1
|
Micheletti C, Shah FA. Bone hierarchical organization through the lens of materials science: Present opportunities and future challenges. Bone Rep 2024; 22:101783. [PMID: 39100913 PMCID: PMC11295937 DOI: 10.1016/j.bonr.2024.101783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 06/20/2024] [Accepted: 06/22/2024] [Indexed: 08/06/2024] Open
Abstract
Multiscale characterization is essential to better understand the hierarchical architecture of bone and an array of analytical methods contributes to exploring the various structural and compositional aspects. Incorporating X-ray tomography, X-ray scattering, vibrational spectroscopy, and atom probe tomography alongside electron microscopy provides a comprehensive approach, offering insights into the diverse levels of organization within bone. X-ray scattering techniques reveal information about collagen-mineral spatial relationships, while X-ray tomography captures 3D structural details, especially at the microscale. Electron microscopy, such as scanning and transmission electron microscopy, extends resolution to the nanoscale, showcasing intricate features such as collagen fibril organization. Additionally, atom probe tomography achieves sub-nanoscale resolution and high chemical sensitivity, enabling detailed examination of bone composition. Despite various technical challenges, a correlative approach allows for a comprehensive understanding of bone material properties. Real-time investigations through in situ and in operando approaches shed light on the dynamic processes in bone. Recently developed techniques such as liquid, in situ transmission electron microscopy provide insights into calcium phosphate formation and collagen mineralization. Mechanical models developed in the effort to link structure, composition, and function currently remain oversimplified but can be improved. In conclusion, correlative analytical platforms provide a holistic perspective of bone extracellular matrix and are essential for unraveling the intricate interplay between structure and composition within bone.
Collapse
Affiliation(s)
- Chiara Micheletti
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Furqan A. Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
2
|
Micheletti C, DiCecco LA, Deering J, Chen W, Ervolino da Silva AC, Shah FA, Palmquist A, Okamoto R, Grandfield K. Mesoscale characterization of osseointegration around an additively manufactured genistein-coated implant. Sci Rep 2024; 14:15339. [PMID: 38961115 PMCID: PMC11222380 DOI: 10.1038/s41598-024-66058-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2023] [Accepted: 06/26/2024] [Indexed: 07/05/2024] Open
Abstract
Given the hierarchical nature of bone and bone interfaces, osseointegration, namely the formation of a direct bone-implant contact, is best evaluated using a multiscale approach. However, a trade-off exists between field of view and spatial resolution, making it challenging to image large volumes with high resolution. In this study, we combine established electron microscopy techniques to probe bone-implant interfaces at the microscale and nanoscale with plasma focused ion beam-scanning electron microscopy (PFIB-SEM) tomography to evaluate osseointegration at the mesoscale. This characterization workflow is demonstrated for bone response to an additively manufactured Ti-6Al-4V implant which combines engineered porosity to facilitate bone ingrowth and surface functionalization via genistein, a phytoestrogen, to counteract bone loss in osteoporosis. SEM demonstrated new bone formation at the implant site, including in the internal implant pores. At the nanoscale, scanning transmission electron microscopy and energy-dispersive X-ray spectroscopy confirmed the gradual nature of the bone-implant interface. By leveraging mesoscale analysis with PFIB-SEM tomography that captures large volumes of bone-implant interface with nearly nanoscale resolution, the presence of mineral ellipsoids varying in size and orientation was revealed. In addition, a well-developed lacuno-canalicular network and mineralization fronts directed both towards the implant and away from it were highlighted.
Collapse
Affiliation(s)
- Chiara Micheletti
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada.
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Liza-Anastasia DiCecco
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Joseph Deering
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | - Wanqi Chen
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada
| | | | - Furqan A Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Roberta Okamoto
- Department of Basic Sciences, Araçatuba Dental School, São Paulo State University, Araçatuba, SP, Brazil
- Research Productivity Scholarship (Process: 309408/2020-2), Araçatuba, SP, Brazil
| | - Kathryn Grandfield
- Department of Materials Science and Engineering, McMaster University, Hamilton, ON, Canada.
- School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada.
- Brockhouse Institute for Materials Research, McMaster University, Hamilton, ON, Canada.
| |
Collapse
|
3
|
Bezdjian A, Mikolajewicz N, Denton C, Bouchard A, Rummler M, Gludovatz B, Shin M, Zimmermann E, Salameh S, Daniel SJ, Willie BM. Resonance Frequency Analysis Identifies Implant- and Host-Related Factors Associated With Bone-Anchored Hearing Implant Stability. Otol Neurotol 2024; 45:676-683. [PMID: 38865727 DOI: 10.1097/mao.0000000000004213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
HYPOTHESIS Resonance frequency analysis (RFA) is a reliable, noninvasive method to assess the stability of bone-anchored hearing implants (BAHIs), although surgical-, implant-, and host-related factors can affect its outcome. BACKGROUND BAHI plays an important role in restoring hearing function. However, implant- and host-related factors contribute to premature implant extrusion. To mitigate this, noninvasive methods to assess implant stability, along with a better understanding of factors contributing to BAHI failure, are needed. METHODS We evaluated the utility of RFA to quantify implant stability in sawbone (bone mimicking material), 29 human cadaveric samples, and a prospective cohort of 29 pediatric and 27 adult participants, and identified factors associated with implant stability. To validate the use of RFA in BAHI, we compared RFA-derived implant stability quotient (ISQ) estimates to peak loads obtained from mechanical push-out testing. RESULTS ISQ and peak loads were significantly correlated (Spearman rho = 0.48, p = 0.0088), and ISQ reliably predicted peak load up to 1 kN. We then showed that in cadaveric samples, abutment length, internal table bone volume, and donor age were significantly associated with implant stability. We validated findings in our prospective patient cohort and showed that minimally invasive Ponto surgery (MIPS; versus linear incision), longer implantation durations (>16 wk), older age (>25 yr), and shorter abutment lengths (≤10 mm) were associated with better implant stability. Finally, we characterized the short-term reproducibility of ISQ measurements in sawbone and patient implants. CONCLUSIONS Together, our findings support the use of ISQ as a measure of implant stability and emphasize important considerations that impact implant stability, including surgical method, implant duration, age, and abutment lengths.
Collapse
Affiliation(s)
| | | | | | | | | | - Bernd Gludovatz
- School of Mechanical and Manufacturing Engineering, University of New South Wales Sydney, Australia
| | - Mihee Shin
- School of Mechanical and Manufacturing Engineering, University of New South Wales Sydney, Australia
| | | | | | | | | |
Collapse
|
4
|
Shrivas S, Samaur H, Yadav V, Boda SK. Soft and Hard Tissue Integration around Percutaneous Bone-Anchored Titanium Prostheses: Toward Achieving Holistic Biointegration. ACS Biomater Sci Eng 2024; 10:1966-1987. [PMID: 38530973 DOI: 10.1021/acsbiomaterials.3c01555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/28/2024]
Abstract
A holistic biointegration of percutaneous bone-anchored metallic prostheses with both hard and soft tissues dictates their longevity in the human body. While titanium (Ti) has nearly solved osseointegration, soft tissue integration of percutaneous metallic prostheses is a perennial problem. Unlike the firm soft tissue sealing in biological percutaneous structures (fingernails and teeth), foreign body response of the skin to titanium (Ti) leads to inflammation, epidermal downgrowth and inferior peri-implant soft tissue sealing. This review discusses various implant surface treatments/texturing and coatings for osseointegration, soft tissue integration, and against bacterial attachment. While surface microroughness by SLA (sandblasting with large grit and acid etched) and porous calcium phosphate (CaP) coatings improve Ti osseointegration, smooth and textured titania nanopores, nanotubes, microgrooves, and biomolecular coatings encourage soft tissue attachment. However, the inferior peri-implant soft tissue sealing compared to natural teeth can lead to peri-implantitis. Toward this end, the application of smart multifunctional bioadhesives with strong adhesion to soft tissues, mechanical resilience, durability, antibacterial, and immunomodulatory properties for soft tissue attachment to metallic prostheses is proposed.
Collapse
Affiliation(s)
- Sangeeta Shrivas
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore 453552, India
| | - Harshita Samaur
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore 453552, India
| | - Vinod Yadav
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore 453552, India
| | - Sunil Kumar Boda
- Department of Biosciences and Biomedical Engineering, Indian Institute of Technology Indore, Khandwa Road, Simrol, Indore 453552, India
| |
Collapse
|
5
|
Saini P, Sood S, Chahal GS, Jain A. Evaluation of bone apposition on surface modified titanium implant in experimental animal model: A systematic review and meta-analysis. J Indian Soc Periodontol 2024; 28:43-74. [PMID: 38988952 PMCID: PMC11232795 DOI: 10.4103/jisp.jisp_222_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2022] [Revised: 11/20/2022] [Accepted: 11/27/2022] [Indexed: 07/12/2024] Open
Abstract
Purpose To evaluate the response of peri-implant bone to smooth (machined) surface and surface-modified dental implants in healthy experimental animal models. Materials and Methods Systematic electronic search was done for using PUBMED, SCOPUS, WEB OF SCIENCE, and EMBASE databases for potentially relevant records from the last 20 years. Duplicate screening and data extraction were performed to formulate the evidence tables and meta-analysis following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The outcome criteria were: 1. Bone Implant Contact (BIC) in percentage, 2. Removal Torque Values (RTV) in Ncm, 3. Implant stability Quotient (ISQ), Quality assessment was done using the ARRIVE (Animal Research: Reporting of In Vivo Experiments) guidelines and SYRCLE RoB (Systematic Review Centre for Laboratory Animal Experimentation Risk of Bias) tool. Results Results were expressed as pooled mean difference for the respective groups viz. sandblasted and acid etched, laser modified, acid etched and anodized surface. The surface modified implants revealed somewhat higher BIC over machined surface (P < 0.01). Forest plot were drawn for all the outcome variables. Conclusions Within the limitations of this study, the authors found a higher degree of osseointegration pertaining to bone to implant interface, RTV, and implant stability quotient (ISQ) with surface modified procedures which seemed to promote bone formation around peri-implant tissue during the early stages of healing. After analyzing all 37 included publications for the outcome of interest (BIC%, RTV, ISQ), a positive outcome was obtained for both subtractive and additive implant surface modifying procedures over machined implant surfaces when the data were pooled together. More advanced research work on healthy animal models needs to be investigated to review the impact of surface modifications on dental implant osseointegration.
Collapse
Affiliation(s)
- Priya Saini
- Department of Periodontology, Dr. Harvansh Singh Judge Institute of Dental Sciences and Hospital, Panjab University, Chandigarh, India
| | - Shaveta Sood
- Department of Periodontology, Dr. Harvansh Singh Judge Institute of Dental Sciences and Hospital, Panjab University, Chandigarh, India
| | - Gurparkash Singh Chahal
- Department of Periodontology, Dr. Harvansh Singh Judge Institute of Dental Sciences and Hospital, Panjab University, Chandigarh, India
| | - Ashish Jain
- Dental Institute, Ranchi Institute of Medical Sciences, Ranchi, Jharkhand, India
| |
Collapse
|
6
|
Jolic M, Ruscsák K, Emanuelsson L, Norlindh B, Thomsen P, Shah FA, Palmquist A. Leptin receptor gene deficiency minimally affects osseointegration in rats. Sci Rep 2023; 13:15631. [PMID: 37730735 PMCID: PMC10511412 DOI: 10.1038/s41598-023-42379-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 09/09/2023] [Indexed: 09/22/2023] Open
Abstract
Metabolic syndrome represents a cluster of conditions such as obesity, hyperglycaemia, dyslipidaemia, and hypertension that can lead to type 2 diabetes mellitus and/or cardiovascular disease. Here, we investigated the influence of obesity and hyperglycaemia on osseointegration using a novel, leptin receptor-deficient animal model, the Lund MetS rat. Machined titanium implants were installed in the tibias of animals with normal leptin receptor (LepR+/+) and those harbouring congenic leptin receptor deficiency (LepR-/-) and were left to heal for 28 days. Extensive evaluation of osseointegration was performed using removal torque measurements, X-ray micro-computed tomography, quantitative backscattered electron imaging, Raman spectroscopy, gene expression analysis, qualitative histology, and histomorphometry. Here, we found comparable osseointegration potential at 28 days following implant placement in LepR-/- and LepR+/+ rats. However, the low bone volume within the implant threads, higher bone-to-implant contact, and comparable biomechanical stability of the implants point towards changed bone formation and/or remodelling in LepR-/- rats. These findings are corroborated by differences in the carbonate-to-phosphate ratio of native bone measured using Raman spectroscopy. Observations of hypermineralised cartilage islands and increased mineralisation heterogeneity in native bone confirm the delayed skeletal development of LepR-/- rats. Gene expression analyses reveal comparable patterns between LepR-/- and LepR+/+ animals, suggesting that peri-implant bone has reached equilibrium in healing and/or remodelling between the animal groups.
Collapse
Affiliation(s)
- Martina Jolic
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Krisztina Ruscsák
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Lena Emanuelsson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Birgitta Norlindh
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden.
| |
Collapse
|
7
|
Sato M, Shah FA. Contributions of Resin Cast Etching to Visualising the Osteocyte Lacuno-Canalicular Network Architecture in Bone Biology and Tissue Engineering. Calcif Tissue Int 2023; 112:525-542. [PMID: 36611094 PMCID: PMC10106349 DOI: 10.1007/s00223-022-01058-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Accepted: 12/21/2022] [Indexed: 01/09/2023]
Abstract
Recent years have witnessed an evolution of imaging technologies towards sophisticated approaches for visualising cells within their natural environment(s) and for investigating their interactions with other cells, with adjacent anatomical structures, and with implanted biomaterials. Resin cast etching (RCE) is an uncomplicated technique involving sequential acid etching and alkali digestion of resin embedded bone to observe the osteocyte lacuno-canalicular network using scanning electron microscopy. This review summarises the applicability of RCE to bone and the bone-implant interface. Quantitative parameters such as osteocyte size, osteocyte density, and number of canaliculi per osteocyte, and qualitative metrics including osteocyte shape, disturbances in the arrangement of osteocytes and canaliculi, and physical communication between osteocytes and implant surfaces can be investigated. Ageing, osteoporosis, long-term immobilisation, spinal cord injury, osteoarthritis, irradiation, and chronic kidney disease have been shown to impact osteocyte lacuno-canalicular network morphology. In addition to titanium, calcium phosphates, and bioactive glass, observation of direct connectivity between osteocytes and cobalt chromium provides new insights into the osseointegration potential of materials conventionally viewed as non-osseointegrating. Other applications include in vivo and in vitro testing of polymer-based tissue engineering scaffolds and tissue-engineered ossicles, validation of ectopic osteochondral defect models, ex vivo organ culture of whole bones, and observing the effects of gene dysfunction/deletion on the osteocyte lacuno-canalicular network. Without additional contrast staining, any resin embedded specimen (including clinical biopsies) can be used for RCE. The multitude of applications described here attest to the versatility of RCE for routine use within correlative analytical workflows, particularly in biomaterials science.
Collapse
Affiliation(s)
- Mari Sato
- Oral Biochemistry and Molecular Biology, Graduate School of Dental Medicine, Hokkaido University, Sapporo, Japan
| | - Furqan A Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
8
|
Veiko V, Karlagina Y, Zernitckaia E, Egorova E, Radaev M, Yaremenko A, Chernenko G, Romanov V, Shchedrina N, Ivanova E, Chichkov B, Odintsova G. Laser-Induced µ-Rooms for Osteocytes on Implant Surface: An In Vivo Study. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:4229. [PMID: 36500852 PMCID: PMC9737095 DOI: 10.3390/nano12234229] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 11/21/2022] [Accepted: 11/25/2022] [Indexed: 06/17/2023]
Abstract
Laser processing of dental implant surfaces is becoming a more widespread replacement for classical techniques due to its undeniable advantages, including control of oxide formation and structure and surface relief at the microscale. Thus, using a laser, we created several biomimetic topographies of various shapes on the surface of titanium screw-shaped implants to research their success and survival rates. A distinctive feature of the topographies is the presence of "µ-rooms", which are special spaces created by the depressions and elevations and are analogous to the µ-sized room in which the osteocyte will potentially live. We conducted the comparable in vivo study using dental implants with continuous (G-topography with µ-canals), discrete (S-topography with μ-cavities), and irregular (I-topography) laser-induced topographies. A histological analysis performed with the statistical method (with p-value less than 0.05) was conducted, which showed that G-topography had the highest BIC parameter and contained the highest number of mature osteocytes, indicating the best secondary stability and osseointegration.
Collapse
Affiliation(s)
- Vadim Veiko
- Institute of Laser Technologies, ITMO University, Saint-Petersburg 197101, Russia
| | - Yuliya Karlagina
- Institute of Laser Technologies, ITMO University, Saint-Petersburg 197101, Russia
| | - Ekaterina Zernitckaia
- Department of Dental Surgery and Maxillofacial Surgery, Pavlov First Saint-Petersburg State Medical University, Saint-Petersburg 197022, Russia
| | - Elena Egorova
- Institute of Laser Technologies, ITMO University, Saint-Petersburg 197101, Russia
| | - Maxim Radaev
- Institute of Laser Technologies, ITMO University, Saint-Petersburg 197101, Russia
| | - Andrey Yaremenko
- Department of Dental Surgery and Maxillofacial Surgery, Pavlov First Saint-Petersburg State Medical University, Saint-Petersburg 197022, Russia
| | - Gennadiy Chernenko
- Lenmiriot Dental Implant Prosthetics Manufacture, Saint-Petersburg 193079, Russia
| | - Valery Romanov
- Institute of Laser Technologies, ITMO University, Saint-Petersburg 197101, Russia
| | - Nadezhda Shchedrina
- Institute of Laser Technologies, ITMO University, Saint-Petersburg 197101, Russia
| | - Elena Ivanova
- STEM, School of Science, RMIT University, Melbourne 3000, Australia
| | - Boris Chichkov
- Institute of Quantum Optics, Leibniz University of Hanover, 30167 Hannover, Germany
| | - Galina Odintsova
- Institute of Laser Technologies, ITMO University, Saint-Petersburg 197101, Russia
| |
Collapse
|
9
|
Walter N, Stich T, Docheva D, Alt V, Rupp M. Evolution of implants and advancements for osseointegration: A narrative review. Injury 2022; 53 Suppl 3:S69-S73. [PMID: 35948509 DOI: 10.1016/j.injury.2022.05.057] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 05/24/2022] [Accepted: 05/26/2022] [Indexed: 02/02/2023]
Abstract
Since ancient times, reduction and internal fixation has been applied to restore skeletal integrity. Despite advances in the understanding of fracture healing, the risk of complication such as implant loosening or implant-related infection still depicts a challenging complication. Nowadays, a great deal of research is devoted to unreveal the impact of implant surface modifications on osteogenic processes to enhance bone consolidation and osseointegration. This narrative review is aimed to (1) show the evolution and already achieved milestones of implant optimization, and (2) to outline the key factors that contribute to an enhanced osseointegration. Different physical and chemical roughening techniques are currently applied in various studies. Surface patterning on the nanoscale has been found to be an essential factor for the biological response, achievable by e.g. anodisation or laser texturing. Besides surface roughening, also different coating methods are vastly investigated. Next to metal or inorganic compounds as coating material, a variety of biomolecules is currently studied for their osteosupportive capacities. Osseointegration can be improved by surface modification on the micro and nanoscale. Bioactive agents can further improve the osseointegration potential. Used agents at the moment are e.g. inorganic compounds, growth factors (BMPs and non-BMPs) and antiresorptive drugs. The advancement in research on new implant generations therefore aims at actively supporting osseointegration processing.
Collapse
Affiliation(s)
- Nike Walter
- Department of Trauma Surgery, University Medical Centre, Regensburg, Germany
| | - Theresia Stich
- Department of Trauma Surgery, University Medical Centre, Regensburg, Germany
| | - Denitsa Docheva
- Department of Musculoskeletal Tissue Regeneration, Orthopaedic Hospital König-Ludwig-Haus, University of Wuerzburg, Wuerzburg, Germany
| | - Volker Alt
- Department of Trauma Surgery, University Medical Centre, Regensburg, Germany
| | - Markus Rupp
- Department of Trauma Surgery, University Medical Centre, Regensburg, Germany.
| |
Collapse
|
10
|
Jolic M, Sharma S, Palmquist A, Shah FA. The impact of medication on osseointegration and implant anchorage in bone determined using removal torque-A review. Heliyon 2022; 8:e10844. [PMID: 36276721 PMCID: PMC9582727 DOI: 10.1016/j.heliyon.2022.e10844] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/16/2022] [Accepted: 09/26/2022] [Indexed: 11/06/2022] Open
Abstract
Permanently anchored metal implants are frequently used in dental, craniomaxillofacial, and orthopaedic rehabilitation. The success of such therapies is owed to the phenomenon of osseointegration-the direct connection between the living bone and the implant. The extent of biomechanical anchorage (i.e., physical interlocking between the implant and bone) can be assessed with removal torque (RTQ) measurement. Implant anchorage is strongly influenced by underlying bone quality, involving physicochemical and biological properties such as composition and structural organisation of extracellular matrix, extent of micro-damage, and bone turnover. In this review, we evaluated the impact of various pharmacological agents on osseointegration, from animal experiments conducting RTQ measurements. In addition to substances whose antiresorptive and/or anti-catabolic effects on bone are well-documented (e.g., alendronate, zoledronate, ibandronate, raloxifene, human parathyroid hormone, odanacatib, and the sclerostin monoclonal antibody), positive effects on RTQ have been reported for substances that do not primarily target bone (e.g., aminoguanidine, insulin, losartan, simvastatin, bone morphogenetic protein, alpha-tocopherol, and the combination of silk fibroin powder and platelet-rich fibrin). On the contrary, several substances (e.g., prednisolone, cyclosporin A, cisplatin, and enamel matrix derivative) tend to adversely impact RTQ. While morphometric parameters such as bone-implant contact appear to influence the biomechanical anchorage, increased or decreased RTQ is not always accompanied by corresponding fluctuations in bone-implant contact. This further confirms that factors such as bone quality underpin biomechanical anchorage of metal implants. Several fundamental questions on drug metabolism and bioavailability, drug dosage, animal-to-human translation, and the consequences of treatment interruption remain yet unanswered.
Collapse
Affiliation(s)
- Martina Jolic
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, SE-405 30, Sweden
| | - Sonali Sharma
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, SE-405 30, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, SE-405 30, Sweden
| | - Furqan A. Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, SE-405 30, Sweden
| |
Collapse
|
11
|
Johansson ML, Shah FA, Eeg-Olofsson M, Monksfield P, Thomsen P, Palmquist A. Long-term osseointegration of laser-ablated hearing implants in sheep cranial bone. Front Surg 2022; 9:885964. [PMID: 36117815 PMCID: PMC9470750 DOI: 10.3389/fsurg.2022.885964] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 08/12/2022] [Indexed: 11/23/2022] Open
Abstract
Osseointegration, the ability for an implant to be anchored in bone tissue with direct bone-implant contact and allowing for continuous adaptive remodelling, is clinically used in different reconstructive fields, such as dentistry, orthopedics and otology. The latter uses a bone conducting sound processor connected to a skin-penetrating abutment that is mounted on a titanium implant placed in the temporal bone, thereby acting as a path for transmission of the vibrations generated by the sound processor. The success of the treatment relies on bone healing and osseointegration, which could be improved by surface modifications. The aim of this study was to evaluate the long-term osseointegration in a sheep skull model and compare a laser-ablated implant surface with a machined implant. Commercially available 4 mm titanium implants, either with a machined (Wide Ponto) or a laser-ablated surface (Ponto BHX, Oticon Medical, Sweden), were used in the current study. The surfaces were evaluated by scanning electron microscopy. The implantation was performed with a full soft tissue flap and the osteotomy was prepared using the MIPS drill kit (Oticon Medical, Sweden) prior to installation of the implants in the frontal bone of eight female sheep. After five months, biopsies including the implant and surrounding bone tissue obtained, processed and analysed using histology, histomorphometry, scanning electron microscopy and Raman spectroscopy. The animals healed well, without signs of adverse events. Histomorphometry showed a large amount of bone tissue around both implant types, with 75% of the threaded area occupied by bone for both implant types. A large amount of bone-implant contact was observed for both implant types, with 67%–71% of the surface covered by bone. Both implant types were surrounded by mature remodelled lamellar bone with high mineral content, corroborating the histological observations. The current results show that the laser-ablated surface induces healing similar to the well-known clinically used machined surface in ovine cranial bone. In conclusion, the present long-term experimental results indicate that a laser-ablated implant performs equally well as a clinically used implant with a machined surface. This, together with previously reported, improved early biomechanical anchorage, suggests future, safe and efficient clinical potential.
Collapse
Affiliation(s)
- Martin Lars Johansson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Research and Technology, Oticon Medical AB, Askim, Sweden
- Correspondence: Martin Lars Johansson
| | - Furqan A. Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Måns Eeg-Olofsson
- Department of Otorhinolaryngology Head and Neck Surgery, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Otorhinolaryngology, Head and Neck Surgery, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Peter Monksfield
- ENT Department, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Birmingham, United Kingdom
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
12
|
Titanium nanotopography induces osteocyte lacunar-canalicular networks to strengthen osseointegration. Acta Biomater 2022; 151:613-627. [PMID: 35995407 DOI: 10.1016/j.actbio.2022.08.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 08/09/2022] [Accepted: 08/12/2022] [Indexed: 11/20/2022]
Abstract
Osteocyte network architecture is closely associated with bone turnover. The cellular mechanosensing system regulates osteocyte dendrite formation by enhancing focal adhesion. Therefore, titanium surface nanotopography might affect osteocyte network architecture and improve the peri-implant bone tissue quality, leading to strengthened osseointegration of bone-anchored implants. We aimed to investigate the effects of titanium nanosurfaces on the development of osteocyte lacunar-canalicular networks and osseointegration of dental implants. Alkaline etching created titanium nanosurfaces with anisotropically patterned dense nanospikes, superhydrophilicity, and hydroxyl groups. MLO-Y4 mouse osteocyte-like cells cultured on titanium nanosurfaces developed neuron-like dendrites with increased focal adhesion assembly and gap junctions. Maturation was promoted in osteocytes cultured on titanium nanosurfaces compared to cells cultured on machined or acid-etched micro-roughened titanium surfaces. Osteocytes cultured in type I three-dimensional collagen gels for seven days on nano-roughened titanium surfaces displayed well-developed interconnectivity with highly developed dendrites and gap junctions compared to the poor interconnectivity observed on the other titanium surfaces. Even if superhydrophilicity and hydroxyl groups were maintained, the loss of anisotropy-patterned nanospikes reduced expression of gap junction in osteocytes cultured on alkaline-etched titanium nanosurfaces. Four weeks after placing the titanium nanosurface implants in the upper jawbone of wild-type rats, osteocytes with numerous dendrites were found directly attached to the implant surface, forming well-developed lacunar-canalicular networks around the nano-roughened titanium implants. The osseointegration strength of the nano-roughened titanium implants was significantly higher than that of the micro-roughened titanium implants. These data indicate that titanium nanosurfaces promote osteocyte lacunar-canalicular network development via nanotopographical cues and strengthen osseointegration. STATEMENT OF SIGNIFICANCE: The clinical stability of bone-anchoring implant devices is influenced by the bone quality. The osteocyte network potentially affects bone quality and is established by the three-dimensional (3D) connection of neuron-like dendrites of well-matured osteocytes within the bone matrix. No biomaterials are known to regulate formation of the osteocyte network. The present study provides the first demonstration that titanium nanosurfaces with nanospikes created by alkali-etching treatment enhance the 3D formation of osteocyte networks by promoting osteocyte dendrite formation and maturation by nanotopographic cues, leading to strengthened osseointegration of titanium implants. Osteocytes attached to the titanium nanosurfaces via numerous cellular projections. The success of osteocyte regulation by nanotechnology paves the way for development of epoch-making technologies to control bone quality.
Collapse
|
13
|
Hou C, An J, Zhao D, Ma X, Zhang W, Zhao W, Wu M, Zhang Z, Yuan F. Surface Modification Techniques to Produce Micro/Nano-scale Topographies on Ti-Based Implant Surfaces for Improved Osseointegration. Front Bioeng Biotechnol 2022; 10:835008. [PMID: 35402405 PMCID: PMC8990803 DOI: 10.3389/fbioe.2022.835008] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 03/08/2022] [Indexed: 12/24/2022] Open
Abstract
Titanium and titanium alloys are used as artificial bone substitutes due to the good mechanical properties and biocompatibility, and are widely applied in the treatment of bone defects in clinic. However, Pure titanium has stress shielding effect on bone, and the effect of titanium-based materials on promoting bone healing is not significant. To solve this problem, several studies have proposed that the surface of titanium-based implants can be modified to generate micro or nano structures and improve mechanical properties, which will have positive effects on bone healing. This article reviews the application and characteristics of several titanium processing methods, and explores the effects of different technologies on the surface characteristics, mechanical properties, cell behavior and osseointegration. The future research prospects in this field and the characteristics of ideal titanium-based implants are proposed.
Collapse
Affiliation(s)
- Chuang Hou
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Jing An
- Nursing Teaching and Research Department, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Duoyi Zhao
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Xiao Ma
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Weilin Zhang
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Wei Zhao
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Meng Wu
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
| | - Zhiyu Zhang
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
- *Correspondence: Zhiyu Zhang, ; Fusheng Yuan,
| | - Fusheng Yuan
- Department of Orthopedics, The Fourth Affiliated Hospital of China Medical University, Shenyang, China
- *Correspondence: Zhiyu Zhang, ; Fusheng Yuan,
| |
Collapse
|
14
|
Strijbos RM, Salameh S, Bezdjian A, Daniel SJ, Thomeer HGXM. The Minimally Invasive Star-Shaped Incision Technique and the Linear Incision Technique With Tissue Preservation for Percutaneous Bone Conduction Devices: A Retrospective Cohort Study. Front Surg 2022; 9:863997. [PMID: 35756480 PMCID: PMC9231669 DOI: 10.3389/fsurg.2022.863997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 02/21/2022] [Indexed: 11/13/2022] Open
Abstract
Purpose To compare intra- and postoperative outcomes between the standard linear incision technique with tissue preservation (LITT-P) and the minimally invasive star-shaped incision (SSI). Study Design A retrospective cohort study. Methods Primary outcomes evaluated operative time, implant survival, and intra-operative complications. A secondary outcome evaluated soft tissue tolerability assessed by the Holger's classification. Results A total of 38 implants were placed (19 LITT-P; 19 SSI). The median and mean surgical duration for the LITT-P group was statistically shorter than the SSI group (p = 0.0001). No intra-operative complications were reported for both surgical approaches. Five implants were lost during postoperative follow-up: one in the LITT-P and four in the SSI cohort. Both cohorts showed favorable soft tissue tolerability. Less Holgers 1 and 2 and more Holgers 3 soft tissue reactions were observed after the LITT-P compared to the SSI. Conclusion The novel SSI approach could be an alternative option based on the theoretical benefits and found favorable (and similar) soft tissue outcomes. Implant loss and surgical time are aspects to investigate regarding long-term durability and warrant further research.
Collapse
Affiliation(s)
- Ruben M. Strijbos
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht, Netherlands
- Brain Center UMC Utrecht, Utrecht, Netherlands
| | - Samer Salameh
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
| | - Aren Bezdjian
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
- Departments of Experimental Surgery and Pediatric Surgery, Faculty of Medicine, McGill University, Montreal, QC, Canada
| | - Sam J. Daniel
- Faculty of Medicine and Health Sciences, McGill University, Montreal, QC, Canada
- Department of Otolaryngology–Head, Neck Surgery, and Pediatric Surgery, Faculty of Medicine, McGill University, The Montreal Children's Hospital, Montreal, QC, Canada
| | - Hans GXM. Thomeer
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Center Utrecht, Utrecht, Netherlands
- Brain Center UMC Utrecht, Utrecht, Netherlands
- *Correspondence: Hans GXM. Thomeer
| |
Collapse
|
15
|
Osborne MS, Child-Hymas A, Holmberg M, Thomsen P, Johansson ML, McDermott AL. Clinical Evaluation of a Novel Laser-Ablated Titanium Implant System for Bone Anchored Hearing Systems in a Pediatric Population and the Relationship of Resonance Frequency Analysis With Implant Survival. Otol Neurotol 2022; 43:219-226. [PMID: 34816808 PMCID: PMC8746879 DOI: 10.1097/mao.0000000000003435] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To evaluate the clinical outcomes of pediatric patients implanted a novel 4.5 mm wide laser ablated titanium bone anchored implant system and to evaluate the implant stability over the first 12-month period. STUDY DESIGN A prospective, single-subject, repeated measure, cohort study. Participants served as their own controls. SETTING Community and tertiary referral hospital pediatric assessment center. PATIENTS A total of 115 consecutive pediatric patients aged 4 to 15 years were implanted with 176 laser ablated titanium bone anchored implants from January 2016 to January 2019. MAIN OUTCOME MEASURE Clinical outcomes, implant failure rates, and post implantation implant stability quotient (ISQ) scores were studied over the first 12-month period. Data were analyzed for statistical significance through mixed effect modeling, with the significance level p = 0.01. RESULTS A median 12-month survival of 96.6% was observed. Six implants (3.5%) were lost in total, one of these (0.6%) was lost due to trauma. Adverse skin reactions (Holgers grade 2-4) were observed in 4.4% of all postoperative visits, occurring in 22 individuals (19.1%). Neither the ISQ high (ISQH) nor ISQ low (ISQL) values increased significantly between the stage 1 and 2 surgeries. In contrast, the ISQ results, irrespective of abutment size, demonstrated an increasing trend from 49.1 to 57 over the 12 months review period. A statistically significant change was only demonstrated from the 3 months follow up onwards. CONCLUSION The use of 4.5 mm wide laser-ablated titanium bone anchored hearing implants resulted in superior survival rates and excellent clinical outcomes compared with previous implant systems.
Collapse
Affiliation(s)
| | | | | | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Martin L. Johansson
- Oticon Medical AB, Askim
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | | |
Collapse
|
16
|
Johansson ML, Hultén L, Jonsson O, Ben Amara H, Thomsen P, Edwin B. Achieving stomal continence with an ileal pouch and a percutaneous implant. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2022; 33:7. [PMID: 34982258 PMCID: PMC8727424 DOI: 10.1007/s10856-021-06633-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Accepted: 11/10/2021] [Indexed: 06/14/2023]
Abstract
In this study, a soft-tissue-anchored, percutaneous port used as a mechanical continence-preserving valve in reservoir ileo- and urostomies was functionally and morphologically evaluated in eight dogs. During follow-up, the skin failed to attach to the implant, but the intestine inside the stoma port appeared to be attached to the mesh. After reaching adequate reservoir volume, the urostomies were rendered continent by attaching a lid to the implant. The experiments were ended at different time intervals due to implant-related adverse events. In only one case did the histological evaluation reveal integration at both the implant-intestine and implant-skin interfaces, with a low degree of inflammation and the absence of bacterial colonisation. In the remaining cases, integration was not obtained and instead mucosal downgrowth and biofilm formation were observed. The skin-implant junction was characterised by the absence of direct contact between the epidermis and the implant. Varying degrees of epidermal downgrowth, granulation tissue formation, inflammatory cell infiltration and bacterial growth and biofilm formation were prominent findings. In contrast, the subcutaneously located anchor part of the titanium port was well integrated and encapsulated by fibrous tissue. These results demonstrate the opportunity to achieve integration between a soft-tissue-anchored titanium port, skin and intestine. However, predictable long-term function could not be achieved in these animal models due to implant- and non-implant-related adverse events. Unless barriers at both the implant-skin and implant-intestine junctions are created, epidermal and mucosal downward migration and biofilm formation will jeopardise implant performance.
Collapse
Affiliation(s)
- Martin L Johansson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| | - Leif Hultén
- Department of Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Olof Jonsson
- Department of Urology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Heithem Ben Amara
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Bjørn Edwin
- The Intervention Centre, Rikshospitalet, Oslo University Hospital, Oslo, Norway
- Department of Hepato-Pancreato-Biliary Surgery, Rikshospitalet, Oslo University Hospital, Oslo, Norway
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| |
Collapse
|
17
|
Stich T, Alagboso F, Křenek T, Kovářík T, Alt V, Docheva D. Implant-bone-interface: Reviewing the impact of titanium surface modifications on osteogenic processes in vitro and in vivo. Bioeng Transl Med 2022; 7:e10239. [PMID: 35079626 PMCID: PMC8780039 DOI: 10.1002/btm2.10239] [Citation(s) in RCA: 34] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 06/08/2021] [Accepted: 06/13/2021] [Indexed: 12/12/2022] Open
Abstract
Titanium is commonly and successfully used in dental and orthopedic implants. However, patients still have to face the risk of implant failure due to various reasons, such as implant loosening or infection. The risk of implant loosening can be countered by optimizing the osteointegration capacity of implant materials. Implant surface modifications for structuring, roughening and biological activation in favor for osteogenic differentiation have been vastly studied. A key factor for a successful stable long-term integration is the initial cellular response to the implant material. Hence, cell-material interactions, which are dependent on the surface parameters, need to be considered in the implant design. Therefore, this review starts with an introduction to the basics of cell-material interactions as well as common surface modification techniques. Afterwards, recent research on the impact of osteogenic processes in vitro and vivo provoked by various surface modifications is reviewed and discussed, in order to give an update on currently applied and developing implant modification techniques for enhancing osteointegration.
Collapse
Affiliation(s)
- Theresia Stich
- Experimental Trauma Surgery, Department of Trauma SurgeryUniversity Regensburg Medical CentreRegensburgGermany
| | - Francisca Alagboso
- Experimental Trauma Surgery, Department of Trauma SurgeryUniversity Regensburg Medical CentreRegensburgGermany
| | - Tomáš Křenek
- New Technologies Research CentreUniversity of West BohemiaPilsenCzech Republic
| | - Tomáš Kovářík
- New Technologies Research CentreUniversity of West BohemiaPilsenCzech Republic
| | - Volker Alt
- Experimental Trauma Surgery, Department of Trauma SurgeryUniversity Regensburg Medical CentreRegensburgGermany
- Clinic and Polyclinic for Trauma Surgery, University Regensburg Medical CentreRegensburgGermany
| | - Denitsa Docheva
- Experimental Trauma Surgery, Department of Trauma SurgeryUniversity Regensburg Medical CentreRegensburgGermany
| |
Collapse
|
18
|
Karazisis D, Rasmusson L, Petronis S, Palmquist A, Shah FA, Agheli H, Emanuelsson L, Johansson A, Omar O, Thomsen P. The effects of controlled nanotopography, machined topography and their combination on molecular activities, bone formation and biomechanical stability during osseointegration. Acta Biomater 2021; 136:279-290. [PMID: 34626821 DOI: 10.1016/j.actbio.2021.10.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 09/08/2021] [Accepted: 10/01/2021] [Indexed: 11/18/2022]
Abstract
The initial cellular and molecular activities at the bone interface of implants with controlled nanoscale topography and microscale roughness have previously been reported. However, the effects of such surface modifications on the development of osseointegration have not yet been determined. This study investigated the molecular events and the histological and biomechanical development of the bone interface in implants with nanoscale topography, microscale roughness or a combination of both. Polished and machined titanium implants with and without controlled nanopatterning (75 nm protrusions) were produced using colloidal lithography and coated with a thin titanium layer to unify the chemistry. The implants were inserted in rat tibiae and subjected to removal torque (RTQ) measurements, molecular analyses and histological analyses after 6, 21 and 28 days. The results showed that nanotopography superimposed on microrough, machined, surfaces promoted an early increase in RTQ and hence produced greater implant stability at 6 and 21 days. Two-way MANOVA revealed that the increased RTQ was influenced by microscale roughness and the combination of nanoscale and microscale topographies. Furthermore, increased bone-implant contact (BIC) was observed with the combined nanopatterned machined surface, although MANOVA results implied that the increased BIC was mainly dependent on microscale roughness. At the molecular level, the nanotopography, per se, and in synergy with microscale roughness, downregulated the expression of the proinflammatory cytokine tumor necrosis factor alpha (TNF-α). In conclusion, controlled nanotopography superimposed on microrough machined implants promoted implant stability during osseointegration. Nanoscale-driven mechanisms may involve attenuation of the inflammatory response at the titanium implant site. STATEMENT OF SIGNIFICANCE: The role of combined implant microscale and nanotopography features for osseointegration is incompletely understood. Using colloidal lithography technique, we created an ordered nanotopography pattern superimposed on screwshaped implants with microscale topography. The midterm and late molecular, bone-implant contact and removal torque responses were analysed in vivo. Nanotopography superimposed on microrough, machined, surfaces promoted the implant stability, influenced by microscale topography and the combination of nanoscale and microscale topographies. Increased bone-implant contact was mainly dependent on microscale roughness whereas the nanotopography, per se, and in synergy with microscale roughness, attenuated the proinflammatory tumor necrosis factor alpha (TNF-α) expression. It is concluded that microscale and nanopatterns provide individual as well as synergistic effects on molecular, morphological and biomechanical implant-tissue processes in vivo.
Collapse
Affiliation(s)
- Dimitrios Karazisis
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Oral and Maxillofacial Surgery, Sahlgrenska Academy, University of Gothenburg, Sweden
| | - Lars Rasmusson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden; Department of Oral and Maxillofacial Surgery, Sahlgrenska Academy, University of Gothenburg, Sweden; Maxillofacial unit, Linköping University Hospital, Linköping, Sweden
| | - Sarunas Petronis
- Chemistry, Biomaterials and Textiles, RISE Research Institutes of Sweden, Borås, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Hossein Agheli
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Lena Emanuelsson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anna Johansson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Omar Omar
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman bin Faisal University, Dammam, Saudi Arabia
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
| |
Collapse
|
19
|
Ren J, Paxton NC, Hammond J, Saifzadeh S, Steck R, Lawrence FA, Woodruff MA. Novel resin tissue array system reduces sample preparation time, labour and reagent costs in bone tissue histology. Bone 2021; 153:116155. [PMID: 34411775 DOI: 10.1016/j.bone.2021.116155] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 08/11/2021] [Accepted: 08/13/2021] [Indexed: 11/30/2022]
Abstract
Resin histology plays an essential role in the analysis of hard tissues, such as bone and teeth, as well as in the context of metallic implant analysis. However, the techniques of resin embedding, followed by ground sectioning, are very costly due to significantly increased reagent cost and labour time when compared to the conventional paraffin histology approach. In the present study, a novel resin array system was developed to increase the affordability of a project analysing rat femur tissues containing metallic or polymeric implants. The resin array system enabled the simultaneous embedding of the femur samples in groups of eight samples compared to the conventional resin method where samples are processed individually. The ground sections produced with the resin array system allowed uniform ROI selection, ground section thickness, staining consistency, and histological analysis with Goldner's trichrome stain, offering a substantial opportunity for reproducible immunohistochemistry which is unable to be achieved when processing samples embedded individually. The application of this novel resin array system significantly reduced resource usage when compared to doing the same analysis on individual samples. A reduction of approximately 40% was achieved for both total labour time and total reagent cost through the use of the array system compared with individual embedding. This novel resin array system has widespread applicability to many bone, hard tissue, and metallic implant studies, offering substantial conservation of research funds and increased accessibility to advanced techniques for commercial partners due to more cost-effective sample preparation and more accurate, reproducible data.
Collapse
Affiliation(s)
- Jiongyu Ren
- Queensland University of Technology (QUT), 2 George St, Brisbane, QLD 4000, Australia
| | - Naomi C Paxton
- Queensland University of Technology (QUT), 2 George St, Brisbane, QLD 4000, Australia
| | - Joshua Hammond
- Queensland University of Technology (QUT), 2 George St, Brisbane, QLD 4000, Australia
| | - Siamak Saifzadeh
- Queensland University of Technology (QUT), 2 George St, Brisbane, QLD 4000, Australia
| | - Roland Steck
- Queensland University of Technology (QUT), 2 George St, Brisbane, QLD 4000, Australia
| | - Felicity A Lawrence
- Queensland University of Technology (QUT), 2 George St, Brisbane, QLD 4000, Australia
| | - Maria A Woodruff
- Queensland University of Technology (QUT), 2 George St, Brisbane, QLD 4000, Australia.
| |
Collapse
|
20
|
Chen J, Yang Y, Etim IP, Tan L, Yang K, Misra RDK, Wang J, Su X. Recent Advances on Development of Hydroxyapatite Coating on Biodegradable Magnesium Alloys: A Review. MATERIALS 2021; 14:ma14195550. [PMID: 34639949 PMCID: PMC8509838 DOI: 10.3390/ma14195550] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 09/18/2021] [Accepted: 09/23/2021] [Indexed: 12/30/2022]
Abstract
The wide application of magnesium alloys as biodegradable implant materials is limited because of their fast degradation rate. Hydroxyapatite (HA) coating can reduce the degradation rate of Mg alloys and improve the biological activity of Mg alloys, and has the ability of bone induction and bone conduction. The preparation of HA coating on the surface of degradable Mg alloys can improve the existing problems, to a certain extent. This paper reviewed different preparation methods of HA coatings on biodegradable Mg alloys, and their effects on magnesium alloys’ degradation, biocompatibility, and osteogenic properties. However, no coating prepared can meet the above requirements. There was a lack of systematic research on the degradation of coating samples in vivo, and the osteogenic performance. Therefore, future research can focus on combining existing coating preparation technology and complementary advantages to develop new coating preparation techniques, to obtain more balanced coatings. Second, further study on the metabolic mechanism of HA-coated Mg alloys in vivo can help to predict its degradation behavior, and finally achieve controllable degradation, and further promote the study of the osteogenic effect of HA-coated Mg alloys in vivo.
Collapse
Affiliation(s)
- Junxiu Chen
- Key Laboratory of Materials Surface Science and Technology of Jiangsu Province, Changzhou University, Changzhou 213164, China; (Y.Y.); (J.W.); (X.S.)
- Jiangsu Collaborative Innovation Center of Photovoltaic Science and Engineering, Changzhou University, Changzhou 213164, China
- Correspondence: (J.C.); (K.Y.)
| | - Yang Yang
- Key Laboratory of Materials Surface Science and Technology of Jiangsu Province, Changzhou University, Changzhou 213164, China; (Y.Y.); (J.W.); (X.S.)
- Jiangsu Collaborative Innovation Center of Photovoltaic Science and Engineering, Changzhou University, Changzhou 213164, China
| | - Iniobong P. Etim
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China; (I.P.E.); (L.T.)
| | - Lili Tan
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China; (I.P.E.); (L.T.)
| | - Ke Yang
- Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China; (I.P.E.); (L.T.)
- Correspondence: (J.C.); (K.Y.)
| | - R. D. K. Misra
- Department of Metallurgical, Materials and Biomedical Engineering, University of Texas at El Paso, 500 West University Avenue, El Paso, TX 79968, USA;
| | - Jianhua Wang
- Key Laboratory of Materials Surface Science and Technology of Jiangsu Province, Changzhou University, Changzhou 213164, China; (Y.Y.); (J.W.); (X.S.)
- Jiangsu Collaborative Innovation Center of Photovoltaic Science and Engineering, Changzhou University, Changzhou 213164, China
| | - Xuping Su
- Key Laboratory of Materials Surface Science and Technology of Jiangsu Province, Changzhou University, Changzhou 213164, China; (Y.Y.); (J.W.); (X.S.)
- Jiangsu Collaborative Innovation Center of Photovoltaic Science and Engineering, Changzhou University, Changzhou 213164, China
| |
Collapse
|
21
|
Omar O, Abuohashish HM, Alkhamis T, Al-Qarni F. Habitual caffeine intake affects implant osseointegration: An in vivo study. J Periodontal Res 2021; 56:1070-1078. [PMID: 34363706 DOI: 10.1111/jre.12920] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2021] [Accepted: 07/27/2021] [Indexed: 01/12/2023]
Abstract
OBJECTIVES This study aimed to evaluate the effect of habitual caffeine (CAF) intake on stability, bone regeneration, and expression of bone markers at the bone-implant interface. BACKGROUND Studies show that habitual CAF alters bone health and remodeling. Yet, there is no information regarding CAF effects on osseointegration of bone-anchored implants. METHODS Wistar rats were divided into two groups: one received tap drinking water alone (control) and the other received tap water with CAF (300 mg/L). After 12 weeks, their tibiae received screw-shaped titanium implants. After another 12 weeks, CAF (n = 5) and control (n = 5) animals were sacrificed and the implant stability was evaluated using a removal torque (RTQ) device. Thereafter, the implants were processed for gene expression analysis, and the implantation sites were harvested for histology. Implants with the surrounding bone were dissected en bloc and subjected to micro-computed tomography (micro-CT). RESULTS The results showed that implants in the CAF group had an 87% significant increase in RTQ compared to the control. Further, micro-CT revealed a higher proportion of mineralized bone filling the implant threads in the CAF group. The molecular analysis indicated higher expression of bone formation (ALP), remodeling (CatK), and vascularization (VEGF) genes in implant-adherent cells in the CAF group. Histology suggested increased vascularity in the tissue surrounding the implant in the CAF group. CONCLUSIONS Within the limit of this study, it is concluded that habitual CAF intake conveys a positive, promoting effect on long-term osseointegration. Clinical studies are worth pursuing to verify this experimental observation.
Collapse
Affiliation(s)
- Omar Omar
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Hatem M Abuohashish
- Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Taleb Alkhamis
- Animal House, Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| | - Faisal Al-Qarni
- Department of Substitutive Dental Science, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam, Saudi Arabia
| |
Collapse
|
22
|
Primus T, Zeman P, Brajer J, Kožmín P, Syrovátka Š. An Experimental Investigation of Controlled Changes in Wettability of Laser-Treated Surfaces after Various Post Treatment Methods. MATERIALS 2021; 14:ma14092228. [PMID: 33926001 PMCID: PMC8123642 DOI: 10.3390/ma14092228] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/21/2021] [Accepted: 04/21/2021] [Indexed: 11/24/2022]
Abstract
In this paper, a quick nanosecond laser micro structuring process was employed to change the surface wettability of Ti6Al4V alloy. The same laser structuring method was used throughout, but with varying input fluence. The laser processing parameters resulted in high surface melting. After laser treatment, four post-processing methods were used, namely high vacuum, low temperature annealing, storage in a polyethylene bag, and storage in ambient air. Subsequently, the water droplet contact angle was measured over a long time period of 55 days. The results show that the sample stored in ambient air remained hydrophilic. On the other hand, the sample post-processed in a vacuum chamber behaved hydrophobically with a contact angle of approximately 150°. Other post-processing did not lead to specific wettability behavior. After wettability testing, all samples were cleaned ultrasonically in distilled water. This cleaning process led to annulation of all obtained properties through post-processing. In summary, this paper shows that it is more important to study surface chemistry than topography in terms of effects on wettability. Moreover, surface wettability can be controlled by laser structuring, post-processing, and surface cleaning.
Collapse
Affiliation(s)
- Tomáš Primus
- Department of Production Machines and Equipment, Faculty of Mechanical Engineering, Czech Technical University in Prague, 166 07 Prague, Czech Republic; (P.Z.); (J.B.)
- Correspondence: ; Tel.: +420-221990980
| | - Pavel Zeman
- Department of Production Machines and Equipment, Faculty of Mechanical Engineering, Czech Technical University in Prague, 166 07 Prague, Czech Republic; (P.Z.); (J.B.)
| | - Jan Brajer
- Department of Production Machines and Equipment, Faculty of Mechanical Engineering, Czech Technical University in Prague, 166 07 Prague, Czech Republic; (P.Z.); (J.B.)
| | - Pavel Kožmín
- Hofmeister s. r. o., 301 00 Plzeň, Czech Republic; (P.K.); (Š.S.)
| | - Šimon Syrovátka
- Hofmeister s. r. o., 301 00 Plzeň, Czech Republic; (P.K.); (Š.S.)
| |
Collapse
|
23
|
Li Y, Felländer-Tsai L. The bone anchored prostheses for amputees - Historical development, current status, and future aspects. Biomaterials 2021; 273:120836. [PMID: 33894405 DOI: 10.1016/j.biomaterials.2021.120836] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 03/28/2021] [Accepted: 04/14/2021] [Indexed: 12/27/2022]
Abstract
In the past 50 years, bone anchored prostheses have evolved from a concept for experimental treatment to a rapidly developing area in orthopedics and traumatology. Up to date, there are dozens of centers in the world providing osseointegration amputation reconstructions and more than a thousand patients using the bone anchored prostheses. Compared with conventional socket prostheses, the bone anchored prosthesis by osseointegration avoids the debilitating problems related with soft tissues. It also provides physiological weight bearing, improved range of motion, and sensory feedback, all of which contribute to the improvement on quality of life for amputees. The present article briefly reviews the historical development of osseointegration surgery for amputation reconstruction and the current challenges. The implant design characters and surgical techniques of the two types of implants; the screw-type implant (presented by the OPRA system), and the press-fit implants (presented by EEP and OPL systems) are described. The major complications, infections and mechanical failures, are discussed in detail based on the latest evidence. Future aspects and experimental trials aiming to overcome the current challenges are presented.
Collapse
Affiliation(s)
- Yan Li
- Division of Orthopaedics and Biotechnology, Department of Clinical Science Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden; Theme Trauma and Reparative Medicine, Department of Orthopedics and Traumatology, Karolinska University Hospital, Stockholm, Sweden
| | - Li Felländer-Tsai
- Division of Orthopaedics and Biotechnology, Department of Clinical Science Intervention and Technology (CLINTEC), Karolinska Institutet, Stockholm, Sweden; Theme Trauma and Reparative Medicine, Department of Orthopedics and Traumatology, Karolinska University Hospital, Stockholm, Sweden.
| |
Collapse
|
24
|
Kitagawa IL, Miyazaki CM, Pitol-Palin L, Okamoto R, de Vasconcellos LMR, Constantino CJL, Lisboa-Filho PN. Titanium-Based Alloy Surface Modification with TiO 2 and Poly(sodium 4-styrenesulfonate) Multilayers for Dental Implants. ACS APPLIED BIO MATERIALS 2021; 4:3055-3066. [PMID: 35014394 DOI: 10.1021/acsabm.0c01348] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Implant placement is an important repair method in dentistry and orthopedics. Increasing efforts have focused on optimizing the biocompatibility and osseointegration properties of titanium (Ti) and Ti-based alloys. In this work, Ti-based alloys were modified by the layer-by-layer (LbL) technique, which is a simple and versatile method for surface modification. The morphology and chemical structure of LbL films of poly(sodium 4-styrenesulfonate) (PSS) and Ti dioxide (TiO2) nanoparticles were first characterized employing ultraviolet-visible and Fourier-transform infrared spectroscopies as well as atomic force microscopy for further application in Ti-based alloy implants. The changes provoked by the LbL PSS/TiO2 film on the Ti-based alloy surfaces were then investigated by scanning electron microscopy and micro-Raman techniques. Finally, in vivo tests (immunolabeling and biomechanical analysis) performed with screw implants in rats suggested that PSS/TiO2 multilayers promote changes in both topography and chemical surface properties of the screw, providing beneficial effects for osteoblast activity. This simple and relatively low-cost growth process can open up possibilities to improve dental implants and, probably, bone implants in general.
Collapse
Affiliation(s)
- Igor L Kitagawa
- School of Sciences, Department of Physics, UNESP São Paulo State University, Bauru, São Paulo 17033-360, Brazil.,Science and Technology of São Paulo, IFSP Federal Institute of Education, Campus Birigui, Birigui, São Paulo 16201-407, Brazil
| | - Celina M Miyazaki
- CCTS, Federal University of São Carlos, Sorocaba, São Paulo 18052-780, Brazil
| | - Letícia Pitol-Palin
- Araçatuba Dental School, Department of Basic Science, UNESP São Paulo State University, Araçatuba 16018-805, Brazil
| | - Roberta Okamoto
- Araçatuba Dental School, Department of Basic Science, UNESP São Paulo State University, Araçatuba 16018-805, Brazil
| | - Luana M R de Vasconcellos
- Institute of Science and Technology, Department of Biosciences and Oral Diagnosis, UNESP São Paulo State University, São José dos Campos, São Paulo 12245-000, Brazil
| | - Carlos J L Constantino
- School of Technology and Applied Sciences, Department of Physics, UNESP São Paulo State University, Presidente Prudente, São Paulo 19060-900, Brazil
| | - Paulo N Lisboa-Filho
- School of Sciences, Department of Physics, UNESP São Paulo State University, Bauru, São Paulo 17033-360, Brazil
| |
Collapse
|
25
|
Johansson ML, Calon TGA, Omar O, Shah FA, Trobos M, Thomsen P, Stokroos RJ, Palmquist A. Multimodal Analysis of the Tissue Response to a Bone-Anchored Hearing Implant: Presentation of a Two-Year Case Report of a Patient With Recurrent Pain, Inflammation, and Infection, Including a Systematic Literature Review. Front Cell Infect Microbiol 2021; 11:640899. [PMID: 33859952 PMCID: PMC8042154 DOI: 10.3389/fcimb.2021.640899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Accepted: 03/03/2021] [Indexed: 12/04/2022] Open
Abstract
Osseointegration is a well-established concept used in applications including the percutaneous Bone-Anchored Hearing System (BAHS) and auricular rehabilitation. To date, few retrieved implants have been described. A systematic review including cases where percutaneous bone-anchored implants inserted in the temporal bone were retrieved and analyzed was performed. We also present the case of a patient who received a BAHS for mixed hearing loss. After the initial surgery, several episodes of soft tissue inflammation accompanied by pain were observed, leading to elective abutment removal 14 months post-surgery. Two years post-implantation, the implant was removed due to pain and subjected to a multiscale and multimodal analysis: microbial DNA using molecular fingerprinting, gene expression using quantitative real-time polymerase chain reaction (qPCR), X-ray microcomputed tomography (micro-CT), histology, histomorphometry, backscattered scanning electron microscopy (BSE-SEM), Raman spectroscopy, and fluorescence in situ hybridization (FISH). Evidence of osseointegration was provided via micro-CT, histology, BSE-SEM, and Raman spectroscopy. Polymicrobial colonization in the periabutment area and on the implant, including that with Staphylococcus aureus and Staphylococcus epidermidis, was determined using a molecular analysis via a 16S-23S rDNA interspace [IS]-region-based profiling method (IS-Pro). The histology suggested bacterial colonization in the skin and in the peri-implant bone. FISH confirmed the localization of S. aureus and coagulase-negative staphylococci in the skin. Ten articles (54 implants, 47 patients) met the inclusion criteria for the literature search. The analyzed samples were either BAHS (35 implants) or bone-anchored aural epitheses (19 implants) in situ between 2 weeks and 8 years. The main reasons for elective removal were nonuse/changes in treatment, pain, or skin reactions. Most samples were evaluated using histology, demonstrating osseointegration, but with the absence of bone under the implants’ proximal flange. Taken together, the literature and this case report show clear evidence of osseointegration, despite prominent complications. Nevertheless, despite implant osseointegration, chronic pain related to the BAHS may be associated with a chronic bacterial infection and raised inflammatory response in the absence of macroscopic signs of infection. It is suggested that a multimodal analysis of peri-implant health provides possibilities for device improvements and to guide diagnostic and therapeutic strategies to alleviate the impact of complications.
Collapse
Affiliation(s)
- Martin L Johansson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Research and Technology, Oticon Medical AB, Askim, Sweden
| | - Tim G A Calon
- Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht, Netherlands
| | - Omar Omar
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Margarita Trobos
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Robert J Stokroos
- Department of Otorhinolaryngology, Head and Neck Surgery, Maastricht University Medical Center, Maastricht, Netherlands.,Department of Otorhinolaryngology, Head and Neck Surgery, University Medical Center Utrecht, Utrecht, Netherlands
| | - Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
26
|
Han J, Zhang F, Van Meerbeek B, Vleugels J, Braem A, Castagne S. Laser surface texturing of zirconia-based ceramics for dental applications: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 123:112034. [PMID: 33812647 DOI: 10.1016/j.msec.2021.112034] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 03/02/2021] [Accepted: 03/05/2021] [Indexed: 02/07/2023]
Abstract
Laser surface texturing is widely explored for modifying the surface topography of various materials and thereby tuning their optical, tribological, biological, and other surface properties. In dentistry, improved osseointegration has been observed with laser textured titanium dental implants in clinical trials. Due to several limitations of titanium materials, dental implants made of zirconia-based ceramics are now considered as one of the best alternatives. Laser surface texturing of zirconia dental implants is therefore attracting increasing attention. However, due to the brittle nature of zirconia, as well as the metastable tetragonal ZrO2 phase, laser texturing in the case of zirconia is more challenging than in the case of titanium. Understanding these challenges requires different fields of expertise, including laser engineering, materials science, and dentistry. Even though much progress was made within each field of expertise, a comprehensive analysis of all the related factors is still missing. This review paper provides thus an overview of the common challenges and current status on the use of lasers for surface texturing of zirconia-based ceramics for dental applications, including texturing of zirconia implants for improving osseointegration, texturing of zirconia abutments for reducing peri-implant inflammation, and texturing of zirconia restorations for improving restoration retention by bonding.
Collapse
Affiliation(s)
- Jide Han
- KU Leuven, Department of Mechanical Engineering and Flanders Make@KU Leuven-MaPS, Celestijnenlaan 300, 3001 Leuven, Belgium
| | - Fei Zhang
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium; KU Leuven, Department of Oral Health Sciences, BIOMAT, Kapucijnenvoer 7 Block A, 3000 Leuven, Belgium
| | - Bart Van Meerbeek
- KU Leuven, Department of Oral Health Sciences, BIOMAT, Kapucijnenvoer 7 Block A, 3000 Leuven, Belgium
| | - Jozef Vleugels
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium
| | - Annabel Braem
- KU Leuven, Department of Materials Engineering, Kasteelpark Arenberg 44, 3001 Leuven, Belgium
| | - Sylvie Castagne
- KU Leuven, Department of Mechanical Engineering and Flanders Make@KU Leuven-MaPS, Celestijnenlaan 300, 3001 Leuven, Belgium.
| |
Collapse
|
27
|
Strijbos RM, Straatman LV, Calon TGA, Johansson ML, de Bruijn AJG, van den Berge H, Wagenaar M, Eichhorn E, Janssen M, Jonhede S, van Tongeren J, Holmberg M, Stokroos R. Long-Term Outcomes of the Minimally Invasive Ponto Surgery vs. Linear Incision Technique With Soft Tissue Preservation for Installation of Percutaneous Bone Conduction Devices. Front Neurol 2021; 12:632987. [PMID: 33716934 PMCID: PMC7945693 DOI: 10.3389/fneur.2021.632987] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Accepted: 01/19/2021] [Indexed: 12/19/2022] Open
Abstract
Objective: Comparing the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with the linear incision technique with soft tissue preservation (LITT-P) for bone conduction devices after a follow-up of 22 months. Methods: In this multicenter randomized controlled trial, there was the inclusion of 64 adult patients eligible for unilateral surgery. There was 1:1 randomization to the MIPS (test) or the LITT-P (control) group. The primary outcome was an (adverse) soft tissue reaction. Secondary outcomes were pain, loss of sensibility, soft tissue height/overgrowth, skin sagging, implant loss, Implant Stability Quotient measurements, cosmetic scores, and quality of life questionnaires. Results: Sixty-three subjects were analyzed in the intention-to-treat population. No differences were found in the presence of (adverse) soft tissue reactions during complete follow-up. Also, there were no differences in pain, wound dehiscence, skin level, soft tissue overgrowth, and overall quality of life. Loss of sensibility (until 3-month post-surgery), cosmetic scores, and skin sagging outcomes were better in the MIPS group. The Implant Stability Quotient was higher after the LITT-P for different abutment lengths at various points of follow-up. Implant extrusion was nonsignificantly higher after the MIPS (15.2%) compared with LITT-P (3.3%). Conclusion: The long-term results show favorable outcomes for both techniques. The MIPS is a promising technique with some benefits over the LITT-P. Concerns regarding nonsignificantly higher implant loss may be overcome with future developments and research. Clinical Trial Registration:www.ClinicalTrials.gov, identifier: NCT02438618.
Collapse
Affiliation(s)
- Ruben M Strijbos
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Centre Utrecht, Utrecht, Netherlands.,University Medical Centre Utrecht Brain Centre, University of Utrecht, Utrecht, Netherlands
| | - Louise V Straatman
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Centre Utrecht, Utrecht, Netherlands.,University Medical Centre Utrecht Brain Centre, University of Utrecht, Utrecht, Netherlands
| | - Tim G A Calon
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Centre Utrecht, Utrecht, Netherlands.,University Medical Centre Utrecht Brain Centre, University of Utrecht, Utrecht, Netherlands
| | - Martin L Johansson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Oticon Medical AB, Askim, Sweden
| | | | - Herbert van den Berge
- Department of Otorhinolaryngology, Medisch Centrum Leeuwarden, Leeuwarden, Netherlands
| | - Mariette Wagenaar
- Department of Otorhinolaryngology, Medisch Centrum Leeuwarden, Leeuwarden, Netherlands
| | - Edwin Eichhorn
- Department of Otorhinolaryngology, Medisch Centrum Leeuwarden, Leeuwarden, Netherlands
| | - Miranda Janssen
- Department of Otorhinolaryngology and Head and Neck Surgery, Maastricht University Medical Centre, Maastricht, Netherlands.,Department of Methodology and Statistics, Care and Public Health Research Institute, Maastricht University, Maastricht, Netherlands
| | | | - Joost van Tongeren
- Department of Otorhinolaryngology and Head and Neck Surgery, Maastricht University Medical Centre, Maastricht, Netherlands
| | | | - Robert Stokroos
- Department of Otorhinolaryngology and Head and Neck Surgery, University Medical Centre Utrecht, Utrecht, Netherlands.,University Medical Centre Utrecht Brain Centre, University of Utrecht, Utrecht, Netherlands
| |
Collapse
|
28
|
Lagerkvist H, Carvalho K, Holmberg M, Petersson U, Cremers C, Hultcrantz M. Ten years of experience with the Ponto bone-anchored hearing system-A systematic literature review. Clin Otolaryngol 2020; 45:667-680. [PMID: 32386454 PMCID: PMC7496709 DOI: 10.1111/coa.13556] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Accepted: 04/18/2020] [Indexed: 12/17/2022]
Abstract
Background Bone‐anchored hearing systems (BAHSs) are widely used for hearing rehabilitation and are indicated in cases of conductive and mixed hearing loss and in single‐sided deafness. The Ponto system, that is one available option, has been on the market since 2009. Objective of review The aim of this study is to systematically review the literature reporting on the Ponto system, with regard to audiological and surgical outcomes and patient's quality‐of‐life scores. Type of review A systematic literature search was performed in the PubMed database 2009‐July 2019. Search strategy Search term: ((osseointegrated hearing aid) OR (bone conduction implant) OR (bone anchored hearing) OR BAHA OR BAHS OR BAHI). Pre‐defined inclusion and exclusion criteria were applied. Evaluation method English‐language articles reporting original clinical data (audiological, surgical or quality‐of‐life outcomes) on the Ponto system were included. Articles reporting on Ponto and another BAHS system where the results on Ponto constituted less than 50% of the patient population or including only results on testband or softband devices were excluded. Results Audiological outcomes were discussed in 20 publications. Improvement against the unaided thresholds was demonstrated. The functional improvement was on average 33.9 dB. The effective gain or remaining air‐bone gap was on average 6.7 dB. All evaluated data showed aided speech reception thresholds significantly below normal speech level. Twenty‐seven publications reported surgical and follow‐up data for the Ponto system. Implant survival was 97.7%, adverse skin reactions (Holgers ≥ 2) were 5% across visits and 15% across patients. No complications were life‐threatening, causing permanent disability/damage or requiring a hospitalisation. Five studies reported quality of life using the Glasgow benefit inventory, 98% reported an improvement when analysing the score on an individual level. Conclusions The outcomes of this systematic review confirm that percutaneous systems provide consistent audiological benefits and improved quality of life for patients. Further, the review demonstrates that the percutaneous systems are safe, with relatively low complication rates. Skin‐related complications are the most common complication type and are experienced by approximately one patient out of seven, or in less than one of 20 follow‐up visits.
Collapse
Affiliation(s)
| | | | | | | | - Cor Cremers
- Department of Otorhinolaryngology, Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre Nijmegen, Nijmegen, The Netherlands
| | | |
Collapse
|
29
|
Novel Minimal Access Bone Anchored Hearing Implant Surgery and a New Surface Modified Titanium Implant, the Birmingham Experience. Otol Neurotol 2019; 40:1326-1332. [DOI: 10.1097/mao.0000000000002423] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
30
|
Bezdjian A, Smith RA, Gabra N, Yang L, Bianchi M, Daniel SJ. Experience with Minimally Invasive Ponto Surgery and Linear Incision Approach for Pediatric and Adult Bone Anchored Hearing Implants. Ann Otol Rhinol Laryngol 2019; 129:380-387. [DOI: 10.1177/0003489419891451] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To compare intra- and postoperative outcomes between the standard linear incision with tissue preservation and the Minimally Invasive Ponto Surgery (MIPS). Study Design: A non-randomized retrospective cohort series. Methods: Medical files were reviewed of adult and pediatric bone anchored hearing implant recipients. Extracted outcomes included patient characteristics, implant survival, operative time, anesthesia use, intra and postoperative complications, soft tissue tolerability assessed by the Holger’s classification, and implant stability assessed by the Resonance Frequency Analysis (RFA). Outcomes were compared between two surgeries. Results: A total of 59 implants were placed (21 MIPS; 38 linear). Conductive hearing loss was the most common etiology for implantation. Surgery was conducted under local anesthesia in 67% of MIPS patients and 16% of linear patients. No intraoperative complications were reported for both surgical approaches and no implants were lost. Patients undergoing implantation via the MIPS approach displayed less skin reaction postoperatively, however this was not significant ( P = .2848). The most common Holgers score for both groups was grade 1. The median and mean surgical duration for the MIPS group was statistically lower than the linear group ( P = .0001). Implant stability measured by the RFA implant stability quotient was greater in the MIPS cohort. Conclusion: The MIPS approach seems either similar or superior to the linear approach in all perioperative outcomes evaluated. Outcomes such as surgical duration, anesthesia choice and implant stability measurements support implantation through the MIPS approach for patients meeting eligibility criteria.
Collapse
Affiliation(s)
| | | | | | - Luhe Yang
- McGill University, Montreal, QC, Canada
| | | | | |
Collapse
|
31
|
Kaur M, Singh K. Review on titanium and titanium based alloys as biomaterials for orthopaedic applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 102:844-862. [PMID: 31147056 DOI: 10.1016/j.msec.2019.04.064] [Citation(s) in RCA: 398] [Impact Index Per Article: 79.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 02/20/2019] [Accepted: 04/20/2019] [Indexed: 02/07/2023]
Abstract
Variety of implant materials have been employed in various disciplines of medical science depending on the requirement of a particular application. Metals, alloys, ceramics, and polymers are the commonly used biomaterials. The main focus of this study is to review the various structural and microstructural properties of titanium and titanium based alloys used as orthopaedic implants. Orthopaedic implants need to possess certain important qualities to ensure their safe and effective use. These properties like the biocompatibility, relevant mechanical properties, high corrosion and wear resistance and osseointegration are summarized in this review. Various attempts to improve upon these properties like different processing routes, surface modifications have also been inculcated in the paper to provide an insight into the extent of research and effort that has been put into developing a highly superior titanium orthopaedic implant.
Collapse
Affiliation(s)
- Manmeet Kaur
- School of Physics and Materials Science, Thapar Institute of Engineering and Technology, Patiala, Punjab 147004, India
| | - K Singh
- School of Physics and Materials Science, Thapar Institute of Engineering and Technology, Patiala, Punjab 147004, India.
| |
Collapse
|
32
|
Huang Z, Wang Z, Li C, Zhou N, Liu F, Lan J. The osteoinduction of RGD and Mg ion functionalized bioactive zirconia coating. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2019; 30:95. [PMID: 31414276 DOI: 10.1007/s10856-019-6298-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Accepted: 08/01/2019] [Indexed: 06/10/2023]
Abstract
The objective of this study was to investigate the adhesion, proliferation and mineralization of osteoblasts on arginine-glycine-aspartic acid (RGD)- and magnesium ion (Mg+)-decorated zirconia coatings. The zirconia coatings were prepared via a plasma spray; RGD and Mg+ were immobilized via a silane-coupling agent and ion implantation, respectively. This study employed scanning electron microscopy (SEM) to observe the surface morphology of RGD- and Mg+-decorated zirconia coatings; surface roughness and wettability were also measured. The initial adhesion of osteoblasts was measured, and cell morphology and focal adhesion were observed. In addition, the expressions of the integrins a1, a2, a5, av, and ß1 were measured using RT-PCR. A cell count was conducted to measure proliferation. The expressions of ALP and OCN were detected based on a western blot analysis, and mineralized nodules were observed to visualize the mineralization of osteoblasts. A nanoscale surface structure could be found on the Mg+-decorated zirconia coating, and the RGD-decorated zirconia coating showed better wettability (p < 0.05). Cells on the RGD- and Mg+-decorated zirconia coating possessed better spreading properties than did cells on nondecorated surfaces, and more focal adhesion was observed. The higher expressions of the integrins a5, av and ß1 were found on the RGD-decorated zirconia coating (p < 0.05). The western blot results demonstrated that the introduction of Mg+ heightened the expressions of ALP and OCN. More and bigger mineralized nodules were observed on the Mg+- and RGD-decorated zirconia coating, which consisted of small mineralized nodules. RGD- and Mg+-functionalized zirconia coating facilitates the osteogenic reaction of osteoblasts. RGD improves the adhesion of osteoblasts, and Mg+ benefits the mineralization of osteoblasts. In addition, a synergistic effect was found between RGD and Mg+, allowing better performances with regard to adhesion, proliferation and mineralization when the two were used together rather than as separate decorations.
Collapse
Affiliation(s)
- Zhengfei Huang
- Shandong Provincial Key Laboratory of Oral Tissue Regeneration, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
- Department of Prosthodontics, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
| | - Zhifeng Wang
- Shandong Provincial Key Laboratory of Oral Tissue Regeneration, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
- Department of Pediatric Dentistry, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
| | - Chuanhua Li
- Shandong Provincial Key Laboratory of Oral Tissue Regeneration, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
- Department of Prosthodontics, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
| | - Ning Zhou
- Shandong Provincial Key Laboratory of Oral Tissue Regeneration, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
- Department of Orthodontics, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
| | - Fei Liu
- Shandong Provincial Key Laboratory of Oral Tissue Regeneration, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
- Department of Prosthodontics, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China
| | - Jing Lan
- Shandong Provincial Key Laboratory of Oral Tissue Regeneration, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China.
- Department of Prosthodontics, School of Stomatology, Shandong University, 44-1 Wenhua Road West, Jinan, 250012, Shandong, China.
| |
Collapse
|
33
|
A Study of Laser Micromachining of PM Processed Ti Compact for Dental Implants Applications. MATERIALS 2019; 12:ma12142246. [PMID: 31336851 PMCID: PMC6678598 DOI: 10.3390/ma12142246] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 07/08/2019] [Accepted: 07/10/2019] [Indexed: 01/28/2023]
Abstract
The paper deals with the experimental study of laser beam micromachining of the powder metallurgy processed Ti compacts applying the industrial grade fibre nanosecond laser operating at the wavelength of 1064 nm. The influence of the laser energy density on the surface roughness, surface morphology and surface elements composition was investigated and evaluated by means of surface roughness measurement, scanning electron microscopy (SEM), energy dispersive X-Ray spectroscopy (EDS) and X-ray diffraction (XRD) analysis. The different laser treatment parameters resulted in the surfaces of very different characteristics of the newly developed biocompatible material prepared by advanced low temperature technology of hydride dehydride (HDH) titanium powder compactation. The results indicate that the laser pulse energy has remarkable effects on the machined surface characteristics which are discussed from the point of view of application in dental implantology.
Collapse
|
34
|
Hériveaux Y, Nguyen VH, Brailovski V, Gorny C, Haïat G. Reflection of an ultrasonic wave on the bone-implant interface: Effect of the roughness parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:3370. [PMID: 31255165 DOI: 10.1121/1.5109668] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 05/10/2019] [Indexed: 06/09/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The aim of this study is to derive the main determinants of the ultrasonic response of the BII during osseointegration phenomena. The influence of (i) the surface roughness parameters and (ii) the thickness W of a soft tissue layer on the reflection coefficient r of the BII was investigated using a two-dimensional finite element model. When W increases from 0 to 150 μm, r increases from values in the range [0.45; 0.55] to values in the range [0.75; 0.88] according to the roughness parameters. An optimization method was developed to determine the sinusoidal roughness profile leading to the most similar ultrasonic response for all values of W compared to the original profile. The results show that the difference between the ultrasonic responses of the optimal sinusoidal profile and of the original profile was lower to typical experimental errors. This approach provides a better understanding of the ultrasonic response of the BII, which may be used in future numerical simulation realized at the scale of an implant.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vladimir Brailovski
- Department of Mechanical Engineering, École de technologie supérieure, 1100 Notre-Dame Street West, Montreal, Quebec H3C 1K3, Canada
| | - Cyril Gorny
- Laboratoire PIMM (ENSAM, CNRS, CNAM, Hesam Université), 151 Bd de l'Hôpital 75013 Paris (ENSAM), France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
35
|
Shah FA, Ruscsák K, Palmquist A. 50 years of scanning electron microscopy of bone-a comprehensive overview of the important discoveries made and insights gained into bone material properties in health, disease, and taphonomy. Bone Res 2019; 7:15. [PMID: 31123620 PMCID: PMC6531483 DOI: 10.1038/s41413-019-0053-z] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2019] [Revised: 04/09/2019] [Accepted: 04/11/2019] [Indexed: 02/06/2023] Open
Abstract
Bone is an architecturally complex system that constantly undergoes structural and functional optimisation through renewal and repair. The scanning electron microscope (SEM) is among the most frequently used instruments for examining bone. It offers the key advantage of very high spatial resolution coupled with a large depth of field and wide field of view. Interactions between incident electrons and atoms on the sample surface generate backscattered electrons, secondary electrons, and various other signals including X-rays that relay compositional and topographical information. Through selective removal or preservation of specific tissue components (organic, inorganic, cellular, vascular), their individual contribution(s) to the overall functional competence can be elucidated. With few restrictions on sample geometry and a variety of applicable sample-processing routes, a given sample may be conveniently adapted for multiple analytical methods. While a conventional SEM operates at high vacuum conditions that demand clean, dry, and electrically conductive samples, non-conductive materials (e.g., bone) can be imaged without significant modification from the natural state using an environmental scanning electron microscope. This review highlights important insights gained into bone microstructure and pathophysiology, bone response to implanted biomaterials, elemental analysis, SEM in paleoarchaeology, 3D imaging using focused ion beam techniques, correlative microscopy and in situ experiments. The capacity to image seamlessly across multiple length scales within the meso-micro-nano-continuum, the SEM lends itself to many unique and diverse applications, which attest to the versatility and user-friendly nature of this instrument for studying bone. Significant technological developments are anticipated for analysing bone using the SEM.
Collapse
Affiliation(s)
- Furqan A. Shah
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Krisztina Ruscsák
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| |
Collapse
|
36
|
Response of Saos-2 osteoblast-like cells to laser surface texturing, sandblasting and hydroxyapatite coating on CoCrMo alloy surfaces. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 98:1005-1013. [DOI: 10.1016/j.msec.2019.01.067] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2018] [Revised: 01/15/2019] [Accepted: 01/15/2019] [Indexed: 12/22/2022]
|
37
|
Luo Y, Li D, Xie X, Kang P. Porous, lithium-doped calcium polyphosphate composite scaffolds containing vascular endothelial growth factor (VEGF)-loaded gelatin microspheres for treating glucocorticoid-induced osteonecrosis of the femoral head. Biomed Mater 2019; 14:035013. [DOI: 10.1088/1748-605x/ab0a55] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
38
|
|
39
|
Shah FA, Thomsen P, Palmquist A. Osseointegration and current interpretations of the bone-implant interface. Acta Biomater 2019; 84:1-15. [PMID: 30445157 DOI: 10.1016/j.actbio.2018.11.018] [Citation(s) in RCA: 156] [Impact Index Per Article: 31.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Revised: 10/28/2018] [Accepted: 11/12/2018] [Indexed: 02/07/2023]
Abstract
Complex physical and chemical interactions take place in the interface between the implant surface and bone. Various descriptions of the ultrastructural arrangement to various implant design features, ranging from solid and macroporous geometries to surface modifications on the micron-, submicron-, and nano- levels, have been put forward. Here, the current knowledge regarding structural organisation of the bone-implant interface is reviewed with a focus on solid devices, mainly metal (or alloy) intended for permanent anchorage in bone. Certain biomaterials that undergo surface and bulk degradation are also considered. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin. In the published literature, as many as eight distinct arrangements of the bone-implant interface ultrastructure have been described. The interpretation is influenced by the in vivo model and species-specific characteristics, healing time point(s), physico-chemical properties of the implant surface, implant geometry, sample preparation route(s) and associated artefacts, analytical technique(s) and their limitations, and non-compromised vs compromised local tissue conditions. The understanding of the ultrastructure of the interface under experimental conditions is rapidly evolving due to the introduction of novel techniques for sample preparation and analysis. Nevertheless, the current understanding of the interface zone in humans in relation to clinical implant performance is still hampered by the shortcomings of clinical methods for resolving the finer details of the bone-implant interface. STATEMENT OF SIGNIFICANCE: Being a hierarchical material by design, the overall strength of bone is governed by composition and structure. Understanding the structure of the bone-implant interface is essential in the development of novel bone repair materials and strategies, and their long-term success. Here, the current knowledge regarding the eventual structural organisation of the bone-implant interface is reviewed, with a focus on solid devices intended for permanent anchorage in bone, and certain biomaterials that undergo surface and bulk degradation. The bone-implant interface is a heterogeneous zone consisting of mineralised, partially mineralised, and unmineralised areas. Within the meso-micro-nano-continuum, mineralised collagen fibrils form the structural basis of the bone-implant interface, in addition to accumulation of non-collagenous macromolecules such as osteopontin, bone sialoprotein, and osteocalcin.
Collapse
|
40
|
A Systematic Review on Factors Associated With Percutaneous Bone Anchored Hearing Implants Loss. Otol Neurotol 2018; 39:e897-e906. [DOI: 10.1097/mao.0000000000002041] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
41
|
Abstract
In lamellar bone, a network of highly oriented interconnected osteocytes is organized in concentric layers. Through their cellular processes contained within canaliculi, osteocytes are highly mechanosensitive and locally modulate bone remodeling. We review the recent developments demonstrating the significance of the osteocyte lacuno-canalicular network in bone maintenance around implant biomaterials. Drilling during implant site preparation triggers osteocyte apoptosis, the magnitude of which correlates with drilling speed and heat generation, resulting in extensive remodeling and delayed healing. In peri-implant bone, osteocytes physically communicate with implant surfaces via canaliculi and are responsive to mechanical loading, leading to changes in osteocyte numbers and morphology. Certain implant design features allow peri-implant osteocytes to retain a less aged phenotype, despite highly advanced extracellular matrix maturation. Physicochemical properties of anodically oxidized surfaces stimulate bone formation and remodeling by regulating the expression of RANKL (receptor activator of nuclear factor-κB ligand), RANK, and OPG (osteoprotegerin) from implant-adherent cells. Modulation of certain osteocyte-related molecular signaling mechanisms (e.g., sclerostin blockade) may enhance the biomechanical anchorage of implants. Evaluation of the peri-implant osteocyte lacuno-canalicular network should therefore be a necessary component in future investigations of osseointegration to more completely characterize the biological response to materials for load-bearing applications in dentistry and orthopedics.
Collapse
Affiliation(s)
- F A Shah
- 1 Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - P Thomsen
- 1 Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - A Palmquist
- 1 Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| |
Collapse
|
42
|
Palmquist A. A multiscale analytical approach to evaluate osseointegration. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2018; 29:60. [PMID: 29736606 PMCID: PMC5938308 DOI: 10.1007/s10856-018-6068-y] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Accepted: 04/18/2018] [Indexed: 06/08/2023]
Abstract
Osseointegrated implants are frequently used in reconstructive surgery, both in the dental and orthopedic field, restoring physical function and improving the quality of life for the patients. The bone anchorage is typically evaluated at micrometer resolution, while bone tissue is a dynamic composite material composed of nanoscale collagen fibrils and apatite crystals, with defined hierarchical levels at different length scales. In order to understand the bone formation and the ultrastructure of the interfacial tissue, analytical strategies needs to be implemented enabling multiscale and multimodal analyses of the intact interface. This paper describes a sample preparation route for successive analyses allowing assessment of the different hierarchical levels of interest, going from macro to nano scale and could be implemented on single samples. Examples of resulting analyses of different techniques on one type of implant surface is given, with emphasis on correlating the length scale between the different techniques. The bone-implant interface shows an intimate contact between mineralized collagen bundles and the outermost surface of the oxide layer, while bone mineral is found in the nanoscale surface features creating a functionally graded interface. Osteocytes exhibit a direct contact with the implant surface via canaliculi that house their dendritic processes. Blood vessels are frequently found in close proximity to the implant surface either within the mineralized bone matrix or at regions of remodeling.
