1
|
Omweri JM, Saini S, Houson HA, Tekin V, Pyles JM, Parker CC, Lapi SE. Development of 52Mn Labeled Trastuzumab for Extended Time Point PET Imaging of HER2. Mol Imaging Biol 2024:10.1007/s11307-024-01948-4. [PMID: 39192059 DOI: 10.1007/s11307-024-01948-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 08/16/2024] [Accepted: 08/19/2024] [Indexed: 08/29/2024]
Abstract
PURPOSE Due to their long circulation time in the blood, monoclonal antibodies (mAbs) such as trastuzumab, are usually radiolabeled with long-lived positron emitters for the development of agents for Positron Emission Tomography (PET) imaging. Manganese-52 (52Mn, t1/2 = 5.6 d, β+ = 29.6%, E(βave) = 242 keV) is suitable for imaging at longer time points providing a complementary technique to Zirconium-89 (89Zr, t1/2 = 3.3 d, β+ = 22.7%, E(βave) = 396 keV)) because of its long half-life and low positron energy. To exploit these properties, we aimed to investigate suitable bifunctional chelators that could be readily conjugated to antibodies and labeled with 52Mn under mild conditions using trastuzumab as a proof-of-concept. PROCEDURES Trastuzumab was incubated with S-2-(4-isothiocyanatobenzyl)-1,4,7,10-tetraazacyclododecane tetraacetic acid (p-SCN-Bn-DOTA), 1-Oxa-4,7,10-tetraazacyclododecane-5-S-(4-isothiocyantobenzyl)-4,7,10-triacetic acid (p-SCN-Bn-Oxo-DO3A), and 3,6,9,15-tetraazabicyclo[9.3.1] pentadeca-1(15),11,13-triene-4-S-(4-isothiocyanatobenzyl)-3,6,9-triacetic acid (p-SCN-Bn-PCTA) at a tenfold molar excess. The immunoconjugates were purified, combined with [52Mn]MnCl2 at different ratios, and the labeling efficiency was assessed by iTLC. The immunoreactive fraction of the radiocomplex was determined through a Lindmo assay. Cell studies were conducted in HER2 + (BT474) and HER2- (MDA-MB-468) cell lines followed by in vivo studies. RESULTS Trastuzumab-Oxo-DO3A was labeled within 30 min at 37 °C with a radiochemical yield (RCY) of 90 ± 1.5% and with the highest specific activity of the chelators investigated of 16.64 MBq/nmol. The labeled compound was purified with a resulting radiochemical purity of > 98% and retained a 67 ± 1.2% immunoreactivity. DOTA and PCTA immunoconjugates resulted in < 50 ± 2.5% (RCY) with similar specific activity. Mouse serum stability studies of [52Mn]Mn-Oxo-DO3A-trastuzumab showed 95% intact complex for over 5 days. Cell uptake studies showed higher uptake in HER2 + (12.51 ± 0.83% /mg) cells compared to HER2- (0.85 ± 0.10%/mg) cells. PET images of mice bearing BT474 tumors showed high tumor uptake that was consistent with the biodistribution (42.02 ± 2.16%ID/g, 14 d) compared to MDA-MB-468 tumors (2.20 ± 0.80%ID/g, 14 d). Additionally, both models exhibited low bone uptake of < 1% ID/g. CONCLUSION The bifunctional chelator p-SCN-Bn-Oxo-DO3A is promising for the development of 52Mn radiopharmaceuticals as it was easily conjugated, radiolabeled at mild conditions, and illustrated stability for a prolonged duration both in vitro and in vivo. High-quality PET/CT images of [52Mn]Mn-Oxo-DO3A-trastuzumab were obtained 14 d post-injection. This study illustrates the potential of [52Mn]Mn-Oxo-DO3A for the evaluation of antibodies using PET imaging.
Collapse
Affiliation(s)
- James M Omweri
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL, 35205, USA
- Department of Radiology, University of Alabama at Birmingham, 1824 6th Ave S, WTI 310F, Birmingham, AL, 35294, USA
| | - Shefali Saini
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL, 35205, USA
- Department of Radiology, University of Alabama at Birmingham, 1824 6th Ave S, WTI 310F, Birmingham, AL, 35294, USA
| | - Hailey A Houson
- Department of Radiology, University of Alabama at Birmingham, 1824 6th Ave S, WTI 310F, Birmingham, AL, 35294, USA
| | - Volkan Tekin
- Department of Radiology, University of Alabama at Birmingham, 1824 6th Ave S, WTI 310F, Birmingham, AL, 35294, USA
| | - Jennifer M Pyles
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL, 35205, USA
- Department of Radiology, University of Alabama at Birmingham, 1824 6th Ave S, WTI 310F, Birmingham, AL, 35294, USA
| | - Candace C Parker
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL, 35205, USA
- Department of Radiology, University of Alabama at Birmingham, 1824 6th Ave S, WTI 310F, Birmingham, AL, 35294, USA
| | - Suzanne E Lapi
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL, 35205, USA.
- Department of Radiology, University of Alabama at Birmingham, 1824 6th Ave S, WTI 310F, Birmingham, AL, 35294, USA.
| |
Collapse
|
2
|
Taskozhina G, Batyrova G, Umarova G, Issanguzhina Z, Kereyeva N. The Manganese-Bone Connection: Investigating the Role of Manganese in Bone Health. J Clin Med 2024; 13:4679. [PMID: 39200820 PMCID: PMC11355939 DOI: 10.3390/jcm13164679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 07/17/2024] [Accepted: 08/06/2024] [Indexed: 09/02/2024] Open
Abstract
The complex relationship between trace elements and skeletal health has received increasing attention in the scientific community. Among these minerals, manganese (Mn) has emerged as a key element affecting bone metabolism and integrity. This review examines the multifaceted role of Mn in bone health, including its effects on bone regeneration, mineralization, and overall skeletal strength. This review article is based on a synthesis of experimental models, epidemiologic studies, and clinical trials of the mechanisms of the effect of Mn on bone metabolism. Current research data show that Mn is actively involved in the processes of bone remodeling by modulating the activity of osteoblasts and osteoclasts, as well as the main cells that regulate bone formation and resorption. Mn ions have a profound effect on bone mineralization and density by intricately regulating signaling pathways and enzymatic reactions in these cells. Additionally, Mn superoxide dismutase (MnSOD), located in bone mitochondria, plays a crucial role in osteoclast differentiation and function, protecting osteoclasts from oxidative damage. Understanding the nuances of Mn's interaction with bone is essential for optimizing bone strategies, potentially preventing and managing skeletal diseases. Key findings include the stimulation of osteoblast proliferation and differentiation, the inhibition of osteoclastogenesis, and the preservation of bone mass through the RANK/RANKL/OPG pathway. These results underscore the importance of Mn in maintaining bone health and highlight the need for further research into its therapeutic potential.
Collapse
Affiliation(s)
- Gulaim Taskozhina
- Department of Laboratory Diagnostics, West Kazakhstan Marat Ospanov Medical University, 68 Maresyev Street, Aktobe 030019, Kazakhstan
| | - Gulnara Batyrova
- Department of Laboratory Diagnostics, West Kazakhstan Marat Ospanov Medical University, 68 Maresyev Street, Aktobe 030019, Kazakhstan
| | - Gulmira Umarova
- Department of Evidence-Based Medicine and Scientific Management, West Kazakhstan Marat Ospanov Medical University, 68 Maresyev Street, Aktobe 030019, Kazakhstan;
| | - Zhamilya Issanguzhina
- Department of Children Disease No. 2, West Kazakhstan Marat Ospanov Medical University, 68 Maresyev Street, Aktobe 030019, Kazakhstan;
| | - Nurgul Kereyeva
- Department of Oncology, West Kazakhstan Marat Ospanov Medical University, 68 Maresyev Street, Aktobe 030019, Kazakhstan;
| |
Collapse
|
3
|
Harriswangler C, Omweri JM, Saini S, Valencia L, Esteban-Gómez D, Ranga M, Guidolin N, Baranyai Z, Lapi SE, Platas-Iglesias C. Improving the In Vivo Stability of [ 52Mn]Mn(II) Complexes with 18-Membered Macrocyclic Chelators for PET Imaging. J Med Chem 2024; 67:11242-11253. [PMID: 38935616 PMCID: PMC11247486 DOI: 10.1021/acs.jmedchem.4c00812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/29/2024]
Abstract
We report the [natMn/52Mn]Mn(II) complexes of the macrocyclic chelators PYAN [3,6,10,13-tetraaza-1,8(2,6)-dipyridinacyclotetradecaphane] and CHXPYAN [(41R,42R,101R,102R)-3,5,9,11-tetraaza-1,7(2,6)-dipyridina-4,10(1,2)-dicyclohexanacyclododecaphane]. The X-ray crystal structures of Mn-PYAN and Mn-CHXPYAN evidence distorted octahedral geometries through coordination of the nitrogen atoms of the macrocycles. Cyclic voltammetry studies evidence reversible processes due to the Mn(II)/Mn(III) pair, indicating that the complexes are resistant to oxidation. CHXPYAN forms a more thermodynamically stable and kinetically inert Mn(II) complex than PYAN. Radiochemical studies with the radioactive isotope manganese-52 (52Mn, t1/2 = 5.6 days) evidenced better radiochemical yields for CHXPYAN than for PYAN. Both [52Mn]Mn(II) complexes remained stable in mouse and human serum, so in vivo stability studies were carried out. Positron emission tomography/computed tomography scans and biodistribution assays indicated that [52Mn]Mn-PYAN has a distribution pattern similar to that of [52Mn]MnCl2, showing persistent radioactivity accumulation in the kidneys. Conversely, [52Mn]Mn-CHXPYAN remained stable in vivo, clearing quickly from the liver and kidneys.
