1
|
Tang JC, Magalhães R, Wisniowiecki A, Razura D, Walker C, Applegate BE. Optical coherence tomography technology in clinical applications. BIOPHOTONICS AND BIOSENSING 2024:285-346. [DOI: 10.1016/b978-0-44-318840-4.00017-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
|
2
|
Wisniowiecki AM, Applegate BE. Electronic frequency shifting enables long, variable working distance optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2023; 14:6579-6591. [PMID: 38420318 PMCID: PMC10898551 DOI: 10.1364/boe.504034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 11/15/2023] [Accepted: 11/16/2023] [Indexed: 03/02/2024]
Abstract
Increased imaging range is of growing interest in many applications of optical coherence tomography to reduce constraints on sample location, size, and topography. The design of optical coherence tomography systems with sufficient imaging range (e.g., 10s of centimeters) is a significant challenge due to the direct link between imaging range and acquisition bandwidth. We have developed a novel and flexible method to extend the imaging range in optical coherence tomography using electronic frequency shifting, enabling imaging in dynamic environments. In our approach, a laser with a quasi-linear sweep is used to limit the interferometric bandwidth, enabling decoupling of imaging range and acquisition bandwidth, while a tunable lens allows dynamic refocusing in the sample arm. Electronic frequency shifting then removes the need for high frequency digitization. This strategy is demonstrated to achieve high contrast morphological imaging over a > 21 cm working distance range, while maintaining high resolution and phase sensitivity. The system design is flexible to the application while requiring only a simple phase correction in post-processing. By implementing this approach in an auto-focusing paradigm, the proposed method demonstrates strong potential for the translation of optical coherence tomography into emerging applications requiring variable and centimeter-scale imaging ranges.
Collapse
Affiliation(s)
- Anna M. Wisniowiecki
- Department of Biomedical Engineering, Texas A&M University, 101 Bizzell St, College Station, TX 77843, USA
- Caruso Department of Otolaryngology–Head & Neck Surgery, University of Southern California, 1450 San Pablo St, Los Angeles, CA 90033, USA
| | - Brian E. Applegate
- Caruso Department of Otolaryngology–Head & Neck Surgery, University of Southern California, 1450 San Pablo St, Los Angeles, CA 90033, USA
- Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Los Angeles, CA 90089, USA
| |
Collapse
|
3
|
Quiñones PM, Meenderink SWF, Applegate BE, Oghalai JS. Unloading outer hair cell bundles in vivo does not yield evidence of spontaneous oscillations in the mouse cochlea. Hear Res 2022; 423:108473. [PMID: 35287989 PMCID: PMC9339463 DOI: 10.1016/j.heares.2022.108473] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 02/11/2022] [Accepted: 02/28/2022] [Indexed: 12/21/2022]
Abstract
Along with outer hair cell (OHC) somatic electromotility as the actuator of cochlear amplification, active hair bundle motility may be a complementary mechanism in the mammalian auditory system. Here, we searched the mouse cochlea for the presence of spontaneous bundle oscillations that have been observed in non-mammalian ears. In those systems, removal of the overlying membrane is necessary for spontaneous bundle oscillations to manifest. Thus, we used a genetic mouse model with a C1509G (cysteine-to-glycine) point mutation in the Tecta gene where the tectorial (TM) is lifted away from the OHC bundles, allowing us to explore whether unloaded bundles spontaneously oscillate. We used VOCTV in vivo to detect OHC length changes due to electromotility as a proxy for the spontaneous opening and closing of the mechanoelectrical transduction (MET) channels associated with bundle oscillation. In wild type mice with the TM attached to OHC bundles, we did find peaks in vibratory magnitude spectra. Such peaks were not observed in the mutants where the TM is detached from the OHC bundles. Statistical analysis of the time signals indicates that these peaks do not signify active oscillations. Rather, they are filtered responses of the sensitive wild type cochlea to weak background noise. We therefore conclude that, to the limits of our system (∼30 pm), there is no spontaneous mechanical activity that manifests as oscillations in OHC electromotility within the mouse cochlea, arguing that unloaded OHC bundles do not oscillate in vivo. This article is part of the Special Issue Outer hair cell Edited by Joseph Santos-Sacchi and Kumar Navaratnam.
