1
|
Dias M, Gomes B, Pena P, Cervantes R, Beswick A, Duchaine C, Kolk A, Madsen AM, Oppliger A, Pogner C, Duquenne P, Wouters IM, Crook B, Viegas C. Filling the knowledge gap: Scoping review regarding sampling methods, assays, and further requirements to assess airborne viruses. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 946:174016. [PMID: 38908595 DOI: 10.1016/j.scitotenv.2024.174016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 06/12/2024] [Accepted: 06/13/2024] [Indexed: 06/24/2024]
Abstract
Assessment of occupational exposure to viruses is crucial to identify virus reservoirs and sources of dissemination at an early stage and to help prevent spread between employees and to the general population. Measuring workers' exposure can facilitate assessment of the effectiveness of protective and mitigation measures in place. The aim of this scoping review is to give an overview of available methods and those already implemented for airborne virus' exposure assessment in different occupational and indoor environments. The results retrieved from the different studies may contribute to the setting of future standards and guidelines to ensure a reliable risk characterization in the occupational environments crucial for the implementation of effective control measures. The search aimed at selecting studies between January 1st 2010 and June 30th 2023 in the selected databases. Fifty papers on virus exposure assessment fitted the eligibility criteria and were selected for data extraction. Overall, this study identified gaps in knowledge regarding virus assessment and pinpointed the needs for further research. Several discrepancies were found (transport temperatures, elution steps, …), as well as a lack of publication of important data related to the exposure conditions (contextual information). With the available information, it is impossible to compare results between studies employing different methods, and even if the same methods are used, different conclusions/recommendations based on the expert judgment have been reported due to the lack of consensus in the contextual information retrieved and/or data interpretation. Future research on the field targeting sampling methods and in the laboratory regarding the assays to employ should be developed bearing in mind the different goals of the assessment.
Collapse
Affiliation(s)
- Marta Dias
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal
| | - Bianca Gomes
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; CE3C-Center for Ecology, Evolution and Environmental Change, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisbon, Portugal
| | - Pedro Pena
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal
| | - Renata Cervantes
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal
| | - Alan Beswick
- Health and Safety Executive Science and Research Centre, Buxton SK17 9JN, UK
| | - Caroline Duchaine
- Département de biochimie, microbiologie et bio-informatique, Université Laval, Québec, Canada
| | - Annette Kolk
- Institute for Occupational Safety and Health of the German Social Accident Insurance, Alte Heerstraße 111, 53757 Sankt Augustin, Germany
| | - Anne Mette Madsen
- National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark
| | | | | | | | - Inge M Wouters
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Utrecht, the Netherlands
| | - Brian Crook
- Health and Safety Executive Science and Research Centre, Buxton SK17 9JN, UK
| | - Carla Viegas
- H&TRC - Health & Technology Research Center, ESTeSL - Escola Superior de Tecnologia e Saúde, Instituto Politécnico de Lisboa, Portugal; NOVA National School of Public Health, Public Health Research Centre, Comprehensive Health Research Center, CHRC, REAL, CCAL, NOVA University Lisbon, Lisbon, Portugal.
| |
Collapse
|
2
|
Bøifot KO, Skogan G, Dybwad M. Sampling efficiency and nucleic acid stability during long-term sampling with different bioaerosol samplers. ENVIRONMENTAL MONITORING AND ASSESSMENT 2024; 196:577. [PMID: 38795190 PMCID: PMC11127824 DOI: 10.1007/s10661-024-12735-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Accepted: 05/17/2024] [Indexed: 05/27/2024]
Abstract
Aerosol microbiome studies have received increased attention as technological advancements have made it possible to dive deeper into the microbial diversity. To enhance biomass collection for metagenomic sequencing, long-term sampling is a common strategy. While the impact of prolonged sampling times on microorganisms' culturability and viability is well-established, its effect on nucleic acid stability remains less understood but is essential to ensure representative sample collection. This study evaluated four air samplers (SKC BioSampler, SASS3100, Coriolis μ, BioSpot-VIVAS 300-P) against a reference sampler (isopore membrane filters) to identify nucleic acid stability during long-term sampling. Physical sampling efficiencies determined with a fluorescent tracer for three particle sizes (0.8, 1, and 3 μm), revealed high efficiencies (> 80% relative to reference) for BioSampler, SASS3100, and BioSpot-VIVAS for all particle sizes, and for Coriolis with 3 μm particles. Coriolis exhibited lower efficiency for 0.8 μm (7%) and 1 μm (50%) particles. During 2-h sampling with MS2 and Pantoea agglomerans, liquid-based collection with Coriolis and BioSampler showed a decrease in nucleic acid yields for all test conditions. BioSpot-VIVAS displayed reduced sampling efficiency for P. agglomerans compared to MS2 and the other air samplers, while filter-based collection with SASS3100 and isopore membrane filters, showed indications of DNA degradation for 1 μm particles of P. agglomerans after long-term sampling. These findings show that long-term air sampling affects nucleic acid stability in both liquid- and filter-based collection methods. These results highlight bias produced by bioaerosol collection and should be considered when selecting an air sampler and interpreting aerosol microbiome data.
