Gonzalez AI, Barea C, Zingg M, Garavaglia G, Peter R, Hoffmeyer P, Hannouche D, Lübbeke A. Long-term outcomes of small head metal-on-metal compared to ceramic-on-polyethylene primary total hip arthroplasty: a registry-based cohort study. INTERNATIONAL ORTHOPAEDICS 2025; 49:605-612. [PMID: 39937240 PMCID: PMC11889049 DOI: 10.1007/s00264-025-06437-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2024] [Accepted: 01/31/2025] [Indexed: 02/13/2025]
Abstract
PURPOSE We aimed to compare the long-term outcomes of small-head (28 mm) metal-on-metal (MoM) total hip arthroplasty (THA) to ceramic-on-polyethylene (CoP) THA using the same cup. METHODS All primary elective MoM and CoP THAs performed 1998-2011 were prospectively included in a local registry. Patients were followed until 31 December 2022. Outcomes were all-cause revision, complications and mortality. The uncemented Morscher 28 mm monobloc press-fit cup was used in all THAs. RESULTS Overall, 3257 THAs were included, 864 MoM (mean age 63) and 2393 CoP THAs (mean age 72). Mean follow-up of the cohort was 12.9 years (maximum 26.8 years). Revision for any cause was performed in 85 MoM and 79 CoP THAs. Cumulative incidence of all-cause revision at 20 years was 13.2% (95% CI 10.6 to 16.3) in MoM and 6.3% (95% CI 4.8 to 8.3) in CoP group. Adjusted hazard ratio for all-cause revision was 1.88 (95% CI 1.34 to 2.65) comparing MoM vs. CoP. Diagnoses at revision were mainly aseptic loosening (33%) and adverse local tissue reactions (33%) in MoM and aseptic loosening in CoP group (44%). The smoothed hazard function revealed the largest difference in instantaneous revision rate between three and 14 years postoperative. After that period no difference was observed. CONCLUSION Overall, the cumulative risk of all-cause revision was almost twice as high in patients with a small head MoM as compared to a CoP THA over the 20-year period. However, most of the excess in revisions among MoM patients occurred between three and 14 years postoperative.
Collapse
Affiliation(s)
- Amanda I Gonzalez
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland.
| | - Christophe Barea
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Matthieu Zingg
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Guido Garavaglia
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Robin Peter
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Pierre Hoffmeyer
- SWISS Foundation for Innovation and Training in Surgery, Geneva, Switzerland
| | - Didier Hannouche
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Anne Lübbeke
- Division of Orthopaedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland
- Nuffield Department of Orthopaedics, Rheumatology and Musculoskeletal Sciences, University of Oxford, Oxford, UK
| |
Collapse
|
2
|
Gaillard-Campbell D, Gross T. Magnum metal-on-metal uncemented total hip replacement: 8- to 18-year outcomes of 211 cases. Musculoskelet Surg 2024; 108:449-457. [PMID: 38833069 PMCID: PMC11582121 DOI: 10.1007/s12306-024-00831-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Accepted: 05/17/2024] [Indexed: 06/06/2024]
Abstract
BACKGROUND Reports of adverse reactions to metal debris contributed in part to a decline in use of large-bearing metal-on-metal total hip devices. We hypothesize an optimal trunnion design may reduce risk of this failure mode in large-bearing total hip arthroplasty systems. The purpose of this study is to report mid- to long-term outcomes for a single-surgeon series of 211 total hip arthroplasties using the large-bearing Biomet Magnum metal-on-metal system. MATERIALS AND METHODS Between December 2004 and January 2016, the primary surgeon performed 211 uncemented Magnum total hip arthroplasties in 181 patients. The average length of follow-up was 10.1 ± 3.5 years (range 8-18 years). RESULTS Using failure of any component as the endpoint, the overall survivorship rate was 98.1% at 10 years and 97.4% at 18 years. These eight failures (3.8% of cohort) included one case of adverse wear-related failure (0.5%), two cases of acetabular ingrowth failure (0.9%), three cases of trunnion corrosion (1.4%), one failure of late infection (0.5%), and one inappropriate revision of components for trochanteric nonunion without instability (0.5%). Excluding failed cases, all components were radiographically stable with no radiolucencies. Except for the one wear failure, ion testing revealed that 97.2% of cases were within optimal whole blood metal ion levels with the remaining ion test results within acceptable levels. CONCLUSIONS With the uncemented Magnum metal-on-metal total hip, we achieved 97.4% 18-year implant survivorship, exceeding the NICE criteria and registry benchmarks for implant survivorship. We observed a trunnion corrosion rate of 1.4% and no cases of instability. The single case of adverse wear-related failure was caused by acetabular component malposition.
Collapse
Affiliation(s)
- D Gaillard-Campbell
- Midlands Orthopaedics and Neurosurgery, PA, 1910 Blanding Street, Columbia, SC, 29201, USA.
| | - T Gross
- Midlands Orthopaedics and Neurosurgery, PA, 1910 Blanding Street, Columbia, SC, 29201, USA
| |
Collapse
|
3
|
Sathishkumar S, Paulraj J, Chakraborti P, Muthuraj M. Comprehensive Review on Biomaterials and Their Inherent Behaviors for Hip Repair Applications. ACS APPLIED BIO MATERIALS 2023; 6:4439-4464. [PMID: 37871169 DOI: 10.1021/acsabm.3c00327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2023]
Abstract
Developing biomaterials for hip prostheses is challenging and requires dedicated attention from researchers. Hip replacement is an inevitable and remarkable orthopedic therapy for enhancing the quality of patient life for those who have arthritis as well as trauma. Generally, five types of hip replacement procedures are successfully performed in the current medical market: total hip replacements, hip resurfacing, hemiarthroplasty, bipolar, and dual mobility systems. The average life span of artificial hip joints is about 15 years, and several studies have been conducted over the last 60 years to improve the performance and thereby increase the lifespan of artificial hip joints. Present-day prosthetic hip joints are linked to the wide availability of biomaterials. Metals, ceramics, and polymers are some of the most promising types of biomaterials; nevertheless, each biomaterial has advantages and disadvantages. Metals and ceramics fail in most applications owing to stress shielding and the emission of wear debris; ongoing research is being carried out to find a remedy to these unfavorable responses. Recent research found that polymers and composites based on polymers are significant alternative materials for artificial joints. With growing research and several biomaterials, recent reviews lag in effectively addressing hip implant materials' individual mechanical, tribological, and physiological behaviors. This Review comprehensively investigates the historical evolution of artificial hip replacement procedures and related biomaterials' mechanical, tribological, and biological characteristics. In addition, the most recent advances are also discussed to stimulate and guide future researchers as they seek more effective methods and synthesis of innovative biomaterials for hip arthroplasty application.
Collapse
|
4
|
Hunger S, Seidler A, Rotsch C, Heyde CE, Drossel WG. Evaluating the Feasibility and Reproducibility of a Novel Insertion Method for Modular Acetabular Ceramic Liners. Bioengineering (Basel) 2023; 10:1180. [PMID: 37892910 PMCID: PMC10604853 DOI: 10.3390/bioengineering10101180] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2023] [Revised: 09/24/2023] [Accepted: 10/03/2023] [Indexed: 10/29/2023] Open
Abstract
Modern hip implants have a modular design. In case of wear or other damage it allows surgeons to change the tribological partners, i.e., the acetabular liner and femoral ball. In both revision and primary surgery, the secure joining of the implant components is important for the success of the operation. The two components, namely the ceramic liner and hip cup, are connected via a conical press connection and should be concentrically aligned to avoid chipping. Malseated liners can reduce the life span in situ. The amount of the joining force, which is usually applied via a hammer, depends on the surgeon. In this study, an alternative joining method for acetabular ceramic liners in hip cups was investigated, which intends to make the process more reproducible and thus safer. For this purpose, a handpiece was used to apply a defined force impulse of 4 kN. For the concentric alignment of a ceramic liner in the hip cup, an adapter was developed based on findings via a qualitative finite element (FE) analysis. Insertion and pushout tests of the acetabular cup-liner connection were performed in the laboratory with the new instrument (handpiece with the connected adapter) to evaluate the functionality of the instrument and the reproducibility of the new insertion method. For comparison, liners and acetabular cups were joined using a testing machine according to the standard. The presented results demonstrate the technical proof-of-concept of the new joining method under laboratory conditions. They meet the acceptance criteria of established manufacturers, which proves the equivalency to proven methods for joining modular implant components. To verify the improvement of the new joining method compared to the conventionally used joining method, an application-oriented study with different surgeons and the new joining instrument under clinical conditions is necessary.
Collapse
Affiliation(s)
- Sandra Hunger
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany;
| | - Alexander Seidler
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Institute of Machine Elements and Machine Design, Faculty of Mechanical Science and Engineering, Dresden University of Technology, 01062 Dresden, Germany
| | - Christian Rotsch
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany;
| | - Christoph-Eckhard Heyde
- Department of Orthopaedic, Trauma and Plastic Surgery Clinic, University of Leipzig Medical Center, 04103 Leipzig, Germany;
| | - Welf-Guntram Drossel
- Fraunhofer Institute for Machine Tools and Forming Technology IWU, 01187 Dresden, Germany; (A.S.); (C.R.); (W.-G.D.)
- Institute for Machine Tools and Production Processes, Faculty of Mechanical Engineering, Chemnitz University of Technology, 09111 Chemnitz, Germany
| |
Collapse
|
5
|
He B, Li X, Dong R, Tong P, Sun J. A multi-center retrospective comparative study of third generation Ceramic-on- Ceramic total hip arthroplasty in patients younger than 45 years with or without the sandwich liner: A ten-year minimum. J Orthop Surg (Hong Kong) 2022; 30:10225536221109960. [PMID: 35722861 DOI: 10.1177/10225536221109960] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. However, the material in THA still remains one of the major concerns about the risk of fracture, due to its brittleness. OBJECTIVE The present study aims at reporting the fracture rate of a series of ceramic-on-ceramic THAs with use of the sandwich liner combined with a ceramic femoral head, and attempt to detect the relative risk factors, possible cause and assesse the medium-term clinical results. METHODS We retrospectively evaluated 282 patients (300 hips) with use of the sandwich liner ceramic-on-ceramic THA between 2001 and 2009 at three-centers. Patient assessment was based on demographic factors, including age, weight, gender and body-mass index. All patients were evaluated clinically and radio-graphically or computed tomography in consideration of dislocation, osteolysis, periprosthetic fracture, infection, loosening and implant fracture. RESULTS five ceramic sandwich liners fracture (1.7%) were observed at an average of 7.3 years follow-up. These factors were irrelevant to the ceramic liner fracture, including age (p = 0.205), weight (p = 0.241), gender (p = 0.553), body-mass index (p = 0.736), inclination (p = 0.727), and anteversion (p = 0.606). The overall survival was 91.4% at 12 years with revision as the endpoint. Other complications included dislocation in two, perprosthetic fracture in two and osteolysis in eight hips. No hip had aseptic loosening of the implants was seen. CONCLUSIONS We found that the sandwich liner may be lead to a high rate of alumina fracture and osteolysis. We have discontinued the use of sandwich liner with THA since 2009.
