Zheng W, Kou SS, Sheppard CJR, Roy M. Advancing full-field metrology: rapid 3D imaging with geometric phase ferroelectric liquid crystal technology in full-field optical coherence microscopy. BIOMEDICAL OPTICS EXPRESS 2023; 14:3433-3445. [PMID: 37497495 PMCID: PMC10368045 DOI: 10.1364/boe.488806] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 05/30/2023] [Accepted: 05/31/2023] [Indexed: 07/28/2023]
Abstract
Optical coherence microscopy (OCM) is a variant of OCT in which a high-numerical aperture lens is used. Full-field OCM (FF-OCM) is an emerging non-invasive, label-free, interferometric technique for imaging of surface structures or semi-transparent biomedical subjects with micron-scale resolutions. Different approaches to three dimensional full-field optical metrology are reviewed. The usual method for the phase-shifting technique in FF-OCM involves mechanically moving a mirror to change the optical path difference for obtaining en-face OCM images. However, with the use of a broadband source in FF-OCM, the phase shifts of different spectral components are not the same, resulting in the ambiguities in 3D image reconstruction. In this study, we demonstrate, by imaging tissues and cells, a unique geometric phase-shifter based on ferroelectric liquid crystal technology, to realize achromatic phase-shifting for rapid three-dimensional imaging in a FF-OCM system.
Collapse
Affiliation(s)
- Wei Zheng
- Department of Biomedical Engineering, National University of Singapore, Singapore 117576, Singapore
| | - Shan S. Kou
- Chemistry and Physics, La Trobe University, Bundoora, Victoria 3083, Australia
| | - Colin J. R. Sheppard
- Nanoscopy and NIC@IIT, Istituto Italiano di Tecnologia, Via Enrico Melen, 83 Edificio B, 16152 Genova, Italy
- Molecular Horizons, School of Chemistry and Molecular Biosciences, University of Wollongong, Wollongong NSW 2522, Australia
| | - Maitreyee Roy
- School of Optometry and Vision Science, University of New South Wales, NSW 2052, Australia
| |
Collapse
|
2
|
Wang L, Fu R, Xu C, Xu M. Methods and applications of full-field optical coherence tomography: a review. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:JBO-220007VR. [PMID: 35596250 PMCID: PMC9122094 DOI: 10.1117/1.jbo.27.5.050901] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 04/28/2022] [Indexed: 05/24/2023]
Abstract
SIGNIFICANCE Full-field optical coherence tomography (FF-OCT) enables en face views of scattering samples at a given depth with subcellular resolution, similar to biopsy without the need of sample slicing or other complex preparation. This noninvasive, high-resolution, three-dimensional (3D) imaging method has the potential to become a powerful tool in biomedical research, clinical applications, and other microscopic detection. AIM Our review provides an overview of the disruptive innovations and key technologies to further improve FF-OCT performance, promoting FF-OCT technology in biomedical and other application scenarios. APPROACH A comprehensive review of state-of-the-art accomplishments in OCT has been performed. Methods to improve performance of FF-OCT systems are reviewed, including advanced phase-shift approaches for imaging speed improvement, methods of denoising, artifact reduction, and aberration correction for imaging quality optimization, innovations for imaging flux expansion (field-of-view enlargement and imaging-depth-limit extension), new implementations for multimodality systems, and deep learning enhanced FF-OCT for information mining, etc. Finally, we summarize the application status and prospects of FF-OCT in the fields of biomedicine, materials science, security, and identification. RESULTS The most worth-expecting FF-OCT innovations include combining the technique of spatial modulation of optical field and computational optical imaging technology to obtain greater penetration depth, as well as exploiting endogenous contrast for functional imaging, e.g., dynamic FF-OCT, which enables noninvasive visualization of tissue dynamic properties or intracellular motility. Different dynamic imaging algorithms are compared using the same OCT data of the colorectal cancer organoid, which helps to understand the disadvantages and advantages of each. In addition, deep learning enhanced FF-OCT provides more valuable characteristic information, which is of great significance for auxiliary diagnosis and organoid detection. CONCLUSIONS FF-OCT has not been completely exploited and has substantial growth potential. By elaborating the key technologies, performance optimization methods, and application status of FF-OCT, we expect to accelerate the development of FF-OCT in both academic and industry fields. This renewed perspective on FF-OCT may also serve as a road map for future development of invasive 3D super-resolution imaging techniques to solve the problems of microscopic visualization detection.
Collapse
Affiliation(s)
- Ling Wang
- Hangzhou DianZi University, School of Automation, Hangzhou, China
- Key Laboratory of Medical Information and 3D Biological of Zhejiang Province, Hangzhou, China
| | - Rongzhen Fu
- Hangzhou DianZi University, School of Automation, Hangzhou, China
| | - Chen Xu
- Hangzhou DianZi University, School of Automation, Hangzhou, China
| | - Mingen Xu
- Hangzhou DianZi University, School of Automation, Hangzhou, China
- Key Laboratory of Medical Information and 3D Biological of Zhejiang Province, Hangzhou, China
| |
Collapse
|
3
|
Pleskow DK, Zhang L, Turzhitsky V, Coughlan MF, Khan U, Zhang X, Sheil CJ, Glyavina M, Chen L, Shinagare S, Zakharov YN, Vitkin E, Itzkan I, Perelman LT, Qiu L. Coherent confocal light scattering spectroscopic microscopy evaluates cancer progression and aggressiveness in live cells and tissue. ACS PHOTONICS 2021; 8:2050-2059. [PMID: 34485615 PMCID: PMC8411902 DOI: 10.1021/acsphotonics.1c00217] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
The observation of biological structures in live cells beyond the diffraction limit with super-resolution fluorescence microscopy is limited by the ability of fluorescence probes to permeate live cells and the effect of these probes, which are often toxic, on cellular behavior. Here we present a coherent confocal light scattering and absorption spectroscopic microscopy that for the first time enables the use of large numerical aperture optics to characterize structures in live cells down to 10 nm spatial scales, well beyond the diffraction limit. Not only does this new capability allow high resolution microscopy with light scattering contrast, but it can also be used with almost any light scattering spectroscopic application which employs lenses. We demonstrate that the coherent light scattering contrast based technique allows continuous temporal tracking of the transition from non-cancerous to an early cancerous state in live cells, without exogenous markers. We also use the technique to sense differences in the aggressiveness of cancer in live cells and for label free identification of different grades of cancer in resected tumor tissues.
