1
|
Liu H, Teng X, Yu S, Yang W, Kong T, Liu T. Recent Advances in Photoacoustic Imaging: Current Status and Future Perspectives. MICROMACHINES 2024; 15:1007. [PMID: 39203658 PMCID: PMC11356134 DOI: 10.3390/mi15081007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2024] [Revised: 07/30/2024] [Accepted: 08/02/2024] [Indexed: 09/03/2024]
Abstract
Photoacoustic imaging (PAI) is an emerging hybrid imaging modality that combines high-contrast optical imaging with high-spatial-resolution ultrasound imaging. PAI can provide a high spatial resolution and significant imaging depth by utilizing the distinctive spectroscopic characteristics of tissue, which gives it a wide variety of applications in biomedicine and preclinical research. In addition, it is non-ionizing and non-invasive, and photoacoustic (PA) signals are generated by a short-pulse laser under thermal expansion. In this study, we describe the basic principles of PAI, recent advances in research in human and animal tissues, and future perspectives.
Collapse
Affiliation(s)
- Huibin Liu
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai 264005, China; (H.L.); (X.T.); (S.Y.); (W.Y.)
| | - Xiangyu Teng
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai 264005, China; (H.L.); (X.T.); (S.Y.); (W.Y.)
| | - Shuxuan Yu
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai 264005, China; (H.L.); (X.T.); (S.Y.); (W.Y.)
| | - Wenguang Yang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai 264005, China; (H.L.); (X.T.); (S.Y.); (W.Y.)
| | - Tiantian Kong
- Shandong City Service Institute, Yantai 264005, China
| | - Tangying Liu
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai 264005, China; (H.L.); (X.T.); (S.Y.); (W.Y.)
| |
Collapse
|
2
|
Rodrigues J, Amin A, Chandra S, Mulla NJ, Nayak GS, Rai S, Ray S, Mahato KK. Machine Learning Enabled Photoacoustic Spectroscopy for Noninvasive Assessment of Breast Tumor Progression In Vivo: A Preclinical Study. ACS Sens 2024; 9:589-601. [PMID: 38288735 PMCID: PMC10897932 DOI: 10.1021/acssensors.3c01085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2023] [Revised: 11/25/2023] [Accepted: 01/17/2024] [Indexed: 02/24/2024]
Abstract
Breast cancer is a dreaded disease affecting women the most in cancer-related deaths over other cancers. However, early diagnosis of the disease can help increase survival rates. The existing breast cancer diagnosis tools do not support the early diagnosis of the disease. Therefore, there is a great need to develop early diagnostic tools for this cancer. Photoacoustic spectroscopy (PAS), being very sensitive to biochemical changes, can be relied upon for its application in detecting breast tumors in vivo. With this motivation, in the current study, an aseptic chamber integrated photoacoustic (PA) probe was designed and developed to monitor breast tumor progression in vivo, established in nude mice. The device served the dual purpose of transporting tumor-bearing animals to the laboratory from the animal house and performing PA experiments in the same chamber, maintaining sterility. In the current study, breast tumor was induced in the nude mice by MCF-7 cells injection and the corresponding PA spectra at different time points (day 0, 5, 10, 15, and 20) of tumor progression in vivo in the same animals. The recorded photoacoustic spectra were subsequently preprocessed, wavelet-transformed, and subjected to filter-based feature selection algorithm. The selected top 20 features, by minimum redundancy maximum relevance (mRMR) algorithm, were then used to build an input feature matrix for machine learning (ML)-based classification of the data. The performance of classification models demonstrated 100% specificity, whereas the sensitivity of 95, 100, 92.5, and 85% for the time points, day 5, 10, 15, and 20, respectively. These results suggest the potential of PA signal-based classification of breast tumor progression in a preclinical model. The PA signal contains information on the biochemical changes associated with disease progression, emphasizing its translational strength toward early disease diagnosis.
Collapse
Affiliation(s)
- Jackson Rodrigues
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - Ashwini Amin
- Department
of Computer Science and Engineering, Manipal
Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India
| | - Subhash Chandra
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - Nitufa J. Mulla
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - G. Subramanya Nayak
- Department
of Electronics and Communication, Manipal
Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, India
| | - Sharada Rai
- Department
of Pathology, Kasturba Medical College Mangalore,
Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| | - Satadru Ray
- Department
of Surgery, Kasturba Medical College, Manipal
Academy of Higher Education, Karnataka,Manipal 576104, India
| | - Krishna Kishore Mahato
- Department
of Biophysics, Manipal School of Life Sciences, Manipal Academy of Higher Education, Karnataka, Manipal 576104, India
| |
Collapse
|
3
|
Sanchez M, Gallego D, Lamela H. High current short pulse driver using a high power diode laser for optoacoustic biomedical imaging techniques. OPTICS EXPRESS 2022; 30:44954-44966. [PMID: 36522908 DOI: 10.1364/oe.476159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Accepted: 11/09/2022] [Indexed: 06/17/2023]
Abstract
Optoacoustic biomedical imaging combines the high spatial resolution of the ultrasound imaging with the specificity of the optical absorption spectroscopy techniques. It is being used in various scenarios such as anatomical, functional and molecular imaging. Typically light sources for this imaging technique is based on solid state lasers since they can produce high energy short optical pulses. However, they are bulky, expensive and the imaging speed is limited because their low pulse repetition rate. High power diode lasers (HPDLs) are a promising alternative for imaging small volume absorbers as they are compact, affordable and allow high repetition rates. However, HPDLs provide relative low peak optical power compared to solid state lasers. Therefore, imaging systems based on diode lasers require much longer pulse duration resulting in lower in-depth resolution and optoacoustic conversion efficiency. HPDLs need dedicated fast electronics to generate short optical pulses. In this work, we have designed, built and test a pulsed diode laser driver based on RF power MOSFETs, specifically considering the optimization of the current pulse in order to maximize the optical peak power, achieving current pulses of more than 900 A with a duration of 50 ns. We have studied the operation of a low cost HPDL out of the manufacturers datasheet ratings without noticeable degradation at high current (> 250 A) and short pulse duration (< 60 ns). We have obtained an optical peak power of 750 W and a energy per pulse of 31.2 µJ at 40 ns optical pulse duration. The optoacoustic images obtained in this operation regime shown a clear enhancement respect to the ones obtained in standard operation of the HPDL.
Collapse
|
4
|
Zhang Y, Yang S, Xia Z, Hou R, Xu B, Hou L, Marsh JH, Hou JJ, Sani SMR, Liu X, Xiong J. Co-optimization method to improve lateral resolution in photoacoustic computed tomography. BIOMEDICAL OPTICS EXPRESS 2022; 13:4621-4636. [PMID: 36187257 PMCID: PMC9484412 DOI: 10.1364/boe.469744] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2022] [Revised: 08/01/2022] [Accepted: 08/01/2022] [Indexed: 05/28/2023]
Abstract
In biomedical imaging, photoacoustic computed tomography (PACT) has recently gained increased interest as this imaging technique has good optical contrast and depth of acoustic penetration. However, a spinning blur will be introduced during the image reconstruction process due to the limited size of the ultrasonic transducers (UT) and a discontinuous measurement process. In this study, a damping UT and adaptive back-projection co-optimization (CODA) method is developed to improve the lateral spatial resolution of PACT. In our PACT system, a damping aperture UT controls the size of the receiving area, which suppresses image blur at the signal acquisition stage. Then, an innovative adaptive back-projection algorithm is developed, which corrects the undesirable artifacts. The proposed method was evaluated using agar phantom and ex-vivo experiments. The results show that the CODA method can effectively compensate for the spinning blur and eliminate unwanted artifacts in PACT. The proposed method can significantly improve the lateral spatial resolution and image quality of reconstructed images, making it more appealing for wider clinical applications of PACT as a novel, cost-effective modality.
Collapse
Affiliation(s)
- Yang Zhang
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Shufan Yang
- School of Computing, Edinburgh Napier University, Edinburgh, Scotland, EH10 5DT, UK
| | - Zhiying Xia
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Ruijie Hou
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Bin Xu
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
| | - Lianping Hou
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK
| | - John H. Marsh
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK
| | - Jamie Jiangmin Hou
- The Royal College of Surgeons of Edinburgh, Nicolson Street, Edinburgh, Scotland, EH8 9DW, UK
| | | | - Xuefeng Liu
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
- Equal Contribution
| | - Jichuan Xiong
- School of Electronic and Optical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
- Equal Contribution
| |
Collapse
|
5
|
Rajendran P, Pramanik M. High frame rate (∼3 Hz) circular photoacoustic tomography using single-element ultrasound transducer aided with deep learning. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:066005. [PMID: 36452448 PMCID: PMC9209813 DOI: 10.1117/1.jbo.27.6.066005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/27/2022] [Accepted: 06/01/2022] [Indexed: 05/29/2023]
Abstract
Significance In circular scanning photoacoustic tomography (PAT), it takes several minutes to generate an image of acceptable quality, especially with a single-element ultrasound transducer (UST). The imaging speed can be enhanced by faster scanning (with high repetition rate light sources) and using multiple-USTs. However, artifacts arising from the sparse signal acquisition and low signal-to-noise ratio at higher scanning speeds limit the imaging speed. Thus, there is a need to improve the imaging speed of the PAT systems without hampering the quality of the PAT image. Aim To improve the frame rate (or imaging speed) of the PAT system by using deep learning (DL). Approach For improving the frame rate (or imaging speed) of the PAT system, we propose a novel U-Net-based DL framework to reconstruct PAT images from fast scanning data. Results The efficiency of the network was evaluated on both single- and multiple-UST-based PAT systems. Both phantom and in vivo imaging demonstrate that the network can improve the imaging frame rate by approximately sixfold in single-UST-based PAT systems and by approximately twofold in multi-UST-based PAT systems. Conclusions We proposed an innovative method to improve the frame rate (or imaging speed) by using DL and with this method, the fastest frame rate of ∼ 3 Hz imaging is achieved without hampering the quality of the reconstructed image.
