1
|
Müller-Graff FT, Spahn B, Herrmann DP, Kurz A, Voelker J, Hagen R, Rak K. [Comprehensive literature review on the application of the otological-surgical planning software OTOPLAN® for cochlear implantation. German version]. HNO 2024; 72:687-701. [PMID: 38587661 PMCID: PMC11422278 DOI: 10.1007/s00106-024-01461-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/28/2023] [Indexed: 04/09/2024]
Abstract
BACKGROUND The size of the human cochlear, measured by the diameter of the basal turn, varies between 7 and 11 mm. For hearing rehabilitation with cochlear implants (CI), the size of the cochlear influences the individual frequency map and the choice of electrode length. OTOPLAN® (CAScination AG [Bern, Switzerland] in cooperation with MED-EL [Innsbruck, Austria]) is a software tool with CE marking for clinical applications in CI treatment which allows for precise pre-planning based on cochlear size. This literature review aims to analyze all published data on the application of OTOPLAN®. MATERIALS AND METHODS The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied to identify relevant studies published in the PubMed search engine between January 2015 and February 2023 using the search terms "otoplan" [title/abstract] OR "anatomy-based fitting" [title/abstract] OR "otological software tool" [title/abstract] OR "computed tomography-based software AND cochlear" [title/abstract]. RESULTS The systematic review of the literature identified 32 studies on clinical use of OTOPLAN® in CI treatment. Most studies were reported from Germany (7 out of 32), followed by Italy (5), Saudi Arabia (4), the USA (4), and Belgium (3); 2 studies each were from Austria and China, and 1 study from France, India, Norway, South Korea, and Switzerland. In the majority of studies (22), OTOPLAN® was used to assess cochlear size, followed by visualizing the electrode position using postoperative images (5), three-dimensional segmentation of temporal bone structures (4), planning the electrode insertion trajectory (3), creating a patient-specific frequency map (3), planning of a safe drilling path through the facial recess (3), and measuring of temporal bone structures (1). CONCLUSION To date, OTOPLAN® is the only DICOM viewer with CE marking in the CI field that can process pre-, intra-, and postoperative images in the abovementioned applications.
Collapse
Affiliation(s)
- Franz-Tassilo Müller-Graff
- Klinik und Poliklinik für Hals‑, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen, Universitätsklinikum Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Deutschland.
| | - Björn Spahn
- Klinik und Poliklinik für Hals‑, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen, Universitätsklinikum Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Deutschland
| | - David P Herrmann
- Klinik und Poliklinik für Hals‑, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen, Universitätsklinikum Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Deutschland
| | - Anja Kurz
- Klinik und Poliklinik für Hals‑, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen, Universitätsklinikum Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Deutschland
| | - Johannes Voelker
- Klinik und Poliklinik für Hals‑, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen, Universitätsklinikum Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Deutschland
| | - Rudolf Hagen
- Klinik und Poliklinik für Hals‑, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen, Universitätsklinikum Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Deutschland
| | - Kristen Rak
- Klinik und Poliklinik für Hals‑, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen, Universitätsklinikum Würzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Deutschland
| |
Collapse
|
2
|
Abari J, Neudert M, Bornitz M, Van Gompel G, Provyn S, Al-Qubay M, Topsakal V. Noise exposure of the inner ear during robotic drilling. Eur Arch Otorhinolaryngol 2024:10.1007/s00405-024-08925-1. [PMID: 39198307 DOI: 10.1007/s00405-024-08925-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Accepted: 08/19/2024] [Indexed: 09/01/2024]
Abstract
INTRODUCTION Preserving the cochlear structures and thus hearing preservation, has become a prominent topic of discussion in cochlear implant (CI) surgery. Various approaches and soft surgical techniques have been described when approaching the inner ear. Robot-assisted cochlear implant surgery (RACIS) reaches the round window in a minimally invasive manner by following a trajectory of minimal trauma. This involves the drilling of a keyhole trajectory to the round window, through the facial recess, with no need for a complete mastoidectomy. It involves less drilling, less drilling time and less structural damage. A lot of attention has been paid to the structural traumatic causes of hearing loss but acoustic trauma during the exposure of the inner ear appears to be neglected topic. AIM The aim was to measure the noise exposure of the inner ear during the robotic drilling of the mastoid and bony overhang of the round window. The results were compared with the milling in conventional cochlear implantation surgery. INTERVENTION RACIS on fresh frozen human cadavers. OUTCOME MEASUREMENTS The equivalent frequency-weighted and time-averaged sound pressure level LAF in dB and the noise dose in % derived from a noise damage model, both obtained during RACIS. MATERIALS AND METHODS The robotic drilling of 6 trajectories towards the inner ear were performed, including 4 trajectories through round window access and 2 trajectories through cochleostomy. The results were compared with the data of 7 cases of conventional CI surgery that have been described in literature. The induced equivalent sound pressure level LAF was determined via an accelleration sensor at the zygomatic arch and a calibration according to bone conduction audiometry. A noise dose for the whole procedure was calculated from the equivalent sound pressure level LAF and the exposure time using a noise damage model. A noise dose of 100% is considered a critical exposure limit and values above are considered potentially harmful, with the risk of hearing impairment. RESULTS The maximum LAF was 82 dB during fiducial screw placement; 87 dB during middle ear access; 95 dB for the accesses through the round window and 88 dB for the accesses through cochleostomy. The noise dose due to the HEARO®-procedure was always far below the critical value of 100%. There was no acoustic trauma of the inner ear in all cases with the noise dose being smaller than 0.1% in five out of the six cases. The maximum LAF in the seven cases of conventional CI surgery was 118 dB with a maximum cumulative noise dose of 172.6%. The critical exposure limit of 100% was exceeded in three cases of conventional CI surgery. CONCLUSION RACIS provokes significantly less acoustic trauma than conventional mastoid surgery in our findings. There were no observable differences in noise exposure levels between a cochleostomy or a round window approach where the bony overhang needed to be drilled.
Collapse
Affiliation(s)
- Jaouad Abari
- Department of Otorhinolaryngology, Head and Neck Surgery, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium.
| | - Marcus Neudert
- Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, Head and Neck Surgery, Technische Universität Dresden, Dresden, Saxony, Germany
| | - Matthias Bornitz
- Faculty of Medicine Carl Gustav Carus, Department of Otorhinolaryngology, Head and Neck Surgery, Technische Universität Dresden, Dresden, Saxony, Germany
| | - Gert Van Gompel
- Department of Radiology, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Steven Provyn
- Anatomical Research and Clinical Studies, Vrije Universiteit Brussel, Brussels, Belgium
| | | | - Vedat Topsakal
- Vrije Universiteit Brussel, Brussels Health Campus, Brussels, Belgium
| |
Collapse
|
3
|
Wong K, Ruckenstein MJ. Triological Best Practice: Does Cochlear Implant Electrode Array Length Impact Performance? Laryngoscope 2024; 134:3421-3422. [PMID: 38661288 DOI: 10.1002/lary.31473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/22/2024] [Accepted: 04/12/2024] [Indexed: 04/26/2024]
Affiliation(s)
- Kevin Wong
- Department of Otorhinolaryngology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Michael J Ruckenstein
- Department of Otorhinolaryngology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
4
|
Rak K, Spahn B, Müller-Graff FT, Engert J, Voelker J, Hackenberg S, Hagen R, Petritsch B, Grunz JP, Bley T, Neun T, Huflage H. The Photon-Counting CT Enters the Field of Cochlear Implantation: Comparison to Angiography DynaCT and Conventional Multislice CT. Otol Neurotol 2024; 45:662-670. [PMID: 38865722 DOI: 10.1097/mao.0000000000004221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/14/2024]
Abstract
INTRODUCTION Cochlear duct length (CDL) measurement plays a role in the context of individualized cochlear implant (CI) surgery regarding an individualized selection and implantation of the CI electrode carrier and an efficient postoperative anatomy-based fitting process. The level of detail of the preoperative temporal bone CT scan depends on the imaging modality with major impact on CDL measurements and CI electrode contact position determination. The aim of this study was to evaluate the accuracy of perioperative CDL measurements and electrode contact determination in photon-counting CT (PCCT). METHODS Ten human fresh-frozen petrous bone specimens were examined with a first-generation PCCT. A clinically applicable radiation dose of 27.1 mGy was used. Scans were acquired before and after CI insertion. Postoperative measurement of the CDL was conducted using an otological planning software and 3D-curved multiplanar reconstruction. Investigation of electrode contact position was performed by two respective observers. Measurements were compared with a conventional multislice CT and to a high-resolution flat-panel volume CT with secondary reconstructions. RESULTS Pre- and postoperative CDL measurements in PCCT images showed no significant difference to high-resolution flat-panel volume CT. Postoperative CI electrode contact determination was also as precise as the flat-panel CT-based assessment. PCCT and flat-panel volume CT were equivalent concerning interobserver variability. CONCLUSION CDL measurement with PCCT was equivalent to flat-panel volume CT with secondary reconstructions. PCCT enabled highly precise postoperative CI electrode contact determination with substantial advantages over conventional multislice CT scanners.
Collapse
Affiliation(s)
- Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Bjoern Spahn
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Franz-Tassilo Müller-Graff
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Jonas Engert
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Johannes Voelker
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Stephan Hackenberg
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Rudolf Hagen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | | | | | - Thorsten Bley
- Department of Diagnostic and Interventional Radiology
| | - Tilmann Neun
- Institute for Diagnostic and Interventional Neuroradiology, University Hospital Wuerzburg, Wuerzburg, Germany
| | | |
Collapse
|
5
|
Müller-Graff FT, Spahn B, Herrmann DP, Kurz A, Völker J, Hagen R, Rak K. Comprehensive literature review on the application of the otological surgical planning software OTOPLAN® for cochlear implantation. HNO 2024:10.1007/s00106-023-01417-4. [PMID: 38861031 DOI: 10.1007/s00106-023-01417-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/28/2023] [Indexed: 06/12/2024]
Abstract
BACKGROUND The size of the human cochlear, measured by the diameter of the basal turn, varies between 7 and 11 mm. For hearing rehabilitation with cochlear implants (CI), the size of the cochlear influences the individual frequency map and the choice of electrode length. OTOPLAN® (CAScination AG [Bern, Switzerland] in cooperation with MED-EL [Innsbruck, Austria]) is a software tool with CE marking for clinical applications in CI treatment which allows for precise pre-planning based on cochlear size. This literature review aims to analyze all published data on the application of OTOPLAN®. MATERIALS AND METHODS The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were applied to identify relevant studies published in the PubMed search engine between January 2015 and February 2023 using the search terms "otoplan" [title/abstract] OR "anatomy-based fitting" [title/abstract] OR "otological software tool" [title/abstract] OR "computed tomography-based software AND cochlear" [title/abstract]. RESULTS The systematic review of the literature identified 32 studies on clinical use of OTOPLAN® in CI treatment. Most studies were reported from Germany (7 out of 32), followed by Italy (5), Saudi Arabia (4), the USA (4), and Belgium (3); 2 studies each were from Austria and China, and 1 study from France, India, Norway, South Korea, and Switzerland. In the majority of studies (22), OTOPLAN® was used to assess cochlear size, followed by visualizing the electrode position using postoperative images (5), three-dimensional segmentation of temporal bone structures (4), planning the electrode insertion trajectory (3), creating a patient-specific frequency map (3), planning of a safe drilling path through the facial recess (3), and measuring of temporal bone structures (1). CONCLUSION To date, OTOPLAN® is the only DICOM viewer with CE marking in the CI field that can process pre-, intra-, and postoperative images in the abovementioned applications.
Collapse
Affiliation(s)
- Franz-Tassilo Müller-Graff
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Wuerzburg, Germany.
| | - Björn Spahn
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Wuerzburg, Germany
| | - David P Herrmann
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Wuerzburg, Germany
| | - Anja Kurz
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Wuerzburg, Germany
| | - Johannes Völker
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Wuerzburg, Germany
| | - Rudolf Hagen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Wuerzburg, Germany
| | - Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Wuerzburg, Germany
| |
Collapse
|
6
|
Thompson NJ, Dillon MT, Nix EP, Overton AB, Selleck AM, Dedmon MM, Brown KD. Variables Affecting Cochlear Implant Performance After Loss of Residual Hearing. Laryngoscope 2024; 134:1868-1873. [PMID: 37767794 DOI: 10.1002/lary.31066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 08/15/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023]
Abstract
OBJECTIVE Determine variables that influence post-activation performance for cochlear implant (CI) recipients who lost low-frequency acoustic hearing. METHODS A retrospective review evaluated CNC word recognition for adults with normal to moderately severe low-frequency hearing (preoperative unaided thresholds of ≤70 dB HL at 250 Hz) who were implanted between 2012 and 2021 at a tertiary academic center, lost functional acoustic hearing, and were fit with a CI-alone device. Performance scores were queried from the 1, 3, 6, 12, and 24-month post-activation visits. A linear mixed model evaluated the effects of age at implantation, array length (long vs. mid/short), and preoperative low-frequency hearing (normal to mild, moderate, and moderately severe) on speech recognition with a CI alone. RESULTS 113 patients met the inclusion criteria. There was a significant main effect of interval (p < 0.001), indicating improved word recognition post-activation despite loss of residual hearing. There were significant main effects of age (p = 0.029) and array length (p = 0.038), with no effect of preoperative low-frequency hearing (p = 0.171). There was a significant 2-way interaction between age and array length (p = 0.018), indicating that older adults with mid/short arrays performed more poorly than younger adults with long lateral wall arrays when functional acoustic hearing was lost. CONCLUSION CI recipients with preoperative functional low-frequency hearing experience a significant improvement in speech recognition with a CI alone as compared to preoperative performance-despite the loss of low-frequency hearing. Age and electrode array length may play a role in post-activation performance. These data have implications for the preoperative counseling and device selection for hearing preservation candidates. LEVEL OF EVIDENCE 4 Laryngoscope, 134:1868-1873, 2024.
