• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4614809)   Today's Articles (340)   Subscriber (49391)
For: Lin ZM, Meakins S, Morlock MM, Parsons P, Hardaker C, Flett M, Isaac G. Deformation of press-fitted metallic resurfacing cups. Part 1: Experimental simulation. Proc Inst Mech Eng H 2006;220:299-309. [PMID: 16669396 DOI: 10.1243/095441105x69150] [Citation(s) in RCA: 86] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Number Cited by Other Article(s)
1
Niki Y, Huber G, Behzadi K, Morlock MM. Vibratory insertion of press-fit acetabular components requires less force than a single blow technique. Bone Joint Res 2024;13:272-278. [PMID: 38834190 DOI: 10.1302/2046-3758.136.bjr-2023-0263.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/06/2024]  Open
2
Yoshida K, Fukushima K, Sakai R, Uchiyama K, Takahira N, Ujihira M. A novel primary stability test method for artificial acetabular shells considering vertical load during level walking and shell position. PLoS One 2024;19:e0296919. [PMID: 38421998 PMCID: PMC10903903 DOI: 10.1371/journal.pone.0296919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 12/22/2023] [Indexed: 03/02/2024]  Open
3
Ruhr M, Huber G, Niki Y, Lohner L, Ondruschka B, Morlock MM. Impaction procedure influences primary stability of acetabular press-fit components. Bone Joint J 2023;105-B:261-268. [PMID: 36854327 DOI: 10.1302/0301-620x.105b3.bjj-2022-1011.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2023]
4
Ruhr M, Baetz J, Pueschel K, Morlock MM. Influence of acetabular cup thickness on seating and primary stability in total hip arthroplasty. J Orthop Res 2022;40:2139-2146. [PMID: 34855229 DOI: 10.1002/jor.25232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/05/2021] [Accepted: 11/20/2021] [Indexed: 02/04/2023]
5
Yoshida K, Fukushima K, Sakai R, Uchiyama K, Takahira N, Ujihira M. Influence of outer geometry on primary stability for uncemented acetabular shells in developmental dysplasia of the hip. Proc Inst Mech Eng H 2020;235:65-72. [PMID: 32996400 DOI: 10.1177/0954411920960000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
6
Comparison of Test Setups for the Experimental Evaluation of the Primary Fixation Stability of Acetabular Cups. MATERIALS 2020;13:ma13183982. [PMID: 32916802 PMCID: PMC7559462 DOI: 10.3390/ma13183982] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/28/2020] [Accepted: 09/03/2020] [Indexed: 11/22/2022]
7
Doyle R, van Arkel RJ, Muirhead-Allwood S, Jeffers JRT. Impaction technique influences implant stability in low-density bone model. Bone Joint Res 2020;9:386-393. [PMID: 32793333 PMCID: PMC7393184 DOI: 10.1302/2046-3758.97.bjr-2019-0303.r1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
8
Time-dependent Viscoelastic Response of Acetabular Bone and Implant Seating during Dynamic Implantation of Press-fit Cups. Med Eng Phys 2020;81:68-76. [PMID: 32507677 DOI: 10.1016/j.medengphy.2020.05.012] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2019] [Revised: 04/04/2020] [Accepted: 05/13/2020] [Indexed: 11/24/2022]
9
Fixation Stability of Uncemented Acetabular Cups With Respect to Different Bone Defect Sizes. J Arthroplasty 2020;35:1720-1728. [PMID: 32063411 DOI: 10.1016/j.arth.2020.01.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 12/23/2019] [Accepted: 01/09/2020] [Indexed: 02/01/2023]  Open
10
Al-Saffar AA, Evans SL. Effect of gap outside contact area on lubrication of metal-on-Metal total hip replacement. Comput Methods Biomech Biomed Engin 2020;23:675-689. [PMID: 32396392 DOI: 10.1080/10255842.2020.1758679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
11
Influence of the Acetabular Cup Material on the Shell Deformation and Strain Distribution in the Adjacent Bone-A Finite Element Analysis. MATERIALS 2020;13:ma13061372. [PMID: 32197478 PMCID: PMC7142599 DOI: 10.3390/ma13061372] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/16/2020] [Revised: 03/06/2020] [Accepted: 03/13/2020] [Indexed: 12/22/2022]
12
Beckmann NA, Bitsch RG, Bormann T, Braun S, Jaeger S. Titanium Acetabular Component Deformation under Cyclic Loading. MATERIALS 2019;13:ma13010052. [PMID: 31861893 PMCID: PMC6981461 DOI: 10.3390/ma13010052] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2019] [Revised: 12/15/2019] [Accepted: 12/17/2019] [Indexed: 12/30/2022]