Collapse
Affiliation(s)
- Charlene Harriswangler
- Universidade da Coruña, Centro Interdisciplinar de Química e Bioloxía (CICA) and Departamento de Química, Facultade de Ciencias, A Coruña 15071, Galicia, Spain
| | - James M Omweri
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35205, United States
- Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Shefali Saini
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35205, United States
- Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Laura Valencia
- Departamento de Química Inorgánica, Facultad de Ciencias, Universidade de Vigo, As Lagoas, Marcosende 36310, Pontevedra, Spain
| | - David Esteban-Gómez
- Universidade da Coruña, Centro Interdisciplinar de Química e Bioloxía (CICA) and Departamento de Química, Facultade de Ciencias, A Coruña 15071, Galicia, Spain
| | - Madalina Ranga
- Bracco Imaging SpA, CRB Trieste, AREA Science Park, ed. Q─S.S. 14 Km 163,5, 34149 Basovizza, TS, Italy
| | - Nicol Guidolin
- Bracco Imaging SpA, CRB Trieste, AREA Science Park, ed. Q─S.S. 14 Km 163,5, 34149 Basovizza, TS, Italy
| | - Zsolt Baranyai
- Bracco Imaging SpA, CRB Trieste, AREA Science Park, ed. Q─S.S. 14 Km 163,5, 34149 Basovizza, TS, Italy
| | - Suzanne E Lapi
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, Alabama 35205, United States
- Department of Radiology, University of Alabama at Birmingham, Birmingham, Alabama 35294, United States
| | - Carlos Platas-Iglesias
- Universidade da Coruña, Centro Interdisciplinar de Química e Bioloxía (CICA) and Departamento de Química, Facultade de Ciencias, A Coruña 15071, Galicia, Spain
| |
Collapse
|
4
|
Toàn NM, Vágner A, Nagy G, Ország G, Nagy T, Csikos C, Váradi B, Sajtos GZ, Kapus I, Szoboszlai Z, Szikra D, Trencsényi G, Tircsó G, Garai I. [ 52Mn]Mn-BPPA-Trastuzumab: A Promising HER2-Specific PET Radiotracer. J Med Chem 2024; 67:8261-8270. [PMID: 38690886 DOI: 10.1021/acs.jmedchem.4c00344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/03/2024]
Abstract
This study aimed to develop a novel radiotracer using trastuzumab and the long-lived [52Mn]Mn isotope for HER2-targeted therapy selection and monitoring. A new Mn(II) chelator, BPPA, synthesized from a rigid bispyclen platform possessing a picolinate pendant arm, formed a stable and inert Mn(II) complex with favorable relaxation properties. BPPA was converted into a bifunctional chelator (BFC), conjugated to trastuzumab, and labeled with [52Mn]Mn isotope. In comparison to DOTA-GA-trastuzumab, the BPPA-trastuzumab conjugate exhibits a labeling efficiency with [52Mn]Mn approximately 2 orders of magnitude higher. In female CB17 SCID mice bearing 4T1 (HER2-) and MDA-MB-HER2+ (HER2+) xenografts, [52Mn]Mn-BPPA-trastuzumab demonstrated superior uptake in HER2+ cells on day 3, with a 3-4 fold difference observed on day 7. Overall, the hexadentate BPPA chelator proves to be exceptional in binding Mn(II). Upon coupling with trastuzumab as a BFC ligand, it becomes an excellent imaging probe for HER2-positive tumors. [52Mn]Mn-BPPA-trastuzumab enables an extended imaging time window and earlier detection of HER2-positive tumors with superior tumor-to-background contrast.
Collapse
Affiliation(s)
- Ngô Minh Toàn
- Gyula Petrányi Doctoral School of Clinical Immunology and Allergology, Faculty of Medicine, University of Debrecen, Debrecen H-4032, Hungary
- Medical Imaging Clinic, Clinical Centre, University of Debrecen, Debrecen H-4032, Hungary
| | | | | | | | - Tamás Nagy
- Medical Imaging Clinic, Clinical Centre, University of Debrecen, Debrecen H-4032, Hungary
- Scanomed Ltd., Debrecen H-4032, Hungary
| | - Csaba Csikos
- Gyula Petrányi Doctoral School of Clinical Immunology and Allergology, Faculty of Medicine, University of Debrecen, Debrecen H-4032, Hungary
- Medical Imaging Clinic, Clinical Centre, University of Debrecen, Debrecen H-4032, Hungary
| | - Balázs Váradi
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Science and Technology, University of Debrecen, Debrecen H-4032, Hungary
- Doctoral School of Chemistry, Faculty of Science and Technology, University of Debrecen, Debrecen H-4032, Hungary
| | - Gergő Zoltán Sajtos
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Science and Technology, University of Debrecen, Debrecen H-4032, Hungary
- Doctoral School of Chemistry, Faculty of Science and Technology, University of Debrecen, Debrecen H-4032, Hungary
| | - István Kapus
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Science and Technology, University of Debrecen, Debrecen H-4032, Hungary
- Doctoral School of Chemistry, Faculty of Science and Technology, University of Debrecen, Debrecen H-4032, Hungary
| | | | - Dezső Szikra
- Medical Imaging Clinic, Clinical Centre, University of Debrecen, Debrecen H-4032, Hungary
- Scanomed Ltd., Debrecen H-4032, Hungary
| | - György Trencsényi
- Gyula Petrányi Doctoral School of Clinical Immunology and Allergology, Faculty of Medicine, University of Debrecen, Debrecen H-4032, Hungary
- Medical Imaging Clinic, Clinical Centre, University of Debrecen, Debrecen H-4032, Hungary
- Scanomed Ltd., Debrecen H-4032, Hungary
| | - Gyula Tircsó
- Department of Physical Chemistry, Institute of Chemistry, Faculty of Science and Technology, University of Debrecen, Debrecen H-4032, Hungary
| | - Ildikó Garai
- Gyula Petrányi Doctoral School of Clinical Immunology and Allergology, Faculty of Medicine, University of Debrecen, Debrecen H-4032, Hungary
- Medical Imaging Clinic, Clinical Centre, University of Debrecen, Debrecen H-4032, Hungary
- Scanomed Ltd., Debrecen H-4032, Hungary
| |
Collapse
|
5
|
Shanmugiah J, Zaheer J, Im C, Kang CM, Kim JS. Comparison of PET tracing and biodistribution between 64Cu-labeled micro-and nano-polystyrene in a murine inhalation model. Part Fibre Toxicol 2024; 21:2. [PMID: 38297341 PMCID: PMC10829228 DOI: 10.1186/s12989-023-00561-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 12/24/2023] [Indexed: 02/02/2024] Open
Abstract
INTRODUCTION Recent studies showed the presence of microplastic in human lungs. There remains an unmet need to identify the biodistribution of microplastic after inhalation. In this study, we traced the biodistribution of inhaled micro-sized polystyrene (mPS) and/or nano-sized PS (nPS) using 64Cu with PET in mice. METHODS We used 0.2-0.3-µm sized mPS and 20-nm sized nPS throughout. 64Cu-DOTA-mPS, 64Cu-DOTA-nPS and/or 64CuCl2 were used to trace the distribution in the murine inhalation model. PET images were acquired using an INVEON PET scanner at 1, 12, 24, 48, and 72 h after intratracheal instillation, and the SUVmax for interesting organs were determined, biodistribution was then determined in terms of percentage injected dose/gram of tissue (%ID/g). Ex vivo tissue-radio thin-layer chromatography (Ex vivo-radioTLC) was used to demonstrate the existence of 64Cu-DOTA-PS in tissue. RESULTS PET image demonstrated that the amount of 64Cu-DOTA-mPS retained within the lung was significantly higher than 64Cu-DOTA-nPS until 72 h; SUVmax values of 64Cu-DOTA-mPS in lungs was 11.7 ± 5.0, 48.3 ± 6.2, 65.5 ± 2.3, 42.2 ± 13.1, and 13.2 ± 2.3 at 1, 12, 24, 48, and 72 h respectively whereas it was 31.2 ± 3.1, 17.3 ± 5.9, 10.0 ± 3.4, 8.1 ± 2.4 and 8.9 ± 3.6 for 64Cu-DOTA-nPS at the corresponding timepoints. The biodistribution data supported the PET data with a similar pattern of clearance of the radioactivity from the lung. nPS cleared rapidly post instillation in comparison to mPS within the lungs. Higher accumulation of %ID/g for nPS (roughly 2 times) were observed compared to mPS in spleen, liver, intestine, thymus, kidney, brain, salivary gland, ovary, and urinary bladder. Ex vivo-radioTLC was used to demonstrate that the detected gamma rays originated from 64Cu-DOTA-mPS or nPS. CONCLUSION PET image demonstrated the differences in accumulations of mPS and/or nPS between lungs and other interesting organs. The information provided may be used as the basis for future studies on the toxicity of mPS and/or nPS.
