1
|
Wu N, Mao P, Chang N, Zhou Y, Yang W, Fu F, Liu X, Ji T, Zhao J, Huang Y, Li Y, Dickey MD, Gong W. Weavable, Reconfigurable Triboelectric Ferrofluid Fiber for Early Warning. ACS NANO 2024; 18:33319-33329. [PMID: 39611767 DOI: 10.1021/acsnano.4c06225] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2024]
Abstract
As communication technologies have become omnipresent, the prevalence of electromagnetic field (EMF) exposures poses possible health risks, particularly to vulnerable groups such as pregnant women. In response, we introduce a triboelectric ferrofluid fiber (TFF) that moves in response to EMF, thereby generating charge in a way that is self-powered. The TFF is flexible, stretchable (470%), and can be woven into fabrics. The TFF utilizes a soft-contact (ferrofluid-silicon rubber fiber) triboelectric core layer to enhance its sensitivity to EMF, enabling it to detect even minor electromagnetic fluctuations, such as those from cell phone typing. By integrating hydrogel electrodes that offer conductivity and minimal electromagnetic interference shielding, the TFF's sensitivity to magnetic fields is further amplified. Moreover, its open-circuit voltage output is increased by 50% compared to the conventional electrodes. Building on this technology, we designed a smart fabric for environmental early warning and potential real-time pulse monitoring, specifically tailored for the safety and healthcare needs of vulnerable groups. Finally, we developed a sensing and communication apparel (SCA) by integrating TFF into the apparel and exploring its capabilities in a wireless transmission of warning signals and long-distance NFC functionality.
Collapse
Affiliation(s)
- Naiyan Wu
- Anhui Provincial Engineering Center for High Performance Biobased Nylons, Anhui Provincial Engineering Center for Automotive Highly Functional Fiber Products, School of Materials and Chemistry, Anhui Agricultural University, Hefei 230036, China
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
- Department of Electrical and Systems Engineering, Washington University in St. Louis, 1 Brookings Drive, St. Louis, Missouri 63130-4899, United States
| | - Pengxiang Mao
- Anhui Provincial Engineering Center for High Performance Biobased Nylons, Anhui Provincial Engineering Center for Automotive Highly Functional Fiber Products, School of Materials and Chemistry, Anhui Agricultural University, Hefei 230036, China
| | - Ningbo Chang
- Anhui Provincial Engineering Center for High Performance Biobased Nylons, Anhui Provincial Engineering Center for Automotive Highly Functional Fiber Products, School of Materials and Chemistry, Anhui Agricultural University, Hefei 230036, China
| | - Yanrun Zhou
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, St. Louis, Missouri 63130-4899, United States
| | - Weifeng Yang
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Fan Fu
- Anhui Provincial Engineering Center for High Performance Biobased Nylons, Anhui Provincial Engineering Center for Automotive Highly Functional Fiber Products, School of Materials and Chemistry, Anhui Agricultural University, Hefei 230036, China
| | - Xixi Liu
- Anhui Provincial Engineering Center for High Performance Biobased Nylons, Anhui Provincial Engineering Center for Automotive Highly Functional Fiber Products, School of Materials and Chemistry, Anhui Agricultural University, Hefei 230036, China
| | - Tianyi Ji
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Junyi Zhao
- Department of Electrical and Systems Engineering, Washington University in St. Louis, 1 Brookings Drive, St. Louis, Missouri 63130-4899, United States
| | - Yuxuan Huang
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, St. Louis, Missouri 63130-4899, United States
| | - Yaogang Li
- State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China
| | - Michael D Dickey
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Campus Box 7905, Raleigh, North Carolina 27695-7905, United States
| | - Wei Gong
- Anhui Provincial Engineering Center for High Performance Biobased Nylons, Anhui Provincial Engineering Center for Automotive Highly Functional Fiber Products, School of Materials and Chemistry, Anhui Agricultural University, Hefei 230036, China
- Key Laboratory of Agricultural Sensors, Ministry of Agriculture and Rural Affairs, Hefei 230036, China
| |
Collapse
|
2
|
Hoblick S, Denagamage TN, Morton AJ, McCarrel TM. Antimicrobial prophylaxis is not indicated for horses undergoing general anaesthesia for elective orthopaedic MRI. Equine Vet J 2024; 56:475-483. [PMID: 37531950 DOI: 10.1111/evj.13978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 07/18/2023] [Indexed: 08/04/2023]
Abstract