13
Doyle R, van Arkel RJ, Jeffers JRT. Effect of impaction energy on dynamic bone strains, fixation strength, and seating of cementless acetabular cups. J Orthop Res 2019;37:2367-2375. [PMID: 31317554 PMCID: PMC6851739 DOI: 10.1002/jor.24418] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Accepted: 07/02/2019] [Indexed: 02/04/2023]
14
Farrier AJ, Moore L, Manning W, Avila C, Collins SN, Holland J. Comparison study of temperature and deformation changes in the femoral component of a novel ceramic-on-ceramic hip resurfacing bearing to a metal standard, using a cadaveric model. Proc Inst Mech Eng H 2019;233:1318-1326. [PMID: 31608770 DOI: 10.1177/0954411919881520] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
15
Messer-Hannemann P, Campbell GM, Morlock MM. Deformation of acetabular press-fit cups: Influence of design and surgical factors. Clin Biomech (Bristol, Avon) 2019;69:96-103. [PMID: 31325804 DOI: 10.1016/j.clinbiomech.2019.07.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2019] [Revised: 07/11/2019] [Accepted: 07/11/2019] [Indexed: 02/07/2023]
16
Farrier AJ, Moore L, Manning W, Avila C, Collins SN, Holland J. Comparing the cup deformation following implantation of a novel ceramic-on-ceramic hip resurfacing bearing to a metal standard in a cadaveric model. Proc Inst Mech Eng H 2019;233:603-610. [PMID: 31017527 DOI: 10.1177/0954411919845721] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
17
Jahnke A, Bott CC, Fonseca Ulloa CA, Jahnke GW, Rickert M, Ishaque BA, Ahmed GA. In vitro examination of the primary stability of three press-fit acetabular cups under consideration of two different bearing couples. Med Eng Phys 2019;67:49-54. [PMID: 30902521 DOI: 10.1016/j.medengphy.2019.03.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 01/09/2019] [Accepted: 03/10/2019] [Indexed: 12/21/2022]
18
Chan MK, Caudwell M, Suchowersky A, Ashton A. Femoral side-only revision options for the Birmingham resurfacing arthroplasty. ANZ J Surg 2019;89:1016-1021. [PMID: 30873748 DOI: 10.1111/ans.15036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2018] [Revised: 11/05/2018] [Accepted: 11/13/2018] [Indexed: 11/28/2022]
19
An in vitro model of impaction during hip arthroplasty. J Biomech 2019;82:220-227. [DOI: 10.1016/j.jbiomech.2018.10.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 10/23/2018] [Accepted: 10/23/2018] [Indexed: 11/16/2022]
20
Acetabular Debonding: An Investigation of Porous Coating Delamination in Hip Resurfacing Arthroplasty. Adv Orthop 2018;2018:5282167. [PMID: 30515334 PMCID: PMC6236702 DOI: 10.1155/2018/5282167] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Accepted: 10/01/2018] [Indexed: 11/21/2022]  Open
21
Schulze C, Vogel D, Sander M, Bader R. Calibration of crushable foam plasticity models for synthetic bone material for use in finite element analysis of acetabular cup deformation and primary stability. Comput Methods Biomech Biomed Engin 2018;22:25-37. [PMID: 30449160 DOI: 10.1080/10255842.2018.1524884] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
22
Jahnke A, Schroeder S, Fonseca Ulloa CA, Ahmed GA, Ishaque BA, Rickert M. Effect of bearing friction torques on the primary stability of press-fit acetabular cups: A novel in vitro method. J Orthop Res 2018;36:2745-2753. [PMID: 29744927 DOI: 10.1002/jor.24041] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 04/27/2018] [Indexed: 02/04/2023]
23
Vogel D, Schulze C, Dempwolf H, Kluess D, Bader R. Biomechanical behavior of modular acetabular cups made of poly-ether-ether-ketone: A finite element study. Proc Inst Mech Eng H 2018;232:1030-1038. [DOI: 10.1177/0954411918797600] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
24
Manning WA, Pandorf T, Deehan DJ, Holland J. Early shape change behaviour of an uncemented contemporary hip cup: A cadaveric experiment replicating host bone behaviour through temperature control. Proc Inst Mech Eng H 2018;232:843-849. [DOI: 10.1177/0954411918790776] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
25
