Diken Türksayar AA, Demirel M, Donmez MB, Olcay EO, Eyüboğlu TF, Özcan M. Comparison of wear and fracture resistance of additively and subtractively manufactured screw-retained, implant-supported crowns. J Prosthet Dent 2024; 132:154-164. [PMID: 37479623 DOI: 10.1016/j.prosdent.2023.06.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Revised: 06/20/2023] [Accepted: 06/21/2023] [Indexed: 07/23/2023]
Abstract
STATEMENT OF PROBLEM Additively manufactured resins indicated for fixed definitive prostheses have been recently marketed. However, knowledge on their wear and fracture resistance when fabricated as screw-retained, implant-supported crowns and subjected to artificial aging is limited. PURPOSE The purpose of this in vitro study was to evaluate the volume loss, maximum wear depth, and fracture resistance of screw-retained implant-supported crowns after thermomechanical aging when fabricated using additively and subtractively manufactured materials. MATERIAL AND METHODS Two additively manufactured composite resins (Crowntec [CT] and VarseoSmile Crown Plus [VS]) and 2 subtractively manufactured materials (1 reinforced composite resin, Brilliant Crios [BC] and 1 polymer-infiltrated ceramic network, Vita Enamic [EN]) were used to fabricate standardized screw-retained, implant-supported crowns. After fabrication, the crowns were cemented on titanium base abutments and then tightened to implants embedded in acrylic resin. A laser scanner with a triangular displacement sensor (LAS-20) was used to digitize the pre-aging state of the crowns. Then, all crowns were subjected to thermomechanical aging (1.2 million cycles under 50 N) and rescanned. A metrology-grade analysis software program (Geomagic Control X 2020.1) was used to superimpose post-aging scans over pre-aging scans to calculate the volume loss (mm3) and maximum wear depth (mm). Finally, all crowns were subjected to a fracture resistance test. Fracture resistance and volume loss were evaluated by using 1-way analysis of variance and Tukey Honestly significant difference (HSD) tests, whereas the Kruskal-Wallis and Dunn tests were used to analyze maximum wear depth. Chi-squared tests were used to evaluate the Weibull modulus and characteristic strength data (α=.05). RESULTS Material type affected the tested parameters (P<.001). CT and VS had higher volume loss and maximum wear depth than BC and EN (P<.001). EN had the highest fracture resistance among tested materials (P<.001), whereas BC had higher fracture resistance than CT (P=.011). The differences among tested materials were not significant when the Weibull modulus was considered (P=.199); however, VE had the highest characteristic strength (P<.001). CONCLUSIONS Additively manufactured screw-retained, implant-supported crowns had higher volume loss and maximum wear depth. All materials had fracture resistance values higher than the previously reported masticatory forces of the premolar region; however, the higher characteristic strength of the subtractively manufactured polymer-infiltrated ceramic network may indicate its resistance to mechanical complications.
Collapse
Affiliation(s)
- Almira Ada Diken Türksayar
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey; and Guest Researcher, ADMiRE Research Center-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria
| | - Münir Demirel
- Assistant Professor, Oral and Dental Health, Vocational School, Biruni University, Istanbul, Turkey
| | - Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; and Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Emin Orkun Olcay
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey
| | - Tan Fırat Eyüboğlu
- Associate Professor, Department of Endodontics, Istanbul Medipol University, Faculty of Dentistry, Istanbul, Turkey
| | - Mutlu Özcan
- Professor and Head, Clinic of Masticatory Disorders and Dental Biomaterials, Center for Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Khaledi AA, Shalileh S, Hejazi M, Giti R. Influence of screw channel angulation on reverse torque value and fracture resistance in monolithic zirconia restorations after thermomechanical cycling: an in-vitro study. BMC Oral Health 2024; 24:389. [PMID: 38532413 DOI: 10.1186/s12903-024-04171-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 03/20/2024] [Indexed: 03/28/2024] Open
Abstract
BACKGROUND While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.