Collapse
Affiliation(s)
- Nicholas J Thompson
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Margaret T Dillon
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Evan P Nix
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Andrea B Overton
- Audiology Department, UNC Health, Chapel Hill, North Carolina, U.S.A
| | - A Morgan Selleck
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Matthew M Dedmon
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| | - Kevin D Brown
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, U.S.A
| |
Collapse
|
7
|
Angeli SI, Brown CS, Holcomb MA, Velandia SL, Eshraghi AA, Chiossone-Kerdel JA, Hoffer ME, Sanchez C, Telischi FF. Functional Hearing Preservation in Cochlear Implantation: The Miami Cocktail Effect. Otol Neurotol 2024; 45:376-385. [PMID: 38361325 DOI: 10.1097/mao.0000000000004134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
OBJECTIVE To investigate if pharmacological treatment with prednisone and L-N-acetylcysteine (STE + NAC) influence functional hearing preservation in cochlear implant (CI) surgery. STUDY DESIGNS Preimplantation and postimplantation longitudinal case-control study. SETTING Tertiary referral center. PATIENTS Pediatric and adult recipients of CI with preimplantation functional hearing defined as an average of air-conducted thresholds at 125, 250, and 500 Hz (low-frequency pure-tone average [LFPTA]) <80 dB. INTERVENTIONS Preimplantation and postimplantation audiometry. Weight-adjusted oral prednisone and L-N-acetylcysteine starting 2 days before surgery (Miami cocktail). Prednisone was continued for 3 days and L-N-acetylcysteine for 12 days after surgery, respectively. Cochlear implantation with conventional length electrodes. MAIN OUTCOME MEASURES Proportion of patients with LFPTA <80 dB, and LFPTA change at 1-year postimplantation. RESULTS All 61 patients received intratympanic and intravenous dexamethasone intraoperatively, with 41 patients receiving STE + NAC and 20 patients not receiving STE + NAC. At 1-year postimplantation, the proportion of functional hearing preservation was 83% in the STE + NAC group compared with 55% of subjects who did not receive STE + NAC ( p = 0.0302). The median LFPTA change for STE + NAC-treated and not treated subjects was 8.33 dB (mean, 13.82 ± 17.4 dB) and 18.34 dB (mean, 26.5 ± 23.4 dB), respectively ( p = 0.0401, Wilcoxon rank test). Perioperative STE + NAC treatment resulted in 10 dB of LFPTA better hearing than when not receiving this treatment. Better low-frequency preimplantation hearing thresholds were predictive of postimplantation functional hearing. No serious side effects were reported. CONCLUSION Perioperative STE + NAC, "The Miami Cocktail," was safe and superior to intraoperative steroids alone in functional hearing preservation 1-year after cochlear implantation.
Collapse
Affiliation(s)
| | | | - Meredith A Holcomb
- Department of Otolaryngology-Head and Neck Surgery, University of Miami Miller School of Medicine, Miami, Florida
| | - Sandra L Velandia
- Department of Otolaryngology-Head and Neck Surgery, University of Miami Miller School of Medicine, Miami, Florida
| | - Adrien A Eshraghi
- Department of Otolaryngology-Head and Neck Surgery, University of Miami Miller School of Medicine, Miami, Florida
| | | | | | - Chrisanda Sanchez
- Department of Otolaryngology-Head and Neck Surgery, University of Miami Miller School of Medicine, Miami, Florida
| | - Fred F Telischi
- Department of Otolaryngology-Head and Neck Surgery, University of Miami Miller School of Medicine, Miami, Florida
| |
Collapse
|
8
|
Spahn B, Ilgen L, Neun T, Müller-Graff FT, Schendzielorz P, Hagen R, Althoff D, Zabler S, Rak K. Dependence of Cochlear Duct Length Measurement on the Resolution of the Imaging Dataset. Otol Neurotol 2024; 45:e234-e240. [PMID: 38238926 DOI: 10.1097/mao.0000000000004088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
HYPOTHESIS Measurements of the cochlear duct length (CDL) are dependent on the resolution of the imaging dataset. BACKGROUND Previous research has shown highly precise cochlear measurements using 3D-curved multiplanar reconstruction (MPR) and flat-panel volume computed tomography (fpVCT). Thus far, however, there has been no systematic evaluation of the imaging dataset resolution required for optimal CDL measurement. Therefore, the aim of this study was to evaluate the dependence of CDL measurement on the resolution of the imaging dataset to establish a benchmark for future CDL measurements. METHODS fpVCT scans of 10 human petrous bone specimens were performed. CDL was measured using 3D-curved MPR with secondary reconstruction of the fpVCT scans (fpVCT SECO ) and increasing resolution from 466 to 99 μm. In addition, intraobserver variability was evaluated. A best-fit function for calculation of the CDL was developed to provide a valid tool when there are no measurements done with high-resolution imaging datasets. RESULTS Comparison of different imaging resolution settings showed significant differences for CDL measurement in most of the tested groups ( p < 0.05), except for the two groups with the highest resolution. Imaging datasets with a resolution lower than 200 μm showed lower intraobserver variability than the other resolution settings, although there were no clinically unacceptable errors with respect to the Bland-Altman plots. The developed best-fit function showed high accuracy for CDL calculation using resolution imaging datasets of 300 μm or lower. CONCLUSION 3D-curved MPR in fpVCT with a resolution of the imaging dataset of 200 μm or higher revealed the most precise CDL measurement. There was no benefit of using a resolution higher than 200 μm with regard to the accuracy of the CDL measurement.
Collapse
Affiliation(s)
- Bjoern Spahn
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Lukas Ilgen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Tilmann Neun
- Institute for Diagnostic and Interventional Neuroradiology, University of Wuerzburg
| | - Franz-Tassilo Müller-Graff
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Philipp Schendzielorz
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Rudolf Hagen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| | - Daniel Althoff
- Fraunhofer Development Center for X-ray Technology, Wuerzburg
| | - Simon Zabler
- Deggendorf Institute of Technology, Faculty of Applied Computer Science, Deggendorf, Germany
| | - Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center
| |
Collapse
|
9
|
Collins A, Foghsgaard S, Druce E, Margani V, Mejia O, O'Leary S. The Effect of Electrode Position on Behavioral and Electrophysiologic Measurements in Perimodiolar Cochlear Implants. Otol Neurotol 2024; 45:238-244. [PMID: 38238914 DOI: 10.1097/mao.0000000000004080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
BACKGROUND The shape and position of cochlear implant electrodes could potentially influence speech perception, as this determines the proximity of implant electrodes to the spiral ganglion. However, the literature to date reveals no consistent association between speech perception and either the proximity of electrode to the medial cochlear wall or the depth of insertion. These relationships were explored in a group of implant recipients receiving the same precurved electrode. METHODS This was a retrospective study of adults who underwent cochlear implantation with Cochlear Ltd.'s Slim Perimodiolar electrode at the Royal Victorian Eye and Ear Hospital between 2015 and 2018 (n = 52). Postoperative images were obtained using cone beam computed tomography (CBCT) and analyzed by multi-planar reconstruction to identify the position of the electrode contacts within the cochlea, including estimates of the proximity of the electrodes to the medial cochlear wall or modiolus and the angular depth of insertion. Consonant-vowel-consonant (CVC) monosyllabic phonemes were determined preoperatively, and at 3 and 12 months postoperatively. Electrically evoked compound action potential (ECAP) thresholds and impedance were measured from the implant array immediately after implantation. The relationships between electrode position and speech perception, electrode impedance, and ECAP threshold were an analyzed by Pearson correlation. RESULTS Age had a negative impact on speech perception at 3 months but not 12 months. None of the electrode-wide measures of proximity between electrode contacts and the modiolus, nor measures of proximity to the medial cochlear wall, nor the angular depth of insertion of the most apical electrode correlated with speech perception. However, there was a moderate correlation between speech perception and the position of the most basal electrode contacts; poorer speech perception was associated with a greater distance to the modiolus. ECAP thresholds were inversely related to the distance between electrode contacts and the modiolus, but there was no clear association between this distance and impedance. CONCLUSIONS Speech perception was significantly affected by the proximity of the most basal electrodes to the modiolus, suggesting that positioning of these electrodes may be important for optimizing speech perception. ECAP thresholds might provide an indication of this proximity, allowing for its optimization during surgery.
Collapse
Affiliation(s)
- Aaron Collins
- Department of Otolaryngology, The University of Melbourne, Melbourne, Australia
| | - Søren Foghsgaard
- Department of Otorhinolaryngology Head & Neck Surgery and Audiology, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark
| | - Edgar Druce
- Department of Otolaryngology, The University of Melbourne, Melbourne, Australia
| | - Valerio Margani
- Department of Neuroscience, Mental Health, and Sense Organs (NEMOS), Sant' Andrea University Hospital, Sapienza University, Rome, Italy
| | - Olivia Mejia
- sENTro Head and Neck Clinic, Manila, Philippines
| | | |
Collapse
|
10
|
Zagabathuni A, Padi KK, Kameswaran M, Subramani K. Development of Automated Tool for Electrode Array Insertion and its Study on Intracochlear Pressure. Laryngoscope 2024; 134:1388-1395. [PMID: 37584398 DOI: 10.1002/lary.30966] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 06/05/2023] [Accepted: 07/14/2023] [Indexed: 08/17/2023]
Abstract
Cochlear implantation is the most successful approach for people with profound sensorineural hearing loss. Manual insertion of the electrode array may result in damaging the soft tissue structures and basilar membrane. An automated electrode array insertion device is reported to be less traumatic in cochlear implant surgery. OBJECTIVES The present work develops a simple, reliable, and compact device for automatically inserting the electrode array during cochlear implantation and test the device to observe intracochlear pressure during simulated electrode insertion. METHODS The device actuates the electrode array by a roller mechanism. For testing the automated device, a straight cochlea having the dimension of the scala tympani and a model electrode is developed using a 3D printer. A pressure sensor is utilized to observe the pressure change at different insertional conditions. RESULTS The electrode is inserted into a prototype cochlea at different speeds without any pause, and it is noticed that the pressure is increased with the depth of insertion of the electrode irrespective of the speed of electrode insertion. The rate of pressure change is observed to be increased exponentially with the speed of insertion. CONCLUSION At an insertion speed of 0.15 mm/s, the peak pressure is observed to be 133 Pa, which can be further evaluated in anatomical models for clinical scenarios. LEVEL OF EVIDENCE N/A Laryngoscope, 134:1388-1395, 2024.
Collapse
Affiliation(s)
- Aparna Zagabathuni
- School of Materials Science and Engineering, National Institute of Technology Calicut, Calicut, India
| | - Kishore Kumar Padi
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, India
| | | | - Kanagaraj Subramani
- Department of Mechanical Engineering, Indian Institute of Technology Guwahati, Guwahati, India
| |
Collapse
|
11
|
Räth M, Schurzig D, Timm ME, Lenarz T, Warnecke A. Correlation of Scalar Cochlear Volume and Hearing Preservation in Cochlear Implant Recipients with Residual Hearing. Otol Neurotol 2024; 45:256-265. [PMID: 38361293 DOI: 10.1097/mao.0000000000004122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2024]
Abstract
OBJECTIVE Preservation of residual hearing is one of the main goals in cochlear implantation. There are many factors that can influence hearing preservation after cochlear implantation. The purpose of the present study was to develop an algorithm for validated preoperative cochlear volume analysis and to elucidate the role of cochlear volume in preservation of residual hearing preservation after atraumatic cochlear implantation. STUDY DESIGN Retrospective analysis. SETTING Tertiary referral center. PATIENTS A total of 166 cochlear implant recipients were analyzed. All patients were implanted with either a MED-EL (Innsbruck, Austria) FLEXSOFT (n = 3), FLEX28 (n = 72), FLEX26 (n = 1), FLEX24 (n = 41), FLEX20 (n = 38), or FLEX16 (n = 11, custom made device) electrode array through a round window approach. Main outcome measures: Cochlear volume as assessed after manual segmentation of cochlear cross-sections in cone beam computed tomography, and preservation of residual hearing 6 months after implantation were analyzed. The association between residual hearing preservation and cochlear volume was then assessed statistically. RESULTS Rapid and valid cochlear volume analysis was possible using the individual cross-sections and a newly developed and validated algorithm. Cochlear volume had the tendency to be larger in patients with hearing preservation than in those with hearing loss. Significant correlations with hearing preservation could be observed for the basal width and length of the basal turn. CONCLUSIONS Preservation of residual hearing after cochlear implantation may depend on cochlear volume but appears to be influenced more strongly by other cochlear dimensions.
Collapse
|
12
|
Kashani RG, Kocharyan A, Bennion DM, Scheperle RA, Etler C, Oleson J, Dunn CC, Claussen AD, Gantz BJ, Hansen MR. Combining Intraoperative Electrocochleography with Robotics-Assisted Electrode Array Insertion. Otol Neurotol 2024; 45:143-149. [PMID: 38206061 PMCID: PMC10786337 DOI: 10.1097/mao.0000000000004094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2024]
Abstract
OBJECTIVE To describe the use of robotics-assisted electrode array (EA) insertion combined with intraoperative electrocochleography (ECochG) in hearing preservation cochlear implant surgery. STUDY DESIGN Prospective, single-arm, open-label study. SETTING All procedures and data collection were performed at a single tertiary referral center. PATIENTS Twenty-one postlingually deaf adult subjects meeting Food and Drug Administration indication criteria for cochlear implantation with residual acoustic hearing defined as thresholds no worse than 65 dB at 125, 250, and 500 Hz. INTERVENTION All patients underwent standard-of-care unilateral cochlear implant surgery using a single-use robotics-assisted EA insertion device and concurrent intraoperative ECochG. MAIN OUTCOME MEASURES Postoperative pure-tone average over 125, 250, and 500 Hz measured at initial activation and subsequent intervals up to 1 year afterward. RESULTS Twenty-two EAs were implanted with a single-use robotics-assisted insertion device and simultaneous intraoperative ECochG. Fine control over robotic insertion kinetics could be applied in response to changes in ECochG signal. Patients had stable pure-tone averages after activation with normal impedance and neural telemetry responses. CONCLUSIONS Combining robotics-assisted EA insertion with intraoperative ECochG is a feasible technique when performing hearing preservation implant surgery. This combined approach may provide the surgeon a means to overcome the limitations of manual insertion and respond to cochlear feedback in real-time.
Collapse
Affiliation(s)
- Rustin G. Kashani
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Armine Kocharyan
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Douglas M. Bennion
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Rachel A. Scheperle
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Christine Etler
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Jacob Oleson
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Camille C. Dunn
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Alexander D. Claussen
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Bruce J. Gantz
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Marlan R. Hansen
- Department of Otolaryngology–Head and Neck Surgery, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| |
Collapse
|
13
|
Stritzel J, Ebrahimzadeh AH, Büchner A, Lanfermann H, Marschollek M, Wolff D. Landmark-based registration of a cochlear model to a human cochlea using conventional CT scans. Sci Rep 2024; 14:1115. [PMID: 38212412 PMCID: PMC10784596 DOI: 10.1038/s41598-023-50632-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Accepted: 12/22/2023] [Indexed: 01/13/2024] Open
Abstract
Cochlear implants can provide an advanced treatment option to restore hearing. In standard pre-implant procedures, many factors are already considered, but it seems that not all underlying factors have been identified yet. One reason is the low quality of the conventional computed tomography images taken before implantation, making it difficult to assess these parameters. A novel method is presented that uses the Pietsch Model, a well-established model of the human cochlea, as well as landmark-based registration to address these challenges. Different landmark numbers and placements are investigated by visually comparing the mean error per landmark and the registrations' results. The landmarks on the first cochlear turn and the apex are difficult to discern on a low-resolution CT scan. It was possible to achieve a mean error markedly smaller than the image resolution while achieving a good visual fit on a cochlear segment and directly in the conventional computed tomography image. The employed cochlear model adjusts image resolution problems, while the effort of setting landmarks is markedly less than the segmentation of the whole cochlea. As a next step, the specific parameters of the patient could be extracted from the adapted model, which enables a more personalized implantation with a presumably better outcome.