Collapse
Affiliation(s)
- Anders Palmquist
- Department of Biomaterials, Sahlgrenska Academy at University of Gothenburg, Göteborg, Sweden.
| |
Collapse
|
43
|
Trobos M, Johansson ML, Jonhede S, Peters H, Hoffman M, Omar O, Thomsen P, Hultcrantz M. The clinical outcome and microbiological profile of bone-anchored hearing systems (BAHS) with different abutment topographies: a prospective pilot study. Eur Arch Otorhinolaryngol 2018; 275:1395-1408. [PMID: 29623410 PMCID: PMC5951894 DOI: 10.1007/s00405-018-4946-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Accepted: 03/20/2018] [Indexed: 02/07/2023]
Abstract
Purpose In this prospective clinical pilot study, abutments with different topologies (machined versus polished) were compared with respect to the clinical outcome and the microbiological profile. Furthermore, three different sampling methods (retrieval of abutment, collection of peri-abutment exudate using paper-points, and a small peri-abutment soft-tissue biopsy) were evaluated for the identification and quantification of colonising bacteria. Methods Twelve patients, seven with machined abutment and five with polished abutment, were included in the analysis. Three different sampling procedures were employed for the identification and quantification of colonising bacteria from baseline up to 12 months, using quantitative culturing. Clinical outcome measures (Holgers score, hygiene, pain, numbness and implant stability) were investigated. Results The clinical parameters, and total viable bacteria per abutment or in tissue biopsies did not differ significantly between the polished and machined abutments. The total CFU/mm2 abutment and CFU/peri-abutment fluid space of anaerobes, aerobes and staphylococci were significantly higher for the polished abutment. Anaerobic bacteria were detected in the tissue biopsies before BAHS implantation. Anaerobes and Staphylococcus spp. were detected in all three compartments after BAHS installation. For most patients (10/12), the same staphylococcal species were found in at least two of the three compartments at the same time-point. The common skin coloniser Staphylococcus epidermidis was identified in all patients but one (11/12), whereas the pathogen Staphylococcus aureus was isolated in five of the patients. Several associations between clinical and microbiological parameters were found. Conclusions There was no difference in the clinical outcome with the use of polished versus machined abutment at 3 and 12 months after implantation. The present pilot trial largely confirmed a suitable study design, sampling and analytical methodology to determine the effects of modified BAHS abutment properties. Level of evidence 2. Controlled prospective comparative study. Electronic supplementary material The online version of this article (10.1007/s00405-018-4946-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Margarita Trobos
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, P.O. Box 412, 405 30, Gothenburg, Sweden.
| | - Martin Lars Johansson
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, P.O. Box 412, 405 30, Gothenburg, Sweden
- Oticon Medical AB, Askim, Sweden
| | | | | | - Maria Hoffman
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, P.O. Box 412, 405 30, Gothenburg, Sweden
| | - Omar Omar
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, P.O. Box 412, 405 30, Gothenburg, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, P.O. Box 412, 405 30, Gothenburg, Sweden
| | - Malou Hultcrantz
- Department of Otorhinolaryngology, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
44
|
Song W, Yang C, Svend Le DQ, Zhang Y, Kjems J. Calcium-MicroRNA Complex-Functionalized Nanotubular Implant Surface for Highly Efficient Transfection and Enhanced Osteogenesis of Mesenchymal Stem Cells. ACS APPLIED MATERIALS & INTERFACES 2018; 10:7756-7764. [PMID: 29420881 DOI: 10.1021/acsami.7b18289] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Controlling mesenchymal stem cell (MSC) differentiation by RNA interference (RNAi) is a promising approach for next-generation regenerative medicine. However, efficient delivery of RNAi therapeutics is still a limiting factor. In this study, we have developed a simple, biocompatible, and highly effective delivery method of small RNA therapeutics into human MSCs (hMSCs) from an implant surface by calcium ions. First, we demonstrated that simple Ca/siRNA targeting green fluorescent protein (GFP) nanocomplexes were able to efficiently silence GFP in GFP-expressing hMSCs with adequate Ca2+ concentration (>5 mM). In addition, a single transfection could obtain a long-lasting silencing effect for more than 2 weeks. All three of the main endocytosis pathways (clathrin- and caveolin-mediated endocytosis and macropinocytosis) were involved in the internalization of the Ca/siRNA complexes by MSCs, and macropinocytosis plays the most dominant role. Furthermore, the Ca/siRNA complexes could be efficiently loaded onto the titanium implant surface when pretreated with anodization to create a nanotube (NT) layer. Because of the hydrophilic property of the NT surface, the Ca/siRNA was quickly loaded (less than 4 h) with high efficiency (nearly 100%), forming an even amorphous coating. The Ca/siRNA-coated NT surface showed an initial burst release of 80% of the siRNA complexes over 2 h, which is adequate to achieve robust gene silencing of attached hMSCs. To demonstrate the therapeutic potential of our Ca/siRNA coating technology, Ca/antimiR-138 complexes were loaded on to the NT surface, which strongly enhanced the osteogenic differentiation of hMSCs. In conclusion, our findings suggest that Ca2+ is an effective and biocompatible carrier to deliver small RNA therapeutics into hMSCs, both in solution and from functionalized surfaces, which provides a novel approach to control the MSC differentiation and tissue regeneration.
Collapse
Affiliation(s)
- Wen Song
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology , The Fourth Military Medical University , Xi'an 710032 , China
| | | | | | - Yumei Zhang
- State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Prosthodontics, School of Stomatology , The Fourth Military Medical University , Xi'an 710032 , China
| | | |
Collapse
|
45
|
Park KS, Al Awamleh AGI, Cho SA. Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias. J Adv Prosthodont 2018; 10:73-78. [PMID: 29503717 PMCID: PMC5829290 DOI: 10.4047/jap.2018.10.1.73] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 09/01/2017] [Accepted: 09/12/2017] [Indexed: 11/15/2022] Open
Abstract
PURPOSE The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS The mean RTQs were 12.29 ± 0.830 and 12.19 ± 0.713 Ncm after 7 days (P=.928) and 16.47 ± 1.324 and 16.17 ± 1.165 Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were 40 µm and consisted of numerous small pores, whereas pore sizes in the modSLA were 5 µm. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically.
Collapse
Affiliation(s)
- Kyung-Soon Park
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | | | - Sung-Am Cho
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| |
Collapse
|
46
|
Göthberg C, Gröndahl K, Omar O, Thomsen P, Slotte C. Bone and soft tissue outcomes, risk factors, and complications of implant-supported prostheses: 5-Years RCT with different abutment types and loading protocols. Clin Implant Dent Relat Res 2018; 20:313-321. [DOI: 10.1111/cid.12587] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Revised: 12/01/2017] [Accepted: 01/04/2018] [Indexed: 01/15/2023]
Affiliation(s)
- Catharina Göthberg
- Department of Prosthetic Dentistry; Institute for Postgraduate Dental Education; Jönköping Sweden
- Department of Biomaterials; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Gothenburg Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy; Gothenburg Sweden
| | - Kerstin Gröndahl
- Department of Oral & Maxillofacial Radiology; Institute for Postgraduate Dental Education; Jönköping Sweden
| | - Omar Omar
- Department of Biomaterials; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Gothenburg Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy; Gothenburg Sweden
| | - Peter Thomsen
- Department of Biomaterials; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Gothenburg Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy; Gothenburg Sweden
| | - Christer Slotte
- Department of Biomaterials; Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Gothenburg Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy; Gothenburg Sweden
- Department of Periodontology; Institute for Postgraduate Dental Education; Jönköping Sweden
| |
Collapse
|
47
|
Kruyt I, Banga R, Banerjee A, Mylanus E, Hol M. Clinical evaluation of a new laser-ablated titanium implant for bone-anchored hearing in 34 patients: 1-year experience. Clin Otolaryngol 2018; 43:761-764. [DOI: 10.1111/coa.13060] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/22/2017] [Indexed: 11/27/2022]
Affiliation(s)
- I.J. Kruyt
- Department of Otorhinolaryngology; Donders Center for Neurosciences; Radboud University Medical Centre; Nijmegen The Netherlands
| | - R. Banga
- Department of Otorhinolaryngology; Queen Elizabeth Hospital; Birmingham UK
| | - A. Banerjee
- Department of Otorhinolaryngology; James Cook University Hospital; Middlesbrough UK
| | - E.A.M. Mylanus
- Department of Otorhinolaryngology; Donders Center for Neurosciences; Radboud University Medical Centre; Nijmegen The Netherlands
| | - M.K.S. Hol
- Department of Otorhinolaryngology; Donders Center for Neurosciences; Radboud University Medical Centre; Nijmegen The Netherlands
| |
Collapse
|
48
|
Wang Z, Zhou R, Wen F, Zhang R, Ren L, Teoh SH, Hong M. Reliable laser fabrication: the quest for responsive biomaterials surface. J Mater Chem B 2018; 6:3612-3631. [DOI: 10.1039/c7tb02545a] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
This review presents current efforts in laser fabrication, focusing on the surface features of biomaterials and their biological responses; this provides insight into the engineering of bio-responsive surfaces for future medical devices.
Collapse
Affiliation(s)
- Zuyong Wang
- College of Materials Science and Engineering
- Hunan University
- Changsha 410082
- P. R. China
| | - Rui Zhou
- School of Aerospace Engineering
- Xiamen University
- Xiamen 361005
- P. R. China
| | - Feng Wen
- School of Chemical and Biomedical Engineering
- Nanyang Technological University
- Singapore 637457
- Singapore
| | - Rongkai Zhang
- The Third Affiliated Hospital of Southern Medical University
- Guangzhou 510630
- P. R. China
| | - Lei Ren
- College of Materials Science
- Xiamen University
- Xiamen 361005
- P. R. China
| | - Swee Hin Teoh
- College of Materials Science and Engineering
- Hunan University
- Changsha 410082
- P. R. China
- School of Chemical and Biomedical Engineering
| | - Minghui Hong
- School of Aerospace Engineering
- Xiamen University
- Xiamen 361005
- P. R. China
- Department of Electrical and Computer Engineering
| |
Collapse
|
49
|
Shah FA, Palmquist A. Evidence that Osteocytes in Autogenous Bone Fragments can Repair Disrupted Canalicular Networks and Connect with Osteocytes in de novo Formed Bone on the Fragment Surface. Calcif Tissue Int 2017; 101:321-327. [PMID: 28492981 PMCID: PMC5544810 DOI: 10.1007/s00223-017-0283-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Accepted: 04/20/2017] [Indexed: 01/28/2023]
Abstract
Autogenous bone fragments generated during surgery (e.g. implant site preparation) accelerate bone formation by the release of a large variety of growth factors from the extracellular matrix and the cells contained within. Osteocytes, whether viable or apoptotic, within such fragments are able to recruit osteoclasts to a site of bone remodelling. Here, using correlative scanning electron microscopy, we provide compelling evidence that at one week healing in the Sprague Dawley rat tibia, following surgery (and/or the placement of a bone-anchored implant), autogenous bone fragments support bone formation on their surface. Furthermore, osteocytes within the autogenous fragments are frequently able to repair the disrupted canalicular networks and appear to connect with osteocytes (or osteoblastic-osteocytes) in the de novo formed bone on the surface of the fragment.
Collapse
Affiliation(s)
- Furqan A Shah
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Göteborg, Sweden.
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Göteborg, Sweden.
| | - Anders Palmquist
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Göteborg, Sweden
| |
Collapse
|
50
|
Sayardoust S, Omar O, Norderyd O, Thomsen P. Clinical, radiological, and gene expression analyses in smokers and non-smokers, Part 2: RCT on the late healing phase of osseointegration. Clin Implant Dent Relat Res 2017; 19:901-915. [PMID: 28744993 DOI: 10.1111/cid.12514] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2017] [Revised: 06/21/2017] [Accepted: 06/23/2017] [Indexed: 12/18/2022]
Abstract
BACKGROUND The mechanisms behind the impact of smoking on osseointegration are not fully understood. PURPOSE To investigate the initial clinical and molecular course of osseointegration of different implants in smokers and non-smokers in a randomized controlled trial (RCT). MATERIALS AND METHODS Smoking (n = 16) and non-smoking (n = 16) patients received 3 implant types: machined, oxidized, and laser-modified surfaces. Baseline bone biopsies were retrieved from the implant sites. After 60 and 90 days, the pain score, implant stability quotient (ISQ), and peri-implant crevicular fluid (PICF) gene expression were analyzed. Furthermore, radiological and clinical assessments were made at 90 days. RESULTS At 90 days, no pain was reported, irrespective of smoking habit. A higher ISQ was found in smokers compared with non-smokers. Marginal bone loss (MBL) was greater in smokers than in non-smokers. The comparison of implant surfaces revealed greater MBL exclusively at the machined implants in smokers. At 90 days in smokers, the PICF around machined implants revealed a higher expression of the proinflammatory cytokine, interleukin-6 (IL-6), and a lower expression of the osteogenic gene, osteocalcin (OC), compared with the PICF around modified implants. Furthermore, OC expression was lower at machined implants in smokers compared with machined implants in non-smokers. After adjustment for age and implant location (maxilla/mandible), multivariate regression revealed the following predictors of MBL: smoking, bleeding on probing at 90 days, hypoxia-inducible factor 1 alpha (HIF-1α) expression at baseline and IL-6 expression in PICF at 90 days. CONCLUSIONS During the early phase of osseointegration, non-smokers and smokers present a similar, high implant survival. In contrast, smokers present a greater MBL, particularly at machined implants. HIF-1α baseline expression in the recipient bone and IL-6 expression in PICF cells are important molecular determinants for MBL after 90 days. It is concluded that smoking has an early effect on osseointegration, which is dependent on the implant surface properties and the local host response.
Collapse
Affiliation(s)
- Shariel Sayardoust
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.,Department of Periodontology, Institute for Postgraduate Dental Education, Jönköping, Sweden
| | - Omar Omar
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
| | - Ola Norderyd
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.,Department of Periodontology, Institute for Postgraduate Dental Education, Jönköping, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden
| |
Collapse
|