1
|
Yan X, Wang Y, Li W, Zhu M, Wang W, Xu C, Li K, Liu B, Shi X. A preliminary study on the application of electrical impedance tomography based on cerebral perfusion monitoring to intracranial pressure changes. Front Neurosci 2024; 18:1390977. [PMID: 38863884 PMCID: PMC11166027 DOI: 10.3389/fnins.2024.1390977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Accepted: 05/10/2024] [Indexed: 06/13/2024] Open
Abstract
Background In intracranial pathologic conditions of intracranial pressure (ICP) disturbance or hemodynamic instability, maintaining appropriate ICP may reduce the risk of ischemic brain injury. The change of ICP is often accompanied by the change of intracranial blood status. As a non-invasive functional imaging technique, the sensitivity of electrical impedance tomography (EIT) to cerebral hemodynamic changes has been preliminarily confirmed. However, no team has conducted a feasibility study on the dynamic detection of ICP by EIT technology from the perspective of non-invasive whole-brain blood perfusion monitoring. In this study, human brain EIT image sequence was obtained by in vivo measurement, from which a variety of indicators that can reflect the tidal changes of the whole brain impedance were extracted, in order to establish a new method for non-invasive monitoring of ICP changes from the level of cerebral blood perfusion monitoring. Methods Valsalva maneuver (VM) was used to temporarily change the cerebral blood perfusion status of volunteers. The electrical impedance information of the brain during this process was continuously monitored by EIT device and real-time imaging was performed, and the hemodynamic indexes of bilateral middle cerebral arteries were monitored by transcranial Doppler (TCD). The changes in monitoring information obtained by the two techniques were compared and observed. Results The EIT imaging results indicated that the image sequence showed obvious tidal changes with the heart beating. Perfusion indicators of vascular pulsation obtained from EIT images decreased significantly during the stabilization phase of the intervention (PAC: 242.94 ± 100.83, p < 0.01); perfusion index which reflects vascular resistance increased significantly in the stable stage of intervention (PDT: 79.72 ± 18.23, p < 0.001). After the intervention, the parameters gradually returned to the baseline level before compression. The changes of EIT indexes in the whole process are consistent with the changes of middle cerebral artery velocity related indexes shown in TCD results. Conclusion The EIT image combined with the blood perfusion index proposed in this paper can reflect the decrease of cerebral blood flow under the condition of increased ICP in real time and intuitively. With the advantages of high time resolution and high sensitivity, EIT provides a new idea for non-invasive bedside measurement of ICP.
Collapse
Affiliation(s)
- Xiaoheng Yan
- Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
- Belt and Road Joint Laboratory on Measurement and Control Technology, Huazhong University of Science and Technology, Wuhan, China
| | - Yu Wang
- Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
| | - Weichen Li
- College of Life Sciences, Northwest University, Xi’an, China
| | - Mingxu Zhu
- Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Weice Wang
- Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Canhua Xu
- Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Kun Li
- Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
| | - Benyuan Liu
- Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| | - Xuetao Shi
- Department of Biomedical Engineering, Air Force Medical University, Xi’an, China
| |
Collapse
|
2
|
Wu H, Shi J, Sun X, Lu M, Liao A, Li Y, Xiao L, Zhou C, Dong W, Geng Z, Yuan L, Guo R, Chen M, Cheng X, Zhu W. Predictive effect of net water uptake on futile recanalisation in patients with acute large-vessel occlusion stroke. Clin Radiol 2024; 79:e599-e606. [PMID: 38310056 DOI: 10.1016/j.crad.2024.01.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 12/03/2023] [Accepted: 01/06/2024] [Indexed: 02/05/2024]
Abstract
AIM To determine whether net water uptake (NWU) based on automated software evaluation could predict futile recanalisation in patients with acute anterior circulation large-vessel occlusion (LVO). MATERIALS AND METHODS Patients with acute anterior circulation LVO undergoing mechanical thrombectomy in Jinling Hospital were evaluated retrospectively. NWU and other baseline data were evaluated by performing univariate and multivariate analyses. The primary endpoint was 90-day modified Rankin scale score ≥3. A nomogram to predict poor clinical outcomes was developed based on multivariate logistic regression analysis. RESULTS Overall, 135 patients who underwent thrombectomy with a TICI grade ≥2b were enrolled. In multivariate logistic regression analysis, the following factors were identified as independent predictors of futile recanalisation: age (odds ratio [OR]: 1.055, 95 % confidence interval [CI]: 1.004-1.110, p=0.035), female (OR: 0.289, 95 % CI: 0.098-0.850, p=0.024), hypertension (OR: 3.182, 95 % CI: 1.160-8.728, p=0.025), high blood glucose level (OR: 1.36, 95 % CI: 1.087-1.701, p=0.007), admission National Institutes of Health Stroke Scale score (OR: 1.082, 95 % CI: 1.003-1.168, p=0.043), and NWU (OR: 1.312, 95 % CI: 1.038-1.659, p=0.023). CONCLUSIONS NWU based on Alberta Stroke Program Early Computed Tomography (CT) Score (ASPECTS) could be used to predict the occurrence of futile recanalisation in patients with acute anterior circulation LVO ischaemic stroke.
Collapse
Affiliation(s)
- H Wu
- Department of Neurology, Third People's Hospital of Yancheng, Yancheng 224001, Jiangsu, China; Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - J Shi
- Department of Medical Imaging, Jinling Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - X Sun
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - M Lu
- Department of Neurology, Jinling Hospital, Nanjing Medical University, Nanjing, Jiangsu, China
| | - A Liao
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - Y Li
- Department of Neurology, Jinling Hospital, The First School of Clinical Medicine, Southern Medical University, Nanjing, Jiangsu, China
| | - L Xiao
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - C Zhou
- Department of Medical Imaging, Jinling Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China
| | - W Dong
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - Z Geng
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - L Yuan
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - R Guo
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China
| | - M Chen
- Department of Neurology, Third People's Hospital of Yancheng, Yancheng 224001, Jiangsu, China
| | - X Cheng
- Department of Medical Imaging, Jinling Hospital, Nanjing University School of Medicine, Nanjing, Jiangsu, China.
| | - W Zhu
- Department of Neurology, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Nanjing 210002, Jiangsu, China.
| |
Collapse
|
3
|
Karimi F, Neufeld E, Fallahi A, Boraschi A, Zwanenburg JJM, Spiegelberg A, Kurtcuoglu V, Kuster N. Theory for a non-invasive diagnostic biomarker for craniospinal diseases. Neuroimage Clin 2023; 37:103280. [PMID: 36508887 PMCID: PMC9763738 DOI: 10.1016/j.nicl.2022.103280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 12/01/2022] [Accepted: 12/02/2022] [Indexed: 12/13/2022]
Abstract
Monitoring intracranial pressure (ICP) and craniospinal compliance (CC) is frequently required in the treatment of patients suffering from craniospinal diseases. However, current approaches are invasive and cannot provide continuous monitoring of CC. Dynamic exchange of blood and cerebrospinal fluid (CSF) between cranial and spinal compartments due to cardiac action transiently modulates the geometry and dielectric properties of the brain. The resulting impedance changes can be measured and might be usable as a non-invasive CC surrogate. A numerically robust and computationally efficient approach based on the reciprocity theorem was developed to compute dynamic impedance changes resulting from small geometry and material property changes. The approach was successfully verified against semi-analytical benchmarks, before being combined with experimental brain pulsation data to study the information content of the impedance variation. The results indicate that the measurable signal is dominated by the pulsatile displacement of the cortical brain surface, with minor contributions from the ventricular surfaces and from changes in brain perfusion. Different electrode setups result in complementary information. The information content from the investigated three electrode pairs was employed to successfully infer subject-specific brain pulsation and motion features. This suggests that non-invasive CC surrogates based on impedance monitoring could be established.