Collapse
Affiliation(s)
- Bangjian He
- Department of Orthopedics, The First Affiliated Hospital of Zhejiang Traditional Chinese Medicine University, Hangzhou, China
| | - Xigong Li
- Department of Orthopedics, 71069The First Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, China
| | - Rui Dong
- Department of Orthopedics, The First Affiliated Hospital of Zhejiang Traditional Chinese Medicine University, Hangzhou, China
| | - Peijian Tong
- Department of Orthopedics, The First Affiliated Hospital of Zhejiang Traditional Chinese Medicine University, Hangzhou, China
| | - Junying Sun
- Department of Orthopedics, 74566The First Affiliated Hospital of Soochow University, Suzhou, China
| |
Collapse
|
6
|
Xu T, Zhang J. Effect of Operation Room Nursing Intervention and Ceramic Prosthesis on Total Hip Arthroplasty. SCANNING 2022; 2022:2421723. [PMID: 35832302 PMCID: PMC9239831 DOI: 10.1155/2022/2421723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/06/2022] [Accepted: 06/13/2022] [Indexed: 06/15/2023]
Abstract
In order to solve the problems of large trauma, many postoperative complications, and complex operation of artificial hip arthroplasty, a method to analyze the application effect of operating room nursing intervention in artificial hip arthroplasty was proposed. Firstly, 120 patients who underwent hip arthroplasty in our hospital from January to December 2017 were selected; Secondly, they were randomly divided into routine group (60 cases) and intervention group (60 cases); finally, on this basis, the intervention group strengthened the nursing in the operating room and used nanoceramic prosthesis. The Harris score of hip joint, the incidence of postoperative complications, and the satisfaction with nursing services were compared between the two groups. The results showed that the Harris score of hip joint and the satisfaction score of nursing service in the intervention group were significantly higher than those in the routine group (P < 0.05); the incidence of postoperative complications in the intervention group was significantly lower than that in the routine group (P < 0.05). It is proved that actively carrying out nursing intervention in the operating room and using nanoceramic prosthesis can not only improve the clinical efficacy and nursing service satisfaction of patients undergoing total hip arthroplasty but also reduce the incidence of complications.
Collapse
Affiliation(s)
- Ting Xu
- Marine Police Hospital of Anesthesiology Department, Jiaxing, Zhejiang 314000, China
| | - Jie Zhang
- Marine Police Hospital of Anesthesiology Department, Jiaxing, Zhejiang 314000, China
| |
Collapse
|
7
|
Farhan-Alanie OMH, Hrycaiczuk A, Tinning C, Jones B, Stark A, Bryceland K. Alumina ceramic-on-ceramic hybrid total hip arthroplasty. A median of 15 years follow-up. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2021; 32:1127-1136. [PMID: 34357474 DOI: 10.1007/s00590-021-03087-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Accepted: 07/29/2021] [Indexed: 10/20/2022]
Abstract
INTRODUCTION The optimum choice of bearing surfaces in total hip replacement (THR) in the younger and active patient remains controversial. The aim of this study was to report the 10 year clinical outcomes, and a median of 15 year implant survival and incidence of complications in a series of Alumina ceramic-on-ceramic THRs utilising an uncemented shell and cemented stem. METHODS From January 2004 to December 2007, 175 consecutive patients (195 hips) underwent primary THR. The acetabular components was Trident Peripheral Self Locking (Stryker Orthopaedics) with a third-generation ceramic head and liner (Alumina ceramic, Stryker Orthopaedics). The stem utilised was an Exeter V-40 (Stryker Orthopaedics). Data were collated on demographics, surgical factors, clinical outcomes, radiographic outcomes and revision. RESULTS 23 patients (27 THRs) died during the follow-up period at a median of 7.8 (3.8 to 9.0) years post-operatively due to causes unrelated to the THR. Median age at time of surgery was 55 (interquartile range 48-60) years. Median follow-up for surviving patients was 15.2 years. Survivorship for all-cause revision was 97.2%. Increasing patient age at time of surgery was associated with a higher OHS at 10 years (p = 0.022). 32 mm head diameter had an improved OHS at 3 months (p = 0.014) and 10 years (p = 0.030). Posterior surgical approach had a statistically significant better OHS at 3 months (p = 0.015) and 1 year (p < 0.001), but the effect was not significant at 10 years (p = 0.440). CONCLUSION The findings of this study support excellent long-term outcomes and survivorship of Alumina ceramic-on-ceramic bearing in a hybrid THR in a younger population. Surgical factors leading to a more favourable outcome were the use of a 32 mm femoral head and a posterior approach. Increasing age at surgery demonstrated the most sustained improvement in 10 year clinical outcomes.
Collapse
Affiliation(s)
- Omer M H Farhan-Alanie
- Department of Trauma and Orthopaedic Surgery, Glasgow Royal Infirmary, 84 Castle St, Glasgow, G4 0SF, UK.
| | - Alex Hrycaiczuk
- Department of Trauma and Orthopaedic Surgery, Glasgow Royal Infirmary, 84 Castle St, Glasgow, G4 0SF, UK
| | - Craig Tinning
- Department of Trauma and Orthopaedic Surgery, Forth Valley Royal Hospital, Stirling Rd, Larbert, FK5 4WR, UK
| | - Bryn Jones
- Department of Trauma and Orthopaedic Surgery, Glasgow Royal Infirmary, 84 Castle St, Glasgow, G4 0SF, UK
| | - Andrew Stark
- Department of Trauma and Orthopaedic Surgery, Glasgow Royal Infirmary, 84 Castle St, Glasgow, G4 0SF, UK
| | - Kevin Bryceland
- Department of Trauma and Orthopaedic Surgery, Glasgow Royal Infirmary, 84 Castle St, Glasgow, G4 0SF, UK
| |
Collapse
|
8
|
Austin MS, Ashley BS, Bedard NA, Bezwada HP, Hannon CP, Fillingham YA, Kolwadkar YV, Rees HW, Grosso MJ, Zeegen EN. What is the Level of Evidence Substantiating Commercial Payers' Coverage Policies for Total Joint Arthroplasty? J Arthroplasty 2021; 36:2665-2673.e8. [PMID: 33867209 DOI: 10.1016/j.arth.2021.03.036] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 03/08/2021] [Accepted: 03/14/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The prevalence of total joint arthroplasty (TJA) in the United States has drawn the attention of health care stakeholders. The payers have also used a variety of strategies to regulate the medical necessity of these procedures. The purpose of this study was to examine the level of evidence of the coverage policies being used by commercial payers in the United States. METHODS The references of the coverage policies of four commercial insurance companies were reviewed for type of document, level of evidence, applicability to a TJA population, and success of nonoperative treatment in patients with severe degenerative joint disease. RESULTS 282 documents were reviewed. 45.8% were primary journal articles, 14.2% were level I or II, 41.2% were applicable to patients who were candidates for TJA, and 9.9% discussed the success of nonoperative treatment in patients who would be candidates for TJA. CONCLUSION Most of the references cited by commercial payers are of a lower level of scientific evidence and not applicable to patients considered to be candidates for TJA. This is relatively uniform across the reviewed payers. The dearth of high-quality literature cited by commercial payers reflects the lack of evidence and difficulty in conducting high level studies on the outcomes of nonoperative versus operative treatment for patients with severe, symptomatic osteoarthritis. Patients, surgeons, and payers would all benefit from such studies and we encourage professional societies to strive toward that end through multicenter collaboration.
Collapse
Affiliation(s)
- Matthew S Austin
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Blair S Ashley
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Nicholas A Bedard
- Department of Orthopaedic Surgery, University of Iowa Hospitals & Clinics, Iowa City, IA
| | | | - Charles P Hannon
- Department of Orthopaedic Surgery, The Mayo Clinic, Ochester, MN
| | - Yale A Fillingham
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA
| | - Yogesh V Kolwadkar
- Department of Orthopaedic Surgery, VA Central California Health Care System, Fresno, CA
| | - Harold W Rees
- Department of Orthopaedic Surgery, Loyola University Medical Center, Maywood, IL
| | - Matthew J Grosso
- Department of Orthopaedic Surgery, Rothman Orthopaedic Institute at Thomas Jefferson University, Philadelphia, PA; Connecticut Joint Replacement Institute, Hartford, CT
| | - Erik N Zeegen
- Department of Orthopaedic Surgery, University of California Los Angeles, Santa Monica, CA
| |
Collapse
|
9
|
Chung KY, Cheung KW, Fan CH, Poon WC, Chiu KH, Ho KKW. Long-Term Outcome on the Mal-Seating of Ceramic-on-Ceramic Articulation in Total Hip Arthroplasty. J Arthroplasty 2021; 36:2100-2104. [PMID: 33573813 DOI: 10.1016/j.arth.2021.01.024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 01/04/2021] [Accepted: 01/11/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Total hip arthroplasty with ceramic-on-ceramic articulation aims to decrease wear, osteolysis, and aseptic loosening. A metal-backed ceramic liner was developed to reduce the risk of liner fracture. However, a significant number of cases of mal-seating of the metal-backed ceramic liner were observed in the 2000s, and there were concerns about their outcome. This review aims to investigate the long-term performance of the mal-seated ceramic liner. METHODS From July 2003 to March 2007, 35 ceramic-on-ceramic total hip arthroplasties were performed with the Trident acetabular system. Clinical assessment, radiological analysis, and outcome assessment were performed. The prevalence of liner mal-seating and its long-term outcomes were investigated. RESULTS There was liner mal-seating in 8 hips (22.9%). One liner was exchanged in the early postoperative period. No revision surgery was required for the remaining 7 hips at a mean follow-up of 14 years. All patients were free of hip pain with a mean Harris Hip Score of 94.7 at the most recent follow-up. No adverse event was observed. CONCLUSION The long-term outcomes of the mal-seated liner were favorable. However, surgeons should exercise meticulous surgical technique to achieve a properly aligned liner within the acetabular shell to minimize this potentially correctable error.
Collapse
Affiliation(s)
| | | | - Chi-Ho Fan
- Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Tai Po, Hong Kong
| | - Wai-Chin Poon
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
| | - Kwok-Hing Chiu
- Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Shatin, Hong Kong
| | - Kevin Ki-Wai Ho
- Department of Orthopaedics and Traumatology, The Chinese University of Hong Kong, Shatin, Hong Kong
| |
Collapse
|
10
|
Shankar S, Nithyaprakash R, Santhosh BR, Uddin MS, Pramanik A. Finite element submodeling technique to analyze the contact pressure and wear of hard bearing couples in hip prosthesis. Comput Methods Biomech Biomed Engin 2020; 23:422-431. [PMID: 32116045 DOI: 10.1080/10255842.2020.1734794] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Finite element (FE) simulation plays a major role in computing stress and predicting the failure of biomedical components. Normally in past, researchers focused on developing a global computational model from the scanned data of patients to analyze the stresses and deformations. To compute the wear of the hip prosthesis, mostly the global model (GM) is used to predict the expected life for million cycles using nodal updating technique which leads to high computational effort and time. The proposed work utilizes a submodeling finite element technique to analyze the contact pressure and wear of biomaterials for three different combinations in hip prosthesis including metal, ceramic and polycrystalline diamond materials. Initially the global model boundary and loading conditions are transferred to the submodel. The mesh is refined further using finer mesh and then the results are computed which consumes lesser time. The contact stress as well as the linear wear of biomaterials is found to be quite high for the local model (LM) when compared with the global model. However, no changes in volumetric wear of these biomaterials are observed when compared with previous experimental results. The computational time as well as accuracy in estimating the contact stress and the wear of bearings is improved effectively. Among local model with different element sizes, 0.75 mm element size of local model showed improved results in estimating the contact stress and linear wear of bearing.
