Li Y, Yi P, Zou Z, Lu F, Zhang X, Zhang J. Finite element model with realistic bone geometries for the optimal design of internal fixation during the fibula healing process. Proc Inst Mech Eng H 2024; 238:207-218. [PMID: 38235731 DOI: 10.1177/09544119231221193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
A finite element model with realistic bone geometries is developed to design optimal internal fixation during the fibula healing process in this study. The effect of bone plate parameters on fibula fracture healing is studied. The relationship between differences in plate length, thickness and working length, and bone healing performance is focused. The optimal combination form of the bone plate parameters was selected by the orthogonal experimental design and fracture block strain to achieve bone healing maximize the performance. The model results show that the maximum equivalent force of the bone plate was below the material yield limit; the higher mean contact stresses in the bone fragments indicate that the bone plate is prone to higher contact stresses when they are long. The working length of the bone plate has a greater effect on callus healing than the thickness and length of the bone plate. The optimal internal fixation option for distal fibula fractures is achieved when it provides the stability required for internal fixation during bone healing. It ensures lower contact stresses in the fibula as well as maximum Young's modulus during callus healing process.
Collapse
Affiliation(s)
- Yafeng Li
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Peng Yi
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Zichun Zou
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Fengyuan Lu
- School of Mechanical Engineering, Tiangong University, Tianjin, China
- Tianjin Key Laboratory of Advanced Mechatronics Equipment Technology, Tiangong University, Tianjin, China
| | - Xi Zhang
- Department of Traumatology and Orthopedics, Tianjin Hospital, Tianjin, China
| | - Jing Zhang
- Department of Mechanical and Energy Engineering, Indiana University - Purdue University Indianapolis, IN, USA
| |
Collapse
|
2
|
Zhang C, Wen P, Xu Y, Fu Z, Ren G. Exploring Advanced Functionalities of Carbon Fiber-Graded PEEK Composites as Bone Fixation Plates Using Finite Element Analysis. MATERIALS (BASEL, SWITZERLAND) 2024; 17:414. [PMID: 38255583 PMCID: PMC10817601 DOI: 10.3390/ma17020414] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Revised: 01/10/2024] [Accepted: 01/12/2024] [Indexed: 01/24/2024]
Abstract
This study aims to address the challenges associated with conventional metallic bone fixation plates in biomechanical applications, such as stainless steel and titanium alloys, including stress shielding, allergic reactions, corrosion resistance, and interference with medical imaging. The use of materials with a low elastic modulus is regarded as an effective approach to overcome these problems. In this study, the impact of different types of chopped carbon fiber-reinforced polyether ether ketone (CCF/PEEK) functionally graded material (FGM) bone plates on stress shielding under static and instantaneous dynamic loading was explored using finite element analysis (FEA). The FGM bone plate models were established using ABAQUS and the user's subroutine USDFLD and VUSDFLD, and each model was established with an equivalent overall elastic modulus and distinctive distributions. The results revealed that all FGM bone plates exhibited lower stress shielding effects compared to metal bone plates. Particularly, the FGM plate with an elastic modulus gradually increased from the centre to both sides and provided maximum stress stimulation and the most uniform stress distribution within the fractured area. These findings offer crucial insights for designing implantable medical devices that possess enhanced mechanical adaptability.
