1
|
Wang C, Yin Z, He B, Chen Z, Hu Z, Shi Y, Zhang X, Zhang N, Jing L, Wang G, Xue P. Polarization-isolated stretched-pulse mode-locked swept laser for 10.3-MHz A-line rate optical coherence tomography. OPTICS LETTERS 2023; 48:4025-4028. [PMID: 37527109 DOI: 10.1364/ol.495786] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 07/10/2023] [Indexed: 08/03/2023]
Abstract
Stretched-pulse mode-locked (SPML) lasing based on a chirped fiber Bragg grating (CFBG) has proven to be a powerful method to generate wavelength-swept lasers at speeds of tens of megahertz. However, light transmitted through the CFBG may lead to undesirable laser oscillation that disrupts the mechanism of the laser active mode locking in the theta ring cavity. In this Letter, we demonstrate a simple and low-cost approach to suppress the transmitted light and achieve an effective duty cycle of ∼100% with only one CFBG and no need for intra-cavity semiconductor optical amplifier (SOA) modulation, extra-cavity optical buffering, and post amplification. By utilizing polarization isolation of the bi-directional CFBG, a swept laser centered at 1305 nm, with repetition rate of 10.3 MHz, optical power of 84 mW, and 3 dB bandwidth of 109 nm, is demonstrated. Ultrahigh speed 3D optical coherence tomography (OCT) structural imaging of a human palm in vivo using this swept laser is also demonstrated. We believe that this ultrahigh speed swept laser will greatly promote the OCT technique for industrial and biomedical applications.
Collapse
|
2
|
Lee B, Jeong S, Lee J, Kim TS, Braaf B, Vakoc BJ, Oh WY. Wide-Field Three-Dimensional Depth-Invariant Cellular-Resolution Imaging of the Human Retina. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2203357. [PMID: 36642824 PMCID: PMC10023497 DOI: 10.1002/smll.202203357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 12/02/2022] [Indexed: 06/17/2023]
Abstract
Three-dimensional (3D) cellular-resolution imaging of the living human retina over a large field of view will bring a great impact in clinical ophthalmology, potentially finding new biomarkers for early diagnosis and improving the pathophysiological understanding of ocular diseases. While hardware-based and computational adaptive optics (AO) optical coherence tomography (OCT) have been developed to achieve cellular-resolution retinal imaging, these approaches support limited 3D imaging fields, and their high cost and intrinsic hardware complexity limit their practical utility. Here, this work demonstrates 3D depth-invariant cellular-resolution imaging of the living human retina over a 3 × 3 mm field of view using the first intrinsically phase-stable multi-MHz retinal swept-source OCT and novel computational defocus and aberration correction methods. Single-acquisition imaging of photoreceptor cells, retinal nerve fiber layer, and retinal capillaries is presented across unprecedented imaging fields. By providing wide-field 3D cellular-resolution imaging in the human retina using a standard point-scan architecture routinely used in the clinic, this platform proposes a strategy for expanded utilization of high-resolution retinal imaging in both research and clinical settings.
Collapse
Affiliation(s)
- ByungKun Lee
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
- KI for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Sunhong Jeong
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
- KI for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Joosung Lee
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
- KI for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| | - Tae Shik Kim
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston 02140, USA
| | - Boy Braaf
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston 02140, USA
| | - Benjamin J. Vakoc
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston 02140, USA
| | - Wang-Yuhl Oh
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
- KI for Health Science and Technology, Korea Advanced Institute of Science and Technology, Daejeon 34141, Republic of Korea
| |
Collapse
|
3
|
Xu L, Zhang L, Wang K, Liu C, Zhang C, Zhang X. Dual-comb based time-stretch optical coherence tomography for large and segmental imaging depth. OPTICS EXPRESS 2022; 30:39014-39024. [PMID: 36258452 DOI: 10.1364/oe.469795] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Accepted: 09/29/2022] [Indexed: 06/16/2023]
Abstract
Optical coherence tomography based on time-stretch enables high frame rate and high-resolution imaging for the inertia-free wavelength-swept mechanism. The fundamental obstacle is still the acquisition bandwidth's restriction on imaging depth. By introducing dual-comb with slightly different repetition rates, the induced Vernier effect is found to be capable of relieving the problem. In our work, a dual-comb based time-stretch optical coherence tomography is proposed and experimentally demonstrated, achieving a 1.5-m imaging depth and 200-kHz A-scan rate. Moreover, about a 33.4-µm resolution and 25-µm accuracy are achieved. In addition, by adjusting the frequency detuning of the dual-comb, the A-scan rate can be further boosted to video-rate imaging. With enlarged imaging depth, this scheme is promising for a wide range of applications, including light detection and ranging.