Collapse
Affiliation(s)
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| |
Collapse
|
6
|
Bayram F, Gajula D, Khan D, Uppalapati B, Azad S, Koley G. Voltage triggered near-infrared light modulation using VO 2 thin film. OPTICS EXPRESS 2021; 29:32124-32134. [PMID: 34615290 DOI: 10.1364/oe.432245] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 08/31/2021] [Indexed: 06/13/2023]
Abstract
Development of compact and fast modulators of infrared light has garnered strong research interests in recent years due to their potential applications in communication, imaging, and sensing. In this study, electric field induced fast modulation near-infrared light caused by phase change in VO2 thin films grown on GaN suspended membranes has been reported. It was observed that metal insulator transition caused by temperature change or application of electric field, using an interdigitated finger geometry, resulted in 7% and 14% reduction in transmitted light intensity at near-infrared wavelengths of 790 and 1550 nm, respectively. Near-infrared light modulation has been demonstrated with voltage pulse widths down to 300 µs at 25 V magnitude. Finite element simulations performed on the suspended membrane modulator indicate a combination of the Joule heating and electric field is responsible for the phase transition.
Collapse
|
7
|
Palma-Chavez J, Pfefer TJ, Agrawal A, Jokerst JV, Vogt WC. Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment. JOURNAL OF BIOMEDICAL OPTICS 2021; 26:JBO-210176VSSR. [PMID: 34510850 PMCID: PMC8434148 DOI: 10.1117/1.jbo.26.9.090901] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 08/17/2021] [Indexed: 05/06/2023]
Abstract
SIGNIFICANCE Photoacoustic imaging (PAI) is a powerful emerging technology with broad clinical applications, but consensus test methods are needed to standardize performance evaluation and accelerate translation. AIM To review consensus image quality test methods for mature imaging modalities [ultrasound, magnetic resonance imaging (MRI), x-ray CT, and x-ray mammography], identify best practices in phantom design and testing procedures, and compare against current practices in PAI phantom testing. APPROACH We reviewed scientific papers, international standards, clinical accreditation guidelines, and professional society recommendations describing medical image quality test methods. Observations are organized by image quality characteristics (IQCs), including spatial resolution, geometric accuracy, imaging depth, uniformity, sensitivity, low-contrast detectability, and artifacts. RESULTS Consensus documents typically prescribed phantom geometry and material property requirements, as well as specific data acquisition and analysis protocols to optimize test consistency and reproducibility. While these documents considered a wide array of IQCs, reported PAI phantom testing focused heavily on in-plane resolution, depth of visualization, and sensitivity. Understudied IQCs that merit further consideration include out-of-plane resolution, geometric accuracy, uniformity, low-contrast detectability, and co-registration accuracy. CONCLUSIONS Available medical image quality standards provide a blueprint for establishing consensus best practices for photoacoustic image quality assessment and thus hastening PAI technology advancement, translation, and clinical adoption.
Collapse
Affiliation(s)
- Jorge Palma-Chavez
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
| | - T. Joshua Pfefer
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, United States
| | - Anant Agrawal
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, United States
| | - Jesse V. Jokerst
- University of California San Diego, Department of NanoEngineering, La Jolla, California, United States
- University of California San Diego, Department of Radiology, La Jolla, California, United States
- University of California San Diego, Materials Science and Engineering Program, La Jolla, California, United States
| | - William C. Vogt
- Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, United States
| |
Collapse
|
8
|
Waterproof Galvanometer Scanner-Based Handheld Photoacoustic Microscopy Probe for Wide-Field Vasculature Imaging In Vivo. PHOTONICS 2021. [DOI: 10.3390/photonics8080305] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Photoacoustic imaging (PAI) is a hybrid non-invasive imaging technique used to merge high optical contrast and high acoustic resolution in deep tissue. PAI has been extensively developed by utilizing its advantages that include deep imaging depth, high resolution, and label-free imaging. As a representative implementation of PAI, photoacoustic microscopy (PAM) has been used in preclinical and clinical studies for its micron-scale spatial resolution capability with high optical absorption contrast. Several handheld and portable PAM systems have been developed that improve its applicability to several fields, making it versatile. In this study, we developed a laboratory-customized, two-axis, waterproof, galvanometer scanner-based handheld PAM (WP-GVS-HH-PAM), which provides an extended field of view (14.5 × 9 mm2) for wide-range imaging. The fully waterproof handheld probe enables free movement for imaging regardless of sample shape, and volume rate and scanning region are adjustable per experimental conditions. Results of WP-GVS-HH-PAM-based phantom and in vivo imaging of mouse tissues (ear, iris, and brain) confirm the feasibility and applicability of our system as an imaging modality for various biomedical applications.
Collapse
|
9
|
Responsive optical probes for deep-tissue imaging: Photoacoustics and second near-infrared fluorescence. Adv Drug Deliv Rev 2021; 173:141-163. [PMID: 33774116 DOI: 10.1016/j.addr.2021.03.008] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2020] [Revised: 01/23/2021] [Accepted: 03/11/2021] [Indexed: 02/08/2023]
Abstract
Optical imaging has played a vital role in development of biomedicine and image-guided theragnostic. Nevertheless, the clinical translation of optical molecular imaging for deep-tissue visualization is still limited by poor signal-to-background ratio and low penetration depth owing to light scattering and tissue autofluorescence. Hence, to facilitate precise diagnosis and accurate surgery excision in clinical practices, the responsive optical probes (ROPs) are broadly designed for specific reaction with biological analytes or disease biomarkers via chemical/physical interactions for photoacoustic and second near-infrared fluorescence (NIR-II, 900-1700 nm) fluorescence imaging. Herein, the recent advances in the development of ROPs including molecular design principles, activated mechanisms and treatment responses for photoacoustic and NIR-II fluorescence imaging are reviewed. Furthermore, the present challenges and future perspectives of ROPs for deep-tissue imaging are also discussed.
Collapse
|
10
|
Chandramoorthi S, Thittai AK. Extending Imaging Depth in PLD-Based Photoacoustic Imaging: Moving Beyond Averaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:549-557. [PMID: 32784132 DOI: 10.1109/tuffc.2020.3015130] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Pulsed laser diodes (PLDs) promise to be an attractive alternative to solid-state laser sources in photoacoustic tomography (PAT) due to their portability, high-pulse repetition frequency (PRF), and cost effectiveness. However, due to their lower energy per pulse, which, in turn, results in lower fluence required per photoacoustic signal generation, PLD-based photoacoustic systems generally have maximum imaging depth that is lower in comparison to solid-state lasers. Averaging of multiple frames is usually employed as a common practice in high PRF PLD systems to improve the signal-to-noise ratio of the PAT images. In this work, we demonstrate that by combining the recently described approach of subpitch translation on the receive-side ultrasound transducer alongside averaging of multiple frames, it is feasible to increase the depth sensitivity in a PLD-based PAT imaging system. Here, experiments on phantom containing diluted India ink targets were performed at two different laser energy level settings, that is, 21 and [Formula: see text]. Results obtained showed that the imaging depth improves by ~38.5% from 9.1 to 12.6 mm for 21- [Formula: see text] energy level setting and by ~33.3% from 10.8 to 14.4 mm for 27- [Formula: see text] energy level setting by using λ /4-pitch translation and average of 128 frames in comparison to λ -pitch data acquired with the average of 128 frames. However, the achievable frame rate is reduced by a factor of 2 and 4 for λ /2 and λ /4 subpitch translation, respectively.
Collapse
|
11
|
Simultaneous Dual-Modal Multispectral Photoacoustic and Ultrasound Macroscopy for Three-Dimensional Whole-Body Imaging of Small Animals. PHOTONICS 2021. [DOI: 10.3390/photonics8010013] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Photoacoustic imaging is a promising medical imaging technique that provides excellent function imaging of an underlying biological tissue or organ. However, it is limited in providing structural information compared to other imaging modalities, such as ultrasound imaging. Thus, to offer complete morphological details of biological tissues, photoacoustic imaging is typically integrated with ultrasound imaging. This dual-modal imaging technique is already implemented on commercial clinical ultrasound imaging platforms. However, commercial platforms suffer from limited elevation resolution compared to the lateral and axial resolution. We have successfully developed a dual-modal photoacoustic and ultrasound imaging to address these limitations, specifically targeting animal studies. The system can acquire whole-body images of mice in vivo and provide complementary structural and functional information of biological tissue information simultaneously. The color-coded depth information can be readily obtained in photoacoustic images using complementary information from ultrasound images. The system can be used for several biomedical applications, including drug delivery, biodistribution assessment, and agent testing.
Collapse
|
12
|
Das D, Sharma A, Rajendran P, Pramanik M. Another decade of photoacoustic imaging. Phys Med Biol 2020; 66. [PMID: 33361580 DOI: 10.1088/1361-6560/abd669] [Citation(s) in RCA: 57] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 12/23/2020] [Indexed: 01/09/2023]
Abstract
Photoacoustic imaging - a hybrid biomedical imaging modality finding its way to clinical practices. Although the photoacoustic phenomenon was known more than a century back, only in the last two decades it has been widely researched and used for biomedical imaging applications. In this review we focus on the development and progress of the technology in the last decade (2010-2020). From becoming more and more user friendly, cheaper in cost, portable in size, photoacoustic imaging promises a wide range of applications, if translated to clinic. The growth of photoacoustic community is steady, and with several new directions researchers are exploring, it is inevitable that photoacoustic imaging will one day establish itself as a regular imaging system in the clinical practices.
