1
|
Liu X, Mohtasebi M, Safavi P, Fathi F, Haratbar SR, Chen L, Chen J, Bada HS, Chen L, Abu Jawdeh EG, Yu G. Wearable fiber-free optical sensor for continuous monitoring of neonatal cerebral blood flow and oxygenation. Pediatr Res 2024; 96:486-493. [PMID: 38503982 DOI: 10.1038/s41390-024-03137-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 02/15/2024] [Accepted: 03/01/2024] [Indexed: 03/21/2024]
Abstract
BACKGROUND Unstable cerebral hemodynamics places preterm infants at high risk of brain injury. We adapted an innovative, fiber-free, wearable diffuse speckle contrast flow-oximetry (DSCFO) device for continuous monitoring of both cerebral blood flow (CBF) and oxygenation in neonatal piglets and preterm infants. METHODS DSCFO uses two small laser diodes as focused-point and a tiny CMOS camera as a high-density two-dimensional detector to detect spontaneous spatial fluctuation of diffuse laser speckles for CBF measurement, and light intensity attenuations for cerebral oxygenation measurement. The DSCFO was first validated against the established diffuse correlation spectroscopy (DCS) in neonatal piglets and then utilized for continuous CBF and oxygenation monitoring in preterm infants during intermittent hypoxemia (IH) events. RESULTS Significant correlations between the DSCFO and DCS measurements of CBF variations in neonatal piglets were observed. IH events induced fluctuations in CBF, cerebral oxygenation, and peripheral cardiorespiratory vitals in preterm infants. However, no consistent correlation patterns were observed among peripheral and cerebral monitoring parameters. CONCLUSIONS This pilot study demonstrated the feasibility of DSCFO technology to serve as a low-cost wearable sensor for continuous monitoring of multiple cerebral hemodynamic parameters. The results suggested the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations. IMPACT The innovative DSCFO technology may serve as a low-cost wearable sensor for continuous bedside monitoring of multiple cerebral hemodynamic parameters in neonatal intensive care units. Concurrent DSCFO and DCS measurements of CBF variations in neonatal piglet models generated consistent results. No consistent correlation patterns were observed among peripheral and cerebral monitoring parameters in preterm neonates, suggesting the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations during IH events. Integrating and correlating multiple cerebral functional parameters with clinical outcomes may identify biomarkers for prediction and management of IH associated brain injury.
Collapse
Affiliation(s)
- Xuhui Liu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA
| | - Mehrana Mohtasebi
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA
| | - Pegah Safavi
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA
| | - Faraneh Fathi
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA
| | | | - Li Chen
- Biostatistics and Bioinformatics Shared Resource Facility, Markey Cancer Center, University of Kentucky, Lexington, KY, USA
| | - Jin Chen
- Department of Internal Medicine and Department of Computer Science, Institute for Biomedical Informatics, University of Kentucky, Lexington, KY, USA
| | - Henrietta S Bada
- Division of Neonatology, Department of Pediatrics, University of Kentucky, Lexington, KY, USA
| | - Lei Chen
- Department of Physiology and the Spinal Cord and Brain Injury Research Center, University of Kentucky, Lexington, KY, USA
| | - Elie G Abu Jawdeh
- Division of Neonatology, Department of Pediatrics, University of Kentucky, Lexington, KY, USA
| | - Guoqiang Yu
- Department of Biomedical Engineering, University of Kentucky, Lexington, KY, USA.
| |
Collapse
|
2
|
Holmes M, Aalto D, Cummine J. Opening the dialogue: A preliminary exploration of hair color, hair cleanliness, light, and motion effects on fNIRS signal quality. PLoS One 2024; 19:e0304356. [PMID: 38781258 PMCID: PMC11115287 DOI: 10.1371/journal.pone.0304356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2024] [Accepted: 05/12/2024] [Indexed: 05/25/2024] Open
Abstract
INTRODUCTION Functional near-infrared spectroscopy (fNIRS) is a promising tool for studying brain activity, offering advantages such as portability and affordability. However, challenges in data collection persist due to factors like participant physiology, environmental light, and gross-motor movements, with limited literature on their impact on fNIRS signal quality. This study addresses four potentially influential factors-hair color, hair cleanliness, environmental light, and gross-motor movements-on fNIRS signal quality. Our aim is to raise awareness and offer insights for future fNIRS research. METHODS Six participants (4 Females, 2 Males) took part in four different experiments investigating the effects of hair color, hair cleanliness, environmental light, and gross-motor movements on fNIRS signal quality. Participants in Experiment 1, categorized by hair color, completed a finger-tapping task in a between-subjects block design. Signal quality was compared between each hair color. Participants in Experiments 2 and 3 completed a finger-tapping task in a within-subjects block design, with signal quality being compared across hair cleanliness (i.e., five consecutive days without washing the hair) and environmental light (i.e., sunlight, artificial light, no light, etc.), respectively. Experiment 4 assessed three gross-motor movements (i.e., walking, turning and nodding the head) in a within-subjects block design. Motor movements were then compared to resting blocks. Signal quality was evaluated using Scalp Coupling Index (SCI) measurements. RESULTS Lighter hair produced better signals than dark hair, while the impact of environmental light remains uncertain. Hair cleanliness showed no significant effects, but gross motor movements notably reduced signal quality. CONCLUSION Our results suggest that hair color, environmental light, and gross-motor movements affect fNIRS signal quality while hair cleanliness does not. Nevertheless, future studies with larger sample sizes are warranted to fully understand these effects. To advance future research, comprehensive documentation of participant demographics and lab conditions, along with signal quality analyses, is essential.
