1
|
Gupta A, Ruminski D, Villar AJ, Toledo RD, Gondek G, Pierscionek B, Artal P, Grulkowski I. Age-related changes in geometry and transparency of human crystalline lens revealed by optical signal discontinuity zones in swept-source OCT images. EYE AND VISION (LONDON, ENGLAND) 2023; 10:46. [PMID: 38037146 PMCID: PMC10691129 DOI: 10.1186/s40662-023-00365-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 10/26/2023] [Indexed: 12/02/2023]
Abstract
BACKGROUND The shape and microstructure of the human crystalline lens alter with ageing, and this has an effect on the optical properties of the eye. The aim of this study was to characterise the age-related differences in the morphology and transparency of the eye lenses of healthy subjects through the optical signal discontinuity (OSD) zones in optical coherence tomography (OCT) images. We also investigated the association of those changes with the optical quality of the eye and visual function. METHODS OCT images of the anterior segment of 49 eyes of subjects (9-78 years) were acquired, and the OSD zones (nucleus, C1-C4 cortical zones) were identified. Central thickness, curvature and optical density were measured. The eye's optical quality was evaluated by the objective scatter index (OSI). Contrast sensitivity and visual acuity tests were performed. The correlation between extracted parameters and age was assessed. RESULTS The increase in lens thickness with age was dominated by the thickening of the cortical zone C3 (0.0146 mm/year). The curvature radii of the anterior lens surface and both anterior and posterior nucleo-cortical interfaces decreased with age (- 0.053 mm/year, - 0.013 mm/year and - 0.006 mm/year, respectively), and no change was observed for the posterior lens radius. OCT-based densitometry revealed significant correlations with age for all zones except for C1β, and the highest increase in density was in the C2-C4 zones (R = 0.45, 0.74, 0.56, respectively, P < 0.001). Increase in OSI was associated with the degradation of visual function. CONCLUSIONS OCT enables the identification of OSD zones of the crystalline lens. The most significant age-related changes occur in the C3 zone as it thickens with age at a faster rate and becomes more opaque than other OSD zones. The changes are associated with optical quality deterioration and reduction of visual performance. These findings contribute to a better understanding of the structure-function relationship of the ageing lens and offer insights into both pathological and aging alterations.
Collapse
Affiliation(s)
- Ashish Gupta
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Daniel Ruminski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Alfonso Jimenez Villar
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Raúl Duarte Toledo
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Universidad de Murcia, Edif. CIOyN, N º34, Campus de Espinardo, 30100, Murcia, Spain
| | - Grzegorz Gondek
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland
| | - Barbara Pierscionek
- Faculty of Health, Education, Medicine, and Social Care, Medical Technology Research Center, Chelmsford Campus, Anglia Ruskin University, Bishop Hall Ln, Chelmsford, CM1 1SQ, UK
| | - Pablo Artal
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Universidad de Murcia, Edif. CIOyN, N º34, Campus de Espinardo, 30100, Murcia, Spain
| | - Ireneusz Grulkowski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University in Toruń, Grudziądzka 5, 87-100, Toruń, Poland.
| |
Collapse
|
2
|
Wadkin LE, Makarenko I, Parker NG, Shukurov A, Figueiredo FC, Lako M. Human Stem Cells for Ophthalmology: Recent Advances in Diagnostic Image Analysis and Computational Modelling. CURRENT STEM CELL REPORTS 2023; 9:57-66. [PMID: 38145008 PMCID: PMC10739444 DOI: 10.1007/s40778-023-00229-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/07/2023] [Indexed: 12/26/2023]
Abstract
Purpose of Review To explore the advances and future research directions in image analysis and computational modelling of human stem cells (hSCs) for ophthalmological applications. Recent Findings hSCs hold great potential in ocular regenerative medicine due to their application in cell-based therapies and in disease modelling and drug discovery using state-of-the-art 2D and 3D organoid models. However, a deeper characterisation of their complex, multi-scale properties is required to optimise their translation to clinical practice. Image analysis combined with computational modelling is a powerful tool to explore mechanisms of hSC behaviour and aid clinical diagnosis and therapy. Summary Many computational models draw on a variety of techniques, often blending continuum and discrete approaches, and have been used to describe cell differentiation and self-organisation. Machine learning tools are having a significant impact in model development and improving image classification processes for clinical diagnosis and treatment and will be the focus of much future research.