Collapse
Affiliation(s)
- Dhiman Das
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, SINGAPORE
| | - Arunima Sharma
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, SINGAPORE
| | - Praveenbalaji Rajendran
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, SINGAPORE
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 70 Nanyang Drive, N1.3-B2-11, Singapore, 637457, SINGAPORE
| |
Collapse
|
13
|
Kuniyil Ajith Singh M, Xia W. Portable and Affordable Light Source-Based Photoacoustic Tomography. SENSORS (BASEL, SWITZERLAND) 2020; 20:E6173. [PMID: 33138296 PMCID: PMC7663770 DOI: 10.3390/s20216173] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 10/27/2020] [Accepted: 10/28/2020] [Indexed: 12/27/2022]
Abstract
Photoacoustic imaging is a hybrid imaging modality that offers the advantages of optical (spectroscopic contrast) and ultrasound imaging (scalable spatial resolution and imaging depth). This promising modality has shown excellent potential in a wide range of preclinical and clinical imaging and sensing applications. Even though photoacoustic imaging technology has matured in research settings, its clinical translation is not happening at the expected pace. One of the main reasons for this is the requirement of bulky and expensive pulsed lasers for excitation. To accelerate the clinical translation of photoacoustic imaging and explore its potential in resource-limited settings, it is of paramount importance to develop portable and affordable light sources that can be used as the excitation light source. In this review, we focus on the following aspects: (1) the basic theory of photoacoustic imaging; (2) inexpensive light sources and different implementations; and (3) important preclinical and clinical applications, demonstrated using affordable light source-based photoacoustics. The main focus will be on laser diodes and light-emitting diodes as they have demonstrated promise in photoacoustic tomography-the key technological developments in these areas will be thoroughly reviewed. We believe that this review will be a useful opus for both the beginners and experts in the field of biomedical photoacoustic imaging.
Collapse
Affiliation(s)
- Mithun Kuniyil Ajith Singh
- Research and Business Development Division, CYBERDYNE INC., Stationsplein 45, A4.004, 3013 AK Rotterdam, The Netherlands;
| | - Wenfeng Xia
- School of Biomedical Engineering& Imaging Sciences, King’s College London, King’s Health Partners, St Thomas’ Hospital, London SE1 7EH, UK
| |
Collapse
|
14
|
Zhan Y, Singh Rathore A, Milione G, Wang Y, Zheng W, Xu W, Xia J. 3D finger vein biometric authentication with photoacoustic tomography. APPLIED OPTICS 2020; 59:8751-8758. [PMID: 33104557 DOI: 10.1364/ao.400550] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Accepted: 08/24/2020] [Indexed: 06/11/2023]
Abstract
Biometric authentication is the recognition of human identity via unique anatomical features. The development of novel methods parallels widespread application by consumer devices, law enforcement, and access control. In particular, methods based on finger veins, as compared to face and fingerprints, obviate privacy concerns and degradation due to wear, age, and obscuration. However, they are two-dimensional (2D) and are fundamentally limited by conventional imaging and tissue-light scattering. In this work, for the first time, to the best of our knowledge, we demonstrate a method of three-dimensional (3D) finger vein biometric authentication based on photoacoustic tomography. Using a compact photoacoustic tomography setup and a novel recognition algorithm, the advantages of 3D are demonstrated via biometric authentication of index finger vessels with false acceptance, false rejection, and equal error rates <1.23%, <9.27%, and <0.13%, respectively, when comparing one finger, a false acceptance rateimprovement>10× when comparing multiple fingers, and <0.7% when rotating fingers ±30.
Collapse
|
15
|
Nguyen HNY, Steenbergen W. Three-dimensional view of out-of-plane artifacts in photoacoustic imaging using a laser-integrated linear-transducer-array probe. PHOTOACOUSTICS 2020; 19:100176. [PMID: 32257797 PMCID: PMC7096763 DOI: 10.1016/j.pacs.2020.100176] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Revised: 03/09/2020] [Accepted: 03/10/2020] [Indexed: 05/08/2023]
Abstract
Research on photoacoustic imaging (PAI) using a handheld integrated photoacoustic probe has been a recent focus of clinical translation of this imaging technique. One of the remaining challenges is the occurrence of out-of-plane artifacts (OPAs) in such a probe. Previously, we proposed a method to identify and remove OPAs by axially displacing the transducer array. Here we show that besides the benefit of removing OPAs from the imaging plane, the proposed method can provide a three-dimensional (3D) view of the OPAs. In this work, we present a 3D reconstruction method using axial transducer array displacement. By axially displacing the transducer array, out-of-plane absorbers can be three-dimensionally visualized at an elevation distance of up to the acquired imaging depth. Additionally, OPAs in the in-plane image are significantly reduced. We experimentally demonstrate the method with phantom and in vivo experiments using an integrated PAI probe. We also compare the method with elevational transducer array displacement and take into account the sensitivity of the transducer array in the 3D reconstruction.
Collapse
|
16
|
Rajendran P, Sahu S, Dienzo RA, Pramanik M. In vivo detection of venous sinus distension due to intracranial hypotension in small animal using pulsed-laser-diode photoacoustic tomography. JOURNAL OF BIOPHOTONICS 2020; 13:e201960162. [PMID: 32030895 DOI: 10.1002/jbio.201960162] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2019] [Revised: 12/18/2019] [Accepted: 02/01/2020] [Indexed: 05/24/2023]
Abstract
Intracranial hypotension (IH) is a pathophysiological condition of reduced intracranial pressure caused by low cerebrospinal fluid (CSF) volume due to dural injuries from lumbar puncture, surgery, or trauma. Understanding the prognosis of IH in small animal models is important to gain insights on the complications associated with it such as orthostatic headache, cerebral venous thrombosis, coma, and so forth. Photoacoustic tomography (PAT) offers a novel and cost-effective way to perceive and detect IH in small animal models. In this study, a pulsed laser diode (PLD)-based PAT imaging system was used to examine the changes in the venous sinuses of the rat brain due to IH, induced through CSF extraction. After the CSF extraction, an increase in the sagittal sinus area by ~30% and width by 40% ± 5% was observed. These results provide supportive evidence that the PLD-PAT can be employed for detecting changes in sagittal sinus due to IH in rat model.
Collapse
Affiliation(s)
- Praveenbalaji Rajendran
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang drive, Singapore, Singapore
| | - Samiran Sahu
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang drive, Singapore, Singapore
| | - Rhonnie Austria Dienzo
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang drive, Singapore, Singapore
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang drive, Singapore, Singapore
| |
Collapse
|
17
|
Sharma A, Ishak N, Swee-Hin T, Pramanik M. High resolution, label-free photoacoustic imaging of live chicken embryo developing in bioengineered eggshell. JOURNAL OF BIOPHOTONICS 2020; 13:e201960108. [PMID: 31908159 DOI: 10.1002/jbio.201960108] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2019] [Revised: 12/19/2019] [Accepted: 12/23/2019] [Indexed: 05/09/2023]
Abstract
Chicken embryos have been proven to be an attractive vertebrate model for biomedical research. They have helped in making significant contributions for advancements in various fields like developmental biology, cancer research and cardiovascular studies. However, a non-invasive, label-free method of imaging live chicken embryo at high resolution still needs to be developed and optimized. In this work, we have shown the potential of photoacoustic tomography (PAT) for imaging live chicken embryos cultured in bioengineered eggshells. Laser pulses at wavelengths of 532 and 740 nm were used for attaining cross-sectional images of chicken embryos at different developmental stages. Cross-sections along different depths were imaged to gain knowledge of the relative depth of different vessels and organs. Due to high optical absorption of vasculature and embryonic eye, images with good optical contrast could be acquired using this method. We have thus reported a label-free method of performing cross-sectional imaging of chicken embryos at high resolution demonstrating the capacity of PAT as a promising tool for avian embryo imaging.
Collapse
Affiliation(s)
- Arunima Sharma
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore
| | - Noreen Ishak
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore
- Institute of Molecular and Cell Biology, Agency for Science, Technology, and Research, Singapore, Singapore
| | - Teoh Swee-Hin
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, Singapore
| |
Collapse
|
18
|
Cheng P, Pu K. Activatable Phototheranostic Materials for Imaging-Guided Cancer Therapy. ACS APPLIED MATERIALS & INTERFACES 2020; 12:5286-5299. [PMID: 31730329 DOI: 10.1021/acsami.9b15064] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Cancer theranostics, which combines diagnostic and therapeutic effects into one entity, holds promise in precision medicine. Conventional theranostic agents possess always-on imaging signals and cytotoxic effects and thus often encounter poor selectivity or specificity in cancer treatment. To tackle this issue, activatable phototheranostic materials (PMs) have been developed to simultaneously and specifically turn on their diagnostic signals (fluorescence/self-luminescence/photoacoustic signals) and photothermal/photodynamic effects in response to cancer hallmarks. This Review summarizes the recent progress in the design, synthesis and proof-of-concept applications of activatable PMs. The molecular engineering strategy to increase tumor accumulation and enhance treatment efficacy are highlighted. Current challenges and future perspectives in this emerging field are also discussed.
Collapse
Affiliation(s)
- Penghui Cheng
- School of Chemical and Biomedical Engineering , Nanyang Technological University , 70 Nanyang Drive , 637457 Singapore
| | - Kanyi Pu
- School of Chemical and Biomedical Engineering , Nanyang Technological University , 70 Nanyang Drive , 637457 Singapore
| |
Collapse
|
19
|
Liu S, Tang K, Feng X, Jin H, Gao F, Zheng Y. Toward Wearable Healthcare: A Miniaturized 3D Imager With Coherent Frequency-Domain Photoacoustics. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2019; 13:1417-1424. [PMID: 31502987 DOI: 10.1109/tbcas.2019.2940243] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Medical monitoring is undergoing a translation from the hospital-based system to the personalized home-based system. With the aim of wearable application of photoacoustic technique, we propose a miniaturized photoacoustic 3D imager for superficial medical imaging. By employing the compact continuous-wave laser diode based optical irradiation and an ultrathin 2D matrix array based photoacoustic detection in the coherent frequency domain, a wearable imaging probe with a size of about 80 × 25 × 24 mm3 and a weight of 21 g is developed. At the backend, an FPGA controlled Howland current source drives the laser diodes to excite linear frequency modulated optical irradiation. Recorded by a portable multichannel data acquisition system, the generated photoacoustic responses are firstly compressed with the coherent frequency domain photoacoustic method and then extrapolated in the wavenumber-frequency domain for fast image reconstruction. With three-wavelength (450 nm, 638 nm, and 808 nm) laser irradiation, photoacoustic imaging can be operated multispectrally, endowing the developed imager with functional imaging capability in 3D space. With the imager worn on the human forearm, hemoglobin oxygen saturation level in superficial arm vasculature can be long-term monitored with high stability. When the imager is applied for imaging in a relatively large area (e.g., early melanoma detection in the human breast), flexible scanning in a handheld manner can be performed. This work opens the application potential of photoacoustic technique in a broad range of areas, including personalized healthcare, home health monitoring, and long-term physiologic monitoring.