Collapse
Affiliation(s)
- Chenggong Zhang
- School of Engineering and Materials Science, Queen Mary University of London, London E1 4NS, UK;
| | - Pihua Wen
- Institute of Aeronautics and Astronautics, School of Infrastructure Engineering, Nanchang University, Nanchang 330031, China
| | - Yigeng Xu
- School of Aerospace, Transport and Manufacturing, Cranfield University, Cranfield MK43 0AL, UK;
| | - Zengxiang Fu
- Faculty of Life Science, Northwestern Polytechnical University, Xi’an 710072, China;
| | - Guogang Ren
- School of Physics, Engineering and Computer Science, University of Hertfordshire, Hatfield AL10 9AB, UK
| |
Collapse
|
3
|
Niroomand MR, Arabbeiki M, Rouhi G. Optimization of thread configuration in dental implants through regulating the mechanical stimuli in neighboring bone. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 231:107376. [PMID: 36736135 DOI: 10.1016/j.cmpb.2023.107376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 12/12/2022] [Accepted: 01/24/2023] [Indexed: 06/18/2023]
Abstract
BACKGROUND AND OBJECTIVE The threads, as the most critical component of dental implants, transfer the imposed occlusal loads to the adjacent bone. Moreover, regulation of the mechanical stimuli in the implant adjacent bone is crucial to maximize the bone-implant construct stability. An optimal thread design can be resulted when the distribution of mechanical stimuli within the bone, and at the implant-bone interface, lie in an advised confined range. In this work, with the goal of finding the optimal thread design, which can provide the maximum level of stability, the effects of thread parameters, namely, thread depth, thread width, and thread pitch, together with upper and lower thread angles, on maximum principal strain within the cortical and cancellous bone, and shear strain at the implant-bone interface, were investigated. METHODS In this study, the response surface methodology (RSM), due to the central composite design (CCD), was employed to obtain a set of 53 experiments. Following that, they were numerically simulated using the finite element method (FEM). The polynomial regression model was then used to predict the response functions based on the magnitude of thread parameters. The effectiveness of each thread parameter was also evaluated through statistical tools. Moreover, the non-dominated sorting genetic algorithm (NSGA-II) was performed to find the optimum dimensions of the thread. RESULTS Through comparing the results obtained from analyzing initial and optimized configuration of threads, it was shown that the latter causes a reduction in the maximum principal strains in cancellous and cortical bones by about 25% and 30%, respectively, which is in favor of making a higher quality bone, and thus greater stability in dental implant-bone construct. Moreover, the maximum shear strains at the implant-bone interface in different planes were reduced by about 40%, in the optimized thread, compared with the initial design. CONCLUSIONS The optimized design found in this study is a buttress thread with a fine pitch, but deep thread, which keeps the mechanical stimuli in a safe range to grant an acceptable level of stability.
Collapse
Affiliation(s)
| | - Masoud Arabbeiki
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
| | - Gholamreza Rouhi
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| |
Collapse
|
4
|
A finite element study on femoral locking compression plate design using genetic optimization method. J Mech Behav Biomed Mater 2022; 131:105202. [DOI: 10.1016/j.jmbbm.2022.105202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 02/15/2022] [Accepted: 03/25/2022] [Indexed: 11/23/2022]
|
5
|
Mohandes Y, Tahani M, Rouhi G. Osteosynthesis of diaphyseal tibia fracture with locking compression plates: A numerical investigation using Taguchi and ANOVA. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2021; 37:e3528. [PMID: 34486240 DOI: 10.1002/cnm.3528] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2021] [Accepted: 08/29/2021] [Indexed: 06/13/2023]
Abstract
Performance of the locking compression plate (LCP) is a multifactorial function. The control parameters of plating, such as geometries, material properties, and physical constraints of the LCP components, affect basic functions associated with the bone fixation, including the extent of stress shielding and subsequent bone remodeling, strength and stability of the bone-LCP construct, and performance of secondary bone healing. The main objectives of this research were as follows: (1) to find the appropriate values of control parameters of an LCP construct to achieve the optimized performance throughout bone healing; and (2) to unravel relationships between LCP parameters and the LCP's performance. Different values for the plate/screw modulus of elasticity (E), plate width (W), plate thickness (T), screw diameter (D), bone-plate offset (O), and screw configuration (C), as six control parameters, were considered at five different levels. Taguchi method was adopted to create trial combinations of control parameters and determining the best set of parameters, which can optimize the overall performance of the LCP. All design cases were analyzed using the finite element method. The optimal set of control parameters consisting of 150 GPa, 12 mm, 4 mm, 5.5 mm, 2 mm, and 123,678 were determined for E, W, T, D, O, and C, respectively. Furthermore, ANOVA was used to rank the most influential parameters on each function of the LCP fixation. In the overall performance of the LCP fixation, E, D, T, C, W, and O showed a contribution percentage of 46%, 22%, 10%, 11%, 8%, and 3%, respectively.