Collapse
Affiliation(s)
- Mitchell Holmes
- Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, Alberta, Canada
| | - Daniel Aalto
- Faculty of Medicine and Dentistry, Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada
- Faculty of Rehabilitation Medicine, Department of Communication Sciences and Disorders, University of Alberta, Edmonton, Alberta, Canada
- Institute for Reconstructive Science in Medicine (iRSM), Misericordia Community Hospital, Edmonton, Alberta, Canada
| | - Jacqueline Cummine
- Faculty of Medicine and Dentistry, Neuroscience and Mental Health Institute, University of Alberta, Edmonton, Alberta, Canada
- Faculty of Rehabilitation Medicine, Department of Communication Sciences and Disorders, University of Alberta, Edmonton, Alberta, Canada
| |
Collapse
|
3
|
Perrey S, Quaresima V, Ferrari M. Muscle Oximetry in Sports Science: An Updated Systematic Review. Sports Med 2024; 54:975-996. [PMID: 38345731 PMCID: PMC11052892 DOI: 10.1007/s40279-023-01987-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/15/2023] [Indexed: 04/28/2024]
Abstract
BACKGROUND In the last 5 years since our last systematic review, a significant number of articles have been published on the technical aspects of muscle near-infrared spectroscopy (NIRS), the interpretation of the signals and the benefits of using the NIRS technique to measure the physiological status of muscles and to determine the workload of working muscles. OBJECTIVES Considering the consistent number of studies on the application of muscle oximetry in sports science published over the last 5 years, the objectives of this updated systematic review were to highlight the applications of muscle oximetry in the assessment of skeletal muscle oxidative performance in sports activities and to emphasize how this technology has been applied to exercise and training over the last 5 years. In addition, some recent instrumental developments will be briefly summarized. METHODS Preferred Reporting Items for Systematic Reviews guidelines were followed in a systematic fashion to search, appraise and synthesize existing literature on this topic. Electronic databases such as Scopus, MEDLINE/PubMed and SPORTDiscus were searched from March 2017 up to March 2023. Potential inclusions were screened against eligibility criteria relating to recreationally trained to elite athletes, with or without training programmes, who must have assessed physiological variables monitored by commercial oximeters or NIRS instrumentation. RESULTS Of the identified records, 191 studies regrouping 3435 participants, met the eligibility criteria. This systematic review highlighted a number of key findings in 37 domains of sport activities. Overall, NIRS information can be used as a meaningful marker of skeletal muscle oxidative capacity and can become one of the primary monitoring tools in practice in conjunction with, or in comparison with, heart rate or mechanical power indices in diverse exercise contexts and across different types of training and interventions. CONCLUSIONS Although the feasibility and success of the use of muscle oximetry in sports science is well documented, there is still a need for further instrumental development to overcome current instrumental limitations. Longitudinal studies are urgently needed to strengthen the benefits of using muscle oximetry in sports science.
Collapse
Affiliation(s)
- Stephane Perrey
- EuroMov Digital Health in Motion, University of Montpellier, IMT Mines Ales, Montpellier, France
| | - Valentina Quaresima
- Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy.
| | - Marco Ferrari
- Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| |
Collapse
|
4
|
Łabaj F, Kalwas J, Piramidowicz R. Design and development of a miniature mid-infrared linear variable filter based spectrometer for environmental sensing. OPTICS EXPRESS 2023; 31:37583-37596. [PMID: 38017885 DOI: 10.1364/oe.497564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 08/23/2023] [Indexed: 11/30/2023]
Abstract
Miniaturized, energy-efficient and application-specific spectral sensing systems promise to be a highly sought-after technology in the coming years, with potential applications in areas such as: distributed sensor systems, IoT devices, mobile autonomous platforms, and many others. We present in this work the design, construction and measurement results of a compact, mid-infrared spectrometer working in the 3 - 4 µm spectral region, attractive for applications requiring the identification of polymer materials. The spectrometer is based on linear-variable filters (LVF) combined with an uncooled HgCdTe linear-detector array (LDA). The design and architecture of the device is described and discussed in the context of miniaturization challenges and constraints. Measured spectra of thin polyimide and polystyrene foils are presented to prove the applicability of the developed device to polymer materials detection and identification.
Collapse
|
5
|
Amendola C, Buttafava M, Carteano T, Contini L, Cortese L, Durduran T, Frabasile L, Guadagno CN, Karadeinz U, Lacerenza M, Mesquida J, Parsa S, Re R, Sanoja Garcia D, Konugolu Venkata Sekar S, Spinelli L, Torricelli A, Tosi A, Weigel UM, Yaqub MA, Zanoletti M, Contini D. Assessment of power spectral density of microvascular hemodynamics in skeletal muscles at very low and low-frequency via near-infrared diffuse optical spectroscopies. BIOMEDICAL OPTICS EXPRESS 2023; 14:5994-6015. [PMID: 38021143 PMCID: PMC10659778 DOI: 10.1364/boe.502618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 10/10/2023] [Accepted: 10/16/2023] [Indexed: 12/01/2023]
Abstract
In this work, we used a hybrid time domain near-infrared spectroscopy (TD-NIRS) and diffuse correlation spectroscopy (DCS) device to retrieve hemoglobin and blood flow oscillations of skeletal muscle microvasculature. We focused on very low (VLF) and low-frequency (LF) oscillations (i.e., frequency lower than 0.145 Hz), that are related to myogenic, neurogenic and endothelial activities. We measured power spectral density (PSD) of blood flow and hemoglobin concentration in four muscles (thenar eminence, plantar fascia, sternocleidomastoid and forearm) of 14 healthy volunteers to highlight possible differences in microvascular hemodynamic oscillations. We observed larger PSDs for blood flow compared to hemoglobin concentration, in particular in case of distal muscles (i.e., thenar eminence and plantar fascia). Finally, we compared the PSDs measured on the thenar eminence of healthy subjects with the ones measured on a septic patient in the intensive care unit: lower power in the endothelial-dependent frequency band, and larger power in the myogenic ones were observed in the septic patient, in accordance with previous works based on laser doppler flowmetry.
