1
|
Manfield J, Martin S, Green AL, FitzGerald JJ. Evaluation of 3D C-Arm Fluoroscopy versus Diagnostic CT for Deep Brain Stimulation Stereotactic Registration and Post-Operative Lead Localization. Stereotact Funct Neurosurg 2024; 102:195-202. [PMID: 38537625 DOI: 10.1159/000536017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Accepted: 12/09/2023] [Indexed: 06/05/2024]
Abstract
INTRODUCTION DBS efficacy depends on accuracy. CT-MRI fusion is established for both stereotactic registration and electrode placement verification. The desire to streamline DBS workflows, reduce operative time, and minimize patient transfers has increased interest in portable imaging modalities such as the Medtronic O-arm® and mobile CT. However, these remain expensive and bulky. 3D C-arm fluoroscopy (3DXT) units are a smaller and less costly alternative, albeit incompatible with traditional frame-based localization and without useful soft tissue resolution. We aimed to compare fusion of 3DXT and CT with pre-operative MRI to evaluate if 3DXT-MRI fusion alone is sufficient for accurate registration and reliable targeting verification. We further assess DBS targeting accuracy using a 3DXT workflow and compare radiation dosimetry between modalities. METHODS Patients underwent robot-assisted DBS implantation using a workflow incorporating 3DXT which we describe. Two intra-operative 3DXT spins were performed for registration and accuracy verification followed by conventional CT post-operatively. Post-operative 3DXT and CT images were independently fused to the same pre-operative MRI sequence and co-ordinates generated for comparison. Registration accuracy was compared to 15 consecutive controls who underwent CT-based registration. Radial targeting accuracy was calculated and radiation dosimetry recorded. RESULTS Data were obtained from 29 leads in 15 consecutive patients. 3DXT registration accuracy was significantly superior to CT with mean error 0.22 ± 0.03 mm (p < 0.0001). Mean Euclidean electrode tip position variation for CT to MRI versus 3DXT to MRI fusion was 0.62 ± 0.40 mm (range 0.0 mm-1.7 mm). In comparison, direct CT to 3DXT fusion showed electrode tip Euclidean variance of 0.23 ± 0.09 mm. Mean radial targeting accuracy assessed on 3DXT was 0.97 ± 0.54 mm versus 1.15 ± 0.55 mm on CT with differences insignificant (p = 0.30). Mean patient radiation doses were around 80% lower with 3DXT versus CT (p < 0.0001). DISCUSSION Mobile 3D C-arm fluoroscopy can be safely incorporated into DBS workflows for both registration and lead verification. For registration, the limited field of view requires the use of frameless transient fiducials and is highly accurate. For lead position verification based on MRI co-registration, we estimate there is around a 0.4 mm discrepancy between lead position seen on 3DXT versus CT when corrected for brain shift. This is similar to that described in O-arm® or mobile CT series. For units where logistical or financial considerations preclude the acquisition of a cone beam CT or mobile CT scanner, our data support portable 3D C-arm fluoroscopy as an acceptable alternative with significantly lower radiation exposure.
Collapse
Affiliation(s)
- James Manfield
- Oxford Functional Neurosurgery, John Radcliffe Hospital, Headley Way, Headington, Oxford, UK
| | - Sean Martin
- Oxford Functional Neurosurgery, John Radcliffe Hospital, Headley Way, Headington, Oxford, UK
| | - Alexander L Green
- Oxford Functional Neurosurgery, John Radcliffe Hospital, Headley Way, Headington, Oxford, UK
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK
| | - James J FitzGerald
- Oxford Functional Neurosurgery, John Radcliffe Hospital, Headley Way, Headington, Oxford, UK
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK
| |
Collapse
|
2
|
Delcont MR, Ou-Yang DC, Burger EL, Patel VV, Wessell NM, Kleck CJ. Alternative Uses of O-Arm and Stealth Navigation Technology Over 10 Years: The University of Colorado Experience. Orthopedics 2023; 46:e89-e97. [PMID: 35876781 DOI: 10.3928/01477447-20220719-04] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Intraoperative computed tomography scanning with O-arm and use of Stealth navigation can improve surgical outcomes in a variety of orthopedic subspecialties. In spine surgery, the accuracy, precision, and safety of pedicle screw and interbody implant placement has improved. This technology is now routinely used in percutaneous pedicle screw placement and minimally invasive sacroiliac joint fusion. Other applications include, but are not limited to, isthmic pars defect repair, lumbosacral pseudoarticulation resection in Bertolotti's syndrome, radiofrequency ablation, and en bloc tumor resection. Intraoperative navigation has numerous applications, and use of this technology should continue to evolve as the technology advances. [Orthopedics. 2023;46(2):e89-e97.].
Collapse
|
3
|
Uneri A, Wu P, Jones CK, Vagdargi P, Han R, Helm PA, Luciano MG, Anderson WS, Siewerdsen JH. Deformable 3D-2D registration for high-precision guidance and verification of neuroelectrode placement. Phys Med Biol 2021; 66. [PMID: 34644684 DOI: 10.1088/1361-6560/ac2f89] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 10/13/2021] [Indexed: 11/11/2022]
Abstract
Purpose.Accurate neuroelectrode placement is essential to effective monitoring or stimulation of neurosurgery targets. This work presents and evaluates a method that combines deep learning and model-based deformable 3D-2D registration to guide and verify neuroelectrode placement using intraoperative imaging.Methods.The registration method consists of three stages: (1) detection of neuroelectrodes in a pair of fluoroscopy images using a deep learning approach; (2) determination of correspondence and initial 3D localization among neuroelectrode detections in the two projection images; and (3) deformable 3D-2D registration of neuroelectrodes according to a physical device model. The method was evaluated in phantom, cadaver, and clinical studies in terms of (a) the accuracy of neuroelectrode registration and (b) the quality of metal artifact reduction (MAR) in cone-beam CT (CBCT) in which the deformably registered neuroelectrode models are taken as input to the MAR.Results.The combined deep learning and model-based deformable 3D-2D registration approach achieved 0.2 ± 0.1 mm accuracy in cadaver studies and 0.6 ± 0.3 mm accuracy in clinical studies. The detection network and 3D correspondence provided initialization of 3D-2D registration within 2 mm, which facilitated end-to-end registration runtime within 10 s. Metal artifacts, quantified as the standard deviation in voxel values in tissue adjacent to neuroelectrodes, were reduced by 72% in phantom studies and by 60% in first clinical studies.Conclusions.The method combines the speed and generalizability of deep learning (for initialization) with the precision and reliability of physical model-based registration to achieve accurate deformable 3D-2D registration and MAR in functional neurosurgery. Accurate 3D-2D guidance from fluoroscopy could overcome limitations associated with deformation in conventional navigation, and improved MAR could improve CBCT verification of neuroelectrode placement.