Collapse
Affiliation(s)
- S Shankar
- Department of Mechatronics Engineering, Kongu Engineering College, Erode, Tamil Nadu, India
| | - R Nithyaprakash
- Department of Mechatronics Engineering, Kongu Engineering College, Erode, Tamil Nadu, India
| | - B R Santhosh
- Department of Mechanical Engineering, Kongu Engineering College, Erode, Tamil Nadu, India
| | - M S Uddin
- School of Engineering, University of South Australia, Adelaide, Australia
| | - Alokesh Pramanik
- School of Civil and Mechanical Engineering, Curtin University, Bentley, WA, Australia
| |
Collapse
|
11
|
BASHA SHAIKAKBAR, SARKAR DEBASISH. COMPETITIVE LIFE TIME ASSESSMENT OF SrO-ZTA/SrO-ZTA AND CoCrMo/UHMWPE HIP PROSTHESIS BEARINGS. J MECH MED BIOL 2020. [DOI: 10.1142/s0219519420500098] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The hip joint envisages the prime load bearing structure among other joints in the human body. Hip joint failure leads to the replacement of the hip joint prosthesis. This research work focuses on the proper selection of bearing couple materials for the hip joint to improve the performance and life. Herein, the stress and deformation of different bearing couple materials are analysed in the perspective of transient dynamic analysis under jogging load cycle. Selective hip joint bearing (femoral head-liner) couples are SS316L on UHMWPE (MoP), CoCrMo on UHMWPE (MoP), Ti6Al4V on SrO-ZTA (MoC), SrO-ZTA on UHMWPE (CoP) and SrO-ZTA on SrO-ZTA (CoC) encountered, respectively. The SrO-ZTA on SrO-ZTA (CoC) bearing couple generates the less Von Mises stress of 180.88 MPa. Load bearing pressure and Archard law predict the wear depth of CoCrMo on UHMWPE (MoP) and SrO-ZTA on SrO-ZTA (CoC) bearing couples are 0.141 mm/year and 0.031 mm/year, respectively. In simultaneous, the theoretical wear volume for CoCrMo on UHMWPE (MoP) and SrO-ZTA on SrO-ZTA (CoC) bearing couples are found as 35.46[Formula: see text]mm3/year and 2.62[Formula: see text]mm3/year, respectively. The wear depth and wear volume are supporting the available clinical retrievals and exist in well acceptable range. Competitive wear analysis data ensures 15 years safe life of SrO-ZTA on SrO-ZTA (CoC) hip prosthesis bearing.
Collapse
Affiliation(s)
- SHAIK AKBAR BASHA
- Department of Ceramic Engineering, National Institute of Technology, Rourkela, India
| | - DEBASISH SARKAR
- Department of Ceramic Engineering, National Institute of Technology, Rourkela, India
- HiLASE, Institute of Physics, ASCR, Prague, Czech Republic
| |
Collapse
|
12
|
Hallab NJ, Jacobs JJ. Orthopedic Applications. Biomater Sci 2020. [DOI: 10.1016/b978-0-12-816137-1.00070-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
13
|
[Total hip arthroplasty in young patients : Bearings and custom-made prostheses]. DER ORTHOPADE 2019; 48:292-299. [PMID: 30737518 DOI: 10.1007/s00132-019-03692-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
BACKGROUND Carefully and correctly implanted components are the prerequisite for the lifespan of a prosthesis. Whether higher levels of activity lead to prior failure of total hip arthroplasty in young patients is controversially discussed. The right choice of bearings is still of great relevance. BEARINGS Ceramic-on-ceramic as well as polyethylene-on-ceramic bearings achieve comparable results, although ceramic-on-ceramic bearings should be avoided in patients with high demands on their range of motion. Polyethylene-on-metal bearings also show good clinical results, if corrosion between head and stem is absent. Metal-on-metal bearings lead to adverse systemic effects due to metal wear and should be implanted in individual cases only, e. g. as hip resurfacing. Alternative bearings have to give proof of effectivity first. Custom-made prostheses constitute an option for young patients with special conditions of hip anatomy. Planning and study results of these prostheses are elucidated in this review article.
Collapse
|
14
|
Eltit F, Wang Q, Wang R. Mechanisms of Adverse Local Tissue Reactions to Hip Implants. Front Bioeng Biotechnol 2019; 7:176. [PMID: 31417898 PMCID: PMC6683860 DOI: 10.3389/fbioe.2019.00176] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 07/08/2019] [Indexed: 12/11/2022] Open
Abstract
Adverse Local Tissue Reactions (ALTRs) are one of the main causes of hip implant failures. Although the metal release from the implants is considered as a main etiology, the mechanisms, and the roles of the released products are topics of ongoing research. The alloys used in the hip implants are considered biocompatible and show negligible corrosion in the body environment under static conditions. However, modularity and its associated mechanically assisted corrosion have been shown to release metal species into the body fluids. ALTRs associated with metal release have been observed in hip implants with metal-on-metal articulation initially, and later with metal-on-polyethylene articulation, the most commonly used design in current hip replacement. The etiological factors in ALTRs have been the topics of many studies. One commonly accepted theory is that the interactions between the metal species and body proteins and cells generate a delayed type IV hypersensitivity reaction leading to ALTRs. However, lymphocyte reactions are not always observed in ALTRS, and the molecular mechanisms have not been clearly demonstrated. A more accepted mechanism is that cell damage generated by metal ions may trigger the secretion of cytokines leading to the inflammatory reactions observed in ALTRs. In this inflammatory environment, some patients would develop hypersensitivity that is associated with poor outcomes. Concerns over ALTRS have brought significant impact to both the clinical selection and development of hip implants. This review is focused on the mechanisms of ALTRs, specifically, the metal release process and the roles of the metal species released in the etiology and pathogenesis of the disease. Hopefully, our presentation and discussion of this biological process from a material perspective could improve our current understanding on the ALTRs and provide useful guidance in developing preventive solutions.
Collapse
Affiliation(s)
- Felipe Eltit
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Qiong Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| | - Rizhi Wang
- Department of Materials Engineering, University of British Columba, Vancouver, BC, Canada.,School of Biomedical Engineering, University of British Columba, Vancouver, BC, Canada.,Centre for Hip Health and Mobility, Vancouver, BC, Canada
| |
Collapse
|
15
|
Preliminary results of the tribological performance of new modular temporary knee spacer antibiotic-impregnated. J Mech Behav Biomed Mater 2019; 95:205-209. [DOI: 10.1016/j.jmbbm.2019.04.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2019] [Revised: 04/04/2019] [Accepted: 04/11/2019] [Indexed: 01/28/2023]
|
16
|
Hu CY, Yoon TR. Recent updates for biomaterials used in total hip arthroplasty. Biomater Res 2018; 22:33. [PMID: 30534414 PMCID: PMC6280401 DOI: 10.1186/s40824-018-0144-8] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2018] [Accepted: 10/03/2018] [Indexed: 12/23/2022] Open
Abstract
Background Total hip arthroplasty (THA) is probably one of the most successful surgical interventions performed in medicine. Through the revolution of hip arthroplasty by principles of low friction arthroplasty was introduced by Sir John Charnley in 1960s. Thereafter, new bearing materials, fixation methods, and new designs has been improved. The main concern regarding failure of THA has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfaces leading to osteolysis and aseptic loosening of the prosthesis. To resolve these problems, the materials of the modern THA were developed since then. Methods A literature search strategy was conducted using various search terms in PUBMED. The highest quality articles that met the inclusion criteria and best answered the topics of focus of this review were selected. Key search terms included ‘total hip arthroplasty’, ‘biomaterials’, ‘stainless steel’, ‘cobalt-chromium’, ‘titanium’, ‘polyethylene’, and ‘ceramic’. Results The initial search retrieved 6921 articles. Thirty-two articles were selected and used in the review. Conclusion This article introduces biomaterials used in THA and discusses various bearing materials in currentclinical use in THA as well as the newer biomaterials which may even further decrease wear and improve THA survivorship.
Collapse
Affiliation(s)
- Chang Yong Hu
- Center for Joint Disease, Chonnam National University Hwasun Hospital, 160, Ilsim-Ri, Hwasun-Eup, Hwasun-Gun, Jeonnam 519-809 South Korea
| | - Taek-Rim Yoon
- Center for Joint Disease, Chonnam National University Hwasun Hospital, 160, Ilsim-Ri, Hwasun-Eup, Hwasun-Gun, Jeonnam 519-809 South Korea
| |
Collapse
|
17
|
Askari E, Andersen MS. A closed-form formulation for the conformal articulation of metal-on-polyethylene hip prostheses: Contact mechanics and sliding distance. Proc Inst Mech Eng H 2018; 232:1196-1208. [DOI: 10.1177/0954411918810044] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Using Hertz contact law results in inaccurate outcomes when applied to the soft conformal hip implants. The finite element method also involves huge computational time and power. In addition, the sliding distance computed using the Euler rotation method does not incorporate tribology of bearing surfaces, contact mechanics and inertia forces. This study, therefore, aimed to develop a nonlinear dynamic model based on the multibody dynamic methodology to predict contact pressure and sliding distance of metal-on-polyethylene hip prosthesis, simultaneously, under normal walking condition. A closed-form formulation of the contact stresses distributed over the articulating surfaces was derived based upon the elastic foundation model, which reduced computational time and cost significantly. Three-dimensional physiological loading and motions, inertia forces due to hip motion and energy loss during contact were incorporated to obtain contact properties and sliding distance. Comparing the outcomes with that available in the literature and a finite element analysis allowed for the validation of our approach. Contours of contact stresses and accumulated sliding distances at different instants of the walking gait cycle were investigated and discussed. It was shown that the contact point at each instant was located within the zone with the corresponding highest accumulated sliding distance. In addition, the maximum contact pressure and area took place at the stance phase with a single support. The stress distribution onto the cup surface also conformed to the contact point trajectory and the physiological loading.
Collapse
Affiliation(s)
- Ehsan Askari
- Department of Materials and Production, Aalborg University, Aalborg, Denmark
| | - Michael S Andersen
- Department of Materials and Production, Aalborg University, Aalborg, Denmark
| |
Collapse
|
18
|
Martin JR, Jennings JM, Watters TS, Levy DL, Miner TM, Dennis DA. Midterm Prospective Comparative Analysis of 2 Hard-on-Hard Bearing Total Hip Arthroplasty Designs. J Arthroplasty 2018; 33:1820-1825. [PMID: 29429884 DOI: 10.1016/j.arth.2018.01.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2017] [Revised: 01/15/2018] [Accepted: 01/17/2018] [Indexed: 02/01/2023] Open
Abstract
INTRODUCTION Hard-on-hard (HoH) bearing surfaces in total hip arthroplasty (THA) are commonly utilized in younger patients and may decrease mechanical wear compared to polyethylene bearing surfaces. To our knowledge, no study has prospectively compared the 2 most common HoH bearings, ceramic-on-ceramic (CoC) and metal-on-metal (MoM) THA. MATERIALS AND METHODS We prospectively enrolled 40 patients to undergo an MoM THA and 42 patients to undergo a CoC THA utilizing the same acetabular component. Patients were followed up for a minimum of 2 years. Comparative outcomes included clinical scores, revision or reoperation for any reason, complication rates, and radiographic outcomes. RESULTS The average follow-up was significantly longer in the CoC cohort (94 vs 74 months; P = .005). The CoC cohort had significantly improved Harris Hip Scores (95 vs 84; P = .0009) and pain scores (42 vs 34; P = .0003). The revision (0% vs 31%; P = .0001), reoperation (7.5% vs 36%; P = .004), and complication rates (10% vs 56%; P = .0001) were significantly lower in the CoC cohort. There were no statistically significant differences in radiographic parameters. CONCLUSION The clinical outcomes in the CoC cohort exceeded the MoM cohort. It is unlikely that another prospective comparative study of HoH THAs will be conducted. Our midterm results support the use of CoC THA as a viable option that may reduce long-term wear in younger patients. Close surveillance of MoM THA patients is recommended considering the higher failure and complication rates reported in this cohort.