Collapse
|
20
|
Development of a Stationary 3D Photoacoustic Imaging System Using Sparse Single-Element Transducers: Phantom Study. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9214505] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Photoacoustic imaging (PAI) is an emerging label-free and non-invasive modality for imaging biological tissues. PAI has been implemented in different configurations, one of which is photoacoustic computed tomography (PACT) with a potential wide range of applications, including brain and breast imaging. Hemispherical Array PACT (HA-PACT) is a variation of PACT that has solved the limited detection-view problem. Here, we designed an HA-PACT system consisting of 50 single element transducers. For implementation, we initially performed a simulation study, with parameters close to those in practice, to determine the relationship between the number of transducers and the quality of the reconstructed image. We then used the greatest number of transducers possible on the hemisphere and imaged copper wire phantoms coated with a light absorbing material to evaluate the performance of the system. Several practical issues such as light illumination, arrangement of the transducers, and an image reconstruction algorithm have been comprehensively studied.
Collapse
|
21
|
Vu T, Razansky D, Yao J. Listening to tissues with new light: recent technological advances in photoacoustic imaging. JOURNAL OF OPTICS (2010) 2019; 21:10.1088/2040-8986/ab3b1a. [PMID: 32051756 PMCID: PMC7015182 DOI: 10.1088/2040-8986/ab3b1a] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Photoacoustic tomography (PAT), or optoacoustic tomography, has achieved remarkable progress in the past decade, benefiting from the joint developments in optics, acoustics, chemistry, computing and mathematics. Unlike pure optical or ultrasound imaging, PAT can provide unique optical absorption contrast as well as widely scalable spatial resolution, penetration depth and imaging speed. Moreover, PAT has inherent sensitivity to tissue's functional, molecular, and metabolic state. With these merits, PAT has been applied in a wide range of life science disciplines, and has enabled biomedical research unattainable by other imaging methods. This Review article aims at introducing state-of-the-art PAT technologies and their representative applications. The focus is on recent technological breakthroughs in structural, functional, molecular PAT, including super-resolution imaging, real-time small-animal whole-body imaging, and high-sensitivity functional/molecular imaging. We also discuss the remaining challenges in PAT and envisioned opportunities.
Collapse
Affiliation(s)
- Tri Vu
- Photoacoustic Imaging Lab, Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Daniel Razansky
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Switzerland
- Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Junjie Yao
- Photoacoustic Imaging Lab, Department of Biomedical Engineering, Duke University, Durham, NC, USA
| |
Collapse
|
22
|
Fatima A, Kratkiewicz K, Manwar R, Zafar M, Zhang R, Huang B, Dadashzadeh N, Xia J, Avanaki K(M. Review of cost reduction methods in photoacoustic computed tomography. PHOTOACOUSTICS 2019; 15:100137. [PMID: 31428558 PMCID: PMC6693691 DOI: 10.1016/j.pacs.2019.100137] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2018] [Revised: 05/11/2019] [Accepted: 06/13/2019] [Indexed: 05/18/2023]
Abstract
Photoacoustic Computed Tomography (PACT) is a major configuration of photoacoustic imaging, a hybrid noninvasive modality for both functional and molecular imaging. PACT has rapidly gained importance in the field of biomedical imaging due to superior performance as compared to conventional optical imaging counterparts. However, the overall cost of developing a PACT system is one of the challenges towards clinical translation of this novel technique. The cost of a typical commercial PACT system originates from optical source, ultrasound detector, and data acquisition unit. With growing applications of photoacoustic imaging, there is a tremendous demand towards reducing its cost. In this review article, we have discussed various approaches to reduce the overall cost of a PACT system, and provided a cost estimation to build a low-cost PACT system.
Collapse
Affiliation(s)
- Afreen Fatima
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
- Department of Electrical & Computer Engineering, Wayne State University, Detroit, MI, USA
| | - Karl Kratkiewicz
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | - Rayyan Manwar
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | - Mohsin Zafar
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
| | | | - Bin Huang
- 3339 Northwest Ave, Bellingham, WA, USA
| | | | - Jun Xia
- Department of Biomedical Engineering, The State University of New York, Buffalo, NY, USA
| | - Kamran (Mohammad) Avanaki
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
- Department of Neurology, Wayne State University School of Medicine, Detroit, MI, USA
- Molecular Imaging Program, Barbara Ann Karmanos Cancer Institute, Wayne State University, Detroit, MI, USA
| |
Collapse
|
23
|
Liu S, Feng X, Jin H, Zhang R, Luo Y, Zheng Z, Gao F, Zheng Y. Handheld Photoacoustic Imager for Theranostics in 3D. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:2037-2046. [PMID: 30802853 DOI: 10.1109/tmi.2019.2900656] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
A handheld approach to 3D photoacoustic imaging is essential in clinical applications. To this end, we develop a 3D handheld photoacoustic imager for dynamic (temporally and spatially) volumetric visualization. In this 3D imager, the optically transmitting part and the acoustically receiving part are integrated into a single handheld probe with a compact size about 160 mm ×64 mm ×40 mm. Besides, a dedicated imaging reconstruction algorithm for the heterogeneous medium is developed based on the phase-shift migration method in the frequency domain, which deals well with the stratified condition in the designed system. Dynamic 3D imaging supporting flexible handheld operation is demonstrated with needle biopsy and in vitro temperature measurement for photothermal therapy. The development of such a 3D handheld photoacoustic system paves the way for compact and handheld-operating implementations, and its further clinical exploration is promising.
Collapse
|
24
|
Erfanzadeh M, Zhu Q. Photoacoustic imaging with low-cost sources; A review. PHOTOACOUSTICS 2019; 14:1-11. [PMID: 30923674 PMCID: PMC6423351 DOI: 10.1016/j.pacs.2019.01.004] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2018] [Revised: 12/28/2018] [Accepted: 01/24/2019] [Indexed: 05/04/2023]
Abstract
Benefitting from advantages of optical and ultrasound imaging, photoacoustic imaging (PAI) has demonstrated potentials in a wide range of medical applications. In order to facilitate clinical applications of PAI and encourage its application in low-resource settings, research on low-cost photoacoustic imaging with inexpensive optical sources has gained attention. Here, we review the advances made in photoacoustic imaging with low-cost sources.
Collapse
Affiliation(s)
- Mohsen Erfanzadeh
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Quing Zhu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63130, USA
- Department of Radiology, Washington University School of Medicine, St. Louis, MO 63110, USA
| |
Collapse
|
25
|
Zhong H, Zhang J, Duan T, Lan H, Zhou M, Gao F. Enabling both time-domain and frequency-domain photoacoustic imaging by a fingertip laser diode system. OPTICS LETTERS 2019; 44:1988-1991. [PMID: 30985792 DOI: 10.1364/ol.44.001988] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Photoacoustic imaging has attracted increasing research interest in recent years, due to its unique merit of combining light and sound. Enabling deep tissue imaging with high ultrasound spatial resolution and optical absorption contrast, photoacoustic imaging has been applied in various application scenarios including anatomical, functional and molecular imaging. However, the bulky and expensive laser source is one of the key bottlenecks that needs to be addressed for further compact system development. A photoacoustic imaging system based on a low-cost laser diode (LD) is one of the promising solutions. In this paper, we report a custom-made fingertip laser diode system enabling both pulsed and continuous modulation modes with shortest pulse-width of 40 ns, largest driving current of 13 A, and highest modulation frequency of 3 MHz, which is suitable for both time and frequency domain photoacoustic imaging. To the best of our knowledge, this may be the most compact laser source reported for photoacoustic imaging enabling both two modulation modes. Owing to its super-compact size, the proposed LD system could pave the pathway to a low-cost photoacoustic sensing and imaging device, even wearable photoacoustic biomedical sensors.
Collapse
|
26
|
Cherkashin MN, Brenner C, Hofmann MR. Transducer-matched multipulse excitation for signal-to-noise ratio improvement in diode laser-based photoacoustic systems. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-8. [PMID: 30968647 PMCID: PMC6990056 DOI: 10.1117/1.jbo.24.4.046001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Accepted: 03/19/2019] [Indexed: 05/25/2023]
Abstract
We analyze transducer-matched multipulse excitation as a method for improving of the signal-to-noise ratio (SNR) for diode laser-based photoacoustic systems. We discuss the principle of the technique, its advantages, and potential drawbacks and perform measurements to analyze the obtainable SNR increase. We show in experiment and computationally that a lower boundary estimate of 1.2 to 1.8 fold SNR improvement can be provided using transducer-matched pulse bursts, depending on the transducer and particular arrangement. Finally, we analyze implications that the transducer resonance effects may have on the recently introduced advanced photoacoustic techniques. The findings are of immediate interest to modalities utilizing dense pulse sequences and systems possessing limited pulse energy. In particular, transducer-matched multipulse excitation may be beneficial for diode-based photoacoustic systems operated with transducers in the range of 1 to 5 MHz since the required hardware is readily available.
