1
|
Yu Q, Zou ZL, Lu HG, Pan XK, Hu XQ, Shen ZH. Finite element analysis of biomechanical investigation on diverse internal fixation techniques in oblique lumbar interbody fusion. BMC Musculoskelet Disord 2024; 25:804. [PMID: 39395967 DOI: 10.1186/s12891-024-07887-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Accepted: 09/20/2024] [Indexed: 10/14/2024] Open
Abstract
BACKGROUND To establish a three-dimensional finite element model of the lumbar spine and investigate the impact of different fixation techniques on the biomechanical characteristics of oblique lumbar interbody fusion (OLIF). METHODS The study aimed to establish and validate a comprehensive three-dimensional model of the lower lumbar spine (L3-S1) using the finite element method. L4-L5 was selected as the surgical segment, and four distinct OLIF surgical models were constructed: Stand-alone (SA), unilateral cortical bone trajectory screw (UCBT), bilateral cortical bone trajectory screw (BCBT), and bilateral pedicle screw (BPS). The models were underwent a pure moment of 10N·m to simulate lumbar extension, flexion, left bending, right bending, left and right rotation movements. Subsequently, the range of motion (ROM), cage stress, and fixation stress were calculated. RESULTS In the L3-L5 segment, the BCBT group showed the most limited range of motion (ROM) under exercise load, indicating superior stability within this group. The ROM and cage stress values were found to be highest in the SA group. In contrast, the cage and internal fixation stress in the BPS group were observed to be lowest (9.91 ~ 53.83MPa, 44.93 ~ 84.85 MPa). With the exception of right bending and right rotation, the UCBT group demonstrated higher levels of internal fixation stress (102.20 ~ 164.62 MPa). CONCLUSIONS The study found that OLIF-assisted internal fixation improved segmental stability and reduced cage stress. The BPS group had advantages over the CBT group in preventing endplate damage and reducing the risk of cage subsidence. However, BCBT group has distinct merits in maintaining surgical segment stability, distributing stress load on the spinal motor unit, and reducing the likelihood of adjacent segment degeneration (ASD).
Collapse
Affiliation(s)
- Qi Yu
- Department of Orthopaedics, Haining People's Hospital, Jiaxing, Zhejiang, 314400, China
- Department of Orthopaedics, The Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, 314001, China
| | - Zhuo Lin Zou
- Department of Infectious Diseases, The First Hospital of Jiaxing, The Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, 314001, China
| | - Hui Gen Lu
- Department of Orthopaedics, The Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, 314001, China
| | - Xue Kang Pan
- Department of Orthopaedics, The Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, 314001, China
| | - Xu Qi Hu
- Department of Orthopaedics, The Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, 314001, China
| | - Zhong Hai Shen
- Department of Orthopaedics, The Second Affiliated Hospital of Jiaxing University, Jiaxing, Zhejiang, 314001, China.
| |
Collapse
|
2
|
Li C, Zhao Y, Qi L, Xu B, Yue L, Zhu R, Li C. Comparison of biomechanical effects of polyetheretherketone (PEEK) rods and titanium rods in lumbar long-segment instrumentation: a finite element study. Front Bioeng Biotechnol 2024; 12:1416046. [PMID: 39055340 PMCID: PMC11269095 DOI: 10.3389/fbioe.2024.1416046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Accepted: 06/24/2024] [Indexed: 07/27/2024] Open
Abstract
Introduction Polyetheretherketone (PEEK) lumbar fusion rods have been successfully used in short-segment posterior instrumentation to prevent adjacent segment degeneration. However, limited studies have reported their application in lumbar long-segment instrumentation. This study aimed to compare the biomechanical performances of PEEK rods and titanium rods in lumbar long-segment instrumentation using finite element (FE) models, with the expectation of providing clinical guidance. Methods A lumbar FE model (A) and four lumbar fixation FE models (BI, CI, BII, CII) of the L1-S1 vertebral body were developed using CT image segmentation (A: intact model; BI: intact model with L2-S1 PEEK rod internal fixation; CI: intact model with L2-S1 titanium rod internal fixation; BII: intact model with L3-S1 PEEK rod internal fixation; CII: intact model with L3-S1 titanium rod internal fixation). A 150-N preload was applied to the top surface of L1, similar to the intact model. The stresses on the lumbar intervertebral disc, facet joint, pedicle screws, and rods were calculated to evaluate the biomechanical effect of the different fixation procedures in lumbar long-segment instrumented surgery. Results Under the four physiological motion states, the average stresses on the adjacent segment intervertebral disc and facet joint in all fixation models were greater than those in the intact model. Furthermore, the average stresses on the adjacent segment intervertebral disc and facet joint were greater in models CI and CII than in models BI and BII, respectively. The average stresses on the pedicle screws and rods were decreased in models BI and BII compared with models CI and CII under the four physiological motion states, respectively. Discussion The PEEK rod internal fixation system may have better biomechanical properties than the titanium rod internal fixation system in delaying adjacent segment degeneration, improving the lumbar function of postoperative patients, and reducing the risk of screw loosening and breakage in lumbar long-segment instrumentation.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Chunde Li
- Department of Orthopedics, Peking University First Hospital, Beijing, China
| |
Collapse
|
3
|
Li J, Cao S, Zhao B. Biomechanical comparison of polyetheretherketone rods and titanium alloy rods in transforaminal lumbar interbody fusion: a finite element analysis. BMC Surg 2024; 24:169. [PMID: 38811965 PMCID: PMC11134660 DOI: 10.1186/s12893-024-02462-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Accepted: 05/20/2024] [Indexed: 05/31/2024] Open
Abstract
BACKGROUND Whether polyetheretherketone (PEEK) rods have potential as an alternative to titanium alloy (Ti) rods in transforaminal lumbar interbody fusion (TLIF) remains unclear, especially in cases with insufficient anterior support due to the absence of a cage. The purpose of this study was to investigate biomechanical differences between PEEK rods and Ti rods in TLIF with and without a cage. METHODS An intact L1-L5 lumbar finite element model was constructed and validated. Accordingly, four TLIF models were developed: (1) Ti rods with a cage; (2) PEEK rods with a cage; (3) Ti rods without a cage; and (4) PEEK rods without a cage. The biomechanical properties were then compared among the four TLIF constructs. RESULTS With or without a cage, no obvious differences were found in the effect of PEEK rods and Ti rods on the range of motion, adjacent disc stress, and adjacent facet joint force. Compared to Ti rods, PEEK rods increase the average bone graft strain (270.8-6055.2 µE vs. 319.0-8751.6 µE). Moreover, PEEK rods reduced the stresses on the screw-rod system (23.1-96.0 MPa vs. 7.2-48.4 MPa) but increased the stresses on the cage (4.6-35.2 MPa vs. 5.6-40.9 MPa) and endplates (5.7-32.5 MPa vs. 6.6-37.6 MPa). CONCLUSIONS Regardless of whether a cage was used for TLIF, PEEK rods theoretically have the potential to serve as an alternative to Ti rods because they may provide certain stability, increase the bone graft strain, and reduce the posterior instrumentation stress, which might promote bony fusion and decrease instrumentation failure.
Collapse
Affiliation(s)
- Jie Li
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, 710004, Shaanxi Province, China
| | - Shuai Cao
- Department of Orthopedics, Civil Aviation General Hospital, No. 1, Gaojing Stress, Chaoyang District, Beijing, 100123, China
| | - Bo Zhao
- Department of Orthopedics, Second Affiliated Hospital of Xi'an Jiaotong University, 157th West Fifth Road, Xi'an, 710004, Shaanxi Province, China.
| |
Collapse
|
4
|
Kostenko E, Stonkus R, Šengaut J, Višniakov N, Maknickas A. Quantitative Analysis of Stress-Stretch Curves in Canine Lumbar Vertebrae Using Modified Logistic Functions. Bioengineering (Basel) 2024; 11:516. [PMID: 38790381 PMCID: PMC11117871 DOI: 10.3390/bioengineering11050516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Revised: 05/03/2024] [Accepted: 05/15/2024] [Indexed: 05/26/2024] Open
Abstract
BACKGROUND The mechanical characteristics of bone are crucial for comprehending its functionality and response to different load conditions, which are essential for advancing medical treatments, implants, and prosthetics. By employing mathematical modeling to analyze the mechanical properties of bone, we can assess stress and deformation under both normal and abnormal conditions. This analysis offers valuable perspectives on potential fracture risks, the effects of diseases, and the effectiveness of various treatments. Therefore, researchers are attempting to find an adequate mathematical description of the mechanical properties of bone. METHODS Experimental stress-stretch external loading curves were obtained through investigations of canine vertebrae. The obtained experimental curves were fitted using the SciPy Python library with a slightly modified logistic function (logistic function plus additional const). RESULTS The resulting coefficient of determination R2 (R squared) for most curves was near 0.999, indicating that an appropriate fitting function was selected for the description of the experimental stress-stretch curves. CONCLUSIONS The stress-stretch behavior of canine vertebrae can be described using a logistic function modified by adding additional parameters for the most accurate fitting results.
Collapse
Affiliation(s)
- Ernest Kostenko
- Department of Veterinary, Faculty of Agrotechnologies, Vilniaus Kolegija/Higher Education Institution, 08105 Vilnius, Lithuania
| | - Rimantas Stonkus
- Department of Mechatronics, Robotics and Digital Manufacturing, Vilnius Gediminas Technical University, 10105 Vilnius, Lithuania
| | | | - Nikolaj Višniakov
- Institute of Mechanical Science, Vilnius Gediminas Technical University, 10105 Vilnius, Lithuania
| | - Algirdas Maknickas
- Institute of Mechanical Science, Vilnius Gediminas Technical University, 10105 Vilnius, Lithuania
- Department of Biomechanical Engineering, Vilnius Gediminas Technical University, 10105 Vilnius, Lithuania
| |
Collapse
|
5
|
Zhou C, Meng X, Huang S, Chen H, Zhou H, Liao Y, Tang Z, Zhang X, Li H, Sun W, Wang Y. Biomechanical study of different bone cement distribution on osteoporotic vertebral compression Fracture-A finite element analysis. Heliyon 2024; 10:e26726. [PMID: 38434291 PMCID: PMC10907677 DOI: 10.1016/j.heliyon.2024.e26726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 02/18/2024] [Accepted: 02/19/2024] [Indexed: 03/05/2024] Open
Abstract
Purpose This study aimed to compare the biomechanical effects of different bone cement distribution methods on osteoporotic vertebral compression fractures (OVCF). Patients and methods Raw CT data from a healthy male volunteer was used to create a finite element model of the T12-L2 vertebra using finite element software. A compression fracture was simulated in the L1 vertebra, and two forms of bone cement dispersion (integration group, IG, and separation group, SG) were also simulated. Six types of loading (flexion, extension, left/right bending, and left/right rotation) were applied to the models, and the stress distribution in the vertebra and intervertebral discs was observed. Additionally, the maximum displacement of the L1 vertebra was evaluated. Results Bone cement injection significantly reduced stress following L1 vertebral fractures. In the L1 vertebral body, the maximum stress of SG was lower than that of IG during flexion, left/right bending, and left/right rotation. In the T12 vertebral body, compared with IG, the maximum stress of SG decreased during flexion and right rotation. In the L2 vertebral body, the maximum stress of SG was the lowest under all loading conditions. In the T12-L1 intervertebral disc, compared with IG, the maximum stress of SG decreased during flexion, extension, and left/right bending and was basically the same during left/right rotation. However, in the L1-L2 intervertebral discs, the maximum stress of SG increased during left/right rotation compared with that of IG. Furthermore, the maximum displacement of SG was smaller than that of IG in the L1 vertebral bodies under all loading conditions. Conclusions SG can reduce the maximum stress in the vertebra and intervertebral discs, offering better biomechanical performance and improved stability than IG.