BACKGROUND Post-anaesthetic fever is a known complication of general anaesthesia, however, its incidence in horses undergoing elective magnetic resonance imaging (MRI) is unknown. OBJECTIVE To determine the incidence of post-anaesthetic fever in horses undergoing elective orthopaedic MRI and determine whether prophylactic antimicrobial therapy would be associated with a reduction in the incidence of post-anaesthetic fever. We hypothesised that prophylactic antimicrobials would be associated with a reduction in the incidence of post-anaesthetic fever. STUDY DESIGN Retrospective cross-sectional study. METHODS This retrospective study included 791 elective orthopaedic MRIs in systemically healthy horses between June 2006 and March 2020 that recovered from general anaesthesia and did not undergo surgery or intensive medical therapy soon after recovery. Potential factors associated with post-anaesthetic fever were evaluated using multivariable logistic regression. Case signalment, travel time, preanaesthetic haematology and fibrinogen abnormalities, use of prophylactic antimicrobials, peri-anaesthetic nonsteroidal anti-inflammatories, anaesthesia time and recovery time were all evaluated for association with post-anaesthetic fever. RESULTS Of 791 MRI cases, 44 (5.6%) developed a post-anaesthetic fever. Horses that received prophylactic antimicrobials were [odds ratio (OR) 3.8, 95% confidence interval (CI) 1.98-7.46; p ≤ 0.001] more likely to develop a post-anaesthetic fever than those that did not receive antimicrobials. Young horses (1-4 years of age) were (OR 2.8, 95% CI 1.26-6.17; p = 0.01) more likely to develop fever compared with adult horses (≥5 years of age). MAIN LIMITATIONS Limitations of this study pertain to retrospective analysis including nonrandomised case selection and incomplete data records. CONCLUSIONS While fever may indicate infection, the majority of early post-anaesthetic fevers resolved before discharge from the hospital with no identified cause. The use of prophylactic antimicrobials to reduce the risk of post-anaesthetic fever for elective MRI is not supported by this study.
Collapse
Affiliation(s)
- Sloane Hoblick
- Department of Large Animal Clinical Sciences, University of Florida College of Veterinary Medicine, Gainesville, Florida, USA
| | - Thomas N Denagamage
- Department of Large Animal Clinical Sciences, University of Florida College of Veterinary Medicine, Gainesville, Florida, USA
| | - Alison J Morton
- Department of Large Animal Clinical Sciences, University of Florida College of Veterinary Medicine, Gainesville, Florida, USA
| | - Taralyn M McCarrel
- Department of Large Animal Clinical Sciences, University of Florida College of Veterinary Medicine, Gainesville, Florida, USA
| |
Collapse
|
3
|
Zhao W, Han Y, Shao D, Han C, Tian Y, Huang Q. Effects of ultra-strong static magnetic field on the gut microbiota of humans and mice. Bioelectromagnetics 2023; 44:211-220. [PMID: 37655442 DOI: 10.1002/bem.22482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 06/27/2023] [Accepted: 07/18/2023] [Indexed: 09/02/2023]
Abstract
To explore the effect of ultra-strong static magnetic field on gut microbiota, 16 T static magnetic field was used to study the changes in the structure and composition of human and mouse gut microbiota in this environment. In the mouse gut microbiota, at the genus level, the magnetic field significantly decreased the relative abundances of Escherichia-Shigella, Lactobacillus, Enterococcus, Burkholderia-Caballeronia-Paraburkholderia, Parasutterella, and Ralstonia and significantly increased those of Parabacteroides, Alloprevotella, Alistipes, Odoribacter, Bacteroides, Mucispirillum, Sutterella, and Prevotellaceae_UCG-001. Similarly, at the genus level, the relative abundances of Bacteroides, Parabacteroides, Romboutsia, and Streptococcus significantly decreased in the human gut microbiota. Contrary to the changing trend of the abundance in the mouse gut, the abundances of Bacteroides and Parabacteroides in the human gut were significantly reduced under magnetic field. The BugBase phenotypic prediction analysis showed that the relative abundances of five phenotypes, including anaerobism, mobile elements, potential pathogenicity, stress-tolerant, and biofilm formation, changed significantly in the mouse gut microbiota, while the relative abundances of two phenotypes, including Gram-positive and Gram-negative phenotypes, changed significantly in the human gut microbiota. The 16 T magnetic field could differently affect the composition, structure, and phenotypes of gut microbiota in human and mice, suggesting the importance of model selection in studying the biological effects of magnetic field.