Collapse
Affiliation(s)
- L. E. Wadkin
- School of Mathematics, Statistics and Physics, Newcastle University, Newcastle upon Tyne, UK
| | - I. Makarenko
- School of Mathematics, Statistics and Physics, Newcastle University, Newcastle upon Tyne, UK
| | - N. G. Parker
- School of Mathematics, Statistics and Physics, Newcastle University, Newcastle upon Tyne, UK
| | - A. Shukurov
- School of Mathematics, Statistics and Physics, Newcastle University, Newcastle upon Tyne, UK
| | - F. C. Figueiredo
- Department of Ophthalmology, Royal Victoria Infirmary, Newcastle upon Tyne Hospitals NHS Foundation Trust, Newcastle upon Tyne, UK
- Biosciences Institute, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK
| | - M. Lako
- Biosciences Institute, Faculty of Medical Sciences, Newcastle University, Newcastle upon Tyne, UK
| |
Collapse
|
3
|
Vilbert M, Bocheux R, Georgeon C, Borderie V, Pernot P, Irsch K, Plamann K. A new method for in vivo assessment of corneal transparency using spectral-domain OCT. PLoS One 2023; 18:e0291613. [PMID: 37796869 PMCID: PMC10553212 DOI: 10.1371/journal.pone.0291613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 09/02/2023] [Indexed: 10/07/2023] Open
Abstract
Corneal transparency is essential to provide a clear view into and out of the eye, yet clinical means to assess such transparency are extremely limited and usually involve a subjective grading of visible opacities by means of slit-lamp biomicroscopy. Here, we describe an automated algorithm allowing extraction of quantitative corneal transparency parameters with standard clinical spectral-domain optical coherence tomography (SD-OCT). Our algorithm employs a novel pre-processing procedure to standardize SD-OCT image analysis and to numerically correct common instrumental artifacts before extracting mean intensity stromal-depth (z) profiles over a 6-mm-wide corneal area. The z-profiles are analyzed using our previously developed objective method that derives quantitative transparency parameters directly related to the physics of light propagation in tissues. Tissular heterogeneity is quantified by the Birge ratio Br and the photon mean-free path (ls) is determined for homogeneous tissues (i.e., Br~1). SD-OCT images of 83 normal corneas (ages 22-50 years) from a standard SD-OCT device (RTVue-XR Avanti, Optovue Inc.) were processed to establish a normative dataset of transparency values. After confirming stromal homogeneity (Br <10), we measured a median ls of 570 μm (interdecile range: 270-2400 μm). By also considering corneal thicknesses, this may be translated into a median fraction of transmitted (coherent) light Tcoh(stroma) of 51% (interdecile range: 22-83%). Excluding images with central saturation artifact raised our median Tcoh(stroma) to 73% (interdecile range: 34-84%). These transparency values are slightly lower than those previously reported, which we attribute to the detection configuration of SD-OCT with a relatively small and selective acceptance angle. No statistically significant correlation between transparency and age or thickness was found. In conclusion, our algorithm provides robust and quantitative measurements of corneal transparency from standard SD-OCT images with sufficient quality (such as 'Line' and 'CrossLine' B-scan modes without central saturation artifact) and addresses the demand for such an objective means in the clinical setting.
Collapse
Affiliation(s)
- Maëlle Vilbert
- Laboratory for Optics and Biosciences (LOB)— École Polytechnique, CNRS, INSERM, IPP, Palaiseau, France
- Vision Institute—CNRS, INSERM, Sorbonne University, Paris, France
- GRC 32, Transplantation et Thérapies Innovantes de la Cornée, Sorbonne Université, Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts, Paris, France
| | - Romain Bocheux
- Laboratory for Optics and Biosciences (LOB)— École Polytechnique, CNRS, INSERM, IPP, Palaiseau, France
- GRC 32, Transplantation et Thérapies Innovantes de la Cornée, Sorbonne Université, Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts, Paris, France
- Physical Chemistry Institute (ICP)—CNRS, University of Paris-Saclay, Orsay, France
| | - Cristina Georgeon
- GRC 32, Transplantation et Thérapies Innovantes de la Cornée, Sorbonne Université, Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts, Paris, France
| | - Vincent Borderie
- GRC 32, Transplantation et Thérapies Innovantes de la Cornée, Sorbonne Université, Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts, Paris, France
| | - Pascal Pernot
- Physical Chemistry Institute (ICP)—CNRS, University of Paris-Saclay, Orsay, France