Collapse
Affiliation(s)
- A Uneri
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America
| | - P Wu
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America
| | - C K Jones
- Malone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD 21218, United States of America
| | - P Vagdargi
- Department of Computer Science, Johns Hopkins University, Baltimore, MD 21218, United States of America
| | - R Han
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America
| | - P A Helm
- Medtronic, Littleton, MA 01460, United States of America
| | - M G Luciano
- Department of Neurosurgery, Johns Hopkins Medicine, Baltimore, MD 21287, United States of America
| | - W S Anderson
- Department of Neurosurgery, Johns Hopkins Medicine, Baltimore, MD 21287, United States of America
| | - J H Siewerdsen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21205, United States of America.,Malone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, MD 21218, United States of America.,Department of Computer Science, Johns Hopkins University, Baltimore, MD 21218, United States of America.,Department of Neurosurgery, Johns Hopkins Medicine, Baltimore, MD 21287, United States of America
| |
Collapse
|
4
|
Validation of 3D fluoroscopy for image-guidance registration in depth electrode implantation for medically refractory epilepsy. Acta Neurochir (Wien) 2021; 163:1347-1354. [PMID: 33443679 DOI: 10.1007/s00701-021-04706-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 01/04/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND Frame registration is a critical step to ensure accurate electrode placement in stereotactic procedures such as stereoelectroencephalography (SEEG) and is routinely done by merging a computed tomography (CT) scan with the preoperative magnetic resonance (MR) examination. Three-dimensional fluoroscopy (XT) has emerged as a method for intraoperative electrode verification following electrode implantation and more recently has been proposed as a registration method with several advantages. METHODS We compared the accuracy of SEEG electrode placement by frame registration with CT and XT imaging by analyzing the Euclidean distance between planned and post-implantation trajectories of the SEEG electrodes to calculate the error in both the entry (EP) and target (TP) points. Other variables included radiation dose, efficiency, and complications. RESULTS Twenty-seven patients (13 CT and 14 XT) underwent placement of SEEG electrodes (319 in total). The mean EP and TP errors for the CT group were 2.3 mm and 3.3 mm, respectively, and 1.9 mm and 2.9 mm for the XT group, with no statistical difference (p = 0.75 and p = 0.246). The time to first electrode placement was similar (XT, 82 ± 10 min; CT, 84 ± 22 min; p = 0.858) and the average radiation exposure with XT (234 ± 55 mGy*cm) was significantly lower than CT (1245 ± 123 mGy*cm) (p < 0.0001). Four complications were documented with equal incidence in both groups. CONCLUSIONS The use of XT as a method for registration resulted in similar implantation accuracy compared with CT. Advantages of XT are the substantial reduction in radiation dose and the elimination of the need to transfer the patient out of the room which may have an impact on patient safety and OR efficiency.
Collapse
|
5
|
Philipp LR, Matias CM, Thalheimer S, Mehta SH, Sharan A, Wu C. Robot-Assisted Stereotaxy Reduces Target Error: A Meta-Analysis and Meta-Regression of 6056 Trajectories. Neurosurgery 2021; 88:222-233. [PMID: 33045739 DOI: 10.1093/neuros/nyaa428] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Accepted: 07/12/2020] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND The pursuit of improved accuracy for localization and electrode implantation in deep brain stimulation (DBS) and stereoelectroencephalography (sEEG) has fostered an abundance of disparate surgical/stereotactic practices. Specific practices/technologies directly modify implantation accuracy; however, no study has described their respective influence in multivariable context. OBJECTIVE To synthesize the known literature to statistically quantify factors affecting implantation accuracy. METHODS A systematic review and meta-analysis was conducted to determine the inverse-variance weighted pooled mean target error (MTE) of implanted electrodes among patients undergoing DBS or sEEG. MTE was defined as Euclidean distance between planned and final electrode tip. Meta-regression identified moderators of MTE in a multivariable-adjusted model. RESULTS A total of 37 eligible studies were identified from a search return of 2,901 potential articles (2002-2018) - 27 DBS and 10 sEEG. Random-effects pooled MTE = 1.91 mm (95% CI: 1.7-2.1) for DBS and 2.34 mm (95% CI: 2.1-2.6) for sEEG. Meta-regression identified study year, robot use, frame/frameless technique, and intraoperative electrophysiologic testing (iEPT) as significant multivariable-adjusted moderators of MTE (P < .0001, R2 = 0.63). Study year was associated with a 0.92-mm MTE reduction over the 16-yr study period (P = .0035), and robot use with a 0.79-mm decrease (P = .0019). Frameless technique was associated with a mean 0.50-mm (95% CI: 0.17-0.84) increase, and iEPT use with a 0.45-mm (95% CI: 0.10-0.80) increase in MTE. Registration method, imaging type, intraoperative imaging, target, and demographics were not significantly associated with MTE on multivariable analysis. CONCLUSION Robot assistance for stereotactic electrode implantation is independently associated with improved accuracy and reduced target error. This remains true regardless of other procedural factors, including frame-based vs frameless technique.