Collapse
Affiliation(s)
- Patricia M Quiñones
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA, USA
| | | | - Brian E Applegate
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA, USA; Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA
| | - John S Oghalai
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA, USA.
| |
Collapse
|
4
|
Nankali A, Shera CA, Applegate BE, Oghalai JS. Interplay between traveling wave propagation and amplification at the apex of the mouse cochlea. Biophys J 2022; 121:2940-2951. [PMID: 35778839 PMCID: PMC9388393 DOI: 10.1016/j.bpj.2022.06.029] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 03/08/2022] [Accepted: 06/27/2022] [Indexed: 11/18/2022] Open
Abstract
Sounds entering the mammalian ear produce waves that travel from the base to the apex of the cochlea. An electromechanical active process amplifies traveling wave motions and enables sound processing over a broad range of frequencies and intensities. The cochlear amplifier requires combining the global traveling wave with the local cellular processes that change along the length of the cochlea given the gradual changes in hair cell and supporting cell anatomy and physiology. Thus, we measured basilar membrane (BM) traveling waves in vivo along the apical turn of the mouse cochlea using volumetric optical coherence tomography and vibrometry. We found that there was a gradual reduction in key features of the active process toward the apex. For example, the gain decreased from 23 to 19 dB and tuning sharpness decreased from 2.5 to 1.4. Furthermore, we measured the frequency and intensity dependence of traveling wave properties. The phase velocity was larger than the group velocity, and both quantities gradually decrease from the base to the apex denoting a strong dispersion characteristic near the helicotrema. Moreover, we found that the spatial wavelength along the BM was highly level dependent in vivo, such that increasing the sound intensity from 30 to 90 dB sound pressure level increased the wavelength from 504 to 874 μm, a factor of 1.73. We hypothesize that this wavelength variation with sound intensity gives rise to an increase of the fluid-loaded mass on the BM and tunes its local resonance frequency. Together, these data demonstrate a strong interplay between the traveling wave propagation and amplification along the length of the cochlea.
Collapse
Affiliation(s)
- Amir Nankali
- Caruso Department of Otolaryngology-Head and Neck Surgery, University of Southern California, Los Angeles, California
| | - Christopher A Shera
- Caruso Department of Otolaryngology-Head and Neck Surgery, University of Southern California, Los Angeles, California; Department of Physics and Astronomy, University of Southern California, Los Angeles, California
| | - Brian E Applegate
- Caruso Department of Otolaryngology-Head and Neck Surgery, University of Southern California, Los Angeles, California
| | - John S Oghalai
- Caruso Department of Otolaryngology-Head and Neck Surgery, University of Southern California, Los Angeles, California.
| |
Collapse
|
5
|
Kim W, Liu D, Kim S, Ratnayake K, Macias-Escriva F, Mattison S, Oghalai JS, Applegate BE. Vector of motion measurements in the living cochlea using a 3D OCT vibrometry system. BIOMEDICAL OPTICS EXPRESS 2022; 13:2542-2553. [PMID: 35519276 PMCID: PMC9045890 DOI: 10.1364/boe.451537] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 03/11/2022] [Accepted: 03/11/2022] [Indexed: 05/22/2023]
Abstract
Optical coherence tomography (OCT) has become an important tool for measuring the vibratory response of the living cochlea. It stands alone in its capacity to measure the intricate motion of the hearing organ through the surrounding otic capsule bone. Nevertheless, as an extension of phase-sensitive OCT, it is only capable of measuring motion along the optical axis. Hence, measurements are 1-D. To overcome this limitation and provide a measure of the 3-D vector of motion in the cochlea, we developed an OCT system with three sample arms in a single interferometer. Taking advantage of the long coherence length of our swept laser, we depth (frequency) encode the three channels. An algorithm to depth decode and coregister the three channels is followed by a coordinate transformation that takes the vibrational data from the experimental coordinate system to Cartesian or spherical polar coordinates. The system was validated using a piezo as a known vibrating element that could be positioned at various angles. The angular measurement on the piezo was shown to have an RMSE of ≤ 0.30° (5.2 mrad) with a standard deviation of the amplitude of ≤ 120 pm. Finally, we demonstrate the system for in vivo imaging by measuring the vector of motion over a volume image in the apex of the mouse cochlea.
