1
|
Rayhan MSA, Talukder A, Rani S, Easin KB, Hossain MA, Biswas PC. Visible diffuse reflectance smartphone spectrometer with high spectral accuracy. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 326:125240. [PMID: 39378831 DOI: 10.1016/j.saa.2024.125240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 09/11/2024] [Accepted: 09/30/2024] [Indexed: 10/10/2024]
Abstract
A smartphone-based spectrometer employing principle of diffuse reflection is reported for the surface analysis of solid samples. The instrument utilizes a thin-film grating to diffract incoming light, while a diffuse reflecting surface projects the image of this diffracted light onto the detector plane. The CMOS camera of smartphone camera directly captures the diffusely reflected photons within its limited field-of-view thus eliminating the need for collection, conditioning and converging optics. The optical setup of the instrument provides facility to calibrate the spectral response considering the nonlinear distribution of the wavelength across the diffraction direction. Additional correction in the detector response at different light intensity results a reduced spectral error with a maximum wavelength resolution of δλ=0.08 nm/pixel in the camera within the spectral range Δλ = (400 - 700) nm. As a proof of the concept, the instrument demonstrates successful detection of color pigments in food samples by absorption measurement of the samples at an average spectral error < 6 %. The distinct absorption peak associated with standard food colors are compared against the absorption profile of unknown food colors used in pastry cake. This field-functional smart analysis with internet connectivity opens opportunity of identifying food adulteration by using toxic chemical colors at the point-of-test and immediate reporting to others. The overall instrument is fabricated by utilizing low-cost and light weight plastic wood to make compact (110 mm × 105 mm × 125 mm), robust, inexpensive (∼$ 50) and suitable for field-portable (∼145 gm) hand-held operation.
Collapse
Affiliation(s)
- Md Sadik Al Rayhan
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Arnab Talukder
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Saptami Rani
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Khaled Bin Easin
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Md Arafat Hossain
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh
| | - Protik Chandra Biswas
- Department of Electrical and Electronic Engineering, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh.
| |
Collapse
|
2
|
Shukla S, Deo BS, Vishwakarma C, Mishra S, Ahirwar S, Sah AN, Pandey K, Singh S, Prasad SN, Padhi AK, Pal M, Panigrahi PK, Pradhan A. A smartphone-based standalone fluorescence spectroscopy tool for cervical precancer diagnosis in clinical conditions. JOURNAL OF BIOPHOTONICS 2024; 17:e202300468. [PMID: 38494870 DOI: 10.1002/jbio.202300468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 02/07/2024] [Accepted: 02/07/2024] [Indexed: 03/19/2024]
Abstract
Real-time prediction about the severity of noncommunicable diseases like cancers is a boon for early diagnosis and timely cure. Optical techniques due to their minimally invasive nature provide better alternatives in this context than the conventional techniques. The present study talks about a standalone, field portable smartphone-based device which can classify different grades of cervical cancer on the basis of the spectral differences captured in their intrinsic fluorescence spectra with the help of AI/ML technique. In this study, a total number of 75 patients and volunteers, from hospitals at different geographical locations of India, have been tested and classified with this device. A classification approach employing a hybrid mutual information long short-term memory model has been applied to categorize various subject groups, resulting in an average accuracy, specificity, and sensitivity of 96.56%, 96.76%, and 94.37%, respectively using 10-fold cross-validation. This exploratory study demonstrates the potential of combining smartphone-based technology with fluorescence spectroscopy and artificial intelligence as a diagnostic screening approach which could enhance the detection and screening of cervical cancer.
Collapse
Affiliation(s)
- Shivam Shukla
- Center for Lasers and Photonics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
| | - Bhaswati Singha Deo
- Center for Lasers and Photonics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
| | - Chaitanya Vishwakarma
- Center for Lasers and Photonics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
| | - Subrata Mishra
- Center for Lasers and Photonics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
| | - Shikha Ahirwar
- PhotoSpIMeDx Pvt. Ltd., Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
| | - Amar Nath Sah
- Department of Biological Sciences and Bioengineering, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
| | - Kiran Pandey
- Obstetrics and Gynecology Department, GSVM Medical College Kanpur, Kanpur, Uttar Pradesh, India
| | - Sweta Singh
- Department of Obstetrics and Gynecology, AIIMS Bhubaneswar, Bhubaneswar, Odisha, India
| | - S N Prasad
- Radiation Oncology Department, J.K. Cancer Institute Kanpur, Kanpur, Uttar Pradesh, India
| | - Ashok Kumar Padhi
- Gynecologic Oncology Department, Acharya Harihar Regional Cancer Research Centre, Cuttack, Odisha, India
| | - Mayukha Pal
- ABB Ability Innovation Center, Asea Brown Boveri Company, Hyderabad, India
| | - Prasanta K Panigrahi
- Department of Physical Sciences, Indian Institute of Science Education and Research Kolkata, Mohanpur, West Bengal, India
- Centre for Quantum Science and Technology, Siksha 'O' Anusandhan University, Bhubaneswar, Odisha, India
| | - Asima Pradhan
- Center for Lasers and Photonics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
- PhotoSpIMeDx Pvt. Ltd., Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
- Department of Physics, Indian Institute of Technology Kanpur, Kanpur, Uttar Pradesh, India
| |
Collapse
|
3
|
Soliman C, Faircloth J, Tu D, Mabbott S, Maitland K, Coté G. Exploring the Clinical Utility of Raman Spectroscopy for Point-of-Care Cardiovascular Disease Biomarker Detection. APPLIED SPECTROSCOPY 2023; 77:1181-1193. [PMID: 37487187 DOI: 10.1177/00037028231187963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/26/2023]
Abstract
A variety of innovative point-of-care (POC) solutions using Raman systems have been explored. However, the vast effort is in assay development, while studies of the characteristics required for Raman spectrometers to function in POC applications are lacking. In this study, we tested and compared the performance of eight commercial Raman spectrometers ranging in size from benchtop Raman microscopes to portable and handheld Raman spectrometers using paper fluidic cartridges, including their ability to detect cardiac troponin I and heart fatty acid binding protein, both of which are well-established biomarkers for evaluating cardiovascular health. Each spectrometer was evaluated in terms of excitation wavelength, laser characteristics, and ease of use to investigate POC utility. We found that the Raman spectrometers equipped with 780 and 785 nm laser sources exhibited a reduced background signal and provided higher sensitivity compared to those with 633 and 638 nm laser sources. Furthermore, the spectrometer equipped with the single acquisition line readout functionality showed improved performance when compared to the point scan spectrometers and allowed measurements to be made faster and easier. The portable and handheld spectrometers also showed similar detection sensitivity to the gold standard instrument. Lastly, we reduced the laser power for the spectrometer with single acquisition line readout capability to explore the system performance at a laser power that change the classification from a Class 3B laser device to a Class 3R device and found that it showed comparable performance. Overall, these findings show that portable Raman spectrometers have the potential to be used in POC settings with accuracy comparable to laboratory-grade instruments, are relatively low-cost, provide fast signal readout, are easy to use, and can facilitate access for underserved communities.
Collapse
Affiliation(s)
- Cyril Soliman
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | | | - Dandan Tu
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
| | - Samuel Mabbott
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
- Texas A&M Engineering Experiment Station, Center for Remote Health Technologies and Systems, College Station, Texas, USA
| | - Kristen Maitland
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
- Texas A&M Engineering Experiment Station, Center for Remote Health Technologies and Systems, College Station, Texas, USA
- Imaging Program, Chan Zuckerberg Initiative, Redwood City, California, USA
| | - Gerard Coté
- Department of Biomedical Engineering, Texas A&M University, College Station, Texas, USA
- Texas A&M Engineering Experiment Station, Center for Remote Health Technologies and Systems, College Station, Texas, USA
| |
Collapse
|
4
|
Shukla S, Vishwakarma C, Sah AN, Ahirwar S, Pandey K, Pradhan A. Smartphone-based fluorescence spectroscopic device for cervical precancer diagnosis: a random forest classification of in vitro data. APPLIED OPTICS 2023; 62:6826-6834. [PMID: 37706817 DOI: 10.1364/ao.496543] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Accepted: 08/11/2023] [Indexed: 09/15/2023]
Abstract
Cervical cancer can be treated and cured if diagnosed at an early stage. Optical devices, developed on smartphone-based platforms, are being tested for this purpose as they are cost-effective, robust, and field portable, showing good efficiency compared to the existing commercial devices. This study reports on the applicability of a 3D printed smartphone-based spectroscopic device (3D-SSD) for the early diagnosis of cervical cancer. The proposed device has the ability to evaluate intrinsic fluorescence (IF) from the collected polarized fluorescence (PF) and elastic-scattering (ES) spectra from cervical tissue samples of different grades. IF spectra of 30 cervical tissue samples have been analyzed and classified using a combination of principal component analysis (PCA) and random forest (RF)-based multi-class classification algorithm with an overall accuracy above 90%. The usage of smartphone for image collection, spectral data analysis, and display makes this device a potential contender for use in clinics as a regular screening tool.