Collapse
|
4
|
Lippok N, Vakoc BJ. RF properties of circular-ranging OCT signals. OPTICS LETTERS 2022; 47:1903-1906. [PMID: 35363765 PMCID: PMC9027934 DOI: 10.1364/ol.450318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Accepted: 03/03/2022] [Indexed: 06/14/2023]
Abstract
Circular-ranging optical coherence tomography (CR-OCT) systems that use a time-stepped frequency comb source generate interference fringe signals that are more complex than those of a conventional swept-source OCT system. Here, we define a common terminology for describing these signals, and we develop a mathematical framework that relates the radio-frequency (RF) properties of these fringe signals to the parameters of the frequency comb source. With this framework, we highlight non-intuitive mechanisms whereby the design of the frequency comb source can affect imaging performance. We show, for example, that amplitude-pulsed time-stepped frequency comb sources have a sensitivity advantage over constant power time-stepped frequency comb sources. More broadly, this framework and associated terminology provide a foundation on which to design and optimize time-stepped frequency comb sources and systems.
Collapse
Affiliation(s)
- Norman Lippok
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Benjamin J. Vakoc
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA
| |
Collapse
|
5
|
Joo J, Kim TS, Vakoc BJ, Oh WY. Robust and easy-to-operate stretched-pulse mode-locked wavelength-swept laser with an all-polarization-maintaining fiber cavity for 10 MHz A-line rate optical coherence tomography. OPTICS LETTERS 2021; 46:3857-3860. [PMID: 34388759 PMCID: PMC8455078 DOI: 10.1364/ol.424835] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 06/01/2021] [Indexed: 05/18/2023]
Abstract
We demonstrate robust and easy-to-operate stretched-pulse mode-locked laser (SPML) architectures using all-polarization-maintaining fiber laser cavities. Because of the polarization-maintaining construction, the laser performance is unaffected by mechanical perturbation on the cavity fibers. The lasers automatically initiate linear-in-wavenumber sweeps across 100 nm centered at 1290 nm with a 10 MHz repetition rate. OCT imaging with a sensitivity of 98 dB and a single-sided 6 dB coherence length of 2.5 mm is demonstrated. OCT angiography of a mouse brain that visualized three-dimensional cerebral microvasculature over a field of 1.5mm×1.5mm (398 A-lines × 380 B-scans) at a rate of 5.26 volumes per second is also presented. The robust all-PMF SPML lasers are a turnkey, high-performance source for ultrahigh-speed OCT imaging.
Collapse
Affiliation(s)
- JongYoon Joo
- Department of Mechanical Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KI for Health Science and Technology, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| | - Tae Shik Kim
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114, USA
| | - Benjamin J. Vakoc
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114, USA
| | - Wang-Yuhl Oh
- Department of Mechanical Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
- KI for Health Science and Technology, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea
| |
Collapse
|
6
|
Zhang J, Nguyen T, Potsaid B, Jayaraman V, Burgner C, Chen S, Li J, Liang K, Cable A, Traverso G, Mashimo H, Fujimoto JG. Multi-MHz MEMS-VCSEL swept-source optical coherence tomography for endoscopic structural and angiographic imaging with miniaturized brushless motor probes. BIOMEDICAL OPTICS EXPRESS 2021; 12:2384-2403. [PMID: 33996236 PMCID: PMC8086463 DOI: 10.1364/boe.420394] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 03/10/2021] [Accepted: 03/18/2021] [Indexed: 05/02/2023]
Abstract
Swept source optical coherence tomography (SS-OCT) enables volumetric imaging of subsurface structure. However, applications requiring wide fields of view (FOV), rapid imaging, and higher resolutions have been challenging because multi-MHz axial scan (A-scan) rates are needed. We describe a microelectromechanical systems vertical cavity surface-emitting laser (MEMS-VCSEL) SS-OCT technology for A-scan rates of 2.4 and 3.0 MHz. Sweep to sweep calibration and resampling are performed using dual channel acquisition of the OCT signal and a Mach Zehnder interferometer signal, overcoming inherent optical clock limitations and enabling higher performance. We demonstrate ultrahigh speed structural SS-OCT and OCT angiography (OCTA) imaging of the swine gastrointestinal tract using a suite of miniaturized brushless motor probes, including a 3.2 mm diameter micromotor OCT catheter, a 12 mm diameter tethered OCT capsule, and a 12 mm diameter widefield OCTA probe. MEMS-VCSELs promise to enable ultrahigh speed SS-OCT with a scalable, low cost, and manufacturable technology, suitable for a diverse range of imaging applications.