Collapse
Affiliation(s)
| | | | | | | | - Lorenzo Cortese
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Turgut Durduran
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
- Institució Catalana de Recerca i Estudis Avançats (ICREA), Barcelona, Spain
| | | | - Claudia Nunzia Guadagno
- BioPixS Ltd – Biophotonics Standards, IPIC, Tyndall National Institute, Lee Maltings Complex, Cork, Ireland
| | - Umut Karadeinz
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | | | - Jaume Mesquida
- Critical Care Department, Parc Taulí Hospital Universitari. Institut D’Investigació i Innovació Parc Taulí I3PT, Sabadell, Spain
| | | | - Rebecca Re
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | | | | | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Alberto Tosi
- Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milan, Italy
| | - Udo M. Weigel
- HemoPhotonics S.L., Castelldefels, (Barcelona), Spain
| | - M. Atif Yaqub
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Marta Zanoletti
- ICFO - Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, Castelldefels (Barcelona), Spain
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
| |
Collapse
|
6
|
Liu X, Mohtasebi M, Safavi P, Fathi F, Haratbar SR, Chen L, Chen J, Bada HS, Chen L, Abu Jawdeh EG, Yu G. A Wearable Fiber-Free Optical Sensor for Continuous Monitoring of Neonatal Cerebral Blood Flow and Oxygenation. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2023:2023.09.21.23295914. [PMID: 37790418 PMCID: PMC10543216 DOI: 10.1101/2023.09.21.23295914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/05/2023]
Abstract
Impact The innovative DSCFO technology may serve as a low-cost wearable sensor for continuous bedside monitoring of multiple cerebral hemodynamic parameters in neonatal intensive care units.Concurrent DSCFO and DCS measurements of CBF variations in neonatal piglet models generated consistent results.No consistent correlation patterns were observed among peripheral and cerebral monitoring parameters in preterm neonates, suggesting the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations during IH events.Integrating and correlating multiple cerebral functional parameters with clinical outcomes may identify biomarkers for prediction and management of IH associated brain injury. Background Unstable cerebral hemodynamics places preterm infants at high risk of brain injury. We adapted an innovative, fiber-free, wearable diffuse speckle contrast flow-oximetry (DSCFO) device for continuous monitoring of both cerebral blood flow (CBF) and oxygenation in neonatal piglets and preterm infants. Methods DSCFO uses two small laser diodes as focused-point and a tiny CMOS camera as a high-density two-dimensional detector to detect spontaneous spatial fluctuation of diffuse laser speckles for CBF measurement, and light intensity attenuations for cerebral oxygenation measurement. The DSCFO was first validated against the established diffuse correlation spectroscopy (DCS) in neonatal piglets and then utilized for continuous CBF and oxygenation monitoring in preterm infants during intermittent hypoxemia (IH) events. Results Consistent results between the DSCFO and DCS measurements of CBF variations in neonatal piglets were observed. IH events induced fluctuations in CBF, cerebral oxygenation, and peripheral cardiorespiratory vitals in preterm infants. However, no consistent correlation patterns were observed among peripheral and cerebral monitoring parameters. Conclusions This pilot study demonstrated the feasibility of DSCFO technology to serve as a low-cost wearable sensor for continuous monitoring of multiple cerebral hemodynamic parameters. The results suggested the importance of multi-parameter measurements for understanding deep insights of peripheral and cerebral regulations.
Collapse
|
7
|
Yi L, Xie G, Li Z, Li X, Zhang Y, Wu K, Shao G, Lv B, Jing H, Zhang C, Liang W, Sun J, Hao Z, Liang J. Automatic depression diagnosis through hybrid EEG and near-infrared spectroscopy features using support vector machine. Front Neurosci 2023; 17:1205931. [PMID: 37694121 PMCID: PMC10483285 DOI: 10.3389/fnins.2023.1205931] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2023] [Accepted: 08/10/2023] [Indexed: 09/12/2023] Open
Abstract
Depression is a common mental disorder that seriously affects patients' social function and daily life. Its accurate diagnosis remains a big challenge in depression treatment. In this study, we used electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) and measured the whole brain EEG signals and forehead hemodynamic signals from 25 depression patients and 30 healthy subjects during the resting state. On one hand, we explored the EEG brain functional network properties, and found that the clustering coefficient and local efficiency of the delta and theta bands in patients were significantly higher than those in normal subjects. On the other hand, we extracted brain network properties, asymmetry, and brain oxygen entropy as alternative features, used a data-driven automated method to select features, and established a support vector machine model for automatic depression classification. The results showed the classification accuracy was 81.8% when using EEG features alone and increased to 92.7% when using hybrid EEG and fNIRS features. The brain network local efficiency in the delta band, hemispheric asymmetry in the theta band and brain oxygen sample entropy features differed significantly between the two groups (p < 0.05) and showed high depression distinguishing ability indicating that they may be effective biological markers for identifying depression. EEG, fNIRS and machine learning constitute an effective method for classifying depression at the individual level.