Collapse
|
5
|
Keresteš O, Pohanka M. Affordable Portable Platform for Classic Photometry and Low-Cost Determination of Cholinesterase Activity. BIOSENSORS 2023; 13:599. [PMID: 37366964 DOI: 10.3390/bios13060599] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 05/25/2023] [Accepted: 05/29/2023] [Indexed: 06/28/2023]
Abstract
Excessive use of pesticides could potentially harm the environment for a long time. The reason for this is that the banned pesticide is still likely to be used incorrectly. Carbofuran and other banned pesticides that remain in the environment may also have a negative effect on human beings. In order to provide a better chance for effective environmental screening, this thesis describes a prototype of a photometer tested with cholinesterase to potentially detect pesticides in the environment. The open-source portable photodetection platform uses a color-programmable red, green and blue light-emitting diode (RGB LED) as a light source and a TSL230R light frequency sensor. Acetylcholinesterase from Electrophorus electricus (AChE) with high similarity to human AChE was used for biorecognition. The Ellman method was selected as a standard method. Two analytical approaches were applied: (1) subtraction of the output values after a certain period of time and (2) comparison of the slope values of the linear trend. The optimal preincubation time for carbofuran with AChE was 7 min. The limits of detection for carbofuran were 6.3 nmol/L for the kinetic assay and 13.5 nmol/L for the endpoint assay. The paper demonstrates that the open alternative for commercial photometry is equivalent. The concept based on the OS3P/OS3P could be used as a large-scale screening system.
Collapse
Affiliation(s)
- Ondřej Keresteš
- Faculty of Military Health Sciences, University of Defence, CZ-50001 Hradec Kralove, Czech Republic
| | - Miroslav Pohanka
- Faculty of Military Health Sciences, University of Defence, CZ-50001 Hradec Kralove, Czech Republic
| |
Collapse
|
6
|
Yu Z, Meng R, Deng S, Jia L. An open-source handheld spectrometer for colorimetric and fluorescence analyses. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 287:122072. [PMID: 36375287 DOI: 10.1016/j.saa.2022.122072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 10/28/2022] [Accepted: 10/31/2022] [Indexed: 06/16/2023]
Abstract
Spectrometers are essential analytical devices for analyzing fluid samples in biological, environmental, and disease diagnostic applications. However, the relatively high cost, the lack of portability, and the requirement for a constant power supply of bulky laboratory instruments limit their on-site applications. Herein, a wireless, cost-effective, open-source, and handheld spectrometer was designed and fabricated to realize the colorimetric and fluorescence analyses. It was built from off-the-shelf electronics utilizing 3D printing technology. The assembled device costs as little as $50. It has an overall dimension of 5 × 5 × 8 cm and an overall weight of only 130 g, which can easily fit in the palm of an adult's hand. It can detect light waves in the 405-690 nm range and transmit the read data to the corresponding SpecAnalysis Android application via Bluetooth. The feasibility of the device was demonstrated by the optical detection of Cu(II), bovine serum albumin, and calf thymus DNA. The sensitivity and detection limits of this device were comparable to those of commercial research-grade spectrophotometers and fluorescence spectrometers. The results suggest that the handheld spectrometer can be applied to detect a variety of substances, not limited to quantitative analysis of a specific individual compound.
Collapse
Affiliation(s)
- Zhicheng Yu
- Ministry of Education Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science & Guangzhou Key Laboratory of Spectral Analysis and Functional Probes, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Ruidong Meng
- Ministry of Education Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science & Guangzhou Key Laboratory of Spectral Analysis and Functional Probes, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Suqi Deng
- Ministry of Education Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science & Guangzhou Key Laboratory of Spectral Analysis and Functional Probes, College of Biophotonics, South China Normal University, Guangzhou 510631, China
| | - Li Jia
- Ministry of Education Key Laboratory of Laser Life Science & Guangdong Provincial Key Laboratory of Laser Life Science & Guangzhou Key Laboratory of Spectral Analysis and Functional Probes, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
| |
Collapse
|
7
|
Towards a bionic IoT: Environmental monitoring using smartphone interrogated plant sensors. PLoS One 2023; 18:e0265856. [PMID: 36763639 PMCID: PMC9917261 DOI: 10.1371/journal.pone.0265856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 12/19/2022] [Indexed: 02/12/2023] Open
Abstract
The utilisation of plants directly as quantifiable natural sensors is proposed. A case study measuring surface wettability of Aucuba japonica, or Japanese Laurel, plants using a novel smartphone field interrogator is demonstrated. This plant has been naturalised globally from Asia. Top-down contact angle measurements map wettability on-site and characterise a range of properties impacting plant health, such as aging, solar and UV exposure, and pollution. Leaves at an early age or in the shadow of trees are found to be hydrophobic with contact angle θ ~ 99°, while more mature leaves under sunlight are hydrophilic with θ ~ 79°. Direct UVA irradiation at λ = 365 nm is shown to accelerate aging, changing contact angle of one leaf from slightly hydrophobic at θ ~ 91° to be hydrophilic with θ ~ 87° after 30 min. Leaves growing beside a road with heavy traffic are observed to be substantially hydrophilic, as low as θ ~ 47°, arising from increased wettability with particulate accumulation on the leaf surface. Away from the road, the contact angle increases as high as θ ~ 96°. The results demonstrate that contact angle measurements using a portable diagnostic IoT edge device can be taken into the field for environmental detection, pollution assessment and more. Using an Internet connected smartphone combined with a plant sensor allows multiple measurements at multiple locations together in real-time, potentially enabling tracking of parameter change anywhere where plants are present or introduced. This hybrid integration of widely distributed living organic systems with the Internet marks the beginning of a new bionic Internet-of-things (b-IoT).
Collapse
|
8
|
Di Nonno S, Ulber R. Portuino-A Novel Portable Low-Cost Arduino-Based Photo- and Fluorimeter. SENSORS (BASEL, SWITZERLAND) 2022; 22:7916. [PMID: 36298268 PMCID: PMC9609715 DOI: 10.3390/s22207916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 10/13/2022] [Accepted: 10/13/2022] [Indexed: 06/16/2023]
Abstract
A novel portable low-cost Arduino-controlled photo- and fluorimeter for on-site measurements has been developed. The device uses LEDs as a light source and a phototransistor as a light sensor. The circuit is based on the discharge of a capacitor with the photocurrent from the phototransistor. Validation experiments for absorbance measurements were performed by measuring protein concentration using the Bradford method and measuring phosphate ions in water using a commercial test kit. The emission light of the excited fluorescent dyes rhodamine 6G and calcofluor white was measured to validate the usability of the device as a fluorescence photometer. In all validation experiments, similar correlation coefficients and limit of detection could be achieved with the portable photo- and fluorimeter and a laboratory spectrometer and fluorimeter. Real sample analysis was performed, measuring phosphate concentration in freshwater and concentration of green fluorescent protein, extracted from Escherichia coli.