Collapse
Affiliation(s)
- Fariba Karimi
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland; Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland.
| | - Esra Neufeld
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
| | - Arya Fallahi
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland; Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland
| | - Andrea Boraschi
- The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland
| | - Jaco J M Zwanenburg
- Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Andreas Spiegelberg
- The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland
| | - Vartan Kurtcuoglu
- The Interface Group, Institute of Physiology, University of Zurich, Zurich, Switzerland; Zurich Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland
| | - Niels Kuster
- Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland; Department of Information Technology and Electrical Engineering, Swiss Federal Institute of Technology (ETH), Zurich, Switzerland
| |
Collapse
|
4
|
Emerging trends and hot spots on electrical impedance tomography extrapulmonary applications. Heliyon 2022; 8:e12458. [PMID: 36619470 PMCID: PMC9812712 DOI: 10.1016/j.heliyon.2022.e12458] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Revised: 10/17/2022] [Accepted: 12/13/2022] [Indexed: 01/04/2023] Open
Abstract
Objective Electrical impedance tomography (EIT) develops rapidly in technology and applications. Nowadays EIT is used in multiple clinical and experimental scenarios including pulmonary, brain, and tissue monitoring, etc. The present study explores the research trends and hotspots on EIT extrapulmonary application research by bibliometrics analysis. Approach Publications on EIT extrapulmonary applications between 1987 and 2021 were retrieved from the Web of Science Core Collection database. For precise screening, search strategy "electrical impedance tomography" plus "hemodynamic" or "brain" or "nerve" or "cancer" or "venous" or "vessel" or "tumor" or "veterinary" or "tissue" or "cell" or "wearable" or "application" and excluding "lung", "ventilation" "respiratory", "pulmonary", "algorithm", "current", "voltage" or "electrode" were used. CiteSpace and VOSviewer were used to analyze the publication features, collaboration, keywords co-occurrence, and co-cited reference. Main results A total of 506 articles were finally identified. The global publication numbers on extrapulmonary applications gradually increased yearly in the past 30 years. The US, UK, and China contributed most three publications concerning EIT extrapulmonary applications. "tissues", "conductivity", "model" were research hotspots, and "cutaneous melanoma", "microstructure", "diagnosis" were recent topics (Portions of this research have previously been presented in poster form). Significance Overall, EIT extrapulmonary applications bibliometrics analysis provides a unique insight into research focus, current trends, and future directions.
Collapse
|
5
|
Mirhoseini M, Rezanejad Gatabi Z, Das S, Joveini S, Rezanezhad Gatabi I. Applications of Electrical Impedance Tomography in Neurology. Basic Clin Neurosci 2022; 13:595-608. [PMID: 37313030 PMCID: PMC10258591 DOI: 10.32598/bcn.2021.3087.1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/24/2021] [Accepted: 05/14/2021] [Indexed: 11/02/2023] Open
Abstract
Introduction Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteristics. The high potential of brain EIT is established in real-time supervision and early recognition of cerebral brain infarction, hemorrhage, and other diseases. In this paper, we review the studies on the neurological applications of EIT. Methods EIT calculates the internal electrical conductivity distribution of an organ by measuring its surface impedance. A series of electrodes are placed on the surface of the target tissue, and small alternating currents are injected. The related voltages are then observed and analyzed. The electrical permittivity and conductivity distributions inside the tissue are reconstructed by measuring the electrode voltages. Results The electrical characteristic of biological tissues is remarkably dependent on their structures. Some tissues are better electrical conductors than the others since they have more ions that can carry the electrical charges. This difference is attributed to changes in cellular water content, membrane properties, and destruction of tight junctions within cell membranes. Conclusion EIT is an extremely practical device for brain imaging, capturing fast electrical activities in the brain, imaging epileptic seizures, detecting intracranial bleeding, detecting cerebral edema, and diagnosing stroke.
Collapse
Affiliation(s)
- Mehri Mirhoseini
- Amol Faculty of Paramedical Sciences, Mazandaran University of Medical Sciences, Sari, Iran
| | - Zahra Rezanejad Gatabi
- Department of Pharmaceutics, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran
| | - Sayantan Das
- Faculty/College of Science and Mathematics, Texas A&M University, San Antonio, United States
| | - Sepideh Joveini
- Department of Pharmaceutics, Faculty of Pharmacy, Mazandaran University of Medical Sciences, Sari, Iran
| | - Iman Rezanezhad Gatabi
- Department of Electrical and Computer Engineering, Texas A&M University, College Station, United States
| |
Collapse
|
6
|
Ouypornkochagorn T, Terzija N, Wright P, Davidson JL, Polydorides N, McCann H. Scalp-Mounted Electrical Impedance Tomography of Cerebral Hemodynamics. IEEE SENSORS JOURNAL 2022; 22:4569-4580. [PMID: 35673527 PMCID: PMC9093315 DOI: 10.1109/jsen.2022.3145587] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/10/2022] [Accepted: 01/11/2022] [Indexed: 06/15/2023]
Abstract
An Electrical Impedance Tomography (EIT) system has been developed for dynamic three-dimensional imaging of changes in conductivity distribution in the human head, using scalp-mounted electrodes. We attribute these images to changes in cerebral perfusion. At 100 frames per second (fps), voltage measurement is achieved with full-scale signal-to-noise ratio of 105 dB and common-mode rejection ratio > 90 dB. A novel nonlinear method is presented for 3-D imaging of the difference in conductivity distribution in the head, relative to a reference time. The method achieves much reduced modelling error. It successfully localizes conductivity inclusions in experimental and simulation tests, where previous methods fail. For > 50 human volunteers, the rheoencephalography (REG) waveform is observed in EIT voltage measurements for every volunteer, with peak-to-peak amplitudes up to approx. 50 μVrms. Images are presented of the change in conductivity distribution during the REG/cardiac cycle, at 50 fps, showing maximum local conductivity change of approx. 1% in grey/white matter. A total of 17 tests were performed during short (typically 5s) carotid artery occlusions on 5 volunteers, monitored by Transcranial Doppler ultrasound. From EIT measurements averaged over complete REG/cardiac cycles, 13 occlusion tests showed consistently decreased conductivity of cerebral regions on the occluded side, and increased conductivity on the opposite side. The maximum local conductivity change during occlusion was approx. 20%. The simplicity of the carotid artery intervention provides a striking validation of the scalp-mounted measurement system in imaging cerebral hemodynamics, and the REG images indicate its unique combination of sensitivity and temporal resolution.
Collapse
Affiliation(s)
| | | | - Paul Wright
- Department of Electrical and Electronic EngineeringThe University of ManchesterManchesterM13 9PLU.K.
| | - John L. Davidson
- Department of Electrical and Electronic EngineeringThe University of ManchesterManchesterM13 9PLU.K.
| | - Nick Polydorides
- School of EngineeringThe University of EdinburghEdinburghEH9 3JLU.K.
| | - Hugh McCann
- School of EngineeringThe University of EdinburghEdinburghEH9 3JLU.K.
| |
Collapse
|
7
|
Ke XY, Hou W, Huang Q, Hou X, Bao XY, Kong WX, Li CX, Qiu YQ, Hu SY, Dong LH. Advances in electrical impedance tomography-based brain imaging. Mil Med Res 2022; 9:10. [PMID: 35227324 PMCID: PMC8883715 DOI: 10.1186/s40779-022-00370-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 02/08/2022] [Indexed: 11/10/2022] Open
Abstract
Novel advances in the field of brain imaging have enabled the unprecedented clinical application of various imaging modalities to facilitate disease diagnosis and treatment. Electrical impedance tomography (EIT) is a functional imaging technique that measures the transfer impedances between electrodes on the body surface to estimate the spatial distribution of electrical properties of tissues. EIT offers many advantages over other neuroimaging technologies, which has led to its potential clinical use. This qualitative review provides an overview of the basic principles, algorithms, and system composition of EIT. Recent advances in the field of EIT are discussed in the context of epilepsy, stroke, brain injuries and edema, and other brain diseases. Further, we summarize factors limiting the development of brain EIT and highlight prospects for the field. In epilepsy imaging, there have been advances in EIT imaging depth, from cortical to subcortical regions. In stroke research, a bedside EIT stroke monitoring system has been developed for clinical practice, and data support the role of EIT in multi-modal imaging for diagnosing stroke. Additionally, EIT has been applied to monitor the changes in brain water content associated with cerebral edema, enabling the early identification of brain edema and the evaluation of mannitol dehydration. However, anatomically realistic geometry, inhomogeneity, cranium completeness, anisotropy and skull type, etc., must be considered to improve the accuracy of EIT modeling. Thus, the further establishment of EIT as a mature and routine diagnostic technique will necessitate the accumulation of more supporting evidence.
