Mascolini MV, Toniolo I, Carniel EL, Fontanella CG. Ex vivo, in vivo and in silico studies of corneal biomechanics: a systematic review. Phys Eng Sci Med 2024; 47:403-441. [PMID: 38598066 PMCID: PMC11166853 DOI: 10.1007/s13246-024-01403-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 02/08/2024] [Indexed: 04/11/2024]
Abstract
Healthy cornea guarantees the refractive power of the eye and the protection of the inner components, but injury, trauma or pathology may impair the tissue shape and/or structural organization and therefore its material properties, compromising its functionality in the ocular visual process. It turns out that biomechanical research assumes an essential role in analysing the morphology and biomechanical response of the cornea, preventing pathology occurrence, and improving/optimising treatments. In this review, ex vivo, in vivo and in silico methods for the corneal mechanical characterization are reported. Experimental techniques are distinct in testing mode (e.g., tensile, inflation tests), samples' species (human or animal), shape and condition (e.g., healthy, treated), preservation methods, setup and test protocol (e.g., preconditioning, strain rate). The meaningful results reported in the pertinent literature are discussed, analysing differences, key features and weaknesses of the methodologies adopted. In addition, numerical techniques based on the finite element method are reported, incorporating the essential steps for the development of corneal models, such as geometry, material characterization and boundary conditions, and their application in the research field to extend the experimental results by including further relevant aspects and in the clinical field for diagnostic procedure, treatment and planning surgery. This review aims to analyse the state-of-art of the bioengineering techniques developed over the years to study the corneal biomechanics, highlighting their potentiality to improve diagnosis, treatment and healing process of the corneal tissue, and, at the same, pointing out the current limits in the experimental equipment and numerical tools that are not able to fully characterize in vivo corneal tissues non-invasively and discourage the use of finite element models in daily clinical practice for surgical planning.
Collapse
Affiliation(s)
- Maria Vittoria Mascolini
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| | - Ilaria Toniolo
- Department of Industrial Engineering, University of Padova, Padova, Italy.
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy.
| | - Emanuele Luigi Carniel
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| | - Chiara Giulia Fontanella
- Department of Industrial Engineering, University of Padova, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padova, Padova, Italy
| |
Collapse
|
2
|
Pan M, Kwok S, Pan X, Liu J. Biomechanical Correlations Between the Cornea and the Optic Nerve Head. Invest Ophthalmol Vis Sci 2024; 65:34. [PMID: 38776117 PMCID: PMC11127493 DOI: 10.1167/iovs.65.5.34] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 05/10/2024] [Indexed: 05/27/2024] Open
Abstract
Purpose A thin cornea is a potent risk factor for glaucoma. The underlying mechanisms remain unexplained. It has been postulated that central corneal thickness (CCT) may be a surrogate for biomechanical parameters of the posterior eye. In this study, we aimed to explore correlations of biomechanical responses between the cornea and the optic nerve head (ONH) and the peripapillary sclera (PPS) to elevated intraocular pressure (IOP), the primary risk factor of glaucoma. Methods Inflation tests were performed in nine pairs of human donor globes. One eye of each pair was randomly assigned for cornea or posterior eye inflation. IOP was raised from 5 to 30 millimeters of mercury (mmHg) at 0.5 mmHg steps in the whole globe and the cornea or the ONH/PPS was imaged using a 50 MHz ultrasound probe. Correlation-based ultrasound speckle tracking was used to calculate tissue displacements and strains. Associations of radial, tangential, and shear strains at 30 mmHg between the cornea and the ONH or PPS were evaluated. Results Corneal shear strain was significantly correlated with ONH shear strain (R = 0.857, P = 0.003) and PPS shear strain (R = 0.724, P = 0.028). CCT was not correlated with any strains in the cornea, ONH, or PPS. Conclusions Our results suggested that an eye that experiences a larger shear strain in the cornea would likely experience a larger shear strain in its ONH and PPS at IOP elevations. The strong correlation between the cornea's and the ONH's shear response to IOP provides new insights and suggests a plausible explanation of the cornea's connection to glaucoma risk.
Collapse
Affiliation(s)
- Manqi Pan
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, United States
| | - Sunny Kwok
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, United States
| | - Xueliang Pan
- Department of Biomedical Informatics, The Ohio State University, Columbus, Ohio, United States
| | - Jun Liu
- Department of Biomedical Engineering, The Ohio State University, Columbus, Ohio, United States
- Department of Ophthalmology and Visual Sciences, The Ohio State University, Columbus, Ohio, United States
| |
Collapse
|
3
|
Neri S, Mascolini MV, Peruffo A, Todros S, Zuin M, Cordaro L, Martines E, Contiero B, Carniel EL, Iacopetti I, Patruno M, Fontanella CG, Perazzi A. How does atmospheric pressure cold helium plasma affect the biomechanical behaviour on alkali-lesioned corneas? BMC Vet Res 2024; 20:153. [PMID: 38659026 PMCID: PMC11041036 DOI: 10.1186/s12917-024-03980-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 03/15/2024] [Indexed: 04/26/2024] Open
Abstract
BACKGROUND Melting corneal ulcers are a serious condition that affects a great number of animals and people around the world and it is characterised by a progressive weakening of the tissue leading to possible severe ophthalmic complications, such as visual impairment or blindness. This disease is routinely treated with medical therapy and keratoplasty, and recently also with alternative regenerative therapies, such as cross-linking, amniotic membrane transplant, and laser. Plasma medicine is another recent example of regenerative treatment that showed promising results in reducing the microbial load of corneal tissue together with maintaining its cellular vitality. Since the effect of helium plasma application on corneal mechanical viscoelasticity has not yet been investigated, the aim of this study is first to evaluate it on ex vivo porcine corneas for different exposition times and then to compare the results with previous data on cross-linking treatment. RESULTS 94 ex vivo porcine corneas divided into 16 populations (healthy or injured, fresh or cultured and treated or not with plasma or cross-linking) were analysed. For each population, a biomechanical analysis was performed by uniaxial stress-relaxation tests, and a statistical analysis was carried out considering the characteristic mechanical parameters. In terms of equilibrium normalised stress, no statistically significant difference resulted when the healthy corneas were compared with lesioned plasma-treated ones, independently of treatment time, contrary to what was obtained about the cross-linking treated corneas which exhibited more intense relaxation phenomena. CONCLUSIONS In this study, the influence of the Helium plasma treatment was observed on the viscoelasticity of porcine corneas ex vivo, by restoring in lesioned tissue a degree of relaxation similar to the one of the native tissue, even after only 2 min of application. Therefore, the obtained results suggest that plasma treatment is a promising new regenerative ophthalmic therapy for melting corneal ulcers, laying the groundwork for further studies to correlate the mechanical findings with corneal histology and ultrastructural anatomy after plasma treatment.
Collapse
Affiliation(s)
- Simona Neri
- Department of Animal Medicine, Production and Health, University of Padua, Padova, Italy.
| | - Maria Vittoria Mascolini
- Department of Industrial Engineering, University of Padua, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padua, Padova, Italy
| | - Antonella Peruffo
- Department of Comparative Biomedicine and Food Science, University of Padua, Padova, Italy.
| | - Silvia Todros
- Department of Industrial Engineering, University of Padua, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padua, Padova, Italy
| | - Matteo Zuin
- RFX (CNR, ENEA, INFN), Padova, Italy
- CNR, Institute for Plasma Science and Technology, Padova, Italy
| | - Luigi Cordaro
- RFX (CNR, ENEA, INFN), Padova, Italy
- CNR, Institute for Plasma Science and Technology, Padova, Italy
| | - Emilio Martines
- Department of Physics "G. Occhialini", University of Milano - Bicocca, Milano, Italy
| | - Barbara Contiero
- Department of Animal Medicine, Production and Health, University of Padua, Padova, Italy
| | - Emanuele Luigi Carniel
- Department of Industrial Engineering, University of Padua, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padua, Padova, Italy
| | - Ilaria Iacopetti
- Department of Animal Medicine, Production and Health, University of Padua, Padova, Italy
| | - Marco Patruno
- Department of Comparative Biomedicine and Food Science, University of Padua, Padova, Italy
| | - Chiara Giulia Fontanella
- Department of Industrial Engineering, University of Padua, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padua, Padova, Italy
| | - Anna Perazzi
- Department of Animal Medicine, Production and Health, University of Padua, Padova, Italy
- Centre for Mechanics of Biological Materials, University of Padua, Padova, Italy
| |
Collapse
|
4
|
Shih HJ, Cheng SC, Shih PJ. Experimental evaluation of corneal stress-optic coefficients using a pair of force test. J Mech Behav Biomed Mater 2024; 152:106454. [PMID: 38354567 DOI: 10.1016/j.jmbbm.2024.106454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 01/04/2024] [Accepted: 01/31/2024] [Indexed: 02/16/2024]
Abstract
BACKGROUND Topography and tomography are valuable techniques for measuring the corneal shape, but they cannot directly assess its internal mechanical stresses. And nonuniform corneal stress plays a crucial biomechanical role in the progression of diseases and postoperative changes. Given the cornea's inherent transparency, analyzing corneal stresses using the photoelasticity method is highly advantageous. However, quantification of photoelasticity faces challenges in obtaining the stress-optic coefficient due to wrinkles caused by the non-spherical geometry during tensional experiments. OBJECTIVE In this study, we propose an innovative experimental setup aimed at generating a gradient field of simple shear stress and achieving surface flatness during corneal stretching experiments, enabling the acquisition of the stress-optic coefficient through comparison with numerical results. METHODS Our designed setup applies fluid pressure and force couples on the cornea. The internal fluid pressure maintains the corneal shape, preventing wrinkles, while the force couples create a stress field leading to isochromatic fringes. RESULTS We successfully measured the stress-optic coefficients of the porcine anisotropic cornea in ex-vivo as 1.87 × 10-9 (horizontal) and 1.97 × 10-9 (vertical) (m2/N). Each isochromatic fringe order represents a shear stress range of 6.05 × 104 Pa under a low tension. CONCLUSIONS This study establishes a significant connection between corneal photoelastic patterns and the quantification of corneal stress by enabling direct measurement through advanced photoelastic visualization technology for clinical applications.