Collapse
Affiliation(s)
| | | | | | | | | | - Douglas A Dennis
- Colorado Joint Replacement, Denver, CO; Department of Biomedical Engineering, University of Tennessee, Knoxville, TN; Bioengineering, University of Denver, Denver, CO; Department of Orthopaedics, University of Colorado School of Medicine, Denver, CO
| |
Collapse
|
19
|
Liu F, Feng L, Wang J. A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements. J Mech Behav Biomed Mater 2018; 83:135-142. [PMID: 29704828 DOI: 10.1016/j.jmbbm.2018.04.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2018] [Revised: 03/24/2018] [Accepted: 04/19/2018] [Indexed: 10/17/2022]
Abstract
Edge loading in ceramic-on-ceramic total hip joint replacement is an adverse condition that occurs as the result of a direct contact between the head and the cup rim. It has been associated with translational mismatch in the centres of rotation of the cup and head, and found to cause severe wear and early failure of the implants. Edge loading has been considered in particular in relation to dynamic separation of the cup and head centres during a gait cycle. Research has been carried out both experimentally and computationally to understand the mechanism including the influence of bearing component positioning on the occurrence and severity of edge loading. However, it is experimentally difficult to measure both the load magnitude and duration of edge loading as it occurs as a short impact within the tight space of hip joints. Computationally, a dynamic contact model, for example, developed using the MSC ADAMS software for a multi-body dynamics simulation can be particularly useful for calculating the loads and characterising the edge loading. The aim of the present study was to further develop the computational model, and improve the predictions of contact force and the understanding of mechanism in order to provide guidance on design and surgical factors to avoid or to reduce edge loading and wear. The results have shown that edge loading can be avoided for a low range of translational mismatch in the centres of rotation of the cup and head during gait at the level of approximately 1.0 mm for a cup at 45° inclination, keeping a correct cup inclination at 45° is important to reduce the edge loading severity, and edge loading can be avoided for a certain range of translational mismatch of the cup and head centres with an increased swing phase load.
Collapse
Affiliation(s)
- Feng Liu
- School of Mechanical Engineering, North University of China, PR China.
| | - Li Feng
- School of Mechanical Engineering, North University of China, PR China
| | - Junyuan Wang
- School of Mechanical Engineering, North University of China, PR China
| |
Collapse
|
20
|
Grieco PW, Pascal S, Newman JM, Shah NV, Stroud SG, Sheth NP, Maheshwari AV. New alternate bearing surfaces in total hip arthroplasty: A review of the current literature. J Clin Orthop Trauma 2018; 9:7-16. [PMID: 29628677 PMCID: PMC5884051 DOI: 10.1016/j.jcot.2017.10.013] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 10/26/2017] [Indexed: 01/01/2023] Open
Abstract
As indications for total hip arthroplasty (THA) have expanded, the incidence of THA has increased among younger patients, who live longer and tend to place more strain on implants via higher activity levels. This demographical shift accentuates the importance of advancing innovation to ensure implant longevity for younger and more active patients. Future innovation, as it pertains to THA components, is likely to focus on modifying implant designs and tribology in conjunction with identification and application of newer biomaterials. By reviewing the literature for development status of various materials and novel design advancements in THA component outside of the standard highly cross-linked polyethylene, this investigation provided an update on the current and future status of design initiatives as they pertain to THA. Though the highlighted alternative bearing surfaces have shown promising in vitro and limited, yet encouraging clinical data, they lack larger and longer-term clinical trial results. Further research and innovation is warranted to identify the optimal bearing surface to most effectively accommodate for the trend of younger and more active patients undergoing THA. Implant longevity is crucial if the clinical success of THA is to be maintained.
Collapse
Affiliation(s)
- Preston W. Grieco
- Department of Orthopaedic Surgery, State University of New York, Downstate Medical Center, Brooklyn, NY 11203, USA
| | - Scott Pascal
- Department of Orthopaedic Surgery, State University of New York, Downstate Medical Center, Brooklyn, NY 11203, USA
| | - Jared M. Newman
- Department of Orthopaedic Surgery, State University of New York, Downstate Medical Center, Brooklyn, NY 11203, USA
| | - Neil V. Shah
- Department of Orthopaedic Surgery, State University of New York, Downstate Medical Center, Brooklyn, NY 11203, USA
| | - Sarah G. Stroud
- Department of Orthopaedic Surgery, State University of New York, Downstate Medical Center, Brooklyn, NY 11203, USA
| | - Neil P. Sheth
- Department of Orthopaedic Surgery, Hospital of the University of Pennsylvania, 1 Cathcart 800 Spruce Street, Philadelphia, PA 19107, USA
| | - Aditya V. Maheshwari
- Department of Orthopaedic Surgery, State University of New York, Downstate Medical Center, Brooklyn, NY 11203, USA,Corresponding author at: Adult Reconstruction and Musculoskeletal Oncology Divisions SUNY Downstate Medical Center 450 Clarkson Ave., Box 3 Box 3 Box 30 Brooklyn, NY 11203, USA.
| |
Collapse
|
21
|
Liu F, Fisher J. Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints. TRIBOLOGY INTERNATIONAL 2017; 113:323-329. [PMID: 28867870 PMCID: PMC5465945 DOI: 10.1016/j.triboint.2017.01.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Revised: 01/09/2017] [Accepted: 01/10/2017] [Indexed: 06/07/2023]
Abstract
Alumina ceramic total hip joint bearings have shown superior wear properties. The joint bearing may undergo adverse conditions such as micro-separation causing head contact on the cup rim. As a transition, an edge is formed between the cup bearing and the rim. The aim of this study was to predict the effect of the edge on contact stresses in order to better understand the mechanisms of wear. A finite element contact model was developed under the conditions of the head displacements 0.5-2 mm and vertical loads 0.5-3 kN. The edge contact produced the most severe stresses capable of causing elevated wear and damage to ceramic bearings. The study shows that the bearing design should be considered in association with clinical conditions to eliminate severe stress.
Collapse
Affiliation(s)
- Feng Liu
- School of Mechanical and Power Engineering, North University of China, PR China
| | - John Fisher
- Institute of Medical and Biological Engineering School of Mechanical Engineering, University of Leeds,UK
| |
Collapse
|
22
|
Schmidt-Braekling T, Renner L, Mintz DN, Waldstein W, Endo Y, Boettner F. Do Changes in the Production Process Affect the Outcome of Ceramic Liners: A 3-Year Follow-Up Study. J Arthroplasty 2017; 32:1314-1317. [PMID: 27876256 DOI: 10.1016/j.arth.2016.10.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Revised: 09/24/2016] [Accepted: 10/09/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND In 2011, the current liner was withdrawn from the market because of the potential risk for liner fracture secondary to increased pressures used to assemble the metal locking ring. The present study provides a short-term follow-up of patients with this implant. METHODS We retrospectively evaluated 63 consecutive hips in 53 patients operated by a single surgeon using a recalled ceramic-on-ceramic bearing. There were 30 women and 23 men with an average age of 50.6 years (range 20.3-63.5 years). The mean follow-up was 36.8 months. RESULTS Six hips in 6 patients were revised (9.5%) because of a liner-fracture during the follow-up period. All liner fractures were identified on computer tomography imaging. Nine patients had self-reported episodes of squeaking (14.3%). All 6 patients that underwent revision surgery for liner fracture described squeaking before revision. There were no revisions for other causes. Two of the revised patients had a subsequent dislocation (33%). CONCLUSION The recalled ceramic liner lots have an increased liner fracture rate. Patients with mechanical symptoms or squeaking should undergo computer tomography to rule out liner facture.
Collapse
Affiliation(s)
- Tom Schmidt-Braekling
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York; Department of Orthopedics and Tumor Orthopedics, University of Muenster, Muenster, Germany
| | - Lisa Renner
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York
| | - Douglas N Mintz
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | - Wenzel Waldstein
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York; Department of Orthopedics, Vienna General Hospital, Medical University of Vienna, Vienna, Austria
| | - Yoshimi Endo
- Department of Radiology and Imaging, Hospital for Special Surgery, New York, New York
| | - Friedrich Boettner
- Adult Reconstruction & Joint Replacement Division, Hospital for Special Surgery, New York, New York
| |
Collapse
|
23
|
Abstract
Articulating components should minimise the generation of wear particles in order to optimize long-term survival of the prosthesis. A good understanding of tribological properties helps the orthopaedic surgeon to choose the most suitable bearing for each individual patient. Conventional and highly cross-linked polyethylene articulating either with metal or ceramic, ceramic-on-ceramic and metal-on-metal are the most commonly used bearing combinations. All combinations of bearing surface have their advantages and disadvantages. An appraisal of the individual patient’s objectives should be part of the assessment of the best bearing surface.
Cite this article: Rieker CB. Tribology of total hip arthroplasty prostheses: what an orthopaedic surgeon should know. EFORT Open Rev 2016;1:52-57. DOI: 10.1302/2058-5241.1.000004.
Collapse
|
24
|
ZHANG XUAN, WANG LING, PENG XIFENG, LI DICHEN, HE JIANKANG, LIU YAXIONG, LIAN QIN, JIN ZHONGMIN, LIU CHAOZONG. THE EFFECT OF ASPHERICITY OF ACETABULAR BEARING SURFACE ON CONTACT MECHANICS OF UHMWPE TOTAL HIP IMPLANTS BY FINITE ELEMENT ANALYSIS. J MECH MED BIOL 2017. [DOI: 10.1142/s0219519417500117] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Asphericity and out-of-roundness are generally used to evaluate the manufacturing quality of ultra-high molecular weight polyethylene (UHMWPE) cup inner surfaces, which can potentially affect initial clinical wear and contribute to osteolysis of total hip arthroplasty. This study measured the location and magnitude of asphericity and the out-of-roundness value for four UHMWPE cups in a single set, and then investigated the effects of the asphericity on the contact mechanics of UHMWPE cups. A co-ordinate measuring machine (CMM) was used for the surface measurement and finite element analysis (FEA) was adopted for contact mechanics study. The results demonstrated that the asphericity varied between cups with the maximum value as 0.088[Formula: see text][Formula: see text][Formula: see text]0.004[Formula: see text]mm. Although such a value met the ISO specification, large difference of volume appeared for the asphericity above 0.060[Formula: see text]mm. Actual surface profile accounting for the asphericity was found to affect the value of contact pressure and contact area by around 12%. The inferior asphericity resulted in a nonsmoothly distributed contact pressure, which had a negative effect on the contact mechanics of UHMWPE cups and the edge loading was predicted to occur for the sample with a large asphericity. In conclusion, the asphericity of UHMWPE cup could affect the contact mechanics of the articular bearings and may subsequently contribute to initial wear during bedding-in phase.