Collapse
Affiliation(s)
- Kari Oline Bøifot
- Norwegian Defence Research Establishment, P.O. Box 25, NO-2027, Kjeller, Norway.
- Department of Analytical, Environmental and Forensic Sciences, King's College London, 150 Stamford Street, London, SE1 9NH, UK.
| | - Gunnar Skogan
- Norwegian Defence Research Establishment, P.O. Box 25, NO-2027, Kjeller, Norway
| | - Marius Dybwad
- Norwegian Defence Research Establishment, P.O. Box 25, NO-2027, Kjeller, Norway
- Department of Analytical, Environmental and Forensic Sciences, King's College London, 150 Stamford Street, London, SE1 9NH, UK
| |
Collapse
|
3
|
Gaetano AS, Semeraro S, Greco S, Greco E, Cain A, Perrone MG, Pallavicini A, Licen S, Fornasaro S, Barbieri P. Bioaerosol Sampling Devices and Pretreatment for Bacterial Characterization: Theoretical Differences and a Field Experience in a Wastewater Treatment Plant. Microorganisms 2024; 12:965. [PMID: 38792794 PMCID: PMC11124041 DOI: 10.3390/microorganisms12050965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2024] [Revised: 05/06/2024] [Accepted: 05/08/2024] [Indexed: 05/26/2024] Open
Abstract
Studies on bioaerosol bacterial biodiversity have relevance in both ecological and health contexts, and molecular methods, such as 16S rRNA gene-based barcoded sequencing, provide efficient tools for the analysis of airborne bacterial communities. Standardized methods for sampling and analysis of bioaerosol DNA are lacking, thus hampering the comparison of results from studies implementing different devices and procedures. Three samplers that use gelatin filtration, swirling aerosol collection, and condensation growth tubes for collecting bioaerosol at an aeration tank of a wastewater treatment plant in Trieste (Italy) were used to determine the bacterial biodiversity. Wastewater samples were collected directly from the untreated sewage to obtain a true representation of the microbiological community present in the plant. Different samplers and collection media provide an indication of the different grades of biodiversity, with condensation growth tubes and DNA/RNA shieldTM capturing the richer bacterial genera. Overall, in terms of relative abundance, the air samples have a lower number of bacterial genera (64 OTUs) than the wastewater ones (75 OTUs). Using the metabarcoding approach to aerosol samples, we provide the first preliminary step toward the understanding of a significant diversity between different air sampling systems, enabling the scientific community to orient research towards the most informative sampling strategy.
Collapse
Affiliation(s)
- Anastasia Serena Gaetano
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri, 1, 34127 Trieste, Italy; (A.S.G.); (S.S.); (E.G.); (S.L.); (S.F.)
- INSTM National Interuniversity Consortium of Materials Science and Technology, Via G. Giusti, 9, 50121 Firenze, Italy
| | - Sabrina Semeraro
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri, 1, 34127 Trieste, Italy; (A.S.G.); (S.S.); (E.G.); (S.L.); (S.F.)
- INSTM National Interuniversity Consortium of Materials Science and Technology, Via G. Giusti, 9, 50121 Firenze, Italy
| | - Samuele Greco
- Department of Life Sciences, University of Trieste, Via L. Giorgieri, 5, 34127 Trieste, Italy;
| | - Enrico Greco
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri, 1, 34127 Trieste, Italy; (A.S.G.); (S.S.); (E.G.); (S.L.); (S.F.)
- INSTM National Interuniversity Consortium of Materials Science and Technology, Via G. Giusti, 9, 50121 Firenze, Italy
| | - Andrea Cain
- ACEGAS APS AMGA S.p.a., Via degli Alti Forni, 11, 34121 Trieste, Italy;
| | | | - Alberto Pallavicini
- Department of Life Sciences, University of Trieste, Via L. Giorgieri, 5, 34127 Trieste, Italy;
| | - Sabina Licen
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri, 1, 34127 Trieste, Italy; (A.S.G.); (S.S.); (E.G.); (S.L.); (S.F.)
| | - Stefano Fornasaro
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri, 1, 34127 Trieste, Italy; (A.S.G.); (S.S.); (E.G.); (S.L.); (S.F.)
| | - Pierluigi Barbieri
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri, 1, 34127 Trieste, Italy; (A.S.G.); (S.S.); (E.G.); (S.L.); (S.F.)