Collapse
Affiliation(s)
- Douglas K. Pleskow
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
- Center for Advanced Endoscopy, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Lei Zhang
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Vladimir Turzhitsky
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Mark F. Coughlan
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Umar Khan
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Xuejun Zhang
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Conor J. Sheil
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Maria Glyavina
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Liming Chen
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Shweta Shinagare
- Department of Pathology, Beth Israel Deaconess Medical Center, Harvard University
| | - Yuri N. Zakharov
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Edward Vitkin
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Irving Itzkan
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| | - Lev T. Perelman
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
- Biological and Biomedical Sciences Program, Harvard University
| | - Le Qiu
- Center for Advanced Biomedical Imaging and Photonics, Division of Gastroenterology, Department of Medicine, Beth Israel Deaconess Medical Center, Harvard University
| |
Collapse
|
4
|
Davis A, Levecq O, Azimani H, Siret D, Dubois A. Simultaneous dual-band line-field confocal optical coherence tomography: application to skin imaging. BIOMEDICAL OPTICS EXPRESS 2019; 10:694-706. [PMID: 30800509 PMCID: PMC6377879 DOI: 10.1364/boe.10.000694] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2018] [Revised: 01/03/2019] [Accepted: 01/03/2019] [Indexed: 05/03/2023]
Abstract
Line-field confocal optical coherence tomography (LC-OCT) operating in two distinct spectral bands centered at 770 nm and 1250 nm is reported, using a single supercontinuum light source and two different line-scan cameras. B-scans are acquired simultaneously in the two bands at 4 frames per second. Greyscale representation and color fusion of the images are performed to either produce a single image with both high resolution (1.3 µm × 1.2 µm, lateral × axial, measured at the surface) in the superficial part of the image and deep penetration, or to highlight the spectroscopic properties of the sample. In vivo images of fair and dark skin are presented with a penetration depth of ∼700 µm.
Collapse
Affiliation(s)
- Arthur Davis
- DAMAE Medical, 28 rue de Turbigo, 75003 Paris, France
- Laboratoire Charles Fabry, Institut d’Optique Graduate School, Université Paris-Saclay, 91127 Palaiseau Cedex, France
| | | | | | - David Siret
- DAMAE Medical, 28 rue de Turbigo, 75003 Paris, France
| | - Arnaud Dubois
- Laboratoire Charles Fabry, Institut d’Optique Graduate School, Université Paris-Saclay, 91127 Palaiseau Cedex, France
| |
Collapse
|
5
|
Ogien J, Dubois A. A compact high-speed full-field optical coherence microscope for high-resolution in vivo skin imaging. JOURNAL OF BIOPHOTONICS 2019; 12:e201800208. [PMID: 30062826 DOI: 10.1002/jbio.201800208] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Accepted: 07/27/2018] [Indexed: 05/06/2023]
Abstract
A compact high-speed full-field optical coherence microscope has been developed for high-resolution in vivo imaging of biological tissues. The interferometer, in the Linnik configuration, has a size of 11 × 11 × 5 cm3 and a weight of 210 g. Full-field illumination with low-coherence light is achieved with a high-brightness broadband light-emitting diode. High-speed full-field detection is achieved by using part of the image sensor of a high-dynamic range CMOS camera. En face tomographic images are acquired at a rate of 50 Hz, with an integration time of 0.9 ms. The image spatial resolution is 0.9 μm × 1.2 μm (axial × transverse), over a field of view of 245 × 245 μm2 . Images of human skin, revealing in-depth cellular-level structures, were obtained in vivo and in real-time without the need for stabilization of the subject. The system can image larger fields, up to 1 × 1 mm2 , but at a reduced depth.
Collapse
Affiliation(s)
- Jonas Ogien
- Laboratoire Charles Fabry, CNRS UMR 8501, Institut d'Optique Graduate School, University of Paris-Saclay, Paris, France
| | - Arnaud Dubois
- Laboratoire Charles Fabry, CNRS UMR 8501, Institut d'Optique Graduate School, University of Paris-Saclay, Paris, France
| |
Collapse
|
6
|
Dubois A. Focus defect and dispersion mismatch in full-field optical coherence microscopy. APPLIED OPTICS 2017; 56:D142-D150. [PMID: 28375370 DOI: 10.1364/ao.56.00d142] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Full-field optical coherence microscopy (FFOCM) is an optical technique, based on low-coherence interference microscopy, for tomographic imaging of semi-transparent samples with micrometer-scale spatial resolution. The differences in refractive index between the sample and the immersion medium of the microscope objectives may degrade the FFOCM image quality because of focus defect and optical dispersion mismatch. These phenomena and their consequences are discussed in this theoretical paper. Experimental methods that have been implemented in FFOCM to minimize the adverse effects of these phenomena are summarized and compared.
Collapse
|
7
|
Thouvenin O, Grieve K, Xiao P, Apelian C, Boccara AC. En face coherence microscopy [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:622-639. [PMID: 28270972 PMCID: PMC5330590 DOI: 10.1364/boe.8.000622] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 12/29/2016] [Accepted: 12/31/2016] [Indexed: 05/13/2023]
Abstract
En face coherence microscopy or flying spot or full field optical coherence tomography or microscopy (FF-OCT/FF-OCM) belongs to the OCT family because the sectioning ability is mostly linked to the source coherence length. In this article we will focus our attention on the advantages and the drawbacks of the following approaches: en face versus B scan tomography in terms of resolution, coherent versus incoherent illumination and influence of aberrations, and scanning versus full field imaging. We then show some examples to illustrate the diverse applications of en face coherent microscopy and show that endogenous or exogenous contrasts can add valuable information to the standard morphological image. To conclude we discuss a few domains that appear promising for future development of en face coherence microscopy.
Collapse
Affiliation(s)
- Olivier Thouvenin
- Institut Langevin ESPCI, PSL Research University, CNRS UMR7587 1rue Jussieu, Paris F75005, France
| | - Kate Grieve
- CHNO des Quinze Vingts/Institut de la Vision, 28 rue de Charenton, Paris F75012, France
| | - Peng Xiao
- Institut Langevin ESPCI, PSL Research University, CNRS UMR7587 1rue Jussieu, Paris F75005, France
| | - Clement Apelian
- Institut Langevin ESPCI, PSL Research University, CNRS UMR7587 1rue Jussieu, Paris F75005, France; LLTech Pépinière Paris Santé Cochin 29 rue du Faubourg Saint Jacques Paris F75014, France
| | - A Claude Boccara
- Institut Langevin ESPCI, PSL Research University, CNRS UMR7587 1rue Jussieu, Paris F75005, France
| |
Collapse
|
8
|
Klein T, Huber R. High-speed OCT light sources and systems [Invited]. BIOMEDICAL OPTICS EXPRESS 2017; 8:828-859. [PMID: 28270988 PMCID: PMC5330584 DOI: 10.1364/boe.8.000828] [Citation(s) in RCA: 106] [Impact Index Per Article: 15.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 01/02/2017] [Accepted: 01/03/2017] [Indexed: 05/18/2023]
Abstract
Imaging speed is one of the most important parameters that define the performance of optical coherence tomography (OCT) systems. During the last two decades, OCT speed has increased by over three orders of magnitude. New developments in wavelength-swept lasers have repeatedly been crucial for this development. In this review, we discuss the historical evolution and current state of the art of high-speed OCT systems, with focus on wavelength swept light sources and swept source OCT systems.