Collapse
Affiliation(s)
- Jenny Stritzel
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany.
| | - Amir Hossein Ebrahimzadeh
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany
| | - Andreas Büchner
- German Hearing Center, Hannover Medical School, Hannover, Germany
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - Heinrich Lanfermann
- Institute of Diagnostic and Interventional Neuroradiology, Hannover Medical School, Hannover, Germany
| | - Michael Marschollek
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany
| | - Dominik Wolff
- Peter L. Reichertz Institute for Medical Informatics of TU Braunschweig and Hannover Medical School, Hannover, Germany
| |
Collapse
|
14
|
Weiss NM, Breitsprecher T, Wozniak M, Bächinger D, Völter C, Mlynski R, Van de Heyning P, Van Rompaey V, Dazert S. Comparing linear and non-linear models to estimate the appropriate cochlear implant electrode array length-are current methods precise enough? Eur Arch Otorhinolaryngol 2024; 281:43-49. [PMID: 37466660 PMCID: PMC10764384 DOI: 10.1007/s00405-023-08064-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2023] [Accepted: 06/09/2023] [Indexed: 07/20/2023]
Abstract
PURPOSE In cochlear implantation with flexible lateral wall electrode arrays, a cochlear coverage (CC) range between 70% and 80% is considered ideal for optimal speech perception. To achieve this CC, the cochlear implant (CI) electrode array has to be chosen according to the individual cochlear duct length (CDL). Here, we mathematically analyzed the suitability of different flexible lateral wall electrode array lengths covering between 70% and 80% of the CDL. METHODS In a retrospective cross-sectional study preoperative high-resolution computed tomography (HRCT) from patients undergoing cochlear implantation was investigated. The CDL was estimated using an otosurgical planning software and the CI electrode array lengths covering 70-80% of the CDL was calculated using (i) linear and (ii) non-linear models. RESULTS The analysis of 120 HRCT data sets showed significantly different model-dependent CDL. Significant differences between the CC of 70% assessed from linear and non-linear models (mean difference: 2.5 mm, p < 0.001) and the CC of 80% assessed from linear and non-linear models (mean difference: 1.5 mm, p < 0.001) were found. In up to 25% of the patients none of the existing flexible lateral wall electrode arrays fit into this range. In 59 cases (49,2%) the models did not agree on the suitable electrode arrays. CONCLUSIONS The CC varies depending on the underlying CDL approximation, which critically influences electrode array choice. Based on the literature, we hypothesize that the non-linear method systematically overestimates the CC and may lead to rather too short electrode array choices. Future studies need to assess the accuracy of the individual mathematical models.
Collapse
Affiliation(s)
- Nora M Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany.
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.
- International Graduate School of Neuroscience (IGSN), Ruhr-University Bochum, Bochum, Germany.
| | - Tabita Breitsprecher
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
| | - Martin Wozniak
- MED-EL Elektromedizinische Geräte Deutschland GmbH, Starnberg, Deutschland
| | - David Bächinger
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
| | - Christiane Völter
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, "Otto Körner", University, Rostock, Germany
| | - Paul Van de Heyning
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- Department of Otorhinolaryngology and Head & Neck Surgery, Antwerp University Hospital, Antwerp, Belgium
| | - Vincent Van Rompaey
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- Department of Otorhinolaryngology and Head & Neck Surgery, Antwerp University Hospital, Antwerp, Belgium
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
| |
Collapse
|
15
|
Haumann S, Timm ME, Büchner A, Lenarz T, Salcher RB. Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea. Trends Hear 2024; 28:23312165241248973. [PMID: 38717441 PMCID: PMC11080744 DOI: 10.1177/23312165241248973] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 02/23/2024] [Accepted: 04/04/2024] [Indexed: 05/12/2024] Open
Abstract
To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
Collapse
Affiliation(s)
- Sabine Haumann
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Max E. Timm
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Andreas Büchner
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| | - Rolf B. Salcher
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- Cluster of Excellence “Hearing4All”, Hannover, Germany
| |
Collapse
|
16
|
Franke-Trieger A, Lailach S, Shetty J, Murrmann K, Zahnert T, Neudert M. Word Recognition with a Cochlear Implant in Relation to Prediction and Electrode Position. J Clin Med 2023; 13:183. [PMID: 38202190 PMCID: PMC10780042 DOI: 10.3390/jcm13010183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/11/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024] Open
Abstract
BACKGROUND the word recognition score (WRS) achieved with cochlear implants (CIs) varies widely. To account for this, a predictive model was developed based on patients' age and their pre-operative WRS. This retrospective study aimed to find out whether the insertion depth of the nucleus lateral-wall electrode arrays contributes to the deviation of the CI-achieved WRS from the predicted WRS. MATERIALS AND METHODS patients with a pre-operative maximum WRS > 0 or a pure-tone audiogram ≥80 dB were included. The insertion depth was determined via digital volume tomography. RESULTS fifty-three patients met the inclusion criteria. The median WRS achieved with the CI was 70%. The comparison of pre- and post-operative scores achieved with a hearing aid and a CI respectively in the aided condition showed a median improvement of 65 percentage points (pp). A total of 90% of the patients improved by at least 20 pp. The majority of patients reached or exceeded the prediction, with a median absolute error of 11 pp. No significant correlation was found between the deviation from the predicted WRS and the insertion depth. CONCLUSIONS our data support a previously published model for the prediction of the WRS after cochlear implantation. For the lateral-wall electrode arrays evaluated, the insertion depth did not influence the WRS with a CI.
Collapse
Affiliation(s)
- Annett Franke-Trieger
- Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307 Dresden, Germany (T.Z.)
| | | | | | | | | | | |
Collapse
|
17
|
Konrad S, Büchner A, Lenarz T, Paasche G. Impedance development after implantation of hybrid-L24 cochlear implant electrodes. Int J Audiol 2023; 62:1137-1144. [PMID: 36193989 DOI: 10.1080/14992027.2022.2125914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 09/13/2022] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Shorter and thinner electrodes were developed for preserving residual hearing after cochlear implantation by minimising trauma. As trauma is regarded as one of the causes of fibrous tissue formation after implantation, and increase in impedance is considered to be connected to fibrous tissue formation, the aim of the current study was to evaluate impedance development after implantation of Hybrid-L electrodes. DESIGN Impedance values were retrospectively collected from our clinical database and evaluated for all active contacts and basal, middle and apical contacts separately for up to 10 years. STUDY SAMPLES All 137 adult patients received a Hybrid-L electrode and had to be implanted for at least 1 year. RESULTS On average impedances increased to 13 kOhm before first fitting and dropped to 5-7 kOhm under electrical stimulation with lower values measured on apical contacts. Mean values remained stable over years, but variability increased. Values before first fitting were independent of age at implantation whereas lower values were found later in patients of higher age at implantation. CONCLUSION Despite smaller contacts, impedance values after start of electrical stimulation were comparable to published values of Contour electrodes. This might suggest less tissue growth with the Hybrid-L electrode array.
Collapse
Affiliation(s)
- Simon Konrad
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Andreas Büchner
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Hearing4all Cluster of Excellence, Hannover Medical School, Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Hearing4all Cluster of Excellence, Hannover Medical School, Hannover, Germany
| | - Gerrit Paasche
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
- Hearing4all Cluster of Excellence, Hannover Medical School, Hannover, Germany
| |
Collapse
|
18
|
Breitsprecher TM, Baumgartner WD, Brown K, Dazert S, Doyle U, Dhanasingh A, Großmann W, Hagen R, Van de Heyning P, Mlynski R, Neudert M, Rajan G, Rak K, Van Rompaey V, Schmutzhard J, Volkenstein S, Völter C, Wimmer W, Zernotti M, Weiss NM. Effect of Cochlear Implant Electrode Insertion Depth on Speech Perception Outcomes: A Systematic Review. OTOLOGY & NEUROTOLOGY OPEN 2023; 3:e045. [PMID: 38516541 PMCID: PMC10950166 DOI: 10.1097/ono.0000000000000045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Accepted: 10/29/2023] [Indexed: 03/23/2024]
Abstract
Objective The suitable electrode array choice is broadly discussed in cochlear implantation surgery. Whether to use a shorter electrode length under the aim of structure preservation versus choosing a longer array to achieve a greater cochlear coverage is a matter of debate. The aim of this review is to identify the impact of the insertion depth of a cochlear implant (CI) electrode array on CI users' speech perception outcomes. Databases Reviewed PubMed was searched for English-language articles that were published in a peer-reviewed journal from 1997 to 2022. Methods A systematic electronic search of the literature was carried out using PubMed to find relevant literature on the impact of insertion depth on speech perception. The review was conducted according to the preferred reporting items for systematic reviews and meta-analyses guidelines of reporting. Studies in both, children and adults with pre- or postlingual hearing loss, implanted with a CI were included in this study. Articles written in languages other than English, literature reviews, meta-analyses, animal studies, histopathological studies, or studies pertaining exclusively to imaging modalities without reporting correlations between insertion depth and speech outcomes were excluded. The risk of bias was determined using the "Risk of Bias in Nonrandomized Studies of Interventions" tool. Articles were extracted by 2 authors independently using predefined search terms. The titles and abstracts were screened manually to identify studies that potentially meet the inclusion criteria. The extracted information included: the study population, type of hearing loss, outcomes reported, devices used, speech perception outcomes, insertion depth (linear insertion depth and/or the angular insertion depth), and correlation between insertion depth and the speech perception outcomes. Results A total of 215 relevant studies were assessed for eligibility. Twenty-three studies met the inclusion criteria and were analyzed further. Seven studies found no significant correlation between insertion depth and speech perception outcomes. Fifteen found either a significant positive correlation or a positive effect between insertion depth and speech perception. Only 1 study found a significant negative correlation between insertion depth and speech perception outcomes. Conclusion Although most studies reported a positive effect of insertion depth on speech perception outcomes, one-third of the identified studies reported no correlation. Thus, the insertion depth must be considered as a contributing factor to speech perception rather than as a major decisive criterion. Registration This review has been registered in PROSPERO, the international prospective register of systematic reviews (CRD42021257547), available at https://www.crd.york.ac.uk/PROSPERO/.
Collapse
Affiliation(s)
- Tabita M. Breitsprecher
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
| | - Wolf-Dieter Baumgartner
- Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Medizinische Universität Wien, Wien, Austria
| | - Kevin Brown
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
| | - Una Doyle
- MED-EL Elektromedizinische Geraete Gesellschaft m.b.H., Innsbruck, Austria
| | - Anandhan Dhanasingh
- MED-EL Elektromedizinische Geraete Gesellschaft m.b.H., Innsbruck, Austria
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Wilma Großmann
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner,” Rostock University Medical Center, Rostock, Germany
| | - Rudolf Hagen
- Department of Otorhinolaryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, Comprehensive Hearing Center, University of Würzburg, Würzburg, Germany
| | - Paul Van de Heyning
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- Department of Otorhinolaryngology and Head & Neck Surgery, Antwerp University Hospital, Edegem, Belgium
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner,” Rostock University Medical Center, Rostock, Germany
| | - Marcus Neudert
- Department of Otorhinolaryngology Head and Neck Surgery, Technische Universität Dresden (oder TU Dresden), Faculty of Medicine (and University Hospital) Carl Gustav Carus, Dresden, Germany
| | - Gunesh Rajan
- Otolaryngology, Head and Neck Surgery, Medical School, University of Western Australia, Perth, Australia
- Faculty of Health Sciences and Medicine, University of Lucerne, Luzern, Switzerland
| | - Kristen Rak
- Department of Otorhinolaryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery, Comprehensive Hearing Center, University of Würzburg, Würzburg, Germany
| | - Vincent Van Rompaey
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- Department of Otorhinolaryngology and Head & Neck Surgery, Antwerp University Hospital, Edegem, Belgium
| | - Joachim Schmutzhard
- Department of Otorhinolaryngology-Head and Neck Surgery, Medical University Innsbruck, Innsbruck, Austria
| | - Stefan Volkenstein
- Department of Otorhinolaryngology, Head and Neck Surgery, Ruhr-University Bochum, Johannes Wesling Klinikum Minden, Bochum, Germany
| | - Christiane Völter
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
| | - Wilhelm Wimmer
- Department of Otolaryngology, Head and Neck Surgery, School of Medicine, Technical University of Munich (TUM), Munich, Germany
- Department of Otorhinolaryngology, TUM School of Medicine, Klinikum Rechts der Isar, Munich, Germany
| | - Mario Zernotti
- Division of Otolaryngology and Head and Neck Surgery, Sanatorio Allende, Catholic University of Córdoba and National University of Córdoba, Córdoba, Argentina
| | - Nora M. Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum, Germany
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- Department of Otorhinolaryngology and Head & Neck Surgery, Antwerp University Hospital, Edegem, Belgium
- Department of Otolaryngology, Head and Neck Surgery, School of Medicine, Technical University of Munich (TUM), Munich, Germany
- Department of Otorhinolaryngology, TUM School of Medicine, Klinikum Rechts der Isar, Munich, Germany
- International Graduate School of Neuroscience, Ruhr-University Bochum, Bochum, Germany
| |
Collapse
|
19
|
Nix EP, Thompson NJ, Brown KD, Dedmon MM, Selleck AM, Overton AB, Canfarotta MW, Dillon MT. Incidence of Cochlear Implant Electrode Contacts in the Functional Acoustic Hearing Region and the Influence on Speech Recognition with Electric-Acoustic Stimulation. Otol Neurotol 2023; 44:1004-1010. [PMID: 37758328 PMCID: PMC10840620 DOI: 10.1097/mao.0000000000004021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
OBJECTIVES To investigate the incidence of electrode contacts within the functional acoustic hearing region in cochlear implant (CI) recipients and to assess its influence on speech recognition for electric-acoustic stimulation (EAS) users. STUDY DESIGN Retrospective review. SETTING Tertiary referral center. PATIENTS One hundred five CI recipients with functional acoustic hearing preservation (≤80 dB HL at 250 Hz). INTERVENTIONS Cochlear implantation with a 24-, 28-, or 31.5-mm lateral wall electrode array. MAIN OUTCOME MEASURES Angular insertion depth (AID) of individual contacts was determined from imaging. Unaided acoustic thresholds and AID were used to calculate the proximity of contacts to the functional acoustic hearing region. The association between proximity values and speech recognition in quiet and noise for EAS users at 6 months postactivation was reviewed. RESULTS Sixty percent of cases had one or more contacts within the functional acoustic hearing region. Proximity was not significantly associated with speech recognition in quiet. Better performance in noise was observed for cases with close correspondence between the most apical contact and the upper edge of residual hearing, with poorer results for increasing proximity values in either the basal or apical direction ( r14 = 0.48, p = 0.043; r18 = -0.41, p = 0.045, respectively). CONCLUSION There was a high incidence of electrode contacts within the functional acoustic hearing region, which is not accounted for with default mapping procedures. The variability in outcomes across EAS users with default maps may be due in part to electric-on-acoustic interference, electric frequency-to-place mismatch, and/or failure to stimulate regions intermediate between the most apical electrode contact and the functional acoustic hearing region.
