1
|
Tower SS, Gessner BD, Cho CS, Bridges RL. The association of cobalturia with cobaltism symptoms a prospective blinded study of 229 post-arthroplasty patients. PLoS One 2023; 18:e0295203. [PMID: 38127904 PMCID: PMC10734948 DOI: 10.1371/journal.pone.0295203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Accepted: 11/15/2023] [Indexed: 12/23/2023] Open
Abstract
INTRODUCTION Cobalt is a mitochondrial toxin, clinical cobaltism manifests with constitutional, neurologic, and cardiovascular symptomatology. Cobalt's severe toxidrome is known through case reports from extreme wear or corrosion of cobalt-chromium arthroplasty components. However, the spectrum and epidemiology of orthopedic-implant cobaltism and its relationship to duration and degree of cobalt exposure are not well defined. METHODS The relationship of urine-cobalt concentration and duration of exposure to cobalt-chromium joint implants and cobaltism symptomatology were prospectively studied in 229 patients. Subjects received a Cobaltism-Symptom-Inventory-Score (CSIS) based on a protocolized interview and examination followed by a spot urine-cobalt measurement. RESULTS 129 (56%) subjects were cobalturic (urine-cobalt ≥1.0 ppb). 122 (53%) subjects had a CSIS of >2, this status significantly associates with cobalturia. Median [IQR] urine-cobalt in the subjects with a CSIS >2 was 4.1[1.1-17.0] ppb compared to 0.5[0.5-1.4] ppb in subjects with CSIS ≤ 2. Cobalturia has a sensitivity of 0.69, a specificity of 0.77, and a positive predictive value of 0.74 for a CSIS of >2. The product of years-exposed to a cobalt-chromium implant and urine-cobalt by quartiles significantly positively associates with the Cobaltism-Symptom-Inventory-Score. CONCLUSION A urine-cobalt of ≥1 ppb likely indicates adverse systemic exposure to orthopedic-implant generated cobalt. Cobaltism severity as quantified by the CSIS significantly correlates with the product of spot urine-cobalt concentration and years-exposed to a cobalt-chromium orthopedic-implant indicating a dose-response relationship. Medical provider and public awareness of orthopedic-implant cobaltism is vital because tens-of-millions are at-risk and early cobaltism is reversible. Further use of cobalt-chromium orthopedic-implants should be questioned given cobaltism becomes clinically apparent at a spot urine-cobalt of 1 ppb or greater. Monitoring of patients with high-risk cobalt-chromium orthopedic-implants appears to be indicated.
Collapse
Affiliation(s)
- Stephen S. Tower
- University of Alaska, Medical School, Anchorage, Alaska, United States of America
| | | | - Christina S. Cho
- University of Alaska, Medical School, Anchorage, Alaska, United States of America
| | - Robert L. Bridges
- Aegis Imaging Consultants, Girdwood, Alaska, United States of America
| |
Collapse
|
2
|
Potter BK. From Bench to Bedside: Detangling Safety and Efficacy for Products and Interventions That May Be Neither. Clin Orthop Relat Res 2022; 480:1455-1457. [PMID: 35767809 PMCID: PMC9278903 DOI: 10.1097/corr.0000000000002292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 06/03/2022] [Indexed: 01/31/2023]
Affiliation(s)
- Benjamin K Potter
- Norman M. Rich Professor & Chair, Uniformed Services University-Walter Reed Department of Surgery, Bethesda, MD, USA
| |
Collapse
|
3
|
Release of metal elements from the Essure implant: A prospective cohort study. Eur J Obstet Gynecol Reprod Biol 2022; 273:20-25. [PMID: 35447464 DOI: 10.1016/j.ejogrb.2022.04.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 04/05/2022] [Accepted: 04/12/2022] [Indexed: 11/22/2022]
Abstract
OBJECTIVE(S) The causal mechanistic relationships between Essure® and adverse effects are unclear, but corrosion in the in-vivo environment with release of metal ions may be suspected. Here we evaluated the concentrations of nickel (Ni), chromium (Cr) and tin (Sn) in the peritoneal fluid (PF) and in the fallopian tube (FT) during laparoscopic Essure® removal compared to a control group. STUDY DESIGN Ni, Cr and Sn concentrations were determined in the PF and FT from two groups(group A: symptomatic patients with Essure®) vs group B (control group without Essure®) by Inductively Coupled Plasma Mass Spectrometry analysis. Correlation between metal elements concentrations and reported pre-operative symptoms was also investigated. RESULTS There were 131 patients in group A vs 92 control patients in group B. The concentrations of Cr and Ni in PF between both groups were significantly different (p < 0.0001) while there was no statistical difference for Sn (p = 0.58). There was also a significantly higher concentration in the FT for the 3 metal elements in group A than in group B (p < 0.0001). There were differential dynamics of the levels of metal elements based on the length of time between the placement and removal of Essure®. CONCLUSIONS There was a chronic exposure to metal elements in symptomatic patients with Essure® raising the question of the relationship between adverse effects and these potential toxic metals.
Collapse
|
4
|
Deere K, Matharu GS, Ben-Shlomo Y, Wilkinson JM, Blom AW, Sayers A, Whitehouse MR. The risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders with cobalt-chrome-containing total hip arthroplasty implants : an analysis of the National Joint Registry. Bone Joint J 2022; 104-B:359-367. [PMID: 35227088 DOI: 10.1302/0301-620x.104b3.bjj-2021-0397.r1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
AIMS A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. CONCLUSION CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant adverse systemic effects. Cite this article: Bone Joint J 2022;104-B(3):359-367.
Collapse
Affiliation(s)
- Kevin Deere
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Gulraj S Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Yoav Ben-Shlomo
- Department of Population Health Sciences, University of Bristol, Bristol, UK
| | - J Mark Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| | - Ashley W Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| | - Adrian Sayers
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Michael R Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| |
Collapse
|
5
|
Deere K, Matharu GS, Ben-Shlomo Y, Wilkinson JM, Blom AW, Sayers A, Whitehouse MR. The risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders with cobalt-chrome-containing total hip arthroplasty implants : an analysis of the National Joint Registry. Bone Joint J 2022:1-9. [PMID: 35018786 DOI: 10.1302/0301-620x.104b.bjj-2021-0397.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS A recent report from France suggested an association between the use of cobalt-chrome femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. Cobalt-chrome is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint replacements and other orthopaedic procedures in which cobalt-chrome is used annually. We examined whether cobalt-chrome-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years follow-up. We excluded any patients with bilateral THAs, knee replacements, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing cobalt-chrome or not containing cobalt-chrome. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS There were 158,677 individuals (42.4%) with an implant containing cobalt-chrome. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association that patients with cobalt-chrome implants had higher rates of any of the outcomes. CONCLUSION Cobalt-chrome-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of cobalt-chrome containing implants is not associated with significant adverse systemic effects.
Collapse
Affiliation(s)
- Kevin Deere
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Gulraj S Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Yoav Ben-Shlomo
- Department of Population Health Sciences, University of Bristol, Bristol, UK
| | - J Mark Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| | - Ashley W Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
- National Institute for Health Research, Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| | - Adrian Sayers
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Michael R Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
- National Institute for Health Research, Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| |
Collapse
|
6
|
van der Weegen W, Hoekstra H, Brakel K, Sijbesma T. Limited need for screening of metal-on-metal hip resurfacing patients beyond 10 years of follow-up. Hip Int 2022; 32:106-112. [PMID: 32340491 DOI: 10.1177/1120700020917939] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND National and international guidelines lack consistency on how to screen metal-on-metal (MoM) hip arthroplasty patients for adverse reactions to metal debris (ARMD). Long-term outcomes of MoM hip arthroplasty are scarce, hindering further development of such guidelines. We present the clinical, radiological and ARMD status of 158 cases of hip resurfacing with >10 years follow-up. METHODS A prospective analysis of a cohort of 298 consecutive hip resurfacing procedures was performed at a single institution. All patients underwent MARS-MRI scanning for pseudotumour screening at least once, regardless of symptoms. Implant survival and reasons for revision were analysed for all patients. Clinical, radiological and MARS-MRI results were analysed for 158 unrevised procedures with >10 years follow-up. RESULTS The implant survival was 85.9% at 14.5 years (95% CI, 81.9-90.6) with revision for all causes as endpoint and 92.3% with MoM disease-related revisions excluded (95% CI, 88.2-95.0). Of the 158 cases with >10 years follow-up, 1 had elevated metal ion levels, 29 had a stable C1 pseudotumour and 6 a stable C2 pseudotumour. All pseudotumours were observed within 3 years after initiating our intensified ARMD screening (2011), with no new pseudotumours observed after that period. CONCLUSIONS We suggest that follow-up of MoM hip resurfacing patients beyond 10 years after surgery can be done with large intervals (i.e. every 5 years), and only earlier if a patient becomes symptomatic.
Collapse
Affiliation(s)
| | - Henk Hoekstra
- Department of Orthopaedic Surgery, St. Anna Hospital, Geldrop, The Netherlands
| | - Koen Brakel
- Department of Radiology, St. Anna Hospital, Geldrop, The Netherlands
| | - Thea Sijbesma
- Department of Orthopaedic Surgery, St. Anna Hospital, Geldrop, The Netherlands
| |
Collapse
|
7
|
Badhe RV, Akinfosile O, Bijukumar D, Barba M, Mathew MT. Systemic toxicity eliciting metal ion levels from metallic implants and orthopedic devices - A mini review. Toxicol Lett 2021; 350:213-224. [PMID: 34252509 DOI: 10.1016/j.toxlet.2021.07.004] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 06/19/2021] [Accepted: 07/07/2021] [Indexed: 12/28/2022]
Abstract
The metal/metal alloy-based implants and prostheses are in use for over a century, and the rejections, revisions, and metal particle-based toxicities were reported concurrently. Complications developed due to metal ions, metal debris, and organo-metallic particles in orthopedic patients have been a growing concern in recent years. It was reported that local and systemic toxicity caused by such released products from the implants is one of the major reasons for implant rejection and revision. Even though the description of environmental metal toxicants and safety limits for their exposure to humans were well established in the literature, an effort was not adequately performed in the case of implant-based metal toxicology. Since the metal ion concentration in serum acts as a possible indicator of the systemic toxicity, this review summarizes the reported human serum safe limits, toxic limits, and concentration range (μg/L, ppb, etc.) for mild to severe symptoms of six (cardiac, hepatic, neuro, nephron, dermal and endocrine) systemic toxicities for twelve most commonly used metallic implants. It also covers the widely used metal ion quantification techniques and systemic toxicity treatments reported.
Collapse
Affiliation(s)
- Ravindra V Badhe
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Obakanyin Akinfosile
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Divya Bijukumar
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | | | - Mathew T Mathew
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA.
| |
Collapse
|
8
|
Jenkinson MRJ, Meek RMD, Tate R, MacMillan S, Grant MH, Currie S. Cobalt-induced cardiomyopathy - do circulating cobalt levels matter? Bone Joint Res 2021; 10:340-347. [PMID: 34053230 PMCID: PMC8242681 DOI: 10.1302/2046-3758.106.bjr-2020-0414.r2] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Elevated levels of circulating cobalt ions have been linked with a wide range of systemic complications including neurological, endocrine, and cardiovascular symptoms. Case reports of patients with elevated blood cobalt ions have described significant cardiovascular complications including cardiomyopathy. However, correlation between the actual level of circulating cobalt and extent of cardiovascular injury has not previously been performed. This review examines evidence from the literature for a link between elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties and cardiomyopathy. Correlation between low, moderate, and high blood cobalt with cardiovascular complications has been considered. Elevated blood cobalt at levels over 250 µg/l have been shown to be a risk factor for developing systemic complications and published case reports document cardiomyopathy, cardiac transplantation, and death in patients with severely elevated blood cobalt ions. However, it is not clear that there is a hard cut-off value and cardiac dysfunction may occur at lower levels. Clinical and laboratory research has found conflicting evidence of cobalt-induced cardiomyopathy in patients with MoM hips. Further work needs to be done to clarify the link between severely elevated blood cobalt ions and cardiomyopathy. Cite this article: Bone Joint Res 2021;10(6):340–347.