Collapse
Affiliation(s)
- Thomas Klein
- Optores GmbH, Gollierstr. 70, 80339 Munich, Germany
| | - Robert Huber
- Institut für Biomedizinische Optik, Universität zu Lübeck, Peter-Monnik-Weg 4, 23562 Lübeck, Germany
| |
Collapse
|
9
|
Ogien J, Dubois A. High-resolution full-field optical coherence microscopy using a broadband light-emitting diode. OPTICS EXPRESS 2016; 24:9922-31. [PMID: 27137603 DOI: 10.1364/oe.24.009922] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
High-resolution full-field optical coherence microscopy (FF-OCM) is demonstrated using a single broadband light-emitting diode (LED). The characteristics of the LED-illumination FF-OCM system are measured and compared to those obtained using a halogen lamp, the light source of reference in FF-OCM. Both light sources yield identical performance in terms of spatial resolution and detection sensitivity, using the same setup and camera. In particular, an axial resolution of 0.7 μm (in water) is reached. A Xenopus laevis tadpole and ex-vivo human skin have been imaged using both sources, resulting in similar images, showing for the first time that LEDs could favorably replace halogen lamps in high-resolution FF-OCM for biomedical imaging.
Collapse
|
10
|
Gao W. Image contrast reduction mechanism in full-field optical coherence tomography. J Microsc 2016; 261:199-216. [PMID: 26892916 DOI: 10.1111/jmi.12333] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Accepted: 09/15/2015] [Indexed: 11/28/2022]
Abstract
Correct interpretation of image contrast obtained with full-field optical coherence tomography (FFOCT) technique is required for accurate medical diagnosis applications. In this work, first, the characteristics of microscopic structures of tissue that generate the contrast in en-face tomographic image obtained with FFOCT are discussed. Then an overview is given of the parameters that affect image contrast. Finally, the contrast correction factor for correct image interpretation and the contrast limits to practical FFOCT systems are outlined.
Collapse
Affiliation(s)
- Wanrong Gao
- Department of Optical Engineering, Nanjing University of Science and Technology, Nanjing, Jiangsu, P. R. China
| |
Collapse
|
11
|
Federici A, Dubois A. Full-field optical coherence microscopy with optimized ultrahigh spatial resolution. OPTICS LETTERS 2015; 40:5347-50. [PMID: 26565871 DOI: 10.1364/ol.40.005347] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Full-field optical coherence microscopy (FF-OCM) with isotropic spatial resolution of 0.5 μm (in water), at 700 nm center wavelength, is reported. A theoretical study of the FF-OCM axial response is carried out for maximizing the axial resolution of the system, considering the effect of optical dispersion. The lateral resolution is optimized by using water-immersion microscope objectives with a numerical aperture of 1.2. This ultrahigh-resolution FF-OCM system is applied to animal and human skin tissue imaging, revealing ultra-fine in-depth structures at the sub-cellular level.
Collapse
|
12
|
Gao W. Fourier spectrum analysis of full-field optical coherence tomography for tissue imaging. Proc Math Phys Eng Sci 2015. [DOI: 10.1098/rspa.2015.0099] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
We propose a model of the full-field optical coherence tomography (FFOCT) technique for tissue imaging, in which the fractal model of the spatial correlation function of the refractive index of tissue is employed to approximate tissue structure. The results may be helpful for correctly interpreting en face tomographic images obtained with FFOCT.
Collapse
Affiliation(s)
- Wanrong Gao
- Department of Optical Engineering, Nanjing University of Science and Technology, 200 Xao Ling Wei, Nanjing, Jiangsu 210094, People's Republic of China
| |
Collapse
|
13
|
Coron E, Auksorius E, Pieretti A, Mahé MM, Liu L, Steiger C, Bromberg Y, Bouma B, Tearney G, Neunlist M, Goldstein AM. Full-field optical coherence microscopy is a novel technique for imaging enteric ganglia in the gastrointestinal tract. Neurogastroenterol Motil 2012; 24:e611-21. [PMID: 23106847 PMCID: PMC3866795 DOI: 10.1111/nmo.12035] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Noninvasive methods are needed to improve the diagnosis of enteric neuropathies. Full-field optical coherence microscopy (FFOCM) is a novel optical microscopy modality that can acquire 1 μm resolution images of tissue. The objective of this research was to demonstrate FFOCM imaging for the characterization of the enteric nervous system (ENS). METHODS Normal mice and EdnrB(-/-) mice, a model of Hirschsprung's disease (HD), were imaged in three-dimensions ex vivo using FFOCM through the entire thickness and length of the gut. Quantitative analysis of myenteric ganglia was performed on FFOCM images obtained from whole-mount tissues and compared with immunohistochemistry imaged by confocal microscopy. KEY RESULTS Full-field optical coherence microscopy enabled visualization of the full thickness gut wall from serosa to mucosa. Images of the myenteric plexus were successfully acquired from the stomach, duodenum, colon, and rectum. Quantification of ganglionic neuronal counts on FFOCM images revealed strong interobserver agreement and identical values to those obtained by immunofluorescence microscopy. In EdnrB(-/-) mice, FFOCM analysis revealed a significant decrease in ganglia density along the colorectum and a significantly lower density of ganglia in all colorectal segments compared with normal mice. CONCLUSIONS & INFERENCES Full-field optical coherence microscopy enables optical microscopic imaging of the ENS within the bowel wall along the entire intestine. FFOCM is able to differentiate ganglionic from aganglionic colon in a mouse model of HD, and can provide quantitative assessment of ganglionic density. With further refinements that enable bowel wall imaging in vivo, this technology has the potential to revolutionize the characterization of the ENS and the diagnosis of enteric neuropathies.