Collapse
Affiliation(s)
- Chengqiang Zhou
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Department of Spine Surgery, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Xiao Meng
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Shaolong Huang
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Department of Spine Surgery, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Han Chen
- Department of Spine Surgery, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Haibin Zhou
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Yifeng Liao
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Zhongjian Tang
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Xu Zhang
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
- Graduate School of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Hua Li
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Wei Sun
- Department of Spine Surgery, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
| | - Yunqing Wang
- Department of Spine Surgery, The Second Affiliated Hospital of Xuzhou Medical University, Xuzhou, Jiangsu, China
| |
Collapse
|
6
|
Guo LX, Liu J. Topology optimization and dynamic characteristic evaluation of W-shaped interspinous process device. Comput Methods Biomech Biomed Engin 2023; 26:1610-1619. [PMID: 36200492 DOI: 10.1080/10255842.2022.2129968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 09/21/2022] [Accepted: 09/25/2022] [Indexed: 11/03/2022]
Abstract
For reducing the adjacent segment degeneration of the lumbar spine, the interspinous process device as a kind of flexible non-fusion device was designed to overcome the deficiencies associated with rigid fusion devices. However, it was not clear how the interspinous process device influenced the human spine system, especially the lumbar spine under a vibration environment. This study was designed to evaluate the effect of StenoFix under the vibration condition and also to optimize the structure of the device to obtain better biomechanical performance. A finite element model of the intact lumbar spine was developed and validated. The surgical finite element model was constructed by implanting the interspinous process device StenoFix. Using topology optimization, a new device StenoFix-new was redesigned. The results showed that the interspinous process device decreased vibration amplitudes of annulus stress and intradiscal pressure under vibration at the surgical level. The redesigned StenoFix-new with the smaller stiffness exhibited a better dynamic flexibility performance than StenoFix. In addition, the range of motions of StenoFix-new was closer to the intact model than StenoFix at the surgical level. These results might encourage the designers to give more consideration to the dynamic characteristics of the human spine on the premise of ensuring the safety and strength of implanted devices.
Collapse
Affiliation(s)
- Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| | - Juan Liu
- School of Mechanical Engineering and Automation, Northeastern University, Shenyang, China
| |
Collapse
|
7
|
Biomechanical and clinical studies on lumbar spine fusion surgery: a review. Med Biol Eng Comput 2023; 61:617-634. [PMID: 36598676 DOI: 10.1007/s11517-022-02750-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Accepted: 12/22/2022] [Indexed: 01/05/2023]
Abstract
Low back pain is associated with degenerative disc diseases of the spine. Surgical treatment includes fusion and non-fusion types. The gold standard is fusion surgery, wherein the affected vertebral segment is fused. The common complication of fusion surgery is adjacent segment degeneration (ASD). The ASD often leads to revision surgery, calling for a further fusion of adjacent segments. The existing designs of nonfusion type implants are associated with clinical problems such as subsidence, difficulty in implantation, and the requirement of revision surgeries. Various surgical approaches have been adopted by the surgeons to insert the spinal implants into the affected segment. Over the years, extensive biomechanical investigations have been reported on various surgical approaches and prostheses to predict the outcomes of lumbar spine implantations. Computer models have been proven to be very effective in identifying the best prosthesis and surgical procedure. The objective of the study was to review the literature on biomechanical studies for the treatment of lumbar spinal degenerative diseases. A critical review of the clinical and biomechanical studies on fusion spine surgeries was undertaken. The important modeling parameters, challenges, and limitations of the current studies were identified, showing the future research directions.
Collapse
|
8
|
Hsu FC, Chen CS, Yao YC, Lin HH, Wang ST, Chang MC, Liu CL, Chou PH. Shorter screw lengths in dynamic Dynesys fixation have less screw loosening: From clinical investigation to finite-element analysis. J Chin Med Assoc 2023; 86:330-337. [PMID: 36729417 DOI: 10.1097/jcma.0000000000000864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
BACKGROUND The dynamic Dynesys Stabilization System preserves lumbar mobility at instrumented levels. This study investigated the effect of screw length on screw loosening (SL) after dynamic Dynesys fixation and screw displacement during lumbar motion, using clinical investigation and finite-element (FE) analysis. METHODS Clinical data of 50 patients with degenerative spondylolisthesis treated with decompression and Dynesys fixation in 2011 were analyzed retrospectively. Horizontal sliding displacement and vertical displacement of screw tips at L4 were analyzed postoperatively using displacement-controlled FE analysis at the L4-L5 level with screw lengths 45 (long screw), 36 (median screw), and 27 (short screw), and 6.4 mm in diameter, under flexion, extension, lateral bending, and rotation. RESULTS In 13 patients (13/50, 26%), 40 screws (40/266, 15%) were loose at mean follow-up of 101.3 ± 4.4 months. Radiographic SL at 35, 40, 45, and 50 mm were 7.7%, 10.7%, 12.1%, and 37.5%, respectively, regardless of the fixation level ( p = 0.009). FE analysis revealed that the long screw model with corresponding longer lever arm had maximal horizontal sliding displacement under all directions and maximal vertical displacement, except for lateral bending. CONCLUSION Shorter screws in Dynesys fixation may help avoid dynamic SL. Clinically, 50 mm screws showed the greatest SL and median screw screws demonstrated the least displacement biomechanically.
Collapse
Affiliation(s)
- Fang-Chi Hsu
- Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
| | - Chen-Sheng Chen
- Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
| | - Yu-Cheng Yao
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Orthopedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Hsi-Hsien Lin
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Orthopedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Shih-Tien Wang
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Orthopedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Ming-Chau Chang
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Orthopedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Chien-Lin Liu
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Orthopedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| | - Po-Hsin Chou
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC
- Department of Orthopedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC
| |
Collapse
|
9
|
Kim CJ, Son SM, Choi SH, Ryu D, Lee C. Spinal stability analysis of lumbar interbody fusion according to pelvic type and cage angle based on simplified spinal model with various pelvic indices. Front Bioeng Biotechnol 2022; 10:1002276. [PMID: 36277403 PMCID: PMC9585289 DOI: 10.3389/fbioe.2022.1002276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 09/16/2022] [Indexed: 11/13/2022] Open
Abstract
Recently, the objectives of lumbar interbody fusion (LIF) have been extended to include the correction of broader/relative indications in addition to spinal fixation. Accordingly, LIF must be optimized for sagittal alignment while simultaneously achieving decompression. Therefore, a representative model classified into three pelvic types, i.e., neutral pelvis (NP), anterior pelvis (AP), and retroverted pelvis (RP), was selected according to the pelvic index, and LIF was performed on each representative model to analyze Lumbar lordosis (LL) and the corresponding equivalent stress. The finite element (FE) model was based on a sagittal 2D X-ray image. The calculation efficiency and convergence were improved by simplifying the modeling of the vertebral body in general and its posterior portion in particular. Based on the position of the pelvis, according to the pelvic shape, images of patients were classified into three types: AP, RP, and NP. Subsequently, representative images were selected for each type. The fixation device used in the fusion model was a pedicle screw and a spinal rod of a general type. PEEK was used as the cage material, and the cage shape was varied by using three different cage angles: 0°, 4°, and 8°. Spinal mobility: The pelvic type with the highest range of motion (ROM) for the spine was the NP type; the AP type had the highest LL. Under a combination load, the NP type exhibited the highest lumbar flexibility (LF), which was 2.46° lower on average compared to the case where a pure moment was applied. Equivalent stress on the spinal fixation device: The equivalent stress acting on the vertebrae was lowest when cage 0 was used for the NP and AP type. For the RP type, the lowest equivalent stress on the vertebrae was observed when cage 4 was used. Finally, for the L5 upper endplate, the stress did not vary significantly for a given type of cage. In conclusion, there was no significant difference in ROM according to cage angle, and the highest ROM, LL and LF were shown in the pelvic shape of NP type. However, when comparing the results with other pelvic types, it was not possible to confirm that LF is completely dependent on LL and ROM.
Collapse
Affiliation(s)
- Cheol-Jeong Kim
- Department of Biomedical Engineering, Graduate School, Pusan National University, Busan, South Korea
| | - Seung Min Son
- Department of Orthopaedic Surgery, Pusan National University Yangsan Hospital, Yangsan, South Korea
| | - Sung Hoon Choi
- Department of Orthopaedic Surgery, Hanyang University College of Medicine, Seoul, South Korea
| | - Dongman Ryu
- Medical Research Institute, Pusan National University, Busan, South Korea
| | - Chiseung Lee
- Department of Convergence Medicine and Biomedical Engineering, School of Medicine, Pusan National University, South Korea
- Biomedical Research Institute, Pusan National University Hospital, Busan, South Korea
- *Correspondence: Chiseung Lee,
| |
Collapse
|
10
|
Dai H, Liu Y, Han Q, Zhang A, Chen H, Qu Y, Wang J, Zhao J. Biomechanical comparison between unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: A finite element analysis. Front Bioeng Biotechnol 2022; 10:978917. [PMID: 36159704 PMCID: PMC9495612 DOI: 10.3389/fbioe.2022.978917] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Accepted: 08/15/2022] [Indexed: 11/23/2022] Open
Abstract
Background and objective: The osteoporotic vertebral compression fracture (OVCF) has an incidence of 7.8/1000 person-years at 55–65 years. At 75 years or older, the incidence increases to 19.6/1000 person-years in females and 5.2–9.3/1000 person-years in males. To solve this problem, percutaneous vertebroplasty (PVP) was developed in recent years and has been widely used in clinical practice to treat OVCF. Are the clinical effects of unilateral percutaneous vertebroplasty (UPVP) and bilateral percutaneous vertebroplasty (BPVP) the same? The purpose of this study was to compare biomechanical differences between UPVP and BPVP using finite element analysis. Materials and methods: The heterogeneous assignment finite element (FE) model of T11-L1 was constructed and validated. A compression fracture of the vertebral body was performed at T12. UPVP and BPVP were simulated by the difference in the distribution of bone cement in T12. Stress distributions and maximum von Mises stresses of vertebrae and intervertebral discs were compared. The rate of change of maximum displacement between UPVP and BPVP was evaluated. Results: There were no obvious high-stress concentration regions on the anterior and middle columns of the T12 vertebral body in BPVP. Compared with UPVP, the maximum stress on T11 in BPVP was lower under left/right lateral bending, and the maximum stress on L1 was lower under all loading conditions. For the T12-L1 intervertebral disc, the maximum stress of BPVP was less than that of UPVP. The maximum displacement of T12 after BPVP was less than that after UPVP under the six loading conditions. Conclusion: BPVP could balance the stress of the vertebral body, reduce the maximum stress of the intervertebral disc, and offer advantages in terms of stability compared with UPVP. In summary, BPVP could reduce the incidence of postoperative complications and provide promising clinical effects for patients.