Collapse
Affiliation(s)
- Amir Alireza Khaledi
- Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Shouka Shalileh
- Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Maryam Hejazi
- Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran
| | - Rashin Giti
- Department of Prosthodontics, Faculty of Dentistry, Shiraz University of Medical Sciences, Shiraz, Fars, Iran.
| |
Collapse
|
3
|
Neckel N, Pohl J, Preissner S, Wagendorf O, Sachse C, Vach K, Heiland M, Nahles S. Cross-sectional analysis comparing prefabricated titanium to individualized hybrid zirconia abutments for cemented zirconia based fixed dental prostheses: a critical concept assessment. Int J Implant Dent 2024; 10:13. [PMID: 38498247 PMCID: PMC10948712 DOI: 10.1186/s40729-024-00529-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 03/05/2024] [Indexed: 03/20/2024] Open
Abstract
PURPOSE Despite the differences in material properties and shapes among the different types of prefabricated titanium (pTiA) and individualized hybrid zirconia abutments (ihZiA), the biological and clinical relevance of materials and construction features remains vague. Yet, individualized ihZiA are increasingly implemented into daily routine aiming to satisfy rising expectations. The objective was to compare these two types of abutments in fixed dental prostheses (FDP). METHODS This cross-sectional study examined 462 implants in 102 patients comparing pTiA (52 patients) to ihZiA (50 patients) for FDP. These different treatment regimens were evaluated in terms of peri-implant health, radiographic bone loss, and oral-health related quality of life (OH-QoL) with special consideration of abutment type and superstructure design. RESULTS ihZiA showed significantly different design features than prefabricated pTiA, but the annual bone loss in both groups did not. Visible titanium in the esthetic zone negatively impacted OHIP 14 scores. The combination of an emergence angle (EA) of < 30° and a concave emergence profile (EP) as well as gingiva thickness (p = 0.002) at the time of the prosthetic restoration significantly improved the annual peri-implant bone loss, independently of the abutment type. CONCLUSION ihZiA showed comparable results to pTiA. To optimize the long-term outcome, not just material alone but generating adequate soft tissue thickness, minimizing the EA, and applying a concave EP seem to be the most relevant factors. To improve OH-QoL, particular attention must be paid to the esthetic zone.
Collapse
Affiliation(s)
- Norbert Neckel
- Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
| | - Josephine Pohl
- Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Saskia Preissner
- Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Oliver Wagendorf
- Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Claudia Sachse
- Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Kirstin Vach
- Faculty of Medicine and Medical Center, Institute of Medical Biometry and Medical Statistics, University of Freiburg, Freiburg, Germany
| | - Max Heiland
- Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| | - Susanne Nahles
- Department of Oral and Maxillofacial Surgery, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany
| |
Collapse
|
4
|
Rocha AA, Carvalho MAD, Bordin D, Cury AADB, Lazari-Carvalho PC. Biomechanical behavior of different designs of hybrid abutment-restoration on the posterior crown: a finite element analysis. Braz Dent J 2023; 34:140-149. [PMID: 38133088 PMCID: PMC10742363 DOI: 10.1590/0103-6440202305539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Accepted: 10/02/2023] [Indexed: 12/23/2023] Open
Abstract
This study aimed to evaluate the influence of material and crown design on the biomechanical behavior of implant-supported crowns with hybrid abutment (HA) through three-dimensional (3D) finite element analysis. The study factors were the type of material used as the mesostructure or crown (zirconia, lithium disilicate, and hybrid ceramic) and the crown design cemented to the titanium base (mesostructure cemented to the titanium base and a crown cemented on it (HaC); hybrid crown-abutment, the abutment and crown are manufactured as a single piece and cemented to the titanium base (HC); monolithic crown cemented on the titanium base and screwed to the implant (CS); and monolithic crown cemented on the titanium base (CC). Four 3D models were constructed using an implant with an internal connection, and an oblique load of 130 N was applied at 45° to the long axis of the implant. The models were evaluated using the von Mises stress for crown, abutment, screw, and implant and maximum principal stress for bone tissues. The lowest stresses occurred in the groups with a lower elastic modulus material, mainly hybrid ceramics, considered a material with greater resilience. The cemented crown group presented the lowest stress values. The stresses were concentrated in the cervical region of the crown at the titanium crown/base interface. Mesostructures made of materials with a higher elastic modulus exhibited a higher concentration of stress. The presence of a screw hole increased the stress concentration in the ceramic crown. Cemented ceramic crowns exhibited better biomechanical behavior than screw-retained crowns.