Collapse
Affiliation(s)
- E Coron
- Wellman Center for Photomedicine, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Zheng JG, Lu D, Chen T, Wang C, Tian N, Zhao F, Huo T, Zhang N, Chen D, Ma W, Sun JL, Xue P. Label-free subcellular 3D live imaging of preimplantation mouse embryos with full-field optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:070503. [PMID: 22894459 DOI: 10.1117/1.jbo.17.7.070503] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Early patterning and polarity is of fundamental interest in preimplantation embryonic development. Label-free subcellular 3D live imaging is very helpful to its related studies. We have developed a novel system of full-field optical coherence tomography (FF-OCT) for noninvasive 3D subcellular live imaging of preimplantation mouse embryos with no need of dye labeling. 3D digitized embryos can be obtained by image processing. Label-free 3D live imaging is demonstrated for the mouse embryos at various typical preimplantation stages with a spatial resolution of 0.7 [micro sign]m and imaging rate of 24 fps. Factors that relate to early patterning and polarity, such as pronuclei in zygote, shapes of zona pellucida, location of second polar body, cleavage planes, and the blastocyst axis, can be quantitatively measured. The angle between the two second cleavage planes is accurately measured to be 87 deg. It is shown that FF-OCT provides a potential breakthrough for early patterning, polarity formation, and many other preimplantation-related studies in mammalian developmental biology.
Collapse
Affiliation(s)
- Jing-gao Zheng
- Tsinghua University, Department of Physics and State Key Lab of Low-Dimensional Quantum Physics, Beijing, China
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
15
|
Unglert CI, Namati E, Warger WC, Liu L, Yoo H, Kang D, Bouma BE, Tearney GJ. Evaluation of optical reflectance techniques for imaging of alveolar structure. JOURNAL OF BIOMEDICAL OPTICS 2012; 17:071303. [PMID: 22894464 DOI: 10.1117/1.jbo.17.7.071303] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Three-dimensional (3-D) visualization of the fine structures within the lung parenchyma could advance our understanding of alveolar physiology and pathophysiology. Current knowledge has been primarily based on histology, but it is a destructive two-dimensional (2-D) technique that is limited by tissue processing artifacts. Micro-CT provides high-resolution three-dimensional (3-D) imaging within a limited sample size, but is not applicable to intact lungs from larger animals or humans. Optical reflectance techniques offer the promise to visualize alveolar regions of the large animal or human lung with sub-cellular resolution in three dimensions. Here, we present the capabilities of three optical reflectance techniques, namely optical frequency domain imaging, spectrally encoded confocal microscopy, and full field optical coherence microscopy, to visualize both gross architecture as well as cellular detail in fixed, phosphate buffered saline-immersed rat lung tissue. Images from all techniques were correlated to each other and then to corresponding histology. Spatial and temporal resolution, imaging depth, and suitability for in vivo probe development were compared to highlight the merits and limitations of each technology for studying respiratory physiology at the alveolar level.
Collapse
Affiliation(s)
- Carolin I Unglert
- Wellman Center for Photomedicine, Harvard Medical School and Massachusetts General Hospital, 40 Parkman Street, RSL 160, Boston, Massachusetts 02114, USA
| | | | | | | | | | | | | | | |
Collapse
|
16
|
Xiao J, Wang B, Lu G, Zhu Z, Huang Y. Imaging of oocyte development using ultrahigh-resolution full-field optical coherence tomography. APPLIED OPTICS 2012; 51:3650-3654. [PMID: 22695605 DOI: 10.1364/ao.51.003650] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2011] [Accepted: 12/06/2011] [Indexed: 06/01/2023]
Abstract
In this paper, a white-light full-field optical coherence tomography is developed to provide three-dimensional imaging of the development of a mouse embryo with ultrahigh-resolution. Spatial resolution of 1.8 μm×1.12 μm (transverse×axial) is achieved owing to the extremely short coherence length of the light source and optimized compensation of dispersion mismatch. A shot-noise limited detection sensitivity of 80 dB is obtained at an acquisition time of 5 seconds per image. To enable in vivo imaging of the mouse embryo development, a homemade incubator is applied to provide appropriate CO2 concentration, temperature, and humidity. An electronic light shutter is used to control the light source in order to avoid unnecessary exposure to the embryo development when the sample is not being scanned. To demonstrate our method, in vivo time series two-dimensional images of the in vitro fertilization process of mouse oocytes at the germinal vesicles stage are presented.
Collapse
Affiliation(s)
- Jiaying Xiao
- School of Geosciences and Info-Physics Engineering, Central South University, Changsha 410083, China
| | | | | | | | | |
Collapse
|
17
|
Chen Y, Huang SW, Zhou C, Potsaid B, Fujimoto JG. Improved Detection Sensitivity of Line-Scanning Optical Coherence Microscopy. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2012; 18:1094-1099. [PMID: 22685379 PMCID: PMC3369695 DOI: 10.1109/jstqe.2011.2161758] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Optical coherence microscopy (OCM) is a promising technology for high-resolution cellular-level imaging in human tissues. Line-scanning OCM is a new form of OCM that utilizes line-field illumination for parallel detection. In this study, we demonstrate improved detection sensitivity by using an achromatic design for line-field generation. This system operates at 830-nm wavelength with 82-nm bandwidth. The measured axial resolution is 3.9 μm in air (corresponding to ~2.9 μm in tissue), and the transverse resolutions are 2.1 μm along the line-field illumination direction and 1.7 μm perpendicular to line illumination direction. The measured sensitivity is 98 dB with 25 line averages, resulting in an imaging speed of ~2 frames/s (516 lines/s). Real-time, cellular-level imaging of scattering tissues is demonstrated using human-colon specimens.
Collapse
Affiliation(s)
- Yu Chen
- Fischell Department of Bioengineering, University of Maryland, College Park, MD 20742 USA ( )
| | | | | | | | | |
Collapse
|
18
|
Dubois A. Spectroscopic polarization-sensitive full-field optical coherence tomography. OPTICS EXPRESS 2012; 20:9962-77. [PMID: 22535089 DOI: 10.1364/oe.20.009962] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Full-field optical coherence tomography (FF-OCT) is a recent optical imaging technology based on low-coherence interference microscopy for imaging of semi-transparent samples with ~1 µm spatial resolution. FF-OCT produces en-face tomographic images obtained by arithmetic combination of interferometric images acquired by an array camera. In this paper, we demonstrate a unique multimodal FF-OCT system, capable of measuring simultaneously the intensity, the power spectrum and the phase-retardation of light backscattered by the sample being imaged. Compared to conventional FF-OCT, this multimodal system provides enhanced imaging contrasts at the price of a moderate increase in experimental complexity and cost.