Collapse
Affiliation(s)
- Evan P Nix
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| | - Nicholas J Thompson
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| | - Kevin D Brown
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| | - Matthew M Dedmon
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| | - A Morgan Selleck
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| | | | - Michael W Canfarotta
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| | - Margaret T Dillon
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina School of Medicine, Chapel Hill, NC
| |
Collapse
|
20
|
Stebani J, Blaimer M, Zabler S, Neun T, Pelt DM, Rak K. Towards fully automated inner ear analysis with deep-learning-based joint segmentation and landmark detection framework. Sci Rep 2023; 13:19057. [PMID: 37925540 PMCID: PMC10625555 DOI: 10.1038/s41598-023-45466-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2022] [Accepted: 10/19/2023] [Indexed: 11/06/2023] Open
Abstract
Automated analysis of the inner ear anatomy in radiological data instead of time-consuming manual assessment is a worthwhile goal that could facilitate preoperative planning and clinical research. We propose a framework encompassing joint semantic segmentation of the inner ear and anatomical landmark detection of helicotrema, oval and round window. A fully automated pipeline with a single, dual-headed volumetric 3D U-Net was implemented, trained and evaluated using manually labeled in-house datasets from cadaveric specimen ([Formula: see text]) and clinical practice ([Formula: see text]). The model robustness was further evaluated on three independent open-source datasets ([Formula: see text] scans) consisting of cadaveric specimen scans. For the in-house datasets, Dice scores of [Formula: see text], intersection-over-union scores of [Formula: see text] and average Hausdorff distances of [Formula: see text] and [Formula: see text] voxel units were achieved. The landmark localization task was performed automatically with an average localization error of [Formula: see text] voxel units. A robust, albeit reduced performance could be attained for the catalogue of three open-source datasets. Results of the ablation studies with 43 mono-parametric variations of the basal architecture and training protocol provided task-optimal parameters for both categories. Ablation studies against single-task variants of the basal architecture showed a clear performance benefit of coupling landmark localization with segmentation and a dataset-dependent performance impact on segmentation ability.
Collapse
Affiliation(s)
- Jannik Stebani
- Magnetic Resonance and X-Ray Imaging Department, Fraunhofer Institute for Integrated Circuits IIS, 97074, Würzburg, Germany.
- Universität Würzburg, Experimentelle Physik V, 97074, Würzburg, Germany.
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, Universitätsklinikum Würzburg, 97080, Würzburg, Germany.
| | - Martin Blaimer
- Magnetic Resonance and X-Ray Imaging Department, Fraunhofer Institute for Integrated Circuits IIS, 97074, Würzburg, Germany
| | - Simon Zabler
- Magnetic Resonance and X-Ray Imaging Department, Fraunhofer Institute for Integrated Circuits IIS, 97074, Würzburg, Germany
- Faculty of Computer Science, Deggendorf Institute of Technology, Deggendorf, Germany
| | - Tilmann Neun
- Institute for Diagnostic and Interventional Neuroradiology, Universitätsklinikum Würzburg, 97080, Würzburg, Germany
| | - Daniël M Pelt
- Leiden Institute of Advanced Computer Science (LIACS), Universiteit Leiden, Leiden, CA, 2333, The Netherlands
| | - Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, Universitätsklinikum Würzburg, 97080, Würzburg, Germany
| |
Collapse
|
21
|
Aksoy DÖ, Meltem E, Karagöz Y, Yildirim G, Mahmutoğlu Ö, Mahmutoğlu AS. Comprehension of Cochlear Duct Length for Incomplete Partition Types. J Comput Assist Tomogr 2023; 47:982-988. [PMID: 37948375 DOI: 10.1097/rct.0000000000001488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
OBJECTIVE Preoperative assessment of the cochlear duct length (CDL) and cochlear dimensions allows the selection of optimized implants. We aimed to evaluate the CDL measurements in incomplete partition (IP) defect patients and to create a reference to the literature. METHODS Forty-one patients with IP (13 IP I, 23 IP II, and 5 IP III) and 30 controls were included in the study. The standardized cochlear image showing the basal turn in the most expansive plane was reconstructed from temporal high-resolution computed tomography images. Cochlear duct length measured manually (CDL-M) was measured by points placed consecutively on the lateral wall of the cochlea. The defined equations for estimating CDL (CDL measured according to Schurzig et al formula [CDL-Ɵ], CDL measured according to Escudé et al formula [CDL-E], CDL measured according to Alexiades et al formula [CDL-A]) were calculated from the same images. Cochlear duct length mean values obtained by each method were compared for each IP type. RESULTS The longest CDL value was found in the control group, irrespective of the calculation method. Incomplete partition II cases had the most extended mean CDL among IP types. Incomplete partition III had the shortest CDL among all groups' CDL-M values. However, the mean CDL-M values of IP types I and III showed close results. There was no significant difference between the CDL-E and CDL-M values of the control group. Similarly, no significant difference was found between CDL-Ɵ and CDL-M values in IP type III cases. However, the results of other estimating formulations of all groups differed significantly from CDL-M values. CONCLUSION Cochlear duct length differences were detected between the control group and IP subtypes. These differences should be considered when choosing the appropriate electrode length. Because the results of formulas estimating CDL may differ from CDL-M in both control and IP cases, it would be more appropriate to use manual measurements in clinical practice.
Collapse
Affiliation(s)
- Direnç Özlem Aksoy
- From the Department of Radiology, University of Health Sciences Istanbul Training and Research Hospital, Istanbul, Turkey
| | - Emine Meltem
- From the Department of Radiology, University of Health Sciences Istanbul Training and Research Hospital, Istanbul, Turkey
| | - Yeşim Karagöz
- From the Department of Radiology, University of Health Sciences Istanbul Training and Research Hospital, Istanbul, Turkey
| | - Gülşah Yildirim
- From the Department of Radiology, University of Health Sciences Istanbul Training and Research Hospital, Istanbul, Turkey
| | - Özdeş Mahmutoğlu
- Department of Radiology, University of Health Sciences Sisli Hamidiye Etfal Training and Research Hospital, Istanbul, Turkey
| | - Abdullah Soydan Mahmutoğlu
- From the Department of Radiology, University of Health Sciences Istanbul Training and Research Hospital, Istanbul, Turkey
| |
Collapse
|
22
|
Roßberg C, Timm M, Roßberg W, Kludt E, Bronzlik P, Lesinski-Schiedat A, Büchner A, Lenarz T. [Comparison of speech understanding taking into account the exact electrode position (SRA/MRA/CA)]. Laryngorhinootologie 2023; 102:850-855. [PMID: 37054746 DOI: 10.1055/a-2036-7896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/15/2023]
Abstract
Cochlear implantation has been a routine hearing rehabilitation procedure for years. Nevertheless, not all parameters that influence speech understanding after implantation are known. We test the hypothesis whether there is a connection between speech understanding and the position of different electrode types in relation to the modiolus in the cochlea with identical speech processors. For this purpose, in this retrospective study, we compare the hearing results with different electrode types ("Straight Research Array" [SRA], "Modiolar Research Array" [MRA] and "Contour Advance" [CA]) from the manufacturer Cochlear in matched pair groups.After creating three groups using "matched pairs" (n=52 patients per group), the cochlear parameters (length of the outer wall, angle of insertion, insertion depth, cochlear coverage and total length of the electrode in the cochlea, wrapping factor) were measured in the routinely performed manner pre- and post-operative high-resolution CT or DVT. The Freiburg monosyllabic understanding was used as a target variable one year after implantation.In the Freiburg monosyllabic test one year postoperatively, patients with MRA had a monosyllabic understanding of 51.2%, patients with SRA 49.5% and patients with CA 58.0%. It could be shown that with increasing cochlear coverage with MRA and CA, the speech understanding of the patients decreases and with SRA it increases. In addition, it could be shown that the monosyllabic understanding increases with increasing "wrapping factor".The results show that the position of the electrode to the modiolus is not the only factor explaining differences in outcome after cochlear implantation.
Collapse
Affiliation(s)
- Caroline Roßberg
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Medizinische Hochschule Hannover, Hannover, Germany
| | - Max Timm
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Medizinische Hochschule Hannover, Hannover, Germany
| | - Willi Roßberg
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Medizinische Hochschule Hannover, Hannover, Germany
| | - Eugen Kludt
- Deutsches Hörzentrum, Medizinische Hochschule Hannover, Hannover, Germany
| | - Paul Bronzlik
- Neuroradiologie, Medizinische Hochschule Hannover Klinikum, Hannover, Germany
| | - Anke Lesinski-Schiedat
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Medizinische Hochschule Hannover, Hannover, Germany
| | - Andreas Büchner
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Medizinische Hochschule Hannover, Hannover, Germany
| | - Thomas Lenarz
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Medizinische Hochschule Hannover, Hannover, Germany
| |
Collapse
|
23
|
Breitsprecher T, Mlynski R, Völter C, Van de Heyning P, Van Rompaey V, Dazert S, Weiss NM. Accuracy of Preoperative Cochlear Duct Length Estimation and Angular Insertion Depth Prediction. Otol Neurotol 2023; 44:e566-e571. [PMID: 37550888 DOI: 10.1097/mao.0000000000003956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/09/2023]
Abstract
OBJECTIVE In cochlear implantation with flexible lateral wall electrodes, a cochlear coverage of 70% to 80% is assumed to yield an optimal speech perception. Therefore, fitting the cochlear implant (CI) to the patient's individual anatomy has gained importance in recent years. For these reasons, the optimal angular insertion depth (AID) has to be calculated before cochlear implantation. One CI manufacturer offers a software that allows to visualize the AID of different electrode arrays. Here, it is hypothesized that these preoperative AID models overestimate the postoperatively measured insertion angle. This study aims to investigate the agreement between preoperatively estimated and postoperatively measured AID. STUDY DESIGN Retrospective cross-sectional study. SETTING Single-center tertiary referral center. PATIENTS Patients undergoing cochlear implantation. INTERVENTION Preoperative and postoperative high-resolution computed tomography (HRCT). MAIN OUTCOME MEASURES The cochlear duct length was estimated by determining cochlear parameters ( A value and B value), and the AID for the chosen electrode was (i) estimated by elliptic circular approximation by the software and (ii) measured manually postoperatively by detecting the electrode contacts after insertion. RESULTS A total of 80 HRCT imaging data sets from 69 patients were analyzed. The mean preoperative AID estimation was 662.0° (standard deviation [SD], 61.5°), and the mean postoperatively measured AID was 583.9° (SD, 73.6°). In all cases (100%), preoperative AID estimation significantly overestimated the postoperative determined insertion angle (mean difference, 38.1°). A correcting factor of 5% on preoperative AID estimation dissolves these differences. CONCLUSIONS The use of an electrode visualization tool may lead to shorter electrode array choices because of an overestimation of the insertion angle. Applying a correction factor of 0.95 on preoperative AID estimation is recommended.
Collapse
Affiliation(s)
- Tabita Breitsprecher
- Department of Otorhinolaryngology–Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum,
Germany
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner,” University Rostock, Germany
| | - Christiane Völter
- Department of Otorhinolaryngology–Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum,
Germany
| | - Paul Van de Heyning
- Department of Otorhinolaryngology and Head and Neck Surgery, Antwerp University Hospital, Belgium
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology and Head and Neck Surgery, Antwerp University Hospital, Belgium
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
| | - Stefan Dazert
- Department of Otorhinolaryngology–Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum,
Germany
| | - Nora M Weiss
- Department of Otorhinolaryngology–Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth-Hospital Bochum, Bochum,
Germany
- Department of Translational Neurosciences, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium
- International Graduate School of Neuroscience (IGSN), Ruhr-University Bochum, Bochum, Germany
| |
Collapse
|
24
|
Yoshimura H, Watanabe K, Nishio SY, Takumi Y, Usami SI. Determining optimal cochlear implant electrode array with OTOPLAN. Acta Otolaryngol 2023; 143:748-752. [PMID: 37737708 DOI: 10.1080/00016489.2023.2256790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Accepted: 08/25/2023] [Indexed: 09/23/2023]
Abstract
BACKGROUND To achieve better speech performance following cochlear implantation (CI), measuring the patient's cochlear duct length (CDL) and determining the appropriate length of the CI array are important. OBJECTIVE To investigate the CDL in CI patients after using the OTOPLAN software preoperatively and compare the results of angular insertion depth (AID) estimation by OTOPLAN and postoperative radiography. MATERIALS AND METHODS The study included 105 Japanese CI patients with normal cochleae. We measured the CDL using OTOPLAN and the position of the tip channel of the electrode for each selected electrode array, and estimated the AID using the software. RESULTS The mean CDL was 35.1 ± 1.6 mm. Preoperatively, the mean estimated AID was 580.3 ± 57.8°. Postoperative radiography revealed a mean AID of 583.0 ± 56.7°, demonstrating a strong linear correlation between the two measurements (R2 = 0.635). CONCLUSION AND SIGNIFICANCE Our findings revealed that CDL varies widely, which is consistent with previous studies. To achieve better speech perception, surgeons should select the appropriate length of CI electrode array based on the individual's CDL. Preoperative measurement of each CDL by OTOPLAN, which is clinically feasible and comparable to postoperative evaluation, can be used to ensure selection of the appropriate electrode array length.
Collapse
Affiliation(s)
- Hidekane Yoshimura
- Department of Otorhinolaryngology - Head and Neck Surgery, Shinshu University School of Medicine, Matsumoto, Japan
| | - Kizuki Watanabe
- Department of Otorhinolaryngology - Head and Neck Surgery, Shinshu University School of Medicine, Matsumoto, Japan
| | - Shin-Ya Nishio
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Matsumoto, Japan
| | - Yutaka Takumi
- Department of Otorhinolaryngology - Head and Neck Surgery, Shinshu University School of Medicine, Matsumoto, Japan
| | - Shin-Ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Matsumoto, Japan
| |
Collapse
|
25
|
Távora-Vieira D, Voola M, Kuthubutheen J, Friedland P, Gibson D, Acharya A. Evaluation of the Performance of OTOPLAN-Based Cochlear Implant Electrode Array Selection: A Retrospective Study. J Pers Med 2023; 13:1276. [PMID: 37623526 PMCID: PMC10455663 DOI: 10.3390/jpm13081276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 08/18/2023] [Accepted: 08/17/2023] [Indexed: 08/26/2023] Open
Abstract
Otoplan is a surgical planning software designed to assist with cochlear implant surgery. One of its outputs is a recommendation of electrode array type based on imaging parameters. In this retrospective study, we evaluated the differences in auditory outcomes between patients who were implanted with arrays corresponding to those recommended by the Otoplan software versus those in which the array selection differed from the Otoplan recommendation. Pre-operative CT images from 114 patients were imported into the software, and array recommendations were generated. These were compared to the arrays which had actually been implanted during surgery, both in terms of array type and length. As recommended, 47% of patients received the same array, 34% received a shorter array, and 18% received a longer array. For reasons relating to structure and hearing preservation, 83% received the more flexible arrays. Those who received stiffer arrays had cochlear malformations or ossification. A negative, although non-statistically significant correlation was observed between the CNC scores at 12 months and the absolute value of the difference between recommended array and implanted array. In conclusion, clinicians may be slightly biased toward shorter electrode arrays due to their perceived greater ability to achieve full insertion. Using 3D imaging during the pre-operative planning may improve clinicians' confidence to implant longer electrode arrays, where appropriate, to achieve optimum hearing outcomes.