Collapse
Affiliation(s)
| | | | - Rothwell Tate
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | | | - M Helen Grant
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Susan Currie
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| |
Collapse
|
9
|
Distinct Concentration-Dependent Molecular Pathways Regulate Bone Cell Responses to Cobalt and Chromium Exposure from Joint Replacement Prostheses. Int J Mol Sci 2021; 22:ijms22105225. [PMID: 34069294 PMCID: PMC8156984 DOI: 10.3390/ijms22105225] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/07/2021] [Accepted: 05/08/2021] [Indexed: 12/27/2022] Open
Abstract
Systemic cobalt (Co) and chromium (Cr) concentrations may be elevated in patients with metal joint replacement prostheses. Several studies have highlighted the detrimental effects of this exposure on bone cells in vitro, but the underlying mechanisms remain unclear. In this study, we use whole-genome microarrays to comprehensively assess gene expression in primary human osteoblasts, osteoclast precursors and mature resorbing osteoclasts following exposure to clinically relevant circulating versus local periprosthetic tissue concentrations of Co2+ and Cr3+ ions and CoCr nanoparticles. We also describe the gene expression response in osteoblasts on routinely used prosthesis surfaces in the presence of metal exposure. Our results suggest that systemic levels of metal exposure have no effect on osteoblasts, and primarily inhibit osteoclast differentiation and function via altering the focal adhesion and extracellular matrix interaction pathways. In contrast, periprosthetic levels of metal exposure inhibit both osteoblast and osteoclast activity by altering HIF-1α signaling and endocytic/cytoskeletal genes respectively, as well as increasing inflammatory signaling with mechanistic implications for adverse reactions to metal debris. Furthermore, we identify gene clusters and KEGG pathways for which the expression correlates with increasing Co2+:Cr3+ concentrations, and has the potential to serve as early markers of metal toxicity. Finally, our study provides a molecular basis for the improved clinical outcomes for hydroxyapatite-coated prostheses that elicit a pro-survival osteogenic gene signature compared to grit-blasted and plasma-sprayed titanium-coated surfaces in the presence of metal exposure.
Collapse
|
10
|
Tower SS, Medlin DJ, Bridges RL, Cho CS. Corrosion of Polished Cobalt-Chrome Stems Presenting as Cobalt Encephalopathy. Arthroplast Today 2020; 6:1022-1027. [PMID: 33385045 PMCID: PMC7772456 DOI: 10.1016/j.artd.2020.10.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Revised: 10/09/2020] [Accepted: 10/15/2020] [Indexed: 12/29/2022] Open
Abstract
Adverse reactions to metallic debris from corrosion of polished cobalt-chromium–cemented femoral stems are reported. Cobaltism (systemic cobalt poisoning) has not been reported from this phenomenon. Three patients presented to their surgeon for ongoing care 10-20 years after primary metal-on-plastic hip arthroplasty with the same polished cobalt-chromium–cemented femoral stems (Heritage, Zimmer). Urine cobalt was elevated, and the patients had symptoms consistent with cobaltism. Quantitative-F16DG-PET-CT brain imaging was performed showing generalized and focal brain hypometabolism consistent with cobalt encephalopathy. At revision, all stems were well fixed and grossly corroded. At 1 year after revision, cobalturia and cognitive symptoms were resolved or improved. Mechanically assisted crevice corrosion at the polymethylmethacrylate interface is a complication of polished cobalt-chromium–cemented stems that can result in systemic cobalt exposure and toxic encephalopathy. Our cases had only minor periprosthetic symptoms. Patients implanted with polished cobalt-chromium–cemented stems warrant monitoring with urine cobalt. Patients with cobaltemia warrant an evaluation for toxic encephalopathy.
Collapse
Affiliation(s)
- Stephen S Tower
- Affiliated Professor Alaska's Medical School, Tower Orthopedic and Joint Replacement Clinic, Anchorage, AK, USA
| | | | | | - Christina S Cho
- Tower Orthopedic and Joint Replacement Clinic, Anchorage, AK, USA
| |
Collapse
|
11
|
Echocardiographic Changes in the Context of Metal-on-Metal Versus Nonmetal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2020; 35:3230-3236.e3. [PMID: 32665157 DOI: 10.1016/j.arth.2020.06.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 06/10/2020] [Accepted: 06/10/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND The purpose of this study is to determine if there is a difference in echocardiographic results between patients with metal-on-metal (MoM) vs non-MoM total hip arthroplasty (THA) and to determine if a correlation exists between serum metal levels and echocardiographic outcomes. METHODS Seventy-five patients with the same modular THA enrolled in this prospective cohort study, and 49 had MoM bearings. All patients had serum cobalt, chromium, and titanium levels drawn at 2 study visits with a transthoracic echocardiogram at the second visit. Serum metal concentrations and echocardiographic parameters were compared with 2-way t-tests. Multiple linear regression analyses identified any significant predictors of echocardiographic outcomes. RESULTS Mean serum cobalt and chromium levels were significantly greater in the MoM group at both time-points (P < .001 and P < .05, respectively). Titanium levels were similar between groups (P > .05). MoM patients had significantly lower global longitudinal strain compared with the non-MoM group (18.4% vs 20.2%; P = .026). Serum cobalt concentration was found to be an independent predictor of tricuspid annular plane systolic excursion (P = .02). CONCLUSION MoM THA bearings are associated with increased serum cobalt and chromium levels. Patients with MoM THAs had decreased global longitudinal strain, a measure of left ventricular function, but both groups remained within normal range. The clinical impact of the positive association between serum cobalt concentration and tricuspid annular plane systolic excursion, a marker of right ventricular function, deserves further study. These findings can reassure physicians and patients that metal-induced cardiomyopathy is not typical in the setting of MoM THA. LEVEL OF EVIDENCE Level II, Prospective Cohort Study.
Collapse
|
12
|
Cobalt Administration Causes Reduced Contractility with Parallel Increases in TRPC6 and TRPM7 Transporter Protein Expression in Adult Rat Hearts. Cardiovasc Toxicol 2020; 19:276-286. [PMID: 30523498 PMCID: PMC6505488 DOI: 10.1007/s12012-018-9498-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Exposure to circulating cobalt (Co2+) in patients with metal-on-metal orthopaedic hip implants has been linked to cardiotoxicity but the underlying mechanism(s) remain undefined. The aim of the current study was to examine the effects of Co2+ on the heart in vivo and specifically on cardiac fibroblasts in vitro. Adult male rats were treated with CoCl2 (1 mg/kg) for either 7 days or 28 days. Inductively coupled plasma mass spectrometry (ICP-MS) was used to measure Co2+ uptake into various organs of the body. Co2+ accumulated in the heart over time with significant levels evident after only 7 days of treatment. There was no evidence of cardiac remodelling following Co2+ treatment as assessed by heart weight:body weight and left ventricular weight:body weight. However, a decrease in fractional shortening, as measured using echocardiography, was observed after 28 days of Co2+ treatment. This was accompanied by increased protein expression of the ion transient receptor potential (TRP) channels TRPC6 and TRPM7 as assessed by quantitative immunoblotting of whole cardiac homogenates. Uptake of Co2+ specifically into rat cardiac fibroblasts was measured over 72 h and was shown to dramatically increase with increasing concentrations of applied CoCl2. Expression levels of TRPC6 and TRPM7 proteins were both significantly elevated in these cells following Co2+ treatment. In conclusion, Co2+ rapidly accumulates to significant levels in the heart causing compromised contractility in the absence of any overt cardiac remodelling. TRPC6 and TRPM7 expression levels are significantly altered in the heart following Co2+ treatment and this may contribute to the Co2+-induced cardiotoxicity observed over time.
Collapse
|
13
|
Self-reported systemic complaints in patients with metal-on-metal hip arthroplasty. J Orthop 2020; 18:213-217. [PMID: 32071507 DOI: 10.1016/j.jor.2020.01.032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 01/24/2020] [Indexed: 12/31/2022] Open
Abstract
Introduction An increase in blood serum metal ion levels is seen after implantation of all metal-on-metal (MoM) hip prosthesis. Systemic complaints contributed to raised cobalt ion concentrations in patients with MoM arthroplasty may lead to a variety of symptoms. The aim of this study is to investigate self-reported systemic complaints in association with cobalt ion concentrations in patients with any type of MoM hip prosthesis. Methods A cohort study was conducted. Patients with both unilateral and bilateral, resurfacing and large head metal on metal total hip arthroplasties (LHMoM THA) were included. Cobalt ion concentrations were measured by inductively coupled plasma mass spectrometry. Based on the known cobalt toxicity symptoms of case-reports and toxicology reports a new non-validated questionnaire was developed. Analysis was performed on two groups; a low cobalt ion concentration group and a high cobalt ion concentration group. Results A total of 62 patients were included with a mean age at surgery of 60.8 ± 9.3 years and a mean follow up of 6.3 ± 1.4 years. Mean cobalt ion concentrations were 104 ± 141 nmol/L (9-833). Based on the different thresholds (120-170 or 220 nmol/L) the low cobalt ion concentration group consisted of 44 (71%), 51 (82%) or 55 (89%) subjects respectively. In the 120 nmol/L and 170 nmol/L thresholds a significant difference in age was found. The composite score for OVS increased from 54% to 57%-68% with rising threshold value, a hint at the correlation between ion concentration and symptom prevalence. Discussion Ocular-vestibular symptoms were more common in high cobalt ion concentration groups for the three threshold levels tested and with increasing prevalence for higher threshold values. With regards to proactively inquired, self-reported symptoms the threshold where effects may be present could be lower than values currently applied in clinical follow-up.
Collapse
|
14
|
Lützner J, Günther KP, Postler A, Morlock M. Metal Ion Release after Hip and Knee Arthroplasty - Causes, Biological Effects and Diagnostics. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2019; 158:369-382. [PMID: 31820432 DOI: 10.1055/a-0929-8121] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
All metal implants in human bodies corrode which results in metal ions release. This is not necessarily a problem and represents for most patients no hazard. However, if a critical metal ion concentration is exceeded, local or rarely systemic problems can occur. This article summarizes the mechanisms of metal ion release and its clinical consequences. Several situations can result in increased metal ion release: metal-on-metal hip arthroplasties with increased wear, increased micromotion at taper interfaces, direct metal-metal contact (polyethylene wear, impingement), erroneously used metal heads after ceramic head fracture. Possible problems are in most cases located close to the concerned joint. Furthermore, there are reports about toxic damage to several organs. Most of these reports refer to erroneously used metal heads in revisions after a broken ceramic head. There is currently no evidence of carcinogenic or teratogenic effects of implants but data is not sufficient to exclude possible effects. Cobalt and chromium blood levels (favorably in whole blood) should be measured in patients with suspected elevated metal ions. According to current knowledge levels below 2 µg/l seem to be uncritical, levels between 2 and 7 µg/l are considered borderline with unknown biological consequences and levels above 7 µg/l indicate a local problem which should be further diagnosed. Metal ion levels always need to be interpreted together with clinical symptoms and imaging results.