Collapse
Affiliation(s)
- Arnaud Dubois
- Laboratoire Charles Fabry, Institut d’Optique, CNRS UMR 8501, Univ Paris-Sud, 2 avenue Augustin Fresnel, 91127 Palaiseau, France.
| |
Collapse
|
19
|
Full-Field and Single-Shot Full-Field Optical Coherence Tomography: A Novel Technique for Biomedical Imaging Applications. ACTA ACUST UNITED AC 2012. [DOI: 10.1155/2012/435408] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Since its introduction, optical coherence tomography (OCT) technology has advanced dramatically in various field of both clinical and fundamental research. Full-field and Single-shot full-field OCT (FF-OCT and SS-FF-OCT) are alternative OCT concepts, which aims to improve the image acquisition speed and to simplify the optical setup of conventional point-scan OCT by realizing direct line field or full-field sample imaging onto an array or line detector such as CCD or CMOS camera. FF-OCT and SS-FF-OCT are based on bulk optics Linnik-type Michelson interferometer with relatively high numerical aperture (NA) microscopic objectives. This paper will give you an overview of the principle of various types of FF-OCT and SS-FF-OCT techniques and its associated system design concept and image reconstruction algorithms.
Collapse
|
20
|
Auksorius E, Bromberg Y, Motiejūnaitė R, Pieretti A, Liu L, Coron E, Aranda J, Goldstein AM, Bouma BE, Kazlauskas A, Tearney GJ. Dual-modality fluorescence and full-field optical coherence microscopy for biomedical imaging applications. BIOMEDICAL OPTICS EXPRESS 2012; 3:661-6. [PMID: 22435110 PMCID: PMC3296550 DOI: 10.1364/boe.3.000661] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2012] [Revised: 02/17/2012] [Accepted: 02/24/2012] [Indexed: 05/21/2023]
Abstract
Full-field optical coherence microscopy (FFOCM) is a high-resolution interferometric technique that is particularly attractive for biomedical imaging. Here we show that combining it with structured illumination fluorescence microscopy on one platform can increase its versatility since it enables co-localized registration of optically sectioned reflectance and fluorescence images. To demonstrate the potential of this dual modality, a fixed and labeled mouse retina was imaged. Results showed that both techniques can provide complementary information and therefore the system could potentially be useful for biomedical imaging applications.
Collapse
Affiliation(s)
- Egidijus Auksorius
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Yaron Bromberg
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Rūta Motiejūnaitė
- Harvard Medical School and Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, 20 Staniford Street, Boston, MA 02114, USA
- Department of Biochemistry and Biophysics, Vilnius University, Vilnius, Lithuania
| | - Alberto Pieretti
- Department of Pediatric Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA 02114, USA
| | - Linbo Liu
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Emmanuel Coron
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| | - Jorge Aranda
- Harvard Medical School and Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, 20 Staniford Street, Boston, MA 02114, USA
| | - Allan M. Goldstein
- Department of Pediatric Surgery, Harvard Medical School and Massachusetts General Hospital, Boston, MA 02114, USA
| | - Brett E. Bouma
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
| | - Andrius Kazlauskas
- Harvard Medical School and Schepens Eye Research Institute, Massachusetts Eye and Ear Infirmary, 20 Staniford Street, Boston, MA 02114, USA
| | - Guillermo J. Tearney
- Harvard Medical School and Wellman Center for Photomedicine, Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
- Harvard-MIT Division of Health Sciences and Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA
- Department of Pathology, Harvard Medical School and Massachusetts General Hospital, 55 Fruit Street, Boston, MA 02114, USA
| |
Collapse
|
21
|
Anna T, Srivastava V, Mehta DS, Shakher C. High-resolution full-field optical coherence microscopy using a Mirau interferometer for the quantitative imaging of biological cells. APPLIED OPTICS 2011; 50:6343-6351. [PMID: 22192985 DOI: 10.1364/ao.50.006343] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
In this paper quantitative imaging of biological cells using high-resolution full-field optical coherence microscopy (FF-OCM) is reported. The FF-OCM was realized using a swept-source system, a Mirau interferometer, and a CCD camera (a two-dimensional detection unit). A Mirau-interferometric objective lens was used to generate the interferometric signal. The signal was analyzed by a Fourier analysis technique. Optically sectioned amplitude images and a quantitative phase map of biological cells such as onion skin and red blood cells (RBCs) are demonstrated. Further, the refractive index profile of the RBCs is also presented. For the 50× Mirau objective, the experimentally achieved axial and transverse resolution of the present system are 3.8 and 1.2 μm, respectively. The CCD provides parallel detection and measures enface images without X, Y, Z mechanical scanning.
Collapse
Affiliation(s)
- Tulsi Anna
- Laser Applications and Holography Laboratory, Instrument Design Development Centre, Indian Institute of Technology Delhi, Hauz Khas, New Delhi-110016, India
| | | | | | | |
Collapse
|
22
|
Choi WJ, Jung SP, Shin JG, Yang D, Lee BH. Characterization of wet pad surface in chemical mechanical polishing (CMP) process with full-field optical coherence tomography (FF-OCT). OPTICS EXPRESS 2011; 19:13343-13350. [PMID: 21747489 DOI: 10.1364/oe.19.013343] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Chemical mechanical polishing (CMP) is a key process for global planarization of silicon wafers for semiconductors and AlTiC wafers for magnetic heads. Removal rate of wafer material is directly dependent on the surface roughness of a CMP pad, thus the structure of the pad surface has been evaluated with variable techniques. However, under in situ CMP process, the measurements have been severely limited due to the existence of polishing fluids including the slurry on the pad surface. In here, we newly introduce ultra-high resolution full-field optical coherence tomography (FF-OCT) to investigate the surface of wet pads. With FF-OCT, the wet pad surface could be quantitatively characterized in terms of the polishing pad lifetime, and also be three-dimensionally visualized. We found that reasonable polishing span could be evaluated from the surface roughness measurement and the groove depth measurement made by FF-OCT.