| | - Kristina Irsch
- Vision Institute—CNRS, INSERM, Sorbonne University, Paris, France
- GRC 32, Transplantation et Thérapies Innovantes de la Cornée, Sorbonne Université, Centre Hospitalier National d’Ophtalmologie des Quinze-Vingts, Paris, France
| | - Karsten Plamann
- Laboratory for Optics and Biosciences (LOB)— École Polytechnique, CNRS, INSERM, IPP, Palaiseau, France
- LOA—ENSTA Paris, École polytechnique, CNRS, IPP, Palaiseau, France
| |
Collapse
|
4
|
Miażdżyk M, Consejo A, Iskander DR. OCT based corneal densitometry: the confounding effect of epithelial speckle. BIOMEDICAL OPTICS EXPRESS 2023; 14:3871-3880. [PMID: 37799674 PMCID: PMC10549732 DOI: 10.1364/boe.489054] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 06/06/2023] [Accepted: 06/12/2023] [Indexed: 10/07/2023]
Abstract
Corneal densitometry is a clinically validated method for objectively assessing the transparency of stroma. The technique is currently dominated by Scheimpflug technology. Still, optical coherence tomography (OCT), in which examination of the statistical properties of corneal speckle is undertaken, has also been considered to assess corneal densitometry. In-vivo, the stroma is observed via the epithelium. However, the effect of this external layer on stromal densitometry has not been considered as yet. This study aims to quantify the influence of epithelium integrity on corneal OCT densitometry. OCT images from eleven freshly enucleated porcine eyes before and after epithelial debridement were used. OCT densitometry was investigated at different stromal depths using four metrics of speckle statistics. Results indicate that there exist statistically significant differences in speckle statistics for a given stromal depth depending on the presence or absence of the epithelium. The estimation error in speckle statistics can reach over 20% depending on the stromal depth. The anterior stroma densitometry values are the ones most affected by epithelial integrity. In conclusion, if OCT densitometry stromal parameters are to be considered in absolute terms, it is essential to consider the confounding effect of the epithelial layer in the analysis.
Collapse
Affiliation(s)
- Maria Miażdżyk
- Department of Biomedical Engineering,
Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland
| | - Alejandra Consejo
- Department of Applied Physics, University of Zaragoza, Zaragoza, Spain
- Aragon Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
| | - D. Robert Iskander
- Department of Biomedical Engineering,
Wroclaw University of Science and Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland
| |
Collapse
|
5
|
Zhang J, Mazlin V, Fei K, Boccara AC, Yuan J, Xiao P. Time-domain full-field optical coherence tomography (TD-FF-OCT) in ophthalmic imaging. Ther Adv Chronic Dis 2023; 14:20406223231170146. [PMID: 37152350 PMCID: PMC10161339 DOI: 10.1177/20406223231170146] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2022] [Accepted: 03/29/2023] [Indexed: 05/09/2023] Open
Abstract
Ocular imaging plays an irreplaceable role in the evaluation of eye diseases. Developing cellular-resolution ophthalmic imaging technique for more accurate and effective diagnosis and pathogenesis analysis of ocular diseases is a hot topic in the cross-cutting areas of ophthalmology and imaging. Currently, ocular imaging with traditional optical coherence tomography (OCT) is limited in lateral resolution and thus can hardly resolve cellular structures. Conventional OCT technology obtains ultra-high resolution at the expense of a certain imaging range and cannot achieve full field of view imaging. In the early years, Time-domain full-field OCT (TD-FF-OCT) has been mainly used for ex vivo ophthalmic tissue studies, limited by the low speed and low full-well capacity of existing two-dimensional (2D) cameras. The recent improvements in system design opened new imaging possibilities for in vivo applications thanks to its distinctive optical properties of TD-FF-OCT such as a spatial resolution almost insensitive to aberrations, and the possibility to control the curvature of the optical slice. This review also attempts to look at the future directions of TD-FF-OCT evolution, for example, the potential transfer of the functional-imaging dynamic TD-FF-OCT from the ex vivo into in vivo use and its expected benefit in basic and clinical ophthalmic research. Through non-invasive, wide-field, and cellular-resolution imaging, TD-FF-OCT has great potential to be the next-generation imaging modality to improve our understanding of human eye physiology and pathology.