Collapse
Affiliation(s)
| | | | | | | | | | - Yang Qu
- *Correspondence: Yang Qu, ; Jincheng Wang,
| | | | | |
Collapse
|
11
|
Sanjay D, Bhardwaj JS, Kumar N, Chanda S. Expandable pedicle screw may have better fixation than normal pedicle screw: preclinical investigation on instrumented L4-L5 vertebrae based on various physiological movements. Med Biol Eng Comput 2022; 60:2501-2519. [DOI: 10.1007/s11517-022-02625-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 06/24/2022] [Indexed: 10/17/2022]
|
12
|
Hsieh JY, Chen CS, Chuang SM, Wang JH, Chen PQ, Huang YY. Finite element analysis after rod fracture of the spinal hybrid elastic rod system. BMC Musculoskelet Disord 2022; 23:816. [PMID: 36008782 PMCID: PMC9413940 DOI: 10.1186/s12891-022-05768-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Accepted: 08/14/2022] [Indexed: 11/18/2022] Open
Abstract
Background The spinal hybrid elastic (SHE) rod dynamic stabilization system can provide sufficient spine support and less adjacent segment stress. This study aimed to investigate the biomechanical effects after the internal fracture of SHE rods using finite element analysis. Methods A three-dimensional nonlinear finite element model was developed. The SHE rod comprises an inner nitinol stick (NS) and an outer polycarbonate urethane (PCU) shell (PS). The fracture was set at the caudal third portion of the NS, where the maximum stress occurred. The resultant intervertebral range of motion (ROM), intervertebral disc stress, facet joint contact force, screw stress, NS stress, and PCU stress were analyzed. Results When compared with the intact spine model, the overall trend was that the ROM, intervertebral disc stress, and facet joint force decreased in the implanted level and increased in the adjacent level. When compared with the Ns-I, the trend in the Ns-F decreased and remained nearly half effect. Except for torsion, the PS stress of the Ns-F increased because of the sharing of NS stress after the NS fracture. Conclusions The study concluded the biomechanical effects still afford nearly sufficient spine support and gentle adjacent segment stress after rod fracture in a worst-case scenario of the thinnest PS of the SHE rod system. Supplementary Information The online version contains supplementary material available at 10.1186/s12891-022-05768-x.
Collapse
Affiliation(s)
- Jui-Yang Hsieh
- Department of Biomedical Engineering, National Taiwan University, No. 7, Yulu Rd., Wuhu Village, Jinshan Dist., New Taipei City, 20844, Taiwan (R.O.C.).,Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei, Taiwan (R.O.C.).,Department of Orthopedic Surgery, National Taiwan University Hospital, Jinshan Branch, Taipei, Taiwan (R.O.C.)
| | - Chen-Sheng Chen
- Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei, Taiwan (R.O.C.)
| | - Shao-Ming Chuang
- Department of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei, Taiwan (R.O.C.)
| | - Jyh-Horng Wang
- Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei, Taiwan (R.O.C.)
| | - Po-Quang Chen
- Department of Orthopedic Surgery, National Taiwan University Hospital, Taipei, Taiwan (R.O.C.)
| | - Yi-You Huang
- Department of Biomedical Engineering, National Taiwan University, No. 7, Yulu Rd., Wuhu Village, Jinshan Dist., New Taipei City, 20844, Taiwan (R.O.C.).
| |
Collapse
|
13
|
Biomechanical Comparison between Isobar and Dynamic-Transitional Optima (DTO) Hybrid Lumbar Fixators: A Lumbosacral Finite Element and Intersegmental Motion Analysis. BIOMED RESEARCH INTERNATIONAL 2022; 2022:8273853. [PMID: 35845942 PMCID: PMC9286886 DOI: 10.1155/2022/8273853] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Accepted: 06/27/2022] [Indexed: 11/18/2022]
Abstract
Biomechanical performance of longitudinal component in dynamic hybrid devices was evaluated to display the load-transfer effects of Dynesys cord spacer or Isobar damper-joint dynamic stabilizer on junctional problem based on various disc degenerations. The dynamic component was adapted at the mildly degenerative L3–L4 segment, and the static component was fixed at the moderately degenerative L4–L5 segment under a displacement-controlled mode for the finite element study. Furthermore, an intersegmental motion behavior was analyzed experimentally on the synthetic model under a load-controlled mode. Isobar or DTO hybrid fixator could reduce stress/motion at transition segment, but compensation was affected at the cephalic adjacent segment more than the caudal one. Within the trade-off region (as a motion-preserving balance between the transition and adjacent segments), the stiffness-related problem was reduced mostly in flexion by a flexible Dynesys cord. In contrast, Isobar damper afforded the effect of maximal allowable displacement (more than peak axial stiffness) to reduce stress within the pedicle and at facet joint. Pedicle-screw travel at transition level was related to the extent of disc degeneration in Isobar damper-joint (more than Dynesys cord spacer) attributing to the design effect of axial displacement and angular rotation under motion. In biomechanical characteristics relevant to clinical use, longitudinal cord/damper of dynamic hybrid lumbar fixators should be designed with less interface stress occurring at the screw-vertebral junction and facet joint to decrease pedicle screw loosening/breakage under various disc degenerations.
Collapse
|
14
|
Talukdar RG, Saviour CM, Tiwarekar K, Dhara S, Gupta S. Bone Remodelling Around Solid and Porous Interbody Cages in the Lumbar Spine. J Biomech Eng 2022; 144:1140536. [PMID: 35484999 DOI: 10.1115/1.4054457] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Indexed: 11/08/2022]
Abstract
Spinal fusion is an effective surgical treatment for intervertebral disc degeneration. However, the consequences of implantation with interbody cages on load transfer and bone remodelling in the vertebral bodies has scarcely been investigated. Using detailed 3D models of an intact and implanted lumbar spine and the strain energy density based bone remodelling algorithm, this study investigated the evolutionary changes in bone density distributions around porous and solid interbody cages. Follower load technique and submodelling approach were employed to simulate applied loading conditions on the lumbar spine models. The study determined the relationship between mechanical properties and parametrical characteristics of porous Body-centered-cubic (BCC) models, which corroborated well with Gibson-Ashby and exponential regression models. Variations in porosity affected the peri-prosthetic stress distributions and bone remodelling around the cages. In comparison to the solid cage, stresses and strains in the cancellous bone decreased with an increase in cage porosity; whereas the range of motion increased. For the solid cage, increase in bone density of 20-28% was predicted in the L4 inferior and L5 superior regions; whereas the model with 78% porosity exhibited a small 3-5% change in bone density. An overall increase of 9-14% bone density was predicted in the L4 and L5 vertebrae after remodelling for solid interbody cages, which may influence disc degeneration in the adjacent segment. In comparison to the solid cage, an interbody cage with 65-78% porosity could be a viable and promising alternative, provided sufficient mechanical strength is offered.
Collapse
Affiliation(s)
- Rahul Gautam Talukdar
- Advanced Technology and Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Ceby Mullakkara Saviour
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Kaustubh Tiwarekar
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| | - Sanjay Gupta
- Advanced Technology and Development Centre, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India; Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721 302, West Bengal, India
| |
Collapse
|
15
|
Zhang M, Ren W, Mo Z, Li J, Pu F, Fan Y. Biomechanics of adjacent segment after three-level lumbar fusion, hybrid single-level semi-rigid fixation with two-level lumbar fusion. Comput Methods Biomech Biomed Engin 2021; 25:455-463. [PMID: 34338556 DOI: 10.1080/10255842.2021.1959557] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Multi-level spinal fusion has been reported in some cases to lead to adjacent segment disease (ASD) and proximal junctional kyphosis (PJK). The purpose of this study was to demonstrate a polyether-ether-ketone (PEEK) rod fixation system implanted adjacent to a two-level lumbar fusion would have a lower risk of PJK than three-level lumbar fusion, which was investigated by comparing the biomechanical effects on the adjacent level after surgical procedures. Four finite element (FE) models of the lumbar-sacral spine (intact model (INT), L4-S1 fusion model (L4-S1 FUS), L3-S1 fusion model (L3-S1 FUS), and single-level PEEK rod semi-rigid fixation adjacent to L4-S1 fusion model (FUSPRF)) were established. Displacement-controlled finite element (FE) analysis was used during the simulation. Compared with the two-level fusion model (L4-S1 FUS), both three-level implanted models (L3-S1 FUS and FUSPRF) showed an increase intersegmental rotation angle, and maximum von-Mises stress on the disc annulus. The results also showed that the intersegmental rotation, stress on the disc annulus and maximum stress on the rod were lower in the FUSPRF model than the L3-S1 FUS model. Though the maximum screw stress was higher in the FUSPRF model than the L3-S1 FUS model under all moments except for torsion, the maximum screw stress in the two models were far below the yield strength of titanium alloy. As the parameters above have been indicated as risk factors for PJK, it can be concluded that hybrid single-level PEEK rod semi-rigid fixation and two-level lumbar fusion have a lower risk of PJK than three-level lumbar fusion.