Collapse
Affiliation(s)
- Adna Alves Rocha
- School of Dentistry, Evangelical University of Goias (UniEVANGÉLICA), Anápolis, Brazil
| | - Marco Aurélio de Carvalho
- Department of Oral Rehabilitation, School of Dentistry, Evangelical University of Goias (UniEVANGÉLICA), Anápolis, Brazil
| | - Dimorvan Bordin
- School of Dentistry, Universus Veritas UNG, Guarulhos, SP Brazil
- Universidade São Judas Tadeu, São Paulo, SP, Brazil
| | | | | |
Collapse
|
5
|
Demirel M, Diken Türksayar AA, Donmez MB. Fabrication trueness and internal fit of hybrid abutment crowns fabricated by using additively and subtractively manufactured resins. J Dent 2023; 136:104621. [PMID: 37453654 DOI: 10.1016/j.jdent.2023.104621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 07/11/2023] [Accepted: 07/12/2023] [Indexed: 07/18/2023] Open
Abstract
OBJECTIVES To evaluate the fabrication trueness and internal fit of hybrid abutment crowns fabricated by using additively and subtractively manufactured restorative materials. METHODS A maxillary first premolar crown with a screw access channel was designed onto a digitized master titanium base abutment. This file was used to fabricate 40 crowns additively (Crowntec (CT) and VarseoSmile Crown Plus (VS)) or subtractively (Brilliant Crios (BC) and Vita Enamic (EN)) (n = 10). Crowns were digitized with an intraoral scanner and root mean square method was used to evaluate fabrication trueness. Master abutment and the crowns when seated on the abutment were also digitized with the same intraoral scanner and triple scan method was used to evaluate internal fit. Data were analyzed either with 1-way ANOVA (surface deviations) or Kruskal-Wallis (internal fit) tests (α= 0.05). RESULTS CT had the highest overall, external, and marginal surface deviations (P≤.030), whereas BC had the lowest external (P≤.001) and VS and EN had the lowest marginal surface deviations (P≤.007). BC had the highest intaglio surface deviations (P<.001). BC and EN had higher average gap values CT and VS (P≤.006); however, the differences within additively and subtractively manufactured materials were nonsignificant (P≥.858). CONCLUSIONS One of the tested additively manufactured resins (CT) resulted in mostly lower trueness than that of other materials. However, deviations at the intaglio and marginal surfaces were generally small and the maximum mean difference among test groups when average gap was considered was 17.4 µm. Therefore, clinical fit of hybrid abutment crowns fabricated with tested materials may be similar.
Collapse
Affiliation(s)
- Münir Demirel
- Assistant Professor, Oral and Dental Health, Vocational School, Biruni University, Istanbul, Turkey
| | - Almira Ada Diken Türksayar
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Biruni University, Istanbul, Turkey; Guest Researcher, ADMiRE Research Center-Additive Manufacturing, Intelligent Robotics, Sensors and Engineering, School of Engineering and IT, Carinthia University of Applied Sciences, Villach, Austria
| | - Mustafa Borga Donmez
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Visiting Researcher, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| |
Collapse
|
6
|
Alshamrani A, Alhotan A, Owais A, Ellakwa A. The Clinical Potential of 3D-Printed Crowns Reinforced with Zirconia and Glass Silica Microfillers. J Funct Biomater 2023; 14:jfb14050267. [PMID: 37233377 DOI: 10.3390/jfb14050267] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2023] [Revised: 05/09/2023] [Accepted: 05/09/2023] [Indexed: 05/27/2023] Open
Abstract
The development of 3D-printed crown resin materials with improved mechanical and physical properties is an area of growing interest in dentistry. This study aimed to develop a 3D-printed crown resin material modified with zirconia glass (ZG) and glass silica (GS) microfillers to enhance overall mechanical and physical properties. A total of 125 specimens were created and divided into five groups: control unmodified resin, 5% either ZG or GS reinforced 3D-printed resin, and 10% either ZG or GS reinforced 3D-printed resin. The fracture resistance, surface roughness, and translucency parameter were measured, and fractured crowns were studied under a scanning electron microscope. The results showed that 3D-printed parts that were strengthened with ZG and GS microfillers demonstrated comparable mechanical performance to unmodified crown resin but resulted in greater surface roughness, and only the group that contained 5% ZG showed an increase in translucency. However, it should be noted that increased surface roughness may impact the aesthetics of the crowns, and further optimisation of microfillers concentrations may be necessary. These findings suggest that the newly developed dental-based resins that incorporate microfillers could be suitable for clinical applications, but further studies are necessary to optimise the nanoparticle concentrations and investigate their long-term clinical outcomes.