Collapse
Affiliation(s)
- Maxim N. Cherkashin
- Ruhr University Bochum, Photonics and Terahertz Technology, Faculty of Electrical Engineering and Information Technology, Bochum, Germany
| | - Carsten Brenner
- Ruhr University Bochum, Photonics and Terahertz Technology, Faculty of Electrical Engineering and Information Technology, Bochum, Germany
| | - Martin R. Hofmann
- Ruhr University Bochum, Photonics and Terahertz Technology, Faculty of Electrical Engineering and Information Technology, Bochum, Germany
| |
Collapse
|
27
|
Upputuri PK, Pramanik M. Photoacoustic imaging in the second near-infrared window: a review. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-20. [PMID: 30968648 PMCID: PMC6990072 DOI: 10.1117/1.jbo.24.4.040901] [Citation(s) in RCA: 96] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 03/18/2019] [Indexed: 05/04/2023]
Abstract
Photoacoustic (PA) imaging is an emerging medical imaging modality that combines optical excitation and ultrasound detection. Because ultrasound scatters much less than light in biological tissues, PA generates high-resolution images at centimeters depth. In recent years, wavelengths in the second near-infrared (NIR-II) window (1000 to 1700 nm) have been increasingly explored due to its potential for preclinical and clinical applications. In contrast to the conventional PA imaging in the visible (400 to 700 nm) and the first NIR-I (700 to 1000 nm) window, PA imaging in the NIR-II window offers numerous advantages, including high spatial resolution, deeper penetration depth, reduced optical absorption, and tissue scattering. Moreover, the second window allows a fivefold higher light excitation energy density compared to the visible window for enhancing the imaging depth significantly. We highlight the importance of the second window for PA imaging and discuss the various NIR-II PA imaging systems and contrast agents with strong absorption in the NIR-II spectral region. Numerous applications of NIR-II PA imaging, including whole-body animal imaging and human imaging, are also discussed.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| |
Collapse
|
28
|
A Pseudo-Dynamic Delay Calculation Using Optimal Zone Segmentation for Ultra-Compact Ultrasound Imaging Systems. ELECTRONICS 2019. [DOI: 10.3390/electronics8020242] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The implementation of dynamic delay calculations (DDCs) is challenging for ultra-compact ultrasound imaging due to the enormous computation and power consumption requirements. Here, we present an efficient pseudo-DDC method based on optimal zone segmentation (PDC-Optimal), which significantly decreases these requirements relative to an unconstrained DDC method: reductions in flip-flops of 84.35% and in look-up tables of 94.19%, respectively. The reductions lead to an up to 94.53% lower dynamic power consumption and provide image quality comparable to the unconstrained DDC method. The proposed PDC-Optimal method also provides adaptive flexibility between beamforming accuracy and battery life using the delay error allowance, a user-definable parameter. A conventional pseudo-DDC method using uniform zone segmentation (PDC-Conv) presented substantial image degradation in the near imaging field when the same number of zone segments was used. Therefore, the PDC-Optimal method provides an efficient yet flexible DDC solution to improve the experiences for ultra-compact ultrasound imaging system users.
Collapse
|
29
|
Development of Low-Cost Fast Photoacoustic Computed Tomography: System Characterization and Phantom Study. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9030374] [Citation(s) in RCA: 37] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
A low-cost Photoacoustic Computed Tomography (PACT) system consisting of 16 single-element transducers has been developed. Our design proposes a fast rotating mechanism of 360o rotation around the imaging target, generating comparable images to those produced by large-number-element (e.g., 512, 1024, etc.) ring-array PACT systems. The 2D images with a temporal resolution of 1.5 s and a spatial resolution of 240 µm were achieved. The performance of the proposed system was evaluated by imaging complex phantom. The purpose of the proposed development is to provide researchers a low-cost alternative 2D photoacoustic computed tomography system with comparable resolution to the current high performance expensive ring-array PACT systems.
Collapse
|
30
|
Kalva SK, Upputuri PK, Pramanik M. High-speed, low-cost, pulsed-laser-diode-based second-generation desktop photoacoustic tomography system. OPTICS LETTERS 2019; 44:81-84. [PMID: 30645563 DOI: 10.1364/ol.44.000081] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Accepted: 11/24/2018] [Indexed: 05/18/2023]
Abstract
Bulky, expensive Nd:YAG lasers are used in conventional photoacoustic tomography (PAT) systems, making them difficult to translate into clinics. Moreover, real-time imaging is not feasible when a single-element ultrasound transducer is used with these low-pulse-repetition-rate lasers (10-100 Hz). Low-cost pulsed laser diodes (PLDs) can be used instead for photoacoustic imaging due to their high-pulse-repetition rates and compact size. Together with acoustic-reflector-based multiple single-element ultrasound transducers, a portable desktop PAT system was developed. This second-generation PLD-based PAT achieved 0.5 s cross-sectional imaging time with high spatial resolution of ∼165 μm and an imaging depth of 3 cm. The performance of this system was characterized using phantom and in vivo studies. Dynamic in vivo imaging was also demonstrated by monitoring the fast uptake and clearance of indocyanine green in small animal (rat) brain vasculature.
Collapse
|
31
|
Cherkashin MN, Brenner C, Hofmann MR. High-resolution 3D light fluence mapping for heterogeneous scattering media by localized sampling. APPLIED OPTICS 2018; 57:10441-10448. [PMID: 30645387 DOI: 10.1364/ao.57.010441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2018] [Accepted: 11/13/2018] [Indexed: 06/09/2023]
Abstract
We demonstrate an innovative concept for three-dimensional optical fluence mapping in heterogeneous highly scattering media as, e.g., biomedical tissues. We propose to use the relative light extinction analysis principle together with a miniaturized collection fiber in a direct fluence measurement setup as a method to obtain the spatially resolved light intensity distribution under transversally inhomogeneous light propagation conditions and provide local characterization of the transport medium. System performance is validated in two extreme conditions: an optically thin scattering medium and an absorption-dominated light transport. Both extremes demonstrate good agreement to theoretical expectations. Finally, we successfully prove the ability of the system to deliver high-resolution fluence maps through a model study of the light distribution induced in a scattering medium by a vertical diode laser stack with individual bars pitched only 500 μm apart.
Collapse
|
32
|
Miao Q, Pu K. Organic Semiconducting Agents for Deep-Tissue Molecular Imaging: Second Near-Infrared Fluorescence, Self-Luminescence, and Photoacoustics. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2018; 30:e1801778. [PMID: 30058244 DOI: 10.1002/adma.201801778] [Citation(s) in RCA: 358] [Impact Index Per Article: 59.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 05/17/2018] [Indexed: 05/05/2023]
Abstract
Optical imaging has played a pivotal role in biology and medicine, but it faces challenges of relatively low tissue penetration and poor signal-to-background ratio due to light scattering and tissue autofluorescence. To overcome these issues, second near-infrared fluorescence, self-luminescence, and photoacoustic imaging have recently emerged, which utilize an optical region with reduced light-tissue interactions, eliminate real-time light excitation, and detect acoustic signals with negligible attenuation, respectively. Because there are only a few endogenous molecules absorbing or emitting above the visible region, development of contrast agents is essential for those deep-tissue optical imaging modalities. Organic semiconducting agents with π-conjugated frameworks can be synthesized to meet different optical imaging requirements due to their easy chemical modification and legible structure-property relation. Herein, the deep-tissue optical imaging applications of organic semiconducting agents including small-molecule agents and nanoparticle derivatives are summarized. In particular, the molecular engineering and nanoformulation approaches to further improve the tissue penetration and detection sensitivity of these optical imaging modalities are highlighted. Finally, current challenges and potential opportunities in this emerging subfield of biomedical imaging are discussed.
Collapse
Affiliation(s)
- Qingqing Miao
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, 637457, Singapore
| | - Kanyi Pu
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore, 637457, Singapore
| |
Collapse
|
33
|
Stephanian B, Graham MT, Hou H, Lediju Bell MA. Additive noise models for photoacoustic spatial coherence theory. BIOMEDICAL OPTICS EXPRESS 2018; 9:5566-5582. [PMID: 30460147 PMCID: PMC6238926 DOI: 10.1364/boe.9.005566] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Revised: 09/09/2018] [Accepted: 10/01/2018] [Indexed: 05/16/2023]
Abstract
Directly displaying the spatial coherence of photoacoustic signals (i.e., coherence-based photoacoustic imaging) remarkably improves image contrast, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and imaging depth when compared to conventional amplitude-based reconstruction techniques (e.g., backprojection, delay-and-sum beamforming, and Fourier-based reconstruction). We recently developed photoacoustic-specific theory to describe the spatial coherence process as a function of the element spacing on a receive acoustic aperture to enable photoacoustic image optimization without requiring experiments. However, this theory lacked noise models, which contributed to significant departures in coherence measurements when compared to experimental data, particularly at higher values of element separation. In this paper, we develop and implement two models based on experimental observations of noise in photoacoustic spatial coherence measurements to improve our existing spatial coherence theory. These models were derived to describe the effects of incident fluence variations, low-energy light sources (e.g., pulsed laser diodes and light-emitting diodes), averaging multiple signals from low-energy light sources, and imaging with light sources that are > 5mm from photoacoustic targets. Results qualitatively match experimental coherence functions and provide similar contrast, SNR, and CNR to experimental SLSC images. In particular, the added noise affects image quality metrics by introducing large variations in target contrast and significantly reducing target CNR and SNR when compared to minimal-noise cases. These results provide insight into additional requirements for optimization of coherence-based photoacoustic image quality.
Collapse
Affiliation(s)
- Brooke Stephanian
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD,
USA
| | - Michelle T. Graham
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD,
USA
| | - Huayu Hou
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD,
USA
| | - Muyinatu A. Lediju Bell
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD,
USA
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD,
USA
| |
Collapse
|
34
|
Tang Y, Liu W, Li Y, Zhou Q, Yao J. Concurrent photoacoustic and ultrasound microscopy with a coaxial dual-element ultrasonic transducer. Vis Comput Ind Biomed Art 2018; 1:3. [PMID: 32240396 PMCID: PMC7098394 DOI: 10.1186/s42492-018-0003-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 06/25/2018] [Indexed: 11/20/2022] Open
Abstract
Simultaneous photoacoustic and ultrasound (PAUS) imaging has attracted increasing attention in biomedical research to probe the optical and mechanical properties of tissue. However, the resolution for majority of the existing PAUS systems is on the order of 1 mm as the majority are designed for clinical use with low-frequency US detection. Here we developed a concurrent PAUS microscopy that consists of optical-resolution photoacoustic microscopy (OR-PAM) and high-frequency US pulse-echo imaging. This dual-modality system utilizes a novel coaxial dual-element ultrasonic transducer (DE-UST) and provides anatomical and functional information with complementary contrast mechanisms, achieving a spatial resolution of 7 μm for PA imaging and 106 μm for US imaging. We performed phantom studies to validate the system’s performance. The vasculature of a mouse’s hind paw was imaged to demonstrate the potential of this hybrid system for biomedical applications.