Collapse
Affiliation(s)
- Dayse Távora-Vieira
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
- Faculty of Health Sciences, School of Allied Health, Curtin University, Perth, WA 6102, Australia
| | - Marcus Voola
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
| | - Jafri Kuthubutheen
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
- Sir Charles Gairdner Hospital, Perth, WA 6009, Australia
| | - Peter Friedland
- Medical School, Division of Surgery, The University of Western Australia, Perth, WA 6010, Australia
- Sir Charles Gairdner Hospital, Perth, WA 6009, Australia
| | - Daren Gibson
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
| | - Aanand Acharya
- Fiona Stanley Fremantle Hospitals Group, Perth, WA 6150, Australia
| |
Collapse
|
26
|
Weller T, Timm ME, Lenarz T, Büchner A. Cochlear coverage with lateral wall cochlear implant electrode arrays affects post-operative speech recognition. PLoS One 2023; 18:e0287450. [PMID: 37437046 DOI: 10.1371/journal.pone.0287450] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 06/06/2023] [Indexed: 07/14/2023] Open
Abstract
OBJECTIVES The goal was to investigate the relationship between the insertion angle/cochlear coverage of cochlear implant electrode arrays and post-operative speech recognition scores in a large cohort of patients implanted with lateral wall electrode arrays. METHODS Pre- and post-operative cone beam computed tomography scans of 154 ears implanted with lateral wall electrode arrays were evaluated. Traces of lateral wall and electrode arrays were combined into a virtual reconstruction of the implanted cochlea. This reconstruction was used to measure insertion angles and proportional cochlear coverage. Word recognition scores and sentence recognition scores measured 12 months after implantation using electric-only stimulation were used to examine the relationship between cochlear coverage/insertion angle and implantation outcomes. RESULTS Post-operative word recognition scores and the difference between post- and pre-operative word recognition scores were positively correlated with both cochlear coverage and insertion angle, however sentence recognition scores were not. A group-wise comparison of word recognition scores revealed that patients with cochlear coverage below 70% performed significantly worse than patients with coverage between 79%-82% (p = 0.003). Performance of patients with coverage above 82% was on average poorer than between 79%-82, although this finding was not statistically significant (p = 0.84). Dividing the cohort into groups based on insertion angle quadrants revealed that word recognition scores were highest above 450° insertion angle, sentence recognition scores were highest between 450° and 630° and the difference between pre- and post-operative word recognition scores was largest between 540° and 630°, however none of these differences reached statistical significance. CONCLUSIONS The results of this study show that cochlear coverage has an effect on post-operative word recognition abilities and the benefit patients receive from their implant. Generally, higher coverage led to better outcomes, however there were results indicating that insertion past 82% cochlear coverage may not provide an additional benefit for word recognition. These findings can be useful for choosing the optimal electrode array and thereby improving cochlear implantation outcomes on a patient-individual basis.
Collapse
Affiliation(s)
- Tobias Weller
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- German Hearing Center (DHZ), Hannover, Germany
- Cluster of Excellence "Hearing4All", Oldenburg, Germany
| | - Max Eike Timm
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- German Hearing Center (DHZ), Hannover, Germany
- Cluster of Excellence "Hearing4All", Oldenburg, Germany
| | - Andreas Büchner
- Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
- German Hearing Center (DHZ), Hannover, Germany
- Cluster of Excellence "Hearing4All", Oldenburg, Germany
| |
Collapse
|
27
|
Skarzynski PH, Lorens A, Gos E, Kolodziejak A, Obrycka A, Skarżyńska MB, Czajka N, Porowski M, Skarzynski H. Outcomes of Cochlear Implantation Using FLEX26 Electrode: Audiological Results and Quality of Life after 12 Months. Audiol Neurootol 2023; 28:458-465. [PMID: 37315543 DOI: 10.1159/000530883] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Accepted: 04/04/2023] [Indexed: 06/16/2023] Open
Abstract
INTRODUCTION The electrode length is one of the many factors impacted on results of cochlear implantation. Among lateral wall flexible electrode arrays the latest one is FLEX26 (MED-EL GmbH, Innsbruck, Austria). The main aim of the study was to evaluate the preservation of residual hearing, the level of speech understanding, and quality of life after cochlear implantation with FLEX26 electrode array. METHODS The study was conducted in a tertiary referral centre. Fifty-two patients implanted unilaterally with FLEX26, including 10 EAS patients (electric acoustic stimulation) and 42 ES patients (electric stimulation). The intervention was minimally invasive cochlear implantation via the round window. Pure-tone audiometry (0.125-8 kHz) was performed preoperatively and at 1, 6, and 12 months postoperatively. Twelve-month hearing preservation was established using HEARRING group formula. Quality of life was measured with AQoL-8D (Assessment of Quality of Life-8 Dimensions) pre- and postoperatively. RESULTS Residual hearing was preserved in 88.8% EAS patients. Quality of life was significantly better postoperatively in comparison to preoperative period (the effect size for overall quality of life was 0.49). Especially, it increased in relationships and senses dimensions (the effect sizes 0.47 and 0.44, respectively). CONCLUSION Preservation of residual hearing can be achieved in the majority of patients implanted with FLEX26. Improvement of quality of life was also documented. FLEX26 seems to be an option for surgeons who seek an electrode providing sufficient cochlear coverage.
Collapse
Affiliation(s)
| | - Artur Lorens
- Implant and Auditory Perception Department, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
| | - Elzbieta Gos
- Teleaudiology and Screening Department, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
| | - Aleksandra Kolodziejak
- Teleaudiology and Screening Department, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
| | - Anita Obrycka
- Implant and Auditory Perception Department, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
| | - Magdalena B Skarżyńska
- Institute of Sensory Organs, Warsaw, Poland
- Center of Hearing and Speech Medincus, Warsaw, Poland
- Pharmacy Department, Department of Pharmacotherapy and Pharmaceutical Care, Medical University of Warsaw, Warsaw, Poland
| | - Natalia Czajka
- Teleaudiology and Screening Department, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
| | - Marek Porowski
- Otorhinolaryngosurgery Clinic, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
| | - Henryk Skarzynski
- Otorhinolaryngosurgery Clinic, World Hearing Center, Institute of Physiology and Pathology of Hearing, Warsaw, Poland
| |
Collapse
|
28
|
Huang Z, Chen S, Zhang G, Almadhor A, Li R, Li M, Abbas M, Nguyen Le B, Zhang J, Huang Y. Nanocatalysts as fast and powerful medical intervention: Bridging cochlear implant therapies and advanced modelling using Hidden Markov Models (HMMs) for effective treatment of infections. ENVIRONMENTAL RESEARCH 2023:116285. [PMID: 37301496 DOI: 10.1016/j.envres.2023.116285] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 05/23/2023] [Accepted: 05/29/2023] [Indexed: 06/12/2023]
Abstract
As human population growth and waste from technologically advanced industries threaten to destabilise our delicate ecological equilibrium, the global spotlight intensifies on environmental contamination and climate-related changes. These challenges extend beyond our external environment and have significant effects on our internal ecosystems. The inner ear, which is responsible for balance and auditory perception, is a prime example. When these sensory mechanisms are impaired, disorders such as deafness can develop. Traditional treatment methods, including systemic antibiotics, are frequently ineffective due to inadequate inner ear penetration. Conventional techniques for administering substances to the inner ear fail to obtain adequate concentrations as well. In this context, cochlear implants laden with nanocatalysts emerge as a promising strategy for the targeted treatment of inner ear infections. Coated with biocompatible nanoparticles containing specific nanocatalysts, these implants can degrade or neutralise contaminants linked to inner ear infections. This method enables the controlled release of nanocatalysts directly at the infection site, thereby maximising therapeutic efficacy and minimising adverse effects. In vivo and in vitro studies have demonstrated that these implants are effective at eliminating infections, reducing inflammation, and fostering tissue regeneration in the ear. This study investigates the application of hidden Markov models (HMMs) to nanocatalyst-loaded cochlear implants. The HMM is trained on surgical phases in order to accurately identify the various phases associated with implant utilisation. This facilitates the precision placement of surgical instruments within the ear, with a location accuracy between 91% and 95% and a standard deviation between 1% and 5% for both sites. In conclusion, nanocatalysts serve as potent medicinal instruments, bridging cochlear implant therapies and advanced modelling utilising hidden Markov models for the effective treatment of inner ear infections. Cochlear implants loaded with nanocatalysts offer a promising method to combat inner ear infections and enhance patient outcomes by addressing the limitations of conventional treatments.
Collapse
|
29
|
Paouris D, Kunzo S, Goljerová I. Validation of Automatic Cochlear Measurements Using OTOPLAN ® Software. J Pers Med 2023; 13:jpm13050805. [PMID: 37240975 DOI: 10.3390/jpm13050805] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 05/02/2023] [Accepted: 05/05/2023] [Indexed: 05/28/2023] Open
Abstract
INTRODUCTION Electrode length selection based on case-related cochlear parameters is becoming a standard pre-operative step for cochlear implantation. The manual measurement of the parameters is often time-consuming and may lead to inconsistencies. Our work aimed to evaluate a novel, automatic measurement method. MATERIALS AND METHODS A retrospective evaluation of pre-operative HRCT images of 109 ears (56 patients) was conducted, using a development version of the OTOPLAN® software. Inter-rater (intraclass) reliability and execution time were assessed for manual (surgeons R1 and R2) vs. automatic (AUTO) results. The analysis included A-Value (Diameter), B-Value (Width), H-Value (Height), and CDLOC-length (Cochlear Duct Length at Organ of Corti/Basilar membrane). RESULTS The measurement time was reduced from approximately 7 min ± 2 (min) (manual) to 1 min (AUTO). Cochlear parameters in mm (mean ± SD) for R1, R2 and AUTO, respectively, were A-value: 9.00 ± 0.40, 8.98 ± 0.40 and 9.16 ± 0.36; B-value: 6.81 ± 0.34, 6.71 ± 0.35 and 6.70 ± 0.40; H-value: 3.98 ± 0.25, 3.85 ± 0.25 and 3.76 ± 0.22; and the mean CDLoc-length: 35.64 ± 1.70, 35.20 ± 1.71 and 35.47 ± 1.87. AUTO CDLOC measurements were not significantly different compared to R1 and R2 (H0: Rx CDLOC = AUTO CDLOC: p = 0.831, p = 0.242, respectively), and the calculated intraclass correlation coefficient (ICC) for CDLOC was 0.9 (95% CI: 0.85, 0.932) for R1 vs. AUTO; 0.90 (95% CI: 0.85, 0.932) for R2 vs. AUTO; and 0.893 (95% CI: 0.809, 0.935) for R1 vs. R2. CONCLUSIONS We observed excellent inter-rater reliability, a high agreement of outcomes, and reduced execution time using the AUTO method.
Collapse
Affiliation(s)
- Dimitrios Paouris
- Clinic of Pediatric Otorhinolaryngology of the Medical Faculty, National Institute of Children's Diseases, Comenius University, 83340 Bratislava, Slovakia
| | - Samuel Kunzo
- Clinic of Pediatric Otorhinolaryngology of the Medical Faculty, National Institute of Children's Diseases, Comenius University, 83340 Bratislava, Slovakia
| | - Irina Goljerová
- Clinic of Pediatric Otorhinolaryngology of the Medical Faculty, National Institute of Children's Diseases, Comenius University, 83340 Bratislava, Slovakia
| |
Collapse
|
30
|
Weiss N. [Cochlear implantation - Adverse effects on the cochlea and the vestibular organ]. Laryngorhinootologie 2023; 102:381-389. [PMID: 37141880 DOI: 10.1055/a-1961-5815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Cochlear implantation is the treatment of choice for patients with profound hearing loss and deafness. At the same time, inserting a cochlear implant (CI) leaves damage to the inner ear. The preservation of inner ear structure and function has become a central issue in CI surgery. The reasons for this are i) electroacoustic stimulation (EAS), i.e., the option of joint stimulation by a hearing aid and a CI; ii) an improved audiologic outcome in electric-only stimulation; iii) the preservation of structures and residual hearing for potential future therapy options; and iv) the avoidance of side effects, such as vertigo. The exact mechanisms that determine the extent of damage to the inner ear and which factors contribute to preservation of residual hearing are not yet fully understood. In addition to the surgical technique, electrode selection may play a role. This article provides an overview of what is known about the direct and indirect adverse effects of cochlear implantation on the inner ear, of the methods available to monitor inner ear function during cochlear implantation, and of the focus of future research on preservation of inner ear structure and function.
Collapse
|
31
|
Schurzig D, Repp F, Timm ME, Batsoulis C, Lenarz T, Kral A. Virtual cochlear implantation for personalized rehabilitation of profound hearing loss. Hear Res 2023; 429:108687. [PMID: 36638762 DOI: 10.1016/j.heares.2022.108687] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 12/09/2022] [Accepted: 12/26/2022] [Indexed: 12/28/2022]
Abstract
In cochlear implantation, current preoperative planning procedures allow for estimating how far a specific implant will reach into the inner ear of the patient, which is important to optimize hearing preservation and speech perception outcomes. Here we report on the development of a methodology that goes beyond current planning approaches: the proposed model does not only estimate specific outcome parameters but allows for entire, three-dimensional virtual implantations of patient-specific cochlear anatomies with different types of electrode arrays. The model was trained based on imaging datasets of 186 human cochleae, which contained 171 clinical computer tomographies (CTs) of actual cochlear implant patients as well as 15 high-resolution micro-CTs of cadaver cochleae to also reconstruct the refined intracochlear structures not visible in clinical imaging. The model was validated on an independent dataset of 141 preoperative and postoperative clinical CTs of cochlear implant recipients and outperformed all currently available planning approaches, not only in terms of accuracy but also regarding the amount of information that is available prior to the actual implantation.