Collapse
Affiliation(s)
- XUAN ZHANG
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - LING WANG
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - XIFENG PENG
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - DICHEN LI
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - JIANKANG HE
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - YAXIONG LIU
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - QIN LIAN
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
| | - ZHONGMIN JIN
- State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, P. R. China
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, LS2 9JT, UK
| | - CHAOZONG LIU
- John Scales Centre for Biomedical Engineering, Royal National Orthopaedic Hospital, University College London, Stanmore, HA7 4LP, London, UK
| |
Collapse
|
25
|
Lee SJ, Yoo JJ, Kim HJ. Cementless Total Hip Arthroplasty Involving Trochanteric Osteotomy without Subtrochanteric Shortening for High Hip Dislocation. Clin Orthop Surg 2017; 9:19-28. [PMID: 28261423 PMCID: PMC5334023 DOI: 10.4055/cios.2017.9.1.19] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Accepted: 09/20/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Total hip arthroplasty with subtrochanteric shortening osteotomy is widely performed for high hip dislocation. However, suboptimal leg length discrepancy correction and nonunion of the osteotomy site remain concerns. Although total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy was introduced, cemented implants have been more commonly used than contemporary cementless implants in this procedure. We evaluated the long-term results of cementless total hip arthroplasty with trochanteric osteotomy without subtrochanteric osteotomy for high hip dislocation. METHODS From 1990 to 2002, 27 cementless total hip arthroplasties using trochanteric osteotomy without subtrochanteric osteotomy were performed in 26 patients with Crowe III or IV high hip dislocation and a mean age of 36.4 ± 12.9 years. Seven ceramic-on-ceramic, 8 ceramic-on-polyethylene, 10 metal-on-polyethylene, and 2 metal-on-metal bearings were inserted. Mean follow-up was 15.1 ± 3.7 years. We retrospectively reviewed medical records and radiographic data and evaluated the clinical and radiological results including the Harris hip score, implant survival, correction of leg length discrepancy, and occurrence of complications. RESULTS The mean Harris hip score and leg length discrepancy improved significantly from 73.3 to 94.9 points and from 4.3 cm to 1.0 cm, respectively. With revision for loosening set as the end point, implant survival rates at 10 and 15 years postoperatively were 96.0% and 90.9% for stems and 74.1% and 52.3% for cups. In 8 of 10 hips with the metal-on-polyethylene bearing and 4 of 8 hips with the ceramic-on-polyethylene bearing, revision surgery was performed for aseptic loosening. However, no revision was performed in hips with the ceramic-on-ceramic bearing or the metal-on-metal bearing. Implant survival was significantly different by the type of bearing surface. Two permanent neurologic complications occurred in patients with a limb lengthening over 3.5 cm. CONCLUSIONS With proper selection of the bearing surface coupled with adjustment of lengthening, cementless total hip arthroplasty using trochanteric osteotomy without subtrochanteric osteotomy might be a favorable treatment option for high hip dislocation.
Collapse
Affiliation(s)
- Soong Joon Lee
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Jeong Joon Yoo
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| | - Hee Joong Kim
- Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul, Korea
| |
Collapse
|
26
|
Is micro-computed tomography useful for wear assessment of ceramic femoral heads? A preliminary evaluation of volume measurements. J Appl Biomater Funct Mater 2016; 14:e483-e489. [PMID: 27647391 DOI: 10.5301/jabfm.5000324] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/01/2016] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND Wear associated with hip components represents the main clinical problem in these patients, and it is important to develop new techniques for more accurate measurements of that wear. Currently, the gravimetric method is the gold standard for assessing mass measurements in preclinical evaluations. However, this method does not give other information such as volumetric loss or surface deviation. This work aimed to develop and validate a new technique to quantify ceramic volume loss from in vitro experiments using micro-computed tomography (micro-CT). METHODS An alumina (BIOLOX® forte) femoral head (Ø = 28 mm) was used. Mass and volume loss were approached by gravimetric method (using a four decimal place digital microbalance) and by using Skyscan 1176 microtomographic system, respectively. RESULTS Standard error and coefficient of variance of both gravimetric and experimental groups demonstrated the reliability of the micro-CT analysis technique. CONCLUSIONS In conclusion, the findings of the present study suggest that this new protocol could be considered an important tool for wear assessment and that we have found a reliable metrological protocol for volumetric analysis of ceramic femoral head prostheses, demonstrating that the micro-CT technique can be an important tool for wear assessment.
Collapse
|
27
|
Haider H, Weisenburger JN, Garvin KL. Simultaneous measurement of friction and wear in hip simulators. Proc Inst Mech Eng H 2016; 230:373-88. [DOI: 10.1177/0954411916644476] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2015] [Accepted: 03/02/2016] [Indexed: 11/15/2022]
Abstract
We propose and have evaluated a method to measure hip friction during wear testing on a popular multi-station hip simulator. A 6-degree-of-freedom load cell underneath the specimen sensed forces and torques during implant wear testing of simulated walking. This included internal–external and adduction–abduction rotations which are often neglected during friction testing on pendulum-type machines. Robust mathematical analysis and data processing provided friction estimates in three simultaneous orthogonal rotations, over extended multi-million cycle wear tests. We tested various bearing couples including metal-on-plastic, ceramic-on-plastic, and metal-on-metal material couples. In one test series, new and intentionally scratched CoCrMo 40-mm-diameter femoral heads were tested against conventional ultrahigh-molecular-weight polyethylene, highly cross-linked, and highly cross-linked with vitamin E versions. The scratching significantly increased friction and doubled the wear of all groups. Before scratching, friction levels for the aforementioned plastic groups were 0.056 ± 0.0060, 0.062 ± 0.0080, and 0.070 ± 0.0045, respectively, but after scratching increased to 0.088 ± 0.018, 0.076 ± 0.0066, and 0.082 ± 0.0049, respectively, all statistically significant increases (p = 0.00059, 0.00005, 0.0115, respectively). In another test series of 44-mm femoral head diameter hips, metal-on-plastic hips with conventional ultrahigh-molecular-weight polyethylene showed the lowest friction at 0.045 ± 0.0085, followed by highly cross-linked with 0.046 ± 0.0035 (not significantly different). In a ceramic-on-plastic design with conventional ultrahigh-molecular-weight polyethylene, higher friction 0.079 ± 0.0070 was measured likely due to that ceramic surface being rougher than usual. Metal-on-metal hips were compared without and with a TiN coating, resulting in 0.049 ± 0.014 and 0.097 ± 0.020 friction factors, respectively (statistically significant, p < 0.001), and the coating wore away on all coated hips eventually. Higher friction mostly correlated with higher wear or damage to femoral heads or implant coatings, except for the highly cross-linked wear resistant ultrahigh-molecular-weight polyethylene which had slightly higher friction, confirming the same finding in other independent studies. This type of friction measurements can help screen for clamping and elevated wear of metal-on-metal and resurfacing total hip replacements, surgical malpositioning, and abraded and otherwise damaged surfaces.
Collapse
Affiliation(s)
- Hani Haider
- Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, Omaha, NE, USA
| | - Joel N Weisenburger
- Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, Omaha, NE, USA
| | - Kevin L Garvin
- Department of Orthopaedic Surgery and Rehabilitation, University of Nebraska Medical Center, Omaha, NE, USA
| |
Collapse
|
28
|
Baker PA, Thompson RG, Catledge SA. A wear simulation study of nanostructured CVD diamond-on-diamond articulation involving concave/convex mating surfaces. JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH 2016; 13:385-393. [PMID: 26989457 PMCID: PMC4790821 DOI: 10.1007/s11998-015-9738-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Using microwave-plasma Chemical Vapor Deposition (CVD), a 3-micron thick nanostructured-diamond (NSD) layer was deposited onto polished, convex and concave components that were machined from Ti-6Al-4V alloy. These components had the same radius of curvature, 25.4mm. Wear testing of the surfaces was performed by rotating articulation of the diamond-deposited surfaces (diamond-on-diamond) with a load of 225N for a total of 5 million cycles in bovine serum resulting in polishing of the diamond surface and formation of very shallow, linear wear grooves of less than 50nm depth. The two diamond surfaces remained adhered to the components and polished each other to an average surface roughness that was reduced by as much as a factor of 80 for the most polished region located at the center of the condyle. Imaging of the surfaces showed that the initial wearing-in phase of diamond was only beginning at the end of the 5 million cycles. Atomic force microscopy, scanning electron microscopy, Raman spectroscopy, and surface profilometry were used to characterize the surfaces and verify that the diamond remained intact and uniform over the surface, thereby protecting the underlying metal. These wear simulation results show that diamond deposition on Ti alloy has potential application for joint replacement devices with improved longevity over existing devices made of cobalt chrome and ultra-high molecular weight polyethylene (UHMWPE).
Collapse
Affiliation(s)
- Paul A Baker
- Vista Engineering, 1500 1st. Ave N. Unit 14, Birmingham, AL 35203 USA
| | | | - Shane A Catledge
- University of Alabama at Birmingham, 1720 2nd Ave. S, Birmingham, AL 35233 USA
| |
Collapse
|
29
|
Marques EMR, Humphriss R, Welton NJ, Higgins JPT, Hollingworth W, Lopez-Lopez JA, Thom H, Hunt LP, Blom AW, Beswick AD. The choice between hip prosthetic bearing surfaces in total hip replacement: a protocol for a systematic review and network meta-analysis. Syst Rev 2016; 5:19. [PMID: 26831503 PMCID: PMC4736145 DOI: 10.1186/s13643-016-0189-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Accepted: 01/13/2016] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Prosthetic hip implants have many combinations of bearing surface materials, sizes, and fixation techniques, which can determine the quality of life of patients after primary total hip replacement (THR) and the likelihood of needing revision surgery. When an implant fails, patients require revision THR, which is distressing to the patient and expensive for the health care payer. Primary THR is one of the most common elective procedures performed worldwide, with over 300,000 performed annually in the USA and over 80,000 in England and Wales. It is important to review all available randomised controlled trial (RCT) evidence to determine which implant bearing surface materials, size, and fixation technique are most effective for patients. METHODS/DESIGN This is a protocol for a systematic review and meta-analysis of RCTs comparing outcomes of hip implant bearing surfaces, size, and fixation techniques used in THR. Implant combinations compared in the literature include four bearing surface combinations (metal-on-polyethylene, metal-on-metal, ceramic-on-polyethylene, and ceramic-on-ceramic); two femoral head sizes (large vs small heads); and four fixation techniques (uncemented, cemented, hybrid, and reverse hybrids). The primary outcome will be revision surgery. We will also collect data on patient characteristics, mortality, quality of life, and other outcomes. In network meta-analysis, we will estimate the relative effectiveness of every implant bearing surface, head size (large vs small), and fixation permutation, using evidence where implants have been compared directly in an RCT and indirectly through common comparators in different RCTs. DISCUSSION There has been much debate about materials used for prosthetic implants in THR. Different combinations of prosthetic materials, sizes, and fixation, can vary widely in cost and fail at different rates for different patient groups. Given the number of THRs performed yearly, and the increasing use of expensive implants, it is important to review evidence to inform surgeons, patients, and health care providers of optimal implant bearing combinations for given patient characteristics. This review will inform a cost-effectiveness model that will include evidence from other sources, to determine the most effective and cost-effective implant bearing combination for patients. SYSTEMATIC REVIEW REGISTRATION PROSPERO CRD42015019435.