- INSTM National Interuniversity Consortium of Materials Science and Technology, Via G. Giusti, 9, 50121 Firenze, Italy
| |
Collapse
|
4
|
Tian Y, Dong L. On-The-Spot Sampling and Detection of Viral Particles on Solid Surfaces Using a Sponge Virus Sensor Incorporated with Finger-Press Fluid Release. ACS Sens 2024; 9:1978-1991. [PMID: 38564767 DOI: 10.1021/acssensors.3c02766] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024]
Abstract
This paper presents a sponge-based electrochemical sensor for rapid, on-site collection and analysis of infectious viruses on solid surfaces. The device utilizes a conducting porous sponge modified with graphene, graphene oxide, and specific antibodies. The sponge serves as a hydrophilic porous electrode capable of liquid collection and electrochemical measurements. The device operation involves spraying an aqueous solution on a target surface, swiping the misted surface using the sponge, discharging an electrolyte solution with a simple finger press, and performing in situ incubation and electrochemical measurements. By leveraging the water-absorbing ability of the biofunctionalized conducting sponge, the sensor can effectively collect and quantify virus particles from the surface. The portability of the device is enhanced by introducing a push-release feature that dispenses the liquid electrolyte from a miniature reservoir onto the sensor surface. This reservoir has sharp edges to rupture a liquid sealing film with a finger press. The ability of the device to sample and quantify viral particles is demonstrated by using influenza A virus as the model. The sensor provided a calculated limit of detection of 0.4 TCID50/mL for H1N1 virus, along with a practical concentration range from 1-106 TCID50/mL. Additionally, it achieves a 15% collection efficiency from single-run swiping on a tabletop surface. This versatile device allows for convenient on-site virus detection within minutes, eliminating the need for sample pretreatment and simplifying the entire sample collecting and measuring process. This device presents significant potential for rapid virus detection on solid surfaces.
Collapse
Affiliation(s)
- Yang Tian
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, United States
| | - Liang Dong
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, United States
- Microelectronics Research Center, Iowa State University, Ames, Iowa 50011, United States
| |
Collapse
|
5
|
Vass WB, Shankar SN, Lednicky JA, Yang Y, Manzanas C, Zhang Y, Boyette J, Chen J, Chen Y, Shirkhani A, Washeem M, Fan ZH, Eiguren-Fernandez A, Jutla A, Wu CY. Detection and isolation of infectious SARS-CoV-2 omicron subvariants collected from residential settings. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2023; 57:1142-1153. [PMID: 38143528 PMCID: PMC10735208 DOI: 10.1080/02786826.2023.2251537] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Accepted: 08/17/2023] [Indexed: 12/26/2023]
Abstract
Airborne transmission of infectious (viable) SARS-CoV-2 is increasingly accepted as the primary manner by which the virus is spread from person to person. Risk of exposure to airborne virus is higher in enclosed and poorly ventilated spaces. We present a study focused on air sampling within residences occupied by individuals with COVID-19. Air samplers (BioSpot-VIVAS, VIVAS, and BC-251) were positioned in primary- and secondary-occupancy regions in seven homes. Swab samples were collected from high-touch surfaces. Isolation of SARS-CoV-2 was attempted for samples with virus detectable by RT-qPCR. Viable virus was quantified by plaque assay, and complete virus genome sequences were obtained for selected samples from each sampling day. SARS-CoV-2 was detected in 24 of 125 samples (19.2%) by RT-qPCR and isolated from 14 (11.2%) in cell cultures. It was detected in 80.9% (17/21) and cultured from 61.9% (13/21) of air samples collected using water condensation samplers, compared to swab samples which had a RT-qPCR detection rate of 10.5% (4/38) and virus isolation rate of 2.63% (1/38). No statistically significant differences existed in the likelihood of virus detection by RT-qPCR or amount of infectious virus in the air between areas of primary and secondary occupancy within residences. Our work provides information about the presence of SARS-CoV-2 in the air within homes of individuals with COVID-19. Information herein can help individuals make informed decisions about personal exposure risks when sharing indoor spaces with infected individuals isolating at home and further inform health departments and the public about SARS-CoV-2 exposure risks within residences.