Collapse
Affiliation(s)
- Mingzheng Zhang
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, Key Laboratory of Neuro-functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, National Research Center for Rehabilitation Technical Aids, Beijing, P. R. China
| | - Weiyan Ren
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, Key Laboratory of Neuro-functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, National Research Center for Rehabilitation Technical Aids, Beijing, P. R. China
| | - Zhongjun Mo
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, Key Laboratory of Neuro-functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, National Research Center for Rehabilitation Technical Aids, Beijing, P. R. China
| | - Jian Li
- Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, Key Laboratory of Neuro-functional Information and Rehabilitation Engineering of the Ministry of Civil Affairs, National Research Center for Rehabilitation Technical Aids, Beijing, P. R. China
| | - Fang Pu
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, P. R. China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, School of Biological Science and Medical Engineering, Beihang University, Beijing, P. R. China
| |
Collapse
|
16
|
Prediction of complications and fusion outcomes of fused lumbar spine with or without fixation system under whole-body vibration. Med Biol Eng Comput 2021; 59:1223-1233. [PMID: 34080095 DOI: 10.1007/s11517-021-02375-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 04/29/2021] [Indexed: 10/21/2022]
Abstract
Lumbar fixator has been widely used, which can stabilize the lumbar spine and improve the fusion outcomes, but also lead to many complications. The effects of the internal fixator on biomechanical properties of the fused lumbar spine have been widely concerned for many years. However, most studies only considered the static loads and did not consider the effect of the fixator on the properties of the human lumbar spine under whole-body vibration (WBV). The purpose of this study is to investigate how the fixation system affects the biomechanical characteristics of the lumbar spine, fusion outcomes, and complications under WBV based on the finite element analysis. A three-dimensional nonlinear osteoligamentous finite element model of the intact L1-sacrum spine with muscles was established. A 5-Hz, 40-N sinusoidal vertical load supplemented with a 400-N preload was applied at L1 to simulate the vibration of the human body. For the adjacent segments, the fixation system may increase the risk of the adjacent segment disease under WBV. For the fused segments, the fixation system may decrease the risk of subsidence and cage failure including fatigue failure under WBV. The fixation system may provide a more stable and suitable environment for vertebral cell growth under WBV and lead to better fusion outcomes. This study reveals insights into the effect of the fixation system on the vibration characteristics of the lumbar and provides new information on the fixation system, fusion outcomes, complications, clinical evaluation, and selection of fixation system.
Collapse
|
17
|
Talukdar RG, Mukhopadhyay KK, Dhara S, Gupta S. Numerical analysis of the mechanical behaviour of intact and implanted lumbar functional spinal units: Effects of loading and boundary conditions. Proc Inst Mech Eng H 2021; 235:792-804. [PMID: 33832355 DOI: 10.1177/09544119211008343] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The objective of this study was to develop an improved finite element (FE) model of a lumbar functional spinal unit (FSU) and to subsequently analyse the deviations in load transfer owing to implantation. The effects of loading and boundary conditions on load transfer in intact and implanted FSUs and its relationship with the potential risk of vertebral fracture were investigated. The FE models of L1-L5 and L3-L4 FSUs, intact and implanted, were developed using patient-specific CT-scan dataset and segmentation of cortical and cancellous bone regions. The effect of submodelling technique, as compared to artificial boundary conditions, on the elastic behaviour of lumbar spine was examined. Applied forces and moments, corresponding to physiologic movements, were used as loading conditions. Results indicated that the loading and boundary conditions considerably affect stress-strain distributions within a FSU. This study, based on an improved FE model of a vertebra, highlights the importance of using the submodelling technique to adequately evaluate the mechanical behaviour of a FSU. In the intact FSU, strains of 200-400 µε were observed in the cancellous bone of vertebral body and pedicles. High equivalent stresses of 10-25 MPa and 1-5 MPa were generated around the pars interarticularis for cortical and cancellous regions, respectively. Implantation caused reductions of 85%-92% in the range of motion for all movements. Insertion of the intervertebral cage resulted in major deviations in load transfer across a FSU for all movements. The cancellous bone around cage experienced pronounced increase in stresses of 10-15 MPa, which indicated potential risk of failure initiation in the vertebra.
Collapse
Affiliation(s)
- Rahul Gautam Talukdar
- Advanced Technology and Development Centre, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, India
| | | | - Santanu Dhara
- School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, India
| | - Sanjay Gupta
- Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, West Bengal, India
| |
Collapse
|
18
|
Numerical Evaluation of Spinal Stability after Posterior Spinal Fusion with Various Fixation Segments and Screw Types in Patients with Osteoporotic Thoracolumbar Burst Fracture Using Finite Element Analysis. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11073243] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The aim of this study was to analyze the spinal stability and safety after posterior spinal fusion with various fixation segments and screw types in patients with an osteoporotic thoracolumbar burst fracture based on finite element analysis (FEA). To realize various osteoporotic vertebral fracture conditions on T12, seven cases of Young’s modulus, namely 0%, 1%, 5%, 10%, 25%, 50%, and 100% of the Young’s modulus, for vertebral bones under intact conditions were considered. Four types of fixation for thoracolumbar fracture on T12 (fixed with T11-L1, T10-T11-L1, T11-L1-L2, and T10-T11-L1-L2) were applied to the thoracolumbar fusion model. The following screw types were considered: pedicle screw (PS) and cortical screw (CS). Using FEA, four motions were performed on the fixed spine, and the stress applied to the screw, peri-implant bone (PIB), and intervertebral disc (IVD) and the range of motion (ROM) were calculated. The lowest ROM calculated corresponded to the T10-T11-L1-L2 model, while the closest to the intact situation was achieved in the T11-L1-L2 fixation model using PS. The lowest stress in the screw and PB was detected in the T10-T11-L1-L2 fixation model.
Collapse
|
19
|
Lo HJ, Chen HM, Kuo YJ, Yang SW. Effect of different designs of interspinous process devices on the instrumented and adjacent levels after double-level lumbar decompression surgery: A finite element analysis. PLoS One 2020; 15:e0244571. [PMID: 33378405 PMCID: PMC7773253 DOI: 10.1371/journal.pone.0244571] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 12/13/2020] [Indexed: 12/17/2022] Open
Abstract
Recently, various designs and material manufactured interspinous process devices (IPDs) are on the market in managing symptomatic lumbar spinal stenosis (LSS). However, atraumatic fracture of the intervening spinous process has been reported in patients, particularly, double or multiple level lumbar decompression surgery with IPDs. This study aimed to biomechanically investigate the effects of few commercial IPDs, namely DIAMTM, CoflexTM, and M-PEEK, which were implanted into the L2-3, L3-4 double-level lumbar spinal processes. A validated finite element model of musculoskeletal intact lumbar spinal column was modified to accommodate the numerical analysis of different implants. The range of motion (ROM) between each vertebra, stiffness of the implanted level, intra stress on the intervertebral discs and facet joints, and the contact forces on spinous processes were compared. Among the three implants, the Coflex system showed the largest ROM restriction in extension and caused the highest stress over the disc annulus at the adjacent levels, as well as the sandwich phenomenon on the spinous process at the instrumented levels. Further, the DIAM device provided a superior loading-sharing between the two bridge supports, and the M-PEEK system offered a superior load-sharing from the superior spinous process to the lower pedicle screw. The limited motion at the instrumented segments were compensated by the upper and lower adjacent functional units, however, this increasing ROM and stress would accelerate the degeneration of un-instrumented segments.
Collapse
Affiliation(s)
- Hao-Ju Lo
- Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.,Department of Orthopedic Surgery, Dali Branch, Jen-Ai Hospital, Taichung, Taiwan
| | - Hung-Ming Chen
- Department of Orthopedic Surgery, Ren-Ai Branch of Taipei City Hospital, Taipei, Taiwan
| | - Yi-Jie Kuo
- Department of Orthopedic Surgery, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.,Department of Orthopedic Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
| | - Sai-Wei Yang
- Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan
| |
Collapse
|
20
|
Bohn T, Lang SAJ, Roll S, Schrader H, Pumberger M, Büttner-Janz K. Meta-analyses comparing spine simulators with cadavers and finite element models by analysing range-of-motion data before and after lumbar total disc replacement. J Adv Res 2020; 26:29-41. [PMID: 33133681 PMCID: PMC7584673 DOI: 10.1016/j.jare.2020.06.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 05/19/2020] [Accepted: 06/20/2020] [Indexed: 11/26/2022] Open
Abstract
Data from two different in vitro test methods for the same evaluation subjects were compared. It was investigated whether spine simulators with real human cadavers (SSCs) and finite element models (FEMs) provide the same data exemplarily for range of motion (ROM) before and after insertion of motion-retaining devices. Only fifty-nine percent of SSC meta-analyses show restored ROM after insertion of the device compared to the intact spinal segment. In FEM meta-analyses, ROM is restored in ninety percent. Ten percent of ROM analyses show significantly different data between SSCs and FEMs. With regard to the included studies, data generated by SSCs and FEMs cannot be used unrestricted as alternative and complementary data. Our analysis provides a new approach to compare data from associated test methods.
Background Range-of-motion (ROM) data generated by the in vitro test methods of spine simulators with cadavers (SSCs) and finite element models (FEMs) are used alternatively and complementarily for in vitro evaluations. Aim of Review Our purpose is to compare exemplary segmental ROM data from SSCs and FEMs before and after ball-and-socket total disc replacement (bsTDR) to determine whether the two test methods provide the same data for the same evaluation subjects. Key Scientific Concepts of Review We performed 70 meta-analyses (MAs) and 20 additional comparative analyses based on data from 21 SSC studies used for 39 MAs and 16 FEM studies used for 31 MAs. Only fifty-nine percent (n = 23/39) of SSC MAs show a restored ROM after bsTDR, whereas in FEM MAs, the ROM is restored in ninety percent (n = 28/31). Among the analyses comparing data from the same spinal segments, motion directions and bsTDR, SSC and FEM data are significantly different in ten percent (n = 2/20). According to our results, data generated by SSCs and FEMs cannot be used as alternative and complementary data without restriction. The quality of the evaluation methods itself as well as potential technical reasons for the discrepant results were not our evaluation target. Further SSC and FEM data should be compared using the same approach.
Collapse
Affiliation(s)
- Tobias Bohn
- Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany.,Institute of Radiology, Ortenau Klinikum Offenburg-Kehl, Ebertplatz 12, 77654 Offenburg, Germany
| | - Susanne A J Lang
- Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Stephanie Roll
- Institute for Social Medicine, Epidemiology and Health Economics at Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Helene Schrader
- Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Matthias Pumberger
- Center for Musculoskeletal Surgery at Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany
| | - Karin Büttner-Janz
- Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany.,Büttner-Janz Spinefoundation, Meinekestraße 6, 10719 Berlin, Germany
| |
Collapse
|
21
|
Fan W, Guo LX. The effect of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole-body vibration. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 192:105441. [PMID: 32172078 DOI: 10.1016/j.cmpb.2020.105441] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Accepted: 03/07/2020] [Indexed: 06/10/2023]
Abstract
BACKGROUND AND OBJECTIVE Non-fusion dynamic stabilization surgery is increasingly popular for treating degenerative lumbar disc disease. However, changes in spine biomechanics after application of posterior dynamic fixation devices during whole-body vibration (WBV) remain unclear. The study aimed to examine the effects of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine to vertical WBV. METHODS By modifying L4-L5 segment of the healthy human L1-sacrum finite element model, single-level disc degeneration, dynamic fixation using the BioFlex system and anterior lumbar interbody fusion (ALIF) with rigid fixation were simulated, respectively. Dynamic responses of stress and strain in the spinal levels for the healthy, degenerated, BioFlex and ALIF models under an axial cyclic loading were investigated and compared. RESULTS The results showed that endplate stress at implant level was lower in the BioFlex model than in the degenerated and ALIF models, but stress of the connecting rod in the BioFlex system was greater than that in the rigid fixation system used in the ALIF. Compared with the healthy model, stress and strain responses in terms of disc bulge, annulus stress and nucleus pressure at adjacent levels were decreased in the degenerated, BioFlex and ALIF models, but no obvious difference was observed in these responses among the three models. CONCLUSIONS This study may be helpful to understand variations in vibration characteristics of the lumbar spine after application of non-fusion dynamic stabilization system.