Collapse
Affiliation(s)
- Abdullah Alshamrani
- Oral Rehabilitation & Dental Biomaterial and Bioengineering, The University of Sydney, Sydney, NSW 2006, Australia
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh P.O. Box 12372, Saudi Arabia
| | - Abdulaziz Alhotan
- Department of Dental Health, College of Applied Medical Sciences, King Saud University, Riyadh P.O. Box 12372, Saudi Arabia
| | - Ahmed Owais
- The X-ray Spectroscopy Node, Sydney Analytical, Core Research Facilities, The University of Sydney, Sydney, NSW 2006, Australia
| | - Ayman Ellakwa
- Oral Rehabilitation & Dental Biomaterial and Bioengineering, The University of Sydney, Sydney, NSW 2006, Australia
| |
Collapse
|
7
|
Sagheb K, Görgen CI, Döll S, Schmidtmann I, Wentaschek S. Preload and friction in an implant-abutment-screw complex including a carbon-coated titanium alloy abutment screw: an in vitro study. Int J Implant Dent 2023; 9:8. [PMID: 36947262 PMCID: PMC10033796 DOI: 10.1186/s40729-023-00473-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 03/13/2023] [Indexed: 03/23/2023] Open
Abstract
PURPOSE An experimental approach was designed to measure the preload force, the coefficient of friction and the component of the tightening torque that is needed to surmount the thread-friction in an implant-abutment-screw complex that includes a carbon-coated screw. With the determined preload values the coefficient of friction was calculated. METHODS 25 unused complexes, containing an implant, an abutment and a carbon-coated titanium alloy abutment screw, were tested. A custom load frame with two load cells and associated electronics was used. The threads were not lubricated. All abutment screws were torqued ten times to 25 Ncm. The produced preload values and a force that was proportional to the thread-friction component of the tightening torque were recorded. RESULTS Mean preload values decreased significantly with the number of repetitions (p < 0.0001) from initially 329.9 N ± 33.3 (range 255.7 to 383.9) to 253.7 N ± 36.8 (range 200.1 to 332.5) for the last tightening procedure. The corresponding change in the calculated coefficient of friction was 0.33 ± 0.04 (range 0.28 to 0.43) to 0.44 ± 0.07 (range 0.32 to 0.56). For the thread-friction no corresponding trend for consecutive tightening repetitions could be noticed. CONCLUSIONS In the investigated implant-abutment units, repeated use of a coated abutment screw appears to increase the friction of the screw head and thereby decrease the preload. These results indicate that a pre-used coated implant-abutment-screw will fail reaching optimal screw preload.
Collapse
Affiliation(s)
- K. Sagheb
- Department of Prosthodontics and Materials Science, University Medical Center of the University of Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | - C.-I. Görgen
- Department of Prosthodontics and Materials Science, University Medical Center of the University of Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | - S. Döll
- Department of Prosthodontics and Materials Science, University Medical Center of the University of Mainz, Augustusplatz 2, 55131 Mainz, Germany
| | - I. Schmidtmann
- Institute for Medical Biostatistics, Epidemiology and Informatics, University Medical Center of the University of Mainz, Obere Zahlbacher Straße 69, 55131 Mainz, Germany
| | - S. Wentaschek
- Department of Prosthodontics and Materials Science, University Medical Center of the University of Mainz, Augustusplatz 2, 55131 Mainz, Germany
| |
Collapse
|
8
|
Ožiūnas R, Sakalauskienė J, Staišiūnas L, Žekonis G, Žilinskas J, Janužis G. Physical and mechanical changes on titanium base of three different types of hybrid abutment after cyclic loading. J Adv Prosthodont 2023; 15:33-43. [PMID: 36908752 PMCID: PMC9992696 DOI: 10.4047/jap.2023.15.1.33] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2022] [Revised: 11/23/2022] [Accepted: 12/01/2022] [Indexed: 03/06/2023] Open
Abstract
PURPOSE This study investigated the physical and mechanical changes in the titanium base of three different hybrid abutment materials after cyclic loading by estimating the post-load reverse torque value (RTV), compressive side fulcrum wear pattern of titanium base, and surface roughness. MATERIALS AND METHODS A total of 24 dental implants were divided into three groups (n = 8 each): Group Z, LD, and P used zirconia, lithium disilicate, and polyetheretherketone, respectively, for hybrid abutment fabrication. RTV was evaluated after cyclic loading with 50 N for 1.2 × 106 chewing cycles. The compressive sides of the titanium bases were analyzed using a scanning electron microscope, and the roughness of the affected areas was measured using an optical profilometer after loading. Datasets were analyzed using Kruskal-Wallis test followed by Mann-Whitney tests with the Bonferroni correction (α = .05). RESULTS Twenty-three samples passed the test; one LD sample fractured after 770,474 cycles. Post-load RTV varied significantly depending on the hybrid-abutment material (P = .020). Group P had a significantly higher median of post-load RTVs than group Z (16.5 and 14.3 Ncm, respectively). Groups LD and P showed minor signs of wear, and group Z showed a more pronounced wear pattern. While evaluating compressive side affected area roughness of titanium bases, lower medians were shown in group LD (Ra 0.16 and Rq 0.22 µm) and group P (Ra 0.16 and Rq 0.23 µm) than in group Z (Ra 0.26 and Rq 0.34 µm); significant differences were found only among the unaffected surface and group Z. CONCLUSION The hybrid abutment material influences the post-load RTV. Group Z had a more pronounced wear pattern on the compressive side of titanium base; however, the surface roughness was not statistically different among the hybrid-abutment groups.