Collapse
Affiliation(s)
- Lucas R Philipp
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Caio M Matias
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Sara Thalheimer
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Shyle H Mehta
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Ashwini Sharan
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| | - Chengyuan Wu
- Department of Neurological Surgery, Thomas Jefferson University Hospitals, Philadelphia, Pennsylvania
| |
Collapse
|
6
|
Atsumi H, Matsumae M. Fusing of Preoperative Magnetic Resonance and Intraoperative O-arm Images in Deep Brain Stimulation Enhance Intuitive Surgical Planning and Increase Accuracy of Lead Placement. Neurol Med Chir (Tokyo) 2021; 61:341-346. [PMID: 33790132 PMCID: PMC8120096 DOI: 10.2176/nmc.tn.2020-0317] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Intraoperative fluoroscopy and microelectrode recording (MER) are useful techniques for guiding lead placement in deep brain stimulation (DBS). Recent advances in magnetic resonance imaging (MRI) have enabled information on the location of the basal ganglia, as the target of DBS, to be obtained preoperatively. However, intraoperative images with few artifacts are required to enable accurate fusion of preoperative imaging data with intraoperative lead position data. With our method, we first fuse preoperative MRI and pre-frame fixed computed tomography (CT) images, then fuse the CT images exactly after mounting the frame, using this fusion image as a platform image. Compared with before and after frame fixation, the pre-frame fixed CT has less artifacts, facilitating the identification of soft tissues such as the ventricles and cortical surface on pre-frame fixed CT images. By fusing the structural information for these soft tissues between pre-frame fixed CT and MR images, this fusion process can provide improved accuracy that is intuitively understood by the surgeon. Using platform images, surgical planning and intraoperative lead positioning can then be evaluated on the same coordinate axis. Positional data on the lead acquired as three-dimensional (3D) data are then added to the platform image. The proposed surgical steps permit the acquisition of accurate lead position data.
Collapse
Affiliation(s)
- Hideki Atsumi
- Department of Neurosurgery, Tokai University School of Medicine
| | | |
Collapse
|
7
|
Furlanetti L, Hasegawa H, Oviedova A, Raslan A, Samuel M, Selway R, Ashkan K. O-Arm Stereotactic Imaging in Deep Brain Stimulation Surgery Workflow: A Utility and Cost-Effectiveness Analysis. Stereotact Funct Neurosurg 2020; 99:93-106. [PMID: 33260175 DOI: 10.1159/000510344] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 07/21/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION Deep brain stimulation (DBS) surgery is an established treatment for movement disorders. Advances in neuroimaging techniques have resulted in improved targeting accuracy that may improve clinical outcomes. This study aimed to evaluate the safety and feasibility of using the Medtronic O-arm device for the acquisition of intraoperative stereotactic imaging, targeting, and localization of DBS electrodes compared with standard stereotactic MRI or computed tomography (CT). METHODS Patients were recruited prospectively into the study. Routine frame-based stereotactic DBS surgery was performed. Intraoperative imaging was used to facilitate and verify the accurate placement of the intracranial electrodes. The acquisition of coordinates and verification of the position of the electrodes using the O-arm were evaluated and compared with conventional stereotactic MRI or CT. Additionally, a systematic review of the literature on the use of intraoperative imaging in DBS surgery was performed. RESULTS Eighty patients were included. The indications for DBS surgery were dystonia, Parkinson's disease, essential tremor, and epilepsy. The globus pallidus internus was the most commonly targeted region (43.7%), followed by the subthalamic nucleus (35%). Stereotactic O-arm imaging reduced the overall surgical time by 68 min, reduced the length of time of acquisition of stereotactic images by 77%, reduced patient exposure to ionizing radiation by 24.2%, significantly reduced operating room (OR) costs per procedure by 31%, and increased the OR and neuroradiology suite availability. CONCLUSIONS The use of the O-arm in DBS surgery workflow significantly reduced the duration of image acquisition, the exposure to ionizing radiation, and costs when compared with standard stereotactic MRI or CT, without reducing accuracy.
Collapse
Affiliation(s)
- Luciano Furlanetti
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom,
| | - Harutomo Hasegawa
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Anna Oviedova
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Ahmed Raslan
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Michael Samuel
- Department of Neurology, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Richard Selway
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| | - Keyoumars Ashkan
- Department of Neurosurgery, King's College Hospital NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
8
|
Bolier E, Bot M, van den Munckhof P, Pal G, Sani S, Verhagen Metman L. The Medial Subthalamic Nucleus Border as a New Anatomical Reference in Stereotactic Neurosurgery for Parkinson's Disease. Stereotact Funct Neurosurg 2020; 99:187-195. [PMID: 33207350 DOI: 10.1159/000510802] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Accepted: 07/24/2020] [Indexed: 11/19/2022]
Abstract
INTRODUCTION The intersection of Bejjani's line with the well-delineated medial subthalamic nucleus (STN) border on MRI has recently been proposed as an individualized reference in subthalamic deep brain stimulation (DBS) surgery for Parkinson's disease (PD). We, therefore, aimed to investigate the applicability across centers of the medial STN border as a patient-specific reference point in STN DBS for PD and explore anatomical variability between left and right mesencephalic area within patients. Furthermore, we aim to evaluate a recently defined theoretic stimulation "hotspot" in a different center. METHODS Preoperative 3-Tesla T2 and susceptibility-weighted images (SWI) were used to identify the intersection of Bejjani's line with the medial STN border in left and right mesencephalic area. The average stereotactic coordinates of the center of stimulation relative to the medial STN border were compared with the predefined theoretic stimulation "hotspot." RESULTS Fifty-four patients provided 108 stereotactic coordinates of medial STN borders on both sequences. Significant difference in means was found in the Y-(anteroposterior) and Z-(dorsoventral) directions (T2 vs. SWI; p < 0.001). Mean coordinates in the Y-(anteroposterior) direction differed significantly between left and right mesencephalic area (T2: p < 0.001; SWI: p = 0.021). Sixty-six DBS leads were placed in 36 patients that had finished stimulation programming, and the average stereotactic coordinates of the center of stimulation relative to the medial STN border on T2 sequences were 3.1 mm lateral, 0.7 mm anterior, and 1.8 mm superior, in proximity of the predefined theoretic stimulation "hotspot." CONCLUSION The medial STN border is applicable across centers as a reference point for STN DBS surgery for PD and seems suitable in order to account for interindividual and intraindividual anatomical variability if one is aware of the discrepancies between T2-weighted imaging and SWI.