Collapse
Affiliation(s)
- Sarah Di Nonno
- Correspondence: (S.D.N.); (R.U.); Tel.: +49-631-205-5441 (S.D.N.); +49-631-205-4043 (R.U.)
| | - Roland Ulber
- Correspondence: (S.D.N.); (R.U.); Tel.: +49-631-205-5441 (S.D.N.); +49-631-205-4043 (R.U.)
| |
Collapse
|
9
|
Soliman C, Tu D, Mabbott S, Coté G, Maitland K. Portable, multi-modal Raman and fluorescence spectroscopic platform for point-of-care applications. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220129GR. [PMID: 36163635 PMCID: PMC9510839 DOI: 10.1117/1.jbo.27.9.095006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Accepted: 09/09/2022] [Indexed: 06/16/2023]
Abstract
Significance Point-of-care (POC) platforms utilizing optical biosensing strategies can achieve on-site detection of biomarkers to improve the quality of care for patients in low-resource settings. Aim We aimed to develop a portable, multi-modal spectroscopic platform capable of performing Raman and fluorescence measurements from a single sample site. Approach We designed the spectroscopic platform in OpticStudio using commercial optical components and built the system on a portable optical breadboard. Two excitation and collection arms were utilized to detect the two optical signals. The multi-modal functionality was validated using ratiometric Raman/fluorescence samples, and the potential utility was demonstrated using a model bioassay for cardiac troponin I. Results The designed spectroscopic platform achieved a spectral resolution of 0.67 ± 0.2 nm across the Raman detection range (660 to 770 nm). The ratiometric Raman/fluorescence samples demonstrated no crosstalk between the two detector arms across a gradient of high molar concentrations. Testing of the model bioassay response showed that the integrated approach improved the linearity of the calibration curve from (R2 = 0.977) for the Raman only and (R2 = 0.972) for the fluorescence only to (R2 = 0.988) for the multi-modal approach. Conclusion These findings demonstrate the potential impact of a multi-modal POC spectroscopic platform to improve the sensitivity and robustness necessary for biomarker detection.
Collapse
Affiliation(s)
- Cyril Soliman
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
| | - Dandan Tu
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
| | - Samuel Mabbott
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
- Texas A&M Engineering Experiment Station, Center for Remote Health Technologies and Systems, College Station, Texas, United States
| | - Gerard Coté
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
- Texas A&M Engineering Experiment Station, Center for Remote Health Technologies and Systems, College Station, Texas, United States
| | - Kristen Maitland
- Texas A&M University, Department of Biomedical Engineering, College Station, Texas, United States
- Texas A&M Engineering Experiment Station, Center for Remote Health Technologies and Systems, College Station, Texas, United States
| |
Collapse
|
10
|
Kumar A, Chhibber M. Synthesis and Optimization of Diphenyl Ether‐Based Receptors for the Selective Detection of Cyanide Ions in Neutral Semi‐Aqueous Medium. ChemistrySelect 2022. [DOI: 10.1002/slct.202104386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Ashok Kumar
- School of Chemistry and Biochemistry Thapar Institute of Engineering and Technology Patiala 147004 Punjab India
| | - Manmohan Chhibber
- School of Chemistry and Biochemistry Thapar Institute of Engineering and Technology Patiala 147004 Punjab India
- Thapar School of Liberal Arts and Sciences Thapar Institute of Engineering and Technology Patiala 147004 Punjab India
| |
Collapse
|
11
|
Hossain MA, Brito-Rodriguez B, Sedger LM, Canning J. A Cross-Disciplinary View of Testing and Bioinformatic Analysis of SARS-CoV-2 and Other Human Respiratory Viruses in Pandemic Settings. IEEE ACCESS : PRACTICAL INNOVATIONS, OPEN SOLUTIONS 2021; 9:163716-163734. [PMID: 35582017 PMCID: PMC8843158 DOI: 10.1109/access.2021.3133417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Accepted: 12/04/2021] [Indexed: 05/26/2023]
Abstract
The SARS-Coronavirus-2 (SARS-CoV-2) infectious disease, COVID-19, has spread rapidly, resulting in a global pandemic with significant mortality. The combination of early diagnosis via rapid screening, contact tracing, social distancing and quarantine has helped to control the pandemic. The absence of real time response and diagnosis is a crucial technology shortfall and is a key reason why current contact tracing methods are inadequate to control spread. In contrast, current information technology combined with a new generation of near-real time tests offers consumer-engaged smartphone-based "lab-in-a-phone" internet-of-things (IoT) connected devices that provide increased pandemic monitoring. This review brings together key aspects required to create an entire global diagnostic ecosystem. Cross-disciplinary understanding and integration of both mechanisms and technologies for effective detection, incidence mapping and disease containment in near real-time is summarized. Available measures to monitor and/or sterilize surfaces, next-generation laboratory and smartphone-based diagnostic approaches can be brought together and networked for instant global monitoring that informs Public Health policy. Cloud-based analysis enabling real-time mapping will enable future pandemic control, drive the suppression and elimination of disease spread, saving millions of lives globally. A new paradigm is introduced - scaled and multiple diagnostics for mapping and spreading of a pandemic rather than traditional accumulation of individual measurements. This can do away with the need for ultra-precise and ultra-accurate analysis by taking mass measurements that can relax tolerances and build resilience through networked analytics and informatics, the basis for novel swarm diagnostics. These include addressing ethical standards, local, national and international collaborative engagement, multidisciplinary and analytical measurements and standards, and data handling and storage protocols.
Collapse
Affiliation(s)
- Md Arafat Hossain
- Department of Electrical and Electronic EngineeringKhulna University of Engineering & TechnologyKhulna9203Bangladesh
| | | | - Lisa M. Sedger
- Faculty of ScienceUniversity of Technology Sydney (UTS)SydneyNSW2007Australia
| | - John Canning
- interdisciplinary Photonic Laboratories (iPL), Global Big Data Technologies Centre (GBDTC), Faculty of Engineering and Information TechnologyUniversity of Technology Sydney (UTS)SydneyNSW2007Australia
| |
Collapse
|
12
|
Abstract
During the past few decades, there has been a growing trend towards the use of smartphone-based analysis systems. This is mainly due to its ubiquity, its increasing computing capacity, its relatively low cost and the ability to acquire and process data at the same time. Furthermore, there are many sensors integrated into a smartphone, for example a complementary metal-oxide semiconductor (CMOS) sensor. A CMOS sensor enables optical analysis for example by using it as a colorimeter, photometer or spectrometer. This review explores the current state-of-the-art smartphone-based optical analysis systems in various areas of application. It is organized into three sections, each of which investigates one class of smartphone-based devices: (i) smartphone-based colorimeters (ii) smartphone-based photo- and spectrometers and (iii) smartphone-based fluorimeters.
Collapse
Affiliation(s)
- Sarah Di Nonno
- TU Kaiserslautern, Chair of Bioprocess Engineering, Kaiserslautern, Germany.
| | - Roland Ulber
- TU Kaiserslautern, Chair of Bioprocess Engineering, Kaiserslautern, Germany.
| |
Collapse
|
13
|
Hussain I, Bowden AK. Smartphone-based optical spectroscopic platforms for biomedical applications: a review [Invited]. BIOMEDICAL OPTICS EXPRESS 2021; 12:1974-1998. [PMID: 33996211 PMCID: PMC8086480 DOI: 10.1364/boe.416753] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/10/2020] [Revised: 02/25/2021] [Accepted: 03/04/2021] [Indexed: 05/15/2023]
Abstract
Rapid advancements in smartphone technology have enabled the integration of many optical detection techniques that leverage the embedded functional components and software platform of these sophisticated devices. Over the past few years, several research groups have developed high-resolution smartphone-based optical spectroscopic platforms and demonstrated their usability in different biomedical applications. Such platforms provide unprecedented opportunity to develop point-of-care diagnostics systems, especially for resource-constrained environments. In this review, we discuss the development of smartphone systems for optical spectroscopy and highlight current challenges and potential solutions to improve the scope for their future adaptability.