Collapse
Affiliation(s)
- Wei Fan
- School of Mechanical Engineering and Automation, Northeastern University, No. 3-11, Wenhua Road, Heping District, Shenyang, 110819, China.
| | - Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, No. 3-11, Wenhua Road, Heping District, Shenyang, 110819, China
| |
Collapse
|
22
|
Liang Z, Cui J, Zhang J, He J, Tang J, Ren H, Ye L, Liang D, Jiang X. Biomechanical evaluation of strategies for adjacent segment disease after lateral lumbar interbody fusion: is the extension of pedicle screws necessary? BMC Musculoskelet Disord 2020; 21:117. [PMID: 32085708 PMCID: PMC7035718 DOI: 10.1186/s12891-020-3103-1] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Accepted: 01/30/2020] [Indexed: 12/26/2022] Open
Abstract
Background Adjacent segment disease (ASD) is a well-known complication after interbody fusion. Pedicle screw-rod revision possesses sufficient strength and rigidity. However, is a surgical segment with rigid fixation necessary for ASD reoperation? This study aimed to investigate the biomechanical effect of different instrumentation on lateral lumbar interbody fusion (LLIF) for ASD treatment. Methods A validated L2~5 finite element (FE) model was modified for simulation. ASD was considered the level cranial to the upper-instrumented segment (L3/4). Bone graft fusion in LLIF with bilateral pedicle screw (BPS) fixation occurred at L4/5. The ASD segment for each group underwent a) LLIF + posterior extension of BPS, b) PLIF + posterior extension of BPS, c) LLIF + lateral screw, and d) stand-alone LLIF. The L3/4 range of motion (ROM), interbody cage stress and strain, screw-bone interface stress, cage-endplate interface stress, and L2/3 nucleus pulposus of intradiscal pressure (NP-IDP) analysis were calculated for comparisons among the four models. Results All reconstructive models displayed decreased motion at L3/4. Under each loading condition, the difference was not significant between models a and b, which provided the maximum ROM reduction (73.8 to 97.7% and 68.3 to 98.4%, respectively). Model c also provided a significant ROM reduction (64.9 to 77.5%). Model d provided a minimal restriction of the ROM (18.3 to 90.1%), which exceeded that of model a by 13.1 times for flexion-extension, 10.3 times for lateral bending and 4.8 times for rotation. Model b generated greater cage stress than other models, particularly for flexion. The maximum displacement of the cage and the peak stress of the cage-endplate interface were found to be the highest in model d under all loading conditions. For the screw-bone interface, the stress was much greater with lateral instrumentation than with posterior instrumentation. Conclusions Stand-alone LLIF is likely to have limited stability, particularly for lateral bending and axial rotation. Posterior extension of BPS can provide reliable stability and excellent protective effects on instrumentation and endplates. However, LLIF with the use of an in situ screw may be an alternative for ASD reoperation.
Collapse
Affiliation(s)
- Ziyang Liang
- First Clinical Medical College, Guangzhou University of Chinese medicine, Guangzhou, 510405, China
| | - Jianchao Cui
- Department of Spinal Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Airport Road, Guangzhou City, 510405, Guangdong Province, China
| | - Jiarui Zhang
- First Clinical Medical College, Guangzhou University of Chinese medicine, Guangzhou, 510405, China
| | - Jiahui He
- First Clinical Medical College, Guangzhou University of Chinese medicine, Guangzhou, 510405, China
| | - Jingjing Tang
- Department of Spinal Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Airport Road, Guangzhou City, 510405, Guangdong Province, China
| | - Hui Ren
- Department of Spinal Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Airport Road, Guangzhou City, 510405, Guangdong Province, China
| | - Linqiang Ye
- Department of Spinal Surgery, The Dongguan hospital of Chinese Medicine, Dongguan, 523000, China
| | - De Liang
- Department of Spinal Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Airport Road, Guangzhou City, 510405, Guangdong Province, China
| | - Xiaobing Jiang
- Department of Spinal Surgery, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Airport Road, Guangzhou City, 510405, Guangdong Province, China.
| |
Collapse
|
23
|
Hsieh YY, Tsuang FY, Kuo YJ, Chen CH, Chiang CJ, Lin CL. Biomechanical analysis of single-level interbody fusion with different internal fixation rod materials: a finite element analysis. BMC Musculoskelet Disord 2020; 21:100. [PMID: 32059656 PMCID: PMC7023693 DOI: 10.1186/s12891-020-3111-1] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 02/03/2020] [Indexed: 12/11/2022] Open
Abstract
Background Lumbar spinal fusion with rigid spinal fixators as one of the high risk factors related to adjacent-segment failure. The purpose of this study is to investigate how the material properties of spinal fixation rods influence the biomechanical behavior at the instrumented and adjacent levels through the use of the finite element method. Methods Five finite element models were constructed in our study to simulate the human spine pre- and post-surgery. For the four post-surgical models, the spines were implanted with rods made of three different materials: (i) titanium rod, (ii) PEEK rod with interbody PEEK cage, (iii) Biodegradable rod with interbody PEEK cage, and (iv) PEEK cage without pedicle screw fixation (no rods). Results Fusion of the lumbar spine using PEEK or biodegradable rods allowed a similar ROM at both the fusion and adjacent levels under all conditions. The models with PEEK and biodegradable rods also showed a similar increase in contact forces at adjacent facet joints, but both were less than the model with a titanium rod. Conclusions Flexible rods or cages with non-instrumented fusion can mitigate the increased contact forces on adjacent facet joints typically found following spinal fixation, and could also reduce the level of stress shielding at the bone graft.
Collapse
Affiliation(s)
- Yueh-Ying Hsieh
- Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.,Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, Taiwan.,Department of Orthopedic Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan
| | - Fon-Yih Tsuang
- Division of Neurosurgery, Department of Surgery, National Taiwan University Hospital, Taipei, Taiwan.,Department of Traumatology, National Taiwan University Hospital, Taipei, Taiwan.,Institute of Biomedical Engineering, National Taiwan University, Taipei, Taiwan
| | - Yi-Jie Kuo
- Department of Orthopedic Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.,Department of Orthopedic Surgery, Taipei Municipal Wanfang Hospital, Taipei Medical University, Taipei, Taiwan
| | - Chia-Hsien Chen
- Department of Orthopedic Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.,Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei, Taiwan
| | - Chang-Jung Chiang
- Department of Orthopedics, Shuang Ho Hospital, Taipei Medical University, New Taipei City, Taiwan. .,Department of Orthopedic Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.
| | - Chun-Li Lin
- Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.
| |
Collapse
|
24
|
Material properties of human lumbar intervertebral discs across strain rates. Spine J 2019; 19:2013-2024. [PMID: 31326631 DOI: 10.1016/j.spinee.2019.07.012] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2019] [Revised: 07/16/2019] [Accepted: 07/17/2019] [Indexed: 02/03/2023]
Abstract
BACKGROUND CONTEXT The use of finite element (FE) methods to study the biomechanics of the intervertebral disc (IVD) has increased over recent decades due to their ability to quantify internal stresses and strains throughout the tissue. Their accuracy is dependent upon realistic, strain-rate dependent material properties, which are challenging to acquire. PURPOSE The aim of this study was to use the inverse FE technique to characterize the material properties of human lumbar IVDs across strain rates. STUDY DESIGN A human cadaveric experimental study coupled with an inverse finite element study. METHODS To predict the structural response of the IVD accurately, the material response of the constituent structures was required. Therefore, compressive experiments were conducted on 16 lumbar IVDs (39±19 years) to obtain the structural response. An FE model of each of these experiments was developed and then run through an inverse FE algorithm to obtain subject-specific constituent material properties, such that the structural response was accurate. RESULTS Experimentally, a log-linear relationship between IVD stiffness and strain rate was observed. The material properties obtained through the subject-specific inverse FE optimization of the annulus fibrosus (AF) fiber and AF fiber ground matrix allowed a good match between the experimental and FE response. This resulted in a Young modulus of AF fibers (-MPa) to strain rate (ε˙, /s) relationship of YMAF=31.5ln(ε˙)+435.5, and the C10 parameter of the Neo-Hookean material model of the AF ground matrix was found to be strain-rate independent with an average value of 0.68 MPa. CONCLUSIONS These material properties can be used to improve the accuracy, and therefore predictive ability of FE models of the spine that are used in a wide range of research areas and clinical applications. CLINICAL SIGNIFICANCE Finite element models can be used for many applications including investigating low back pain, spinal deformities, injury biomechanics, implant design, design of protective systems, and degenerative disc disease. The accurate material properties obtained in this study will improve the predictive ability, and therefore clinical significance of these models.
Collapse
|
25
|
Lo HJ, Chen CS, Chen HM, Yang SW. Application of an interspinous process device after minimally invasive lumbar decompression could lead to stress redistribution at the pars interarticularis: a finite element analysis. BMC Musculoskelet Disord 2019; 20:213. [PMID: 31092237 PMCID: PMC6518805 DOI: 10.1186/s12891-019-2565-5] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Accepted: 04/11/2019] [Indexed: 12/21/2022] Open
Abstract
Background An interspinous process device, the Device for Intervertebral Assisted Motion (DIAM™) designed to treat lumbar neurogenic disease secondary to the lumbar spinal stenosis, it provides dynamic stabilization after minimally invasive (MI) lumbar decompression. The current study was conducted using an experimentally validated L1-L5 spinal finite element model (FEM) to evaluate the limited decompression on range of motion (ROM) and stress distribution on a neural arch implanted with the DIAM. Methods The study simulated bilateral laminotomies with partial discectomy at L3-L4, as well as unilateral and bilateral laminotomies with partial discectomy combined with implementation of the DIAM at L3-L4. The ROM and maximum von Mises stresses in flexion, extension, lateral bending, and axial torsion were analyzed in response to the hybrid protocol in comparison with the intact model. Results The investigation revealed that decreased ROM, intradiscal stress, and facet joint force at the implant level, but considerably increased stress at the pars interarticularis were found during flexion and torsion at the L4, as well as during extension, lateral bending, and torsion at the L3, when the DIAM was implanted compared with the defect model. Conclusion The results demonstrate that the DIAM may be beneficial in reducing the symptoms of stress-induced low back pain. Nevertheless, the results also suggest that a surgeon should be cognizant of the stress redistribution at the pars interarticularis results from MI decompression plus the application of the interspinous process device.