Collapse
Affiliation(s)
- Jason Zhang
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- These authors contributed equally to this work
| | - Tan Nguyen
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- These authors contributed equally to this work
| | - Benjamin Potsaid
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Advanced Imaging Group, Thorlabs Inc., Newton, NJ 07860, USA
| | | | | | - Siyu Chen
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Jinxi Li
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Kaicheng Liang
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Alex Cable
- Advanced Imaging Group, Thorlabs Inc., Newton, NJ 07860, USA
| | - Giovanni Traverso
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
- Division of Gastroenterology, Massachusetts General Hospital, Boston, MA 02114, USA
- Division of Gastroenterology, Brigham and Women’s Hospital, Boston, MA 02115, USA
- Harvard Medical School, Boston, MA 02115, USA
| | - Hiroshi Mashimo
- Harvard Medical School, Boston, MA 02115, USA
- Veterans Affairs Boston Healthcare System, Boston, MA 02132, USA
| | - James G. Fujimoto
- Department of Electrical Engineering and Computer Science, Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| |
Collapse
|
7
|
Pfeiffer T, Göb M, Draxinger W, Karpf S, Kolb JP, Huber R. Flexible A-scan rate MHz-OCT: efficient computational downscaling by coherent averaging. BIOMEDICAL OPTICS EXPRESS 2020; 11:6799-6811. [PMID: 33282524 PMCID: PMC7687947 DOI: 10.1364/boe.402477] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/18/2020] [Accepted: 09/28/2020] [Indexed: 05/29/2023]
Abstract
In order to realize adjustable A-scan rates of fast optical coherence tomography (OCT) systems, we investigate averaging of OCT image data acquired with a MHz-OCT system based on a Fourier Domain Mode Locked (FDML) laser. Increased system sensitivity and image quality can be achieved with the same system at the cost of lower imaging speed. Effectively, the A-scan rate can be reduced in software by a freely selectable factor. We demonstrate a detailed technical layout of the strategies necessary to achieve efficient coherent averaging. Since there are many new challenges specific to coherent averaging in swept source MHz-OCT, we analyze them point by point and describe the appropriate solutions. We prove that coherent averaging is possible at MHz OCT-speed without special interferometer designs or digital phase stabilization. We find, that in our system up to ∼100x coherent averaging is possible while achieving a sensitivity increase close to the ideal values. This corresponds to a speed reduction from 3.3 MHz to 33 kHz and a sensitivity gain of 20 dB. We show an imaging comparison between coherent and magnitude averaging of a human finger knuckle joint in vivo with 121 dB sensitivity for the coherent case. Further, the benefits of computational downscaling in low sensitivity MHz-OCT systems are analyzed.
Collapse
Affiliation(s)
- Tom Pfeiffer
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
- Optores GmbH, Gollierstr. 70, 80339 Munich, Germany
| | - Madita Göb
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| | - Wolfgang Draxinger
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| | - Sebastian Karpf
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| | - Jan Philip Kolb
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
- Medizinisches Laserzentrum Lübeck GmbH, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| | - Robert Huber
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| |
Collapse
|
8
|
Kim TS, Vakoc BJ. Stepped frequency comb generation based on electro-optic phase-code mode-locking for moderate-speed circular-ranging OCT. BIOMEDICAL OPTICS EXPRESS 2020; 11:3534-3542. [PMID: 33014549 PMCID: PMC7510900 DOI: 10.1364/boe.392359] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 05/07/2020] [Accepted: 05/08/2020] [Indexed: 06/11/2023]
Abstract
Circular-ranging (CR) optical coherence tomography (OCT) uses frequency comb sources to improve long-range imaging. While the initial development of CR-OCT focused on extremely high-speed imaging (i.e., operation at A-line rates of several to tens of MHz), there are many applications and imaging strategies for which more moderate speeds are preferred. However, we lack suitable frequency comb sources to enable moderate speed CR-OCT imaging. Here, we describe a novel phase-code mode-locking (PCML) laser architecture that can be operated from the kilohertz to megahertz range, while also offering novel features such as dynamic re-configurability and simplified linear-in-time frequency stepping. We demonstrate a prototype CR-OCT system with a PCML laser and present imaging results at A-line rates from 176 kHz to 3.52 MHz with coherence-length limited imaging depths as high as 170 mm.
Collapse
Affiliation(s)
- Tae Shik Kim
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Benjamin J. Vakoc
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| |
Collapse
|
9
|
Kim TS, Joo J, Shin I, Shin P, Kang WJ, Vakoc BJ, Oh WY. 9.4 MHz A-line rate optical coherence tomography at 1300 nm using a wavelength-swept laser based on stretched-pulse active mode-locking. Sci Rep 2020; 10:9328. [PMID: 32518256 PMCID: PMC7283258 DOI: 10.1038/s41598-020-66322-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Accepted: 05/08/2020] [Indexed: 01/07/2023] Open
Abstract
In optical coherence tomography (OCT), high-speed systems based at 1300 nm are among the most broadly used. Here, we present 9.4 MHz A-line rate OCT system at 1300 nm. A wavelength-swept laser based on stretched-pulse active mode locking (SPML) provides a continuous and linear-in-wavenumber sweep from 1240 nm to 1340 nm, and the OCT system using this light source provides a sensitivity of 98 dB and a single-sided 6-dB roll-off depth of 2.5 mm. We present new capabilities of the 9.4 MHz SPML-OCT system in three microscopy applications. First, we demonstrate high quality OCTA imaging at a rate of 1.3 volumes/s. Second, by utilizing its inherent phase stable characteristics, we present wide dynamic range en face Doppler OCT imaging with multiple time intervals ranging from 0.25 ms to 2.0 ms at a rate of 0.53 volumes/s. Third, we demonstrate video-rate 4D microscopic imaging of a beating Xenopus embryo heart at a rate of 30 volumes/s. This high-speed and high-performance OCT system centered at 1300 nm suggests that it can be one of the most promising high-speed OCT platforms enabling a wide range of new scientific research, industrial, and clinical applications at speeds of 10 MHz.
Collapse
Affiliation(s)
- Tae Shik Kim
- Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea.,KI for Health Science and Technology, KAIST, Daejeon, Republic of Korea
| | - JongYoon Joo
- Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea.,KI for Health Science and Technology, KAIST, Daejeon, Republic of Korea
| | - Inho Shin
- Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea.,KI for Health Science and Technology, KAIST, Daejeon, Republic of Korea
| | - Paul Shin
- Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea.,KI for Health Science and Technology, KAIST, Daejeon, Republic of Korea
| | - Woo Jae Kang
- Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea.,KI for Health Science and Technology, KAIST, Daejeon, Republic of Korea
| | - Benjamin J Vakoc
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA.
| | - Wang-Yuhl Oh
- Department of Mechanical Engineering, KAIST, Daejeon, Republic of Korea. .,KI for Health Science and Technology, KAIST, Daejeon, Republic of Korea.
| |
Collapse
|
10
|
Duan Y, Dong X, Zhang L, Li Y, Lei Z, Chen L, Zhou X, Zhang C, Zhang X. Ultrafast discrete swept source based on dual chirped combs for microscopic imaging. OPTICS EXPRESS 2019; 27:2621-2631. [PMID: 30732297 DOI: 10.1364/oe.27.002621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Accepted: 12/27/2018] [Indexed: 06/09/2023]
Abstract
An inertial-free, ultrafast frequency comb source based on two chirped optical frequency combs (OFCs) is proposed and experimentally demonstrated. The high linearity frequency sweeping is realized by the Vernier effect between the two OFCs rather than any mechanical motion component, so that good stability and reliability are ensured and no recalibration or resampling process is required. Swept rate up to 1 MHz is realized while keeping a narrow instantaneous linewidth of 0.03 nm, thanks to the extra-cavity frequency sweeping method. The wavelength step is proportional to the swept rate (3.8 pm at 10 kHz), and can be tuned by changing the repetition rate difference between the two OFCs. This swept source is applied for high-speed wavelength encoded imaging and achieves 4.4-μm spatial resolution at a 329-kHz frame rate. Compared with the traditional time-stretch microscopy, the signal acquisition bandwidth decreased from 3.8 GHz to below 90 MHz to achieve the same spatial resolution. Furthermore, the exposure time for a specific wavelength is much longer due to the discrete sweeping feature, which is a benefit for higher sensitivity. This discrete swept source provided a promising low-cost option for high-speed biomedical imaging systems and high-accuracy spectroscopy.