Collapse
Affiliation(s)
- Yousof Mohandes
- Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Masoud Tahani
- Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Gholamreza Rouhi
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| |
Collapse
|
6
|
Mohandes Y, Tahani M, Rouhi G, Tahami M. A mechanobiological approach to find the optimal thickness for the locking compression plate: Finite element investigations. Proc Inst Mech Eng H 2021; 235:408-418. [PMID: 33427059 DOI: 10.1177/0954411920985757] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study aimed at finding the acceptable range, and the optimal value for the locking compression plate (LCP) thickness (THK), through simulating the osteogenic pathway of bone healing, and by checking bone-plate construct's strength and stability. To attain the goals of this research, a multi-objective approach was adopted, which should trade-off between some conflicting objectives. A finite element model of the long bone-plate construct was made first, and validated against an experimental study. The validated model was then employed to determine the initial strength and stability of the bone-plate construct, for the time right after surgery, for various thicknesses of the LCP. Afterward, coupling with a mechano-regulatory algorithm, the iterative process of bone healing was simulated, and follow up was made for each LCP thickness, over the first 16 post-operative weeks. Results of this study regarding the sequence of tissue evolution inside the fracture gap, showed a similar trend with the existing in-vivo data. For the material and structural properties assigned to the bone-plate construct, in this study, an optimal thickness for the LCP was found to be 4.7 mm, which provides an enduring fixation through secondary healing, whereas for an LCP with a smaller or greater thickness, either bone-implant failure, unstable fixation, impaired fracture consolidation, or primary healing may occur. This result is in agreement with a recent study, that has employed a comprehensive optimization approach to find the optimal thickness.
Collapse
Affiliation(s)
- Yousof Mohandes
- Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Masoud Tahani
- Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Gholamreza Rouhi
- Department of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | - Mohammad Tahami
- Bone and Joint Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
7
|
Ghadami F, Saber-Samandari S, Rouhi G, Amani Hamedani M, Dehghan MM, Farzad Mohajeri S, Mashhadi-Abbas F, Gholami H. The effects of bone implants' coating mechanical properties on osseointegration: In vivo, in vitro, and histological investigations. J Biomed Mater Res A 2019; 106:2679-2691. [PMID: 29901269 DOI: 10.1002/jbm.a.36465] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 04/20/2018] [Accepted: 05/11/2018] [Indexed: 12/26/2022]
Abstract
The main goal of this work was to investigate the effects of implants coatings' mechanical properties and morphology on the osseointegration. In order to produce different mechanical properties of coatings, two thermal spray techniques, high velocity oxy-fuel (HVOF) and air plasma spray (APS) were employed. Titanium pins were coated and implanted into the distal femurs and proximal tibias of fifteen New Zealand white rabbits, equally distributed in three study groups, and a total of 20 pins implanted in each group. Eight weeks after insertion, the rabbits were euthanized and the femur samples were taken out for biomechanical tests and tibia samples for histological evaluations of osseointegration. Scanning electron microscopy results showed enhanced density and a better morphology of HVOF coatings, compared to APS samples, and X-ray diffraction characterized an enhanced crystallinity of HVOF coatings. Nanoindentation tests revealed greater hardness and elastic modulus of HVOF coatings, whereas greater tensile residual stress and more pronounced creep was observed for APS coatings. Neither in biomechanical tests, nor in the histological analyses, a significant difference was observed between HVOF and APS coated samples (p > 0.05, and p > 0.05, respectively). The lack of significant difference between the HVOF and APS coated implants' osseointegration rejected our hypothesis to have a more enhanced osseointegration due to a better morphology, as well as stronger mechanical properties of HA coatings. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 2679-2691, 2018.