Collapse
Affiliation(s)
- Wen Zhao
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Yijuan Han
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Dongyan Shao
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Cuicui Han
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Yixiao Tian
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Qingsheng Huang
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| |
Collapse
|
4
|
Uzhytchak M, Smolková B, Frtús A, Stupakov A, Lunova M, Scollo F, Hof M, Jurkiewicz P, Sullivan GJ, Dejneka A, Lunov O. Sensitivity of endogenous autofluorescence in HeLa cells to the application of external magnetic fields. Sci Rep 2023; 13:10818. [PMID: 37402779 DOI: 10.1038/s41598-023-38015-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 06/30/2023] [Indexed: 07/06/2023] Open
Abstract
Dramatically increased levels of electromagnetic radiation in the environment have raised concerns over the potential health hazards of electromagnetic fields. Various biological effects of magnetic fields have been proposed. Despite decades of intensive research, the molecular mechanisms procuring cellular responses remain largely unknown. The current literature is conflicting with regards to evidence that magnetic fields affect functionality directly at the cellular level. Therefore, a search for potential direct cellular effects of magnetic fields represents a cornerstone that may propose an explanation for potential health hazards associated with magnetic fields. It has been proposed that autofluorescence of HeLa cells is magnetic field sensitive, relying on single-cell imaging kinetic measurements. Here, we investigate the magnetic field sensitivity of an endogenous autofluorescence in HeLa cells. Under the experimental conditions used, magnetic field sensitivity of an endogenous autofluorescence was not observed in HeLa cells. We present a number of arguments indicating why this is the case in the analysis of magnetic field effects based on the imaging of cellular autofluorescence decay. Our work indicates that new methods are required to elucidate the effects of magnetic fields at the cellular level.
Collapse
Affiliation(s)
- Mariia Uzhytchak
- Department of Optical and Biophysical Systems, Institute of Physics of the Czech Academy of Sciences, Prague, 18221, Czech Republic
| | - Barbora Smolková
- Department of Optical and Biophysical Systems, Institute of Physics of the Czech Academy of Sciences, Prague, 18221, Czech Republic
| | - Adam Frtús
- Department of Optical and Biophysical Systems, Institute of Physics of the Czech Academy of Sciences, Prague, 18221, Czech Republic
| | - Alexandr Stupakov
- Department of Optical and Biophysical Systems, Institute of Physics of the Czech Academy of Sciences, Prague, 18221, Czech Republic
| | - Mariia Lunova
- Department of Optical and Biophysical Systems, Institute of Physics of the Czech Academy of Sciences, Prague, 18221, Czech Republic
- Institute for Clinical and Experimental Medicine (IKEM), Prague, 14021, Czech Republic
| | - Federica Scollo
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, 18223, Czech Republic
| | - Martin Hof
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, 18223, Czech Republic
| | - Piotr Jurkiewicz
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Prague, 18223, Czech Republic
| | - Gareth John Sullivan
- Department of Molecular Medicine, Institute of Basic Medical Sciences, University of Oslo, Oslo, Norway
- Department of Pediatric Research, Oslo University Hospital, Oslo, Norway
- Department of Immunology, Institute of Clinical Medicine, University of Oslo, Oslo, Norway
| | - Alexandr Dejneka
- Department of Optical and Biophysical Systems, Institute of Physics of the Czech Academy of Sciences, Prague, 18221, Czech Republic
| | - Oleg Lunov
- Department of Optical and Biophysical Systems, Institute of Physics of the Czech Academy of Sciences, Prague, 18221, Czech Republic.