Collapse
|
11
|
Xu J, Li Y, Song S, Cepurna W, Morrison J, Wang RK. Evaluating changes of blood flow in retina, choroid, and outer choroid in rats in response to elevated intraocular pressure by 1300 nm swept-source OCT. Microvasc Res 2019; 121:37-45. [PMID: 30267716 PMCID: PMC6286199 DOI: 10.1016/j.mvr.2018.09.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2018] [Revised: 09/23/2018] [Accepted: 09/25/2018] [Indexed: 01/06/2023]
Abstract
We report the development of a 1300 nm swept-source optical coherence tomography (SS-OCT) system specifically designed to perform OCT imaging and optical microangiography (OMAG) in rat eyes in vivo and its use in evaluating the effects of intraocular pressure (IOP) elevation on ocular circulation. The swept laser is operated in single longitude mode with a 90 nm bandwidth centered at 1300 nm and 200 kHz A-line rate, providing remarkable sensitivity fall-off performance along the imaging depth, a larger field of view of 2.5 × 2.5 mm2 (approximately 35°), and more time-efficient imaging acquisition. The advantage of the SS-OCT/OMAG is highlighted by an increased imaging depth of the entire posterior thickness of optic nerve head (ONH) and its surrounding vascular anatomy, to include, for the first time in vivo, the vasculature at the scleral opening, allowing visualization of the circle of Zinn-Haller and posterior ciliary arteries (PCAs). Furthermore, the capillary-level resolution angiograms achieved at the retinal and choroidal layers over a larger field of view enable a significantly improved quantification of the response of vascular area density (VAD) to elevated IOP. The results indicate that reduction in perfusion of the choroid in response to elevated IOP is delayed compared to that seen in the retina; while choroidal VAD doesn't reach 50% of baseline until ~70 mmHg, the same effect is seen for the retinal VAD at ~60 mmHg. The superior image quality offered by SS-OCT may allow more comprehensive investigation of IOP-related ocular perfusion changes and their pathological roles in glaucomatous optic nerve damage.
Collapse
Affiliation(s)
- Jingjiang Xu
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
| | - Yuandong Li
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
| | - Shaozhen Song
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA
| | - William Cepurna
- Casey Eye Institute, Oregon Health & Science University, Portland, OR 97239, USA
| | - John Morrison
- Casey Eye Institute, Oregon Health & Science University, Portland, OR 97239, USA
| | - Ruikang K Wang
- University of Washington, Department of Bioengineering, Seattle, WA 98195, USA; University of Washington, Department of Ophthalmology, Seattle, WA 98104, USA.
| |
Collapse
|
12
|
Ko MO, Kim SJ, Kim JH, Jeon MY. In situobservation of dynamic pitch jumps of in-planar cholesteric liquid crystal layers based on wavelength-swept laser. OPTICS EXPRESS 2018; 26:28751-28762. [PMID: 30470047 DOI: 10.1364/oe.26.028751] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2018] [Accepted: 10/15/2018] [Indexed: 06/09/2023]
Abstract
We report in situ observation of dynamic pitch jumps in cholesteric liquid crystal (CLC) layers that depend on the applied electric field. A high-speed and wide bandwidth wavelength-swept laser is used as an optical broadband source to measure the dynamic pitch jumps. We could not observe the dynamic pitch jump in the quasi-static pitch variation. Instead, we carry out two driving methods, a normal driving and an overdriving method, in order to measure the dynamic pitch jump in the CLC cell. For the case of normal driving, it has been confirmed that the reflection band from the measurement region is discontinuously shifted by movement of the defect wall. The reflection band was compressed and recovered before the band moved, but the dynamic pitch jump of the helix could not be observed. For the case of overdriving, however, it was possible to observe the unwinding of the helix during the dynamic pitch jump. The entire dynamic pitch jump process in the CLC cell could be observed by measuring the transmission spectra from the CLC cell by varying the applied electric field. We confirm that the entire reaction time with the overdriving method was about 800 ms, which was shorter than with the normal driving method. This study contributes to the development of fast in-plane switching research and the development of new CLC devices.
Collapse
|
13
|
Tozburun S, Blatter C, Siddiqui M, Meijer EFJ, Vakoc BJ. Phase-stable Doppler OCT at 19 MHz using a stretched-pulse mode-locked laser. BIOMEDICAL OPTICS EXPRESS 2018; 9:952-961. [PMID: 29541496 PMCID: PMC5846541 DOI: 10.1364/boe.9.000952] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/18/2017] [Revised: 12/13/2017] [Accepted: 12/13/2017] [Indexed: 05/18/2023]
Abstract
We present a swept-wavelength optical coherence tomography (OCT) system with a 19 MHz laser source and electronic phase-locking of the source, acquisition clock, and beam scanning mirrors. The laser is based on stretched-pulse active mode-locking using an electro-optic modulator. Beam scanning in the fast axis uses a resonant micro-electromechanical systems (MEMS) -based mirror at ~23.8 kHz. Acquisition is performed at 1.78 Gigasamples per second using an external fixed clock. Phase sensitive imaging without need for k-clocking, A-line triggers, or phase-calibration methods is demonstrated. The system was used to demonstrate inter-frame and inter-volume Doppler imaging in the mouse ear and brain at 4D acquisition rates of 1, 30, 60 and 100 volumes/sec (V-scans/s). Angiography based on inter-frame and inter-volume methods are presented. The platform offers extremely fast and phase-stable measurements that can be used in preclinical angiographic and Doppler investigations of perfusion dynamics.