Collapse
Affiliation(s)
- Joycie Shanmugiah
- Division of RI Application, Korea Institute of Radiological and Medical Sciences, 75 Nowon-Gil, Gongneung-Dong, Nowon-Gu, Seoul, 01812, Korea
- Radiological and Medico-Oncological Sciences, Korea National University of Science and Technology, Seoul, 01812, Republic of Korea
| | - Javeria Zaheer
- Division of RI Application, Korea Institute of Radiological and Medical Sciences, 75 Nowon-Gil, Gongneung-Dong, Nowon-Gu, Seoul, 01812, Korea
| | - Changkeun Im
- Division of RI Application, Korea Institute of Radiological and Medical Sciences, 75 Nowon-Gil, Gongneung-Dong, Nowon-Gu, Seoul, 01812, Korea
- Radiological and Medico-Oncological Sciences, Korea National University of Science and Technology, Seoul, 01812, Republic of Korea
| | - Choong Mo Kang
- Division of RI Application, Korea Institute of Radiological and Medical Sciences, 75 Nowon-Gil, Gongneung-Dong, Nowon-Gu, Seoul, 01812, Korea
- Radiological and Medico-Oncological Sciences, Korea National University of Science and Technology, Seoul, 01812, Republic of Korea
| | - Jin Su Kim
- Division of RI Application, Korea Institute of Radiological and Medical Sciences, 75 Nowon-Gil, Gongneung-Dong, Nowon-Gu, Seoul, 01812, Korea.
- Radiological and Medico-Oncological Sciences, Korea National University of Science and Technology, Seoul, 01812, Republic of Korea.
| |
Collapse
|
6
|
Omweri JM, Tekin V, Saini S, Houson HA, Jayawardana SB, Decato DA, Wijeratne GB, Lapi SE. Chelation chemistry of manganese-52 for PET imaging applications. Nucl Med Biol 2024; 128-129:108874. [PMID: 38154167 DOI: 10.1016/j.nucmedbio.2023.108874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 12/18/2023] [Accepted: 12/19/2023] [Indexed: 12/30/2023]
Abstract
INTRODUCTION Due to its decay and chemical properties, interest in manganese-52 has increased for development of long-lived PET radiopharmaceuticals. Its long half-life of 5.6 days, low average positron energy (242 keV), and sufficient positron decay branching ratio make it suitable for radiolabeling macromolecules for investigating slow biological processes. This work aims to establish suitable chelators for manganese-52 that can be radiolabeled at mild conditions through the evaluation of commercially available chelators. METHODS Manganese-52 was produced through the nuclear reaction NatCr(p,n)52Mn by irradiation of natural chromium targets on a TR24 cyclotron followed by purification through ion exchange chromatography. The radiolabeling efficiencies of chelators: DOTA, DiAmsar, TETA, DO3A, NOTA, 4'-Formylbenzo-15-crown-5, Oxo-DO3A, and DFO, were assessed by investigating the impact of pH, buffer type, and temperature. In vitro stability of [52Mn]Mn(DO3A)-, [52Mn]Mn(Oxo-DO3A)-, and [52Mn]Mn(DOTA)2- were evaluated in mouse serum. The radiocomplexes were also evaluated in vivo in mice. Crystals of [Mn(Oxo-DO3A)]- were synthesized by reacting Oxo-DO3A with MnCl2 and characterized by single crystal X-ray diffraction. RESULTS Yields of 185 ± 19 MBq (5.0 ± 0.5 mCi) (n = 4) of manganese-52 were produced at the end of a 4 h, 15 μA, bombardment with 12.5 MeV protons. NOTA, DO3A, DOTA, and Oxo-DO3A chelators were readily radiolabeled with >96 % radiochemical purity at all conditions. Manganese radiocomplexes of Oxo-DO3A, DOTA, and DO3A remained stable in vitro up to 5 days and exhibited different biodistribution profiles compared to [52Mn]MnCl2. The solid-state structure of Mn-Oxo-DO3A complex was determined by single-crystal X-ray diffraction. CONCLUSIONS DO3A and Oxo-DO3A are suitable chelators for manganese-52 which are readily radiolabeled at mild conditions with high molar activity, and demonstrate both in vitro and in vivo stability.
Collapse
Affiliation(s)
- James M Omweri
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL 35205, USA; Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Volkan Tekin
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Shefali Saini
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL 35205, USA; Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Hailey A Houson
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35294, USA
| | - Samith B Jayawardana
- Department of Chemistry and Biochemistry, University of Alabama, Tuscaloosa, AL 35487, USA
| | - Daniel A Decato
- Department of Chemistry and Biochemistry, University of Montana, MT 59812, USA
| | - Gayan B Wijeratne
- Department of Chemistry and Biochemistry, University of Alabama, Tuscaloosa, AL 35487, USA
| | - Suzanne E Lapi
- Department of Chemistry, University of Alabama at Birmingham, Birmingham, AL 35205, USA; Department of Radiology, University of Alabama at Birmingham, Birmingham, AL 35294, USA.
| |
Collapse
|
7
|
Barbaro F, Canton L, Carante MP, Colombi A, De Nardo L, Fontana A, Meléndez-Alafort L. The innovative 52g Mn for positron emission tomography (PET) imaging: Production cross section modeling and dosimetric evaluation. Med Phys 2023; 50:1843-1854. [PMID: 36433924 DOI: 10.1002/mp.16130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2022] [Revised: 09/14/2022] [Accepted: 10/10/2022] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Manganese is a paramagnetic element suitable for magnetic resonance imaging (MRI) of neuronal function. However, high concentrations of Mn2 + can be neurotoxic. 52g Mn may be a valid alternative as positron emission tomography (PET) imaging agent, to obtain information similar to that delivered by MRI but using trace levels of Mn2 + , thus reducing its toxicity. Recently, the reaction n a t $^{nat}$ V(α,x)52g Mn has been proposed as a possible alternative to the standard n a t $^{nat}$ Cr(p,x)52g Mn one, but improvements in the modeling were needed to better compare the two production routes. PURPOSE This work focuses on the development of precise simulations and models to compare the 52g Mn production from both reactions in terms of amount of activity and radionuclidic purity (RNP), as well as in terms of dose increase (DI) due to the co-produced radioactive contaminants, versus pure 52g MnCl2 . METHODS The nuclear code Talys has been employed to optimize the n a t $^{nat}$ V(α,x)52g Mn cross section by tuning the parameters of the microscopic level densities. Thick-target yields have been calculated from the expression of the rates as energy convolution of cross sections and stopping powers, and finally integrating the time evolution of the relevant decay chains. Dosimetric assessments of [ x x $^{xx}$ Mn]Cl2 have been accomplished with OLINDA software 2.2.0 using female and male adult phantoms and biodistribution data for 52g MnCl2 in normal mice. At the end, the yield of x x $^{xx}$ Mn radioisotopes estimated for the two production routes have been combined with the dosimetric results, to assess the DI at different times after the end of the irradiation. RESULTS Good agreement was obtained between cross-section calculations and measurements. The comparison of the two reaction channels suggests that n a t $^{nat}$ V(α,x)52g Mn leads to higher yield and higher purity, resulting in more favorable radiation dosimetry for patients. CONCLUSIONS Both n a t $^{nat}$ V(α,x) and n a t $^{nat}$ Cr(p,x) production routes provide clinically acceptable 52g MnCl2 for PET imaging. However, the n a t $^{nat}$ V(α,x)52g Mn reaction provides a DI systematically lower than the one obtainable with n a t $^{nat}$ Cr(p,x)52g Mn and a longer time window in which it can be used clinically (RNP ≥ 99%).