Collapse
Affiliation(s)
- Wihan Kim
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA 90033, USA
- Contributed equally
| | - Derek Liu
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA 90033, USA
- Contributed equally
| | - Sangmin Kim
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Kumara Ratnayake
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA 90033, USA
| | - Frank Macias-Escriva
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA 90033, USA
| | - Scott Mattison
- Department of Biomedical Engineering, Texas A&M University, College Station, TX 77843, USA
- Current address: Department of Engineering and Physics, University of Central Oklahoma, Edmond, OK 73034, USA
| | - John S. Oghalai
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA 90033, USA
| | - Brian E. Applegate
- Caruso Department of Otolaryngology - Head and Neck Surgery, University of Southern California, Los Angeles, CA 90033, USA
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA. 90089, USA
| |
Collapse
|
6
|
Tomczewski S, Węgrzyn P, Borycki D, Auksorius E, Wojtkowski M, Curatolo A. Light-adapted flicker optoretinograms captured with a spatio-temporal optical coherence-tomography (STOC-T) system. BIOMEDICAL OPTICS EXPRESS 2022; 13:2186-2201. [PMID: 35519256 PMCID: PMC9045926 DOI: 10.1364/boe.444567] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/12/2021] [Revised: 02/20/2022] [Accepted: 02/23/2022] [Indexed: 06/14/2023]
Abstract
For many years electroretinography (ERG) has been used for obtaining information about the retinal physiological function. More recently, a new technique called optoretinography (ORG) has been developed. In one form of this technique, the physiological response of retinal photoreceptors to visible light, resulting in a nanometric photoreceptor optical path length change, is measured by phase-sensitive optical coherence tomography (OCT). To date, a limited number of studies with phase-based ORG measured the retinal response to a flickering light stimulation. In this work, we use a spatio-temporal optical coherence tomography (STOC-T) system to capture optoretinograms with a flickering stimulus over a 1.7 × 0.85 mm2 area of a light-adapted retina located between the fovea and the optic nerve. We show that we can detect statistically-significant differences in the photoreceptor optical path length (OPL) modulation amplitudes in response to different flicker frequencies and with better signal to noise ratios (SNRs) than for a dark-adapted eye. We also demonstrate the ability to spatially map such response to a patterned stimulus with light stripes flickering at different frequencies, highlighting the prospect of characterizing the spatially-resolved temporal-frequency response of the retina with ORG.
Collapse
Affiliation(s)
- Sławomir Tomczewski
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
- Equal contributors
| | - Piotr Węgrzyn
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
- Faculty of Physics, University of Warsaw, Pasteura 5, 02-093 Warszawa, Poland
- Equal contributors
| | - Dawid Borycki
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
| | - Egidijus Auksorius
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
- Center for Physical Sciences and Technology (FTMC), Saulėtekio al. 3, LT-10257 Vilnius, Lithuania
| | - Maciej Wojtkowski
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
| | - Andrea Curatolo
- International Centre for Translational Eye Research, Skierniewicka 10A, 01-230, Warszawa, Poland
- Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warszawa, Poland
| |
Collapse
|
7
|
Lui CG, Kim W, Dewey JB, Macías-Escrivá FD, Ratnayake K, Oghalai JS, Applegate BE. In vivo functional imaging of the human middle ear with a hand-held optical coherence tomography device. BIOMEDICAL OPTICS EXPRESS 2021; 12:5196-5213. [PMID: 34513251 PMCID: PMC8407818 DOI: 10.1364/boe.430935] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Revised: 07/02/2021] [Accepted: 07/06/2021] [Indexed: 06/13/2023]
Abstract
We describe an optical coherence tomography and vibrometry system designed for portable hand-held usage in the otology clinic on awake patients. The system provides clinically relevant point-of-care morphological imaging with 14-44 µm resolution and functional vibratory measures with sub-nanometer sensitivity. We evaluated various new approaches for extracting functional information including a multi-tone stimulus, a continuous chirp stimulus, and alternating air and bone stimulus. We also explored the vibratory response over an area of the tympanic membrane (TM) and generated TM thickness maps. Our results suggest that the system can provide real-time in vivo imaging and vibrometry of the ear and could prove useful for investigating otologic pathology in the clinic setting.