Collapse
Affiliation(s)
- Xi-Yang Ke
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Qi Huang
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China
| | - Xue Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Xue-Ying Bao
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei-Xuan Kong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China
| | - Cheng-Xiang Li
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Yu-Qi Qiu
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Si-Yi Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China.
| | - Li-Hua Dong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China. .,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China. .,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| |
Collapse
|
8
|
Abboud T, Mielke D, Rohde V. Mini Review: Impedance Measurement in Neuroscience and Its Prospective Application in the Field of Surgical Neurooncology. Front Neurol 2022; 12:825012. [PMID: 35111132 PMCID: PMC8801870 DOI: 10.3389/fneur.2021.825012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 12/27/2021] [Indexed: 11/13/2022] Open
Abstract
Impedance measurement of human tissue can be performed either in vivo or ex vivo. The majority of the in-vivo approaches are non-invasive, and few are invasive. To date, there is no gold standard for impedance measurement of intracranial tissue. In addition, most of the techniques addressing this topic are still experimental and have not found their way into clinical practice. This review covers available impedance measurement approaches in the neuroscience in general and specifically addresses recent advances made in the application of impedance measurement in the field of surgical neurooncology. It will provide an understandable picture on impedance measurement and give an overview of limitations that currently hinders clinical application and require future technical and conceptual solutions.
Collapse
|
9
|
Bronk TS, Everitt AC, Murphy EK, Halter RJ. Novel Electrode Placement in Electrical Bioimpedance-Based Stroke Detection: Effects on Current Penetration and Injury Characterization in a Finite Element Model. IEEE Trans Biomed Eng 2021; 69:1745-1757. [PMID: 34813463 PMCID: PMC9172913 DOI: 10.1109/tbme.2021.3129734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Reducing time-to-treatment and providing acute management in stroke are essential for patient recovery. Electrical bioimpedance (EBI) is an inexpensive and non-invasive tissue measurement approach that has the potential to provide novel continuous intracranial monitoring-something not possible in current standard-of-care. While extensive previous work has evaluated the feasibility of EBI in diagnosing stroke, high-impedance anatomical features in the head have limited clinical translation. METHODS The present study introduces novel electrode placements near highly-conductive cerebral spinal fluid (CSF) pathways to enhance electrical current penetration through the skull and increase detection accuracy of neurologic damage. Simulations were conducted on a realistic finite element model (FEM). Novel electrode placements at the tear ducts, soft palate and base of neck were evaluated. Classification accuracy was assessed in the presence of signal noise, patient variability, and electrode positioning. RESULTS Algorithms were developed to successfully determine stroke etiology, location, and size relative to impedance measurements from a baseline scan. Novel electrode placements significantly increased stroke classification accuracy at various levels of signal noise (e.g. p < 0.001 at 40 dB). Novel electrodes also amplified current penetration, with up to 30% increase in current density and 57% increased sensitivity in central intracranial regions (p<0.001). CONCLUSION These findings support the use of novel electrode placements in EBI to overcome prior limitations, indicating a potential approach to increasing the technology's clinical utility in stroke identification. SIGNIFICANCE A non-invasive EBI monitor for stroke could provide essential timely intervention and care of stroke patients.
Collapse
|
10
|
Everitt A, Root B, Calnan D, Manwaring P, Bauer D, Halter R. A bioimpedance-based monitor for real-time detection and identification of secondary brain injury. Sci Rep 2021; 11:15454. [PMID: 34326387 PMCID: PMC8322167 DOI: 10.1038/s41598-021-94600-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 07/13/2021] [Indexed: 01/01/2023] Open
Abstract
Secondary brain injury impacts patient prognosis and can lead to long-term morbidity and mortality in cases of trauma. Continuous monitoring of secondary injury in acute clinical settings is primarily limited to intracranial pressure (ICP); however, ICP is unable to identify essential underlying etiologies of injury needed to guide treatment (e.g. immediate surgical intervention vs medical management). Here we show that a novel intracranial bioimpedance monitor (BIM) can detect onset of secondary injury, differentiate focal (e.g. hemorrhage) from global (e.g. edema) events, identify underlying etiology and provide localization of an intracranial mass effect. We found in an in vivo porcine model that the BIM detected changes in intracranial volume down to 0.38 mL, differentiated high impedance (e.g. ischemic) from low impedance (e.g. hemorrhagic) injuries (p < 0.001), separated focal from global events (p < 0.001) and provided coarse 'imaging' through localization of the mass effect. This work presents for the first time the full design, development, characterization and successful implementation of an intracranial bioimpedance monitor. This BIM technology could be further translated to clinical pathologies including but not limited to traumatic brain injury, intracerebral hemorrhage, stroke, hydrocephalus and post-surgical monitoring.
Collapse
Affiliation(s)
- Alicia Everitt
- Thayer School of Engineering, Dartmouth College, HB 8000, 14 Engineering Dr., Hanover, NH, 03755, USA.
| | - Brandon Root
- Neurological Surgery, Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| | - Daniel Calnan
- Neurological Surgery, Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| | | | - David Bauer
- Neurological Surgery, Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| | - Ryan Halter
- Thayer School of Engineering, Dartmouth College, HB 8000, 14 Engineering Dr., Hanover, NH, 03755, USA.,Neurological Surgery, Dartmouth Hitchcock Medical Center, Lebanon, NH, 03766, USA
| |
Collapse
|
11
|
Williams T, Bouazza-Marouf K, Zecca M, Green A. Analysis of the validity of the mathematical assumptions of electrical impedance tomography for human head tissues. Biomed Phys Eng Express 2021; 7. [PMID: 33513587 DOI: 10.1088/2057-1976/abe190] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 01/29/2021] [Indexed: 11/11/2022]
Abstract
Objective:To determine the validity of the key mathematical assumptions used in electrical impedance tomography for human head tissues over the frequency range of 10 Hz to 100 GHz.Approach:Conductivity and permittivity data collected from available literature for each tissue within the human head have been evaluated and critiqued. The most relevant dielectric tissue data for each tissue was then used to assess the validity of the mathematical assumptions of electrical impedance tomography in terms of their suitability for human head imaging in order to estimate related errors.Main Results:For induced currents with frequencies greater than 200 Hz the internal current source density is negligible. The assumption that magnetic effects are negligible is valid to an error of 1.7% for human head tissues for frequencies below 1 MHz. The capacitive effects are negligible for CSF, dura mater, blood, bone (cortical), and deep tissue skin for frequencies less than 3.2 MHz, 320 kHz, 25 kHz, 3.2 kHz, and 130 Hz respectively. However, the capacitive effects are not negligible for brain tissues, as the minimum error for brain tissues across the frequency range of 10 Hz to 100 GHz is 6.2% at 800 Hz, and the maximum error is 410% at 20 GHz.Significance:It is often assumed that the mathematical reduction of the base equations is valid for human head tissues over a broad frequency range; this study shows that these assumptions are not true for all tissues at all frequencies. False assumptions will result in greater errors and local distortions within tomographic images of the human head using electrical impedance tomography. This study provides the relationships between injected current frequency and the validity of the mathematical assumptions for each individual tissue, providing greater awareness of the magnitude of possible distortions.
Collapse
Affiliation(s)
- Toby Williams
- Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough University, Wolfson Building, Ashby Road, Loughborough, Leicestershire, LE11 3TU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Kaddour Bouazza-Marouf
- Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Loughborough universtiy, Wolfson Building, Ashby Road, Loughborough, Leicestershire, LE11 3TU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Massimiliano Zecca
- Wolfson School of Mechanical, Electrical, and Manufacturing Engineering, Loughborough University, Michael Pearson (East), 1 Oakwood Drive, Loughborough University Science and Enterprise Park, Loughborough, Leicestershire, LE11 3QF, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Alex Green
- Nuffield Department of Surgical Sciences, University of Oxford, University of Oxford, Oxford, Oxfordshire, OX3 9DU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| |
Collapse
|
12
|
Shi Y, Wu Y, Wang M, Tian Z, Kong X, He X. Sparse image reconstruction of intracerebral hemorrhage with electrical impedance tomography. J Med Imaging (Bellingham) 2021; 8:014501. [PMID: 33457443 DOI: 10.1117/1.jmi.8.1.014501] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 12/22/2020] [Indexed: 12/12/2022] Open
Abstract
Purpose: Intracerebral hemorrhage (ICH) is a common disease that is known for its high morbidity, high mortality, and high disability. The fast and accurate detection of ICH is essential for the acute care of patients. Electrical impedance tomography (EIT) offers an alternative with which pathological tissues can be detected by reconstructing conductivity variation. Nevertheless, the sensitive field of EIT is greatly affected by medium distribution, which is referred to as soft-field effect. In addition, the image reconstruction is a severely ill-posed inverse problem. Furthermore, due to the low conductivity of skull, the sensitivity in the sensing area is extremely low. Therefore, the reconstruction of ICH with EIT is great challenge. Approach: A sparse image reconstruction method is proposed for EIT to visualize the conductivity variation caused by ICH. To reduce the impact of soft-field effect, the normalization of sensitivity distribution is conducted for monolayer and three-layer head model. In addition, a constrained sparse L 1 -norm minimization model is developed for the image reconstruction. Augmented Lagrangian multiplier method and alternating minimization scheme are adopted to solve the proposed model. Results: The results show that the sensitivity in the sensing area is largely enhanced. Numerical simulation based on monolayer head model and three-layer head model is respectively carried out. Both the reconstructed images and the quantitative evaluations show that image reconstructed by the proposed method is much better than that reconstructed by traditional Tikhonov method. The reconstructions evaluated under the impact of noise also show that the proposed method has superior anti-noise performance. Conclusions: With the proposed method, the quality of the reconstructed image would be greatly improved. It is an effective approach for imaging ICH with EIT technique.