Collapse
Affiliation(s)
- Jörg Lützner
- University Center of Orthopaedics and Trauma Surgery, TU Dresden
| | | | - Anne Postler
- University Center of Orthopaedics and Trauma Surgery, TU Dresden
| | | |
Collapse
|
15
|
Umar M, Jahangir N, Faisal Khan M, Saeed Z, Sultan F, Sultan A. Cobalt cardiomyopathy in hip arthroplasty. Arthroplast Today 2019; 5:371-375. [PMID: 31516984 PMCID: PMC6728440 DOI: 10.1016/j.artd.2019.04.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 04/26/2019] [Accepted: 04/27/2019] [Indexed: 01/25/2023] Open
Abstract
Background Cobalt toxicity-related cardiomyopathy in hip arthroplasty has recently been reported in the literature. The purpose of this review is to identify and assess available published evidence of cardiomyopathy in hip arthroplasty patients and to derive recommendations for management. Methods We evaluated 23 cases reported until October 2018 and stratified them into 3 categories, based upon pre-existing risk factors for cardiomyopathy, histological confirmation, and evidence of systemic signs of cobalt toxicity. Results Cobalt toxicity was considered to be the definite cause of cardiomyopathy in 8 cases, and probably contributory in 13 cases. Two cases were considered to have developed cardiomyopathy secondary to pre-existing risk factors. Majority of the patients had a good recovery of cardiac function after hip revision and cardiac management, but 5 cases deteriorated and died. Conclusions Although cobalt-related cardiomyopathy has been reported in a small number of cases of hip arthroplasty, a delay or missed diagnosis may lead to significant morbidity and mortality. Timely diagnosis, removal of causative implant, and avoidance of metal articulations in revision for fractured ceramic implants may help in an effective management.
Collapse
Affiliation(s)
- Muhammad Umar
- Department of Trauma and Orthopaedics, Macclesfield District General Hospital, Macclesfield, UK
| | - Noman Jahangir
- Department of Trauma and Orthopaedics, Wythenshawe Hospital, Manchester, UK
| | | | - Zobia Saeed
- Department of Trauma and Orthopaedics, Macclesfield District General Hospital, Macclesfield, UK
| | - Farina Sultan
- Department of Cardiology, Royal Albert Edward Infirmary Wrightington, Wigan & Leigh NHS Foundation Trust, Wigan, UK
| | - Ayyaz Sultan
- Department of Cardiology, Royal Albert Edward Infirmary Wrightington, Wigan & Leigh NHS Foundation Trust, Wigan, UK
| |
Collapse
|
16
|
Manisty C, Skinner J, Moon JC. Metal-on-metal hips and heart failure - Can we relax? Int J Cardiol 2019; 284:65-66. [PMID: 30224256 DOI: 10.1016/j.ijcard.2018.09.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 08/22/2018] [Accepted: 09/03/2018] [Indexed: 11/29/2022]
Affiliation(s)
- Charlotte Manisty
- Institute of Cardiovascular Sciences, University College London, UK; Department of Cardiac Imaging, Barts Heart Centre, London, UK.
| | - John Skinner
- Department of Orthopaedics, Royal National Orthopaedic Hospital, Stanmore, UK
| | - James C Moon
- Institute of Cardiovascular Sciences, University College London, UK; Department of Cardiac Imaging, Barts Heart Centre, London, UK
| |
Collapse
|
17
|
Juneau D, Grammatopoulos G, Alzahrani A, Thornhill R, Inacio JR, Dick A, Vogel KI, Dobransky J, Beaulé PE, Dwivedi G. Is end-organ surveillance necessary in patients with well-functioning metal-on-metal hip resurfacings? Bone Joint J 2019; 101-B:540-546. [DOI: 10.1302/0301-620x.101b5.bjj-2018-1478.r1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Aims Cardiac magnetic resonance (CMR) was used to assess whether cardiac function or tissue composition was affected in patients with well-functioning metal-on-metal hip resurfacing arthroplasties (MoMHRA) when compared with a group of controls, and to assess if metal ion levels correlated with any of the functional or structural parameters studied. Patients and Methods In all, 30 participants with no significant cardiac history were enrolled: 20 patients with well-functioning MoMHRA at mean follow-up of 8.3 years post-procedure (ten unilateral, ten bilateral; 17 men, three women) and a case-matched control group of ten non-MoM total hip arthroplasty patients (six men, four women). The mean age of the whole cohort (study group and controls) at the time of surgery was 50.6 years (41.0 to 64.0). Serum levels of cobalt and chromium were measured, and all patients underwent CMR imaging, including cine, T2* measurements, T1 and T2 mapping, late gadolinium enhancement, and strain measurements. Results None of the MoMHRA patients showed clinically significant cardiac functional abnormality. The MoMHRA patients had larger indexed right and left end diastolic volumes (left ventricular (LV): 74 ml/m2 vs 67 ml/m2, p = 0.045; right ventricular: 80 ml/m2 vs 71 ml/m2, p = 0.02). There was a small decrease in T2 time in the MoMHRA patients (median 49 ms vs 54 ms; p = 0.0003). Higher metal ion levels were associated with larger LV volumes and with shorter T2 time. Conclusion Although cardiac function is not clinically adversely affected in patients with well-functioning MoMHRA, modern imaging is able to demonstrate subtle changes in structure and function of the heart. As these changes correlate with systemic ion measurements, they may be consequences of wear debris deposition. Longer, longitudinal studies are necessary to determine whether cardiac function will become affected. Cite this article: Bone Joint J 2019;101-B:540–546.
Collapse
Affiliation(s)
- D. Juneau
- Department of Radiology and Nuclear Medicine, Centre Hospitalier de l’Université de Montréal (CHUM), Montréal, Canada
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
| | - G. Grammatopoulos
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - A. Alzahrani
- King Saud bin Abdulaziz University for Health Sciences, King Faisal Cardiac Center, Jeddah, Saudi Arabia
| | - R. Thornhill
- The Ottawa Hospital, Department of Medical Imaging, Ottawa, Canada
| | - J. R. Inacio
- The Ottawa Hospital, Department of Medical Imaging, Ottawa, Canada
| | - A. Dick
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
| | - K. I. Vogel
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - J. Dobransky
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
| | - P. E. Beaulé
- Division of Orthopaedic Surgery, University of Ottawa Faculty of Medicine, The Ottawa Hospital, Ottawa, Canada
- University of Ottawa, Ottawa, Canada
| | - G. Dwivedi
- University of Ottawa Heart Institute, Division of Cardiology, Department of Medicine, Ottawa, Canada
- Consultant in Cardiology and Professor of Cardiology, The University of Western Australia, Harry Perkins Institute of Medical Research and Fiona Stanley Hospital, Perth, Australia
| |
Collapse
|
18
|
Abstract
This article discusses developments in total hip arthroplasty related to the use of highly cross-linked polyethylene (HXLPE) liner material as the new standard of care for acetabular cup articulation surfaces. The pathologic implications of metal-on-metal hip prostheses in asymptomatic patients also are discussed.
Collapse
|
19
|
Lodge F, Khatun R, Lord R, John A, Fraser A, Yousef Z. Prevalence of subclinical cardiac abnormalities in patients with metal-on-metal hip replacements. Int J Cardiol 2018; 271:274-280. [DOI: 10.1016/j.ijcard.2018.05.047] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 05/08/2018] [Accepted: 05/15/2018] [Indexed: 10/16/2022]
|
20
|
Hernández-Vaquero D, García-Pascual M, Iglesias-Fernández S, Escandon-Rodríguez A. Metal-on-metal surface hip arthroplasties. Is annual monitoring of blood metal levels necessary? Rev Esp Cir Ortop Traumatol (Engl Ed) 2018. [DOI: 10.1016/j.recote.2018.03.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
|
21
|
Affiliation(s)
- Philippe Hantson
- Department of Intensive Care, Cliniques St-Luc, Université catholique de Louvain, Brussels, Belgium
- Louvain Centre for Toxicology and Applied Pharmacology, Cliniques St-Luc, Université catholique de Louvain, Brussels, Belgium
| |
Collapse
|
22
|
CORR Insights®: Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases. Clin Orthop Relat Res 2018; 476:1452-1454. [PMID: 29846204 PMCID: PMC6437569 DOI: 10.1097/corr.0000000000000355] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
23
|
Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases. Clin Orthop Relat Res 2018; 476:1441-1451. [PMID: 29698302 PMCID: PMC6259674 DOI: 10.1097/01.blo.0000533617.64678.69] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND There are four distinguishable types of THA devices in wide use, as defined by the femoral and acetabular bearing surfaces: metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). Metallic head THAs (MoP and MoM) can potentially induce cardiac toxicity because cobalt species, generated at the head-neck trunnion, and in the case of MoM devices, at the articular surface as well, can be absorbed systemically. However, studies have provided inconsistent results. QUESTIONS/PURPOSES The purpose of this study was to assess the risk of dilated cardiomyopathy (DCM) or heart failure (HF) associated with metallic head THAs using data from the French national health insurance databases. METHODS Between 2008 and 2011 in France, 399,968 patients ≥ 55 years had a first THA. A total of 127,481 were excluded after we applied the exclusion criteria regarding arthroplasty and 17,137 as a result of a history of DCM/HF, recorded in the French national health insurance reimbursement databases, between January 1, 2006, and the date of inclusion. The final cohort included 255,350 individuals (43% men; mean age 72 ± 9 years). Of them, 93,581 (37%) had been implanted with MoP, 58,095 (23%) with CoP, 11,298 (4%) with MoM, and 92,376 (36%) with CoC THAs. Patients were followed until December 2015. Patients with incident DCM/HF were identified by a new entitlement to the long-term disease scheme or a first hospitalization with a diagnosis of DCM or HF. MoP and CoP THAs are generally implanted in old patients, whereas MoM and CoC are mostly indicated in young, active male patients. Thus, to consider the specific indications of the bearing couples, analyses were separately performed in two distinct subcohorts, one comprising patients with MoP or CoP and one comprising patients with MoM or CoC THA. In each subcohort, the DCM/HF risk was compared between patients with metallic head versus nonmetallic head THAs (MoP versus CoP, MoM versus CoC). Hazard ratios (adjusted HRs) of incident DCM/HF were estimated using Cox models adjusted for baseline sex, age, THA characteristics (fixation technique with cement, use of a modular femoral neck), and comorbidities at baseline. Cox models were stratified by sex and age. RESULTS The crude incidence of DCM/HF per 100 person-years was 2.4 in patients with MoP, 1.8 with CoP, 1.2 with MoM, and 1.1 with CoC THAs. Overall, metallic head THAs were associated with a slight increase in DCM/HF risk (MoP versus CoP: adjusted HR, 1.08; 95% confidence interval [CI], 1.05-1.12; p < 0.001; MoM versus CoC: adjusted HR, 1.11; 95% CI, 1.03-1.19; p = 0.007). In the MoM-CoC subcohort, the risk tended to be more pronounced with MoM versus CoC THAs in women (MoM versus CoC: adjusted HR, 1.20; 95% CI, 1.07-1.35; p = 0.002) and patients aged ≥ 75 years (MoM versus CoC: adjusted HR, 1.16; 95% CI, 1.04-1.29; p = 0.009). CONCLUSIONS Metallic head THAs were associated with a slightly increased DCM/HF risk, especially with MoM in women and older patients. Some caveats should be mentioned: severity of DCM or HF was not available and residual confounding cannot be ruled out despite considering many covariates. Our findings suggest that cardiac function should be regularly monitored in patients with metallic head THAs. Further investigations should be planned on large international cohorts. LEVEL OF EVIDENCE Level III, therapeutic study.