Yoshimoto K, Nakashima Y, Wakiyama M, Hara D, Nakamura A, Iwamoto M. Initial stability of a highly porous titanium cup in an acetabular bone defect model. J Orthop Sci 2018;23:665-670. [PMID: 29657105 DOI: 10.1016/j.jos.2018.03.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 03/15/2018] [Accepted: 03/25/2018] [Indexed: 11/27/2022]
26
van Ladesteijn R, Leslie H, Manning WA, Holland JP, Deehan DJ, Pandorf T, Aspden RM. Mechanical properties of cancellous bone from the acetabulum in relation to acetabular shell fixation and compared with the corresponding femoral head. Med Eng Phys 2018;53:75-81. [DOI: 10.1016/j.medengphy.2018.01.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 01/10/2018] [Accepted: 01/15/2018] [Indexed: 10/18/2022]
27
Nguyen VH, Rosi G, Naili S, Michel A, Raffa ML, Bosc R, Meningaud JP, Chappard C, Takano N, Haiat G. Influence of anisotropic bone properties on the biomechanical behavior of the acetabular cup implant: a multiscale finite element study. Comput Methods Biomech Biomed Engin 2017;20:1312-1325. [PMID: 28768422 DOI: 10.1080/10255842.2017.1357703] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
28
Alshuhri AA, Holsgrove TP, Miles AW, Cunningham JL. Non-invasive vibrometry-based diagnostic detection of acetabular cup loosening in total hip replacement (THR). Med Eng Phys 2017;48:188-195. [PMID: 28709931 DOI: 10.1016/j.medengphy.2017.06.037] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2016] [Revised: 06/19/2017] [Accepted: 06/21/2017] [Indexed: 10/19/2022]
29
Small SR, Meding JB, Oja JW, Lakstins KS, Gehron DJ, Rogge RD, Buckley CA. Shell design and reaming technique affect deformation in mobile-bearing total hip arthroplasty acetabular components. Proc Inst Mech Eng H 2017;231:691-698. [DOI: 10.1177/0954411917701952] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
30
Panjeton GD, Kim SE, Chang K, Palm LS, Ifju PG. Deformation of the Zurich cementless acetabular cup caused by implantation in a canine cadaver model. Vet Surg 2017;46:441-447. [PMID: 28198543 DOI: 10.1111/vsu.12629] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Accepted: 11/16/2016] [Indexed: 11/28/2022]
31
Michel A, Nguyen VH, Bosc R, Vayron R, Hernigou P, Naili S, Haiat G. Finite element model of the impaction of a press-fitted acetabular cup. Med Biol Eng Comput 2016;55:781-791. [PMID: 27491803 DOI: 10.1007/s11517-016-1545-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Accepted: 07/03/2016] [Indexed: 01/07/2023]
32
Crosnier EA, Keogh PS, Miles AW. The effect of dynamic hip motion on the micromotion of press-fit acetabular cups in six degrees of freedom. Med Eng Phys 2016;38:717-24. [DOI: 10.1016/j.medengphy.2016.04.014] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Revised: 03/30/2016] [Accepted: 04/15/2016] [Indexed: 11/29/2022]
33
Medley JB. Can physical joint simulators be used to anticipate clinical wear problems of new joint replacement implants prior to market release? Proc Inst Mech Eng H 2016;230:347-58. [PMID: 27160555 DOI: 10.1177/0954411916643902] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2016] [Accepted: 03/18/2016] [Indexed: 11/16/2022]
34
Dold P, Pandorf T, Flohr M, Preuss R, Bone MC, Joyce TJ, Holland J, Deehan D. Acetabular shell deformation as a function of shell stiffness and bone strength. Proc Inst Mech Eng H 2016;230:259-64. [PMID: 26888887 DOI: 10.1177/0954411916632792] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2015] [Accepted: 12/21/2015] [Indexed: 11/16/2022]
35
Qiu C, Wang L, Li D, Jin Z. The influence of metallic shell deformation on the contact mechanics of a ceramic-on-ceramic total hip arthroplasty. Proc Inst Mech Eng H 2015;230:4-12. [PMID: 26511269 DOI: 10.1177/0954411915614514] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2015] [Accepted: 09/14/2015] [Indexed: 11/17/2022]
36
In-vivo degradation of middle-term highly cross-linked and remelted polyethylene cups: Modification induced by creep, wear and oxidation. J Mech Behav Biomed Mater 2015. [PMID: 26202469 DOI: 10.1016/j.jmbbm.2015.06.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
37