Collapse
Affiliation(s)
- Elsa M R Marques
- School of Social and Community Medicine, University of Bristol Canynge Hall, 39 Whatley Road, Bristol, BS8 2PS, UK.
| | - Rachel Humphriss
- School of Social and Community Medicine, University of Bristol Canynge Hall, 39 Whatley Road, Bristol, BS8 2PS, UK.
| | - Nicky J Welton
- School of Social and Community Medicine, University of Bristol Canynge Hall, 39 Whatley Road, Bristol, BS8 2PS, UK.
| | - Julian P T Higgins
- School of Social and Community Medicine, University of Bristol Canynge Hall, 39 Whatley Road, Bristol, BS8 2PS, UK.
| | - William Hollingworth
- School of Social and Community Medicine, University of Bristol Canynge Hall, 39 Whatley Road, Bristol, BS8 2PS, UK.
| | - Jose A Lopez-Lopez
- School of Social and Community Medicine, University of Bristol Canynge Hall, 39 Whatley Road, Bristol, BS8 2PS, UK.
| | - Howard Thom
- School of Social and Community Medicine, University of Bristol Canynge Hall, 39 Whatley Road, Bristol, BS8 2PS, UK.
| | - Linda P Hunt
- Musculoskeletal Research Unit, School of Clinical Sciences, University of Bristol Learning & Research Building (Level 1), Southmead Hospital, Bristol, BS10 5NB, UK.
| | - Ashley W Blom
- Musculoskeletal Research Unit, School of Clinical Sciences, University of Bristol Learning & Research Building (Level 1), Southmead Hospital, Bristol, BS10 5NB, UK.
| | - Andrew D Beswick
- Musculoskeletal Research Unit, School of Clinical Sciences, University of Bristol Learning & Research Building (Level 1), Southmead Hospital, Bristol, BS10 5NB, UK.
| |
Collapse
|
30
|
Boomsma MF, Slouwerhof I, van Lingen C, Pakvis DFM, van Dalen JA, Edens MA, Ettema HB, Verheyen CCPM, Maas M. CT-based quantification of bone stock in large head metal-on-metal unilateral total hip replacements. Eur J Radiol 2016; 85:760-3. [PMID: 26971420 DOI: 10.1016/j.ejrad.2016.01.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Revised: 11/06/2015] [Accepted: 01/21/2016] [Indexed: 11/16/2022]
Abstract
PURPOSE To explore ipsilateral and contralateral acetabular roof bone stock density in unilateral large head MoM THA whether there is a significant lower acetabular bone stock in the hip with a metal-on-metal (MoM) total hip replacement compared to the contralateral side. Second part of this study is to examine if there are any associates with regard to potential bone stock density difference. MATERIALS & METHODS A database of 317 patients with unilateral metal-on-metal (MoM) total hip replacements was set up retrospectively for this study. On computed tomography scans, conducted after a relative short in situ time period averaging 2.8 years, regions-of-interests were drawn in the trabecular bone of the acetabulum to measure average Hounsfield Units (HU). HU differences were calculated and tested by Wilcoxon signed-rank test. Univariate analysis was conducted to examine associates of potential bone loss. RESULTS In a population of 317 patients (156 male, 161 female) with an average age of 61.9 ± 7.8, the median HU on the side of the MoM replacement was 123.3 (7.6-375.4). On the contralateral side, median HU was 144.7 (-0.4 to 332.8). The median HU difference was 21.4 after a mean post-operative in situ time of 2.8 years. The Wilcoxon signed-rank test proved a significant difference (p<0.001). Univariate analyses show that the in situ time of the MoM THA has a significant correlation with the bone density difference. CONCLUSION Results show a significant lower bone density at the acetabular roof at the side of the prosthesis compared with the contralateral side after short in situ time of the MoM THA in patients with unilateral MoM total hip replacements. In our patient population, the in situ time showed a significant association with the acetabular bone density difference. As acetabular roof bone stock measurements are feasible and show temporal decline this could become an important parameter to be used in orthopedic decision making for revision surgery.
Collapse
Affiliation(s)
- Martijn F Boomsma
- Department of Radiology, Isala, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands.
| | - Inge Slouwerhof
- Department of Radiology, Isala, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands.
| | - Christiaan van Lingen
- Department of Orthopedic surgery and Traumatology, Isala, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands.
| | - Dean F M Pakvis
- Orthopedic Centre OCON, Geerdinksweg 141 7555 DL, Almelo/Hengelo, The Netherlands.
| | - Jorn A van Dalen
- Department of Radiology, Isala, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands.
| | - Mireille A Edens
- Department of Innovation and Science, Isala, Dokter van Deenweg 1, 8025 BP Zwolle, The Netherlands.
| | - Harmen B Ettema
- Department of Orthopedic surgery and Traumatology, Isala, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands.
| | - Cees C P M Verheyen
- Department of Orthopedic surgery and Traumatology, Isala, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands.
| | - Mario Maas
- Department of Radiology, AMC, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.
| |
Collapse
|
31
|
Wang T, Sun JY, Zha GC, Dong SJ, Zhao XJ. Mid term results of total hip arthroplasty using polyethylene-ceramic composite (Sandwich) liner. Indian J Orthop 2016; 50:10-5. [PMID: 26952027 PMCID: PMC4759864 DOI: 10.4103/0019-5413.173512] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND Ceramic-on-ceramic (COC) couplings are an attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. However, the material in total hip arthroplasty (THA) remains one of the major concern regarding the risk of fracture. The present study aims at reporting the fracture rate of bearings in a series of COC THAs with the use of a sandwich liner and attempt to detect the relative risk factors, the possible cause and assess the clinical results. MATERIALS AND METHODS We retrospectively evaluated 153 patients (163 hips) using the sandwich liner COC THA between 2001 and 2009. Patient assessment was based on demographic factors, including age, weight, gender and body-mass index (BMI). All patients were evaluated clinically and radiographically or using computed tomography viz-a-viz dislocation, osteolysis, periprosthetic fracture, infection, loosening and implant fracture. RESULTS Three ceramic sandwich liners fracture (1.84%) were observed at an average of 7.3 years' followup. The factors which were found to be non-significant to the ceramic liner fracture, included age (P = 0.205), weight (P = 0.241), gender (P = 0.553), BMI (P = 0.736), inclination (P = 0.199) and anteversion (P = 0.223). The overall survival was 91.4% at 12-year with revision as the endpoint. Other complications included osteolysis in 4 (2.45%), dislocation in one and periprosthetic fracture in one. In no hip aseptic loosening of the implants was seen. CONCLUSIONS Our experience with the ceramic-polyethylene sandwich liner acetabular component has been disappointing because of the high rate of fracture and osteolyis. We have discontinued the use of this device and recommend the same.
Collapse
Affiliation(s)
- Tao Wang
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou, Jiangsu 215006, P. R, China
| | - Jun-Ying Sun
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou, Jiangsu 215006, P. R, China,Address for correspondence: Dr. Jun-Ying Sun, Department of Orthopaedics, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou, Jiangsu 215006, P. R. China. E-mail:
| | - Guo-Chun Zha
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou, Jiangsu 215006, P. R, China
| | - Sheng-Jie Dong
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou, Jiangsu 215006, P. R, China
| | - Xi-Jiang Zhao
- Department of Orthopaedics, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou, Jiangsu 215006, P. R, China
| |
Collapse
|
32
|
Surface and Subsurface Analyses of Metal-on-Polyethylene Total Hip Replacement Retrievals. Ann Biomed Eng 2015; 44:1685-97. [DOI: 10.1007/s10439-015-1462-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2015] [Accepted: 09/14/2015] [Indexed: 10/23/2022]
|
33
|
Carvajal Alba JA, Elpers ME, Rosenberg AE, Robinson RP. Suboptimal Component Position Leading to Severe Wear of an Alumina-Alumina Total Hip Coupling: Biomechanical Analysis and Documentation of Limited Tissue Response. HSS J 2015; 11:166-71. [PMID: 26140037 PMCID: PMC4481258 DOI: 10.1007/s11420-015-9443-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2014] [Accepted: 03/24/2015] [Indexed: 02/07/2023]
Affiliation(s)
- Jaime A. Carvajal Alba
- />Department of Orthopaedic Surgery, University of Miami, 1611 N.W. 12th Ave, Suite 303, Miami, FL 33136 USA
| | - Marcella E. Elpers
- />Department of Biomechanics, Hospital for Special Surgery, 535 East 70th Street, New York, NY 10021 USA
| | | | - Raymond P. Robinson
- />Department of Orthopaedic Surgery, University of Miami, 1611 N.W. 12th Ave, Suite 303, Miami, FL 33136 USA
| |
Collapse
|
34
|
Green NC, Bowen J, Hukins DWL, Shepherd DET. Assessment of non-contacting optical methods to measure wear and surface roughness in ceramic total disc replacements. Proc Inst Mech Eng H 2015; 229:245-54. [PMID: 25834000 DOI: 10.1177/0954411915577119] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
This study presents a method for measuring the low volumetric wear expected in ceramic total disc replacements, which can be used to replace intervertebral discs in the spine, using non-contacting optical methods. Alumina-on-alumina ball-on-disc tests were conducted with test conditions approximating those of cervical (neck region of the spine) total disc replacement wear tests. The samples were then scanned using a three-dimensional non-contacting optical profilometer and the data used to measure surface roughness and develop a method for measuring the wear volume. The results showed that the magnification of the optical lens affected the accuracy of both the surface roughness and wear volume measurements. The method was able to successfully measure wear volumes of 0.0001 mm(3), which corresponds to a mass of 0.0001 mg, which would have been undetectable using the gravimetric method. A further advantage of this method is that with one scan the user can measure changes in surface topography, volumetric wear and the location of the wear on the implant surface. This method could also be applied to more severe wear, other types of orthopaedic implants and different materials.
Collapse
Affiliation(s)
- Naomi C Green
- School of Mechanical Engineering, University of Birmingham, Birmingham, UK
| | - James Bowen
- School of Chemical Engineering, University of Birmingham, Birmingham, UK
| | - David W L Hukins
- School of Mechanical Engineering, University of Birmingham, Birmingham, UK
| | | |
Collapse
|
35
|
Varnum C, Pedersen AB, Kjærsgaard-Andersen P, Overgaard S. Comparison of the risk of revision in cementless total hip arthroplasty with ceramic-on-ceramic and metal-on-polyethylene bearings. Acta Orthop 2015; 86:477-84. [PMID: 25637339 PMCID: PMC4513604 DOI: 10.3109/17453674.2015.1012975] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Accepted: 12/30/2014] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Ceramic-on-ceramic (CoC) bearings were introduced in total hip arthroplasty (THA) to reduce problems related to polyethylene wear. We compared the 9-year revision risk for cementless CoC THA and for cementless metal-on-polyethylene (MoP) THA. PATIENTS AND METHODS In this prospective, population-based study from the Danish Hip Arthroplasty Registry, we identified all the primary cementless THAs that had been performed from 2002 through 2009 (n = 25,656). Of these, 1,773 THAs with CoC bearings and 9,323 THAs with MoP bearings were included in the study. To estimate the relative risk (RR) of revision, we used regression with the pseudo-value approach and treated death as a competing risk. RESULTS 444 revisions were identified: 4.0% for CoC THA (71 of 1,773) and 4.0% for MoP THA (373 of 9,323). No statistically significant difference in the risk of revision for any reason was found for CoC and MoP bearings after 9 years of follow-up (adjusted RR = 1.3, 95% CI: 0.72-2.4). Revision rates due to component failure were 0.5% (n = 8) for CoC bearings and 0.1% (n = 6) for MoP bearings (p < 0.001). 6 patients with CoC bearings (0.34%) underwent revision due to ceramic fracture. INTERPRETATION When compared to the "standard" MoP bearings, CoC THA had a 33% higher (though not statistically significantly higher) risk of revision for any reason at 9 years.