Collapse
|
24
|
Hernández-Vaquero D, García-Pascual M, Iglesias-Fernández S, Escandon-Rodríguez A. Metal-on-metal surface hip arthroplasties. Is annual monitoring of blood metal levels necessary? Rev Esp Cir Ortop Traumatol (Engl Ed) 2018; 62:436-441. [PMID: 29884514 DOI: 10.1016/j.recot.2018.03.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Revised: 02/19/2018] [Accepted: 03/13/2018] [Indexed: 11/27/2022] Open
Abstract
INTRODUCTION Blood cobalt (Co) and chromium (Cr) ion levels have been used as surveillance tools for adverse reaction to metal debris in metal-on-metal (MoM) hip arthroplasty. The aim of our study was to present serial 7-13 year blood Co and Cr levels in a cohort of MoM total hip arthroplasties in asymptomatic patients. MATERIAL AND METHODS A total of 52 MoM surface total hip arthroplasties were included in this study with data collected prospectively. Annual follow-up with blood Co and Cr measurements was performed. Revision surgery was necessary for 16 patients and therefore they dropped out of the study. The metal ion levels were analyzed separately in 31 asymptomatic patients. RESULTS High Cr or Co levels were not found continuously in any of the asymptomatic patients. The median Cr in blood was maintained between 1.3 and 5.4μg/L and that of Co between 0.5 and 1.2μg/L. After 7 years, there was no significant change in Co and Cr values. CONCLUSION In the medium term and in asymptomatic patients, the metallic blood levels remained unchanged; therefore, it does not seem appropriate to repeat these tests on a permanent basis in annual controls.
Collapse
Affiliation(s)
- D Hernández-Vaquero
- Departamento de Cirugía, Facultad de Medicina, Universidad de Oviedo, Oviedo, España; Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España.
| | - M García-Pascual
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| | - S Iglesias-Fernández
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| | - A Escandon-Rodríguez
- Servicio de Cirugía Ortopédica y Traumatología, Hospital Universitario San Agustín, Avilés, España
| |
Collapse
|
25
|
Goodnough LH, Bala A, Huddleston J, Goodman SB, Maloney WJ, Amanatullah DF. Metal-on-metal total hip arthroplasty is not associated with cardiac disease. Bone Joint J 2018; 100-B:28-32. [PMID: 29305447 DOI: 10.1302/0301-620x.100b1.bjj-2017-0366.r1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Many case reports and small studies have suggested that cobalt ions are a potential cause of cardiac complications, specifically cardiomyopathy, after metal-on-metal (MoM) total hip arthroplasty (THA). The impact of metal ions on the incidence of cardiac disease after MoM THA has not been evaluated in large studies. The aim of this study was to compare the rate of onset of new cardiac symptoms in patients who have undergone MoM THA with those who have undergone metal-on-polyethylene (MoP) THA. PATIENTS AND METHODS Data were extracted from the Standard Analytics Files database for patients who underwent MoM THA between 2005 and 2012. Bearing surface was selected using International Classification of Diseases ninth revision codes. Patients with a minimum five-year follow-up were selected. An age and gender-matched cohort of patients who underwent MoP THA served as a comparison group. New diagnoses of cardiac disease were collected during the follow-up period. Comorbidities and demographics were identified and routine descriptive statistics were used. RESULTS We identified 29 483 patients who underwent MoM THA and 24 175 matched patients who underwent MoP THA. Both groups had a mean Charlson comorbidity index score of 4. There were no statistically significant differences in 30 of 31 pre-existing comorbidities. Patients undergoing MoM THA had a slightly lower incidence of cardiac failure compared with those undergoing MoP THA at three years (6.60% versus 7.06%, odds ratio (OR) 0.93, 95% confidence interval (CI) 0.87 to 0.99) and four years (8.73% versus 9.49%, OR 0.91, 95% CI 0.86 to 0.97) postoperatively, with no difference in the incidence of new cardiac failure in between the groups at five years. There was no statistically significant difference in the incidence of arrhythmia, myocardial infarction and cardiomyopathy at any time between the two groups. CONCLUSION MoM THA is not associated with cardiac complications. Initial reports may have represented individual instances of cardiac disease in patients with a failing MoM articulation rather than an emerging epidemiological trend. Cite this article: Bone Joint J 2018;100-B:28-32.
Collapse
Affiliation(s)
- L H Goodnough
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - A Bala
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - J Huddleston
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - S B Goodman
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - W J Maloney
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| | - D F Amanatullah
- Stanford University, 450 Broadway Street, Redwood City, California, 94063, USA
| |
Collapse
|
26
|
Sabah SA, Moon JC, Jenkins-Jones S, Morgan CL, Currie CJ, Wilkinson JM, Porter M, Captur G, Henckel J, Chaturvedi N, Kay P, Skinner JA, Hart AJ, Manisty C. The risk of cardiac failure following metal-on-metal hip arthroplasty. Bone Joint J 2018; 100-B:20-27. [PMID: 29305446 PMCID: PMC6424145 DOI: 10.1302/0301-620x.100b1.bjj-2017-1065.r1] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
AIMS The aim of this study was to determine whether patients with metal-on-metal (MoM) arthroplasties of the hip have an increased risk of cardiac failure compared with those with alternative types of arthroplasties (non-MoM). PATIENTS AND METHODS A linkage study between the National Joint Registry, Hospital Episodes Statistics and records of the Office for National Statistics on deaths was undertaken. Patients who underwent elective total hip arthroplasty between January 2003 and December 2014 with no past history of cardiac failure were included and stratified as having either a MoM (n = 53 529) or a non-MoM (n = 482 247) arthroplasty. The primary outcome measure was the time to an admission to hospital for cardiac failure or death. Analysis was carried out using data from all patients and from those matched by propensity score. RESULTS The risk of cardiac failure was lower in the MoM cohort compared with the non-MoM cohort (adjusted hazard ratio (aHR) 0.901; 95% confidence interval (CI) 0.853 to 0.953). The risk of cardiac failure was similar following matching (aHR 0.909; 95% CI 0.838 to 0.987) and the findings were consistent in subgroup analysis. CONCLUSION The risk of cardiac failure following total hip arthroplasty was not increased in those in whom MoM implants were used, compared with those in whom other types of prostheses were used, in the first seven years after surgery. Cite this article: Bone Joint J 2018;100-B:20-7.
Collapse
Affiliation(s)
- S A Sabah
- Royal National Orthopaedic Hospital, Stanmore, Middlesex and University College London, London, UK
| | - J C Moon
- Institute of Cardiovascular Sciences, University College London and Barts Heart Centre, London, UK
| | - S Jenkins-Jones
- Division of Surgery and Interventional Sciences, University College London, UK and Global Epidemiology and Medical Statistics, Pharmatelligence, Cardiff, UK
| | - C Ll Morgan
- Division of Surgery and Interventional Sciences, University College London, UK and Global Epidemiology and Medical Statistics, Pharmatelligence, Cardiff, UK
| | - C J Currie
- Global Epidemiology and Medical Statistics, Pharmatelligence, Cardiff, UK and Division of Population Medicine, School of Medicine, Cardiff University, Cardiff, UK
| | - J M Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK and National Joint Registry for England, Wales and Northern Ireland
| | - M Porter
- Centre for Hip Surgery, Wrightington Hospital, Wigan, UK
| | - G Captur
- Institute of Cardiovascular Sciences, University College London, UK and Department of Cardiology, Barts Heart Centre, London, UK
| | - J Henckel
- Royal National Orthopaedic Hospital, Stanmore, UK and Division of Surgery and Interventional Sciences, University College London, UK
| | - N Chaturvedi
- Institute of Cardiovascular Sciences, University College London, London, UK
| | - P Kay
- Wrightington Hospital, Wigan, UK
| | - J A Skinner
- Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| | - A J Hart
- Royal National Orthopaedic Hospital, Stanmore, Middlesex, UK
| | - C Manisty
- Institute of Cardiovascular Sciences, University College London, UK and Department of Cardiology, Barts Heart Centre, London, UK
| |
Collapse
|
27
|
Fung ES, Monnot A, Kovochich M, Unice KM, Tvermoes BE, Galbraith D, Finley BL, Paustenbach DJ. Characteristics of Cobalt-Related Cardiomyopathy in Metal Hip Implant Patients: An Evaluation of 15 Published Reports. Cardiovasc Toxicol 2017; 18:206-220. [PMID: 29188590 DOI: 10.1007/s12012-017-9433-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Over 300,000 hip replacements occurred in the USA in 2010, and the frequency is likely increasing annually. Blood Cobalt (Co) concentrations in patients with well-functioning cobalt-chromium (Co-Cr) hip implants are usually elevated above background concentrations relative to the general population. Excessive Co exposure, in rare cases, can result in cardiomyopathy. The purpose of this review was to identify cases of cardiomyopathy in metal-containing hip implant patients and to evaluate the possible cause of each patient's cardiomyopathy. We evaluated 15 cases published between 2009 and 2016, and, based on a review of the preexisting risk factors, blood Co concentrations, and histopathological information published for each patient, they were stratified into one of four categories regarding the association between Co exposure and the development of cardiomyopathy: (1) Co was causal (five cases); (2) Co was contributory (two cases); (3) Co was possibly contributory (six cases); and (4) Co was non-causal (two cases). In all 15 cases, blood Co concentrations (14-6521 μg/L) were elevated beyond levels associated with the majority of metal-containing implant patients (0.1-10 μg/L), and, in many cases, there was evidence of a malfunctioning implant. The data indicate that individuals with well-functioning implants, even those with preexisting risk factors, are at no risk of developing cardiac effects. We conclude that blood Co measurements are informative, but should be interpreted with caution, and in context of other factors evaluated in this analysis. The mere presence of elevated Co is not sufficient to indicate causation for a patient's cardiomyopathy.
Collapse
Affiliation(s)
- Ernest S Fung
- Cardno ChemRisk, 65 Enterprise, Suite 150, Aliso Viejo, CA, 92656, USA
| | - Andrew Monnot
- Cardno ChemRisk, 101 2nd St. Suite 700, San Francisco, CA, 94105, USA
| | - Michael Kovochich
- Cardno ChemRisk, 65 Enterprise, Suite 150, Aliso Viejo, CA, 92656, USA.