Collapse
Affiliation(s)
- Hua-Ju Shih
- Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan
| | - Shan-Chien Cheng
- Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan
| | - Po-Jen Shih
- Department of Biomedical Engineering, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|
5
|
Mekonnen T, Zevallos-Delgado C, Singh M, Aglyamov SR, Larin KV. Multifocal acoustic radiation force-based reverberant optical coherence elastography for evaluation of ocular globe biomechanical properties. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:095001. [PMID: 37701876 PMCID: PMC10494982 DOI: 10.1117/1.jbo.28.9.095001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 08/01/2023] [Accepted: 08/28/2023] [Indexed: 09/14/2023]
Abstract
Significance Quantifying the biomechanical properties of the whole eye globe can provide a comprehensive understanding of the interactions among interconnected ocular components during dynamic physiological processes. By doing so, clinicians and researchers can gain valuable insights into the mechanisms underlying ocular diseases, such as glaucoma, and design interventions tailored to each patient's unique needs. Aim The aim of this study was to evaluate the feasibility and effectiveness of a multifocal acoustic radiation force (ARF) based reverberant optical coherence elastography (RevOCE) technique for quantifying shear wave speeds in different ocular components simultaneously. Approach We implemented a multifocal ARF technique to generate reverberant shear wave fields, which were then detected using phase-sensitive optical coherence tomography. A 3D-printed acoustic lens array was employed to manipulate a collimated ARF beam generated by an ultrasound transducer, producing multiple focused ARF beams on mouse eye globes ex vivo. RevOCE measurements were conducted using an excitation pulse train consisting of 10 cycles at 3 kHz, followed by data processing to produce a volumetric map of the shear wave speed. Results The results show that the system can successfully generate reverberant shear wave fields in the eye globe, allowing for simultaneous estimation of shear wave speeds in various ocular components, including cornea, iris, lens, sclera, and retina. A comparative analysis revealed notable differences in wave speeds between different parts of the eye, for example, between the apical region of the cornea and the pupillary zone of the iris (p = 0.003 ). Moreover, the study also revealed regional variations in the biomechanical properties of ocular components as evidenced by greater wave speeds near the apex of the cornea compared to its periphery. Conclusions The study demonstrated the effectiveness of RevOCE based on a non-invasive multifocal ARF for assessing the biomechanical properties of the whole eyeball. The findings indicate the potential to provide a comprehensive understanding of the mechanical behavior of the whole eye, which could lead to improved diagnosis and treatment of ocular diseases.
Collapse
Affiliation(s)
- Taye Mekonnen
- University of Houston, Department of Biomedical Engineering Houston, Texas, United States
| | | | - Manmohan Singh
- University of Houston, Department of Biomedical Engineering Houston, Texas, United States
| | - Salavat R. Aglyamov
- University of Houston, Department of Mechanical Engineering, Houston, Texas, United States
| | - Kirill V. Larin
- University of Houston, Department of Biomedical Engineering Houston, Texas, United States
| |
Collapse
|
6
|
Makarem A, Abass A, Bao F, Elsheikh A. Assessment of age-related change of the ocular support system. Front Bioeng Biotechnol 2023; 11:1146828. [PMID: 37492801 PMCID: PMC10363727 DOI: 10.3389/fbioe.2023.1146828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 06/23/2023] [Indexed: 07/27/2023] Open
Abstract
To estimate the material stiffness of the orbital soft tissue in human orbits using an inverse numerical analysis approach, which could be used in future studies to understand the behaviour under dynamic, non-contact tonometry or simulate various ophthalmological conditions. Clinical data were obtained for the left eye of 185 Chinese participants subjected to a complete ophthalmic examination, including tests by the Corvis ST and Pentacam. 185 numerical models of the eye globes were built with idealised geometry of the sclera while considering the corneal tomography measured by the Pentacam. The models were extended to include representations of the orbital soft tissue (OST), which were given idealised geometry. The movement of the whole eye in response to an air-puff directed at the central cornea was examined and used in an inverse analysis process to estimate the biomechanical stiffness parameters of the OST. The results indicated a weak correlation of E t with the progression of age, regardless of the stress at which E t was calculated. However, there was evidence of significant differences in E t between some of the age groups. There was statistical evidence of significant differences between E t in the age range 20< years < 43 relative to E t in OST with age ranges 43< years < 63 (p = 0.022) and 63< years < 91 (p = 0.011). In contrast, E t in OST with age ranges 43< years < 63 and 63< years < 91 were not significantly different (p = 0.863). The optimised mechanical properties of the OST were found to be almost four times stiffer than properties of fatty tissue of previous experimental work. This study consolidated previous findings of the role of extraocular muscles on the ocular suppor system. In addition, the rotation of the globe during corvis loading is suggested to be of posterior components of the globe and shall be further investigated.
Collapse
Affiliation(s)
- Ahmed Makarem
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
| | - Ahmed Abass
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
- Faculty of Engineering, Port Said University, Port Fouad, Egypt
| | - Fangjun Bao
- School of Optometry and Ophthalmology and Eye Hospital, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, China
- National Institute for Health Research (NIHR), Biomedical Research Centre at Moorfields Eye Hospital NHS Foundation Trust, UCL Institute of Ophthalmology, London, United Kingdom
| |
Collapse
|
7
|
Ross AKM, Schlunck G, Böhringer D, Maier P, Eberwein P, Reinhard T, Lang SJ. Characterization of the Immediate and Delayed Biomechanical Response to UV-A Crosslinking of Human Corneas. Cornea 2023; Publish Ahead of Print:00003226-990000000-00318. [PMID: 37335854 DOI: 10.1097/ico.0000000000003336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 05/26/2023] [Indexed: 06/21/2023]
Abstract
PURPOSE Keratoconus leads to visual deterioration due to irregular astigmatism and corneal thinning. Riboflavin-based corneal UV-A crosslinking (CXL) induces novel intramolecular and intermolecular links resulting in corneal tissue stiffening, thereby halting disease progression. The purpose of this study was to analyze the immediate and delayed biomechanical responses of human donor corneas to CXL. METHODS CXL was performed according to the Dresden protocol to corneas not suitable for transplantation. Biomechanical properties were subsequently monitored by measuring the Young modulus using nanoindentation. The immediate tissue response was determined after 0, 1, 15, and 30 minutes of irradiation. Delayed biomechanical effects were investigated with follow-up measurements immediately and 1, 3, and 7 days after CXL. RESULTS Young's modulus indicated a linear trend in direct response to increasing irradiation times (mean values: total 61.31 kPa [SD 25.53], 0 minutes 48.82 kPa [SD 19.73], 1 minute 53.44 kPa [SD 25.95], 15 minutes 63.56 kPa [SD 20.99], and 30 minutes 76.76 kPa [SD 24.92]). The linear mixed model for the elastic response of corneal tissue was 49.82 kPa + (0.91 kPa/min × time [minutes]); P < 0.001. The follow-up measurements showed no significant delayed changes in the Young modulus (mean values: total 55,28 kPa [SD 15.95], immediately after CXL 56,83 kPa [SD 18.74], day 1 50.28 kPa [SD 14.15], day 3 57.08 kPa [SD 14.98], and day 7 56.83 kPa [SD 15.07]). CONCLUSIONS This study suggests a linear increase of corneal Young modulus as a function of CXL timing. No significant short-term delayed biomechanical changes posttreatment were observed.
Collapse
Affiliation(s)
- Andrea K M Ross
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Günther Schlunck
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Daniel Böhringer
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Philip Maier
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | | | - Thomas Reinhard
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| | - Stefan Johann Lang
- Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Freiburg, Germany; and
| |
Collapse
|
8
|
Cabeza-Gil I, Frechilla J, Calvo B. Evaluation of the mechanical stability of intraocular lenses using digital image correlation. Sci Rep 2023; 13:9437. [PMID: 37296225 PMCID: PMC10256795 DOI: 10.1038/s41598-023-36694-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 06/08/2023] [Indexed: 06/12/2023] Open
Abstract
This study aimed to evaluate the mechanical stability of seven different intraocular lens (IOL) haptic designs by using digital image correlation to measure their mechanical biomarkers (axial displacement, tilt, and rotation) under quasi-static compression. The IOLs were compressed between two clamps from 11.00 up to 9.50 mm whilst a 3D deformation dataset was acquired every 0.04 mm. Results revealed that flexible and mixed IOL designs exhibited better mechanical response for smaller compression diameters compared to stiff designs. Conversely, stiff designs performed better for larger compression diameters. These findings may aid in the selection and development of more mechanically stable IOL designs.
Collapse
Affiliation(s)
- Iulen Cabeza-Gil
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Zaragoza, Spain.
| | - Javier Frechilla
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Zaragoza, Spain
| | - Begoña Calvo
- Aragón Institute of Engineering Research (i3A), University of Zaragoza, Zaragoza, Spain
- Biomaterials and Nanomedicine Networking Biomedical Research Centre (CIBER-BBN), Zaragoza, Spain
| |
Collapse
|
9
|
Foong TY, Hua Y, Amini R, Sigal IA. Who bears the load? IOP-induced collagen fiber recruitment over the corneoscleral shell. Exp Eye Res 2023; 230:109446. [PMID: 36935071 PMCID: PMC10133210 DOI: 10.1016/j.exer.2023.109446] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2022] [Revised: 02/25/2023] [Accepted: 03/16/2023] [Indexed: 03/19/2023]
Abstract
Collagen is the main load-bearing component of cornea and sclera. When stretched, both of these tissues exhibit a behavior known as collagen fiber recruitment. In recruitment, as the tissues stretch the constitutive collagen fibers lose their natural waviness, progressively straightening. Recruited, straight, fibers bear substantially more mechanical load than non-recruited, wavy, fibers. As such, the process of recruitment underlies the well-established nonlinear macroscopic behavior of the corneoscleral shell. Recruitment has an interesting implication: when recruitment is incomplete, only a fraction of the collagen fibers is actually contributing to bear the loads, with the rest remaining "in reserve". In other words, at a given intraocular pressure (IOP), it is possible that not all the collagen fibers of the cornea and sclera are actually contributing to bear the loads. To the best of our knowledge, the fraction of corneoscleral shell fibers recruited and contributing to bear the load of IOP has not been reported. Our goal was to obtain regionally-resolved estimates of the fraction of corneoscleral collagen fibers recruited and in reserve. We developed a fiber-based microstructural constitutive model that could account for collagen fiber undulations or crimp via their tortuosity. We used experimentally-measured collagen fiber crimp tortuosity distributions in human eyes to derive region-specific nonlinear hyperelastic mechanical properties. We then built a three-dimensional axisymmetric model of the globe, assigning region-specific mechanical properties and regional anisotropy. The model was used to simulate the IOP-induced shell deformation. The model-predicted tissue stretch was then used to quantify collagen recruitment within each shell region. The calculations showed that, at low IOPs, collagen fibers in the posterior equator were recruited the fastest, such that at a physiologic IOP of 15 mmHg, over 90% of fibers were recruited, compared with only a third in the cornea and the peripapillary sclera. The differences in recruitment between regions, in turn, mean that at a physiologic IOP the posterior equator had a fiber reserve of only 10%, whereas the cornea and peripapillary sclera had two thirds. At an elevated IOP of 50 mmHg, collagen fibers in the limbus and the anterior/posterior equator were almost fully recruited, compared with 90% in the cornea and the posterior sclera, and 70% in the peripapillary sclera and the equator. That even at such an elevated IOP not all the fibers were recruited suggests that there are likely other conditions that challenge the corneoscleral tissues even more than IOP. The fraction of fibers recruited may have other potential implications. For example, fibers that are not bearing loads may be more susceptible to enzymatic digestion or remodeling. Similarly, it may be possible to control tissue stiffness through the fraction of recruited fibers without the need to add or remove collagen.