Collapse
Affiliation(s)
- Farhad Ghadami
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | | | - Gholamreza Rouhi
- Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
| | | | - Mohammad Mehdi Dehghan
- Department of Surgery and Radiology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
| | - Saeed Farzad Mohajeri
- Department of Surgery and Radiology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
| | - Fatemeh Mashhadi-Abbas
- Department of Oral and Maxillofacial Pathology, Dental School, Shahid Beheshti University of Medical Science, Tehran, Iran
| | - Hossein Gholami
- Department of Pathology, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran
| |
Collapse
|
8
|
Abstract
There are many unanswered questions about giant cell tumor (GCT) treatment and not enough attention is paid to the biomechanics of the current treatment methods. Treatment methods have not changed much, and the best method remains controversial to some degree, due to the lack of adequate clinical and biomechanical investigations. Biomechanical tests, including in vitro mechanical experiments combined with finite element analysis, are very helpful in assessing the efficiency of the surgical methods employed and in determining the optimal method of surgery. Tests can be tailored to meet a patient’s needs, while limiting postoperative complications. One of the complications, following tumor surgery, is the frequency of postoperative fractures. In order to prevent postoperative fractures, defect reconstruction is recommended. The reconstruction usually consists of defect infilling with bone cement, and in the case of large defects cement augmentation is employed. Whether cement augmentation is essential and offers enough mechanical strength and what is the best fixation device for cement augmentation are areas of debate. In this article, the biomechanical studies comparing different methods of tumor surgery and cement augmentation, highlighting the areas needing more attention to advance GCT treatment, are critically reviewed. Based on our review, we recommend a biomechanical criterion for the essence of defect reconstruction, which must include patient specific factors, in addition to the tumor geometrical properties.
Collapse
|
9
|
Jiménez-Delgado JJ, Paulano-Godino F, PulidoRam-Ramírez R, Jiménez-Pérez JR. Computer assisted preoperative planning of bone fracture reduction: Simulation techniques and new trends. Med Image Anal 2016; 30:30-45. [PMID: 26849422 DOI: 10.1016/j.media.2015.12.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 11/26/2015] [Accepted: 12/17/2015] [Indexed: 10/24/2022]
|
10
|
Evans KR, Carey JP. Feasibility of a braided composite for orthopedic bone cast. Open Biomed Eng J 2013; 7:9-17. [PMID: 23459455 PMCID: PMC3583022 DOI: 10.2174/1874120701307010009] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Revised: 11/08/2012] [Accepted: 11/28/2012] [Indexed: 12/05/2022] Open
Abstract
A tubular braided composite bone cast for improving the efficiency and quality of bone fracture treatment is investigated. Finite element analysis was used to evaluate stress concentrations in fracture sites supported with plate and tubular casts. The stress in a plated bone is 768 % of that in a whole bone at the same location, while it is only 47 % in a bone with a tubular cast. Three unbroken synthetic humeri were mechanically tested using an in-vitro long bone testing procedure developed in-house to find their stiffness at 20° and 60° abduction; these were found to be 116.8 ± 1.5 N/mm and 20.63 ± 0.02 N/mm, respectively. A 2 cm gap osteotomy was cut through the diaphysis in each bone. The bones were casted with a Kevlar/Cold cure composite, with calculated braid angles and thicknesses that Closely matched bone propoerties. The stiffness tests were repeated, and the results were within 10 % of the unbroken bone. This novel method of bone casting is promising if other clinical challenges can be minimized.
Collapse
Affiliation(s)
- Katherine R Evans
- 4-9 MecE building, University of Alberta, Edmonton, Alberta, Canada, T6G 2G8
| | | |
Collapse
|