1
|
Mechó-García M, Arcas-Carbonell M, Orduna-Hospital E, Sánchez-Cano A, González-Méijome JM. The Influence of Accommodative Demand on Ocular Aberrations: A Study of Zernike Coefficients Repeatability and Variability. Curr Eye Res 2024:1-10. [PMID: 39004896 DOI: 10.1080/02713683.2024.2378009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 07/03/2024] [Indexed: 07/16/2024]
Abstract
PURPOSE To evaluate the repeatability of the Zernike coefficients in healthy eyes when monocular accommodation was stimulated at different vergences demands. METHODS A total of 36 right eyes from healthy volunteers were prospectively and consecutively recruited for this study. Wavefront aberrometry was conducted to objectively characterize the ocular optical quality during accommodation, from the individual's far point to a 5 D accommodation demand in steps of 0.5 D. The repeatability of Zernike coefficients up to the fourth order was assessed by calculating the within-eye repeatability (Sw), the coefficient of repeatability (CR), the coefficient of variation (CV), and the intraclass correlation coefficient (ICC) as an indicator of measurement reliability. RESULTS Correlation among repeated measurements showed high reliability (ICC > 0.513) for all parameters measured except some fourth-order Zernike coefficients, C(4, -4) (ICC < 0.766), C(4, -2) (ICC < 0.875), C(4, 2) (ICC < 0.778) and C(4, 4) (ICC < 0.811). Greater repeatability and less variability were obtained for high-order Zernike coefficients (CR < 0.154), although an increase in CR in the coefficients analyzed was observed with increasing accommodative demand. No clear trend was evident in CV; however, it was observed that the low-order Zernike coefficients exhibit lower CV (CV < 1.93) compared to the high-order Zernike coefficients (CV > 0). CONCLUSIONS The reliability of Zernike coefficients up to the fourth order in healthy young individuals demonstrated a strong consistency in measuring terms up to the fourth order, with more variability observed for high-order terms. The Zernike coefficients up to the third order exhibited the highest level of repeatability.
Collapse
Affiliation(s)
- María Mechó-García
- Clinical & Experimental Optometry Research Lab, Physics Center of Minho, and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal
| | - María Arcas-Carbonell
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España
- Aragon Health Research Institute (IIS Aragon), Zaragoza, Aragon, Spain
| | - Elvira Orduna-Hospital
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España
- Aragon Health Research Institute (IIS Aragon), Zaragoza, Aragon, Spain
| | - Ana Sánchez-Cano
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España
- Aragon Health Research Institute (IIS Aragon), Zaragoza, Aragon, Spain
| | - José Manuel González-Méijome
- Clinical & Experimental Optometry Research Lab, Physics Center of Minho, and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal
| |
Collapse
|
2
|
Pourreza Ghoushchi V, Mompeán J, Prieto PM, Artal P. Contrast sensitivity is resilient to induced fast periodic defocus oscillations. BIOMEDICAL OPTICS EXPRESS 2024; 15:3848-3858. [PMID: 38867768 PMCID: PMC11166443 DOI: 10.1364/boe.521340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 05/08/2024] [Accepted: 05/09/2024] [Indexed: 06/14/2024]
Abstract
This study investigates the potential effects of periodic defocus oscillations on contrast sensitivity. Sinusoidal fluctuations at 5, 15, and 25 Hz, with defocus peak-to-valley values ranging from 0.15 to 3 D, were induced by means of a focus-tunable lens after calibrating its dynamic behavior. Monocular contrast sensitivity was measured on five young emmetropic subjects. The experimental data shows that contrast sensitivity loss due to defocus fluctuations is low for a wide range of frequencies and amplitudes. Only for the more severe case studied (25 Hz, ± 1.5 D) contrast threshold showed a clear increase in most subjects. Qualitative comparison of the empirical data with a simulation of modulation loss due to time integration of defocused retinal point spread functions, suggests a short integration time by the eye for defocus blur, around or even below a hundredth of a second.
Collapse
Affiliation(s)
- Vahid Pourreza Ghoushchi
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Juan Mompeán
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Pedro M. Prieto
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| | - Pablo Artal
- Laboratorio de Óptica, Instituto Universitario de Investigación en Óptica y Nanofísica, Universidad de Murcia, Campus de Espinardo (Edificio 34), E-30100 Murcia, Spain
| |
Collapse
|
3
|
Goswami S, Bharadwaj SR. Temporal fluctuations in defocus may reverse the acuity loss encountered with induced refractive errors. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2023; 40:2008-2018. [PMID: 38038066 DOI: 10.1364/josaa.497091] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Accepted: 10/02/2023] [Indexed: 12/02/2023]
Abstract
A recent template-matching model hypothesized that simulated visual acuity loss with uncorrected refractive errors may be recovered by adding temporal defocus fluctuations up to the magnitude of the refractive error. Acuity recovery saturates or gets attenuated beyond this magnitude. These predictions were confirmed for monocular high-contrast visual acuity of 10 young, cyclopleged adults with 0.5-2.0D of induced myopia combined with the same range of temporal defocus fluctuations at 4.0 Hz frequency. The outcomes reinforce that spatial resolution may be optimized by averaging time-varying defocus over the entire stimulus presentation epoch or around the point of least defocus within this epoch.
Collapse
|
4
|
Yequan H, Jingyun G, Yu G, Yan C, Zhechuang L, Xuechuan D, Xiaolin N. A focusing method on refraction topography measurement. Sci Rep 2023; 13:16440. [PMID: 37777596 PMCID: PMC10542780 DOI: 10.1038/s41598-023-42950-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Accepted: 09/16/2023] [Indexed: 10/02/2023] Open
Abstract
This paper introduces a novel focusing method Refraction Topography (RT) for wide-angle refraction measurement. The agreement of the test results obtained using RT is evaluated against simulation results and expected refraction. RT develops a refraction algorithm on fundus images at various focusing statuses. Unlike conventional techniques for peripheral refraction measurement, RT requires the subject to stare at a stationary fixation target. The refraction algorithm calculates the focus measure for multiple images at the Point of Interest and formulates them into a focus profile. The maximum focus measure correlates with the optimal focus position. Refraction Characterization Function (RCF) is proposed to translate the focus position into refraction determination, thus forming the refraction topography. The refraction characterization of RT optical system is performed using Isabel schematic eye. Three test eyes of - 15 D, 0 D, and + 15 D are defined, and expected refraction is obtained through simulation on an independent test schematic eye. Both simulation results and experimental results are obtained by combining the test eyes and RT system. Test results are compared with simulation results and expected refraction. The study demonstrates agreement among the test results, simulation results, and expected refraction on three test eyes.
Collapse
Affiliation(s)
- Huang Yequan
- School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing, China.
| | - Guo Jingyun
- Shenzhen Thondar Technology Co. Ltd, Shenzhen, China
| | - Guo Yu
- Shenzhen Thondar Technology Co. Ltd, Shenzhen, China
| | - Cui Yan
- Shenzhen Thondar Technology Co. Ltd, Shenzhen, China
| | - Li Zhechuang
- Shenzhen Thondar Technology Co. Ltd, Shenzhen, China
| | - Dong Xuechuan
- Shenzhen Thondar Technology Co. Ltd, Shenzhen, China
| | - Ning Xiaolin
- School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing, China
| |
Collapse
|
5
|
Zhang Q, Hu Q, Berlage C, Kner P, Judkewitz B, Booth M, Ji N. Adaptive optics for optical microscopy [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:1732-1756. [PMID: 37078027 PMCID: PMC10110298 DOI: 10.1364/boe.479886] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2022] [Revised: 03/06/2023] [Accepted: 03/06/2023] [Indexed: 05/03/2023]
Abstract
Optical microscopy is widely used to visualize fine structures. When applied to bioimaging, its performance is often degraded by sample-induced aberrations. In recent years, adaptive optics (AO), originally developed to correct for atmosphere-associated aberrations, has been applied to a wide range of microscopy modalities, enabling high- or super-resolution imaging of biological structure and function in complex tissues. Here, we review classic and recently developed AO techniques and their applications in optical microscopy.
Collapse
Affiliation(s)
- Qinrong Zhang
- Department of Physics, Department of Molecular & Cellular Biology, University of California, Berkeley, CA 94720, USA
| | - Qi Hu
- Department of Engineering Science, University of Oxford, Oxford OX1 3PJ, UK
| | - Caroline Berlage
- Charité - Universitätsmedizin Berlin, Einstein Center for Neurosciences, NeuroCure Cluster of Excellence, 10117 Berlin, Germany
- Humboldt-Universität zu Berlin, Institute for Biology, 10099 Berlin, Germany
| | - Peter Kner
- School of Electrical and Computer Engineering, University of Georgia, Athens, GA 30602, USA
| | - Benjamin Judkewitz
- Charité - Universitätsmedizin Berlin, Einstein Center for Neurosciences, NeuroCure Cluster of Excellence, 10117 Berlin, Germany
| | - Martin Booth
- Department of Engineering Science, University of Oxford, Oxford OX1 3PJ, UK
| | - Na Ji
- Department of Physics, Department of Molecular & Cellular Biology, University of California, Berkeley, CA 94720, USA
| |
Collapse
|
6
|
Goswami S, Bharadwaj SR. Impact of temporal fluctuations in optical defocus on visual acuity: Empirical results and modeling outcomes. J Vis 2023; 23:14. [PMID: 36971683 PMCID: PMC10064932 DOI: 10.1167/jov.23.3.14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/29/2023] Open
Abstract
Optical defocus in human eyes is seldom steady during naturalistic steady-state viewing. It fluctuates by 0.3 to 0.5 diopters (D) from accommodative microfluctuations and by 1.5 to 2.5 D in dysfunctions such as spasm of near reflex, both with ≤2 Hz low-pass frequency spectra. This study observed losses in monocular visual acuity of cyclopleged adults who encountered varying amplitude (0.25-2.0 D) and temporal frequency (0.25-2.0 Hz) combinations of sinusoidal defoci induced using an electrically tunable lens. Visual acuity, recorded for 300-ms flashes of Sloan optotype presentation using the method of constant stimuli, deteriorated with defocus amplitude at a rate steeper for lower than higher temporal frequencies. A template matching model of acuity, incorporating optical and neural low-pass filters, neural noise, and a cross-correlated decision operator, showed the best match with empirical data when acuity was governed by the minimum defocus available during optotype display. This criterion minimized acuity loss for higher temporal frequencies due to the increased probability of zero-defocus encounters within the presentation duration. Other decision criteria such as defocus averaging across the entire or parts of the presentation duration yielded less satisfactory results. These results imply that vision loss in humans encountering broadband time-varying defocus is dictated by the dominant low frequencies, with higher frequencies largely compensated using the least defocus decision strategy.
Collapse
Affiliation(s)
- Sabyasachi Goswami
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, Telangana, India
- Prof Brien Holden Eye Research Centre, Hyderabad Eye Research Foundation, L V Prasad Eye Institute, Hyderabad, Telangana, India
| | - Shrikant R Bharadwaj
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, Telangana, India
- Prof Brien Holden Eye Research Centre, Hyderabad Eye Research Foundation, L V Prasad Eye Institute, Hyderabad, Telangana, India
| |
Collapse
|
7
|
Gu B, Zhang Y. Adaptive optics wavefront correction using a damped transpose matrix of the influence function. PHOTONICS RESEARCH 2022; 10:1777-1786. [PMID: 37153536 PMCID: PMC10162714 DOI: 10.1364/prj.452364] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
To assess the performance of adaptive optics and predict an optimal wavefront correction, we built a wavefront reconstructor with a damped transpose matrix of the influence function. Using an integral control strategy, we tested this reconstructor with four deformable mirrors in an experimental system, an adaptive optics scanning laser ophthalmoscope, and an adaptive optics near-confocal ophthalmoscope. Testing results proved that this reconstructor could ensure a stable and precise correction for wavefront aberration compared to a conventional optimal reconstructor formed by the inverse matrix of the influence function. This method may provide a helpful tool for testing, evaluating, and optimizing adaptive optics systems.
Collapse
Affiliation(s)
- Boyu Gu
- Doheny Eye Institute, 150 N Orange Grove Boulevard, Pasadena, California 91103, USA
- Department of Ophthalmology, University of California - Los Angeles, 100 Stein Plaza Driveway, Los Angeles, CA 90095, USA
| | - Yuhua Zhang
- Doheny Eye Institute, 150 N Orange Grove Boulevard, Pasadena, California 91103, USA
- Department of Ophthalmology, University of California - Los Angeles, 100 Stein Plaza Driveway, Los Angeles, CA 90095, USA
| |
Collapse
|
8
|
Bamdad S, Momeni-Moghaddam H, Abdolahian M, Piñero DP. Agreement of wavefront-based refraction, dry and cycloplegic autorefraction with subjective refraction. JOURNAL OF OPTOMETRY 2022; 15:100-106. [PMID: 32896507 PMCID: PMC8712579 DOI: 10.1016/j.optom.2020.08.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 06/07/2020] [Accepted: 08/17/2020] [Indexed: 05/26/2023]
Abstract
PURPOSE To evaluate the agreement of dry, and cycloplegic autorefraction and wavefront-based refraction with subjective refraction. METHOD 83 subjects aged 19-57 years were included in this cross-sectional study. Refractive status was determined using four methods including subjective refraction, wavefront-based refraction, dry and cycloplegic autorefraction. Refractive data were recorded as sphere, cylinder and spherical equivalent (SE). Power vector components were used to compare the astigmatism obtained using the different methods of refraction. RESULTS The more negative spherical, cylindrical and SE components were obtained using dry autorefraction, wavefront-based refraction and dry autorefraction, respectively. The less negative spherical, cylindrical and SE components were obtained using cycloplegic autorefraction, subjective refraction and cycloplegic autorefraction, respectively. Considering the spherical component, there was a statistically significant hyperopic shift (0.12 ± 0.29 D, p = 0.001) with cycloplegic autorefraction and a significant myopic shift (-0.17 ± 0.32 D, p < 0.001) with dry autorefraction compared to subjective refraction, while the difference between wavefront-based and subjective refraction was not significant statistically (p = 0.145). The calculated cylindrical component using subjective refraction showed statistically significant difference with dry auto-refraction (p < 0.001), cycloplegic auto-refraction (p = 0.041) and wavefront refraction (p < 0.001). The highest correlation with subjective refraction in sphere, cylinder and SE was observed for cycloplegic auto-refraction (rs = 0.967), dry auto-refraction (rs = 0.983) and cycloplegic auto-refraction (rs = 0.982), respectively. CONCLUSIONS As subjective refraction is gold standard in our study, sphere in cycloplegic auto-refraction and astigmatism in dry auto-refraction showed better agreement and correlation.
Collapse
Affiliation(s)
- Shahram Bamdad
- Poostchi Ophthalmology Research Center, Shiraz University Of Medical Sciences, Shiraz, Iran
| | - Hamed Momeni-Moghaddam
- Health Promotion Research Center, Zahedan University of Medical Sciences, Zahedan, Iran; Department of Optometry, School of Paramedical Sciences, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Milad Abdolahian
- Poostchi Ophthalmology Research Center, Shiraz University Of Medical Sciences, Shiraz, Iran.
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| |
Collapse
|
9
|
Leroux CE, Leahy C, Fontvieille C, Bardin F. The random walk of accommodation fluctuations. BIOMEDICAL OPTICS EXPRESS 2021; 12:6897-6908. [PMID: 34858687 PMCID: PMC8606129 DOI: 10.1364/boe.433926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 07/19/2021] [Accepted: 08/03/2021] [Indexed: 06/13/2023]
Abstract
The focusing distance of the eye fluctuates during accommodation. However, the visual role of these accommodation fluctuations is not yet fully understood. The fluctuation complexity is one of the obstacles to this long standing challenge in visual science. In this work we seek to develop a statistical approach that i) accurately describes experimental measurements and ii) directly generates randomized and realistic simulations of accommodation fluctuations for use in future experiments. To do so we use the random walk approach, which is usually appropriate to describe the dynamics of systems that combine both randomness and memory.
Collapse
Affiliation(s)
| | - Conor Leahy
- Carl Zeiss Meditec, Inc., 5300 Central Parkway, Dublin, CA 94568, USA
| | | | - Fabrice Bardin
- Laboratoire MIPA, Université de Nîmes, Sites des Carmes, Nîmes, 30000, France
| |
Collapse
|
10
|
Georgiev S, Kumar A, Findl O, Hirnschall N, Niederleithner M, Kendrisic M, Drexler W, Leitgeb RA. Digital ocular swept source optical coherence aberrometry. BIOMEDICAL OPTICS EXPRESS 2021; 12:6762-6779. [PMID: 34858679 PMCID: PMC8606149 DOI: 10.1364/boe.430596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 08/09/2021] [Accepted: 08/11/2021] [Indexed: 06/13/2023]
Abstract
Ocular aberrometry is an essential technique in vision science and ophthalmology. We demonstrate how a phase-sensitive single mode fiber-based swept source optical coherence tomography (SS-OCT) setup can be employed for quantitative ocular aberrometry with digital adaptive optics (DAO). The system records the volumetric point spread function at the retina in a de-scanning geometry using a guide star pencil beam. Succeeding test-retest repeatability assessment with defocus and astigmatism analysis on a model eye within ± 3 D dynamic range, the feasibility of technique is demonstrated in-vivo at a B-scan rate of >1 kHz in comparison with a commercially available aberrometer.
Collapse
Affiliation(s)
- Stefan Georgiev
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
- Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria
- Contributed equally
| | - Abhishek Kumar
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
- Wavesense Engineering GmbH, Vienna, Austria
- Contributed equally
| | - Oliver Findl
- Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria
| | - Nino Hirnschall
- Vienna Institute for Research in Ocular Surgery, Hanusch Hospital, Vienna, Austria
| | - Michael Niederleithner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Milana Kendrisic
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Wolfgang Drexler
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Rainer A. Leitgeb
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
- Christian Doppler Laboratory for Innovative Optical Imaging and Its Translation to Medicine, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| |
Collapse
|
11
|
Abstract
Early detection and monitoring are critical to the diagnosis and management of glaucoma, a progressive optic neuropathy that causes irreversible blindness. Optical coherence tomography (OCT) has become a commonly utilized imaging modality that aids in the detection and monitoring of structural glaucomatous damage. Since its inception in 1991, OCT has progressed through multiple iterations, from time-domain OCT, to spectral-domain OCT, to swept-source OCT, all of which have progressively improved the resolution and speed of scans. Even newer technological advancements and OCT applications, such as adaptive optics, visible-light OCT, and OCT-angiography, have enriched the use of OCT in the evaluation of glaucoma. This article reviews current commercial and state-of-the-art OCT technologies and analytic techniques in the context of their utility for glaucoma diagnosis and management, as well as promising future directions. Expected final online publication date for the Annual Review of Vision Science, Volume 7 is September 2021. Please see http://www.annualreviews.org/page/journal/pubdates for revised estimates.
Collapse
Affiliation(s)
- Alexi Geevarghese
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY 10016, USA;
| | - Gadi Wollstein
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY 10016, USA; .,Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, New York 11201, USA.,Center for Neural Science, NYU College of Arts and Sciences, New York, NY 10003, USA
| | - Hiroshi Ishikawa
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY 10016, USA; .,Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, New York 11201, USA
| | - Joel S Schuman
- Department of Ophthalmology, NYU Langone Health, NYU Grossman School of Medicine, New York, NY 10016, USA; .,Department of Biomedical Engineering, NYU Tandon School of Engineering, Brooklyn, New York 11201, USA.,Center for Neural Science, NYU College of Arts and Sciences, New York, NY 10003, USA.,Department of Physiology and Neuroscience, NYU Langone Health, NYU Grossman School of Medicine, New York, NY 10016, USA
| |
Collapse
|
12
|
Rae SM, Price HC. The effect of soft contact lens wear and time from blink on wavefront aberration measurement variation. Clin Exp Optom 2021; 92:274-82. [DOI: 10.1111/j.1444-0938.2009.00377.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Affiliation(s)
- Sheila M Rae
- Vision and Eye Research Unit, Anglia Ruskin University, Cambridge, United Kingdom
E‐mail:
| | - Holly C Price
- Vision and Eye Research Unit, Anglia Ruskin University, Cambridge, United Kingdom
E‐mail:
| |
Collapse
|
13
|
Repeatability of corneal and ocular aberration measurements and changes in aberrations over one week. Clin Exp Optom 2021; 92:253-66. [DOI: 10.1111/j.1444-0938.2009.00364.x] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
14
|
Atchison DA. Recent advances in measurement of monochromatic aberrations of human eyes. Clin Exp Optom 2021; 88:5-27. [PMID: 15658922 DOI: 10.1111/j.1444-0938.2005.tb06659.x] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2004] [Revised: 11/18/2004] [Accepted: 11/27/2004] [Indexed: 11/29/2022] Open
Abstract
The field of aberrations of the human eye is moving rapidly, being driven by the desire to monitor and optimise vision following refractive surgery. It is important for ophthalmologists and optometrists to have an understanding of the magnitude of various aberrations and how these are likely to be affected by refractive surgery and other corrections. In this paper, I consider methods used to measure aberrations, the magnitude of aberrations in general populations and how these are affected by various factors (for example, age, refractive error, accommodation and refractive surgery) and how aberrations and their correction affect spatial visual performance.
Collapse
Affiliation(s)
- David A Atchison
- School of Optometry, Queensland University of Technology, Kelvin Grove, QLD 4059, Australia
| |
Collapse
|
15
|
Abstract
Adaptive optics (AO) is a technique that corrects for optical aberrations. It was originally proposed to correct for the blurring effect of atmospheric turbulence on images in ground-based telescopes and was instrumental in the work that resulted in the Nobel prize-winning discovery of a supermassive compact object at the centre of our galaxy. When AO is used to correct for the eye's imperfect optics, retinal changes at the cellular level can be detected, allowing us to study the operation of the visual system and to assess ocular health in the microscopic domain. By correcting for sample-induced blur in microscopy, AO has pushed the boundaries of imaging in thick tissue specimens, such as when observing neuronal processes in the brain. In this primer, we focus on the application of AO for high-resolution imaging in astronomy, vision science and microscopy. We begin with an overview of the general principles of AO and its main components, which include methods to measure the aberrations, devices for aberration correction, and how these components are linked in operation. We present results and applications from each field along with reproducibility considerations and limitations. Finally, we discuss future directions.
Collapse
|
16
|
Akondi V, Dubra A. Multi-layer Shack-Hartmann wavefront sensing in the point source regime. BIOMEDICAL OPTICS EXPRESS 2021; 12:409-432. [PMID: 33520390 PMCID: PMC7818966 DOI: 10.1364/boe.411189] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 12/07/2020] [Accepted: 12/08/2020] [Indexed: 05/08/2023]
Abstract
The Shack-Hartmann wavefront sensor (SHWS) is often operated under the assumption that the sensed light can be described by a single wavefront. In biological tissues and other multi-layered samples, secondary wavefronts from axially and/or transversely displaced regions can lead to artifactual aberrations. Here, we evaluate these artifactual aberrations in a simulated ophthalmic SHWS by modeling the beacons that would be generated by a two-layer retina in human and mouse eyes. Then, we propose formulae for calculating a minimum SHWS centroid integration area to mitigate these aberrations by an order of magnitude, potentially benefiting SHWS-based metrology and adaptive optics systems such as those used for retinal imaging and microscopy.
Collapse
Affiliation(s)
- Vyas Akondi
- Byers Eye Institute, Stanford University, Palo Alto, California 94303, USA
| | - Alfredo Dubra
- Byers Eye Institute, Stanford University, Palo Alto, California 94303, USA
| |
Collapse
|
17
|
Soomro T, Shah N, Niestrata-Ortiz M, Yap T, Normando EM, Cordeiro MF. Recent advances in imaging technologies for assessment of retinal diseases. Expert Rev Med Devices 2020; 17:1095-1108. [PMID: 32885710 DOI: 10.1080/17434440.2020.1816167] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Retinal imaging is a key investigation in ophthalmology. New devices continue to be created to keep up with the demand for better imaging modalities in this field. This review looks to highlight current trends and the future of retinal imaging. AREAS COVERED This review looks at the advances in topographical imaging, photoacoustic microscopy, optical coherence tomography and molecular imaging. There is future scoping on further advances in retinal imaging. EXPERT OPINION Retinal imaging continues to develop at a rapid pace to improve diagnosis and management of patients. We will see the development of big data to gain powerful insights and new technologies such as teleophthalmology mature in the future.
Collapse
Affiliation(s)
- Taha Soomro
- Imperial College Ophthalmology Research Group, Western Eye Hospital , 153-173 Marylebone Road, London, UK
| | - Neil Shah
- Imperial College Ophthalmology Research Group, Western Eye Hospital , 153-173 Marylebone Road, London, UK
| | - Magdalena Niestrata-Ortiz
- Imperial College Ophthalmology Research Group, Western Eye Hospital , 153-173 Marylebone Road, London, UK
| | - Timothy Yap
- Imperial College Ophthalmology Research Group, Western Eye Hospital , 153-173 Marylebone Road, London, UK
| | - Eduardo M Normando
- Imperial College Ophthalmology Research Group, Western Eye Hospital , 153-173 Marylebone Road, London, UK
| | - M Francesca Cordeiro
- Imperial College Ophthalmology Research Group, Western Eye Hospital , 153-173 Marylebone Road, London, UK
| |
Collapse
|
18
|
Acosta E, Olvera-Angeles M, González-Amador E, Sasian J, Schwiegerling J, Arines J. Wavefront coding with Jacobi-Fourier phase masks for retinal imaging. APPLIED OPTICS 2020; 59:G234-G238. [PMID: 32749338 DOI: 10.1364/ao.391941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 06/20/2020] [Indexed: 06/11/2023]
Abstract
Wavefront coding is a technique that combines optical phase elements and digital signal processing in order to increase the effective depth of focus of optical systems. The success of wavefront coding lies in the design of a suitable phase mask placed at the system's aperture. This element allows for image formation invariant under the effects of different second-order optical aberrations. In optical systems limited by temporally or spatially varying high-order aberrations, the use of wavefront coding has not been fully demonstrated. Here we propose the choice of Jacobi-Fourier shaped phase masks to produce sharp and clear retinal images of living eyes. To demonstrate the potential use of the technique, we analyze the performance of the Jacobi-Fourier phase masks through experimental simulations to alleviate aberrations for different eye aberrations. We will show that the best mask choice is robust to noise while keeping acceptable resolution and reducing image artefacts.
Collapse
|
19
|
Zhang Y, Wang X, Clark ME, Curcio CA, Owsley C. Imaging of Age-Related Macular Degeneration by Adaptive Optics Scanning Laser Ophthalmoscopy in Eyes With Aged Lenses or Intraocular Lenses. Transl Vis Sci Technol 2020; 9:41. [PMID: 32855887 PMCID: PMC7422803 DOI: 10.1167/tvst.9.8.41] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Accepted: 06/12/2020] [Indexed: 12/18/2022] Open
Abstract
Purpose To assess the performance of adaptive optics scanning laser ophthalmoscopy (AOSLO) in a large sample of eyes with or without age-related macular degeneration (AMD) and with cataracts or intraocular lenses (IOLs). Methods Patients with various degrees of AMD and age-similar normal subjects underwent fundus photography. Cataract severity and IOL clarity were assessed by fundus reflex photographs. In phakic eyes, lenticular opacity was graded as nuclear, cortical, or posterior subcapsular cataract. In eyes with IOLs, lens clarity was assessed by posterior capsule opacification (PCO). Quality of AOSLO images of the macular photoreceptor mosaic was classified as good, adequate or inadequate by human graders in a subjective assessment of cone visibility. Results A total of 159 eyes in 80 subjects (41 males, 39 females, aged 72.5 ± 11.5 years, 16 normals) were examined. Seventy-nine eyes had IOLs, and 80 eyes were phakic. AOSLO produced good images in 91 eyes (57%), adequate images in eight eyes (5%), and inadequate images in 27 eyes (17%). AOSLO did not acquire images in 33 eyes (21%), because of dense lenticular opacity, widespread PCO, or problems specific to individual subjects. Conclusions AOSLO images considered at least Adequate or better for visualizing cone photoreceptors were acquired from 62% of study eyes. Translational Relevance AOSLO can be used as an additional imaging modality to investigate the structure of cone photoreceptors in research on visual function in AMD and in clinical trials involving older patients.
Collapse
Affiliation(s)
- Yuhua Zhang
- Department of Ophthalmology, University of California-Los Angeles, Los Angeles, CA, USA.,Doheny Eye Institute, Los Angeles, CA, USA
| | | | - Mark E Clark
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Christine A Curcio
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Cynthia Owsley
- Department of Ophthalmology and Visual Sciences, University of Alabama at Birmingham, Birmingham, AL, USA
| |
Collapse
|
20
|
Li Z, Zhang Q, Chou SW, Newman Z, Turcotte R, Natan R, Dai Q, Isacoff EY, Ji N. Fast widefield imaging of neuronal structure and function with optical sectioning in vivo. SCIENCE ADVANCES 2020; 6:eaaz3870. [PMID: 32494711 PMCID: PMC7209992 DOI: 10.1126/sciadv.aaz3870] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2019] [Accepted: 02/18/2020] [Indexed: 05/19/2023]
Abstract
Optical microscopy, owing to its noninvasiveness and subcellular resolution, enables in vivo visualization of neuronal structure and function in the physiological context. Optical-sectioning structured illumination microscopy (OS-SIM) is a widefield fluorescence imaging technique that uses structured illumination patterns to encode in-focus structures and optically sections 3D samples. However, its application to in vivo imaging has been limited. In this study, we optimized OS-SIM for in vivo neural imaging. We modified OS-SIM reconstruction algorithms to improve signal-to-noise ratio and correct motion-induced artifacts in live samples. Incorporating an adaptive optics (AO) module to OS-SIM, we found that correcting sample-induced optical aberrations was essential for achieving accurate structural and functional characterizations in vivo. With AO OS-SIM, we demonstrated fast, high-resolution in vivo imaging with optical sectioning for structural imaging of mouse cortical neurons and zebrafish larval motor neurons, and functional imaging of quantal synaptic transmission at Drosophila larval neuromuscular junctions.
Collapse
Affiliation(s)
- Ziwei Li
- Department of Physics, University of California, Berkeley, Berkeley, CA 94720, USA
- Department of Automation, Tsinghua University, Beijing 100084, China
| | - Qinrong Zhang
- Department of Physics, University of California, Berkeley, Berkeley, CA 94720, USA
| | - Shih-Wei Chou
- Department of Molecular and Cell Biology, University of California, Berkeley, Berkeley, CA 94720, USA
| | - Zachary Newman
- Department of Molecular and Cell Biology, University of California, Berkeley, Berkeley, CA 94720, USA
| | - Raphaël Turcotte
- Department of Physics, University of California, Berkeley, Berkeley, CA 94720, USA
| | - Ryan Natan
- Department of Physics, University of California, Berkeley, Berkeley, CA 94720, USA
| | - Qionghai Dai
- Department of Automation, Tsinghua University, Beijing 100084, China
| | - Ehud Y. Isacoff
- Department of Molecular and Cell Biology, University of California, Berkeley, Berkeley, CA 94720, USA
- Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, CA 94720, USA
- Bioscience Division, Lawrence Berkeley National Laboratory, Berkeley, Berkeley, CA 94720, USA
| | - Na Ji
- Department of Physics, University of California, Berkeley, Berkeley, CA 94720, USA
- Department of Molecular and Cell Biology, University of California, Berkeley, Berkeley, CA 94720, USA
- Helen Wills Neuroscience Institute, University of California, Berkeley, Berkeley, CA 94720, USA
- Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA
- Corresponding author.
| |
Collapse
|
21
|
Potic J, Bergin C, Giacuzzo C, Daruich A, Pournaras JA, Kowalczuk L, Behar-Cohen F, Konstantinidis L, Wolfensberger TJ. CHANGES IN VISUAL ACUITY AND PHOTORECEPTOR DENSITY USING ADAPTIVE OPTICS AFTER RETINAL DETACHMENT REPAIR. Retina 2020; 40:376-386. [PMID: 31972809 DOI: 10.1097/iae.0000000000002378] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To quantify changes in photoreceptor density using adaptive optics fundus camera in patients after retinal detachment (RD) and to correlate them with macular involvement and best-corrected visual acuity. METHODS At 1 and 3 months (M1 and M3) after vitrectomy, 194 patients underwent adaptive optics imagery in both eyes, at 5 locations, that we matched between time points using anatomical landmarks. Twenty-two patients (10 fovea-OFF [OFF] and 12 fovea-ON [ON]) had matched and analyzable adaptive optics images. We used analysis of variance for repeated measures. RESULTS Best-corrected visual acuity (logarithm of the minimum angle of resolution and Snellen equivalent [SE]) was significantly different between OFF and ON RDs at baseline: 2.0 (2.3-0.95) (SE: 20/2000) versus 0 (0.1-0) (SE: 20/20); at M1: 0.35 (0.5-0.1) (SE: 20/40) versus 0.05 (0-0.1) (SE: 20/25); and at M3: 0.25 (0.3-0.1) (SE: 20/32) versus 0 (0-0) (SE: 20/20). We observed that cone density was stable in fellow eyes between M1 and M3 (P = 0.67); decreased in treated eyes than in fellow eyes (P < 0.05); and increased postoperatively in the ON group (P = 0.02) but not in the OFF group (P = 0.97). Visual acuity and RD type were independently correlated with cone density (P = 0.004, P = 0.000). CONCLUSION Postoperative cone density was reduced in OFF RD, but also in the ON group, although the drop recovered during the 3-month follow-up. Cone density was significantly correlated with both visual acuity and type of RD at both time points.
Collapse
Affiliation(s)
- Jelena Potic
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
- Clinics for Eye Diseases, Clinical Center of Serbia, Department of Ophthalmology, School of Medicine, University of Belgrade, Belgrade, Serbia; and
| | - Ciara Bergin
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
| | - Clarice Giacuzzo
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
| | - Alejandra Daruich
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
| | - Jean-Antoine Pournaras
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
| | - Laura Kowalczuk
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
| | - Francine Behar-Cohen
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
- Centre de Recherche des Cordeliers UMRS1138, INSERM, Paris, France
| | - Lazaros Konstantinidis
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
| | - Thomas J Wolfensberger
- Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Department of Ophthalmology, University of Lausanne, Lausanne, Switzerland
| |
Collapse
|
22
|
Martínez‐Roda JA, García‐Guerra CE, Diaz‐Doutón F, Pujol J, Salvador A, Vilaseca M. Quantification of forward scattering based on the analysis of double-pass images in the frequency domain. Acta Ophthalmol 2019; 97:e1019-e1026. [PMID: 31050166 PMCID: PMC6849746 DOI: 10.1111/aos.14122] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Accepted: 03/28/2019] [Indexed: 11/26/2022]
Abstract
Purpose To assess forward intraocular scattering by means of a new parameter (Frequency Scatter Index, FSI3) based on the analysing double‐pass retinal images in the frequency domain, which minimizes the impact of aberrations on the results. Methods A prospective observational study was carried out in the Department of Ophthalmology, Hospital Universitari Mútua de Terrassa (Spain) on a group of 19 patients diagnosed with nuclear cataracts of various LOCSIII grades and a control group (CG) with nine healthy eyes. We recorded double‐pass retinal images with a custom set‐up based on a high‐sensitivity digital camera. The FSI3 was then computed using spatial frequencies below three cycles per degree. A preliminary validation of the FSI3 was performed on an artificial eye and two eyes of volunteers with and without commercial diffusers, and under defocus. Results The FSI3 was hardly affected by defocus values up to 2.50 D. The mean (and standard deviation) FSI3 values were as follows: for the CG, 1.19 (0.21); and for LOCSIII grades nuclear opacity 1, 2 and 3, 1.30 (0.12), 1.62 (0.21) and 1.85 (0.21), respectively. Eyes with cataracts showed FSI3 values significantly different than healthy eyes (p = 0.001). A good correlation (ρ = 0.861, p < 0.001) was found between the FSI3 and objective scatter index provided by a commercial instrument. Conclusion Since aberrations have little impact on the FSI3, the light scatter assessment becomes less dependent on the patient's refractive error compensation and the presence of higher‐order aberrations. The FSI3 can further the clinical and scientific understanding of forward intraocular scattering.
Collapse
Affiliation(s)
- Joan A. Martínez‐Roda
- Centre for Sensors, Instruments and Systems Development (CD6) Universitat Politècnica de Catalunya (UPC) Terrassa Spain
| | - Carlos E. García‐Guerra
- Centre for Sensors, Instruments and Systems Development (CD6) Universitat Politècnica de Catalunya (UPC) Terrassa Spain
| | - Fernando Diaz‐Doutón
- Centre for Sensors, Instruments and Systems Development (CD6) Universitat Politècnica de Catalunya (UPC) Terrassa Spain
| | - Jaume Pujol
- Centre for Sensors, Instruments and Systems Development (CD6) Universitat Politècnica de Catalunya (UPC) Terrassa Spain
| | - Antoni Salvador
- Ophthalmology Service Hospital Universitari Mútua de Terrassa Terrassa Spain
| | - Meritxell Vilaseca
- Centre for Sensors, Instruments and Systems Development (CD6) Universitat Politècnica de Catalunya (UPC) Terrassa Spain
| |
Collapse
|
23
|
Halpaap D, Tiana-Alsina J, Vilaseca M, Masoller C. Experimental characterization of the speckle pattern at the output of a multimode optical fiber. OPTICS EXPRESS 2019; 27:27737-27744. [PMID: 31684536 DOI: 10.1364/oe.27.027737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 08/09/2019] [Indexed: 06/10/2023]
Abstract
Speckle patterns produced by coherent waves interfering with each other are undesirable in many imaging applications (for example, in laser projection systems) but on the other hand, they contain useful information that can be exploited (for example, for blood flow analysis or reconstruction of the object that generates the speckle). It is therefore important to understand how speckle can be enhanced or reduced by tailoring the coherence of laser light. Using a conventional semiconductor laser and a multimode optical fiber we study experimentally how the speckle pattern depends on the laser pump current and on the image acquisition settings. By varying the pump current from below to above the lasing threshold, and simultaneously tuning the image exposure time to compensate for the change in brightness, we find conditions that allow for recorded images with similar average intensity, but with speckle contrast (the standard deviation of the intensity over the average intensity) as low as 0.16, or as high as 0.99.
Collapse
|
24
|
Akondi V, Dubra A. Accounting for focal shift in the Shack-Hartmann wavefront sensor. OPTICS LETTERS 2019; 44:4151-4154. [PMID: 31465350 PMCID: PMC7535119 DOI: 10.1364/ol.44.004151] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Accepted: 07/13/2019] [Indexed: 05/18/2023]
Abstract
The Shack-Hartmann wavefront sensor samples a beam of light using an array of lenslets, each of which creates an image onto a pixelated sensor. These images translate from their nominal position by a distance proportional to the average wavefront slope over the corresponding lenslet. This principle fails in partially and/or non-uniformly illuminated lenslets when the lenslet array is focused to maximize peak intensity, leading to image centroid bias. Here, we show that this bias is due to the low Fresnel number of the lenslets, which shifts the diffraction focus away from the geometrical focus. We then demonstrate how the geometrical focus can be empirically found by minimizing the bias in partially illuminated lenslets.
Collapse
Affiliation(s)
- Vyas Akondi
- Byers Eye Institute, Stanford University, Palo Alto, California 94303, USA
| | - Alfredo Dubra
- Byers Eye Institute, Stanford University, Palo Alto, California 94303, USA
| |
Collapse
|
25
|
Suchkov N, Fernández EJ, Artal P. Wide-range adaptive optics visual simulator with a tunable lens. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2019; 36:722-730. [PMID: 31044998 DOI: 10.1364/josaa.36.000722] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
An adaptive optics visual simulator (AOVS) with an extended dioptric range was developed, allowing measuring and correcting aberrations in a majority of highly ametropic eyes. In the instrument, a tunable lens is used for defocus correction, while a liquid-crystal-on-silicon spatial light modulator is used for compensating or inducing any other aberration. The instrument incorporates a digital projector, which uses a micromirror array to display the stimuli. A motorized diaphragm enables operation for any physiological pupil size. A full description of the instrument and its calibration are provided, together with the results obtained in seven highly myopic subjects with refraction of -7.2±1.8 D (mean±SD). Refraction obtained with the instrument was compared to the standard refraction prescribed by trial lenses. When using the refraction obtained by the AOVS, the visual acuity (VA) exhibited an average increase of 0.21 (decimal scale). The visual impact of correcting high-order aberrations is presented in three subjects, whose VAs slightly improved with the correction. High myopes are able to benefit from the improved refraction assessment. The new instrument creates a possibility for a wide number of new experiments, especially for eyes exhibiting large refractive errors, where previous AO instruments failed to operate.
Collapse
|
26
|
Abstract
The double pass (DP) technique quantifies the optical quality of the eye by measuring its point spread function. The low reflectivity of the retina requires the use of a high-brightness, point-like illumination source, and thus, DP systems use laser diodes (LDs). However, LDs light produces speckle, and a low-cost solution to reduce speckle is to include a vibrating mirror in the beam path. With the goal of finding an all-optical solution, here we perform a comparative study of the amount of speckle produced by three semiconductor light sources: an LD, a light emitting diode (LED), and a superluminescent diode (SLED). We also compare the results with the speckle reduction that is obtained with a vibrating mirror. We find that the SLED is a good alternative to LD illumination, as the amount of speckle in the image is almost as low as that obtained with an LD and a vibrating mirror in the beam path.
Collapse
|
27
|
Burns SA, Elsner AE, Sapoznik KA, Warner RL, Gast TJ. Adaptive optics imaging of the human retina. Prog Retin Eye Res 2019; 68:1-30. [PMID: 30165239 PMCID: PMC6347528 DOI: 10.1016/j.preteyeres.2018.08.002] [Citation(s) in RCA: 126] [Impact Index Per Article: 25.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 08/22/2018] [Accepted: 08/24/2018] [Indexed: 12/18/2022]
Abstract
Adaptive Optics (AO) retinal imaging has provided revolutionary tools to scientists and clinicians for studying retinal structure and function in the living eye. From animal models to clinical patients, AO imaging is changing the way scientists are approaching the study of the retina. By providing cellular and subcellular details without the need for histology, it is now possible to perform large scale studies as well as to understand how an individual retina changes over time. Because AO retinal imaging is non-invasive and when performed with near-IR wavelengths both safe and easily tolerated by patients, it holds promise for being incorporated into clinical trials providing cell specific approaches to monitoring diseases and therapeutic interventions. AO is being used to enhance the ability of OCT, fluorescence imaging, and reflectance imaging. By incorporating imaging that is sensitive to differences in the scattering properties of retinal tissue, it is especially sensitive to disease, which can drastically impact retinal tissue properties. This review examines human AO retinal imaging with a concentration on the use of the Adaptive Optics Scanning Laser Ophthalmoscope (AOSLO). It first covers the background and the overall approaches to human AO retinal imaging, and the technology involved, and then concentrates on using AO retinal imaging to study the structure and function of the retina.
Collapse
Affiliation(s)
- Stephen A Burns
- 800E. Atwater S, School of Optometry, Indiana University, Bloomington, IN, United States.
| | - Ann E Elsner
- 800E. Atwater S, School of Optometry, Indiana University, Bloomington, IN, United States
| | - Kaitlyn A Sapoznik
- 800E. Atwater S, School of Optometry, Indiana University, Bloomington, IN, United States
| | - Raymond L Warner
- 800E. Atwater S, School of Optometry, Indiana University, Bloomington, IN, United States
| | - Thomas J Gast
- 800E. Atwater S, School of Optometry, Indiana University, Bloomington, IN, United States
| |
Collapse
|
28
|
South FA, Kurokawa K, Liu Z, Liu YZ, Miller DT, Boppart SA. Combined hardware and computational optical wavefront correction. BIOMEDICAL OPTICS EXPRESS 2018; 9:2562-2574. [PMID: 30258673 PMCID: PMC6154198 DOI: 10.1364/boe.9.002562] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2018] [Revised: 04/26/2018] [Accepted: 04/26/2018] [Indexed: 05/18/2023]
Abstract
In many optical imaging applications, it is necessary to overcome aberrations to obtain high-resolution images. Aberration correction can be performed by either physically modifying the optical wavefront using hardware components, or by modifying the wavefront during image reconstruction using computational imaging. Here we address a longstanding issue in computational imaging: photons that are not collected cannot be corrected. This severely restricts the applications of computational wavefront correction. Additionally, performance limitations of hardware wavefront correction leave many aberrations uncorrected. We combine hardware and computational correction to address the shortcomings of each method. Coherent optical backscattering data is collected using high-speed optical coherence tomography, with aberrations corrected at the time of acquisition using a wavefront sensor and deformable mirror to maximize photon collection. Remaining aberrations are corrected by digitally modifying the coherently-measured wavefront during imaging reconstruction. This strategy obtains high-resolution images with improved signal-to-noise ratio of in vivo human photoreceptor cells with more complete correction of ocular aberrations, and increased flexibility to image at multiple retinal depths, field locations, and time points. While our approach is not restricted to retinal imaging, this application is one of the most challenging for computational imaging due to the large aberrations of the dilated pupil, time-varying aberrations, and unavoidable eye motion. In contrast with previous computational imaging work, we have imaged single photoreceptors and their waveguide modes in fully dilated eyes with a single acquisition. Combined hardware and computational wavefront correction improves the image sharpness of existing adaptive optics systems, and broadens the potential applications of computational imaging methods.
Collapse
Affiliation(s)
- Fredrick A. South
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | | | - Zhuolin Liu
- School of Optometry, Indiana University, Bloomington, IN 47405, USA
| | - Yuan-Zhi Liu
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| | - Donald T. Miller
- School of Optometry, Indiana University, Bloomington, IN 47405, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
29
|
Mecê P, Jarosz J, Conan JM, Petit C, Grieve K, Paques M, Meimon S. Fixational eye movement: a negligible source of dynamic aberration. BIOMEDICAL OPTICS EXPRESS 2018; 9:717-727. [PMID: 29552407 PMCID: PMC5854073 DOI: 10.1364/boe.9.000717] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Revised: 12/20/2017] [Accepted: 12/20/2017] [Indexed: 05/06/2023]
Abstract
To evaluate the contribution of fixational eye movements to dynamic aberration, 50 healthy eyes were examined with an original custom-built Shack-Hartmann aberrometer, running at a temporal frequency of 236Hz, with 22 lenslets across a 5mm pupil, synchronized with a 236Hz pupil tracker. A comparison of the dynamic behavior of the first 21 Zernike modes (starting from defocus) with and without digital pupil stabilization, on a 3.4s sequence between blinks, showed that the contribution of fixational eye movements to dynamic aberration is negligible. Therefore we highlighted the fact that a pupil tracker coupled to an Adaptive Optics Ophthalmoscope is not essential to achieve diffraction-limited resolution.
Collapse
Affiliation(s)
- Pedro Mecê
- ONERA – the French Aerospace Lab, Châtillon,
France
- Quantel Medical, Cournon d’Auvergne,
France
| | - Jessica Jarosz
- ONERA – the French Aerospace Lab, Châtillon,
France
- Quantel Medical, Cournon d’Auvergne,
France
| | | | - Cyril Petit
- ONERA – the French Aerospace Lab, Châtillon,
France
| | - Kate Grieve
- Clinical Investigation Center-CIC 1423 INSERM, Quinze-Vingts National Eye Hospital,Paris,
France
- Institut de la Vision, Paris,
France
| | - Michel Paques
- Clinical Investigation Center-CIC 1423 INSERM, Quinze-Vingts National Eye Hospital,Paris,
France
- Institut de la Vision, Paris,
France
| | - Serge Meimon
- ONERA – the French Aerospace Lab, Châtillon,
France
| |
Collapse
|
30
|
Jiang Y, Wang Y, Zhang J, Chen X, Li L, Zhao H, Wang R, Dai Y. Dynamic changes in higher-order aberrations after correction of lower-order aberrations with adaptive optics in myopic and emmetropic eyes. APPLIED OPTICS 2018; 57:514-520. [PMID: 29400801 DOI: 10.1364/ao.57.000514] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2017] [Accepted: 12/18/2017] [Indexed: 06/07/2023]
Abstract
This study investigated the instantaneous changes of higher-order aberrations (HOAs) following lower-order aberrations (LOAs) correction with a closed-loop adaptive optics (AO) system in myopic and emmetropic eyes. Data were analyzed using generalized additive mixed models. Time-related changes in HOAs were modeled with two-piecewise linear regressions and were compared between myopic and emmetropic eyes. Both vertical coma and spherical aberrations shifted to the positive direction immediately after LOA correction. The fluctuations of the above values were significantly faster in myopic than in emmetropic eyes. Understanding these changes in HOAs following LOA correction may help in achieving better visual outcomes.
Collapse
|
31
|
de Paul AG, Sanchez RF, Issolio LA. Determination of the optimum double-pass image through focus operators. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2018; 35:20-27. [PMID: 29328088 DOI: 10.1364/josaa.35.000020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2017] [Accepted: 11/12/2017] [Indexed: 06/07/2023]
Abstract
A set of autofocus operators (AFO) are assessed for their ability to determine the optimal double-pass image as well as their potential to detect the focus lines and the disc of least confusion in astigmatic eyes. Eight AFO and three optical quality parameters (OQP) often used to analyze double-pass aerial images were considered. To quantify the discriminative power of each AFO and OQP, a maximum discrimination (MD) parameter was proposed. Double-pass images were obtained from an artificial eye with an induced astigmatism (Cylinder: -1 D, -0.75 D, 0.75 D, 1 D) and without astigmatism (Sphere: 0.1 D) and from 19 eyes of subjects with different refractions. The MD values for the autofocus operators Tenengrad variance and Gray level local variance were the highest for the artificial eye with and without astigmatism. In the case of astigmatic eyes, the discrimination of the focus lines with the autofocus operator Tenengrad variance was better than with OQP.
Collapse
|
32
|
Laslandes M, Salas M, Hitzenberger CK, Pircher M. Increasing the field of view of adaptive optics scanning laser ophthalmoscopy. BIOMEDICAL OPTICS EXPRESS 2017; 8:4811-4826. [PMID: 29188083 PMCID: PMC5695933 DOI: 10.1364/boe.8.004811] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Revised: 09/27/2017] [Accepted: 09/27/2017] [Indexed: 05/03/2023]
Abstract
An adaptive optics scanning laser ophthalmoscope (AO-SLO) set-up with two deformable mirrors (DM) is presented. It allows high resolution imaging of the retina on a 4°×4° field of view (FoV), considering a 7 mm pupil diameter at the entrance of the eye. Imaging on such a FoV, which is larger compared to classical AO-SLO instruments, is allowed by the use of the two DMs. The first DM is located in a plane that is conjugated to the pupil of the eye and corrects for aberrations that are constant in the FoV. The second DM is conjugated to a plane that is located ∼0.7 mm anterior to the retina. This DM corrects for anisoplanatism effects within the FoV. The control of the DMs is performed by combining the classical AO technique, using a Shack-Hartmann wave-front sensor, and sensorless AO, which uses a criterion characterizing the image quality. The retinas of four healthy volunteers were imaged in-vivo with the developed instrument. In order to assess the performance of the set-up and to demonstrate the benefits of the 2 DM configuration, the acquired images were compared with images taken in conventional conditions, on a smaller FoV and with only one DM. Moreover, an image of a larger patch of the retina was obtained by stitching of 9 images acquired with a 4°×4° FoV, resulting in a total FoV of 10°×10°. Finally, different retinal layers were imaged by shifting the focal plane.
Collapse
|
33
|
Whang WJ, Piao J, Yoo YS, Joo CK, Yoon G. The efficiency of aspheric intraocular lens according to biometric measurements. PLoS One 2017; 12:e0182606. [PMID: 29036175 PMCID: PMC5642893 DOI: 10.1371/journal.pone.0182606] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2016] [Accepted: 07/23/2017] [Indexed: 12/03/2022] Open
Abstract
Purpose To analyze internal spherical aberration in pseudophakic eyes that underwent aspheric intraocular lens (IOL) implantation, and to investigate the relationships between biometric data and the effectiveness of aspheric IOL implantation. Methods This retrospective study included 40 eyes of 40 patients who underwent implantation of an IOL having a negative spherical aberration of -0.20 μm (CT ASPHINA 509M; Carl Zeiss Meditec Inc., Germany). The IOLMaster (version 5.0; Carl Zeiss AG, Germany) was used for preoperative biometric measurements (axial length, anterior chamber depth, central corneal power) and the measurement of postoperative anterior chamber depth. The spherical aberrations were measured preoperatively and 3 months postoperatively using the iTrace (Tracey Technologies, Houston, TX, USA) at a pupil diameter of 5.0 mm. We investigated the relationships between preoperative biometric data and postoperative internal spherical aberration, and compared biometric measurements between 2 subgroups stratified according to internal spherical aberration (spherical aberration ≤ -0.06 μm vs. spherical aberration > -0.06 μm). Results The mean postoperative internal spherical aberration was -0.087 ± 0.063 μm. Preoperative axial length and residual total spherical aberration showed statistically significant correlations with internal spherical aberration (p = 0.041, 0.002). Preoperative axial length, postoperative anterior chamber depth, IOL power, and residual spherical aberration showed significant differences between the 2 subgroups stratified according to internal spherical aberration (p = 0.020, 0.029, 0.048, 0.041 respectively). Conclusion The corrective effect of an aspheric IOL is influenced by preoperative axial length and postoperative anterior chamber depth. Not only the amount of negative spherical aberration on the IOL surface but also the preoperative axial length should be considered to optimize spherical aberration after aspheric IOL implantation.
Collapse
Affiliation(s)
- Woong-Joo Whang
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Junjie Piao
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Young-Sik Yoo
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
| | - Choun-Ki Joo
- Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea
- * E-mail:
| | - Geunyoung Yoon
- Flaum Eye Institute, Center for Visual Science, The Institute of Optics, University of Rochester, Rochester, New York, United States of America
| |
Collapse
|
34
|
Zheng W, Wu Y, Winter P, Fischer R, Nogare DD, Hong A, McCormick C, Christensen R, Dempsey WP, Arnold DB, Zimmerberg J, Chitnis A, Sellers J, Waterman C, Shroff H. Adaptive optics improves multiphoton super-resolution imaging. Nat Methods 2017. [PMID: 28628128 DOI: 10.1038/nmeth.4337] [Citation(s) in RCA: 63] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
We improve multiphoton structured illumination microscopy using a nonlinear guide star to determine optical aberrations and a deformable mirror to correct them. We demonstrate our method on bead phantoms, cells in collagen gels, nematode larvae and embryos, Drosophila brain, and zebrafish embryos. Peak intensity is increased (up to 40-fold) and resolution recovered (up to 176 ± 10 nm laterally, 729 ± 39 nm axially) at depths ∼250 μm from the coverslip surface.
Collapse
Affiliation(s)
- Wei Zheng
- Section on High Resolution Optical Imaging, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA.,Research Laboratory for Biomedical Optics and Molecular Imaging, Shenzhen Key Laboratory for Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
| | - Yicong Wu
- Section on High Resolution Optical Imaging, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA
| | - Peter Winter
- Section on High Resolution Optical Imaging, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA
| | - Robert Fischer
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Damian Dalle Nogare
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, Maryland, USA
| | - Amy Hong
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Chad McCormick
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, Maryland, USA
| | - Ryan Christensen
- Section on High Resolution Optical Imaging, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA
| | - William P Dempsey
- Department of Biology, Section of Molecular and Computational Biology, University of Southern California, Los Angeles, California, USA
| | - Don B Arnold
- Department of Biology, Section of Molecular and Computational Biology, University of Southern California, Los Angeles, California, USA
| | - Joshua Zimmerberg
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, Maryland, USA
| | - Ajay Chitnis
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, Maryland, USA
| | - James Sellers
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Clare Waterman
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | - Hari Shroff
- Section on High Resolution Optical Imaging, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland, USA
| |
Collapse
|
35
|
Pircher M, Zawadzki RJ. Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:2536-2562. [PMID: 28663890 PMCID: PMC5480497 DOI: 10.1364/boe.8.002536] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 04/08/2017] [Accepted: 04/09/2017] [Indexed: 05/17/2023]
Abstract
In vivo imaging of the human retina with a resolution that allows visualization of cellular structures has proven to be essential to broaden our knowledge about the physiology of this precious and very complex neural tissue that enables the first steps in vision. Many pathologic changes originate from functional and structural alterations on a cellular scale, long before any degradation in vision can be noted. Therefore, it is important to investigate these tissues with a sufficient level of detail in order to better understand associated disease development or the effects of therapeutic intervention. Optical retinal imaging modalities rely on the optical elements of the eye itself (mainly the cornea and lens) to produce retinal images and are therefore affected by the specific arrangement of these elements and possible imperfections in curvature. Thus, aberrations are introduced to the imaging light and image quality is degraded. To compensate for these aberrations, adaptive optics (AO), a technology initially developed in astronomy, has been utilized. However, the axial sectioning provided by retinal AO-based fundus cameras and scanning laser ophthalmoscope instruments is limited to tens of micrometers because of the rather small available numerical aperture of the eye. To overcome this limitation and thus achieve much higher axial sectioning in the order of 2-5µm, AO has been combined with optical coherence tomography (OCT) into AO-OCT. This enabled for the first time in vivo volumetric retinal imaging with high isotropic resolution. This article summarizes the technical aspects of AO-OCT and provides an overview on its various implementations and some of its clinical applications. In addition, latest developments in the field, such as computational AO-OCT and wavefront sensor less AO-OCT, are covered.
Collapse
Affiliation(s)
- Michael Pircher
- Medical University of Vienna, Center for Medical Physics and Biomedical Engineering, Währinger Gürtel 18-20/4L, 1090 Vienna, Austria
| | - Robert J Zawadzki
- UC Davis RISE Eye-Pod Laboratory, Dept. of Cell Biology and Human Anatomy, University of California Davis, 4320 Tupper Hall, Davis, CA 95616, USA
- Vision Science and Advanced Retinal Imaging Laboratory (VSRI) and Department of Ophthalmology and Vision Science, UC Davis, 4860 Y Street, Ste. 2400, Sacramento, CA 95817, USA
| |
Collapse
|
36
|
Jarosz J, Mecê P, Conan JM, Petit C, Paques M, Meimon S. High temporal resolution aberrometry in a 50-eye population and implications for adaptive optics error budget. BIOMEDICAL OPTICS EXPRESS 2017; 8:2088-2105. [PMID: 28736657 PMCID: PMC5512730 DOI: 10.1364/boe.8.002088] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Revised: 01/31/2017] [Accepted: 02/01/2017] [Indexed: 05/05/2023]
Abstract
We formed a database gathering the wavefront aberrations of 50 healthy eyes measured with an original custom-built Shack-Hartmann aberrometer at a temporal frequency of 236 Hz, with 22 lenslets across a 7-mm diameter pupil, for a duration of 20 s. With this database, we draw statistics on the spatial and temporal behavior of the dynamic aberrations of the eye. Dynamic aberrations were studied on a 5-mm diameter pupil and on a 3.4 s sequence between blinks. We noted that, on average, temporal wavefront variance exhibits a n-2 power-law with radial order n and temporal spectra follow a f-1.5 power-law with temporal frequency f. From these statistics, we then extract guidelines for designing an adaptive optics system. For instance, we show the residual wavefront error evolution as a function of the number of corrected modes and of the adaptive optics loop frame rate. In particular, we infer that adaptive optics performance rapidly increases with the loop frequency up to 50 Hz, with gain being more limited at higher rates.
Collapse
Affiliation(s)
- Jessica Jarosz
- ONERA – the French Aerospace Lab, Châtillon,
France
- Quantel Medical, Cournon d’Auvergne,
France
| | - Pedro Mecê
- ONERA – the French Aerospace Lab, Châtillon,
France
- Quantel Medical, Cournon d’Auvergne,
France
| | | | - Cyril Petit
- ONERA – the French Aerospace Lab, Châtillon,
France
| | - Michel Paques
- CIC 1423, INSERM, Quinze-Vingts Hospital, Paris,
France
| | - Serge Meimon
- ONERA – the French Aerospace Lab, Châtillon,
France
| |
Collapse
|
37
|
Dong ZM, Wollstein G, Wang B, Schuman JS. Adaptive optics optical coherence tomography in glaucoma. Prog Retin Eye Res 2017; 57:76-88. [PMID: 27916682 PMCID: PMC5350038 DOI: 10.1016/j.preteyeres.2016.11.001] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Revised: 11/14/2016] [Accepted: 11/19/2016] [Indexed: 02/07/2023]
Abstract
Since the introduction of commercial optical coherence tomography (OCT) systems, the ophthalmic imaging modality has rapidly expanded and it has since changed the paradigm of visualization of the retina and revolutionized the management and diagnosis of neuro-retinal diseases, including glaucoma. OCT remains a dynamic and evolving imaging modality, growing from time-domain OCT to the improved spectral-domain OCT, adapting novel image analysis and processing methods, and onto the newer swept-source OCT and the implementation of adaptive optics (AO) into OCT. The incorporation of AO into ophthalmic imaging modalities has enhanced OCT by improving image resolution and quality, particularly in the posterior segment of the eye. Although OCT previously captured in-vivo cross-sectional images with unparalleled high resolution in the axial direction, monochromatic aberrations of the eye limit transverse or lateral resolution to about 15-20 μm and reduce overall image quality. In pairing AO technology with OCT, it is now possible to obtain diffraction-limited resolution images of the optic nerve head and retina in three-dimensions, increasing resolution down to a theoretical 3 μm3. It is now possible to visualize discrete structures within the posterior eye, such as photoreceptors, retinal nerve fiber layer bundles, the lamina cribrosa, and other structures relevant to glaucoma. Despite its limitations and barriers to widespread commercialization, the expanding role of AO in OCT is propelling this technology into clinical trials and onto becoming an invaluable modality in the clinician's arsenal.
Collapse
Affiliation(s)
- Zachary M Dong
- University of Pittsburgh Medical Center (UPMC) Eye Center, Eye and Ear Institute, Department of Ophthalmology, University of Pittsburgh School of Medicine, Ophthalmology and Visual Science Research Center, Pittsburgh, PA, United States.
| | - Gadi Wollstein
- New York University (NYU) Langone Eye Center, NYU Langone Medical Center, Department of Ophthalmology, NYU School of Medicine, New York, NY, United States.
| | - Bo Wang
- University of Pittsburgh Medical Center (UPMC) Eye Center, Eye and Ear Institute, Department of Ophthalmology, University of Pittsburgh School of Medicine, Ophthalmology and Visual Science Research Center, Pittsburgh, PA, United States.
| | - Joel S Schuman
- New York University (NYU) Langone Eye Center, NYU Langone Medical Center, Department of Ophthalmology, NYU School of Medicine, New York, NY, United States; Department of Electrical and Computer Engineering, New York University Tandon School of Engineering, Brooklyn, NY, United States.
| |
Collapse
|
38
|
|
39
|
Laslandes M, Salas M, Hitzenberger CK, Pircher M. Influence of wave-front sampling in adaptive optics retinal imaging. BIOMEDICAL OPTICS EXPRESS 2017; 8:1083-1100. [PMID: 28271004 PMCID: PMC5330566 DOI: 10.1364/boe.8.001083] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2016] [Revised: 01/11/2017] [Accepted: 01/12/2017] [Indexed: 05/03/2023]
Abstract
A wide range of sampling densities of the wave-front has been used in retinal adaptive optics (AO) instruments, compared to the number of corrector elements. We developed a model in order to characterize the link between number of actuators, number of wave-front sampling points and AO correction performance. Based on available data from aberration measurements in the human eye, 1000 wave-fronts were generated for the simulations. The AO correction performance in the presence of these representative aberrations was simulated for different deformable mirror and Shack Hartmann wave-front sensor combinations. Predictions of the model were experimentally tested through in vivo measurements in 10 eyes including retinal imaging with an AO scanning laser ophthalmoscope. According to our study, a ratio between wavefront sampling points and actuator elements of 2 is sufficient to achieve high resolution in vivo images of photoreceptors.
Collapse
|
40
|
Jonnal RS, Kocaoglu OP, Zawadzki RJ, Liu Z, Miller DT, Werner JS. A Review of Adaptive Optics Optical Coherence Tomography: Technical Advances, Scientific Applications, and the Future. Invest Ophthalmol Vis Sci 2016; 57:OCT51-68. [PMID: 27409507 PMCID: PMC4968917 DOI: 10.1167/iovs.16-19103] [Citation(s) in RCA: 93] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Accepted: 05/29/2016] [Indexed: 12/25/2022] Open
Abstract
PURPOSE Optical coherence tomography (OCT) has enabled "virtual biopsy" of the living human retina, revolutionizing both basic retina research and clinical practice over the past 25 years. For most of those years, in parallel, adaptive optics (AO) has been used to improve the transverse resolution of ophthalmoscopes to foster in vivo study of the retina at the microscopic level. Here, we review work done over the last 15 years to combine the microscopic transverse resolution of AO with the microscopic axial resolution of OCT, building AO-OCT systems with the highest three-dimensional resolution of any existing retinal imaging modality. METHODS We surveyed the literature to identify the most influential antecedent work, important milestones in the development of AO-OCT technology, its applications that have yielded new knowledge, research areas into which it may productively expand, and nascent applications that have the potential to grow. RESULTS Initial efforts focused on demonstrating three-dimensional resolution. Since then, many improvements have been made in resolution and speed, as well as other enhancements of acquisition and postprocessing techniques. Progress on these fronts has produced numerous discoveries about the anatomy, function, and optical properties of the retina. CONCLUSIONS Adaptive optics OCT continues to evolve technically and to contribute to our basic and clinical knowledge of the retina. Due to its capacity to reveal cellular and microscopic detail invisible to clinical OCT systems, it is an ideal companion to those instruments and has the demonstrable potential to produce images that can guide the interpretation of clinical findings.
Collapse
Affiliation(s)
- Ravi S. Jonnal
- Vision Science and Advanced Retinal Imaging Laboratory University of California-Davis, Sacramento, California, United States
| | - Omer P. Kocaoglu
- School of Optometry, Indiana University, Bloomington, Indiana, United States
| | - Robert J. Zawadzki
- Vision Science and Advanced Retinal Imaging Laboratory University of California-Davis, Sacramento, California, United States
| | - Zhuolin Liu
- School of Optometry, Indiana University, Bloomington, Indiana, United States
| | - Donald T. Miller
- School of Optometry, Indiana University, Bloomington, Indiana, United States
| | - John S. Werner
- Vision Science and Advanced Retinal Imaging Laboratory University of California-Davis, Sacramento, California, United States
| |
Collapse
|
41
|
Salas M, Drexler W, Levecq X, Lamory B, Ritter M, Prager S, Hafner J, Schmidt-Erfurth U, Pircher M. Multi-modal adaptive optics system including fundus photography and optical coherence tomography for the clinical setting. BIOMEDICAL OPTICS EXPRESS 2016; 7:1783-96. [PMID: 27231621 PMCID: PMC4871081 DOI: 10.1364/boe.7.001783] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Revised: 03/21/2016] [Accepted: 04/01/2016] [Indexed: 05/03/2023]
Abstract
We present a new compact multi-modal imaging prototype that combines an adaptive optics (AO) fundus camera with AO-optical coherence tomography (OCT) in a single instrument. The prototype allows acquiring AO fundus images with a field of view of 4°x4° and with a frame rate of 10fps. The exposure time of a single image is 10 ms. The short exposure time results in nearly motion artifact-free high resolution images of the retina. The AO-OCT mode allows acquiring volumetric data of the retina at 200kHz A-scan rate with a transverse resolution of ~4 µm and an axial resolution of ~5 µm. OCT imaging is acquired within a field of view of 2°x2° located at the central part of the AO fundus image. Recording of OCT volume data takes 0.8 seconds. The performance of the new system is tested in healthy volunteers and patients with retinal diseases.
Collapse
Affiliation(s)
- Matthias Salas
- Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| | - Wolfgang Drexler
- Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| | - Xavier Levecq
- Imagine Eyes, 18 Rue Charles de Gaulle 91400 Orsay, France
| | - Barbara Lamory
- Imagine Eyes, 18 Rue Charles de Gaulle 91400 Orsay, France
| | - Markus Ritter
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| | - Sonja Prager
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| | - Julia Hafner
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| | - Ursula Schmidt-Erfurth
- Department of Ophthalmology and Optometry, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| | - Michael Pircher
- Center of Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20 A-1090 Vienna, Austria
| |
Collapse
|
42
|
Kulcsár C, Raynaud HF, Garcia-Rissmann A. Eye-pupil displacement and prediction: effects on residual wavefront in adaptive optics retinal imaging. BIOMEDICAL OPTICS EXPRESS 2016; 7:1051-73. [PMID: 27231607 PMCID: PMC4869933 DOI: 10.1364/boe.7.001051] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Revised: 01/12/2016] [Accepted: 01/12/2016] [Indexed: 05/22/2023]
Abstract
This paper studies the effect of pupil displacements on the best achievable performance of retinal imaging adaptive optics (AO) systems, using 52 trajectories of horizontal and vertical displacements sampled at 80 Hz by a pupil tracker (PT) device on 13 different subjects. This effect is quantified in the form of minimal root mean square (rms) of the residual phase affecting image formation, as a function of the delay between PT measurement and wavefront correction. It is shown that simple dynamic models identified from data can be used to predict horizontal and vertical pupil displacements with greater accuracy (in terms of average rms) over short-term time horizons. The potential impact of these improvements on residual wavefront rms is investigated. These results allow to quantify the part of disturbances corrected by retinal imaging systems that are caused by relative displacements of an otherwise fixed or slowy-varying subject-dependent aberration. They also suggest that prediction has a limited impact on wavefront rms and that taking into account PT measurements in real time improves the performance of AO retinal imaging systems.
Collapse
Affiliation(s)
- Caroline Kulcsár
- Laboratoire Charles Fabry – Institut d’Optique Graduate School – CNRS, Universit Paris-Saclay,
France
| | - Henri-François Raynaud
- Laboratoire Charles Fabry – Institut d’Optique Graduate School – CNRS, Universit Paris-Saclay,
France
| | - Aurea Garcia-Rissmann
- Laboratório Nacional de Astrofísica/MCTI, Brazil – Previously with University Paris 13,
France
| |
Collapse
|
43
|
Bueno JM, Pérez G, Benito A, Artal P. Impact of scatter on double-pass image quality and contrast sensitivity measured with a single instrument. BIOMEDICAL OPTICS EXPRESS 2015; 6:4841-4849. [PMID: 26713198 PMCID: PMC4679258 DOI: 10.1364/boe.6.004841] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 11/11/2015] [Accepted: 11/12/2015] [Indexed: 05/31/2023]
Abstract
We compared objective Double-Pass (DP) image quality data with subjective visual parameters measured within the same modified instrument for different amounts of scatter. The original DP imaging channel of a clinical instrument was maintained intact and two additional channels were included, one for visual testing and another for tear film (TF) imaging by using a retro-illumination technique. Contrast sensitivity (CS) was compared with measurements of the Objective Scattering Index (OSI) obtained from DP retinal images corresponding to different scatter levels induced by pre-defined filters. OSI values were correlated with the change in CS for different spatial frequencies measured with the same instrument. Since TF and DP images were recorded at the same rate, this provided additional information about the dynamic spatial stability of the tear film. This new DP instrument has been proven to provide accuracy and repeatability, and to be suitable for clinical diagnosis, with a complete evaluation of the eye's performance by a simultaneous objective and subjective assessment under the same experimental conditions.
Collapse
|
44
|
Yu Y, Zhang T, Meadway A, Wang X, Zhang Y. High-speed adaptive optics for imaging of the living human eye. OPTICS EXPRESS 2015; 23:23035-52. [PMID: 26368408 PMCID: PMC4646518 DOI: 10.1364/oe.23.023035] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Revised: 08/10/2015] [Accepted: 08/10/2015] [Indexed: 05/18/2023]
Abstract
The discovery of high frequency temporal fluctuation of human ocular wave aberration dictates the necessity of high speed adaptive optics (AO) correction for high resolution retinal imaging. We present a high speed AO system for an experimental adaptive optics scanning laser ophthalmoscope (AOSLO). We developed a custom high speed Shack-Hartmann wavefront sensor and maximized the wavefront detection speed based upon a trade-off among the wavefront spatial sampling density, the dynamic range, and the measurement sensitivity. We examined the temporal dynamic property of the ocular wavefront under the AOSLO imaging condition and improved the dual-thread AO control strategy. The high speed AO can be operated with a closed-loop frequency up to 110 Hz. Experiment results demonstrated that the high speed AO system can provide improved compensation for the wave aberration up to 30 Hz in the living human eye.
Collapse
Affiliation(s)
- Yongxin Yu
- Department of Ophthalmology, University of Alabama at Birmingham, 1670 University Boulevard, Birmingham, AL 35294, USA
- School of Computer Science and Technology, Tianjin University, Tianjin 300072, China
| | - Tianjiao Zhang
- Department of Biomedical Engineering, University of Alabama at Birmingham, 1825 University Boulevard, Birmingham, AL 35294, USA
| | - Alexander Meadway
- Department of Ophthalmology, University of Alabama at Birmingham, 1670 University Boulevard, Birmingham, AL 35294, USA
| | - Xiaolin Wang
- Department of Ophthalmology, University of Alabama at Birmingham, 1670 University Boulevard, Birmingham, AL 35294, USA
| | - Yuhua Zhang
- Department of Ophthalmology, University of Alabama at Birmingham, 1670 University Boulevard, Birmingham, AL 35294, USA
- Department of Biomedical Engineering, University of Alabama at Birmingham, 1825 University Boulevard, Birmingham, AL 35294, USA
| |
Collapse
|
45
|
Zhou X, Bedggood P, Bui B, Nguyen CT, He Z, Metha A. Contrast-based sensorless adaptive optics for retinal imaging. BIOMEDICAL OPTICS EXPRESS 2015; 6:3577-95. [PMID: 26417525 PMCID: PMC4574681 DOI: 10.1364/boe.6.003577] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2015] [Revised: 08/13/2015] [Accepted: 08/18/2015] [Indexed: 05/05/2023]
Abstract
Conventional adaptive optics ophthalmoscopes use wavefront sensing methods to characterize ocular aberrations for real-time correction. However, there are important situations in which the wavefront sensing step is susceptible to difficulties that affect the accuracy of the correction. To circumvent these, wavefront sensorless adaptive optics (or non-wavefront sensing AO; NS-AO) imaging has recently been developed and has been applied to point-scanning based retinal imaging modalities. In this study we show, for the first time, contrast-based NS-AO ophthalmoscopy for full-frame in vivo imaging of human and animal eyes. We suggest a robust image quality metric that could be used for any imaging modality, and test its performance against other metrics using (physical) model eyes.
Collapse
|
46
|
Charman WN, Heron G. Microfluctuations in accommodation: an update on their characteristics and possible role. Ophthalmic Physiol Opt 2015; 35:476-99. [DOI: 10.1111/opo.12234] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2015] [Accepted: 07/23/2015] [Indexed: 11/30/2022]
Affiliation(s)
- W Neil Charman
- Faculty of Life Sciences; University of Manchester; Manchester UK
| | - Gordon Heron
- Vision Sciences; Glasgow Caledonian University; Glasgow UK
| |
Collapse
|
47
|
Otero C, Vilaseca M, Arjona M, Martínez-Roda JA, Pujol J. Repeatability of aberrometric measurements with a new instrument for vision analysis based on adaptive optics. J Refract Surg 2015; 31:188-94. [PMID: 25751836 DOI: 10.3928/1081597x-20150224-03] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2014] [Accepted: 01/19/2015] [Indexed: 11/20/2022]
Abstract
PURPOSE To evaluate intersession and intrasession repeatability of aberration data obtained with a new visual simulator based on adaptive optics, which includes a Hartmann-Shack aberrometer (Adaptive Optics Vision Analyzer; Voptica S.L., Murcia, Spain). METHODS Thirty-one healthy right eyes were included in the study. To evaluate intrasession repeatability, three consecutive measurements without repositioning the patient or realigning the eye were obtained. Intersession repeatability was evaluated in three sessions. Aberrometric data computed from the second to the fifth order for a 4-mm pupil were used. Statistical analysis included the repeated measures analysis of variance (or the Wilcoxon signed rank test), the coefficient of repeatability, the Bland-Altman method, and the intraclass correlation coefficient. RESULTS No significant differences in the intrasession and intersession repeatability analysis for any of the parameters (P > .05) were found, suggesting a consistent variability of the instrument over time. Similar coefficient of repeatability values were obtained in the three sessions. The Bland-Altman analysis confirmed differences close to zero and the variations were independent of the mean within and between sessions. The intersession intraclass correlation coefficient values were generally above 0.75, suggesting moderate to high repeatability. However, some exceptions were found in the intrasession analysis. CONCLUSIONS The findings suggest that the new instrument provides consistent and repeatable aberrometric data. It is therefore a suitable tool to perform consistent and repeatable visual simulations.
Collapse
|
48
|
Contrast sensitivity function after correcting residual wavefront aberrations during RGP lens wear. Optom Vis Sci 2015; 91:1271-7. [PMID: 24770353 DOI: 10.1097/opx.0000000000000253] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE To investigate the effect on the contrast sensitivity function (CSF) of correcting the residual wavefront aberrations in myopic and keratoconic subjects wearing rigid gas permeable (RGP) contact lenses. METHODS Seventeen eyes of 16 myopic subjects and 20 eyes of 19 keratoconic subjects were included in this study. All eyes were habitually corrected with RGP lenses. The residual aberrations of the RGP lens-wearing eyes were compensated by an adaptive optics (AO) system. The contrast sensitivities were measured through a 4-mm artificial pupil at spatial frequencies of 2, 4, 8, 16, and 32 cycles per degree (cpd) during RGP lens wear for the myopic and keratoconic groups, respectively. The CSF measurements were repeated with and without AO correction. Comparisons of contrast sensitivity at all spatial frequencies with and without AO correction were performed respectively for the myopic and keratoconic groups during RGP lens wear. RESULTS In the myopic RGP lens-wearing group, the differences in contrast sensitivity at each spatial frequency, with and without AO correction, were not significant (all p values > 0.05). In the keratoconic RGP lens-wearing group, the contrast sensitivities at all spatial frequencies with AO correction were higher than those without AO correction, but differences only at the low (2 cpd) and intermediate (4, 8, and 16 cpd) spatial frequencies were significant (p = 0.039, 0.005, 0.001, and 0.007). CONCLUSIONS The residual aberrations significantly reduced the contrast sensitivities at low and intermediate spatial frequencies for keratoconic RGP lens-wearing eyes but did not have any effect on the CSF for the myopic RGP lens-wearing eyes. Developing techniques that could more completely correct the wavefront aberrations may improve visual performance in keratoconus.
Collapse
|
49
|
Malacara-Hernández D, Malacara-Doblado D. What is a Hartmann test? APPLIED OPTICS 2015; 54:2296-2301. [PMID: 25968514 DOI: 10.1364/ao.54.002296] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/22/2014] [Accepted: 02/06/2015] [Indexed: 06/04/2023]
Abstract
In this paper we will review some of the many different practical arrangements that have been obtained to measure the transversal aberrations of optical systems based on the odd and vulnerable Hartmann test. There are many optical testing configurations that apparently are not related to the original Hartmann test. However, they are really the same thing and can be considered just a variation of the same basic arrangement, as will be described here.
Collapse
|
50
|
Radhakrishnan A, Sawides L, Dorronsoro C, Peli E, Marcos S. Single neural code for blur in subjects with different interocular optical blur orientation. J Vis 2015; 15:15. [PMID: 26114678 PMCID: PMC4484355 DOI: 10.1167/15.8.15] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2014] [Accepted: 05/11/2015] [Indexed: 11/24/2022] Open
Abstract
The ability of the visual system to compensate for differences in blur orientation between eyes is not well understood. We measured the orientation of the internal blur code in both eyes of the same subject monocularly by presenting pairs of images blurred with real ocular point spread functions (PSFs) of similar blur magnitude but varying in orientations. Subjects assigned a level of confidence to their selection of the best perceived image in each pair. Using a classification-images-inspired paradigm and applying a reverse correlation technique, a classification map was obtained from the weighted averages of the PSFs, representing the internal blur code. Positive and negative neural PSFs were obtained from the classification map, representing the neural blur for best and worse perceived blur, respectively. The neural PSF was found to be highly correlated in both eyes, even for eyes with different ocular PSF orientations (rPos = 0.95; rNeg = 0.99; p < 0.001). We found that in subjects with similar and with different ocular PSF orientations between eyes, the orientation of the positive neural PSF was closer to the orientation of the ocular PSF of the eye with the better optical quality (average difference was ∼10°), while the orientation of the positive and negative neural PSFs tended to be orthogonal. These results suggest a single internal code for blur with orientation driven by the orientation of the optical blur of the eye with better optical quality.
Collapse
|