| |
Collapse
|
5
|
Otsuka K, Cornelissen G, Weydahl A, Gubin D, Beaty LA, Murase M. Rules of Heliogeomagnetics Diversely Coordinating Biological Rhythms and Promoting Human Health. APPLIED SCIENCES 2023; 13:951. [DOI: 10.3390/app13020951] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/07/2024]
Abstract
This investigation reviews how geomagnetic activity affects the circadian variation in blood pressure (BP) and heart rate (HR) and their variabilities of clinically healthy individuals. A small study in Alta, Norway (latitude of 70.0° N), serves to illustrate the methodology used to outline rules of procedure in exploring heliogeomagnetic effects on human physiology. Volunteers in the Alta study were monitored for at least 2 days between 18 March 2002 and 9 January 2005. Estimates of the circadian characteristics of BP and HR by cosinor and the Maximum Entropy Method (MEM) indicate an increase in the circadian amplitude of systolic (S) BP on geomagnetic-disturbance days compared to quiet days (p = 0.0236). Geomagnetic stimulation was found to be circadian-phase dependent, with stimulation in the evening inducing a 49.2% increase in the circadian amplitude of SBP (p = 0.0003), not observed in relation to stimulation in the morning. In two participants monitored for 7 days, the circadian amplitude of SBP decreased by 23.4% on an extremely disturbed day but increased by 50.3% on moderately disturbed days (p = 0.0044), suggesting a biphasic (hormetic) reaction of the circadian SBP rhythm to geomagnetics. These results indicate a possible role of geomagnetic fluctuations in modulating the circadian system.
Collapse
Affiliation(s)
- Kuniaki Otsuka
- Tokyo Women’s Medical University, Tokyo 162-8666, Japan
- Halberg Chronobiology Center, University of Minnesota, Minneapolis, MN 55455, USA
| | - Germaine Cornelissen
- Halberg Chronobiology Center, University of Minnesota, Minneapolis, MN 55455, USA
| | - Andi Weydahl
- School of Sport Sciences, The Arctic University of Norway, Campus Alta, N-9509 Alta, Norway
| | - Denis Gubin
- Laboratory for Chronobiology and Chronomedicine, Research Institute of Biomedicine and Biomedical Technologies, Medical University, 625023 Tyumen, Russia
- Department of Biology, Medical University, 625023 Tyumen, Russia
- Tyumen Cardiology Research Center, Tomsk National Research Medical Center, Russian Academy of Science, 634009 Tomsk, Russia
| | - Larry A. Beaty
- Halberg Chronobiology Center, University of Minnesota, Minneapolis, MN 55455, USA
| | - Masatoshi Murase
- Yukawa Institute for Theoretical Physics, Kyoto University, Kyoto 606-8502, Japan
| |
Collapse
|
6
|
Inuzuka S. Oriented Magnetic Fields and Blood Pressure. INTERNATIONAL JOURNAL OF CARDIOVASCULAR SCIENCES 2022. [DOI: 10.36660/ijcs.20220167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
7
|
Makinistian L, Zastko L, Tvarožná A, Días LE, Belyaev I. Static magnetic fields from earphones: Detailed measurements plus some open questions. ENVIRONMENTAL RESEARCH 2022; 214:113907. [PMID: 35870506 DOI: 10.1016/j.envres.2022.113907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 06/09/2022] [Accepted: 07/11/2022] [Indexed: 06/15/2023]
Abstract
Earphones (EP) are a worldwide, massively adopted product, assumed to be innocuous provided the recommendations on sound doses limits are followed. Nevertheless, sound is not the only physical stimulus that derives from EP use, since they include a built-in permanent magnet from which a static magnetic field (SMF) originates. We performed 2D maps of the SMF at several distances from 6 models of in-ear EP, showing that they produce an exposure that spans from ca. 20 mT on their surface down to tens of μT in the inner ear. The numerous reports of bioeffects elicited by SMF in that range of intensities (applied both acutely and chronically), together with the fact that there is no scientific consensus over the possible mechanisms of interaction with living tissues, suggest that caution could be recommendable. In addition, more research is warranted on the possible effects of the combination of SMF with extremely low frequency and radiofrequency fields, which has so far been scarcely studied. Overall, while several open questions about bioeffects of SMF remain to be addressed by the scientific community, we find sensible to suggest that the use of air-tube earphones is probably the more conservative, cautious choice.