Collapse
Affiliation(s)
- Rimantas Ožiūnas
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Jurgina Sakalauskienė
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | | | - Gediminas Žekonis
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Juozas Žilinskas
- Department of Prosthodontics, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania
| | - Gintaras Janužis
- Department of Maxillofacial Surgery, Lithuanian University of Health Sciences, Kaunas, Lithuania
| |
Collapse
|
9
|
Moreno ALDM, dos Santos DM, Bertoz APDM, Goiato MC. Abutment on Titanium-Base Hybrid Implant: A Literature Review. Eur J Dent 2022. [DOI: 10.1055/s-0042-1750801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022] Open
Abstract
AbstractAn increase in the use of Computer-Aided Design (CAD) and Computer-Aided Manufacturing (CAM) technologies challenges the conventional prosthetic fabrication procedures that are practical and centered on a digital workflow for the patient, especially for dental implants. Increasing workflow of digital restoration work, considering computer-used CAM for restoration technology systems and also fast/CAM for building restoration technology; fast/CAD, also known as abut-Base, has increased interest. Studies on adaptation of different restorative materials, on titanium (Ti)-base abutments, traction, and transformed cycling have become relevant. The objective of this work was to research, through literature studies, on restoration-type abutments. A total of 24 articles were found after searching the following terms in PubMed/Medline, Scopus, and Embase databases: “ti-base AND abutment.” Twenty-one manuscripts selected from the inclusion and exclusion criteria. After an analysis of these articles, it was concluded that the Ti-base abutment and components from the same manufacturer as the Implant should be used preferably; milled monolithic crowns designed to adapt to the Ti-base the hybrid abutment-crown assembly does not affect torque maintenance after thermal aging; the saliva and cleaning protocol of the Ti-base bonding surfaces can influence the operations of the Ti-base crowns; Ti-base and Crown surface treatment is recommended for better applicability and stability results, and the superiority of resin-based cements compared with other types of cements.
Collapse
Affiliation(s)
- André Luiz de Melo Moreno
- Department of Dental Materials and Prosthodontics, São Paulo State University, School of Dentistry, Araçatuba, São Paulo, Brazil
| | - Daniela Micheline dos Santos
- Department of Dental Materials and Prosthodontics, São Paulo State University, School of Dentistry, Araçatuba, São Paulo, Brazil
| | | | - Marcelo Coelho Goiato
- Department of Dental Materials and Prosthodontics, São Paulo State University, School of Dentistry, Araçatuba, São Paulo, Brazil
| |
Collapse
|
10
|
Favasuli L, Mascarenhas PS, Mauricio P. Laboratory Fracture Resilience of Hybrid Abutments Used in Oral Rehabilitation: A Systematic Review. J Funct Biomater 2022; 13:jfb13030120. [PMID: 35997458 PMCID: PMC9397101 DOI: 10.3390/jfb13030120] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 08/09/2022] [Accepted: 08/10/2022] [Indexed: 11/26/2022] Open
Abstract
When implants are required in prosthodontics treatment, one of the most important decisions is the choice of the final crown and the type of connection to the implant through the abutment. Hybrid abutments are becoming a primary choice. They are projected and produced with materials whose properties guarantee the required mechanical features (including resistance) and take advantage of the hybrid abutment crown retention between screw and cement. However, a review of the mechanical resistance of the different abutment types and associated materials is still lacking. This review aimed to study the in vitro mechanical efficiency of the hybrid abutments used in oral rehabilitation. Methods: A systematic review was conducted using the PubMed, B-on, and Google Scholar databases according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Results: 75 articles were identified from all databases, and 33 were selected after abstract screening. Thus, 21 studies were included in the review after full-text reading. Among the materials used for crowns, lithium disilicate was, aesthetically, the primary choice for its aesthetic and moderate strength. On the other hand, zirconia showed the best fracture resistance. Regarding the different kinds of abutments, there is still some lack of knowledge about the best design. Conclusions: Within the limitations of this systematic review, we can conclude that hybrid pillars are an excellent choice for oral rehabilitation through implants, showing improved resistance when including materials such as zirconia and lithium disilicate.