Collapse
Affiliation(s)
- William B. Vass
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Sripriya Nannu Shankar
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - John A. Lednicky
- Department of Environmental and Global Health, University of Florida, Gainesville, Florida, USA
- Emerging Pathogens Institute, University of Florida, Gainesville, Florida, USA
| | - Yang Yang
- Department of Statistics, University of Georgia, Athens, Georgia, USA
| | - Carlos Manzanas
- Department of Mechanical & Aerospace Engineering, University of Florida, Gainesville, Florida, USA
| | - Yuetong Zhang
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Jessica Boyette
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Jiayi Chen
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Yuqiao Chen
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Amin Shirkhani
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Mo Washeem
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Z. Hugh Fan
- Department of Mechanical & Aerospace Engineering, University of Florida, Gainesville, Florida, USA
- Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida, USA
| | | | - Antarpreet Jutla
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
| | - Chang-Yu Wu
- Department of Environmental Engineering Sciences, University of Florida, Gainesville, Florida, USA
- Department of Chemical, Environmental, and Materials Engineering, University of Miami, Coral Gables, Florida, USA
| |
Collapse
|
6
|
Puthussery JV, Ghumra DP, McBrearty KR, Doherty BM, Sumlin BJ, Sarabandi A, Mandal AG, Shetty NJ, Gardiner WD, Magrecki JP, Brody DL, Esparza TJ, Bricker TL, Boon ACM, Yuede CM, Cirrito JR, Chakrabarty RK. Real-time environmental surveillance of SARS-CoV-2 aerosols. Nat Commun 2023; 14:3692. [PMID: 37429842 DOI: 10.1038/s41467-023-39419-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 06/12/2023] [Indexed: 07/12/2023] Open
Abstract
Real-time surveillance of airborne SARS-CoV-2 virus is a technological gap that has eluded the scientific community since the beginning of the COVID-19 pandemic. Offline air sampling techniques for SARS-CoV-2 detection suffer from longer turnaround times and require skilled labor. Here, we present a proof-of-concept pathogen Air Quality (pAQ) monitor for real-time (5 min time resolution) direct detection of SARS-CoV-2 aerosols. The system synergistically integrates a high flow (~1000 lpm) wet cyclone air sampler and a nanobody-based ultrasensitive micro-immunoelectrode biosensor. The wet cyclone showed comparable or better virus sampling performance than commercially available samplers. Laboratory experiments demonstrate a device sensitivity of 77-83% and a limit of detection of 7-35 viral RNA copies/m3 of air. Our pAQ monitor is suited for point-of-need surveillance of SARS-CoV-2 variants in indoor environments and can be adapted for multiplexed detection of other respiratory pathogens of interest. Widespread adoption of such technology could assist public health officials with implementing rapid disease control measures.
Collapse
Affiliation(s)
- Joseph V Puthussery
- Center for Aerosol Science and Engineering, Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Dishit P Ghumra
- Center for Aerosol Science and Engineering, Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Kevin R McBrearty
- Department of Neurology, Hope Center for Neurological Disease, Knight Alzheimer's Disease Research Center, Washington University, St. Louis, MO, 63110, USA
| | - Brookelyn M Doherty
- Department of Neurology, Hope Center for Neurological Disease, Knight Alzheimer's Disease Research Center, Washington University, St. Louis, MO, 63110, USA
| | - Benjamin J Sumlin
- Center for Aerosol Science and Engineering, Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Amirhossein Sarabandi
- Center for Aerosol Science and Engineering, Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
| | - Anushka Garg Mandal
- Center for Aerosol Science and Engineering, Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
- Department of Chemical Engineering, Indian Institute of Technology Bombay, Mumbai, 400076, India
| | - Nishit J Shetty
- Center for Aerosol Science and Engineering, Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA
- Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, 24061, USA
| | - Woodrow D Gardiner
- Department of Neurology, Hope Center for Neurological Disease, Knight Alzheimer's Disease Research Center, Washington University, St. Louis, MO, 63110, USA
| | - Jordan P Magrecki
- Department of Neurology, Hope Center for Neurological Disease, Knight Alzheimer's Disease Research Center, Washington University, St. Louis, MO, 63110, USA
| | - David L Brody
- National Institute of Neurological Disorders and Stroke, Bethesda, MD, USA
- Department of Neurology, Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| | - Thomas J Esparza
- National Institute of Neurological Disorders and Stroke, Bethesda, MD, USA
| | - Traci L Bricker
- Department of Medicine, Washington University, St. Louis, MO, 63110, USA
| | - Adrianus C M Boon
- Department of Medicine, Washington University, St. Louis, MO, 63110, USA
- Departments Molecular Microbiology, and Pathology and Immunology, Washington University School of Medicine, St. Louis, MO, USA
| | - Carla M Yuede
- Department of Psychiatry, Washington University School of Medicine, St. Louis, MO, 63110, USA.
| | - John R Cirrito
- Department of Neurology, Hope Center for Neurological Disease, Knight Alzheimer's Disease Research Center, Washington University, St. Louis, MO, 63110, USA.
| | - Rajan K Chakrabarty
- Center for Aerosol Science and Engineering, Department of Energy, Environmental and Chemical Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA.
| |
Collapse
|
7
|
Mielke SR, Lendzele S, Delgado AH, Abdoulmoumini M, Dickmu S, Garabed R. Patterns of foot-and-mouth disease virus detection in environmental samples in an endemic setting. Front Vet Sci 2023; 10:1157538. [PMID: 37396995 PMCID: PMC10312077 DOI: 10.3389/fvets.2023.1157538] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 05/29/2023] [Indexed: 07/04/2023] Open
Abstract
Foot-and-Mouth Disease virus (FMDV) is endemic in several regions and is a virus that can persist in the environment dependent on pH, relative humidity (RH), temperature, and matrix (i.e., soil, water, or air). Our previously published analysis of available viral persistence data showed that persistence is likely affected by interactions between RH, temperature, and matrix. Understanding these relationships will aid efforts to eliminate FMD, which has significant impacts on economies and food security. In Cameroon, West Africa, the livestock system consists of mobile (transhumant), transboundary trade and sedentary herds. Studying this system can provide information about the patterns of environmental detection of FMDV RNA that may influence approaches to virus elimination on premises during an outbreak. To improve our understanding of these patterns, we collected samples from individuals, vehicles, and along cattle pathways at three sedentary herds beginning on day one of owner-reported outbreaks, ending by day 30, and tested for the presence of FMD viral RNA using rRT-PCR. Our analysis suggests that detection decreases in soil surface samples with increased distance from herd and time from the first report of disease. Whereas time but not distance decreases detection in air samples. Interaction of RH and temperature suggests increased detection at high temperatures (>24°C) and RH (>75%), providing us with new information about the patterns of FMD viral RNA detection in and around cattle herds that could help to inform targeted virus elimination strategies, such as location and application of disinfectants.