Collapse
Affiliation(s)
- Francesca Barbaro
- INFN, Sezione di Padova, Padova, Italy
- Dipartimento di Fisica dell'Università di Pavia, Pavia, Italy
| | | | - Mario Pietro Carante
- Dipartimento di Fisica dell'Università di Pavia, Pavia, Italy
- INFN, Sezione di Pavia, Pavia, Italy
| | - Alessandro Colombi
- Dipartimento di Fisica dell'Università di Pavia, Pavia, Italy
- INFN, Sezione di Pavia, Pavia, Italy
| | - Laura De Nardo
- INFN, Sezione di Padova, Padova, Italy
- Dipartimento di Fisica e Astronomia dell'Università di Padova, Padova, Italy
| | | | | |
Collapse
|
8
|
Firth G, Blower JE, Bartnicka JJ, Mishra A, Michaels AM, Rigby A, Darwesh A, Al-Salemee F, Blower PJ. Non-invasive radionuclide imaging of trace metal trafficking in health and disease: "PET metallomics". RSC Chem Biol 2022; 3:495-518. [PMID: 35656481 PMCID: PMC9092424 DOI: 10.1039/d2cb00033d] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Accepted: 04/07/2022] [Indexed: 12/05/2022] Open
Abstract
Several specific metallic elements must be present in the human body to maintain health and function. Maintaining the correct quantity (from trace to bulk) and location at the cell and tissue level is essential. The study of the biological role of metals has become known as metallomics. While quantities of metals in cells and tissues can be readily measured in biopsy and autopsy samples by destructive analytical techniques, their trafficking and its role in health and disease are poorly understood. Molecular imaging with radionuclides - positron emission tomography (PET) and single photon emission computed tomography (SPECT) - is emerging as a means to non-invasively study the acute trafficking of essential metals between organs, non-invasively and in real time, in health and disease. PET scanners are increasingly widely available in hospitals, and methods for producing radionuclides of some of the key essential metals are developing fast. This review summarises recent developments in radionuclide imaging technology that permit such investigations, describes the radiological and physicochemical properties of key radioisotopes of essential trace metals and useful analogues, and introduces current and potential future applications in preclinical and clinical investigations to study the biology of essential trace metals in health and disease.
Collapse
Affiliation(s)
- George Firth
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Julia E Blower
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Joanna J Bartnicka
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Aishwarya Mishra
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Aidan M Michaels
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Alex Rigby
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Afnan Darwesh
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Fahad Al-Salemee
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| | - Philip J Blower
- School of Biomedical Engineering & Imaging Sciences, King's College London, St. Thomas' Hospital London UK
| |
Collapse
|
9
|
Duatti A. Matched pairs of radioactive and paramagnetic isotopes. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00138-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
10
|
van der Meulen NP, Talip Z. Non-conventional radionuclides: The pursuit for perfection. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00052-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
11
|
Benešová M, Reischl G. Production of radionuclides: Cyclotrons and reactors. Nucl Med Mol Imaging 2022. [DOI: 10.1016/b978-0-12-822960-6.00003-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
12
|
Pyles JM, Massicano AV, Appiah JP, Bartels JL, Alford A, Lapi SE. Production of 52Mn using a semi-automated module. Appl Radiat Isot 2021; 174:109741. [DOI: 10.1016/j.apradiso.2021.109741] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Revised: 04/01/2021] [Accepted: 04/14/2021] [Indexed: 12/14/2022]
|
13
|
Chomet M, van Dongen GAMS, Vugts DJ. State of the Art in Radiolabeling of Antibodies with Common and Uncommon Radiometals for Preclinical and Clinical Immuno-PET. Bioconjug Chem 2021; 32:1315-1330. [PMID: 33974403 PMCID: PMC8299458 DOI: 10.1021/acs.bioconjchem.1c00136] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
![]()
Inert
and stable radiolabeling of monoclonal antibodies (mAb),
antibody fragments, or antibody mimetics with radiometals is a prerequisite
for immuno-PET. While radiolabeling is preferably fast, mild, efficient,
and reproducible, especially when applied for human use in a current
Good Manufacturing Practice compliant way, it is crucial that the
obtained radioimmunoconjugate is stable and shows preserved immunoreactivity
and in vivo behavior. Radiometals and chelators have
extensively been evaluated to come to the most ideal radiometal–chelator
pair for each type of antibody derivative. Although PET imaging of
antibodies is a relatively recent tool, applications with 89Zr, 64Cu, and 68Ga have greatly increased in
recent years, especially in the clinical setting, while other less
common radionuclides such as 52Mn, 86Y, 66Ga, and 44Sc, but also 18F as in [18F]AlF are emerging promising candidates for the radiolabeling
of antibodies. This review presents a state of the art overview of
the practical aspects of radiolabeling of antibodies, ranging from
fast kinetic affibodies and nanobodies to slow kinetic intact mAbs.
Herein, we focus on the most common approach which consists of first
modification of the antibody with a chelator, and after eventual storage
of the premodified molecule, radiolabeling as a second step. Other
approaches are possible but have been excluded from this review. The
review includes recent and representative examples from the literature
highlighting which radiometal–chelator–antibody combinations
are the most successful for in vivo application.
Collapse
Affiliation(s)
- Marion Chomet
- Amsterdam UMC, Vrije Universiteit Amsterdam, Radiology & Nuclear Medicine, Cancer Center Amsterdam, De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Guus A M S van Dongen
- Amsterdam UMC, Vrije Universiteit Amsterdam, Radiology & Nuclear Medicine, Cancer Center Amsterdam, De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| | - Danielle J Vugts
- Amsterdam UMC, Vrije Universiteit Amsterdam, Radiology & Nuclear Medicine, Cancer Center Amsterdam, De Boelelaan 1117, Amsterdam 1081 HV, The Netherlands
| |
Collapse
|
14
|
Zhou IY, Ramsay IA, Ay I, Pantazopoulos P, Rotile NJ, Wong A, Caravan P, Gale EM. Positron Emission Tomography-Magnetic Resonance Imaging Pharmacokinetics, In Vivo Biodistribution, and Whole-Body Elimination of Mn-PyC3A. Invest Radiol 2021; 56:261-270. [PMID: 33136686 PMCID: PMC7933117 DOI: 10.1097/rli.0000000000000736] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Mn-PyC3A is an experimental manganese (Mn)-based extracellular fluid magnetic resonance imaging (MRI) contrast agent that is being evaluated as a direct replacement for clinical gadolinium (Gd)-based contrast agents. The goals of this study were to use simultaneous positron emission tomography (PET)-MRI to (1) compare the whole-body pharmacokinetics, biodistribution, and elimination of Mn-PyC3A with the liver-specific contrast agent mangafodipir (Mn-DPDP), (2) determine the pharmacokinetics and fractional excretion of Mn-PyC3A in a rat model of renal impairment, and (3) compare whole-body elimination of Mn-PyC3A to gadoterate (Gd-DOTA) in a rat model of renal impairment. METHODS Mn-PyC3A and Mn-DPDP were radiolabeled with the positron emitting isotope Mn-52 via Mn2+ exchange with 52MnCl2. Dynamic simultaneous PET-MRI was used to measure whole-body pharmacokinetics and biodistribution of Mn-52 immediately and out to 7 days after an intravenous 0.2 mmol/kg dose of [52Mn]Mn-PyC3A to normal or to 5/6 nephrectomy rats or a 0.01 mmol/kg dose of [52Mn]Mn-DPDP to normal rats. The fractional excretion and 1- and 7-day biodistribution in rats after the injection of 2.0 mmol/kg [52Mn]Mn-PyC3A (n = 11 per time point) or 2.0 mmol/kg Gd-DOTA (n = 8 per time point) were quantified by gamma counting or Gd elemental analysis, respectively. Comparisons of Mn-PyC3A pharmacokinetics and in vivo biodistribution in normal and 5/6 nephrectomy rats and comparisons of ex vivo Mn versus Gd biodistribution data in 5/6 nephrectomy were made with an unpaired t test. RESULTS Dynamic PET-MRI data demonstrate that both [52Mn]Mn-PyC3A and [52Mn]Mn-DPDP were eliminated by mixed renal and hepatobiliary elimination but that a greater fraction of [52Mn]Mn-PyC3A was eliminated by renal filtration. Whole-body PET images show that Mn-52 from [52Mn]Mn-PyC3A was efficiently eliminated from the body, whereas Mn-52 from [52Mn]Mn-DPDP was retained throughout the body. The blood elimination half-life of [52Mn]Mn-PyC3A in normal and 5/6 nephrectomy rats was 13 ± 3.5 minutes and 23 ± 12 minutes, respectively (P = 0.083). Area under the curve between 0 and 60 minutes postinjection (AUC0-60) in the bladder of normal and 5/6 nephrectomy rats was 2600 ± 1700 %ID/cc*min and 750 ± 180 %ID/cc*min, respectively (P = 0.024), whereas AUC0-60 in the liver of normal and 5/6 nephrectomy rats was 33 ± 13 %ID/cc*min and 71 ± 16 %ID/cc*min, respectively (P = 0.011), indicating increased hepatobiliary elimination in 5/6 nephrectomy rats. The %IDs of Mn from [52Mn]Mn-PyC3A and Gd from Gd-DOTA recovered from 5/6 nephrectomy rats 1 day after injection were 2.0 ± 1.1 and 1.3 ± 0.34, respectively (P = 0.10) and 7 days after injection were 0.14 ± 0.11 and 0.41 ± 0.24, respectively (P = 0.0041). CONCLUSIONS Mn-PyC3A has different pharmacokinetics and is more efficiently eliminated than Mn-DPDP in normal rats. Mn-PyC3A is efficiently eliminated from both normal and 5/6 nephrectomy rats, with increased fractional hepatobiliary excretion from 5/6 nephrectomy rats. Mn-PyC3A is more completely eliminated than Gd-DOTA from 5/6 nephrectomy rats after 7 days.