Collapse
Affiliation(s)
- Li Yi
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Guojun Xie
- Department of Psychiatry, The Third People’s Hospital of Foshan, Foshan, China
- Department of Psychiatry, The Third Affiliated Hospital of Foshan University, Foshan, China
| | - Zhihao Li
- School of Medicine, Foshan University, Foshan, China
| | - Xiaoling Li
- Department of Psychiatry, The Third People’s Hospital of Foshan, Foshan, China
- Department of Psychiatry, The Third Affiliated Hospital of Foshan University, Foshan, China
| | - Yizheng Zhang
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Kai Wu
- School of Biomedical Sciences and Engineering, South China University of Technology, Guangzhou, China
| | - Guangjian Shao
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Biliang Lv
- School of Medicine, Foshan University, Foshan, China
| | - Huan Jing
- Department of Psychiatry, The Third People’s Hospital of Foshan, Foshan, China
- Department of Psychiatry, The Third Affiliated Hospital of Foshan University, Foshan, China
| | - Chunguo Zhang
- Department of Psychiatry, The Third People’s Hospital of Foshan, Foshan, China
- Department of Psychiatry, The Third Affiliated Hospital of Foshan University, Foshan, China
| | - Wenting Liang
- Department of Psychiatry, The Third People’s Hospital of Foshan, Foshan, China
- Department of Psychiatry, The Third Affiliated Hospital of Foshan University, Foshan, China
| | - Jinyan Sun
- School of Medicine, Foshan University, Foshan, China
| | - Zhifeng Hao
- College of Science, Shantou University, Shantou, China
| | - Jiaquan Liang
- Department of Psychiatry, The Third People’s Hospital of Foshan, Foshan, China
- Department of Psychiatry, The Third Affiliated Hospital of Foshan University, Foshan, China
| |
Collapse
|
8
|
Lacerenza M, Frabasile L, Buttafava M, Spinelli L, Bassani E, Micheloni F, Amendola C, Torricelli A, Contini D. Motor cortex hemodynamic response to goal-oriented and non-goal-oriented tasks in healthy subjects. Front Neurosci 2023; 17:1202705. [PMID: 37539388 PMCID: PMC10394236 DOI: 10.3389/fnins.2023.1202705] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Accepted: 06/16/2023] [Indexed: 08/05/2023] Open
Abstract
Background Motor disorders are one of the world's major scourges, and neuromotor rehabilitation is paramount for prevention and monitoring plans. In this scenario, exercises and motor tasks to be performed by patients are crucial to follow and assess treatments' progression and efficacy. Nowadays, in clinical environments, quantitative assessment of motor cortex activities during task execution is rare, due to the bulkiness of instrumentation and the need for immobility during measurements [e.g., functional magnetic resonance imaging (MRI)]. Functional near-infrared spectroscopy (fNIRS) can contribute to a better understanding of how neuromotor processes work by measuring motor cortex activity non-invasively in freely moving subjects. Aim Exploit fNIRS to measure functional activation of the motor cortex area during arm-raising actions. Design All subjects performed three different upper limbs motor tasks: arm raising (non-goal-oriented), arm raising and grasping (goal oriented), and assisted arm raising (passive task). Each task was repeated ten times. The block design for each task was divided into 5 seconds of baseline, 5 seconds of activity, and 15 seconds of recovery. Population Sixteen healthy subjects (11 males and 5 females) with an average (+/- standard deviation) of 37.9 (+/- 13.0) years old. Methods Cerebral hemodynamic responses have been recorded in two locations, motor cortex (activation area) and prefrontal cortex (control location) exploiting commercial time-domain fNIRS devices. Haemodynamic signals were analyzed, separating the brain cortex hemodynamic response from extracerebral hemodynamic variations. Results The hemodynamic response was recorded in the cortical motor area for goal-oriented and not-goaloriented tasks, while no response was noticed in the control location (prefrontal cortex position). Conclusions This study provides a basis for canonical upper limb motor cortex activations that can be potentially compared to pathological cerebral responses in patients. It also highlights the potential use of TD-fNIRS to study goal-oriented versus non-goaloriented motor tasks. Impact: the findings of this study may have implications for clinical rehabilitation by providing a better understanding of the neural mechanisms underlying goal-oriented versus non-goal-oriented motor tasks. This may lead to more effective rehabilitation strategies for individuals with motor disorders and a more effective diagnosis of motor dysfunction supported by objective and quantitative neurophysiological readings.
Collapse
Affiliation(s)
- Michele Lacerenza
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- PIONIRS s.r.l., Milano, Italy
| | | | | | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Elisa Bassani
- Scuola Universitaria Professionale della Svizzera Italiana, Manno, Switzerland
- Centro Studi Riabilitazione Neurologica, Neuropsicologia e Neuropsicoterapia, Milano, Italy
| | - Francesco Micheloni
- Centro Studi Riabilitazione Neurologica, Neuropsicologia e Neuropsicoterapia, Milano, Italy
| | | | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| |
Collapse
|
9
|
Du J, Shi P, Fang F, Yu H. Cerebral cortical hemodynamic metrics to aid in assessing pain levels? A pilot study of functional near-infrared spectroscopy. Front Neurosci 2023; 17:1136820. [PMID: 37008231 PMCID: PMC10050350 DOI: 10.3389/fnins.2023.1136820] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 03/01/2023] [Indexed: 03/17/2023] Open
Abstract
IntroductionEstablishing an accurate way to quantify pain is one of the most formidable tasks in neuroscience and medical practice. Functional near-infrared spectroscopy (fNIRS) can be utilized to detect the brain’s reaction to pain. The study sought to assess the neural mechanisms of the wrist-ankle acupuncture transcutaneous electrical nerve stimulation analgesic bracelet (E-WAA) in providing pain relief and altering cerebral blood volume dynamics, and to ascertain the reliability of cortical activation patterns as a means of objectively measuring pain.MethodsThe participants (mean age 36.6 ± 7.2 years) with the cervical-shoulder syndrome (CSS) underwent pain testing prior to, 1 min following, and 30 min after the left point Jianyu treatment. The E-WAA was used to administer an electrical stimulation therapy that lasted for 5 min. A 24-channel fNIRS system was utilized to monitor brain oxyhemoglobin (HbO) levels, and changes in HbO concentrations, cortical activation areas, and subjective pain assessment scales were documented.ResultsWe discovered that HbO concentrations in the prefrontal cortex significantly increased when CSS patients were exposed to painful stimuli at the cerebral cortex level. The second pain test saw a considerable decrease in the average HbO change amount in the prefrontal cortex when E-WAA was applied, which in turn led to a reduction in the amount of activation and the size of the activated area in the cortex.DiscussionThis study revealed that the frontal polar (FP) and dorsolateral prefrontal cortex (DLPFC) were linked to the analgesic modulation activated by the E-WAA.
Collapse
Affiliation(s)
- Jiahao Du
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China
| | - Ping Shi
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China
- *Correspondence: Ping Shi,
| | - Fanfu Fang
- Department of Rehabilitation Medicine, Changhai Hospital, Naval Medical University, Shanghai, China
- Fanfu Fang,
| | - Hongliu Yu
- Institute of Rehabilitation Engineering and Technology, University of Shanghai for Science and Technology, Shanghai, China
| |
Collapse
|
10
|
Chen H, Liang J, Huang W, Yang A, Pang R, Zhao C, Wu K, Wang C, Yan K, Zhang Y, Lin S, Xie Y, Wu Y, Sun J. Age-related difference in muscle metabolism patterns during upper limb's encircling exercise: a near-infrared spectroscopy study. BIOMEDICAL OPTICS EXPRESS 2022; 13:4737-4751. [PMID: 36187255 PMCID: PMC9484442 DOI: 10.1364/boe.462551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/24/2022] [Accepted: 07/10/2022] [Indexed: 06/16/2023]
Abstract
Aging is usually accompanied by decrease in limb motor function and change in muscle metabolism patterns. However, few studies have investigated the aging effect on muscle hemodynamics of the upper extremity. This study aims to explore the aging effect on muscle metabolism patterns during upper limb's exercise. Twelve middle-aged and elderly subjects and 12 young subjects were recruited, and muscle oxygenation signals from these subjects' biceps brachii muscles were collected during active and passive upper limb's encircling exercise with near-infrared spectroscopy (NIRS). The old group showed stronger muscle hemodynamic metabolism than the young group. The multiscale fuzzy approximate entropy and multiscale transfer entropy analyses indicated higher complexity and stronger interlimb coupling of the muscle oxygenation signals for the old group. Based on the selected muscle metabolism features, the constructed support vector machine model showed a high accuracy rate for classifying the two groups of subjects: 91.6% for the passive mode and 87.5% for the active mode. Our results proved the specific muscle metabolism patterns in the upper limb's exercise for old subjects, promoting the understanding of the aging effect on muscle hemodynamics.