Collapse
Affiliation(s)
- Sarah R. Mielke
- Department of Veterinary Preventive Medicine, The Ohio State University College of Veterinary Medicine, Columbus, OH, United States
- United States Department of Agriculture’s Animal and Plant Health Inspection Service (APHIS), Fort Collins, CO, United States
| | - Sevidzem Lendzele
- Transmissible Diseases Ecology Laboratory, Department of Environmental Health, Faculty of Technology and Health Management, Université Libreville Nord, Libreville, Gabon
| | - Amy H. Delgado
- United States Department of Agriculture’s Animal and Plant Health Inspection Service (APHIS), Fort Collins, CO, United States
| | - Mamoudou Abdoulmoumini
- School of Veterinary Science and Medicine, University of Ngaoundéré, Ngaoundéré, Adamawa, Cameroon
| | - Simon Dickmu
- The National Veterinary Laboratory (LANAVET), Garoua North, Cameroon
- University of Bamenda, Bambili, Cameroon
| | - Rebecca Garabed
- Department of Veterinary Preventive Medicine, The Ohio State University College of Veterinary Medicine, Columbus, OH, United States
| |
Collapse
|
8
|
James J, Warren CJ, De Silva D, Lewis T, Grace K, Reid SM, Falchieri M, Brown IH, Banyard AC. The Role of Airborne Particles in the Epidemiology of Clade 2.3.4.4b H5N1 High Pathogenicity Avian Influenza Virus in Commercial Poultry Production Units. Viruses 2023; 15:1002. [PMID: 37112981 PMCID: PMC10142477 DOI: 10.3390/v15041002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 04/11/2023] [Accepted: 04/15/2023] [Indexed: 04/29/2023] Open
Abstract
Since October 2021, Europe has experienced the largest avian influenza virus (AIV) epizootic, caused by clade 2.3.4.4b H5N1 high pathogenicity AIV (HPAIV), with over 284 poultry infected premises (IPs) and 2480 dead H5N1-positive wild birds detected in Great Britain alone. Many IPs have presented as geographical clusters, raising questions about the lateral spread between premises by airborne particles. Airborne transmission over short distances has been observed for some AIV strains. However, the risk of airborne spread of this strain remains to be elucidated. We conducted extensive sampling from IPs where clade 2.3.4.4b H5N1 HPAIVs were confirmed during the 2022/23 epizootic, each representing a major poultry species (ducks, turkeys, and chickens). A range of environmental samples were collected inside and outside houses, including deposited dust, feathers, and other potential fomites. Viral RNA (vRNA) and infectious viruses were detected in air samples collected from inside and outside but in close proximity to infected houses, with vRNA alone being detected at greater distances (≤10 m) outside. Some dust samples collected outside of the affected houses contained infectious viruses, while feathers from the affected houses, located up to 80 m away, only contained vRNA. Together, these data suggest that airborne particles harboring infectious HPAIV can be translocated short distances (<10 m) through the air, while macroscopic particles containing vRNA might travel further (≤80 m). Therefore, the potential for airborne transmission of clade 2.3.4.4b H5N1 HPAIV between premises is considered low. Other factors, including indirect contact with wild birds and the efficiency of biosecurity, represent greater importance in disease incursion.
Collapse
Affiliation(s)
- Joe James
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
- WOAH/FAO International Reference Laboratory for Avian Influenza, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| | - Caroline J. Warren
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| | - Dilhani De Silva
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| | - Thomas Lewis
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
- WOAH/FAO International Reference Laboratory for Avian Influenza, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| | - Katherine Grace
- Epidemiology and Risk Policy Advice, Advice Services, Animal and Plant Health Agency (APHA), Woodham Lane, Addlestone KT15 3NB, UK
| | - Scott M. Reid
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| | - Marco Falchieri
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| | - Ian H. Brown
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
- WOAH/FAO International Reference Laboratory for Avian Influenza, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| | - Ashley C. Banyard
- Department of Virology, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
- WOAH/FAO International Reference Laboratory for Avian Influenza, Animal and Plant Health Agency (APHA-Weybridge), Woodham Lane, Addlestone KT15 3NB, UK
| |
Collapse
|
9
|
Gouma PI. How to Build Live-Cell Sensor Microdevices. SENSORS (BASEL, SWITZERLAND) 2023; 23:3886. [PMID: 37112227 PMCID: PMC10144235 DOI: 10.3390/s23083886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 03/30/2023] [Accepted: 04/04/2023] [Indexed: 06/19/2023]
Abstract
There is a lot of discussion on how viruses (such as influenza and SARS-CoV-2) are transmitted in air, potentially from aerosols and respiratory droplets, and thus it is important to monitor the environment for the presence of an active pathogen. Currently, the presence of viruses is being determined using primarily nucleic acid-based detection methods, such as reverse transcription- polymerase chain reaction (RT-PCR) tests. Antigen tests have also been developed for this purpose. However, most nucleic acid and antigen methods fail to discriminate between a viable and a non-viable virus. Therefore, we present an alternative, innovative, and disruptive approach involving a live-cell sensor microdevice that captures the viruses (and bacteria) from the air, becomes infected by them, and emits signals for an early warning of the presence of pathogens. This perspective outlines the processes and components required for living sensors to monitor the presence of pathogens in built environments and highlights the opportunity to use immune sentinels in the cells of normal human skin to produce monitors for indoor air pollutants.