Bone MC, Dold P, Flohr M, Preuss R, Joyce TJ, Aspden RM, Holland J, Deehan D. The influence of the strength of bone on the deformation of acetabular shells: a laboratory experiment in cadavers. Bone Joint J 2015;97-B:473-7. [PMID: 25820884 DOI: 10.1302/0301-620x.97b4.35017] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
38
Crosnier EA, Keogh PS, Miles AW. A novel method to assess primary stability of press-fit acetabular cups. Proc Inst Mech Eng H 2014;228:1126-34. [DOI: 10.1177/0954411914557714] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
39
Dold P, Bone MC, Flohr M, Preuss R, Joyce TJ, Deehan D, Holland J. Validation of an optical system to measure acetabular shell deformation in cadavers. Proc Inst Mech Eng H 2014;228:781-6. [DOI: 10.1177/0954411914546562] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
40
Cadossi M, Tedesco G, Savarino L, Baldini N, Mazzotti A, Greco M, Giannini S. Effect of acetabular cup design on metal ion release in two designs of metal-on-metal hip resurfacing. J Biomed Mater Res B Appl Biomater 2014;102:1595-601. [DOI: 10.1002/jbm.b.33191] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2013] [Revised: 02/14/2014] [Accepted: 04/12/2014] [Indexed: 11/08/2022]
41
Dickinson AS, Browne M, Roques AC, Taylor AC. A fatigue assessment technique for modular and pre-stressed orthopaedic implants. Med Eng Phys 2013;36:72-80. [PMID: 24148237 DOI: 10.1016/j.medengphy.2013.09.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2013] [Revised: 08/09/2013] [Accepted: 09/18/2013] [Indexed: 11/27/2022]
42
Bone MC, Dold P, Flohr M, Preuss R, Joyce TJ, Deehan D, Holland J. A novel method for measuring acetabular cup deformation in cadavers. Proc Inst Mech Eng H 2013;227:1341-4. [PMID: 24150842 DOI: 10.1177/0954411913507706] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
43
Nakahara I, Takao M, Bandoh S, Bertollo N, Walsh WR, Sugano N. In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model. J Orthop Res 2013;31:485-92. [PMID: 23097319 DOI: 10.1002/jor.22251] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2012] [Accepted: 09/24/2012] [Indexed: 02/04/2023]
44
Small SR, Berend ME, Howard LA, Rogge RD, Buckley CA, Ritter MA. High initial stability in porous titanium acetabular cups: a biomechanical study. J Arthroplasty 2013;28:510-6. [PMID: 23142455 DOI: 10.1016/j.arth.2012.07.035] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2011] [Revised: 06/08/2012] [Accepted: 07/27/2012] [Indexed: 02/06/2023]  Open
45
Meding JB, Small SR, Jones ME, Berend ME, Ritter MA. Acetabular cup design influences deformational response in total hip arthroplasty. Clin Orthop Relat Res 2013;471:403-9. [PMID: 22948528 PMCID: PMC3549190 DOI: 10.1007/s11999-012-2553-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
46
Hothi HS, Busfield JJ, Shelton JC. Deformation of uncemented metal acetabular cups following impaction: experimental and finite element study. Comput Methods Biomech Biomed Engin 2012;17:1261-74. [DOI: 10.1080/10255842.2012.744397] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
47
Liu F, Chen Z, Gu Y, Wang Q, Cui W, Fan W. Deformation of the Durom acetabular component and its impact on tribology in a cadaveric model--a simulator study. PLoS One 2012;7:e45786. [PMID: 23144694 PMCID: PMC3483233 DOI: 10.1371/journal.pone.0045786] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2012] [Accepted: 08/22/2012] [Indexed: 12/12/2022]  Open
48
Gross TP, Liu F. Hip resurfacing with the Biomet Hybrid ReCap-Magnum system: 7-year results. J Arthroplasty 2012;27:1683-1689.e2. [PMID: 22595183 DOI: 10.1016/j.arth.2012.03.049] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2011] [Accepted: 03/28/2012] [Indexed: 02/01/2023]  Open
49
The effect of cup orientation and coverage on contact mechanics and range of motion of metal-on-metal hip resurfacing arthroplasty. Proc Inst Mech Eng H 2012. [DOI: 10.1177/0954411912456926] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
50
Souffrant R, Zietz C, Fritsche A, Kluess D, Mittelmeier W, Bader R. Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability. Comput Methods Biomech Biomed Engin 2012;15:787-93. [DOI: 10.1080/10255842.2011.561012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
PrevPage 1 of 2 12Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA