1
|
Tian L, Chen F, Macosko EZ. The expanding vistas of spatial transcriptomics. Nat Biotechnol 2023; 41:773-782. [PMID: 36192637 PMCID: PMC10091579 DOI: 10.1038/s41587-022-01448-2] [Citation(s) in RCA: 109] [Impact Index Per Article: 109.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 07/26/2022] [Indexed: 11/09/2022]
Abstract
The formation and maintenance of tissue integrity requires complex, coordinated activities by thousands of genes and their encoded products. Until recently, transcript levels could only be quantified for a few genes in tissues, but advances in DNA sequencing, oligonucleotide synthesis and fluorescence microscopy have enabled the invention of a suite of spatial transcriptomics technologies capable of measuring the expression of many, or all, genes in situ. These technologies have evolved rapidly in sensitivity, multiplexing and throughput. As such, they have enabled the determination of the cell-type architecture of tissues, the querying of cell-cell interactions and the monitoring of molecular interactions between tissue components. The rapidly evolving spatial genomics landscape will enable generalized high-throughput genomic measurements and perturbations to be performed in the context of tissues. These advances will empower hypothesis generation and biological discovery and bridge the worlds of tissue biology and genomics.
Collapse
Affiliation(s)
- Luyi Tian
- Broad Institute of Harvard and MIT, Cambridge, MA, USA
| | - Fei Chen
- Broad Institute of Harvard and MIT, Cambridge, MA, USA.
- Harvard Stem Cell and Regenerative Biology, Cambridge, MA, USA.
| | - Evan Z Macosko
- Broad Institute of Harvard and MIT, Cambridge, MA, USA.
- Department of Psychiatry, Massachusetts General Hospital, Boston, MA, USA.
| |
Collapse
|
2
|
sCMOS Noise-Corrected Superresolution Reconstruction Algorithm for Structured Illumination Microscopy. PHOTONICS 2022. [DOI: 10.3390/photonics9030172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Structured illumination microscopy (SIM) is widely applied due to its high temporal and spatial resolution imaging ability. sCMOS cameras are often used in SIM due to their superior sensitivity, resolution, field of view, and frame rates. However, the unique single-pixel-dependent readout noise of sCMOS cameras may lead to SIM reconstruction artefacts and affect the accuracy of subsequent statistical analysis. We first established a nonuniform sCMOS noise model to address this issue, which incorporates the single-pixel-dependent offset, gain, and variance based on the SIM imaging process. The simulation indicates that the sCMOS pixel-dependent readout noise causes artefacts in the reconstructed SIM superresolution (SR) image. Thus, we propose a novel sCMOS noise-corrected SIM reconstruction algorithm derived from the imaging model, which can effectively suppress the sCMOS noise-related reconstruction artefacts and improve the signal-to-noise ratio (SNR).
Collapse
|
3
|
Fairlamb MS, Whitaker AM, Bain FE, Spies M, Freudenthal BD. Construction of a Three-Color Prism-Based TIRF Microscope to Study the Interactions and Dynamics of Macromolecules. BIOLOGY 2021; 10:biology10070571. [PMID: 34201434 PMCID: PMC8301196 DOI: 10.3390/biology10070571] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 06/08/2021] [Accepted: 06/15/2021] [Indexed: 02/05/2023]
Abstract
Simple Summary Prism-based single-molecule total internal reflection fluorescence (prismTIRF) microscopes are excellent tools for studying macromolecular dynamics and interactions. Here, we provide an easy-to-follow guide for the design, assembly, and operation of a three-color prismTIRF microscope using commercially available components with the hope of assisting those who aim to implement TIRF imaging techniques in their laboratory. Abstract Single-molecule total internal reflection fluorescence (TIRF) microscopy allows for the real-time visualization of macromolecular dynamics and complex assembly. Prism-based TIRF microscopes (prismTIRF) are relatively simple to operate and can be easily modulated to fit the needs of a wide variety of experimental applications. While building a prismTIRF microscope without expert assistance can pose a significant challenge, the components needed to build a prismTIRF microscope are relatively affordable and, with some guidance, the assembly can be completed by a determined novice. Here, we provide an easy-to-follow guide for the design, assembly, and operation of a three-color prismTIRF microscope which can be utilized for the study of macromolecular complexes, including the multi-component protein–DNA complexes responsible for DNA repair, replication, and transcription. Our hope is that this article can assist laboratories that aspire to implement single-molecule TIRF techniques, and consequently expand the application of this technology.
Collapse
Affiliation(s)
- Max S. Fairlamb
- Department of Biochemistry and Molecular Biology and Department of Cancer Biology, University of Kansas Medical Center, Kansas City, KS 66160, USA; (M.S.F.); (A.M.W.)
| | - Amy M. Whitaker
- Department of Biochemistry and Molecular Biology and Department of Cancer Biology, University of Kansas Medical Center, Kansas City, KS 66160, USA; (M.S.F.); (A.M.W.)
| | - Fletcher E. Bain
- Department of Biochemistry and Molecular Biology, University of Iowa Carver College of Medicine, 51 Newton Road, Iowa City, IA 52242, USA; (F.E.B.); (M.S.)
| | - Maria Spies
- Department of Biochemistry and Molecular Biology, University of Iowa Carver College of Medicine, 51 Newton Road, Iowa City, IA 52242, USA; (F.E.B.); (M.S.)
| | - Bret D. Freudenthal
- Department of Biochemistry and Molecular Biology and Department of Cancer Biology, University of Kansas Medical Center, Kansas City, KS 66160, USA; (M.S.F.); (A.M.W.)
- Correspondence:
| |
Collapse
|
4
|
Nandagiri A, Gaikwad AS, Potter DL, Nosrati R, Soria J, O'Bryan MK, Jadhav S, Prabhakar R. Flagellar energetics from high-resolution imaging of beating patterns in tethered mouse sperm. eLife 2021; 10:62524. [PMID: 33929317 PMCID: PMC8159377 DOI: 10.7554/elife.62524] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 04/29/2021] [Indexed: 01/07/2023] Open
Abstract
We demonstrate a technique for investigating the energetics of flagella or cilia. We record the planar beating of tethered mouse sperm at high resolution. Beating waveforms are reconstructed using proper orthogonal decomposition of the centerline tangent-angle profiles. Energy conservation is employed to obtain the mechanical power exerted by the dynein motors from the observed kinematics. A large proportion of the mechanical power exerted by the dynein motors is dissipated internally by the motors themselves. There could also be significant dissipation within the passive structures of the flagellum. The total internal dissipation is considerably greater than the hydrodynamic dissipation in the aqueous medium outside. The net power input from the dynein motors in sperm from Crisp2-knockout mice is significantly smaller than in wildtype samples, indicating that ion-channel regulation by cysteine-rich secretory proteins controls energy flows powering the axoneme.
Collapse
Affiliation(s)
- Ashwin Nandagiri
- IITB-Monash Research Academy, Mumbai, India.,Department of Chemical Engineering, Indian Institute of Technology Bombay, Mumbai, India.,Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Australia
| | | | - David L Potter
- Monash Micro-Imaging, Monash University, Clayton, Australia
| | - Reza Nosrati
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Australia
| | - Julio Soria
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Australia
| | - Moira K O'Bryan
- School of BioSciences, University of Melbourne, Parkville, Australia
| | - Sameer Jadhav
- Department of Chemical Engineering, Indian Institute of Technology Bombay, Mumbai, India
| | - Ranganathan Prabhakar
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton, Australia
| |
Collapse
|
5
|
Badugu R, Szmacinski H, Reece EA, Jeng BH, Lakowicz JR. Sodium-Sensitive Contact Lens for Diagnostics of Ocular Pathologies. SENSORS AND ACTUATORS. B, CHEMICAL 2021; 331:129434. [PMID: 33551571 PMCID: PMC7861470 DOI: 10.1016/j.snb.2021.129434] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The ability to measure all the electrolyte concentrations in tears would be valuable in ophthalmology for research and diagnosis of dry eye disease (DED) and other ocular pathologies. However, tear samples are difficult to collect and analyze because the total volume is small and the chemical composition changes rapidly. Measurements of electrolytes in tears is challenging because typical clinical assays for proteins and other biomarkers cannot be used to detect ion concentrations tears. Here, we report the contact lens which is sensitive to sodium ion (Na+), one of the dominant electrolytes in tears. The Na ions in tears is diagnostic for DED. Three sodium-sensitive fluorophores (SG-C16, SG-LPE and SG-PL) were synthesized by derivatizing the sodium green with 1-hexadecyl amine, 1-oleoyl-2-hydroxy-sn-glycero-3-phosphoethanolamine or poly-L-lysine, respectively. These probes were bound to modern silicone hydrogel (SiHG) contact lens, Biofinity from Cooper Vision. Doped lenses were tested for sodium ion dependent spectral properties of probes within the contact lens. The probes displayed changes in intensity and lifetime in response to Na+ concentration, were completely reversible, no significant probe wash-out from the lenses, were not affected by proteins in tears and were not removed after repeated washing. These results are the first step to our long-term goal, which is a lens sensitive to all the electrolytes in tears. We presented design, synthesis and implementation of three new sodium sensitive probes within a silicon hydrogel lens. Contact lenses to measure the other electrolytes in tears can be developed using the same approach by synthesis and testing of new ion-sensitive fluorophores.
Collapse
Affiliation(s)
- Ramachandram Badugu
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology University of Maryland School of Medicine, 725 West Lombard St., Baltimore, MD 21201, USA
| | - Henryk Szmacinski
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology University of Maryland School of Medicine, 725 West Lombard St., Baltimore, MD 21201, USA
| | - E Albert Reece
- Department of Obstetrics, Gynecology and Reproductive Sciences, University of Maryland School of Medicine, 655 W. Baltimore Street, Baltimore, MD 21201, USA
- Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 655 W. Baltimore Street, Baltimore, Md 21201, USA
| | - Bennie H Jeng
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, 419 W. Redwood Street, Baltimore, Md 21201, USA
| | - Joseph R Lakowicz
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology University of Maryland School of Medicine, 725 West Lombard St., Baltimore, MD 21201, USA
| |
Collapse
|
6
|
Zhang Z, Wang Y, Piestun R, Huang ZL. Characterizing and correcting camera noise in back-illuminated sCMOS cameras. OPTICS EXPRESS 2021; 29:6668-6690. [PMID: 33726183 DOI: 10.1364/oe.418684] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2020] [Accepted: 02/08/2021] [Indexed: 06/12/2023]
Abstract
With promising properties of fast imaging speed, large field-of-view, relative low cost and many others, back-illuminated sCMOS cameras have been receiving intensive attention for low light level imaging in the past several years. However, due to the pixel-to-pixel difference of camera noise (called noise non-uniformity) in sCMOS cameras, researchers may hesitate to use them in some application fields, and sometimes wonder whether they should optimize the noise non-uniformity of their sCMOS cameras before using them in a specific application scenario. In this paper, we systematically characterize the impact of different types of sCMOS noise on image quality and perform corrections to these types of sCMOS noise using three representative algorithms (PURE, NCS and MLEsCMOS). We verify that it is possible to use appropriate correction methods to push the non-uniformity of major types of camera noise, including readout noise, offset, and photon response, to a satisfactory level for conventional microscopy and single molecule localization microscopy. We further find out that, after these corrections, global read noise becomes a major concern that limits the imaging performance of back-illuminated sCMOS cameras. We believe this study provides new insights into the understanding of camera noise in back-illuminated sCMOS cameras, and also provides useful information for future development of this promising camera technology.
Collapse
|
7
|
Fast and accurate sCMOS noise correction for fluorescence microscopy. Nat Commun 2020; 11:94. [PMID: 31901080 PMCID: PMC6941997 DOI: 10.1038/s41467-019-13841-8] [Citation(s) in RCA: 65] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Accepted: 11/29/2019] [Indexed: 12/12/2022] Open
Abstract
The rapid development of scientific CMOS (sCMOS) technology has greatly advanced optical microscopy for biomedical research with superior sensitivity, resolution, field-of-view, and frame rates. However, for sCMOS sensors, the parallel charge-voltage conversion and different responsivity at each pixel induces extra readout and pattern noise compared to charge-coupled devices (CCD) and electron-multiplying CCD (EM-CCD) sensors. This can produce artifacts, deteriorate imaging capability, and hinder quantification of fluorescent signals, thereby compromising strategies to reduce photo-damage to live samples. Here, we propose a content-adaptive algorithm for the automatic correction of sCMOS-related noise (ACsN) for fluorescence microscopy. ACsN combines camera physics and layered sparse filtering to significantly reduce the most relevant noise sources in a sCMOS sensor while preserving the fine details of the signal. The method improves the camera performance, enabling fast, low-light and quantitative optical microscopy with video-rate denoising for a broad range of imaging conditions and modalities. Scientific complementary metal-oxide semiconductor (sCMOS) cameras have advanced the imaging field, but they often suffer from additional noise compared to CCD sensors. Here the authors present a content-adaptive algorithm for the automatic correction of sCMOS-related noise for fluorescence microscopy.
Collapse
|
8
|
Kogel A, Kalwa H, Urban N, Schaefer M. Artifact-free objective-type multicolor total internal reflection fluorescence microscopy with light-emitting diode light sources-Part I. JOURNAL OF BIOPHOTONICS 2019; 12:e201900033. [PMID: 31148410 DOI: 10.1002/jbio.201900033] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2019] [Revised: 04/07/2019] [Accepted: 05/29/2019] [Indexed: 06/09/2023]
Abstract
Total internal reflection fluorescence excitation (TIRF) microscopy allows the selective observation of fluorescent molecules in immediate proximity to an interface between different refractive indices. Objective-type or prism-less TIRF excitation is typically achieved with laser light sources. We here propose a simple, yet optically advantageous light-emitting diode (LED)-based implementation of objective-type TIRF (LED-TIRF). The proposed LED-TIRF condenser is affordable and easy to set up at any epifluorescence microscope to perform multicolor TIRF and/or combined TIRF-epifluorescence imaging with even illumination of the entire field of view. Electrical control of LED light sources replaces mechanical shutters or optical modulators. LED-TIRF microscopy eliminates safety burdens that are associated with laser sources, offers favorable instrument lifetime and stability without active cooling. The non-coherent light source and the type of projection eliminate interference fringing and local scattering artifacts that are associated with conventional laser-TIRF. Unlike azimuthal spinning laser-TIRF, LED-TIRF does not require synchronization between beam rotation and the camera and can be monitored with either global or rolling shutter cameras. Typical implementations, such as live cell multicolor imaging in TIRF and epifluorescence of imaging of short-lived, localized translocation events of a Ca2+ -sensitive protein kinase C α fusion protein are demonstrated.
Collapse
Affiliation(s)
- Alexander Kogel
- Rudolf-Boehm-Institut für Pharmakologie und Toxikologie, Universität Leipzig, Leipzig, Germany
| | - Hermann Kalwa
- Rudolf-Boehm-Institut für Pharmakologie und Toxikologie, Universität Leipzig, Leipzig, Germany
| | - Nicole Urban
- Rudolf-Boehm-Institut für Pharmakologie und Toxikologie, Universität Leipzig, Leipzig, Germany
| | - Michael Schaefer
- Rudolf-Boehm-Institut für Pharmakologie und Toxikologie, Universität Leipzig, Leipzig, Germany
| |
Collapse
|
9
|
Markman A, O'Connor T, Hotaka H, Ohsuka S, Javidi B. Three-dimensional integral imaging in photon-starved environments with high-sensitivity image sensors. OPTICS EXPRESS 2019; 27:26355-26368. [PMID: 31674519 DOI: 10.1364/oe.27.026355] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2019] [Accepted: 08/13/2019] [Indexed: 06/10/2023]
Abstract
Imaging in poorly illuminated environments using three-dimensional (3D) imaging with passive imaging sensors that operate in the visible spectrum is a formidable task due to the low number of photons detected. 3D integral imaging, which integrates multiple two-dimensional perspectives, is expected to perform well in the presence of noise, as well as statistical fluctuation in the detected number of photons. In this paper, we present an investigation of 3D integral imaging in low-light-level conditions, where as low as a few photons and as high as several tens of photons are detected on average per pixel. In the experimental verification, we use an electron multiplying charge-coupled device (EM-CCD) and a scientific complementary metal-oxide-semiconductor (sCMOS) camera. For the EM-CCD, a theoretical model for the probability distribution of the pixel values is derived, then fitted with the experimental data to determine the camera parameters. Likewise, pixelwise calibration is performed on the sCMOS to determine the camera parameters for further analysis. Theoretical derivation of the expected signal-to-noise-ratio is provided for each image sensor and corroborated by the experimental findings. Further comparison between the cameras includes analysis of the contrast-to-noise ratio (CNR) as well as the perception-based image quality estimator (PIQE). Improvement of image quality metrics in the 3D reconstructed images is successfully confirmed compared with those of the 2D images. To the best of our knowledge, this is the first experimental report of low-light-level 3D integral imaging with as little as a few photons detected per pixel on average to improve scene visualization including occlusion removal from the scene.
Collapse
|
10
|
cellSTORM-Cost-effective super-resolution on a cellphone using dSTORM. PLoS One 2019; 14:e0209827. [PMID: 30625170 PMCID: PMC6326471 DOI: 10.1371/journal.pone.0209827] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Accepted: 12/12/2018] [Indexed: 01/12/2023] Open
Abstract
High optical resolution in microscopy usually goes along with costly hardware components, such as lenses, mechanical setups and cameras. Several studies proved that Single Molecular Localization Microscopy can be made affordable, relying on off-the-shelf optical components and industry grade CMOS cameras. Recent technological advantages have yielded consumer-grade camera devices with surprisingly good performance. The camera sensors of smartphones have benefited of this development. Combined with computing power smartphones provide a fantastic opportunity for “imaging on a budget”. Here we show that a consumer cellphone is capable of optical super-resolution imaging by (direct) Stochastic Optical Reconstruction Microscopy (dSTORM), achieving optical resolution better than 80 nm. In addition to the use of standard reconstruction algorithms, we used a trained image-to-image generative adversarial network (GAN) to reconstruct video sequences under conditions where traditional algorithms provide sub-optimal localization performance directly on the smartphone. We believe that “cellSTORM” paves the way to make super-resolution microscopy not only affordable but available due to the ubiquity of cellphone cameras.
Collapse
|
11
|
Klein HL, Ang KKH, Arkin MR, Beckwitt EC, Chang YH, Fan J, Kwon Y, Morten MJ, Mukherjee S, Pambos OJ, El Sayyed H, Thrall ES, Vieira-da-Rocha JP, Wang Q, Wang S, Yeh HY, Biteen JS, Chi P, Heyer WD, Kapanidis AN, Loparo JJ, Strick TR, Sung P, Van Houten B, Niu H, Rothenberg E. Guidelines for DNA recombination and repair studies: Mechanistic assays of DNA repair processes. MICROBIAL CELL 2019; 6:65-101. [PMID: 30652106 PMCID: PMC6334232 DOI: 10.15698/mic2019.01.665] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Genomes are constantly in flux, undergoing changes due to recombination, repair and mutagenesis. In vivo, many of such changes are studies using reporters for specific types of changes, or through cytological studies that detect changes at the single-cell level. Single molecule assays, which are reviewed here, can detect transient intermediates and dynamics of events. Biochemical assays allow detailed investigation of the DNA and protein activities of each step in a repair, recombination or mutagenesis event. Each type of assay is a powerful tool but each comes with its particular advantages and limitations. Here the most commonly used assays are reviewed, discussed, and presented as the guidelines for future studies.
Collapse
Affiliation(s)
- Hannah L Klein
- New York University School of Medicine, Department of Biochemistry and Molecular Pharmacology, New York, NY 10016, USA
| | - Kenny K H Ang
- Small Molecule Discovery Center and Department of Pharmaceutical Chemistry, University of California, San Francisco, California 94143, USA
| | - Michelle R Arkin
- Small Molecule Discovery Center and Department of Pharmaceutical Chemistry, University of California, San Francisco, California 94143, USA
| | - Emily C Beckwitt
- Program in Molecular Biophysics and Structural Biology, University of Pittsburgh, Pittsburgh, PA 15261, USA.,The University of Pittsburgh Cancer Institute, Hillman Cancer Center, Pittsburgh, PA 15213, USA
| | - Yi-Hsuan Chang
- Institute of Biochemical Sciences, National Taiwan University, NO. 1, Section 4, Roosevelt Road, Taipei 10617, Taiwan
| | - Jun Fan
- Biological Physics Research Group, Clarendon Laboratory, Department of Physics, University of Oxford, Oxford, OX1 3PU, UK
| | - Youngho Kwon
- Department of Molecular Biophysics and Biochemistry, Yale University School of Medicine, New Haven, CT 06520, USA.,Department of Biochemistry and Structural Biology, University of Texas Health San Antonio, San Antonio, Texas 78229, USA
| | - Michael J Morten
- New York University School of Medicine, Department of Biochemistry and Molecular Pharmacology, New York, NY 10016, USA
| | - Sucheta Mukherjee
- Department of Microbiology and Molecular Genetics, University of California, Davis, CA 95616, USA
| | - Oliver J Pambos
- Biological Physics Research Group, Clarendon Laboratory, Department of Physics, University of Oxford, Oxford, OX1 3PU, UK
| | - Hafez El Sayyed
- Biological Physics Research Group, Clarendon Laboratory, Department of Physics, University of Oxford, Oxford, OX1 3PU, UK
| | - Elizabeth S Thrall
- Department of Biological Chemistry and Molecular Pharmacology, Harvard Medical School, 250 Longwood Avenue, Boston, MA 02115, USA
| | - João P Vieira-da-Rocha
- Department of Microbiology and Molecular Genetics, University of California, Davis, CA 95616, USA
| | - Quan Wang
- Department of Molecular and Cellular Biochemistry, Indiana University, Bloomington, IN 47405, USA
| | - Shuang Wang
- Ecole Normale Supérieure, Institut de Biologie de l'Ecole Normale Supérieure (IBENS), CNRS, INSERM, PSL Research University, 75005 Paris, France.,Institut Jacques Monod, CNRS, UMR7592, University Paris Diderot, Sorbonne Paris Cité F-75205 Paris, France
| | - Hsin-Yi Yeh
- Institute of Biochemical Sciences, National Taiwan University, NO. 1, Section 4, Roosevelt Road, Taipei 10617, Taiwan
| | - Julie S Biteen
- Departments of Chemistry and Biophysics, University of Michigan, Ann Arbor, MI 48109, USA
| | - Peter Chi
- Institute of Biochemical Sciences, National Taiwan University, NO. 1, Section 4, Roosevelt Road, Taipei 10617, Taiwan.,Institute of Biological Chemistry, Academia Sinica, 128 Academia Road, Section 2, Nankang, Taipei 11529, Taiwan
| | - Wolf-Dietrich Heyer
- Department of Microbiology and Molecular Genetics, University of California, Davis, CA 95616, USA.,Department of Molecular and Cellular Biology, University of California, Davis, CA 95616, USA
| | - Achillefs N Kapanidis
- Biological Physics Research Group, Clarendon Laboratory, Department of Physics, University of Oxford, Oxford, OX1 3PU, UK
| | - Joseph J Loparo
- Department of Biological Chemistry and Molecular Pharmacology, Harvard Medical School, 250 Longwood Avenue, Boston, MA 02115, USA
| | - Terence R Strick
- Ecole Normale Supérieure, Institut de Biologie de l'Ecole Normale Supérieure (IBENS), CNRS, INSERM, PSL Research University, 75005 Paris, France.,Institut Jacques Monod, CNRS, UMR7592, University Paris Diderot, Sorbonne Paris Cité F-75205 Paris, France.,Programme Equipe Labellisées, Ligue Contre le Cancer, 75013 Paris, France
| | - Patrick Sung
- Department of Molecular Biophysics and Biochemistry, Yale University School of Medicine, New Haven, CT 06520, USA.,Department of Biochemistry and Structural Biology, University of Texas Health San Antonio, San Antonio, Texas 78229, USA
| | - Bennett Van Houten
- Program in Molecular Biophysics and Structural Biology, University of Pittsburgh, Pittsburgh, PA 15261, USA.,Program in Molecular Biophysics and Structural Biology, University of Pittsburgh, Pittsburgh, PA 15261, USA.,Department of Pharmacology and Chemical Biology, University of Pittsburgh, Pittsburgh, PA 15261, USA
| | - Hengyao Niu
- Department of Molecular and Cellular Biochemistry, Indiana University, Bloomington, IN 47405, USA
| | - Eli Rothenberg
- New York University School of Medicine, Department of Biochemistry and Molecular Pharmacology, New York, NY 10016, USA
| |
Collapse
|
12
|
Börner R, Kowerko D, Hadzic MCAS, König SLB, Ritter M, Sigel RKO. Simulations of camera-based single-molecule fluorescence experiments. PLoS One 2018; 13:e0195277. [PMID: 29652886 PMCID: PMC5898730 DOI: 10.1371/journal.pone.0195277] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2017] [Accepted: 03/19/2018] [Indexed: 01/23/2023] Open
Abstract
Single-molecule microscopy has become a widely used technique in (bio)physics and (bio)chemistry. A popular implementation is single-molecule Förster Resonance Energy Transfer (smFRET), for which total internal reflection fluorescence microscopy is frequently combined with camera-based detection of surface-immobilized molecules. Camera-based smFRET experiments generate large and complex datasets and several methods for video processing and analysis have been reported. As these algorithms often address similar aspects in video analysis, there is a growing need for standardized comparison. Here, we present a Matlab-based software (MASH-FRET) that allows for the simulation of camera-based smFRET videos, yielding standardized data sets suitable for benchmarking video processing algorithms. The software permits to vary parameters that are relevant in cameras-based smFRET, such as video quality, and the properties of the system under study. Experimental noise is modeled taking into account photon statistics and camera noise. Finally, we survey how video test sets should be designed to evaluate currently available data analysis strategies in camera-based sm fluorescence experiments. We complement our study by pre-optimizing and evaluating spot detection algorithms using our simulated video test sets.
Collapse
Affiliation(s)
- Richard Börner
- Department of Chemistry, University of Zurich, Zurich, Switzerland
| | - Danny Kowerko
- Department of Computer Science, Chemnitz University of Technology, Chemnitz, Germany
| | | | - Sebastian L. B. König
- Department of Chemistry, University of Zurich, Zurich, Switzerland
- Department of Biochemistry, University of Zurich, Zurich, Switzerland
| | - Marc Ritter
- Department of Applied Computer and Biosciences, Mittweida University of Applied Sciences, Mittweida, Germany
| | | |
Collapse
|
13
|
Gyongy I, Davies A, Gallinet B, Dutton NAW, Duncan RR, Rickman C, Henderson RK, Dalgarno PA. Cylindrical microlensing for enhanced collection efficiency of small pixel SPAD arrays in single-molecule localisation microscopy. OPTICS EXPRESS 2018; 26:2280-2291. [PMID: 29401768 DOI: 10.1364/oe.26.002280] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Single-photon avalanche photodiode (SPAD) image sensors offer time-gated photon counting, at high binary frame rates of >100 kFPS and with no readout noise. This makes them well-suited to a range of scientific applications, including microscopy, sensing and quantum optics. However, due to the complex electronics required, the fill factor tends to be significantly lower (< 10%) than that of EMCCD and sCMOS cameras (>90%), whilst the pixel size is typically larger, impacting the sensitivity and practicalities of the SPAD devices. This paper presents the first characterisation of a cylindrical-shaped microlens array applied to a small, 8 micron, pixel SPAD imager. The enhanced fill factor, ≈50% for collimated light, is the highest reported value amongst SPAD sensors with comparable resolution and pixel pitch. We demonstrate the impact of the increased sensitivity in single-molecule localisation microscopy, obtaining a resolution of below 40nm, the best reported figure for a SPAD sensor.