Collapse
Affiliation(s)
- Hao-Ju Lo
- Department of Biomedical Engineering, National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei, 11221, Taiwan.,Department of Orthopedic Surgery, Dali Branch, Jen-Ai Hospital, 483 Dong Rong Rd, Dali, Taichung, Taiwan
| | - Chen-Sheng Chen
- Department of Physical Therapy and Assistive Technology, National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei, 11221, Taiwan
| | - Hung-Ming Chen
- Department of Orthopedic Surgery, Renai Branch, Taipei City Hospital, No. 10, Section 4, Ren'ai Road, Da'an District, Taipei City, 106, Taiwan
| | - Sai-Wei Yang
- Department of Biomedical Engineering, National Yang-Ming University, No.155, Sec.2, Linong Street, Taipei, 11221, Taiwan.
| |
Collapse
|
26
|
Guo LX, Yin JY. Finite element analysis and design of an interspinous device using topology optimization. Med Biol Eng Comput 2018; 57:89-98. [PMID: 29981052 DOI: 10.1007/s11517-018-1838-8] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Accepted: 04/27/2018] [Indexed: 11/24/2022]
Abstract
Recently, interspinous stabilization with Coflex-F implant has become an alternative to treat lumbar spinal stenosis (LSS). However, little attention focused on modifying the structure of the device to obtain the better clinic application. The purpose of this study was to design a new interspinous implant using topology optimization methods and evaluate its biomechanical performance. The finite element models of healthy lumbar spine and surgical lumbar spine with Coflex-F and Coflex-NEW (the new designed implant) were constructed. Finite element analysis was applied to each of the three models. The interspinous implant structure after topology optimization was remodeled at an 8% reduced volume compared with the Coflex-F device, and they can both provide stability in all motion at the surgical segment. Additionally, the advantage of Coflex-NEW was that it can decrease the von Mises stress of the implant structure in flexion, extension, torsion, and the spinous process in flexion, extension, and bending. The stress in spinous process with Coflex-NEW was well-distributed. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Li-Xin Guo
- School of Mechanical Engineering and Automation, Northeastern University, No. 3-11, Wenhua Road, Heping District, Shenyang, 110819, China.
| | - Jia-Yu Yin
- School of Mechanical Engineering and Automation, Northeastern University, No. 3-11, Wenhua Road, Heping District, Shenyang, 110819, China
| |
Collapse
|
27
|
Wang L, Kang J, Shi L, Fu J, Li D, Guo Z, Liu C, Dong S, Jiang X. Investigation into factors affecting the mechanical behaviours of a patient-specific vertebral body replacement. Proc Inst Mech Eng H 2018; 232:378-387. [PMID: 29383959 DOI: 10.1177/0954411918754926] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Most vertebral body implants that are currently designed and produced in batches have difficulty meeting the patient-specific demands. Moreover, several complications, including a low fusion rate, subsidence occurrence, and rod displacement, are associated with these implants. This study aims to investigate the effects of patient-specific geometric and clinical parameters on the biomechanics of a vertebral body replacement. A three-dimensional patient-specific vertebral body replacement model was established as the basic model for parametric studies, including the anatomic design of the endplates, tilting angle, thickness, and dislocation of the vertebral body implant. A finite element analysis was applied to determine the stress distribution of the vertebral body implant when under various loading conditions. The model with an anatomical interfacing design generates 75% less stress concentration compared to a flat design; the peak stress of the model with a tilted angle closely matching the replaced vertebra segment is decreased by 30%; and the thickness close to the cortical bone can offer better bone growth capability and long-term stability. Patient-specific geometrical parameters were found to significantly affect the biomechanics of a vertebral body replacement, and therefore, a design customized especially for the endplates is necessary for better stability and long-term longevity of the prostheses. Regardless of such progress, how to balance the stability of a vertebral body implant and the safety of the peripheral nervous system remains a clinical challenge.
Collapse
Affiliation(s)
- Ling Wang
- State Key Laboratory for Manufacturing System Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Jianfeng Kang
- State Key Laboratory for Manufacturing System Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Lei Shi
- Department of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi’an, China
| | - Jun Fu
- Department of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi’an, China
| | - Dichen Li
- State Key Laboratory for Manufacturing System Engineering, Xi’an Jiaotong University, Xi’an, China
| | - Zheng Guo
- Department of Orthopaedics, Xijing Hospital, The Fourth Military Medical University, Xi’an, China
| | - Chaozong Liu
- John Scale Centre for Biomedical Engineering, University College London, Royal National Orthopaedic Hospital, Stanmore, UK
| | - Shuangpeng Dong
- Tianjin Medical Device Supervision and Testing Center, Tianjin, China
| | - Xi Jiang
- Tianjin Medical Device Supervision and Testing Center, Tianjin, China
| |
Collapse
|
28
|
Biomechanical analysis of a new lumbar interspinous device with optimized topology. Med Biol Eng Comput 2018; 56:1333-1341. [PMID: 29307048 DOI: 10.1007/s11517-017-1767-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2016] [Accepted: 12/13/2017] [Indexed: 01/29/2023]
Abstract
Interspinous spacers used stand-alone preserve joint movement but provide little protection for diseased segments of the spine. Used as adjuncts with fusion, interspinous spacers offer rigid stability but may accelerate degeneration on adjacent levels. Our new device is intended to balance the stability and preserves motion provided by the implant. A new interspinous spacer was devised according to the results of topology optimization studies. Four finite element (FE) spine models were created that consisted of an intact spine without an implant, implantation of the novel, the device for intervertebral assisted motion (DIAM system), and the Dynesys system. All models were loaded with moments, and their range of motions (ROMs), peak disc stresses, and facet contact forces were analyzed. The limited motion segment ROMs, shielded disc stresses, and unloaded facet contact forces of the new devices were greater than those of the DIAM and Dynesys system at L3-L4 in almost all directions of movements. The ROMs, disc stresses, and facet contact forces of the new devices at L2-L3 were slightly greater than those in the DIAM system, but much lower than those in the Dynesys system in most directions. This study demonstrated that the new device provided more stability at the instrumented level than the DIAM system did, especially in lateral rotation and the bending direction. The device caused fewer adjacent ROMs, lower disc stresses, and lower facet contact forces than the Dynesys system did. Additionally, this study conducted topology optimization to design the new device and created a smaller implant for minimal invasive surgery.
Collapse
|
29
|
Efficient probabilistic finite element analysis of a lumbar motion segment. J Biomech 2017; 61:65-74. [DOI: 10.1016/j.jbiomech.2017.07.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 05/30/2017] [Accepted: 07/03/2017] [Indexed: 11/21/2022]
|
30
|
Chen HC, Wu JL, Huang SC, Zhong ZC, Chiu SL, Lai YS, Cheng CK. Biomechanical evaluation of a novel pedicle screw-based interspinous spacer: A finite element analysis. Med Eng Phys 2017. [PMID: 28622909 DOI: 10.1016/j.medengphy.2017.05.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Interspinous spacers have been designed to provide a minimally invasive surgical technique for patients with lumbar spinal stenosis or foraminal stenosis. A novel pedicle screw-based interspinous spacer has been developed in this study, and the aim of this finite element experiment was to investigate the biomechanical differences between the pedicle screw-based interspinous spacer (M-rod system) and the typical interspinous spacer (Coflex-F™). A validated finite element model of an intact lumbar spine was used to analyze the insertions of the Coflex-F™, titanium alloy M-rod (M-Ti), and polyetheretherketone M-rod (M-PEEK), independently. The range of motion (ROM) between each vertebrae, stiffness of the implanted level, the peak stress at the intervertebral discs, and the contact forces on spinous process were analyzed. Of all three devices, the Coflex-F™ provided the largest restrictions in extension, flexion and lateral bending. For intervertebral disc, the peak stress at the implanted segment decreased by 81% in the Coflex-F™, 60.2% in the M-Ti and 46.7% in the M-PEEK when compared to the intact model. For the adjacent segments, while the Coflex-F™ caused considerable increases in the ROM and disc stress, the M-PEEK only had small changes.
Collapse
Affiliation(s)
- Hsin-Chang Chen
- Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan; Division of Orthopedics, Taipei City Hospital, Heping Fuyou Branch (Heping), Taipei, Taiwan
| | - Jia-Lin Wu
- Department of Orthopedics, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan; Department of Orthopedics, Taipei Medical University Hospital, Taipei, Taiwan
| | - Shou-Chieh Huang
- Division of Medical Devices and Cosmetics, Taiwan Food and Drug Administration, Taipei, Taiwan
| | - Zheng-Cheng Zhong
- Orthopaedic Device Research Center, National Yang-Ming University, Taipei, Taiwan
| | - Shiu-Ling Chiu
- Orthopaedic Device Research Center, National Yang-Ming University, Taipei, Taiwan
| | - Yu-Shu Lai
- Orthopaedic Device Research Center, National Yang-Ming University, Taipei, Taiwan.
| | - Cheng-Kung Cheng
- Department of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan; Orthopaedic Device Research Center, National Yang-Ming University, Taipei, Taiwan.
| |
Collapse
|
31
|
Cappetti N, Naddeo A, Naddeo F, Solitro GF. Finite elements/Taguchi method based procedure for the identification of the geometrical parameters significantly affecting the biomechanical behavior of a lumbar disc. Comput Methods Biomech Biomed Engin 2015; 19:1278-85. [DOI: 10.1080/10255842.2015.1128529] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
32
|
Abstract
PURPOSE The primary goal of this Policy Statement is to educate patients, physicians, medical providers, reviewers, adjustors, case managers, insurers, and all others involved or affected by insurance coverage decisions regarding lumbar disc replacement surgery. PROCEDURES This Policy Statement was developed by a panel of physicians selected by the Board of Directors of ISASS for their expertise and experience with lumbar TDR. The panel's recommendation was entirely based on the best evidence-based scientific research available regarding the safety and effectiveness of lumbar TDR.
Collapse
|
33
|
Lin HM, Liu CL, Pan YN, Huang CH, Shih SL, Wei SH, Chen CS. Biomechanical analysis and design of a dynamic spinal fixator using topology optimization: a finite element analysis. Med Biol Eng Comput 2014; 52:499-508. [PMID: 24737048 DOI: 10.1007/s11517-014-1154-x] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2013] [Accepted: 03/31/2014] [Indexed: 01/31/2023]
Abstract
Surgeons often use spinal fixators to manage spinal instability. Dynesys (DY) is a type of dynamic fixator that is designed to restore spinal stability and to provide flexibility. The aim of this study was to design a new spinal fixator using topology optimization [the topology design (TD) system]. Here, we constructed finite element (FE) models of degenerative disc disease, DY, and the TD system. A hybrid-controlled analysis was applied to each of the three FE models. The rod structure of the topology optimization was modelled at a 39 % reduced volume compared with the rigid rod. The TD system was similar to the DY system in terms of stiffness. In contrast, the TD system reduced the cranial adjacent disc stress and facet contact force at the adjacent level. The TD system also reduced pedicle screw stresses in flexion, extension, and lateral bending.