| | - Kenneth M Unice
- Cardno ChemRisk, 20 Stanwix St. Suite 505, Pittsburgh, PA, 15222, USA
| | - Brooke E Tvermoes
- Cardno ChemRisk, 4940 Pearl East Circle Suite 100, Boulder, CO, 80301, USA.,IBM, Boulder, CO, USA
| | - David Galbraith
- Cardno ChemRisk, 101 2nd St. Suite 700, San Francisco, CA, 94105, USA
| | - Brent L Finley
- Cardno ChemRisk, 231 Front St. Suite 212, Brooklyn, NY, 11201, USA
| | | |
Collapse
|
28
|
Berber R, Abdel-Gadir A, Rosmini S, Captur G, Nordin S, Culotta V, Palla L, Kellman P, Lloyd GW, Skinner JA, Moon JC, Manisty C, Hart AJ. Assessing for Cardiotoxicity from Metal-on-Metal Hip Implants with Advanced Multimodality Imaging Techniques. J Bone Joint Surg Am 2017; 99:1827-1835. [PMID: 29088037 PMCID: PMC6948834 DOI: 10.2106/jbjs.16.00743] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND High failure rates of metal-on-metal (MoM) hip implants prompted regulatory authorities to issue worldwide safety alerts. Circulating cobalt from these implants causes rare but fatal autopsy-diagnosed cardiotoxicity. There is concern that milder cardiotoxicity may be common and underrecognized. Although blood metal ion levels are easily measured and can be used to track local toxicity, there are no noninvasive tests for organ deposition. We sought to detect correlation between blood metal ions and a comprehensive panel of established markers of early cardiotoxicity. METHODS Ninety patients were recruited into this prospective single-center blinded study. Patients were divided into 3 age and sex-matched groups according to implant type and whole-blood metal ion levels. Group-A patients had a ceramic-on-ceramic [CoC] bearing; Group B, an MoM bearing and low blood metal ion levels; and Group C, an MoM bearing and high blood metal-ion levels. All patients underwent detailed cardiovascular phenotyping using cardiac magnetic resonance imaging (CMR) with T2*, T1, and extracellular volume mapping; echocardiography; and cardiac blood biomarker sampling. T2* is a novel CMR biomarker of tissue metal loading. RESULTS Blood cobalt levels differed significantly among groups A, B, and C (mean and standard deviation [SD], 0.17 ± 0.08, 2.47 ± 1.81, and 30.0 ± 29.1 ppb, respectively) and between group A and groups B and C combined. No significant between-group differences were found in the left atrial or ventricle size, ejection fraction (on CMR or echocardiography), T1 or T2* values, extracellular volume, B-type natriuretic peptide level, or troponin level, and all values were within normal ranges. There was no relationship between cobalt levels and ejection fraction (R = 0.022, 95% confidence interval [CI] = -0.185 to 0.229) or T2* values (R = 0.108, 95% CI = -0.105 to 0.312). CONCLUSIONS Using the best available technologies, we did not find that high (but not extreme) blood cobalt and chromium levels had any significant cardiotoxic effect on patients with an MoM hip implant. There were negligible-to-weak correlations between elevated blood metal ion levels and ejection fraction even at the extremes of the 95% CI, which excludes any clinically important association. LEVEL OF EVIDENCE Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Reshid Berber
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom,E-mail address for R. Berber:
| | - Amna Abdel-Gadir
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom,Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, London, United Kingdom
| | - Stefania Rosmini
- Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, London, United Kingdom
| | - Gabriella Captur
- NIHR University College London Hospitals Biomedical Research Centre, London, United Kingdom
| | - Sabrina Nordin
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom,Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, London, United Kingdom
| | - Veronica Culotta
- Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, London, United Kingdom
| | - Luigi Palla
- Faculty of Epidemiology and Population Health, London School of Hygiene and Tropical Medicine, London, United Kingdom
| | - Peter Kellman
- Medical Signal and Image Processing Program, National Heart, Lung, and Blood Institute, Bethesda, Maryland
| | - Guy W. Lloyd
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom,Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, London, United Kingdom
| | - John A. Skinner
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom
| | - James C. Moon
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom,Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, London, United Kingdom
| | - Charlotte Manisty
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom,Barts Heart Center, The Cardiovascular Magnetic Resonance Imaging Unit, St Bartholomew’s Hospital, London, United Kingdom
| | - Alister J. Hart
- Royal National Orthopaedic Hospital, Institute of Orthopaedics and Musculoskeletal Sciences (R.B., J.A.S., and A.J.H.) and Institute of Cardiovascular Science (A.A.-G., S.N., G.W.L., J.C.M., and C.M.), University College London, London, United Kingdom
| |
Collapse
|
29
|
Steinberg J, Shah KM, Gartland A, Zeggini E, Wilkinson JM. Effects of chronic cobalt and chromium exposure after metal-on-metal hip resurfacing: An epigenome-wide association pilot study. J Orthop Res 2017; 35:2323-2328. [PMID: 28098396 PMCID: PMC5655715 DOI: 10.1002/jor.23525] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2016] [Accepted: 01/06/2017] [Indexed: 02/04/2023]
Abstract
Metal-on-metal (MOM) hip resurfacing has recently been a popular prosthesis choice for the treatment of symptomatic arthritis, but results in the release of cobalt and chromium ions into the circulation that can be associated with adverse clinical effects. The mechanism underlying these effects remains unclear. While chromosomal aneuploidy and translocations are associated with this exposure, the presence of subtle structural epigenetic modifications in patients with MOM joint replacements remains unexplored. Consequently, we analyzed whole blood DNA methylation in 34 OA patients with MOM hip resurfacing (MOM HR) compared to 34 OA patients with non-MOM total hip replacements (non-MOM THR), using the genome-wide Illumina HumanMethylation 450k BeadChip. No probes showed differential methylation significant at 5% false-discovery rate (FDR). We also tested association of probe methylation levels with blood chromium and cobalt levels directly; there were no significant associations at 5% FDR. Finally, we used the "epigenetic clock" to compare estimated to actual age at sample for all individuals. We found no significant difference between MOM HR and non-MOM THR, and no correlation of age acceleration with blood metal levels. Our results suggest the absence of large methylation differences systemically following metal exposure, however, larger sample sizes will be required to identify potential small effects. Any DNA methylation changes that may occur in the local periprosthetic tissues remain to be elucidated. © 2017 The Authors. Orthopaedic Research Society. Published by Wiley Periodicals, Inc. on behalf of Orthopaedic Research Society. J Orthop Res 35:2323-2328, 2017.
Collapse
Affiliation(s)
| | - Karan M. Shah
- Department of Oncology and Metabolism, The Mellanby Centre for Bone ResearchThe University of SheffieldSheffieldUK
| | - Alison Gartland
- Department of Oncology and Metabolism, The Mellanby Centre for Bone ResearchThe University of SheffieldSheffieldUK
| | | | - Jeremy Mark Wilkinson
- Department of Oncology and Metabolism, The Mellanby Centre for Bone ResearchThe University of SheffieldSheffieldUK
| |
Collapse
|
30
|
Gillam MH, Pratt NL, Inacio MCS, Roughead EE, Shakib S, Nicholls SJ, Graves SE. Heart failure after conventional metal-on-metal hip replacements. Acta Orthop 2017; 88:2-9. [PMID: 27759468 PMCID: PMC5251259 DOI: 10.1080/17453674.2016.1246276] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Background and purpose - It is unclear whether metal particles and ions produced by mechanical wear and corrosion of hip prostheses with metal-on-metal (MoM) bearings have systemic adverse effects on health. We compared the risk of heart failure in patients with conventional MoM total hip arthroplasty (THA) and in those with metal-on-polyethylene (MoP) THA. Patients and methods - We conducted a retrospective cohort study using data from the Australian Government Department of Veterans' Affairs health claims database on patients who received conventional THA for osteoarthritis between 2004 and 2012. The MoM THAs were classified into groups: Articular Surface Replacement (ASR) XL Acetabular System, other large-head (LH) (> 32 mm) MoM, and small-head (SH) (≤ 32 mm) MoM. The primary outcome was hospitalization for heart failure after THA. Results - 4,019 patients with no history of heart failure were included (56% women). Men with an ASR XL THA had a higher rate of hospitalization for heart failure than men with MoP THA (hazard ratio (HR) = 3.2, 95% CI: 1.6-6.5). No statistically significant difference in the rate of heart failure was found with the other LH MoM or SH MoM compared to MoP in men. There was no statistically significant difference in heart failure rate between exposure groups in women. Interpretation - An association between ASR XL and hospitalization for heart failure was found in men. While causality between ASR XL and heart failure could not be established in this study, it highlights an urgent need for further studies to investigate the possibility of systemic effects associated with MoM THA.
Collapse
Affiliation(s)
- Marianne H Gillam
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia,Correspondence:
| | - Nicole L Pratt
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia
| | - Maria C S Inacio
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia
| | - Elizabeth E Roughead
- School of Pharmacy and Medical Sciences, The Quality Use of Medicines and Pharmacy Research Centre, University of South Australia
| | - Sepehr Shakib
- Department of Clinical Pharmacology, School of Medicine, University of Adelaide
| | - Stephen J Nicholls
- Department of Medicine, University of Adelaide and South Australian Health and Medical Research Institute, University of Adelaide
| | - Stephen E Graves
- Flinders University School of Medicine, Flinders University, Adelaide and Australian Orthopaedic Association National Joint Replacement Registry, Adelaide, Australia
| |
Collapse
|
31
|
Abstract
Cobalt can cause a distinctive, rapidly progressive and reversible depression of cardiac systolic function, which is readily distinguished from other causes of cardiomyopathy. Patients present with the subacute onset of severe heart failure, which is accompanied by hypotension and cyanosis, pericardial effusion, low voltage on the electrocardiogram, marked elevation of serum enzymes, and lactic acidosis. They typically have a history of lethargy, anorexia, and weight loss in the months preceding the illness and exhibit other evidence of cobalt’s effects on the body (eg, polycythemia and goiter). The course of cobalt-related cardiomyopathy may be progressive and fatal, but those who survive and cease exposure generally demonstrate complete resolution of symptoms and recovery of cardiac function. Patients presenting with rapid onset of cardiomyopathy, who also exhibit polycythemia, pericardial effusion, or goiter should be evaluated for cobalt exposure. Exposure can be confirmed by the measurement of cobalt in the serum, but serum levels of the ion are not reliably predictive of clinical cardiotoxicity. The clinical emergence of cobalt cardiomyopathy seems to require the coexistence of one or more cofactors, particularly a low-protein diet, thiamine deficiency, alcoholism, and hypothyroidism. As the medicinal use of cobalt has waned and measures to reduce industrial exposure have been implemented, subacute cobalt-related cardiomyopathy had become rare. However, reports describing classical features of the disease have recently surged among patients with a malfunctioning cobalt-alloy hip prosthesis.
Collapse
Affiliation(s)
- Milton Packer
- From the Baylor Heart and Vascular Institute, Baylor University Medical Center, Dallas, TX
| |
Collapse
|
32
|
Pulikottil-Jacob R, Connock M, Kandala NB, Mistry H, Grove A, Freeman K, Costa M, Sutcliffe P, Clarke A. Has Metal-On-Metal Resurfacing Been a Cost-Effective Intervention for Health Care Providers?-A Registry Based Study. PLoS One 2016; 11:e0165021. [PMID: 27802289 PMCID: PMC5089767 DOI: 10.1371/journal.pone.0165021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Accepted: 10/05/2016] [Indexed: 12/01/2022] Open
Abstract
Background Total hip replacement for end stage arthritis of the hip is currently the most common elective surgical procedure. In 2007 about 7.5% of UK implants were metal-on-metal joint resurfacing (MoM RS) procedures. Due to poor revision performance and concerns about metal debris, the use of RS had declined by 2012 to about a 1% share of UK hip procedures. This study estimated the lifetime cost-effectiveness of metal-on-metal resurfacing (RS) procedures versus commonly employed total hip replacement (THR) methods. Methodology/Principal Findings We performed a cost-utility analysis using a well-established multi-state semi-Markov model from an NHS and personal and social services perspective. We used individual patient data (IPD) from the National Joint Registry (NJR) for England and Wales on RS and THR surgery for osteoarthritis recorded from April 2003 to December 2012. We used flexible parametric modelling of NJR RS data to guide identification of patient subgroups and RS devices which delivered revision rates within the NICE 5% revision rate benchmark at 10 years. RS procedures overall have an estimated revision rate of 13% at 10 years, compared to <4% for most THR devices. New NICE guidance now recommends a revision rate benchmark of <5% at 10 years. 60% of RS implants in men and 2% in women were predicted to be within the revision benchmark. RS devices satisfying the 5% benchmark were unlikely to be cost-effective compared to THR at a standard UK willingness to pay of £20,000 per quality-adjusted life-year. However, the probability of cost effectiveness was sensitive to small changes in the costs of devices or in quality of life or revision rate estimates. Conclusion/Significance Our results imply that in most cases RS has not been a cost-effective resource and should probably not be adopted by decision makers concerned with the cost effectiveness of hip replacement, or by patients concerned about the likelihood of revision, regardless of patient age or gender.