Collapse
Affiliation(s)
- Yanyan Shi
- Henan Normal University, Department of Electronic and Electrical Engineering, Xinxiang, China.,Fourth Military Medical University, College of Biomedical Engineering, Xi'an, China
| | - Yuehui Wu
- Henan Normal University, Department of Electronic and Electrical Engineering, Xinxiang, China
| | - Meng Wang
- Henan Normal University, Department of Electronic and Electrical Engineering, Xinxiang, China
| | - Zhiwei Tian
- Henan Normal University, Department of Electronic and Electrical Engineering, Xinxiang, China
| | - Xiaolong Kong
- Henan Normal University, Department of Electronic and Electrical Engineering, Xinxiang, China
| | - Xiaoyue He
- Henan Normal University, Department of Electronic and Electrical Engineering, Xinxiang, China
| |
Collapse
|
13
|
Li H, Liu X, Xu C, Yang B, Fu D, Dong X, Fu F. Managing erroneous measurements of dynamic brain electrical impedance tomography after reconnection of faulty electrodes. Physiol Meas 2020; 41:035002. [PMID: 32000152 DOI: 10.1088/1361-6579/ab71f4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Electrode detachment may occur during dynamic brain electrical impedance tomography (EIT) measurements. After the faulty electrodes have been reset, EIT can restore to steady monitoring but the corrupted data, which will challenge interpretation of the results, are notoriously difficult to recover. APPROACH Here, a piecewise processing method (PPM) is introduced to manage the erroneous EIT data after reattachment of faulty electrodes. In the PPM, we define the three phases before, during and after reconnection of the faulty electrode as PI, PII and PIII, respectively. Using this definition, an empirical mode decomposition-based interpolation method is introduced to compensate the corrupted data in PII, using the valid measurements in PI and PIII. Then, the compensated data in PII are spliced at the end of PI. Thus, there will be a surge at the junction of PII and PIII due to the changes in contact state of the repositioned electrodes. Finally, to ensure all the EIT data are obtained under constant electrode settings, we calculate the above changes and eliminate them from the data after PII. To verify the performance of the PPM, experiments based on head models, with anatomical structures and with human subjects were conducted. Metrics including permutation entropy (PE) and image correlation (IC) were proposed to measure the stability of the signal and the quality of the reconstructed EIT images, respectively. MAIN RESULTS The results demonstrated that the PE of the processed data was reduced to 0.25 and the IC improved to 0.78. SIGNIFICANCE Without iterative calculations the PPM could efficiently manage the erroneous EIT data after reattachment of the faulty electrodes.
Collapse
Affiliation(s)
- Haoting Li
- Haoting Li and Xuechao Liu contributed equally to this work
| | | | | | | | | | | | | |
Collapse
|
14
|
Liu J, Li Y, Lin Y, Meng Z, Guo X, Yu Y, Ma Z. Quantitative research on the interaction between cerebral edema and peripheral cerebral blood perfusion using swept-source optical coherence tomography. Quant Imaging Med Surg 2020; 11:939-947. [PMID: 33654667 DOI: 10.21037/qims-20-821] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Background Ischemic cerebral edema (CE) is a major leading cause of death in patients with ischemic stroke. The CE progression is closely related to the local cerebral blood perfusion (LCBP) level surrounding the edema area. Quantitative studying the interaction between the CE and peripheral LCBP may provide new inspiration for control and even treatment of CE. Methods Photothrombosis ischemia mouse model was established and observed for 9 hours using swept-source optical coherence tomography (SS-OCT). OCT-based angiography and OCT-based attenuation imaging techniques were used to reconstruct the angiograms reflecting the cerebral blood perfusion (CBP) level and optical attenuation coefficient (OAC) maps reflecting the edema state. The influence of edema on LCBP was analyzed by quantifying the blood perfusion in different spatial locations around the edema tissue, and the influence of LCBP on CE progression was revealed by comparing the changes of the edema area and LCBP level over time. Results Preliminary studies show that the effect of edema tissue on LCBP is very significant, which shows a clear spatial dependence. LCBP near the edema tissue is 15-20% lower than that far away from the edema tissue. When the LCBP drops to around 60% of the initial value, the edema area increases sharply. In addition, the level of CBP in the contralateral hemisphere also decreases with time. When the contralateral CBP drops to around 60%, there is a certain probability that contralateral edema will occur. Conclusions CE progression is not only related to the LCBP around the edema tissue but also related to the CBP of non-edematous regions. Controlling the CBP level of non-edematous regions may play a positive role in the treatment of CE. This work provides a new method and inspiration for exploring the mechanism of ischemic CE progression.
Collapse
Affiliation(s)
- Jian Liu
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Yan Li
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Yang Lin
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Ziyue Meng
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Xuyang Guo
- Department of Bioengineering, University of Washington, Seattle, USA
| | - Yao Yu
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Zhenhe Ma
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| |
Collapse
|
15
|
Real-Time Detection of Hemothorax and Monitoring its Progression in a Piglet Model by Electrical Impedance Tomography: A Feasibility Study. BIOMED RESEARCH INTERNATIONAL 2020; 2020:1357160. [PMID: 32190646 PMCID: PMC7064861 DOI: 10.1155/2020/1357160] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2019] [Revised: 01/12/2020] [Accepted: 01/22/2020] [Indexed: 12/20/2022]
Abstract
Hemothorax is a serious medical condition that can be life-threatening if left untreated. Early diagnosis and timely treatment are of great importance to produce favorable outcome. Although currently available diagnostic techniques, e.g., chest radiography, ultrasonography, and CT, can accurately detect hemothorax, delayed hemothorax cannot be identified early because these examinations are often performed on patients until noticeable symptoms manifest. Therefore, for early detection of delayed hemothorax, real-time monitoring by means of a portable and noninvasive imaging technique is needed. In this study, we employed electrical impedance tomography (EIT) to detect the onset of hemothorax in real time on eight piglet hemothorax models. The models were established by injection of 60 ml fresh autologous blood into the pleural cavity, and the subsequent development of hemothorax was monitored continuously. The results showed that EIT was able to sensitively detect hemothorax as small as 10 ml in volume, as well as its location. Also, the development of hemothorax over a range of 10 ml up to 60 ml was well monitored in real time, with a favorable linear relationship between the impedance change in EIT images and the volume of blood injected. These findings demonstrated that EIT has a unique potential for early diagnosis and continuous monitoring of hemothorax in clinical practice, providing medical staff valuable information for prompt identification and treatment of delayed hemothorax.
Collapse
|
16
|
Cao L, Li H, Fu D, Liu X, Ma H, Xu C, Dong X, Yang B, Fu F. Real-time imaging of infarction deterioration after ischemic stroke in rats using electrical impedance tomography. Physiol Meas 2020; 41:015004. [PMID: 31918414 DOI: 10.1088/1361-6579/ab69ba] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
OBJECTIVE This study investigated the feasibility of electrical impedance tomography (EIT) for monitoring the deterioration of ischemic lesion after the onset of stroke. APPROACH Fifteen rats were randomly distributed into two groups: rats operated to establish a right middle cerebral artery occlusion (MCAO) (n = 10), and sham-operated rats (n = 5). Then, the operated rats were kept 2 h under anesthesia for EIT monitoring. Subsequently, descriptive statistical analysis was performed on whole-brain resistivity changes, and repeated-measures analysis of variance (ANOVA) on the average resistivity variation index. Additionally, pathological examinations were performed after 6 h of infarction. MAIN RESULTS The results obtained showed that ischemic damage developed in the right corpus striatum of the rats with MCAO, whereas the brains of the sham group showed no anomalies. The descriptive statistical analysis revealed that the whole-brain resistivity changes after 30, 60, 90, and 120 min of infarction were 0.063 ± 0.038, 0.097 ± 0.046, 0.141 ± 0.062, and 0.204 ± 0.092 for the rats with MCAO and 0.029 ± 0.021, 0.002 ± 0.002, 0.017 ± 0.011, and -0.001 ± 0.011 for the sham-operated rats, respectively. The repeated-measures ANOVA revealed that the right MCAO model resulted in a significant impedance increase in the right hemisphere, which continued to increase over time after infarction. SIGNIFICANCE The overall study results indicate that EIT facilitates monitoring of local impedance variations caused by MCAO and may be a solution for real-time monitoring of intracranial pathological changes in ischemic stroke patients.