Collapse
Affiliation(s)
- Serhat Tozburun
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Izmir International Biomedicine and Genome Institute, Dokuz Eylul University, 35340 Balcova, Izmir, Turkey
| | - Cedric Blatter
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Meena Siddiqui
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139, USA
| | - Eelco F. J. Meijer
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Edwin L. Steele Laboratory for Tumor Biology, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Benjamin J. Vakoc
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139, USA
| |
Collapse
|
14
|
Siddiqui M, Nam AS, Tozburun S, Lippok N, Blatter C, Vakoc BJ. High-speed optical coherence tomography by circular interferometric ranging. NATURE PHOTONICS 2018; 12:111-116. [PMID: 29657576 PMCID: PMC5894866 DOI: 10.1038/s41566-017-0088-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Accepted: 12/18/2017] [Indexed: 05/17/2023]
Abstract
Existing three-dimensional optical imaging methods excel in controlled environments but are difficult to deploy over large, irregular and dynamic fields. This has limited imaging in areas such as material inspection and medicine. To better address these applications, we developed methods in optical coherence tomography (OCT) to efficiently interrogate sparse scattering fields, i.e., those in which most locations (voxels) do not generate meaningful signal. Frequency comb sources are used to superimpose reflected signals from equispaced locations through optical subsampling. This results in circular ranging, and reduces the number of measurements required to interrogate large volumetric fields. As a result, signal acquisition barriers that have limited speed and field in OCT are avoided. With a new ultrafast, time-stretched frequency comb laser design operating with 7.6 MHz to 18.9 MHz repetition rates, we achieved imaging of multi-cm3 fields at up to 7.5 volumes per second.
Collapse
Affiliation(s)
- Meena Siddiqui
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Harvard-MIT Health Sciences & Technology (HST), Cambridge, Massachusetts 02139, USA
| | - Ahhyun S. Nam
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Department of Mechanical Engineering, Massachusetts Institute of Technology (MIT), Cambridge, Massachusetts 02139, USA
| | - Serhat Tozburun
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Norman Lippok
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Cedric Blatter
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Benjamin J. Vakoc
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Harvard-MIT Health Sciences & Technology (HST), Cambridge, Massachusetts 02139, USA
- Correspondence to: Benjamin J. Vakoc
| |
Collapse
|
15
|
Xu J, Song S, Men S, Wang RK. Long ranging swept-source optical coherence tomography-based angiography outperforms its spectral-domain counterpart in imaging human skin microcirculations. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:1-11. [PMID: 29185292 PMCID: PMC5712670 DOI: 10.1117/1.jbo.22.11.116007] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Accepted: 11/08/2017] [Indexed: 05/07/2023]
Abstract
There is an increasing demand for imaging tools in clinical dermatology that can perform in vivo wide-field morphological and functional examination from surface to deep tissue regions at various skin sites of the human body. The conventional spectral-domain optical coherence tomography-based angiography (SD-OCTA) system is difficult to meet these requirements due to its fundamental limitations of the sensitivity roll-off, imaging range as well as imaging speed. To mitigate these issues, we demonstrate a swept-source OCTA (SS-OCTA) system by employing a swept source based on a vertical cavity surface-emitting laser. A series of comparisons between SS-OCTA and SD-OCTA are conducted. Benefiting from the high system sensitivity, long imaging range, and superior roll-off performance, the SS-OCTA system is demonstrated with better performance in imaging human skin than the SD-OCTA system. We show that the SS-OCTA permits remarkable deep visualization of both structure and vasculature (up to ∼2 mm penetration) with wide field of view capability (up to 18×18 mm2), enabling a more comprehensive assessment of the morphological features as well as functional blood vessel networks from the superficial epidermal to deep dermal layers. It is expected that the advantages of the SS-OCTA system will provide a ground for clinical translation, benefiting the existing dermatological practice.
Collapse
Affiliation(s)
- Jingjiang Xu
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | - Shaozhen Song
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | - Shaojie Men
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | | |
Collapse
|
16
|
Khazaeinezhad R, Siddiqui M, Vakoc BJ. 16 MHz wavelength-swept and wavelength-stepped laser architectures based on stretched-pulse active mode locking with a single continuously chirped fiber Bragg grating. OPTICS LETTERS 2017; 42:2046-2049. [PMID: 28504745 PMCID: PMC5521824 DOI: 10.1364/ol.42.002046] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
We demonstrate a novel high-speed and broadband laser architecture based on stretched pulse active mode locking that provides a wavelength-swept and wavelength-stepped output. The laser utilizes a single intracavity 8.3 meter chirped fiber Bragg grating to generate positive and negative dispersion, and can be operated with or without an intracavity fixed Fabry-Perot etalon to generate wavelength-swept and wavelength-stepped (frequency comb) outputs, respectively. Using a four-path delay line at the output, we achieved 16.3 MHz repetition rates and a 62 nm lasing bandwidth centered at 1550 nm. Single-sided double-pass coherence lengths of 1.25 mm for the wavelength-swept configuration and more than 30 mm for the wavelength-stepped configuration were obtained. Relative intensity noise was measured to be better than -140 dB/Hz. The stretched-pulse mode-locked architecture utilizing long chirped fiber Bragg gratings offers a simple and compact design for a broadband wavelength-tuned output at unprecedented speeds, and can address the need for fast sources in applications such as optical ranging, imaging, and sensing.