Collapse
Affiliation(s)
- Ruth Pulikottil-Jacob
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
| | - Martin Connock
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
| | - Ngianga-Bakwin Kandala
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
- Northumbria University, Department of Mathematics, Physics and Electrical Engineering, Faculty of Engineering and Environment, Newcastle upon Tyne, United Kingdom
| | - Hema Mistry
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
| | - Amy Grove
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
| | - Karoline Freeman
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
| | - Matthew Costa
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
| | - Paul Sutcliffe
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
| | - Aileen Clarke
- Warwick Evidence, Division of Health Sciences, Warwick Medical School, University of Warwick, Coventry, United Kingdom
- * E-mail:
| |
Collapse
|
33
|
Lessons learnt from metal-on-metal hip arthroplasties will lead to safer innovation for all medical devices. Hip Int 2016; 25:347-54. [PMID: 26165359 DOI: 10.5301/hipint.5000275] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 05/05/2015] [Indexed: 02/06/2023]
Abstract
Metal-on-metal bearings were re-popularised in the late 1990s with the introduction of modern hip resurfacing. Large diameter (LD) metal-on-metal (MoM) hips became more prevalent and have been the least successful group of hip implants ever used. They were rapidly adopted from 2004 until the British Hip Society stopped their use in 2012. Well functioning MoM hip results (including the BHR and Metasul) are hidden in the mire of poor results from the group of all MoM bearings.We have reviewed what happened and we make 3 observations. Firstly, collaboration between surgeons and then between surgeons and other disciplines, first identified and then solved the clinical management problems. Secondly, the problems with MoM hips occurred because hip simulation was inadequate at predicting performance in patients. They gave no indications of the biological effects of wear in the human environment. Lastly, retrieval of failed implants was essential to understanding why failure occurred.These lessons must never be forgotten and must form the basis by which new or altered implants are introduced and how they should be monitored. This will enable safer innovation for patients, surgeons and manufacturers. The problems with MoM hips will not have been in vain.
Collapse
|
34
|
Berber R, Skinner JA, Hart AJ. Management of metal-on-metal hip implant patients: Who, when and how to revise? World J Orthop 2016; 7:272-9. [PMID: 27190754 PMCID: PMC4865716 DOI: 10.5312/wjo.v7.i5.272] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Revised: 01/12/2016] [Accepted: 03/07/2016] [Indexed: 02/06/2023] Open
Abstract
The debate on how best to manage patients with metal-on-metal (MOM) hip implants continues. With over 1 million patients affected worldwide, the impact is far reaching. The majority of the aggressive failures of MOM hip implants have been dealt with by revision hip surgery, leaving patients with a much more indolent pattern of failure of devices that have been in situ for more than 10 years. The longer-term outcome for such patients remains unknown, and much debate exists on how best to manage these patients. Regulatory guidance is available but remains open to interpretation due to the lack of current evidence and long-term studies. Metal ion thresholds for concern have been suggested at 7 ppb for hip resurfacing arthroplasty and below this level for large diameter total hip arthroplasties. Soft tissue changes including pseudotumours and muscle atrophy have been shown to progress, but this is not consistent. New advanced imaging techniques are helping to diagnose complications with metal hips and the reasons for failure, however these are not widely available. This has led to some centres to tackle difficult cases through multidisciplinary collaboration, for both surgical management decisions and also follow-up decisions. We summarise current evidence and consider who is at risk, when revision should be undertaken and how patients should be managed.
Collapse
|
35
|
Bay-Jensen AC, Reker D, Kjelgaard-Petersen CF, Mobasheri A, Karsdal MA, Ladel C, Henrotin Y, Thudium CS. Osteoarthritis year in review 2015: soluble biomarkers and the BIPED criteria. Osteoarthritis Cartilage 2016; 24:9-20. [PMID: 26707988 DOI: 10.1016/j.joca.2015.10.014] [Citation(s) in RCA: 61] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2015] [Revised: 10/16/2015] [Accepted: 10/21/2015] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To review and summarize biomarker data published from April 2014 to May 2015 to provide insight to the ongoing work in the field of osteoarthritis (OA). Furthermore, to summarize the BIPED criteria and set it in context of the medical needs of 2015. METHODS PubMed was used as searching machine: Time period 2014/04/01-2015/05/01, MeSH term [Biomarker] AND [Osteoarthritis], Language; English, Full text available. Reviews were excluded. Only papers describing protein based biomarkers measured in human body fluids from OA patients were included. RESULTS Biomarkers of joint tissue turnover, cytokines, chemokines and peptide arrays were measured in different cohorts and studies. Amongst those were previously tested biomarkers such as osteocalcin, Carboxy-terminal cross-linked fragment of type II collagen (CTX-II) and cartilage oligomeric matrix protein (COMP). A majority of the biomarker were classified as I, B or B biomarkers according to the BIPED criteria. Work is continuing on testing biomarkers in OA. There is still a huge, unmet medical need to identify, test, validate and qualify novel and well-known biomarkers. A pre-requisite for this is better characterization and classification of biomarkers to their needs, which may not be reached before higher understanding of OA phenotypes has been gained. In addition, we provide some references to some recent guidelines from Food and Drug Administration (FDA) and European Medicines Agency (EMA) on qualification and usage of biomarkers for drug development and personalized medicine, which may provide value to the field.
Collapse
Affiliation(s)
- A C Bay-Jensen
- Rheumatology, Biomarkers and Research, Nordic Bioscience, Herlev, Denmark.
| | - D Reker
- Rheumatology, Biomarkers and Research, Nordic Bioscience, Herlev, Denmark
| | | | - A Mobasheri
- Faculty of Health and Medical Sciences, University of Surrey, United Kingdom; Arthritis Research UK Centre for Sport, Exercise and Osteoarthritis, Arthritis Research UK Pain Centre, Medical Research Council and Arthritis Research UK Centre for Musculoskeletal Ageing Research, University of Nottingham, United Kingdom; Center of Excellence in Genomic Medicine Research (CEGMR), King Fahd Medical Research Center (KFMRC), King AbdulAziz University, Jeddah, Saudi Arabia
| | - M A Karsdal
- Rheumatology, Biomarkers and Research, Nordic Bioscience, Herlev, Denmark
| | - C Ladel
- OA Research & Early Clinical Development, Merck KGaA, Darmstadt, Germany
| | - Y Henrotin
- Bone and Cartilage Research Unit, Arthropole Liège, University of Liège, Institute of Pathology, Liège, Belgium
| | - C S Thudium
- Rheumatology, Biomarkers and Research, Nordic Bioscience, Herlev, Denmark
| |
Collapse
|
36
|
Cobalt to Chromium Ratio is Not a Key Marker for Adverse Local Tissue Reaction (ALTR) in Metal on Metal Hips. J Arthroplasty 2015; 30:107-9. [PMID: 26100470 DOI: 10.1016/j.arth.2015.02.049] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Revised: 01/23/2015] [Accepted: 02/11/2015] [Indexed: 02/01/2023] Open
Abstract
The diagnosis of adverse local tissue reaction (ALTR) after metal-on-metal total hip arthroplasty (MoMTHA) presents a significant challenge. No single biomarker is specific for ALTR. The purpose of this study was to determine if the ratio of cobalt to chromium ions is useful for diagnosing ALTR in MoMTHA. In 89 bearing-related revision THAs, preoperative cobalt and chromium ion levels were compared to an intraoperative soft tissue damage grading scale. The average cobalt to chromium ratio was 2.96 (0-20). There was no correlation between the tissue scale and the cobalt to chromium ratio (R=0.095; P=0.41). Many variables affecting ion production/excretion mitigate the use of the ion ratio. The cobalt to chromium ratio is not a predictive biomarker for ALTR in MoMTHA.
Collapse
|
37
|
Donaldson FE, Nyman E, Coburn JC. Prediction of contact mechanics in metal-on-metal Total Hip Replacement for parametrically comprehensive designs and loads. J Biomech 2015; 48:1828-35. [PMID: 25980556 DOI: 10.1016/j.jbiomech.2015.04.037] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2014] [Revised: 04/23/2015] [Accepted: 04/27/2015] [Indexed: 12/19/2022]
Abstract
Manufacturers and investigators of Total Hip Replacement (THR) bearings require tools to predict the contact mechanics resulting from diverse design and loading parameters. This study provides contact mechanics solutions for metal-on-metal (MoM) bearings that encompass the current design space and could aid pre-clinical design optimization and evaluation. Stochastic finite element (FE) simulation was used to calculate the head-on-cup contact mechanics for five thousand combinations of design and loading parameters. FE results were used to train a Random Forest (RF) surrogate model to rapidly predict the contact patch dimensions, contact area, pressures and plastic deformations for arbitrary designs and loading. In addition to widely observed polar and edge contact, FE results included ring-polar, asymmetric-polar, and transitional categories which have previously received limited attention. Combinations of design and load parameters associated with each contact category were identified. Polar contact pressures were predicted in the range of 0-200 MPa with no permanent deformation. Edge loading (with subluxation) was associated with pressures greater than 500 MPa and induced permanent deformation in 83% of cases. Transitional-edge contact (with little subluxation) was associated with intermediate pressures and permanent deformation in most cases, indicating that, even with ideal anatomical alignment, bearings may face extreme wear challenges. Surrogate models were able to accurately predict contact mechanics 18,000 times faster than FE analyses. The developed surrogate models enable rapid prediction of MoM bearing contact mechanics across the most comprehensive range of loading and designs to date, and may be useful to those performing bearing design optimization or evaluation.
Collapse
Affiliation(s)
- Finn E Donaldson
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Office of Medical Products and Tobacco, U.S. Food and Drug Administration, Silver Spring, MD, USA.
| | - Edward Nyman
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Office of Medical Products and Tobacco, U.S. Food and Drug Administration, Silver Spring, MD, USA
| | - James C Coburn
- Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, Office of Medical Products and Tobacco, U.S. Food and Drug Administration, Silver Spring, MD, USA
| |
Collapse
|
38
|
Bosker BH, Ettema HB, van Rossum M, Boomsma MF, Kollen BJ, Maas M, Verheyen CCPM. Pseudotumor formation and serum ions after large head metal-on-metal stemmed total hip replacement. Risk factors, time course and revisions in 706 hips. Arch Orthop Trauma Surg 2015; 135:417-25. [PMID: 25663048 DOI: 10.1007/s00402-015-2165-2] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Indexed: 11/25/2022]
Abstract
INTRODUCTION The incidence and natural course of pseudotumors in metal-on-metal total hip arthroplasties is largely unknown. The objective of this study was to identify the true incidence and risk factors of pseudotumor formation in large head metal-on-metal total hip arthroplasties. MATERIALS AND METHODS Incidence, time course and risk factors for pseudotumor formation were analysed after large femoral head MoM-THA. We defined a pseudotumor as a (semi-)solid or cystic peri-prosthetic soft-tissue mass with a diameter ≥2 cm that could not be attributed to infection, malignancy, bursa or scar tissue. All patients treated in our clinic with MoM-THA's were contacted. CT scan, metal ions and X-rays were obtained. Symptoms were recorded. RESULTS After median follow-up of 3 years, 706 hips were screened in 626 patients. There were 228 pseudotumors (32.3 %) in 219 patients (35.0 %). Pseudotumor formation significantly increased after prolonged follow-up. Seventy-six hips (10.8 %) were revised in 73 patients (11.7 %), independent risk factors were identified. Best cutoff point for cobalt and chromium was 4 μg/l (68 and 77 nmol/l). CONCLUSIONS This study confirms a high incidence of pseudotumors, dramatically increasing after prolonged follow-up. Risk factors for pseudotumors are of limited importance. Pain was the strongest predictor for pseudotumor presence; cobalt chromium and swelling were considered poor predictors. Cross-sectional imaging is the main screening tool during follow-up.