Collapse
|
14
|
Voith von Voithenberg L, Lamb DC. Single Pair Förster Resonance Energy Transfer: A Versatile Tool To Investigate Protein Conformational Dynamics. Bioessays 2018; 40. [DOI: 10.1002/bies.201700078] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Revised: 12/05/2017] [Indexed: 01/23/2023]
Affiliation(s)
- Lena Voith von Voithenberg
- Department Chemie; Center for Nanoscience (CeNS); Center for Integrated Protein Science Munich (CIPSM); Nanosystem Initiative Munich (NIM); Ludwig-Maximilians-Universität München; Butenandtstr. 5-13 81377 München Germany
- BIOSS Centre for Signalling Studies; Schänzlestr. 18 79104 Freiburg Germany
| | - Don C. Lamb
- Department Chemie; Center for Nanoscience (CeNS); Center for Integrated Protein Science Munich (CIPSM); Nanosystem Initiative Munich (NIM); Ludwig-Maximilians-Universität München; Butenandtstr. 5-13 81377 München Germany
| |
Collapse
|
15
|
Badugu R, Jeng BH, Reece EA, Lakowicz JR. Contact lens to measure individual ion concentrations in tears and applications to dry eye disease. Anal Biochem 2017; 542:84-94. [PMID: 29183834 DOI: 10.1016/j.ab.2017.11.014] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Revised: 10/24/2017] [Accepted: 11/18/2017] [Indexed: 11/18/2022]
Abstract
Dry eye disease (DED) affects millions of individuals in the United States and worldwide, and the incidence is increasing with an aging population. There is widespread agreement that the measurement of total tear osmolarity is the most reliable test, but this procedure provides only the total ionic strength and does not provide the concentration of each ionic species in tears. Here, we describe an approach to determine the individual ion concentrations in tears using modern silicone hydrogel (SiHG) contact lenses. We made pH (or H3O+, hydronium cation,/OH-, hydroxyl ion) and chloride ion (two of the important electrolytes in tear fluid) sensitive SiHG contact lenses. We attached hydrophobic C18 chains to water-soluble fluorescent probes for pH and chloride. The resulting hydrophobic ion sensitive fluorophores (H-ISF) bind strongly to SiHG lenses and could not be washed out with aqueous solutions. Both H-ISFs provide measurements which are independent of total intensity by use of wavelength-ratiometric measurements for pH or lifetime-based sensing for chloride. Our approach can be extended to fabricate a contact lens which provides measurements of the six dominant ionic species in tears. This capability will be valuable for research into the biochemical processes causing DED, which may improve the ability to diagnose the various types of DED.
Collapse
Affiliation(s)
- Ramachandram Badugu
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 W. Lombard Street, Baltimore, MD 21201, USA.
| | - Bennie H Jeng
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, 419 W. Redwood Street, Suite 420, Baltimore, MD 21201, USA
| | - E Albert Reece
- Department of Obstetrics, Gynecology and Reproductive Sciences, University of Maryland School of Medicine, 655 W. Baltimore Street, Baltimore, MD 21201, USA; Department of Biochemistry & Molecular Biology, University of Maryland School of Medicine, 655 W. Baltimore Street, Baltimore, MD 21201, USA
| | - Joseph R Lakowicz
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 W. Lombard Street, Baltimore, MD 21201, USA
| |
Collapse
|
16
|
Wang Y, Zhao L, Hu Z, Wang Y, Zhao Z, Li L, Huang ZL. Quantitative performance evaluation of a back-illuminated sCMOS camera with 95% QE for super-resolution localization microscopy. Cytometry A 2017; 91:1175-1183. [PMID: 29165899 DOI: 10.1002/cyto.a.23282] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 09/29/2017] [Accepted: 10/18/2017] [Indexed: 11/07/2022]
Abstract
Scientific Complementary Metal Oxide Semiconductor (sCMOS) cameras were introduced into the market in 2009 and are now becoming a major type of commercial cameras for low-light imaging. sCMOS cameras provide simultaneously low read noise, high readout speed, and large pixel array; however, the relatively low quantum efficiency (QE) of sCMOS cameras has been a major limitation for its application in single molecule imaging, especially super-resolution localization microscopy which requires high detection sensitivity. Here we report the imaging performance of a newly released back-illuminated sCMOS camera (called Dhyana 95 from Tucsen) which is claimed to be the world's first 95% QE sCMOS camera. The imaging performance evaluation is based on a new methodology which is designed to provide paired images from two tested cameras under almost identical experimental conditions. We verified that this new 95% QE sCMOS camera is able to provide superior imaging performance over a representative front-illuminated sCMOS camera (Hamamatsu Flash 4.0 V2) and a popular back-illuminated EMCCD camera (Andor iXon 897 Ultra) in a wide signal range. We hope this study will inspire more studies on using sCMOS cameras in super-resolution localization microscopy, or even single molecule imaging. © 2017 International Society for Advancement of Cytometry.
Collapse
Affiliation(s)
- Yujie Wang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, 430074, China.,MoE Key Laboratory for Biomedical Photonics, Collaborative Innovation Center for Biomedical Engineering, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China
| | - Lingxi Zhao
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, 430074, China.,MoE Key Laboratory for Biomedical Photonics, Collaborative Innovation Center for Biomedical Engineering, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China
| | - Zhe Hu
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, 430074, China.,MoE Key Laboratory for Biomedical Photonics, Collaborative Innovation Center for Biomedical Engineering, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China
| | - Yina Wang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, 430074, China.,MoE Key Laboratory for Biomedical Photonics, Collaborative Innovation Center for Biomedical Engineering, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China
| | - Zeyu Zhao
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, 430074, China.,MoE Key Laboratory for Biomedical Photonics, Collaborative Innovation Center for Biomedical Engineering, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China
| | - Luchang Li
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, 430074, China.,MoE Key Laboratory for Biomedical Photonics, Collaborative Innovation Center for Biomedical Engineering, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China
| | - Zhen-Li Huang
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, 430074, China.,MoE Key Laboratory for Biomedical Photonics, Collaborative Innovation Center for Biomedical Engineering, School of Engineering Sciences, Huazhong University of Science and Technology, Wuhan, Hubei, 430074, China
| |
Collapse
|
17
|
Characterization of an industry-grade CMOS camera well suited for single molecule localization microscopy - high performance super-resolution at low cost. Sci Rep 2017; 7:14425. [PMID: 29089524 PMCID: PMC5663701 DOI: 10.1038/s41598-017-14762-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Accepted: 10/12/2017] [Indexed: 01/27/2023] Open
Abstract
Many commercial as well as custom-built fluorescence microscopes use scientific-grade cameras that represent a substantial share of the instrument's cost. This holds particularly true for super-resolution localization microscopy where high demands are placed especially on the detector with respect to sensitivity, noise, and also image acquisition speed. Here, we present and carefully characterize an industry-grade CMOS camera as a cost-efficient alternative to commonly used scientific cameras. Direct experimental comparison of these two detector types shows widely similar performance for imaging by single molecule localization microscopy (SMLM). Furthermore, high image acquisition speeds are demonstrated for the CMOS detector by ultra-fast SMLM imaging.