Collapse
Affiliation(s)
| | - Ian A Ramsay
- From the Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School
| | - Ilknur Ay
- From the Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School
| | - Pamela Pantazopoulos
- From the Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School
| | - Nicholas J Rotile
- From the Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School
| | - Alison Wong
- From the Athinoula A. Martinos Center for Biomedical Imaging, Harvard Medical School
| | | | | |
Collapse
|
15
|
Carter LM, Kesner AL, Pratt EC, Sanders VA, Massicano AVF, Cutler CS, Lapi SE, Lewis JS. The Impact of Positron Range on PET Resolution, Evaluated with Phantoms and PHITS Monte Carlo Simulations for Conventional and Non-conventional Radionuclides. Mol Imaging Biol 2021; 22:73-84. [PMID: 31001765 DOI: 10.1007/s11307-019-01337-2] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
PURPOSE The increasing interest and availability of non-standard positron-emitting radionuclides has heightened the relevance of radionuclide choice in the development and optimization of new positron emission tomography (PET) imaging procedures, both in preclinical research and clinical practice. Differences in achievable resolution arising from positron range can largely influence application suitability of each radionuclide, especially in small-ring preclinical PET where system blurring factors due to annihilation photon acollinearity and detector geometry are less significant. Some resolution degradation can be mitigated with appropriate range corrections implemented during image reconstruction, the quality of which is contingent on an accurate characterization of positron range. PROCEDURES To address this need, we have characterized the positron range of several standard and non-standard PET radionuclides (As-72, F-18, Ga-68, Mn-52, Y-86, and Zr-89) through imaging of small-animal quality control phantoms on a benchmark preclinical PET scanner. Further, the Particle and Heavy Ion Transport code System (PHITS v3.02) code was utilized for Monte Carlo modeling of positron range-dependent blurring effects. RESULTS Positron range kernels for each radionuclide were derived from simulation of point sources in ICRP reference tissues. PET resolution and quantitative accuracy afforded by various radionuclides in practicable imaging scenarios were characterized using a convolution-based method based on positron annihilation distributions obtained from PHITS. Our imaging and simulation results demonstrate the degradation of small animal PET resolution, and quantitative accuracy correlates with increasing positron energy; however, for a specific "benchmark" preclinical PET scanner and reconstruction workflow, these differences were observed to be minimal given radionuclides with average positron energies below ~ 400 keV. CONCLUSION Our measurements and simulations of the influence of positron range on PET resolution compare well with previous efforts documented in the literature and provide new data for several radionuclides in increasing clinical and preclinical use. The results will support current and future improvements in methods for positron range corrections in PET imaging.
Collapse
Affiliation(s)
- L M Carter
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Adam Leon Kesner
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
| | - E C Pratt
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
- Department of Pharmacology, Weill Cornell Medical College, New York, NY, USA
| | - V A Sanders
- Collider-Accelerator Department, Brookhaven National Laboratory, Upton, NY, USA
| | - A V F Massicano
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - C S Cutler
- Collider-Accelerator Department, Brookhaven National Laboratory, Upton, NY, USA
| | - S E Lapi
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Jason S Lewis
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
- Department of Pharmacology, Weill Cornell Medical College, New York, NY, USA.
- Molecular Pharmacology Program, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
- Department of Radiology, Weill Cornell Medical College, New York, NY, USA.
- Radiochemistry and Molecular Imaging Probes Core, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
| |
Collapse
|
16
|
O'Doherty J, Mangini CD, Hamby DM, Boozer D, Singh N, Hippeläinen E. Estimation of absorbed radiation doses to skin and S-values for organs at risk due to nasal administration of PET agents using Monte Carlo simulations. Med Phys 2021; 48:871-880. [PMID: 33330987 DOI: 10.1002/mp.14669] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 10/29/2020] [Accepted: 12/08/2020] [Indexed: 11/11/2022] Open
Abstract
PURPOSE The intranasal (IN) administration of radiopharmaceuticals is of interest in being a viable route for the delivery of radiopharmaceuticals that do not ordinarily cross the blood-brain barrier (BBB). However, to be viable in a patient population, good image quality as well as safety of the administration should be demonstrated. This work provides radiation dosimetry calculations and simulations related to the radiation safety of performing such experiments in a human cohort. METHODS We performed Monte Carlo (MC) simulations to estimate radiation dose to the skin inside a cylindrical model of the nasal cavity assuming a homogenous distribution layer of 11 C and 18 F and calculated a geometry conversion factor (FP-C ) which can be used to convert from a planar geometry to a cylindrical geometry using more widely available software tools. We compared radiation doses from our simulated cylindrical geometry with the planar dose estimates employing our geometry conversion factor from VARSKIN 6.1 software and also from an analytical equation. Furthermore, in order to estimate radiation dosimetry to surrounding organs of interest, we performed a voxelized MC simulation of a fixed radioactivity inside the nasal cavity and calculated S-values to organs such as the eyes, thyroid, and brain. RESULTS MC simulations of contamination scenarios using planar absorbed doses of 15.50 and 8.60 mGy/MBq for 18 F and 11 C, respectively, and 35.70 and 19.80 mGy/MBq per hour for cylindrical geometries, leading to determination of an FP-C of 2.3. Planar absorbed doses (also in units of mGy/MBq) determined by the analytical equation were 16.96 and 8.68 (18 F and 11 C) and using VARSKIN were 16.60 and 9.26 (18 F and 11 C), respectively. Application of FP-C to these results demonstrates values with a maximum difference of 9.41% from the cylindrical geometry MC calculation, demonstrating that when accounting for geometry, more simplistic techniques can be utilized to estimate IN dosimetry. Voxelized MC simulations of radiation dosimetry from a fixed source of 1 MBq of activity confined to the nasal cavity resulted in S-values to the thyroid, eyes, and brain of 1.72 x 10-6 , 1.93 x 10-5 , and 3.51 x 10-6 mGy/MBq·s, respectively, for 18 F and 1.80 × 10-6 , 1.95 × 10-5 , and 3.54 × 10-6 mGy/MBq·s for 11 C. CONCLUSION Dosimetry concerns about IN administrations of PET radiotracers should be considered before clinical use. Values presented in the simulations such as the S-values can be further used for assessment of absorbed doses in cases of IN administration, and can be used to develop and adapt specific study protocols. All three presented methods provided similar results when considering the use of a geometry conversion factor for planar to cylindrical geometry, demonstrating that standard tools rather than dedicate MC simulations may be used to perform dose calculations in nasal administrations.
