1
|
Awawdeh K, Buttkewitz MA, Bahnemann J, Segal E. Enhancing the performance of porous silicon biosensors: the interplay of nanostructure design and microfluidic integration. MICROSYSTEMS & NANOENGINEERING 2024; 10:100. [PMID: 39021530 PMCID: PMC11252414 DOI: 10.1038/s41378-024-00738-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 06/08/2024] [Accepted: 06/12/2024] [Indexed: 07/20/2024]
Abstract
This work presents the development and design of aptasensor employing porous silicon (PSi) Fabry‒Pérot thin films that are suitable for use as optical transducers for the detection of lactoferrin (LF), which is a protein biomarker secreted at elevated levels during gastrointestinal (GI) inflammatory disorders such as inflammatory bowel disease and chronic pancreatitis. To overcome the primary limitation associated with PSi biosensors-namely, their relatively poor sensitivity due to issues related to complex mass transfer phenomena and reaction kinetics-we employed two strategic approaches: First, we sought to optimize the porous nanostructure with respect to factors including layer thickness, pore diameter, and capture probe density. Second, we leveraged convection properties by integrating the resulting biosensor into a 3D-printed microfluidic system that also had one of two different micromixer architectures (i.e., staggered herringbone micromixers or microimpellers) embedded. We demonstrated that tailoring the PSi aptasensor significantly improved its performance, achieving a limit of detection (LOD) of 50 nM-which is >1 order of magnitude lower than that achieved using previously-developed biosensors of this type. Moreover, integration into microfluidic systems that incorporated passive and active micromixers further enhanced the aptasensor's sensitivity, achieving an additional reduction in the LOD by yet another order of magnitude. These advancements demonstrate the potential of combining PSi-based optical transducers with microfluidic technology to create sensitive label-free biosensing platforms for the detection of GI inflammatory biomarkers.
Collapse
Affiliation(s)
- Kayan Awawdeh
- Faculty of Biotechnology and Food Engineering, Technion—Israel Institute of Technology, 320003 Haifa, Israel
| | - Marc A. Buttkewitz
- Institute of Technical Chemistry, Leibniz Universität Hannover, 30167 Hannover, Germany
| | - Janina Bahnemann
- Institute of Physics, University of Augsburg, 86159 Augsburg, Germany
- Centre for Advanced Analytics and Predictive Sciences (CAAPS), University of Augsburg, 86159 Augsburg, Germany
| | - Ester Segal
- Faculty of Biotechnology and Food Engineering, Technion—Israel Institute of Technology, 320003 Haifa, Israel
| |
Collapse
|
2
|
Hashimoto S, Matsuo K. Dynamic Observation of the Membrane Interaction Processes of β-Lactoglobulin by Time-Resolved Vacuum-Ultraviolet Circular Dichroism. Anal Chem 2024; 96:10524-10533. [PMID: 38907695 DOI: 10.1021/acs.analchem.4c00556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/24/2024]
Abstract
The elucidation of protein-membrane interactions is pivotal for comprehending the mechanisms underlying diverse biological phenomena and membrane-related diseases. In this investigation, vacuum-ultraviolet circular dichroism (VUVCD) spectroscopy, utilizing synchrotron radiation (SR), was employed to dynamically observe membrane interaction processes involving water-soluble proteins at the secondary-structure level. The study utilized a time-resolved (TR) T-shaped microfluidic cell, facilitating the rapid and efficient mixing of protein and membrane solutions. This system was instrumental in acquiring measurements of the time-resolved circular dichroism (TRCD) spectra of β-lactoglobulin (bLG) during its interaction with lysoDMPG micelles. The results indicate that bLG undergoes a β-α conformation change, leading to the formation of the membrane-interacting state (M-state), with structural alterations occurring in more than two steps. Global fitting analysis, employing biexponential functions with all of the TRCD spectral data sets, yielded two distinct rate constants (0.18 ± 0.01 and 0.06 ± 0.003/s) and revealed a unique spectrum corresponding to an intermediate state (I-state). Secondary-structure analysis of bLG in its native (N-, I-, and M-states) highlighted that structural changes from the N- to I-states predominantly occurred in the N- and C-terminal regions, which were prominently exposed to the membrane. Meanwhile, transitions from the I- to M-states extended into the inner barrel regions of bLG. Further examination of the physical properties of α-helical segments, such as effective charge and hydrophobicity, revealed that the N- to I- and I- to M-state transitions, which are ascribed to first- and second-rate constants, respectively, are primarily driven by electrostatic and hydrophobic interactions, respectively. These findings underscore the capability of the TR-VUVCD system as a robust tool for characterizing protein-membrane interactions at the molecular level.
Collapse
Affiliation(s)
- Satoshi Hashimoto
- Graduate School of Advanced Science and Engineering, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima 739-8526, Japan
| | - Koichi Matsuo
- Graduate School of Advanced Science and Engineering, Hiroshima University, 1-3-1 Kagamiyama, Higashi-Hiroshima 739-8526, Japan
- Research Institute for Synchrotron Radiation Science, Hiroshima University, 2-313 Kagamiyama, Higashi-Hiroshima 739-0046, Japan
- International Institute for Sustainability with Knotted Chiral Meta Matter (WPI-SKCM2), Hiroshima University, 2-313 Kagamiyama, Higashi-Hiroshima 739-0046, Japan
| |
Collapse
|
3
|
Misra B, Hughes KA, Pentz WH, Samart P, Geldenhuys WJ, Bobbala S. Flash nanoprecipitation assisted self-assembly of ionizable lipid nanoparticles for nucleic acid delivery. NANOSCALE 2024; 16:6939-6948. [PMID: 38511623 PMCID: PMC11040450 DOI: 10.1039/d4nr00278d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/22/2024]
Abstract
Ionizable lipid nanoparticles (LNPs) have emerged as a powerful tool for the intracellular delivery of nucleic acids. Following the recent success of LNP-based siRNA therapeutics and mRNA vaccines, the use of ionizable lipids for nucleic acid delivery has tremendously increased. Here, we introduce a flash nanoprecipitation (FNP) approach using the confined impingement (CIJ) mixer to stably self-assemble ionizable LNPs. To validate this approach, we employed three clinically relevant LNP formulations containing SM102, ALC0315, and DLin-MC3-DMA as ionizable lipids. FNP-assembled LNPs showed >95% encapsulation efficiency of mRNA and siRNA payloads and particle sizes below 150 nm. SM102 or ALC0315 LNPs demonstrated efficient delivery of mRNA into immune cells in vitro and to lymphoid organs in vivo, whereas Dlin-MC3-DMA LNPs allowed effective intracellular siRNA delivery with great functional ability. The FNP technique could economically produce LNPs in smaller volumes that are highly suitable for the discovery phase.
Collapse
Affiliation(s)
- Bishal Misra
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV, USA.
| | - Krystal A Hughes
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV, USA.
| | - William H Pentz
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV, USA.
- School of Medicine, West Virginia University, Morgantown, WV 26506, USA
| | - Parinya Samart
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV, USA.
| | - Werner J Geldenhuys
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV, USA.
| | - Sharan Bobbala
- Department of Pharmaceutical Sciences, West Virginia University, Morgantown, WV, USA.
| |
Collapse
|
4
|
Bowman CE. Looking for future biological control agents: the comparative function of the deutosternal groove in mesostigmatid mites. EXPERIMENTAL & APPLIED ACAROLOGY 2023; 91:139-235. [PMID: 37676375 PMCID: PMC10562343 DOI: 10.1007/s10493-023-00832-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2023] [Accepted: 07/31/2023] [Indexed: 09/08/2023]
Abstract
The physics of fluid laminar flow through an idealised deutosternum assembly is used for the first time to review predatory feeding designs over 72 different-sized example species from 16 mesostigmatid families in order to inform the finding of new biological control agents. Gnathosomal data are digitised from published sources. Relevant gnathosomal macro- and micro-features are compared and contrasted in detail which may subtly impact the control of channel- or 'pipe'-based transport of prey liquids around various gnathosomal locations. Relative deutosternal groove width on the mesostigmatid subcapitulum is important but appears unrelated to the closing velocity ratio of the moveable digit. Big mites are adapted for handling large and watery prey. The repeated regular distance between deutosternal transverse ridges ('Querleisten') supports the idea of them enabling a regular fluctuating bulging or pulsing droplet-based fluid wave 'sticking' and 'slipping' along the groove. Phytoseiids are an outlier functional group with a low deutosternal pipe flow per body size designed for slot-like microchannel transport in low volume fluid threads arising from daintily nibbling nearby prey klinorhynchidly. Deutosternal groove denticles are orientated topographically in order to synergise flow and possible mixing of coxal gland-derived droplets and circumcapitular reservoir fluids across the venter of the gnathosomal base back via the hypostome to the prey being masticated by the chelicerae. As well as working with the tritosternum to mechanically clean the deutosternum, denticles may suppress fluid drag. Shallow grooves may support edge-crawling viscous flow. Lateral features may facilitate handling unusual amounts of fluid arising from opportunistic feeding on atypical prey. Various conjectures for confirmatory follow-up are highlighted. Suggestions as to how to triage non-uropodoid species as candidate plant pest control agents are included.
Collapse
Affiliation(s)
- Clive E Bowman
- Mathematical Institute, University of Oxford, Oxford, OX2 6GG, UK.
| |
Collapse
|
5
|
Pysz PM, Hoskins JK, Zou M, Stenken JA. 3D Printed Customizable Microsampling Devices for Neuroscience Applications. ACS Chem Neurosci 2023; 14:3278-3287. [PMID: 37646856 DOI: 10.1021/acschemneuro.3c00166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023] Open
Abstract
Multifunctional devices that incorporate chemical or physical measurements combined with ways to manipulate brain tissue via drug delivery, electrical stimulation, or light for optogenetics are desired by neuroscientists. The next generation in vivo brain devices will likely utilize the extensive flexibility and rapid processing of 3D printing. This Perspective demonstrates how close we are to this reality for advanced neuroscience measurements. 3D printing provides the opportunity to improve microsampling-based devices in ways that have not been previously available. Not only can 3D printing be used for actual device creation, but it can also allow printing of peripheral objects necessary to assemble functional devices. The most probable 3D printing set up for microsampling devices with appropriate nm to μm feature size will likely require 2-photon polymerization-based printers. This Perspective describes the advantages and challenges for 3D printing of microsampling devices as an initial step to meet the next generation device needs of neuroscientists.
Collapse
Affiliation(s)
- Patrick M Pysz
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, Arkansas 72701, United States
- Materials Science and Engineering Program, University of Arkansas, Fayetteville, Arkansas 72701, United States
| | - Julia K Hoskins
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, United States
- Center for Advanced Surface Engineering, University of Arkansas, Fayetteville, Arkansas 72701, United States
| | - Min Zou
- Materials Science and Engineering Program, University of Arkansas, Fayetteville, Arkansas 72701, United States
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, Arkansas 72701, United States
- Center for Advanced Surface Engineering, University of Arkansas, Fayetteville, Arkansas 72701, United States
| | - Julie A Stenken
- Department of Chemistry and Biochemistry, University of Arkansas, Fayetteville, Arkansas 72701, United States
- Materials Science and Engineering Program, University of Arkansas, Fayetteville, Arkansas 72701, United States
| |
Collapse
|
6
|
Milton LA, Viglione MS, Ong LJY, Nordin GP, Toh YC. Vat photopolymerization 3D printed microfluidic devices for organ-on-a-chip applications. LAB ON A CHIP 2023; 23:3537-3560. [PMID: 37476860 PMCID: PMC10448871 DOI: 10.1039/d3lc00094j] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/22/2023]
Abstract
Organs-on-a-chip, or OoCs, are microfluidic tissue culture devices with micro-scaled architectures that repeatedly achieve biomimicry of biological phenomena. They are well positioned to become the primary pre-clinical testing modality as they possess high translational value. Current methods of fabrication have facilitated the development of many custom OoCs that have generated promising results. However, the reliance on microfabrication and soft lithographic fabrication techniques has limited their prototyping turnover rate and scalability. Additive manufacturing, known commonly as 3D printing, shows promise to expedite this prototyping process, while also making fabrication easier and more reproducible. We briefly introduce common 3D printing modalities before identifying two sub-types of vat photopolymerization - stereolithography (SLA) and digital light processing (DLP) - as the most advantageous fabrication methods for the future of OoC development. We then outline the motivations for shifting to 3D printing, the requirements for 3D printed OoCs to be competitive with the current state of the art, and several considerations for achieving successful 3D printed OoC devices touching on design and fabrication techniques, including a survey of commercial and custom 3D printers and resins. In all, we aim to form a guide for the end-user to facilitate the in-house generation of 3D printed OoCs, along with the future translation of these important devices.
Collapse
Affiliation(s)
- Laura A Milton
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia
| | - Matthew S Viglione
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, Utah, USA.
| | - Louis Jun Ye Ong
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia
- Max Planck Queensland Centre (MPQC) for the Materials Science of Extracellular Matrices, Queensland University of Technology, Brisbane, Australia
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, Brigham Young University, Provo, Utah, USA.
| | - Yi-Chin Toh
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, Australia.
- Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, Australia
- Max Planck Queensland Centre (MPQC) for the Materials Science of Extracellular Matrices, Queensland University of Technology, Brisbane, Australia
- Centre for Microbiome Research, Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
7
|
Downs BM, Hoang TM, Cope L. Increasing the Capture Rate of Circulating Tumor DNA in Unaltered Plasma Using Passive Microfluidic Mixer Flow Cells. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2023; 39:3225-3234. [PMID: 36811956 DOI: 10.1021/acs.langmuir.2c02919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
A limiting factor in using blood-based liquid biopsies for cancer detection is the volume of extracted blood required to capture a measurable number of circulating tumor DNA (ctDNA). To overcome this limitation, we developed a technology named the dCas9 capture system to capture ctDNA from unaltered flowing plasma, removing the need to extract the plasma from the body. This technology has provided the first opportunity to investigate whether microfluidic flow cell design can affect the capture of ctDNA in unaltered plasma. With inspiration from microfluidic mixer flow cells designed to capture circulating tumor cells and exosomes, we constructed four microfluidic mixer flow cells. Next, we investigated the effects of these flow cell designs and the flow rate on the rate of captured spiked-in BRAF T1799A (BRAFMut) ctDNA in unaltered flowing plasma using surface-immobilized dCas9. Once the optimal mass transfer rate of ctDNA, identified by the optimal ctDNA capture rate, was determined, we investigated whether the design of the microfluidic device, flow rate, flow time, and the number of spiked-in mutant DNA copies affected the rate of capture by the dCas9 capture system. We found that size modifications to the flow channel had no effect on the flow rate required to achieve the optimal capture rate of ctDNA. However, decreasing the size of the capture chamber decreased the flow rate required to achieve the optimal capture rate. Finally, we showed that, at the optimal capture rate, different microfluidic designs using different flow rates could capture DNA copies at a similar rate over time. In this study, the optimal capture rate of ctDNA in unaltered plasma was identified by adjusting the flow rate in each of the passive microfluidic mixer flow cells. However, further validation and optimization of the dCas9 capture system are required before it is ready to be used clinically.
Collapse
Affiliation(s)
- Bradley M Downs
- Department of Oncology, The Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231, United States
| | - Tra-My Hoang
- Department of Pharmaceutical Sciences, School of Pharmacy, University of Maryland, Baltimore, Maryland 21201, United States
| | - Leslie Cope
- Department of Oncology, The Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, Maryland 21231, United States
| |
Collapse
|
8
|
Comparative application of microfluidic systems in circulating tumor cells and extracellular vesicles isolation; a review. Biomed Microdevices 2022; 25:4. [PMID: 36574057 DOI: 10.1007/s10544-022-00644-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/14/2022] [Indexed: 12/28/2022]
Abstract
Cancer is a prevalent cause of mortality globally, where early diagnosis leads to a reduced death rate. Many researchers' common strategies are based on personalized diagnostic methods with rapid response and high accuracy. This technology was developed by applying liquid biopsy instead of tissue biopsies in the case of tumor cell analysis that facilitates point-of-care testing for cancer diagnosis and treatment. In recent years, significant progress in microfluidic technology led to the successful isolation, analysis, and monitoring of cancer biomarkers in body liquid biopsy with merits like high sensitivity and flexibility, low sample usage, cost effective, and the ability of automation. The most critical and informative markers in body liquid refer to circulating tumor cells (CTCs) and extracellular vesicles derived from tumors (EVs) that carry various biomarkers in their structure (DNAs, proteins, and RNAs) as compared to ctDNA. The released ctDNA has a low half-life and decreased sensitivity due to large amounts of nucleic acid in serum. This review intends to highlight different cancer screening tests with a particular focus on the details regarding the only FDA-approved and awaiting technologies for FDA clearance to isolate CTCs and EVs based on microfluidics systems.
Collapse
|
9
|
Numerical and experimental analysis of effective passive mixing via a 3D serpentine channel. Chem Eng Sci 2022. [DOI: 10.1016/j.ces.2022.117972] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
10
|
Li W, Chaihu L, Jiang J, Wu B, Zheng X, Dai R, Tian Y, Huang Y, Wang G, Men Y. Microfluidic Platform for Time-Resolved Characterization of Protein Higher-Order Structures and Dynamics Using Top-Down Mass Spectrometry. Anal Chem 2022; 94:7520-7527. [PMID: 35584038 DOI: 10.1021/acs.analchem.2c00077] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Characterization of protein higher-order structures and dynamics is essential for understanding the biological functions of proteins and revealing the underlying mechanisms. Top-down mass spectrometry (MS) accesses structural information at both the intact protein level and the peptide fragment level. Native top-down MS allows analysis of a protein complex's architecture and subunits' identity and modifications. Top-down hydrogen/deuterium exchange (HDX) MS offers high spatial resolution for conformational or binding interface analysis and enables conformer-specific characterization. A microfluidic chip can provide superior performance for front-end reactions useful for these MS workflows, such as flexibility in manipulating multiple reactant flows, integrating various functional modules, and automation. However, most microchip-MS devices are designed for bottom-up approaches or top-down proteomics. Here, we demonstrate a strategy for designing a microchip for top-down MS analysis of protein higher-order structures and dynamics. It is suitable for time-resolved native MS and HDX MS, with designs aiming for efficient ionization of intact protein complexes, flexible manipulation of multiple reactant flows, and precise control of reaction times over a broad range of flow rates on the submicroliter per minute scale. The performance of the prototype device is demonstrated by measurements of systems including monoclonal antibodies, antibody-antigen complexes, and coexisting protein conformers. This strategy may benefit elaborate structural analysis of biomacromolecules and inspire method development using the microchip-MS approach.
Collapse
Affiliation(s)
- Wen Li
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Lingxiao Chaihu
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China.,Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Jialu Jiang
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Bizhu Wu
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Xuan Zheng
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Rongrong Dai
- School of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China
| | - Ye Tian
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Yanyi Huang
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China.,Biomedical Pioneering Innovation Centre, Peking University, Beijing 100871, China
| | - Guanbo Wang
- Institute of Cell Analysis, Shenzhen Bay Laboratory, Shenzhen 518132, China.,Biomedical Pioneering Innovation Centre, Peking University, Beijing 100871, China
| | - Yongfan Men
- Research Center for Biomedical Optics and Molecular Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| |
Collapse
|
11
|
Liao Y, Mechulam Y, Lassalle-Kaiser B. A millisecond passive micromixer with low flow rate, low sample consumption and easy fabrication. Sci Rep 2021; 11:20119. [PMID: 34635693 PMCID: PMC8505571 DOI: 10.1038/s41598-021-99471-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/17/2021] [Indexed: 11/30/2022] Open
Abstract
Fast mixing of small volumes of solutions in microfluidic devices is essential for an accurate control and observation of the dynamics of a reaction in biological or chemical studies. It is often, however, a challenging task, as the Reynolds number (Re) in microscopic devices is typically < 100. In this report, we detail a novel mixer based on the “staggered herring bone” (SHB) pattern and “split-recombination” strategies with an optimized geometry, the periodic rotation of the flow structure can be controlled and recombined in a way that the vortices and phase shifts of the flow induce intertwined lamellar structures, thus increasing the contact surface and enhancing mixing. The optimization improves the mixing while using a low flow rate, hence a small volume for mixing and moderate pressure drops. The performances of the patterns were first simulated using COMSOL Multiphysics under different operating conditions. The simulation indicates that at very low flow rate (1–12 µL·min−1) and Re (3.3–40), as well as a very small working volume (~ 3 nL), a very good mixing (~ 98%) can be achieved in the ms time range (4.5–78 ms). The most promising design was then visualized experimentally, showing results that are consistent with the outcomes of the simulations. Importantly, the devices were fabricated using a classical soft-lithography method, as opposed to additive manufacturing often used to generate complex mixing structures. This new device minimizes the sample consumption and could therefore be applied for studies using precious samples.
Collapse
Affiliation(s)
- Yuanyuan Liao
- Synchrotron SOLEIL, l'Orme des Merisiers, 91192, Gif-sur-Yvette, France. .,IamFluidics BV, High Tech Factory, De Veldmaat 17, 7522 NM, Enschede, The Netherlands.
| | - Yves Mechulam
- Laboratoire de Biologie Structurale de la Cellule, BIOC, Ecole Polytechnique, CNRS, Institut Polytechnique de Paris, 91128, Palaiseau Cedex, France
| | | |
Collapse
|
12
|
Zeraatkar M, de Tullio MD, Percoco G. Fused Filament Fabrication (FFF) for Manufacturing of Microfluidic Micromixers: An Experimental Study on the Effect of Process Variables in Printed Microfluidic Micromixers. MICROMACHINES 2021; 12:mi12080858. [PMID: 34442481 PMCID: PMC8399612 DOI: 10.3390/mi12080858] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 07/16/2021] [Accepted: 07/19/2021] [Indexed: 12/13/2022]
Abstract
The need for accessible and inexpensive microfluidic devices requires new manufacturing methods and materials as a replacement for traditional soft lithography and polydimethylsiloxane (PDMS). Recently, with the advent of modern additive manufacturing (AM) techniques, 3D printing has attracted attention for its use in the fabrication of microfluidic devices and due to its automated, assembly-free 3D fabrication, rapidly decreasing cost, and fast-improving resolution and throughput. Here, fused filament fabrication (FFF) 3D printing was used to create microfluidic micromixers and enhance the mixing process, which has been identified as a challenge in microfluidic devices. A design of experiment (DoE) was performed on the effects of studied parameters in devices that were printed by FFF. The results of the colorimetric approach showed the effects of different parameters on the mixing process and on the enhancement of the mixing performance in printed devices. The presence of the geometrical features on the microchannels can act as ridges due to the nature of the FFF process. In comparison to passive and active methods, no complexity was added in the fabrication process, and the ridges are an inherent property of the FFF process.
Collapse
|
13
|
A single snapshot multiplex immunoassay platform utilizing dense test lines based on engineered beads. Biosens Bioelectron 2021; 190:113388. [PMID: 34098362 PMCID: PMC8166042 DOI: 10.1016/j.bios.2021.113388] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 05/17/2021] [Accepted: 05/28/2021] [Indexed: 12/23/2022]
Abstract
Co-circulation of coronavirus disease 2019 (COVID-19) and dengue fever has been reported. Accurate and timely multiplex diagnosis is required to prevent future pandemics. Here, we developed an innovative microfluidic chip that enables a snapshot multiplex immunoassay for timely on-site response and offers unprecedented multiplexing capability with an operating procedure similar to that of lateral flow assays. An open microchannel assembly of individually engineered microbeads was developed to construct nine high-density test lines, which can be imaged in a 1 mm2 field-of-view. Thus, simultaneous detection of multiple antibodies would be achievable in a single high-resolution snapshot. Next, we developed a novel pixel intensity-based imaging process to distinguish effective and non-specific fluorescence signals, thereby improving the reliability of this fluorescence-based immunoassay. Finally, the chip specifically identified and classified random combinations of arbovirus (Zika, dengue, and chikungunya viruses) and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibodies within 30 min. Therefore, we believe that this snapshot multiplex immunoassay chip is a powerful diagnostic tool to control current and future pandemics.
Collapse
|
14
|
Oevreeide IH, Zoellner A, Stokke BT. Characterization of Mixing Performance Induced by Double Curved Passive Mixing Structures in Microfluidic Channels. MICROMACHINES 2021; 12:mi12050556. [PMID: 34068289 PMCID: PMC8153322 DOI: 10.3390/mi12050556] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 05/11/2021] [Indexed: 12/11/2022]
Abstract
Functionalized sensor surfaces combined with microfluidic channels are becoming increasingly important in realizing efficient biosensing devices applicable to small sample volumes. Relaxing the limitations imposed by laminar flow of the microfluidic channels by passive mixing structures to enhance analyte mass transfer to the sensing area will further improve the performance of these devices. In this paper, we characterize the flow performance in a group of microfluidic flow channels with novel double curved passive mixing structures (DCMS) fabricated in the ceiling. The experimental strategy includes confocal imaging to monitor the stationary flow patterns downstream from the inlet where a fluorophore is included in one of the inlets in a Y-channel microfluidic device. Analyses of the fluorescence pattern projected both along the channel and transverse to the flow direction monitored details in the developing homogenization. The mixing index (MI) as a function of the channel length was found to be well accounted for by a double-exponential equilibration process, where the different parameters of the DCMS were found to affect the extent and length of the initial mixing component. The range of MI for a 1 cm channel length for the DCMS was 0.75–0.98, which is a range of MI comparable to micromixers with herringbone structures. Overall, this indicates that the DCMS is a high performing passive micromixer, but the sensitivity to geometric parameter values calls for the selection of certain values for the most efficient mixing.
Collapse
Affiliation(s)
- Ingrid H. Oevreeide
- Division of Biophysics and Medical Technology, Department of Physics, NTNU The Norwegian University of Science and Technology, NO-7491 Trondheim, Norway;
| | | | - Bjørn T. Stokke
- Division of Biophysics and Medical Technology, Department of Physics, NTNU The Norwegian University of Science and Technology, NO-7491 Trondheim, Norway;
- Correspondence:
| |
Collapse
|
15
|
Advances in microfluidic synthesis and coupling with synchrotron SAXS for continuous production and real-time structural characterization of nano-self-assemblies. Colloids Surf B Biointerfaces 2021; 201:111633. [PMID: 33639513 DOI: 10.1016/j.colsurfb.2021.111633] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2020] [Revised: 02/03/2021] [Accepted: 02/15/2021] [Indexed: 02/06/2023]
Abstract
Microfluidic platforms have become highly attractive tools for synthesis of nanoparticles, including lipid nano-self-assemblies, owing to unique features and at least three important aspects inherent to miniaturized micro-devices. Firstly, the fluids flow under controlled conditions in the microchannels, providing well-defined flow profiles and shorter diffusion lengths that play important roles in enhancing the continuous production of lipid and polymer nanoparticles with relatively narrow size distributions. Secondly, various geometries adapted to microfluidic device designs can be utilized for enhancing the colloidal stability of nanoparticles and improving their drug loading. Thirdly, microfluidic devices are usually compatible with in situ characterization methods for real-time monitoring of processes occurring inside the microchannels. This is unlike conventional nanoparticle synthesis methods, where a final solution or withdrawn aliquots are separately analysed. These features inherent to microfluidic devices provide a tool-set allowing not only precise nanoparticle size control, but also real-time analyses for process optimization. In this review, we focus on recent advances and developments in the use of microfluidic devices for synthesis of lipid nanoparticles. We present different designs based on hydrodynamic flow focusing, droplet-based methods and controlled microvortices, and discuss integration of microfluidic platforms with synchrotron small-angle X ray scattering (SAXS) for in situ structural characterization of lipid nano-self-assemblies under continuous flow conditions, along with major challenges and future directions in this research area.
Collapse
|
16
|
Kwak TJ, Lee E. In vitro modeling of solid tumor interactions with perfused blood vessels. Sci Rep 2020; 10:20142. [PMID: 33214583 PMCID: PMC7677310 DOI: 10.1038/s41598-020-77180-1] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 11/06/2020] [Indexed: 02/06/2023] Open
Abstract
Molecular crosstalk between intra-tumor blood vessels and tumor cells plays many critical roles in tumorigenesis and cancer metastasis. However, it has been very difficult to investigate the biochemical mechanisms underlying the overlapping, multifactorial processes that occur at the tumor-vascular interface using conventional murine models alone. Moreover, traditional two-dimensional (2D) culture models used in cancer research do not recapitulate aspects of the 3D tumor microenvironment. In the present study, we introduce a microfluidic model of the solid tumor-vascular interface composed of a human umbilical vein endothelial cell (HUVEC)-lined, perfusable, bioengineered blood vessel and tumor spheroids embedded in an extracellular matrix (ECM). We sought to optimize our model by varying the composition of the tumor spheroids (MDA-MB-231 breast tumor cells + mesenchymal stem cells (MSCs)/human lung fibroblasts (HLFs)/HUVECs) and the extracellular matrix (ECM: collagen, Matrigel, and fibrin gels with or without free HLFs) that we used. Our results indicate that culturing tumor spheroids containing MDA-MB-231 cells + HUVECs in an HLF-laden, fibrin-based ECM within our microfluidic device optimally (1) enhances the sprouting and migration of tumor spheroids, (2) promotes angiogenesis, (3) facilitates vascular invasion, and (4) preserves the structural integrity and functionality of HUVEC-lined microfluidic channels. This model may provide a platform for drug screening and mechanism studies on solid tumor interactions with functional blood vessels.
Collapse
Affiliation(s)
- Tae Joon Kwak
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA
| | - Esak Lee
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, 14853, USA.
| |
Collapse
|
17
|
Kwak TJ, Lee E. Rapid multilayer microfabrication for modeling organotropic metastasis in breast cancer. Biofabrication 2020; 13. [PMID: 32998119 DOI: 10.1088/1758-5090/abbd28] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 09/30/2020] [Indexed: 12/22/2022]
Abstract
Triple-negative breast cancer (TNBC) is one of the most insidious forms of breast cancer with high rates of metastasis, resulting in major mortalities in breast cancer patients. To better understand and treat TNBC metastasis, investigation of TNBC interactions with blood vasculatures is crucial. Among multiple metastatic processes, a step of TNBC exit from the blood vessels ('extravasation') in the pre-metastatic organs determines the final site of the metastasis. Here, we present a rapid multilayer microfabrication method of transferring a three-dimensional (3D) overhang pattern to a substrate with a sacrificial layer to reconstitute a 3D blood vessel surrounded by the extracellular matrix containing organ-specific parenchymal cells. Bones and lungs are the most common sites of breast cancer metastasis. We modeled organotropic bone and lung metastasis in TNBC by introducing subpopulations of TNBC metastases into a vessel lumen surrounded by osteoblasts, bone marrow derived mesenchymal stem cells, and lung fibroblasts. We found that bone-like microenviroment with osteoblasts and mesenchymal stem cells promoted extravasation of the bone-tropic TNBC cells, whereas the lung-like microenviroment promoted extravasation of the lung-tropic TNBC cells. Given that these organ-specific parenchymal cells do not impact vascular permeability, our results suggest that the parenchymal cells dictate selective extravasation of the bone-tropic or lung-tropic TNBC cells in our system.
Collapse
Affiliation(s)
- Tae Joon Kwak
- Biomedical Engineering, Cornell University, 309A Weill hall, Cornell University, Ithaca, Ithaca, New York, 14853, UNITED STATES
| | - Esak Lee
- Cornell University, Ithaca, New York, 14853-0001, UNITED STATES
| |
Collapse
|
18
|
Chen Y, Chen X, Liu S. Numerical investigations of a passive micromixer with tree shape obstacles based on fractal principle and Murray’s law. J DISPER SCI TECHNOL 2020. [DOI: 10.1080/01932691.2020.1770610] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Yao Chen
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| | - Xueye Chen
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| | - Shufen Liu
- Faculty of Mechanical Engineering and Automation, Liaoning University of Technology, Jinzhou, China
| |
Collapse
|
19
|
Abstract
An electronic tongue (e-tongue) is a multisensory system usually applied to complex liquid media that uses computational/statistical tools to group information generated by sensing units into recognition patterns, which allow the identification/distinction of samples. Different types of e-tongues have been previously reported, including microfluidic devices. In this context, the integration of passive mixers inside microchannels is of great interest for the study of suppression/enhancement of sensorial/chemical effects in the pharmaceutical, food, and beverage industries. In this study, we present developments using a stereolithography technique to fabricate microfluidic devices using 3D-printed molds for elastomers exploring the staggered herringbone passive mixer geometry. The fabricated devices (microchannels plus mixer) are then integrated into an e-tongue system composed of four sensing units assembled on a single printed circuit board (PCB). Gold-plated electrodes are designed as an integral part of the PCB electronic circuitry for a highly automated platform by enabling faster analysis and increasing the potential for future use in commercial applications. Following previous work, the e-tongue sensing units are built functionalizing gold electrodes with layer-by-layer (LbL) films. Our results show that the system is capable of (i) covering basic tastes below the human gustative perception and (ii) distinguishing different suppression effects coming from the mixture of both strong and weak electrolytes. This setup allows for triplicate measurements in 12 electrodes, which represents four complete sensing units, by automatically switching all electrodes without any physical interaction with the sensor. The result is a fast and reliable data acquisition system, which comprises a suitable solution for monitoring, sequential measurements, and database formation, being less susceptible to human errors.
Collapse
|
20
|
Rampalli S, Dundi TM, Chandrasekhar S, Raju VRK, Chandramohan VP. Numerical Evaluation of Liquid Mixing in a Serpentine Square Convergent-divergent Passive Micromixer. CHEMICAL PRODUCT AND PROCESS MODELING 2020. [DOI: 10.1515/cppm-2019-0071] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractMicromixers are crucial components to carry out chemical, biomedical and bio-chemical analyses on µTAS (micro total analysis system) or Lab-on-chips. Simple planar type passive mixers are always most desirable over three dimensional or complex geometries of passive mixers or active mixers as they are less expensive, easy to fabricate, and easy to integrate into complex miniaturized systems. However, at very low Reynolds numbers (0 to 100), due to the inherent laminar nature of the microfluidic flows, mixing remains challenging in passive mixers. Previous studies reported that serpentine square-wave micromixer is one of the simple and effective passive device for micromixing. In the present study, to further enhance the mixing efficiency of the device, horizontal straight portions of serpentine square wave mixer are replaced with convergent-divergent passages and the mixing performance of both mixers are evaluated in the Re range of 0 to 100. It is observed in the low Re (0 to 10), mixing in the square wave mixer with convergent-divergent portions (SQW-CD mixer) is governed completely by pure diffusion as in the case of square wave mixer with straight horizontal portions (SQW mixer). However, at high Re (Re > 10), the presence of convergent-divergent portions in the SQW-CD mixer considerably intensify the stretching and folding of samples in the mixing channel. Additionally, the extra recess available at the bends of SQW-CD mixer creates recirculation zones in the mixer. Therefore, a significant improvement in the mixing performance is achieved at high Re (Re > 10) for SQW-CD mixer as compared to conventional SQW mixer. This would allow shorter mixing lengths for SQW-CD mixer as compared to Sq wave mixer. However, with increase in Re, the rise in pressure drop is considerably high for SQW-CD mixer as compared to SQW mixer.
Collapse
Affiliation(s)
- Shasidhar Rampalli
- Mechanical Engineering Department, National Institute of Technology Warangal, Warangal, Telangana 506004, India
| | - T. Manoj Dundi
- Mechanical Engineering Department, National Institute of Technology Warangal, Warangal, Telangana 506004, India
| | - S. Chandrasekhar
- Mechanical Engineering Department, National Institute of Technology Warangal, Warangal, Telangana 506004, India
| | - V. R. K. Raju
- Mechanical Engineering Department, National Institute of Technology Warangal, Warangal, Telangana 506004, India
| | - V. P. Chandramohan
- Mechanical Engineering Department, National Institute of Technology Warangal, Warangal, Telangana 506004, India
| |
Collapse
|
21
|
Droplet-based optofluidic systems for measuring enzyme kinetics. Anal Bioanal Chem 2019; 412:3265-3283. [PMID: 31853606 DOI: 10.1007/s00216-019-02294-z] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 10/15/2019] [Accepted: 11/19/2019] [Indexed: 01/05/2023]
Abstract
The study of enzyme kinetics is of high significance in understanding metabolic networks in living cells and using enzymes in industrial applications. To gain insight into the catalytic mechanisms of enzymes, it is necessary to screen an enormous number of reaction conditions, a process that is typically laborious, time-consuming, and costly when using conventional measurement techniques. In recent times, droplet-based microfluidic systems have proved themselves to be of great utility in large-scale biological experimentation, since they consume a minimal sample, operate at high analytical throughput, are characterized by efficient mass and heat transfer, and offer high levels of integration and automation. The primary goal of this review is the introduction of novel microfluidic tools and detection methods for use in high-throughput and sensitive analysis of enzyme kinetics. The first part of this review focuses on introducing basic concepts of enzyme kinetics and describing most common microfluidic approaches, with a particular focus on segmented flow. Herein, the key advantages include accurate control over the flow behavior, efficient mass and heat transfer, multiplexing, and high-level integration with detection modalities. The second part describes the current state-of-the-art platforms for high-throughput and sensitive analysis of enzyme kinetics. In addition to our categorization of recent advances in measuring enzyme kinetics, we have endeavored to critically assess the limitations of each of these detection approaches and propose strategies to improve measurements in droplet-based microfluidics. Graphical abstract.
Collapse
|
22
|
Lee S, Lee W, Kim H, Bae PK, Park J, Kim J. Oscillatory flow-assisted efficient target enrichment with small volumes of sample by using a particle-based microarray device. Biosens Bioelectron 2019; 131:280-286. [PMID: 30849728 DOI: 10.1016/j.bios.2019.01.067] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2018] [Revised: 01/21/2019] [Accepted: 01/27/2019] [Indexed: 01/03/2023]
Abstract
In the study, we describe an oscillatory flow-assisted efficient target enrichment method by using a particle-based microarray device. Periodic oscillating flow effectively increased the mixing and binding performance between the target molecules in the sample solution and surface functionalized microparticles. Particles were trapped, secured, and released with an elastic microvalve structure operated via differences in the flow conditions. Single particle (20-µm diameter) trapping efficiency exceeded 95%. Secured particles can freely move inside each array element based on oscillating sample flow. Furthermore, the particles can be released from the array and collected at the outlet of the device, and this provides an opportunity for further off-chip analysis. As a proof-of-concept, we used the interaction between streptavidin-coated microparticles and fluorescence labeled biotin solution and demonstrated that target enrichment and detection based on oscillatory flow were significantly more efficient than that based on unidirectional or static flow. The applicability of the method was further examined by conducting an on-chip immunoassay to detect the presence of anti-Zika nonstructural protein 1 (NS1) monoclonal antibody. The limit of detection (LOD) was as low as 1 ng/mL with an assay time of only 10 min and less than 10 µL of sample consumption.
Collapse
Affiliation(s)
- Sanghyun Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Wonhyung Lee
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 37673, Republic of Korea
| | - Hojin Kim
- BioMEMS Lab., RadianQbio, 53 Gasan Digital 2-Ro, Geumcheon-Gu, Seoul 08588, Republic of Korea
| | - Pan Kee Bae
- BioNano Health Guard Research Center, 125 Gwahak-Ro, Yuseong-Gu, Daejeon 34141, Republic of Korea
| | - Jaechan Park
- Department of Neurosurgery, School of Medicine, Kyungpook National University, 680 Gukchaebosang-Ro, Jung-Gu, Daegu 41944, Republic of Korea
| | - Joonwon Kim
- Department of Mechanical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk 37673, Republic of Korea.
| |
Collapse
|
23
|
Bokare A, Takami A, Kim JH, Dong A, Chen A, Valerio R, Gunn S, Erogbogbo F. Herringbone-Patterned 3D-Printed Devices as Alternatives to Microfluidics for Reproducible Production of Lipid Polymer Hybrid Nanoparticles. ACS OMEGA 2019; 4:4650-4657. [PMID: 31459652 PMCID: PMC6648599 DOI: 10.1021/acsomega.9b00128] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Accepted: 02/18/2019] [Indexed: 05/09/2023]
Abstract
Major barriers to the implementation of nanotechnology include reproducible synthesis and scalability. Batch solution phase methods do not appear to have the potential to overcome these barriers. Microfluidic methods have been investigated as a means to enable controllable and reproducible synthesis; however, the most popular constituent of microfluidics, polydimethylsiloxane, is ill-suited for mass production. Multi-inlet vortex mixers (MIVMs) have been proposed as a method for scalable nanoparticle production; however, the control and reproducibility of the nanoparticle is wanting. Here, we investigate the ability to improve the control and reproducibility of nanoparticles produced by using 3D printed MIVMs with herringbone patterns in the flow channels. We compare three methods, viz., microfluidic, MIVM, and herringbone-patterned MIVM methods, for the synthesis of lipid-polymer hybrid nanoparticles (LPHNPs). The 3D printed herringbone-patterned MIVM method resulted in the smallest LPHNPs with the most uniform size distribution and shows more reproducible results as compared to the other two methods. To elucidate the mechanism underlying these results, concentration slices and vorticity streamlines of mixing chambers have been analyzed for 3D printed herringbone-patterned MIVM devices. The results bode well for LPHNPs, a formulation widely investigated for its improved therapeutic efficacy and biocompatibility. The herringbone-patterned device also has the potential to be broadly applied to many solution phase processes that take advantage of efficient mixing. The methods discussed here have broad implications for reproducible production of nanoparticles with constituents such as siRNA, proteins, quantum dots, and inorganic materials.
Collapse
Affiliation(s)
- Anuja Bokare
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| | - Ashley Takami
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| | - Jung Han Kim
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| | - Alexis Dong
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| | - Alan Chen
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| | - Ronald Valerio
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| | - Steven Gunn
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| | - Folarin Erogbogbo
- San Jose State University, 1 Washington Square, San
Jose, California 95112, United States
| |
Collapse
|
24
|
André E, Pannacci N, Dalmazzone C, Colin A. A new way to measure viscosity in droplet-based microfluidics for high throughput analysis. SOFT MATTER 2019; 15:504-514. [PMID: 30607416 DOI: 10.1039/c8sm02372g] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
In this work, we propose a new way to measure the viscosity of samples in a microfluidic device. By analysing the shape of droplets after an expansion, we can measure the viscosity of the phase inside the droplet knowing the surface tension between the two liquids, the flow rate, the geometry of the channel and the viscosity of the continuous phase. This work paves the way for future high throughput studies in the framework of digital microfluidics.
Collapse
Affiliation(s)
- Estelle André
- IFP Energies nouvelles, 1 et 4 avenue de Bois-Préau, 92852 Rueil-Malmaison, France
| | - Nicolas Pannacci
- IFP Energies nouvelles, 1 et 4 avenue de Bois-Préau, 92852 Rueil-Malmaison, France
| | - Christine Dalmazzone
- IFP Energies nouvelles, 1 et 4 avenue de Bois-Préau, 92852 Rueil-Malmaison, France
| | - Annie Colin
- Paris Sciences Lettres, ESPCI Paris, CBI-, MIE UMR 8321 10 rue Vauquelin, 75321 Paris cedex 06, France. and Université de Bordeaux, Centre de recherches Paul Pascal UPR 8641, 115 avenue Schweitzer, 33608 Pessac, France
| |
Collapse
|
25
|
Chiesa E, Dorati R, Pisani S, Conti B, Bergamini G, Modena T, Genta I. The Microfluidic Technique and the Manufacturing of Polysaccharide Nanoparticles. Pharmaceutics 2018; 10:pharmaceutics10040267. [PMID: 30544868 PMCID: PMC6321127 DOI: 10.3390/pharmaceutics10040267] [Citation(s) in RCA: 60] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Revised: 11/16/2018] [Accepted: 11/27/2018] [Indexed: 12/22/2022] Open
Abstract
The microfluidic technique has emerged as a promising tool to accelerate the clinical translation of nanoparticles, and its application affects several aspects, such as the production of nanoparticles and the in vitro characterization in the microenvironment, mimicking in vivo conditions. This review covers the general aspects of the microfluidic technique and its application in several fields, such as the synthesis, recovering, and samples analysis of nanoparticles, and in vitro characterization and their in vivo application. Among these, advantages in the production of polymeric nanoparticles in a well-controlled, reproducible, and high-throughput manner have been highlighted, and detailed descriptions of microfluidic devices broadly used for the synthesis of polysaccharide nanoparticles have been provided. These nanoparticulate systems have drawn attention as drug delivery vehicles over many years; nevertheless, their synthesis using the microfluidic technique is still largely unexplored. This review deals with the use of the microfluidic technique for the synthesis of polysaccharide nanoparticles; evaluating features of the most studied polysaccharide drug carriers, such as chitosan, hyaluronic acid, and alginate polymers. The critical assessment of the most recent research published in literature allows us to assume that microfluidics will play an important role in the discovery and clinical translation of nanoplatforms.
Collapse
Affiliation(s)
- Enrica Chiesa
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
| | - Rossella Dorati
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
| | - Silvia Pisani
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
| | - Bice Conti
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
| | - Gloria Bergamini
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
| | - Tiziana Modena
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
| | - Ida Genta
- Department of Drug Sciences, University of Pavia, Viale Taramelli 12, 27100 Pavia, Italy.
| |
Collapse
|
26
|
Hisey CL, Dorayappan KDP, Cohn DE, Selvendiran K, Hansford DJ. Microfluidic affinity separation chip for selective capture and release of label-free ovarian cancer exosomes. LAB ON A CHIP 2018; 18:3144-3153. [PMID: 30191215 DOI: 10.1039/c8lc00834e] [Citation(s) in RCA: 98] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Exosomes are nanoscale vesicles found in many bodily fluids which play a significant role in cell-to-cell signaling and contain biomolecules indicative of their cells of origin. Recently, microfluidic devices have provided the ability to efficiently capture exosomes based on specific membrane biomarkers, but releasing the captured exosomes intact and label-free for downstream characterization and experimentation remains a challenge. We present a herringbone-grooved microfluidic device which is covalently functionalized with antibodies against general and cancer exosome membrane biomarkers (CD9 and EpCAM) to isolate exosomes from small volumes of high-grade serous ovarian cancer (HGSOC) serum. Following capture, intact exosomes are released label-free using a low pH buffer and immediately neutralized downstream to ensure their stability. Characterization of captured and released exosomes was performed using fluorescence microscopy, nanoparticle tracking analysis, flow-cytometry, and SEM. Our results demonstrate the successful isolation of intact and label-free exosomes, indicate that the amount of both total and EpCAM+ exosomes increases with HGSOC disease progression, and demonstrate the downstream internalization of isolated exosomes by OVCAR8 cells. This device and approach can be utilized for a nearly limitless range of downstream exosome analytical and experimental techniques, both on and off-chip.
Collapse
Affiliation(s)
- Colin L Hisey
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
| | | | | | | | | |
Collapse
|
27
|
Abstract
The interdisciplinary research field of microfluidics has the potential to revolutionize current technologies that require the handling of a small amount of fluid, a fast response, low costs and automation. Microfluidic platforms that handle small amounts of liquid have been categorised as continuous-flow microfluidics and digital microfluidics. The first part of this paper discusses the recent advances of the two main and opposing applications of liquid handling in continuous-flow microfluidics: mixing and separation. Mixing and separation are essential steps in most lab-on-a-chip platforms, as sample preparation and detection are required for a variety of biological and chemical assays. The second part discusses the various digital microfluidic strategies, based on droplets and liquid marbles, for the manipulation of discrete microdroplets. More advanced digital microfluidic devices combining electrowetting with other techniques are also introduced. The applications of the emerging field of liquid-marble-based digital microfluidics are also highlighted. Finally, future perspectives on microfluidic liquid handling are discussed.
Collapse
|