Collapse
Affiliation(s)
- Tian Yong Foong
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, United States; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
| | - Yi Hua
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, United States; Department of Biomedical Engineering, University of Mississippi, MS, United States; Department of Mechanical Engineering, University of Mississippi, MS, United States
| | - Rouzbeh Amini
- Department of Mechanical and Industrial Engineering, Northeastern University, Boston, MA, United States; Department of Bioengineering, Northeastern University, Boston, MA, United States
| | - Ian A Sigal
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, United States; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States; McGowan Institute for Regenerative Medicine, University of Pittsburgh Medical Center and University of Pittsburgh, Pittsburgh, PA, United States.
| |
Collapse
|
10
|
Towler J, Consejo A, Zhou D, Romano V, Levis H, Boote C, Elsheikh A, Geraghty B, Abass A. Typical localised element-specific finite element anterior eye model. Heliyon 2023; 9:e13944. [PMID: 37101628 PMCID: PMC10123217 DOI: 10.1016/j.heliyon.2023.e13944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2022] [Revised: 11/19/2022] [Accepted: 02/15/2023] [Indexed: 03/07/2023] Open
Abstract
Purpose The study presents an averaged anterior eye geometry model combined with a localised material model that is straightforward, appropriate and amenable for implementation in finite element (FE) modelling. Methods Both right and left eye profile data of 118 subjects (63 females and 55 males) aged 22-67 years (38.5 ± 7.6) were used to build an averaged geometry model. Parametric representation of the averaged geometry model was achieved through two polynomials dividing the eye into three smoothly connected volumes. This study utilised the collagen microstructure x-ray data of 6 ex-vivo healthy human eyes, 3 right eyes and 3 left eyes in pairs from 3 donors, 1 male and 2 females aged between 60 and 80 years, to build a localised element-specific material model for the eye. Results Fitting the cornea and the posterior sclera sections to a 5th-order Zernike polynomial resulted in 21 coefficients. The averaged anterior eye geometry model recorded a limbus tangent angle of 37° at a radius of 6.6 mm from the corneal apex. In terms of material models, the difference between the stresses generated in the inflation simulation up to 15 mmHg in the ring-segmented material model and localised element-specific material model were significantly different (p < 0.001) with the ring-segmented material model recording average Von-Mises stress 0.0168 ± 0.0046 MPa and the localised element-specific material model recording average Von-Mises stress 0.0144 ± 0.0025 MPa. Conclusions The study illustrates an averaged geometry model of the anterior human eye that is easy to generate through two parametric equations. This model is combined with a localised material model that can be used either parametrically through a Zernike fitted polynomial or non-parametrically as a function of the azimuth angle and the elevation angle of the eye globe. Both averaged geometry and localised material models were built in a way that makes them easy to implement in FE analysis without additional computation cost compared to the limbal discontinuity so-called idealised eye geometry model or ring-segmented material model.
Collapse
Affiliation(s)
- Joseph Towler
- Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | | | - Dong Zhou
- Department of Civil Engineering and Industrial Design, School of Engineering, University of Liverpool, Liverpool, UK
| | - Vito Romano
- Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
- Department of Medical and Surgical Specialities, Radiological Sciences, And Public Health, Ophthalmology Clinic, University of Brescia, Italy
| | - Hannah Levis
- Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | - Craig Boote
- School of Optometry and Vision Sciences, Cardiff University, Cardiff, UK
| | - Ahmed Elsheikh
- Department of Civil Engineering and Industrial Design, School of Engineering, University of Liverpool, Liverpool, UK
- Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing, China
- NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
| | - Brendan Geraghty
- Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
| | - Ahmed Abass
- Department of Mechanical, Materials and Aerospace Engineering, School of Engineering, University of Liverpool, Liverpool, UK
- Department of Production Engineering and Mechanical Design, Faculty of Engineering, Port Said University, Egypt
| |
Collapse
|
11
|
Biomechanics of keratoconus: Two numerical studies. PLoS One 2023; 18:e0278455. [PMID: 36730305 PMCID: PMC9894483 DOI: 10.1371/journal.pone.0278455] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Accepted: 11/16/2022] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND The steep cornea in keratoconus can greatly impair eyesight. The etiology of keratoconus remains unclear but early injury that weakens the corneal stromal architecture has been implicated. To explore keratoconus mechanics, we conducted two numerical simulation studies. METHODS A finite-element model describing the five corneal layers and the heterogeneous mechanical behaviors of the ground substance and lamellar collagen-fiber architecture in the anterior and posterior stroma was developed using the Holzapfel-Gasser-Ogden constitutive model. The geometry was from a healthy subject. Its stroma was divided into anterior, middle, and posterior layers to assess the effect of changing regional mechanical parameters on corneal displacement and maximum principal stress under intraocular pressure. Specifically, the effect of softening an inferocentral corneal button, the collagen-based tissues throughout the whole cornea, or specific stromal layers in the button was examined. The effect of simply disorganizing the orthogonally-oriented posterior stromal fibers in the button was also assessed. The healthy cornea was also subjected to eye rubbing-like loading to identify the corneal layer(s) that experienced the most tensional stress. RESULTS Conical deformation and corneal thinning emerged when the corneal button or the mid-posterior stroma of the button underwent gradual softening or when the collagen fibers in the mid-posterior stroma of the button were dispersed. Softening the anterior layers of the button or the whole cornea did not evoke conical deformation. Button softening greatly increased and disrupted the stress on Bowman's membrane while mid-posterior stromal softening increased stress in the anterior layers. Eye rubbing profoundly stressed the deep posterior stroma while other layers were negligibly affected. DISCUSSION These observations suggest that keratoconus could be initiated, at least partly, by mechanical instability/damage in the mid-posterior stroma that then imposes stress on the anterior layers. This may explain why subclinical keratoconus is marked by posterior but not anterior elevation on videokeratoscopy.
Collapse
|
12
|
Wei J, Hua Y, Yang B, Wang B, Schmitt SE, Wang B, Lucy KA, Ishikawa H, Schuman JS, Smith MA, Wollstein G, Sigal IA. Comparing Acute IOP-Induced Lamina Cribrosa Deformations Premortem and Postmortem. Transl Vis Sci Technol 2022; 11:1. [DOI: 10.1167/tvst.11.12.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Affiliation(s)
- Junchao Wei
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Yi Hua
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Bin Yang
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Engineering, Duquesne University, Pittsburgh, PA, USA
| | - Bo Wang
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Samantha E. Schmitt
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
- Neuroscience Institute, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Bingrui Wang
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Katie A. Lucy
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, USA
| | - Hiroshi Ishikawa
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, USA
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA
- Department of Medical Informatics and Clinical Epidemiology, Oregon Health & Science University, Portland, OR, USA
| | - Joel S. Schuman
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, USA
- Department of Biomedical Engineering and Electrical and Computer Engineering, New York University Tandon School of Engineering, Brooklyn, NY, USA
- Neuroscience Institute, NYU Langone Health, New York, NY, USA
| | - Matthew A. Smith
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
- Neuroscience Institute, Carnegie Mellon University, Pittsburgh, PA, USA
| | - Gadi Wollstein
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY, USA
| | - Ian A. Sigal
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| |
Collapse
|
13
|
Co-axial acoustic-based optical coherence vibrometry probe for the quantification of resonance frequency modes in ocular tissue. Sci Rep 2022; 12:18834. [PMID: 36336702 PMCID: PMC9637745 DOI: 10.1038/s41598-022-21978-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 10/07/2022] [Indexed: 11/08/2022] Open
Abstract
We present a co-axial acoustic-based optical coherence vibrometry probe (CoA-OCV) for vibro-acoustic resonance quantification in biological tissues. Sample vibrations were stimulated via a loudspeaker, and pre-compensation was used to calibrate the acoustic spectrum. Sample vibrations were measured via phase-sensitive swept-source optical coherence tomography (OCT). Resonance frequencies of corneal phantoms were measured at varying intraocular pressures (IOP), and dependencies on Young´s Modulus (E), phantom thickness and IOP were observed. Cycling IOP revealed hysteresis. For E = 0.3 MPa, resonance frequencies increased with IOP at a rate of 3.9, 3.7 and 3.5 Hz/mmHg for varied thicknesses and 1.7, 2.5 and 2.8 Hz/mmHg for E = 0.16 MPa. Resonance frequencies increased with thickness at a rate of 0.25 Hz/µm for E = 0.3 MPa, and 0.40 Hz/µm for E = 0.16 MPa. E showed the most predominant impact in the shift of the resonance frequencies. Full width at half maximum (FWHM) of the resonance modes increased with increasing thickness and decreased with increasing E. Only thickness and E contributed to the variance of FWHM. In rabbit corneas, resonance frequencies of 360-460 Hz were observed. The results of the current study demonstrate the feasibility of CoA-OCV for use in future OCT-V studies.
Collapse
|
14
|
Vinas-Pena M, Feng X, Li GY, Yun SH. In situ measurement of the stiffness increase in the posterior sclera after UV-riboflavin crosslinking by optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2022; 13:5434-5446. [PMID: 36425630 PMCID: PMC9664890 DOI: 10.1364/boe.463600] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 08/08/2022] [Accepted: 08/09/2022] [Indexed: 06/16/2023]
Abstract
Scleral crosslinking may provide a way to prevent or treat myopia by stiffening scleral tissues. The ability to measure the stiffness of scleral tissues in situ pre and post scleral crosslinking would be useful but has not been established. Here, we tested the feasibility of optical coherence elastography (OCE) to measure shear modulus of scleral tissues and evaluate the impact of crosslinking on different posterior scleral regions using ex vivo porcine eyes as a model. From measured elastic wave speeds at 6 - 16 kHz, we obtained out-of-plane shear modulus value of 0.71 ± 0.12 MPa (n = 20) for normal porcine scleral tissues. After riboflavin-assisted UV crosslinking, the shear modulus increased to 1.50 ± 0.39 MPa (n = 20). This 2-fold change was consistent with the increase of static Young's modulus from 5.5 ± 1.1 MPa to 9.3 ± 1.9 MPa after crosslinking, which we measured using conventional uniaxial extensometry on tissue stripes. OCE revealed regional stiffness differences across the temporal, nasal, and deeper posterior sclera. Our results show the potential of OCE as a noninvasive tool to evaluate the effect of scleral crosslinking.
Collapse
|
15
|
Tropocollagen springs allow collagen fibrils to stretch elastically. Acta Biomater 2022; 142:185-193. [PMID: 35081430 PMCID: PMC8982519 DOI: 10.1016/j.actbio.2022.01.041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 01/17/2022] [Accepted: 01/18/2022] [Indexed: 11/28/2022]
Abstract
The mechanical properties of connective tissues are tailored to their specific function, and changes can lead to dysfunction and pathology. In most mammalian tissues the mechanical environment is governed by the micro- and nano-scale structure of collagen and its interaction with other tissue components, however these hierarchical properties remain poorly understood. In this study we use the human cornea as a model system to characterise and quantify the dominant deformation mechanisms of connective tissue in response to cyclic loads of physiological magnitude. Synchronised biomechanical testing, x-ray scattering and 3D digital image correlation revealed the presence of two dominant mechanisms: collagen fibril elongation due to a largely elastic, spring-like straightening of tropocollagen supramolecular twist, and a more viscous straightening of fibril crimp that gradually increased over successive loading cycles. The distinct mechanical properties of the two mechanisms suggest they have separate roles in vivo. The elastic, spring-like mechanism is fast-acting and likely responds to stresses associated with the cardiac cycle, while the more viscous crimp mechanism will respond to slower processes, such as postural stresses. It is anticipated that these findings will have broad applicability to understanding the normal and pathological functioning of other connective tissues such as skin and blood vessels that exhibit both helical structures and crimp. Statement of significance The tropocollagen spring mechanism allows collagen fibrils from some tissues to elongate significantly under small loads, and its recent discovery has the potential to change our fundamental understanding of how tissue deforms. This time-resolved study quantifies the contribution of the spring mechanism to the local strain in stretched tissue and compares it to the contribution associated with the straightening of fibril waviness, the widely accepted primary low-load strain mechanism. The spring mechanism contributed more to the local tissue strain than fibril straightening, and was found to be elastic while fibril straightening was more viscous. The results suggest that the viscoelastic behaviour of a biomaterial is controlled, at least in part, by the relative amount of fibril-scale crimp and tropocollagen supramolecular twist.