Collapse
Affiliation(s)
- Iftak Hussain
- Vanderbilt University,
Vanderbilt Biophotonics Center, Department of Biomedical Engineering,
410 24th Street South, Nashville, TN 37232, USA
| | - Audrey K. Bowden
- Vanderbilt University,
Vanderbilt Biophotonics Center, Department of Biomedical Engineering,
410 24th Street South, Nashville, TN 37232, USA
| |
Collapse
|
14
|
Huang W, Luo S, Yang D, Zhang S. Applications of smartphone-based near-infrared (NIR) imaging, measurement, and spectroscopy technologies to point-of-care (POC) diagnostics. J Zhejiang Univ Sci B 2021; 22:171-189. [PMID: 33719223 DOI: 10.1631/jzus.b2000388] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
The role of point-of-care (POC) diagnostics is important in public health. With the support of smartphones, POC diagnostic technologies can be greatly improved. This opportunity has arisen from not only the large number and fast spread of cell-phones across the world but also their improved imaging/diagnostic functions. As a tool, the smartphone is regarded as part of a compact, portable, and low-cost system for real-time POC, even in areas with few resources. By combining near-infrared (NIR) imaging, measurement, and spectroscopy techniques, pathogens can be detected with high sensitivity. The whole process is rapid, accurate, and low-cost, and will set the future trend for POC diagnostics. In this review, the development of smartphone-based NIR fluorescent imaging technology was described, and the quality and potential of POC applications were discussed.
Collapse
Affiliation(s)
- Wenjing Huang
- Ningbo Research Institute, Zhejiang University, Ningbo 315100, China.,Department of Bioengineering, School of Engineering, The University of Tokyo, Tokyo 113-8656, Japan
| | - Shenglin Luo
- Institute of Combined Injury, State Key Laboratory of Trauma, Burn and Combined Injury, College of Preventive Medicine, Third Military Medical University, Chongqing 400038, China.,Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Charlestown 02129, USA
| | - Dong Yang
- Division of Biomedical Engineering, Renal Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge 02139, USA
| | - Sheng Zhang
- Ningbo Research Institute, Zhejiang University, Ningbo 315100, China. .,State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China.
| |
Collapse
|
15
|
Chen G, Chai HH, Fu JJ, Yu L, Fang C. A smartphone-supported portable micro-spectroscopy/imaging system to characterize morphology and spectra of samples at the microscale. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:4166-4171. [PMID: 32785298 DOI: 10.1039/d0ay00945h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A smartphone-based analysis system is favored for point-of-care testing applications. The present work proposes a novel micro-spectroscopy/imaging system comprising a portable spectrometer as an optical sensor and a compact homemade microscope to acquire the image and spectra of micron-scale regions. Protein concentration quantification based on the bicinchoninic acid method was demonstrated with the proposed micro-spectroscopy/imaging system to analyse the spectrometer signals. Morphologies of onion endothelial and human breast cancer cells, used as biological sample models, were characterized to demonstrate the microscopic imaging capacity of the device. The ability to simultaneously obtain morphological and spectral information using the proposed portable device was demonstrated by examining the 10 μm sub-pixels of a smartphone screen. These results highlight the potential for adopting a smartphone-based micro-spectroscopy/imaging system for point-of-care testing.
Collapse
Affiliation(s)
- Gang Chen
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Hui Hui Chai
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Jing Jing Fu
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Ling Yu
- Institute for Clean energy & Advanced Materials, School of Materials & Energy, Southwest University, Chongqing 400715, China.
| | - Can Fang
- School of Computer and Information Science, Southwest University, Chongqing 400715, China.
| |
Collapse
|
16
|
Matinrad F, Kompany-Zareh M, Omidikia N, Dadashi M. Systematic investigation of the measurement error structure in a smartphone-based spectrophotometer. Anal Chim Acta 2020; 1129:98-107. [PMID: 32891395 DOI: 10.1016/j.aca.2020.06.066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 05/28/2020] [Accepted: 06/25/2020] [Indexed: 10/23/2022]
Abstract
Smartphones are state-of-the-art devices with several interesting features which make them promising for analytical purposes. After modification to a spectrophotometer (smart spectrophotometer), they can be utilized for the quantitative or qualitative applications. Although smartphones have widely been applied for sensing∖biosensing purposes, the error structure/type of their outputs remained unexplored. Error structure information values the objects/channels in a given data set and variables have the same importance when the noise has identical independent distribution (i.i.d). Otherwise, error structure weights them for further data analysis. In this contribution, a smartphone-based spectrophotometer was constructed integrating simple optical elements-a tungsten lamp as source and a piece of digital versatile disc (DVD) as a reflecting diffraction grating to investigate the error sources of the smartphone-spectrophotometer. For this purpose, error covariance matrices (ECMs) were calculated using a series of replication capturing error information. Afterwards, PCA and MCR-ALS were employed for the decomposition of the ECMs and resolved profiles were translated to the error types. Finally, proportional error as a heteroscedastic noise was highlighted as the most important source of variation in the error structure of the smartphone-based spectrophotometer.
Collapse
Affiliation(s)
- Fereshteh Matinrad
- Chemistry Department, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran
| | - Mohsen Kompany-Zareh
- Chemistry Department, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran; Trace Analysis Research Centre, Department of Chemistry, Dalhousie University, PO Box 15000, Halifax, NS B3H 4R2, Canada.
| | - Nematollah Omidikia
- University of Sistan and Baluchestan, Department of Chemistry, Faculty of Science, P.O. Box 98135-674, Zahedan, Iran
| | - Mahsa Dadashi
- Chemistry Department, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran
| |
Collapse
|
17
|
Costa E, Climent E, Ast S, Weller MG, Canning J, Rurack K. Development of a lateral flow test for rapid pyrethroid detection using antibody-gated indicator-releasing hybrid materials. Analyst 2020; 145:3490-3494. [DOI: 10.1039/d0an00319k] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The employment of type-I pyrethroids for airplane disinfection in recent years underlines the necessity to develop sensing schemes for the rapid detection of these pesticides directly at the point-of-use.
Collapse
Affiliation(s)
- Elena Costa
- Bundesanstalt für Materialforschung und – prüfung (BAM)
- D-12489 Berlin
- Germany
| | - Estela Climent
- Bundesanstalt für Materialforschung und – prüfung (BAM)
- D-12489 Berlin
- Germany
| | - Sandra Ast
- Australian Sensing and Identification Systems Pty Ltd
- Sydney
- Australia
| | - Michael G. Weller
- Bundesanstalt für Materialforschung und – prüfung (BAM)
- D-12489 Berlin
- Germany
| | - John Canning
- Interdisciplinary Photonics Laboratories
- School of Electrical & Data Engineering
- University of Technology Sydney
- Sydney
- Australia
| | - Knut Rurack
- Bundesanstalt für Materialforschung und – prüfung (BAM)
- D-12489 Berlin
- Germany
| |
Collapse
|
18
|
Stuart MB, McGonigle AJS, Willmott JR. Hyperspectral Imaging in Environmental Monitoring: A Review of Recent Developments and Technological Advances in Compact Field Deployable Systems. SENSORS 2019; 19:s19143071. [PMID: 31336796 PMCID: PMC6678368 DOI: 10.3390/s19143071] [Citation(s) in RCA: 64] [Impact Index Per Article: 12.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 06/26/2019] [Accepted: 07/09/2019] [Indexed: 12/21/2022]
Abstract
The development and uptake of field deployable hyperspectral imaging systems within environmental monitoring represents an exciting and innovative development that could revolutionize a number of sensing applications in the coming decades. In this article we focus on the successful miniaturization and improved portability of hyperspectral sensors, covering their application both from aerial and ground-based platforms in a number of environmental application areas, highlighting in particular the recent implementation of low-cost consumer technology in this context. At present, these devices largely complement existing monitoring approaches, however, as technology continues to improve, these units are moving towards reaching a standard suitable for stand-alone monitoring in the not too distant future. As these low-cost and light-weight devices are already producing scientific grade results, they now have the potential to significantly improve accessibility to hyperspectral monitoring technology, as well as vastly proliferating acquisition of such datasets.