Collapse
Affiliation(s)
- Jim O'Doherty
- Clinical Imaging Research Centre, Centre for Translational Medicine, National University of Singapore, Singapore
| | | | - David M Hamby
- Renaissance Code Development LLC, Oregon, USA.,Department of Nuclear Science and Engineering, Oregon State University, Corvallis, USA
| | - David Boozer
- Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, USA
| | - Nisha Singh
- Department of Psychiatry, University of Oxford, UK
| | - Eero Hippeläinen
- Department of Physics, University of Helsinki, Helsinki, Finland.,HUS Medical imaging Center, Clinical Physiology and Nuclear Medicine, University of Helsinki and Helsinki University Hospital, Finland
| |
Collapse
|
17
|
Coenen HH, Ermert J. Expanding PET-applications in life sciences with positron-emitters beyond fluorine-18. Nucl Med Biol 2021; 92:241-269. [PMID: 32900582 DOI: 10.1016/j.nucmedbio.2020.07.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Accepted: 07/09/2020] [Indexed: 12/20/2022]
Abstract
Positron-emission-tomography (PET) has become an indispensable diagnostic tool in modern nuclear medicine. Its outstanding molecular imaging features allow repetitive studies on one individual and with high sensitivity, though no interference. Rather few positron-emitters with near favourable physical properties, i.e. carbon-11 and fluorine-18, furnished most studies in the beginning, preferably if covalently bound as isotopic label of small molecules. With the advancement of PET-devices the scope of in vivo research in life sciences and especially that of medical applications expanded, and other than "standard" PET-nuclides received increasing significance, like the radiometals copper-64 and gallium-68. Especially during the last decades, positron-emitters of other chemical elements have gotten into the focus of interest, concomitant with the technical advancements in imaging and radionuclide production. With known nuclear imaging properties and main production methods of emerging positron-emitters their usefulness for medical application is promising and even proven for several ones already. Unfortunate decay properties could be corrected for, and β+-emitters, especially with a longer half-life, provided new possibilities for application where slower processes are of importance. Further on, (bio)chemical features of positron-emitters of other elements, among there many metals, not only expanded the field of classical clinical investigations, but also opened up new fields of application. Appropriately labelled peptides, proteins and nanoparticles lend itself as newer probes for PET-imaging, e.g. in theragnostic or PET/MR hybrid imaging. Furthermore, the potential of non-destructive in-vivo imaging with positron-emission-tomography directs the view on further areas of life sciences. Thus, exploiting the excellent methodology for basic research on molecular biochemical functions and processes is increasingly encouraged as well in areas outside of health, such as plant and environmental sciences.
Collapse
Affiliation(s)
- Heinz H Coenen
- Institut für Neurowissenschaften und Medizin, INM-5, Nuklearchemie, Forschungszentrum Jülich GmbH, D-52425 Jülich, Germany.
| | - Johannes Ermert
- Institut für Neurowissenschaften und Medizin, INM-5, Nuklearchemie, Forschungszentrum Jülich GmbH, D-52425 Jülich, Germany.
| |
Collapse
|
18
|
Jansen FP, Deller TW, Fries MD, Khalighi MM, White SL, Radford LL, McConathy JE, Lapi SE. Real-Time Gain Control of PET Detectors and Evaluation With Challenging Radionuclides. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:71-80. [PMID: 32894710 DOI: 10.1109/tmi.2020.3022321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Accurate gain control of PET detectors is a prerequisite for quantitative accuracy. A shift in the 511 keV peak position can lead to errors in scatter correction, degrading quantitation. The PET detectors in a PET/MR scanner are subject to thermal transients due to eddy currents induced during gradient-intensive MRI sequences. Since the gain of silicon photomultiplier-based detectors changes with temperature, good gain control is particularly challenging. In this paper we describe a method that utilizes information from the entire singles spectrum to create a real-time gain control method that maintains gain of PET detectors stable within approximately ±0.5% (±2.5 keV) with varying levels of scatter and in the presence of significant thermal transients. We describe the methods used to combine information about multiple peaks and how this algorithm is implemented in a way that permits real-time processing on a field-programmable gate array. Simulations demonstrate rapid response time and stability. A method ("virtual scatter filter") is also described that extracts unscattered photopeak events from phantom data and demonstrates the accuracy of the photopeak for various radionuclides that emit energies in addition to the pure 511 keV annihilation peak. Radionuclides 52 Mn, 55 Co, 64 Cu, 89 Zr, 90 Y, and 124 I are included in the study for their various forms of spectral contamination.
Collapse
|
19
|
Lee JY, Mushtaq S, Park JE, Shin HS, Lee SY, Jeon J. Radioanalytical Techniques to Quantitatively Assess the Biological Uptake and In Vivo Behavior of Hazardous Substances. Molecules 2020; 25:molecules25173985. [PMID: 32882977 PMCID: PMC7504758 DOI: 10.3390/molecules25173985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/24/2020] [Accepted: 08/27/2020] [Indexed: 12/25/2022] Open
Abstract
Concern about environmental exposure to hazardous substances has grown over the past several decades, because these substances have adverse effects on human health. Methods used to monitor the biological uptake of hazardous substances and their spatiotemporal behavior in vivo must be accurate and reliable. Recent advances in radiolabeling chemistry and radioanalytical methodologies have facilitated the quantitative analysis of toxic substances, and whole-body imaging can be achieved using nuclear imaging instruments. Herein, we review recent literature on the radioanalytical methods used to study the biological distribution, changes in the uptake and accumulation of hazardous substances, including industrial chemicals, nanomaterials, and microorganisms. We begin with an overview of the radioisotopes used to prepare radiotracers for in vivo experiments. We then summarize the results of molecular imaging studies involving radiolabeled toxins and their quantitative assessment. We conclude the review with perspectives on the use of radioanalytical methods for future environmental research.
Collapse
Affiliation(s)
- Jae Young Lee
- Department of Environmental and Safety Engineering, Ajou University, Suwon 16499, Korea;
| | - Sajid Mushtaq
- Department of Nuclear Engineering, Pakistan Institute of Engineering and Applied Sciences, Islamabad 45650, Pakistan;
| | - Jung Eun Park
- Department of Applied Chemistry, School of Applied Chemical Engineering, Kyungpook National University, Daegu 41566, Korea;
| | - Hee Soon Shin
- Division of Functional Food Research, Korea Food Research Institute, 245, Nongsaengmyeong-ro, Iseo-myeon, Wanju-gun, Jeollabuk-do 55365, Korea; (H.S.S.); (S.-Y.L.)
- Food Biotechnology Program, University of Science and Technology, Daejeon 34113, Korea
| | - So-Young Lee
- Division of Functional Food Research, Korea Food Research Institute, 245, Nongsaengmyeong-ro, Iseo-myeon, Wanju-gun, Jeollabuk-do 55365, Korea; (H.S.S.); (S.-Y.L.)
- Food Biotechnology Program, University of Science and Technology, Daejeon 34113, Korea
| | - Jongho Jeon
- Department of Applied Chemistry, School of Applied Chemical Engineering, Kyungpook National University, Daegu 41566, Korea;
- Correspondence: ; Tel.: +82-53-950-5584
| |
Collapse
|
20
|
Kersemans V, Wallington S, Allen PD, Gilchrist S, Kinchesh P, Browning R, Vallis KA, Schilling K, Holdship P, Stork LA, Smart S. Manganese-free chow, a refined non-invasive solution to reduce gastrointestinal signal for T 1-weighted magnetic resonance imaging of the mouse abdomen. Lab Anim 2020; 54:353-364. [PMID: 31526094 PMCID: PMC7425378 DOI: 10.1177/0023677219869363] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 07/22/2019] [Indexed: 12/15/2022]
Abstract
Commercial mouse chow is designed to provide a complete, nutrient-rich diet, and it can contain upwards of 100 mg/kg manganese, an essential mineral. Manganese acts as a relaxation time-shortening contrast agent for both T1 and T2, and where standard chow is hydrated in the gastrointestinal tract, bright signals are produced when using T1-weighted imaging (T1WI). As a result of peristalsis, gastrointestinal hyperintensities result in temporally unstable signals, leading to image ghosting and decreased resolution from that prescribed. To avoid the problem, various methods of gastrointestinal tract modulation, including the use of intestinal cleansing with laxatives and dietary modulation, have been reported. Here, dietary modulation has been extended to the use of a biologically innocuous, long-term change of diet. In this study, we report on the use of a commercially available manganese-free chow to improve the image quality of the gastrointestinal tract. This manganese-free chow, apart from the omitted manganese which is available in tap water, is a complete diet and readily available. We investigated the time-dependent, diet-related gastrointestinal intensities on short-TR T1WI magnetic resonance imaging; monitored body mass, food and water consumption and standard blood biochemistry analysis following diet change; and determined manganese concentration in blood plasma following a five-day change to manganese-free chow. We show that the manganese-free chow presents a refinement to other gastrointestinal tract modulation, as it avoids the need for invasive procedures for gut voiding and can be provided ad libitum so that animals can be maintained with no need for prescribed diet change before imaging.