Collapse
Affiliation(s)
- Yuqi Tang
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Wei Liu
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Yang Li
- Department of Ophthalmology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA
| | - Qifa Zhou
- Department of Ophthalmology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA.
| |
Collapse
|
35
|
Schellenberg MW, Hunt HK. Hand-held optoacoustic imaging: A review. PHOTOACOUSTICS 2018; 11:14-27. [PMID: 30073147 PMCID: PMC6068331 DOI: 10.1016/j.pacs.2018.07.001] [Citation(s) in RCA: 80] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2018] [Revised: 06/26/2018] [Accepted: 07/01/2018] [Indexed: 05/03/2023]
Abstract
Optoacoustic imaging is a medical imaging modality that uses optical excitation and acoustic detection to generate images of tissue structures based up optical absorption within a tissue sample. This imaging modality has been widely explored as a tool for a number of clinical applications, including cancer diagnosis and wound healing tracking. Recently, the optoacoustic imaging community has published a number of reports of hand-held optoacoustic imaging devices and platforms; these hand-held configurations improve the modality's potential for commercial clinical implementation. Here, we review recent advancements in hand-held optoacoustic imaging platforms and methods, including recent pre-clinical applications, and we present an overview of the remaining limitations in optoacoustic imaging that must be addressed to increase the translation of the modality into commercial and clinical use.
Collapse
Affiliation(s)
- Mason W. Schellenberg
- Department of Bioengineering, University of Missouri, 1406 E Rollin St., Columbia 65211, MO, USA
| | - Heather K. Hunt
- Department of Bioengineering, University of Missouri, 1406 E Rollin St., Columbia 65211, MO, USA
- Department of Dermatology, University of Missouri, 7 Hospital Dr., Columbia 65211, MO, USA
| |
Collapse
|
36
|
Upputuri PK, Yang C, Huang S, Wang K, Wang M, Pramanik M. Contrast-enhanced photoacoustic imaging in the second near-infrared window using semiconducting polymer nanoparticles. JOURNAL OF BIOMEDICAL OPTICS 2018; 24:1-7. [PMID: 30120826 PMCID: PMC6975224 DOI: 10.1117/1.jbo.24.3.031002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 05/21/2018] [Indexed: 05/05/2023]
Abstract
Photoacoustic imaging (PAI) is a fast growing deep-tissue imaging modality. However, light scattering and absorption in biological tissues limit imaging depth. Short near-infrared wavelengths (650 to 950 nm) are widely used for PAI. Using longer near-infrared wavelengths reduces scattering. We demonstrate deep-tissue contrast-enhanced in vivo photoacoustic imaging at a wavelength of 1064 nm. An ultranarrow bandgap semiconducting polymer poly (thienoisoindigo-alt-diketopyrrolopyrrole) (denoted as PIGD) is designed and demonstrated for imaging at 1064 nm. By embedding colloidal nanoparticles (NPs) of PIGD in chicken-breast tissue, an imaging depth of ∼5 cm is achieved. Intravenous injection of PIGD NPs in living rats showed brain vascular images with ∼2 times higher contrast compared with the brain vascular images without any contrast agent. Thus, PIGD NPs as an NIR-II contrast agent opens new opportunities for both preclinical and clinical imaging of deep tissues with enhanced contrast.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Cangjie Yang
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Shuo Huang
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Kai Wang
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Mingfeng Wang
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| |
Collapse
|
37
|
Review of Low-Cost Photoacoustic Sensing and Imaging Based on Laser Diode and Light-Emitting Diode. SENSORS 2018; 18:s18072264. [PMID: 30011842 PMCID: PMC6069016 DOI: 10.3390/s18072264] [Citation(s) in RCA: 52] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 06/23/2018] [Accepted: 06/25/2018] [Indexed: 01/16/2023]
Abstract
Photoacoustic tomography (PAT), a promising medical imaging method that combines optical and ultrasound techniques, has been developing for decades mostly in preclinical application. A recent trend is to utilize the economical laser source to develop a low-cost sensing and imaging system, which aims at an affordable solution in clinical application. These low-cost laser sources have different modulation modes such as pulsed modulation, continuous modulation and coded modulation to generate different profiles of PA signals in photoacoustic (PA) imaging. In this paper, we review the recent development of the photoacoustic sensing and imaging based on the economical laser sources such as laser diode (LD) and light-emitting diode (LED) in different kinds of modulation types, and discuss several representative methods to improve the performance of such imaging systems based on low-cost laser sources. Finally, some perspectives regarding the future development of portable PAT systems are discussed, followed by the conclusion.
Collapse
|
38
|
Zhu Y, Xu G, Yuan J, Jo J, Gandikota G, Demirci H, Agano T, Sato N, Shigeta Y, Wang X. Light Emitting Diodes based Photoacoustic Imaging and Potential Clinical Applications. Sci Rep 2018; 8:9885. [PMID: 29959412 PMCID: PMC6026116 DOI: 10.1038/s41598-018-28131-4] [Citation(s) in RCA: 68] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Accepted: 06/13/2018] [Indexed: 01/25/2023] Open
Abstract
Using low cost and small size light emitting diodes (LED) as the alternative illumination source for photoacoustic (PA) imaging has many advantages, and can largely benefit the clinical translation of the emerging PA imaging technology. Here, we present our development of LED-based PA imaging integrated with B-mode ultrasound. To overcome the challenge of achieving sufficient signal-to-noise ratio by the LED light that is orders of magnitude weaker than lasers, extensive signal averaging over hundreds of pulses is performed. Facilitated by the fast response of the LED and the high-speed driving as well as the high pulse repetition rate up to 16 kHz, B-mode PA images superimposed on gray-scale ultrasound of a biological sample can be achieved in real-time with frame rate up to 500 Hz. The LED-based PA imaging could be a promising tool for several clinical applications, such as assessment of peripheral microvascular function and dynamic changes, diagnosis of inflammatory arthritis, and detection of head and neck cancer.
Collapse
Affiliation(s)
- Yunhao Zhu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, 48109, USA.,Department of Electronic Science and Engineering, Nanjing University, Nanjing, Jiangsu, 21000, China
| | - Guan Xu
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, 48109, USA
| | - Jie Yuan
- Department of Electronic Science and Engineering, Nanjing University, Nanjing, Jiangsu, 21000, China.
| | - Janggun Jo
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, 48109, USA
| | - Girish Gandikota
- Department of Radiology, University of Michigan, Ann Arbor, Michigan, 48109, USA
| | - Hakan Demirci
- Kellogg Eye Center, University of Michigan, Ann Arbor, Michigan, 48109, USA
| | | | - Naoto Sato
- PreXion Corporation, Tokyo, 1010041, Japan
| | | | - Xueding Wang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, 48109, USA.
| |
Collapse
|
39
|
Mohammadi-Nejad AR, Mahmoudzadeh M, Hassanpour MS, Wallois F, Muzik O, Papadelis C, Hansen A, Soltanian-Zadeh H, Gelovani J, Nasiriavanaki M. Neonatal brain resting-state functional connectivity imaging modalities. PHOTOACOUSTICS 2018; 10:1-19. [PMID: 29511627 PMCID: PMC5832677 DOI: 10.1016/j.pacs.2018.01.003] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 01/12/2018] [Accepted: 01/27/2018] [Indexed: 05/12/2023]
Abstract
Infancy is the most critical period in human brain development. Studies demonstrate that subtle brain abnormalities during this state of life may greatly affect the developmental processes of the newborn infants. One of the rapidly developing methods for early characterization of abnormal brain development is functional connectivity of the brain at rest. While the majority of resting-state studies have been conducted using magnetic resonance imaging (MRI), there is clear evidence that resting-state functional connectivity (rs-FC) can also be evaluated using other imaging modalities. The aim of this review is to compare the advantages and limitations of different modalities used for the mapping of infants' brain functional connectivity at rest. In addition, we introduce photoacoustic tomography, a novel functional neuroimaging modality, as a complementary modality for functional mapping of infants' brain.