Collapse
Affiliation(s)
- Mary B Stuart
- Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield S1 4DE, UK
| | - Andrew J S McGonigle
- Department of Geography, University of Sheffield, Sheffield S10 2TN, UK
- School of Geosciences, The University of Sydney, Sydney, NSW 2006, Australia
- Faculty of Health, Engineering and Sciences, University of Southern Queensland, Toowoomba, QLD 4350, Australia
| | - Jon R Willmott
- Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield S1 4DE, UK.
| |
Collapse
|
19
|
Abstract
Until very recently, handheld spectrometers were the domain of major analytical and security instrument companies, with turnkey analyzers using spectroscopic techniques from X-ray fluorescence (XRF) for elemental analysis (metals), to Raman, mid-infrared, and near-infrared (NIR) for molecular analysis (mostly organics). However, the past few years have seen rapid changes in this landscape with the introduction of handheld laser-induced breakdown spectroscopy (LIBS), smartphone spectroscopy focusing on medical diagnostics for low-resource areas, commercial engines that a variety of companies can build up into products, hyphenated or dual technology instruments, low-cost visible-shortwave NIR instruments selling directly to the public, and, most recently, portable hyperspectral imaging instruments. Successful handheld instruments are designed to give answers to non-scientist operators; therefore, their developers have put extensive resources into reliable identification algorithms, spectroscopic libraries or databases, and qualitative and quantitative calibrations. As spectroscopic instruments become smaller and lower cost, "engines" have emerged, leading to the possibility of being incorporated in consumer devices and smart appliances, part of the Internet of Things (IOT). This review outlines the technologies used in portable spectroscopy, discusses their applications, both qualitative and quantitative, and how instrument developers and vendors have approached giving actionable answers to non-scientists. It outlines concerns on crowdsourced data, especially for heterogeneous samples, and finally looks towards the future in areas like IOT, emerging technologies for instruments, and portable hyphenated and hyperspectral instruments.
Collapse
|
20
|
Hussain I, Nath P. Design of a 3D printed compact interferometric system and required phone application for small angular measurements. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:103111. [PMID: 30399881 DOI: 10.1063/1.5040189] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2018] [Accepted: 10/06/2018] [Indexed: 06/08/2023]
Abstract
A 3D printed smartphone based interferometric system is proposed, and its usability has been demonstrated by measuring small angular rotations. All necessary fringe processing and data analysis have been performed within the phone itself using custom designed application developed in an android platform. The main objective of the proposed work is to demonstrate the usability of modern smartphone and 3D printing technology for optical interferometric applications. The smartphone camera has been used to record the interference fringes which has been formed due to the change in the optical path difference (OPD) between light rays reflected from the top and bottom surface of a microscopic glass slide. The angular variation of the slide causes a detectable change in the OPD between the interfering beams which subsequently would cause a variation in the fringe pattern. By evaluating necessary interferometric parameters, small angular rotation can be computed within the smartphone application. With the designed smartphone based interferometric system, angular rotation as small as 0.02° can be measured accurately and reliably having a dynamic range of -3.68° to 3.68°. Due to the involvement of the smartphone as a platform for recording as well as onboard fringe processing, the designed interferometric system can be visualized as a truly field portable tool for different optical metrological applications.
Collapse
Affiliation(s)
- I Hussain
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Nappam 78402, India
| | - P Nath
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Nappam 78402, India
| |
Collapse
|
21
|
Hossain MA, Canning J, Yu Z, Ast S, Rutledge PJ, Wong JKH, Jamalipour A, Crossley MJ. Time-resolved and temperature tuneable measurements of fluorescent intensity using a smartphone fluorimeter. Analyst 2018; 142:1953-1961. [PMID: 28474014 DOI: 10.1039/c7an00535k] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A smartphone fluorimeter capable of time-based fluorescence intensity measurements at various temperatures is reported. Excitation is provided by an integrated UV LED (λex = 370 nm) and detection obtained using the in-built CMOS camera. A Peltier is integrated to allow measurements of the intensity over T = 10 to 40 °C. All components are controlled using a smartphone battery powered Arduino microcontroller and a customised Android application that allows sequential fluorescence imaging and quantification every δt = 4 seconds. The temperature dependence of fluorescence intensity for four emitters (rhodamine B, rhodamine 6G, 5,10,15,20-tetraphenylporphyrin and 6-(1,4,8,11-tetraazacyclotetradecane)2-ethyl-naphthalimide) are characterised. The normalised fluorescence intensity over time of the latter chemosensor dye complex in the presence of Zn2+ is observed to accelerate with an increasing rate constant, k = 1.94 min-1 at T = 15 °C and k = 3.64 min-1 at T = 30 °C, approaching a factor of ∼2 with only a change in temperature of ΔT = 15 °C. Thermally tuning these twist and bend associated rates to optimise sensor approaches and device applications is proposed.
Collapse
Affiliation(s)
- Md Arafat Hossain
- interdisciplinary Photonics Laboratories, School of Electrical and Data Engineering, University of Technology, Sydney (UTS), NSW 2007. Australia.
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Kılıç V, Alankus G, Horzum N, Mutlu AY, Bayram A, Solmaz ME. Single-Image-Referenced Colorimetric Water Quality Detection Using a Smartphone. ACS OMEGA 2018; 3:5531-5536. [PMID: 31458756 PMCID: PMC6641965 DOI: 10.1021/acsomega.8b00625] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Accepted: 05/10/2018] [Indexed: 05/25/2023]
Abstract
In this paper, we present a smartphone platform for colorimetric water quality detection based on the use of built-in camera for capturing a single-use reference image. A custom-developed app processes this image for training and creates a reference model to be used later in real experimental conditions to calculate the concentration of the unknown solution. This platform has been tested on four different water quality colorimetric assays with various concentration levels, and results show that the presented platform provides approximately 100% accuracy for colorimetric assays with noticeable color difference. This portable, cost-effective, and user-friendly platform is promising for application in water quality monitoring.
Collapse
Affiliation(s)
- Volkan Kılıç
- Department
of Electrical and Electronics Engineering, Department of Engineering
Sciences, and Department of Material Science and Engineering, Izmir Katip Celebi University, Balatcik Campus, Cigli, Izmir 35620, Turkey
| | - Gazihan Alankus
- Department
of Mechatronics Engineering, Izmir University
of Economics, Balcova, 35330 Izmir, Turkey
| | - Nesrin Horzum
- Department
of Electrical and Electronics Engineering, Department of Engineering
Sciences, and Department of Material Science and Engineering, Izmir Katip Celebi University, Balatcik Campus, Cigli, Izmir 35620, Turkey
| | - Ali Y. Mutlu
- Department
of Electrical and Electronics Engineering, Department of Engineering
Sciences, and Department of Material Science and Engineering, Izmir Katip Celebi University, Balatcik Campus, Cigli, Izmir 35620, Turkey
| | - Abdullah Bayram
- Department
of Electrical and Electronics Engineering, Department of Engineering
Sciences, and Department of Material Science and Engineering, Izmir Katip Celebi University, Balatcik Campus, Cigli, Izmir 35620, Turkey
| | - Mehmet E. Solmaz
- Department
of Electrical and Electronics Engineering, Department of Engineering
Sciences, and Department of Material Science and Engineering, Izmir Katip Celebi University, Balatcik Campus, Cigli, Izmir 35620, Turkey
| |
Collapse
|
23
|
Zhao Y, Yang M, Fu Q, Ouyang H, Wen W, Song Y, Zhu C, Lin Y, Du D. A Nanozyme- and Ambient Light-Based Smartphone Platform for Simultaneous Detection of Dual Biomarkers from Exposure to Organophosphorus Pesticides. Anal Chem 2018; 90:7391-7398. [DOI: 10.1021/acs.analchem.8b00837] [Citation(s) in RCA: 91] [Impact Index Per Article: 15.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Affiliation(s)
- Yuting Zhao
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
- Key Laboratory of Pesticide & Chemical Biology, Ministry of Education, College of Chemistry, Central China Normal University, Wuhan 430079, People’s Republic of China
| | - Mingming Yang
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Qiangqiang Fu
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Hui Ouyang
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Wei Wen
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Yang Song
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Chengzhou Zhu
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Yuehe Lin
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Dan Du
- School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| |
Collapse
|
24
|
Ulep TH, Yoon JY. Challenges in paper-based fluorogenic optical sensing with smartphones. NANO CONVERGENCE 2018; 5:14. [PMID: 29755926 PMCID: PMC5937860 DOI: 10.1186/s40580-018-0146-1] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2018] [Accepted: 04/27/2018] [Indexed: 05/23/2023]
Abstract
Application of optically superior, tunable fluorescent nanotechnologies have long been demonstrated throughout many chemical and biological sensing applications. Combined with microfluidics technologies, i.e. on lab-on-a-chip platforms, such fluorescent nanotechnologies have often enabled extreme sensitivity, sometimes down to single molecule level. Within recent years there has been a peak interest in translating fluorescent nanotechnology onto paper-based platforms for chemical and biological sensing, as a simple, low-cost, disposable alternative to conventional silicone-based microfluidic substrates. On the other hand, smartphone integration as an optical detection system as well as user interface and data processing component has been widely attempted, serving as a gateway to on-board quantitative processing, enhanced mobility, and interconnectivity with informational networks. Smartphone sensing can be integrated to these paper-based fluorogenic assays towards demonstrating extreme sensitivity as well as ease-of-use and low-cost. However, with these emerging technologies there are always technical limitations that must be addressed; for example, paper's autofluorescence that perturbs fluorogenic sensing; smartphone flash's limitations in fluorescent excitation; smartphone camera's limitations in detecting narrow-band fluorescent emission, etc. In this review, physical optical setups, digital enhancement algorithms, and various fluorescent measurement techniques are discussed and pinpointed as areas of opportunities to further improve paper-based fluorogenic optical sensing with smartphones.