Collapse
Affiliation(s)
- Erik Bolier
- Department of Neurological Sciences, Rush University Medical Center, Chicago, Illinois, USA, .,Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center, Amsterdam, The Netherlands,
| | - Maarten Bot
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center, Amsterdam, The Netherlands
| | - Pepijn van den Munckhof
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center, Amsterdam, The Netherlands
| | - Gian Pal
- Department of Neurological Sciences, Rush University Medical Center, Chicago, Illinois, USA
| | - Sepehr Sani
- Department of Neurosurgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Leo Verhagen Metman
- Department of Neurological Sciences, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
9
|
Sharma VD, Patel M, Miocinovic S. Surgical Treatment of Parkinson's Disease: Devices and Lesion Approaches. Neurotherapeutics 2020; 17:1525-1538. [PMID: 33118132 PMCID: PMC7851282 DOI: 10.1007/s13311-020-00939-x] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/28/2020] [Indexed: 10/23/2022] Open
Abstract
Surgical treatments have transformed the management of Parkinson's disease (PD). Therapeutic options available for the management of PD motor complications include deep brain stimulation (DBS), ablative or lesioning procedures (pallidotomy, thalamotomy, subthalamotomy), and dopaminergic medication infusion devices. The decision to pursue these advanced treatment options is typically done by a multidisciplinary team by considering factors such as the patient's clinical characteristics, efficacy, ease of use, and risks of therapy with a goal to improve PD symptoms and quality of life. DBS has become the most widely used surgical therapy, although there is a re-emergence of interest in ablative procedures with the introduction of MR-guided focused ultrasound. In this article, we review DBS and lesioning procedures for PD, including indications, selection process, and management strategies.
Collapse
Affiliation(s)
- Vibhash D Sharma
- Department of Neurology, University of Kansas Medical Center, 3599 Rainbow Blvd, MS 3042, Kansas City, KS, 66160, USA.
| | - Margi Patel
- Department of Neurology, Emory University, Atlanta, GA, USA
| | | |
Collapse
|
10
|
Park HR, Lim YH, Song EJ, Lee JM, Park K, Park KH, Lee WW, Kim HJ, Jeon B, Paek SH. Bilateral Subthalamic Nucleus Deep Brain Stimulation under General Anesthesia: Literature Review and Single Center Experience. J Clin Med 2020; 9:jcm9093044. [PMID: 32967337 PMCID: PMC7564882 DOI: 10.3390/jcm9093044] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2020] [Revised: 09/13/2020] [Accepted: 09/17/2020] [Indexed: 02/07/2023] Open
Abstract
Bilateral subthalamic nucleus (STN) Deep brain stimulation (DBS) is a well-established treatment in patients with Parkinson's disease (PD). Traditionally, STN DBS for PD is performed by using microelectrode recording (MER) and/or intraoperative macrostimulation under local anesthesia (LA). However, many patients cannot tolerate the long operation time under LA without medication. In addition, it cannot be even be performed on PD patients with poor physical and neurological condition. Recently, it has been reported that STN DBS under general anesthesia (GA) can be successfully performed due to the feasible MER under GA, as well as the technical advancement in direct targeting and intraoperative imaging. The authors reviewed the previously published literature on STN DBS under GA using intraoperative imaging and MER, focused on discussing the technique, clinical outcome, and the complication, as well as introducing our single-center experience. Based on the reports of previously published studies and ours, GA did not interfere with the MER signal from STN. STN DBS under GA without intraoperative stimulation shows similar or better clinical outcome without any additional complication compared to STN DBS under LA. Long-term follow-up with a large number of the patients would be necessary to validate the safety and efficacy of STN DBS under GA.
Collapse
Affiliation(s)
- Hye Ran Park
- Department of Neurosurgery, Soonchunhyang University Seoul Hospital, Seoul 04401, Korea;
| | - Yong Hoon Lim
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
| | - Eun Jin Song
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
| | - Jae Meen Lee
- Department of Neurosurgery, Pusan National University Hospital, Busan 49241, Korea;
| | - Kawngwoo Park
- Department of Neurosurgery, Gachon University Gil Medical Center, Incheon 21565, Korea;
| | - Kwang Hyon Park
- Department of Neurosurgery, Chuungnam National University Sejong Hospital, Sejong 30099, Korea;
| | - Woong-Woo Lee
- Department of Neurology, Nowon Eulji Medical Center, Eulji University, Seoul 01830, Korea;
| | - Han-Joon Kim
- Department of Neurology, Seoul National University Hospital, Seoul 03080, Korea; (H.-J.K.); (B.J.)
| | - Beomseok Jeon
- Department of Neurology, Seoul National University Hospital, Seoul 03080, Korea; (H.-J.K.); (B.J.)
| | - Sun Ha Paek
- Department of Neurosurgery, Seoul National University Hospital, Seoul 03080, Korea; (Y.H.L.); (E.J.S.)
- Correspondence: ; Tel.: +82-22-072-2876
| |
Collapse
|
11
|
Holewijn RA, Bot M, van den Munckhof P, Schuurman PR. Implementation of Intraoperative Cone-Beam Computed Tomography (O-arm) for Stereotactic Imaging During Deep Brain Stimulation Procedures. Oper Neurosurg (Hagerstown) 2020; 19:E224-E229. [PMID: 32392290 PMCID: PMC7530565 DOI: 10.1093/ons/opaa110] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Accepted: 03/05/2020] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Intraoperative cone-beam computed tomography (iCBCT) allows for rapid 3-dimensional imaging. However, it is currently unknown whether this imaging technique offers sufficient accuracy for stereotactic registration during deep brain stimulation (DBS) procedures. OBJECTIVE To determine the accuracy of iCBCT, with the O-arm O2 (Medtronic), for stereotactic registration by comparing this modality to stereotactic magnetic resonance imaging (MRI). METHODS All DBS patients underwent a preoperative non-stereotactic 3 Tesla MRI, stereotactic 1.5 Tesla MRI, stereotactic O-arm iCBCT, postimplantation O-arm iCBCT, and postoperative conventional multidetector computed tomography (CT) scan. We compared stereotactic (X, Y, and Z) coordinates of the anterior commissure (AC), the posterior commissure (PC), and midline reference (MR) between stereotactic MRI and iCBCT. For localisation comparison of electrode contacts, stereotactic coordinates of electrode tips were compared between the postoperative multidetector CT and iCBCT. RESULTS A total of 20 patients were evaluated. The average absolute difference in stereotactic coordinates of AC, PC, and MR was 0.4 ± 0.4 mm for X, 0.4 ± 0.4 mm for Y, and 0.7 ± 0.5 mm for Z. The average absolute difference in X-, Y-, and Z-coordinates for electrode localisation (N = 34) was 0.3 ± 0.3 mm, 0.6 ± 0.3 mm, and 0.6 ± 0.6 mm. These differences were small enough not to be considered clinically relevant. CONCLUSION Stereotactic MRI and O-arm iCBCT yield comparable coordinates in pre- and postoperative imaging. Differences found are below the threshold of clinical relevance. Intraoperative O-arm CBCT offers rapid stereotactic registration and evaluation of electrode placement. This increases patient comfort and neurosurgical workflow efficiency.