Collapse
Affiliation(s)
- Lu Cao
- Lu Cao and Haoting Li contributed equally to this work
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Liu J, Li Y, Yu Y, Yuan X, Lv H, Liu L, Zhao Y, Wang Y, Ma Z. Simultaneous detection of cerebral blood perfusion and cerebral edema using swept-source optical coherence tomography. JOURNAL OF BIOPHOTONICS 2020; 13:e201960087. [PMID: 31702865 DOI: 10.1002/jbio.201960087] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2019] [Revised: 10/21/2019] [Accepted: 11/06/2019] [Indexed: 06/10/2023]
Abstract
The progression of ischemic cerebral edema (CE) is closely related to the level of cerebral blood perfusion (CBP) and affects each other. Simultaneous detection of CBP and CE is helpful in understanding the mechanisms of ischemic CE development. In this article, a wide field of view swept-source optical coherence tomography system was used to detect CE status and CBP levels simultaneously in middle cerebral artery occlusion rats. Images reflecting these two physiological states can be reconstructed with only one C-scan. We quantify these two physiological states into four parameters, which contain two vascular parameters (vascular displacement distance and vascular perfusion density) and two edema parameters (optical attenuation coefficient and edema area). The association between the two vascular parameters and the two edema parameters was analyzed. The results show that there is a strong linear relationship between blood flow parameters and edema parameters. This work provides a new option for CE in vivo detection, and is very likely to play an important role in the development of relevant drugs or in selection of treatment options.
Collapse
Affiliation(s)
- Jian Liu
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Yan Li
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Yao Yu
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Xincheng Yuan
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Hongyu Lv
- Department of Ophthalmology, Maternal and Child Health Hospital, Qinhuangdao, China
| | - Lanxiang Liu
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Yuqian Zhao
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Yi Wang
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Zhenhe Ma
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| |
Collapse
|
18
|
Liu J, Li Y, Yu Y, Yuan X, Lv H, Zhao Y, Ma Z. Cerebral edema detection in vivo after middle cerebral artery occlusion using swept-source optical coherence tomography. NEUROPHOTONICS 2019; 6:045007. [PMID: 31720312 PMCID: PMC6835117 DOI: 10.1117/1.nph.6.4.045007] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 10/14/2019] [Indexed: 06/10/2023]
Abstract
Cerebral edema is a severe complication of ischemic cerebrovascular disease, which can lead to microcirculation compression resulting in additional ischemic damage. Real-time and continuous in vivo imaging techniques for edema detection are of great significance to basic research on cerebral edema. We attempted to monitor the cerebral edema status in rats with middle cerebral artery occlusion (MCAO) over time, using a wide field-of-view swept-source optical coherence tomography (SS-OCT) system. Optical attenuation coefficients (OACs) were calculated by an optimized depth-resolved estimation method, and en face OAC maps covering the whole cortex were obtained. Then, the tissue affected by edema was segmented from the OAC maps, and the cortical area affected by edema was estimated. Both magnetic resonance image (MRI) and brain water content measurements were used to verify the presence of cerebral edema. The results showed that the average OAC of the ischemic area gradually decreased as cerebral edema progressed, and the edema area detected by SS-OCT had high similarity in position and shape to that obtained by MRI. This work extends the application of OCT and provides an option for detecting cerebral edema in vivo after ischemic stroke.
Collapse
Affiliation(s)
- Jian Liu
- Northeastern University at Qinhuangdao, School of Control Engineering, Qinhuangdao, China
| | - Yan Li
- Northeastern University at Qinhuangdao, School of Control Engineering, Qinhuangdao, China
| | - Yao Yu
- Northeastern University at Qinhuangdao, School of Control Engineering, Qinhuangdao, China
| | - Xincheng Yuan
- University of Michigan, Department of Biomedical Engineering, Ann Arbor, Michigan, United States
| | - Hongyu Lv
- Maternal and Child Health Hospital, Department of Ophthalmology, Qinhuangdao, China
| | - Yuqian Zhao
- Northeastern University at Qinhuangdao, School of Control Engineering, Qinhuangdao, China
| | - Zhenhe Ma
- Northeastern University at Qinhuangdao, School of Control Engineering, Qinhuangdao, China
| |
Collapse
|
19
|
Liu J, Ding N, Yu Y, Liu L, Yuan X, Lv H, Zhao Y, Ma Z. Whole-brain microcirculation detection after ischemic stroke based on swept-source optical coherence tomography. JOURNAL OF BIOPHOTONICS 2019; 12:e201900122. [PMID: 31095859 DOI: 10.1002/jbio.201900122] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 05/11/2019] [Accepted: 05/15/2019] [Indexed: 06/09/2023]
Abstract
The occurrence and development of ischemic stroke are closely related to cerebral blood flow. Real-time monitoring of cerebral perfusion level is very useful for understanding the mechanisms of the disease. A wide field of view (FOV) is conducive to capturing lesions and observing the progression of the disease. In this paper, we attempt to monitor the whole-brain microcirculation in middle cerebral artery occlusion (MCAO) rats over time using a wide FOV swept-source OCT (SS-OCT) system. A constrained image registration algorithm is used to remove motion artifacts that are prone to occur in a wide FOV angiography. During ischemia, cerebral perfusion levels in the left and right hemispheres, as well as in the whole brain were quantified and compared. Changes in the shape and location of blood vessels were also recorded. The results showed that the trend in cerebral perfusion levels of both hemispheres was highly consistent during MCAO, and the position of the blood vessels varied over time. This work will provide new insights of ischemic stroke and is helpful to assess the effectiveness of potential treatment strategies.
Collapse
Affiliation(s)
- Jian Liu
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Ning Ding
- School of Sino-Dutch Biomedical and Information Engineering, Northeastern University, Shenyang, China
| | - Yao Yu
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Lanxiang Liu
- Department of Magnetic Resonance Imaging, Qinhuangdao Municipal No. 1 Hospital, Qinhuangdao, China
| | - Xincheng Yuan
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan
| | - Hongyu Lv
- Department of Ophthalmology, Maternal and Child Health Hospital, Qinhuangdao, China
| | - Yuqian Zhao
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| | - Zhenhe Ma
- School of Control Engineering, Northeastern University at Qinhuangdao, Qinhuangdao, China
| |
Collapse
|
20
|
Yang B, Li B, Xu C, Hu S, Dai M, Xia J, Luo P, Shi X, Zhao Z, Dong X, Fei Z, Fu F. Comparison of electrical impedance tomography and intracranial pressure during dehydration treatment of cerebral edema. NEUROIMAGE-CLINICAL 2019; 23:101909. [PMID: 31284231 PMCID: PMC6612924 DOI: 10.1016/j.nicl.2019.101909] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Revised: 06/19/2019] [Accepted: 06/24/2019] [Indexed: 11/04/2022]
Abstract
Cerebral edema after brain injury can lead to brain damage and death if diagnosis and treatment are delayed. This study investigates the feasibility of employing electrical impedance tomography (EIT) as a non-invasive imaging tool for monitoring the development of cerebral edema, in which impedance imaging of the brain related to brain water content is compared with intracranial pressure (ICP). We enrolled forty patients with cerebral hemorrhage who underwent lateral external ventricular drain with intraventricular ICP and EIT monitoring for 3 h after initiation of dehydration treatment. The average reconstructed impedance value (ARV) calculated from EIT images was compared with ICP. Dehydration effects induced changes in ARV and ICP showed a close negative correlation in all patients, and the mean correlation reached R2 = 0.78 ± 0.16 (p < .001). A regression equation (R2 = 0.62, p < .001) was formulated from the total of measurement data. The 95% limits of agreement were − 6.13 to 6.13 mmHg. Adaptive clustering and variance analysis of normalized changes in ARV and ICP showed 92.5% similarity and no statistically significant differences (p > .05). Moreover, the sensitivity, specificity and area under the curve of changes in ICP >10 mmHg were 0.65, 0.73 and 0.70 respectively. The findings show that EIT can monitor changes in brain water content associated with cerebral edema, which could provide a real-time and non-invasive imaging tool for early identification of cerebral edema and the evaluation of mannitol dehydration. Changes in brain water content due to cerebral edema alter EIT and ICP simultaneously. EIT has a close negative correlation with ICP during changes in brain water content. Cerebral edema can be early identified by EIT for initiating timely therapy. The efficacy of dehydration can be evaluation by EIT for guiding personalized therapy. The results suggest EIT can monitor cerebral edema real-timely and non-invasively.
Collapse
Affiliation(s)
- Bin Yang
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China
| | - Bing Li
- Department of Neurosurgery, Xijing Hospital, Fourth Military Medical University, 710032 Xi'an, China
| | - Canhua Xu
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China
| | - Shijie Hu
- Department of Neurosurgery, Xijing Hospital, Fourth Military Medical University, 710032 Xi'an, China
| | - Meng Dai
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China
| | - Junying Xia
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China
| | - Peng Luo
- Department of Neurosurgery, Xijing Hospital, Fourth Military Medical University, 710032 Xi'an, China
| | - Xuetao Shi
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China; Institute of Technical Medicine, Furtwangen University, 78054 Villingen-Schwenningen, Germany
| | - Xiuzhen Dong
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China
| | - Zhou Fei
- Department of Neurosurgery, Xijing Hospital, Fourth Military Medical University, 710032 Xi'an, China.
| | - Feng Fu
- Department of Biomedical Engineering, Fourth Military Medical University, 710032 Xi'an, China.
| |
Collapse
|
21
|
Liu X, Li H, Ma H, Xu C, Yang B, Dai M, Dong X, Fu F. An iterative damped least-squares algorithm for simultaneously monitoring the development of hemorrhagic and secondary ischemic lesions in brain injuries. Med Biol Eng Comput 2019; 57:1917-1931. [PMID: 31250276 DOI: 10.1007/s11517-019-02003-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2018] [Accepted: 06/07/2019] [Indexed: 10/26/2022]
Abstract
Electrical impedance tomography (EIT) is a non-invasive and real-time imaging method that has the potential to be used for monitoring intracerebral hemorrhage (ICH). Recent studies have proposed that ischemia secondary to ICH occurs simultaneously in the brain. Real-time monitoring of the development of hemorrhage and risk of secondary ischemia is crucial for clinical intervention. However, few studies have explored the performance of EIT monitoring in cases where hemorrhage and secondary ischemia exist. When these lesions get close to each other, or their conductivity and volume changes differ greatly, it becomes challenging for dynamic EIT algorithms to simultaneously reconstruct subtle injuries. To address this, an iterative damped least-squares (IDLS) algorithm is proposed in this study. The quality of the IDLS algorithm was assessed using blur radius and temporal response during computer simulation and a phantom 3D head-shaped model where bidirectional disturbance targets were simulated. The results showed that the IDLS algorithm enhanced contrast and concurrently reconstructed bidirectional disturbance targets in images. Moreover, it showed superior performance in decreasing the blur radius and was time cost-effective. With further improvement, the IDLS algorithm has the potential to be used for monitoring the development of hemorrhage and risk of ischemia secondary to ICH. Graphical abstract (a) and (b) are simulation images of bidirectional disturbance targets with different change ratios of volume (Vr) and conductivity (σr) based on the damped least-squares (DLS) algorithm and iterative damped least-squared (IDLS) algorithm, respectively. (c) shows the performance metrics of blur radius and temporal response with different volume ratio (corresponding to Vr). (d) shows the performance metrics of blur radius and temporal response with different conductivity change percentage (corresponding to σr).
Collapse
Affiliation(s)
- Xuechao Liu
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China
| | - Haoting Li
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China
| | - Hang Ma
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China
| | - Canhua Xu
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China
| | - Bin Yang
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China
| | - Meng Dai
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China
| | - Xiuzhen Dong
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China
| | - Feng Fu
- Department of Biomedical Engineering, Air Force Military Medical University, Xi'an, China.
| |
Collapse
|
22
|
Yang J, Zhao H, Li G, Ran Q, Chen J, Bai Z, Jin G, Sun J, Xu J, Qin M, Chen M. An experimental study on the early diagnosis of traumatic brain injury in rabbits based on a noncontact and portable system. PeerJ 2019; 7:e6717. [PMID: 30997290 PMCID: PMC6463870 DOI: 10.7717/peerj.6717] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Accepted: 03/05/2019] [Indexed: 12/21/2022] Open
Abstract
Closed cerebral hemorrhage (CCH) is a common symptom in traumatic brain injury (TBI) patients who suffer intracranial hemorrhage with the dura mater remaining intact. The diagnosis of CCH patients prior to hospitalization and in the early stage of the disease can help patients get earlier treatments that improve outcomes. In this study, a noncontact, portable system for early TBI-induced CCH detection was constructed that measures the magnetic induction phase shift (MIPS), which is associated with the mean brain conductivity caused by the ratio between the liquid (blood/CSF and the intracranial tissues) change. To evaluate the performance of this system, a rabbit CCH model with two severity levels was established based on the horizontal biological impactor BIM-II, whose feasibility was verified by computed tomography images of three sections and three serial slices. There were two groups involved in the experiments (group 1 with 10 TBI rabbits were simulated by hammer hit with air pressure of 600 kPa by BIM-II and group 2 with 10 TBI rabbits were simulated with 650 kPa). The MIPS values of the two groups were obtained within 30 min before and after injury. In group 1, the MIPS values showed a constant downward trend with a minimum value of −11.17 ± 2.91° at the 30th min after 600 kPa impact by BIM-II. After the 650 kPa impact, the MIPS values in group 2 showed a constant downward trend until the 25th min, with a minimum value of −16.81 ± 2.10°. Unlike group 1, the MIPS values showed an upward trend after that point. Before the injury, the MIPS values in both group 1 and group 2 did not obviously change within the 30 min measurement. Using a support vector machine at the same time point after injury, the classification accuracy of the two types of severity was shown to be beyond 90%. Combined with CCH pathological mechanisms, this system can not only achieve the detection of early functional changes in CCH but can also distinguish different severities of CCH.
Collapse
Affiliation(s)
- Jun Yang
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| | - Hui Zhao
- State Key Laboratory of Trauma, Burns and Combined Injury, Institute of Surgery Research, Third Military Medical University, Chongqing, China
| | - Gen Li
- Department of Biomedical Engineering, Chongqing University of Technology, Chongqing, China
| | - Qisheng Ran
- Department of Radiology, Army Medical Center, Chongqing, China
| | - Jingbo Chen
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| | - Zelin Bai
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| | - Gui Jin
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| | - Jian Sun
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| | - Jia Xu
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| | - Mingxin Qin
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| | - Mingsheng Chen
- College of Biomedical Engineering, Army Medical University, Chongqing, China
| |
Collapse
|
23
|
EIT Imaging of Intracranial Hemorrhage in Rabbit Models Is Influenced by the Intactness of Cranium. BIOMED RESEARCH INTERNATIONAL 2018; 2018:1321862. [PMID: 30581843 PMCID: PMC6276518 DOI: 10.1155/2018/1321862] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 10/26/2018] [Accepted: 11/11/2018] [Indexed: 11/17/2022]
Abstract
Electrical impedance tomography (EIT) has been shown to be a promising, bedside imaging method to monitor the progression of intracranial hemorrhage (ICH). However, the observed impedance changes within brain related to ICH differed among groups, and we hypothesized that the cranium intactness (open or closed) may be the one of potential reasons leading to the difference. Therefore, the aim of this study was to investigate this effect of open or closed cranium on impedance changes within brain in the rabbit ICH model. In this study, we first established the ICH model in 12 rabbits with the open cranium and in 12 rabbits with the closed cranium. Simultaneously, EIT measurements on the rabbits' heads were performed to record the impedance changes caused by injecting the autologous nonheparinized blood into cerebral parenchyma. Finally, the regional impedance changes on EIT images and the whole impedance changes were analyzed. It was surprisingly found that when the cranium was open, the impedance of the area where the blood was injected, as well as the whole brain impedance, decreased with the amount of blood being injected; when the cranium was closed, while the impedance of the area where blood was not injected continued to increase, the impedance of the area where blood was injected decreased within 20s of the blood being injected and then remained almost unchanged, and the whole brain impedance had a small fall and then notably increased. The results have validated that the cranium completeness (open or closed) has influences on impedance changes within brain when using EIT to monitor ICH. In future study on application of EIT to monitor ICH, the cranium completeness should be taken into account for establishing an ICH model and analyzing the corresponding EIT results.