Collapse
|
16
|
Fontanella CG, Carniel EL, Corain L, Peruffo A, Iacopetti I, Pavan PG, Todros S, Perazzi A. Mechanical behaviour of healthy versus alkali-lesioned corneas by a porcine organ culture model. BMC Vet Res 2021; 17:340. [PMID: 34711207 PMCID: PMC8555156 DOI: 10.1186/s12917-021-03050-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Accepted: 09/24/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cornea is a composite tissue exhibiting nonlinear and time-dependent mechanical properties. Corneal ulcers are one of the main pathologies that affect this tissue, disrupting its structural integrity and leading to impaired functions. In this study, uniaxial tensile and stress-relaxation tests are developed to evaluate stress-strain and time-dependent mechanical behaviour of porcine corneas. RESULTS The samples are split in two groups: some corneas are analysed in an unaltered state (healthy samples), while others are injured with alkaline solution to create an experimental ulcer (lesioned samples). Furthermore, within each group, corneas are examined in two conditions: few hours after the enucleation (fresh samples) or after 7 days in a specific culture medium for the tissue (cultured samples). Finally, another condition is added: corneas from all the groups undergo or not a cross-linking treatment. In both stress-strain and stress-relaxation tests, a weakening of the tissue is observed due to the imposed conditions (lesion, culture and treatment), represented by a lower stiffness and increased stress-relaxation. CONCLUSIONS Alkali-induced corneal stromal melting determines changes in the mechanical response that can be related to a damage at microstructural level. The results of the present study represent the basis for the investigation of traditional and innovative corneal therapies.
Collapse
Affiliation(s)
- Chiara Giulia Fontanella
- Department of Industrial Engineering, University of Padova, via Venezia 1, 35131, Padova, Italy.,Centre for Mechanics of Biological Materials, University of Padova, via Marzolo 9, 35131, Padova, Italy
| | - Emanuele Luigi Carniel
- Department of Industrial Engineering, University of Padova, via Venezia 1, 35131, Padova, Italy.,Centre for Mechanics of Biological Materials, University of Padova, via Marzolo 9, 35131, Padova, Italy
| | - Livio Corain
- Department of Management and Engineering, University of Padova, stradella S. Nicola 3, 36100, Vicenza, Italy
| | - Antonella Peruffo
- Department of Comparative Biomedicine and Food Science, University of Padova, viale dell'Università 16, Legnaro, 35020, Padova, Italy
| | - Ilaria Iacopetti
- Department of Animal Medicine, Production and Health, University of Padova, viale dell'Università 16, Legnaro, 35020, Padova, Italy
| | - Piero G Pavan
- Department of Industrial Engineering, University of Padova, via Venezia 1, 35131, Padova, Italy.,Centre for Mechanics of Biological Materials, University of Padova, via Marzolo 9, 35131, Padova, Italy
| | - Silvia Todros
- Department of Industrial Engineering, University of Padova, via Venezia 1, 35131, Padova, Italy. .,Centre for Mechanics of Biological Materials, University of Padova, via Marzolo 9, 35131, Padova, Italy.
| | - Anna Perazzi
- Department of Animal Medicine, Production and Health, University of Padova, viale dell'Università 16, Legnaro, 35020, Padova, Italy
| |
Collapse
|
17
|
Bronte-Ciriza D, Birkenfeld JS, de la Hoz A, Curatolo A, Germann JA, Villegas L, Varea A, Martínez-Enríquez E, Marcos S. Estimation of scleral mechanical properties from air-puff optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:6341-6359. [PMID: 34745741 PMCID: PMC8548012 DOI: 10.1364/boe.437981] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2021] [Revised: 08/15/2021] [Accepted: 08/15/2021] [Indexed: 05/11/2023]
Abstract
We introduce a method to estimate the biomechanical properties of the porcine sclera in intact eye globes ex vivo, using optical coherence tomography that is coupled with an air-puff excitation source, and inverse optimization techniques based on finite element modeling. Air-puff induced tissue deformation was determined at seven different locations on the ocular globe, and the maximum apex deformation, the deformation velocity, and the arc-length during deformation were quantified. In the sclera, the experimental maximum deformation amplitude and the corresponding arc length were dependent on the location of air-puff excitation. The normalized temporal deformation profile of the sclera was distinct from that in the cornea, but similar in all tested scleral locations, suggesting that this profile is independent of variations in scleral thickness. Inverse optimization techniques showed that the estimated scleral elastic modulus ranged from 1.84 ± 0.30 MPa (equatorial inferior) to 6.04 ± 2.11 MPa (equatorial temporal). The use of scleral air-puff imaging holds promise for non-invasively investigating the structural changes in the sclera associated with myopia and glaucoma, and for monitoring potential modulation of scleral stiffness in disease or treatment.
Collapse
Affiliation(s)
- David Bronte-Ciriza
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
- CNR - IPCF, Istituto per i Processi Chimico-Fisici, Messina, Italy
- Co-first authors
| | - Judith S Birkenfeld
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
- Co-first authors
| | - Andrés de la Hoz
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
| | - Andrea Curatolo
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
- International Centre for Translational Eye Research, Warsaw, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Warsaw, Poland
| | - James A Germann
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
| | - Lupe Villegas
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
| | - Alejandra Varea
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
| | - Eduardo Martínez-Enríquez
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
| | - Susana Marcos
- Instituto de Óptica "Daza de Valdés", Consejo Superior de Investigaciones Científicas (IO-CSIC), Madrid, Spain
- Center for Visual Science, The Institute of Optics, Flaum Eye Institute, University of Rochester, NY 14642, USA
| |
Collapse
|
18
|
Qiao X, Chen D, Huo H, Tang M, Tang Z, Dong Y, Liu X, Fan Y. Full-field strain mapping for characterization of structure-related variation in corneal biomechanical properties using digital image correlation (DIC) technology. MEDICINE IN NOVEL TECHNOLOGY AND DEVICES 2021. [DOI: 10.1016/j.medntd.2021.100086] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
19
|
|
20
|
Influence of the eye globe design on biomechanical analysis. Comput Biol Med 2021; 135:104612. [PMID: 34261005 DOI: 10.1016/j.compbiomed.2021.104612] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 06/11/2021] [Accepted: 06/23/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE To assess the mechanical contribution of inner eye components on corneal deformation during a finite element analysis. METHODS A finite element model of an eye globe was implemented to examine the corneal response under various mechanical conditions. The model incorporates the cornea, limbus, sclera, iris, lens, muscles, anterior chamber and vitreous. The Ogden hyperelastic model was used for the corneo-limbal region and the Yeoh isotropic model for the sclera. The anterior chamber was modelled as a cavity and other eye components were incorporated as linear elastic material. A fluid dynamic simulation was implemented to determine the spatial air puff velocity and pressure profiles around corneal surface. RESULTS The maximal apical displacement under IOP = 15 mmHg was 0.22 mm with a stress of 0.013 MPa. An unrestrained limbus slightly increases the apical displacement, while an unrestrained equatorial sclera largely increases the displacement by 10%, resulting in reduced stiffness. The iris slightly decreases the displacement but increases stress in the corneal periphery. Meanwhile, the joint contribution of muscle and lens cannot be neglected as it reduces corneal displacement by 50%. Incorporation of the remaining eye components results in nearly similar results. Under air puff loading, a free equatorial sclera raised the dynamic deformation amplitude by nearly 2%, while the dynamic profile remained similar for all remaining study cases considered. CONCLUSION In a finite element analysis, the lens, iris, and muscle each provide major mechanical contributions to corneal deformation, and it is highly recommended that the internal contributions are considered.
Collapse
|
21
|
Wilson A, Jones J, Marshall J. Interferometric Ex Vivo Evaluation of the Spatial Changes to Corneal Biomechanics Introduced by Topographic CXL: A Pilot Study. J Refract Surg 2021; 37:263-273. [PMID: 34038664 DOI: 10.3928/1081597x-20210203-01] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
PURPOSE To determine the efficacy of interferometry for examining the spatial changes to the corneal biomechanical response to simulated intraocular pressure (IOP) fluctuations that occur after corneal cross-linking (CXL) applied in different topographic locations. METHODS Displacement speckle pattern interferometry (DSPI) was used to measure the total anterior surface displacement of human and porcine corneas in response to pressure variations up to 1 mm Hg from a baseline pressure of 16.5 mm Hg, both before and after CXL treatment, which was applied in isolated topographic locations (10-minute riboflavin soak [VibeX-Xtra; Avedro, Inc], 8-minute ultraviolet-A exposure at 15 mW/cm2). Alterations to biomechanics were evaluated by directly comparing the responses before and after treatment for each cornea. RESULTS Before CXL, the corneal response to loading indicated spatial variability in mechanical properties. CXL treatments had a variable effect on the corneal response to loading dependent on the location of treatment, with reductions in regional displacement of up to 80% in response to a given pressure increase. CONCLUSIONS Selectively cross-linking in different topographic locations introduces position-specific changes to mechanical properties that could potentially be used to alter the refractive power of the cornea. Changes to the biomechanics of the cornea after CXL are complex and appear to vary significantly depending on treatment location and initial biomechanics. Hence, further investigations are required on a larger number of corneas to allow the development of customized treatment protocols. In this study, laser interferometry was demonstrated to be an effective and valuable tool to achieve this. [J Refract Surg. 2021;37(4):263-273.].
Collapse
|
22
|
Wilson A, Marshall J. A review of corneal biomechanics: Mechanisms for measurement and the implications for refractive surgery. Indian J Ophthalmol 2021; 68:2679-2690. [PMID: 33229643 PMCID: PMC7856929 DOI: 10.4103/ijo.ijo_2146_20] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Detailed clinical assessment of corneal biomechanics has the potential to revolutionize the ophthalmic industry through enabling quicker and more proficient diagnosis of corneal disease, safer and more effective surgical treatments, and the provision of customized and optimized care. Despite these wide-ranging benefits, and an outstanding clinical need, the provision of technology capable of the assessment of corneal biomechanics in the clinic is still in its infancy. While laboratory-based technologies have progressed significantly over the past decade, there remain significant gaps in our knowledge regarding corneal biomechanics and how they relate to shape and function, and how they change in disease and after surgical intervention. Here, we discuss the importance, relevance, and challenges associated with the assessment of corneal biomechanics and review the techniques currently available and underdevelopment in both the laboratory and the clinic.