Collapse
|
11
|
Donmez MB, Okutan Y. Marginal gap and fracture resistance of implant-supported 3D-printed definitive composite crowns: An in vitro study. J Dent 2022; 124:104216. [PMID: 35803388 DOI: 10.1016/j.jdent.2022.104216] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 06/20/2022] [Accepted: 07/04/2022] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVES To compare the marginal gap and fracture resistance of implant-supported 3-dimensional (3D) printed definitive composite crowns with those fabricated by using 3 different millable materials. MATERIAL AND METHODS A prefabricated abutment was digitized by using a laboratory scanner (E4 Lab Scanner) and a complete-coverage maxillary first premolar crown was designed (Dental Designer). Forty crowns were fabricated either by 3D printing (Saremco Print Crowntec, SP) or milling (Brilliant Crios, BC; Vita Enamic, VE; Cerasmart 270, CS) (n = 10). Baseline marginal gap values were evaluated by measuring 60 predetermined points on an abutment (15 points for each side) with a stereomicroscope at ×40 magnification. Marginal gap values were reevaluated after adhesive cementation. Load-to-fracture test was performed by using a universal testing machine. Two-way analysis of variance (ANOVA) was used to evaluate the effect of material type and cementation on marginal gap values. While Tukey HSD tests were used to compare the materials' marginal gap values before and after cementation, the effect of cementation on marginal gap values within each material was analyzed by using paired samples t-tests. Fracture resistance data were analyzed by using 1-way ANOVA (α=0.05). RESULTS Material type and cementation significantly affected marginal gap values (P < .001). Regardless of cementation, SP had the lowest marginal gap values (P < .001), while the differences among milled crowns were nonsignificant (P ≥ .14). Cementation significantly increased the marginal gap values (P < .001). Material type did not affect fracture resistance values (F = 1.589, P = .209). CONCLUSION Implant-supported 3D-printed composite crowns showed higher marginal adaptation compared with the milled crowns before and after cementation. In addition, all crowns endured similar forces before fracture.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Yener Okutan
- Department of Prosthodontics, Aydin Adnan Menderes University Faculty of Dentistry, Aydin, Turkey.
| |
Collapse
|
12
|
The effect of aging on the fracture resistance of different types of screw-cement-retained implant-supported zirconia-based restorations. PLoS One 2022; 17:e0270527. [PMID: 35749553 PMCID: PMC9232153 DOI: 10.1371/journal.pone.0270527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2022] [Accepted: 06/11/2022] [Indexed: 11/19/2022] Open
Abstract
Structural durability of screw-cement-retained implant-supported zirconia-based restorations is an important factor in choosing the best type of restoration for clinical use. This study aimed to evaluate the effects of thermocycling on the fracture resistance of different types of screw-cement-retained implant-supported zirconia-based restoration. Two experimental groups (monolithic zirconia and porcelain-veneered zirconia) and a control group of porcelain-fused-to-metal restorations were fabricated via CAD-CAM (n = 14 per group). Half of the specimens of each group (n = 7) were subjected to 10000 thermal cycles. The compressive force was applied and the force leading to fracture was measured by using a Universal Testing Machine. The fractured modes were classified under a scanning electron microscope. The data were analyzed through two-way ANOVA, one-way ANOVA, and independent samples t-test (α = 0.05). Among the non-thermocycled subgroups, the monolithic zirconia specimens were significantly more fracture-resistant than the porcelain-veneered zirconia and porcelain-fused-to-metal groups (P<0.05); but it was not the same with aging (P>0.05). Thermocycling decreased the fracture resistance of all groups; however, the difference was not statistically significant (P<0.05). The monolithic zirconia presented higher fracture resistance than the bilayered restorations for screw-cement retained implant-supported restorations. Thermocycling decreased the fracture resistance of all types of restorations insignificantly which can be clinically important.
Collapse
|
13
|
Nawafleh N, Elshiyab S, Öchsner A, George R. In Vitro Fatigue and Fracture Load of Monolithic Ceramic Crowns Supported by Hybrid Abutment. Open Dent J 2021. [DOI: 10.2174/1874210602115010664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Objective:
This study evaluated the performance of zirconia and lithium disilicate crowns supported by implants or cemented to epoxy resin dies.
Methods:
Eigthy zirconia and lithium disilicate crowns each were prepared and assigned in four groups according to the crown material and supporting structure combinations (implant-supported zirconia, die-supported zirconia, implant-supported lithium disilicate, and die-supported lithium disilicate). Ten crowns in each group acted as control while the rest (n=10) underwent thermocycling and fatigue with 100 N loading force for 1.5 million cycles. Specimens were then loaded to fracture in a universal testing machine. Data were analysed using one-way ANOVA and Tukey multiple comparison test with a 95% level of significance.
Results:
No implants or crown failure occurred during fatigue. The mean fracture load values (control, fatigued) in newton were as follows: (4054, 3344) for implant-supported zirconia, (3783, 3477) for die-supported zirconia, (2506, 2207) for implant-supported lithium disilicate, and (2159, 1806) for die-supported lithium disilicate. Comparing the control with the corresponding fatigued subgroup showed a significantly higher fracture load mean of the control group in all cases. Zirconia showed a significantly higher fracture load mean than lithium disilicate (P=0.001, P<0.001). However, comparing crowns made from the same material according to the supporting structure showed no significant difference (P=0.923, P=0.337).
Conclusion:
Zirconia and lithium disilicate posterior crowns have adequate fatigue and fracture resistance required for posterior crowns. However, when heavy fatigue forces are expected, zirconia material is preferable over lithium disilicate. Zirconia and lithium disilicate implant-supported crowns cemented to hybrid abutments should have satisfactory clinical performance.
Collapse
|
14
|
Al-Thobity AM. Titanium Base Abutments in Implant Prosthodontics: A Literature Review. Eur J Dent 2021; 16:49-55. [PMID: 34794201 PMCID: PMC8890922 DOI: 10.1055/s-0041-1735423] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
Implant abutments are essential components in restoring dental implants. Titanium base abutments were introduced to overcome issues related to existing abutments, such as the unesthetic appearance of titanium abutments and the low fracture strength of ceramic abutments. This study aimed to comprehensively review studies addressing the mechanical and clinical behaviors of titanium base abutments. A search was performed on PubMed/MEDLINE, Web of Science, Google Scholar, and Scopus databases to find articles that were published in English until December 2020 and that addressed the review purpose. A total of 33 articles fulfilled the inclusion criteria and were included for data extraction and review.
In vitro
studies showed that titanium base abutments had high fracture strength, adequate retention values, particularly with resin cement, and good marginal and internal fit. Although the clinical assessment of titanium base abutments was limited, they showed comparable performance with conventional abutments in short-term evaluation, especially in the anterior and premolar areas. Titanium base abutments can be considered a feasible treatment option for restoring dental implants, but long-term clinical studies are required for a better assessment.
Collapse
Affiliation(s)
- Ahmad M Al-Thobity
- Department of Substitutive Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
15
|
Sarafidou K, Vasileiadi G, Louvrou MK, Moldovani E, Koidis P, Kokoti M, Bakopoulou A. Screwmentable implant-supported prostheses: A systematic review. J Prosthet Dent 2021:S0022-3913(21)00506-0. [PMID: 34740460 DOI: 10.1016/j.prosdent.2021.08.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 08/24/2021] [Accepted: 08/24/2021] [Indexed: 10/19/2022]
Abstract
STATEMENT OF PROBLEM Screwmentable prostheses were developed to combine the benefits of screw retention and cement retention. However, data are limited on the clinical performance of this type of prosthesis. PURPOSE The purpose of this systematic review was to collect scientific evidence on screwmentable prostheses and evaluate their long-term clinical behavior. MATERIAL AND METHODS An electronic search was conducted by 2 independent reviewers for articles published in scientific dental journals in English from 2004 to April 2020. The search strategy followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Inclusion criteria were scientific studies concerning the screwmentable type of prosthesis. RESULTS The search provided 494 records. Of these, 24 studies fulfilled the inclusion criteria and were included in the review. The included articles presented significant heterogeneity concerning the manufacturing process and the materials used. One randomized clinical trial, 2 prospective clinical studies, 14 in vitro studies, 3 protocol descriptions, 1 case series, and 3 case reports were included. CONCLUSIONS Based on the systematic search of the literature, it is concluded that the screwmentable prosthesis combines advantages of both cement-retained and screw-retained restorations, including passive fit, retrievability, excess cement control, tissue-friendly emergence profile, and improved esthetics. Nevertheless, data from well-designed clinical trials are limited, and further research is required to provide evidence on their long-term clinical behavior.