Collapse
Affiliation(s)
- Tiffany-Heather Ulep
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721 USA
| | - Jeong-Yeol Yoon
- Department of Biomedical Engineering, The University of Arizona, Tucson, AZ 85721 USA
| |
Collapse
|
25
|
Zarei M. Infectious pathogens meet point-of-care diagnostics. Biosens Bioelectron 2018; 106:193-203. [PMID: 29428589 DOI: 10.1016/j.bios.2018.02.007] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2017] [Revised: 01/31/2018] [Accepted: 02/01/2018] [Indexed: 12/12/2022]
Abstract
The field of point-of-care (POC) diagnostics provides the rapid diagnosis of infectious diseases which is essential and critical for improving the general public health in resource-limited settings. POC platforms offer many advantages for detection of various pathogens including portability, automation, speed, cost, and efficiency. In this review, we provide an overview of the recent trends for POC diagnostics of infectious diseases with focus on portable platforms. We review here the present status of POC platforms, emphasizing in period of the past three years, then extrapolate their advance into the future applications for diagnosis of infectious pathogens.
Collapse
Affiliation(s)
- Mohammad Zarei
- Department of Chemical and Civil Engineering, University of Kurdistan, Sanandaj, P.O. Box 66177, Kurdistan Province 66618-36336, Iran.
| |
Collapse
|
26
|
McGonigle AJS, Wilkes TC, Pering TD, Willmott JR, Cook JM, Mims FM, Parisi AV. Smartphone Spectrometers. SENSORS (BASEL, SWITZERLAND) 2018; 18:E223. [PMID: 29342899 PMCID: PMC5796291 DOI: 10.3390/s18010223] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 01/05/2018] [Accepted: 01/11/2018] [Indexed: 12/26/2022]
Abstract
Smartphones are playing an increasing role in the sciences, owing to the ubiquitous proliferation of these devices, their relatively low cost, increasing processing power and their suitability for integrated data acquisition and processing in a 'lab in a phone' capacity. There is furthermore the potential to deploy these units as nodes within Internet of Things architectures, enabling massive networked data capture. Hitherto, considerable attention has been focused on imaging applications of these devices. However, within just the last few years, another possibility has emerged: to use smartphones as a means of capturing spectra, mostly by coupling various classes of fore-optics to these units with data capture achieved using the smartphone camera. These highly novel approaches have the potential to become widely adopted across a broad range of scientific e.g., biomedical, chemical and agricultural application areas. In this review, we detail the exciting recent development of smartphone spectrometer hardware, in addition to covering applications to which these units have been deployed, hitherto. The paper also points forward to the potentially highly influential impacts that such units could have on the sciences in the coming decades.
Collapse
Affiliation(s)
- Andrew J S McGonigle
- Department of Geography, University of Sheffield, Sheffield S10 2TN, UK.
- School of Geosciences, The University of Sydney, Sydney 2006, Australia.
| | - Thomas C Wilkes
- Department of Geography, University of Sheffield, Sheffield S10 2TN, UK.
| | - Tom D Pering
- Department of Geography, University of Sheffield, Sheffield S10 2TN, UK.
| | - Jon R Willmott
- Department of Electronic and Electrical Engineering, University of Sheffield, Sheffield S1 4DE, UK.
| | - Joseph M Cook
- Department of Geography, University of Sheffield, Sheffield S10 2TN, UK.
| | | | - Alfio V Parisi
- Faculty of Health, Engineering and Sciences, University of Southern Queensland, Toowoomba, QLD 4350, Australia.
| |
Collapse
|
27
|
Advances in point-of-care technologies for molecular diagnostics. Biosens Bioelectron 2017; 98:494-506. [DOI: 10.1016/j.bios.2017.07.024] [Citation(s) in RCA: 102] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2017] [Revised: 07/06/2017] [Accepted: 07/10/2017] [Indexed: 12/31/2022]
|
28
|
Wilkes TC, McGonigle AJS, Willmott JR, Pering TD, Cook JM. Low-cost 3D printed 1 nm resolution smartphone sensor-based spectrometer: instrument design and application in ultraviolet spectroscopy. OPTICS LETTERS 2017; 42:4323-4326. [PMID: 29088154 DOI: 10.1364/ol.42.004323] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2017] [Accepted: 09/11/2017] [Indexed: 06/07/2023]
Abstract
We report on the development of a low-cost spectrometer, based on off-the-shelf optical components, a 3D printed housing, and a modified Raspberry Pi camera module. With a bandwidth and spectral resolution of ≈60 nm and 1 nm, respectively, this device was designed for ultraviolet (UV) remote sensing of atmospheric sulphur dioxide (SO2), ≈310 nm. To the best of our knowledge, this is the first report of both a UV spectrometer and a nanometer resolution spectrometer based on smartphone sensor technology. The device performance was assessed and validated by measuring column amounts of SO2 within quartz cells with a differential optical absorption spectroscopy processing routine. This system could easily be reconfigured to cover other UV-visible-near-infrared spectral regions, as well as alternate spectral ranges and/or linewidths. Hence, our intention is also to highlight how this framework could be applied to build bespoke, low-cost, spectrometers for a range of scientific applications.
Collapse
|
29
|
Long KD, Woodburn EV, Le HM, Shah UK, Lumetta SS, Cunningham BT. Multimode smartphone biosensing: the transmission, reflection, and intensity spectral (TRI)-analyzer. LAB ON A CHIP 2017; 17:3246-3257. [PMID: 28752875 PMCID: PMC5614857 DOI: 10.1039/c7lc00633k] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
We demonstrate a smartphone-integrated handheld detection instrument capable of utilizing the internal rear-facing camera as a high-resolution spectrometer for measuring the colorimetric absorption spectrum, fluorescence emission spectrum, and resonant reflection spectrum from a microfluidic cartridge inserted into the measurement light path. Under user selection, the instrument gathers light from either the white "flash" LED of the smartphone or an integrated green laser diode to direct illumination into a liquid test sample or onto a photonic crystal biosensor. Light emerging from each type of assay is gathered via optical fiber and passed through a diffraction grating placed directly over the smartphone camera to generate spectra from the assay when an image is collected. Each sensing modality is associated with a unique configuration of a microfluidic "stick" containing a linear array of liquid chambers that are swiped through the instrument while the smartphone captures video and the software automatically selects spectra representative of each compartment. The system is demonstrated for representative assays in the field of point-of-care (POC) maternal and infant health: an ELISA assay for the fetal fibronectin protein used as an indicator for pre-term birth and a fluorescent assay for phenylalanine as an indicator for phenylketonuria. In each case, the TRI-analyzer is capable of achieving limits of detection that are comparable to those obtained for the same assay measured with a conventional laboratory microplate reader, demonstrating the flexibility of the system to serve as a platform for rapid, simple translation of existing commercially available biosensing assays to a POC setting.