Collapse
|
24
|
Optimal combination of electrodes and conductive gels for brain electrical impedance tomography. Biomed Eng Online 2018; 17:186. [PMID: 30572888 PMCID: PMC6302411 DOI: 10.1186/s12938-018-0617-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 12/12/2018] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is an emerging imaging technology that has been used to monitor brain injury and detect acute stroke. The time and frequency properties of electrode-skin contact impedance are important for brain EIT because brain EIT measurement is performed over a long period when used to monitor brain injury, and is carried out across a wide range of frequencies when used to detect stroke. To our knowledge, no study has simultaneously investigated the time and frequency properties of both electrode and conductive gel for brain EIT. METHODS In this study, the contact impedance of 16 combinations consisting of 4 kinds of clinical electrode and five types of commonly used conductive gel was measured on ten volunteers' scalp for a period of 1 h at frequencies from 100 Hz to 1 MHz using the two-electrode method. And then the performance of each combination was systematically evaluated in terms of the magnitude of contact impedance, and changes in contact impedance with time and frequency. RESULTS Results showed that combination of Ag+/Ag+Cl- powder electrode and low viscosity conductive gel performed best overall (Ten 20® in this study); it had a relatively low magnitude of contact impedance and superior performance regarding contact impedance with time (p < 0.05) and frequency (p < 0.05). CONCLUSIONS Experimental results indicates that the combination of Ag+/Ag+Cl- powder electrode and low viscosity conductive gel may be the best choice for brain EIT.
Collapse
|
25
|
Goren N, Avery J, Dowrick T, Mackle E, Witkowska-Wrobel A, Werring D, Holder D. Multi-frequency electrical impedance tomography and neuroimaging data in stroke patients. Sci Data 2018; 5:180112. [PMID: 29969115 PMCID: PMC6029572 DOI: 10.1038/sdata.2018.112] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Accepted: 04/16/2018] [Indexed: 11/26/2022] Open
Abstract
Electrical Impedance Tomography (EIT) is a non-invasive imaging technique, which has the potential to expedite the differentiation of ischaemic or haemorrhagic stroke, decreasing the time to treatment. Whilst demonstrated in simulation, there are currently no suitable imaging or classification methods which can be successfully applied to human stroke data. Development of these complex methods is hindered by a lack of quality Multi-Frequency EIT (MFEIT) data. To address this, MFEIT data were collected from 23 stroke patients, and 10 healthy volunteers, as part of a clinical trial in collaboration with the Hyper Acute Stroke Unit (HASU) at University College London Hospital (UCLH). Data were collected at 17 frequencies between 5 Hz and 2 kHz, with 31 current injections, yielding 930 measurements at each frequency. This dataset is the most comprehensive of its kind and enables combined analysis of MFEIT, Electroencephalography (EEG) and Computed Tomography (CT) or Magnetic Resonance Imaging (MRI) data in stroke patients, which can form the basis of future research into stroke classification.
Collapse
Affiliation(s)
- Nir Goren
- Medical Physics & Biomedical Engineering, University College London, London WC1E 6BT, UK
| | - James Avery
- Medical Physics & Biomedical Engineering, University College London, London WC1E 6BT, UK
| | - Thomas Dowrick
- Medical Physics & Biomedical Engineering, University College London, London WC1E 6BT, UK
| | - Eleanor Mackle
- Medical Physics & Biomedical Engineering, University College London, London WC1E 6BT, UK
| | - Anna Witkowska-Wrobel
- Medical Physics & Biomedical Engineering, University College London, London WC1E 6BT, UK
| | - David Werring
- Stroke Research Centre, Department of Brain repair and Rehabilitation, University College London Institute of Neurology, London WC1N 3BG, UK
| | - David Holder
- Medical Physics & Biomedical Engineering, University College London, London WC1E 6BT, UK
| |
Collapse
|
26
|
Electrical Impedance Changes at Different Phases of Cerebral Edema in Rats with Ischemic Brain Injury. BIOMED RESEARCH INTERNATIONAL 2018; 2018:9765174. [PMID: 29967792 PMCID: PMC6009021 DOI: 10.1155/2018/9765174] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 04/16/2018] [Accepted: 04/22/2018] [Indexed: 11/28/2022]
Abstract
Cerebral edema contributes significantly to the morbidity and mortality associated with many common neurologic conditions. Clinically, a diagnostic tool that can be used to monitor cerebral edema in real-time and differentiate between different types of cerebral edema is urgently needed. Because there are differences in electrical impedance between normal cortical tissue and cerebral edema tissue, electrical impedance tomography (EIT) can potentially be used to detect cerebral edema. Accurate recording of the electrical impedance properties of cerebral edema tissue at different time points is important when detecting cerebral edema with EIT. In this study, a rat cerebral edema model was established; then, following the onset of ischemic brain injury, variation in the electrical impedance of cerebral edema was measured at different time points within a 24-hour period and the corresponding morphologic variation was analyzed. After the first six hours, following the onset of ischemic brain injury, the resistivity of brain tissue increased (p < 0.05); during this period, brain cell volume increased (p < 0.05) and the intercellular space decreased (p < 0.05) (behaving like cytotoxic cerebral edema). From 6 to 24 hours, the resistivity of brain tissue decreased; during this time, brain cell volume unchanged (p > 0.05) while intercellular space increased (p < 0.05) (behaving like vasogenic cerebral edema). These findings support the notion that EIT can be used to monitor the development of cerebral edema in real-time and differentiate between different types of brain edema.
Collapse
|
27
|
Candefjord S, Winges J, Malik AA, Yu Y, Rylander T, McKelvey T, Fhager A, Elam M, Persson M. Microwave technology for detecting traumatic intracranial bleedings: tests on phantom of subdural hematoma and numerical simulations. Med Biol Eng Comput 2017; 55:1177-1188. [PMID: 27738858 PMCID: PMC5544814 DOI: 10.1007/s11517-016-1578-6] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Accepted: 09/21/2016] [Indexed: 11/28/2022]
Abstract
Traumatic brain injury is the leading cause of death and severe disability for young people and a major public health problem for elderly. Many patients with intracranial bleeding are treated too late, because they initially show no symptoms of severe injury and are not transported to a trauma center. There is a need for a method to detect intracranial bleedings in the prehospital setting. In this study, we investigate whether broadband microwave technology (MWT) in conjunction with a diagnostic algorithm can detect subdural hematoma (SDH). A human cranium phantom and numerical simulations of SDH are used. Four phantoms with SDH 0, 40, 70 and 110 mL are measured with a MWT instrument. The simulated dataset consists of 1500 observations. Classification accuracy is assessed using fivefold cross-validation, and a validation dataset never used for training. The total accuracy is 100 and 82-96 % for phantom measurements and simulated data, respectively. Sensitivity and specificity for bleeding detection were 100 and 96 %, respectively, for the simulated data. SDH of different sizes is differentiated. The classifier requires training dataset size in order of 150 observations per class to achieve high accuracy. We conclude that the results indicate that MWT can detect and estimate the size of SDH. This is promising for developing MWT to be used for prehospital diagnosis of intracranial bleedings.
Collapse
Affiliation(s)
- Stefan Candefjord
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden.
- MedTech West, Sahlgrenska University Hospital, Röda Stråket 10 B, 413 45, Gothenburg, Sweden.