Collapse
Affiliation(s)
- Woo June Choi
- School of Information and Communications, Gwangju Institute of Science and Technology, Buk-Gu, Gwangju, South Korea
| | | | | | | | | |
Collapse
|
23
|
Safrani A, Abdulhalim I. Spatial coherence effect on layer thickness determination in narrowband full-field optical coherence tomography. APPLIED OPTICS 2011; 50:3021-7. [PMID: 21691370 DOI: 10.1364/ao.50.003021] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Longitudinal spatial coherence (LSC) is determined by the spatial frequency content of an optical beam. The use of lenses with a high numerical aperture (NA) in full-field optical coherence tomography and a narrowband light source makes the LSC length much shorter than the temporal coherence length, hence suggesting that high-resolution 3D images of biological and multilayered samples can be obtained based on the low LSC. A simplified model is derived, supported by experimental results, which describes the expected interference output signal of multilayered samples when high-NA lenses are used together with a narrowband light source. An expression for the correction factor for the layer thickness determination is found valid for high-NA objectives. Additionally, the method was applied to a strongly scattering layer, demonstrating the potential of this method for high-resolution imaging of scattering media.
Collapse
Affiliation(s)
- Avner Safrani
- Department of Electro Optic Engineering and the Ilse Katz Institute for Nanoscale Science and Technology, Ben Gurion University of the Negev, Beer Sheva 84105, Israel.
| | | |
Collapse
|
24
|
Verrier I, Veillas C, Lépine T, Nguyen F, Thuret G, Gain P. Interfaces detection after corneal refractive surgery by low coherence optical interferometry. BIOMEDICAL OPTICS EXPRESS 2010; 1:1460-1471. [PMID: 21258562 PMCID: PMC3018127 DOI: 10.1364/boe.1.001460] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/21/2010] [Revised: 11/10/2010] [Accepted: 11/12/2010] [Indexed: 05/30/2023]
Abstract
The detection of refractive corneal surgery by LASIK, during the storage of corneas in Eye Banks will become a challenge when the numerous operated patients will arrive at the age of cornea donation. The subtle changes of corneal structure and refraction are highly suspected to negatively influence clinical results in recipients of such corneas. In order to detect LASIK cornea interfaces we developed a low coherence interferometry technique using a broadband continuum source. Real time signal recording, without moving any optical elements and without need of a Fourier Transform operation, combined with good measurement resolution is the main asset of this interferometer. The associated numerical processing is based on a method initially used in astronomy and offers an optimal correlation signal without the necessity to image the whole cornea that is time consuming. The detection of corneal interfaces - both outer and inner surface and the buried interface corresponding to the surgical wound - is then achieved directly by the innovative combination of interferometry and this original numerical process.
Collapse
Affiliation(s)
- I. Verrier
- Université de Lyon, F-42023, Saint-Etienne, France
- CNRS, UMR 5516, Laboratoire Hubert Curien, F-42000 Saint-Etienne, France
| | - C. Veillas
- Université de Lyon, F-42023, Saint-Etienne, France
- CNRS, UMR 5516, Laboratoire Hubert Curien, F-42000 Saint-Etienne, France
| | - T. Lépine
- Université de Lyon, F-42023, Saint-Etienne, France
- CNRS, UMR 5516, Laboratoire Hubert Curien, F-42000 Saint-Etienne, France
- Institut d’Optique Rhône-Alpes, 18, rue Benoît LAURAS 42000 Saint-Etienne, France
| | - F. Nguyen
- Université de Lyon, F-42023, Saint-Etienne, France
- Laboratoire Biologie, Ingénerie et Imagerie de la Greffe de Cornée, JE2521, IFR143,
Université Saint-Etienne, Jean Monnet, F-42000, Saint-Etienne, France
| | - G. Thuret
- Université de Lyon, F-42023, Saint-Etienne, France
- Laboratoire Biologie, Ingénerie et Imagerie de la Greffe de Cornée, JE2521, IFR143,
Université Saint-Etienne, Jean Monnet, F-42000, Saint-Etienne, France
| | - P. Gain
- Université de Lyon, F-42023, Saint-Etienne, France
- Laboratoire Biologie, Ingénerie et Imagerie de la Greffe de Cornée, JE2521, IFR143,
Université Saint-Etienne, Jean Monnet, F-42000, Saint-Etienne, France
| |
Collapse
|
25
|
Wojtkowski M. High-speed optical coherence tomography: basics and applications. APPLIED OPTICS 2010; 49:D30-61. [PMID: 20517358 DOI: 10.1364/ao.49.000d30] [Citation(s) in RCA: 141] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
In the past decade we have observed a rapid development of ultrahigh-speed optical coherence tomography (OCT) instruments, which currently enable performing cross-sectional in vivo imaging of biological samples with speeds of more than 100,000 A-scans/s. This progress in OCT technology has been achieved by the development of Fourier-domain detection techniques. Introduction of high-speed imaging capabilities lifts the primary limitation of early OCT technology by giving access to in vivo three-dimensional volumetric reconstructions on large scales within reasonable time constraints. As result, novel tools can be created that add new perspective for existing OCT applications and open new fields of research in biomedical imaging. Especially promising is the capability of performing functional imaging, which shows a potential to enable the differentiation of tissue pathologies via metabolic properties or functional responses. In this contribution the fundamental limitations and advantages of time-domain and Fourier-domain interferometric detection methods are discussed. Additionally the progress of high-speed OCT instruments and their impact on imaging applications is reviewed. Finally new perspectives on functional imaging with the use of state-of-the-art high-speed OCT technology are demonstrated.
Collapse
Affiliation(s)
- Maciej Wojtkowski
- Institute of Physics, Nicolaus Copernicus University, ul. Grudziadzka 5, 87-100, Torun, Poland.
| |
Collapse
|
26
|
Zhou C, Wang Y, Aguirre AD, Tsai TH, Cohen DW, Connolly JL, Fujimoto JG. Ex vivo imaging of human thyroid pathology using integrated optical coherence tomography and optical coherence microscopy. JOURNAL OF BIOMEDICAL OPTICS 2010; 15:016001. [PMID: 20210448 PMCID: PMC2844129 DOI: 10.1117/1.3306696] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/07/2009] [Revised: 11/04/2009] [Accepted: 11/05/2009] [Indexed: 05/28/2023]
Abstract
We evaluate the feasibility of optical coherence tomography (OCT) and optical coherence microscopy (OCM) for imaging of benign and malignant thyroid lesions ex vivo using intrinsic optical contrast. 34 thyroid gland specimens are imaged from 17 patients, covering a spectrum of pathology ranging from normal thyroid to benign disease/neoplasms (multinodular colloid goiter, Hashimoto's thyroiditis, and follicular adenoma) and malignant thyroid tumors (papillary carcinoma and medullary carcinoma). Imaging is performed using an integrated OCT and OCM system, with <4 microm axial resolution (OCT and OCM), and 14 microm (OCT) and <2 microm (OCM) transverse resolution. The system allows seamless switching between low and high magnifications in a way similar to traditional microscopy. Good correspondence is observed between optical images and histological sections. Characteristic features that suggest malignant lesions, such as complex papillary architecture, microfollicules, psammomatous calcifications, or replacement of normal follicular architecture with sheets/nests of tumor cells, can be identified from OCT and OCM images and are clearly differentiable from normal or benign thyroid tissues. With further development of needle-based imaging probes, OCT and OCM could be promising techniques to use for the screening of thyroid nodules and to improve the diagnostic specificity of fine needle aspiration evaluation.