Collapse
Affiliation(s)
- Abby Wilson
- Wolfson School of Mechanical, Manufacturing and Electrical Engineering, Loughborough University, Loughborough, UK
| | - John Marshall
- Wolfson School of Mechanical, Manufacturing and Electrical Engineering, Loughborough University, Loughborough, UK
| |
Collapse
|
23
|
Chong J, Dupps WJ. Corneal biomechanics: Measurement and structural correlations. Exp Eye Res 2021; 205:108508. [PMID: 33609511 DOI: 10.1016/j.exer.2021.108508] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 02/09/2021] [Accepted: 02/12/2021] [Indexed: 02/02/2023]
Abstract
The characterization of corneal biomechanical properties has important implications for the management of ocular disease and prediction of surgical responses. Corneal refractive surgery outcomes, progression or stabilization of ectatic disease, and intraocular pressure determination are just examples of the many key clinical problems that depend highly upon corneal biomechanical characteristics. However, to date there is no gold standard measurement technique. Since the advent of a 1-dimensional (1D) air-puff based technique for measuring the corneal surface response in 2005, advances in clinical imaging technology have yielded increasingly sophisticated approaches to characterizing the biomechanical properties of the cornea. Novel analyses of 1D responses are expanding the clinical utility of commercially-available air-puff-based instruments, and other imaging modalities-including optical coherence elastography (OCE), Brillouin microscopy and phase-decorrelation ocular coherence tomography (PhD-OCT)-offer new opportunities for probing local biomechanical behavior in 3-dimensional space and drawing new inferences about the relationships between corneal structure, mechanical behavior, and corneal refractive function. These advances are likely to drive greater clinical adoption of in vivo biomechanical analysis and to support more personalized medical and surgical decision-making.
Collapse
Affiliation(s)
- Jillian Chong
- Cleveland Clinic Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA
| | - William J Dupps
- Cleveland Clinic Cole Eye Institute, Cleveland Clinic, Cleveland, OH, USA; Dept. of Ophthalmology, Cleveland Clinic Lerner College of Medicine of Case Western Reserve Univ, Cleveland, OH, USA; Dept. of Biomedical Engineering, Lerner Research Institute and Case Western Reserve Univ, Cleveland, OH, USA.
| |
Collapse
|
24
|
Aboulatta A, Abass A, Makarem A, Eliasy A, Zhou D, Chen D, Liu X, Elsheikh A. Experimental evaluation of the viscoelasticity of porcine vitreous. J R Soc Interface 2021; 18:20200849. [PMID: 33530856 DOI: 10.1098/rsif.2020.0849] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
This study aims to estimate the material properties of the porcine vitreous while testing it in close to its natural physiological conditions. Eighteen porcine eyes were tested within 48 h post-mortem. A custom-built computer-controlled test rig was designed to support, load and monitor the behaviour of eye globes while being subjected to dynamic rotation cycles mimicking saccade eye movement. Specimens were glued to the base of a container, surrounded by gelatin, frozen and cut in half to expose the vitreous. After thawing, the container was subjected to concentric dynamic rotations of up to 5°, 10° or 15°, while taking 50 MP photos of the specimen every 2 ms. The images were analysed by a digital image correlation algorithm to trace the movement of marked points on the vitreous surface with different radii from the centre of the posterior chamber. The initial camera image was used in building a finite-element model of the test set-up, which was used in an inverse analysis exercise to estimate the material properties of the vitreous. Angular displacements of the monitored points were up to 3.3°, 4.1° and 3.9° in response to eye rotations of 5°, 10° and 15°, respectively. With the experimental relationships between eye rotation and angular displacements used as target behaviour, the inverse analysis exercise estimated the initial shear modulus, the long-term shear modulus and the viscoelastic decay constant of the porcine vitreous as 2.10 ± 0.15 Pa, 0.50 ± 0.04 Pa and 1.20 ± 0.09 s-1, respectively. Consideration of the viscoelasticity of the vitreous was essential to represent its experimental behaviour. Testing the vitreous in close to its normal physiological conditions produced estimations of the initial shear modulus and long-term shear modulus that were, respectively, smaller and larger than reported values (Zimberlin et al. 2010 Soft Matter 6, 3632-3635. (doi:10.1039/b925407b), Liu et al. 2013 J. Biomech. 46, 1321-7. (doi:10.1016/j.jbiomech.2013.02.006), Rossi et al. 2011 Invest. Ophthalmol. Vis. Sci. 52, 3994-4002. (doi:10.1167/iovs.10-6477)).
Collapse
Affiliation(s)
- Ali Aboulatta
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Ahmed Abass
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Ahmed Makarem
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Dong Zhou
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK
| | - Duo Chen
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, People's Republic of China
| | - Xiaoyu Liu
- Key Laboratory for Biomechanics and Mechanobiology of the Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, People's Republic of China.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 100083, People's Republic of China
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool L69 3GH, UK.,Beijing Advanced Innovation Centre for Biomedical Engineering, Beihang University, Beijing 100083, People's Republic of China.,NIHR Biomedical Research Centre for Ophthalmology, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK
| |
Collapse
|
25
|
Chang SH, Zhou D, Eliasy A, Li YC, Elsheikh A. Experimental evaluation of stiffening effect induced by UVA/Riboflavin corneal cross-linking using intact porcine eye globes. PLoS One 2020; 15:e0240724. [PMID: 33147249 PMCID: PMC7641398 DOI: 10.1371/journal.pone.0240724] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2020] [Accepted: 10/02/2020] [Indexed: 11/24/2022] Open
Abstract
UVA/riboflavin corneal cross-linking (CXL) is a common used approach to treat progressive keratoconus. This study aims to investigate the alteration of corneal stiffness following CXL by mimicking the inflation of the eye under the in vivo loading conditions. Seven paired porcine eye globes were involved in the inflation test to examine the corneal behaviour. Cornea-only model was constructed using the finite element method, without considering the deformation contribution from sclera and limbus. Inverse analysis was conducted to calibrate the non-linear material behaviours in order to reproduce the inflation test. The corneal stress and strain values were then extracted from the finite element models and tangent modulus was calculated under stress level at 0.03 MPa. UVA/riboflavin cross-linked corneas displayed a significant increase in the material stiffness. At the IOP of 27.25 mmHg, the average displacements of corneal apex were 307 ± 65 μm and 437 ± 63 μm (p = 0.02) in CXL and PBS corneas, respectively. Comparisons performed on tangent modulus ratios at a stress of 0.03 MPa, the tangent modulus measured in the corneas treated with the CXL was 2.48 ± 0.69, with a 43±24% increase comparing to its PBS control. The data supported that corneal material properties can be well-described using this inflation methods following CXL. The inflation test is valuable for investigating the mechanical response of the intact human cornea within physiological IOP ranges, providing benchmarks against which the numerical developments can be translated to clinic.
Collapse
Affiliation(s)
- Shao-Hsuan Chang
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
- Department of Chemical Engineering, Feng Chia University, Taichung, Taiwan
- * E-mail: (LYC); (CSH)
| | - Dong Zhou
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
| | - Ashkan Eliasy
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
| | - Yi-Chen Li
- Department of Chemical Engineering, Feng Chia University, Taichung, Taiwan
- * E-mail: (LYC); (CSH)
| | - Ahmed Elsheikh
- School of Engineering, University of Liverpool, Liverpool, United Kingdom
| |
Collapse
|
26
|
Ma Y, Kwok S, Sun J, Pan X, Pavlatos E, Clayson K, Hazen N, Liu J. IOP-induced regional displacements in the optic nerve head and correlation with peripapillary sclera thickness. Exp Eye Res 2020; 200:108202. [PMID: 32861767 PMCID: PMC7655654 DOI: 10.1016/j.exer.2020.108202] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 08/13/2020] [Accepted: 08/25/2020] [Indexed: 12/30/2022]
Abstract
Mechanical insult induced by intraocular pressure (IOP) is likely a driving force in the disease process of glaucoma. This study aimed to evaluate regional displacements in human optic nerve head (ONH) and peripapillary tissue (PPT) in response to acute IOP elevations, and their correlations with morphological characteristics of the posterior eye. Cross-sectional (2D) images of the ONH and PPT in 14 globes of 14 human donors were acquired with high-frequency ultrasound during whole globe inflation from 5 to 30 mm Hg. High-frequency ultrasound has a spatial resolution of tens of micrometers and is capable of imaging through the ONH and PPT thickness. Tissue displacements were calculated using a correlation-based speckle tracking algorithm for a dense matrix of kernels covering the 2D imaging plane. The ONH was manually segmented in the ultrasound B-mode images acquired at 5 mmHg based on echogenicity. The lamina cribrosa (LC) boundaries were visible in eight of the fourteen eyes and the LC region was segmented using a semi-automated superpixel-based method. The ONH had larger radial displacement than the PPT in all tested eyes and the difference increased with increasing IOP. A significant negative correlation was found between ONH-PPT displacement difference and PPT thickness (p < 0.05), while no significant correlations were found between ONH-PPT displacement difference and other morphological parameters including PPT radius of curvature, scleral canal size, LC thickness and anterior LC surface depth. Within the ONH, the radial displacement decreased in the region anterior to and across LC but not in the region posterior to LC. Finite element models using simplified geometry and material properties confirmed the role of LC in reducing the overall ONH radial displacements, but did not predict the displacement gradient change observed experimentally. These results suggested that a thinner PPT may be associated with a larger relative posterior motion of the ONH with respect to the surrounding PPT and the LC may play a major role in preventing excessive posterior displacement of ONH during acute IOP elevations.
Collapse
Affiliation(s)
- Yanhui Ma
- Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA
| | - Sunny Kwok
- Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA
| | - Jiajun Sun
- Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA
| | - Xueliang Pan
- Department of Biomedical Informatics, Ohio State University, Columbus, OH, USA
| | - Elias Pavlatos
- Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA
| | - Keyton Clayson
- Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA; Biophysics Interdisciplinary Group, Ohio State University, Columbus, OH, USA
| | - Nicholas Hazen
- Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA; Biophysics Interdisciplinary Group, Ohio State University, Columbus, OH, USA
| | - Jun Liu
- Department of Biomedical Engineering, Ohio State University, Columbus, OH, USA; Biophysics Interdisciplinary Group, Ohio State University, Columbus, OH, USA; Department of Ophthalmology and Visual Science, Ohio State University, Columbus, OH, USA.
| |
Collapse
|
27
|
Wang B, Hua Y, Brazile BL, Yang B, Sigal IA. Collagen fiber interweaving is central to sclera stiffness. Acta Biomater 2020; 113:429-437. [PMID: 32585309 DOI: 10.1016/j.actbio.2020.06.026] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2020] [Revised: 06/01/2020] [Accepted: 06/15/2020] [Indexed: 12/27/2022]
Abstract
The mechanical properties of the microstructural components of sclera are central to eye physiology and pathology. Because these parameters are extremely difficult to measure directly, they are often estimated using inverse-modeling matching deformations of macroscopic samples measured experimentally. Although studies of sclera microstructure show collagen fiber interweaving, current models do not account for this interweaving or the resulting fiber-fiber interactions, which might affect parameter estimates. Our goal was to test the hypothesis that constitutive parameters estimated using inverse modeling differ if models account for fiber interweaving and interactions. We developed models with non-interweaving or interweaving fibers over a wide range of volume fractions (36-91%). For each model, we estimated fiber stiffness using inverse modeling matching biaxial experimental data of human sclera. We found that interweaving increased the estimated fiber stiffness. When the collagen volume fraction was 64% or less, the stiffness of interweaving fibers was about 1.25 times that of non-interweaving fibers. For higher volume fractions, the ratio increased substantially, reaching 1.88 for a collagen volume fraction of 91%. Simulating a model (interweaving/non-interweaving) using the fiber stiffness estimated from the other model produced substantially different behavior, far from that observed experimentally. These results show that estimating microstructural component mechanical properties is highly sensitive to the assumed interwoven/non-interwoven architecture. Moreover, the results suggest that interweaving plays an important role in determining the structural stiffness of sclera, and potentially of other soft tissues in which the collagen fibers interweave. STATEMENT OF SIGNIFICANCE: The collagen fibers of sclera are interwoven, but numerical models do not account for this interweaving or the resulting fiber-fiber interactions. To determine if interweaving matters, we examined the differences in the constitutive model parameters estimated using inverse modeling between models with interweaving and non-interweaving fibers. We found that the estimated stiffness of the interweaving fibers was up to 1.88 times that of non-interweaving fibers, and that the estimate increased with collagen volume fraction. Our results suggest that fiber interweaving is a fundamental characteristic of connective tissues, additional to anisotropy, density and orientation. Better characterization of interweaving, and of its mechanical effects is likely central to understanding microstructure and biomechanics of sclera and other soft tissues.
Collapse
|
28
|
Wilson A, Jones J, Tyrer JR, Marshall J. An interferometric ex vivo study of corneal biomechanics under physiologically representative loading, highlighting the role of the limbus in pressure compensation. EYE AND VISION 2020; 7:43. [PMID: 32832574 PMCID: PMC7433364 DOI: 10.1186/s40662-020-00207-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Accepted: 07/25/2020] [Indexed: 12/23/2022]
Abstract
Background The mechanical properties of the cornea are complex and regionally variable. This paper uses an original method to investigate the biomechanics of the cornea in response to hydrostatic loading over the typical physiological range of intra-ocular pressure (IOP) fluctuations thereby increasing understanding of clinically relevant corneal biomechanical properties and their contributions to the refractive properties of the cornea. Methods Displacement speckle pattern interferometry (DSPI) was used to measure the total surface displacement of 40 porcine and 6 human corneal-scleral specimens in response to pressure variations up to 1 mmHg from a baseline of 16.5 mmHg. All specimens were mounted in a modified artificial anterior chamber (AAC) and loaded hydrostatically. Areas of high strain in response to loading were identified by comparing the displacements across different regions. Results The nature of the response of the corneal surface to loading demonstrated high regional topographic variation. Mechanical properties were shown to be asymmetrical, and deformation of the limbal and pre-limbal regions dominated these responses respectively with over 90% (N-T) and 60% (S-I) of the total maximum displacement occurring in these regions indicating high-strain. In contrast, the curvature of the central cornea remained relatively unchanged merely translating in position. Conclusions The limbal and pre-limbal regions of the cornea appear to be fundamental to the absorption of small pressure fluctuations facilitating the curvature of the central cornea to remain relatively unchanged. The differential mechanical properties of this region could have important implications for the application of corneal surgery and corneal crosslinking, warranting further investigation.
Collapse
Affiliation(s)
- Abby Wilson
- Wolfson School of Mechanical, Manufacturing and Electrical Engineering, Loughborough University, Loughborough, UK
| | - John Jones
- Laser Optical Engineering Ltd., Derbyshire, UK
| | - John R Tyrer
- Wolfson School of Mechanical, Manufacturing and Electrical Engineering, Loughborough University, Loughborough, UK.,Laser Optical Engineering Ltd., Derbyshire, UK
| | | |
Collapse
|
29
|
Kazaili A, Geraghty B, Akhtar R. Microscale assessment of corneal viscoelastic properties under physiological pressures. J Mech Behav Biomed Mater 2019; 100:103375. [DOI: 10.1016/j.jmbbm.2019.103375] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Revised: 07/21/2019] [Accepted: 07/26/2019] [Indexed: 10/26/2022]
|
30
|
Boote C, Sigal IA, Grytz R, Hua Y, Nguyen TD, Girard MJA. Scleral structure and biomechanics. Prog Retin Eye Res 2019; 74:100773. [PMID: 31412277 DOI: 10.1016/j.preteyeres.2019.100773] [Citation(s) in RCA: 139] [Impact Index Per Article: 27.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 08/07/2019] [Accepted: 08/08/2019] [Indexed: 12/18/2022]
Abstract
As the eye's main load-bearing connective tissue, the sclera is centrally important to vision. In addition to cooperatively maintaining refractive status with the cornea, the sclera must also provide stable mechanical support to vulnerable internal ocular structures such as the retina and optic nerve head. Moreover, it must achieve this under complex, dynamic loading conditions imposed by eye movements and fluid pressures. Recent years have seen significant advances in our knowledge of scleral biomechanics, its modulation with ageing and disease, and their relationship to the hierarchical structure of the collagen-rich scleral extracellular matrix (ECM) and its resident cells. This review focuses on notable recent structural and biomechanical studies, setting their findings in the context of the wider scleral literature. It reviews recent progress in the development of scattering and bioimaging methods to resolve scleral ECM structure at multiple scales. In vivo and ex vivo experimental methods to characterise scleral biomechanics are explored, along with computational techniques that combine structural and biomechanical data to simulate ocular behaviour and extract tissue material properties. Studies into alterations of scleral structure and biomechanics in myopia and glaucoma are presented, and their results reconciled with associated findings on changes in the ageing eye. Finally, new developments in scleral surgery and emerging minimally invasive therapies are highlighted that could offer new hope in the fight against escalating scleral-related vision disorder worldwide.
Collapse
Affiliation(s)
- Craig Boote
- Structural Biophysics Research Group, School of Optometry & Vision Sciences, Cardiff University, UK; Ophthalmic Engineering & Innovation Laboratory (OEIL), Department of Biomedical Engineering, National University of Singapore, Singapore; Newcastle Research & Innovation Institute Singapore (NewRIIS), Singapore.
| | - Ian A Sigal
- Laboratory of Ocular Biomechanics, Department of Ophthalmology, University of Pittsburgh, USA
| | - Rafael Grytz
- Department of Ophthalmology & Visual Sciences, University of Alabama at Birmingham, USA
| | - Yi Hua
- Laboratory of Ocular Biomechanics, Department of Ophthalmology, University of Pittsburgh, USA
| | - Thao D Nguyen
- Department of Mechanical Engineering, Johns Hopkins University, USA
| | - Michael J A Girard
- Ophthalmic Engineering & Innovation Laboratory (OEIL), Department of Biomedical Engineering, National University of Singapore, Singapore; Singapore Eye Research Institute (SERI), Singapore National Eye Centre, Singapore
| |
Collapse
|
31
|
Kazaili A, Lawman S, Geraghty B, Eliasy A, Zheng Y, Shen Y, Akhtar R. Line-Field Optical Coherence Tomography as a tool for In vitro characterization of corneal biomechanics under physiological pressures. Sci Rep 2019; 9:6321. [PMID: 31004101 PMCID: PMC6474860 DOI: 10.1038/s41598-019-42789-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 04/03/2019] [Indexed: 12/02/2022] Open
Abstract
There has been a lot of interest in accurately characterising corneal biomechanical properties under intraocular pressure (IOP) to help better understand ocular pathologies that are associated with elevated IOP. This study investigates the novel use of Line-Field Optical Coherence Tomography (LF-OCT) as an elastographic tool for accurately measuring mechanical properties of porcine corneas based on volumetric deformation following varying IOPs. A custom-built LF-OCT was used to measure geometrical and corneal surface displacement changes in porcine corneas under a range of IOPs, from 0-60 mmHg. Corneal thickness, elastic properties and hysteresis were calculated as a function of pressure. In addition, the effects of hydration were explored. We found that the elastic modulus increased in a linear fashion with IOP. Corneal thickness was found to reduce with IOP, decreasing 14% from 0 to 60 mmHg. Prolonged hydration in phosphate buffered saline (PBS) was found to significantly increase the elastic modulus and corneal hysteresis. Our study demonstrates that LF-OCT can be used to accurately measure the elastic properties based on volumetric deformation following physiological pressures. Furthermore, we show that prolonged hydration in PBS has a significant effect on the measured corneal properties.
Collapse
Affiliation(s)
- Ahmed Kazaili
- Department of Mechanical, Materials and Aerospace Engineering, School of Engineering, University of Liverpool, Liverpool, L69 3GH, UK
- Department of Biomedical Engineering, College of Engineering, University of Babylon, Hillah, Iraq
| | - Samuel Lawman
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, UK
- Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, L7 8TX, UK
| | - Brendan Geraghty
- Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, L7 8TX, UK
| | - Ashkan Eliasy
- Department of Mechanical, Materials and Aerospace Engineering, School of Engineering, University of Liverpool, Liverpool, L69 3GH, UK
| | - Yalin Zheng
- Institute of Ageing and Chronic Disease, University of Liverpool, Liverpool, L7 8TX, UK
| | - Yaochun Shen
- Department of Electrical Engineering and Electronics, University of Liverpool, Liverpool, L69 3GJ, UK
| | - Riaz Akhtar
- Department of Mechanical, Materials and Aerospace Engineering, School of Engineering, University of Liverpool, Liverpool, L69 3GH, UK.
| |
Collapse
|
32
|
Tran H, Wallace J, Zhu Z, Lucy KA, Voorhees AP, Schmitt SE, Bilonick RA, Schuman JS, Smith MA, Wollstein G, Sigal IA. Seeing the Hidden Lamina: Effects of Exsanguination on the Optic Nerve Head. Invest Ophthalmol Vis Sci 2019; 59:2564-2575. [PMID: 29847664 PMCID: PMC5968837 DOI: 10.1167/iovs.17-23356] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
Purpose To introduce an experimental approach for direct comparison of the primate optic nerve head (ONH) before and after death by exsanguination. Method The ONHs of four eyes from three monkeys were imaged with spectral-domain optical coherence tomography (OCT) before and after exsanguination under controlled IOP. ONH structures, including the Bruch membrane (BM), BM opening, inner limiting membrane (ILM), and anterior lamina cribrosa (ALC) were delineated on 18 virtual radial sections per OCT scan. Thirteen parameters were analyzed: scleral canal at BM opening (area, planarity, and aspect ratio), ILM depth, BM depth; ALC (depth, shape index, and curvedness), and ALC visibility (globally, superior, inferior, nasal, and temporal quadrants). Results All four ALC quadrants had a statistically significant improvement in visibility after exsanguination (overall P < 0.001). ALC visibility increased by 35% globally and by 36%, 37%, 14%, and 4% in the superior, inferior, nasal, and temporal quadrants, respectively. ALC increased 4.1%, 1.9%, and 0.1% in curvedness, shape index, and depth, respectively. Scleral canals increased 7.2%, 25.2%, and 1.1% in area, planarity, and aspect ratio, respectively. ILM and BM depths averaged -7.5% and -55.2% decreases in depth, respectively. Most, but not all, changes were beyond the repeatability range. Conclusions Exsanguination allows for improved lamina characterization, especially in regions typically blocked by shadowing in OCT. The results also demonstrate changes in ONH morphology due to the loss of blood pressure. Future research will be needed to determine whether there are differences in ONH biomechanics before and after exsanguination and what those differences would imply.
Collapse
Affiliation(s)
- Huong Tran
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States.,Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Jacob Wallace
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Ziyi Zhu
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Katie A Lucy
- New York University Langone Eye Center, NYU School of Medicine, New York, New York, United States
| | - Andrew P Voorhees
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Samantha E Schmitt
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Richard A Bilonick
- Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Joel S Schuman
- New York University Langone Eye Center, NYU School of Medicine, New York, New York, United States
| | - Matthew A Smith
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States.,Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| | - Gadi Wollstein
- New York University Langone Eye Center, NYU School of Medicine, New York, New York, United States
| | - Ian A Sigal
- Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, United States.,Department of Ophthalmology, University of Pittsburgh, Pittsburgh, Pennsylvania, United States
| |
Collapse
|
33
|
Potop V, Corbu C, Coviltir V, Schmitzer S, Constantin M, Burcel M, Ionescu C, Dăscălescu D. The importance of corneal assessment in a glaucoma suspect - a review. Rom J Ophthalmol 2019; 63:321-326. [PMID: 31915729 PMCID: PMC6943289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Glaucoma represents the main cause of irreversible blindness in the world and for this consideration, the interest in a quick and precise diagnosis and progression of the disease, prior to the appearance of irreversible damage, has been continuously rising. Glaucoma risk factors are already well known, but current studies reveal that it is necessary to make a proper analysis of the intraocular pressure (IOP) to obtain an accurate diagnosis, so we must take into consideration corneal properties that might affect IOP measurements. Starting from corneal geometrical properties represented by central corneal thickness (CCT) and continuing with biomechanical properties represented by corneal hysteresis (CH) and corneal resistance factor (CRF) we reviewed the value of investigating corneal properties in ocular hypertension (OH), primary open angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. We can now say that CCT plays an important role in diagnosing glaucoma because it may mask the real value of the IOP and also, in setting the target for the IOP needed to stop disease progression. Also, CH is a factor that needs to be screened from the first consult of a glaucoma patient or suspect because it is correlated to the response to treatment, visual field (VF) and retinal nerve fiber layer (RNFL) progression and could anticipate the future evolution and patients prognosis. Both CCT and CH are factors that must be thought-about when we encounter a glaucoma suspect. CCT has a predictive role in OH and NTG patients, while CH has on the other hand a prognostic role in POAG, OH and NTG patients.
Collapse
Affiliation(s)
- Vasile Potop
- “Carol Davila” University of Medicine and Pharmacy Bucharest, Romania
,Clinical Hospital of Ophthalmologic Emergencies Bucharest, Romania
| | - Cătălina Corbu
- Clinical Hospital of Ophthalmologic Emergencies Bucharest, Romania
| | - Valeria Coviltir
- “Carol Davila” University of Medicine and Pharmacy Bucharest, Romania
,Clinical Hospital of Ophthalmologic Emergencies Bucharest, Romania
| | - Speranţa Schmitzer
- “Carol Davila” University of Medicine and Pharmacy Bucharest, Romania
,Clinical Hospital of Ophthalmologic Emergencies Bucharest, Romania
| | | | | | | | - Dana Dăscălescu
- “Carol Davila” University of Medicine and Pharmacy Bucharest, Romania
,Oftaclinic Bucharest, Romania
| |
Collapse
|
34
|
Jan NJ, Brazile BL, Hu D, Grube G, Wallace J, Gogola A, Sigal IA. Crimp around the globe; patterns of collagen crimp across the corneoscleral shell. Exp Eye Res 2018; 172:159-170. [PMID: 29660327 DOI: 10.1016/j.exer.2018.04.003] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Revised: 04/05/2018] [Accepted: 04/09/2018] [Indexed: 12/20/2022]
Abstract
Our goal was to systematically quantify the collagen crimp morphology around the corneoscleral shell, and test the hypothesis that collagen crimp is not uniform over the globe. Axial longitudinal cryosections (30 μm) of three sheep eyes, fixed at 0 mmHg IOP, were imaged using polarized light microscopy to quantify the local collagen in 8 regions: two corneal (central and peripheral) and six scleral (limbus, anterior-equatorial, equatorial, posterior-equatorial, posterior and peripapillary). Collagen crimp period (length of one wave), tortuosity (path length divided by end-to-end length), waviness (SD of orientation), amplitude (half the peak to trough distance), and conformity (width of contiguous similarly oriented bundles) were measured in each region. Measurements were obtained on 8216 collagen fiber bundles. When pooling measurements across the whole eye globe, the median crimp values were: 23.9 μm period, 13.2 μm conformity, 0.63 μm amplitude, 1.006 tortuosity, and 12.7° waviness. However, all parameters varied significantly across the globe. Median bundle periods in the central cornea, limbus, and peripapillary sclera (PPS) were 14.1 μm, 29.5 μm, and 22.9 μm, respectively. Median conformities were 20.8 μm, 14.5 μm, and 15.1 μm, respectively. Median tortuosities were 1.005, 1.007, and 1.007, respectively. Median waviness' were 11.4°, 13.2°, and 13.2°, respectively. Median amplitudes were 0.35 μm, 0.87 μm, and 0.65 μm, respectively. All parameters varied significantly across the globe. All regions differed significantly from one another on at least one parameter. Regions with small periods had large conformities, and bundles with high tortuosity had high waviness and amplitude. Waviness, tortuosity, and amplitude, associated with nonlinear biomechanical behavior, exhibited "double hump" distributions, whereas period and conformity, representing tissue organization, were substantially different between sclera and cornea. Though the biomechanical implications and origin of the patterns observed remain unclear, our findings of well-defined patterns of collagen crimp across the corneoscleral shell, consistent between eyes, support the existence of mechanisms that regulate collagen characteristics at the regional or smaller levels. These results are experimental data necessary for more realistic models of ocular biomechanics and remodeling.
Collapse
Affiliation(s)
- Ning-Jiun Jan
- Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, USA; Department of Ophthalmology, University of Pittsburgh School of Medicine, USA
| | - Bryn L Brazile
- Department of Ophthalmology, University of Pittsburgh School of Medicine, USA
| | - Danielle Hu
- Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, USA; Department of Ophthalmology, University of Pittsburgh School of Medicine, USA
| | - Garrett Grube
- Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, USA
| | - Jacob Wallace
- Department of Ophthalmology, University of Pittsburgh School of Medicine, USA
| | - Alexandra Gogola
- Department of Ophthalmology, University of Pittsburgh School of Medicine, USA
| | - Ian A Sigal
- Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, USA; Department of Ophthalmology, University of Pittsburgh School of Medicine, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh School of Medicine and University of Pittsburgh, USA; The Louis J. Fox Center for Vision Restoration of UPMC and the University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
35
|
Corneal Vibrations during Intraocular Pressure Measurement with an Air-Puff Method. JOURNAL OF HEALTHCARE ENGINEERING 2018; 2018:5705749. [PMID: 29610655 PMCID: PMC5828335 DOI: 10.1155/2018/5705749] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 10/25/2017] [Accepted: 12/11/2017] [Indexed: 12/19/2022]
Abstract
Introduction The paper presents a commentary on the method of analysis of corneal vibrations occurring during eye pressure measurements with air-puff tonometers, for example, Corvis. The presented definition and measurement method allow for the analysis of image sequences of eye responses—cornea deformation. In particular, the outer corneal contour and sclera fragments are analysed, and 3D reconstruction is performed. Methods On this basis, well-known parameters such as eyeball reaction or corneal response are determined. The next steps of analysis allow for automatic and reproducible separation of four different corneal vibrations. These vibrations are associated with (1) the location of the maximum of cornea deformation; (2) the cutoff area measured in relation to the cornea in a steady state; (3) the maximum of peaks occurring between applanations; and (4) the other characteristic points of the corneal contour. Results The results obtained enable (1) automatic determination of the amplitude of vibrations; (2) determination of the frequency of vibrations; and (3) determination of the correlation between the selected types of vibrations. Conclusions These are diagnostic features that can be directly applied clinically for new and archived data.
Collapse
|
36
|
The hierarchical response of human corneal collagen to load. Acta Biomater 2018; 65:216-225. [PMID: 29128531 PMCID: PMC5729024 DOI: 10.1016/j.actbio.2017.11.015] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Revised: 11/05/2017] [Accepted: 11/07/2017] [Indexed: 02/04/2023]
Abstract
Fibrillar collagen in the human cornea is integral to its function as a transparent lens of precise curvature, and its arrangement is now well-characterised in the literature. While there has been considerable effort to incorporate fibrillar architecture into mechanical models of the cornea, the mechanical response of corneal collagen to small applied loads is not well understood. In this study the fibrillar and molecular response to tensile load was quantified using small and wide angle X-ray scattering (SAXS/WAXS), and digital image correlation (DIC) photography was used to calculate the local strain field that gave rise to the hierarchical changes. A molecular scattering model was used to calculate the tropocollagen tilt relative to the fibril axis and changes associated with applied strain. Changes were measured in the D-period, molecular tilt and the orientation and spacing of the fibrillar and molecular networks. These measurements were summarised into hierarchical deformation mechanisms, which were found to contribute at varying strains. The change in molecular tilt is indicative of a sub-fibrillar “spring-like” deformation mechanism, which was found to account for most of the applied strain under physiological and near-physiological loads. This deformation mechanism may play an important functional role in tissues rich in fibrils of high helical tilt, such as skin and cartilage. Statement of Significance Collagen is the primary mediator of soft tissue biomechanics, and variations in its hierarchical structure convey the varying amounts of structural support necessary for organs to function normally. Here we have examined the structural response of corneal collagen to tensile load using X-rays to probe hierarchies ranging from molecular to fibrillar. We found a previously unreported deformation mechanism whereby molecules, which are helically arranged relative to the axis of their fibril, change in tilt akin to the manner in which a spring stretches. This “spring-like” mechanism accounts for a significant portion of the applied deformation at low strains (<3%). These findings will inform the future design of collagen-based artificial corneas being developed to address world-wide shortages of corneal donor tissue.
Collapse
|
37
|
Biomechanical Simulation of Stress Concentration and Intraocular Pressure in Corneas Subjected to Myopic Refractive Surgical Procedures. Sci Rep 2017; 7:13906. [PMID: 29066773 PMCID: PMC5655007 DOI: 10.1038/s41598-017-14293-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Accepted: 10/05/2017] [Indexed: 11/14/2022] Open
Abstract
Recent advances in the analysis of corneal biomechanical properties remain difficult to predict the structural stability before and after refractive surgery. In this regard, we applied the finite element method (FEM) to determine the roles of the Bowman’s membrane, stroma, and Descemet’s membrane in the hoop stresses of cornea, under tension (physiological) and bending (nonphysiological), for patients who undergo radial keratotomy (RK), photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis (LASIK), or small incision lenticule extraction (SMILE). The stress concentration maps, potential creak zones, and potential errors in intraocular pressure (IOP) measurements were further determined. Our results confirmed that the Bowman’s membrane and Descemet’s membrane accounted for 20% of the bending rigidity of the cornea, and became the force pair dominating the bending behaviour of the cornea, the high stress in the distribution map, and a stretch to avoid structural failure. In addition, PRK broke the central linking of hoop stresses and concentrated stress on the edge of the Bowman’s membrane around ablation, which posed considerable risk of potential creaks. Compared with SMILE, LASIK had a higher risk of developing creaks around the ablation in the stroma layer. Our FEM models also predicted the postoperative IOPs precisely in a conditional manner.