Collapse
Affiliation(s)
- B H Bosker
- , pc Hoofdstraat 13, 8023, AJ, Zwolle, The Netherlands,
| | | | | | | | | | | | | |
Collapse
|
39
|
Tvermoes BE, Paustenbach DJ, Kerger BD, Finley BL, Unice KM. Review of cobalt toxicokinetics following oral dosing: Implications for health risk assessments and metal-on-metal hip implant patients. Crit Rev Toxicol 2015; 45:367-87. [DOI: 10.3109/10408444.2014.985818] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
40
|
Shah KM, Quinn PD, Gartland A, Wilkinson JM. Understanding the tissue effects of tribo-corrosion: uptake, distribution, and speciation of cobalt and chromium in human bone cells. J Orthop Res 2015; 33:114-21. [PMID: 25251692 DOI: 10.1002/jor.22729] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Accepted: 08/08/2014] [Indexed: 02/04/2023]
Abstract
Cobalt and chromium species are released in the local tissues as a result of tribo-corrosion, and affect bone cell survival and function. However we have little understanding of the mechanisms of cellular entry, intracellular distribution, and speciation of the metals that result in impaired bone health. Here we used synchrotron based X-ray fluorescence (XRF), X-ray absorption spectroscopy (XAS), and fluorescent-probing approaches of candidate receptors P2X7R and divalent metal transporter-1 (DMT-1), to better understand the entry, intra-cellular distribution and speciation of cobalt (Co) and chromium (Cr) in human osteoblasts and primary human osteoclasts. We found that both Co and Cr were most highly localized at nuclear and perinuclear sites in osteoblasts, suggesting uptake through cell membrane transporters, and supported by a finding that P2X7 receptor blockade reduced cellular entry of Co. In contrast, metal species were present at discrete sites corresponding to the basolateral membrane in osteoclasts, suggesting cell entry by endocytosis and trafficking through a functional secretory domain. An intracellular reduction of Cr6+ to Cr3+ was the only redox change observed in cells treated with Co2+, Cr3+, and Cr6+. Our data suggest that the cellular uptake and processing of Co and Cr differs between osteoblasts and osteoclasts.
Collapse
Affiliation(s)
- Karan M Shah
- Department of Human Metabolism, The Mellanby Centre for Bone Research, The University of Sheffield, Beech Hill Road, Sheffield, S10 2RX, United Kingdom
| | | | | | | |
Collapse
|
41
|
Furnes O, Paxton E, Cafri G, Graves S, Bordini B, Comfort T, Rivas MC, Banerjee S, Sedrakyan A. Distributed analysis of hip implants using six national and regional registries: comparing metal-on-metal with metal-on-highly cross-linked polyethylene bearings in cementless total hip arthroplasty in young patients. J Bone Joint Surg Am 2014; 96 Suppl 1:25-33. [PMID: 25520416 PMCID: PMC4271426 DOI: 10.2106/jbjs.n.00459] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The regulation of medical devices has attracted controversy recently because of problems related to metal-on-metal hip implants. There is growing evidence that metal-on-metal implants fail early and cause local and systemic complications. However, the failure associated with metal-on-metal head size is not consistently documented and needs to be communicated to patients and surgeons. The purpose of this study is to compare implant survival of metal on metal with that of metal on highly cross-linked polyethylene. METHODS Using a distributed health data network, primary total hip arthroplasties were identified from six national and regional total joint arthroplasty registries (2001 to 2010). Inclusion criteria were patient age of forty-five to sixty-four years, cementless total hip arthroplasties, primary osteoarthritis diagnosis, and exclusion of the well-known outlier implant ASR (articular surface replacement). The primary outcome was revision for any reason. A meta-analysis of survival probabilities was performed with use of a fixed-effects model. Metal-on-metal implants with a large head size of >36 mm were compared with metal-on-highly cross-linked polyethylene implants. RESULTS Metal-on-metal implants with a large head size of >36 mm were used in 5172 hips and metal-on-highly cross-linked polyethylene implants were used in 14,372 hips. Metal-on-metal total hip replacements with a large head size of >36 mm had an increased risk of revision compared with metal-on-highly cross-linked polyethylene total hip replacements with more than two years of follow-up, with no difference during the first two years after implantation. The results of the hazard ratios (and 95% confidence intervals) from the multivariable model at various durations of follow-up were 0.95 (0.74 to 1.23) at zero to two years (p = 0.698), 1.42 (1.16 to 1.75) at more than two years to four years (p = 0.001), 1.78 (1.45 to 2.19) at more than four years to six years (p < 0.001), and 2.15 (1.63 to 2.83) at more than six years to seven years (p < 0.001). CONCLUSIONS We conducted a comparison of large-head-size, metal-on-metal implants and metal-on-highly cross-linked polyethylene implants in younger patients with uncemented fixation. We found consistent and strong evidence worldwide that large-head-size, metal-on-metal implants were associated with increased risk of revision after two years compared with metal-on-highly cross-linked polyethylene implants, with the effect becoming more pronounced over time.
Collapse
Affiliation(s)
- Ove Furnes
- The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Haukeland University Hospital, Mollendalsbakken 11, N-5021 Bergen, Norway
| | - Elizabeth Paxton
- Surgical Outcomes & Analysis Department, Kaiser Permanente, 8954 Rio San Diego Drive, Suite 406, San Diego, CA 92108
| | - Guy Cafri
- Surgical Outcomes & Analysis Department, Kaiser Permanente, 8954 Rio San Diego Drive, Suite 406, San Diego, CA 92108
| | - Stephen Graves
- Australia Orthopaedic Association National Joint Replacement Registry, Discipline of Public Health, MDP DX 650 511, University of Adelaide, Adelaide, SA 5005, Australia
| | - Barbara Bordini
- Register of the Orthopaedic Prosthetic Implants (R.I.P.O. [Registro dell’implantologia Protesica Ortopedica]), c/o Medical Technology Laboratory, Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
| | - Thomas Comfort
- HealthEast Joint Registry, 1690 University Avenue West, Data Science, Suite 400, Minneapolis, MN 55104
| | - Moises Coll Rivas
- Consorci Sanitari del Maresme, Hospital de Mataro, Carretera de Cirera s/n, 08304 Mataro (Barcelona), Catalonia, Spain
| | - Samprit Banerjee
- Weill Cornell Medical College, 402 East 67th Street, New York, NY 10065
| | - Art Sedrakyan
- Weill Cornell Medical College, 402 East 67th Street, New York, NY 10065
| |
Collapse
|
42
|
Smeekes C, Ongkiehong B, van der Wal B, Wolterbeek R, Henseler JF, Nelissen R. Large fixed-size metal-on-metal total hip arthroplasty: higher serum metal ion levels in patients with pain. INTERNATIONAL ORTHOPAEDICS 2014; 39:631-8. [PMID: 25472752 DOI: 10.1007/s00264-014-2605-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Accepted: 11/12/2014] [Indexed: 01/30/2023]
Abstract
PURPOSE Recently, concerns have arisen about metal-on-metal (MoM) total hip arthroplasty (THA). Therefore, the purpose of this cross-sectional cohort study was to describe the incidence of pain, pseudotumours, revisions and the relation between elevated metal ion levels, functional outcome and quality of life after MoM THA. METHODS In 351 patients, 377 MoM THA with a fixed-size 38-mm head were evaluated with a mean follow-up of 30 months (range 11-58). Evaluation included pain, serum metal ions, patient-reported questionnaires (Short Form-36 [SF-36], Hip disability and Osteoarthritis Outcome Score [HOOS] and the Oxford Hip Score [OHS]) and radiological imaging. Sixteen patients did not participate in the screening. RESULTS One hundred and eighteen (35 %) patients reported pain and showed significantly higher cobalt and chromium levels compared to patients without pain. Median serum cobalt levels were 4.4 μg/l (interquartile range [IQR] 6.6) and chromium levels were 3.6 μg/l (IQR 4.8). Patients with cobalt levels of ≤5 μg/l reported significantly better outcome on the SF-36 and HOOS. Fifty-seven pseudotumours were identified in 227 THAs. A revision rate of 19 % was observed. CONCLUSIONS In conclusion, 35 % of the patients experienced pain after MoM THA. These patients showed significantly higher serum metal ion levels. The patient-reported questionnaires indicated significantly better outcome in patients with cobalt levels ≤5 μg/l.
Collapse
Affiliation(s)
- Christiaan Smeekes
- Department of Orthopaedics, Leiden University Medical Centre, Leiden, The Netherlands,
| | | | | | | | | | | |
Collapse
|
43
|
Lawrence H, Deehan D, Holland J, Kirby J, Tyson-Capper A. The immunobiology of cobalt: demonstration of a potential aetiology for inflammatory pseudotumours after metal-on-metal replacement of the hip. Bone Joint J 2014; 96-B:1172-7. [PMID: 25183586 DOI: 10.1302/0301-620x.96b9.33476] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Abnormal wear of cobalt-containing metal-on-metal joints is associated with inflammatory pseudotumours. Cobalt ions activate human toll-like receptor 4 (TLR4), which normally responds to bacterial lipopolysaccharide (LPS) in sepsis. Activation of TLR4 by LPS increases the expression of chemokines IL-8 and CXCL10, which recruit leukocytes and activated T-cells, respectively. This study was designed to determine whether cobalt induces a similar inflammatory response to LPS by promoting the expression of IL-8 and CXCL10. A human monocytic cell line, derived from acute monocytic leukaemia, was treated with cobalt ions and expression of IL-8 and CXCL10 measured at mRNA and protein levels. Cobalt-treated macrophages showed a 60-fold increase in IL-8 mRNA, and an eightfold increase in production of the mature chemokine (both p < 0.001); expression of the CXCL10 gene and protein was also significantly increased by cobalt (both p < 0.001). Experiments were also performed in the presence of CLI-095, a TLR4-specific antagonist which abrogated the cobalt-mediated increase in IL-8 and CXCL10 expression. These findings suggest that cobalt ions induce inflammation similar to that observed during sepsis by the simultaneous activation of two TLR4-mediated signalling pathways. These pathways result in increased production of IL-8 and CXCL10, and may be implicated in pseudotumour formation following metal-on-metal replacement.