Collapse
Affiliation(s)
- Hung-Ming Lin
- Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan
| | | | | | | | | | | | | |
Collapse
|
34
|
Biomechanical comparison of laminectomy, hemilaminectomy and a new minimally invasive approach in the surgical treatment of multilevel cervical intradural tumour: a finite element analysis. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2013; 22:2719-30. [PMID: 24013720 DOI: 10.1007/s00586-013-2992-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2013] [Revised: 08/11/2013] [Accepted: 08/29/2013] [Indexed: 12/14/2022]
Abstract
PURPOSE The objective of this study was to investigate the impact of the less invasive procedures of hemilaminectomy and unilateral multilevel interlaminar fenestration (UMIF) on the cervical spinal biomechanics. METHODS A validated nonlinear finite element model of the intact cervical spine (C2-C7) was modified to study the biomechanical changes as a result of surgical alteration for treatment of intradural tumours at C3-6 using multilevel laminectomy (ML), multilevel hemilaminectomy (MHL) and UMIF with or without unilateral graded facetectomy. RESULTS Under the load-controlled method, the greatest biomechanical changes occurred at the surgical segments. The largest increases occurred in flexion motions following ML approach with 70, 62 and 60 % increase at C3-4, C4-5 and C5-6, respectively. The increases were significantly reduced to no more than 14 % under MHL and UMIF. When combined with graded facetectomy, the changes in flexion under ML approach have a significantly further increase, up to 110 % at C3-4. The further increase was not significantly following MHL and UMIF, with no more than 31 % increase at C3-4, C4-5 and C5-6. The motion following UMIF was only slightly smaller in axial rotation than MHL. The maximum stresses in the annulus occurred during flexion in ML model, with 39, 34 and 38 % more stress than the intact at C3-4, C4-5 and C5-6, respectively. The increases of stress were significantly reduced to 5-7 % under MHL and UMIF. CONCLUSIONS The less invasive approaches of UMIF and MHL greatly preserved the flexion motion (more than 48 %) of the cervical spine compared with laminectomy, and the preserved motion mean the low-risk of postoperative spinal instability. UMIF and MHL also reduced the increased stress of annulus caused by ML, and the lesser stress will lower the risk of postoperative disc degeneration. The posterior bone elements play a slight role in spinal stability after removal of the attached ligaments.
Collapse
|
35
|
Shih SL, Liu CL, Huang LY, Huang CH, Chen CS. Effects of cord pretension and stiffness of the Dynesys system spacer on the biomechanics of spinal decompression- a finite element study. BMC Musculoskelet Disord 2013; 14:191. [PMID: 23777265 PMCID: PMC3706348 DOI: 10.1186/1471-2474-14-191] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2012] [Accepted: 06/14/2013] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND The Dynesys system provides stability for destabilized spines while preserving segmental motion. However, clinical studies have demonstrated that the Dynesys system does not prevent adjacent segment disease. Moreover, biomechanical studies have revealed that the stiffness of the Dynesys system is comparable to rigid fixation. Our previous studies showed that adjusting the cord pretension of the Dynesys system alleviates stress on the adjacent level during flexion. We also demonstrated that altering the stiffness of Dynesys system spacers can alleviate stress on the adjacent level during extension of the intact spine. In the present study, we hypothesized that omitting the cord preload and changing the stiffness of the Dynesys system spacers would abate stress shielding on adjacent spinal segments. METHODS Finite element models were developed for - intact spine (INT), facetectomy and laminectomy at L3-4 (DEC), intact spine with Dynesys system (IntDyWL), decompressed spine with Dynesys system (DecDyWL), decompressed spine with Dynesys system without cord preload (DecDyNL), and decompressed spine with Dynesys system assembled using spacers that were 0.8 times the standard diameter without cord pretension (DecDyNL0.8). These models were subjected to hybrid control for flexion, extension, axial rotation; and lateral bending. RESULTS The greatest decreases in range of motion (ROM) at the L3-4 level occurred for axial rotation and lateral bending in the IntDyWL model and for flexion and extension in the DecDyWL model. The greatest decreases in disc stress occurred for extension and lateral bending in the IntDyWL model and for flexion in the DecDyWL model. The greatest decreases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the DecDyWL model. The greatest increases in ROMs at L2-3 level occurred for flexion, axial rotation and lateral bending in IntDyWL model and for extension in the DecDyNL model. The greatest increases in disc stress occurred for flexion, axial rotation and lateral bending in the IntDyWL model and for extension in the DecDyNL model. The greatest increases in facet contact force occurred for extension and lateral bending in the DecDyNL model and for axial rotation in the IntDyWL model. CONCLUSIONS The results reveals that removing the Dynesys system cord pretension attenuates the ROMs, disc stress, and facet joint contact forces at adjacent levels during flexion and axial rotation. Removing cord pretension together with softening spacers abates stress shielding for adjacent segment during four different moments, and it provides enough security while not jeopardizes the stability of spine during axial rotation.
Collapse
Affiliation(s)
- Shih-Liang Shih
- Department of Orthopaedic Surgery, Zhong-Xing Branch of Taipei-City Hospital, Taipei, Taiwan
| | | | | | | | | |
Collapse
|
36
|
Pretension effects of the Dynesys cord on the tissue responses and screw-spacer behaviors of the lumbosacral construct with hybrid fixation. Spine (Phila Pa 1976) 2013; 38:E775-82. [PMID: 23486410 DOI: 10.1097/brs.0b013e318290fb2e] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN The pretension of the Dynesys cord was varied to evaluate its effects on both tissue responses and screw-spacer behaviors by the finite-element method. OBJECTIVE This study aimed to provide detailed information about the motion-preserving and load-shielding mechanisms of the Dynesys screw-spacer joint. SUMMARY OF BACKGROUND DATA Intuitively, higher cord pretension aims to ensure the occurrence of screw-spacer contact, thus making the spacer the transmitter of the vertebral loads. However, detailed investigations of the cord-pretension effects have not yet been carried out. METHODS.: Using a validated lumbosacral model, the moderately degenerative L4-L5 segment was instrumented by a static fixator and the Dynesys fixator was further used to bridge a mildly degenerative L3-L4 segment. The pre-tended cord was modeled as an elastic spring with 0- and 300-N pretensions. The disc range-of-motion, disc stress, facet force, bone-screw stress, and screw-spacer force were chosen as comparison indices. RESULTS.: At the transition and adjacent segments, the range-of-motion differences between the 2 pretensions were 7.7% and 2.0% on average, respectively. The mechanical differences at the transition and adjacent segments were 9.0% and 5.2% (disc stress) and 9.4% and 9.1% (facet force), respectively. The results indicated that the cord pretension has a minor effect on the adjacent segments in comparison with the transition segment. However, the stress at the screw hub and force of the screw-spacer contact of the 300-N pretension were increased by 33.7% and 316.5% on average than without pretension, respectively. CONCLUSION The moment arm from the screw-cord center to the fulcrum is significantly less than that of vertebral loads. This leads to the minor effect of increasing the cord pretension on the responses of the adjacent segments. However, the cord pretension can significantly affect both screw-spacer force and bone-screw stress. LEVEL OF EVIDENCE 4.
Collapse
|
37
|
Finite element modeling mesh quality, energy balance and validation methods: A review with recommendations associated with the modeling of bone tissue. J Biomech 2013; 46:1477-88. [DOI: 10.1016/j.jbiomech.2013.03.022] [Citation(s) in RCA: 105] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2012] [Revised: 03/06/2013] [Accepted: 03/16/2013] [Indexed: 11/23/2022]
|
38
|
Comparison among load-, ROM-, and displacement-controlled methods used in the lumbosacral nonlinear finite-element analysis. Spine (Phila Pa 1976) 2013; 38:E276-85. [PMID: 23250233 DOI: 10.1097/brs.0b013e31828251f9] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
STUDY DESIGN For lumbosacral nonlinear analysis, the characteristics and differences between the load- and range-of-motion (ROM)-controlled methods (LCM and RCM) were compared using the numerical approach. OBJECTIVE This study aimed to discuss the LCM and RCM problems inherent in the method assumption and calculation procedure. A displacement-controlled method (DCM) based on the nodal movement at the lumbosacral top was proposed to offer a more efficient and equivalent comparison between the evaluated models. SUMMARY OF BACKGROUND DATA Both LCM and RCM have been extensively used to evaluate the biomechanical performance of lumbosacral implants. The LCM models were subject to the same loads as the intact model. The ROMs of the RCM models were controlled in the same way by iteratively adjusting some of the applied loads. However, the different strategies for adjusting lumbar loads might affect the predicted results and the execution might be inefficient. To the best of the authors' knowledge, the kinematic, mechanical, and computational comparisons between the 2 methods have still not been extensively investigated. METHODS An intact lumbosacral model was developed and validated with the cadaveric and numerical data from the literature studies. The intact model was then modified as a degenerative model, in which the moderately dehydrated L4-L5 segment was instrumented with transpedicular fixation. Lumbosacral flexion was simulated by ligament interconnection, muscular contraction, and weight compression. One LCM, 3 RCM, and 1 DCM models were developed to evaluate their effects on biomechanical results and the computational efficiency of the lumbosacral nonlinear analysis. RESULTS Both solution feasibility and calculation time were closely related to the loading sequence that was defined as the time curves of the load-incremental control. The calculation of the RCM models was the most time-consuming. The calculation time of the DCM model was about 17 times faster than that of the RCM counterparts. Apart from the LCM model, the total ROM of the other models could be consistently controlled with the same value as that of the intact model. The intersegmental ROMs of all models were quite comparable. However, the LCM model predicted the least value of the screw stress and averaged 15.6% and 19.9% less than the RCM and DCM models. In general, the computational efficiency between the models was the most different, followed by the mechanical stress; the kinematic results were the most comparable. CONCLUSION The superiority of the computational efficiency of the DCM compared with its counterparts makes it the improved strategy for executing lumbosacral nonlinear analysis.