- SAFER Vehicle and Traffic Safety Centre at Chalmers, Gothenburg, Sweden.
| | - Johan Winges
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden
| | - Ahzaz Ahmad Malik
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden
| | - Yinan Yu
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden
- MedTech West, Sahlgrenska University Hospital, Röda Stråket 10 B, 413 45, Gothenburg, Sweden
| | - Thomas Rylander
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden
| | - Tomas McKelvey
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden
- MedTech West, Sahlgrenska University Hospital, Röda Stråket 10 B, 413 45, Gothenburg, Sweden
| | - Andreas Fhager
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden
- MedTech West, Sahlgrenska University Hospital, Röda Stråket 10 B, 413 45, Gothenburg, Sweden
| | - Mikael Elam
- MedTech West, Sahlgrenska University Hospital, Röda Stråket 10 B, 413 45, Gothenburg, Sweden
- Clinical Neurophysiology, Sahlgrenska University Hospital, Blå Stråket 5, 413 45, Gothenburg, Sweden
| | - Mikael Persson
- Department of Signals and Systems, Chalmers University of Technology, 412 96, Gothenburg, Sweden
- MedTech West, Sahlgrenska University Hospital, Röda Stråket 10 B, 413 45, Gothenburg, Sweden
| |
Collapse
|
28
|
Avery J, Aristovich K, Low B, Holder D. Reproducible 3D printed head tanks for electrical impedance tomography with realistic shape and conductivity distribution. Physiol Meas 2017; 38:1116-1131. [PMID: 28530209 DOI: 10.1088/1361-6579/aa6586] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Electrical impedance tomography (EIT) has many promising applications in brain injury monitoring. To evaluate both instrumentation and reconstruction algorithms, experiments are first performed in head tanks. Existing methods, whilst accurate, produce a discontinuous conductivity, and are often made by hand, making it hard for other researchers to replicate. APPROACH We have developed a method for constructing head tanks directly in a 3D printer. Conductivity was controlled through perforations in the skull surface, which allow for saline to pass through. Varying the diameter of the holes allowed for the conductivity to be controlled with 3% error for the target conductivity range. Taking CT and MRI segmentations as a basis, this method was employed to create an adult tank with a continuous conductivity distribution, and a neonatal tank with fontanelles. MAIN RESULTS Using 3D scanning a geometric accuracy of 0.21 mm was recorded, equal to that of the precision of the 3D printer used. Differences of 6.1% ± 6.4% (n = 11 in 4 tanks) compared to simulations were recorded in c. 800 boundary voltages. This may be attributed to the morphology of the skulls increasing tortuosity effects and hole misalignment. Despite significant differences in errors between three repetitions of the neonatal tank, images of a realistic perturbation could still be reconstructed with different tanks used for the baseline and perturbation datasets. SIGNIFICANCE These phantoms can be reproduced by any researcher with access to a 'hobbyist' 3D printer in a matter of days. All design files have been released using an open source license to encourage reproduction and modification.
Collapse
|
29
|
In Vivo Bioimpedance Spectroscopy Characterization of Healthy, Hemorrhagic and Ischemic Rabbit Brain within 10 Hz-1 MHz. SENSORS 2017; 17:s17040791. [PMID: 28387710 PMCID: PMC5422064 DOI: 10.3390/s17040791] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 03/30/2017] [Accepted: 04/04/2017] [Indexed: 12/13/2022]
Abstract
Acute stroke is a serious cerebrovascular disease and has been the second leading cause of death worldwide. Conventional diagnostic modalities for stroke, such as CT and MRI, may not be available in emergency settings. Hence, it is imperative to develop a portable tool to diagnose stroke in a timely manner. Since there are differences in impedance spectra between normal, hemorrhagic and ischemic brain tissues, multi-frequency electrical impedance tomography (MFEIT) shows great promise in detecting stroke. Measuring the impedance spectra of healthy, hemorrhagic and ischemic brain in vivo is crucial to the success of MFEIT. To our knowledge, no research has established hemorrhagic and ischemic brain models in the same animal and comprehensively measured the in vivo impedance spectra of healthy, hemorrhagic and ischemic brain within 10 Hz–1 MHz. In this study, the intracerebral hemorrhage and ischemic models were established in rabbits, and then the impedance spectra of healthy, hemorrhagic and ischemic brain were measured in vivo and compared. The results demonstrated that the impedance spectra differed significantly between healthy and stroke-affected brain (i.e., hemorrhagic or ischemic brain). Moreover, the rate of change in brain impedance following hemorrhagic and ischemic stroke with regard to frequency was distinct. These findings further validate the feasibility of using MFEIT to detect stroke and differentiate stroke types, and provide data supporting for future research.
Collapse
|
30
|
Avery J, Dowrick T, Faulkner M, Goren N, Holder D. A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System. SENSORS (BASEL, SWITZERLAND) 2017; 17:E280. [PMID: 28146122 PMCID: PMC5336119 DOI: 10.3390/s17020280] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Accepted: 01/25/2017] [Indexed: 11/16/2022]
Abstract
A highly versatile Electrical Impedance Tomography (EIT) system, nicknamed the ScouseTom, has been developed. The system allows control over current amplitude, frequency, number of electrodes, injection protocol and data processing. Current is injected using a Keithley 6221 current source, and voltages are recorded with a 24-bit EEG system with minimum bandwidth of 3.2 kHz. Custom PCBs interface with a PC to control the measurement process, electrode addressing and triggering of external stimuli. The performance of the system was characterised using resistor phantoms to represent human scalp recordings, with an SNR of 77.5 dB, stable across a four hour recording and 20 Hz to 20 kHz. In studies of both haeomorrhage using scalp electrodes, and evoked activity using epicortical electrode mats in rats, it was possible to reconstruct images matching established literature at known areas of onset. Data collected using scalp electrode in humans matched known tissue impedance spectra and was stable over frequency. The experimental procedure is software controlled and is readily adaptable to new paradigms. Where possible, commercial or open-source components were used, to minimise the complexity in reproduction. The hardware designs and software for the system have been released under an open source licence, encouraging contributions and allowing for rapid replication.
Collapse
Affiliation(s)
- James Avery
- Department Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK.
| | - Thomas Dowrick
- Department Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK.
| | - Mayo Faulkner
- Department Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK.
| | - Nir Goren
- Department Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK.
| | - David Holder
- Department Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK.
| |
Collapse
|
31
|
Noninvasive Brain Physiology Monitoring for Extreme Environments: A Critical Review. J Neurosurg Anesthesiol 2016; 27:318-28. [PMID: 25811362 DOI: 10.1097/ana.0000000000000175] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Our ability to monitor the brain physiology is advancing; however, most of the technology is bulky, expensive, and designed for traditional clinical settings. With long-duration space exploration, there is a need for developing medical technologies that are reliable, low energy, portable, and semiautonomous. Our aim was to review the state of the art for noninvasive technologies capable of monitoring brain physiology in diverse settings. A literature review of PubMed and the Texas Medical Center library sites was performed using prespecified search criteria to identify portable technologies for monitoring physiological aspects of the brain physiology. Most brain-monitoring technologies require a moderate to high degree of operator skill. Some are low energy, but many require a constant external power supply. Most of the technologies lack the accuracy seen in gold standard measures, due to the need for calibration, but may be useful for screening or monitoring relative changes in a parameter. Most of the technologies use ultrasound or electromagnetic radiation as energy sources. There is an important need for further development of portable technologies that can be operated in a variety of extreme environments to monitor brain health.
Collapse
|
32
|
Mahara A, Khan S, Murphy EK, Schned AR, Hyams ES, Halter RJ. 3D Microendoscopic Electrical Impedance Tomography for Margin Assessment During Robot-Assisted Laparoscopic Prostatectomy. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:1590-1601. [PMID: 25730825 DOI: 10.1109/tmi.2015.2407833] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Radially configured microendoscopic electrical impedance probes intended for intraoperative surgical margin assessment during robot-assisted laparoscopic prostatectomy (RALP) were examined through simulation, bench-top experimentation, and ex vivo tissue studies. Three probe designs with 8, 9, and 17 electrodes, respectively, were analyzed through finite element method based simulations. One mm diameter spherical inclusions ( σinclusion = 1 S/m) are positioned at various locations within a hemispherical background ( σbackground = 0.1 S/m) of radius 5 mm. An 8-electrode configuration is not able to localize the inclusion at these positions while 9 and 17-electrode configurations are able to accurately reconstruct the inclusion at maximum depth of 1 mm and 3 mm, respectively. All three probe designs were constructed and evaluated using saline phantoms and ex vivo porcine and human prostate tissues. The 17-electrode probe performed best in saline phantom studies, accurately reconstructing high contrast, 1-mm-diameter metal cylindrical inclusions in a saline bath ( σsaline = 0.1 S/m) with a position and area error of 0.46 mm and 0.84 mm2, respectively. Additionally, the 17-electrode probe was able to adequately distinguish cancerous from benign tissues in three ex vivo human prostates. Simulations, bench-top saline experiments, and ex vivo tissue sampling suggest that for intraoperative surgical margin assessment during RALP, the 17-electrode probe (as compared to an 8 and 9 electrode probe) will be necessary to provide sufficient accuracy and sensitivity.
Collapse
|
33
|
Pandin P, Renard M, Bianchini A, Desjardin P, Obbergh LV. Monitoring Brain and Spinal Cord Metabolism and Function. ACTA ACUST UNITED AC 2014. [DOI: 10.4236/ojanes.2014.46020] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|