Collapse
Affiliation(s)
- Chao Zhou
- Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, Cambridge, Massachusetts 02139, USA
| | | | | | | | | | | | | |
Collapse
|
27
|
Muller MS, Fraser JM. Contrast improvement in Fourier-domain optical coherence tomography through time gating. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2009; 26:969-976. [PMID: 19340272 DOI: 10.1364/josaa.26.000969] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Time-gated (TG) Fourier-domain optical coherence tomography (FDOCT) exploits interferometric imaging with incoherent gating to filter out unwanted backreflections and improve contrast. The system uses sum-frequency generation with a variable length optical pulse as a "time gate" to restrict the depth field of view of backscattered light to 84-176 microm (-20 dB points). The imaging bandwidth is upconverted from the IR (1280 nm) to visible (504 nm), which allows the use of sensitive silicon-based detection technology, prior to standard FDOCT processing. The TG system achieves a maximum sensitivity of 88 dB, and a contrast enhancement of 29 dB is shown over a standard IR FDOCT system. Imaging of a highly scattering medium (onion skin) is also demonstrated.
Collapse
Affiliation(s)
- Matthew S Muller
- Department of Physics, Engineering Physics & Astronomy, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | | |
Collapse
|
28
|
Sacchet D, Moreau J, Georges P, Dubois A. Simultaneous dual-band ultra-high resolution full-field optical coherence tomography. OPTICS EXPRESS 2008; 16:19434-46. [PMID: 19030031 DOI: 10.1364/oe.16.019434] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Ultrahigh-resolution full-field optical coherence tomography (FF-OCT) is demonstrated in the 800 nm and 1200 nm wavelength regions simultaneously using a Silicon-based (Si) CCD camera and an Indium Gallium Arsenide (InGaAs) camera as area detectors and a halogen lamp as illumination source. The FF-OCT setup is optimized to support the two broad spectral bands in parallel, achieving a detection sensitivity of approximately 90 dB and a micrometer-scale resolution in the three directions. Images of ex vivo biological tissues are presented (rabbit trachea and Xenopus laevis tadpole) with an increase in penetration depth at 1200 nm. A color image representation is applied to fuse both images and enhance spectroscopic property visualization.
Collapse
Affiliation(s)
- Delphine Sacchet
- Laboratoire Charles Fabry de l'Institut d'Optique, CNRS UMR 8501, Université Paris-Sud, Campus Polytechnique, RD128, 91127 Palaiseau Cedex, France.
| | | | | | | |
Collapse
|
29
|
Preliminary evaluation of noninvasive microscopic imaging techniques for the study of vocal fold development. J Voice 2008; 23:269-76. [PMID: 18346865 DOI: 10.1016/j.jvoice.2007.10.003] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2007] [Accepted: 10/01/2007] [Indexed: 11/20/2022]
Abstract
Understanding pediatric voice development and laryngeal pathology is predicated on a detailed knowledge of the microanatomy of the layered structure of the vocal fold. Our current knowledge of this microanatomy and its temporal evolution is limited by the lack of pediatric specimen availability. By providing the capability to image pediatric vocal folds in vivo, a noninvasive microscopy technique could greatly expand the existing database of pediatric laryngeal microanatomy and could furthermore make longitudinal studies possible. A variety of natural-contrast optical imaging technologies, including optical frequency domain imaging (OFDI), full-field optical coherence microscopy (FF-OCM), and spectrally encoded confocal microscopy (SECM) have been recently developed for noninvasive diagnosis in adult patients. In this paper, we demonstrate the potential of these three techniques for laryngeal investigation by obtaining images of excised porcine vocal fold samples. In our study, OFDI allowed visualization of the vocal fold architecture deep within the tissue, from the superficial mucosa to the vocalis muscle. The micron-level resolution of SECM allowed investigation of cells and extracellular matrix fibrils from the superficial mucosa to the intermediate layer of the lamina propria (LP) (350 microm penetration depth). The large field of view (up to 700 microm), penetration depth (up to 500 microm), and resolution (2x2x1microm [XxYxZ]) of FF-OCM enabled comprehensive three-dimensional evaluation of the layered structure of the LP. Our results suggest that these techniques provide important and complementary cellular and structural information, which may be useful for investigating pediatric vocal fold maturation in vivo.
Collapse
|
30
|
Watanabe Y, Sato M. Quasi-single shot axial-lateral parallel time domain optical coherence tomography with Hilbert transformation. OPTICS EXPRESS 2008; 16:524-534. [PMID: 18542127 DOI: 10.1364/oe.16.000524] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We developed axial-lateral parallel time-domain optical coherence tomography (ALP TD-OCT) from a single interference image. A two-dimensional camera can produce a depth-resolved interference image using diffracted light as the reference beam and a linear illumination beam without any mechanical scan. An OCT image of biological tissues with sufficient sensitivity requires extraction of interference signals by subtracting the DC image, which contains the intensity of noninterference light and the electrical noise of the camera, from a single interference image and subsequent application of the Hilbert transformation for each axial direction. We measured 300 interference images of a moving human finger in vivo using an indium gallium arsenide (InGaAs) camera (320 x 250 pixels) operating at 60 frames per second and then obtained OCT images with an imaging range of 5.0 x 1.7-mm(2) (lateral x axial) using a DC image based on averaged interference images. The system sensitivity was 90.5 dB with a 1.05-ms exposure. As the OCT image depends on the interference signals in a single interference image, the OCT signals were stable compared with OCT images based on the phase-shift method.