Collapse
Affiliation(s)
- Ali-Reza Mohammadi-Nejad
- CIPCE, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
- Departments of Radiology and Research Administration, Henry Ford Health System, Detroit, MI, USA
| | - Mahdi Mahmoudzadeh
- INSERM, U1105, Université de Picardie, CURS, F80036, Amiens, France
- INSERM U1105, Exploration Fonctionnelles du Système Nerveux Pédiatrique, South University Hospital, F80054, Amiens Cedex, France
| | | | - Fabrice Wallois
- INSERM, U1105, Université de Picardie, CURS, F80036, Amiens, France
- INSERM U1105, Exploration Fonctionnelles du Système Nerveux Pédiatrique, South University Hospital, F80054, Amiens Cedex, France
| | - Otto Muzik
- Department of Pediatrics, Wayne State University School of Medicine, Detroit, MI, USA
- Department of Radiology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Christos Papadelis
- Boston Children’s Hospital, Department of Medicine, Harvard Medical School, Boston, MA, USA
| | - Anne Hansen
- Boston Children’s Hospital, Department of Medicine, Harvard Medical School, Boston, MA, USA
| | - Hamid Soltanian-Zadeh
- CIPCE, School of Electrical and Computer Engineering, College of Engineering, University of Tehran, Tehran, Iran
- Departments of Radiology and Research Administration, Henry Ford Health System, Detroit, MI, USA
- Department of Radiology, Wayne State University School of Medicine, Detroit, MI, USA
| | - Juri Gelovani
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
- Molecular Imaging Program, Barbara Ann Karmanos Cancer Institute, Wayne State University, Detroit, MI, USA
| | - Mohammadreza Nasiriavanaki
- Department of Biomedical Engineering, Wayne State University, Detroit, MI, USA
- Department of Neurology, Wayne State University School of Medicine, Detroit, MI, USA
- Molecular Imaging Program, Barbara Ann Karmanos Cancer Institute, Wayne State University, Detroit, MI, USA
| |
Collapse
|
40
|
Upputuri PK, Pramanik M. Fast photoacoustic imaging systems using pulsed laser diodes: a review. Biomed Eng Lett 2018; 8:167-181. [PMID: 30603201 PMCID: PMC6208528 DOI: 10.1007/s13534-018-0060-9] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2018] [Revised: 02/21/2018] [Accepted: 02/26/2018] [Indexed: 12/15/2022] Open
Abstract
Photoacoustic imaging (PAI) is a newly emerging imaging modality for preclinical and clinical applications. The conventional PAI systems use Q-switched Nd:YAG/OPO (Optical Parametric Oscillator) nanosecond lasers as excitation sources. Such lasers are expensive, bulky, and imaging speed is limited because of low pulse repetition rate. In recent years, the semiconductor laser technology has advanced to generate high-repetitions rate near-infrared pulsed lasers diodes (PLDs) which are reliable, less-expensive, hand-held, and light-weight, about 200 g. In this article, we review the development and demonstration of PLD based PAI systems for preclinical and clinical applications reported in recent years.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, Singapore, 637459 Singapore
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, 62 Nanyang Drive, Singapore, 637459 Singapore
| |
Collapse
|
41
|
Kalva SK, Hui ZZ, Pramanik M. Calibrating reconstruction radius in a multi single-element ultrasound-transducer-based photoacoustic computed tomography system. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2018; 35:764-771. [PMID: 29726481 DOI: 10.1364/josaa.35.000764] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 03/22/2018] [Indexed: 05/21/2023]
Abstract
In a circular scanning photoacoustic computed tomography (PAT/PACT) system, a single-element ultrasound transducer (SUT) (rotates in full 360° around the sample) or a full-ring array transducer is used to acquire the photoacoustic (PA) data from the target object. SUT takes several minutes to acquire the PA data, whereas the full-ring array transducer takes only few seconds. Hence, for real-time imaging, full-ring circular array transducers are preferred. However, these are custom built, very expensive, and not available readily on the market, whereas SUTs are cheap and easily available. Thus, PACT systems can be made cost effective by using SUTs. To improve the data acquisition speed, multiple SUTs can be employed at the same time. This will reduce the acquisition time by N-fold if N numbers of SUTs are used, each rotating 360/N degrees. Experimentally, all SUTs cannot be placed exactly at the same distance from the scanning center. Hence, the acquired PA data from each transducer need to be reconstructed with their corresponding radii in a delay-and-sum reconstruction algorithm. This requires the exact location of each SUT from the scanning center. Here, we propose a calibration method to find out the distance from the scanning center at which each SUT acquires the PA data. Three numerical phantoms were used to show the efficacy of the proposed method, and later it was validated with experimental data (point source phantom).
Collapse
|
42
|
Stylogiannis A, Prade L, Buehler A, Aguirre J, Sergiadis G, Ntziachristos V. Continuous wave laser diodes enable fast optoacoustic imaging. PHOTOACOUSTICS 2018; 9:31-38. [PMID: 29387537 PMCID: PMC5772504 DOI: 10.1016/j.pacs.2017.12.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Revised: 11/22/2017] [Accepted: 12/14/2017] [Indexed: 05/18/2023]
Abstract
Pulsed laser diodes may offer a smaller, less expensive alternative to conventional optoacoustic laser sources; however they do not provide pulse rates faster than a few tens of kHz and emit at wavelengths only within the near-infrared region. We investigated whether continuous wave (CW) laser diodes, which are available in visible and near-infrared regions, can be good optoacoustic light sources when overdriven with a peak current >40-fold higher than the CW absolute maximum. We found that overdriven CW diodes provided ∼10 ns pulses of ∼200 nJ/pulse and repetition rates higher than 600 kHz without being damaged, outperforming many pulsed laser diodes. Using this system, we obtained images of phantoms and mouse ear and human arm in vivo, confirming their use in optoacoustic imaging and sensing.
Collapse
Key Words
- CNR, contrast to background ration
- COD, catastrophic optical damage
- CW, continuous wave
- Current drivers
- DAQ, data acquisition card
- FWHM, full width at half maximum
- Light sources
- Light-emitting diodes
- MIP, maximum intensity projection
- NIR, near-infrared
- Near-infrared
- OPO, optical parametric oscillator
- PLD, pulsed laser diode
- Photoacoustic
- SNR, signal-to-noise ratio
- TTL, transistor-transistor-logic
- UST, ultrasound transducer
- VIS, visible
- Visible
Collapse
Affiliation(s)
- Antonios Stylogiannis
- Institute of Biological and Medical Imaging, Technische Universität München, Munich, Germany and Helmholtz Zentrum München, Neuherberg, Germany
| | - Ludwig Prade
- Institute of Biological and Medical Imaging, Technische Universität München, Munich, Germany and Helmholtz Zentrum München, Neuherberg, Germany
| | - Andreas Buehler
- Institute of Biological and Medical Imaging, Technische Universität München, Munich, Germany and Helmholtz Zentrum München, Neuherberg, Germany
| | - Juan Aguirre
- Institute of Biological and Medical Imaging, Technische Universität München, Munich, Germany and Helmholtz Zentrum München, Neuherberg, Germany
| | - George Sergiadis
- Institute of Biological and Medical Imaging, Technische Universität München, Munich, Germany and Helmholtz Zentrum München, Neuherberg, Germany
- Department for Electrical and Computer Engineering, Aristotle University, 54124 Thessaloniki, Greece
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Technische Universität München, Munich, Germany and Helmholtz Zentrum München, Neuherberg, Germany
- Corresponding author.
| |
Collapse
|
43
|
Hariri A, Lemaster J, Wang J, Jeevarathinam AS, Chao DL, Jokerst JV. The characterization of an economic and portable LED-based photoacoustic imaging system to facilitate molecular imaging. PHOTOACOUSTICS 2018; 9:10-20. [PMID: 29234601 PMCID: PMC5723278 DOI: 10.1016/j.pacs.2017.11.001] [Citation(s) in RCA: 92] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/27/2017] [Revised: 11/06/2017] [Accepted: 11/19/2017] [Indexed: 05/04/2023]
Abstract
Photoacoustic imaging (PAI) is a non-invasive, high-resolution hybrid imaging modality that combines optical excitation and ultrasound detection. PAI can image endogenous chromophores (melanin, hemoglobin, etc.) and exogenous contrast agents in different medical applications. However, most current equipment uses sophisticated and complicated OPO lasers with tuning and stability features inconsistent with broad clinical deployment. As the number of applications of PAI in medicine increases, there is an urgent need to make the imaging equipment more compact, portable, and affordable. Here, portable light emitting diode - based photoacoustic imaging (PLED-PAI) was introduced and characterized in terms of system specifications, light source characterizations, photoacoustic spatial/temporal resolution, and penetration. The system uses two LED arrays attached to the sides of a conventional ultrasound transducer. The LED pulse repetition rate is tunable between 1 K Hz, 2 K Hz, 3 K Hz, and 4 K Hz. The axial resolution was 0.268 mm, and the lateral resolution was between 0.55 and 0.59 mm. The system could detect optical absorber (pencil lead) at a depth of 3.2 cm and the detection limits of indocyanine green (ICG) and methylene blue (MB) were 9 μM and 0.78 mM. In vivo imaging of labeled human mesenchymal stem cells was achieved to confirm compatibility with small animal imaging. The characterization we report here may have value to other groups evaluating commercially available photoacoustic imaging equipment.
Collapse
Affiliation(s)
- Ali Hariri
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, United States
| | - Jeanne Lemaster
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, United States
| | - Junxin Wang
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, United States
| | | | - Daniel L. Chao
- Shiley Eye Institute, Department of Ophthalmology, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, United States
| | - Jesse V. Jokerst
- Department of NanoEngineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, United States
- Materials Science and Engineering Program, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, United States
- Department of Radiology, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92092, United States
| |
Collapse
|
44
|
Erfanzadeh M, Kumavor PD, Zhu Q. Laser scanning laser diode photoacoustic microscopy system. PHOTOACOUSTICS 2018; 9:1-9. [PMID: 29201646 PMCID: PMC5699884 DOI: 10.1016/j.pacs.2017.10.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 09/21/2017] [Accepted: 10/16/2017] [Indexed: 05/05/2023]
Abstract
The development of low-cost and fast photoacoustic microscopy systems enhances the clinical applicability of photoacoustic imaging systems. To this end, we present a laser scanning laser diode-based photoacoustic microscopy system. In this system, a 905 nm, 325 W maximum output peak power pulsed laser diode with 50 ns pulsewidth is utilized as the light source. A combination of aspheric and cylindrical lenses is used for collimation of the laser diode beam. Two galvanometer scanning mirrors steer the beam across a focusing aspheric lens. The lateral resolution of the system was measured to be ∼21 μm using edge spread function estimation. No averaging was performed during data acquisition. The imaging speed is ∼370 A-lines per second. Photoacoustic microscopy images of human hairs, ex vivo mouse ear, and ex vivo porcine ovary are presented to demonstrate the feasibility and potentials of the proposed system.