Collapse
Affiliation(s)
- Christopher G. Lui
- Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, 1450 San Pablo Street, Suite 5708, Los Angeles, CA 90033, USA
- These authors contributed equally to this work
| | - Wihan Kim
- Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, 1450 San Pablo Street, Suite 5708, Los Angeles, CA 90033, USA
- These authors contributed equally to this work
| | - James B. Dewey
- Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, 1450 San Pablo Street, Suite 5708, Los Angeles, CA 90033, USA
| | - Frank D. Macías-Escrivá
- Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, 1450 San Pablo Street, Suite 5708, Los Angeles, CA 90033, USA
| | - Kumara Ratnayake
- Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, 1450 San Pablo Street, Suite 5708, Los Angeles, CA 90033, USA
| | - John S. Oghalai
- Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, 1450 San Pablo Street, Suite 5708, Los Angeles, CA 90033, USA
| | - Brian E. Applegate
- Department of Otolaryngology - Head and Neck Surgery, Keck School of Medicine, University of Southern California, 1450 San Pablo Street, Suite 5708, Los Angeles, CA 90033, USA
- Department of Biomedical Engineering, University of Southern California, 1042 Downey Way, Denney Research Center (DRB) 140, Los Angeles, CA 90089, USA
| |
Collapse
|
8
|
Chen T, Rohacek AM, Caporizzo M, Nankali A, Smits JJ, Oostrik J, Lanting CP, Kücük E, Gilissen C, van de Kamp JM, Pennings RJE, Rakowiecki SM, Kaestner KH, Ohlemiller KK, Oghalai JS, Kremer H, Prosser BL, Epstein DJ. Cochlear supporting cells require GAS2 for cytoskeletal architecture and hearing. Dev Cell 2021; 56:1526-1540.e7. [PMID: 33964205 PMCID: PMC8137675 DOI: 10.1016/j.devcel.2021.04.017] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 02/01/2021] [Accepted: 04/16/2021] [Indexed: 11/16/2022]
Abstract
In mammals, sound is detected by mechanosensory hair cells that are activated in response to vibrations at frequency-dependent positions along the cochlear duct. We demonstrate that inner ear supporting cells provide a structural framework for transmitting sound energy through the cochlear partition. Humans and mice with mutations in GAS2, encoding a cytoskeletal regulatory protein, exhibit hearing loss due to disorganization and destabilization of microtubule bundles in pillar and Deiters' cells, two types of inner ear supporting cells with unique cytoskeletal specializations. Failure to maintain microtubule bundle integrity reduced supporting cell stiffness, which in turn altered cochlear micromechanics in Gas2 mutants. Vibratory responses to sound were measured in cochleae from live mice, revealing defects in the propagation and amplification of the traveling wave in Gas2 mutants. We propose that the microtubule bundling activity of GAS2 imparts supporting cells with mechanical properties for transmitting sound energy through the cochlea.
Collapse
Affiliation(s)
- Tingfang Chen
- Department of Genetics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Alex M Rohacek
- Department of Genetics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Matthew Caporizzo
- Department of Physiology, Pennsylvania Muscle Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Amir Nankali
- The Caruso Department of Otolaryngology-Head and Neck Surgery, University of Southern California, Los Angeles, CA, USA
| | - Jeroen J Smits
- Department of Otorhinolaryngology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Jaap Oostrik
- Department of Otorhinolaryngology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Cornelis P Lanting
- Department of Otorhinolaryngology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Erdi Kücük
- Department of Human Genetics, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Christian Gilissen
- Department of Human Genetics, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Jiddeke M van de Kamp
- Department of Clinical Genetics, Amsterdam UMC, Vrije Universiteit Amsterdam, Amsterdam, the Netherlands
| | - Ronald J E Pennings
- Department of Otorhinolaryngology, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Staci M Rakowiecki
- Department of Genetics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Klaus H Kaestner
- Department of Genetics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Kevin K Ohlemiller
- Department of Otolaryngology-Head and Neck Surgery, Washington University School of Medicine, St. Louis, MO, USA
| | - John S Oghalai
- The Caruso Department of Otolaryngology-Head and Neck Surgery, University of Southern California, Los Angeles, CA, USA
| | - Hannie Kremer
- Department of Otorhinolaryngology, Radboud University Medical Center, Nijmegen, the Netherlands; Department of Human Genetics, Radboud University Medical Center, Nijmegen, the Netherlands
| | - Benjamin L Prosser
- Department of Physiology, Pennsylvania Muscle Institute, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Douglas J Epstein
- Department of Genetics, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|