Collapse
Affiliation(s)
- Claus Varnum
- Department of Orthopedic Surgery and Traumatology , Odense University Hospital , Odense
| | | | | | | |
Collapse
|
36
|
Abstract
BACKGROUND Bipolar hip arthroplasty (BHA) is one of the options for treatment of avascular necrosis (AVN) of the femoral head. Acetabular erosion and groin pain are the most allowing for gross motion between the common complications. We propose that these complications are secondary to improper acetabular preparation allowing for motion between the BHA head and the acetabulum. MATERIALS AND METHODS The current study retrospectively evaluated patients'records from case files and also called them for clinical and radiological followup. 96 hips with AVN of the femoral head treated with BHA were included in the study. All patients were males with a mean age of 42 years (range 30-59 years). In all cases, the acetabulum was gently reamed till it became uniformly concentric to achieve tight fitting trial cup. Clinical followup using Harris hip score (HHS) and radiological study for cup migration were done at followup. RESULTS The mean followup was 7.52 years (range 4-16 years). The HHS significantly improved from a preoperative value of 39.3 (range, 54-30) to a postoperative value of 89.12 (range 74-96). According to HHS grades, the final outcome was excellent in 52 hips, good in 28 and fair in 16 hips. Hip and groin pain was reported in four hips (5%), but did not limit activity. Subsidence (less than 5 mm) of the femoral component was seen in 8 cases. Subgroup analysis showed patients with Ficat Stage 3 having better range of motion, but similar HHS as compared to Ficat Stage 4 patients. CONCLUSION Bipolar hip arthroplasty (BHA) using tight fitting cup and acetabular reaming in AVN hip has a low incidence of groin pain, acetabular erosion and revision in midterm followup. Good outcome and mid term survival can be achieved irrespective of the Ficat Stage.
Collapse
Affiliation(s)
- Baldev Dudani
- Department of Orthopaedic, Ruby Hall Clinic, Thane, Maharashtra, India
| | - Ashok K Shyam
- Department of Academic Research, Sancheti Institute of Orthopaedic and Rehabilitation, Thane, Maharashtra, India,Department of Orthopaedic, Indian Orthopaedic Research Group, Thane, Maharashtra, India,Address for correspondence: Dr. Ashok K Shyam, Department of Academic Research, Sancheti Institute of Orthopaedic and Rehabilitation, 16, Shivaji Nagar, Pune, Maharashtra, India. E-mail:
| | - Pankush Arora
- Department of Academic Research, Sancheti Institute of Orthopaedic and Rehabilitation, Thane, Maharashtra, India,Department of Orthopaedic, Indian Orthopaedic Research Group, Thane, Maharashtra, India
| | - Arjun Veigus
- Department of Orthopaedic, Inlaks and Budhrani Hospital, Pune, Maharashtra, India
| |
Collapse
|
37
|
Treatment of failures related to articulation material in THA. A comprehensive algorithm of surgical options and open questions. Hip Int 2014; 24 Suppl 10:S48-57. [PMID: 24970035 DOI: 10.5301/hipint.5000170] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/18/2014] [Indexed: 02/04/2023]
Abstract
Total hip arthroplasty is considered one of the greatest advances in health care of the last century. More than one million THAs are estimated to be performed annually and an increasing number of revisions are expected in the future. Osteolysis and loosening are still the main reasons for failure, justifying the use of low-wear bearings.The aim of this paper is to describe the mode of failure of the different couplings (polyethylene, cross-linked PE, metal, ceramic) and the options of treatment considering the various scenarios that the surgeon has to face nowadays in the case of failure related to articulation material. A comprehensive algorithm of treatment strategies is proposed based on the best current evidence and on the authors' experience.Periodical follow-up, indications for early revision, selection of proper surgical techniques and tribology are suggested. Nowadays, few rules are strongly recommended: trying to avoid any metal in case of failure of metal-on-metal; to avoid metal in fracture of ceramic; never to mix metals or ceramics from different manufactures. We aim to address a great number of open questions. There is still need for further research and evidences in this essential field of orthopaedic surgery.
Collapse
|
38
|
Lübbeke A, Gonzalez A, Garavaglia G, Roussos C, Bonvin A, Stern R, Peter R, Hoffmeyer P. A comparative assessment of small-head metal-on-metal and ceramic-on-polyethylene total hip replacement. Bone Joint J 2014; 96-B:868-75. [PMID: 24986938 DOI: 10.1302/0301-620x.96b7.32369] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Large-head metal-on-metal (MoM) total hip replacements (THR) have given rise to concern. Comparative studies of small-head MoM THRs over a longer follow-up period are lacking. Our objective was to compare the incidence of complications such as infection, dislocation, revision, adverse local tissue reactions, mortality and radiological and clinical outcomes in small-head (28 mm) MoM and ceramic-on-polyethylene (CoP) THRs up to 12 years post-operatively. A prospective cohort study included 3341 THRs in 2714 patients. The mean age was 69.1 years (range 24 to 98) and 1848 (55.3%) were performed in women, with a mean follow-up of 115 months (18 to 201). There were 883 MoM and 2458 CoP bearings. Crude incidence rates (cases/1000 person-years) were: infection 1.3 vs 0.8; dislocation 3.3 vs 3.1 and all-cause revision 4.3 vs 2.2, respectively. There was a significantly higher revision rate after ten years (adjusted hazard ratio 9.4; 95% CI 2.6 to 33.6) in the MoM group, and ten of 26 patients presented with an adverse local tissue reaction at revision. No differences in mortality, osteolysis or clinical outcome were seen. In conclusion, we found similar results for small-head MoM and CoP bearings up to ten years post-operatively, but after ten years MoM THRs had a higher risk of all-cause revision. Furthermore, the presence of an adverse response to metal debris seen in the small-head MOM group at revision is a cause for concern.
Collapse
Affiliation(s)
- A Lübbeke
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - A Gonzalez
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - G Garavaglia
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - C Roussos
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - A Bonvin
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - R Stern
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - R Peter
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| | - P Hoffmeyer
- Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, Geneva, CH-1211, Switzerland
| |
Collapse
|
39
|
Langton DJ, Sidaginamale RP, Holland JP, Deehan D, Joyce TJ, Nargol AVF, Meek RD, Lord JK. Practical considerations for volumetric wear analysis of explanted hip arthroplasties. Bone Joint Res 2014; 3:60-8. [PMID: 24627327 PMCID: PMC4182907 DOI: 10.1302/2046-3758.33.2000249] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES Wear debris released from bearing surfaces has been shown to provoke negative immune responses in the recipient. Excessive wear has been linked to early failure of prostheses. Analysis using coordinate measuring machines (CMMs) can provide estimates of total volumetric material loss of explanted prostheses and can help to understand device failure. The accuracy of volumetric testing has been debated, with some investigators stating that only protocols involving hundreds of thousands of measurement points are sufficient. We looked to examine this assumption and to apply the findings to the clinical arena. METHODS We examined the effects on the calculated material loss from a ceramic femoral head when different CMM scanning parameters were used. Calculated wear volumes were compared with gold standard gravimetric tests in a blinded study. RESULTS Various scanning parameters including point pitch, maximum point to point distance, the number of scanning contours or the total number of points had no clinically relevant effect on volumetric wear calculations. Gravimetric testing showed that material loss can be calculated to provide clinically relevant degrees of accuracy. CONCLUSIONS Prosthetic surfaces can be analysed accurately and rapidly with currently available technologies. Given these results, we believe that routine analysis of explanted hip components would be a feasible and logical extension to National Joint Registries. Cite this article: Bone Joint Res 2014;3:60-8.
Collapse
Affiliation(s)
- D J Langton
- North Tees Explant Centre (NTEC), FarndaleHouse, University Hospital of North Tees, TS19 8PE, UK
| | | | | | | | | | | | | | | |
Collapse
|
40
|
Abstract
We reviewed the literature on the currently available choices of bearing surface in total hip replacement (THR). We present a detailed description of the properties of articulating surfaces review the understanding of the advantages and disadvantages of existing bearing couples. Recent technological developments in the field of polyethylene and ceramics have altered the risk of fracture and the rate of wear, although the use of metal-on-metal bearings has largely fallen out of favour, owing to concerns about reactions to metal debris. As expected, all bearing surface combinations have advantages and disadvantages. A patient-based approach is recommended, balancing the risks of different options against an individual’s functional demands. Cite this article: Bone Joint J 2014;96-B:147–56.
Collapse
Affiliation(s)
- A. Rajpura
- Wrightington Hospital, The Centre
for Hip Surgery, Appley Bridge, Wigan
WN6 9EP, UK
| | - D. Kendoff
- Helios ENDO Klinik, Holstenstr. 2, 22767
Hamburg, Germany
| | - T. N. Board
- Wrightington Hospital, The Centre
for Hip Surgery, Appley Bridge, Wigan
WN6 9EP, UK
| |
Collapse
|
41
|
Abstract
Total hip arthroplasty continues to be one of the most effective surgical procedures currently available. The longevity of this otherwise very successful procedure is compromised by the wear of the bearing surface. In recent years, great advances have been made in the design of bearing surfaces that poise to offer extended performance to these artificial joints. The purpose of this review is to discuss the recent technologic advances in bearing surfaces and offer an insight to the potential benefits and concerns with the alternative bearing surfaces.
Collapse
Affiliation(s)
- Richard Tuli
- Rothman Institute at Thomas Jefferson University, Philadelphia, PA 19107, USA
| | | |
Collapse
|
42
|
Abstract
Total hip arthroplasty is an effective treatment option for advanced hip arthritis in elderly patients. Studies in young patients have traditionally shown less durable results. With current implants, surgical technique, and cementless fixation methods, the durability of total hip arthroplasty may now be related to the wear performance of the bearing surfaces. To improve implant longevity, there are several bearing surface choices currently available for this demanding group of patients. Alternatives must be evaluated in terms of the risks and benefits associated with each articulation, and all new technologies must be carefully monitored over the long term.