Collapse
Affiliation(s)
- Reza Khazaeinezhad
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Meena Siddiqui
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | - Benjamin J. Vakoc
- Harvard Medical School, Boston, Massachusetts 02115, USA
- Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, Massachusetts 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139, USA
| |
Collapse
|
17
|
Acousto-Optic-Based Wavelength-Comb-Swept Laser for Extended Displacement Measurements. SENSORS 2017; 17:s17040740. [PMID: 28362318 PMCID: PMC5421700 DOI: 10.3390/s17040740] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Revised: 03/27/2017] [Accepted: 03/28/2017] [Indexed: 11/17/2022]
Abstract
We demonstrate a novel wavelength-comb-swept laser based on two intra-cavity filters: an acousto-optic tunable filter (AOTF) and a Fabry-Pérot etalon filter. The AOTF is used for the tunable selection of the output wavelength with time and the etalon filter for the narrowing of the spectral linewidth to extend the coherence length. Compared to the conventional wavelength-swept laser, the acousto-optic–based wavelength-comb-swept laser (WCSL) can extend the measureable range of displacement measurements by decreasing the sensitivity roll-off of the point spread function. Because the AOTF contains no mechanical moving parts to select the output wavelength acousto-optically, the WCSL source has a high wavenumber (k) linearity of R2 = 0.9999 to ensure equally spaced wavelength combs in the wavenumber domain.
Collapse
|
18
|
Klein T, Huber R. High-speed OCT light sources and systems [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:828-859. [PMID: 28270988 PMCID: PMC5330584 DOI: 10.1364/boe.8.000828] [Citation(s) in RCA: 110] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 01/02/2017] [Accepted: 01/03/2017] [Indexed: 05/18/2023]
Abstract
Imaging speed is one of the most important parameters that define the performance of optical coherence tomography (OCT) systems. During the last two decades, OCT speed has increased by over three orders of magnitude. New developments in wavelength-swept lasers have repeatedly been crucial for this development. In this review, we discuss the historical evolution and current state of the art of high-speed OCT systems, with focus on wavelength swept light sources and swept source OCT systems.
Collapse
Affiliation(s)
- Thomas Klein
- Optores GmbH, Gollierstr. 70, 80339 Munich, Germany
| | - Robert Huber
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| |
Collapse
|
19
|
Wan M, Wang L, Li F, Cao Y, Wang X, Feng X, Guan BO, Wai PKA. Rapid, k-space linear wavelength scanning laser source based on recirculating frequency shifter. OPTICS EXPRESS 2016; 24:27614-27621. [PMID: 27906332 DOI: 10.1364/oe.24.027614] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
We propose and successfully demonstrate a k-space linear and self-clocked wavelength scanning fiber laser source based on recirculating frequency shifting (RFS). The RFS is realized with a high speed electro-optic dual parallel Mach-Zehnder modulator operating at the state of carrier suppressed single sideband modulation. A gated short pulse is injected into an amplified RFS loop to generate the wavelength scanning pulse train. We find that the accumulation of in-band amplified spontaneous emission (ASE) noise over multiple scanning periods will saturate the erbium-doped fiber amplifier and impede the amplification to the pulse signal in the RFS loop. To overcome the degradation of temporal signal due to the accumulation of ASE noise over multiple scanning periods, we insert a modulated optical switch into the RFS loop to completely attenuate the in-band ASE noise at the end of each scanning period. The signal to noise ratio of the temporal pulsed signal is greatly enhanced. K-space linear and self-clocked wavelength scanning fiber laser sources in 6.1 nm/7.2 nm scanning range with 20 GHz/30 GHz frequency shifting are successfully demonstrated.