Collapse
|
39
|
Chen SH, Lin SC, Tsai WC, Wang CW, Chao SH. Biomechanical comparison of unilateral and bilateral pedicle screws fixation for transforaminal lumbar interbody fusion after decompressive surgery--a finite element analysis. BMC Musculoskelet Disord 2012; 13:72. [PMID: 22591664 PMCID: PMC3503692 DOI: 10.1186/1471-2474-13-72] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2011] [Accepted: 04/20/2012] [Indexed: 11/29/2022] Open
Abstract
BACKGROUND Little is known about the biomechanical effectiveness of transforaminal lumbar interbody fusion (TLIF) cages in different positioning and various posterior implants used after decompressive surgery. The use of the various implants will induce the kinematic and mechanical changes in range of motion (ROM) and stresses at the surgical and adjacent segments. Unilateral pedicle screw with or without supplementary facet screw fixation in the minimally invasive TLIF procedure has not been ascertained to provide adequate stability without the need to expose on the contralateral side. This study used finite element (FE) models to investigate biomechanical differences in ROM and stress on the neighboring structures after TLIF cages insertion in conjunction with posterior fixation. METHODS A validated finite-element (FE) model of L1-S1 was established to implant three types of cages (TLIF with a single moon-shaped cage in the anterior or middle portion of vertebral bodies, and TLIF with a left diagonally placed ogival-shaped cage) from the left L4-5 level after unilateral decompressive surgery. Further, the effects of unilateral versus bilateral pedicle screw fixation (UPSF vs. BPSF) in each TLIF cage model was compared to analyze parameters, including stresses and ROM on the neighboring annulus, cage-vertebral interface and pedicle screws. RESULTS All the TLIF cages positioned with BPSF showed similar ROM (<5%) at surgical and adjacent levels, except TLIF with an anterior cage in flexion (61% lower) and TLIF with a left diagonal cage in left lateral bending (33% lower) at surgical level. On the other hand, the TLIF cage models with left UPSF showed varying changes of ROM and annulus stress in extension, right lateral bending and right axial rotation at surgical level. In particular, the TLIF model with a diagonal cage, UPSF, and contralateral facet screw fixation stabilize segmental motion of the surgical level mostly in extension and contralaterally axial rotation. Prominent stress shielded to the contralateral annulus, cage-vertebral interface, and pedicle screw at surgical level. A supplementary facet screw fixation shared stresses around the neighboring tissues and revealed similar ROM and stress patterns to those models with BPSF. CONCLUSIONS TLIF surgery is not favored for asymmetrical positioning of a diagonal cage and UPSF used in contralateral axial rotation or lateral bending. Supplementation of a contralateral facet screw is recommended for the TLIF construct.
Collapse
Affiliation(s)
- Shih-Hao Chen
- Department of Orthopaedics, Tzu-Chi General Hospital at Taichung and Tzu Chi University, Hualien, Taiwan
| | - Shang-Chih Lin
- Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Wen-Chi Tsai
- BoneCare Orthopedic Centers, Han-Chiung Clinics, Taipei, Taiwan
| | - Chih-Wei Wang
- Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Shih-Heng Chao
- Department of Mechanical Engineering, National Chiao-Tung University, Hsinchu, Taiwan
| |
Collapse
|
40
|
Chiang YF, Chiang CJ, Yang CH, Zhong ZC, Chen CS, Cheng CK, Tsuang YH. Retaining intradiscal pressure after annulotomy by different annular suture techniques, and their biomechanical evaluations. Clin Biomech (Bristol, Avon) 2012; 27:241-8. [PMID: 22000700 DOI: 10.1016/j.clinbiomech.2011.09.008] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2011] [Revised: 09/20/2011] [Accepted: 09/20/2011] [Indexed: 02/07/2023]
Abstract
BACKGROUND The adverse effects of annulotomy during lumbar discectomy have been increasingly recognized, and methods are developing to repair the annular defect. Biomechanically, the repair should retain the intra-nuclear pressure, which is doubtful using the current suture techniques. Therefore, a new suture technique was designed and tested to close a simpler type of annular incision. METHODS A new suture technique, the modified purse-string suture, was introduced into a re-validated nonlinear finite element human disk model after creating a standard transverse slit incision, as well as two other suture techniques: either two simple sutures, or a horizontal crossed suture, and compared their contact pressure on the cleft contact surface. Then, porcine lumbar endplate-disk-endplate complexes with transverse slit incisions were repaired using the three techniques. Quantitative discomanometry was then applied to compare their leakage pressure, as a parameter of disk integrity. FINDINGS In finite element model, the new technique created the greatest contact pressure along the suture range (the outer annulus), and generated a minimum contact pressure at the critical point, which was 68% and 55% higher than the other two suture techniques. In quantitative discomanometry, the new suture technique also had an average leakage pressure of 85% and 49% higher than the other two suture techniques. INTERPRETATION The modified purse-string suture can generate higher contact pressure than the other two techniques at finite element analysis and in realistic animal models, which aids in retaining intra-discal pressure, and should be encouraged in clinical practice.
Collapse
Affiliation(s)
- Yueh-Feng Chiang
- Department of Orthopaedic Surgery, Buddhist Tzu Chi General Hospital, Taichung Branch, No. 66 Sec. 1 Fongsing Road, Tanzih Township. Taichung County, Taiwan
| | | | | | | | | | | | | |
Collapse
|
41
|
Zhong ZC, Hung C, Lin HM, Wang YH, Huang CH, Chen CS. The influence of different magnitudes and methods of applying preload on fusion and disc replacement constructs in the lumbar spine: a finite element analysis. Comput Methods Biomech Biomed Engin 2012; 16:943-53. [PMID: 22224913 DOI: 10.1080/10255842.2011.645226] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
In a finite element (FE) analysis of the lumbar spine, different preload application methods that are used in biomechanical studies may yield diverging results. To investigate how the biomechanical behaviour of a spinal implant is affected by the method of applying the preload, hybrid-controlled FE analysis was used to evaluate the biomechanical behaviour of the lumbar spine under different preload application methods. The FE models of anterior lumbar interbody fusion (ALIF) and artificial disc replacement (ADR) were tested under three different loading conditions: a 150 N pressure preload (PP) and 150 and 400 N follower loads (FLs). This study analysed the resulting range of motion (ROM), facet contact force (FCF), inlay contact pressure (ICP) and stress distribution of adjacent discs. The FE results indicated that the ROM of both surgical constructs was related to the preload application method and magnitude; differences in the ROM were within 7% for the ALIF model and 32% for the ADR model. Following the application of the FL and after increasing the FL magnitude, the FCF of the ADR model gradually increased, reaching 45% at the implanted level in torsion. The maximum ICP gradually decreased by 34.1% in torsion and 28.4% in lateral bending. This study concluded that the preload magnitude and application method affect the biomechanical behaviour of the lumbar spine. For the ADR, remarkable alteration was observed while increasing the FL magnitude, particularly in the ROM, FCF and ICP. However, for the ALIF, PP and FL methods had no remarkable alteration in terms of ROM and adjacent disc stress.
Collapse
Affiliation(s)
- Zheng-Cheng Zhong
- a Department of Physical Therapy and Assistive Technology , National Yang-Ming University , 155, Section 2, Li-Nung Street, Taipei , Taiwan
| | | | | | | | | | | |
Collapse
|
42
|
Lo CC, Tsai KJ, Zhong ZC, Chen SH, Hung C. Biomechanical differences of Coflex-F and pedicle screw fixation combined with TLIF or ALIF – a finite element study. Comput Methods Biomech Biomed Engin 2011; 14:947-56. [DOI: 10.1080/10255842.2010.501762] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
43
|
Lo CC, Tsai KJ, Chen SH, Zhong ZC, Hung C. Biomechanical effect after Coflex and Coflex rivet implantation for segmental instability at surgical and adjacent segments: a finite element analysis. Comput Methods Biomech Biomed Engin 2011; 14:969-78. [DOI: 10.1080/10255842.2010.502894] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
44
|
Liu CL, Zhong ZC, Hsu HW, Shih SL, Wang ST, Hung C, Chen CS. Effect of the cord pretension of the Dynesys dynamic stabilisation system on the biomechanics of the lumbar spine: a finite element analysis. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2011; 20:1850-8. [PMID: 21523456 DOI: 10.1007/s00586-011-1817-3] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2010] [Revised: 03/21/2011] [Accepted: 04/13/2011] [Indexed: 11/24/2022]
Abstract
The Dynesys dynamics stabilisation system was developed to maintain the mobility of motion segment of the lumbar spine in order to reduce the incidence of negative effects at the adjacent segments. However, the magnitude of cord pretension may change the stiffness of the Dynesys system and result in a diverse clinical outcome, and the effects of Dynesys cord pretension remain unclear. Displacement-controlled finite element analysis was used to evaluate the biomechanical behaviour of the lumbar spine after insertion of Dynesys with three different cord pretensions. For the implanted level, increasing the cord pretension from 100 to 300 N resulted in an increase in flexion stiffness from 19.0 to 64.5 Nm/deg, a marked increase in facet contact force (FCF) of 35% in extension and 32% in torsion, a 40% increase of the annulus stress in torsion, and an increase in the high-stress region of the pedicle screw in flexion and lateral bending. For the adjacent levels, varying the cord pretension from 100 to 300 N only had a minor influence on range of motion (ROM), FCF, and annulus stress, with changes of 6, 12, and 9%, respectively. This study found that alteration of cord pretension affects the ROM and FCF, and annulus stress within the construct but not the adjacent segment. In addition, use of a 300 N cord pretension causes a much higher stiffness at the implanted level when compared with the intact lumbar spine.
Collapse
Affiliation(s)
- Chien-Lin Liu
- Department of Orthopaedic Surgery, Taipei-Veterans General Hospital, Taipei, Taiwan
| | | | | | | | | | | | | |
Collapse
|
45
|
Noailly J, Ambrosio L, Elizabeth Tanner K, Planell JA, Lacroix D. In silico evaluation of a new composite disc substitute with a L3-L5 lumbar spine finite element model. EUROPEAN SPINE JOURNAL : OFFICIAL PUBLICATION OF THE EUROPEAN SPINE SOCIETY, THE EUROPEAN SPINAL DEFORMITY SOCIETY, AND THE EUROPEAN SECTION OF THE CERVICAL SPINE RESEARCH SOCIETY 2011; 21 Suppl 5:S675-87. [PMID: 21380572 DOI: 10.1007/s00586-011-1716-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2009] [Revised: 01/26/2011] [Accepted: 02/06/2011] [Indexed: 10/18/2022]
Abstract
When the intervertebral disc is removed to relieve chronic pain, subsequent segment stabilization should restore the functional mechanics of the native disc. Because of partially constrained motions and the lack of intrinsic rotational stiffness ball-on-socket implants present many disadvantages. Composite disc substitutes mimicking healthy disc structures should be able to assume the role expected for a disc substitute with fewer restrictions than ball-on-socket implants. A biomimetic composite disc prototype including artificial nucleus fibre-reinforced annulus and endplates was modelled as an L4-L5 disc substitute within a L3-L5 lumbar spine finite element model. Different device updates, i.e. changes of material properties fibre distributions and volume fractions and nucleus placements were proposed. Load- and displacement-controlled rotations were simulated with and without body weight applied. The original prototype reduced greatly the flexibility of the treated segment with significant adjacent level effects under displacement-controlled or hybrid rotations. Device updates allowed restoring large part of the global axial and sagittal rotational flexibility predicted with the intact model. Material properties played a major role, but some other updates were identified to potentially tune the device behaviour against specific motions. All device versions altered the coupled intersegmental shear deformations affecting facet joint contact through contact area displacements. Loads in the bony endplates adjacent to the implants increased as the implant stiffness decreased but did not appear to be a strong limitation for the implant biomechanical and mechanobiological functionality. In conclusion, numerical results given by biomimetic composite disc substitutes were encouraging with greater potential than that offered by ball-on-socket implants.
Collapse
Affiliation(s)
- Jérôme Noailly
- Institute for Bioengineering of Catalonia Biomechanics and Mechanobiology, 4 Torre I, Planta 10, 08028 Barcelona, Spain.
| | | | | | | | | |
Collapse
|
46
|
|