Collapse
|
38
|
Madni A, Rahem MA, Tahir N, Sarfraz M, Jabar A, Rehman M, Kashif PM, Badshah SF, Khan KU, Santos HA. Non-invasive strategies for targeting the posterior segment of eye. Int J Pharm 2017; 530:326-345. [PMID: 28755994 DOI: 10.1016/j.ijpharm.2017.07.065] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Revised: 07/20/2017] [Accepted: 07/21/2017] [Indexed: 01/02/2023]
Abstract
The safe and effective treatment of eye diseases has been remained a global myth. Several advancements have been done and various drug delivery and treatment techniques have been suggested. The Posterior segment disorders are the leading cause of visual impairments and blindness. Targeting the therapeutic agents to the anterior and posterior segments of the eye has attracted extensive attention from the scientific community. Significant key factors in the success of ocular therapy are the development of safe, effective, economic and non-invasive novel drug delivery systems. These specialized non-invasive ocular drug delivery systems revolutionized the drug delivery strategies by overcoming the limitations, provided targeted delivery to the ocular tissues by avoiding larger doses, and reducing the toxicity encountered by the conventional approaches. These non-invasive systems are fabricated by ingredients encompassing biodegradability, biocompatibility, mucoadhesion, solubility and permeability enhancement and stimuli responsiveness. The variety of routes are utilized to provide minimally invasive drug delivery to the patients without any discomfort and pain. This review is focused on the brief introduction, types, significance, preparation techniques, components and mechanism of drug release of non-invasive systems, including in situ gelling systems, microspheres, iontophoresis, nanoparticles, nanosuspensions and specialized novel emulsions.
Collapse
Affiliation(s)
- Asadullah Madni
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan.
| | - Muhammad Abdur Rahem
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan
| | - Nayab Tahir
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan; Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, FI-00014 Helsinki, Finland
| | - Muhammad Sarfraz
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan
| | - Abdul Jabar
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan
| | - Mubashar Rehman
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan
| | - Prince Muhammad Kashif
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan
| | - Syed Faisal Badshah
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan
| | - Kifayat Ullah Khan
- Department of Pharmacy, The Islamia University of Bahawalpur, 63100 Bahawalpur, Pakistan
| | - Hélder A Santos
- Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, FI-00014 Helsinki, Finland; Helsinki Institute of Life Science (HiLIFE), University of Helsinki, FI-00014 Helsinki, Finland.
| |
Collapse
|
39
|
Rogala MM, Danielewska ME, Antończyk A, Kiełbowicz Z, Rogowska ME, Kozuń M, Detyna J, Iskander DR. In-vivo corneal pulsation in relation to in-vivo intraocular pressure and corneal biomechanics assessed in-vitro. An animal pilot study. Exp Eye Res 2017; 162:27-36. [PMID: 28689748 DOI: 10.1016/j.exer.2017.07.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2016] [Revised: 06/30/2017] [Accepted: 07/05/2017] [Indexed: 01/27/2023]
Abstract
The aim was to ascertain whether the characteristics of the corneal pulse (CP) measured in-vivo in a rabbit eye change after short-term artificial increase of intraocular pressure (IOP) and whether they correlate with corneal biomechanics assessed in-vitro. Eight New Zealand white rabbits were included in this study and were anesthetized. In-vivo experiments included simultaneous measurements of the CP signal, registered with a non-contact method, IOP, intra-arterial blood pressure, and blood pulse (BPL), at the baseline and short-term elevated IOP. Afterwards, thickness of post-mortem corneas was determined and then uniaxial tensile tests were conducted leading to estimates of their Young's modulus (E). At the baseline IOP, backward stepwise regression analyses were performed in which successively the ocular biomechanical, biometric and cardiovascular predictors were separately taken into account. Results of the analysis revealed that the 3rd CP harmonic can be statistically significantly predicted by E and central corneal thickness (Models: R2 = 0.662, p < 0.005 and R2 = 0.832, p < 0.001 for the signal amplitude and power, respectively). The 1st CP harmonic can be statistically significantly predicted by the amplitude and power of the 1st BPL harmonic (Models: R2 = 0.534, p = 0.015 and R2 = 0.509, p < 0.018, respectively). For elevated IOP, non-parametric analysis indicated significant differences for the power of the 1st CP harmonic (Kruskal-Wallis test; p = 0.031) and for the mean, systolic and diastolic blood pressures (p = 0.025, p = 0.019, p = 0.033, respectively). In conclusion, for the first time, the association between parameters of the CP signal in-vivo and corneal biomechanics in-vitro was confirmed. In particular, spectral analysis revealed that higher amplitude and power of the 3rd CP harmonic indicates higher corneal stiffness, while the 1st CP harmonic correlates positively with the corresponding harmonic of the BPL signal.
Collapse
Affiliation(s)
- Maja M Rogala
- Wroclaw University of Science and Technology, Department of Mechanics, Materials Science and Engineering, Faculty of Mechanical Engineering, ul. Smoluchowskiego 25, 50-370 Wroclaw, Poland.
| | - Monika E Danielewska
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.
| | - Agnieszka Antończyk
- Wroclaw University of Environmental and Life Sciences, Department of Surgery, Faculty of Veterinary Medicine, pl. Grunwaldzki 51, 50-366 Wroclaw, Poland.
| | - Zdzisław Kiełbowicz
- Wroclaw University of Environmental and Life Sciences, Department of Surgery, Faculty of Veterinary Medicine, pl. Grunwaldzki 51, 50-366 Wroclaw, Poland.
| | - Marta E Rogowska
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.
| | - Marta Kozuń
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Mechatronics and Theory of Mechanisms, Faculty of Mechanical Engineering, ul. Lukasiewicza 7/9, 50-371 Wroclaw, Poland.
| | - Jerzy Detyna
- Wroclaw University of Science and Technology, Department of Mechanics, Materials Science and Engineering, Faculty of Mechanical Engineering, ul. Smoluchowskiego 25, 50-370 Wroclaw, Poland.
| | - D Robert Iskander
- Wroclaw University of Science and Technology, Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland.
| |
Collapse
|
40
|
Voorhees AP, Ho LC, Jan NJ, Tran H, van der Merwe Y, Chan K, Sigal IA. Whole-globe biomechanics using high-field MRI. Exp Eye Res 2017; 160:85-95. [PMID: 28527594 DOI: 10.1016/j.exer.2017.05.004] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Revised: 05/15/2017] [Accepted: 05/16/2017] [Indexed: 12/28/2022]
Abstract
The eye is a complex structure composed of several interconnected tissues acting together, across the whole globe, to resist deformation due to intraocular pressure (IOP). However, most work in the ocular biomechanics field only examines the response to IOP over smaller regions of the eye. We used high-field MRI to measure IOP induced ocular displacements and deformations over the whole globe. Seven sheep eyes were obtained from a local abattoir and imaged within 48 h using MRI at multiple levels of IOP. IOP was controlled with a gravity perfusion system and a cannula inserted into the anterior chamber. T2-weighted imaging was performed to the eyes serially at 0 mmHg, 10 mmHg, 20 mmHg and 40 mmHg of IOP using a 9.4 T MRI scanner. Manual morphometry was conducted using 3D visualization software to quantify IOP-induced effects at the globe scale (e.g. axial length and equatorial diameters) or optic nerve head scale (e.g. canal diameter, peripapillary sclera bowing). Measurement sensitivity analysis was conducted to determine measurement precision. High-field MRI revealed an outward bowing of the posterior sclera and anterior bulging of the cornea due to IOP elevation. Increments in IOP from 10 to 40 mmHg caused measurable increases in axial length in 6 of 7 eyes of 7.9 ± 5.7% (mean ± SD). Changes in equatorial diameter were minimal, 0.4 ± 1.2% between 10 and 40 mmHg, and in all cases less than the measurement sensitivity. The effects were nonlinear, with larger deformations at normal IOPs (10-20 mmHg) than at elevated IOPs (20-40 mmHg). IOP also caused measurable increases in the nasal-temporal scleral canal diameter of 13.4 ± 9.7% between 0 and 20 mmHg, but not in the superior-inferior diameter. This study demonstrates that high-field MRI can be used to visualize and measure simultaneously the effects of IOP over the whole globe, including the effects on axial length and equatorial diameter, posterior sclera displacement and bowing, and even changes in scleral canal diameter. The fact that the equatorial diameter did not change with IOP, in agreement with previous studies, indicates that a fixed boundary condition is a reasonable assumption for half globe inflation tests and computational models. Our results demonstrate the potential of high-field MRI to contribute to understanding ocular biomechanics, and specifically of the effects of IOP in large animal models.
Collapse
Affiliation(s)
- Andrew P Voorhees
- UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA
| | - Leon C Ho
- UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, China
| | - Ning-Jiun Jan
- UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Huong Tran
- UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Yolandi van der Merwe
- UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA
| | - Kevin Chan
- UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Louis J. Fox Center for Vision Restoration, University of Pittsburgh, Pittsburgh, PA, USA; New York University (NYU) Langone Eye Center, NYU Langone Medical Center, Department of Ophthalmology, NYU School of Medicine, New York, NY, United States.
| | - Ian A Sigal
- UPMC Eye Center, Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh, Pittsburgh, PA, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh, Pittsburgh, PA, USA; Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, USA; Louis J. Fox Center for Vision Restoration, University of Pittsburgh, Pittsburgh, PA, USA.
| |
Collapse
|
41
|
Fialová S, Augustin M, Fischak C, Schmetterer L, Handschuh S, Glösmann M, Pircher M, Hitzenberger CK, Baumann B. Posterior rat eye during acute intraocular pressure elevation studied using polarization sensitive optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2017; 8:298-314. [PMID: 28101419 PMCID: PMC5231300 DOI: 10.1364/boe.8.000298] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 12/01/2016] [Accepted: 12/12/2016] [Indexed: 05/05/2023]
Abstract
Polarization sensitive optical coherence tomography (PS-OCT) operating at 840 nm with axial resolution of 3.8 µm in tissue was used for investigating the posterior rat eye during an acute intraocular pressure (IOP) increase experiment. IOP was elevated in the eyes of anesthetized Sprague Dawley rats by cannulation of the anterior chamber. Three dimensional PS-OCT data sets were acquired at IOP levels between 14 mmHg and 105 mmHg. Maps of scleral birefringence, retinal nerve fiber layer (RNFL) retardation and relative RNFL/retina reflectivity were generated in the peripapillary area and quantitatively analyzed. All investigated parameters showed a substantial correlation with IOP. In the low IOP range of 14-45 mmHg only scleral birefringence showed statistically significant correlation. The polarization changes observed in the PS-OCT imaging study presented in this work suggest that birefringence of the sclera may be a promising IOP-related parameter to investigate.
Collapse
Affiliation(s)
- Stanislava Fialová
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
| | - Marco Augustin
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
| | - Corinna Fischak
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
- Department of Clinical Pharmacology, General Hospital and Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
| | - Leopold Schmetterer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
- Department of Clinical Pharmacology, General Hospital and Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
- Singapore Eye Research Institute, The Academia, 20 College Road, Discovery Tower Level 6, 169856 Singapore, Republic of Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Novena Campus, 11 Mandalay Road, 308232 Singapore, Republic of Singapore
| | - Stephan Handschuh
- VetCore Facility for Research and Technology, University of Veterinary Medicine Vienna, Veterinaerplatz 1, 1210 Vienna, Austria
| | - Martin Glösmann
- VetCore Facility for Research and Technology, University of Veterinary Medicine Vienna, Veterinaerplatz 1, 1210 Vienna, Austria
| | - Michael Pircher
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
| | - Christoph K. Hitzenberger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria
| |
Collapse
|