Collapse
Affiliation(s)
- H Lawrence
- Newcastle University, Institute of Cellular Medicine, 3rd Floor, William Leech Building, Faculty of Medical Sciences, Framlington Place, Newcastle upon Tyne, NE2 4HH, UK
| | - D Deehan
- Freeman Hospital, Department of Orthopaedics, Freeman Hospital, Freeman Road, Newcastle upon Tyne, NE7 7DN, UK
| | - J Holland
- Freeman Hospital, Department of Orthopaedics, Freeman Hospital, Freeman Road, Newcastle upon Tyne, NE7 7DN, UK
| | - J Kirby
- Newcastle University, Institute of Cellular Medicine, 3rd Floor, William Leech Building, Faculty of Medical Sciences, Framlington Place, Newcastle upon Tyne, NE2 4HH, UK
| | - A Tyson-Capper
- Newcastle University, Institute of Cellular Medicine, 3rd Floor, William Leech Building, Faculty of Medical Sciences, Framlington Place, Newcastle upon Tyne, NE2 4HH, UK
| |
Collapse
|
44
|
Stiehler M, Zobel F, Hannemann F, Schmitt J, Lützner J, Kirschner S, Günther KP, Hartmann A. [Complications of metal-on-metal tribological pairing]. DER ORTHOPADE 2014; 43:79-91. [PMID: 24356820 DOI: 10.1007/s00132-013-2131-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Metal-on-metal (MoM) tribological pairing results in less volumetric abrasion than pairing with the conventionally used polyethylene and is associated with a lower risk of material failure compared to other hard-hard pairings. An increased frequency of problem cases in recent years has led to a great increase in uncertainty. Against this background in this article the current aspects of epidemiology, etiology, diagnostics and treatment of complications in MoM hip joint endoprostheses will be discussed. EPIDEMIOLOGY AND ETIOLOGY Based on the results from national endoprosthesis registers and selected clinical studies an evaluation of the rate of local complications from MoM tribological pairings was undertaken. A differentiation was made between MoM pairings in pedicled small head prostheses (≤ 32 mm), large head (> 32 mm) and surface replacement (OFE) endoprostheses. Each year MoM endoprostheses release on average 10(12)-10(14) cobalt (Co) and chromium (Cr) nanoparticles per patient. This release of metal ions and particles can lead to a variety of tissue reactions. DIAGNOSTICS A differentiation must be made between regular routine diagnostics within the framework of implant follow-up screening and specific investigations due to the occurrence of complaints. The diagnostics for patients treated with MoM hip endoprostheses consists of a standardized step-wise approach considering possible differential diagnoses and the utilization of modern laboratory chemical and radiological methods. When problems occur, a differentiation should preferentially be made between complaints not caused by metal and mechanical problems (e.g. prosthesis loosening and impingement) and symptoms due to periprosthetic infections. THERAPY OF COMPLICATIONS The normal standards for hip endoprosthetics are also valid for periprosthetic infections, fractures and other general complications. Specific measures are, however, necessary for complications due to metal-specific risks.
Collapse
Affiliation(s)
- M Stiehler
- UniversitätsCentrum für Orthopädie und Unfallchirurgie, Klinik für Orthopädie, Universitätsklinikum Carl Gustav Carus, TU Dresden, Fetscherstr. 74, 01307, Dresden, Deutschland
| | | | | | | | | | | | | | | |
Collapse
|
45
|
Abstract
INTRODUCTION One in eight of all total hip replacements requires revision within 10 years, 60% because of wear-related complications. The bearing surfaces may be made of cobalt/chromium, stainless steel, ceramic, or polyethylene. Friction between bearing surfaces and corrosion of non-moving parts can result in increased local and systemic metal concentrations. OBJECTIVES To identify and systematically review published reports of systemic toxicity attributed to metal released from hip implants and to propose criteria for the assessment of these patients. METHODS Medline (from 1950) and Embase (from 1980) were searched to 28 February 2014 using the search terms (text/abstract) chrom* or cobalt* and [toxic* or intox* or poison* or adverse effect or complication] and [prosthes* or 'joint replacement' or hip or arthroplast*] and PubMed (all available years) was searched using the search term (("Chromium/adverse effects"[Mesh] OR "Chromium/poisoning"[Mesh] OR "Chromium/toxicity"[Mesh]) OR ("Cobalt/adverse effects"[Mesh] OR "Cobalt/poisoning"[Mesh] OR "Cobalt/toxicity"[Mesh])) AND ("Arthroplasty, Replacement, Hip"[Mesh] OR "Hip Prosthesis"[Mesh]). These searches identified 281 unique references, of which 23 contained original case data. Three further reports were identified from the bibliographies of these papers. As some cases were reported repeatedly the 26 papers described only 18 individual cases. Systemic toxicity. Ten of these eighteen patients had undergone revision from a ceramic-containing bearing to one containing a metal component. The other eight had metal-on-metal prostheses. Systemic toxicity was first manifest months and often several years after placement of the metal-containing joint. The reported systemic features fell into three main categories: neuro-ocular toxicity (14 patients), cardiotoxicity (11 patients) and thyroid toxicity (9 patients). Neurotoxicity was manifest as peripheral neuropathy (8 cases), sensorineural hearing loss (7) and cognitive decline (5); ocular toxicity presented as visual impairment (6). All these neurological features, except cognitive decline, have been associated with cobalt poisoning previously. Type of prosthesis and blood metal concentrations. Where blood or serum metal concentrations were reported (n = 17 for cobalt and n = 14 for chromium), the median cobalt concentration was 398 (range, 13.6-6521) μg/L and the median chromium concentration was 48 μg/L (in whole blood) (range, 4.1-221 μg/L including serum and blood values). Those patients reported to have systemic features who had received a metal-on-metal prosthesis (n = 8) had a median peak blood cobalt concentration of 34.5 (range, 13.6-398.6) μg/L; those with a metal-containing revision of a failed ceramic prosthesis (n = 10) had a median blood cobalt concentration of 506 (range, 353-6521) μg/L. Management. The most common treatment was removal of the metal-containing prosthesis, undertaken in all but 2 patients. This was usually associated with a fall in circulating cobalt concentration and improvement in some or all features. Clinical and toxicological assessment of systemic features. We propose the following criteria for assessing the likelihood that clinical features are related to cobalt toxicity: clinical effects consistent with the known neurological, cardiac, or thyroidal effects of cobalt, and for which any other explanation is less likely; increased blood cobalt concentrations (substantially higher than those in patients with well-functioning prostheses) several months after hip replacement; a fall in the blood cobalt concentration, usually accompanied by signs of improvement in features. When judged by these criteria, the systemic features in 10 of the reported cases are likely to be related to cobalt exposure from a metal-containing hip prosthesis. CONCLUSIONS Rarely, patients exposed to high circulating concentrations of cobalt from failed hip replacements develop neurological damage, hypothyroidism and/or cardiomyopathy, which may not resolve completely even after removal of the prosthesis. The greatest risk of systemic cobalt toxicity seems to result from accelerated wear of a cobalt-containing revision of a failed ceramic prosthesis, rather than from primary failure of a metal-on-metal prosthesis.
Collapse
Affiliation(s)
- S M Bradberry
- West Midlands Poisons Unit, City Hospital , Birmingham , UK
| | | | | |
Collapse
|
46
|
Leopold SS. Editorial: When "safe and effective" becomes dangerous. Clin Orthop Relat Res 2014; 472:1999-2001. [PMID: 24844886 PMCID: PMC4048394 DOI: 10.1007/s11999-014-3675-x] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2014] [Accepted: 04/29/2014] [Indexed: 01/31/2023]
Affiliation(s)
- Seth S Leopold
- Clinical Orthopaedics and Related Research, Philadelphia, PA, 19103, USA,
| |
Collapse
|
47
|
Clark MJ, Prentice JR, Hoggard N, Paley MN, Hadjivassiliou M, Wilkinson JM. Brain structure and function in patients after metal-on-metal hip resurfacing. AJNR Am J Neuroradiol 2014; 35:1753-8. [PMID: 24722312 DOI: 10.3174/ajnr.a3922] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
BACKGROUND AND PURPOSE Hip prostheses that use a metal-on-metal articulation expose the brain to elevated metal concentrations that, in acute excess due to prosthesis malfunction, is associated with neurologic damage, including visual and hearing loss and motor deficits. Here, we examined whether chronic exposure to lower elevated metal levels, typical of well-functioning prostheses, also affects brain structure and function. MATERIALS AND METHODS We compared brain volumes, metal deposition, and gray matter attenuation by MR imaging and clinical neurologic function in patients 8 years after receiving a metal-on-metal hip resurfacing versus a matched group of patients with the same duration exposure to a conventional hip prosthesis. RESULTS Twenty-nine patients (25 men; mean, age 59±7 years) after metal-on-metal hip resurfacing and 29 patients (25 men; 59±8 years) after total hip arthroplasty were compared. Whole blood cobalt and chromium concentrations were 5-10 times higher in the metal-on-metal hip resurfacing group (P<.0001). Occipital cortex gray matter attenuation tended to be lower (P<.005 uncorrected, P>.05 corrected), and the optic chiasm area tended to be lower (mean difference, -2.7 mm2; P=.076) in the metal-on-metal hip resurfacing group. Subgroup analyses in 34 patients (17 per group), after exclusion of primary ocular pathology, showed the same trend in gray matter attenuation in the occipital cortex and basal ganglia and a smaller optic chiasm in the metal-on-metal hip resurfacing group (mean difference, -3.9 mm2; P=.048). No other structural or functional differences were found between the groups. CONCLUSIONS Chronic exposure to metal-on-metal hip resurfacing is associated with subtle structural change in the visual pathways and the basal ganglia in asymptomatic patients.
Collapse
Affiliation(s)
- M J Clark
- From the Departments of Human Metabolism (M.J.C., J.R.P., J.M.W.)
| | - J R Prentice
- From the Departments of Human Metabolism (M.J.C., J.R.P., J.M.W.)
| | - N Hoggard
- Cardiovascular Science (N.H., M.N.P.), University of Sheffield, The Medical School, Sheffield, United Kingdom
| | - M N Paley
- Cardiovascular Science (N.H., M.N.P.), University of Sheffield, The Medical School, Sheffield, United Kingdom
| | - M Hadjivassiliou
- Department of Neurology (M.H.), Sheffield Teaching Hospitals National Health Service Foundation Trust, Royal Hallamshire Hospital, Sheffield, United Kingdom
| | - J M Wilkinson
- From the Departments of Human Metabolism (M.J.C., J.R.P., J.M.W.) Department of Orthopaedics (J.M.W.), Sheffield Teaching Hospitals National Health Service Foundation Trust, Northern General Hospital, Sheffield, United Kingdom.
| |
Collapse
|
48
|
Auditory and visual health after ten years of exposure to metal-on-metal hip prostheses: a cross-sectional study follow up. PLoS One 2014; 9:e90838. [PMID: 24621561 PMCID: PMC3951221 DOI: 10.1371/journal.pone.0090838] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2013] [Accepted: 01/27/2014] [Indexed: 11/19/2022] Open
Abstract
Case reports of patients with mal-functioning metal-on-metal hip replacement (MoMHR) prostheses suggest an association of elevated circulating metal levels with visual and auditory dysfunction. However, it is unknown if this is a cumulative exposure effect and the impact of prolonged low level exposure, relevant to the majority of patients with a well-functioning prosthesis, has not been studied. Twenty four male patients with a well-functioning MoMHR and an age and time since surgery matched group of 24 male patients with conventional total hip arthroplasty (THA) underwent clinical and electrophysiological assessment of their visual and auditory health at a mean of ten years after surgery. Median circulating cobalt and chromium concentrations were higher in patients after MoMHR versus those with THA (P<0.0001), but were within the Medicines and Healthcare Products Regulatory Agency (UK) investigation threshold. Subjective auditory tests including pure tone audiometric and speech discrimination findings were similar between groups (P>0.05). Objective assessments, including amplitude and signal-to-noise ratio of transient evoked and distortion product oto-acoustic emissions (TEOAE and DPOAE, respectively), were similar for all the frequencies tested (P>0.05). Auditory brainstem responses (ABR) and cortical evoked response audiometry (ACR) were also similar between groups (P>0.05). Ophthalmological evaluations, including self-reported visual function by visual functioning questionnaire, as well as binocular low contrast visual acuity and colour vision were similar between groups (P>0.05). Retinal nerve fibre layer thickness and macular volume measured by optical coherence tomography were also similar between groups (P>0.05). In the presence of moderately elevated metal levels associated with well-functioning implants, MoMHR exposure does not associate with clinically demonstrable visual or auditory dysfunction.
Collapse
|
49
|
Paustenbach DJ, Galbraith DA, Finley BL. Interpreting cobalt blood concentrations in hip implant patients. Clin Toxicol (Phila) 2013; 52:98-112. [DOI: 10.3109/15563650.2013.857024] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|