Collapse
Affiliation(s)
- Veerle Kersemans
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | - Sheena Wallington
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | - Philip D Allen
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | - Stuart Gilchrist
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | - Paul Kinchesh
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | - Richard Browning
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | - Katherine A Vallis
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | | | - Phil Holdship
- Department of Earth Sciences, University of Oxford, Oxford, UK
| | - Lee-Anne Stork
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| | - Sean Smart
- Cancer Research UK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Oxford, UK
| |
Collapse
|
21
|
Brandt M, Cardinale J, Rausch I, Mindt TL. Manganese in PET imaging: Opportunities and challenges. J Labelled Comp Radiopharm 2020; 62:541-551. [PMID: 31115089 PMCID: PMC6771670 DOI: 10.1002/jlcr.3754] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Revised: 05/09/2019] [Accepted: 05/11/2019] [Indexed: 12/22/2022]
Abstract
Several radionuclides of the transition metal manganese are known and accessible. Three of them, 51Mn, 52mMn, and 52gMn, are positron emitters that are potentially interesting for positron emission tomography (PET) applications and, thus, have caught the interest of the radiochemical/radiopharmaceutical and nuclear medicine communities. This mini‐review provides an overview of the production routes and physical properties of these radionuclides. For medical imaging, the focus is on the longer‐living 52gMn and its application for the radiolabelling of molecules and other entities exhibiting long biological half‐lives, the imaging of manganese‐dependent biological processes, and the development of bimodal PET/magnetic resonance imaging (MRI) probes in combination with paramagnetic natMn as a contrast agent.
Collapse
Affiliation(s)
- Marie Brandt
- Ludwig Boltzmann Institute Applied Diagnostics, General Hospital of Vienna, Vienna, Austria.,Department of Biomedical Imaging and Image Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria
| | - Jens Cardinale
- Ludwig Boltzmann Institute Applied Diagnostics, General Hospital of Vienna, Vienna, Austria.,Department of Biomedical Imaging and Image Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria
| | - Ivo Rausch
- Center for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria
| | - Thomas L Mindt
- Ludwig Boltzmann Institute Applied Diagnostics, General Hospital of Vienna, Vienna, Austria.,Department of Biomedical Imaging and Image Guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria.,Department of Inorganic Chemistry, Faculty of Chemistry, University of Vienna, Vienna, Austria
| |
Collapse
|
22
|
Sudarshana DM, Nair G, Dwyer JT, Dewey B, Steele SU, Suto DJ, Wu T, Berkowitz BA, Koretsky AP, Cortese ICM, Reich DS. Manganese-Enhanced MRI of the Brain in Healthy Volunteers. AJNR Am J Neuroradiol 2019; 40:1309-1316. [PMID: 31371354 DOI: 10.3174/ajnr.a6152] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Accepted: 06/13/2019] [Indexed: 12/22/2022]
Abstract
BACKGROUND AND PURPOSE The manganese ion is used as an intracellular MR imaging contrast agent to study neuronal function in animal models, but it remains unclear whether manganese-enhanced MR imaging can be similarly useful in humans. Using mangafodipir (Teslascan, a chelated manganese-based contrast agent that is FDA-approved), we evaluated the dynamics of manganese enhancement of the brain and glandular structures in the rostral head and neck in healthy volunteers. MATERIALS AND METHODS We administered mangafodipir intravenously at a rate of 1 mL/minute for a total dose of 5 μmol/kg body weight. Nine healthy adult volunteers (6 men/3 women; median age, 43 years) completed baseline history and physical examination, 3T MR imaging, and blood work. MR imaging also followed mangafodipir administration at various time points from immediate to 7 days, with delayed scans at 1-3 months. RESULTS The choroid plexus and anterior pituitary gland enhanced within 10 minutes of infusion, with enhancement persisting up to 7 and 30 days, respectively. Exocrine (parotid, submandibular, sublingual, and lacrimal) glands also enhanced avidly as early as 1 hour postadministration, generally resolving by 1 month; 3 volunteers had residual exocrine gland enhancement, which resolved by 2 months in 1 and by 3 months in the other 2. Mangafodipir did not affect clinical parameters, laboratory values, or T1-weighted signal in the basal ganglia. CONCLUSIONS Manganese ions released from mangafodipir successfully enable noninvasive visualization of intra- and extracranial structures that lie outside the blood-brain barrier without adverse clinical effects, setting the stage for future neuroradiologic investigation in disease.
Collapse
Affiliation(s)
- D M Sudarshana
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland.,Cleveland Clinic Lerner College of Medicine of Case Western Reserve University (D.M.S.), Cleveland, Ohio
| | - G Nair
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - J T Dwyer
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - B Dewey
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - S U Steele
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - D J Suto
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - T Wu
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - B A Berkowitz
- Department of Ophthalmology (B.A.B.), Visual and Anatomical Sciences, Wayne State University School of Medicine, Detroit, Michigan
| | - A P Koretsky
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - I C M Cortese
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| | - D S Reich
- From the National Institute of Neurological Disorders and Stroke (D.M.S., G.N., J.T.D., B.D., S.U.S., D.J.S., T.W., A.P.K., I.C.M.C., D.S.R.), National Institutes of Health, Bethesda, Maryland
| |
Collapse
|
23
|
Brandt MR, Vanasschen C, Ermert J, Coenen HH, Neumaier B. 52g/55Mn-Labelled CDTA-based trimeric complexes as novel bimodal PET/MR probes with high relaxivity. Dalton Trans 2019; 48:3003-3008. [DOI: 10.1039/c8dt04996c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Multimeric trans-1,2-diaminocyclohexane-N,N,N′,N′-tetraacetic acid (CDTA) derivatives labelled with a mixture of paramagnetic 55Mn(ii) and β+-emitting 52gMn(ii) offer the access to bimodal Positron Emission Tomography/Magnetic Resonance (PET/MR) tracers.
Collapse
Affiliation(s)
- Marie R. Brandt
- Institute of Neuroscience and Medicine
- INM-5: Nuclear Chemistry
- Jülich
- Germany
| | | | - Johannes Ermert
- Institute of Neuroscience and Medicine
- INM-5: Nuclear Chemistry
- Jülich
- Germany
| | - Heinz H. Coenen
- Institute of Neuroscience and Medicine
- INM-5: Nuclear Chemistry
- Jülich
- Germany
| | - Bernd Neumaier
- Institute of Neuroscience and Medicine
- INM-5: Nuclear Chemistry
- Jülich
- Germany
- Institute of Radiochemistry and Experimental Molecular Imaging
| |
Collapse
|
24
|
Chaple IF, Lapi SE. Production and Use of the First-Row Transition Metal PET Radionuclides 43,44Sc, 52Mn, and 45Ti. J Nucl Med 2018; 59:1655-1659. [DOI: 10.2967/jnumed.118.213264] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Accepted: 09/17/2018] [Indexed: 12/31/2022] Open
|
25
|
Gawne P, Man F, Fonslet J, Radia R, Bordoloi J, Cleveland M, Jimenez-Royo P, Gabizon A, Blower PJ, Long N, de Rosales RTM. Manganese-52: applications in cell radiolabelling and liposomal nanomedicine PET imaging using oxine (8-hydroxyquinoline) as an ionophore. Dalton Trans 2018; 47:9283-9293. [PMID: 29796500 PMCID: PMC6049564 DOI: 10.1039/c8dt00100f] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Accepted: 03/20/2018] [Indexed: 12/22/2022]
Abstract
The ionophore 8-hydroxyquinoline (oxine) has been used to radiolabel cells and liposomal medicines with 111In and, more recently, 89Zr, for medical nuclear imaging applications. Oxine has also shown promising ionophore activity for the positron-emitting radionuclide 52Mn that should allow imaging of labelled cells and nanomedicines for long periods of time (>14 days). However, to date, the radiometal complex formed and its full labelling capabilities have not been fully characterised. Here, we provide supporting evidence of the formation of [52Mn]Mn(oxinate)2 as the metastable complex responsible for its ionophore activity. The cell labelling properties of [52Mn]Mn(oxinate)2 were investigated with various cell lines. The liposomal nanomedicine, DOXIL® (Caelyx) was also labelled with [52Mn]Mn(oxinate)2 and imaged in vivo using PET imaging. [52Mn]Mn(oxinate)2 was able to label various cell lines with moderate efficiency (15-53%), however low cellular retention of 52Mn (21-25% after 24 h) was observed which was shown not to be due to cell death. PET imaging of [52Mn]Mn-DOXIL at 1 h and 24 h post-injection showed the expected pharmacokinetics and biodistribution of this stealth liposome, but at 72 h post-injection showed a profile matching that of free 52Mn, consistent with drug release. We conclude that oxine is an effective ionophore for 52Mn, but high cellular efflux of the isotope limits its use for prolonged cell tracking. [52Mn]Mn(oxinate)2 is effective for labelling and tracking DOXIL in vivo. The release of free radionuclide after liposome extravasation could provide a non-invasive method to monitor drug release in vivo.