Collapse
Affiliation(s)
- Kenneth D Long
- Department of Bioengineering, Micro and Nano Technology Laboratory, University of Illinois at Urbana-Champaign, 208 N. Wright Street, Urbana, IL 61801, USA.
| | | | | | | | | | | |
Collapse
|
30
|
Smartphone based optical spectrometer for diffusive reflectance spectroscopic measurement of hemoglobin. Sci Rep 2017; 7:12224. [PMID: 28939898 PMCID: PMC5610341 DOI: 10.1038/s41598-017-12482-5] [Citation(s) in RCA: 53] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Accepted: 09/07/2017] [Indexed: 11/25/2022] Open
Abstract
We report a miniature, visible to near infrared G-Fresnel spectrometer that contains a complete spectrograph system, including the detection hardware and connects with a smartphone through a microUSB port for operational control. The smartphone spectrometer is able to achieve a resolution of ~5 nm in a wavelength range from 400 nm to 1000 nm. We further developed a diffuse reflectance spectroscopy system using the smartphone spectrometer and demonstrated the capability of hemoglobin measurement. Proof of concept studies of tissue phantoms yielded a mean error of 9.2% on hemoglobin concentration measurement, comparable to that obtained with a commercial benchtop spectrometer. The smartphone G-Fresnel spectrometer and the diffuse reflectance spectroscopy system can potentially enable new point-of-care opportunities, such as cancer screening.
Collapse
|
31
|
Dutra G, Canning J, Padden W, Martelli C, Dligatch S. Large area optical mapping of surface contact angle. OPTICS EXPRESS 2017; 25:21127-21144. [PMID: 29041520 DOI: 10.1364/oe.25.021127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Accepted: 06/29/2017] [Indexed: 06/07/2023]
Abstract
Top-down contact angle measurements have been validated and confirmed to be as good if not more reliable than side-based measurements. A range of samples, including industrially relevant materials for roofing and printing, has been compared. Using the top-down approach, mapping in both 1-D and 2-D has been demonstrated. The method was applied to study the change in contact angle as a function of change in silver (Ag) nanoparticle size controlled by thermal evaporation. Large area mapping reveals good uniformity for commercial Aspen paper coated with black laser printer ink. A demonstration of the forensic and chemical analysis potential in 2-D is shown by uncovering the hidden CsF initials made with mineral oil on the coated Aspen paper. The method promises to revolutionize nanoscale characterization and industrial monitoring as well as chemical analyses by allowing rapid contact angle measurements over large areas or large numbers of samples in ways and times that have not been possible before.
Collapse
|
32
|
Dutta S, Saikia GP, Sarma DJ, Gupta K, Das P, Nath P. Protein, enzyme and carbohydrate quantification using smartphone through colorimetric digitization technique. JOURNAL OF BIOPHOTONICS 2017; 10:623-633. [PMID: 27243385 DOI: 10.1002/jbio.201500329] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Revised: 05/02/2016] [Accepted: 05/04/2016] [Indexed: 06/05/2023]
Abstract
In this paper the utilization of smartphone as a detection platform for colorimetric quantification of biological macromolecules has been demonstrated. Using V-channel of HSV color space, the quantification of BSA protein, catalase enzyme and carbohydrate (using D-glucose) have been successfully investigated. A custom designed android application has been developed for estimating the total concentration of biological macromolecules. The results have been compared with that of a standard spectrophotometer which is generally used for colorimetric quantification in laboratory settings by measuring its absorbance at a specific wavelength. The results obtained with the designed sensor is found to be similar when compared with the spectrophotometer data. The designed sensor is low cost, robust and we envision that it could promote diverse fields of bio-analytical investigations. Schematic illustration of the smartphone sensing mechanism for colorimetric analysis of biomolecular samples.
Collapse
Affiliation(s)
- Sibasish Dutta
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Napaam, Assam, 784028, India
| | - Gunjan Prasad Saikia
- Department of Computer science, Guwahati University, Gopinath Bordoloi Nagar, Guwahati, Assam, 781014, India
| | - Dhruva Jyoti Sarma
- Applied Biochemistry Laboratory, Department of Molecular Biology and Biotechnology, Tezpur University, Napaam, Assam, 784028, India
| | - Kuldeep Gupta
- Applied Microbiology and Biotechnology Laboratory, Department of Molecular Biology and Biotechnology, Tezpur University, Napaam, Assam, 784028, India
| | - Priyanka Das
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Napaam, Assam, 784028, India
| | - Pabitra Nath
- Applied Photonics and Nanophotonics Laboratory, Department of Physics, Tezpur University, Napaam, Assam, 784028, India
| |
Collapse
|
33
|
Recent Advances in Macrocyclic Fluorescent Probes for Ion Sensing. Molecules 2017; 22:molecules22020200. [PMID: 28125069 DOI: 10.3390/molecules22020200] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2016] [Revised: 01/13/2017] [Accepted: 01/16/2017] [Indexed: 12/18/2022] Open
Abstract
Small-molecule fluorescent probes play a myriad of important roles in chemical sensing. Many such systems incorporating a receptor component designed to recognise and bind a specific analyte, and a reporter or transducer component which signals the binding event with a change in fluorescence output have been developed. Fluorescent probes use a variety of mechanisms to transmit the binding event to the reporter unit, including photoinduced electron transfer (PET), charge transfer (CT), Förster resonance energy transfer (FRET), excimer formation, and aggregation induced emission (AIE) or aggregation caused quenching (ACQ). These systems respond to a wide array of potential analytes including protons, metal cations, anions, carbohydrates, and other biomolecules. This review surveys important new fluorescence-based probes for these and other analytes that have been reported over the past five years, focusing on the most widely exploited macrocyclic recognition components, those based on cyclam, calixarenes, cyclodextrins and crown ethers; other macrocyclic and non-macrocyclic receptors are also discussed.
Collapse
|
34
|
Wang LJ, Chang YC, Sun R, Li L. A multichannel smartphone optical biosensor for high-throughput point-of-care diagnostics. Biosens Bioelectron 2017; 87:686-692. [DOI: 10.1016/j.bios.2016.09.021] [Citation(s) in RCA: 87] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Revised: 09/06/2016] [Accepted: 09/07/2016] [Indexed: 02/07/2023]
|
35
|
Wen Y, Kuang D, Huang J, Zhang Y. Microaxicave colour analysis system for fluoride concentration using a smartphone. RSC Adv 2017. [DOI: 10.1039/c7ra07727k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Layout of our fluoride measurement system and the correlation between the concentration of fluoride and the peak of value–hue curves.
Collapse
Affiliation(s)
- Yuxiang Wen
- Institute of Modern Optics
- The Key Laboratory of Optical Information Science and Technology of the Education Ministry of China
- Nankai University
- Tianjin
- China
| | - Dengfeng Kuang
- Institute of Modern Optics
- The Key Laboratory of Optical Information Science and Technology of the Education Ministry of China
- Nankai University
- Tianjin
- China
| | - Jinhui Huang
- Sino-Canada Joint R&D Centre for Water and Environment Safety
- College of Environmental Science and Engineering
- Nankai University
- Tianjin
- China
| | - Yi Zhang
- Sino-Canada Joint R&D Centre for Water and Environment Safety
- College of Environmental Science and Engineering
- Nankai University
- Tianjin
- China
| |
Collapse
|
36
|
Hussain I, Ahamad KU, Nath P. Low-Cost, Robust, and Field Portable Smartphone Platform Photometric Sensor for Fluoride Level Detection in Drinking Water. Anal Chem 2016; 89:767-775. [PMID: 27982569 DOI: 10.1021/acs.analchem.6b03424] [Citation(s) in RCA: 88] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Groundwater is the major source of drinking water for people living in rural areas of India. Pollutants such as fluoride in groundwater may be present in much higher concentration than the permissible limit. Fluoride does not give any visible coloration to water, and hence, no effort is made to remove or reduce the concentration of this chemical present in drinking water. This may lead to a serious health hazard for those people taking groundwater as their primary source of drinking water. Sophisticated laboratory grade tools such as ion selective electrodes (ISE) and portable spectrophotometers are commercially available for in-field detection of fluoride level in drinking water. However, such tools are generally expensive and require expertise to handle. In this paper, we demonstrate the working of a low cost, robust, and field portable smartphone platform fluoride sensor that can detect and analyze fluoride concentration level in drinking water. For development of the proposed sensor, we utilize the ambient light sensor (ALS) of the smartphone as light intensity detector and its LED flash light as an optical source. An android application "FSense" has been developed which can detect and analyze the fluoride concentration level in water samples. The custom developed application can be used for sharing of in-field sensing data from any remote location to the central water quality monitoring station. We envision that the proposed sensing technique could be useful for initiating a fluoride removal program undertaken by governmental and nongovernmental organizations here in India.