Collapse
Affiliation(s)
- L Makinistian
- Department of Physics, Universidad Nacional de San Luis (UNSL), San Luis, Argentina; Instituto de Física Aplicada (INFAP), Universidad Nacional de San Luis (UNSL)-CONICET, San Luis, Argentina.
| | - L Zastko
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Center, University Science Park for Biomedicine, Slovak Academy of Sciences, Bratislava, Slovakia; Department of Laboratory Medicine, Faculty of Health Care, Catholic University in Ružomberok, Ružomberok, Slovakia
| | - A Tvarožná
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Center, University Science Park for Biomedicine, Slovak Academy of Sciences, Bratislava, Slovakia
| | - L E Días
- Department of Physics, Universidad Nacional de San Luis (UNSL), San Luis, Argentina
| | - I Belyaev
- Department of Radiobiology, Cancer Research Institute, Biomedical Research Center, University Science Park for Biomedicine, Slovak Academy of Sciences, Bratislava, Slovakia
| |
Collapse
|
8
|
Occupational Exposure Assessment of the Static Magnetic Field Generated by Nuclear Magnetic Resonance Spectroscopy: A Case Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19137674. [PMID: 35805332 PMCID: PMC9265854 DOI: 10.3390/ijerph19137674] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 06/09/2022] [Accepted: 06/21/2022] [Indexed: 01/27/2023]
Abstract
Magnetic resonance (MR) systems are used in academic research laboratories and industrial research fields, besides representing one of the most important imaging modalities in clinical radiology. This technology does not use ionizing radiation, but it cannot be considered without risks. These risks are associated with the working principle of the technique, which mainly involves static magnetic fields that continuously increase—namely, the radiofrequency (RF) field and spatial magnetic field gradient. To prevent electromagnetic hazards, the EU and ICNIRP have defined workers’ exposure limits. Several studies that assess health risks for workers and patients of diagnostic MR are reported in the literature, but data on workers’ risk evaluation using nuclear MR (NMR) spectroscopy are very poor. Therefore, the aim of this research is the risk assessment of an NMR environment, paying particular attention to workers with active implantable medical devices (AIMDs). Our perspective study consisted of the measurement of the static magnetic field around a 300 MHz (7 T) NMR research spectrometer and the computation of the electric field induced by the movements of an operator. None of the calculated exposure parameters exceeded the threshold limits imposed by legislation for protection against short-term effects of acute occupational exposure, but our results revealed that the level of exposure exceeded the action level threshold limit for workers with AIMD during the execution of tasks requiring the closest proximity to the spectrometer. Moreover, the strong dependence of the induced electric field results from the walking speed models is shown. This case study represents a snapshot of the NMR risk assessment with the specific goal to increase the interest in the safety of NMR environments.