Collapse
Affiliation(s)
- Rozemarije A Holewijn
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center (AMC), Amsterdam, The Netherlands
| | - Maarten Bot
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center (AMC), Amsterdam, The Netherlands
| | - Pepijn van den Munckhof
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center (AMC), Amsterdam, The Netherlands
| | - P Richard Schuurman
- Department of Neurosurgery, Amsterdam University Medical Centers, Academic Medical Center (AMC), Amsterdam, The Netherlands
| |
Collapse
|
12
|
Piano C, Bove F, Mulas D, Bentivoglio AR, Cioni B, Tufo T. Frameless stereotaxy in subthalamic deep brain stimulation: 3-year clinical outcome. Neurol Sci 2020; 42:259-266. [PMID: 32638134 PMCID: PMC7819924 DOI: 10.1007/s10072-020-04561-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 07/02/2020] [Indexed: 11/24/2022]
Abstract
Background In most centers, the surgery of deep brain stimulation (DBS) is performed using a stereotactic frame. Compared with frame-based technique, frameless stereotaxy reduces the duration of surgical procedure and patient’s discomfort, with lead placing accuracy equivalent after the learning curve. Although several studies have investigated the targeting accuracy of this technique, only a few studies reported clinical outcomes, with data of short-term follow-up. Objective To assess clinical efficacy and safety of frameless bilateral subthalamic nucleus (STN) DBS in Parkinson’s disease (PD) patients at 1- and 3-year follow-up. Methods Consecutive PD patients who underwent bilateral STN-DBS with a manual adjustable frameless system were included in the study. The data were collected retrospectively. Results Eighteen PD patients underwent bilateral STN-DBS implant and were included in the study. All patients completed 1-year observation and ten of them completed 3-year observation. At 1-year follow-up, motor efficacy of STN stimulation in off-med condition was of 30.1% (P = 0.003) and at 3-year follow-up was of 36.3%, compared with off-stim condition at 3-year follow-up (P = 0.005). Dopaminergic drugs were significantly reduced by 31.2% 1 year after the intervention (P = 0.003) and 31.7% 3 years after the intervention (P = 0.04). No serious adverse events occurred during surgery. Conclusions Frameless stereotaxy is an effective and safe technique for DBS surgery at 1- and 3-year follow-up, with great advantages for patients’ discomfort during surgery.
Collapse
Affiliation(s)
- Carla Piano
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy
| | - Francesco Bove
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy.
| | - Delia Mulas
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy.,Institute of Neurology, Mater Olbia Hospital, Olbia, Italy
| | - Anna Rita Bentivoglio
- Institute of Neurology, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Largo A. Gemelli 8, 00168, Rome, Italy
| | - Beatrice Cioni
- Institute of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Tommaso Tufo
- Institute of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
13
|
Zhang X, Uneri A, Webster Stayman J, Zygourakis CC, Lo SL, Theodore N, Siewerdsen JH. Known-component 3D image reconstruction for improved intraoperative imaging in spine surgery: A clinical pilot study. Med Phys 2019; 46:3483-3495. [PMID: 31180586 PMCID: PMC6692215 DOI: 10.1002/mp.13652] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 05/21/2019] [Accepted: 05/31/2019] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Intraoperative imaging plays an increased role in support of surgical guidance and quality assurance for interventional approaches. However, image quality sufficient to detect complications and provide quantitative assessment of the surgical product is often confounded by image noise and artifacts. In this work, we translated a three-dimensional model-based image reconstruction (referred to as "Known-Component Reconstruction," KC-Recon) for the first time to clinical studies with the aim of resolving both limitations. METHODS KC-Recon builds upon a penalized weighted least-squares (PWLS) method by incorporating models of surgical instrumentation ("known components") within a joint image registration-reconstruction process to improve image quality. Under IRB approval, a clinical pilot study was conducted with 17 spine surgery patients imaged under informed consent using the O-arm cone-beam CT system (Medtronic, Littleton MA) before and after spinal instrumentation. Volumetric images were generated for each patient using KC-Recon in comparison to conventional filtered backprojection (FBP). Imaging performance prior to instrumentation ("preinstrumentation") was evaluated in terms of soft-tissue contrast-to-noise ratio (CNR) and spatial resolution. The quality of images obtained after the instrumentation ("postinstrumentation") was assessed by quantifying the magnitude of metal artifacts (blooming and streaks) arising from pedicle screws. The potential low-dose advantages of the algorithm were tested by simulating low-dose data (down to one-tenth of the dose of standard protocols) from images acquired at normal dose. RESULTS Preinstrumentation images (at normal clinical dose and matched resolution) exhibited an average 24.0% increase in soft-tissue CNR with KC-Recon compared to FBP (N = 16, P = 0.02), improving visualization of paraspinal muscles, major vessels, and other soft-tissues about the spine and abdomen. For a total of 72 screws in postinstrumentation images, KC-Recon yielded a significant reduction in metal artifacts: 66.3% reduction in overestimation of screw shaft width due to blooming (P < 0.0001) and reduction in streaks at the screw tip (65.8% increase in attenuation accuracy, P < 0.0001), enabling clearer depiction of the screw within the pedicle and vertebral body for an assessment of breach. Depending on the imaging task, dose reduction up to an order of magnitude appeared feasible while maintaining soft-tissue visibility and metal artifact reduction. CONCLUSIONS KC-Recon offers a promising means to improve visualization in the presence of surgical instrumentation and reduce patient dose in image-guided procedures. The improved soft-tissue visibility could facilitate the use of cone-beam CT to soft-tissue surgeries, and the ability to precisely quantify and visualize instrument placement could provide a valuable check against complications in the operating room (cf., postoperative CT).