Collapse
Affiliation(s)
- Pelagia-Irene Gouma
- Department of Materials Science and Engineering, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
10
|
Aerosolize this: Generation, collection, and analysis of aerosolized virus in laboratory settings. PLoS Pathog 2023; 19:e1011178. [PMID: 36893118 PMCID: PMC9997909 DOI: 10.1371/journal.ppat.1011178] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/10/2023] Open
|
11
|
Joan TV, Kristiyan SA, Ernest SL, Nuria TP, Herme GB, Josep MB. Efficiency and sensitivity optimization of a protocol to quantify indoor airborne SARS-CoV-2 levels. J Hosp Infect 2022; 130:44-51. [PMID: 36100140 PMCID: PMC9465472 DOI: 10.1016/j.jhin.2022.08.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/24/2022] [Accepted: 08/26/2022] [Indexed: 11/29/2022]
Abstract
Background Development of methodologies to quantify airborne micro-organisms is needed for the prevention and control of infections. It is difficult to conclude which is the most efficient and sensitive strategy to assess airborne SARS-CoV-2 RNA levels due to the disparity of results reported in clinical settings. Aim To improve our previously reported protocol of measuring SARS-CoV-2 RNA levels, which was based on bioaerosol collection with a liquid impinger and RNA quantification with droplet digital polymerase chain reaction (ddPCR). Methods Air samples were collected in COVID-19 patient rooms to assess efficiency and/or sensitivity of different air samplers, liquid collection media, and reverse transcriptases (RT). Findings Mineral oil retains airborne RNA better than does hydrophilic media without impairing integrity. SARS-CoV-2 ORF1ab target was detected in 80% of the air samples using BioSampler with mineral oil. No significant differences in effectiveness were obtained with MD8 sampler equipped with gelatine membrane filters, but the SARS-CoV-2 copies/m3 air obtained with the latter were lower (28.4 ± 6.1 vs 9 ± 1.7). SuperScript II RT allows the detection of a single SARS-CoV-2 genome RNA molecule by ddPCR with high efficiency. This was the only RT that allowed the detection of SARS-CoV-2 N1 target in air samples. Conclusion The collection efficiency and detection sensivity of a protocol to quantify SARS-CoV-2 RNA levels in indoor air has been improved in the present study. Such optimization is important to improve our understanding of the microbiological safety of indoor air.
Collapse
Affiliation(s)
- Truyols-Vives Joan
- Molecular Biology and One Health Research Group (MolONE), Universitat de Les Illes Balears (UIB), Palma, Spain
| | | | - Sala-Llinàs Ernest
- Molecular Biology and One Health Research Group (MolONE), Universitat de Les Illes Balears (UIB), Palma, Spain; Health Research Institute of the Balearic Islands (IdISBa), Balearic Islands, Spain; Department of Pulmonary Medicine, Hospital Universitari Son Espases (HUSE), Balearic Islands, Spain; Biomedical Research Networking Center on Respiratory Diseases (CIBERES), Madrid, Spain
| | - Toledo-Pons Nuria
- Health Research Institute of the Balearic Islands (IdISBa), Balearic Islands, Spain; Department of Pulmonary Medicine, Hospital Universitari Son Espases (HUSE), Balearic Islands, Spain
| | - G Baldoví Herme
- Department of Chemistry, Universitat Politècnica de València (UPV)
| | - Mercader-Barceló Josep
- Molecular Biology and One Health Research Group (MolONE), Universitat de Les Illes Balears (UIB), Palma, Spain; Health Research Institute of the Balearic Islands (IdISBa), Balearic Islands, Spain.