Collapse
Affiliation(s)
- Daniel Schurzig
- Institute of AudioNeuroTechnology & Department of Experimental Otology, ENT Department, Hannover Medical School, Hannover, Germany; MED-EL Research Center, Hannover, Germany.
| | | | - Max E Timm
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | | | - Thomas Lenarz
- Institute of AudioNeuroTechnology & Department of Experimental Otology, ENT Department, Hannover Medical School, Hannover, Germany; Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - Andrej Kral
- Institute of AudioNeuroTechnology & Department of Experimental Otology, ENT Department, Hannover Medical School, Hannover, Germany; Department of Otolaryngology, Hannover Medical School, Hannover, Germany; Department of Biomedical Sciences, Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
32
|
Warnecke A, Staecker H, Rohde E, Gimona M, Giesemann A, Szczepek AJ, Di Stadio A, Hochmair I, Lenarz T. Extracellular Vesicles in Inner Ear Therapies-Pathophysiological, Manufacturing, and Clinical Considerations. J Clin Med 2022; 11:jcm11247455. [PMID: 36556073 PMCID: PMC9788356 DOI: 10.3390/jcm11247455] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/09/2022] [Accepted: 12/11/2022] [Indexed: 12/23/2022] Open
Abstract
(1) Background: Sensorineural hearing loss is a common and debilitating condition. To date, comprehensive pharmacologic interventions are not available. The complex and diverse molecular pathology that underlies hearing loss may limit our ability to intervene with small molecules. The current review foccusses on the potential for the use of extracellular vesicles in neurotology. (2) Methods: Narrative literature review. (3) Results: Extracellular vesicles provide an opportunity to modulate a wide range of pathologic and physiologic pathways and can be manufactured under GMP conditions allowing for their application in the human inner ear. The role of inflammation in hearing loss with a focus on cochlear implantation is shown. How extracellular vesicles may provide a therapeutic option for complex inflammatory disorders of the inner ear is discussed. Additionally, manufacturing and regulatory issues that need to be addressed to develop EVs as advanced therapy medicinal product for use in the inner ear are outlined. (4) Conclusion: Given the complexities of inner ear injury, novel therapeutics such as extracellular vesicles could provide a means to modulate inflammation, stress pathways and apoptosis in the inner ear.
Collapse
Affiliation(s)
- Athanasia Warnecke
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany
- Cluster of Excellence of the German Research Foundation (DFG; “Deutsche Forschungsgemeinschaft”) “Hearing4all”, 30625 Hannover, Germany
- Correspondence:
| | - Hinrich Staecker
- Department of Otolaryngology Head and Neck Surgery, University of Kansas School of Medicine, Rainbow Blvd., Kansas City, KS 66160, USA
| | - Eva Rohde
- GMP Unit, Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS), Paracelsus Medical University, 5020 Salzburg, Austria
- Transfer Centre for Extracellular Vesicle Theralytic Technologies (EV-TT), 5020 Salzburg, Austria
- Department of Transfusion Medicine, University Hospital, Salzburger Landeskliniken GesmbH (SALK) Paracelsus Medical University, 5020 Salzburg, Austria
| | - Mario Gimona
- GMP Unit, Spinal Cord Injury & Tissue Regeneration Centre Salzburg (SCI-TReCS), Paracelsus Medical University, 5020 Salzburg, Austria
- Transfer Centre for Extracellular Vesicle Theralytic Technologies (EV-TT), 5020 Salzburg, Austria
- Research Program “Nanovesicular Therapies”, Paracelsus Medical University, 5020 Salzburg, Austria
| | - Anja Giesemann
- Department of Diagnostic and Interventional Neuroradiology, Hannover Medical School, Carl-Neuberg-Str. 1, 30625 Hannover, Germany
| | - Agnieszka J. Szczepek
- Department of Otorhinolaryngology, Head and Neck Surgery, Charité-Universitätsmedizin Berlin, 10117 Berlin, Germany
- Faculty of Medicine and Health Sciences, University of Zielona Gora, 65-046 Zielona Gora, Poland
| | - Arianna Di Stadio
- Department GF Ingrassia, University of Catania, 95124 Catania, Italy
| | | | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, 30625 Hannover, Germany
- Cluster of Excellence of the German Research Foundation (DFG; “Deutsche Forschungsgemeinschaft”) “Hearing4all”, 30625 Hannover, Germany
| |
Collapse
|
33
|
Hoffmann JAC, Warnecke A, Timm ME, Kludt E, Prenzler NK, Gärtner L, Lenarz T, Salcher RB. Cochlear Implantation in Obliterated Cochlea: A Retrospective Analysis and Comparison between the IES Stiff Custom-Made Device and the Split-Array and Regular Electrodes. J Clin Med 2022; 11:jcm11206090. [PMID: 36294411 PMCID: PMC9605638 DOI: 10.3390/jcm11206090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/12/2022] [Accepted: 10/13/2022] [Indexed: 11/07/2022] Open
Abstract
Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.
Collapse
Affiliation(s)
| | - Athanasia Warnecke
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Max Eike Timm
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Eugen Kludt
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Nils Kristian Prenzler
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Lutz Gärtner
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Thomas Lenarz
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
| | - Rolf Benedikt Salcher
- Department of Otorhinolaryngology, Head and Neck Surgery, Hannover Medial School, 30625 Hannover, Germany
- Cluster of Excellence “Hearing4all”, Hannover Medical School, 30625 Hannover, Germany
- Correspondence:
| |
Collapse
|
34
|
Topsakal V, Agrawal S, Atlas M, Baumgartner WD, Brown K, Bruce IA, Dazert S, Hagen R, Lassaletta L, Mlynski R, Raine CH, Rajan GP, Schmutzhard J, Sprinzl GM, Staecker H, Usami SI, Van Rompaey V, Zernotti M, van de Heyning P. Minimally Traumatic Cochlear Implant Surgery: Expert Opinion in 2010 and 2020. J Pers Med 2022; 12:jpm12101551. [PMID: 36294690 PMCID: PMC9605439 DOI: 10.3390/jpm12101551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/14/2022] [Accepted: 09/17/2022] [Indexed: 12/03/2022] Open
Abstract
This study aimed to discover expert opinion on the surgical techniques and materials most likely to achieve maximum postoperative residual hearing preservation in cochlear implant (CI) surgery and to determine how these opinions have changed since 2010. A previously published questionnaire used in a study published in 2010 was adapted and expanded. The questionnaire was distributed to an international group of experienced CI surgeons. Present results were compared, via descriptive statistics, to those from the 2010 survey. Eighteen surgeons completed the questionnaire. Respondents clearly favored the following: round window insertion, slow array insertion, and the peri- and postoperative use of systematic antibiotics. Insertion depth was regarded as important, and electrode arrays less likely to induce trauma were preferred. The usefulness of dedicated soft-surgery training was also recognized. A lack of agreement was found on whether the middle ear cavity should be flushed with a non-aminoglycoside antibiotic solution or whether a sheath or insertion tube should be used to avoid contaminating the array with blood or bone dust. In conclusion, this paper demonstrates how beliefs about CI soft surgery have changed since 2010 and shows areas of current consensus and disagreement.
Collapse
Affiliation(s)
- Vedat Topsakal
- Department of Otorhinolaryngology, Head and Neck Surgery, Brussels Health Campus, University Hospital Brussels (UZ Brussel), Vrije Universiteit Brussel (VUB), 1090 Jette, Belgium
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital (UZA), University of Antwerp, 2610 Edegem, Belgium
- Correspondence: ; Tel.: +32-2477-6882; Fax: +32-2477-6880
| | - Sumit Agrawal
- London Canada Health Sciences Centre, Department of Otolaryngology–Head & Neck Surgery, Western University, London, ON N6G 2M3, Canada
| | - Marcus Atlas
- Ear Science Institute Australia, Subiaco, WA 6008, Australia
| | | | - Kevin Brown
- UNC Ear & Hearing Center at Chapel Hill School of Medicine, Chapel Hill, NC 27599, USA
| | - Iain A. Bruce
- Royal Manchester Children’s Hospital, Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester M13 9WL, UK
- Division of Infection, Immunity and Respiratory Medicine, Faculty of Biology, Medicine and Health, University of Manchester, Manchester M15 6JA, UK
| | - Stefan Dazert
- St. Elisabeth Hospital, Ruhr University Bochum, 44787 Bochum, Germany
| | - Rudolf Hagen
- Würzburg ENT University Hospital, 97080 Würzburg, Germany
| | | | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery “Otto Körner”, Rostock University Medical Center, 18057 Rostock, Germany
| | - Christopher H. Raine
- Bradford Royal Infirmary Yorkshire Auditory Implant Service, Bradford BD9 6RJ, UK
| | | | - Joachim Schmutzhard
- Department of Otorhinolaryngology-Head and Neck Surgery, Medical University of Innsbruck, 6020 Innsbruck, Austria
| | | | - Hinrich Staecker
- Department of Otolaryngology-Head & Neck Surgery, University of Kansas Medical Center, Kansas City, KS 66160, USA
| | - Shin-ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Matsumoto 390-8621, Japan
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital (UZA), University of Antwerp, 2610 Edegem, Belgium
| | | | - Paul van de Heyning
- Department of Otorhinolaryngology, Head and Neck Surgery, Antwerp University Hospital (UZA), University of Antwerp, 2610 Edegem, Belgium
| |
Collapse
|
35
|
Herrmann DP, Müller-Graff FT, Kaulitz S, Cebulla M, Kurz A, Hagen R, Neun T, Rak K. Application of intentional facial nerve stimulation during cochlear implantation as an electrophysiological tool to estimate the intracochlear electrode position. Sci Rep 2022; 12:13426. [PMID: 35927465 PMCID: PMC9352782 DOI: 10.1038/s41598-022-17732-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2021] [Accepted: 07/29/2022] [Indexed: 11/17/2022] Open
Abstract
This proof of concept describes the use of evoked electromyographic (EMG) activation of the facial nerve for intraoperative monitoring of the electrode insertion during cochlear implantation (CI). Intraoperative EMG measurements from the facial nerve were conducted in nine patients undergoing CI implantation. Electric current pulses were emitted from contacts on the CI array during and immediately after electrode insertion. For control, the results of EMG measurements were compared to postoperative flat panel volume computed tomography scans with secondary reconstruction (fpVCTSECO). During insertion, the EMG response evoked by the electrical stimulation from the CI was growing with the stimulating contact approaching the facial nerve and declined with increasing distance. After full insertion, contacts on the apical half of the CI array stimulated higher EMG responses compared with those on the basal half. Comparison with postoperative imaging demonstrated that electrode contacts stimulating high EMG responses had the shortest distances to the facial nerve. It could be demonstrated that electrically evoked EMG activation of the facial nerve can be used to monitor the progress during CI electrode insertion and to control the intracochlear electrode position after full insertion.
Collapse
Affiliation(s)
- David P Herrmann
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Franz-Tassilo Müller-Graff
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Stefan Kaulitz
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Mario Cebulla
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Anja Kurz
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Rudolf Hagen
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Tilmann Neun
- Department of Diagnostic and Interventional Neuroradiology, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany
| | - Kristen Rak
- Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Str. 11, 97080, Wuerzburg, Germany.
| |
Collapse
|
36
|
Illg A, Lenarz T. Cochlear Implantation in Hearing-Impaired Elderly: Clinical Challenges and Opportunities to Optimize Outcome. Front Neurosci 2022; 16:887719. [PMID: 35903809 PMCID: PMC9315238 DOI: 10.3389/fnins.2022.887719] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Accepted: 06/14/2022] [Indexed: 11/13/2022] Open
Abstract
Cochlear implant (CI) overall provides a very good outcome, but speech comprehension outcome in the elderly is more variable. Several clinical factors play an important role. The management of residual hearing, the presence of comorbidities, and especially the progression of cognitive decline seem to be the clinical parameters that strongly determine the outcome of cochlear implantation and need to be discussed prospectively in the consultation process with the elderly hearing impaired. In the context of this review article, strategies for dealing with these will be discussed. Timely cochlear implantation should already be considered by hearing aid acousticians or practicing otolaryngologists and communicated or initiated with the patient. This requires intensive cooperation between hearing aid acousticians and experts in the clinic. In addition, residual hearing and comorbidities in the elderly need to be considered to make realistic predictions about speech comprehension with CI. Long-term aftercare and its different implementations should be discussed preoperatively, so that the elderly person with hearing impairments feels well taken care of together with his or her relatives. Elderly patients with hearing impairments benefit most from a CI in terms of speech comprehension if there is a large cochlear coverage (electrical or acoustic electrical) and the therapy is not hampered by comorbidities, especially cognitive decline.
Collapse
Affiliation(s)
- Angelika Illg
- Department of Otolaryngology, Hannover Medical School, Hanover, Germany
| | | |
Collapse
|
37
|
Ertas YN, Ozpolat D, Karasu SN, Ashammakhi N. Recent Advances in Cochlear Implant Electrode Array Design Parameters. MICROMACHINES 2022; 13:1081. [PMID: 35888898 PMCID: PMC9323156 DOI: 10.3390/mi13071081] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 06/29/2022] [Accepted: 06/30/2022] [Indexed: 02/04/2023]
Abstract
Cochlear implants are neural implant devices that aim to restore hearing in patients with severe sensorineural hearing impairment. Here, the main goal is to successfully place the electrode array in the cochlea to stimulate the auditory nerves through bypassing damaged hair cells. Several electrode and electrode array parameters affect the success of this technique, but, undoubtedly, the most important one is related to electrodes, which are used for nerve stimulation. In this paper, we provide a comprehensive resource on the electrodes currently being used in cochlear implant devices. Electrode materials, shape, and the effect of spacing between electrodes on the stimulation, stiffness, and flexibility of electrode-carrying arrays are discussed. The use of sensors and the electrical, mechanical, and electrochemical properties of electrode arrays are examined. A large library of preferred electrodes is reviewed, and recent progress in electrode design parameters is analyzed. Finally, the limitations and challenges of the current technology are discussed along with a proposal of future directions in the field.
Collapse
Affiliation(s)
- Yavuz Nuri Ertas
- Department of Biomedical Engineering, Erciyes University, Kayseri 38039, Turkey; (D.O.); (S.N.K.)
- ERNAM—Nanotechnology Research and Application Center, Erciyes University, Kayseri 38039, Turkey
| | - Derya Ozpolat
- Department of Biomedical Engineering, Erciyes University, Kayseri 38039, Turkey; (D.O.); (S.N.K.)
- ERNAM—Nanotechnology Research and Application Center, Erciyes University, Kayseri 38039, Turkey
| | - Saime Nur Karasu
- Department of Biomedical Engineering, Erciyes University, Kayseri 38039, Turkey; (D.O.); (S.N.K.)