Collapse
Affiliation(s)
- Xiaoxuan Zhang
- Department of Biomedical EngineeringJohns Hopkins UniversityBaltimoreMD21205USA
| | - Ali Uneri
- Department of Biomedical EngineeringJohns Hopkins UniversityBaltimoreMD21205USA
| | - J. Webster Stayman
- Department of Biomedical EngineeringJohns Hopkins UniversityBaltimoreMD21205USA
| | | | - Sheng‐fu L. Lo
- Department of NeurosurgeryJohns Hopkins Medical InstituteBaltimoreMD21287USA
| | - Nicholas Theodore
- Department of NeurosurgeryJohns Hopkins Medical InstituteBaltimoreMD21287USA
| | - Jeffrey H. Siewerdsen
- Department of Biomedical EngineeringJohns Hopkins UniversityBaltimoreMD21205USA
- Department of NeurosurgeryJohns Hopkins Medical InstituteBaltimoreMD21287USA
| |
Collapse
|
14
|
Bus S, Pal G, Ouyang B, van den Munckhof P, Bot M, Sani S, Verhagen Metman L. Accuracy of Microelectrode Trajectory Adjustments during DBS Assessed by Intraoperative CT. Stereotact Funct Neurosurg 2018; 96:231-238. [PMID: 30145596 DOI: 10.1159/000489945] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Accepted: 05/09/2018] [Indexed: 11/19/2022]
Abstract
BACKGROUND/AIMS Microelectrode recording (MER)-guided deep brain stimulation (DBS) aims to place the DBS lead in the optimal electrophysiological target. When single-track MER or test stimulation yields suboptimal results, trajectory adjustments are made. The accuracy of these trajectory adjustments is unknown. Intraoperative computed tomography can visualize the microelectrode (ME) and verify ME adjustments. We aimed to determine the accuracy of ME movements in patients undergoing MER-guided DBS. METHODS Coordinates following three methods of adjustment were compared: (1) those within the default "+" configuration of the ME holder; (2) those involving rotation of the default "+" to the "x" configuration; and (3) those involving head stage adjustments. Radial error and absolute differences between coordinates were determined. RESULTS 87 ME movements in 59 patients were analyzed. Median (IQR) radial error was 0.59 (0.64) mm. Median (IQR) absolute x and y coordinate errors were 0.29 (0.52) and 0.38 (0.44) mm, respectively. Errors were largest after rotating the multielectrode holder to its "x"-shaped setup. CONCLUSION ME trajectory adjustments can be made accurately. In a considerable number of cases, errors exceeding 1 mm were found. Adjustments from the "+" setup to the "x" setup are most prone to inaccuracies.
Collapse
Affiliation(s)
- Sander Bus
- Department of Neurology, Amsterdam UMC, Amsterdam, the Netherlands
| | - Gian Pal
- Department of Neurological Sciences, Rush University Medical Center, Chicago, Illinois, USA
| | - Bichun Ouyang
- Department of Neurological Sciences, Rush University Medical Center, Chicago, Illinois, USA
| | | | - Maarten Bot
- Department of Neurosurgery, Amsterdam UMC, Amsterdam, the Netherlands
| | - Sepehr Sani
- Department of Neurosurgery, Rush University Medical Center, Chicago, Illinois, USA
| | - Leo Verhagen Metman
- Department of Neurological Sciences, Rush University Medical Center, Chicago, Illinois, USA
| |
Collapse
|
15
|
Bus S, van den Munckhof P, Bot M, Pal G, Ouyang B, Sani S, Verhagen Metman L. Borders of STN determined by MRI versus the electrophysiological STN. A comparison using intraoperative CT. Acta Neurochir (Wien) 2018; 160:373-383. [PMID: 29275518 PMCID: PMC5766705 DOI: 10.1007/s00701-017-3432-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 12/06/2017] [Indexed: 12/25/2022]
Abstract
Background It is unclear which magnetic resonance imaging (MRI) sequence most accurately corresponds with the electrophysiological subthalamic nucleus (STN) obtained during microelectrode recording (MER, MER-STN). CT/MRI fusion allows for comparison between MER-STN and the STN visualized on preoperative MRI (MRI-STN). Objective To compare dorsal and ventral STN borders as seen on 3-Tesla T2-weighted (T2) and susceptibility weighted images (SWI) with electrophysiological STN borders in deep brain stimulation (DBS) for Parkinson’s disease (PD). Methods Intraoperative CT (iCT) was performed after each MER track. iCT images were merged with preoperative images using planning software. Dorsal and ventral borders of each track were determined and compared to MRI-STN borders. Differences between borders were calculated. Results A total of 125 tracks were evaluated in 45 patients. MER-STN started and ended more dorsally than respective dorsal and ventral MRI-STN borders. For dorsal borders, differences were 1.9 ± 1.4 mm (T2) and 2.5 ± 1.8 mm (SWI). For ventral borders, differences were 1.9 ± 1.6 mm (T2) and 2.1 ± 1.8 mm (SWI). Conclusions Discrepancies were found comparing borders on T2 and SWI to the electrophysiological STN. The largest border differences were found using SWI. Border differences were considerably larger than errors associated with iCT and fusion techniques. A cautious approach should be taken when relying solely on MR imaging for delineation of both clinically relevant STN borders.
Collapse
|
16
|
Awake versus Asleep Deep Brain Stimulation Surgery: Technical Considerations and Critical Review of the Literature. Brain Sci 2018; 8:brainsci8010017. [PMID: 29351243 PMCID: PMC5789348 DOI: 10.3390/brainsci8010017] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 01/08/2018] [Accepted: 01/16/2018] [Indexed: 11/22/2022] Open
Abstract
Advancements in neuroimaging have led to a trend toward direct, image-based targeting under general anesthesia without the use of microelectrode recording (MER) or intraoperative test stimulation, also referred to as “asleep” deep brain stimulation (DBS) surgery. Asleep DBS, utilizing imaging in the form of intraoperative computed tomography (iCT) or magnetic resonance imaging (iMRI), has demonstrated reliable targeting accuracy of DBS leads implanted within the globus pallidus and subthalamic nucleus while also improving clinical outcomes in patients with Parkinson’s disease. In lieu, of randomized control trials, retrospective comparisons between asleep and awake DBS with MER have shown similar short-term efficacy with the potential for decreased complications in asleep cohorts. In lieu of long-term outcome data, awake DBS using MER must demonstrate more durable outcomes with fewer stimulation-induced side effects and lead revisions in order for its use to remain justifiable; although patient-specific factors may also be used to guide the decision regarding which technique may be most appropriate and tolerable to the patient.