Collapse
Affiliation(s)
- Iftak Hussain
- Applied Photonics and Nano-Photonics Laboratory, Department of Physics, and ‡Department of Civil Engineering, Tezpur University , Assam 784028, India
| | - Kamal Uddin Ahamad
- Applied Photonics and Nano-Photonics Laboratory, Department of Physics, and ‡Department of Civil Engineering, Tezpur University , Assam 784028, India
| | - Pabitra Nath
- Applied Photonics and Nano-Photonics Laboratory, Department of Physics, and ‡Department of Civil Engineering, Tezpur University , Assam 784028, India
| |
Collapse
|
37
|
Rasooly R, Bruck HA, Balsam J, Prickril B, Ossandon M, Rasooly A. Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health. Diagnostics (Basel) 2016; 6:E19. [PMID: 27196933 PMCID: PMC4931414 DOI: 10.3390/diagnostics6020019] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 04/19/2016] [Accepted: 05/06/2016] [Indexed: 12/20/2022] Open
Abstract
Resource-poor countries and regions require effective, low-cost diagnostic devices for accurate identification and diagnosis of health conditions. Optical detection technologies used for many types of biological and clinical analysis can play a significant role in addressing this need, but must be sufficiently affordable and portable for use in global health settings. Most current clinical optical imaging technologies are accurate and sensitive, but also expensive and difficult to adapt for use in these settings. These challenges can be mitigated by taking advantage of affordable consumer electronics mobile devices such as webcams, mobile phones, charge-coupled device (CCD) cameras, lasers, and LEDs. Low-cost, portable multi-wavelength fluorescence plate readers have been developed for many applications including detection of microbial toxins such as C. Botulinum A neurotoxin, Shiga toxin, and S. aureus enterotoxin B (SEB), and flow cytometry has been used to detect very low cell concentrations. However, the relatively low sensitivities of these devices limit their clinical utility. We have developed several approaches to improve their sensitivity presented here for webcam based fluorescence detectors, including (1) image stacking to improve signal-to-noise ratios; (2) lasers to enable fluorescence excitation for flow cytometry; and (3) streak imaging to capture the trajectory of a single cell, enabling imaging sensors with high noise levels to detect rare cell events. These approaches can also help to overcome some of the limitations of other low-cost optical detection technologies such as CCD or phone-based detectors (like high noise levels or low sensitivities), and provide for their use in low-cost medical diagnostics in resource-poor settings.
Collapse
Affiliation(s)
- Reuven Rasooly
- Western Regional Research Center, Agricultural Research Service, U.S. Department of Agriculture, Albany, CA 94706, USA.
| | - Hugh Alan Bruck
- Department of Mechanical Engineering, University of Maryland College Park (UMCP), College Park, MD 20742, USA.
| | - Joshua Balsam
- Division of Chemistry and Toxicology Devices, Office of In Vitro Diagnostics and Radiological Health, FDA, Silver Spring, MD 20993, USA.
| | - Ben Prickril
- National Cancer Institute, Rockville, MD 208503, USA.
| | | | | |
Collapse
|
38
|
Hossain MA, Canning J, Cook K, Jamalipour A. Optical fiber smartphone spectrometer. OPTICS LETTERS 2016; 41:2237-40. [PMID: 27176971 DOI: 10.1364/ol.41.002237] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
An optical fiber-based smartphone spectrometer incorporating an endoscopic fiber bundle is demonstrated. The endoscope allows transmission of the smartphone camera LED light to a sample, removing complications from varying background illumination. The reflected spectra collected from a surface or interface is dispersed onto the camera CMOS using a reflecting diffraction grating. A spectral resolution as low as δλ∼2.0 nm over a bandwidth of Δλ∼250 nm is obtained using a slit width, ωslit=0.7 mm. The instrument has vast potential in a number of industrial applications including agricultural produce analysis. Spectral analysis of apples shows straightforward measurement of the pigments anthocyanins, carotenoid, and chlorophyll, all of which decrease with increasing storage time.
Collapse
|
39
|
Zhang C, Cheng G, Edwards P, Zhou MD, Zheng S, Liu Z. G-Fresnel smartphone spectrometer. LAB ON A CHIP 2016; 16:246-50. [PMID: 26645747 DOI: 10.1039/c5lc01226k] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
We report a smartphone spectrometer with nanometer resolution working in the visible range. A G-Fresnel device with the dual functionality of focusing and dispersion is used to enable miniaturization. Proof of principle application to Bradford assay of protein concentration is also demonstrated.
Collapse
Affiliation(s)
- Chenji Zhang
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, USA.
| | - Gong Cheng
- Department of Biomedical Engineering and Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Perry Edwards
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, USA.
| | - Ming-Da Zhou
- Department of Biomedical Engineering and Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Siyang Zheng
- Department of Biomedical Engineering and Materials Research Institute, The Pennsylvania State University, University Park, PA 16802, USA
| | - Zhiwen Liu
- Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, USA.
| |
Collapse
|
40
|
Petryayeva E, Algar WR. A job for quantum dots: use of a smartphone and 3D-printed accessory for all-in-one excitation and imaging of photoluminescence. Anal Bioanal Chem 2016; 408:2913-25. [DOI: 10.1007/s00216-015-9300-3] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2015] [Revised: 12/17/2015] [Accepted: 12/23/2015] [Indexed: 10/22/2022]
|
41
|
Dutta S, Saikia K, Nath P. Smartphone based LSPR sensing platform for bio-conjugation detection and quantification. RSC Adv 2016. [DOI: 10.1039/c6ra01113f] [Citation(s) in RCA: 80] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Localized surface plasmon resonance based sensing and biosensing has been performed using the camera of a smartphone.
Collapse
Affiliation(s)
- Sibasish Dutta
- Applied Photonics and Nanophotonics Laboratory
- Department of Physics
- Tezpur University
- Assam
- India
| | - Koushik Saikia
- Advanced Functional Materials Laboratory
- Department of Physics
- Tezpur University
- Assam
- India
| | - Pabitra Nath
- Applied Photonics and Nanophotonics Laboratory
- Department of Physics
- Tezpur University
- Assam
- India
| |
Collapse
|
42
|
Hossain MA, Canning J, Cook K, Jamalipour A. Smartphone laser beam spatial profiler. OPTICS LETTERS 2015; 40:5156-5159. [PMID: 26565823 DOI: 10.1364/ol.40.005156] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A simple, low-cost, portable, smartphone-based laser beam profiler for characterizing laser beam profiles is reported. The beam profiler utilizes a phosphor silica glass plate to convert UV light into visible (green) light that can be directly imaged onto an existing smartphone CMOS chip and analyzed using a customized app. 3D printing enables the ready fabrication of the instrument package. The beam's diameter, shape, divergence, beam quality factor, and output power are measured for two UV lasers: a CW 244 nm frequency-doubled Ar ion laser and a pulsed 193 nm ArF exciplex laser. The availability of specialized phosphor converters can extend the instrument from the UV to the near infrared and beyond, and the smartphone platform extends the Internet of Things to map laser beam profiles simultaneously in different locations.
Collapse
|
43
|
Cook K, Canning J, Leon-Saval S, Reid Z, Hossain MA, Comatti JE, Luo Y, Peng GD. Air-structured optical fiber drawn from a 3D-printed preform. OPTICS LETTERS 2015; 40:3966-9. [PMID: 26368688 DOI: 10.1364/ol.40.003966] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
A structured optical fiber is drawn from a 3D-printed structured preform. Preforms containing a single ring of holes around the core are fabricated using filament made from a modified butadiene polymer. More broadly, 3D printers capable of processing soft glasses, silica, and other materials are likely to come on line in the not-so-distant future. 3D printing of optical preforms signals a new milestone in optical fiber manufacture.
Collapse
|