Collapse
|
20
|
Malacarne A, Park Y, Li M, LaRochelle S, Azaña J. Real-time Fourier transformation of lightwave spectra and application in optical reflectometry. OPTICS EXPRESS 2015; 23:32516-32527. [PMID: 26699041 DOI: 10.1364/oe.23.032516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We propose and experimentally demonstrate a fiber-optics scheme for real-time analog Fourier transform (FT) of a lightwave energy spectrum, such that the output signal maps the FT of the spectrum of interest along the time axis. This scheme avoids the need for analog-to-digital conversion and subsequent digital signal post-processing of the photo-detected spectrum, thus being capable of providing the desired FT processing directly in the optical domain at megahertz update rates. The proposed concept is particularly attractive for applications requiring FT analysis of optical spectra, such as in many optical Fourier-domain reflectrometry (OFDR), interferometry, spectroscopy and sensing systems. Examples are reported to illustrate the use of the method for real-time OFDR, where the target axial-line profile is directly observed in a single-shot oscilloscope trace, similarly to a time-of-flight measurement, but with a resolution and depth of range dictated by the underlying interferometry scheme.
Collapse
|
21
|
Siddiqui M, Tozburun S, Zhang EZ, Vakoc BJ. Compensation of spectral and RF errors in swept-source OCT for high extinction complex demodulation. OPTICS EXPRESS 2015; 23:5508-20. [PMID: 25836784 PMCID: PMC4394752 DOI: 10.1364/oe.23.005508] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2014] [Revised: 01/16/2015] [Accepted: 01/17/2015] [Indexed: 05/19/2023]
Abstract
We provide a framework for compensating errors within passive optical quadrature demodulation circuits used in swept-source optical coherence tomography (OCT). Quadrature demodulation allows for detection of both the real and imaginary components of an interference fringe, and this information separates signals from positive and negative depth spaces. To achieve a high extinction (∼60 dB) between these positive and negative signals, the demodulation error must be less than 0.1% in amplitude and phase. It is difficult to construct a system that achieves this low error across the wide spectral and RF bandwidths of high-speed swept-source systems. In a prior work, post-processing methods for removing residual spectral errors were described. Here, we identify the importance of a second class of errors originating in the RF domain, and present a comprehensive framework for compensating both spectral and RF errors. Using this framework, extinctions >60 dB are demonstrated. A stability analysis shows that calibration parameters associated with RF errors are accurate for many days, while those associated with spectral errors must be updated prior to each imaging session. Empirical procedures to derive both RF and spectral calibration parameters simultaneously and to update spectral calibration parameters are presented. These algorithms provide the basis for using passive optical quadrature demodulation circuits with high speed and wide-bandwidth swept-source OCT systems.
Collapse
Affiliation(s)
- Meena Siddiqui
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139,
USA
- Wellman Center for Photomedicine, MGH, Boston, Massachusetts 02114,
USA
- Harvard Medical School, Boston, Massachusetts 02115,
USA
| | - Serhat Tozburun
- Wellman Center for Photomedicine, MGH, Boston, Massachusetts 02114,
USA
- Harvard Medical School, Boston, Massachusetts 02115,
USA
| | - Ellen Ziyi Zhang
- Wellman Center for Photomedicine, MGH, Boston, Massachusetts 02114,
USA
- Harvard Medical School, Boston, Massachusetts 02115,
USA
| | - Benjamin J. Vakoc
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, Massachusetts 02139,
USA
- Wellman Center for Photomedicine, MGH, Boston, Massachusetts 02114,
USA
- Harvard Medical School, Boston, Massachusetts 02115,
USA
| |
Collapse
|
22
|
Xu J, Wei X, Yu L, Zhang C, Xu J, Wong KKY, Tsia KK. Performance of megahertz amplified optical time-stretch optical coherence tomography (AOT-OCT). OPTICS EXPRESS 2014; 22:22498-512. [PMID: 25321720 DOI: 10.1364/oe.22.022498] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Enabled by the ultrahigh-speed all-optical wavelength-swept mechanism and broadband optical amplification, amplified optical time-stretch optical coherence tomography (AOT-OCT) has recently been demonstrated as a practical alternative to achieve ultrafast A-scan rate of multi-MHz in OCT. With the aim of identifying the optimal scenarios for MHz operation in AOT-OCT, we here present a theoretical framework to evaluate its performance metric. In particular, the analysis discusses the unique features of AOT-OCT, such as its superior coherence length, and the relationship between the optical gain and the A-scan rate. More importantly, we evaluate the sensitivity of AOT-OCT in the MHz regime under the influence of the amplifier noise. Notably, the model shows that AOT-OCT is particularly promising when operated at the A-scan rate well beyond multi-MHz--not trivially achievable by any existing swept-source OCT platform. A sensitivity beyond 90 dB, close to the shot-noise limit, can be maintained in the range of 2 - 10 MHz with an optical net gain of ~10 dB. Experimental measurement also shows excellent agreement with the theoretical prediction. While distributed fiber Raman amplification is mainly considered in this paper, the theoretical model is generally applicable to any type of amplification schemes. As a result, our analysis serves as a useful tool for further optimization of AOT-OCT system--as a practical alternative to enable MHz OCT operation.
Collapse
|