Collapse
Affiliation(s)
- Hucheng Chen
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
- Equal contribution
| | - Jianbin Liang
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
- Equal contribution
| | - Wenzhu Huang
- Fifth Affiliated Hospital of Foshan University, Foshan, China
| | - Anping Yang
- School of Medicine, Foshan University, Foshan, China
| | - Richong Pang
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Chaochao Zhao
- School of Medicine, Foshan University, Foshan, China
| | - Kai Wu
- School of Biomedical Sciences and Engineering, South China University of Technology, Guangzhou, China
| | - Chong Wang
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Kecheng Yan
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - YiZheng Zhang
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Shuoshu Lin
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Yuanrong Xie
- School of Mechatronic Engineering and Automation, Foshan University, Foshan, China
| | - Yuxiang Wu
- Department of Health and Physical Education, Jianghan University, Wuhan, China
| | - Jinyan Sun
- School of Medicine, Foshan University, Foshan, China
| |
Collapse
|
11
|
Ban HY, Barrett GM, Borisevich A, Chaturvedi A, Dahle JL, Dehghani H, Dubois J, Field RM, Gopalakrishnan V, Gundran A, Henninger M, Ho WC, Hughes HD, Jin R, Kates-Harbeck J, Landy T, Leggiero M, Lerner G, Aghajan ZM, Moon M, Olvera I, Park S, Patel MJ, Perdue KL, Siepser B, Sorgenfrei S, Sun N, Szczepanski V, Zhang M, Zhu Z. Kernel Flow: a high channel count scalable time-domain functional near-infrared spectroscopy system. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-210278SSR. [PMID: 35043610 PMCID: PMC8765296 DOI: 10.1117/1.jbo.27.7.074710] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Accepted: 12/23/2021] [Indexed: 05/26/2023]
Abstract
SIGNIFICANCE Time-domain functional near-infrared spectroscopy (TD-fNIRS) has been considered as the gold standard of noninvasive optical brain imaging devices. However, due to the high cost, complexity, and large form factor, it has not been as widely adopted as continuous wave NIRS systems. AIM Kernel Flow is a TD-fNIRS system that has been designed to break through these limitations by maintaining the performance of a research grade TD-fNIRS system while integrating all of the components into a small modular device. APPROACH The Kernel Flow modules are built around miniaturized laser drivers, custom integrated circuits, and specialized detectors. The modules can be assembled into a system with dense channel coverage over the entire head. RESULTS We show performance similar to benchtop systems with our miniaturized device as characterized by standardized tissue and optical phantom protocols for TD-fNIRS and human neuroscience results. CONCLUSIONS The miniaturized design of the Kernel Flow system allows for broader applications of TD-fNIRS.
Collapse
Affiliation(s)
- Han Y. Ban
- Kernel, Los Angeles, California, United States
| | | | | | | | | | | | | | | | | | | | | | | | | | - Rong Jin
- Kernel, Los Angeles, California, United States
| | | | - Thanh Landy
- Kernel, Los Angeles, California, United States
| | | | | | | | | | - Isai Olvera
- Kernel, Los Angeles, California, United States
| | | | | | | | | | | | - Nathan Sun
- Kernel, Los Angeles, California, United States
| | | | - Mary Zhang
- Kernel, Los Angeles, California, United States
| | - Zhenye Zhu
- Kernel, Los Angeles, California, United States
| |
Collapse
|
12
|
Sudakou A, Lange F, Isler H, Lanka P, Wojtkiewicz S, Sawosz P, Ostojic D, Wolf M, Pifferi A, Tachtsidis I, Liebert A, Gerega A. Time-domain NIRS system based on supercontinuum light source and multi-wavelength detection: validation for tissue oxygenation studies. BIOMEDICAL OPTICS EXPRESS 2021; 12:6629-6650. [PMID: 34745761 PMCID: PMC8548017 DOI: 10.1364/boe.431301] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/13/2021] [Revised: 08/06/2021] [Accepted: 09/07/2021] [Indexed: 05/15/2023]
Abstract
We present and validate a multi-wavelength time-domain near-infrared spectroscopy (TD-NIRS) system that avoids switching wavelengths and instead exploits the full capability of a supercontinuum light source by emitting and acquiring signals for the whole chosen range of wavelengths. The system was designed for muscle and brain oxygenation monitoring in a clinical environment. A pulsed supercontinuum laser emits broadband light and each of two detection modules acquires the distributions of times of flight of photons (DTOFs) for 16 spectral channels (used width 12.5 nm / channel), providing a total of 32 DTOFs at up to 3 Hz. Two emitting fibers and two detection fiber bundles allow simultaneous measurements at two positions on the tissue or at two source-detector separations. Three established protocols (BIP, MEDPHOT, and nEUROPt) were used to quantitatively assess the system's performance, including linearity, coupling, accuracy, and depth sensitivity. Measurements were performed on 32 homogeneous phantoms and two inhomogeneous phantoms (solid and liquid). Furthermore, measurements on two blood-lipid phantoms with a varied amount of blood and Intralipid provide the strongest validation for accurate tissue oximetry. The retrieved hemoglobin concentrations and oxygen saturation match well with the reference values that were obtained using a commercially available NIRS system (OxiplexTS) and a blood gas analyzer (ABL90 FLEX), except a discrepancy occurs for the lowest amount of Intralipid. In-vivo measurements on the forearm of three healthy volunteers during arterial (250 mmHg) and venous (60 mmHg) cuff occlusions provide an example of tissue monitoring during the expected hemodynamic changes that follow previously well-described physiologies. All results, including quantitative parameters, can be compared to other systems that report similar tests. Overall, the presented TD-NIRS system has an exemplary performance evaluated with state-of-the-art performance assessment methods.