Collapse
Affiliation(s)
- Mohsen Erfanzadeh
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Patrick D. Kumavor
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA
| | - Quing Zhu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO 63130, USA
- Corresponding author.
| |
Collapse
|
45
|
Mozaffarzadeh M, Yan Y, Mehrmohammadi M, Makkiabadi B. Enhanced linear-array photoacoustic beamforming using modified coherence factor. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-10. [PMID: 29446261 DOI: 10.1117/1.jbo.23.2.026005] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Accepted: 01/25/2018] [Indexed: 05/08/2023]
Abstract
Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound imaging and the contrast of optical imaging. For linear-array PAI, a beamformer can be used as the reconstruction algorithm. Delay-and-sum (DAS) is the most prevalent beamforming algorithm in PAI. However, using DAS beamformer leads to low-resolution images as well as high sidelobes due to nondesired contribution of off-axis signals. Coherence factor (CF) is a weighting method in which each pixel of the reconstructed image is weighted, based on the spatial spectrum of the aperture, to mainly improve the contrast. We demonstrate that the numerator of the formula of CF contains a DAS algebra and propose the use of a delay-multiply-and-sum beamformer instead of the available DAS on the numerator. The proposed weighting technique, modified CF (MCF), has been evaluated numerically and experimentally compared to CF. It was shown that MCF leads to lower sidelobes and better detectable targets. The quantitative results of the experiment (using wire targets) show that MCF leads to for about 45% and 40% improvement, in comparison with CF, in the terms of signal-to-noise ratio and full-width-half-maximum, respectively.
Collapse
Affiliation(s)
- Moein Mozaffarzadeh
- Research Center for Biomedical Technologies and Robotics, Institute for Advanced Medical Technologie, Iran
- Tarbiat Modares University, Department of Biomedical Engineering, Tehran, Iran
| | - Yan Yan
- Wayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States
| | - Mohammad Mehrmohammadi
- Wayne State University, Department of Biomedical Engineering, Detroit, Michigan, United States
| | - Bahador Makkiabadi
- Research Center for Biomedical Technologies and Robotics, Institute for Advanced Medical Technologie, Iran
- Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Sch, Iran
| |
Collapse
|
46
|
Upputuri PK, Pramanik M. Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-4. [PMID: 28952240 DOI: 10.1117/1.jbo.22.9.090501] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Accepted: 09/05/2017] [Indexed: 05/09/2023]
Abstract
We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000 Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging. Cortical vasculature is imaged in scan time of 5 s with high signal-to-noise ratio ∼48. To examine the ability for dynamic imaging, we monitored the fast uptake and clearance process of indocyanine green in the rat brain. The system will find applications to study neurofunctional activities, characterization of pharmacokinetic, and biodistribution profiles in the development process of drugs or imaging agents.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore, Singapore
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore, Singapore
| |
Collapse
|
47
|
Hariri A, Fatima A, Mohammadian N, Mahmoodkalayeh S, Ansari MA, Bely N, Avanaki MRN. Development of low-cost photoacoustic imaging systems using very low-energy pulsed laser diodes. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:75001. [PMID: 28697234 DOI: 10.1117/1.jbo.22.7.075001] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2017] [Accepted: 06/19/2017] [Indexed: 05/24/2023]
Abstract
With the growing application of photoacoustic imaging (PAI) in medical fields, there is a need to make them more compact, portable, and affordable. Therefore, we designed very low-cost PAI systems by replacing the expensive and sophisticated laser with a very low-energy laser diode. We implemented photoacoustic (PA) microscopy, both reflection and transmission modes, as well as PA computed tomography systems. The images obtained from tissue-mimicking phantoms and biological samples determine the feasibility of using a very low-energy laser diode in these configurations.
Collapse
Affiliation(s)
- Ali Hariri
- Wayne State University, Bioengineering Department, Detroit, Michigan, United StatesbUniversity of California, Department of NanoEngineering, San Diego, California, United States
| | - Afreen Fatima
- Wayne State University, Bioengineering Department, Detroit, Michigan, United States
| | - Nafiseh Mohammadian
- Wayne State University, Bioengineering Department, Detroit, Michigan, United States
| | | | - Mohammad Ali Ansari
- Shahid Beheshti University, Laser and Plasma Research Institute, Tehran, Iran
| | - Nicholas Bely
- Wayne State University, Bioengineering Department, Detroit, Michigan, United States
| | - Mohammad R N Avanaki
- Wayne State University, Bioengineering Department, Detroit, Michigan, United StatesdWayne State University, School of Medicine, Department Neurology, Detroit, Michigan, United StateseBarbara Ann Karmanos Cancer Institute, Detroit, Michigan, United States
| |
Collapse
|
48
|
Upputuri PK, Periyasamy V, Kalva SK, Pramanik M. A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging. J Vis Exp 2017:55811. [PMID: 28671657 PMCID: PMC5608463 DOI: 10.3791/55811] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
In vivo small-animal imaging has an important role to play in preclinical studies. Photoacoustic tomography (PAT) is an emerging hybrid imaging modality that shows great potential for both preclinical and clinical applications. Conventional optical parametric oscillator-based PAT (OPO-PAT) systems are bulky and expensive and cannot provide high-speed imaging. Recently, pulsed-laser diodes (PLDs) have been successfully demonstrated as an alternative excitation source for PAT. Pulsed-laser diode PAT (PLD-PAT) has been successfully demonstrated for high-speed imaging on photoacoustic phantoms and biological tissues. This work provides a visualized experimental protocol for in vivo brain imaging using PLD-PAT. The protocol includes the compact PLD-PAT system configuration and its description, animal preparation for brain imaging, and a typical experimental procedure for 2D cross-sectional rat brain imaging. The PLD-PAT system is compact and cost-effective and can provide high-speed, high-quality imaging. Brain images collected in vivo at various scan speeds are presented.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- School of Chemical and Biomedical Engineering, Nanyang Technological University
| | - Vijitha Periyasamy
- School of Chemical and Biomedical Engineering, Nanyang Technological University
| | - Sandeep Kumar Kalva
- School of Chemical and Biomedical Engineering, Nanyang Technological University
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University;
| |
Collapse
|
49
|
Gawale Y, Adarsh N, Kalva SK, Joseph J, Pramanik M, Ramaiah D, Sekar N. Carbazole-Linked Near-Infrared Aza-BODIPY Dyes as Triplet Sensitizers and Photoacoustic Contrast Agents for Deep-Tissue Imaging. Chemistry 2017; 23:6570-6578. [DOI: 10.1002/chem.201605702] [Citation(s) in RCA: 72] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Indexed: 02/02/2023]
Affiliation(s)
- Yogesh Gawale
- Dyestuff Technology Department; Institute of Chemical Technology; Matunga, Mumbai 400 019 India
| | - Nagappanpillai Adarsh
- Chemical Sciences and Technology Division; CSIR-National Institute for Interdisciplinary Science and Technology; Thiruvananthapuram 695 019 Kerala India
| | - Sandeep Kumar Kalva
- School of Chemical and Biomedical Engineering; Nanyang Technological University; 62 Nanyang Drive Singapore 637459 Singapore
| | - Joshy Joseph
- Chemical Sciences and Technology Division; CSIR-National Institute for Interdisciplinary Science and Technology; Thiruvananthapuram 695 019 Kerala India
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering; Nanyang Technological University; 62 Nanyang Drive Singapore 637459 Singapore
| | - Danaboyina Ramaiah
- CSIR-North East Institute of Science and Technology, Jorhat; 785 006 Assam India
| | - Nagaiyan Sekar
- Dyestuff Technology Department; Institute of Chemical Technology; Matunga, Mumbai 400 019 India
| |
Collapse
|
50
|
Wong TTW, Zhou Y, Garcia-Uribe A, Li L, Maslov K, Lin L, Wang LV. Use of a single xenon flash lamp for photoacoustic computed tomography of multiple-centimeter-thick biological tissue ex vivo and a whole mouse body in vivo. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:41003. [PMID: 27775747 PMCID: PMC5075722 DOI: 10.1117/1.jbo.22.4.041003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Accepted: 10/10/2016] [Indexed: 05/04/2023]
Abstract
While lasers have been commonly used as illumination sources in photoacoustic (PA) imaging, their high purchase and maintenance costs, as well as their bulkiness, have hindered the rapid clinical dissemination of PA imaging. With this in mind, we explore an alternative illumination source for PA tomography—a xenon flash lamp with high pulse energy and a microsecond pulse width. We demonstrate that, by using a single xenon flash lamp, we can image both a black latex cord placed in chicken breast tissue at a depth of up to 3.5 cm ex vivo and an entire mouse body in vivo. Our findings indicate that the xenon flash lamp, producing optical illumination that is safe for humans, can be potentially applied to human tissue imaging.
Collapse
Affiliation(s)
- Terence T. W. Wong
- Washington University in St. Louis, Optical Imaging Laboratory, Department of Biomedical Engineering, One Brookings Drive, Saint Louis, Missouri 63130, United States
| | - Yong Zhou
- Washington University in St. Louis, Optical Imaging Laboratory, Department of Biomedical Engineering, One Brookings Drive, Saint Louis, Missouri 63130, United States
| | - Alejandro Garcia-Uribe
- Washington University in St. Louis, Optical Imaging Laboratory, Department of Biomedical Engineering, One Brookings Drive, Saint Louis, Missouri 63130, United States
| | - Lei Li
- Washington University in St. Louis, Optical Imaging Laboratory, Department of Biomedical Engineering, One Brookings Drive, Saint Louis, Missouri 63130, United States
| | - Konstantin Maslov
- Washington University in St. Louis, Optical Imaging Laboratory, Department of Biomedical Engineering, One Brookings Drive, Saint Louis, Missouri 63130, United States
| | - Li Lin
- Washington University in St. Louis, Optical Imaging Laboratory, Department of Biomedical Engineering, One Brookings Drive, Saint Louis, Missouri 63130, United States
| | - Lihong V. Wang
- Washington University in St. Louis, Optical Imaging Laboratory, Department of Biomedical Engineering, One Brookings Drive, Saint Louis, Missouri 63130, United States
- Address all correspondence to: Lihong V. Wang, E-mail:
| |
Collapse
|