Collapse
|
43
|
Sanders AP, Brannon RM. A simple surrogate test method to rank the wear performance of prospective ceramic materials under hip prosthesis edge-loading conditions. J Biomed Mater Res B Appl Biomater 2013; 102:311-21. [DOI: 10.1002/jbm.b.33009] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2013] [Revised: 06/01/2013] [Accepted: 07/15/2013] [Indexed: 11/11/2022]
Affiliation(s)
- Anthony P. Sanders
- Department of Mechanical Engineering; University of Utah; Salt Lake City Utah 84112
- Ortho Development Corp.; 12187 S. Business Park Dr. Draper Utah 84020
| | - Rebecca M. Brannon
- Department of Mechanical Engineering; University of Utah; Salt Lake City Utah 84112
| |
Collapse
|
44
|
Al-Hajjar M, Jennings LM, Begand S, Oberbach T, Delfosse D, Fisher J. Wear of novel ceramic-on-ceramic bearings under adverse and clinically relevant hip simulator conditions. J Biomed Mater Res B Appl Biomater 2013; 101:1456-62. [PMID: 23744622 DOI: 10.1002/jbm.b.32965] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2012] [Revised: 01/16/2013] [Accepted: 03/06/2013] [Indexed: 11/10/2022]
Abstract
Further development of ceramic materials for total hip replacement aim to increase fracture toughness and further reduce the incidence of bearing fracture. Edge loading due to translational mal positioning (microseparation) has replicated stripe wear, wear rates, and bimodal wear debris observed on retrievals. This method has replicated the fracture of early zirconia ceramic-on-ceramic bearings. This has shown the necessity of introducing microseparation conditions to the gait cycle when assessing the tribological performance of new hip replacement bearings. Two novel ceramic matrix composite materials, zirconia-toughened alumina (ZTA) and alumina-toughened zirconia (ATZ), were developed by Mathys Orthopädie GmbH. In this study, ATZ-on-ATZ and ZTA-on-ZTA bearing combinations were tested and compared with alumina-on-alumina (Al2O3-on-Al2O3) bearings under adverse microseparation and edge loading conditions using the Leeds II physiological anatomical hip joint simulator. The wear rate (±95% confidence limit) of ZTA-on-ZTA was 0.14 ± 0.10 mm(3)/million cycles and that of ATZ-on-ATZ was 0.06 ± 0.004 mm(3)/million cycles compared with a wear rate of 0.74 ± 1.73 mm(3)/million cycles for Al2O3-on-Al2O3 bearings. Stripe wear was evident on all bearing combinations; however, the stripe formed on the ATZ and ZTA femoral heads was thinner and shallower that that formed on the Al2O3 heads. Posttest phase composition measurements for both ATZ and ZTA materials showed no significant change in the monoclinic zirconia content. ATZ-on-ATZ and ZTA-on-ZTA showed superior wear resistance properties when compared with Al2O3-on-Al2O3 under adverse edge loading conditions.
Collapse
Affiliation(s)
- Mazen Al-Hajjar
- Institute of Medical and Biological Engineering, School of Mechanical Engineering University of Leeds, Leeds, UK
| | | | | | | | | | | |
Collapse
|
45
|
Scholes SC, Joyce TJ. In vitro tests of substitute lubricants for wear testing orthopaedic biomaterials. Proc Inst Mech Eng H 2013; 227:693-703. [PMID: 23636752 DOI: 10.1177/0954411913481549] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Bovine serum is the lubricant recommended by several international standards for the wear testing of orthopaedic biomaterials; however, there are issues over its use due to batch variation, degradation, cost and safety. For these reasons, alternative lubricants were investigated. A 50-station Super-CTPOD (circularly translating pin-on-disc) wear test rig was used, which applied multidirectional motion to ultra-high-molecular-weight polyethylene test pins rubbing against cobalt chromium discs. Thirteen possible alternative lubricants were tested. The use of soy protein as a lubricant gave statistically higher wear, while soya oil, olive oil, Channel Island milk, whole milk, whey, wheatgerm oil, 11 mg/mL egg white, albumin/globulin mix and albumin/globulin/chondroitin sulphate mix all gave statistically lower wear than bovine serum. The lubricants giving the closest wear results to bovine serum were 20 and 40 mg/mL egg white solutions. A light absorbance assay found that these egg white solutions suffered from a high degradation rate that increased with increasing protein content. While egg white solutions offer the best alternative lubricant to bovine serum due to the wear volumes produced, cost-effectiveness and safety of handling, protein degradation will still occur, leading to the need for regular lubricant replacement. Of the lubricants tested in this study, none were found to be superior to bovine serum.
Collapse
Affiliation(s)
- Susan C Scholes
- School of Mechanical and Systems Engineering, Newcastle University, Newcastle upon Tyne, UK
| | | |
Collapse
|
46
|
Abstract
Metal-on-metal prostheses are increasingly and widely used in total hip arthroplasty, and offer particular benefit to patients with osteoarthritis. Adverse effects related to the release of metal ions (such as cytotoxicity, genotoxicity, carcinogenicity and metal allergy) are common, however. The aims of this review article were to explore the relationship between corrosion products and implant-related hypersensitivity, define normal and toxic metal ion concentrations, and differentiate between allergy and infection in painful total hip replacement. The simultaneous presence of corrosion products and hypersensitivity-related tissue reactions indicates a relationship between the development of corrosion and implant-related hypersensitivity. There are no clear boundaries between normal and toxic metal ion concentrations. Several methods exist for the differential diagnosis of metal allergy and infection, including ultrasound-guided aspiration, patch testing and arthroscopic biopsy. More research is required to elucidate fully the relationship between metal articulations and allergy, and to determine the concentrations of metal ions that lead to harmful effects.
Collapse
Affiliation(s)
- Yirong Zeng
- Third Department of Orthopaedics, First Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou, Guangdong Province, China.
| | | |
Collapse
|
47
|
Al-Hajjar M, Fisher J, Tipper JL, Williams S, Jennings LM. Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions. Proc Inst Mech Eng H 2013; 227:535-42. [DOI: 10.1177/0954411912474613] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Ceramic-on-ceramic bearings have become of great interest due to the substantial improvements in the manufacturing techniques and material properties and due to polyethylene wear debris–induced osteolysis and the issues with metal wear debris and ion release by metal-on-metal bearings. Edge loading conditions due to translational malpositioning (microseparation conditions) have been shown to replicate clinically relevant wear mechanisms and increase the wear of ceramic-on-ceramic bearings; thus, it was necessary to test new bearing materials and designs under these adverse conditions. The aim of this study was to assess the effect of increasing head size on the wear of BIOLOX® delta ceramic-on-ceramic bearings under edge loading conditions due to rotational (steep cup inclination angle) and translational (microseparation) malpositioning. In this study, six 36-mm ceramic-on-ceramic bearings (BIOLOX delta, CeramTec, Germany) were tested under standard and edge loading conditions using the Leeds II hip simulator and compared to the 28-mm bearings tested and published previously under identical conditions. The mean wear rate under standard gait conditions was below 0.1 mm3/million cycles for both the 28-mm and the 36-mm ceramic-on-ceramic bearings, and increasing the inclination angle did not affect the wear rates. The introduction of microseparation to the gait cycle increased the wear rate of ceramic-on-ceramic bearing and resulted in stripe wear on the femoral heads. Under microseparation conditions, the wear rate of size 36-mm bearings (0.22 mm3/million cycles) was significantly higher ( p = 0.004) than that for size 28-mm bearings (0.13 mm3/million cycles). This was due to the larger contact area for the larger bearings and deprived lubrication under edge loading conditions. The wear rate of BIOLOX delta ceramic-on-ceramic bearings under microseparation conditions was still very low ( <0.25 mm3/million cycles) compared to earlier generation ceramic-on-ceramic bearings (BIOLOX forte, 1.84 mm3/million cycles) and other bearing materials such as metal-on-metal bearings (2–8 mm3/million cycles).
Collapse
Affiliation(s)
- Mazen Al-Hajjar
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - John Fisher
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
- Leeds Musculoskeletal Biomedical Research Unit, The Leeds Teaching Hospital NHS Trust, University of Leeds, Leeds, UK
| | - Joanne L Tipper
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
- Leeds Musculoskeletal Biomedical Research Unit, The Leeds Teaching Hospital NHS Trust, University of Leeds, Leeds, UK
| | - Sophie Williams
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Louise M Jennings
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
48
|
Hallab NJ, Jacobs JJ. Orthopedic Applications. Biomater Sci 2013. [DOI: 10.1016/b978-0-08-087780-8.00073-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
49
|
Voleti PB, Baldwin KD, Lee GC. Metal-on-metal vs conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials. J Arthroplasty 2012; 27:1844-9. [PMID: 22771090 DOI: 10.1016/j.arth.2012.05.023] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2012] [Accepted: 05/23/2012] [Indexed: 02/01/2023] Open
Abstract
Metal-on-metal (MOM) hip articulations represent a potential alternative to conventional metal-on-polyethylene total hip arthroplasty (THA). We performed a systematic review of the peer-reviewed literature in search of studies comparing MOM with conventional primary THA with regard to functional outcomes, radiographic outcomes, and complication rates. Four Level I randomized controlled trials remained following our screening process. The data published in these studies were extracted and aggregated using a Mantel-Haenszel cumulative fixed effects meta-analysis. We found no significant difference between MOM and conventional THA with regard to functional outcomes as measured by Harris hip scores and radiographic outcomes as measured by radiolucent lines. Patients with MOM THA did however demonstrate a 3.37 times greater complication rate (1.57, 7.26). In light of the lack of superiority, the increased complication rate, the greater cost, and the potential for adverse medical consequences associated with MOM THA, these bearing surfaces should be used with caution.
Collapse
Affiliation(s)
- Pramod B Voleti
- Department of Orthopaedic Surgery, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, USA
| | | | | |
Collapse
|
50
|
Meyer H, Mueller T, Goldau G, Chamaon K, Ruetschi M, Lohmann CH. Corrosion at the cone/taper interface leads to failure of large-diameter metal-on-metal total hip arthroplasties. Clin Orthop Relat Res 2012; 470:3101-8. [PMID: 22864616 PMCID: PMC3462871 DOI: 10.1007/s11999-012-2502-5] [Citation(s) in RCA: 104] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Metal-on-metal (MoM) THAs have reduced wear rates compared with metal-on-polyethylene. However, elevated serum metal ion levels and pseudotumors have been reported in large MoM articulations. QUESTIONS/PURPOSES We therefore determined (1) if corrosion occurred at the cone/taper interface leading to instability in patients with large-diameter THAs; (2) how patients presented clinically and radiographically; (3) if adverse periprosthetic tissue reactions occurred; (4) whether metal was released from the implants into the periprosthetic tissues; and (5) if head size correlated with metal release. METHODS We reviewed 114 patients who had revisions of large-diameter head MoM articulations. Mean time of implantation was 46 months. To identify adverse reactions and particle load, tissues were stained by hematoxylin and eosin and CD3/CD20/CD68 antibodies. Periprosthetic tissues were analyzed for metal content and distribution in different regions. Electrochemical reactions between the stem and adapter were investigated by a minicell electrode. RESULTS Electrochemical studies on the stem and the head adapter showed a risk for galvanic corrosion. Ninety-four percent of patients had instability at the cone/taper interface. All patients presented with early clinical symptoms; 59 patients had radiographic signs of loosening. One hundred four patients had foreign body reactions and necrosis. The largest amounts of metal released were titanium or iron. We found no correlation between head size and metal ion release. CONCLUSIONS These findings suggest that in modular cone/taper connections, friction of the MoM articulations may cause failure of the cone/taper interface leading to galvanic corrosion and loosening. It is unclear whether the design of this MoM system provides sufficient stability at the taper.
Collapse
Affiliation(s)
- Heiko Meyer
- Department of Orthopaedics, Otto-von-Guericke University, Leipziger Str 44, 39108 Magdeburg, Germany
| | - Tina Mueller
- Department of Orthopaedics, Otto-von-Guericke University, Leipziger Str 44, 39108 Magdeburg, Germany
| | - Gesine Goldau
- University of Applied Sciences, Magdeburg-Stendal, Germany
| | - Kathrin Chamaon
- Department of Orthopaedics, Otto-von-Guericke University, Leipziger Str 44, 39108 Magdeburg, Germany
| | - Marcel Ruetschi
- Department of Orthopaedics, Loretto Hospital, Freiburg, Germany
| | - Christoph H. Lohmann
- Department of Orthopaedics, Otto-von-Guericke University, Leipziger Str 44, 39108 Magdeburg, Germany
| |
Collapse
|