| |
Collapse
|
12
|
Silva PG, Branco PTBS, Soares RRG, Mesquita JR, Sousa SIV. SARS-CoV-2 air sampling: A systematic review on the methodologies for detection and infectivity. INDOOR AIR 2022; 32:e13083. [PMID: 36040285 PMCID: PMC9538005 DOI: 10.1111/ina.13083] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 07/06/2022] [Accepted: 07/08/2022] [Indexed: 06/15/2023]
Abstract
This systematic review aims to present an overview of the current aerosol sampling methods (and equipment) being used to investigate the presence of SARS-CoV-2 in the air, along with the main parameters reported in the studies that are essential to analyze the advantages and disadvantages of each method and perspectives for future research regarding this mode of transmission. A systematic literature review was performed on PubMed/MEDLINE, Web of Science, and Scopus to assess the current air sampling methodologies being applied to SARS-CoV-2. Most of the studies took place in indoor environments and healthcare settings and included air and environmental sampling. The collection mechanisms used were impinger, cyclone, impactor, filters, water-based condensation, and passive sampling. Most of the reviewed studies used RT-PCR to test the presence of SARS-CoV-2 RNA in the collected samples. SARS-CoV-2 RNA was detected with all collection mechanisms. From the studies detecting the presence of SARS-CoV-2 RNA, fourteen assessed infectivity. Five studies detected viable viruses using impactor, water-based condensation, and cyclone collection mechanisms. There is a need for a standardized protocol for sampling SARS-CoV-2 in air, which should also account for other influencing parameters, including air exchange ratio in the room sampled, relative humidity, temperature, and lighting conditions.
Collapse
Affiliation(s)
- Priscilla G Silva
- Laboratory for Integrative and Translational Research in Population Health (ITR), Porto, Portugal
- School of Medicine and Biomedical Sciences (ICBAS), University of Porto, Porto, Portugal
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Porto, Portugal
- ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
- Epidemiology Research Unit (EPI Unit), Institute of Public Health, University of Porto, Porto, Portugal
| | - Pedro T B S Branco
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Porto, Portugal
- ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| | - Ruben R G Soares
- Department of Biochemistry and Biophysics, Science for Life Laboratory, Stockholm University, Solna, Sweden
- Division of Nanobiotechnology, Department of Protein Science, Science for Life Laboratory, KTH Royal Institute of Technology, Solna, Sweden
| | - João R Mesquita
- Laboratory for Integrative and Translational Research in Population Health (ITR), Porto, Portugal
- Epidemiology Research Unit (EPI Unit), Institute of Public Health, University of Porto, Porto, Portugal
| | - Sofia I V Sousa
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology and Energy, Faculty of Engineering, University of Porto, Porto, Portugal
- ALiCE - Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| |
Collapse
|
13
|
Isanovic M, Correa Velez KE, Norman RS. Dispersion of SARS-CoV-2 RNA across a wastewater treatment plant and its workers. WATER AND ENVIRONMENT JOURNAL : THE JOURNAL 2022; 36:WEJ12812. [PMID: 35942195 PMCID: PMC9349956 DOI: 10.1111/wej.12812] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 06/23/2022] [Accepted: 06/25/2022] [Indexed: 05/16/2023]
Abstract
Within urban and suburban sewersheds, SARS-CoV-2 released through faeces is transported through sewage systems into municipal wastewater treatment plants (WWTPs). Studies have shown that viral RNA is detectable in untreated wastewater but not in WWTP effluent. In this study, we investigated treatment steps between the influent and final treated effluent to identify the point at which viral RNA is below detection. Additionally, we examined air surrounding high turbulence treatment steps to test for the presence of SARS-CoV-2 RNA in WWTP-generated bioaerosols. To examine potential worker exposure to SARS-CoV-2, WWTP workers were tested for the presence of viral RNA. The data show that despite high viral RNA concentration in the influent, SARS-CoV-2 RNA concentration decreased significantly (p < 0.02) in the main treatment steps and was below detection in the effluent. Additionally, SARS-CoV-2 RNA was below detection in air samples (n = 42), and the worker rate of infection was not significantly different (p = 0.99) from the rate of infection in the surrounding community. These results suggest that WWTP workers may have minimal exposure to SARS-CoV-2 during routine outdoor work procedures and that the WWTP successfully reduces the amount of viral RNA entering effluent receiving waters, providing a vital public health service to communities.
Collapse
Affiliation(s)
- Mirza Isanovic
- Department of Environmental Health Sciences, Arnold School of Public HealthUniversity of South CarolinaColumbiaSouth CarolinaUSA
| | - Karlen E. Correa Velez
- Department of Environmental Health Sciences, Arnold School of Public HealthUniversity of South CarolinaColumbiaSouth CarolinaUSA
| | - R. Sean Norman
- Department of Environmental Health Sciences, Arnold School of Public HealthUniversity of South CarolinaColumbiaSouth CarolinaUSA
| |
Collapse
|
14
|
Terrier O, Si-Tahar M, Ducatez M, Chevalier C, Pizzorno A, Le Goffic R, Crépin T, Simon G, Naffakh N. Influenza viruses and coronaviruses: Knowns, unknowns, and common research challenges. PLoS Pathog 2021; 17:e1010106. [PMID: 34969061 PMCID: PMC8718010 DOI: 10.1371/journal.ppat.1010106] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
The development of safe and effective vaccines in a record time after the emergence of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is a remarkable achievement, partly based on the experience gained from multiple viral outbreaks in the past decades. However, the Coronavirus Disease 2019 (COVID-19) crisis also revealed weaknesses in the global pandemic response and large gaps that remain in our knowledge of the biology of coronaviruses (CoVs) and influenza viruses, the 2 major respiratory viruses with pandemic potential. Here, we review current knowns and unknowns of influenza viruses and CoVs, and we highlight common research challenges they pose in 3 areas: the mechanisms of viral emergence and adaptation to humans, the physiological and molecular determinants of disease severity, and the development of control strategies. We outline multidisciplinary approaches and technological innovations that need to be harnessed in order to improve preparedeness to the next pandemic.
