows the technical feasibility of patient dosimetry in clinical practice and the need to obtain patient-specific information.
Collapse
Affiliation(s)
- Lore Santoro
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), University of Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex5, France.
| | - Erick Mora-Ramirez
- Centre de Recherche en Cancérologie de Toulouse, Toulouse, France.,INSERM, UMR 1037, Toulouse III Paul Sabatier University, Toulouse, France.,University of Costa Rica, Physics School, CICANUM, San Jose, Costa Rica
| | - Dorian Trauchessec
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), University of Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex5, France
| | - Soufiane Chouaf
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), University of Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex5, France
| | - Pierre Eustache
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), University of Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex5, France
| | - Jean-Pierre Pouget
- Institut de Recherche en Cancérologie de Montpellier (IRCM), INSERM U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, France
| | - Pierre-Olivier Kotzki
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), University of Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex5, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), INSERM U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, France
| | - Manuel Bardiès
- Centre de Recherche en Cancérologie de Toulouse, Toulouse, France.,INSERM, UMR 1037, Toulouse III Paul Sabatier University, Toulouse, France
| | - Emmanuel Deshayes
- Nuclear Medicine Department, Montpellier Cancer Institute (ICM), University of Montpellier, 208 Avenue des Apothicaires, 34298, Montpellier Cedex5, France.,Institut de Recherche en Cancérologie de Montpellier (IRCM), INSERM U1194, Université de Montpellier, Institut Régional du Cancer de Montpellier (ICM), Montpellier, France
| |
Collapse
|
18
|
Marin G, Vanderlinden B, Karfis I, Guiot T, Wimana Z, Reynaert N, Vandenberghe S, Flamen P. A dosimetry procedure for organs-at-risk in 177Lu peptide receptor radionuclide therapy of patients with neuroendocrine tumours. Phys Med 2018; 56:41-49. [PMID: 30527088 DOI: 10.1016/j.ejmp.2018.11.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2018] [Revised: 10/05/2018] [Accepted: 11/02/2018] [Indexed: 01/25/2023] Open
Abstract
PURPOSE Peptide receptor radionuclide therapy with 177Lu-DOTATATE has become a standard treatment modality in neuroendocrine tumours (NETs). No consensus has yet been reached however regarding the absorbed dose threshold for lesion response, the absorbed dose limit to organs-at-risk, and the optimal fractionation and activity to be administered. This is partly due to a lack of uniform and comparable dosimetry protocols. The present article details the development of an organ-at-risk dosimetry procedure, which could be implemented and used routinely in a clinical context. METHODS Forty-seven patients with NETs underwent 177Lu-DOTATATE therapy. Three SPECT/CT images were acquired at 4, 24 and 144-192 h post-injection. Three blood samples were obtained together with the SPECT/CT acquisitions and 2 additional samples were obtained around 30 min and 1 h post-injection. A bi-exponential fit was used to compute the source organ time-integrated activity coefficients. Coefficients were introduced into OLINDA/EXM software to compute organ-at-risk absorbed doses. Median values for all patients were computed for absorbed dose coefficient D/A0 and for late effective half-life T1/2eff for kidneys, spleen and red marrow. RESULTS Dosimetry resulted in a median[interquartile range] of 0.78[0.35], 1.07[0.58] and 0.028[0.010] Gy/GBq for D/A0 and of 55[9], 71[9] and 52[18] h for T1/2eff for kidneys, spleen and red marrow respectively. CONCLUSIONS A dosimetry procedure for organs-at-risk in 177Lu-DOTATATE therapy based on serial SPECT/CT images and blood samples can be implemented routinely in a clinical context with limited patient burden. The results obtained were in accordance with those of other centres.
Collapse
Affiliation(s)
- Gwennaëlle Marin
- Department of Medical Physics, Institut Jules Bordet-Université Libre de Bruxelles (ULB), 121 boulevard de Waterloo, 1000 Brussels, Belgium; Medical Imaging and Signal Processing (MEDISIP), Department of Electronics and Information Systems (ELIS), Faculty of Engineering and Architecture (FEA), Ghent University (UGent), 185 De Pintelaan, 9000 Gent, Belgium.
| | - Bruno Vanderlinden
- Department of Medical Physics, Institut Jules Bordet-Université Libre de Bruxelles (ULB), 121 boulevard de Waterloo, 1000 Brussels, Belgium.
| | - Ioannis Karfis
- Department of Nuclear Medicine, Institut Jules Bordet-Université Libre de Bruxelles (ULB), 121 boulevard de Waterloo, 1000 Brussels, Belgium.
| | - Thomas Guiot
- Department of Medical Physics, Institut Jules Bordet-Université Libre de Bruxelles (ULB), 121 boulevard de Waterloo, 1000 Brussels, Belgium.
| | - Zena Wimana
- Department of Nuclear Medicine, Institut Jules Bordet-Université Libre de Bruxelles (ULB), 121 boulevard de Waterloo, 1000 Brussels, Belgium.
| | - Nick Reynaert
- Department of Medical Physics, Institut Jules Bordet-Université Libre de Bruxelles (ULB), 121 boulevard de Waterloo, 1000 Brussels, Belgium.
| | - Stefaan Vandenberghe
- Medical Imaging and Signal Processing (MEDISIP), Department of Electronics and Information Systems (ELIS), Faculty of Engineering and Architecture (FEA), Ghent University (UGent), 185 De Pintelaan, 9000 Gent, Belgium.
| | - Patrick Flamen
- Department of Nuclear Medicine, Institut Jules Bordet-Université Libre de Bruxelles (ULB), 121 boulevard de Waterloo, 1000 Brussels, Belgium.
| |
Collapse
|