Collapse
|
17
|
Li Z, Zhang JG, Ye Y, Li X. Review on Factors Affecting Targeting Accuracy of Deep Brain Stimulation Electrode Implantation between 2001 and 2015. Stereotact Funct Neurosurg 2016; 94:351-362. [PMID: 27784015 DOI: 10.1159/000449206] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Accepted: 08/16/2016] [Indexed: 11/19/2022]
Abstract
BACKGROUND Accurate implantation of a depth electrode into the brain is of the greatest importance in deep brain stimulation (DBS), and various stereotactic systems have been developed for electrode implantation. However, an updated analysis of depth electrode implantation in the modern era of DBS is lacking. OBJECTIVE This study aims at providing an updated review on targeting accuracy of DBS electrode implantation by analyzing contemporary DBS electrode implantation operations from the perspective of precision engineering. METHODS Eligible articles with information on targeting accuracy of DBS electrode implantation were searched in the PubMed database. RESULTS An average targeting error of DBS electrode implantation is reported to decrease toward 1 mm; the standard deviation of targeting error is decreasing toward 0.5 mm. Targeting accuracy is not only found to be affected by individual surgical steps, but also systematically affected by the architecture of the implantation operation. CONCLUSION A systematic strategy should be adopted to further improve the targeting accuracy of depth electrode implantation. Attention should be paid to optimizing the whole electrode implantation operation, which can help minimize error accumulation or amplification throughout the serially connected procedures for DBS electrode implantation.
Collapse
Affiliation(s)
- Zhe Li
- Department of Biomedical Engineering, National University of Singapore, Singapore, Singapore
| | | | | | | |
Collapse
|
18
|
Servello D, Zekaj E, Saleh C, Pacchetti C, Porta M. The pros and cons of intraoperative CT scan in evaluation of deep brain stimulation lead implantation: A retrospective study. Surg Neurol Int 2016; 7:S551-6. [PMID: 27583182 PMCID: PMC4982342 DOI: 10.4103/2152-7806.187534] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Accepted: 04/27/2016] [Indexed: 11/04/2022] Open
Abstract
BACKGROUND Deep brain stimulation (DBS) is an established therapy for movement disorders, such as Parkinson's disease (PD), dystonia, and tremor. The efficacy of DBS depends on the correct lead positioning. The commonly adopted postoperative radiological evaluation is performed with computed tomography (CT) scan and/or magnetic resonance imaging (MRI). METHODS We conducted a retrospective study on 202 patients who underwent DBS from January 2009 to October 2013. DBS indications were PD, progressive supranuclear palsy, tremor, dystonia, Tourette syndrome, obsessive compulsive disorder, depression, and Huntington's disease. Preoperatively, all patients underwent brain MRI and brain CT scan with the stereotactic frame positioned. The lead location was confirmed intraoperatively with CT. The CT images were subsequently transferred to the Stealth Station Medtronic and merged with the preoperative planning. On the first or second day after, implantation we performed a brain MRI to confirm the correct position of the lead. RESULTS In 14 patients, leads were in suboptimal position after intraoperative CT scan positioning. The cases with alteration in the Z-axis were corrected immediately under fluoroscopic guidance. In all the 14 patients, an immediate repositioning was done. CONCLUSIONS Based on our data, intraoperative CT scan is fast, safe, and a useful tool in the evaluation of the position of the implanted lead. It also reduces the patient's discomfort derived from the transfer of the patient from the operating room to the radiological department. However, intraoperative CT should not be considered as a substitute for postoperative MRI.
Collapse
Affiliation(s)
- Domenico Servello
- Department of Neurology and Neurosurgery, IRCCS Galeazzi, Milan, Italy
| | - Edvin Zekaj
- Department of Neurology and Neurosurgery, IRCCS Galeazzi, Milan, Italy
| | - Christian Saleh
- Department of Neurology and Neurosurgery, IRCCS Galeazzi, Milan, Italy
| | - Claudio Pacchetti
- Department of Neurology and Neurosurgery, IRCCS Galeazzi, Milan, Italy
| | - Mauro Porta
- Department of Neurology and Neurosurgery, IRCCS Galeazzi, Milan, Italy
| |
Collapse
|
19
|
Ughratdar I, Samuel M, Ashkan K. Technological Advances in Deep Brain Stimulation. JOURNAL OF PARKINSONS DISEASE 2016; 5:483-96. [PMID: 26406128 DOI: 10.3233/jpd-150579] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Functional and stereotactic neurosurgery has always been regarded as a subspecialty based on and driven by technological advances. However until recently, the fundamentals of deep brain stimulation (DBS) hardware and software design had largely remained stagnant since its inception almost three decades ago. Recent improved understanding of disease processes in movement disorders as well clinician and patient demands has resulted in new avenues of development for DBS technology. This review describes new advances both related to hardware and software for neuromodulation. New electrode designs with segmented contacts now enable sophisticated shaping and sculpting of the field of stimulation, potentially allowing multi-target stimulation and avoidance of side effects. To avoid lengthy programming sessions utilising multiple lead contacts, new user-friendly software allows for computational modelling and individualised directed programming. Therapy delivery is being improved with the next generation of smaller profile, longer-lasting, re-chargeable implantable pulse generators (IPGs). These include IPGs capable of delivering constant current stimulation or personalised closed-loop adaptive stimulation. Post-implantation Magnetic Resonance Imaging (MRI) has long been an issue which has been partially overcome with 'MRI conditional devices' and has enabled verification of DBS lead location. Surgical technique is considering a shift from frame-based to frameless stereotaxy or greater role for robot assisted implantation. The challenge for these contemporary techniques however, will be in demonstrating equivalent safety and accuracy to conventional methods. We also discuss potential future direction utilising wireless technology allowing for miniaturisation of hardware.