Collapse
|
18
|
Zhao Z, Xin B, Li L, Huang ZL. High-power homogeneous illumination for super-resolution localization microscopy with large field-of-view. OPTICS EXPRESS 2017; 25:13382-13395. [PMID: 28788875 DOI: 10.1364/oe.25.013382] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2017] [Accepted: 05/27/2017] [Indexed: 06/07/2023]
Abstract
As a wide-field imaging technique, super-resolution localization microscopy (SRLM) is theoretically capable of increasing field-of-view (FOV) without sacrificing either imaging speed or spatial resolution. There are two key factors for realizing large FOV SRLM: one is high-power illumination over the whole FOV with sufficient illumination homogeneity and the other is large FOV signal detection by a camera that has large number of pixels and sufficient detection sensitivity. However nowadays, even though the state-of-art scientific complementary metal-oxide semiconductor (sCMOS) cameras provide single molecule fluorescence signal detection ability over an FOV of more than 200 μm × 200 μm, large FOV SRLM still has not been achieved due to the lack of high-power homogeneous illumination. In this paper, we report large FOV SRLM with a high-power homogeneous illumination system. We demonstrate experimentally that our illumination system, which is based on a newly designed multimode fiber combiner, is capable of providing sufficient illumination intensity (~4.7 kW/cm2 @ 640 nm) and excellent illumination homogeneity. Compared with the reported approaches, our illumination system is advantageous in laser power scaling and square-shape illumination without beam clipping. As a result, our system makes full use of the sensor of a representative Hamamatsu Flash 4.0 V2 sCMOS camera (2048 × 2048 active pixels) and achieves a FOV as large as 221 μm × 221 μm with homogeneous spatial resolution. The flexible solution for realizing large FOV SRLM reported in this paper pushes a significant step toward the development of SRLM.
Collapse
|
19
|
Lin R, Clowsley AH, Jayasinghe ID, Baddeley D, Soeller C. Algorithmic corrections for localization microscopy with sCMOS cameras - characterisation of a computationally efficient localization approach. OPTICS EXPRESS 2017; 25:11701-11716. [PMID: 28788730 DOI: 10.1364/oe.25.011701] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Modern sCMOS cameras are attractive for single molecule localization microscopy (SMLM) due to their high speed but suffer from pixel non-uniformities that can affect localization precision and accuracy. We present a simplified sCMOS non-uniform noise model that incorporates pixel specific read-noise, offset and sensitivity variation. Using this model we develop a new weighted least squared (WLS) fitting method designed to remove the effect of sCMOS pixel non-uniformities. Simulations with the sCMOS noise model, performed to test under which conditions sCMOS specific localization corrections are required, suggested that pixel specific offsets should always be removed. In many applications with thick biological samples photon fluxes are sufficiently high that corrections of read-noise and sensitivity correction may be neglected. When correction is required, e.g. during fast imaging in thin samples, our WLS fit procedure recovered the performance of an equivalent sensor with uniform pixel properties and the fit estimates also attained the Cramer-Rao lower bound. Experiments with sub-resolution beads and a DNA origami test sample confirmed the results of the simulations. The WLS localization procedure is fast to converge, compatible with 2D, 3D and multi-emitter localization and thus provides a computationally efficient sCMOS localization approach compatible with most SMLM modalities.
Collapse
|
20
|
Juette MF, Terry DS, Wasserman MR, Altman RB, Zhou Z, Zhao H, Blanchard SC. Single-molecule imaging of non-equilibrium molecular ensembles on the millisecond timescale. Nat Methods 2016; 13:341-4. [PMID: 26878382 PMCID: PMC4814340 DOI: 10.1038/nmeth.3769] [Citation(s) in RCA: 175] [Impact Index Per Article: 21.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2015] [Accepted: 12/17/2015] [Indexed: 02/07/2023]
Abstract
Single-molecule fluorescence microscopy is uniquely suited for detecting transient molecular recognition events, yet achieving the time resolution and statistics needed to realize this potential has proven challenging. Here we present a single-molecule imaging and analysis platform using scientific complementary metal-oxide semiconductor (sCMOS) detectors that enables imaging of 15,000 individual molecules simultaneously at millisecond rates. This system enabled the detection of previously obscured processes relevant to the fidelity mechanism in protein synthesis.
Collapse
Affiliation(s)
- Manuel F. Juette
- Department of Physiology and Biophysics, Weill-Cornell Medical College, New York, NY, USA
| | - Daniel S. Terry
- Department of Physiology and Biophysics, Weill-Cornell Medical College, New York, NY, USA
| | - Michael R. Wasserman
- Department of Physiology and Biophysics, Weill-Cornell Medical College, New York, NY, USA
| | - Roger B. Altman
- Department of Physiology and Biophysics, Weill-Cornell Medical College, New York, NY, USA
| | - Zhou Zhou
- Department of Physiology and Biophysics, Weill-Cornell Medical College, New York, NY, USA
| | - Hong Zhao
- Department of Physiology and Biophysics, Weill-Cornell Medical College, New York, NY, USA
| | - Scott C. Blanchard
- Department of Physiology and Biophysics, Weill-Cornell Medical College, New York, NY, USA
| |
Collapse
|
21
|
Gust A, Zander A, Gietl A, Holzmeister P, Schulz S, Lalkens B, Tinnefeld P, Grohmann D. A starting point for fluorescence-based single-molecule measurements in biomolecular research. Molecules 2014; 19:15824-65. [PMID: 25271426 PMCID: PMC6271140 DOI: 10.3390/molecules191015824] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2014] [Revised: 09/17/2014] [Accepted: 09/17/2014] [Indexed: 01/24/2023] Open
Abstract
Single-molecule fluorescence techniques are ideally suited to provide information about the structure-function-dynamics relationship of a biomolecule as static and dynamic heterogeneity can be easily detected. However, what type of single-molecule fluorescence technique is suited for which kind of biological question and what are the obstacles on the way to a successful single-molecule microscopy experiment? In this review, we provide practical insights into fluorescence-based single-molecule experiments aiming for scientists who wish to take their experiments to the single-molecule level. We especially focus on fluorescence resonance energy transfer (FRET) experiments as these are a widely employed tool for the investigation of biomolecular mechanisms. We will guide the reader through the most critical steps that determine the success and quality of diffusion-based confocal and immobilization-based total internal reflection fluorescence microscopy. We discuss the specific chemical and photophysical requirements that make fluorescent dyes suitable for single-molecule fluorescence experiments. Most importantly, we review recently emerged photoprotection systems as well as passivation and immobilization strategies that enable the observation of fluorescently labeled molecules under biocompatible conditions. Moreover, we discuss how the optical single-molecule toolkit has been extended in recent years to capture the physiological complexity of a cell making it even more relevant for biological research.
Collapse
Affiliation(s)
- Alexander Gust
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany
| | - Adrian Zander
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany
| | - Andreas Gietl
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany
| | - Phil Holzmeister
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany
| | - Sarah Schulz
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany
| | - Birka Lalkens
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany
| | - Philip Tinnefeld
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany
| | - Dina Grohmann
- Physikalische und Theoretische Chemie - NanoBioSciences, Technische Universität Braunschweig, Hans-Sommer-Strasse 10, Braunschweig 38106, Germany.
| |
Collapse
|
22
|
Long F, Zeng SQ, Huang ZL. Effects of fixed pattern noise on single molecule localization microscopy. Phys Chem Chem Phys 2014; 16:21586-94. [PMID: 25189193 DOI: 10.1039/c4cp02280g] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The newly developed scientific complementary metal oxide semiconductor (sCMOS) cameras are capable of realizing fast single molecule localization microscopy without sacrificing field-of-view, benefiting from their readout speed which is significantly higher than that of conventional charge-coupled device (CCD) cameras. However, the poor image uniformity (suffered from fixed pattern noise, FPN) is a major obstruction for widespread use of sCMOS cameras in single molecule localization microscopy. Here we present a quantitative investigation on the effects of FPN on single molecule localization microscopy via localization precision and localization bias. We found that FPN leads to almost no effect on localization precision, but introduces a certain amount of localization bias. However, for a commercial Hamamatsu Flash 4.0 sCMOS camera, such localization bias is usually <2 nm and thus can be neglected for most localization microscopy experiments. This study addresses the FPN concern which worries researchers, and thus will promote the application of sCMOS cameras in single molecule localization microscopy.