Collapse
Affiliation(s)
- Aleh Sudakou
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| | - Frédéric Lange
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Helene Isler
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Pranav Lanka
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| | | | - Piotr Sawosz
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| | - Daniel Ostojic
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Martin Wolf
- Department of Neonatology, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | - Antonio Pifferi
- Dipartimento di Fisica, Politecnico di Milano, Milano, Italy
| | - Ilias Tachtsidis
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Adam Liebert
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| | - Anna Gerega
- Nalecz Institute of Biocybernetics and Biomedical Engineering, Warsaw, Poland
| |
Collapse
|
13
|
Hannah R, Aron AR. Towards real-world generalizability of a circuit for action-stopping. Nat Rev Neurosci 2021; 22:538-552. [PMID: 34326532 PMCID: PMC8972073 DOI: 10.1038/s41583-021-00485-1] [Citation(s) in RCA: 52] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/04/2021] [Indexed: 02/07/2023]
Abstract
Two decades of cross-species neuroscience research on rapid action-stopping in the laboratory has provided motivation for an underlying prefrontal-basal ganglia circuit. Here we provide an update of key studies from the past few years. We conclude that this basic neural circuit is on increasingly firm ground, and we move on to consider whether the action-stopping function implemented by this circuit applies beyond the simple laboratory stop signal task. We advance through a series of studies of increasing 'real-worldness', starting with laboratory tests of stopping of speech, gait and bodily functions, and then going beyond the laboratory to consider neural recordings and stimulation during moments of control presumably required in everyday activities such as walking and driving. We end by asking whether stopping research has clinical relevance, focusing on movement disorders such as stuttering, tics and freezing of gait. Overall, we conclude there are hints that the prefrontal-basal ganglia action-stopping circuit that is engaged by the basic stop signal task is recruited in myriad scenarios; however, truly proving this for real-world scenarios requires a new generation of studies that will need to overcome substantial technical and inferential challenges.
Collapse
Affiliation(s)
- Ricci Hannah
- Department of Psychology, University of California San Diego, San Diego, CA, USA.
| | - Adam R Aron
- Department of Psychology, University of California San Diego, San Diego, CA, USA
| |
Collapse
|
14
|
Amendola C, Lacerenza M, Pirovano I, Contini D, Spinelli L, Cubeddu R, Torricelli A, Re R. Optical characterization of 3D printed PLA and ABS filaments for diffuse optics applications. PLoS One 2021; 16:e0253181. [PMID: 34133454 PMCID: PMC8208549 DOI: 10.1371/journal.pone.0253181] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Accepted: 05/28/2021] [Indexed: 01/01/2023] Open
Abstract
The interest for Fused Deposition Modelling (FDM) in the field of Diffuse Optics (DO) is rapidly increasing. The most widespread FDM materials are polylactic acid (PLA) and acrylonitrile butadiene styrene (ABS), thanks to their low cost and easiness-to-print. This is why, in this study, 3D printed samples of PLA and ABS materials were optically characterized in the range from the UV up to the IR wavelengths, in order to test their possible employment for probe construction in DO applications. To this purpose, measurements with Near Infrared Spectroscopy and Diffuse Correlation Spectroscopy techniques were considered. The results obtained show how the material employed for probe construction can negatively affect the quality of DO measurements.
Collapse
Affiliation(s)
- Caterina Amendola
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- * E-mail:
| | | | | | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie (IFN), Consiglio Nazionale delle Ricerche, Milan, Italy
| | - Rinaldo Cubeddu
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie (IFN), Consiglio Nazionale delle Ricerche, Milan, Italy
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie (IFN), Consiglio Nazionale delle Ricerche, Milan, Italy
| | - Rebecca Re
- Dipartimento di Fisica, Politecnico di Milano, Milan, Italy
- Istituto di Fotonica e Nanotecnologie (IFN), Consiglio Nazionale delle Ricerche, Milan, Italy
| |
Collapse
|
15
|
von Lühmann A, Zheng Y, Ortega-Martinez A, Kiran S, Somers DC, Cronin-Golomb A, Awad LN, Ellis TD, Boas DA, Yücel MA. Towards Neuroscience of the Everyday World (NEW) using functional Near-Infrared Spectroscopy. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2021; 18:100272. [PMID: 33709044 PMCID: PMC7943029 DOI: 10.1016/j.cobme.2021.100272] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Functional Near-Infrared Spectroscopy (fNIRS) assesses human brain activity by noninvasively measuring changes of cerebral hemoglobin concentrations caused by modulation of neuronal activity. Recent progress in signal processing and advances in system design, such as miniaturization, wearability and system sensitivity, have strengthened fNIRS as a viable and cost-effective complement to functional Magnetic Resonance Imaging (fMRI), expanding the repertoire of experimental studies that can be performed by the neuroscience community. The availability of fNIRS and Electroencephalography (EEG) for routine, increasingly unconstrained, and mobile brain imaging is leading towards a new domain that we term "Neuroscience of the Everyday World" (NEW). In this light, we review recent advances in hardware, study design and signal processing, and discuss challenges and future directions towards achieving NEW.