Collapse
Affiliation(s)
- Jinze Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China
| | - Viacheslav Mazlin
- ESPCI Paris, PSL University, CNRS, Langevin Institute, Paris, France
| | - Keyi Fei
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China
| | | | - Jin Yuan
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Jinsui Road 7, Guangzhou 510060, Guangdong, China
| | - Peng Xiao
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Jinsui Road 7, Guangzhou 510060, Guangdong, China
| |
Collapse
|
6
|
Eugui P, Merkle CW, Gesperger J, Lichtenegger A, Baumann B. Investigation of the scattering and attenuation properties of cataracts formed in mouse eyes with 1060-nm and 1310-nm swept-source optical coherence tomography. BIOMEDICAL OPTICS EXPRESS 2021; 12:6391-6406. [PMID: 34745744 PMCID: PMC8547986 DOI: 10.1364/boe.433927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 08/31/2021] [Accepted: 08/31/2021] [Indexed: 06/13/2023]
Abstract
Cataracts are the leading cause of blindness worldwide. Here we propose optical coherence tomography (OCT) as a quantitative method for investigating cataracts. OCT provides volumetric and non-invasive access to the lens and makes it possible to rapidly observe the formation of opacifications in animal models such as mice. We compared the performance of two different wavelengths - 1060 nm and 1310 nm - for OCT imaging in cataract research. In addition, we present multi-contrast OCT capable of mapping depth-resolved scattering and average anterior cortical attenuation properties of the crystalline lens and quantitatively characterize induced cataract development in the mouse eye. Lastly, we also propose a novel method based on the retinal OCT projection image for quantifying and mapping opacifications in the lens, which showed a good correlation with scattering and attenuation characteristics simultaneously analyzed during the process of cataract formation in the lens.
Collapse
Affiliation(s)
- Pablo Eugui
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Conrad W. Merkle
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Johanna Gesperger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
- Division of Neuropathology and Neurochemistry, Department of Neurology, Medical University of Vienna, Austria
| | - Antonia Lichtenegger
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| | - Bernhard Baumann
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Austria
| |
Collapse
|
7
|
Measurement of the Adipose Stem Cells Cell Sheets Transmittance. Bioengineering (Basel) 2021; 8:bioengineering8070093. [PMID: 34356200 PMCID: PMC8301134 DOI: 10.3390/bioengineering8070093] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Revised: 06/26/2021] [Accepted: 06/29/2021] [Indexed: 12/13/2022] Open
Abstract
In the field of cell therapy, the interest in cell sheet technology is increasing. To determine the cell sheet harvesting time requires experience and practice, and different factors could change the harvesting time (variability among donors and culture media, between cell culture dishes, initial cell seeding density). We have developed a device that can measure the transmittance of the multilayer cell sheets, using a light emitting diode and a light detector, to estimate the harvesting time. The transmittance of the adipose stromal cells cell sheets (ASCCS) was measured every other day as soon as the cells were confluent, up to 12 days. The ASCCS, from three different initial seeding densities, were harvested at 8, 10, and 12 days after seeding. Real-time PCR and immunostaining confirmed the expression of specific cell markers (CD29, CD73, CD90, CD105, HLA-A, HLA-DR), but less than the isolated adipose stromal cells. The number of cells per cell sheets, the average thickness per cell sheet, and the corresponding transmittance showed no correlation. Decrease of the transmittance seems to be correlated with the cell sheet maturation. For the first time, we are reporting the success development of a device to estimate ASCCS harvesting time based on their transmittance.
Collapse
|
8
|
Mutoji KN, Sun M, Elliott G, Moreno IY, Hughes C, Gesteira TF, Coulson-Thomas VJ. Extracellular Matrix Deposition and Remodeling after Corneal Alkali Burn in Mice. Int J Mol Sci 2021; 22:5708. [PMID: 34071909 PMCID: PMC8199272 DOI: 10.3390/ijms22115708] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 05/24/2021] [Accepted: 05/25/2021] [Indexed: 12/13/2022] Open
Abstract
Corneal transparency relies on the precise arrangement and orientation of collagen fibrils, made of mostly Type I and V collagen fibrils and proteoglycans (PGs). PGs are essential for correct collagen fibrillogenesis and maintaining corneal homeostasis. We investigated the spatial and temporal distribution of glycosaminoglycans (GAGs) and PGs after a chemical injury. The chemical composition of chondroitin sulfate (CS)/dermatan sulfate (DS) and heparan sulfate (HS) were characterized in mouse corneas 5 and 14 days after alkali burn (AB), and compared to uninjured corneas. The expression profile and corneal distribution of CS/DSPGs and keratan sulfate (KS) PGs were also analyzed. We found a significant overall increase in CS after AB, with an increase in sulfated forms of CS and a decrease in lesser sulfated forms of CS. Expression of the CSPGs biglycan and versican was increased after AB, while decorin expression was decreased. We also found an increase in KS expression 14 days after AB, with an increase in lumican and mimecan expression, and a decrease in keratocan expression. No significant changes in HS composition were noted after AB. Taken together, our study reveals significant changes in the composition of the extracellular matrix following a corneal chemical injury.