Collapse
Affiliation(s)
- F Long
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan 430074, China.
| | | | | |
Collapse
|
23
|
Juette MF, Terry DS, Wasserman MR, Zhou Z, Altman RB, Zheng Q, Blanchard SC. The bright future of single-molecule fluorescence imaging. Curr Opin Chem Biol 2014; 20:103-11. [PMID: 24956235 DOI: 10.1016/j.cbpa.2014.05.010] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2014] [Accepted: 05/09/2014] [Indexed: 11/13/2022]
Abstract
Single-molecule Förster resonance energy transfer (smFRET) is an essential and maturing tool to probe biomolecular interactions and conformational dynamics in vitro and, increasingly, in living cells. Multi-color smFRET enables the correlation of multiple such events and the precise dissection of their order and timing. However, the requirements for good spectral separation, high time resolution, and extended observation times place extraordinary demands on the fluorescent labels used in such experiments. Together with advanced experimental designs and data analysis, the development of long-lasting, non-fluctuating fluorophores is therefore proving key to progress in the field. Recently developed strategies for obtaining ultra-stable organic fluorophores spanning the visible spectrum are underway that will enable multi-color smFRET studies to deliver on their promise of previously unachievable biological insights.
Collapse
Affiliation(s)
- Manuel F Juette
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States
| | - Daniel S Terry
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States
| | - Michael R Wasserman
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States
| | - Zhou Zhou
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States
| | - Roger B Altman
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States
| | - Qinsi Zheng
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States; Tri-Institutional Training Program in Chemical Biology, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States
| | - Scott C Blanchard
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States; Tri-Institutional Training Program in Chemical Biology, Weill Medical College of Cornell University, 1300 York Avenue, New York, NY 10065, United States.
| |
Collapse
|
24
|
Hughes CD, Simons M, Mackenzie CE, Van Houten B, Kad NM. Single molecule techniques in DNA repair: a primer. DNA Repair (Amst) 2014; 20:2-13. [PMID: 24819596 DOI: 10.1016/j.dnarep.2014.02.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Accepted: 02/03/2014] [Indexed: 10/25/2022]
Abstract
A powerful new approach has become much more widespread and offers insights into aspects of DNA repair unattainable with billions of molecules. Single molecule techniques can be used to image, manipulate or characterize the action of a single repair protein on a single strand of DNA. This allows search mechanisms to be probed, and the effects of force to be understood. These physical aspects can dominate a biochemical reaction, where at the ensemble level their nuances are obscured. In this paper we discuss some of the many technical advances that permit study at the single molecule level. We focus on DNA repair to which these techniques are actively being applied. DNA repair is also a process that encompasses so much of what single molecule studies benefit--searching for targets, complex formation, sequential biochemical reactions and substrate hand-off to name just a few. We discuss how single molecule biophysics is poised to transform our understanding of biological systems, in particular DNA repair.
Collapse
Affiliation(s)
- Craig D Hughes
- School of Biological Sciences, University of Essex, Wivenhoe Park, Colchester CO4 3SQ, UK
| | - Michelle Simons
- School of Biological Sciences, University of Essex, Wivenhoe Park, Colchester CO4 3SQ, UK
| | - Cassidy E Mackenzie
- School of Biological Sciences, University of Essex, Wivenhoe Park, Colchester CO4 3SQ, UK
| | - Bennett Van Houten
- Department of Pharmacology and Chemical Biology, University of Pittsburgh Cancer Institute, University of Pittsburgh, Pittsburgh, PA, USA
| | - Neil M Kad
- School of Biological Sciences, University of Essex, Wivenhoe Park, Colchester CO4 3SQ, UK.
| |
Collapse
|
25
|
Zheng Q, Juette MF, Jockusch S, Wasserman MR, Zhou Z, Altman RB, Blanchard SC. Ultra-stable organic fluorophores for single-molecule research. Chem Soc Rev 2014; 43:1044-56. [PMID: 24177677 PMCID: PMC3946787 DOI: 10.1039/c3cs60237k] [Citation(s) in RCA: 261] [Impact Index Per Article: 26.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Fluorescence provides a mechanism for achieving contrast in biological imaging that enables investigations of molecular structure, dynamics, and function at high spatial and temporal resolution. Small-molecule organic fluorophores have proven essential for such efforts and are widely used in advanced applications such as single-molecule and super-resolution microscopy. Yet, organic fluorophores, like all fluorescent species, exhibit instabilities in their emission characteristics, including blinking and photobleaching that limit their utility and performance. Here, we review the photophysics and photochemistry of organic fluorophores as they pertain to mitigating such instabilities, with a specific focus on the development of stabilized fluorophores through derivatization. Self-healing organic fluorophores, wherein the triplet state is intramolecularly quenched by a covalently attached protective agent, exhibit markedly improved photostabilities. We discuss the potential for further enhancements towards the goal of developing "ultra-stable" fluorophores spanning the visible spectrum and how such fluorophores are likely to impact the future of single-molecule research.
Collapse
Affiliation(s)
- Qinsi Zheng
- Department of Physiology and Biophysics, Weill Medical College of Cornell University, New York, USA.
| | | | | | | | | | | | | |
Collapse
|
26
|
Beier HT, Ibey BL. Experimental comparison of the high-speed imaging performance of an EM-CCD and sCMOS camera in a dynamic live-cell imaging test case. PLoS One 2014; 9:e84614. [PMID: 24404178 PMCID: PMC3880299 DOI: 10.1371/journal.pone.0084614] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Accepted: 11/15/2013] [Indexed: 12/19/2022] Open
Abstract
The study of living cells may require advanced imaging techniques to track weak and rapidly changing signals. Fundamental to this need is the recent advancement in camera technology. Two camera types, specifically sCMOS and EM-CCD, promise both high signal-to-noise and high speed (>100 fps), leaving researchers with a critical decision when determining the best technology for their application. In this article, we compare two cameras using a live-cell imaging test case in which small changes in cellular fluorescence must be rapidly detected with high spatial resolution. The EM-CCD maintained an advantage of being able to acquire discernible images with a lower number of photons due to its EM-enhancement. However, if high-resolution images at speeds approaching or exceeding 1000 fps are desired, the flexibility of the full-frame imaging capabilities of sCMOS is superior.