Collapse
Affiliation(s)
- Yuuki Watanabe
- Graduate School of Science and Engineering, Yamagata University, 4-3-16 Johnan, Yonezawa, Yamagata, 992-8510, Japan.
| | | |
Collapse
|
31
|
Adler DC, Stenger J, Gorczynska I, Lie H, Hensick T, Spronk R, Wolohojian S, Khandekar N, Jiang JY, Barry S, Cable AE, Huber R, Fujimoto JG. Comparison of three-dimensional optical coherence tomography and high resolution photography for art conservation studies. OPTICS EXPRESS 2007; 15:15972-86. [PMID: 19550884 DOI: 10.1364/oe.15.015972] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Gold punchwork and underdrawing in Renaissance panel paintings are analyzed using both three-dimensional swept source / Fourier domain optical coherence tomography (3D-OCT) and high resolution digital photography. 3D-OCT can generate en face images with micrometer-scale resolutions at arbitrary sectioning depths, rejecting out-of-plane light by coherence gating. Therefore 3D-OCT is well suited for analyzing artwork where a surface layer obscures details of interest. 3D-OCT also enables cross-sectional imaging and quantitative measurement of 3D features such as punch depth, which is beneficial for analyzing the tools and techniques used to create works of art. High volumetric imaging speeds are enabled by the use of a Fourier domain mode locked (FDML) laser as the 3D-OCT light source. High resolution infrared (IR) digital photography is shown to be particularly useful for the analysis of underdrawing, where the materials used for the underdrawing and paint layers have significantly different IR absrption properties. In general, 3D-OCT provides a more flexible and comprehensive analysis of artwork than high resolution photography, but also requires more complex instrumentation and data analysis.
Collapse
|
32
|
Akiba M, Chan KP. In vivo video-rate cellular-level full-field optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2007; 12:064024. [PMID: 18163840 DOI: 10.1117/1.2822159] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Full-field optical coherence tomography (FF-OCT) capable of in vivo cellular-level imaging is demonstrated for nonscanning horizontal cross-sectional imaging. The system is based on a white light interference microscope illuminated by a thermal light source. A dual-channel two-dimensional (2-D) detection technique incorporated with a pair of CCD cameras has been developed, where a pair of interferometric images with phase difference of pi/2 are simultaneously captured using an achromatic phase shifter. By acquiring an additional pair of images with a conventional phase shift method, a horizontal cross section is derived from every two consecutive CCD frames, enabling OCT imaging at the video rate. Using an ultrabroad bandwidth illumination incorporated with relatively high NA (0.8 NA) water immersion objectives, an axial resolution of 0.8 microm and a transverse resolution of 0.7 microm are experimentally confirmed. A field of view of 215 microm x 215 microm is covered by the 500 x 500 pixel CCD cameras. We demonstrate, for what is believed to be the first time, in vivo cellular-level blood flow imaging of a Xenopus laevis tadpole by FF-OCT.
Collapse
Affiliation(s)
- Masahiro Akiba
- Yamagata Promotional Organization for Industrial Technology, 2-2-1, Matsuei, Yamagata 990-2473, Japan.
| | | |
Collapse
|
33
|
Chen Y, Huang SW, Aguirre AD, Fujimoto JG. High-resolution line-scanning optical coherence microscopy. OPTICS LETTERS 2007; 32:1971-3. [PMID: 17632613 DOI: 10.1364/ol.32.001971] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
An optical coherence microscopy system based on line illumination and detection is demonstrated. The system uses a Linnik-type interferometer illuminated by a broadband Ti:sapphire laser and detected by a high-speed, line-scan CCD camera. This approach is less sensitive to incoherent scattering and sample motion than full-field imaging. Spatial resolutions of approximately 2 microm x approximately 3 microm(transverse x axial) are achieved. The sensitivity of the system is 93 dB with averaging over 30 line scans. En face real time, cellular-level imaging of biological tissues is demonstrated at approximately 2 frames/s.
Collapse
Affiliation(s)
- Yu Chen
- Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, USA.
| | | | | | | |
Collapse
|
34
|
Akiba M, Maeda N, Yumikake K, Soma T, Nishida K, Tano Y, Chan KP. Ultrahigh-resolution imaging of human donor cornea using full-field optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2007; 12:041202. [PMID: 17867791 DOI: 10.1117/1.2764461] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
A feasibility study of ultrahigh-resolution full-field optical coherence tomography (FF-OCT) for a subcellular-level imaging of human donor corneas is presented. The FF-OCT system employed in this experiment is based on a white light interference microscope, where the sample is illuminated by a thermal light source and a horizontal cross-sectional (en face) image is detected using a charge coupled device (CCD) camera. A conventional four-frame phase-shift detection technique is employed to extract the interferometric image from the CCD output. A 95-nm-broadband full-field illumination yields an axial resolution of 2.0 microm, and the system covers an area of 850 microm x 850 microm with a transverse resolution of 2.4 microm using a 0.3-NA microscope objective and a CCD camera with 512 x 512 pixels. Starting a measurement from the epithelial to the endothelial side, a series of en face images was obtained. From detected en face images, the epithelial cells, Bowman's layer, stromal keratocyte, nerve fiber, Descemet's membrane, and endothelial cell were clearly observed. Keratocyte cytoplasm, its nuclei, and its processes were also separately detected. Two-dimensional interconnectivity of the keratocytes is visualized, and the keratocytes existing between collagen lamellaes are separately extracted by exploiting a high axial resolution ability of FF-OCT.
Collapse
Affiliation(s)
- Masahiro Akiba
- Yamagata Promotional Organization for Industrial Technology, Yamagata, Japan.
| | | | | | | | | | | | | |
Collapse
|
35
|
Abdulhalim I. Competence between spatial and temporal coherence in full field optical coherence tomography and interference microscopy. ACTA ACUST UNITED AC 2006. [DOI: 10.1088/1464-4258/8/11/004] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
36
|
Oh W, Bouma B, Iftimia N, Yelin R, Tearney G. Spectrally-modulated full-field optical coherence microscopy for ultrahigh-resolution endoscopic imaging. OPTICS EXPRESS 2006; 14:8675-84. [PMID: 19529248 PMCID: PMC2785552 DOI: 10.1364/oe.14.008675] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Full-field optical coherence microscopy (FFOCM) utilizes coherence gating to obtain high-resolution optical sections in thick tissues. FFOCM is an attractive technology for endoscopic microscopy at the cellular level since it does not require a high NA objective lens or beam scanning and is therefore particularly amenable to miniaturization. In this manuscript, we present a novel scheme for conducting FFOCM that utilizes spectrally modulated, spatially incoherent illumination and a static Linnik interferometer. This approach is advantageous for endoscopic microscopy since it allows FFOCM to be conducted through a single multimode fiber optic imaging bundle and does not require moving parts in the endoscope probe. Images acquired from biological samples in free space demonstrate that this new method provides the same detailed microscopic structure as that of conventional FFOCM. High-resolution images were also obtained through a multimode fiber bundle, further supporting the potential of this method for endoscopic microscopy.