Collapse
Affiliation(s)
- Kazadi N. Mutoji
- College of Optometry, University of Houston, Houston, TX 77204, USA; (K.N.M.); (M.S.); (G.E.); (I.Y.M.); (T.F.G.)
| | - Mingxia Sun
- College of Optometry, University of Houston, Houston, TX 77204, USA; (K.N.M.); (M.S.); (G.E.); (I.Y.M.); (T.F.G.)
| | - Garrett Elliott
- College of Optometry, University of Houston, Houston, TX 77204, USA; (K.N.M.); (M.S.); (G.E.); (I.Y.M.); (T.F.G.)
| | - Isabel Y. Moreno
- College of Optometry, University of Houston, Houston, TX 77204, USA; (K.N.M.); (M.S.); (G.E.); (I.Y.M.); (T.F.G.)
| | - Clare Hughes
- School of Biosciences, Cardiff University, Cardiff CF10 3AT, UK;
| | - Tarsis F. Gesteira
- College of Optometry, University of Houston, Houston, TX 77204, USA; (K.N.M.); (M.S.); (G.E.); (I.Y.M.); (T.F.G.)
- Optimvia, Batavia, OH 45103, USA
| | - Vivien J. Coulson-Thomas
- College of Optometry, University of Houston, Houston, TX 77204, USA; (K.N.M.); (M.S.); (G.E.); (I.Y.M.); (T.F.G.)
| |
Collapse
|
9
|
Badon A, Barolle V, Irsch K, Boccara AC, Fink M, Aubry A. Distortion matrix concept for deep optical imaging in scattering media. SCIENCE ADVANCES 2020; 6:eaay7170. [PMID: 32923603 PMCID: PMC7455485 DOI: 10.1126/sciadv.aay7170] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 06/05/2020] [Indexed: 05/03/2023]
Abstract
In optical imaging, light propagation is affected by the inhomogeneities of the medium. Sample-induced aberrations and multiple scattering can strongly degrade the image resolution and contrast. On the basis of a dynamic correction of the incident and/or reflected wavefronts, adaptive optics has been used to compensate for those aberrations. However, it only applies to spatially invariant aberrations or to thin aberrating layers. Here, we propose a global and noninvasive approach based on the distortion matrix concept. This matrix basically connects any focusing point of the image with the distorted part of its wavefront in reflection. A singular value decomposition of the distortion matrix allows to correct for high-order aberrations and forward multiple scattering over multiple isoplanatic modes. Proof-of-concept experiments are performed through biological tissues including a turbid cornea. We demonstrate a Strehl ratio enhancement up to 2500 and recover a diffraction-limited resolution until a depth of 10 scattering mean free paths.
Collapse
Affiliation(s)
- Amaury Badon
- Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 rue Jussieu, 75005 Paris, France
| | - Victor Barolle
- Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 rue Jussieu, 75005 Paris, France
| | - Kristina Irsch
- Vision Institute/Quinze-Vingts National Eye Hospital, Sorbonne University, CNRS UMR 7210, INSERM U 068, 17 rue Moreau, 75012 Paris, France
- The Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - A. Claude Boccara
- Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 rue Jussieu, 75005 Paris, France
| | - Mathias Fink
- Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 rue Jussieu, 75005 Paris, France
| | - Alexandre Aubry
- Institut Langevin, ESPCI Paris, PSL University, CNRS, 1 rue Jussieu, 75005 Paris, France
- Corresponding author.
| |
Collapse
|
10
|
Tricoli U, Carminati R. Modeling of full-field optical coherence tomography in scattering media. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2019; 36:C122-C129. [PMID: 31873707 DOI: 10.1364/josaa.36.00c122] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Accepted: 10/03/2019] [Indexed: 06/10/2023]
Abstract
We develop a model of full-field optical coherence tomography (FF-OCT) that includes a description of partial temporal and spatial coherence, together with a mean-field scattering theory going beyond the Born approximation. Based on explicit expressions of the FF-OCT signal, we discuss essential features of FF-OCT imaging, such as the influence of partial coherence on the optical transfer function, and on the decay of the signal with depth. We derive the conditions under which the spatially averaged signal exhibits a pure exponential decay, providing a clear frame for the use of the Beer-Lambert law for quantitative measurements of the extinction length in scattering media.
Collapse
|