- ERNAM—Nanotechnology Research and Application Center, Erciyes University, Kayseri 38039, Turkey
| | - Nureddin Ashammakhi
- Institute for Quantitative Health Science and Engineering (IQ) and Department of Biomedical Engineering (BME), Michigan State University, East Lansing, MI 48824, USA
| |
Collapse
|
38
|
Scheunemann CWD, Taeger J, Brecht SV, Neun T, Hagen R, Lueth TC, Rak KJ. Concept and first Implementation of an intracochlearly navigated Electrode Array for Cochlear Implantation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:2560-2564. [PMID: 36085908 DOI: 10.1109/embc48229.2022.9871850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Cochlear implants (CI) are an established treatment for people with deafness or severe hearing loss. To restore patients' hearing an electrode array (EA) of the CI is inserted into the cochlea to stimulate the auditory nerve. Thereby, the exact positioning and gentle insertion of the EA is crucial for optimal hearing perception outcome. Currently, only microscopic vision is available for entering the cochlea, but the critical intracochlear process during EA insertion is like a "black box" and the surgeon has to rely on haptic feedback. Methods for visualizing the insertion process during surgery are inaccurate or not suitable for routine use due to radiation exposure. To address this problem, we developed a computer-assisted and image-guided cochlear implantation system with an exact real-time visualization of the EA position during the insertion process. The system is based on an electromagnetic tracking system that measures the position and orientation of a sensor integrated into the tip of a EA prototype and visualizes it in presurgical image data. A first experiment with our system showed that a EA prototype could be inserted into a cochlea of a human temporal bone and placed with an accuracy of [Formula: see text]. A maximum insertion angle of 120° was achieved.
Collapse
|
39
|
Van de Heyning PH, Dazert S, Gavilan J, Lassaletta L, Lorens A, Rajan GP, Skarzynski H, Skarzynski PH, Tavora-Vieira D, Topsakal V, Usami SI, Van Rompaey V, Weiss NM, Polak M. Systematic Literature Review of Hearing Preservation Rates in Cochlear Implantation Associated With Medium- and Longer-Length Flexible Lateral Wall Electrode Arrays. Front Surg 2022; 9:893839. [PMID: 36034377 PMCID: PMC9407249 DOI: 10.3389/fsurg.2022.893839] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 05/30/2022] [Indexed: 11/13/2022] Open
Abstract
BackgroundThe last two decades have demonstrated that preoperative functional acoustic hearing (residual hearing) can be preserved during cochlear implant (CI) surgery. However, the relationship between the electrode array length and postoperative hearing preservation (HP) with lateral wall flexible electrode variants is still under debate.Aims/ObjectivesThis is a systematic literature review that aims to analyze the HP rates of patients with residual hearing for medium-length and longer-length lateral wall electrodes.MethodA systematic literature review methodology was applied following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) recommendations to evaluate the HP rates of medium-length and longer-length lateral wall electrodes from one CI manufacturer (medium length FLEX 24, longer length FLEX 28 and FLEX SOFT, MED-EL, Innsbruck, Austria). A search using search engine PubMed (https://www.ncbi.nlm.nih.gov/pubmed/) was performed using the search terms “hearing preservation” or “residual hearing” and “cochlear implant” in “All fields.” Articles published only in English between January 01, 2009 and December 31, 2020 were included in the search.ResultsThe HP rate was similar between medium-length (93.4%–93.5%) and longer (92.1%–86.8%) electrodes at 4 months (p = 0.689) and 12 months (p = 0.219). In the medium-length electrode group, patients under the age of 45 years had better HP than patients above the age of 45 years.ConclusionsBoth medium-length and longer electrode arrays showed high hearing preservation rates. Considering the hearing deterioration over time, implanting a longer electrode at primary surgery should be considered, thus preventing the need for future reimplantation.
Collapse
Affiliation(s)
- Paul H Van de Heyning
- Department of Otorhinolaryngology and Head and Neck Surgery, Antwerp University Hospital, Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
- Correspondence: Paul H Van de Heyning
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | - Javier Gavilan
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| | - Luis Lassaletta
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
- Biomedical Research Networking Centre on Rare Diseases (CIBERER), Institute of Health Carlos, III, (CIBERER-U761), Madrid, Spain
| | - Artur Lorens
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Gunesh P Rajan
- Department of Otolaryngology, Head and Neck Surgery, Luzerner Kantonsspital, Luzern
- Department of Health Sciences and Medicine, University of Lucerne, Luzern, Switzerland
- Otolaryngology, Head & Neck Surgery, Division of Surgery, Medical School University of Western Australia, Perth, Australia
| | - Henryk Skarzynski
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Piotr H Skarzynski
- World Hearing Center, Institute of Physiology and Pathology of Hearing, Kajetany, Poland
- Heart Failure and Cardiac Rehabilitation Department, Medical University of Warsaw, Warsaw, Poland
- Institute of Sensory Organs, Kajetany, Poland
| | - Dayse Tavora-Vieira
- Otolaryngology, Head & Neck Surgery, Division of Surgery, Medical School University of Western Australia, Perth, Australia
- Audiology Department, Fiona Stanley Fremantle Hospitals Group, Perth, WA, Australia
| | - Vedat Topsakal
- Department of Otorhinolaryngology and Head and Neck Surgery, University Hospital Brussels, Vrije Universiteit Brussel, Brussels Health Campus, Belgium
| | - Shin-ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Matsumoto, Nagano, Japan
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology and Head and Neck Surgery, Antwerp University Hospital, Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Nora M Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | - Marek Polak
- Department of Electrophysiology, R&D, MED-EL, Innsbruck, Austria
| |
Collapse
|
40
|
Rau TS, Ehmann T, Zuniga MG, Plaskonka K, Keck A, Majdani O, Lenarz T. Toward a cochlear implant electrode array with shape memory effect for post-insertion perimodiolar positioning. J Biomed Mater Res B Appl Biomater 2022; 110:2494-2505. [PMID: 35678249 DOI: 10.1002/jbm.b.35107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Revised: 05/16/2022] [Accepted: 05/20/2022] [Indexed: 11/08/2022]
Abstract
For cochlear implants (CI) a final position of the electrode array (EA) along the inner wall of the spirally shaped cochlea is considered to be beneficial because it results in a closer proximity to the auditory nerve fibers. A shape memory effect (SME) could facilitate such shift of the EA toward the cochlear inner wall, but its implementation remains to be solved. The current study presents an EA prototype featuring the SME with minute adjustments of the material properties of Nitinol, a shape memory alloy, in combination with a suitable cooling strategy to prevent premature curling. Ten samples were successfully inserted by a CI surgeon into an artificial cochlear model submerged into a temperature-controllable water bath to simulate temporary hypothermia of the inner ear (31°C). Gentle insertions were possible, with an average insertion speed of 0.81 ± 0.14 mm/s. After recovery of body temperature, the desired position shift toward the modiolus was observed in all trials. Angular insertion depth increased by approximately 81.8° ± 23.4°. We demonstrate for the first time that using the body temperature responsive SME for perimodiolar EA positioning is feasible and does not impede a gentle surgical insertion.
Collapse
Affiliation(s)
- Thomas S Rau
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence EXC 2177/1 "Hearing4all", Hannover Medical School, Hannover, Germany
| | - Tim Ehmann
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany
| | - M Geraldine Zuniga
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence EXC 2177/1 "Hearing4all", Hannover Medical School, Hannover, Germany
| | | | | | - Omid Majdani
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence EXC 2177/1 "Hearing4all", Hannover Medical School, Hannover, Germany
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany.,Cluster of Excellence EXC 2177/1 "Hearing4all", Hannover Medical School, Hannover, Germany
| |
Collapse
|
41
|
Dillon MT, O'Connell BP, Canfarotta MW, Buss E, Hopfinger J. Effect of Place-Based Versus Default Mapping Procedures on Masked Speech Recognition: Simulations of Cochlear Implant Alone and Electric-Acoustic Stimulation. Am J Audiol 2022; 31:322-337. [PMID: 35394798 DOI: 10.1044/2022_aja-21-00123] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE Cochlear implant (CI) recipients demonstrate variable speech recognition when listening with a CI-alone or electric-acoustic stimulation (EAS) device, which may be due in part to electric frequency-to-place mismatches created by the default mapping procedures. Performance may be improved if the filter frequencies are aligned with the cochlear place frequencies, known as place-based mapping. Performance with default maps versus an experimental place-based map was compared for participants with normal hearing when listening to CI-alone or EAS simulations to observe potential outcomes prior to initiating an investigation with CI recipients. METHOD A noise vocoder simulated CI-alone and EAS devices, mapped with default or place-based procedures. The simulations were based on an actual 24-mm electrode array recipient, whose insertion angles for each electrode contact were used to estimate the respective cochlear place frequency. The default maps used the filter frequencies assigned by the clinical software. The filter frequencies for the place-based maps aligned with the cochlear place frequencies for individual contacts in the low- to mid-frequency cochlear region. For the EAS simulations, low-frequency acoustic information was filtered to simulate aided low-frequency audibility. Performance was evaluated for the AzBio sentences presented in a 10-talker masker at +5 dB signal-to-noise ratio (SNR), +10 dB SNR, and asymptote. RESULTS Performance was better with the place-based maps as compared with the default maps for both CI-alone and EAS simulations. For instance, median performance at +10 dB SNR for the CI-alone simulation was 57% correct for the place-based map and 20% for the default map. For the EAS simulation, those values were 59% and 37% correct. Adding acoustic low-frequency information resulted in a similar benefit for both maps. CONCLUSIONS Reducing frequency-to-place mismatches, such as with the experimental place-based mapping procedure, produces a greater benefit in speech recognition than maximizing bandwidth for CI-alone and EAS simulations. Ongoing work is evaluating the initial and long-term performance benefits in CI-alone and EAS users. SUPPLEMENTAL MATERIAL https://doi.org/10.23641/asha.19529053.
Collapse
Affiliation(s)
- Margaret T. Dillon
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill
- Division of Speech and Hearing Sciences, Department of Allied Health Sciences, University of North Carolina at Chapel Hill
| | - Brendan P. O'Connell
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill
| | - Michael W. Canfarotta
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill
| | - Emily Buss
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill
| | - Joseph Hopfinger
- Department of Psychology and Neuroscience, University of North Carolina at Chapel Hill
| |
Collapse
|
42
|
Landsberger DM, Stupak N, Spitzer ER, Entwisle L, Mahoney L, Waltzman SB, McMenomey S, Friedmann DR, Svirsky MA, Shapiro W, Roland JT. Stimulating the Cochlear Apex Without Longer Electrodes: Preliminary Results With a New Approach. Otol Neurotol 2022; 43:e578-e581. [PMID: 35283466 PMCID: PMC9149041 DOI: 10.1097/mao.0000000000003529] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To investigate a new surgical and signal processing technique that provides apical stimulation of the cochlea using a cochlear implant without extending the length of the electrode array. PATIENTS Three adult patients who underwent cochlear implantation using this new technique. INTERVENTIONS The patients received a cochlear implant. The surgery differed from the standard approach in that a ground electrode was placed in the cochlear helicotrema via an apical cochleostomy rather than in its typical location underneath the temporalis muscle. Clinical fitting was modified such that low frequencies were represented using the apically placed electrode as a ground. MAIN OUTCOME MEASURES Pitch scaling and speech recognition. RESULTS All surgeries were successful with no complications. Pitch scaling demonstrated that use of the apically placed electrode as a ground lowered the perceived pitch of electric stimulation relative to monopolar stimulation. Speech understanding was improved compared with preoperative scores. CONCLUSIONS The new surgical approach and clinical fitting are feasible. A lower pitch is perceived when using the apically placed electrode as a ground relative to stimulation using an extracochlear ground (i.e., monopolar mode), suggesting that stimulation can be provided more apically without the use of a longer electrode array. Further work is required to determine potential improvements in outcomes and optimal signal processing for the new approach.
Collapse
Affiliation(s)
- David M Landsberger
- Department of Otolaryngology, New York University Grossman School of Medicine, New York, New York
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Wu CN, Yang CH, Huang PC, Huang YW, Hwang CF. Clinical significance of the neural response telemetric thresholds in Mandarin-speaking cochlear implant patients. J Chin Med Assoc 2022; 85:478-483. [PMID: 35286292 DOI: 10.1097/jcma.0000000000000707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND It is unclear whether neural response telemetric (NRT) thresholds are related to lexical tonal language performance after cochlear implants (CIs). We explored the factors associated with changes in NRT thresholds and postoperative performance of CI patients. METHODS Patients receiving nucleus 24 CIs in our hospital from November 2010 were enrolled. We analyzed medical records and NRT thresholds. Mandarin speech and tone identification were measured in CI patients for at least 1 year postoperatively. RESULTS Seventy-two patients with an average age of 16.1 years received CIs. The postoperative NRT threshold was lower than the intraoperative threshold. The NRT threshold was higher in the early- than the late-activation group (mapping within 21 vs >21 days postoperatively, respectively). Lower intraoperative NRT thresholds and curved electrodes were significantly associated with lower postoperative NRT thresholds. In multiple linear regression analysis, only postoperative NRT thresholds significantly affected speech and tone perception, including word recognition scores, tone perception, and comprehension of easy and difficult sentences (all p < 0.05). Other clinical parameters, including age, gender, implant type, and activation timing, were not significantly associated with clinical tone or speech outcomes. CONCLUSION Curved electrode arrays were associated with lower postoperative NRT thresholds. A lower postoperative NRT threshold might predict better performance of Mandarin-speaking CI patients. Future studies should evaluate factors that affect both postoperative NRT thresholds and lexical tonal language performance.
Collapse
Affiliation(s)
- Ching-Nung Wu
- Department of Otolaryngology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, ROC
| | - Chao-Hui Yang
- Department of Otolaryngology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, ROC
| | - Ping-Che Huang
- Department of Speech Language Pathology and Audiology, Chung Shan Medical University, Taichung, Taiwan, ROC
| | - Yi-Wen Huang
- Department of Medicine, Shan Medical University, Taichung, Taiwan, ROC
| | - Chung-Feng Hwang
- Department of Otolaryngology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan, ROC
| |
Collapse
|
44
|
Walia A, Shew MA, Ettyreddy A, Lefler SM, Jiramongkolchai P, Wick CC, Durakovic N, Buchman CA, Herzog JA. Early Hearing Preservation Outcomes Following Cochlear Implantation With New Slim Lateral Wall Electrode Using Electrocochleography. Otol Neurotol 2022; 43:443-451. [PMID: 35170555 PMCID: PMC8959404 DOI: 10.1097/mao.0000000000003475] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Describe early hearing preservation (HP) cochlear implantation (CI) outcomes using a new slim lateral wall electrode (SLWE). STUDY DESIGN Prospective cohort study. SETTING Tertiary referral center. PATIENTS Adult CI candidates with preoperative low-frequency pure-tone average (LFPTA; 125, 250, 500 Hz) ≤60 dB HL. INTERVENTION CI with and without intracochlear real-time electrocochleography (RT-ECochG). MAIN OUTCOME MEASURE HP (LFPTA ≤80 dB HL), LFPTA shift, speech-perception performance measures, postoperative CT reconstruction. RESULTS Forty-two subjects were implanted with the SLWE. Thirty patients underwent full insertion without RT-ECochG feedback, and HP was maintained at 3-months postactivation for 7 (23.3%) patients with mean LFPTA shift of 57.5 ± 25.6 dB HL. RT-ECochG feedback was utilized on 12 patients, of whom 6 patients had full insertions and 6 patients had anywhere from 1 to 3 electrodes left outside of the cochlea based on RT-ECochG feedback. At 3 months postoperatively, HP was achieved on 10 (83.3%) patients and mean LFPTA shift was 18.9 c 11.7 dB HL. Mean difference between LFPTA threshold shift at 3-months postactivation with and without RT-ECochG was 38.6 dB HL (95% CI, 25.6-51.67). There was an improvement in delta CNC from preoperative to 3-months postactivation when using RT-ECochG, with mean difference 20.7% (95% CI, 3.3-38.1). CONCLUSIONS Use of RT-ECochG monitoring during SLWE placement results in fewer full electrode insertions and significantly better HP rates and speech-perception outcomes when compared with unmonitored insertions. Further investigation is needed to evaluate long-term audiologic outcomes to better understand the relationships among ECochG, cochlear trauma, functional outcomes, and HP.