Collapse
Affiliation(s)
- Olivier Terrier
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- CIRI, Centre International de Recherche en Infectiologie (Team VirPath), Inserm U1111, Université Claude Bernard Lyon 1, CNRS UMR5308, ENS de Lyon, Lyon, France
| | - Mustapha Si-Tahar
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- Inserm U1100, Research Center for Respiratory Diseases (CEPR), Université de Tours, Tours, France
| | - Mariette Ducatez
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- IHAP, UMR1225, Université de Toulouse, ENVT, INRAE, Toulouse, France
| | - Christophe Chevalier
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- Université Paris-Saclay, UVSQ, INRAE, VIM, Equipe Virus Influenza, Jouy-en-Josas, France
| | - Andrés Pizzorno
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- CIRI, Centre International de Recherche en Infectiologie (Team VirPath), Inserm U1111, Université Claude Bernard Lyon 1, CNRS UMR5308, ENS de Lyon, Lyon, France
| | - Ronan Le Goffic
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- Université Paris-Saclay, UVSQ, INRAE, VIM, Equipe Virus Influenza, Jouy-en-Josas, France
| | - Thibaut Crépin
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- Institut de Biologie Structurale (IBS), Université Grenoble Alpes, CEA, CNRS, Grenoble, France
| | - Gaëlle Simon
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- Swine Virology Immunology Unit, Ploufragan-Plouzané-Niort Laboratory, ANSES, Ploufragan, France
| | - Nadia Naffakh
- CNRS GDR2073 ResaFlu, Groupement de Recherche sur les Virus Influenza, France
- RNA Biology and Influenza Virus Unit, Institut Pasteur, CNRS UMR3569, Université de Paris, Paris, France
| |
Collapse
|
15
|
Kim K, Narayanan J, Sen A, Chellam S. Virus Removal and Inactivation Mechanisms during Iron Electrocoagulation: Capsid and Genome Damages and Electro-Fenton Reactions. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:13198-13208. [PMID: 34546747 DOI: 10.1021/acs.est.0c04438] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Virus destabilization and inactivation are critical considerations in providing safe drinking water. We demonstrate that iron electrocoagulation simultaneously removed (via sweep flocculation) and inactivated a non-enveloped virus surrogate (MS2 bacteriophage) under slightly acidic conditions, resulting in highly effective virus control (e.g., 5-logs at 20 mg Fe/L and pH 6.4 in 30 min). Electrocoagulation simultaneously generated H2O2 and Fe(II) that can potentially trigger electro-Fenton reactions to produce reactive oxygen species such as •OH and high valent oxoiron(IV) that are capable of inactivating viruses. To date, viral attenuation during water treatment has been largely probed by evaluating infective virions (as plaque forming units) or genomic damage (via the quantitative polymerase chain reaction). In addition to these existing means of assessing virus attenuation, a novel technique of correlating transmission electron micrographs of electrocoagulated MS2 with their computationally altered three-dimensional electron density maps was developed to provide direct visual evidence of capsid morphological damages during electrocoagulation. The majority of coliphages lost at least 10-60% of the capsid protein missing a minimum of one of the 5-fold and two of 3- and 2-fold regions upon electrocoagulation, revealing substantial localized capsid deformation. Attenuated total reflectance-Fourier transform infrared spectroscopy revealed potential oxidation of viral coat proteins and modification of their secondary structures that were attributed to reactive oxygen species. Iron electrocoagulation simultaneously disinfects and coagulates non-enveloped viruses (unlike conventional coagulation), adding to the robustness of multiple barriers necessary for public health protection and appears to be a promising technology for small-scale distributed water treatment.
Collapse
Affiliation(s)
- Kyungho Kim
- Department of Civil & Environmental Engineering, Texas A&M University, College Station, Texas 77843-3136, United States
| | - Jothikumar Narayanan
- Centers for Disease Control and Prevention, National Center for Emerging and Zoonotic Infectious Diseases, Atlanta, Georgia 30329, United States
| | - Anindito Sen
- Microscopy and Imaging Center, Texas A&M University, College Station, Texas 77843-2257, United States
| | - Shankararaman Chellam
- Department of Civil & Environmental Engineering, Texas A&M University, College Station, Texas 77843-3136, United States
- Department of Chemical Engineering, Texas A&M University, College Station, Texas 77843-3122, United States
| |
Collapse
|