Collapse
Affiliation(s)
- Alexander von Lühmann
- Neurophotonics Center, Biomedical Engineering, Boston University, Boston, MA 02215, USA
- NIRx Medical Technologies, Berlin 13355, Germany
| | - Yilei Zheng
- Neurophotonics Center, Biomedical Engineering, Boston University, Boston, MA 02215, USA
- State Key Laboratory of Virtual Reality Technology and Systems, Beihang University, Beijing 100191, China
| | | | - Swathi Kiran
- Department of Speech, Language, and Hearing, Boston University, Boston, MA 02215, USA
| | - David C. Somers
- Department of Psychological and Brain Sciences, Boston University, Boston, MA 02215, USA
| | - Alice Cronin-Golomb
- Department of Psychological and Brain Sciences, Boston University, Boston, MA 02215, USA
| | - Louis N. Awad
- College of Health and Rehabilitation Sciences, Sargent College, Boston University, Boston, MA 02215, USA
| | - Terry D. Ellis
- College of Health and Rehabilitation Sciences, Sargent College, Boston University, Boston, MA 02215, USA
| | - David A. Boas
- Neurophotonics Center, Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - Meryem A. Yücel
- Neurophotonics Center, Biomedical Engineering, Boston University, Boston, MA 02215, USA
| |
Collapse
|
16
|
Kim Y, Marone A, Tang W, Gartshteyn Y, Kim HK, Askanase AD, Kymissis I, Hielscher AH. Flexible optical imaging band system for the assessment of arthritis in patients with systemic lupus erythematosus. BIOMEDICAL OPTICS EXPRESS 2021; 12:1651-1665. [PMID: 33796379 PMCID: PMC7984785 DOI: 10.1364/boe.415575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 01/15/2021] [Accepted: 01/18/2021] [Indexed: 06/12/2023]
Abstract
We have developed a flexible optical imaging system (FOIS) to assess systemic lupus erythematosus (SLE) arthritis in the finger joints. While any part of the body can be affected, arthritis in the finger joints is one of the most common SLE manifestations. There is an unmet need for accurate, low-cost assessment of lupus arthritis that can be easily performed at every clinic visit. Current imaging methods are imprecise, expensive, and time consuming to allow for frequent monitoring. Our FOIS can be wrapped around joints, and multiple light sources and detectors gather reflected and transmitted light intensities. Using data from two SLE patients and two healthy volunteers, we demonstrate the potential of this FOIS for assessment of arthritis in SLE patients.
Collapse
Affiliation(s)
- Youngwan Kim
- Columbia University, Department of Electrical Engineering, 500 W. 120th Street, New York, NY 10027, USA
- New York University, Department of Biomedical Engineering, Brooklyn, NY 11201, USA
| | - Alessandro Marone
- New York University, Department of Biomedical Engineering, Brooklyn, NY 11201, USA
| | - Wei Tang
- Columbia University Irving Medical Center, Department of Medicine-Rheumatology, 650 W. 168th Street, New York, NY 10032, USA
| | - Yevgeniya Gartshteyn
- Columbia University Irving Medical Center, Department of Medicine-Rheumatology, 650 W. 168th Street, New York, NY 10032, USA
| | - Hyun K. Kim
- New York University, Department of Biomedical Engineering, Brooklyn, NY 11201, USA
- Columbia University Irving Medical Center, Department of Radiology, 650 W. 168th Street, New York, NY 10032, USA
| | - Anca D. Askanase
- Columbia University Irving Medical Center, Department of Medicine-Rheumatology, 650 W. 168th Street, New York, NY 10032, USA
| | - Ioannis Kymissis
- Columbia University, Department of Electrical Engineering, 500 W. 120th Street, New York, NY 10027, USA
| | - Andreas H. Hielscher
- New York University, Department of Biomedical Engineering, Brooklyn, NY 11201, USA
- Columbia University, Department of Biomedical Engineering, 500 W. 120th Street, New York, NY 10027, USA
| |
Collapse
|
17
|
Amendola C, Lacerenza M, Buttafava M, Tosi A, Spinelli L, Contini D, Torricelli A. A Compact Multi-Distance DCS and Time Domain NIRS Hybrid System for Hemodynamic and Metabolic Measurements. SENSORS 2021; 21:s21030870. [PMID: 33525488 PMCID: PMC7866011 DOI: 10.3390/s21030870] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/22/2021] [Accepted: 01/24/2021] [Indexed: 01/17/2023]
Abstract
In this work, we present a new multi-distance diffuse correlation spectroscopy (DCS) device integrated with a compact state-of-the-art time domain near infrared spectroscopy (TD-NIRS) device. The hybrid DCS and TD-NIRS system allows to retrieve information on blood flow, tissue oxygenation, and oxygen metabolic rate. The DCS device performances were estimated in terms of stability, repeatability, ability in retrieving variations of diffusion coefficient, influence of the tissue optical properties, effect of varying count rates and depth sensitivity. Crosstalk between DCS and TD-NIRS optical signals was also evaluated. Finally, in vivo experiments (venous and arterial cuff occlusions on the arm) were conducted to test the ability of the hybrid system in measuring blood flow variations.
Collapse
Affiliation(s)
- Caterina Amendola
- Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo da Vinci 32, 20133 Milan, Italy; (M.L.); (D.C.)
- Correspondence: (C.A.); (A.T.)
| | - Michele Lacerenza
- Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo da Vinci 32, 20133 Milan, Italy; (M.L.); (D.C.)
| | - Mauro Buttafava
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, via Ponzio 34/5, 20133 Milan, Italy; (M.B.); (A.T.)
| | - Alberto Tosi
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, via Ponzio 34/5, 20133 Milan, Italy; (M.B.); (A.T.)
| | - Lorenzo Spinelli
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, piazza Leonardo da Vinci 32, 20133 Milan, Italy;
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo da Vinci 32, 20133 Milan, Italy; (M.L.); (D.C.)
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, piazza Leonardo da Vinci 32, 20133 Milan, Italy; (M.L.); (D.C.)