Collapse
|
20
|
Sharma M, Deogaonkar M. Accuracy and safety of targeting using intraoperative “O-arm” during placement of deep brain stimulation electrodes without electrophysiological recordings. J Clin Neurosci 2016; 27:80-6. [DOI: 10.1016/j.jocn.2015.06.036] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2015] [Revised: 06/16/2015] [Accepted: 06/20/2015] [Indexed: 10/22/2022]
|
21
|
Hickey P, Stacy M. Deep Brain Stimulation: A Paradigm Shifting Approach to Treat Parkinson's Disease. Front Neurosci 2016; 10:173. [PMID: 27199637 PMCID: PMC4848307 DOI: 10.3389/fnins.2016.00173] [Citation(s) in RCA: 64] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2016] [Accepted: 04/04/2016] [Indexed: 11/13/2022] Open
Abstract
Parkinson disease (PD) is a chronic and progressive movement disorder classically characterized by slowed voluntary movements, resting tremor, muscle rigidity, and impaired gait and balance. Medical treatment is highly successful early on, though the majority of people experience significant complications in later stages. In advanced PD, when medications no longer adequately control motor symptoms, deep brain stimulation (DBS) offers a powerful therapeutic alternative. DBS involves the surgical implantation of one or more electrodes into specific areas of the brain, which modulate or disrupt abnormal patterns of neural signaling within the targeted region. Outcomes are often dramatic following DBS, with improvements in motor function and reductions motor complications having been repeatedly demonstrated. Given such robust responses, emerging indications for DBS are being investigated. In parallel with expansions of therapeutic scope, advancements within the areas of neurosurgical technique and the precision of stimulation delivery have recently broadened as well. This review focuses on the revolutionary addition of DBS to the therapeutic armamentarium for PD, and summarizes the technological advancements in the areas of neuroimaging and biomedical engineering intended to improve targeting, programming, and overall management.
Collapse
Affiliation(s)
- Patrick Hickey
- Department of Neurology, Duke University Medical CenterDurham, NC, USA
| | | |
Collapse
|
22
|
Mirzadeh Z, Chapple K, Lambert M, Dhall R, Ponce FA. Validation of CT-MRI fusion for intraoperative assessment of stereotactic accuracy in DBS surgery. Mov Disord 2014; 29:1788-95. [DOI: 10.1002/mds.26056] [Citation(s) in RCA: 97] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Revised: 07/09/2014] [Accepted: 09/19/2014] [Indexed: 12/21/2022] Open
Affiliation(s)
- Zaman Mirzadeh
- Division of Neurological Surgery, Barrow Neurological Institute; St. Joseph's Hospital and Medical Center; Phoenix Arizona
| | - Kristina Chapple
- Division of Neurological Surgery, Barrow Neurological Institute; St. Joseph's Hospital and Medical Center; Phoenix Arizona
| | - Meg Lambert
- Division of Neurological Surgery, Barrow Neurological Institute; St. Joseph's Hospital and Medical Center; Phoenix Arizona
| | - Rohit Dhall
- Division of Neurological Surgery, Barrow Neurological Institute; St. Joseph's Hospital and Medical Center; Phoenix Arizona
| | - Francisco A. Ponce
- Division of Neurological Surgery, Barrow Neurological Institute; St. Joseph's Hospital and Medical Center; Phoenix Arizona
| |
Collapse
|
23
|
Ohtaka K, Takahashi Y, Kaga K, Senmaru N, Kotani Y, Matsui Y. Video-assisted thoracoscopic surgery using mobile computed tomography: new method for locating of small lung nodules. J Cardiothorac Surg 2014; 9:110. [PMID: 24947848 PMCID: PMC4075622 DOI: 10.1186/1749-8090-9-110] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Accepted: 06/12/2014] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The O-arm is an intraoperative imaging device that can provide computed tomography images. Surgery for small lung tumors was performed based on intraoperative computed tomography images obtained using the O-arm. This study evaluated the usefulness of the O-arm in thoracic surgery. METHODS From July 2013 to November 2013, 10 patients with small lung nodules or ground glass nodules underwent video-assisted thoracoscopic surgery using the O-arm. A needle was placed on the visceral pleura near the nodules. After the lung was re-expanded, intraoperative computed tomography was performed using the O-arm. Then, the positional relationship between the needle marking and the tumor was recognized based on the intraoperative computed tomography images, and lung resection was performed. RESULTS In 9 patients, the tumor could be seen on intraoperative computed tomography images using the O-arm. In 1 patient with a ground glass nodule, the lesion could not be seen, but its location could be inferred by comparison between preoperative and intraoperative computed tomography images. In only 1 patient with a ground glass nodule, a pathological complete resection was not performed. There were no complications related to the use of the O-arm. CONCLUSIONS The O-arm may be an additional tool to facilitate intraoperative localization and surgical resection of non-palpable lung lesions.
Collapse
Affiliation(s)
- Kazuto Ohtaka
- Department of Thoracic Surgery, Steel Memorial Muroran Hospital, Chiribetsu-cho, 050-0076 Muroran, Hokkaido, Japan.
| | | | | | | | | | | |
Collapse
|
24
|
|
25
|
Abstract
Technological innovations have driven the advancement of the surgical treatment of movement disorders, from the invention of the stereotactic frame to the adaptation of deep brain stimulation (DBS). Along these lines, this review will describe recent advances in inserting neuromodulation modalities, including DBS, to the target, and in the delivery of therapy at the target. Recent radiological advances are altering the way that DBS leads are targeted and inserted, by refining the ability to visualize the subcortical targets using high-field strength magnetic resonance imaging and other innovations, such as diffusion tensor imaging, and the development of novel targeting devices enabling purely anatomical implantations without the need for neurophysiological monitoring. New portable computed tomography scanners also are facilitating lead implantation without monitoring, as well as improving radiological verification of DBS lead location. Advances in neurophysiological mapping include efforts to develop automatic target verification algorithms, and probabilistic maps to guide target selection. The delivery of therapy at the target is being improved by the development of the next generation of internal pulse generators (IPGs). These include constant current devices that mitigate the variability introduced by impedance changes of the stimulated tissue and, in the near future, devices that deliver novel stimulation patterns with improved efficiency. Closed-loop adaptive IPGs are being tested, which may tailor stimulation to ongoing changes in the nervous system, reflected in biomarkers continuously recorded by the devices. Finer-grained DBS leads, in conjunction with new IPGs and advanced programming tools, may offer improved outcomes via current steering algorithms. Finally, even thermocoagulation-essentially replaced by DBS-is being advanced by new minimally-invasive approaches that may improve this therapy for selected patients in whom it may be preferred. Functional neurosurgery has a history of being driven by technological innovation, a tradition that continues into its future.
Collapse
Affiliation(s)
- Robert E Gross
- Department of Neurosurgery, Emory University School of Medicine, 1365 Clifton Road, NE Suite 6200, Atlanta, GA 30322, USA.
| | | |
Collapse
|