Collapse
Affiliation(s)
- Amit Walia
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | - Matthew A. Shew
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | - Abhinav Ettyreddy
- Department of Otolaryngology—Head and Neck Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Shannon M. Lefler
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | - Pawina Jiramongkolchai
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | - Cameron C. Wick
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | - Nedim Durakovic
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | - Craig A. Buchman
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| | - Jacques A. Herzog
- Department of Otolaryngology—Head and Neck Surgery, Washington University School of Medicine in St. Louis, St Louis, Missouri, USA
| |
Collapse
|
45
|
Variations in microanatomy of the human modiolus require individualized cochlear implantation. Sci Rep 2022; 12:5047. [PMID: 35322066 PMCID: PMC8943032 DOI: 10.1038/s41598-022-08731-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2021] [Accepted: 03/10/2022] [Indexed: 11/09/2022] Open
Abstract
Cochlear variability is of key importance for the clinical use of cochlear implants, the most successful neuroprosthetic device that is surgically placed into the cochlear scala tympani. Despite extensive literature on human cochlear variability, few information is available on the variability of the modiolar wall. In the present study, we analyzed 108 corrosion casts, 95 clinical cone beam computer tomographies (CTs) and 15 µCTs of human cochleae and observed modiolar variability of similar and larger extent than the lateral wall variability. Lateral wall measures correlated with modiolar wall measures significantly. ~ 49% of the variability had a common cause. Based on these data we developed a model of the modiolar wall variations and related the model to the design of cochlear implants aimed for perimodiolar locations. The data demonstrate that both the insertion limits relevant for lateral wall damage (approximate range of 4–9 mm) as well as the dimensions required for optimal perimodiolar placement of the electrode (the point of release from the straightener; approximate range of 2–5mm) are highly interindividually variable. The data demonstrate that tip fold-overs of preformed implants likely result from the morphology of the modiolus (with radius changing from base to apex), and that optimal cochlear implantation of perimodiolar arrays cannot be guaranteed without an individualized surgical technique.
Collapse
|
46
|
Canfarotta MW, Dillon MT, Brown KD, Pillsbury HC, Dedmon MM, O'Connell BP. Insertion Depth and Cochlear Implant Speech Recognition Outcomes: A Comparative Study of 28- and 31.5-mm Lateral Wall Arrays. Otol Neurotol 2022; 43:183-189. [PMID: 34772886 PMCID: PMC8752482 DOI: 10.1097/mao.0000000000003416] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVES 1) To compare speech recognition outcomes between cochlear implant (CI) recipients of 28- and 31.5-mm lateral wall electrode arrays, and 2) to characterize the relationship between angular insertion depth (AID) and speech recognition. STUDY DESIGN Retrospective review. SETTING Tertiary academic referral center. PATIENTS Seventy-five adult CI recipients of fully inserted 28-mm (n = 28) or 31.5-mm (n = 47) lateral wall arrays listening with a CI-alone device. INTERVENTIONS Cochlear implantation with postoperative computed tomography. MAIN OUTCOME MEASURES Consonant-nucleus-consonant (CNC) word recognition assessed with the CI-alone at 12 months postactivation. RESULTS The mean AID of the most apical electrode contact for the 31.5-mm array recipients was significantly deeper than the 28-mm array recipients (628° vs 571°, p < 0.001). Following 12 months of listening experience, mean CNC word scores were significantly better for recipients of 31.5-mm arrays compared with those implanted with 28-mm arrays (59.5% vs 48.3%, p = 0.004; Cohen's d = 0.70; 95% CI [0.22, 1.18]). There was a significant positive correlation between AID and CNC word scores (r = 0.372, p = 0.001), with a plateau in performance observed around 600°. CONCLUSIONS Cochlear implant recipients implanted with a 31.5-mm array experienced better speech recognition than those with a 28-mm array at 12 months postactivation. Deeper insertion of a lateral wall array appears to confer speech recognition benefit up to ∼600°, with a plateau in performance observed thereafter. These data provide preliminary evidence of the insertion depth necessary to optimize speech recognition outcomes for lateral wall electrode arrays among CI-alone users.
Collapse
Affiliation(s)
- Michael W Canfarotta
- Department of Otolaryngology/Head and Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | | | | | | | | | | |
Collapse
|
47
|
Lenarz T, Buechner A, Gantz B, Hansen M, Tejani VD, Labadie R, O'Connell B, Buchman CA, Valenzuela CV, Adunka OF, Harris MS, Riggs WJ, Fitzpatrick D, Koka K. Relationship Between Intraoperative Electrocochleography and Hearing Preservation. Otol Neurotol 2022; 43:e72-e78. [PMID: 34739427 PMCID: PMC8671360 DOI: 10.1097/mao.0000000000003403] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
OBJECTIVES To compare intraoperative intracochlear electrocochleography (ECochG) with hearing preservation outcomes in cochlear implant (CI) subjects. DESIGN Intraoperative electrocochleography was performed in adult CI subjects who were recipients of Advanced Bionics' Bionics LLC precurved HiFocus MidScala or straight HiFocus SlimJ electrode arrays. ECochG responses were recorded from the most apical electrode contact during insertion. No changes to the insertions were made due to ECochG monitoring. No information about insertion resistance was collected. ECochG drops were estimated as the change in amplitude from peak (defined as maximum amplitude response) to drop (largest drop) point after the peak during insertion was measured following the peak response. Audiometric thresholds from each subject were obtained before and approximately 1 month after CI surgery. The change in pure tone average for frequencies between 125 Hz and 500 Hz was measured after surgery. No postoperative CT scans were collected as part of this study. RESULTS A total of 68 subjects from five surgical centers participated in the study. The study sample included 30 MidScala and 38 SlimJ electrodes implanted by approximately 20 surgeons who contributed to the study. Although a wide range of results were observed, there was a moderate positive correlation (Pearson Correlation coefficient, r = 0.56, p < 0.01) between the size of the ECochG drop and the magnitude of pure tone average change. This trend was present for both the MidScala and SlimJ arrays. The SlimJ and MidScala arrays produced significantly different hearing loss after surgery. CONCLUSION Large ECochG amplitude drops observed during electrode insertion indicated poorer hearing preservation. Although the outcomes were variable, this information may be helpful to guide surgical decision-making when contemplating full electrode insertion and the likelihood of hearing preservation.
Collapse
Affiliation(s)
- Thomas Lenarz
- Hannover Medical School, Department of Otolaryngology, Hannover, Germany
| | - Andreas Buechner
- Hannover Medical School, Department of Otolaryngology, Hannover, Germany
| | - Bruce Gantz
- University of Iowa, Department of Otolaryngology, Iowa City, Iowa
| | - Marlan Hansen
- University of Iowa, Department of Otolaryngology, Iowa City, Iowa
| | - Viral D Tejani
- University of Iowa, Department of Otolaryngology, Iowa City, Iowa
| | - Robert Labadie
- Vanderbilt University and Medical Center, Department of Otolaryngology, Nashville, Tennessee
| | - Brendan O'Connell
- Charlotte Eye Ear Nose and Throat Associates, P.A., Charlotte, North Carolina
| | - Craig Alan Buchman
- Washington University School of Medicine, Department of Otolaryngology - Head and Neck Surgery, St. Louis, Missouri
| | - Carla V Valenzuela
- Washington University School of Medicine, Department of Otolaryngology - Head and Neck Surgery, St. Louis, Missouri
| | - Oliver F Adunka
- The Ohio State University, Department of Otolaryngology, Columbus, Ohio
| | | | - William J Riggs
- The Ohio State University, Department of Otolaryngology, Columbus, Ohio
| | - Douglas Fitzpatrick
- University of North Carolina at Chapel Hill, Department of Otolaryngology, Chapel Hill, North Carolina
| | - Kanthaiah Koka
- Advanced Bionics LLC, Research and Technology, Valencia, California, USA
| |
Collapse
|
48
|
Vos TG, Brown KD, Buss E, Bucker AL, Dedmon MM, O'Connell BP, Raymond J, Dillon MT. Influence of Postponed Follow-Up after Cochlear Implant Activation during the COVID-19 Pandemic on Aided Sound Field Detection and Speech Recognition. Audiol Neurootol 2021; 27:227-234. [PMID: 34808626 PMCID: PMC8678240 DOI: 10.1159/000519908] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Accepted: 09/20/2021] [Indexed: 11/19/2022] Open
Abstract
INTRODUCTION The objective of this study was to assess the influence of postponing the first post-activation follow-up due to the COVID-19 pandemic on the aided sound field detection thresholds and speech recognition of cochlear implant (CI) users. METHODS A retrospective review was performed at a tertiary referral center. Two groups of adult CI recipients were evaluated: (1) patients whose first post-activation follow-up was postponed due to COVID-19 closures (postponed group; n = 10) and (2) a control group that attended recommended post-activation follow-ups prior to the COVID-19 pandemic (control group; n = 18). For both groups, electric thresholds were estimated at initial activation based on comfort levels and were measured behaviorally at subsequent post-activation follow-ups. For the control group, behavioral thresholds were measured at the 1-month follow-up. For the postponed group, behavioral thresholds were not measured until 3 months post-activation since the 1-month follow-up was postponed. The aided pure-tone average (PTA) and word recognition results were compared between groups at the 3-month follow-up and at an interim visit 2-9 weeks later. RESULTS At the 3-month follow-up, the postponed group had significantly poorer word recognition (23 vs. 42%, p = 0.027) and aided PTA (42 vs. 37 dB HL, p = 0.041) than the control group. No significant differences were observed between 3-month data from the control group and interim data from the postponed group. CONCLUSIONS The postponed follow-up after CI activation was associated with poorer outcomes, both in terms of speech recognition and aided audibility. However, these detrimental effects were reversed following provision of an individualized map, with behaviorally measured electric threshold and comfort levels. While adult CI recipients demonstrate an improvement in speech recognition with estimated electric thresholds, the present results suggest that behavioral mapping within the initial weeks of device use may support optimal outcomes.
Collapse
Affiliation(s)
- Teresa G Vos
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Kevin D Brown
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Emily Buss
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Andrea L Bucker
- Department of Audiology, UNC Health Care, Chapel Hill, North Carolina, USA
| | - Matthew M Dedmon
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Brendan P O'Connell
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| | - Jenna Raymond
- Department of Audiology, UNC Health Care, Chapel Hill, North Carolina, USA
| | - Margaret T Dillon
- Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
| |
Collapse
|
49
|
Taeger J, Müller-Graff FT, Ilgen L, Schendzielorz P, Hagen R, Neun T, Rak K. Cochlear Duct Length Measurements in Computed Tomography and Magnetic Resonance Imaging Using Newly Developed Techniques. OTO Open 2021; 5:2473974X211045312. [PMID: 34595367 PMCID: PMC8477698 DOI: 10.1177/2473974x211045312] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Accepted: 08/15/2021] [Indexed: 11/16/2022] Open
Abstract
Objective Growing interest in measuring the cochlear duct length (CDL) has emerged, since it can influence the selection of cochlear implant electrodes. Currently the measurements are performed with ionized radiation imaging. Only a few studies have explored CDL measurements in magnetic resonance imaging (MRI). Therefore, the presented study aims to fill this gap by estimating CDL in MRI and comparing it with multislice computed tomography (CT). Study Design Retrospective data analyses of 42 cochleae. Setting Tertiary care medical center. Methods Diameter (A value) and width (B value) of the cochlea were measured in HOROS software. The CDL and the 2-turn length were determined by the elliptic circular approximation (ECA). In addition, the CDL, the 2-turn length, and the angular length were determined via HOROS software by the multiplanar reconstruction (MPR) method. Results CDL values were significantly shorter in MRI by MPR (d = 1.38 mm, P < .001) but not by ECA. Similar 2-turn length measurements were significantly lower in MRI by MPR (d = 1.67 mm) and ECA (d = 1.19 mm, both P < .001). In contrast, angular length was significantly higher in MRI (d = 26.79°, P < .001). When the values were set in relation to the frequencies of the cochlea, no clinically relevant differences were estimated (58 Hz at 28-mm CDL). Conclusion In the presented study, CDL was investigated in CT and MRI by using different approaches. Since no clinically relevant differences were found, diagnostics with radiation may be omitted prior to cochlear implantation; thus, a concept of radiation-free cochlear implantation could be established.
Collapse
Affiliation(s)
- Johannes Taeger
- Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Franz Tassilo Müller-Graff
- Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Lukas Ilgen
- Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Phillip Schendzielorz
- Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Rudolf Hagen
- Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| | - Tilman Neun
- Department of Diagnostic and Interventional Neuroradiology, University of Wuerzburg, Wuerzburg, Germany
| | - Kristen Rak
- Department of Oto-rhino-laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Wuerzburg, Germany
| |
Collapse
|
50
|
Cochlear Implantation in Elderly Patients with Residual Hearing. J Clin Med 2021; 10:jcm10194305. [PMID: 34640325 PMCID: PMC8509733 DOI: 10.3390/jcm10194305] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/20/2021] [Accepted: 09/21/2021] [Indexed: 11/30/2022] Open
Abstract
This retrospective study aimed to investigate the range of hearing levels in a cochlear implant (CI) elderly population receiving electric-acoustic-stimulation (EAS) or electric-stimulation (ES) alone. The investigation evaluates the degree of hearing preservation (HP) and the speech comprehension resulting from EAS or ES-only to identify audiometric factors that predict adequate EAS and ES use. We analyzed the pure tone audiometry and speech perception in quiet and noise preoperatively and 12-months after activation of 89 elderly adults (age of 65 years old or older), yielding in total 97 CIs. Thirty-two (33.1%) patients were potential EAS candidates preoperatively, of which 18 patients used EAS at the time of first fitting and the other 14 patients continued to use their residual hearing for EAS at 12-months. Post-treatment, patients with EAS system and ES-only users’ with longer electrodes showed better results in monosyllable word scores in quiet than ES-only users with shorter electrodes. A similar trend was revealed for the speech recognition in noise. Patients with an EAS system benefit from maintaining their natural residual hearing. Nevertheless, strict preoperative patient selection is warranted particularly in elderly patients, in whom the hearing thresholds for EAS indication differ slightly from that in younger adults.
Collapse
|