Collapse
Affiliation(s)
- Katia Sarafidou
- Post-doctoral Researcher/Clinical Instructor, Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki (A.U.Th), Thessaloniki, Greece
| | - Georgia Vasileiadi
- Post-graduate student, Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki (A.U.Th), Thessaloniki, Greece
| | - Marilena Kalliopi Louvrou
- Dental Surgeon, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki (A.U.Th), Thessaloniki, Greece
| | - Eirini Moldovani
- Undergraduate student, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki (A.U.Th), Thessaloniki, Greece
| | - Petros Koidis
- Professor and Chairman, Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki (A.U.Th), Thessaloniki, Greece
| | - Maria Kokoti
- Assistant Professor, Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki (A.U.Th), Thessaloniki, Greece
| | - Athina Bakopoulou
- Associate Professor, Department of Prosthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki (A.U.Th), Thessaloniki, Greece.
| |
Collapse
|
16
|
Donmez MB, Diken Turksayar AA, Olcay EO, Sahmali SM. Fracture Resistance of Single-Unit Implant-Supported Crowns: Effects of Prosthetic Design and Restorative Material. J Prosthodont 2021; 31:348-355. [PMID: 34383979 DOI: 10.1111/jopr.13415] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/10/2021] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To evaluate the fracture resistance and fracture patterns of single implant-supported crowns with different prosthetic designs and materials. MATERIALS AND METHODS One hundred and forty-four identical crowns were fabricated from zirconia-reinforced lithium silicate (ZLS), leucite-based (LGC), and lithium disilicate (LDS) glass-ceramics, reinforced composite (RC), translucent zirconia (ZR), and ceramic-reinforced polyetheretherketone (P). These crowns were divided into 3 subgroups according to restoration design: cementable crowns on a prefabricated titanium abutment, cement-retained crown on a zirconia-titanium base abutment, and screw-cement crown (n = 8). After adhesive cementation, restorations were subjected to thermal-cycling and loaded until fracture. The fracture patterns were evaluated under a stereomicroscope. Statistical analysis was performed by using 2-way ANOVA/Bonferroni multiple comparison post hoc test (α = 0.05). RESULTS For each prosthetic design, ZR presented the highest fracture resistance (p ≤ 0.005). Other than the differences with ZLS and RC for screw-cement crowns (p > 0.05) and RC for crowns on zirconia-titanium base abutments (p > 0.05), LGC showed the lowest fracture resistance. P endured higher loads than LDS (p < 0.001), except for the crowns on zirconia-titanium base abutments (p > 0.05). Cementable crowns presented the highest fracture resistance (p < 0.001), other than LGC and LDS. The differences between LGC crowns (p > 0.05) or LDS crowns on prefabricated titanium and zirconia-titanium abutments were nonsignificant (p = 0.133). Fragmented crown fracture was predominant in most of the restorations. Screw and abutment fractures were observed in ZR screw-cement crowns, and all P crowns were separated from the abutments. CONCLUSIONS Restorative material and restoration design affect the fracture resistance and fracture pattern of implant-supported single-unit restorations. Clinicians may restore single-unit implants in premolar sites with the materials and prosthetic designs tested in the present study.
Collapse
Affiliation(s)
- Mustafa Borga Donmez
- Biruni University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| | | | - Emin Orkun Olcay
- Biruni University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| | - Sevil Meral Sahmali
- Biruni University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey
| |
Collapse
|
17
|
Matos JD, Arcila LV, Ortiz LP, Lopes GR, Anami LC, Ramos NC, Saavedra GS, Tribst JP, Bottino MA. Hybrid abutment during prosthetic planning and oral rehabilitation. Minerva Dent Oral Sci 2021; 71:107-116. [PMID: 33929134 DOI: 10.23736/s2724-6329.21.04479-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND The present study aims to describe through a literature review, the characteristics and properties of hybrid abutments, as well as their proper use as a new rehabilitation strategy. METHODS A bibliographic search was conducted in the main health databases Pubmed (www.pubmed.gov) and Google Scholar (www.scholar.google.com.br), in which studies published from 2001 to 2020 were collected. Laboratory studies, case reports, systematic and literature reviews were included. Therefore, articles that do not adress the characteristics and properties of hybrid abutments were excluded. In addition, studies that did not report the use of hybrid abutments as a new rehabilitation strategy. RESULTS According to the inclusion and exclusion criteria, 80 research articles were selected and 20 were excluded, while 25 in vitro, 17 in vivo and 9 in silico studies were reviewed. CONCLUSIONS The literature demonstrates that hybrid abutments are an excellent alternative in cases of implant-supported rehabilitation, presenting high esthetic results, associated with good soft tissue response, periimplant marginal bone stability and adequate stress distribution during the masticatory loads dissipation.
Collapse
Affiliation(s)
- Jefferson D Matos
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil -
| | - Laura V Arcila
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| | - Laura P Ortiz
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| | - Guilherme R Lopes
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| | - Lilian C Anami
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| | - Nathália C Ramos
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| | - Guilherme S Saavedra
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| | - João P Tribst
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| | - Marco A Bottino
- Department of Prosthodontics and Dental Materials, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos, SP, Brazil
| |
Collapse
|