Collapse
Affiliation(s)
- Peter Gawne
- School of Biomedical Engineering & Imaging Sciences
, King's College London
, St Thomas’ Hospital
,
London
, SE1 7EH
, UK
.
| | - Francis Man
- School of Biomedical Engineering & Imaging Sciences
, King's College London
, St Thomas’ Hospital
,
London
, SE1 7EH
, UK
.
| | - Jesper Fonslet
- The Hevesy Lab
, Technical University of Denmark
,
4000 Roskilde
, Denmark
| | - Riya Radia
- School of Biomedical Engineering & Imaging Sciences
, King's College London
, St Thomas’ Hospital
,
London
, SE1 7EH
, UK
.
| | - Jayanta Bordoloi
- School of Biomedical Engineering & Imaging Sciences
, King's College London
, St Thomas’ Hospital
,
London
, SE1 7EH
, UK
.
| | - Matthew Cleveland
- GSK Medicines Research Centre
,
Gunnels Wood Road
, Stevenage
, Hertfordshire
, SG1 2NY
, UK
| | - Pilar Jimenez-Royo
- GSK Medicines Research Centre
,
Gunnels Wood Road
, Stevenage
, Hertfordshire
, SG1 2NY
, UK
| | - Alberto Gabizon
- Oncology Institute
, Shaare Zedek Medical Center and Hebrew University-School of Medicine
,
Jerusalem 9103102
, Israel
| | - Philip J. Blower
- School of Biomedical Engineering & Imaging Sciences
, King's College London
, St Thomas’ Hospital
,
London
, SE1 7EH
, UK
.
| | - Nicholas Long
- Department of Chemistry
, Imperial College London
,
South Kensington Campus
, London SW7 2AZ
, UK
| | - Rafael T. M. de Rosales
- School of Biomedical Engineering & Imaging Sciences
, King's College London
, St Thomas’ Hospital
,
London
, SE1 7EH
, UK
.
| |
Collapse
|
26
|
Aluicio-Sarduy E, Ellison PA, Barnhart TE, Cai W, Nickles RJ, Engle JW. PET radiometals for antibody labeling. J Labelled Comp Radiopharm 2018; 61:636-651. [PMID: 29341227 PMCID: PMC6050152 DOI: 10.1002/jlcr.3607] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Revised: 12/29/2017] [Accepted: 01/05/2018] [Indexed: 02/06/2023]
Abstract
Recent advances in molecular characterization of tumors have made possible the emergence of new types of cancer therapies where traditional cytotoxic drugs and nonspecific chemotherapy can be complemented with targeted molecular therapies. One of the main revolutionary treatments is the use of monoclonal antibodies (mAbs) that selectively target the disseminated tumor cells while sparing normal tissues. mAbs and related therapeutics can be efficiently radiolabeled with a wide range of radionuclides to facilitate preclinical and clinical studies. Non-invasive molecular imaging techniques, such as Positron Emission Tomography (PET), using radiolabeled mAbs provide useful information on the whole-body distribution of the biomolecules, which may enable patient stratification, diagnosis, selection of targeted therapies, evaluation of treatment response, and prediction of dose limiting tissue and adverse effects. In addition, when mAbs are labeled with therapeutic radionuclides, the combination of immunological and radiobiological cytotoxicity may result in enhanced treatment efficacy. The pharmacokinetic profile of antibodies demands the use of long half-life isotopes for longitudinal scrutiny of mAb biodistribution and precludes the use of well-stablished short half-life isotopes. Herein, we review the most promising PET radiometals with chemical and physical characteristics that make the appealing for mAb labeling, highlighting those with theranostic radioisotopes.
Collapse
Affiliation(s)
| | - Paul A. Ellison
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, USA
| | - Todd E. Barnhart
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, USA
| | - Weibo Cai
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, USA
- University of Wisconsin-Madison, Department of Radiology, Madison, Wisconsin, USA
- University of Wisconsin-Madison Carbone Cancer Center, Carbon Cancer Center, Madison, Wisconsin, USA
| | - Robert Jerry Nickles
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, USA
| | - Jonathan W. Engle
- University of Wisconsin-Madison, Department of Medical Physics, Madison, Wisconsin, USA
- University of Wisconsin-Madison, Department of Radiology, Madison, Wisconsin, USA
| |
Collapse
|
27
|
Xie F, Peng F. Radiopharmaceuticals for Assessment of Altered Metabolism and Biometal Fluxes in Brain Aging and Alzheimer's Disease with Positron Emission Tomography. J Alzheimers Dis 2018; 59:527-536. [PMID: 28671127 DOI: 10.3233/jad-170280] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Aging is a risk factor for Alzheimer's disease (AD). There are changes of brain metabolism and biometal fluxes due to brain aging, which may play a role in pathogenesis of AD. Positron emission tomography (PET) is a versatile tool for tracking alteration of metabolism and biometal fluxes due to brain aging and AD. Age-dependent changes in cerebral glucose metabolism can be tracked with PET using 2-deoxy-2-[18F]-fluoro-D-glucose (18F-FDG), a radiolabeled glucose analogue, as a radiotracer. Based on different patterns of altered cerebral glucose metabolism, 18F-FDG PET was clinically used for differential diagnosis of AD and Frontotemporal dementia (FTD). There are continued efforts to develop additional radiopharmaceuticals or radiotracers for assessment of age-dependent changes of various metabolic pathways and biometal fluxes due to brain aging and AD with PET. Elucidation of age-dependent changes of brain metabolism and altered biometal fluxes is not only significant for a better mechanistic understanding of brain aging and the pathophysiology of AD, but also significant for identification of new targets for the prevention, early diagnosis, and treatment of AD.
Collapse
Affiliation(s)
- Fang Xie
- Department of Radiology, and Advanced ImagingResearch Center, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Fangyu Peng
- Department of Radiology, and Advanced ImagingResearch Center, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
28
|
Radka CD, Radford LL, Massicano AVF, DeLucas LJ, Lapi SE, Aller SG. Essential Metal Uptake in Gram-negative Bacteria: X-ray Fluorescence, Radioisotopes, and Cell Fractionation. J Vis Exp 2018. [PMID: 29443084 PMCID: PMC5912328 DOI: 10.3791/57169] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
We demonstrate a scalable method for the separation of the bacterial periplasm from the cytoplasm. This method is used to purify periplasmic protein for the purpose of biophysical characterization, and measure substrate transfer between periplasmic and cytoplasmic compartments. By carefully limiting the time that the periplasm is separated from the cytoplasm, the experimenter can extract the protein of interest and assay each compartment individually for substrate without carry-over contamination between compartments. The extracted protein from fractionation can then be further analyzed for three-dimensional structure determination or substrate-binding profiles. Alternatively, this method can be performed after incubation with a radiotracer to determine total percent uptake, as well as distribution of the tracer (and hence metal transport) across different bacterial compartments. Experimentation with a radiotracer can help differentiate between a physiological substrate and artefactual substrate, such as those caused by mismetallation. X-ray fluorescence can be used to discover the presence or absence of metal incorporation in a sample, as well as measure changes that may occur in metal incorporation as a product of growth conditions, purification conditions, and/or crystallization conditions. X-ray fluorescence also provides a relative measure of abundance for each metal, which can be used to determine the best metal energy absorption peak to use for anomalous X-ray scattering data collection. Radiometal uptake can be used as a method to validate the physiological nature of a substrate detected by X-ray fluorescence, as well as support the discovery of novel substrates.
Collapse
Affiliation(s)
- Christopher D Radka
- Graduate Biomedical Sciences Microbiology Theme, University of Alabama at Birmingham
| | | | | | | | - Suzanne E Lapi
- Department of Radiology, University of Alabama at Birmingham
| | - Stephen G Aller
- Department of Pharmacology and Toxicology, University of Alabama at Birmingham;
| |
Collapse
|
29
|
Graves SA, Ellison PA, Valdovinos HF, Barnhart TE, Nickles RJ, Engle JW. Half-life of 51Mn. ACTA ACUST UNITED AC 2017; 96. [PMID: 34327291 DOI: 10.1103/physrevc.96.014613] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The half-life of 51Mn was measured by serial gamma spectrometry of the 511-keV annihilation photon following decay by β + emission. Data were collected every 100 seconds for 100,000-230,000 seconds within each measurement (n = 4). The 511-keV incidence rate was calculated from the 511-keV spectral peak area and count duration, corrected for detector dead time and radioactive decay. Least-squares regression analysis was used to determine the half-life of 51Mn while accounting for the presence of background contaminants, notably 55Co. The result was 45.59 ± 0.07 min, which is the highest precision measurement to date and disagrees with the current Nuclear Data Sheets value by over 6σ.
Collapse
Affiliation(s)
- Stephen A Graves
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Paul A Ellison
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Hector F Valdovinos
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Todd E Barnhart
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Robert J Nickles
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| | - Jonathan W Engle
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705, USA
| |
Collapse
|