Collapse
|
9
|
Bodewein L, Dechent D, Graefrath D, Kraus T, Krause T, Driessen S. Systematic review of the physiological and health-related effects of radiofrequency electromagnetic field exposure from wireless communication devices on children and adolescents in experimental and epidemiological human studies. PLoS One 2022; 17:e0268641. [PMID: 35648738 PMCID: PMC9159629 DOI: 10.1371/journal.pone.0268641] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Accepted: 04/29/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND For more than 20 years, the potential health risks of radiofrequency electromagnetic field (RF EMF) exposure from mobile communication devices on children and adolescents have been examined because they are considered sensitive population groups; however, it remains unclear whether such exposure poses any particular risk to them. OBJECTIVES The aim of this review was to systematically analyze and evaluate the physiological and health-related effects of RF EMF exposures from wireless communication devices (mobile phones, cordless phones, Bluetooth, etc.) on children and adolescents. METHODS This review was prepared according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Methodological limitations in individual studies were assessed using the Office of Health Assessment and Translation (OHAT) Risk-of-Bias Rating Tool for Human and Animal Studies. RESULTS A total of 42 epidemiological and 11 experimental studies were eligible for this review. Most of the studies displayed several methodological weaknesses that limited the internal validity of the results. Due to a lack of consistency regarding the outcomes as well as the lack of scientific rigor in most reviewed studies, the body of evidence for the effects of RF EMF of mobile communication devices on subjective symptoms, cognition, and behavior in children and adolescents was low to inadequate. Evidence from the studies investigating early childhood development, brain activity, cancer, and physiological parameters was considered inadequate for drawing conclusions about possible effects. DISCUSSION Overall, the body of evidence allows no final conclusion on the question whether exposure to RF EMF from mobile communication devices poses a particular risk to children and adolescents. There has been rapid development in technologies generating RF EMF, which are extensively used by children and adolescents. Therefore, we strongly recommend high-quality systematic research on children and adolescents, since they are generally considered as sensitive age groups.
Collapse
Affiliation(s)
- Lambert Bodewein
- Research Center for Bioelectromagnetic Interaction (femu)–Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Dagmar Dechent
- Research Center for Bioelectromagnetic Interaction (femu)–Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - David Graefrath
- Research Center for Bioelectromagnetic Interaction (femu)–Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Thomas Kraus
- Research Center for Bioelectromagnetic Interaction (femu)–Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Tobias Krause
- Research Center for Bioelectromagnetic Interaction (femu)–Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Sarah Driessen
- Research Center for Bioelectromagnetic Interaction (femu)–Institute for Occupational, Social and Environmental Medicine, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
10
|
Guleken Z, Kula-Maximenko M, Depciuch J, Kılıç AM, Sarıbal D. Detection of the chemical changes in blood, liver, and brain caused by electromagnetic field exposure using Raman spectroscopy, biochemical assays combined with multivariate analyses. Photodiagnosis Photodyn Ther 2022; 38:102779. [DOI: 10.1016/j.pdpdt.2022.102779] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2022] [Revised: 02/16/2022] [Accepted: 02/17/2022] [Indexed: 12/20/2022]
|
11
|
An Open Question: Is Non-Ionizing Radiation a Tool for Controlling Apoptosis-Induced Proliferation? Int J Mol Sci 2021; 22:ijms222011159. [PMID: 34681819 PMCID: PMC8537877 DOI: 10.3390/ijms222011159] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 10/08/2021] [Indexed: 12/24/2022] Open
Abstract
Non-ionizing radiation is commonly used in the clinical setting, despite its known ability to trigger oxidative stress and apoptosis, which can lead to damage and cell death. Although induction of cell death is typically considered harmful, apoptosis can also be beneficial in the right context. For example, cell death can serve as the signal for new tissue growth, such as in apoptosis-induced proliferation. Recent data has shown that exposure to non-ionizing radiation (such as weak static magnetic fields, weak radiofrequency magnetic fields, and weak electromagnetic fields) is able to modulate proliferation, both in cell culture and in living organisms (for example during tissue regeneration). This occurs via in vivo changes in the levels of reactive oxygen species (ROS), which are canonical activators of apoptosis. This review will describe the literature that highlights the tantalizing possibility that non-ionizing radiation could be used to manipulate apoptosis-induced proliferation to either promote growth (for regenerative medicine) or inhibit it (for cancer therapies). However, as uncontrolled growth can lead to tumorigenesis, much more research into this exciting and developing area is needed in order to realize its promise.