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, piazza Leonardo da Vinci 32, 20133 Milan, Italy;
- Correspondence: (C.A.); (A.T.)
| |
Collapse
|
18
|
Lacerenza M, Spinelli L, Buttafava M, Dalla Mora A, Zappa F, Pifferi A, Tosi A, Cozzi B, Torricelli A, Contini D. Monitoring the motor cortex hemodynamic response function in freely moving walking subjects: a time-domain fNIRS pilot study. NEUROPHOTONICS 2021; 8:015006. [PMID: 33628861 PMCID: PMC7899043 DOI: 10.1117/1.nph.8.1.015006] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Accepted: 01/28/2021] [Indexed: 06/12/2023]
Abstract
Significance: This study is a preliminary step toward the identification of a noninvasive and reliable tool for monitoring the presence and progress of gaiting dysfunctions. Aim: We present the results of a pilot study for monitoring the motor cortex hemodynamic response function (HRF) in freely walking subjects, with time-domain functional near-infrared spectroscopy (TD fNIRS). Approach: A compact and wearable single-channel TD fNIRS oximeter was employed. The lower limb motor cortex area of three healthy subjects was monitored while performing two different freely moving gaiting tasks: forward and backward walking. Results: The time course of oxygenated and deoxygenated hemoglobin was measured during the different walking tasks. Brain motor cortex hemodynamic activations have been analyzed throughout an adaptive HRF fitting procedure, showing a greater involvement of motor area in the backward walking task. By comparison with the HRF obtained in a finger-tapping task performed in a still condition, we excluded any effect of motion artifacts in the gaiting tasks. Conclusions: For the first time to our knowledge, the hemodynamic motor cortex response was measured by TD fNIRS during natural, freely walking exercises. The cortical response during forward and backward walking shows differences, possibly related to the diverse involvement of the motor cortex in the two types of gaiting.
Collapse
Affiliation(s)
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Mauro Buttafava
- Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milano, Italy
| | | | - Franco Zappa
- Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milano, Italy
| | - Antonio Pifferi
- Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Alberto Tosi
- Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Milano, Italy
| | - Bruno Cozzi
- Università degli Studi di Padova, Dipartimento di Biomedicina Comparata e Alimentazione, Legnaro, Italy
| | - Alessandro Torricelli
- Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Milano, Italy
| | - Davide Contini
- Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
| |
Collapse
|
19
|
Liu X, Gu Y, Huang C, Zhao M, Cheng Y, Jawdeh EGA, Bada HS, Chen L, Yu G. Simultaneous measurements of tissue blood flow and oxygenation using a wearable fiber-free optical sensor. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-200314RR. [PMID: 33515216 PMCID: PMC7846117 DOI: 10.1117/1.jbo.26.1.012705] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Accepted: 01/12/2021] [Indexed: 05/08/2023]
Abstract
SIGNIFICANCE There is an essential need to develop wearable multimodality technologies that can continuously measure both blood flow and oxygenation in deep tissues to investigate and manage various vascular/cellular diseases. AIM To develop a wearable dual-wavelength diffuse speckle contrast flow oximetry (DSCFO) for simultaneous measurements of blood flow and oxygenation variations in deep tissues. APPROACH A wearable fiber-free DSCFO probe was fabricated using 3D printing to confine two small near-infrared laser diodes and a tiny CMOS camera in positions for DSCFO measurements. The spatial diffuse speckle contrast and light intensity measurements at the two different wavelengths enable quantification of tissue blood flow and oxygenation, respectively. The DSCFO was first calibrated using tissue phantoms and then tested in adult forearms during artery cuff occlusion. RESULTS Phantom tests determined the largest effective source-detector distance (15 mm) and optimal camera exposure time (10 ms) and verified the accuracy of DSCFO in measuring absorption coefficient variations. The DSCFO detected substantial changes in forearm blood flow and oxygenation resulting from the artery occlusion, which meet physiological expectations and are consistent with previous study results. CONCLUSIONS The wearable DSCFO may be used for continuous and simultaneous monitoring of blood flow and oxygenation variations in freely behaving subjects.
Collapse
Affiliation(s)
- Xuhui Liu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Yutong Gu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Chong Huang
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Mingjun Zhao
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Yanda Cheng
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Elie G. Abu Jawdeh
- University of Kentucky, Department of Pediatrics, College of Medicine, Lexington, Kentucky, United States
| | - Henrietta S. Bada
- University of Kentucky, Department of Pediatrics, College of Medicine, Lexington, Kentucky, United States
| | - Lei Chen
- University of Kentucky, Department of Physiology, Spinal Cord and Brain Injury Research Center, Lexington, Kentucky, United States
| | - Guoqiang Yu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
- Address all correspondence to Guoqiang Yu,
| |
Collapse
|
20
|
Lacerenza M, Buttafava M, Renna M, Mora AD, Spinelli L, Zappa F, Pifferi A, Torricelli A, Tosi A, Contini D. Wearable and wireless time-domain near-infrared spectroscopy system for brain and muscle hemodynamic monitoring. BIOMEDICAL OPTICS EXPRESS 2020; 11:5934-5949. [PMID: 33149997 PMCID: PMC7587270 DOI: 10.1364/boe.403327] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 09/09/2020] [Accepted: 09/11/2020] [Indexed: 05/04/2023]
Abstract
We present a wearable time-domain near infrared spectroscopy (TD-NIRS) system (two wavelengths, one detection channel), which fits in a backpack and performs real-time hemodynamic measurements on the brain and muscle tissues of freely moving subjects. It can provide concentration values of oxygenated hemoglobin (O2Hb), deoxygenated hemoglobin (HHb), total hemoglobin (tHb = O2Hb + HHb) and tissue oxygen saturation (StO2). The system is battery-operated and can be wirelessly controlled. By following established characterization protocols for performance assessment of diffuse optics instruments, we achieved results comparable with state-of-the-art research-grade TD-NIRS systems. We also performed in-vivo measurements such as finger tapping (motor cortex monitoring), breath holding (prefrontal cortex monitoring and forearm muscle monitoring), and outdoor bike riding (vastus lateralis muscle monitoring), in order to test the system capabilities in evaluating both muscle and brain hemodynamics.
Collapse
Affiliation(s)
| | - Mauro Buttafava
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy
| | - Marco Renna
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy
| | | | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, 20133 Milano, Italy
| | - Franco Zappa
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy
| | - Antonio Pifferi
- Dipartimento di Fisica, Politecnico di Milano, 20133 Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, 20133 Milano, Italy
| | - Alessandro Torricelli
- Dipartimento di Fisica, Politecnico di Milano, 20133 Milano, Italy
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, 20133 Milano, Italy
| | - Alberto Tosi
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, 20133 Milano, Italy
| |
Collapse
|