Collapse
Affiliation(s)
- Hope T. Beier
- 1th Human Performance Wing, Bioeffects Division, Air Force Research Laboratory, Fort Sam Houston, Texas, United States of America
- * E-mail:
| | - Bennett L. Ibey
- 1th Human Performance Wing, Bioeffects Division, Air Force Research Laboratory, Fort Sam Houston, Texas, United States of America
| |
Collapse
|
27
|
Abstract
Charge-coupled device and, increasingly, scientific complementary metal oxide semiconductor cameras are the most common digital detectors used for quantitative microscopy applications. Manufacturers provide technical specification data on the average or expected performance characteristics for each model of camera. However, the performance of individual cameras may vary, and many of the characteristics that are important for quantitation can be easily measured. Though it may seem obvious, it is important to remember that the digitized image you collect is merely a representation of the sample itself--and no camera can capture a perfect representation of an optical image. A clear understanding and characterization of the sources of noise and imprecision in your camera are important for rigorous quantitative analysis of digital images. In this chapter, we review the camera performance characteristics that are most critical for generating accurate and precise quantitative data and provide a step-by-step protocol for measuring these characteristics in your camera.
Collapse
|
28
|
Abstract
Superresolution localization microscopy methods produce nanoscale images via a combination of intermittently active fluorescent probes and algorithms that can precisely determine the positions of these probes from single-molecule or few-molecule images. These algorithms vary widely in their underlying principles, complexity, and accuracy. In this review, we begin by surveying the principles of localization microscopy and describing the fundamental limits to localization precision. We then examine several different families of fluorophore localization algorithms, comparing their complexity, performance, and range of applicability (e.g., whether they require particular types of experimental information, are optimized for specific situations, or are more general). Whereas our focus is on the localization of single isotropic emitters in two dimensions, we also consider oriented dipoles, three-dimensional localization, and algorithms that can handle overlapping images of several nearby fluorophores. Throughout the review, we try to highlight practical advice for users of fluorophore localization algorithms, as well as open questions.
Collapse
Affiliation(s)
- Alexander R Small
- Department of Physics and Astronomy, California State Polytechnic University, Pomona, California 91768
| | | |
Collapse
|
29
|
Jung J, Weisenburger S, Albert S, Gilbert DF, Friedrich O, Eulenburg V, Kornhuber J, Groemer TW. Performance of scientific cameras with different sensor types in measuring dynamic processes in fluorescence microscopy. Microsc Res Tech 2013; 76:835-43. [DOI: 10.1002/jemt.22236] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2012] [Revised: 03/19/2013] [Accepted: 04/26/2013] [Indexed: 11/09/2022]
Affiliation(s)
- Jasmin Jung
- Department of Psychiatry and Psychotherapy; Friedrich-Alexander-University of Erlangen-Nuremberg; Erlangen 91054 Germany
| | - Siegfried Weisenburger
- Nano-Optics Division, Max Planck Institute for the Science of Light; Erlangen 91058 Germany
| | - Sahradha Albert
- Department of Psychiatry and Psychotherapy; Friedrich-Alexander-University of Erlangen-Nuremberg; Erlangen 91054 Germany
| | - Daniel F. Gilbert
- Institute of Medical Biotechnology; Friedrich-Alexander-University of Erlangen-Nuremberg; Erlangen 91052 Germany
| | - Oliver Friedrich
- Institute of Medical Biotechnology; Friedrich-Alexander-University of Erlangen-Nuremberg; Erlangen 91052 Germany
| | - Volker Eulenburg
- Department of Biochemistry and Molecular Medicine; Friedrich-Alexander-University of Erlangen-Nuremberg; Erlangen 91054 Germany
| | - Johannes Kornhuber
- Department of Psychiatry and Psychotherapy; Friedrich-Alexander-University of Erlangen-Nuremberg; Erlangen 91054 Germany
| | - Teja W. Groemer
- Department of Psychiatry and Psychotherapy; Friedrich-Alexander-University of Erlangen-Nuremberg; Erlangen 91054 Germany
| |
Collapse
|
30
|
Video-rate nanoscopy using sCMOS camera-specific single-molecule localization algorithms. Nat Methods 2013; 10:653-8. [PMID: 23708387 PMCID: PMC3696415 DOI: 10.1038/nmeth.2488] [Citation(s) in RCA: 330] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2012] [Accepted: 04/22/2013] [Indexed: 12/12/2022]
Abstract
Newly developed scientific complementary metal–oxide–semiconductor (sCMOS) cameras have the potential to dramatically accelerate data acquisition in single-molecule switching nanoscopy (SMSN) while simultaneously increasing the effective quantum efficiency. However, sCMOS-intrinsic pixel-dependent readout noise substantially reduces the localization precision and introduces localization artifacts. Here we present algorithms that overcome these limitations and provide unbiased, precise localization of single molecules at the theoretical limit. In combination with a multi-emitter fitting algorithm, we demonstrate single-molecule localization super-resolution imaging at up to 32 reconstructed images/second (recorded at 1,600–3,200 camera frames/second) in both fixed and living cells.
Collapse
|
31
|
Bhaduri B, Wickland D, Wang R, Chan V, Bashir R, Popescu G. Cardiomyocyte imaging using real-time spatial light interference microscopy (SLIM). PLoS One 2013; 8:e56930. [PMID: 23457641 PMCID: PMC3574023 DOI: 10.1371/journal.pone.0056930] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2012] [Accepted: 01/16/2013] [Indexed: 02/02/2023] Open
Abstract
Spatial light interference microscopy (SLIM) is a highly sensitive quantitative phase imaging method, which is capable of unprecedented structure studies in biology and beyond. In addition to the π/2 shift introduced in phase contrast between the scattered and unscattered light from the sample, 4 phase shifts are generated in SLIM, by increments of π/2 using a reflective liquid crystal phase modulator (LCPM). As 4 phase shifted images are required to produce a quantitative phase image, the switching speed of the LCPM and the acquisition rate of the camera limit the acquisition rate and, thus, SLIM's applicability to highly dynamic samples. In this paper we present a fast SLIM setup which can image at a maximum rate of 50 frames per second and provide in real-time quantitative phase images at 50/4 = 12.5 frames per second. We use a fast LCPM for phase shifting and a fast scientific-grade complementary metal oxide semiconductor (sCMOS) camera (Andor) for imaging. We present the dispersion relation, i.e. decay rate vs. spatial mode, associated with dynamic beating cardiomyocyte cells from the quantitative phase images obtained with the real-time SLIM system.
Collapse
Affiliation(s)
- Basanta Bhaduri
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - David Wickland
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - Ru Wang
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - Vincent Chan
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - Rashid Bashir
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
| | - Gabriel Popescu
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, United States of America
- * E-mail:
| |
Collapse
|
32
|
Long F, Zeng S, Huang ZL. Localization-based super-resolution microscopy with an sCMOS camera part II: experimental methodology for comparing sCMOS with EMCCD cameras. OPTICS EXPRESS 2012; 20:17741-17759. [PMID: 23038326 DOI: 10.1364/oe.20.017741] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Nowadays, there is a hot debate among industry and academic researchers that whether the newly developed scientific-grade Complementary Metal Oxide Semiconductor (sCMOS) cameras could become the image sensors of choice in localization-based super-resolution microscopy. To help researchers find answers to this question, here we reported an experimental methodology for quantitatively comparing the performance of low-light cameras in single molecule detection (characterized via image SNR) and localization (via localization accuracy). We found that a newly launched sCMOS camera can present superior imaging performance than a popular Electron Multiplying Charge Coupled Device (EMCCD) camera in a signal range (15-12000 photon/pixel) more than enough for typical localization-based super-resolution microscopy.
Collapse
Affiliation(s)
- Fan Long
- Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan 430074, China
| | | | | |
Collapse
|