Collapse
|
12
|
Vijayalaxmi, Foster KR. Improving the Quality of Radiofrequency Bioeffects Research: The Need for a Carrot and a Stick. Radiat Res 2021; 196:417-422. [PMID: 34270779 DOI: 10.1667/rade-21-00079.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2021] [Accepted: 06/21/2021] [Indexed: 11/03/2022]
Abstract
This commentary considers research needs for radiofrequency (RF) energy above 6 GHz, including in the "high band" of 5G New Radio (NR) communications systems that exists just beneath the mm-wave band (30-300 GHz). As of late 2020, approximately 100 RF bioeffects studies have been published involving exposures above 6 GHz, encompassing a wide range of exposure levels and frequencies. A majority of these studies report statistically significant effects of exposure, many at exposures within international safety limits. This commentary examines 31 genetic damage studies involving RF exposures above 6 GHz in the context of two sets of quality-assessment criteria: 1. "Risk of bias" (RoB) criteria used for systematic reviews of health-related studies; and 2. a broader set of criteria for research quality from a different scholarly approach (metascience). The 31 studies report several statistically significant effects of exposure on different markers for genetic damage. These effects, if real, would have great potential significance for carcinogen risk assessment. However, the studies as a group have significant technical weaknesses, including small size, failure to meet multiple RoB criteria, naïve use of statistics, and lack of prespecified hypotheses and methods of analysis, all of which increase the chances of false discovery. Here we propose a "carrot" (adequate funding to support high-quality research) and a "stick" (more stringent review of bioeffects manuscripts, including explicit instructions to reviewers to assess study quality) approach to increase the reliability of RF bioeffects studies to facilitate health agency reviews of this socially controversial topic.
Collapse
Affiliation(s)
- Vijayalaxmi
- Department of Radiology, University of Texas Health Science Center, San Antonio, Texas 78229
| | - Kenneth R Foster
- Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19106
| |
Collapse
|
13
|
Exploration of the Supraspinal Hypotheses about Spinal Cord Stimulation and Dorsal Root Ganglion Stimulation: A Systematic Review. J Clin Med 2021; 10:jcm10132766. [PMID: 34201877 PMCID: PMC8268298 DOI: 10.3390/jcm10132766] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Revised: 06/19/2021] [Accepted: 06/20/2021] [Indexed: 12/27/2022] Open
Abstract
Despite the established efficacy and effectiveness of Spinal Cord Stimulation (SCS), there is still no consensus on the supraspinal mechanisms of action of this therapy. The purpose of this study was to systematically review previously raised hypotheses concerning supraspinal mechanisms of action of SCS based on human, animal and computational studies. Searches were conducted using four electronic databases (PubMed, EMBASE, SCOPUS and Web of Science), backward reference searching and consultation with experts. The study protocol was registered prior to initiation of the review process (PROSPERO CRD42020161531). A total of 54 publications were included, 21 of which were animal studies, and 33 were human studies. The supraspinal hypotheses (n = 69) identified from the included studies could be categorized into six groups concerning the proposed supraspinal hypothesis, namely descending pathways (n = 24); ascending medial pathway (n = 13); ascending lateral pathway (n = 10); affective/motivational influences (n = 8); spinal–cerebral (thalamic)-loop (n = 3) and miscellaneous (n = 11). Scientific support is provided for the hypotheses identified. Modulation of the descending nociceptive inhibitory pathways, medial and lateral pathways were the most frequently reported hypotheses about the supraspinal mechanisms of action of SCS. These hypotheses were mainly supported by studies with a high or moderate confidence in the body of evidence.
Collapse
|